Loading...
HomeMy WebLinkAbout51498-Z of Soulyo`o Town of Southold * * P.O. Box 1179 53095 Main Rd Ufa% ' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 46014 Date: 03/05/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 310 Duck Pond Rd Cutchogue, NY 11935 Sec/Block/Lot: 83.-2-19.11 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 10/29/2024 Pursuant to which Building Permit No. 51498 and dated: 12/19/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to: Bozena Skuriat-Krolik,Kajetan Krolik Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51498 02/26/2025 PLUMBERS CERTIFICATION: Author zed Signature Of SOpryO�C TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51498 Date: 12/19/2024 Permission is hereby granted to: Bozena Skuriat-Krolik PO BOX 455 Cutchogue, NY 11935 To: install roof-mounted solar panels on existing single-family dwelling as applied for. Premises Located at: 310 Duck Pond Rd, Cutchogue, NY 11935 SCTM#83.-2-19.11 Pursuant to application dated 10/29/2024 and approved by the Building Inspector. To expire on 12/19/2026. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total S325.00 Building Inspector OF SOUr�,�l h O Town Hall Annex Telephone(631)765-1802 54375 Main Road Abc P.O.Box 1179 G OQ Southold,NY 11971-0959 MUNTN,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Bozena Skuriat- Krolik Address: 310 Duck Pond City: Cutchogue St: NY Zip: 11935 Building Permit#: 51498 Section: 83 Block: 2 Lot: 19.11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: NYS Essential Power Inc License No: 64897ME SITE DETAILS Office Use Only Indoor P-7 Basement FYI Service F Solar 1✓ Outdoor 1✓ 1st Floor [✓ Pool r Spa r Renovation F 2nd Floor Hot Tub r Generator Survey Attic 1— Garage Battery Storage (— INVENTORY Service 1 ph r Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph (� Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 4.14kW Roof Mounted PV Solar System w/ (9)REC460AAPure-RXModules, 20A AC Disconnect, Combiner Panel w/20A Breaker, On 20A Backfed Breaker in Main Panel Notes: Solar Inspector Signature: X Date: February 26, 2025 Sean Devlin Electrical Inspector sean.deviina-town.southold.ny.us 310DuckPondSolar SOGTyO� # TOWN .OF SOUTHOLD BUILDING DEPT. cao 631-765-1802 INSPECTION [. ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. ] FOUNDATION 2ND - [ ] I SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL ,So1a4e_ [ ] FIREPLACE Z CHIMNEY [- ] FIRE:SAFETY INSPECTION ] FIRE RESISTANT-CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ - ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: c.o. DATE INSPECTOR ho�aOF SOUIyo� -- * * T N OF SO.UTHOLD BUILDING DEPT. coum,��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ _ ] ROUGH PLBG. [ ]: FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/.STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]" FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION. [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]. PRE C/O [ ] RENTAL REMARKS: l\4issi,, 4, c /Kr/f o e2ar46�4e4 11QU4 9/ S`Nleyrlo an DATE 0. � INSPECTOR / ho��OFSOUlyo6 1-4 q 8 U�_kParvi, # ` .TOWN OF SOUTHOLD BUlLDtNG DE PT. 631-765-1802 INSPECTION [ ] FOUNDATION-1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND­ INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION- . [ .] FIRE RESISTANT CONSTRUCTION- f ]. FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: e 0� DATE !L INSPECTOR Chun Feng, RA 409 Jackson Ave Twp of Washington, NJ 07676 Phone: (201) 638 58511 Fax: (201) 934 8260 Date: February 3, 2025 Building Official Building Department Town of Southold Re: Solar panel installation at 310 Duck Pond Road, Cutchogue NY 11935 ATTN: Building Official Permit Date of Issuance and Number: 10/29/2024, 51498; 83-2-19.11 Town of Southold, I, Chun Feng, certifies the installation meets the town of Southold's approved plans and all manufacturer specifications. The installation, as performed, meets the requirement of the 2020 Residential Code of New York and the provision of ASCE 7-16. If you have any questions, please do not hesitate to contact me at (201) 638-5851. Thank you Truly yours, RERAN C�eng, 11 FEB - 6 2025 Building Department Town of Southold i FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION (1ST) _ -- -- ------------------------------------ -- � C r � FOUNDATION (2ND) O C\o y vim' ROUGH FRAMING& j a PLUMBING - - r r� INSULATION PER N.Y. y STATE ENERGY CODE - `,- FINAL ADDITIONAL COMMENTS - C 4. M N b x - v -o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold;NY 11971-0959 Telephone(631)765-1802 Fax'(631)765-9502 hops://www.southoldtomM- .gov Date Received APPLICATION FOR BUILDING PERMIT s-� E C Ell WE For Office Use Only C % OCT 2 9 2024 PERMIT NO. �J Building Inspector: Applications and forms must be#illed out-in their entirety. Incomplete Building Department applications ''not be accepted, Where the Applicant is not the owner,an Town Gf Z`Outiiold Owner's`Authorization form(Page 2)shall be completed. Date:10/23/2024 OWNER(S),OF'PROPERTY: Name:Bozena Skuriat-Krolik SCTM#1000-083.00-0200-019.110'. Project Address:310 Duck Pond Road, Cutchogue NY 11935 Phone#:646-752-9455 Email:bosku@aol.com - Mailing Address:310 Duck Pond Road,Cutchogue NY 11935 CONTACT;PERSON:' Name:Krzysztof Kaminski/.Amanda Pabon Mailing Address:117 Bay 8th Street, Brooklyn NY 11228 Phone#:(718)490-0208 Email:apabon@kamtechsolar.com DESIGN PROFESSIONAL.INFORMATION: ;. Name:Chun Feng, RA Mailing Address:409.Jackson'Avenue, Township of Washington NJ 07676 Phone#:(201)63&5851 Email:cfeng3000@gmail.com CONTRACTOR INFORMATION: Name:Krzysztof Kaminski (Kamtech Restoration Corp.) Mailing Address:117 Bay 8th Street, Brooklyn NY 11228 Phone#:(718)49070208 Email:apabon@kamtechsolar,com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost'of Project: 2Other Installation of solar PV panels flush mount to roof- $8,300 Will the lot be re-graded? ❑Yes ONo Will excess fill be removed from premises? ❑Yes RNo 1 e V PROPERTY INFORMATION�-" r Existing use of property:Residential (1 Family) Intended use of property:Residential.(.1 Family)-,No cha Zone or use district in.which.premises is situatedc Are there any covenants and restrictions with respect to AC this property? ❑Yes [i]No IF YES, PROVIDE A COPY. �.Check fBox After Reading: The owner/contractor/design professional Is responsible for ali drainage and€storm water issues as provided by Chaptet,136'of the Town Code.APPLICATION IS HEREWMADE to the Building Department for the issuance of a Building Permit pursuant to thwpuiliiing zone', Ordinanceof the Town of Southold,Suffolk;County,New York and other applicable Laws,Ordinances orAdgulatioM,for the construction of buildings; addit!ons,:alteiations,or for remove or denolition as herein described.The applicant agrees to comply with ali applicable Iaws,Eordinance's,building code,, ;housing code and regulations and to:admit•adthorized inspector's on premise-s and in building(s)for necessary'inspections.False statements made herein are punfshable'asa Class A misdem eanor pursuant to Section,210.45 of the New York State.Penal JLaw: K sztof•Kami i Application Submitted By(prin ame): MAuthorized(Agent . ❑Owner. Signature of Applicant: Date: 10/23/2024 STATE OF NEW YOR SS: COUNTY OF Kings ) Krzysztof Kaminski being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, Contractor (S)he is the . (Contractor,Agent,Corporate'Officer,etc:) of said owner or owners, and is duly authorized to perform or have performed the said work and.to make.and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and ; that the work will be performed in the manner set forth in the application file therewith. _ Sworn before me this 23 day of October 20 24 N Y _ I NA COLON PGQIU86763 UAL 'IN.KINGS-COUNTY M ISSION EXPIRES 01`28-2027 PROPERTY OWNER,AUTHORIZATION (Where the applicant is not-the owner) l3ozena Skuriat-Krolik 310 Duck,Pond-Road, Cutchogue NY 11935- I, residing.at Krzysztof Kaminski/Kamtech Restoration Cori do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval,�as described.herein. _ 10/23/2024 Owner's Signature Date Bozena Skuriat-Krolik Print Owner's Name 2 D ECED V E SutF��K BUILDING DEPARTMENT- Electric I sp Doti° coG�� e TOWN OF SOUTHOLD 7 2025 =� Town Hall Annex- 54375 Main Road - PQQ��B 1199 co '? Southold, New York 11971-095Jui[ging epartment Town of Southold Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh _southoldtownny.gov— seand(@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/7/2025 Company Name: NYS Essential Power Inc. Electrician's Name: Sean Deptula License No.: ME-64897 Elec. email: operations@essentialpower.net Elec. Phone No: (631)400-2680 01 request an email copy of Certificate of Compliance Elec. Address.: 333 Smith Road, Shirley NY 11967 JOB SITE INFORMATION (All Information Required) Name: Bozena Skuriat-Krolik Address: 310 Duck Pond Road, Cutchogue NY 11935 Cross Street: Oregon Street and Ihar Lane Phone No.: 646-752-9455 Bldg.Permit#: 51498 email: bosku@aol.com Tax Map District: 1000 Section:83 Block: 2 Lot: 19.11 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of solar panels flush mount to roof. Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In �;Final Do you need a Temp Certificate?: ❑ YES FV] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y LJN Additional Information: PAYMENT DUE WITH APPLICATION D E C E WE BUILDING DEPARTMENT- Electric I spe ` - 7 2025 TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PQ�B 1199 o � �1 Southold, New York 11971-095 °�1? Ing f5epartment Town of Southold Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh(aD-southoldtownny.gov — seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (AII Information Required) Date: 2/7/2025 Company Name'-,-NYS Essential Power Ic'n . Electrician's Name: Sean D,eptula License No.: ME-64897 Elec. email: operations@essentialpower.net Elec. Phone'No: (631)400=26.80--='--_ 01 request an email copy of Certificate of Compliance Elec. Address.: 333 Smith Road, Shirley NY 11967 JOB SITE INFORMATION (All Information Required) Name: Bozena Skuriat-Krolik Address: 310 Duck Pond Road, Cutchogue NY 11935 Cross Street: Oregon Street and Ihar Lane Phone No.: 646-752-9455 Bldg.Permit#: 51498 email: bosku@aol.com Tax Map District: 1000 Section:83 Block: 2 Lot: 19.11 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of solar panels flush mount to roof. Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES ❑ NO ❑Rough In ❑� Final Do you need a Temp Certificate?: ❑ YES ❑� NO Issued On Temp Information: (All information required) t Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 R2 7 H Frame 0 Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION AUG 18 198A Y s.0 W.OF �w HULTH S"IES. d d 05 P / �• ; ci 20 �. A� • � ao• I P�s , q j y�g D`to,11 �1 1 �. � fi `. jb G cb ,. c� (Lot l T 20 y. of SUFFOLK COUNTY ALT&PEPA MENT SINGLE FAMILY D LLIia ON 1kO� H.D.REF.NO. DATE THE SEWAGE DISPMAL AND WATER SUPPLY FACILITIES FO 8 OCATION HAVE BEEN INSPECTED BY THIS DEPARTMENT A D� OUND TO BE SATI ORYQ— PE - — Chief of W t9INMOr Management Section SURVEY FOR PHILL/PE MAVW EL JaE.Y 2v,Ow FEB. 27,/9B6 AT CUTCN06ME DATE, JULY/O,/995 TOWN OF-'Vj7 117LD SCALE, / " C 50 SUFFOLK COUNTY,NEW YORK NO. 85-6/9 odaulNoAi{{o ALTWTION Or ACOITNwI To IwIs �as {VAV[r 8ar10.a110M W1 [{eTlmN no*pr Tw{ wTIWLC uvw1.8 rYl[ ' MEr rOr[[TAT[{OAV91 N Lat +: M 91 O THIa tIMV[r NOT a[AA o rwt Uwa AVAV[rar'[WIILD�t{AL ON[IBt00[[D arAL"ALL 'fit pF N{'»,` IIOT[t CW 1S!'"I L0 TO{[A WLIO TAOt L I p raYAAANTtp w101TATto N[KOw OHLL NIRI OMIr to HEALTH DEPARTMENT-DATA FOR'APPROMIL To CONSTRUCT T"t�1 �oA cram.TNc TITLE a Plr sav + ANO a Nit�KIMAf ro tD LENDING Oil ITUTION LISTED M[{/P OQt ai li r�r�iln utT1011Ji LOT�O rMt row. r Tw{ ta IISPS Of T[LL[YgM o rTH[A['AM MO aTItLLfalY VITIN 100 K[f W TNa MO►drr w1[TIrVTIOw WAPAHTtt[Art HOT 111YA[R11h[ OTNto MAY Twu Loom Ntll{Or. 10 AOOITIOw�L MI{1NYTwMt Or tY[f[ w r TWCWA"a 90ftV AO a tOM O[N&/T[TIX FOA TNI{xaloa= OWNERS IPNLmrr,- To THE/TANaWs OF TNt'tVF►QL[[OMIT OVA[TIrINT ■oRAISING TN"IC NES A ran A SFECI I uwu TO[[I[Tr1A tTR S POT T AN[►oa a{ISTAS OF N[LLTN faWlCtt. PONFCft 101 AN[Nor rT K Nam om or Fi e • urLl[Arr. .. PNortrrr uwto a wp rws ua¢rlow eF rerea - uaa ADDRESS +0005MANDER AVENUE' YOUNG a YOUNG RIVERNEAD,NEW YORK AM, •+ AgNL4W*7 p+S7AAT ALDEN W.VOUNO,PROFESSIONAL ENGINEER AND LAND SURVEYOR N.V.<UCENSE II0.12043 HOWARD W.YOUNU, LAND SURVEYOR IS TN[LOCAIYI or raLlrl,wlree wwNtrla Cf{{IOOLf10►?wo,Fw wM[Ow N.Y S.LICENSE 140.I5493 Alit IrOY niLD oa{tNl.iwrr AwooAMTA arA/lta PTiWI orwa[ T 9owd w>N /IOIM - - ,rti\\t'•�` t °t°"yya,°',°`.` �4:ti-:"`.1'ri F+�.'•r.Js�'. -'t�.il•J`i•�:r1 JeT. r�. ♦r7rw rr" •r•♦ - ,•y � Sett 'ry;r�.y tI'��a r�.�''/{�}�i���td,�"y'�a,�� ��[?'. ° 1,:• .sa ,°i..c\• � .�.•.`��;µ1t.^•,a'St �:-r. '!� ;%�'`. ._�. I /. .•% i I'� .6! �� iJt`h •�iS,\�!'�+5w ii S-�7f 9aj1�r C�4;ara��;y��s'�iq \ - . { ` ,°`.\�., ,gi s..q 1�4��v..Yt+`.: .:"",`" '•�'__ rfd Lr', s r'_-j". r.� i'_•r.. _`. \ ,\q••'ttt`15:�''I�:���'�`+:; 4'`,�°'rti 1�.'f!^�,a"Y+�T °"'1 4 _ \.� •+ °ice'. ~ °i�t.t \ 4',••�s 'i -,r :✓:.�j i'''. ,a• �r '�;1''' s�l���+:'� \ter`{��t.tiL f`�,�'6d rt�y' f 5y`� . +` ±•\\ 1. .v,♦ ., �\ a � ._ I ,l�-y. r. _ + f a,'- ++jl�d\s ta1 � 's �a � -1.- 1 "�►y� - .v�♦ �,\ -• \ t `� ° �y.'4� �ti±� ,Y+ t' r",.. � , �, t \ !\� f aa. t♦� jit� ♦�a ���y° ����,:.w may. • - '.• _ i 'S,. a\ Y y,.+. .,� S tti T ,. i ,. .'•'. � y.• r °�•• h,y 1. 1 y \t° \.� �,at�� ���},.��+,ti�7'V^4:w - .' ; •,,1\.,,,\i a Y:S• `.,`v �.'°•` l£.,✓, ♦/•r'+ J♦• J.t f•� -` ''•r�ti\y',~'\�y�rjilu`�G�� y�1w 1�°v�4(,^,4i'•�~+v�A t ,. ,.. .. - ., . Y" °., r� ° t� I - _ ,!.. 1l• .1'i• ,l .� ti�T S,♦ �y�Z.:i µ,4�•L '��„�..>,. , • , .- ... '" ..- bat-4 ► - _ - �t. ��ti k1 .,�41 hf'\";l�'\yt .�t V.: 'i\ w,'���"���'•'3r „•^*4� • ! ♦v _ i # - _ t � S e r ��`•-� r= .;; • air, }; J r a/.;71 ;J•r ss N)���Y��f f, r� ` ' a r ♦ � Jea +► r , /#mot i of i drt I t re�'•i(i/k :TS , a �r � � i • Y 17 F Jf i►J`r} r�i7L 'S£ ii rifrylf rL kk .� - - J , dt.�2:�din'-'. rta ii "4 - - �`s'�an'��,_-:,�.4 '"1 � �' r -- - -- -- --`---_ _. _ _ - -- �. - - _ y_ ..- ,. • r_ � .- - - - _ nttrrl°}y"1 Srs,�y T` �r°rT" 'r•� J,� r `„ - J - -, .. , N , _ - � -�. - •a "j tar- '"`r"'►� �. f _�_ - y r ! ,. ♦ " a �t AC�® DATE(MMIDDIYYYY) CERTIFICATE OF LIABILITY INSURANCE 10/23/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the cgrtiflcate holder is an ADDITIONAL INSURED,the pollcy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Richie Szarkowicz NAME: SZARKOWICZ BROKERAGE LLC PHONE (718)389-0646 FAXNo: (718)389-0670 PO BOX 140736 ADDRESS: richie@szarkowiczgroup.com INSURERS AFFORDING COVERAGE NAIC# STATEN ISLAND NY 10314 INSURERA: Mesa Underwriters Specialty Ins Co 36838 INSURED -INSURERS: Palomar Excess and Surplus Ins Co 16754 KAMTECH RESTORATION CORP INSURER C: 203 SHERIDAN BLVD INSURER D: INSURER E: INWOOD NY 11096 INSURERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE ADDL SUER POLICY NUMBER MMIDDIYYYY FF MM/DD/EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 5�;] DAMAGE TO RENTEU-- CLAIMS-MADE F-J OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 A X X MP0082001008805 10/21/2024 10/21/2025 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $ 2,000,000 X POLICY❑JECOT- LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILEUABILITY COMBINED SINGLE LIMIT Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per eccIdent $ UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 2,000,000 B X EXCESSLIAB CLAIMS-MADE PES-XS-01-3097 10/21/2024 10/21/2025 AGGREGATE $ 2,000,000 DED I I RETENTION $ WORKERS COMPENSATION STATUTE ERH AND EMPLOYERS'LIABILITY Y I N ANYPROPRIETOR/PARTNERIEXECUTIVE ❑ NIA E.L.EACH ACCIDENT $ OFFICER/MEMBEREXCLUD�D7 (Mandatory In NH) E.L DISEASE-EA EMPLOYEE $ if es,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT S DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Certificate holder is Included as additional Insured with respect to CGL policy,Waiver of Subrogation included In the policy.Primary&Non-contributory wording included. CERTIFICATE HOLDER CANCELLATION Town of Southold Town Hall SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 53095 Route 25 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 Southold NY 11971 TIM RePREs (J 01988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) A A A A A A 465203149 SZARKOWICZ BROKERAGE LLC lie PO BOX 140736 . STATEN ISLAND NY 10314 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER KAMTECH RESTORATION CORP. D/B/A TOWN.'OF SOUTHOLD TOWN HALL KAMTECH SOLAR SOLUTIONS 53095 ROUTE 25 203 SHERIDAN BLVD SOUTHOLD NY 11971 INWOOD NY 11096 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE K2348 857-0 321533 11/22/2024 TO 11/22/2025 10/24/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2348 857-0, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/MIWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO.GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT(I OF 1 ) KRZYSZTOF KAMINSKI OF KAMTECH RESTORATION CORP. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND DIRECTORJNSURANCE FUND UNDERWRITING VALIDATION NUMBER: 396211666 U-26.3 <11TE, K workers' CERTIFICATE OF INSURANCE COVERAGE TE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family'Leave benefits carrier'or licensed insurance agent'of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b. Business Telephone Number of Insured KAMTECH RESTORATION CORP. 203 SHERIDAN BLVD 7189158360 INWOOD, NY 11096 Work Location of Insured(Only required it coverage is specifically limited to 2. Name and Address of Entity Requesting Proof of Coverage 3a, Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York Town of Southold Town Hall y p Y 53095 Route 25 3b: Policy Number of Entity Listed in Box 1 a Southold, NY 11971 L78513-000 3c.Policy Effective Period 12/1/2014 to 10/23/2025 4. Policy provides the following benefits: 0 A.Both disability and Paid Family Leave benefits. B.Disability benefits only. C.Paid Family Leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits.Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as descr' d above. Date Signed 10/24/2024 By W§A* o (Signature of Insurance carrier's authorl d representative or NYS licensed insurance agent of that Insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT:If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B, 4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4B,4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. hsurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) �I01111°°°1°1°1°1°°1°I11111°�!1!°�IIIII Additional Instructions for Form 1313-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage (Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on,a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first,two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b) The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. D13-120.1 (12-21)Reverse ^6000NT #: 9624516002 METER #: 98300586 Z o _ a • w i— — — — — z ! TO UTILITY (E) 120/240V AC 120/240V w SINGLE PHASE SERVICE ROOF(}!�BASEMENT 1 ' unun METER Y (1)RED#12 AWG PV CABLE, (1)RED#12 AWG THWN-2, EXTERIOR WALL J (1)BLACK#12 AWG PV CABLE, (1)BLACK#12 AWG THWN-2, ---- — — ----- — — — — — o— — 0 - v #6 AWG BARE CU GND (1)GRN#8 AWG THWN-2 GND UNE , u N BASEMENT Y IN 1"MIN. RMC �Orn IQ COMBINER BOX 4/4C (E) QO LOAD CENTER Q p z SYSTEM SIZE:4.14KW DC, 3.42KW AC COMBINER BOX#1 / C 200A MAIN PANEL ?Y (9)REG REC460AA PURE-RXMODULES SOLADECK 0786-41 \ \ 200A MAIN BREAKER Y?O (9) ENPHASE IQ8X-80-M-US MICROINVERTER GATEWAY _ 20A BACKFEED BREAKER kj 15A z"U STRING 1: (9) — _ — — NEUTRAL w PANELS/STRING °M+ w+ w- w+ av w+ w• 2OA LOAD�� BUS N wwimous IRREVERSIBLE CRIMP _ "�' W 0 GROUND m BUS V7 z (1)RED#10 AWG THWN-2, FACILITY O j (1)BLK#10 AWG THWN-2, GROUND - (1)WHITE#10 AWG THWN-2, E- (9)REC REC460AA PURE-RX (9) ENPHASE IQ8X-80-M-US WEATHER INFO ; (1)GRN#8 AWG THWN-2 GND MODULES MICROINVERTER ! IN 3/4"MIN. EMT 41 -1 Zip Code 11935 0 Pmax 460W Peak output power 384 VA Max Average i N High 31°C/87.8°F Voltage at Max Power Maximum continuous o: 54.90 V 380 VA (V)Vmp: output power Record High 340C/93.20F 0a Current at Max Power Maximum continuous 1.58A Record Low - ° ° ELECTRICAL NOTES -' A Imp: 8.38 A output current 15 C/5.0 F a� O 0 Open Circuit Voltage(VOC) 65.30 V Nominal frequency 60 Hz 1. ALL CONDUCTORS ARE COPPER UNLESS NOTED OTHERWISE. Short Circuit Current B 88 A Maximum units per 20 l0 (A) Isc A(L-L)branch circuit 2. AC & DC GROUNDING CONDUCTORS PER NEC ARTICLE 690.47(c)(2) CONNECTED AS PER 250.64(c)(1) System voltage 1000 V CEC Efficiency 96.5% 3. ALL EXTERIOR MOUNTED COMBINERS, ]UNCTION BOXES, TROUGHS, DISCONNECTS, ETC.-SHALL BE MIN. NEMA 3R RATED. DARC 4. CT'S TO BE LOCATED BETWEEN THE MAIN BREAKER AND THE LINE SIDE TAP. LABELS ON THE CT SHOULD BE FACING THE TAP. 1es+T -1 OF N PAGE NAME: THREE LINE DIAGRAM DWG NO: INSTALL NO: PV-7 DESIGNER: OO BY: SYSTEM SIZE: DATE: 4.14 KW 10/712024 t 1 APP 06EDAS NOTED.p FEE ' U BY. AWIFY BUILDING DEPARTMENT AT 431.788.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS; t. FOUNDATION-TW(-,-?F-' FOR POURED 00m.u 2. ROUGH-Fn- Amii�G r & INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON•ERRORS INSPECTION REQUIRED COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND C NDITIONS OF SOUTH' TOWN ZBA SOUTH TOWN PLANNING BOARD ___SO OLD TOWN TRUSTEES ._..N, , ,DEC UTHOLD HPC SCHD OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY Chun Feng, RA 409 Jackson Ave Twp of Washington,NJ 07676 (201) 638 5851 Date: August 22, 2024 Building Official Building Department CUTCHOGUE, NY Re: Solar panel installation at 310 DUCK POND RD CUTCHOGUE,NY, 11935 . To whom it may concern, Solar panels,installation is being proposed at the above-mentioned address. I am retained by Kamtech Solar to verify that the existing building structure, after the addition of the solar panels, is still adequate to sustain the effects of the wind load as well as all other loads for which the buildings are designed for. The pitch of the existing main flat roofs is about 15 degrees with 2x10 rafters at 1.6" on center. The longest existing rafter span is.about 21'. REC REC460AA PURE-RX (460W) Modules are to be installed. Each solar panel has dimensions of about 68"x 47.4" xl.6" and weighs approximately 50 lb. each. The supporting racking system is Solar Mount by UniRac located at 1411 Broadway Boulevard NE Albuquerque NM 87102. After the field survey and the examination of the catalogues of both the panel manufacturer and supporting racking manufacturer, I.hereby certify that the small increase in load on the roof and its supporting structure due to the installation of the solar panels is acceptable. The existing building structure is adequate to sustain the effects of the wind load as well as all other loads for which-the buildings are designed for with the installation of the solar panels provided the following are met: 1. Each module will be securely fastened ai a,minimum of 4 points (7mm x 11.5mm) using Solar Mount by UniRac. That is at least two points along each long side of the panel. It is important that the clip'centerlines are between 1/4 and 3/4 from the end of the module. 2. All fasteners shall be stainless steel or galvanized steel and other components of the racking system shall be made of galvanized or stainless steel or aluminum; 3. Follow manufacture mounting instruction strictly. 4. Stainless lag bolts shall be used,to fasten the racking,system-to the roof rafters and they need to be minimum 5/16". shaft and 3 1/2" long. 5. Lag bolts spacing shall be no more than 64" O.C. along the direction of the racking system. Lag bolts should be installed staggered, that is the lag bolts at every other rail should be staggered by 24" so they are fastened into alternating rafters. 6. Thread must be embedded in the side grain of a rafter. 7. Lag bolts must be in the middle third of the structural member. 8. Install lag bolts with head and washer flush to surface. Do not over-torque. 9. Proper waterproofing and proper sealant shall be_applied at every penetration. Roof structure is reviewed for adequacy and code compliance as.per.the requirement of 2020 Residential Code adapted by New York State and the provision of ASCE 7-16. The following design load criteria were used: Ground,Snow Load: 20 psf; Wind Speed: 130 mph; Exposure:..B; Important factor: 1. This architect is responsible for certifying that'the proposed structure is sufficient for resisting wind uplift and down force load only. Any other aspect of the project including but not limited to component defects,'leakage; system malfunction, system performance, etc. are not the responsibility of the undersigned. If you have any question, please do not hesitate.to contact me at (201) 638 5851. Thank you Truly yours, Chun eng, RA \SJjEREQ ARC UN F��, 9T '951.7 �- FUFNEIO � STRUCTURAL CALCULATIONS FOR 310 DUCK POND RD CUTCHOGUE, NY, 11935 Support of A New Rooftop Photovoltaic System Prepared by Chun Feng, RA 409 Jackson Ave Twp of Washington, NJ 07676 NJ License#: 11044 NY License#: 019517 22-Oct-24 Design Load Criteria: Ground Snow Load Pg: 20 PSF Sloped Roof Snow Load Pf: 0. 7(20) (1. 1)= 15.4 psf Design Wind Speed: 130 MPH Exposure: B Important Factor I: 1. 0 Main House Check Roof Rafters Rafter Span: 21' Fb' = 850 (1. 15) (l. 15) (1. 2) = 1, 349 PSI Sx (2x10) : 21. 39 in. M = Fb'*Sx = 1, 349*21. 39/12= 2. 4 k-ft W = M*8*1, 000/L*L= 43. 54 PLF 43. 54 x 12/16= 32. 65 PSF ok As per ASCE7, Method 1: Pnet30 = 10. 5 psf Total Design Load Case Formula Result, psf Max, psf Case 1 1. 01) + 1.OS 18. 9 Case 2 1. OD + 1. OPnet (down) 14 Case 3 1. OD + 0. 75S + 1. OPnet (down) 25. 55 25. 55 plf << 32. 65 plf OK Check Wind Uplift ASCE 7. 05 Method 1 Component + Cladding Wind Specifications Ps = A*Kzt*I*P30 S�ERED q�, V=130 mph Kzt=1.0 Ps = 1.0(1. 0) 0. 0)*P30 v� G UN F cy Exp. B I=1. 0 Ps = 1. 0*P30 Q� H F'y0 ��� A= 1. 0 L = 15 a=20 sf '9 '079517 Zone Downward Uplift 3 8. 9 —40. 2 psf Panel Area REC REC460AA PURE—RX (460W) MODULE DIMENSIONS = 68. 1"X 44" = 20. 81 SF Wt = 47.4 # 47.4/20. 81 :2. 28 psf Racking (Solar Mount Rails) 1. 0 psf 3. 28 psf Total Weight: 68. 3/ panel Check Fasteners LL = 0. 6D + Wind 0. 6(68. 3#) + —40. 2 x 20. 81 equals —795. 6 —38. 2 psf (net) Mounting: 2 Horizontal Rails per Horizontal Row of Panels Fasteners @ 48" o. c. Max. Contributing area per fastener = 1/2 (68. 1/12) (48/12) = li. 35 sf Fup: 11. 35 x —38. 2 equals —433. 57 (net) Fastener 5/16 x 4. 5" long* 3" penetration x 235 #/in. = 705#/lag ok * Use Stainless Steel Lag Bolts PROJECT DESCRIPTION: , w (9) REC REC460AA PURE-RX(460W)MODULES '1 s � (9)ENPHASE IQ8X-80-M-US MICROINVERTER ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES z SYSTEM SIZE:4.14KW DC STC, 3.42KW AC J T \ a ILI J fir. A W J J C �J C Y J 0 J ) J T Of ,o ��, � 2 HOUSE PHOTO F-o GROUND �U� t PV-1 SCALE: NTS p z ACCESS 0 w T N GROUND J J t ��+V N ACCESS o 310 Duck Pond Rd, %j — (N) COMBINER BOX(BASEMENT) Cutchoit ue,NY ►- (E) UTILITY METER (OUTSIDE) 2j'O 11935,Uned States o� J (E) MAIN SERVICE PANEL(BASEMENT) j Euge O E ix �N� N � � d VICINITY MAP PV-1 SCALE: NTS O y V \ j c GROUND ACCESS APPLICABLE CODES&STANDARDS il, C J 2020 RESIDENTIAL CODE OF NEW YORK STATE(RCNYS) 2-STORY HOUSE NATIONAL ELECTRICAL CODE(NFPA70)12017 eD q RC V� ��� ►�� ��N FF TO THE BEST OF KNOWLEDGE,BELIEF,AND PROFESSIONAL x / I 1 ROOF#1 JUDGMENT OF THE UNDERSIGNED,THE PLANS AND SPECIFICATIONS � Ov� \ �^ (9) MODULES DEPICTED ON THESE DRAWINGS ARE IN COMPLIANCE WITH THE APPLICABLE PROVISIONS OF THE 2020 NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE AND ALL SUPPLEMENTS. GROUND OmN ACCESS PAGE NAME: tO f14�1i PLOT PLAN S \ V / DWG NO: INSTALL NO: \ PV-1 PLOT PLAN WITH ROOF PLAN DESIGNER OCBY NON-HABITABLE SYSTEM SIZE: DATE: PV-1 SCALE: 1/32"= l'-O" STRUCTURE "KW 10/22/2024 MODULE TYPE, DIMENSIONS & WEIGHT € � W NUMBER OF MODULES=9 MODULES ARRAY AREA CALC'S MODULE TYPE=REC REC460AA PURE-RX(460W)MODULE �� TOTAL PERCENTAGE s. ARRAY AREA OF ROOF WEIGHT=50.0 LBS/22.68 KG. GROUND o ro. #OF ROOF ARRAY MODULES AREA AREA COVERED BY MODULE DIMENSIONS=68.0"X 47.4"=22.38 SF ACCESS (Sq.Ft.) SOLAR ARRAY (Sq.Ft.) UNIT WEIGHT OF ARRAY=2.23 PSF o (%) o ROOF VENTS,SKYLIGHTS, Q��� #1 9 201.42 364.25 55.30 WILL NOT BE COVERED 2 w UPON PV INSTALLATION o c�- D) Lli ARRAY DESCRIPTION ARRAY TYPE x ARRAY ARRAY AZIMUTH TILT #1 15' 127' Y J 0 A. A Y L0 q� o m Q O a z o Y O 0 �oU O 3,Q Q . Z LU GROUND �X3 w 0 o. ACCESS GROUND m N ACCESS Z F- o (N) COMBINER BOX(BASEMENT) 9. J (E) UTILITY METER(OUTSIDE) 2-STORY HOUSE In In (E) MAIN SERVICE PANEL(BASEMENT) Em mQ ,9 �' J O s Q. 9� a ^'3 ROOF#1 ^ 'o, ^y» (9)MODULES U. 3� 0 GROUND RED AR ACCESS JN FF,�,Oy�� N ^,��'� LEGEND X 'V A uM -UTILITY METER s� Q� Eil -B ;r °ree+i t 3, o CB -SUB PANEL PAGE NAME NEN GROUND MsP -MAIN SERVICE PANEL ROOF PLAN s ACCESS DWG NO INSTALL N -VENT,ATTIC FAN(ROOF OBSTRUCTION) PV-2 1 ROOF PLAN & MODULES 0 -PV MODULES DESIGNER: DC BY SYSTEM SIZE: DATE: PV-2 SCALE:3/32"=V-0" -BUILDING OUTLINE 4.14KW IOr22/20z4 ROOF TOP MODULE LAYOUT PLAN EXISTING RAFTERS ROOF JOIST REC MODULE DETAILS AND RAIL MOUNTING ALLOWANCE STANDARDS 1 SCALE:3/16" = 1'-0" ROOF AZIMUTH TILT 3 Z Z X1 O @ 16 O.C. SIZE & SPACING SCALE:5" = 1'-O" W SOUTH-EAST AZIMUTH: 127' 18" FIREPATH SOUTH-EAST 1270 150 2"X10" @ 16" O.0 2'(5 cm 14'(35.5 cm 14'(35.5 cm '(5 cm) PITCH: 15' - ao' I r 2-(5 cm) 2'(5 cm) OZ I I I I I I I I I 14'(35I.5 cm 14'(35.5 cm) I I I I I I I I I o I I I o I I I . CHIMNEY i I I VA I I I I I I I I I Q Nr) _ N Y Z J O rn I I I I I I I I I Y Lo co I I I I I I I I I FL m I I I I I I I I I 14'(35.5 cm 4'(35.5 cm) < 0 Z 0 CL W .r.� I I I I I I I 2'(5 cm 2'S cm) _ Y0o a0 I 2'(5 cm 14'(35.5 cm 14-(35.5 em -(5 cm) Q U Z INVISIMOUNT RAIL MOUNTING ALLOWANCE STANDARDS FOR 96 CELL MODU_E W RAILS MAYBE POSITIONED IN THE NON-CROSSHATCHING N 12�-0�� - REGIONS ONLY.RAILS MAY BE POSITIONED A MINIMUM OF 2"(5cm)BUT m 1 NOT MORE THAN 16"(40.6cm)FROM ANY MODULE CORNER. NOTE:MAXIMUM ARRAY WIDTH IS 40'(12.2m).TO INSTALL ADDITIONAL MODULES BEYOND THIS MAXIMUM INSTALLER MUST 2 0 2 SECTION-CONSTRUCTION CONNECTION DETAILS BEGIN A NEW ARRAY.MINIMUM DISTANCE BETWEEN ARRAYS IS 2"(5CM). V - SCALE:1/4" = 1._U" STRUCTURAL NOTES: 4)_ m, LEGEND .�■ o 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. 0 -PV MODULES -BUILDING OUTLINE 2. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE Ix -VENT,ATTIC FAN STRUCTURE DURING CONSTRUCTION.THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE g M a (ROOF OBSTRUCTION) CONTRACTOR'S MEANS, METHODS,TECHNIQUES,SEQUENCES FOR THE PROCEDURE OF %oo 0 -ROOF ATTACHMENT CONSTRUCTION,OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO. o �� y - RAIL ��� 1�Sa THE EXISTING ROOF STRUCTURAL MEMBERS WITHOUT ADDITIONAL REINFORCEMENT ARE -RAFTERS ADEQUATE TO SUPPORT THE LIVE,SNOW,AND WIND CESIGN LOADS REQUIRED BY THE -T-0" FIRE ��� �� I BUILDING CODE IN ADDITION TO THE EXISTING DEAD LOAD AND THE SELF-WEIGHT OF THE PV PATH SETBACK 231-ro MODULES AND MOUNT RAIL SYSTEM AS SHOWN ON THESE DRAWINGS. 4. THE STRUCTURAL ANALYSIS WAS PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND THE ASCE 7-10 STANDARD,BASED ON THE FOLLOWING DESIGN CRITERIA: EKED ARc N Feh titer GROUND SNOW LOAD = 20 PSF I I �° BASIC WIND SPEED = 130 MPH(RISK CATEGORY II) - - - - - - -I E. THE 5/16"0 STAINLESS STEEL HEX LAG SCREWS 4"LONG WITH A 2112"MIN.EMBEDMENT °F N 1 — — — — — — — -- — —— — — — — — — — — — — — — — — _ — PAGE NAME. INTO CENTER OF RAFTERS ARE ADEQUATE TO SUPPORT THE MAXIMUM WIND UPLIFT DESIGN ROOF PLAN - I LOAD ACTING ON THE MODULES.PROVIDE CHEMLINK M-1 SEALANT OR APPROVED EQUAL DWG NO INSTALL NO AT LAG SCREWS PENETRATION POINTS. PV-3 DESIGNER: OC BY 6. PV MOUNTING SYSTEM TO ATTACH PANELS TO ROOF STRUCTURE TO BE INVISIMOUNT RAIL MOUNTING SYSTEM BY REC.INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SYSTEM Size DATE 4.14 KW 10/22/2024 a E a w PV MODULES o a SEE (2/PV-4) FOR ENLARGED o VIEW z 2 D w w HERS @,6 pG _Y J Y Lo Qom FL Q°z} maw PV MODULE Y 0 o 0 o U U 1 ATTACHMENT DETAIL SNAPNRACK CHANNEL NUT w N PV-4 SCALE:NTS END CLAMP 5/16 X 1" S.S. BOLT AND SPLIT WASHER z m 0 SNAPNRACK COMPOSITION L-FOOT CAN BE MOUNTED z IN ANY ORIENTATION SNAPNRACK STANDARD RAIL 5/16 S.S. FLANGE NUT D SNAPNRACK COMPOSITION ROOF FLASHING 4i o E N a SNAPNRACK L FOOT BASE m o — 5/16" S.S. LAG SCREW WITH FLAT WASHER 2.5" MINIMUM EMBEDMENT IS STANDARD EDA c SEAL PENETRATION AND 2'X10 �,c,�4Nu Fyoy.� UNDER BASE WITH /vIr -, APPROPRIATE ROOF SEALANT �'9T 1a51T FOP NEN� PAGE NAME. MOUNTING DETAILS DWG NO- INSTALL NO: PV-4 2 ATTACHMENT DETAIL (ENLARGED VIEW) DESIGNER: OC BY PV-4 SCALE:NTS SYSTEM SIZE: DATE: 4.14 KW 10/22/2024 SYSTEM LABELS: W WARNING - DUAL POWER SOURCE 0 WARNING o INVERTER OUTPUT CONNECTION. DO NOT a a_ SECOND SOURCE IS PV SYSTEM RELOCATE THIS OVERCURRENT DEVICE. 0 v ri) e LABEL LOCATION:(MP) ITEM#596-00231 LABEL LOCATION:(POI) ITEM#596-00589 LU PER CODE:NEC 705(D)(3)(4) PER CODE:NEC 705.12(D)(3)(4) CAUTION 0 N o PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER TO THIS BUILDING IS ALSO > MAXIMUM AC OPERATING CURRENT: POWER SOURCE SUPPLIED FROM THE FOLLOWING NOMINAL OPERATING AC VOLTAGE: EH E] LABEL LOCATION:(C)EVERY 10' ITEM#596-00206 SOURCES WITH DISCONNECTS AS SHOWN PER CODE:NEC 690.31(E)(3) LABEL LOCATION:(ACD) ITEM#596-00239 PER CODE:NEC 690.54 Q WARNING A^N'N INVERTER OUTPUT CONNECTION. DO PHOTOVOLTAIC SYSTEM NOT INVERTER EQUIPPED WITH RELOCATE THIS OVERCURRENT Y LABEL LOCATION:(D)NEXT T ITEM#596-00589 LO RAPID SHUTDOWN PER CODE NEC 705.12(D)(3)(4) LABEL LOCATION:(M) ITEM#596-00677 PARALLEL GENERATION SOURCE: Q o Z PER CODE:NEC 690.56(C),MUST BE REFLECTIVE a-' PHOTOVOLTAIC SYSTEM D Y Y�o &WARNING UTILITY SERVICE DISCONNECT LOCATED: U)oU N/A Z Are Flash Hazard Appropriate PPE required PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED: COMBINER BOX N Failure to comply can result NORTH-WEST UTILITY METER 3 m in death or injury MAIN SERVICE PANEL ° Refer to NFPA 70E 690.15(A)4,690.5(B),705.10 v1 110.1s am Z &WARNING SOLAR ARRAY 0 SERVICE DISCONNECT 1 0F 2 ELECTRICAL SHOCK HAZARD ~ DO NOT TOUCH TERMINALS. J 225.37,230.2(E) TERMINALS ON BOTH THE LINE AND O LOAD SIDES MAY BE ENERGIZED IN VI OTHER DISCONNECT LOCATED: THE OPEN POSITION 310 DUCK POND RD, CUTCHOGUE, NY 11935 o a 225.37,230.2(E) ' r . • . • ' z 100 0 V N III This equipment is fed by multiple sources. POWER SOURCE Source:1 690.31(G)3&4,690.31(G)1 �i WARNING Utility Grid - Main service panel &WARNING INVERTER OUTPUT CONNECTION in 1 st floor. DO NOT RELOCATE THIS OVERCURRENT DEVICE Source 2: ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS 705.12(D)2(3)b VN��ify FP Photovoltaic system - Disconnect on PHOTOVOLTAIC SYSTEM ARE O��4� ►p UNDERGROUNDEDANDENERGIZED NORTH-WEST wall of house ! WARNING 690.35(F) 226.37,230.2(E),705.12(D)3 THIS EQUIPMENT FED BY MULTIPLE SOURCES. sl, Q'F ,' &WARNING PHOTOVOLTAIC TOTAL RATING OF ALL OVERCURRENT DEVICES, 9'�OF N y EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, WITH SHALL NOT EXCEED AMPACITY OF BUSS BAR PAGE NAME. EQUIPPEDr , SYSTEM LABELS ELECTRICAL SHOCK HAZARD DWG NO: INSTALL NO: IFA GROUND FAULT IS INDICATED, [RAPID ,• PV-5 NORMALLY GROUNDED CONDUCTORS DESIGNER: OC 8Y: MAY BE UNDERGROUNDED AND ENERGIZED SYSTEM SIZE: DATE: 4.14 KW 10/22/2024 f. . Rai a a W SOLAR'S MOST TRUSTED REC as DATASHEET ,OL�'R',MOST TRUSTED Maasuran•ms In Inches W GENERAL DATA 0 izs z ® Cell T e 88 half-cut bifacial REC he.erojunctioncells, 0 YP withgapiess technology D REE ALPHA0.13 in.solar lass with anti-reflective surface treatment > Glass g W inaccordancewithEN1215D Backsheet Highly resistant polymer(Black) "9 j a69 Frame Anodized aluminum(Black) PURE-RX 5ERIE5 4-part,4 bypass diodes, a + # Junction Box IP68rated,inaccordancewithlEC62790 f � StSubliMC4PV-KBT4/KST4(12AWG) C Connectors - + E in accordance with IEC 6285Z IP68only when connected _Y Cable 12AWG solar cable,66.9 in.*66.9in. I J in accordance with EN50618 O DATA5HEET Dimensions 68x47.4x1.2irt.(22.4ft2) a'' Weight SOlbs ...to era' .... :.aanz 1 0 02 Origin Made in Singapore ; o ELECTRICAL DATA PRODUCT CODE-:RECxxxAA Pure-RX CERTIFICATIONS g d Lli Power Output-P (W,J 450 460 470 IEC 61215:2021;IEC617303016;UL61730 m V Watt Class Sorting-(W) 0/•10 0/+10 0/t10 150119252 Ignitability(EN 13501-1 Class E) o Y O U IEC62716 Ammonia Resistance o U Nominal Power Voltage-V,,n,(V) 54.3 54.9 55.4 IEC61701 SaltMist(SM6) ch • Nominal Power Current-I_(A) 8.29 8.38 8.49 IEC61215:2016 Hailstone(35mm) Z U UL 61730 Fire Type 2 • N Open Circuit Voltage-V,,,(V) 65.1 65.3 65.6 ISO 14001;1509001;IEC45001;IEC62941 W Short Circuit Current-I,(A) BAI age 8.95 c �� O Power Density(W/ftz) 20.1 20.5 21.0 R OW C E F51 ,n m Panel Efficiency(%) 21.6 22.1 22.6 o.ancrx ua..w,rv . r�a.nrwa. to z Power Output-P_(W,) 343 350 358 0 I- Nominal Power Voltage-VMeP(V) 51.2 51.7 52.2 • �� �� F Z Nominal Power Current-IMeP(A) 6.70 6.77 6.86 EOMPATIBLE WITH MLPE Open Circuit Voltage-V,(V) 61.3 61,6 618 Short Circuit Current-I,r(A) 7.11 7.17 7.23 WARRANTY 0 Values a: .,,lord test amdt (TC. a� AMIS'rradiance 100(IW/m�,temperature77•F(75°QL based one prodoRianspread-h.taleranceofP V &1,13% Standard REC Pro Trust (n w4hmorewattclass.Nominalrtgdukope tit peatwe(NMpiaumass Am)S.irradarce80CN;>a,temperature58'F(20°Clwindspeed3.3k/s(1rryl;'Wherezxz Installed by an REC E IX mdkatea the nom tpo (R_h,151C ab Certified Professional No Yes Yes MAXIMUM RATINGS' TEMPERATURE RATINGS System Size All c25 kW 25-500 kW p Q Operational Temperature 40'F-185'F Nominal Module Operating Product Warranty(yrs) 20 25 25 M J System Voltage 1000V Temperature 44'C±2'C Power Warranty(yrs) 25 25 25 0 Maximum Test Load(front) +7000 Pa(1461b/ftz) Labor Warranty(yrs) 0 25 TO `t ` YEAR Temperature coefficient of P,c,x -D.24%/K c Maximum Test Load(rear) -4000 Pa(83.4lb/ftz) 'emperature coefficient of V� -0.24%/K Power in Year 1 98% 98%25 98% N .a Max Series Fuse Rating 25A Temperature coefficient of Ix 0.04%/K Annual Degradation 0.25% 0.2S% 0.2S% `t: WARRANTY Max Reverse Current 25A It 11Ie,,p,,,.,e,ek,,«rt:,tatedaret„aa,-lues power in Year 25 92% 92% 92% a 'See ir,hllabonnwnval For mount huttions. 2' ,.. Des�bad•Test load/I:�fery fa<ta) Tht,REC Rolrvst W ry aiy available on panels purchased ihnugh an REC oF (, DELIVERY INFORMATION �faedd5 a ore=ions i a.e wart ry „r apply, w. Vwp c .sea ' `3.. Panels per Pallet 33 an can s .r 09 Panels per 40 ft GP/high k ant i cube container 594(18Pallets) JOW LIGHT BEHAVIOR a ..x Panels per 53 ft truck 792(24 Pallets) p Available from: Typical low it performance of modul e at 5TC' q��%N F R? y - - ! r d er •I. Ir to915 k IV€S +.... �._�� _ .. . ix f. 1}„5,G_'-(� J r •' +� 7a ;'r"'P+ . . -. .... ') ` Ined-lw/m PAGE NAME ` Founded in 19%.REC Grow Is an international ioneerin solarener cum an dedicated to em owed consumers with clean affordable REC Solar M.LTD. p P s gv P v P ns an 20 Tuas South Ave.14 REC SPEC SHEET '•` '*� sJ`� _ _ ` .y�;,''i. eta solar power.As Solat's Most Trusted,REC is committed to high quality,irxwvatim.aid a low carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America Singapore 637312 ;e. REC" Europe. DWG NO INSTALL NO: wwwre+ pe,andAsia-Pacific. ecgroup.com wwwrecgroup.com PV-6 '-. .•.,. �f - :'�fi.'r"`.-«.,, �.•�..: ... «. ^„sE'... Ms>� .� DESIGNER: DC BY: -- SYSTEM SIZE: DATE: 4.14 KW 10122/2024 a W a % ENPHASE IQ8X Microinverter o INPUT n t :r a Commonly used module pairings w 320-540 U 1 To meet compatibility.PV modules must be within the following maximum input DC voltage and maximurn module I W Module compatibility - Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator O Z MPPT voltage range v 43-60 O U) Operating range v 25-79.5 > W Minimum and maximum start voltage V 30-79.5 Maximum input DC voltage V 79.5 Maximum continuous operating DC current A 10 # Maximum input DC short-circuit current A 16 Maximum module I, A 13 Y J Overvoltage class DC port - II NoN DC port backfeed current mA 0 L.L Y PV array configuration _ Ungrounded array;no additional DC side protection required;AC side protection requires a maximum of 20 A per 1 O branch circuit OUTPUT n Z}N a W Peak output power VA 384 366 y U(� Maximum continuous output power VA 380 360 Y 0 O 2 Q8X M i e ro i n ve rte r Nominal grid voltage(L-L) V 240,split-phase(L-L).180' 208.single-phase(L-L),120"` _o U Easy to install Q Minimum and maximum grid votage' V 211-264 183-229 Z U Our newest I08 Series Microinverters are the industry's first microg rid-forming'.software-defined Lightweight and compact with plug and-play connectors Max.continuous output current A 1.58 1.73 W microinverters with split-phase power conversion capability to convert DC power to AC power N efficiently.The brain of the semiconductor-based microinverter is our proprietary application- Power line communication(PLC) Nominal frequency NZ 60 o specific integrated circuit(ASIC).which enables the microinverter to operate in grid tied or between components u • Extended frequency range Hz 47-68 m off-grid mode.This chip is built using advanced 55-nm technology with high-speed digital logic Faster installation with simple two-wire and superfast response times to changing loads and grid events,alleviating constraints on battery cabling AC short circuit fault current over three cycles Arms 2.70 to sizing for home energy systems. Maximum units per 20 A(L-L)branch circuit 3 - 10 9 Z High productivity and reliability O I08A Microinverter is the latest addition to this family,designed to support PV modules with high 9 Total harmonic distortion °b <5 output DC voltage and cell counts.such as 80-half-cut cells.88-half-cut cells and 96-cells. Produces power even when the grid is down' Overvoltage class AC port More than one million cumulative hours • of testing AC port backfeed current mA 18 J 25 Class II double-insulated enclosure Power factor setting - 1.0 O Optimized for the latest high-powered PV modules Grid-tied power factor(adjustable) - 0.65leading...0.851agging Part of the Enphase Energy System, I08 Series Microinverters redefine Peak efficiency % 97.3 97.0 o Q IG8 Series Microinverters integrate with reliability standards with more than one Microgrid-forming 9 Y CEC weighted efficiency 'k 96.5 96.5 the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Complies with the latest advanced grid O Enphase App monitoring and analysis testing,enabling an industry-leading support Nighttime power consumption mw 26 12 0 software. limited warranty of up to 25 years. Remote automatic updates for the MECHANICAL DATA latest grid requirements • Configurable to support a wide range Ambient temperature range -401C to 65°C(-40°F to 149'F) of grid profiles Relative humidity range 4%to 100`a(condensing) Meets CA Rule 21(UL 1741-SA)and IEEE 1547:2018(UL 1741-SB) DC connector type Staubli MC4 CERTIFIED Dimensions(H•W•D);Weight 212 mm WY)-175 mm(6.9")-30.2 mm(1.2"1:1.1 kg(2.43lb) NOTE: Cooling Natural convection-no fans Connect PV modules quickly and easily I08 Series Microinverters are UL Listed 108Series Microinverters cannot be mixed with Approved for wet locations;Pollution d RED AID to the I08 Series Microinverters with as PV rapid shutdown equipment and previous generations of Enphase microinverters(107 degree Yes;PD3 ��W)N lir C Integrated MC4 connectors. conform with regulations when installed Series.106 Series,and so on)it the same system. Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure �\ G �n according l0 the manufacturer's IQ Microinverters ship with default settings that '( instructions. meet North America's IEEE 1547 interconnection Environmental category:UV exposure rating NEMA Type 6;outdoor standard requirements.Region-specific n AT adjustments may be requested by an Authority Having Junsdiction LAW)or uti ity representative. CA Rule 21(UL 1741-SA).UL 62109-1.IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01. OF N accwdmg to the IEEE 1547 interconnection Certifications This product is UL Listed as PV rapid 'Meets UL 1741 only when installed with 10 Systar-Controller 2 or 3. p p oi shutdown equipment and conforms with NEC 2014,NEC 2017.NEC 2020,and NEC 2023 section 690.12 and standard.An 10 Gateway is required to make these C22.1-2078 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. PAGE NAME. changes during installation. SPEC SHEET O 2024 En E (1)No enforced DC/AC ratio. Enphase Energy.All ripMsreeervad.Enphase.the and CC and certain other marks listed at (2)Nominal voltage range can be emended beyond nominal if required by the utility. DWG NO INSTALL NO: httos://enphaw.com/tradannark-usage-ouldeXnes are trademarks of Enphase Energy,Inc.n the U.S.and other countries. (3)Limits may vary.Refer to local requirements to define the number of microlm•e,ters per branch in your area. Daa subject to charge. 108X-MC4-DSH-00185-3.0-EN-OS-2024-02-12 (4)IQ8X is not certified for use with Enphase Three Phase Network Protection Relay(NPR-3P-208-NA)and is.therefore.desicred 108X-MC4-DSH-00185-3.0-EN-US-2024-02-12 PV-6.1 for single-phase operation only.C Mack writ the kcal utility requirements if yo4 wish to install single-phase inverters across three phases. DESIGNER: Oc BY: SYSTEM SIZE: DATE: 4.14 KW 10/22/2024 a w ENPHASE IQ Combiner 4/4C Z 0 MODEL NUMBER UNITS DESCRIPTION F_ _a IQ Combiner 4 with an IQ Gatewa:y printed circuit board for integrated revenue-grade PV production W IQ Combiner 4 Q (X-IQ-AM7-240-4,X2-IQ-AMt-240-4) - metering(ANSIC12.20!0.5%)andconsumptionmonitoring(2.5%),Includesasilversolarshieldtomatch W the IQ Battery and IQ System Controller 2 and to deflect heat. p s IQ Combiner 4C with an IQ Gateway printed circuit board for integrated revenue-grade PV production Z0 metering(ANSI C12.20tO.5%)and consumption monitoring(s2.5%).Includes Enphase Mobile Connect W f _ `3 ENPHASE '. IQ Combiner 4C cellular cellular modem(CELLMODEM-Adl-O6-SP-OS),aplug-and-play industrial-grade cell mcdemfor systemsW (X-10-AM1-240-4C.X2-IQ-AMl-240-4C) upto6Omicroinverters.(Available inthe US.Canada.Mexico.Puerto Rico.and the US Virgin Islands. � where there is adequate cellular service in the installation area).Includes a silver solar shield to match the IQ Battery and IQ System Control-er 2 and to deflect heat. WHAT'S IN THE BOX UNITSXk 10 Gateway is the platform for total energy management for comprehensive,remote maintenance.and 10 Gateway printed circuit board X-+Q-AM1-240-4 management of the Enphase Energy System. Y X2-IQ-AM1-240-4 Busbar 80 A busbar with support for one 10 Gateway breaker and four 20 A breaker for installing J IQ Series Microinverters and 10 Battery O (IEEE 1547:2018) X-1Q-AM1-240-41C IQ Gateway breaker A Circuit breaker,2-pole,10/15 Production CT - Pre-wired revenue-grade solid-core CT.accurate up to z0.5% Y co uo ....._ X2-I0-AM1-240-4C ' � (IEEE 1547:2018) Consumption CT - Two consumption metering split core or clamp-type CTs,shipped with the box,accurate up to 2.5% �W Qz} Emphase Mobile Connect(only with 10 Combiner 4C) - 4G-based LTE-Mt cellular modem(CELLMODEM-MI-06-SP-05)with a five-year T-Mobile data plan N 0 Z O_W MICROINVERTERS,ACCESSORIESAND REPLACEMENT UNITS PARTS!not included:order separatetyl IQ Combiner 4/4C Y//�,°0 Supported microinverters IQ6.IQ7,and IQB.Do not mix Microinverters with IQ8 v/O V Smart Includes IQ Gateway for communication Enphase Communications Kit Q V The Enphase IQ Combiner 4/4C with IQ Gateway and integrated LTE M1 cell modem and control COMMS-CELLMODEM-Mt-06 Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with a 5-year Sprint data plan for Z (included only with IQ Combiner 4C)consolidates interconnection equipment into a - Enphase sites (jJ Includes Enphase Mobile Connect cellular single enclosure and streamlines IQ Microinverters and storage installations by providing a CELLMODEM-Mt-06-SP-05 -4G-based LTE-Mt cellular modem with a five-year Sprint data plan N modem(CELLMODEM-Mt-O6-SP-O5). o consistent.pre-wired solution for residential applications.It offers up to four 2-pole input CELLMODEM-M7-06-AT-05 4G-based LTE-M1 cellular modem with alive-year AT&T data plan w included only with IQ Combiner 4C circuits and an Eaton BR series bulbar assembly. • Includes solar shield to match IQ Battery Supports Eaton BR2xx,Siemens Q2xx and GE/ABB THQL21xx Series breakers(xx may be 10.15.20, o m aesthetics and deflect heat Circuit breakers(off-the-shelf) - 30,40,50,or60).Supports Eaton BR220B,BR2306 and BR240B circuit breakers compatible with hold-down kit. Z • Flexible networking supports Wi-Fi. Z - Ethernet.or cellular Circuit breakers(provided by Enphase) BRK-10A-2-24OV,BRK-ISA-2-24OV,BRK-20A-2P-24OV,BRK-15A-2P-24OV-S.and BRK-20A-2P-240V-B O • Optional AC receptacle available for PLC XA-SOLARSHIELD-ES - Replacement solar shield for IQ Combiner 4/4C bridge It L • Provides production metering and XA-ENV2-PCBA-4 - IQ Gateway replacement printed circuit board(PCB)for IQ Combiner 4/4C ~ - IQ Series Microinverters IQ System Controller 2 consumption monitoring XA-PLUG-120-3 - Accessory receptacle fo•power line carrier in IQ Combiner 4.,4C(required for EPLC-01) J The high-powered smart grid-ready IQ Series Provides microgrid interconnection device Simple X-I0-NA-HD-125A - Hold-down kit for Eaton circuit breaker with screws 0 Microinverters(I06.IQ7,and I08 Series) (MID)functionalit b automatically detecting Centered mounting brackets suUNITSpport to y y y g g pport single SPECIFICATIONSELECTRICAL dramatically simplify the installation process. grid failures and seamlessly transitioning the stud mounting E 0: home energy system from grid power to backup Supports bottom,back and side conduit Rating A 80 o Q power. entry System voltage and frequency - 120/240 VAC,60 Hz c~i ' J Up to four 2-pole branch circuits for % 240 VAC plug-in breaker a(not included) Busbar rating A 125 0 U N 80 A total PV or storage branch circuits Fault current rating kAIC 10 Reliable Maximum continuous current rating(input from PV/ A 64 • Durable NRTL-certified NEMA type 311 storage) �—' enclosure Maximum fuse/Circuit rating(output) A 90 IQ Battery IQ Load Controller Five-year limited warrarty e)A]-in-one AC coupled storage system that is Helps prioritize essential appliances Branch circuits(solar and storage) _ Up to four 2-pole Eaton BR.Siemens Q.or GE/ABB THQL Series distributed generation(DG)breakers • Two-years labor reimbur<_ement program only(not included) reliable,smart,simple,and safe.It provides during a grid outage to optimize coverage included for both the IQ Combiner backup capability,and installers can quickly energy consumption and prolong SKU's Maximum total branch circuit breaker rating(input) A 80 A of distributed generation/95 A with IQ Gateway breaker included design the right system size to meet the needs battery life. (yED A of both new and retrofit solar customers. UL Listed IQ Gateway breaker A 10 A or 15 A rating GE/Siemens/Eaton included `hk`VN FEhOCyiJ, • X2-10-AM1-240-4 and X2-10-AMl-240-4C comply with IEEE 1547:2018(UL 1741-30.3rdProduction metering CT A 200 A solid core pre-installed and wired to IQ Gatewayamm Ed.) Consumption monitoring CT(CT-200-SPLIT/CT- 200-CLAMP) A A pair of 200 A split core orclamp-type current transformersHOM ��9,� orsy,, OF NE`Ny 5-year limited warranty Refer to the https://enphase.com/installers/resources/warran page for cou-itry-specific warranty information. PAGE NAME: SPEC SHEET 9 2024 Enphase Energy.AN rights reserved.Enphase.the a and CC logos.IQ and certain Other marks listed at https://enphase.com/trademark-usaq suidelinas are tademarks of DWG NG. INSTALL NO: Enphase Energy.Inc.in the U.S.and other countries.Data subject to change. IOC-4-4C-DSH-00217-2.0-EN-2024-04-12 To learn more about Enphase offerings,visit onphase.com. IOC-4-4C-DSH-M217-2.0-EN-2024-04-12 PV-6.2 DESIGNER: OC BY: SYSTEM SIZE. DATE: 4A4 hw 1012212024 $ a a Z n w T � .i MECHANICAL DATA DESCRIPTION Z Dimensions(W•H=D) cm(in) 37.5•49.5*16.8(14.75.19.5.6.63).Height is 53.5(21.06)with mounting brackets 2 F- Weight kg(Ib) 7.5(16.5) Il Ambient temperature range 'C("F) IX -40 to 46(-40 to 115) U W Cooling - Natural convection Pius a heat shield Enclosuree"Aronmental rating - Z Outdoor.NRTL-certified.NEMA type 3R,polycarbonate construction 0 •20 A to 50 A breaker inputs:l4 to 4 AWG copper conductors � •60 A breaker branch input:4 to 1/0 AWG copper conductors W Wire sizes - Main lug combined output:10 to 2/0 AWG copper conductors •Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor suing Altitude m(ft) Up to 2.600(8.530) COMMUNICATION Integrated Wi-ci - 802.11b/g/n(dual band 2.4 GHz/5 GHz)for connecting the Enphase Cloud through the irternet Wi-Fi range;recommended) m(ft) 10(32.8) Oy/ Ethernet - Optional 802.3.Cat5E(or Cat 6)UTP Ethernet cable(not included)for connecting to the Enphase Cloud L.L through the irternet Y M 1 O rn Digital I/O - Digital input/output for gr d operator control E--W USB 2.0 _ For Mobile Connect.Communications Kit 01 for IQ Battery 3/3T/10/I0T.Communication Kit 02 for Q Z} IQ Battery5P a LLI Access point(AP)mode - Y P For connection between the IQ Gateway and a mobile device running the Enphase Installer App U(� Metering port:> - Up to two Consumption CTs.one IQ Battery CT,and one Production CT (n o 0 2 Power line communication kHz 90-110 Q ch U Web API - See https://developer-v4.enRbAse.com W Local API - See Guide for local API N CELLMODEM-MI-06-SP-05.CELLMODEM-Mi-06-AT-OS(4G-based LTE-MI cellular modem).Note 0 Z m Cellular/Mobile Connect - that an Enphase Mobile Connect cellular modem is required for all installations with Enphase 10 Batteriesand/ o or IQ System Controllers COMPLIANCEIn Z CA Rule 21(UL 1741-SA) 0 IEEE 1547:2018-UL 1741-SB.3rd Ed.(X2-I0-AMl-240-4 and X2-IQ-AMl-240-4C) IQ Combiner with IQ Gateway CAN/CSA C22.2 No.107.1,47 CFR.Part 15,Class B,ICES 003.NOM-208-SCFI-2016 (- Production metering:ANSI C12.20 accuracy class 0.5(PV production).UL 60601-1/CANCSA 22.2 No.51010-1.IEEE n 2030.5/CSIP Compliait COMPATIBILITY0 E In PV Microinverters 106,107.and I08 Series Microinverters Ix to System Controller EP200G101-M240US00 0 � d 0 U � 0 COMMS-KIT-01 IQ System Controller 2 EP2C0G101-M240US01 0 Z o N IQ Battery ENCHARGE-3-lP-NA,ENCHARGE-10-lP-NA,ENCHARGE-3T-IP-NA.ENCHARGE-10T-lP-NA IQ System Controller 3 SC200D111C240US01,SC20OG11IC24OUS01 COMMS-KI7-02' IQ Battery IQBATTERY-5P-lP-NA 'For information about IQ Combiner 4/4C compatibility with the 3r1-generation batteries,refer to the compatbility matrix. �FRED ARC 4�VN FEn,O'1�J, try � •9� 1961'I y OF N PAGE NAME: SPEC SHEET IOC-4-4C-DS H-0021J-2.0-EN-2024-04-12 DWG NO: INSTALL NO: PV-6.3 F ER: OC BY: M SIZE: DATE: KW 10/22/2024 a ACCOUNT #: 9624516002 W METER #: 98300586 i i Z i O co F- o_ � p U i W a Z TO UTILITY (E) 0 120/240V AC 120/240V > SINGLE PHASE SERVICE It ROOF BASEMENT unLm METER Y (1) RED *12 AWG PV CABLE, (1) RED #12 AWG THWN-2, EXTERIOR WALL J (1)BLACK #12 AWG PV CABLE, (1)BLACK#12 AWG THWN-2, -- — o— — 0 #6 AWG BARE CU GND (1) GRN#8 AWG THWN-2 GND , N o W IN 1" MIN. RMC BASEMENT Y u.) O rn IQ COMBINER BOX 4/4C FL W SYSTEM SIZE:4.14KW DC, 3.42KW AC (E) QO LOAD CENTER Q 0 Z COMBINER BOX #1 (d( 200A MAIN PANEL o ui (9)REC REC460AA PURE-RXMODULES SOLADECK 0786-41 \4` 200A MAIN BREAKER Y O (9) ENPHASE IQ8X-80-M-US MICROINVERTER GATEWAY = CT 20A -BACKFEED BREAKER 15A -- Z"'� STRING 1: (9) — _ — — c PANELS/STRING w+ w- w« w- w. w- w+ w- 20A __ L°A°le> NEUTRAL W — �'---. IRREVERSIBLE -- BUS N connrvuous CRIMP - _ _-- - ERB z GROUND o m BUS Z _ (1) RED#10 AWG THWN-2, O (1) BLK#10 AWG THWN-2, FACILITY (1)WHITE#10 AWG THWN-2, GROUND E- (9) REC REC460AA PURE-RX (9) ENPHASE IQ8X-80-M-US WEATHER INFO — (1)GRN #8 AWG THWN-2 GND MODULES MICROINVERTER IN 3/4"MIN. EMT Zip Code 11935 0 Pmax 460W Peak output power 384 VA Max Average N High 31°C/87.8°F Voltage at Max Power Maximum continuous 380 VA E Ix 54.90 V output power ° ° (V)Vmp: P Record High 34 C/93.2 F � M Q Current at Max Power Maximum continuous ELECTRICAL NOTES -' A Imp: 8.38 A output current 1.58A Record Low -15°C/S.0°F O o � � Open Circuit Voltage (VOC) 65.30 V Nominal frequency 60 Hz 1. ALL CONDUCTORS ARE COPPER UNLESS NOTED OTHERWISE. Short Circuit Current Maximum units per 20 (A) Isc 8.88 A A(L-L) branch circuit3 10 2. AC & DC GROUNDING CONDUCTORS PER NEC ARTICLE 690.47(c)(2) CONNECTED AS PER 250.64(c)(1) System Voltage 1000 V CEC Efficiency 96.5% 3. ALL EXTERIOR MOUNTED COMBINERS, ]UNCTION BOXES, TROUGHS, DISCONNECTS, ETC. SHALL BE MIN. NEMA 3R RATED, (aEDA/,C 4\)H FEN 4. CT'S TO BE LOCATED BETWEEN THE MAIN BREAKER AND THE LINE SIDE TAP. it -4 LABELS ON THE CT SHOULD BE FACING THE TAP. '9J� 18611 ,l OF N PAGE NAME: THREE LINE DIAGRAM DWG NO:: INSTALL NO: PV-7 DESIGNER: Oc BY: SYSTEM SIZE: DATE: 4.14 KW 10122l2024