Loading...
HomeMy WebLinkAbout51536-Z �OF 500lyO!° Town of Southold * * P.O. Box 1179 0 53095 Main Rd U k Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46024 Date: 03/06/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1865 Highland Rd CutchoQue, NY 11935 See/Block/Lot: 102.-8-6 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11/04/2024 Pursuant to which Building Permit No. 51536 and dated: 01/10/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to: Michael Kimmelman , Debra Kimmelman Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51536 2/24/2025 PLUMBERS CERTIFICATION: Authorized vignature �o��oFga�,yolo TOWN OF SOUTHOLD BUILDING DEPARTMENT ' e TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51536 Date: 01/10/2025 Permission is hereby granted to: Michael Kimmelman 1865 Highland Rd Cutchogue, NY 11935 To: Install roof mounted solar panels to an existing single-family dwelling as applied for.Additional certification may be required. Premises Located at: 1865 Highland Rd, Cutchogue, NY 11935 SCTM# 102.-8-6 Pursuant to application dated 11/04/2024 and approved by the Building Inspector. To expire on 01/10/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 ELECTRIC -Residential $125.00 Total $325.00 Building Inspector _____— OF SOUI�,oI � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q �► • �o JameshCc-southoldtownny.gov Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Michael Kimmelman Address: 1865 Highland Road city,Cutchouge st: New York zip: 11935 Building Permit#: 51536 Section: 102 Block: 8 Lot: 6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: Element Energy LLC. Electrician: Jamie Minnick License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump 11 Other Equipment: 10.2 kw roof mountied system with 24 panels [JKM425N-54HL4-B] 24 microinverters [ENPHASE IQ8MC-72-M-us]1 enhase combiner panel with back feed breaker Notes: SOLAR ENERGY SYSTEM Inspector Signature: Date: February 24, 2025 V 1865 highland rd *pF SOUIyo TOWN OF SOUTHOLD, BUILDING DEPT. °y o►�Ni� 631-765-1802 INSPECT110N [ - ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ .] I SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL *IAX- [ ] -FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT-CONSTRUCTION [ ] :FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]. PRE C/O [ ] RENTAL c'o REMARKS. 0 IL 'ae DATE INSPECTOR ------ - - - --- - --- - - - oFso�ry 1 � %� G �, 141 . # T WN Q O O SOUTH L BU ING�EPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] .FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR - - - GGG r i Page 1 of 1 Southold townP� Current, 02/03/2025 �epa�O`d Renewables � �ti� �o��o Engineering JoW Subject: Structural Observation Report Job: Kimmelman, Michael - 1865 Highland Rd Project Address: 1865 Highland Road, Cutchogue, NY, 11935 Attn.: To Whom It May Concern After inspecting the installation of the above referenced project, it is the opinion of Current Renewables Engineering to certify that to the best of our knowledge, belief, and professional judgment the PV installation is in conformance with the Structural Calculations. Verification of all relevant installation methods and materials was provided by Element Energy LLC. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. oF NEW yo � I' Current Renewables Engineering Inc. *� P�aSH AN Professional Engineer info@currentrenewableseng.com 101084 Exp.01/31/2028 Signed on:02/03/2025 i i i 3600 Lime St Bldg 2,Ste#224, Riverside,CA 92507 (951)203-5933 info@currentrenewableseng.com MELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) - --- ----- - 1,� ----------------------------------- -- ------ -- - G cn FOUNDATION (2ND) 0 a ROUGH FRAMING& a PLUMBING - - . 1 r r� INSULATION PER N.Y. STATE ENERGY CODE - FINAL; --_-- ADDITIONAL COMMENTS _ - � z S M ---- _ � E7 - c% � ro -- — Qs -- y -- — 0 O -- b SUFFotX�oG� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 lei�o! ao� Telephone(631)765-1802 Fax(631)765-9502 https://www.sciutholdtownny.gov Date Received APPLICATION FOR BUILDING PERMIT 0 �'T 1 F For Office Use Only � PERMIT NO. v Building Inspector. 1-Al) arid'�`forms must be filletl aut in their',"entirety Incomplete ,` �� � °ra�b®ld, applications will,not be'acceptedm Where the Apphcant,is not the owner,an -Tow "0Wnees:Authorizati6n form(Page 2)s ail be completed Date: 10 'OWNER(S),OF PROPERTY !- Name: !''/fin 11,01a .1 K' . me 1,ni- SCTM# 1000- ! 0 pC (0 Project Address: L S G0 5 H )� �.Ic� (/` t .C..h � �i' I �-- 3 Phone#: j Li�"� Email:. yn Mailing Address: `SG� J l 9 kr CUr oyv) CONTACT'PERSON Name: . Mailing Address: Phone_#:..�..�_..�_.."-cJ 9 .-77 Email: DESIGN`PROFESSIONAL IN:F,ORMATION Name: 4 14- Mailing Address: Phone#: Email: CONTRACTOR INFORMATION Name. Mailing Address: t Phone#: ( ? q Email DESCRIPTION OF PROPOSED CONSTRUCTION t' El New Structure ❑Addition ❑Alte ation ❑Repair ❑Demolition Estimated Cost of Project: y C Jar )P v cSU� $`Other Will the lot be re-graded? ❑Ye _U`No Will excess fill be removed from premises? ❑Yes IV0 1 PROPERTY .INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes,-ENo IF YES, PROVIDE A COPY. D;Check Box After Reading "Tne owner/contractor/design professional is responsible,for all.dramage;and storm,'i rater issues asp ovided by -•Chapter,,236 of the Town Code:APPLICATION I5 HEREBY MADE to.the'Building Department for'the issuance of a-Building Permit pursuant-to the Building zone Ordinance of the•Town of Southold,Suffolk,-County;•New york and other applicable Laws,Ordinances or Regulations for the const�uMion of builds'!g ;' 1. additions,alterations,orfti;ieinoval or demolition.as hereiri described The applicant agrees to;complywith all applicable;laws,, r4nances,,building code, h'ousmg code and regulations and to"admit authorized.iiispectors on;premises and in buildmg(s)'for necessary,inspections.:False statements made herein are punishable as a Class A,misdemeanor.pursuant to Section 210e4S of the New York State Penal Law ' Application Submitted By(print name):h� � � -2Authorized Agent El Owner Signature of Applicant: �kluALm Date: ` 0 &Lj /Z 7 STATE OF NEW YORK) SS: COUNTYOF�bI brnal;ou being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)heisthe C/� 1�� ►� (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 0), , 2034 LOUIS J ROMEO Noty Public Notary Public,State of New York No.01 R06314813 Qualified in Suffolk County PROPERTY OWNER AUTHORIZATION Commission Expires November 17,202- (Where the applicant is not the owner) I, V� 1.6 � residing at G(✓ / �CI -C do hereby authorize to apply on my behalf to a Town of Southold Bu' ng Department for approval as described herein. l0 -Y12 Own-erts igignature D to LOUIS J ROMEO Notary PuNo.blic Date of N3 wNbrli . Print Owner's Name Qualified in Suffolk County Commission Expires November 17i 20 06 2 g�FFO(,t TOWN OF SOUTHOLD —BUILDING DEPARTMENT �� y2 y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny_gov ;c Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: ; . r >Appticatioris and;forms must be ed out in their.entlrety Incomplete t applications will not be accepted_` Here the Applicant-is not the owner,an � Owner's Author�zetion form(Page 2 hall be completed Date: OWNER(S:)OF PROPERTY Name: /CTM# 1000- Project Address: Phone#: Email: Mailing Address: CONTACT`:PERSON r r '' 1 , Name: Mailing Address: Phone#: Email: DESIGN'PROFESSIONAL INFORMATION r # $ Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATIO Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises? ❑Yes El No 1 stIFF01.q. BUILDING DEPARTMENT- Electrical Inspector Gym TOWN OF SOUTHOLD o x Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 1* a0� Telephone (631) 765-1802 - FAX (631) 765-9502 1 ' iamesh(&-southoldtownny.4ov-seandO-southoldtownny.4ov i APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 0 3o Company Name: EV emen+ - Electrician's Name: Yy�,'' ail rDlrll License No.: . eo g lq^€ Elec. email: Elec. Phone No: 45 t-71 ct.-2993 [91 request an email copy of Certificate of Compliance Elec. Address.: -1 q-7 o ,So 6L-raa- CL J e- Fl cI++ JOB SITE INFORMATION� r,, (All Information Required) /� Name: I r I. I C afj 1<)'On melm L�n Address: o S )'4 h land (1,V+CJ1 0 a UL , N I q 3 Cross Street: Phone No.: L -- L+(¢ b l SJ Bldg.Permit#: 5115 ?j(D email: Pay-m 145 Co e s,C Tax Map District: ' 1000 Section: 10 a. Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): =n S+`,..IV -P I V-S d,-N r-0 0 k- m 0 V' -It"k 50 i A.r °P\/ ray i lc w I f - rnoauks - ) in kb 3-K M u 2-5W S LIN _6 94 - l vwe.r FY) hUC� g Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES N NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES F] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New service[:]Fire Reconnect❑Flood Reconnect[]Service Reconnect❑Underground❑Overhead i # Underground Laterals R 1 2 D H Frame D Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD y = ` Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh�southoldtownny.gov—seandCcr�southoldtownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION(All Information Required) Date: 10 -o i L4 Company Name: E en Electrician's Name: Vn fYd1 n1'11 License No.: Elec. email: Elec. Phone No.- b5 t_17cl_-2c)c13 Z request an email copy of Certificate of Compliance Elec. Address.: -1 o ,Sc,j:_r ek_ e— e i-,t&Kl JOB SITE INFORMATION (All Information Required) Name: I r I I LY )�tr?,� I ✓}� Address: [ � i' h land -C or jus, N 3 Cross Street: Phone No.: I. -- ►-�(P (a 1 S� Bldg.Permit#- S IS -3Le email: Farm a45 G e,Q 5..0 Tax Map District: 1000 Section: j 0 c-. Block: S-1 Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly) 1 l7 �C W (flL`f - rn0J-0-es - J In`<b J K IL1 Ll 2-5tV- 5 qN C-4 - 1)nVe.r En hU(� 1 d flC Square Footage: Circle All That Apply: q 2_/`1_BLS Is job ready for inspection?- YES N NO Rough In ;Final Do you need a Temp Certificate?: YES® NO Issued On Temp Information: (All information required) Service Size❑1 Ph 3 Ph Size: A # Meters Old Meter# ❑New Service Fire ReconnectOFlood ReconnectOService Reconnect ElUnderground DO;verhead # Underground Laterals 1 2 D H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION i PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used. Comments A`C>R®® CEl�TlFICAT E OF LIABILITY INSURANCE DATE(MM7%16"zO�4 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions Or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT ROBERTS.FEDE INSURANCE AGENCY NAME: 23 GREEN STREET,SUITE 102 PHONE _ FAX AIC Na Ext; A/C Nd: - - HUNTINGTON,NY E-MAIL 11743 ADDRESS: ROBERTS. FEDE INSURANCE INSURERS AFFORDING COVERAGE NAIC# INSURED INSURERA:ADMIRAL INSURANCE COMPANY 24856 Element Energy LLC INSURER8,STATE INSURANCE FUND 523930 DBA ELEMENT ENERGY SYSTEMS INSURERC: 7470 SOUND AVENUE INSURERD: MA M 7 62 MATTITUCK, NY 11952 INSURERE: COVERAGES INSURER F CERTIFICATE NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NA EID ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH EXCLUSIONS AND CONDITIONS OF SUCH POLICIES,LIMITS SHOWN MAY HAVE BEEN REDUCE RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, INSR ADDL SUBR D BY PAID CLAIMS. LTR TYPE OF INSURANCE I D POLICY NUMBER POLICY EFF POLICY EXP COMMERCIAL GENERAL LIABILITY MMIDD/YYYY MM/DD/YYYY LIMITS CLAIMS-MADE �OCCUR A X X CA00005380701 7/14/2024 7/14/2025 EACH OCCURRENCE $ 110001000 DAMAGE TORE TED PREMISES Ea occurrence $ 300,000 X IMA389203C MED EXP(Any one person) '$ 5000 INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: 7/19/2024 7/19/2025 PERSONAL&All 1000000 POLICY JECTP"- LOC GENERAL AGGREGATE $ 2,000,000 OTHER: PRODUCTS-COMP/OP AGG $ 1/2 0000 0 0 AUTOMOBILE LIABILITY $ COMBINED GLE ANY AUTO Ea accident SIN LIMIT $ OWNED SCHEDULED BODILY INJURY(Per person) $ AUTOS ONLY AUTOS HIRED NON-OWNED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS ONLY PROPERTY DAMAGE Per accident $ UMBRELLA LIAR $ OCCUR EXCESS LIAR CLAIMS-MADE EACH OCCURRENCE $ DIED RETENTION$ AGGREGATE $ WORKERS COMPENSATION $ AND EMPLOYERS LIABILITY 124494445 PER ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N 7/13/2024 7/13/2025 STATUTE ER B (MandaOFFICEtory in H)EXCLUDED? � N/A E.L.EACH ACCIDENT (Mandatary in NH) $ 1 OOO 000 If yes,describe under E.LDISEASE-EAEMPLOYE DESCRIPTION OF OPERATIONS below $ NY State DBL E.L.DISEASE-POLICY LIMIT $ DBLss7527 1/01/2024 12/31/2025 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED- CERTIFICATE HOLDER CANCELLATION Town of Southold EAUTHORIZED LD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold, NY 11971 RDANCE WITH THE POLICY PROVISIONS. �REPRESENTATIVE ,e+ S. Fedej CORD 25(2016103) The ACORD name and logo are registered marks of ACORD ACORD CORPORATION. All rights reserved. YORI< Workers'E om CERTIFICATE OF INSURANCE COVERAGE STAT Cpensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. Fj C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2024 By ,✓ (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Leston Welsh,Chief Executive Officer IMPORTANT. If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) IIJIIIIP!'!'��° °n�����11°11°0��11°��18°°�IIIIIII NYS I F New York State Insurance Fund PO Box 66699,Albany,NY 12206 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) ^A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER [—CERTIFICATE NUMBER POLICY PERIOD DATE 124494 962287 07/13/2024 TO 07/13/2025 7/11/2094 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COM/CERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 743799006 r APPROVED AS NOTED DATE oo I6 2.5 B.P. �iJ�3w COMPLY WITH ALL CODES OF FE 0 ., BY NEW YORK STATE&TOWN CODES NOTIFY BUILDING'DEPARTMENT AT NQ REQUIRED AND CONDITIONS OF 631-765-1802 8AM TO 4PM FOR THE mzm FOLLOWING'INSPECTIONS: FOUNDATION-TWO REQUIRED FOR POURED CONCRETE KYADFC ROUGH-.FRAMING&PLUMBING � INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL iMEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS �isconv-W4 MU5+ bc local 045i CL a > l abded and r e U I Y (�CC�$gj�p�, ELECTRICAL � INSPECTION REQUIRED Additional Certification May Be Required. aunt- ELEMENT ENERGY LLC. EZSYSs. 7470 SOUND AVENUE, MATTITUCK, NEW YORK, 11952 I DATE: 12/28/2024 MICHAEL KIMMELMAN Job Address: 1865 HIGHLAND RD, CUTCHOGUE, NY 11935 i REV-A Plan revisions noted below. 1. Please revise your design criteria to reflect 130 mph wind speed as required per 2020 residential code of NYS figure R301.2(5)A. -Wind speed has been updated on the cover sheet(PV-1.0) I Page 1 of 2 Current' 10/29/2024 ReneWables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Kimmelman, Michael - 1865 Highland Rd Project Address: 1865 Highland Road, Cutchogue, NY, 11935 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit'team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 30.0 psf Min Snow Roof: N/A 6cp:09/30/2025 A. ��OF NEW y Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com ti 106793 A F Np� Signed on:10/29/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 38 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 20 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com ROOF MOUNT SOLAR PERMIT PACKAGE pfNEW,, MICHAEL KIMMELMAN * llv�k`SNZAHo,�o,�* 10.200 KW DC GRID TIED PHOTOVOLTAIC C� r W O OLTAIC SYSTEM ,o;8 ciz 1865 HIGHLAND RD., CUTCHOGUE, NY 11935 .iv - w"P .01/31/2028 e 1Signed on:12272024 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES Town of 0pa►>Fn, THESE ESEIRTIONBY 1ROTE :C USLA11EIT TO O COOTIONGNT THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC O d ANY FORM Is EXPRESSLY FORBIDDEN WITHOUT 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY PRIOR WRITTEN APPROVAL FROM CURRENT �j POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: RENEWABLES ENGINEERING INC. SOLAR PHOTOVOLTAIC INSTALLATION 76 2020 BUILDING CODE OF NEW YORK STATE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES Y 2020 RESIDENTIAL CODE OF NEW YORK STATE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED Current 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 1 2020 EXISTING BUILDING CODE OF NEW YORK STATE UNDERSIGNED RenewableS t s 1 r 2020 FIRE CODE OF NEW YORK STATE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND Engineering _ 2020 PLUMBING CODE OF NEW YORK STATE UL1703 ' 20 MECHANICAL CODE NEW YORK STATE 2017 NEW YORK STATE ELECTRICAL CODE 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT CURRENT RENEWABLES ENGINEERING INC. 17 SUCH AS GEO CEL 2300 CLEAR SEALANT 3600 Lime Street.Bldg z Riverside.CA 92501 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL Email:Pro(ects@creng solar t We6slte vtww.creng.co AHJ TOWN OF SOUTHOLD JURISDICTION AND THE UTILITY IS OBTAINED PHONE:gs1-z1sb354 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, CONTRACTOR INFO MECHANICAL,OR BUILDING ROOF VENTS 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT LEGEND IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE IIIIEN UTILITY METER PRODUCTION METER MANUFACTURER'S INSTALLATION INSTRUCTIONS A 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA Cc SYS.R SP MAIN SERVICE PANEL INv INVERTER REGULATIONS BUILDING INFORMATION 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" ELEMENT ENERGY LLC. C❑ COMBINER ® 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NYSEC. 747DSOUNDAVENUEMATTITUCK uE+ SUB PANEL NEWYORK 11952 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PH(63V"97993 syswm 1 STORY HOUSE SINGLE FAMILY RESIDENCE MODULE L® BACKUP LOAD PANEL GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. S-ce-M2-52689 Ucance-ME-52689 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. (MASTER ELECTRICIAN) 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. Licence-HI-67461 ROOF OBSTRUCTIONS IQ IQ CONTROLLER 2 (SUFFOLK HOME IMPROVEMENT) CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER . 36"ACCESS PATHWAYS THE NYSEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS MICHAEL KIMMELMAN EA-1 BATTERY AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. APN : 1000102000800000000 18"ACCESS PATHWAYS 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8'. QH Q.HOME HUB ABOVE ROOF SURFACE. 1865 HIGHLAND H ROOF ACCESS POINT 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL CUTCHOGUE NY 11935 SHEET INDEX AC ESS DISCONNECT BE RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS. AHJ TOWN OFSOUTHOLD PV-1.0 COVER PAGE BE MAIN BREAKER WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS ENCLOSURE LC 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,LOAD CENTER THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT LONG ISLAND POWER AUTHORITY PV-2.0 SITE PLAN AUTOMATIC TRANSFER UTILITY (LIPA) TS SWITCH SEPTIC TANK STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE PV SUMMARY PV 2.1 ROOF PLAN TO THE PURPOSE INTENDED: SYSTEM SIZE -_-- --- -- -PV 3.0 STRUCTURAL OP PERMANENT ANCHOR SSS LEACH LINES (KWDC) STC 425 X 24 = 0.200 PTC 398.1 X 24= .554 �- -- - WIND SP=CATEGORY : SYSTEM SIZE PV-4.0 ELECTRICAL 3LD PROPANE TANK (KWAC) 7.68 g240 - TEMPORARY ANCHOR SNOW L JINKO SOLAR PV-4.1 ELECTRICAL SLID Q WELL MODULES 24 JKM425N-54HL4$ -- -- - - IL INSTALLER LADDER O EXPOSU MICROINVERTER 24 NPHACs-72-M-US PV-4.2 ELECTRICAL PHOTOS - - Z POWER LINES PV-5.0 BOM S❑ STUB-OUT NO LADDER ACCESS PV-6.0SIGNAGE & PLACARD ® 0 (STEEP GRADE -_ _ SKYLIGHT OR GROUND LEVEL PV-7.0 SPECS+ OBSTRUCTIONS) - RESTRICTED ACCESS Rev Description Date As GAS SHUT OFF - - - - - - ---- -- - 0 INITIAL DESIGN 11292024 I - CONDUIT A UPDATED DESIGN 1228/2024 Hzo WATER SHUT OFF e aJUNCTION BOX 0SERVICE DROP PROJECT# NA DATE DRAWN 12/28/2024 E AC DISCONNECT RAIL DRAWN BY ER RAFTER SHEET# PV-1.0 ATTACHMENT TITLE - - - COVER PAGE R324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND SEPARATE ROOF PLANES, t�OF NEW y FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. ��p'5N ZA,yo�F�.p� AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM r- 36INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SP MAIN SERVICE PANEL ?5 SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING y THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE HIGHLAND R D C❑ COMBINER ��`D 101084 OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS A ACCESSING THE ROORPATHWAYS SHALL BE LOCATED IN AREAS ❑ MODULE ,ONP WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT. ROOF OBSTRUCTIONS Exp.01/31/2028 R324.6.2 SETBACK AT RIDGE: . 36"ACCESS PATHWAYS Signed on 12/272024 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A ROOF LINE ROOF OBSTRUCTION 0 18"ACCESS PATHWAYS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT HORIZONTAL RIDGE. PROPERTY LINE PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 ROOF ACCESS POINT PRIOR WRITTEN APPROVAL FROM CURRENT PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A I RENEWABLE$ENGINEERING INC. 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A 1851-51r HORIZONTAL RIDGE. (— ----- -----� 1� R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS I ti• C Jrrent AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED `` `J THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE jy AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE • , Engineerlr9 PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. "z-y'• ' A pl_nrl I CURR Lime RENEWABLES ENGINEERING INC. Y O' �. ` ' J 3600 e Street,B vnvw.ldg 2 Riverside.CA 92501 NOTES: ma 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL • ! Emil:Projec s@creng.solar •• •^!y' Website: creng.co SITE CONDITION AND MEASUREMENTS. ENLARGED PHONE:951-215l354 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED � '+ :';•.,. . � CONTRACTOR INFO INTO THE 2017 NYSEC AND UL STANDARD 1741. VIEW s 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. uM MSP ___ i r •. ROOF ACCESS POINT ----F---- 651-611 - J mum I ® ® 65' Ec SYS� I FENCE I.I.C.ELEMENT ENERGY 7470 SOUND AVENUE.MATTITUCK, r � NEW YORK 11952 PH:(63O 779 7993 FENCE I services@e2sYs.com ! Licence-ME-52689 1 r O 1 (MASTER Licence- ELECTRICIAN)1 Q r (SUFFOLK HOME IMPROVEMENT) N 1 MICHAEL KIMMELMAN 1 r ROOF ACCESS POINT I - 1865 HIGHLAND RD, 1 CUTCHOGUE NY 11935 r r- I AHJ TOWN OFSOUTHOLD r t• / LONG ISLAND POWER AUTHORITY Ij UTILITY (LIPA) 121 1-3n r PV SUMMARY E ' SYSTEM SIZE STC 425 X 24 =10.200 SHED r KWDc) 1 PTC 396.1 X 24 = .554 r SYSTEM SIZE 768 @240 r (KWAC) E PROPERTY LINE MODULES 24 JINKO) AR M42550N 54HL4-B r 1 r MICROINVERTER 24 ENPHASE 1 � IQBMC-72-M-US I i i I i 1 1 I ---- r Rev Description Date 0 INITIAL DESIGN 1 112 9/2 0 24 185r-311 I A UPDATED DESIGN 12/28/2024 B P ROJECTNA 12/28/2024 E.R TE PLAN PV-2.0 TITLE SCALE: 1/32" = 11-011 SITE PLAN ARRAY AREA STRUCTURAL NOTES : LEGEND ROOF TOTAL 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF FRAMING �OF NEW ARRAY ROOF '� �' ROOF ROOF AZIMUTH #OF AREA AREA AREA AREA SUPPORTING THE PROPOSED PV INSTALLATION ONLY. '�� 5H ZAN O,p TILT MODULES COVERED BY COVERED BY uM UTILITY METER !�* Defy (Sq.Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) 2.THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS MUST FOLLOW MANUFACTURER GUIDELINES sP MAIN SERVICE PANEL #1 38° 222° a sa.o8 z127 3.95 AND REQUIREMENTS. ' #2 20° 222° 8 168.16 2127 7.91 23.72 c COMBINER 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. �? #3 1 38° 1 222° 1 12 1 252.24 1 2127 11.86 5. PRIOR TO COMMENCEMENT OF WORK,THE SOLAR INSTALLER SHALL VERIFY THE ROOF FRAMING INFO MODULE Fop 101o84 �2 BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE ❑ R FE IONP VERIFICATION AND FOLLOWING:2x8 RAFTERS @ 16" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL ROOF OBSTRUCTIONS n OR LESS THAN 14 FT. - 36"ACCESS PATHWAYS Exp.01/31/2028 Signed on:12272024 HIGHLAND R D 18"ACCESS PATHWAYS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN _ RAIL ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RAFTER RENEWABLES ENGINEERING INC ATTACHMENT Current =� Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 Emil.Projects@creng.solar Websde:vrvw reng.co PHONE:951-215-6354 CONTRACTORINFO FM MSP CZSYSlV ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK 11952 PH:(630 779 7993 service Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 SUFF LK HOME IMPROVEMENT) I I I I I I I I I I ( MICHAEL KIMMELMAN 1865 HIGHLAND RD, CUTCHOGUE NY 11935 AHJ TOWN OF SOUTHOLD II I I I I I I I I I I I LONG ISLAND POWER AUTHORITY O UTILITY (LIPA) PV SUMMARY SYSTEM SIZE (KWDC) - STC 425 X 24=10.200 PTC 39B.1 X 24=9.554 1 2 (K WAC) _ - SYSTEM SIZE _ 758 @240 11KO SOLAR N (N)24 JINKO SOLAR 1KM425N-54HL4-B MODULES P4 1 KM425N-54HL4-B MICROINVERTER P4 EN PHASE IQ8MC-72-M-US Rev Description Date 0 INITIAL DESIGN 11/29/2024 A UPDATED DESIGN 12/28/2024 B PROJECT# NA DATE DRAWN 12/28/2024 DRAWN BY E.R ROOF PLAN SHEET PV-2 2 TITLE SCALE: 1/8" = 11-O" ROOF PLAN TABLE 1 TABLE 2 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX Of NEWy O NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG htQ�pSN ZA ��� p��� sz ATTACHMENT IRONRIDGE HUG * p 6 O ROOF 1 38' COMP SHINGLE RAFTER 2"X8" 16" 64" 24" s3 RAIL IRONRIDGE AIRE A2 RAIL ROOF 2 20o COMP SHINGLE RAFTER 2"X8" 16" 64" 24" ti ROOF 3 380 COMP SHINGLE RAFTER 2"X8" 16" 64" 24" OpR IONP� Exp.O1/31/2O28 Signed on:1227/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. � Current ink Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 Email:Projects@creng.solar MODULEWebsi[e:www.creng.co PHONE:951 215-6354 CONTRACTORINFO S3 S2 mum ROOF TABLE : PENETRATION CZSYS�GUIDE FOR INSTALL ELEMENT ENERGY LLCAVENUE . TWO OR MORE ROWS OF PANELS 747060 ND NEW O K11952mTUCK, PH:(631)779 7993 ices@e2sys.com Licence-ME-52689 .S 1 2.5"MIN.EMBED. (MA cent.-.1-6ELECTRICIAN)1 LLM (SUFFOLK HOME IMPROVEMENT) c. MICHAEL KIMMELMAN 1865 HIGHLAND RD, CUTCHOGUE NY 11935 (2)-#14 X 3" SELF DRILLING I ( I I I I I I I I I I I S AHJ TOWN OF SOUTHOLD STRUCTURAL SCREWS TO EXISTING STRUCTURE I I I I I I I I I I I I I I I I I I I I UTILITY LONG ISLAND POWER AUTHORITY ENLARGED VIEW (L1PA) PV SUMMARY STACKED STAGGERED FULLY STAGGERED SYSTEM SIZE 3rr (KWDC) STC 425 X 24 =10200 "/1 V SYSTEM SIZE PTC 396.1 X 24 = 557 6q MqX ONE ROW OF PANELS (KWAC) 7.68 (P240 MODULE MODULES 24 KM425N 54HL4-8 MICROINVERTER P4 ENPHASE IQ8MC-72-M-U5 I I I I I I I I I I SEE ENLARGED VIEW � � FULLY STAGGERED STACKED/STAGGERED Rev Description Date S1 ROOF 0 INITIAL DESIGN 11/29/2024 A UPDATED DESIGN 12/28/2024 �. B PROJECT# NA DATE DRAWN 12/28/2024 ATTACHMENT DETAILS DRAWN BY ER SHEET# PV-3.O TITLE STRUCTURAL BACKFEED BREAKER SIZING OF NS MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST C3 L Af, METER NUMBER-98278258 K` cCi �¢ 31.92 X 1.25 = 39.90AMPS 40A BREAKER-OK V (� S.NO. ITEMS DESCRIPTION QTY. * � � SEE 705.12 OF 2017 NYSEC JINKO SOLAR UTILITY-9629001553 r— c4 g 200 X 1.20 = 240 1 PV MODULE JKM425N-54HL4-B 24 j— ` tci 240 - 200 = 40A ALLOWABLE BACKFEED 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 24 ENPHASE IQ COMBINER L O �$748% 3 COMBINER 5/5C 1 O� 1a�� (E)UTILITY METER TO UTILITY rSSrOF GRID ealed 02jan2025 mike@h2dc.com 12DC PLLC NY CoA#:PB-082933 3 NOTE:TWO QUAD BREAKER NEEDED TANDEM TO ELECTRICAL ONLY MAKE A ROOM FOR POI IN MSP. RE CONSTRUCTION DRAWING SET (N) ENPHASE COMBINER BOX THESE DRAWINGS ARE SUBJECT TO COPYRIGHT U PROTECTION BY US LAW.REPRODUCTION IN (E)200A RATED ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT MAIN SERVICE PANEL PRIOR WRITTEN APPROVAL FROM CURRENT CELL WIRE LESS 1PH,120/240V 60HZ RENEWABLES ENGINEERING INC. MODEM IT COMMS Curren, Rqq !t1 (E)200A/2P Erglnee'Ir g A MAIN BREAKERN)15A (N)40A/2P PV (BOTTOM FED) CURRENT RENEWABLES ENGINEERING INC. /1\ 7 —1 BREAKER 3600 Lime Emil. Pro)ec 2 Riverside,CA 92501 •/� Email:ProJects@crengsolar l Webske:vmw eng.co I 1 BRANCH OF 12 PHONE'. 951-215fi354 PV MODULE Nt (N)20A/1� l •�• CONTRACTOR INFO / , ' I • (N)20A./ I • EZSYS 2 BRANCH L 12 l L -------_ L --Lt 7470 SOUND AVENELEMENT EUE,MATfITUCK, GY LUC. PV MODULE!, r--- ---J -----� NEWYORK 71952 PH:(630 779 7993 J sereices@e2sys.com Lice nce-ME-526a9 9L--------------- MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) B MICHAEL KIMMELMAN (E)GROUNDING ELECTRODE — 1865 HIGHLAND RD, CONDUCTOR #6 BARE COPPER MODULE JINKO SOLAR CUTCHOGUE NY11935 MANUFACTURER AHJ TOWN OF SOUTHOLD MODULE MODEL JKM425N-54HL4-B UTILITY LONG ISLAND POWER AUTHORITY (LIPA) MODULE(W) 425 PV SUMMARY MODULE PTC(W) 398.1 (KWDCM slzE STC 425 X 24[11.2013 10200 398., X 24 9.554 MODULE Isc(A) 13.58 SYSTEM SIZE PTC MODULE Voc(V) 38.95 NOTE: (KWAC) 768 @240 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS MODULES 24 11NKO SOLAR MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ENPHASE saHLa B MODULE Vmp(V) 32.37 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH MICROINVERTER 24 ENPHASE 72-M-US PROPER JUNCTION BOX AT EACH END PER 690.31A NOTE:EGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE WIRE CALCULATION STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE CURRENT FACTOR FOR ADJUSTED CURRENT Rev Description Date CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION 0 INITIAL DESIGN 11i29(2024 TAG QTY. SIZE(AWG) DESCRIPTION SIZE&TYPE AMPACITY RATING (°C) APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO A UPDATED DESIGN 12/28/2024 310.15(B)(16) CONDUCTORS 31015(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS B . IN RACEWAY 310.150)(3)(a) IN RACEWAY PROJECT# INA DATE DRAWN 1212&2024 SKU:Q-12-RAW-300, THHN DRAWN BY ER A 2 12 N/A FREE AIR 30 90° 15.96 0.96 1 28.80 19.95 1 8 THWN-2 BARE COPPER-(GROUND) SHEET# PV40 3 g THWN-2 COPPER-(L1,L2) TITLE B 3/4" PVC 40 90° 15.96 0.96 1 38.40 19.95 ELECTRICAL KID 1 10 THWN-2 COPPER-(GROUND) BACKFEED BREAKER SIZING OF NE' g MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST 'lP�-�EL lye yop 31.92 1XI 1.25 1 = 139.90AMPS 140A BREAKER-OK * V CG S.NO. ITEMS DESCRIPTION QTY. SEE 705.12 OF 2017 NYSEC JINKO SOLAR METER NUMBER-98278258 Fn 200 X 1.20 = 240 1 PV MODULE JKM425N-54HL4-B 24 UTILITY-9629001553 I- 240 200 1 = 140A ALLOWABLE BACKFEED 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 24 Nth` ENPHASE IQ COMBINER Z488 3 COMBINER 5/5C 1 1 (E)UTILITY METER TO UTILITY O rSslot, GRID 3ealed 02jan2025 mike@h2dc.com 2DC PLLC NY CoA#:PB-082933 3 NOTE:TWO QUAD BREAKER NEEDED TANDEM TO ELECTRICAL ONLY MAKE A ROOM FOR POI IN MSP. RE CONSTRUCTION DRAWING SET (N) ENPHASE THESE DRAWINGS E SUBJECT TO COMBINER BOX PROTECTION BY US LAW REPRODUCTION INT (E)200A RATED ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT MAIN SERVICE PANEL RENEWABLES ENGINEERING INC. t�ZMS LESS 1PH,120/240V 60HZ Curer: 1ft( (E)200A/2P Engineer A /yam MAIN BREAKER `Z (N)15A_, `- /2P PV (BOTTOM FED) CURRENT RENEWABLES ENGINEERING INC. (N)40A 3600 Lime Stre LBIdg 2 Riverside,CA 92501 BREAKER Email Projects@creng.solar •�iWebsi[e'.vrww reng.co • • • PHONE: 951-215{i354 1 BRANCH OF 12 •�• CONTRACTOR INFO PV MODULE N •�• • (N)20A/1\ • cc) a • (N)20A�/I�• ��• mum ��\\ •�. . . CZ SYSs 2 BRANCH OF 12 • ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, PV MODULE <N� NEW PORK iN52 PH:(631)779 7993 ces@e2sys.com xLi ence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) B MICHAEL KIMMELMAN NOTES APPENDIX(AS APPLICABLE FOR TO BE BUILT DRAWING SETS):(A)TOTAL AC VOLTAGE DROP NOT TO EXCEED 2%TO (E)GROUNDING ELECTRODE _ 1865 HIGHLAND RD, INTERCONNECTION,<3%FROM INVERTER(S)TO UTILITY TRANSFORMER.(B)ALL CONNECTORS 75C RATED.(C)ALL CONDUCTORS CONDUCTOR #6 BARE COPPER CUTCHOGU E NY 11935 MODULE JINKO SOLAR COPPER,UNLESS OTHERWISE NOTED.(D)OUTDOOR EQUIPMENT NEMA3R.(E)ALL CONDUCTORS MUST BE PROTECTED FROM MANUFACTURER ACCESS BY A FENCE OR SUITABLE COVER,OR OUT OF REACH.(F)PROPERTY LINES,BOUNDARIES AND ALL OTHER EXTERIOR AHJ TOWN OF SOUTHOLD MEASUREMENTS ARE FOR REFERENCE ONLY,AND MUST BE VERIFIED BY A LICENSED SURVEYOR OR CIVIL ENGINEER. (G)NO PVC ALLOWED ON ROOF OR IN ATTIC. (H)MC4 CONNECTORS MAY NOT BE JOINED WITH'MC4 COMPATIBLE'CONNECTORS.(1)TAP LONG ISLAND POWER AUTHORITY MODULE MODEL JKM425N-54HL4-B CONNECTIONS IN PANEL MUST NOT VIOLATE CONDITIONS OF ACCEPTABILITY FROM PANEL MANUFACTURER'S NRTL LISTING,OR UTILITY (LIPA) FIELD LABEL REQUIRED.(J)PV WIRES MAY NOT BE LAID DIRECTLY ON ROOF. (K)TY WRAPS FOR WIRE MANAGEMENT MUST BE STRUCTURAL(S21)UL APPROVED,OR EQUAL.(L)DRAWINGS ARE DIAGRAMMATIC AND INDICATE GE-NERAL ARRANGEMENT OF PV SUMMARY MODULE(W) 42 SYSTEMS AND WORK.-CONDUIT ROUTING,WHEN INDICATED,DOES NOT SHOW ALL OFFSETBS,DROPS,AND RISES OF RUNS.(M) SYSTEM SIZE 5 STC azs x 2a 10.zoo MODULE PTC(W) 398.1 BURIED CONDUITS UNDER AREAS SUBJECT TO VEHICLE TRAFFIC REQUIRE MIN 24"COVER. (N)NM-B OR PAPER INSULATED (KWDC) = CONDUCTORS MAY NOT BE USED EXTERIOR. (0)THE DEVELOPER IS REQUIRED TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE PTC 398.1 x 2a =9.554 MODULE Isc(A) 13.58 FROM THE UTILITY,AND MAY NOT RELY S-OLELY ON EXISTING BREAKER SIZES.(P)CONNECTING TO UTILITY EQUIPMENT SYSTEM SIZE 768 A240 REQUIRES PRIOR UTILITY CONSENT.(Q)WHEN BUILDING PV SYSTEMS WITH POWER LINE COMMUNICATIONS FOR RSD SOLUTIONS, NOTE: (KWAC) MODULE Voc IV) 38.95 FOLLOWING MANUFACTURERS INSTRUCTIONS ON CONDUCTOR AND CONDUIT SPACING IS PARAMOUNT,OR HAZARD MAY RESULT. 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS MODULES 24 JINKO SOLAR (R)NOTIFY ELECTRICAL ENGINEER WHO'S SEAL IS ON THIS DRAWING PRIOR TO ANY AND ALL CHANGES IN DESIGN.(S) PROJECT JKM425N-54HL4-B MODULE Imp(A) 13.13 RELATED SIGNAUCOMMUNICATION CONDUCTORS MAY ONLY BE RUN IN THE SAME CONDUIT WITH POWER CONDUCTORS IF THEIR AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. MICROINVERTER 24 ENPHASE MODULE Vmp(V) 32=37RATING FOR THE OUTER MOST JACKET IS EQUAL TO OR GREATER THAN THE INSULATION REQUIRED FOR THE HIGHEST VOLTAGE 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH IQ8MC-72-M-US MODULE Vmp(V) 32.37 POWER CONDUCTOR CIRCUIT THAT THEY ARE SHARING THE RESPECTIVE CONDUIT WITH. PROPER JUNCTION BOX AT EACH END PER 690.31A NOTE:EGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE WIRE CALCULATION STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE Rev Description Date CURRENT FACTOR FOR ADJUSTED CURRENT CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION 0 INITIAL DESIGN 1129/2024 TAG QTY. SIZE(AWG) DESCRIPTION SIZE&TYPE AMPACITY RATING (°C) APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO A UPDATED DESIGN 12/28/2024 310.15(B)(16) CONDUCTORS 31015(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS e . IN RACEWAY 310.15(B)(3)(a) IN RACEWAY PROJECT# NA 2 12 SKU:Q-12-RAW-300,THHN DATE DRAWN 12/28/2024 A N/A FREE AIR 30 90° 15.96 0.96 1 28.80 19.95 DRAWN BY E.R 1 8 THWN-2 BARE COPPER-(GROUND) SHEET# PV-4.1 3 g THWN-2 COPPER-(L1,L2) TITLE B 3/4" PVC 40 90° 15.96 0.96 1 38.40 19.95 1 10 THWN-2 COPPER-(GROUND) ELECTRICAL SLD EXISTING SERVICE PANEL PHOTOS �EOF"FW L .. r p�87488 �O�SSiOI;P�- ealed 02jan2025 mike@h2dc.com 2DC PLLC NY CoA#:PB-082933 LECTRICAL ONLY RE CONSTRUCTION DRAWING SET THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current _ Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 Emil,Projects@creng.solar Website:viww.creng.ca PHONE: 951-2"_.4 CONTRACTORINFO mum Cc SYSA ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, r NEW YORK 1t952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 S (SUFFOLK HOME IMPROVEMENT) a i MICHAEL KIMMELMAN 1865 HIGHLAND RD, CUTCHOGUE NY11935 AHJ TOWN OF SOUTHOLD UTILITY I LONG ISLAND POWER AUTHORITY (I IPA) PV SUMMARY SYSTEM SIZE(KWDC) STC 425 X 24 =10.200 - PTC 398.1 IX1241=19554 SYSTEM SIZE _ 7.68 @240 (K WAC) MODULES 24 11NKO SOLAR JKM425N-54HL4-B MICROINVERTER 24 ENPHASE IC18MC-72-M-US 2«i r Rev Description Date 0 INITIAL DESIGN 11/29/2024 A UPDATED DESIGN 12/28/2024 B - „� PROJECT# NA DATE DRAWN 12/28/2024 i DRAWN BY E.R SHEET# PV4.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST ELECTRICAL EQUIPMENTS QTY. PART TYPE PART NUMBER DESCRIPTION 24 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B 24 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US 1 COMBINER X-IQ-AM1-240-5/5C Enphase IQ Combiner 5/5C THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current F Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street.Bldg 2 Riverside.CA 92501 Email:Projects@creog.solar Websile v Ycreng.co PHONE.(951)-21&8354 CONTRACTORINFO BREAKER/ FUSES QTY. PART TYPE PART NUMBER DESCRIPTION CZSYS ELEMENT ENERGY LLC. 1 BREAKER 40A 2-POLE BREAKER(S) GENERAL 40A 2-POLE BREAKER(S) 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH'.(631)779 7993 2 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) services@e2sYs com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) MICHAEL KIMMELMAN 1865 HIGHLAND RD, CUTCHOGUE,NY 11935 RACKING AHJ TOWN OF SOUTHOLD QTY. PART TYPE PART NUMBER DESCRIPTION UTILITY ;ONAG ISLAND POWER AUTHORI V 14 RAILS & SPLICES AE-Al-170B AIRE RAIL Al, BLACK, 170" PV SUMMARY SYSTEM SIZE(KWDC) STC 425 X 24 = 0.20D 36 CLAMPS & GROUNDING AE-MID-01-B1 AIRE LOCK MID, BLACK (30MM -40MM) PTC 3981 1X1241=19554 SYSTEM SIZE 7 68 A240 24 CLAMPS & GROUNDING AE-END-01-B1 AIRE LOCK END, BLACK (30MM -40MM) (K WAC) INKO SOLAR MODULES 24 JKM425N-54 1 KM425N-54HL4-B 6 CLAMPS & GROUNDING AE-LUG-01-M1 AIRE LUG MICROINVERTER 24 ENP"ASF IQ8MC-72-M-US 56 ATTACHMENTS AE-DOCK-02-B1 AIRE DOCK, BLACK 56 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK 8 RAILS & SPLICES AE-AlTIE-01-M1 AIRE TIE, Al (BONDED SPLICE) Rev I Description Date 0 INITIAL DESIGN 11/29/2024 A UPDATED DESIGN 12/28/2024 B PROJECT# NA DATE DRAWN 12/28/2024 DRAWN BY ER SHEET# PV-5.0 TITLE BOM CAUTION ��°F"E"' g'�P-„ELM r0 MULTIPLE SOURCE OF POWER 7k� C PHOTOVOLTAIC C p . M In j— 690.12 0 ealed 02jan2025 mike@h2dc.com 2DC PLLC NY CoA#:PB-082933 LECTRICAL ONLY RE CONSTRUCTION DRAWING SET ECT TO TURN RAPID PV SYSTEM ' ' •NNECT THESE PROTECTION BY US LAWBjR PRODUCOTION IN T ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT RATED • ■ - ■ ■ PRIOR WRITTEN APPROVAL FROM CURRENT SHUTDOWN SWITCH TO RENEWABLES ENGINEERING INC. THE "OFF" POSITION TO AC - AC NORMALOPERATING V• 1 VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 ! - Current AND REDUCE SHOCK o • Z J r HAZARD IN THE ARRAY Lu a ID PM DUAL POWERSOURCES 690.56 C = CURRENT RENEWABLES ENGINEERING INC. )�1)�B) • , SOURCE PHOTO— • •IC SYSTEM (, 3600 Lime Street,Bldg 2 Riverside,CA 92501 SECE Websi[e. crenmail g.solar g.co so ■ , AC OUTPUT ■ CURRENT ■ ■ PHONE'.(951)-215-6354 AC NORMALOPERATING V• •GE - 240 VOLTS PV ARRAY CONTRACTOR INFO 690.54 OPTIONAL SOLAR LOAD CENTER imam 0 P� ARRAY EZSYS MAIN SERVICE PANEL ELEMENT ENERGY LLC, 7470 SOUND AVENUE,MATTITUCK, NEW YORK 11952 PH:(631)779 7993 es@e2sys.co R UTILITY METER Licence-ME-52689 J/13 COMBINER MASTER ELECTRICIAN) _ Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) "WARNING" PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL MICHAEL KIMMELMAN INVERTER OUTPUT CONNECTIONPANEL IS AC DISCONNECT PER NYSEC690.17 1865 HIGHLAND RD, D• NOT RELOCATE THIS I CUTCHOGUE,NY 11935 NEC 690.31(G)(3)&(4),CRC R324.7 AHJ TOWN OF SOUTHOLD OVERCURRENT DEVICE "WA - LONG ISLAND POWER AUTHORITY (UNLESS BUSBAR IS FULLY RATED) L _ UTILITY (LIPA) 705.12(D)(2) PHOTOVOLTAIC POWER • - PV SUMMARY SYSTEM SIZE (KWDC) STC 425 X 24 =10.200 EVERY 1U ON CONDUIT AND ENCLOSURES PTC 398.1 IXI241=19554 WARNING SYSTEM SIZE 68 @240 (K WAC) MODULES 24 JKM4JINKO 5KM425N-54-54HL4-B ELECTRIC SHOCK HAZARD ENPHASE MICROINVERTER 24 iQSMC-72-M-US DO NOT TOUCH TERMINALS TERM■IALS ON BOTH LAW i LOAD SIDES NOTE S MAYBE ENEROQ.ED IN OPEN POSITION DO NOT DISCONNECT FUSES UNDER LOAD THE oc CONDUCTORS OF THIS 1. NYSEC ARTICLES 690 AND 705 AND NYSEC SECTION R324 PHOTOVOLTAIC SYSTEM ARE UNGROUI1DEpAND MAYBE ENERGIZED MARKINGS SHOWN HEREON. PHOTOVOLTAIC SYSTEM 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date DC DISCONNECT A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR 0 INITIAL DESIGN 11/29/2024 AUTHORIZED PERSONNEL ONLY MACHINE PRINTED LETTERS OR ELECTRO-PLATING. A UPDATED DESIGN 12)28)2D24 B. RED BACKGROUND COLOR WHITE TEXT AND LINE B WORK. PROJECT# NA Note.WARNING labels muse resemble format C. AERIAL FONT. DATE DRAWN 12/28/2024 1n example above with over-sized WARNING 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY E.R exciamatlon point In triangle.colors.etc THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-6.0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. ENGINEERING DRAWINGS I MECHANICAL CHARACTERISTICS r�one Side Back EAGLENo of Half Cells 10812 x 541 M 0 D U L E S ----- -----? Dimensions 1722 x 1134 x 35mm 167.79.44.65=1.38 inch) i Weight 22.Okg 148.51bsl THEC Front Glass 3.2mm,Anti-Reflection Coating MOST - _ - - ■ High Transmission,Low iron,Tempered Glass EPENDABLE - _ Frame Anodized Aluminum Alloy THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW REPRODUCTION IN 3$$g Junction Box IP68 Rated ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT "' y N_-i7 N Output Cables 12 AWG,1400mm 155 12in1 or Customized WRITTEN APPROVAL FROM CURRENT ed Length RENEWABLES ENGINEERING INC. SOLAR PRODUCT 1 onnectpr Staubli MC< Fire Type Type 1 Pressure Rating 54061oa ISrT,xwl&240OPa 1 Wind) Current { EAGLE 54HM G 6 -- ---------- -_--- --- --- - - - � Engineering TEMPERATURE CHARACTERISTICS CURRENT RENEWABLES ENGINEERING INC. 420-440 WATT N-TYPE TOPCON 3600Lime5tr.Projeg2Rversi.solar 2501 � Leng[h:t 2mm Temperature Coefficients of Pmax -0.29%t°C Email:Projects@crengsolar Positive power tolerance of 0-+3D/D Width::2mm Temperature Coefficients of Vac 0-25%!"C websae www215 co PHONE: 951-2reng- -6354 Height:z 1mm Temperature Coefficients of)sc D-045%/•C Row Pitch:2mm Nominal Operating Ceti Temperature lNOCTI 45i2•C CONTRACTOR INFO • NYSE-listed since 2010.Bloomberg Tier 1 manufacturer • Top performance in the strictest 3"party labs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS Id®m • Automated manufacturing utilizing artificial intelligence Current-Vuttage&Power-voltage Temperature Dependence EZSYS� Operating Temperature I°CI -40°C-.85°C • Vertically integrated,tight controls on quality Curses 144Dwl _ of isc,voc.Pmax Maximum System Voltage 1000VOC ELEMENT ENERGY LLC. • Premium solar factories in USA,Vietnam,and Malaysia i 0 Maximum Series Fuse Rating 25A 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 s >vl PH:(6YO 779 7993 _ e12sys.com Licence-ME-52689 KEY FEATURES - '�- MASTER ELECTRICIAN) r PACKAGING CONFIGURATION LK HOME IMPROVEMENT) (SUFFOLK HOME IMPROVEMENT) Superior Aesthetics " $ I Two pallets=One stack) Black backsheet and black frame create ideal took for - s a --a �• I 31pcsJpatlets,62pcs/stack,806pcs/60 HD Container M I CH AE L K I M M E LMAN residential applications. Voltage(VI �if 1865 HIGHLAND R D, ON-TypeTechnotogy �I CUTCHOGUE NY11935 N-typecettswithJinko"sin-houseTOPCon technology �CeltTemp xiature('CI~ WARRANTY AHJ TOWN OFSOUTHOLD offers better performance and improved reliability. 25-year product and 30-year Linear power warranty O Thick and Tough 1"year degradation not to exceed 1%,each subsequent year no!to UTILITY LONG ISLAND POWER AUTHORITY exceed 0 4%,minimum power at year 30 is 87,4%or eater. (LIPA) �E Fire Type 1 rated module engineered with a thick frame, P y greater 3.2mm front side glass.and thick backsheet for added durability. PV SUMMARY SYSTEM SIZE STC 425 X 24 = 0.200 Shade Tolerant ELECTRICAL CHARACTERISTICS (KwoC) Twin arrayDesign allows continued performance PTC 396.1 X 24= 554 g p Module Type JKM420N-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-8 JKM435N-54HL4-8 JKM440N-54HL4-B SYSTEM SIZE 768 @240 even with shading by trees Or debris. (Kwnc) STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT ANKO SOLAR O - _ Protected Against All Environments Maximum Power IPmaxl 420Wp 316Wp 425Wp 320Wp 430Wp 323Wp 435Wp 327Wp 440Wp 331Wp MODULES 24 JKM425N-54HL4-B ENPHASE yy Cer11lied to withstand humidity,heat,rain,marine environments, Maximum Power Voltage IVmp) 32.16V 29.95V 32.37V 30.19V 32.58V 30.30V 32-78V 30.50V 32.99V 30.73V CROINVERTER 24 IQSMC-72-M-US Wind.had storms,and packed snout Maximum Power Current(Imp) 13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A Warranty Open-circuit Voltage IVocl 38.74V 36.80V 38.95V_ 37.00V 39.16V 37.20V 39.36V 37.39V_ 39.57V 37.59V A 25-year product and 30-year Linear power warranty Short-circuit Current(lscl 13-51A 10.91A 13.58A 10.96A 13.65A 11.02A 13.72A 11.08A 13.80A 11.14A Module Efficiency STC 1%) 21.51% 21.76% 22.02% 22.28% 22.53% Rev Description Date 'STC: w Irradiance 1000W/ml Cell Temperature 25°C (f� AM=1.5 0 INITIAL DESIGN 11/29i2024 • IS09001:2015 Quality Standards ISO45001.2018Occupational U M NOCT:-*-Irradiance 800W/m2 Ambient Temperature 20°C � AM=1.5 �Wind Speed 1m/s • IS0140012015Er,vironmental Standards Health&Safely Standards .� CE � a� us A UPDATED DESIGN 12/28i2024 • IEC61215,IECbl730 certified products UL61730 certified products 'Power measurement tolerance:t3% B -- LISTED ------_-- -- -- PROJECT# NA Solar The company reserves the final right for explanation onanyof the information presented hereby.JKM420-440N-54HL4-8-r7-us !_7 DATE DRAWN 12/2 BUILDING YOUR TRUST IN SOLAR. WWW.JINKOSOLAR.US .lin-K-0 BUILDING YOUR TRUST IN SOLAR.WWW-JINKOSOLAR.US .jnl<O000i WN DRA BY E R�2024 J SHEET# PV-7.0 TITLE MODULE SPEC ENPHASE. ® I08MC Microinverter 00 INPUT DATA DC UNITS IGOMC-72-M US Commonly used media pa n95' w 260-460 To meet compatibility.PV modules must be within tfe folloMYp mas.Input DC vokapx and ma us.module I. wModule compatibility Module compatibility can be checked at W. MPPT voltage range V 25-45 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN Operating range V W58 ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT Min./Max.start voltage V �� PRIOR WRITTEN APPROVAL FROM CURRENT a9 RENEWABLES ENGINEERING INC. Max.input DC voltage V 60 Max.contmuous operating DC current A u Current Max.Input DC short-circuit current A 25 Mmc.module I- A 20 . _ - - 11 0�fl Engineering Overvoltmecd..DC port II DC port'eoldlaadcvntt mA 0 CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street Bldg 2 Riverside,CA 92501 PVarrayeoluNpualfon Ungrounded array:no additional DC side protection required:AC side protection requires max 20 A per branch circuit Email.Projects@creng.solar Websile.www.creng.co PHONE: 951-215E354 Peak output power VA 330 315 CONTRACTOR INFO Max.continuous output power VA 320 310 Nontinal grid voltage(L-U v 240.split-phase(L-U.180' 208.single-phase(L-U.120' Q8M C Microinverter Easy to install Min/Max grid voltage: V 211-264 183-229 Our newest IQ8 Series Microinverters are the indush y's first microgrid-forming'.software- • Lightweight and compact with plug- Max.continuous output current A 1,33 1,49 hase CZ 5Y5 defined microinverters with s Irt- power conversion c and-play connectors p p p capability t0 Convert DC power to Nominal frequency Hz 60 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency Hz 47-68 application-specific integrated circuit(ASIC).which enables the microinverter too rate in between coin equency range ppl� peC g operate components ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, grid-tied or off-grid modes.This chip is built in advanced 55-rim technology with high-speed AC short circuit fault currem over three NEW YORK.11952 digital logic and has su ast response changing g g Faster installation with simple two-wire A-R 2 70 g o9 pt9rf porlse times to cha +n loads and rid events.alleviating cycles PH:(631)779 7993 constraints on battery sizing for home energy systems. cabling sarvioasDe2sys.c0m Max.units per 20 A(L-U brarMdt drealits 12 10 Uponce-ME-52689 (MASTER ELECTRICIAN) High productivity and reliability Total harmonic distortion y 5 Licari -HI-67461 • Produces power even when the grid is (SUFFOLK HOME IMPROVEMENT) down' Overvoltage class AC port 10 - More than one million cumulative hours AC pon backteed current mA 18 M I CH AE L KI M M E L MAN of testing Power factor say rig 1.0 1865 HIGHLAND R D, • Class 11 double-insulated enclosure - ---- ------ -------- ---------- ----------- ---- ----- Part of the En haseEnergy System,S Grrd-tiedpowe-factor(adjlntabie) 0.85 lead ing oaslaggirg CUTCHOGUE NY 11935 p IQ8 Series Microinverters redefine fQ8 Series Microinverters integrate with reliability standards with more than one Optimized for the latest filth-powered the 10 Battery.IQ Gateway.and the million cumulative hours of power-on PV modules Peak efficiency - 97.4 972 AHJ TOWN OF SOUTHOLD Enphase ADD monitoring and analysis testing.enabling an industry-leading CEC weighted efficiency >- 97.0 96.5 software. limited warranty of up to 25 years. LONG ISLAND POWER AUTHORITY Microgrid-forming Nighttime power consumption mw 33 25 UTILITY (LIPA) • Complies with the latest advanced grid MECHANICAL DATA support PV SUMMARY to Ambient temperature range -4t7C to 65°C(-40°F to 149`F) SYSTEM SIZE STC 425 X 24= 0.200 • Remote automatic updates for the (KWDC) a latest grid requirements Relative humidity ran ge 4%to 100%(condensing) PTC 398.1 X 24= .554 • Configurable to support a wide range DCconnector type Staubfi MC4 SYSTEM SIZE(K WAC) 7 68 @240 Of grid profiles Dimensions(H°W,D):Weight 212 mm(8.3')•175 mm(6.9")•30.2 mm(12"):1.1 kg(2.431bs) 11NKO SOLAR Connect PV modules quickly and easily 106 Series Microinverters are UL Listed MODULES 24 )KM425N-54HL4-B to the 108 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-nc,fans ENPHASE integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SE) MICROINVERTER : 24 IOBMC-72-M-US installed according to the manufacturer's Approved for wet locations:Pollution degree yes:PD3 instructions. NOTE: Enclosure Class8double-stsulated,corrosi n resWantpoiymehcenclosure ___— • toe Microinverters canms:be vexed togett>�wins Env"iron.category;W saposure rating NEMA Type 6;outdoor previous gene,at—of Enphase+mcroinvertars (107 Seri-.106 Series,et.J in the same system. •Meet UL D41 only when+iretalied with i0 system Controller 2 and S. IO feGateway is requited to change the detautt grid CA P I(UL T741-SA),UL 62109-1.IEEE 15472018(UL 1741-SB),FCC Part 15 Class B.ICES-0003 Class 8,CAN/CSA-C22.2 NO.107.1-01 proe at the tune of untuanon to meet the Icoal Certifications thlaproduct Is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and Authority Havi g JuPsdoson(ARA requirements. C223-2DIB Rufa64-219 rapid shutdown of PV systems for AC and DC conductors when Installed according to the mmxthebtrar's instructions. Rev Description Date 02023 Enphaae Energy.As right rcenea.Erpruse.the a anal CC logos.to and certain other marks ksted at (1)Noerrtorced DC/ACratfo. 0 INITIAL DESIGN 11/29/2024 / .coin/trademark-usese-wleb—arettadenarksof Erphese Ener ft-tile USandothermmbkn. _._--- ----------- fit 'ramp- gf. (2)Nominel voltage iarpe cac be extended bayed morrNralx raptW bytleuWty Oaraopactmefertga. ----� 10lC�Ce-OSN-00049-3D-ENdii�ZOZYID-! (3)Llmrcs may vary Rare•to local zaquuamennmddar�rr.arbwdnvcrglnwvr.pw brarcfi Yryar are.. 10xMC-MG-DSH-00049-3.o-EN-Us-2023+01e A UPDATED DESIGN 12/28/2024 B PROJECT# NA DATE DRAWN 12/28/2024 DRAWN BY ER SHEET# PV-7.1 TITLE MICROINVERTER SPEC ENPHASE. ® IQ Combiner 5/5C MODEL NUMBER IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV - 10 Combiner 5(X-10-AMt-240-5) production metering(ANSI C1220±0.5%),consumption monitoring(±2.5%),and 10 Battery monitoring(•2.5%).Includes a silver solar shield to deflect heat. ENOWASE fQ Combiner 5C with 10 Gateway printed circuit board for integrated revenue-grade IQ Combiner 5C(X-I0-AM1-240-5C) PV production metering(ANSI C1220±0.5%).consumption monitoring(±2.5%),and IQ Battery monitoring(±2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-MI-06-SP-05)'.Includes a silver Solar shield to deflect heat. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 10 Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive.remote RENEWABLES ENGINEERING INC. maintenance,and management of the Enphase Energy System Busbar 80 A busbar with support for one IQ Gateway breaker and four 20 A breakers for + }- Current installing IQ Series Microinverters and IQ Battery 5P 10 Gateway breaker Circuit breaker,2-poke.10 A/15 A Engineering X-10-AW-240-5 Production CT Pre-wired revenue-grade solid-core CT,accurate up to±0.5% X-I0-AMI-240-5C Consumption CT Two Consumption metering clamp CTs.shipped with the box,accurate up to±2.5% CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 10 Battery CT One battery metering clamp CT,shipped with the box.accurate up to±25% Email websitefewww creng co creng.solair PHONE: 951-2156354 CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Combiner 5/5C 10 Battery 5P CONTRACTORINFO Smart Enphase Mobile Connect(only with IQ Combiner 5C) 4G-based LTE-M1 cellular modem(CELLMODEM-1141-06-SP-05)with a 5-year T-Mobile The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and data Plan streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, includes IQ Gateway for pre-wired solution for residential applications.10 Combiner 5/5C uses wired control communication and control Accessories kit Spare control headers for the COMMS-KIT-2 board communication arid L4 compatible with IQ System Controller 3/3G and 10 Battery 5P. Includes Enphase Mobile Connect o The IQ Combiner 5/5C fQ Series Micrn>in (CELLMODEM-MI-06-SP-05).only verte s.IQ System Controller 3/3G.and with fQ Combiner CELLMODEM-MI-06 SP-OS 4G-based LTE-Mt cellular modem with a 5-year T-Mobile data plan E Z SYS° IQ Battery 5P provide a complete grid-agnostic Enphase Energy System Supports flexible tyetworkag W+-FL CELLMODEM-Mt-06-AT-05 4G-based LTE-M7 cellular modem with a 5-year AT&T data plan ELEMENT ENERGY LLC. EtheaneL Or Cellular 7470 SOUND AVENUE,MATTRUCK, Supports Eaton 8R2XX,Siemens Q2XX,and GE/ABB THOL21YX Series circuit breakers NEW PORK,11952 PH:(631)779 7993 Provides production metering Circuit breakers(off-the-shelf) (XX represents 10.15,20.30.404 50.or 60).Also supports Eaton BR2208.BR23013.and service.the2sys,com (revenue grade)and consumption BR240B Circuit breakers compatible with the(told-down kit. U-n_-ME-52689 (MASTER ELECTRICIAN) monitoring Licence-HI-67461 Circuit breakers(provided by Enphase) BRK-IOA-2-24M BRK-15A-2-24OV.BRK-20A-2P-24OV,BRK-15A-2P-24OV-B,and (SUFFOLK HOME IMPROVEMENT) BRK-2OA-2P-240V-B(more details in the'Accessories"section) It 6 Easy to install )(A-SOLARSHIELD-ES Replacement solar shield for iQ Combiner 5/5C M I CH AE L K I M M E LMAN IQ Series Microinverters IQ System Controller 3/3G Mounts to one stud with centered The high-powered smart grid-ready IQ Series Provides mscrognd interconnection device brackets XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board(PCB)for IQ Combiner 5/5C 1865 HIGHLAND R D, Microinverters(IQ6.IQ7.and 108 Series) (MID)functionality by automatically detecting Supports bottom.back.and side X-I0-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws) CUTCH OG U E NY 11935 simplify the installation process. grid failures and seamlessly transitioning conduit entries the home energy system from grid power to XA-COMM52-PCBA-5 Replacement COMMS-KIT-2 printed circuit board(PCB)for IQ Combiner 5/5C AHJ TOWN OF SOUTHOLD backup p—. Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers --- (rot included) UTILITY LONG ISLAND POWER AUTHORITY Rating 80 A (LIRA) e.....x 80 A total PV branch circuits - System voltage and frequency 120/240 VAC or 120/206 VAC.60 Hz PV SUMMARY Bluetooth-based Wi-Fi provisioning SYSTEM SIZE STC 425 X 24 = 0.200 for easy Wi-Fi setup Busbar rating 125 A Kwoc) PTC 396.1 X 24 = .554 Fault current rating 10 I AIC SYSTEM SIZE 7 66 @240 Reliable (K WAC) Maximum continuous Current rating64 11NK0 SOLAR 10 Battery 5P 10 Load Controller Durable NRTL-certified NEMA (input from PV/storage) A MODULES za type 3R J1 NKO SOLAR Fully integrated AC battery system.Includes Helps prioritize essential appliances during a enclosure MICROINVERTER 24 ENPHASE six field-replaceable IQ8D-BAT Microinverters. rid outage to optimize energy consumption 5- y storage) Up to four erpole Eaton BR.Siemens Q or GE/ABB THQL Series distributed generation D8MC-72-M-US g 9e gy pt year limited warrant Branch circuits(solar and/or store ) (DG)breakers only(not included) and prolong battery life. 2-year labor reimbursement program Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IQ Gateway breaker included coverage included for both the IQ Combiner SKUs' 10 Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included NOM z UL1741 Listed Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Ly�� Consumption monitoring CT(CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box Rev Description Date Q IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering,included with the boot 0 INITIAL DESIGN 11/29/2024 5-year limited warranty ----------—-------- -------------- A UPDATED DESIGN 12/28/2024 B 'For country-specific warranty information.see the PiT:i)s:/,,enDhase.com/instaliersiresources/warranv page. PROJECT# NA A plug-and-play indUStr12l-grade cell modem for systems of up to 60 microinverters.Avallable In the United States.Canada Mexico,Puerto Woo.and the US Virgin Islands,where there Is adequate 62024 Eriphass Energy.NI rights raa ac-Enphasa the a and CC logos.la and certain other marks listed at cellular service in the Installation area. DATE DRAWN 12/2W2024 https//enphase.com/trademark-usape-ouwmes are trademarks of Enpnase Energy.Inc.in the U.S.and other counmtc. DRAWN BY ER Data subject to charge. IOC-5-5C-DSH-00007-5.0-EN-US-2024-08-16 IOC-5-5C-DSH-00007-5.0-EN-US-2024-08-16 SHEET# PV-7.2 TITLE COMBINER SPEC • •• • Components Aft IRONRIDGE Aire Flush Mount System Aire`Al Raii Aire"A2 Rail A W Roll Tiss Aires Dock THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT • • •.• -z ------ PRIOR WRITTEN APPROVAL FROM CURRENT • • RENEWABLES ENGINEERING INC. The lighter,open Aire' The tougher,open Aire' rail Structurally connect and Connects Aire' Rails to rail for standard conditions. for higher load capacity. bond Aire'" Rails together attachments with ease. 6 spanning capability 8'spanning capability Reinstallable, up to 5x Clicks on,slides easily r C.If rer Wire management tray Wire management tray Internal splice design Drops into open slots Mill or anodized black Mill or anodized black No more splice rules Anodized assembly Engineering /r CURRENT RENEWABLES ENGINEERING INC. Clamps&Grounding 3600 Lime StreoLBldg 2 Riverside CA 92501 Email Projects@creng.solar Web"':_ renco g. Airs*Lock Milds Aire" Lock Ends Aire! Lock Stealtht Aires Lug PHONE 951-2,5635a CONTRACTORINFO Alum EcSYS* Securely bend between Securely bond modules to Securely bonds modules to Bonds Aire Rails to modules to Aire`" Rails. Aire' Rails alongends. rail ends.entire) hidden. grounding conductors. ELEMENT E UE. LLC Y 9 9 7A70 SOUND AVENUE.MATfITUCK, 4y NEW YORK,11952 \,F • Fits 30-40mm modules Fits 30-40mm modules Angled for easy install • Simplified with single bolt PH.(63,)7797993 ser ces@e2sys.00m Utilizes UFO°design Easy rail engagement Robust tether leash Low-profile form factor Lucer ME 52699 Minimal 1/2"gap Clean aesthetics Fits most modules Works with 10-6 AWG MLce Re_HI-6 461 Breathe easy With accelerated installat'lon (SUFFOLK HOME IMPROVEMENT) 41i�'C.rf�arleS _. The Aire` racking system has been carefully engineered to streamline every part of the installation process. MICHAEL KIMMELMAN We've eliminated tiresome hassles,so that you get off the roof and on to your next project faster than ever. Aird Caps Aire="Clip Aire' MLPE Mount Aire'All Tile Hook 1865 HIGHLAND RD, Aire retains the strength and reliability that IronRidge installers depend on. It also takes wire management to CUTCHOGUE,NY 11935 the next level with the first(and only) NEC-compliant rail, formally approved and listed as a cable tray. Q AHJ TOWN or SOUTHOLD ® LONG ISLAND POWER AUTHORITY UTILITY (LIPA) Strength Tested PE Certified PV SUMMARY • SYSTEM SIZE STC 425 X 24 = 0200 All components have been evaluated Pre-stamped engineering letters are Block entry and provide a Keeps wiring contained in Securely bonds MLPE and Attaches rails to tile roofs, Kvwc) PTC 396.1 X 24 = 554 for superior structural performance. available online for most states. finished look to Aire` Rails. open Aire" Rail channels accessories to Aire' Rails. with Aire' Dock included SYSTEM SIZE(K WAC) 768 @240 Stay secure on rail ends No module interference Glove-friendly installation Works on flat.S.&W tiles MODULES 24 nNKo SOLAR Symmetrical.with drain Simple press-in design Lays flush in rail channel Single-socket installation KM425N-54HL4-B Class A Fire Rating Approved Cable Tray MICROINVERTER P4 EN PHASE Cover rough-cut ends Slot for easy removal Low profile form factor Optional deck flashing =C7z-M-us Certified to maintain the fire resistance Open channel listed to NEMA VE 1, rating of the existing roof structure. certified to hold PV and DG cables. Resources - - - = Design Assistant Y8o1*, Approved for FL Hurricane Zones LIL 2703 Listed System 25-Year Warranty Quickly go from rough layout '•, ° +' Aire` has Florida Product Approval �• IF. F: Rev Description Date to fully engineered system pi , = Additional details can be found on the o INITIAL DESIGN „/zs/zo2a ® Entire system and components meet Products are guaranteed to arrive _ _ Florida Buildin Code website. Go to IronRidge.com/design % 'TPFOf g t '2°ppK .@\�� A UPDATED DESIGN 12/28/2024 the latest effective UL 2703 standards. without any impairing defects. -�� PROJECT# NA DATE DRAWN 12/28/2024 tO r reseivied.U.S.Patients Pending.Versi� r DRAWN BY ER SHEET# PV-7.3 TITLE RAIL SPEC /g" IRONRIDGE QuickMount' Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home, solar attachments • • THESE DRAWINGS ARE SUBJECT TO COPYRIGHT must be dependable for the lifetime of the rooftop. PROTECTION BY US LAW. REPRODUCTION IN Due to recent innovations. man asphalt shingles ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT Y P 9 — t PRIOR WRITTEN APPROVAL FROM CURRENT have bonded courses-A mount that protects without _.... RENEWABLES ENGINEERING INC. the need to pry shingles can really speed things up. - _____ • • - �- • • • - Current Halo UltraGrip"(HUG`) is here to respect the roof. Its Halo is a cast-aluminum barrier that encases the ,. UltraGrip,our industrial-grade.foam-and-masticIry Seal.This allows HUG to accelerate the Installation CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street Bldg 2 Riverside.CA 92501 process and provide the utmost in waterproofing r E Miss the mail Projects@creng solar Hit the rafterli Good to go! protection. Give your roof a HUG. Try it Sill no luck?Install the weesaecren9co When you • • -on. .,•another screw to the leftor PHONE.(951)-215 6354 Only 2 RD Structural Screws are needed. rafter is found.install 3rd and final screw secure six screws to deck mount it CONTRACTORINFO rs Mufti-Tiered Waterproofing HUG'utilizes a mufti-t,ered static of components to provide revolutionary Trusted Strength & Less Hassle •alierproohng protection The Halo cast- akiminum,raised-perimeter foundation Cc SYS the UltraGnpbase—a foam- Structural capacities of HUG' were reviewed in r, mam seal corronabOn that many load directions,with racking rail running ELEMENT ENERGY LLC. --.-��� by 7470 SOUND AVENUE,MATTITUCK, 1�1 the Shingle Surface cross-slope or up-slope in relation to roof pitch. NEW VORK,11952 PH.(631)779 7993 service ye2sys.com UltraGrip~is part For further details. see the HUG certification Licelnce-ME-52689 QUICkMOunt` (MASTER ELECTRICIAN) line. letters for attaching to rafters and decking. Dcence-HI-67461 }- (SUFFOLK HOME IMPROVEMENT) __ -- - IronRidge designed the HUG. in combination UkraaGrip°Seal Technology with the RD Structural Screw to streamline MICHAEL KIMMELMAN HUG UftraGrp utilizes astalI f installs. which means the following: 1865 HIGHLAND RD, art seal design that uses a unique, - CUTCHOGUE,NY 11935 foam-and-mastic comtimation.The foam-backed adhesive provides an les AHJ TOWN OF SOUTHOLD enntiretynew flashing system that No prying shingrfe conforms and adheres to 2-Y�Warr No roof nail interference every tinny • No plot holes necessary UTILITY LONG ISLAND POWER AUTHORITY and cranny of composition Stkrtgles,. _ .. � F•todtct guarartl••d free (uPA) filling gaps and shingle step-downs; - - • o sealant(In most cases) 1. (up to 118-in height) z • No butyl shims needed PV SUMMARY [(KWDC) STEM SIZE STC 425 X 24 = 0200 PTC39814 ' STEM SIZE 7 68 �240AC)• . • • • • DULES 24 11NK0 SOLAR 1KM425N-54HL4-B ICROINVERTER 24 TEQNS.1 C572-M-1S Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUGS"to the roof rafters.the roof i •� deck.or both with our custom-engineered HUG has been and certified for the UL 441 Section UL 2703 mechanical - RD(rafter-0I-deck)structural screw.The RD tested and rated to i compliance with 27"Rain Test"and and bonding OTriple Rated&Certified Structural Screw anchors HUG to the roof to Respect the Roof • . support 1004(Ibs)of the International TAS 100(A)-95 requirements. See Rev Description Date � with an k of w seating washer.completing uplift and 368 Ibs BuildingCode& ', "Wind Driven Rain Flush Mount Manual 0 INITIAL DESIGN 11/29/2o-4 UL 2703,441(27) the stack of waterproofing bamers.See p ( ) Intertek TAS 100(A)-95 backside for more Installation information of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. A UPDATED DESIGN 1228120 4 B - PROJECT# NA !_ DATE DRAWN 1 212 8/2 0 24 0 2023 IronRidge,Inc.All rights reseirwed.Visit www.ir-patents.com for patent inomiation.Version 1.03 DRAWN BY E.R SHEET# PV-7 4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd 28357 Industrial Blvd Hayward.CA 94545 Hayward.CA 94545 RON RI DGE 1-800-227-9523 I RON RI DGE 1-800-227-9523 IronRidge.com IronRidge.com Attn:Corey Geiger, COO, IronRidge Inc. Date:July 15tr'.2022 The parameters and adjustments allowed in the span tables are defined as the following THESE DRAWINGS ARE SUBJECT TO COPYRIGHT 1. The Aire Rail System is designed as a Risk Category II structure as defined b ASCE 7-10 Chart 1 5-1 PROTECTION BY US LAW REPRODUCTION IN Re: Structural Certification and Span Tables for IronRidge Aire Rail System y g g ry y ANY FORM I TEN APPROVAL FORBIDDEN CURRENT WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 2 The wind speed selection shall conform to ASCE 7-10 Fig 26 5-1A(Risk Category II wind)and any state&local This letter addresses the structural performance and code compliance of IronRidge s Aire Rail System.The contents of county/city amendments to the IBC No special wind topographic features are included in the span tables and the the letter shall be read in its entirety before applying to any project design.The Aire Rail System is a proprietary rooftop topographic coefficient(Kzt)is taken as t0. Current mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum Aire Rails and are secured to the rails 3. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig 7-1 and �n with IronRidge mounting clamps.The Aire Rails are mounted to a roof attachment using the Aire Dock and 3/8"hardware applicable state&local county/city amendments to the IBC If the local jurisdiction specified snow load is in the Engineering and the attachment is secured directly to the underlying roof structure.Assembly details of a typical Aire Rail System format of a flat roof snow load it shall first be converted to a ground snow following the local building CURRENT RENEWABLES ENGINEERING INC. Installation and its core components are shown in Exhibit EX-0021 code/amendment before the application of the attached span tables. No special snow conditions are considered 3600 Lime StreetrBle �cireng sofa A 92501 Em it including unbalanced,drifting sliding, retention.or ponding snow The span tables do not include buildings which websae a crengco PHONE'.(951-215b354 The IronRidge Aire Rail System is designed and certified to the structural requirements of the reference standards listed are intentionally kept below freezing, kept just above freezing,or unheated CONTRACTORINFO below.for the load conditions and configurations tabulated in the attached span tables. 4. The span tables reflect the ASCE 7 prescribed earthquake Toads with the maximum magnitudes being: ASCE/SET 7-10 Minimum Design Loads for Buildings and Other Structures(ASCE 7-10) • 2015 International Building Code(IBC-2015) a) For ground snow no greater than 42psf:Ss<_2.Og for Site Class A, B,C,or D. b) For ground snow greater than 65psf:S<<_ 1.0g for Site Class A, B,C.or D. . 2017 NYS Uniform Code Supplement �/ • 2015 Aluminum Design Manual(ADM-2015) c) For ground snow between 42 and 65psf:SS s 1.5g for Site Class A. B,C,or D. EZ S T SL 5. Roof zone size and definition conforms to ASCE 7-10 Figures 30.4-213 and 30.4-2C. 7470 ELEMENT OUND AVENUE MATTiTUCK. The tables included in this letter provide the maximum allowable spans of the Aire Rail System for the respective loads NEW YORK,11952 PH'.(63I)779 7993 and configurations listed.covering wind exposure categories B. C &D roof zones 1.2,&3,and roof slopes of 8�to 45` 5e.i @ 2sys com 6. The maximum rail cantilever length, measured from the rail end to the nearest attachment point,shall be the Licence-ME-52689 The tabulated spans are applicable when the following conditions are met' lesser of the following two conditions. 1/3 of the allowable span provided for the respective load&configuration MASTE ene LH`T67i461 condition from the span tables.or 36 (SUFFOLK HOME IMPROVEMENT) 1 Span is the distance between two adjacent roof attachment points(measured at the center of the attachment 7. An array to roof clearance of 2' minimum must be provided. MICHAEL KI MMELMAN fastener) 1865 HIGHLAND RD, 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system). Spans are calculated based on & Aire Tie rail splice can be installed at any location within a span. No splices are allowed in the rail cantilever. CUTCHOGUE,NY 11935 2 rails stems and are conservative) deemed acceptable for 3 rails stems AHJ TOWN or SOUTHOLD Y Y P Y 9 Shaded cells of the span tables indicate conditions in which Aire Lock Mid Clamp connection capacity is exceeded. It such conditions are encountered contact techsupport(Q7ironndge.com. UTILITY LONG ISLAND POWER AUTHORITY 3. The underlying roof slope. measured between roof surface and horizontal plane is 8°to 45' (UPA) PV SUMMARY SYSTEM SIZE 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from (KWDC) STC 425 x 2,l = 0200 grade.does not exceed 30 feet. PTC 396.1 X 24 = 554 SYSTEM SIZE 7 68 �240 (K WAC) 5 Module length and area shall not exceed the maximum values listed on the respective span tables. MODULES 24 1INKO SOLAR 1KM425N-54HL4-B MICROINVERTER 24 ENPHASE 6, All Aire Rail components shall be installed in a professional workmanlike manner per IronRidge s Aire Rail IQ8MC-72-M-US Installation Manual and other applicable standards for general roof construction Rev Description Date 0 INITIAL DESIGN 11/29/2024 A UPDATED DESIGN 12/28/2024 B 2022 IronRidge Inc NY Aire Rail System Certification Letter-1 t 2022 IronRidge.Inc NY Aire Rail System Certification Letter-2 PROJECT# NA DATE DRAWN 12/2a/2024 DRAWN BY ER SHEET# PV-7.5 TITLE CERTIFICATION 28357 Industrial Blvd Hayward, CA 94545 23RONRIDGE IronRidge com 10. Systems using Aire Lock Stealth module clamps shall be installed with the following guidance: a) Aire Lock Stealth will function within a module's design load ratings. Be sure the specific module being used with Aire Lock Stealth meets the dimensional requirements shown in the figure below and that the module selected is suitable for the environmental conditions of a particular project. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Module Gloss/Cells C jrrert -0 Erglneel-irg CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 Email P,q-tsLdcreng—lar Wel"e www.creng.co PHONE. 951-215E354 Frame Compatibility: X = 1-5mm CONTRACTOR INFO Y= 8-35mm Ia®n EZSYS? ELEMENT ENERGY LLL. 7470 SOUND AVENUE,MAITITULK, Figure 1.Aire Lock Stealth Module Frame Dimensional Requirements NEW YORK,11952 PH:(631)779 7993 es@e2sysc Licence-ME-52639 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) The span tables provided in this letter are certified based on the structural performance of IronRidge Aire Rails only with MICHAEL KIMMELMAN no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and 1865 HIGHLAND RD, adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array CUTCHOGUE,NY 11935 configuration. This letter certifies the IronRidge products referenced within this document and provides no determination AHJ TOWN OF SOUTHOLD of the project specific conditions including site loads. building profile. & roof zones, which remain the responsibility of the UTILITY LONG ISLAND POWER AUTHORITY (LIPA) installer or system designer. PV SUMMARY SYSTEM SIZE(KWDC) STC 425 X 24 = 0.200 PTC 396.1 X 24 = 554 OF NEW SYSTEM SIZE 7 68 _240 NG XU yO _ Digitally signed )INKOSOLAR CID Sincerely, GP QA- 9� MODULES 24 )KM425N-54HL4-B by Gang Xuan MICROINVERTER 24 ENPHASE t— IQBMC-72-M-US LU _ —__ z Date: 2022.07.19 410 096579 08:45:30 -07'00' RGFESS04 Rev Description Date 0 INITIAL DESIGN 11/29/2024 Gang Xuan, PE A UPDATED DESIGN 12/28/2024 B Senior Structural Engineer PROJECT# NA DATE DRAWN 12128/2024 DRAWN BY ER SHEET# PV-7.6 ©2022 IronRidge.Inc NY Aire Rail System Certification Letter-3 TITLE CERTIFICATION