Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
49813-Z
OF 30(/ryo`o Town of Southold * * P.O. Box 1179 �0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45998 Date: 02/25/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1360 Sterling Rd Cutchogue, NY 11935 Sec/Block/Lot: 104.-4-14 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 04/14/2023 Pursuant to which Building Permit No. 49813 and dated: 10/02/2023 Was issued, and confonns to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar with enclosed battery storage to existing single-family dwelling as applied for. The certificate is issued to: Lee Schultheis Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 49813 2/24/2025 PLUMBERS CERTIFICATION: Auth ed gnature �o�soFeot�co TOWN OF SOUTHOLD Gy BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE AMENDMENT oy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49813 Date: 10/2/2023 Permission is hereby granted to: Schultheis, Lee 136.0 Sterling Rd Cutchogue, NY 11935 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. O`1�262 4AMEND{R it #o include battery storage as applied for. At premises located at: 1360 Sterling Rd, Cutchogue SCTM # 473889 Sec/Block/Lot# 104.-4-14 Pursuant to application dated 9/14/2023 and approved by the Building Inspector. To expire on 4/2/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector �guFFol, co- TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49813 Date: 101212023 Permission is hereby granted to: Schultheis, Lee 1360 Sterling Rd Cutchogue, NY 11936 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 1360 Sterling Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 104.4-14 Pursuant to application dated 9/14/2023 and approved by the Building Inspector. To expire on 4/2/2025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO RESIDENTIAL $50.00 Total: $200.00 Building Inspector pF SO(/r�,ol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q -�► • ao Jamesh _southoldtownny.gov Southold,NY 11971-0959 COUNTY,Nc� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lee Schultheis Address: 1360'Sterling Road city:Cutchouge st: New'York zip: 11935 Building Permit* 49813 Section: 104 Block: 4 Lot: 14 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Element Energy LLC. Electrician: Jamie Minnick License No: 52698-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12.15kw roof mounted solar energy system with 30 panels[DUO BLK ML-G10+ 4051 30 micro inverters[IQ8PLUS-72-2-US] 2 Sonnencore+ ESS batery back ups 2 100 amp sub panels w Notes: 4 40amp breakers,1 enphase combiner panel, 1 60amp fused disconnect, 1 load panel 100a 1 200amp Path-Through ac connections Module SOLAR ENERGY PV SYSTEM Inspector Signature: jAs 1,0,/ Date: February 24, 2025 1360 sterling rd OE SOUIyO� # . TOWN OF SOUTHOLD BUILDING DEPT. o m��' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND. [ ]ANSULATIOWCAULKING [ ] FRAMING/STRAPPING [ FINAL [*/ 8 W. s e, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 117 Llool DATE INSPECTOR IV41 soolyo� /�� g S 'r' TOWN'OF SOUTHOLD' BALD G DEPT. co 631-765-1802 INSPECTION . [ ] FOUNDATION .1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT-CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) - [)('J ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: (a r DATE a 2� INSPECTOR J. A.A� - - -- �_ - ---- -- - -- oF SO(/TyO� �{�g z 3 360 PV TOWN-OF SOUTHOLD BUILDG DEPT. : 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND . [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY. [ ] 'FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ]- ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Sn(ct r DATE °2 2 INSPECTOR p �] Zoho Sign Document ID:2A768FFA-2MLDY-91010JITZXYN5V4DIOTONEIZIYTS7U_QIGXIW Town of Southold D , Beer 1 , 2024 Building Department Town Hall Annex 54375 Main Road peps �Od,� P.O. Box 1179 �' ®° o§SOU Southold, New York 11971-0959 Subject: Battery Energy Storage System and Roof-Mounted PV System at Schultheis Residence, Located at 1360 Sterling Rd, Cutchogue, NY 11935 To Town of Southold: I hereby affirm and certify that, following comprehensive professional evaluations,the plans for the installation of both the Solar PV System and the Battery Energy Storage System (BESS) comply with the 2020 Residential Code of New York State, the 2020 Building Code of New York State, the 2020 Fire Code of New York State, the 2017 National Electric Code, ASCE 7-16, and other relevant industry standards and regulations.These certifications are provided in strict adherence to the governing regulations and standards applicable to such installations. For the Solar PV System, it is my professional opinion that the subject plans comply with the aforementioned codes and standards. The structural framing of the existing roof has been evaluated to support the additional loads from solar panels, with deflection and stresses within allowable limits for wind pressures and snow loads specified in the codes. The mounting locations and methods indicated in the plans are deemed adequate, and the existing building and roof framing are structurally sufficient to support the solar panels. Regarding the Battery Energy Storage System(BESS), the proposed plans have undergone thorough scrutiny and are confirmed to align with requisite codes and standards. Utilizing Lithium Iron Phosphate technology, the BESS adheres to UL9540A standards to prevent thermal runaway. The enclosure design meets fire-resistant requirements outlined in the NYS Building Code. In my professional opinion, derived from site inspections and detailed analyses, both the proposed Solar PV System and the BESS, including the enclosure system, demonstrate structural adequacy to withstand associated reactions. Please feel free to contact me if you have any questions or require further clarification. Sincerely, �o- NE Gennaro Anthony Giustra. P.E. Great Eastern Services, Inc. * �_ PO Box 240 24 Harvey Rd Riverhead, NY 11901 103445 Mobile:631.235.0189 AR�FEsS1 Email: jerrygiustra@gmail.com LIQS I S 0 Zoho Sign Document ID:2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQN II U_1GXIW Town of Southold December 18th, 2024 Building Department Oe�vpp t" o�d Town Hall Annex g 54375 Main Road P.O. Box 1179 �o Southold, New York 11971-0959 Subject: Battery Energy Storage System and Roof-Mounted PV System at Schultheis Residence, Located at 1360 Sterling Rd, Cutchogue, NY 11935 To Town of Southold: I hereby affirm and certify that, following comprehensive professional evaluations, the plans for the installation of both the Solar PV System and the Battery Energy Storage System(BESS) comply with the 2020 Residential Code of New York State, the 2020 Building Code of New York State, the 2020 Fire Code of New York State, the 2017 National Electric Code, ASCE 7-16, and other relevant industry standards and regulations. These certifications are provided in strict adherence to the governing regulations and standards applicable to such installations. For the Solar PV System, it is my professional opinion that the subject plans comply with the aforementioned codes and standards. The structural framing of.the existing roof has been evaluated to support the additional loads from solar panels, with deflection and stresses within allowable limits for wind pressures and snow loads specified in the codes.The mounting locations and methods indicated in the plans are deemed adequate, and the existing building and roof framing are structurally sufficient to support the solar panels. r" Regarding the Battery Energy Storage System(BESS),the proposed plans have undergone thorough scrutiny and are confirmed to align with requisite codes and standards. Utilizing Lithium Iron Phosphate technology,the BESS adheres to UL9540A standards to prevent thermal runaway.The enclosure design meets fire-resistant requirements outlined in the NYSI Building Code. In my professional opinion, derived from site inspections and detailed analyses, both the proposed Solar PV System and the BESS, including the enclosure system, demonstrate structural adequacy to withstand associated reactions. .t Please feel free to contact me if you have any questions or require further clarification. Sincerely, Gennaro Anthony Giustra. P.E. ai rG Great,Eastern Services, Inc. * w= PO Box 240 m 24 Harvey Rdip Riverhead, NY 11901 Fo 10344b Mobile: 631.235.0189 AR° ss1oNP� Email: jerrygiustra@gmail.com u r 4 I l w� Id, DEC 202024 �� �, �r--- — a .. i l� P � 4gB�3 bwlJ%� Tn�n I . 13 c� o s�-��- I►�� � w W,LD INSPECTION REPORT I DATE COMMENTS •o FF FOUNDATION (1ST) ----------------------------------- i C FOUNDATION (2ND) z o H ROUGH FRAMING& y PLUMBING r r� INSULATION PER N.Y. STATE ENERGY CODE C1 FINAL rn ADDITIONAL1 COMMENTS la z'7 (�- 6-aP-laos , H x H x d b H =o�gpFFot��oGy� TOWN OF SOUTHOLD-BUILDING DEPARTMENT y x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowym�.Rov_ Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only R cc PERMIT NO. �jJ Building Inspector: Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Depa"Me"t Owner's Authorization form(Page 2)shall be completed. Town of Southold Date: 1/ 1 OWNER(S)OF PROPERTY: Name: �� �- SCTM#1000- Project Address: l! U � -C_h.0_. _.LAQ��..__ . Phone#: (p _-�� Ct Email: Mailing Address: CONTACT PERSON: Name: c�-, _�__��____ Mailing Address __ Phone#: (� _ _ Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address:Phone#: � 1 Email: DESCRIPTION OF PROPOSED CONSTRUCTION [:]New Structure ❑Additio [--]Alteration E]R�e�pair ❑Demolition Estimated Cost of Project: Other �O I4-k- i�V S �TC�'�' 1 $ f O `7 DLDO' Will the lot be re-graded? ❑Yes-No Will excess fill be removed from premises? E Yes o mo �5o 1 C'L Y- V W.-S-4FMa,is' IC Lk;) 30 mod u yes peon �' etc K l I��L� C7 /� + Cf ('0 1 PROPERTY INFORMATION Existing use of property: Intended use of property: P Zone or use district in which prs is situated: Are there any covenants and restrictions with respect to this property? ❑Yes o IF YES, PROVIDE A COPY. eck Box'After Reading: The owner/contractor/design professional is"responsible fo`r all drainage,end storm water issues as-provlded by_ Chapter 23b of the Town Code;APPLicAtioN is HEREBY MADE to the Bwlding beparement forthe issuance of a Building Permit pursuarrt"to the Building Zone Ordinance of the Tawg of SoutF old;Suffolk,County,Nevi-York ai46therapplka6le laws,Ord eances or Regulations,for tEie construction of6uildings, addit!o As.aiterations orforremova[or demob#ion as herein described THe appluant agrees to comply with all applicable laws,ordinances,building Bode, Housing code and regulations acid to admit authorizedinspectors on premises and in-F uilding(s)`for necessary inspections..False.statements.made herein amf- punisfia6le as a Class A misdemeanor pursuant to Section210 45 of the Newyork State Penal tour t_ Application Submitted By(print name): inQ-,,xb /// t r'P- u'thorized Agent Downer Signature of Applicant: 0O�YZk.� 19-f 1P � Date: STATE OF NEW YORK) SS: COUNTY 0F&qjf::01 ) Lo r6Lj- 1Qt -bi being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the C(�Yl (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,"and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of J.G . 20 ZO N ary Public 40 PROPERTY OWNER AUTHORIZATION �A ArOtati 4b c�SiJA (Where the applicant is not the owner) ''ss�,od�%ea rgotat�MFO n p�sNo�kcOf 04eh'y°rXr 1 I, L�_� Chu- We-1-Is residing at 13(P D Sher-[l r7 U►�(/�- ,20e. l l °t 35 6 L�,- ch q u�, N y do hereby authorize i le-MC114-15j'1e VA- C.t-C_,jLo lx-i,,,.-e. to apply on my b a to own f Sou 'Iding Department for approval as des ribed herein. 131a3 Owner's Signature Date f /,, 1, Notary Puub it�cs State of w York 1��' �' r f J No.01 R06314813 Print Owner's Name CommiOualiified in Suffolk County Expires November 17,20 T3 2 BUILDING DEPARTMENT- Electrical Inspector a Gym TOWN OF SOUTHOLD o =` Town Hall Annex - 54375 Main Road - PO Box 1179 o - Southold, New York 11971-0959 d O� Telephone (631) 765-1802 - FAX (631) 765-9502 ro err(ftoutholdtownny.gov -seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: le-me-ri+ inner (,PLC Electrician's Name: p�ryl!' 1'Ylr'n n I" K License No.: 5 a (n g q_M C Elec. email: @� S S ,COS Elec. Phone No: (03 --J7,9 ;7 q3 ©I request an email copy of Certificate of Compliance Elec. Address.:?q rl 0 60U.l1k AVt.� M�--�-�'1- AC JOB SITE INFORMATION (All Information Required) Name: lac S &)L.0 [ he-I'.S Address: 13(,Q O Cross Street: Phone No.: (p,j �7 q-'7 .10! Bldg.Permit#: email: {���-,�-�� P a S g•� Tax Map District: 1000 Section:I o L4,oe Block: 0 otD Lot:O I y, 0 ox-1 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): a Lo Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESMNO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame Pole Work done on Service? Y 7N Additional Information: -F(us hroo_-F_mo tA-rn-fed,- �o(ci,^ tO V 3 YSk re) 30 rno dL&le.s js k u� D ko 3� r� ve✓YtyS _en r''t�seJ - �cx P 1 LL dJo�{�c�'t 1 PAYMENT DUE WITH APPLICATION K121 00 d BUILDING DEPARTMENT- Electrical Inspector gip\► aGy� TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 C' Southold, New York 11971-0959 �4,o �a� Telephone (631) 765-1802 FAX (631) 765-9502 rogerr(a-Dsoutholdtownny gov — seandc@-southoldtowriny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: i'' Crl.-+ rl�y Lrl-C Electrician's Name: a n'l1` fir''n n)" License No.: 5 g -M C. Elec. email: S C C Elec. Phone No: %Q 13 ®1 request an email copy of Certificate of Compliance Elec. Address.:'lLl 'l C 6i)IkA . aVt/ MA,{- 114 l y- JOB SITE INFORMATION (All Information Required) Name: �, -S C_h u 1 he-,k-3 Address: 13(,00 &k4)' e )o CLC- d V Ll 9 3 Cross Street: Phone No.: &,) / -77 e-7 ol q BIdg.Permit#: email: Pe-,-no)'1-;s a J S-C 0 Tax Map District: 1000 Section:I o „o Block: b 9. vo Lot:;©I y,O oc BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: YESMNO Rough In El Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size01 Ph03 Ph Size: A # Meters Old Meter# ❑New Service Fire ReconnectO Flood ReconnectOService Reconnect OUnderground'OOverhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: -F(LA-s V1 roo F ry)+o+,A-n*eA— �S01`"- 10 V -SyS-k r,1 :2. 1 S kw 30 mbd"Ies - CQ ce-d - Pe-eLk Z)uo 6/< (z,c1jv p_�, ) PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc .e Combo Cooktop Minisplit Blower .AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments i O�gt►Ff0(,��oD BUILDING DEPARTMENT- Electrical Inspector �� yam► TOWN OF SOUTHOLD H Town Hall Annex - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 Telephone (631) 765-1802 -FAX (631) 765-9502 �l ' rogerr(ebsoutholdtowngy-cloy—seand4southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 02, Company Name: IF B M CA4 E n e c Si I-L_Cj Electrician's Name:ao rxNt., 1-f) f y)n g eK License No.: (no Q _ 1�+E EIec. email: Pe r-rn s+_5 �, Cap 1,S, c()'k Elec. Phone No: -)oto0 [9I request an email copy of Certificate of Compliance Elec. Address.: -7 4-7 o so a/)tL ave, "4_X&CV, OJ JOB SITE INFORMATION (All Information Required) Name: Li n e, � M1-4+k;E Address: 1 ) jRA Cross Street: <` �, Phone No.: � 1 .15$$ . `7 ®L f ' Bldg.Permit#: i email: Ptr-MALS Tax Map District: 1000 Section: Ob Block: U J.d u Lot:b I Lj, oco BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 40 'S a I^-r- .h'1 • `y. 13,° q l Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES® NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 71 2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ggiFOlq '�, TOWN OF SOUTHOLD —BUILDING DEPARTMENT � fA 2. `Down Hall Annex 54375 Main Road P. 0. Box 1179 Southold, NY 11971-0959 :'s,�o• ��' Telephone (631) 765-1802 Fax (631) 765-9502 https:,'!'w�&riv.southoldtownnv.gov �Cy Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only L " J t_. PERMIT N0. Building Inspector: DEC _ � 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an 1577 1,�.NT DES";', Owners Authorization form(Page 2)shail be completed. Date: ( l '30/ a'6 OWNER(S)OF PROPERTY: Name: S� .j -mei S SCTM#1000- l O y, oo -0 4, oo - o) ki Project Address: 1'3 (,0 &I1,j 1• CL, +1 110.1 Ut-1) V. 110135 Phone#: 3 (- 3 8 2 . ?0 L I Email: P-e C 14-z� a,s '.co Mailing Address: �� �.�.G�� , "1 � ti ,/' Q3S CONTACT'PERSON- Name: � I Name: L-p rrdl.l A eMailing Address: -7410 V UUAd fty-J Mb,- 4-j-ck Phone#: ('.3 9 d 3 o 2 -7 O eI / Email: pe'r1Y1)+5 e, 02 s S . co k-" I bESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: 1 4 �54 � �� �1 ���� I�✓1� 01 q� Phone#: �3 I . 3 0O 2 ,—, D 4 ) Email: P1?iD` 4.s� c z c$b coo, DESCRIPTION O POP OSEDSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair [I Demolition Estimated Cost of Project: ther i Q'q- .1 () kw h S-kkGkC/- $ 4,5 0 ri 0, r Will the lot be re-graded? ❑YesXNo Will exces f II be remove from premises? Yes o i PROPERTY INFORMATION Existing use of property: Intended use of property:. Zone or use district in which pre ises is situated:: Are there any covenants and restrictions with respect to this property? OYes )WS o IF YES,PROVIDE A COPY. eck Box After Reading: The owner/conb cteydesign professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department forthe issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,NewYork and other applicable Laws;Ordinances or Regulations;for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to compiy with all applicable laws,ordinances,building code, housing node and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a class A misdemeanor pursuant to Section 210AS of the New York State Penal Law- Application Submitted B (print name • n Y�P )• �rr�-I•�e��i r'u� )AV-1thorized Agent []Owner d �� Date: l 13l i , Signature of Applicant: STATE,OF NEW YORK) SS: COUNTY OF being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, i (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and Js duly authorized to perform or have performed the said work and to make'and file this application;that all statements contained in this applicationare true to the best of his/her knowledge and}belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this / day of. s C is 20 Z? N""-a.ry Public PR_O_PERTY0._WNER AUTHORIZATION n,� QG:Navb��'sJRO (Where the applicant is not the owner) 96 Np 1• -C�..-'S�U.I �C is. _- residing at 13 iP D sT !'� LU q v�j, 1.!Lk do hereby authorize( _2mtrt. v' l.4 C,.:COI'3'd= e lb-apply on my b a to own. Sou ilding Department for approval as described herein.. Owner's Signature _ Date LOUIS J ROMEO bep C h 1 Nay Rub!!c State of NdW}lark - L No OiR0831483 Print Owner's Name Cgmmrssio Qualified in Suffolk County j n:Exprr�'�Novemter 2 CERTIFICATE OF LIABILITY INSU DATE RANCE WIT 3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: M the certificate holder is an ADDITIONAL INSURED,the policyPGS)must have ADDITIONAL INSURED provisions,or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does notconfer rights to the certificate holder in lieu of such endarsement(s). PRODUCER CONTACT ROBERT S.FEDE INSURANCE AGENCY NAME: PHONE I Pf 23 GREEN STREET,SUITE 102 fix.No Eat: Na HUNTINGTON,NY 11743 no° ss: ROBERTS.FEDE INSURANCE INSU s AFFORo1No coVERAOE Nalc INSURER A;ATLANTIC CASUALTY INS.CO. 5242i0 INSURED Element Energy LLC INSURER DBA ELEMENT'ENERGY SYSTEMS e7sLo` 7470 SOUND AVENUE INSURER° MATTITUCK,NY 11952 INSURERE. VISURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLANS, INSR LTR TYPE OF INSURANCE 001. POLICY NUMBER POLICY OIDD LIC EFF POLICY EV LIMITS 7114rM4 A COMMERCIAL GENERAL LIABILITY X X L1460036873 EACH OCCURRENCE S 3,aQa,aoa CLAIMS-MADE ©OCCUR PREMISES Eaoadurmioe S 100,000 X Contractual tia MED EXP 3 5,000 7119/2022 7/192024 PERSONAL&ADVINJURY 3 3000000GENL GGREGATE LIMIT APPLIES PER aEC GEWRAL AGGREGATE S POLICY T LOG PRODUCTS-COMPlQPAGG S OTHER: s A 17ALEUABIITY C Otrer sINGLELIMIT S ANY AU70 BODILY INJURY(Per person) $ VNED SCHEDULED AUTQS ONLY AUTOS BODILY INJURY(Per accident) S HIRED NDN•OWNEDPE �IDAIpADE AUTOS ONLY AUTOS ONLY $ $ UMBRELLA LIAB OCCUR EACtIOCCURRENCE S EXCESS LIAB CLAWS-MADE AGGREGATE S DED I I RETENITION S vroRlcERs c OeIPENSAMAI $ AND EMPL0 rffiW LIABILITY124494445 PER OTH- ANY PROPRIE MRIPARTNMEXECUTnrE Y J N 7/132023 7/13/2024 TA ER B OFpCERrn RaBER EXCLUDED? NIA E.L EACH ACCIDENT S 1 Oaa Oaa (Mandatory in NH) If yes,descobs under EL DISEASE-EA EMPLOYE S DESCRIPTION OF OPERATIONS below EL DISFJISE-POt@CY L1MR ; NY State DBL DSL567527 1/01/2023 12/3112024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS r VEHICLES(ACORO 101,Adif lenal Remarks Schedule,maybe alteehed if more space is reWrad), CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted,operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE IPZI S. Fede. 01988-2015 ACORD CORPORATION. All rights reserved. arson tic nn4em>T rk-Ae'MDr% ..».._j I_____ —4 Arson f NYSMF New York State Insurance Fund PO Box 6W99,Albany,NY 12206 nysifcom CERTIFICATE OF WORKERS'COMPENSATION INSURANCE (RENEWED) a o n n n n n n 823336604 = ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 0 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07/13/2023 TO 07/1312024 7/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444.5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:IA W M.NYSIF.COM/CERTICERTVAL.ASP.THE'NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY_ NEW YORK STAT SU NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING Meyer, Nancy From: Meyer, Nancy Sent: Tuesday,January 2, 2024 9:39 AM To: permits@e2sys.com' Subject: 1360 Sterling Road Good morning, Happy New Year. I received the application for the battery storage proposed at the Schultheis residence in Cutchogue. This will be an amendment to the existing solar permit. However,in order to issue the amendment for permit,we will need: -A drawing(plan and elevation)showing the proposed location of the proposed units, including dimensions,fire protection measures,clearances,etc. ` -Manufacturer specs of the units you wish to install Once we have that information,we can review the units for compliance to code. If you have any questions,feel free to reach out to the building department. Thank you, , .9lyancy meyel- Building Inspector Town of Southold Building Department Annex Building 54375 Main Road Southold,NY 11971 (631) 765-1802 1 Meyer, Nancy From: Meyer, Nancy Sent: Tuesday, February 27, 2024 9:29 AM To: 'permits@e2sys.com'; 'kevin.byrne@e2sys.com'; 'lorraine.dipenta@e2sys.com' Subject: 1360 Sterling Rd Good morning, I am reviewing the amendment dropped off for the Schultheis residence,where you are looking to include battery storage. The drawings which were provided are lacking information: Are the units proposed inside the garage? Immediately outside? Is the garage attached? What kind of fire separation is being proposed between the garage and the dwelling? What are the clearances proposed? Are they manufacturer specs? We can review for compliance once the additional information is received. If you have any questions,feel free to reach out to the building department. Thank you, .Nancy.Meyer Building Inspector Town of Southold Building Department Annex Building 54375 Main Road Southold,NY 11971 (631) 765-1802 i rAF APFAOVED AS NOTED DATE: ® ' 3 B.P.# . _ OCCUPANCY OR FEE -OD BY: USE IS UNLAWFUL NOTIFY BUILDING DEPARTMENTAT WITHOUT CERTIFICATE 631-765-1802 8AM TO 4PM FOR THE OWING INSPECTIO 1. FOUNDATION-TWON REQUIRED OF OCCUPANCY FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL•CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OFTHE CODES OF NEW COMPLY WITH-'ALL CODES`OF YORK STATE. NOT RESPONSIBLE FOR NEW YORK STATE & TOWN CODE$ DESIGN ORCONSTRUCTONERRORS AS'REQUIRED AND"'CONDITIONS OF �'SOAOI b'TOWN ZBA T, - ITHOLVOWN PLANN1480ARD a: -SOUTyOLDTOWN TRUSTEES N -DEC RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. -J Zoho Sign Document ID:2A768FFA-FURLI_UUVEM7YHSVDHFU6ZUVNPEBUNJRB9K1(UILWU51 Town of Southold August 18th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Schultheis Residence, 1360 Sterling Rd. Cutchogue, NY 11935 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood; it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.6 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. OF SIV Great Eastern Services, Inc. C� c�Gs��� PO Box 240 * `� 24 Harvey Rd Riverhead, NY 11901 2 Mobile: 631.235.0189 N�4 103443 Email: jerrygiustra@gmail.com AR�FESs�oNP� Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 SCOPE OF WORK DESIGN dr DRAFTING BY: ELEMENT ENERGY LLC TO INSTALL A 12.15 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT SCHULTHEIS RESIDENCE, ' REVIEW BY J.M.NABCEP CERTIFIE Shelt erlsland 05 I I 1 2-129 LOCATED AT 13G0 STERLING RD, CUTCHOGUE, NY 11935. - � Fleighls� THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH z5 d THE EXISTING ELECTRICAL SERVICE EQUIPMENT. A Southold sheberisland REVISIONS i DESCRIPTION DATE REV ai P nic e ORIGINAL 05-15-2023 SYSTEM RATING 12.15 kW DC 5TC 'tl Cutdt i., North Haven enr voixr - t SuHotk oyad: - Sa9�9 Harbor_.. EQUIPMENT SUMMARY " ° 30 QCELL Q.PEAK DUO BLK ML-G 1 O+405 WATT PV MODULES t� LaureI ! ! - , T. II 30 ENPHASE IQ8PLUS-72-2-U5 MICRO INVERTERS LL _ CONTRACTOR I IRONRIDGE XR 100 MOUNTING SYSTEM 75 ELEMENT ENERGY, LLC. Jame SHEET INDEX Pv-I COVER 50� � .ra 7470 SOUND AVE MATTITUCK, NY 1 1952 PV-2 SITE PLAN PROJECT LOCATION LICENSE # G74G I-HI PV-3 ROOF PV LAYOUT LICENSE # 52G89-ME PV-4 STRUCTURAL/DETAILS SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM PV-G LABELS ��of NEIV GOVERNING CODES ��P��`� A * �2 2017 NATIONAL ELECTRICAL CODE. •,: = 2020 RESIDENTIAL CODE OF NEW YORK STATE. , b !' 2 2020 FIRE CODE OF NEW YORK STATE. , ASCE 7-1 G AND NFPA-70. �O �03443 UNDERWRITERS LABORATORIES(UL)STANDARDS 'ARo3S1 05HA 29 CFR 1910.2G9 GENERAL NOTES PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT Ow U Q m THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE m HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK z O� p IL/ AGREE THE SAME. AERIAL VIEW 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, LIU INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP z g Z CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, O AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES N W LLJ 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO ALL RULES AND REGULATIONS OF THE RESPONSIBLE JURISDICTION. COMMENCING WITH WORK. w _ Q . U 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I I EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR (D CMAINTAINING SAFETY ON THE JOB SITE DURING THE WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS U (Y) THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE w ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION.THIS SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME FABRICATED AND INSTALLED AS PER LATEST 5. ALL STRUCTURAL STEEL SHALL BE ATE AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT ST A.I.S.0 SPECIFICATIONS. CONSTRUCTION. COVE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C.NYS CODES $ REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND COMMENCING WITH WORK. DRAWING SCALE CERTIFICATION OF THESE PLANS. CONSENT THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THI5 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. N .I. . PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY IS TO BE EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV— RESULT OF HIS WORK. TAX MAP: 1000-104.00-04.00-014.000 Zohb Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 LEGEND TAX MAP: 1000-104.00-04.00-0 14.000 DESIGN fi DRAFTING BY: EXISTING unuTY METER MAIN SERVICE PANEL N ELEMENT ENERGY LLC 0° REVIEW BY J.M.NABCEP CERTIFIE NEW PV SUB-PANELS 051I12-129 A/C DISCONNECT I COMBINER INVERTERS '^' GND ELECTRODE V V 270 a REVISIONS ®PV MODULE 240° ®r7 �9pos DE5CRIFr10N DATE REV ORIGINAL 08-18-2023 —RACKING RAIL 210° 120° 0 ATTACHMENT POINT 15 0 ---RAFTERS 1ST° O -4-ROOF PITCH ANGLE s 59SUNRUN METER NVENT OPLUMBING VENT ®SKY LIGHT EXISTING UTILITY METER I5TING MAIN ELECTRICAL SERVICE PANEL ®CHIMNEY NEW PV AC D15COMMECT CONTRACTOR COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD CONDITION POTENTIAL SHADING IssuEs ® MATT TO C O NY I 5UNDA VE TRIM/RE 1552 � l10VE AS NECESSARY ® LICENSE # 52G89-ME of: NEIV y A G0�� P lu A 2 2 3'-4 I I 4 G 5 8 c� 10344S AR��ss�oNP�' @RIDGE////// @�RI�DiE j PROJECT NAME j < In U Q In W W W IV m u? - o j �N w z > 17'- 10" j>% jg 20- I IL/ D LLJ Iu (L U m (n — U WE j SHEET NAME SITE PLAN 39"x 36"GROUND ACCE55 TYP. NOTE 1 .)THE ROOF SETBACPPATHWAY SHALL NOT BE REQUIRED ON ROOF-SLOPES WHERE THE DRAWING SCALE OPPOSING OR ADJACENT ROOF SLOPE IS ANACCE Q Q = I SS ROOF IN ACCORDANCE WITH R324.G.I 11 1-011 EXCEPTION OF 2020 NYS RESIDENTIAL CODE. /V CONSTRUCTION NOTES 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NuMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. �` ,_^ C 2.)ALL OUTDOOR EQUIPMENT SHALL 5E RAINTIGHT WITH MINIMUM NEMA 3R RATING. v 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 CONSTRUCTION SUMMARY DESIGN 4 DRAFTING BY: (30)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES ELEMENT ENERGY LLC (� REVIEW BY J.M.NABCEP CERTIFIE (DIMENSIONS: 74"X 4 1.1"X I .3") �V os I I I z-I z9 (30) ENPHASE IQ5PLUS-72-2-US MICRO INVERTERS o0 (38)ATTACHMENT POINTS @ G4"O.C. MAX. (208) LF IRONRIDGE XR100 MOUNTING SYSTEM. I REVISIONS ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) W DESCRIPTION DATE REV CONSTRUCTION NOTES - 270 Q®rc90. ORIGINAL 08-18-2023 E 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 240-W ITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2��, 1200 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 180o1500 MINIMUM NEMA 3P.RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE S' FIELD VERIFICATION. EXISTING UTILITY METE ISTING MAIN ELECTRICAL SERVICE PANEL CONTRACTOR NEW PV AC DISCONNECT ELEMENT ENERGY, LLC. 7470 SOUND AVE IMATTITUCK, NY 1 195 ® ® C-2 LICENSE # G74G 1-HI LICENSE # 52G89-ME .` -pE NEW pgo Gp,P� �O r 103445 ARO�ss►oN�� PROJECT NAME j////////////// M 18°RRE SETBACK @RIDGE j///� j / 0 U Q m 31- III Lu z %1 %�/ 4 Iy R/ _, z ° w Lu w I— '/ O �m � _ jD j j;%/N V PANELTI?. LEGEND � 17— _ �E%ISTING UTILITY METER m U MAIN SERVICE PANEL NEW PV DISCONNECT CT� j L2'-9tI TRING/CONNECTION j#I 2 INVERTERS COMBINER SHEET NAME e GND ELECTRODE AR ARRAY#2 PV MODULE PV LAYOUT 20 MODULES 10 MODULES RACKING RAIL 0 o VpNb ICRO-INVERTERTYP. 22 PITCH 3�'�36'�GROUND ACCESS Tl'P. o ATTACHMENT POINT I G5'AZIMUTH I G ---RAPIERS f ROq"PITCH ANGLE DRAWING SCALE TSUNRUN METER I/QCVJ11 = 11-011 ®�T 'NOTE OPWMBING VENT 1.)THE ROOF SETBACK/PATHWAY SHALL NOT BE ®SKY LIGHT SHEET NUMBER REQUIRED ON ROOF-SLOPES WHERE THE ®CHIMNEY OPPOSING OR ADJACENT ROOF SLOPE 15 AN COMPOSITE E SHINGLES TION PV—J ACCESS ROOF IN ACCORDANCE WITH R324.G.I GOOD SITECON SIN EXCEPTION OF 2020 NYS RESIDENTIAL CODE. TAX MAP: 1 000-1 04.00-04.00-0 1 4.000 POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSAR Z6ho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 LOAD CALCULATION ARRAY#I ARRAY#2 ITEM DESCRIPTION ARRAYS #I-2 DESIGN 4 DRAFTING BY: RB Ricicie Bearn/Board 2"X 1 O" D. FIR ELEMENT ENERGY LLC R Rafter 2"X 8"D. FIR I G"O.C. REVIEW BY J.M.NABCEP CERTIFIE D L WEI HT(Lbs) 48.4 48.4 (D) DeckinrJ/8" PLYWOOD 05 1 1 1 2-1 20 #OF MODULE5 20 10 (K) Knee Walls 2"X G" D. FIR I G"O.C. REVISIONS J) Ceilln Joist 2"X 8" D. FIR I G"O.C. DESCRIPTION DATE REV TOTAL MODULE WEIGHT(Lbs) 968.0 484.0 (P) Pitch 22° TOTAL LENGTH OF RAIL(Ft) 138.7 69.3 (H) Horizontal Span of(R) 183" MAX. ORIGINAL 08-18-2023 RAIL WEIGHT PER FOOT(Lbs) 0.68 0.68 TOTAL RAIL WEIGHT(Lbs) 94.3 47.1 #OF 5TRANDOFFS 22 1 6 WEIGHT PER 5TRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 44 32 TOTAL ARRAY WEIGHT(Lbs) 1106.3 563.I POINT LOAD(Lbs) 50.3 35.2 CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 428.2 214.1 ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lbs/Sq Ft) 2,6 2.6 7470 SOUND AVE _ ( MATTITUCK, NY 1 1952 WIND DESIGN sUBjECTTO DAMAGE FROM LICENSE # G74G I-HI GROUND SEISMIC WINTER ICEBARRIER AIR MEAN SNOW d speciT11VIIdborne DESIGN Frost �ooD LICENSE# 52G89-MESpeed Topographic DESIGN UNDERLAYIAENT FREEZING ANNUALi��LOAD° (mph) elfectskwinebris cATEGORYf Weatheringa line Termitec TEMpe REQUIREDh HAZARDS$ IND& TEMPI (KVrM aOnem depthh 20 140 NO NO NO B SEVERE 3 FT ODHEA T 15°F YES ZONE X 599 51°F (�OF NEl7rYO IA ,�P OAG MANUALJ DESIGN CRITER ^ �� vfntet Summer Attitude Indoor Design Heating (H) ElevaGan Latitude heating cooling correction factor design temperature temperature cooling temperature difference Z 2 (J) ip 108 FT 41°N 15°F 86°F 1.00 70°F 75°F 55°F �O 70344 5 Mlind Cooling duty velocity Coincident Daily Wmter Summer AROFESSIONP�' temperature difference hea ng c ling wet bulb range humidity humidity tioo 11°F PROJECT NAME 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%RH I I � � ROOF FRAMING DETAIL I (Z W For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. O U Q m w ( 0� a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength 0 required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined w _ from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. 1,_ b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction � W z z shall fill in the frost line depth column with the minimum depth of footing below finish grade. d) � J C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined O (n on a site-specific basis in accordance with Section R301.2.1.4. N W W LLJ e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York MODULE MOUNTING CLAMP = State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also C) I — (S) lu see Figure R301.2(1).] SOLAR MODULE J in O = f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. O (� STAINLESS STEEL 3/b° IL = LQ g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New BOLT AND NUT O � m F— York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the 0 Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: I.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and RIDGE ALUMINUM RAIL iii.Related supporting data along with any revisions thereto. ALUMINUM°L°BRACKET SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1.R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM FLASHING effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." STRUCTURAL i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." ). The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method ASPHALT SHINGLE ROOF (Base 32°F)." 5/1 G°x 0 5TAINLES5 STEEL LAG BOLT WITH k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 1/2"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"In this part of the table. PENETRATION SEALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) AS NOTED m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet SHEET NUMBER (') See Figure R301.2(4)B. FV-4 TAX MAP: 1 000-104.00-04.00-014.000 MOUNTING DETAIL 1 Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 DESIGN t DRAFTING BY: SOLAR ARRAY ON MAIN HOUSE 1 2.1 5 kW ELEMENT ENERGY LLC (30)QCELL Q.PEAK DUO BILK ML-G 10+405 WATT PV MODULES REVIEW BY J.M.NABCEP CERTIFIE (3)STRINGS OF(10)MICRO-INVERTERS 051 1 1 2-1 29 (3)STRINGS TOTAL OLAR MODULE TYPICAL TO UTILITY GRID REVISIONS STRING #1 -2 DESCRIPTION DATE REV r- ---------------- - !-;- !- ENPHA5E t N ORIGINAL 08-18-2023 1 _ !4- - !-- BRANCH 1 TERMINATOR I- DIRECTIONAL 1 TYPICAL 0 UTILITY METER }-- ------------------ I-PHASE.240 V I 1 N POINT OF INTERCONNECTION 1 %{ PER NEC 240.21(B)(1)6 G90.G4(A)STRING #"' - - SHALL NOT EXC EDN �I O FT - 1 I al 4-- ] I 1 R CONTPACTO 240 V. 4IN 0V.200 A VICEDSCONNECf ELEMENT ENERGY, LLC. 2 ENPHASE BRANCH MICRO-INVERTER 7470 SOUND AVE 1 CIRCUIT CABLE TYPICAL ENP VACHA5E IQ8PLU5-72-2-US MATTITUCK, NY 1195 I 1 240 , I.21 A 97%CEC-WEIGHTED EFF. LICENSE# G74G I-HI NEMA G,UL LISTED 1 t ENPHA5E AC COM13INEP 4 AC DISCONNECT TYPICAL LICENSE # 52G89-ME 240 VAC.80 A 1 GATEWAY NEMA 31.UL LISTED 50 D D223NR5 (3)20 A DOUBLE POLE BREAKEP.5 24O VAC.GO A (I)15 A DOUBLE POLED NEMA 3R.UL LISTED �, POP,GATEWAWCOMMUNICATIOii DEVICE (2)50 A FUSES ' t of NE IV '2 'f GN '2 �_( GN ! P,`� OA �'v yO OA 1 20A i ISA C�22W G 50 A •- �- ----� 1 1 N N MAIN SERVICE PANEL m 1 I-PH.3-W240 O N ;2 LI -- B ----- s -------------------------------------- i 200AAC BOA r0344IN _ �QFESSIONP� c I I I I I j I I EXISTING GROUNDING PROJECT NAME ELECTRODE SYSTEM W Q � O Z Q m O L----------------------------- -------------� tu Q (Z - WIRE f CONDUIT SCHEDULE Lu ( Z z D L CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(%D I.D.# ORIGIN DESTINATION 51ZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DEBATE DISTANCE 310.15(B)(3) 310.15(5)(2a)/(3c) 0 LL_I D I INVERTERS COMBINER PANEL AWG#1 2 1 G 0.8 U5E-2/PV Wire AWG#8 I BARE CU FREE AIR 1" 559C 0.84 90 FT 2.840/0 N LLJ Ut OR EMT LU O 2 COMBINER PANEL AC DISCONNECT AWG#8 1 3 1 THWN-2 AWG#8 I THWN-2 CU PVC I., 45QC 0.95 30 FT 0.95% O j O = 3 AC DISCONNECT I MAIN PANEL AWG#G I 3 1 THWN-2 AWG#8 I THWN-2 CU PVC 1" 45QC 0.95 25 FT 0.2% U U m ( - U ELECTRICAL NOTES SHEET NAME CALCULATIONS POP CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL ,R OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I FV Source Circuit Wire Ampacity Calculation CONFIGURATION 3-LINE D I A. 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 902C WET ENVIRONMENT. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY [NEC G90.8(B)(I)]: (Isc)'(#of strings)'(I.5G) = 15.13 A Modules per String 10 MAX. TO, AND LOCATED AS CL05E AS P05515LE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#12,ampacity'Temp Derate= 20.1 G A Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 20.1 G A> 1 5.13 A,therefore DC wire size is valid. Number of Inverters 30 COMPLY WITH NEC 1 10.2G. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output' (1.25) =45.38 A Record low temp -I OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACE550RIE5 TO FULFILL AWG#8,ampacity'(femp Derate)'(Conduit Fill Derate) = 52.25 A Voc Temp Coefficient -0.24010/9C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 52.25 A>45.38 A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation O eratin Current 10.8 A N .T. . THE CONTRACTOR SHALL 512E THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) = 45.38 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampacity'(femp Derate)'(Conduit Fill Derate)= 71.25 A Operatincj Voltacle 37.4 V 5.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A>45.38 A,therefore AC wire size is valid. Max.System Voltage 49.G V SUPPORT PAIL, PEP THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.G.VIA WEEB LUG OR ILSCO GBL-4D5T LAY-IN LUG. AC SYSTEM SPECIFICATIONS SHEET NUMBER O.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positive/negative) Max AC Output Current 45.38 A OR O eratin AG Volta e 240 V P V-5 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-104.00-04.00-0 1 4.000 Zoho Sign bocument ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 SERVICE METER O O DESIGN B DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGYLLC t REVIEW BY J.M.NABCEP CERTIFIE ® � SOLARPVSYSTEM PHOTOVOLTAICPHOTOVOLTAIC SYSTEM ( 1 ) ALL LABEL SHALL BE INSTALLED IN 051112-129 EQU]PPFD1NiTH i SOLAR BREAKER s; DC DISCONNECT ACCORDANCE WITH THE 2017 NEC RAIDSHUTDOWN ® O• • REQUIREMENTS. RevisioNs DE5CRIPiION DATE REV OPERATING CURRENT A (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 08-18-2023 MAX SYSTEM SOLAR AC LOAD CENTER- OUTSIDE k iDO NOT RELOCATE THIS g , ,. VOLTAGE D REQUIRE FIELD VERIFICATION. j !OVERCURRENTDEVICE (3) LABELS, WAKNING(5) AND MARKING O TURN RAPID SHUTDOWN SWITCH TO O SHALL BE IN ACCORDANCE WITH NEC THE'OFF*POSMON70 SHUTDOWN 1 10.2 1 (B). ¢ PV SYSTEMAND REDUCE e --- CAUTION `- sHoc "AZAR°INTHEARRAY ELCISCONNECT POVVM,°MS5ERMEISAMMOPUM (4) THE MATERIAL USED FOR MARKING SOLAR AC LOAD CENTER- INSIDE 0 °'�°MCM "�°�S'°Y" MUST BE WEATHER RESISTANT, IN �Alv CONTRACTOR °,wn.,.�,Fx wtw eaten COMPLIANCE WITH NEC 1 10.2 1 (15)(3). --------- ----� ® w° O O O O ® (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. 4 7 8 1 1 R 7470 SOUND AVE TRISEQ)IIaAIENrFEDBY�auinPlE DUAL POWER SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 195 SOURCERTORLRATWGOFAM ! COMPLIANCE WITH NEC G90.3 1 . LICENSE # G74G I-HI OVERCURRENTDEMMS$EXCUlMG ; souRCES:unLTrYGRID ! LICENSE # 52G89-ME LMSUPPLYOWRCURRENT AND PV SOLAR DEVICE.SHALL NOT EXCEED ELECTRIC SYSTEM /- CONDUIT - INSIDE BUILDING OFBI Jm ,J �/� of NEW P oA 0 THIS SERVICE METER L' PHOTOVOLTAIC SYSTEM IS ALSO SERVED BY A ELECTRIC SHOCK HAZARD l 2 1 TER#JWALS ON THE UNEAh°O it COMBINER PANEL • PHOTOVOLTAIC SYSTEM i LOAD SIDES=Y BE ENERGIZED ';� DO NOT ADD LOADS j OA 103443 CONDUIT- OUTSIDE BUILDING I _W THE OPEN POSITION .� �� — ----.--- - .--- ROFESSIONP�' PROJECT NAME • w Lo I � • o U Q m 7�DUALLYLLJ AND eSTEM- - J — UI MAIN SERVICE PANEL - OUTSIDE O RCIRi✓iH I cn Lu zLgo W SDLARRECTRESYSEN Q (1) Oo w © PHOTOVOLTAIC n Q It m AC DISCONNECT 0 Ir— MAIN SERVICE PANEL - INSIDE I OPERATING (f) — U ` POWER SOURCE OPERATING VOLTAGE VOLTS L ® O it OUTPUT NOTRELOCATE THIS I, 1� ON DO NOT RELOCATE THIS ! SHEET NAME I_OVERCURRENT DEVICE ;! LABELS AC DISCONNECT/BREAKER DRAWING SCALE 000 ® ® N .T.S. SHEET NUMBER PV-6 TAX MAP: 1000- 104.00-04.00-014.000 XRR a i i s —-- —--------------- - - -- ——-_-- XR10 Mall XRIOO Dail XIR1000 Fall Bonded Splices 4.7 r <�1 r- A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow.I� solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability Self-drilling screws • Moderate load capability a Heavy load capability Extreme load capability o Varying versions for rails • Clear and black finish , Clear and black finish Clear anodized finish a Forms secure bonding UFOs j Stopper Sleeves Grounding Lugs Microinverter Kits I A ` ...Yd.. Universal Fastening Objects Snap onto the UFO to turn ys to Mount Mls or FOs to XR bond modules to rails. into a bonded end clamp. equipment ground. Flails. • Fully assembled & lubed a Bonds modules to rails , Low profile - Bonds devices to rails • Single, universal size a Sized to match modules , Single too! installation - Kit comes,assembled • Clear and black finish Clear and black finish o Mounts in any direction . Listed to UL 2733 Attachment. FlashFoot: Conduit Mount Slotted et Bonding Hardware ,.-• i l/ " s1 !f Flash and mount XR Flails Flas d mount conduit, - esign for rapid rail Bond and attach XR Flails with superior waterproofing. ut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases_i all o Twist-on Cap eases install ° Secure rail connections a T&Square Bolt options • Wind-driven rain tested o Wind-driven rain tested ° Slot for vertical adjusting a Nut uses 7/16"socket • Mill and black finish . Secures 3/a"or 1"conduit - Clear and black finish - Assembled and lubricated -- Resources, -- _ Design Assistant INABCIEP Certified Training Go from rough layout to fully --* Earn free continuing education credits, engineered system. For free. - while learning more about our systems. n �:r•n rr A26, I ®NRIDGE Fush Mount System I' Ile _N M717-2= r sy� Built toY solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. U9_ 2703 Listed System 20-Ycear Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. F:".:-%Yr�«^C�:..+�'g4`.1Sa�e'..�1'C4"�'li�`;"b'�4.}',,�.r-'S"tCJ'ix49R;'4'.ra"'.a:%fF4:r.`.ie:'`C:w?�Y�:.Nca6h::YJ'tee.kW-1��CIIr�i�-.3—'P-'—...1'E��Via A+�--c:.-�%Y%�=.'�'3i.�5�^'at'2c�'R::._A•fAGksuTw«-^�:�:.v:Y/-?s_:.5<;.Y MECHANICAL SPECIFICATION Format 74.0 in x 41.1in x 1.26 in(including frame) (1879 mm x 1045 mm x 32 mm) 74A•(Sar9mm) vsc(3sismm) 42.9'(1°aemml 'Weight 48.5lbs.(22.Okg) i rasa(lssomml rroni Corer 0.13 in(3.2 mm)thermally pre-stressed glass with - - anti-reflection technology 4aGwnMgpd°94a'(4amm) Fa° BacxCaver Composite film 39r(ssemm) Frame Black anodized aluminum 4u•tic45m,,,7 C=i! 6 x 22 manocrystalline Q.ANTUM solar half cells -` Junction Sox 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes `°0P� 44srtusomm) Cable 4mm2Solarcable;(+)>_49.2in(1250mm),H 2:49.2in(1250mm) .'-�--. •--�••- •"•._� - 4•M4° 9g-(t)E'rAILAI 1 Connector Staubli MC4;IP68 Lg6'(32mm) WAILA°.67(, lemur) OAT Cl4.Emn1 I�IQ73•la5mn) ELECTRICAL CHARACTERISTICS POWER CLASS 385 - 390 395 400 405 X,-37A14C=1 : 7ZS- Ci+,C'. !O iS,STCl(PO+NER TOLERANCE+51,V/-OW) =c raei at IL1+0p1 PMPP (W) 385 390 395 400 405 r'z circyt,Curre>.t, ---�- Isc [A] 11.04 11.07 1-1.10 1.1.14 11.17 Op rl ClreuR yoitag6 Voc [V] 45.19 45.23 45.27 45.30 T 45.34 Curre,'tt ai 4)PP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voit-ege at dr1PP VMPP IV] 36.36 36.62 36.88 37.13 37.39 E!Vc.cancyl 9 [%j >_19.6 >_19.9 >20.1 >_20.4 >_20.6 MlMI'10j N) AT 1;C AAAL OPERATING:.JN. " �.•;S,.+1:1;t0-r+ at YDR -T PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Sic.:Circuit C+mart Isc [A] 8.90 8.92 9.95 8.97 9.00 C7.a circuit Vni:aca Voc - IV] 42.62 42.65 42.69 42.72 42.76 Cilrrent a-, AVQ lmP (A) 8.35 8.41 8.46 8.51 8.57 -teas 3;IMIPP --, ✓MPP IV] 34.59 34.81 35.03 �- 35.25 '35.46 Measurement tolerances P_t3%;Isc;V«±5%at STC:1000 W/m',25±2°C,AM 1.5 according to IEC 60904-3.2800 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE -'0O -coals Rss9i__7_____,----_-_-_ At least 98%of nominal power during z >a. o .�=Y9�.�bure.,mmleY I p 9 'i first year.Thereafter max.0.5% y j __.___-.__.__________________ degradation per year.At least93.6% -c 199L--=------- of nominal power up to 10 years.At it 2 'least 86%of nominal power up to �= All data within measurement toleranc- es.Full warranties in accordance witham ifi- - B0 the warranty terms of the O CELLS 900 600 sales organisation of your respective o m m m country. _ �im.Ym°��aim:9w°�mm pans Typical module performance under low irradiance conditions in o comparison to STC conditions(25°C,JOOOW/m2) a' m TEMPERATURE COEFFICIENTS o 0 Tampa atur=Cneffictart of Isc a [%/Kl +0.04 -s•r.psrefurs Coeii�c;ert o;1j, d [%/K] -0.27 e!sre Coe'-HIaient of .,,• Y [%/Kl -0.34 tiorn at d;)adute Oeera?ing-:e;7 Narat4r NMOT [°F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN a - w NIS:(i num Systsm Voltage Vs [V] 1000(IEC)/1000(UL) PV module ciassi'hcation Class II o m ;)riaxirnum Serial Fuss Ra?sr,g [A DC] 20 Fire ga•:irg basarJ en A.Af51!UL 5:173 0 TYPE 2 m M=.Design Load,Push/Pail' [Ibs/ft2] 75(3600 Pa)/55(2660 Pa) Parrnittadj;Icdu)aTaniparature 40°Fupto+185°F c tile_-.Tes?Lead,Push!Pull' pbs/ft2] 113(5400Pa)/84(4000Pa) on Continuous Duty (-40°C up to+85°C) @ m 'See Installation Manual U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m a UL 61730,CE-compliant, 63• ® m Quality Controlled PV-Tl1V Rheinland, A `o-O I..:..:I IEC 61215:2016,IEC 61730:2016, _ m U.S.Patent No.9,893,215(so lar cells), SA® „7vw,dm�e :moo^ZOntal 76.4in 43.31n 48.Oin 1656lbs 24 24 32 QCPV Certification ongoing. Cc_.Us cacxag)r,g 1940mm 1100mm 1220mm 751kg pallets pallets modules UL 91)39 a tI11S2R17 •- -_--. _. _ - 9 a N Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618.USA I TEL+1 949 748 59 96 1 EMAI L inquiry@us.q-cells.com I WEB www.q-cells.us powered by ; DV6 1 v.: a Warranty ZflZ9 / O CELLS Product&P_wfortnance Yield Security BREAKING THE 20%EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE UIOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of �✓v the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent C_J low-light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID Technology',Hot-Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE!NVESTMENT Inclusive 25-year product warranty and 25-year lr linear performance warranty2. 'AFT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings CE LLS Engineered in Germany IQ8 and I08+ Microinverters Commonly used module pairings' w 235' 350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-W 29-45 Operating range V 25-48 25-58 Min/max start voltage V 36/48' 30/58 Max input DC voltage V 50 60 Max DC currentz(module[so] A 15 Overvoltage class DC part- II DC port backfeed current MA _0 PV array configuration 1x1 Ungrounded array No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA ,• ., Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range3 V 240/211-264 Max continuous output current A 121 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-.L)-branch circuit-• 16 13 Total harmcnicdistortion <5% Overvoltage class AC port III AC portbackfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption MAI 60 MECHANICAL DATA Ambient temperature range -40°C to+600C(-40°F to•140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2') Weight t08 kg(238Ibs) Cooling Natural convection-no fans Approved for wet ldcations .`- Pollution degree P03. Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C222 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IOBSP-DS-0002-01-EN-US-2022-03-17 ENPHASE, IQ8 and IQ8+ Microinverters Easy toknaair Our newest 108 Microinverters are the industry's first microgrid-forming,software- e. Lightweight andcompact with defined microinverters with split-phase power conversion capability to convert DC plu -n play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter - power Lfcte on is our proprietary application-specific integrated,circuit(AS1C3 which enables the (UaLO between cornporterlts microinverter to operate in grld-tiedor off-grid modes.Phis chip!isbuikt in advanced 55nm technology with high speed digital logic and has-super-fast response times „ €aster installation avith simple to changing loads and grid events,.alleviating constrains on,battery-sizing:for home taro-j*e cabling energy systems. HU-T nlw�ll�mil/ a @pro&ce•power evert when the s grid is dovoe ¢ ; Move than;one million cumulative a hoamof testing w lass IF.do&16-10sluiated Part of theEnphase Energy System,I08 Series 109 Series rAcroimrerteers redefine rehabifity emloSW& Vic►oinverters integrate with the Enphase tQ Batbam standardswits•mere than one millioncumntative high- Enphase IQ Gateway,and the Enphase App monitoring hours otpower-on testing,enabling an industry- m Optimized for the raf�St and analysis software. leading limited warranty of up to 25 years. pawed PV rRodules ll�tCLaiRrr711r1� Compfries with tEre latest advanced grid sepparV* Remote automatic updates for the latest gdd requirements Connect PV modules quickly and easily to IQ8 Series I08 Series MGcroinverters are UL Listed as Configurable to supportMicroinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with a wide cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. . hiteefs CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other 'Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. ' •'I08 and 1Q8Plus supports split phase,240V 108SP-DS-0002-01-EN-US-2022-03-17 installations only. 1E)' Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPE RBEIGCVBb Q U L5 0 Town of Southold OCt 2 4 2023 October 6th, 2023 Building Department Town Hall Annex 54375 Main Road Building Department P.O. Box 1179 Town of Southold Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Schultheis Residence 1360 Sterling Rd Cutchogue NY 11935 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.7 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. Great Eastern Services, Inc. P��O0 A���p PO Box 240 CO ��� 24 Harvey Rd * ..., Riverhead, NY 11901 2 z Mobile: 631.235.0189 Email: Iustra er AR 10344S jerrygiustra@gmail.com @9mail.com o�sstoN AMENDMENT �1 - 3/a 3 Zoho Sign Document ID:2A768FFA-FGRLLQUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 SCOPE Off WORK DE51GN$DRAFTING BY: ELEMENT ENERGY LLC TO INSTALL A 14.55 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT 5CMULTHE15 RESIDENCE, REVIEW BY J.M.NABCEP CEP.TIFIE Sheher Island O5 1 1 1 2-1 29 LOCATED AT 1 3GO STERLING RD,CUTCHOGUE, NY 1 1935. Heights" THE POWER GENERATED BY THE PV 5Y5TEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH 25 �J THE EXISTING ELECTRICAL SERVICE EQUIPMENT. Sheherlsland SWIM d REVISIONS , r . DE5CRIPTI0N DATE REV SYSTEM RATING paCoac REVISION 0-06-2023 A 14.58 kW DC 5TC 14 cutdioguuee North Haven 6 BAY POIMS., EQUIPMENT SUMMARY r�(Iv a- tuck'- New Suffolk ' oyack Sag Ha bor 3G QCELL Q.PEAK DUO ELK ML-G L 0+ 405 WATT PV MODULES 3G ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS Lauml 7. _ CONTRACTOR I IRONRIDGE XRI 00 MOUNTING SYSTEM J (" , •_ ELEMENT ENERGY, LLC. i r S I-I E ET INDEX 'Jamesp rtt Pv-1 COVER 7470 SOUND AVE sours teo` `� kfdridgq irnp'nr MATTITUCK, NY 1 1952 PV-2 51TE PLAN PROJECT LOCATION LICENSE# G74G 1-HI PV-3 ROOF PV LAYOUT LICENSE# 52G89-ME PV-4 STRUCTURAU DETAIL5 SECTIONS PV-5 3-LINE ELECTRICAL DIAGRAM PV-G LABELS pF N1r EV GOVERNING CODES CO�P?�0 A GiGs'ID ;0 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. u 2020 FIRE CODE OF NEW YORK STATE. A5CE 7-1 G AND NFPA-70. UNDERWRITERS LABORATORIES(UQ STANDARDS �O 103443 �(r� O5HA 29 CFR 1910.2G9 ARQ�SSIONP� GENERAL NOTES PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT 0 LU C� In THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE U_ U Q m HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK w 1- W 0 AGREE THE SAME. AERIAL VIEW p - 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED (1) (� APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP CZ �INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM Z z _1 AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, g L COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O W 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO LL.I (� ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. w� = O JURISDICTION. 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR -I O = 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS O WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE D_ U (9 j THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND (f) - (D CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. TH15 SHALL INCLUDE, BUT ARE NOT *ENT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, AM ND 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 5HEET NAME FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT 0) , COVE SPECIFICATIONS. CONSTRUCTION. _/o���-a�G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE r UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. t DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING20�3 CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES REGULATIONS BUf CONDITIONS PRIOR TO ORDERING MATERIALS AND 1C// 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN ng COMMENCING WITH WORK. a e CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S Of Of ba7 DRAWING SCALE 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. .d N .T.S. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. EXISTING WORK ADJACENT TO HI5.WORK, OR DAMAGED AS PV- I RESULT OF HIS WORK. TAX MAP: 1000-104.00-04.00-014.000 E I I Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 LEGEND TAX MAP: 1000-104.00-04.00-0 14.000 DESIGN 4 LNABCEF'CffPTlFlE ING BY: �DOSTING UTILITY METER N ELEMENT GY LLC MAIN SERVICE PANEL Do NEW PV SUB—PANELS / REVIEW BY05,1 1 A/C DISCONNECT COMBINER INVERTERS �/ ® GND ELECTRODE ' •27O Q REVISION5 DESCRIPTION DATE REV PV MODULE 240° 90'E PEV15ION 10-06-2023 A —RACKING RAIL 21po®r, 120° O ATTACHMENT POINT 18 0o 150o ---RAFTERS FROOF PITCH ANGLE MSUNRUN METER 36"x 3E"GROUND ACCESS TYP. ®VENT OPLUMBING VENT / ®'KY LIGHT EXISTING UTILITY METER 15TING MAIN ELECTRICAL SERVICE PANEL ®CHIMNEY NEW PV AC DISCONNECT / CONTRACTOR ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD CONDITION POTENTIAL SHADING ISSUES 7470 50UND AVE ❑TRIM/REMOVE AS NECESSARY (R ® MATTITUCK, NY 1 195 / LICENSE# G74G I-HI ® LICENSE# 52G89-ME NO ACCESS ROOF !!OF NE11 ACCESS ROOF m � _ w 51-8u SOAR 3445 � SS►oN / 18°SIRE SETBACK @RIDGE PROJECT NAME DZ° v Q m w w O LU o a _- � O 17'-10" 20- 1" � w J z on IL/ w N w LU U' o O O = L9 ° m D SHEET NAME 51TE PLAN 'NOTE I.)THE ROOF 5ETBACWATHWAY SHALL NOT BE REQUIRED ON ROOF-SLOPES WHERE THE DRAWING SCALE OPP05ING OR ADJACENT ROOF SLOPE 15 AN ACCE55 ROOF IN ACCORDANCE WITH R324.G.I EXCEPTION OF 2020 NY5 RESIDENTIAL CODE. I/ClQII __ I I CONSTRUCTION NOTES 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. �\ �_ 2.)ALL OUTDOOR EQUIPMENT 5HALL BE RAINTIGHT WITH MINIMUM NEMA 3R �/RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 CONSTRUCTION SUMMARY DESIGN 4 DRAFTING BY: (3G) QCELL Q.PEAK DUO BILK ML-G 1 O+ 405 WATT PV MODULES ELEMENT ENERGY LLC (DIMENSIONS: 74"X 4 1.1"X 1.3") (� REVIEW BY J.M.NABCEP CERTIFIE (3G) ENPHA5E IQ8PLUS-72-2-U5 MICRO INVERTERS �V 051112-129 (GO)ATTACHMENT POINTS @ G4"O.C. MAX. 0. (249.G) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. I REVISIONS ROOF TYPE: A5PHALT SHINGLE(SINGLE LAYER) DESCRIPtION DATE REV CONSTRUCTION NOTES 2�0 a REVI510N 10-OG-2023 A 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 240o �9p'E WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 210 o D 120o 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 150o MINIMUM NEMA 3R RATING. 180o 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE 3G"x 36"GROUND ACCE55 TYP. S FIELD VERIFICATION. EXISTING UTILITY METER j I5TING MAIN ELECTRICAL SERVICE PANEL NEW PV AC DISCONNECT CONTRACTOR ELEMENT ENERGY, LLC. ® ® 7470 SOUND AVE / // MATTITUCK, NY 1195 j ® LICENSE#G74G I-HI LICENSE# 52G59-ME ACCE55 ROOF OF NEIV Y ACCE55 ROOFir 2 rJ 101445 AR� ss%oNP� PROJECT NAME ° v Q m : z O G' ~ w _- 0 u� L z z � J g O w D G2 w V PANEL TYP. U-1cn Q H L LEGEND o z OEKISTING UTILITY METER m U I u MAIN SERVICE PANEL u TRING/CONNECTION TYP. 2-7 NEW PV SUB-PANELS A/C DISCONNECT COMBINER 5HEET NAME ARRAY#I ARRAY#2 INVERTERS 23 MODULES 13 MODULES GND ELECTRODE 22'PITCH 22'PITCH ICRO-INVERTERTYP. PV MODULE PV LAYOUT I G5o AZIMUTH I G5o AZIMUTH —RACKING RAIL o ATTACHMENT POINT ---RAFTERS DRAWING 5CALE —ROOF PITCH ANGLE MSUNRUN METER 1/CJ" = I 1-011 ®VENT 'NOTE 0PLUMBING VENT 1.)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE REQUIRED ON ROOF-SLOPES WHERE THE ®SKY LIGHT 5HEET NUMBER OPPOSING OR ADJACENT ROOF SLOPE 15 AN ®CHIMNEY ACCESS ROOF IN ACCORDANCE WITH R324.G.I ®COMPOSITE SHINGLES PV-3 GOOD EXCEPTION OF 2020 NYS RESIDENTIAL CODE. POTENTIAALL SHADING ISSUES TAX MAP: 1000-1 04.00-04.00-014.000 TRIM/REMOVE AS NECESSARY Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 LOAD CALCULATION ARRAY# ARRAY#2 ITEM DESCRIPTION ARRAYS#1-2 DESIGN£DRAFTING BY: RB Rid e Beam/Board 2"X 10" D. FIR ELEMENT ENERGY LLC R Rafter 2"X 8" D. FIR I G"O.C. REVIEW BY J.M.NABCEP CERTIFIE MODULE WEIGHT(Lbs) 45.4 48.4 (D) Deckin 5/8"PLYWOOD 051 1 12-129 #OF MODULES 23 13 K Knee Walls 2"X G" D. FIR A I G"O.C. TOTAL MODULE WEIGHT(Lbs) 113.2 629.2 (J Cellin Joist 2"X 8"D. FIR I G"O.C. REVISIONS (P) Pitch 22o DE5CRPTION DATE REV TOTAL LENGTH OF RAIL(Ft) 159.5 90.1 (H) Horizontal 5 an of R) 183"MAX REVISION 10-OG-2023 RAIL WEIGHT PER FOOT(Lbs) O.GB O.GB TOTAL RAIL WEIGHT 05) 105.5 61.3 (R) (RB) #OF STRANDOFF5 3G 24 WEIGHT PER STRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 72 48 TOTAL ARRAY WEIGHT(Lbs) 1293.7 735.5 POINT LOAD(Lbs) 35.9 30.6 CONTRACTOR TOTAL ARRAY AREA(Scl Ft) 492.4 275.3 ELEMENT ENERGY, LLC. 7470 SOUND AVE ARRAY DEAD LOAD(Lb5/5cl Ft) 2.9 2.7 ( ) MATTITUCK, NY 1195 WIND DE51GN SUBJECT TO DAMAGE FROM LICENSE# G74G I-HI GROUND SEISMIC WINTER ICE BARRIER AIR MEAN LICENSE# 52G89-ME SNOW DESIGN Frost DESIGN UNDEPJA FLOOD YMENT HAZARDSy FREEZING ANNUAL LOAD' Speed" Topographic Special Wndborne CATEGORY TEMP` REQUIRED' INDEXi TEMP (mph) effects (K) e vend region debris zone'" depth'I Weathering' I Termite` Hof NSty fEMA 20 140 NO NO NO B SEVERE 3 FT MOD TO 5°F YES ZONE X 599 5 I°F �Q�=gyp A G7Gs0,p� MANUAL DESIGN CRITERIA" (H) Indoor Elevation Latitude Winter Summer Altitude correction factor design Design temperature cooling Heatmg temperature (J) Z heating cooling tempera difference ture �O 103445 108 FT 41°N 15°F 861 F 1.00 70°F 75°F 55°F AROss1oNP� Wind Wind Winter Coincident 1 CZPROJECT NAME Cooling temperature difference velocity velocity Daily range Summer humidity _ heating cooling wet bulb humidity 1 ROOF FRAMING DETAIL � W Ln 15°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GP @50%PH U_ U Q m- g z Q In L J W IV For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth 1 j W z z strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,"moderate"or"severe"for concrete as pZ J determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. g D—/ LU b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction O (!7 LLI D shall fill in the frost line depth column with the minimum depth of footing below finish grade. to LLJ MODULE MOUNTING CLAMP C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. p = d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined soLAR MODULE w ~ on a site-specific basis in accordance with Section R301.2.1.4. d) C _ e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York BOLT AND NUT EL 3/8° EL _ U State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also O U m see Figure R301.2(1).] f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New NRIDGE ALUMINUM RAIL York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the ALUMINUM°L^BRACKET Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: SHEET NAME i.The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM FLASHING ii.Flood Boundary and Floodway Map(FBFM),and pp//�� iii.Related supporting data along with any revisions thereto. STRUCTURAL The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ASPHALT SHINGLE ROOF effects of ice damming,the jurisdiction shall fill in this part of the table with"YES:'Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5/I G"x G"STAINLESS I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WITH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" 2 1/2°MIN THREAD PENETRAT ON ICj. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method WITH GEOCEL 4500D DRAWING SCALE (Base 32°F)." (EQUIVALENT OR BETTER) k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the AS NOTED jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall indicate"NO"in this part of the table. I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. SHEET NUMBER n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. p\/_a o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at I v _1 elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. TAX MAP: 1000-104.00-04.00-0 14.000 MOUNTING DETAIL (') See Figure R301.2(4)B. Zoho Sign Document ID:2A768FFA-FGRLI-QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 50LAP ARRAY ON MAIN HOUSE 14.56 kW (3G)QCELL Q.PEAK DUO BILK ML-G 1 0+405 WATT PV MODULES DESIGN 4 DRAFTING B 0)STRING OF(13)MICRO-INVERTERS.0)STRING OF(1 2)MICRO-INVERTERS 6(1)STRING OF(1 1)MICRO-INVERTERS ELEMENT ENERGY LLC '(3)STRINGS TOTAL REVIEW BY J.M.NABCEP CERTIFIE 051112-129 STRING#I r- ------------ - - _ _ _ _ - - - - - - -- -- - - - - - - - - - - - - - - - - - - - - - MICRO-INVERTER REVISIONS 1 ENPHASE 108PLU5-72-2-U5 DESCRIPTION DATE REV -_-- 240 VAC,1.21 A -_-- 97%CEGWFJGHTED FFF. REVISION I0-06-2023 A I ---- ---- ---- ---- ---- ---- ---- ---- ---- NEMA G.UL LISTED I YPI_AL I I STRING#2 _ ---------- - FIJPHASE r - - - - - - - - - - - - - - BRAN I - - - - - - - - TERMINATOR I TYPICAL ------------- ---- ---- ---- 1 I ---- ---- ---- ---- ---- ---- ---- ---0LAR MODULE TYPICAL ( I TO UTILITY GRID 1 I I I STRING#3 -_ - -_ _- -_ _ _- -_ -_ _- 1 -------- - BI-DIRECTIONAL CONTRACTOR 1(91 PH 1IA5E.2 OV ELEMENT ENERGY, LLC. -- ---------- ---- ---- - -- ---- - -- ---- ---- ---- ---- ---- 7470 SOUND AVE 1 N ENPHASE BRANCH P�"°F2�2i('_7(�)'6Y.ea(A) MATTITUCK, NY 1195 ( I I CIRCUIT CABLE TYPICAL � Na W t_NDO LICENSE#G74G I-HI LICENSE# 52G(59-ME I I I I I I VN O V.RVIC:DISC NV C;2 OF NEW 2DIA 1 o A Gi O� I I UA. n LI103445 p t t ARQFESSIONA� 1 I MAIN SERVICE PANEL AC OI5CONNECT PROJECT NAME a AAc SO D D22311R5 Q 1^ AC COMBINER BOX N Lf J 240 VAS.d:s 240 VAC,60 A W DnA 31 JL 11-1 NEMA 3R ILL N5TED G , C) G N T 13; ADN&_ra.£8�.:.v.a� �(2)COA FU5F5 1I I II � 60A E T Uz O ELECTRODE 5Y5TFM `W LLI _L ~ I M M i LU Z z L---------------------------------------------V------------------- p p �^^,, 11 1 0 WIRE$CONDUIT SCHEDULE LD LU rFW- CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% LLI v, Q I.D.# ORIGIN DESTINATION 517E PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE 517E TEMP DEBATE DISTANCE O J O = 310.15(B)(31 310.15(B)(2a)I(3d r ` I INVERTERS COMBINER PANEL AWG#12 1 G I U5E-2/PV Wire AWG#8 1 BARE CU FREE EAI MT I° 55aC 0.84 80 FT 2.0% O Ir- 2 W COMBINER PANEL AC DISCONNECT AWG#G 1 3 1 THWN-2 AWG#8 1 THN-2 CU PVC I" 45aC 0.95 25 FT 0.5% U m 3 AC DISCONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45aC 1 0.95 1 10 FT 0.2% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE U5TED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC G90.8(5)())]:(Isc)'(#of strings)'(1.5G)= 19.GG A Modules per String 13 MAX, 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY AWG#12,ampacity'Temp Derate= 20.1 G A TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. 20.1 G A> 19.GG A,therefore DC wire size is valid. Modules per Inverter 1 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL #2 Inverter Output Wire Ampaclty Calculation Number of Inverters 3G COMPLY WITH NEC 110.2G. It Maxera e out ut'(1.25)=54.45 A Record low temp I CDC 5.)DRAWINGS INDICATE THE GENERAL AR Inverter axmP 9 P RANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550RIE5 TO FULFILL AWG#G,ampacity'(Temp Derate)'(Conduit Fill Derate)= 71.25 A Voc Temp Coefficient -0.24%/°C DRAWING SCALE 71.25 A>54.45 A,therefore AC wire size 1s valid. APPLICABLE CODES AND STANDARDS. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampaclty Calculation Operatincj Current 10.5 A N .T.S. THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25)= 54.45 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampacity'(Temp Derate)'(Conduit Fill Derate)=71.25 A Oreratinel Voltacle 37.4 V 5.)MODULE GROUNDING CUPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A>54.45 A,therefore AC wire size is valid. Max.System Voltacje 49.G V SUPPORT RAIL,PER THE GROUNDING CUP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR I1-500 G5L-4D5T LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS I5(positive/negative) Max AC Output Current 54.45 A PV-5 OR Operatincl AC Vol acle 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-104.00-04.00-0 1 4.000 Zoho Sign Document ID:2A768FFA-FGRLI_QUVEM7YHSVDHFQ6ZQVNPEBQNJRB9KIGILWQ51 DESIGN 4 DRAFTING BY: O - - O ELEMENT ENERGY LLC SERVICE METER INSTALLATION NOTE REVIEW BY J.M.NABCEP CE RTIFIE 051112-12 ® � SOLARFVSYSTEM j PHOTOVOLTAIC - • • • ( I ) ALL LABEL SHALL BE INSTALLED IN EQUIPPED WITH I�SOLAR BREAKER •, DC DISCONNECT ACCORDANCE WITH THE 2017 NEC REVISIONS RAPID SHUTDO N 0 •• • � � REQ U I REM ENTS. °�`��°N °A� �� 8 OPERATING REV1510N 10-OG-202s A (2) ALL LOCATIONS ARE APPROXIMATE AND SOLAR AC LOAD CENTER- OUTSIDE DONOTRELOCATETHISI •MAX S�STEM VOLTAGE REQUIRE FIELD VERIFICATION. s oVERCURRENrDEVICE°, (3) LABELS, WARNINGS) AND MARKING ® SHALL BE IN ACCORDANCE WITH NEC O TURN RAPID SHUTDOWN SWITCH TO O THE'OFF'POSITION TO SHUT DOWN 1 1 0.2 1 (B). i PV SYSTEMAND REDUCE e j CAUTION SHOCK HaM INTHEARRAY A_C DISCONNECT TOTMSSERV= � (4) THE MATERIAL USED FOR MARKING r FROM THE FOLLOWINGSOUROESWRN i DWONNEC51DC17EDASSHMM MUST BE WEATHER RESISTANT, IN ® CONTRACTOR SOLAR AC LOAD CENTER- INSIDE 2 I COMPLIANCE WITH NEC 110.2 I (B)(3). ELEMENT ENERGY, LLC. w (5) THE PV SYSTEM CIRCUIT CONDUCTORS 7470 SOUND AVE O O O O ® TYP- SHALL BE LABELED INSTALLEDLICENSE# MATTITU IN , NY I 1 95 THIS EQUIPMENT FED DUAL POWER SUPPLY LICENSE 6746 I-111 ID LICENSE# 52689-ME �uRCES.TOTALRATINGOFALL COMPLIANCE WITH NEC 690.3 1 OVERCURRENTDEVICES.EXCLUDWG SOURCES:UTILITY GRID , MAIN SUPPLY OVERCURRENT AND PV SOLAR DEVICE,SHALL NOT EXCEED ELECTRIC SYSTEM Of NEw CONDUIT - INSIDE BUILDING aecPacrn°Fsus m �o A Gp� d� THIS SERVICE METER m W tl` IS ALSO SERVED BY A 9 2 2 ELECTRIC SHOCK HAZARD. 11 PHOTOVOLTAIC SYSTEM = PHOTOVOLTAIC SYSTEM Ul ?� TERMINALS ON THE LINE AND ! COMBINER PANEL OA 3 0344 Ki LOAD SIDES MAY BE ENERGIZED I DO NOT ADD LOADS SSI( CONDUIT - OUTSIDE BUILDING --IN THE OPEN POSITION 4 © PROJECT NAME -7.on• • U- U Q c0 7SCOURCES- 7GRUDAND w W Q7Un=UTY UJ---- -----, (n LLI Z z MAIN SERVICE PANEL - OUTSIDE O J � AU iOiVSi)LARC# O w L N ILI I-- CD O O ® 00 ACA I o (s) O SOLAR ELECTRIC SYSTEM CDNNECTED O (,D MAIN SERVICE PANEL- INSIDE �, '• POWER SOURCE I SHEET NAME OUTPUT CONNECTIONDO NOT 6I ® O I CURRENT DEVICE OVEE J� - LABELS AC D15CONNIfCT/I3REAKER DRAWING SCALE 000 � ® N .T.S. SHEET NUMBER PV-6" TAX MAP: 1000-104.00-04.00-014.000 SCO I E Of WORK -___ - - - -- -- --- - - 1GN 3 DRAFTING BY: LLG TO INSTALL A 40 KW BATTERY ENERGY STORAGE SYSTEM AT SCHULTHEIS RESIDENCE, or oa Nt s s 1!7 ELEMENTENERGY GE IFI tau sca Mus Ana - - . '.. LOCATED AT 1360 STERLING ROAD, CUTCHOGUE, NY 11935. [PREV:IEWJ.M.M NABCEP C RT E TH15 BATTERY ENERGY STORAGE SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID _ _ O5 1 1 1 2-1 29 THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS _ DE5MP7I0N DATE REV SYSTEM RAT I N G -o d`. ORIGINAL 2/7/2024 - /- , 40 kW AC STC � 1 I EQUIPMENT SUMMARY P `L 2 UNIT OF 50NNEN 50NNENCORE+40KWH BATTERY ENERGY STORAGE - -- —'- SHEET INDEX t..., s CONTRACTOR Pv-I COVER ELEMENT ENERGY, LLC. PV-3 FLOOR PLAN :s rt3' s 7470 SOUND AVE PV-4 ELECTRICAL DIAGRAM ^': MATTITUCK, NY 1 195 PROJECT LOCATION LICENSE # G74G 1-11I �t LICENSE # 52G89-ME 'GOVERNING CODES �` ' '"� ��fL' `�'' w '20 1 7 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. % F- 2020 BUILDING CODE OF NEW YORK STATE. F E B 2 2 2024 2020 FIRE CODE OF NEW YORK STATE. ` ASCE 7-1 G AND NFPA-70. UNDERWRITERS LABORATORIES(UL)STANDARDS '} S 'Ter YffG D zIT11T. 'OSHA 29 CFR 1 910.2G9 GENERAL NOTES _ PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT t > LLJ C) In THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE '.` U Q co HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK z O In AGREE THE SAME. AERIAL VIEW ',u- Q 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP "-' z INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, J z _ __ __ � AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. C IL/OPERATION, ETC. ADEQUATE FOR THE PURPOSES O uJ 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO N W F- U ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. o _ (� JURISDICTION. 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR N J 0 LO 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS O � WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE O = Lq CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE m U ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, SHEET NAME SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY F ALL STRUCTURAL STEEL SHALL BE LATEST A.I.S.0 AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT F Nell/ FABRICATED AND INSTALLED AS PER LATE �i� COVE CONSTRUCTION. SPECIFICATIONS. ll .1 O 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE eDE b G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE ti`. ��O DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING e N UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. 4 r CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES�REGULATIONS n eq� CONDITIONS PRIOR TO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN m •�r: � COMMENCING WITH WORK. Z I'• DRAWING5CALE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS � CERTIFICATION OF THESE PLANS. O O� WORK FROM THE SITE AND DISPOSE Of 5.THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND IN A LEGAL MANNER ON N .T.S. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THER A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. RO�SS �P\- PROJECT FOP,WHICH THEY ARE ETION OF WORK,THE SITE TO BE CLEAREDE MADE I5 EXECUTED OR NOT. 14. AT THE COMPLETION THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 5HEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS PV- I RESULT OF HIS WORK. - TAX MAP: 1000- 104.00-04.00-014.000 CONSTRUCTION NOTES CONSTRUCTION SUMMARY DEIGN£DRAPING BY: 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE (2) UNIT OF SONNEN 50NNENCOP.E+ 40KWH BATTERIES ELEMENT ENERGY LLC WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. (DIMENSIONS: 27.08"X 63.28"X 13.85") IN FIRE RATED REVIEW BY J.M.NABCEP CERTIFIE 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH ROOM 051 1 12-1 29 MINIMUM NTI RATING. SONNEN 50NNENCOKE+ 20KW BESS UNITS 3.) ALL LOCATIONS NSS AREARE APPROXIMATE AND REQUIRE REVISIONS FIELD VERIFICATION. — 4.)CONDUIT RUN/RACEWAY FOR DESCRIPTION DATE REV BATTERY ENERGY ORIGINAL 2/7/2024 STORAGE SYSTEM (BESS)SHALL BE LOCATED WITHIN PVC.THE CONDUIT/WIKE RUNS TO THE EXISTING MAIN SERVICE PANEL AND TO THE PLP IN PVC CONDUIT SHALL BE LOCATED INDOORS. 5.)THE BESS IS LOCATED IN THE EXISTING GARAGE. 6.)THE BATTERY LOCATION FOR THIS PROJECT MUST ADHERE TO THE FIRE SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE FIRE CODE(NYS FIRE CODE R302). I 7 IT IS IMPERATIVE THAT THE EXISTING GARAGE BE INSPECTED AND APPROVED BY THE DESIGNATED FIRE DE ENFORCER TO ENSURE COMPLIANCE. PLEASE BE CONTRACTOR ADVISED THAT WHILE WE ARE NOT CERTIFYING THE C. LL T ENERGY, ENCLOSURE OURSELVES, IT IS UNDERSTOOD THAT IT ELEMENT SOUND LL MUST MEET THE AFOREMENTIONED FIRE CODE I REGULATIONS. MATTITUCK, NY 1195 LICENSE # G74G 1-HI LICENSE # 52689-ME XISTING GARAGE DOOR PROJECT NAME ° U Q m w �'n kJ O m g � � o w cn w 1-- 6) 0 Lo _ LEGEND IL_ = ®EXISTING UTILITY METER m MAIN SERVICE PANEL NEW PV SUB-PANELS A/C DISCONNECT - COMBINER SHEET NAME XISTING UTILITY METER INVERTERS GND ELECTRODE NEw y -lPV MODULE PV LAYOUT �FRoff, jrO � —RACIONG RAIL o ATTACHMENT POINT ---RAFTERS CT DRAWING SCALE !lj --*--ROOF PITCH ANGLE e`_ Z ycP�O O, p2 i ®/ SUNRUN METER /�11 _ I 1_O 1 5 ®VENT [GARAGE PLAN FOR BESS AND FIRE RATED ENCLOSURE] A�''o �O��� OPLUMBING VENT ®SKY LIGHT SHEET NJMBER ®CHIMNEY COMPOSITE SHINGLES PV—3 GOOD CONDITION TAX MAP: 1000-104.00-04.00-014.000 POTENTIAL SHADING ISSUES �'` �TRIM/REMOVE AS NECESSAR ------- EXISTING — —'------------ DESIGN 5 DRAFTING BY: I (N)ENPHASE I ELEMENT ENERGY LLC COMBINER BOX MODEL REVIEW BY J.M.NABCEP CERTIFIE 2-#12 AWG SKU:0.12-RAW-300,THWN NO#X2-IQ-AM1-240A I ESSENTIAL PLUS- PANE BSI 112-129 (13)IQBPLUS-72-2-US-1 1-#8 AWG,BARE COPPER GROUND PH 12OA DPANEL MICROINVERTERS CELL WIRE LESS I (E)1DDABREAKER BRANCH-1 MODEM COMMS 13 HANWHA QCELLS:Q.PEAK I (TOP FED) DUO ELK ML-G70+405 I RE V1510N5 IQ GATEWAY I — 4 DE5CRIFTI0N DATE REV I ) (C DISBOACONNECT FUSED (12)IQBPLUS-72-&US ro AC DISCONNECT j ORIGINAL - 2/7/2024` MICROINVERTERS SQUARE D D322NRB I m/� ----- BRANCH4 (N211� WITH 60 A FUSES, I TO OTHER LOAD ri1 12HANWRAQCELLS:Q.PEAK KNIFEBLADE, I - DUO BLKML-G70+405 (N12DA� LOCKABLE,NEMA 3R, (11)IQSPLUS-72-2-US (N)�� UL LISTED MICROINVERTERS - _ I j I �b I BRANCH-1 - - 11-HANWHA QCELLS:Q.PEAK (E)UTILITY METER ) — __ DUO ELK ML-G70+405 I i (N)200AAC j 6-912 AWG SKU:Q-12-RAWJOD,THWN 1-#8 AWG,BARE COPPER GROUND I I CONNECTIONS MODULE I O I 3-#12 AWG,THWN i. 3-#2 AWG,TH NN 1-08 EGC,THWN 1-08 EGC,THWN CONTRACTOR• •o IN 3/4"PVC CONDUIT I IN 1-114"PVC CONDUIT I----------------------- ------------------------------------ ELEMENT ENERGY, LLC. 7470 SOUND AVE MATTITUCK, NY 1 195 ro UTILITY , LICENSE# G74G I-HI UNDERGROUND LICENSE# 52G89-ME FEED I_ 1242DD RATED �. IN SER EPANELM - 1 PH.f 620Y 60iQ 0 0 EXISTING WIRE RUTA A/2P MAIN E,GROUNDING ELECTRODE THROUGH CONDUIT BREAKER (TOP FED) 3-#310 AWG,THVWi J{ CONDUCTOR 66 BARE COPPER 1-#4 EGC,THWN IN T PVC CONDUIT rmm\ r\ • IN)100A MICRO GRID SUB PANEL PROJECT NAM` U Q m z 0 m (N)40A 12 W (L-.I GENERAL NOTES W Z N)40A/2P z I.)THE BE55 PROVIDES MONITORING AND BALANCING CELL 5-#BAWG,THWN Qcz SONNENCORE+ESS SONNENCORE+ESS 1-08 EGC,THWN J ,^ VOLTAGES,CURRENTS,AND TEMPERATURES WITHIN THE IN1'PVCCONDUIT 0 U) W SCORE-P20 SCORE-P20 3-tt2 AWG,THWN MANUFACTURER'S SPECIFICATION THROUGH WEB AND MOBILE 20kWh240V 20kWh240V 1-#8EGC,THWN lLJ IN 1-114•PVC CONDUIT APPLICATIONS. � C� 2.)THE HEAT DETECTOR OR HEAT ALARM 5HALL BE IN5TALLED AND C7 � 0 O J O INTERCONNECTED WITH SMOKE ALARM AND THE BESS SYSTEM "' �" "'�" L SHALL TRANSMIT AN ALARM 51GNAL VIA MOBILE PORTAL OR THE L SMOKE AND/OR HEAT ALARM/DETECTOR IF POTENTIALLY — O � m � HAZARDOUS TEMPERATURES OR OTHER CONDITIONS SUCH AS = _ u 5HORT CIRCUITS,OVER VOLTAGE OR UNDER VOLTAGE ARE DETECTED. _ SHEET NAME 3 LINE DIA. �O SONNEN EONNEll OF NEIV (N)100A GRID SUB PANEL J UEFj� YO DRAWING SCALE (N)30A/2P r �� I NOTE: N .T.S. (N)30A/2P Ity� 1)CONDUITAND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS >� AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. IF 5-#tO AWG,THWN �A!) SHEET NUMBER 1-#8 EGC,THW .•,env �.ION. A IN N 3/4"PVC CONDUIT 3-96 AWG,THWN �\ / 1-#8 EGC,THWN v 4 IN i'PVC CONDUIT TAX MAP: 1000- 104.00-04.00-014.000 February Sth,2024 Town of Southold Building Department Town Hall Annex 54375 Main Road PO.Box 1179 Southold,New York 11971-0959 u ed S a an I a he Ncs esid ce 3 li60 S e C o ue Subject:R of Y 11935 To Town of Southold: I hereby affirm that,following a comprehensive professional evaluation,the plans for the installation of the Battery Energy Storage System(BESS)and its associated fire-rated enclosure comply with the 2020 Residential Code of New York State,the 2020 Building Code of New York State,the 2020 Fire Code of New York State,the 2017 National Electric Co a de a in sSCEtrict 7-16,and other relevant industry standards and regulations.This certification is p adherence to the governing regulations and standards applicable to such installations. The mounting locations and methods detailed in the submitted plans have undergone thorough scrutiny and are confirmed to align with the requisite codes and standards.Thepo Po sed BESS,utilizing Lithium Iron Phosphate technology,adheres to UL9540A standards,ensuring it does not exhibit thermal runaway.Furthermore,the enclosure is meticulously designed to be fire-resistant in accordance with R327 of the NYS Building Code. In my professional opinion,derived from the site inspection and detailed analysis,the proposed BESS and the accompanying enclosure system demonstrate structural adequacy to withstand j, the reactions associated with the BESS. Please contact me if you have any questions or comments about the above. Sincere �OF NE(yY James ski ` `rko ,PE "r ssoER�o0p� y 260 Deer Drive Mattituck,NY 1195` 0 Z = � 631-774-7355 w,,,�5'�• AR�FES510 i t SCOPE OF WORK TO INSTALL A 40 KW BATTERY ENERGY STORAGE SYSTEM AT SCHULTHEIS RESIDENCE, ` ELEMcnT Enter L:t LOCATED AT 13GO 5TERUNG ROAD,CUTCHOGUE,NY I 1935. _ REV!EW DYJ.M. THIS BATTERY ENERGY STORAGE SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID � + �� 05 1 1 12-1 2- ` - —_ THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS &�_lncw rwre Rev SYSTEM RATING ; ' OPJGnIAL --202027— 40 kW AC 5TC EQUIPMENT SUMMARY 2 UNIT OF 5ONNEN SONNENCORE+40KWH BATTERY ENERGY STORAGE . ; — ---- --- SHEET INDEX Pv-I COVER I ELEMENT ENERGY,LLC PV-3 FLOOR PLAN 1 7470 SOUND AVE w 4 ELECTRICAL DIAGRAM _`�.L_e� MATTITUCK,NY 1 195 PROJECT LOCATION LICENSE#G74G1-HI LICENSE#52G89-ME GOVERNING CODES .� 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. I w t 2020 BUILDING CODE OF NEW YORK STATE. - j 2020 FIRE CODE OF NEW YORK STATE. A5CE 7-I G AND NFPA-70. UNDERWRITERS LABORATORIES(UU STANDARDS OSHA 29 CFR 1910.2G9 GENERAL NOTES I.CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS NAMEONS AT � THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE O U Q m HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK w W 2.COAGRE TRACTOR. AERIAL VIEW t0 _2.CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED tH N � [, APPROVALS,PERMITS,CERTIFICATES OF OCCUPANCY, - - - - -- - -- Y a)- INSPECTION U APPROVALS,ETC.,FOR WORK PERFORMED FROM 10.CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE,I.E. TOWN COMMENTS AND APPROVAL STAMP z Z AGENCIES HAVING JUR15DICTION THEREOF,IF REQUIRED. CONTRACTORS LIABILITY,WORKMAN5 COMPENSATION, 3.ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION,ETC.ADEQUATE FOR THE PURP05E5 (n CZ LL ALL RULES AND REGULATION5 OF THE RESPONSIBLE OF TH15 PROJECT AND FURNISH PROOF OF SAME PRIOR TO LIO W JURISDICTION. COMMENCING WITH WORK p H O 4.IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I 1.EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR w WHICH 015AGREE5 WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE " ' - --- -- R�� �--t O 1) O U THE CONTRACTOR 5HALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS p = ENGINEER.SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND w � (h u CONTINUE WITH THE WORK,HE SHALL A55UME ALL HEALTH ADMINISTRATION.TH15 SHALL INCLUDE,BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO:PROVIDING FOR ADEQUATE AND PROPER BRACING, 5.ALL STRUCTURAL STEEL 5HALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY BRI 1 sneLrNAMe FACATED AND INSTALLED AS PER LATEST A.I. .0 SCAFFOLDING,STAIRS,ETC..AS WELL AS PERMANENT - - S S CONSTRUCTION. ..-.` i.I . ! I -�� F NFk, COVER SPECIFICATIONS. 12.FIGURED DIMENSIONS SHALL GOVERN.DO NOT SCALE 1 i P.S J DSE/ 1-0 6.ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE �; 1'q-O �� DRAWINGS,WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C.6 A, NY5 CODES t REGULATIONS CONDITIONS.EACH CONTRACTOR SHALL VERIFY EXISTING r. x 7.ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND "" O ( cam: -' of CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. F E B 2 6 2024 rn z ''� � CERTIFICATION OF THESE PLANS. 13.CONTRACTOR TO REMOVE ALL DEBR15 CREATED BY THIS U'� "-' 2 DRAWING SCALE e.THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON OA 0> SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEK14.AT LY BASIS ASISCOM O 50ONER IF CONDITIONS ON WORK,THE SITE WARRANT.B ARED ROAFgg N.T.S. PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY 15 TO BE d t "THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR EXTENSIONS TO TH15 PROJECT LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE 9.CONTRACTOR SHALL PROTECT,PATCH AND REPAIR ALL TOTAL SAT15FACTION OF THE OWNER PRIOR TO RELEASE OF y�l'"r:C p- �; _ $Y I NLA!BER EXISTING WORK ADJACENT TO HIS WORK,OR DAMAGED AS FINAL PAYMENT. P ' RESULT OF H15 WORK. - TAX MAP: 1000-104.00-04.00-014.000 r j CONSTRUCTION NOTES CON5TRUCrION SUMMARY DESIGKS ORAFfIKG BY: I.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE (2)UNIT OF 50NNEN 5ONNENCORE+40rWH BATTERIES - EIEN.EN7 ENErcrlt^ Wffh THE MANUFACTURERS INSTALLATION INSTRUCTIONS. (DIMENSIONS:27.08-X G3.28°X 13.85')IN FIRE RATED REVIEW BVlN NAB,.-EE CMIfIE 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH ROOM 051 1 12�129 3.)ALLMINIMUM NATI S RE AP.. 50NNEN 50NNENCORf+ 20KW BE55 UNITS 3J ALL LOCATIONS ARE APPROXIMATE AND REQUIRE _ REVISIONS,_ _ FIELD VERIFICATION. - . G'v�LpffgN DAm'-REV 4.)CONDUIT RUWRACEWAY FOR BATTERY ENERGY - ORIGINAL -277l2024"-_ STORAGE SYSTEM(BE55)SHALL BE LOCATED WITHIN PVC. THE CONDUITIWIRE RUNS TO THE EXISTING MAIN SERVICE PANEL AND TO THE PUP IN PVC CONDUIT SHALL BE LOCATED INDOORS. - - ---- -' 5.)THE BE55 15 LOCATED IN THE EXISTING GARAGE. - - ------- 6J THE BATTERY LOCATION FOR THIS PROJECT MUST - ADHERE TO THE FIRE SAFETY STANDARDS OUTUNED IN THE NEW YORK STATE FIRE CODE(NY5 FIRE CODE R302). R 15 IMPERATIVE THAT THE EXISTING GARAGE BE - INSPECTED AND APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO ENSURE COMPUANCE.PLEASE BE I raA7RATOR ADVISED THAT WHILE WE ARE NOT CERTIFYING THE ELEMEM ENERGY LLC. ENCLOSURE OURSELVES,IT 15 UNDERSTOOD THAT IT , 7470 SOUND MUST MEET THE AFOREMENTIONED FIRE CODE I MATTITUCK,NY 1195 AVE REGULATIONS. LICENSE#G74G I-HI LICENSE#52G89-ME I I 15TING GARAGE DOOR I P P=NAVE ° uJ Q m w w p m I � to z Z 0 (17 W W FW- w U) O LEGEND 0- = F �om'I UmJtt YETFIt d m YAO!gRN¢PANEL anV PP ISTING UTILITY METER m B'1ECT NAVE -QID ELECTRODE NEwyo QPVYDUE PV LAYOUT tEf dp —RAWIG PNL C --- � n w ROF RIDE M= ORAWNG rGA f 2 - 2 NCO `O' `:. ={j esulNAm L¢mR /411 = 1 1-01 [GARAGE PLAN FOR BE55 AND FIRE RATED ENCLOSURE] ®PLUN®m w r O gl AN ® SHEET NIMBER CIEIDET mcw PV-3 TAX MAP: 1000-104.00-04.00-014.000 ❑T��I¢L1GwE As R • nvnc0.•n.n I�--------------------------- --------------- --------------^) __DESIGN I,DRAFTING BY-. - IINENT•WLSE - _ COMBINER Bmt MODFl - I' f1EN1M,NABC&DE I (t�naWUSR3La— NOORJOANI-]OM 1 �'°°["n'� 1 CRG�YIERi�S q xC�gyi[coDpEq T,ggnp 1 REVIN/BY J.M.NABCEP GERiIFIEC 1 OSII12-12? 1 1)1N DPEAK NOpEu I '[M[w Y¢ ouoeu[c.elaas I REVISION5 . 1 (N)BDA FUSED _ 1 1[Y air AC DISCONNECT 1 IGSLwPnON 12O RN ns I oRlGuui 2!l/202'4' - 1 SQUARE D MWM I NTli6DAf1SES. 1 nuu - aaoEAc WFEBIADE DUDBuc[aaiairo LOCKABLE,NEMA3R. I on— UL LISTED 1 1 I — 1 avo, I (Mzronnc u�Y,T+.Rwecovc[n ta�glroTmm 1 DDMDDULE NS I I A'ODULE 1 rw-wccau r 1 'pugT . CONTRA.'TOR 1 wl-wwc 1--———————————————————— -------------------------------- ELEMENT ENERGY,LLC 5. 7470 SOUND I MAITITUCK,NY 119 AVE m umm UCEN5E#G74G 1-1-1 1NpEAGRO11'm - LICENSE#52GI59-ME FEED A>�1 t /� wSPVC WMUR Dn,w[wdtD GRa alb vulEt PROJECT NAME _- ° U Q m a ~ o O m GENERAL NOTES K z Z I.)THE BE. PROVIDES AND TEM LNG AND BALANCING CELL SaNNENmRE.ESS SOUNENCORE.ESS .®�R[ww w,w, J VOLTAGES,CURRENTS,AND TEMPERATURES WNHIN THE WE aW bCOREi]L a Aa[�R[rNm 5 (n W ILJ MANUFACTURERS SPECIFICATION THROUGH WEB AND MOBILE APPUCATION5. � FveTamuR N W {— D 2.)THE HEAT DETECTOR OR HEAT ALARM SHALL BE IN5TALLED AND (J� INTERCONNECTED WITH SMOKE ALARM AND THE BESS SYSTEM v N J SHALLTRANSMR AN ALARM SIGNAL VIA MOBILE PORTAL OR THE 0 C) U SMOKE AND/OR HEAT AIARMJDETECTOR IF POTENTIALLY HAZARDOUS TEMPERATURES OR OTHER CONDMON5 SUCH AS — j v _ L m Z3 SHORT CIRCUFT5,OVER VOLTAGE OR UNDER VOLTAGE ARE DETECTED. SH`ET NAME 3 LINE DIA. OF.IUE�h, Li u ` F!^,FON� DRA'MNG SINE NOTE: N.T.S. )CONDUITAND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS "��' "YUJI AND ARE NOT MEANT TO OMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. u[ - I lu Ewq� '\!r .JnF ��. SHE'T NUMBER [[wwowueT .[e.wR T,nw �� S10�n ate, PV-4 TAX MAP: 1000-104.00-04.00-0 14.000 � Le 4u�ryr8t�,2b24� ,� I ;1 •, Town of Southold I f Building Department F E g 2 2 2024 Town Hall Annex 54375 Main Road _-;- P.O. Box 1179 - ' Southold, New York 11971-0959 Subject: Roof lUl ted:So ar Paneis.at_the Sc -ultheis Residence 1360 Sterlin Rd.Cutc o ue J ou NY_5 To Town of Southold: I hereby affirm that,following a comprghensi�e p(BE-88 and suassoc aced fire-rated ation,the plans for e installation of the Battery Energy-Storage System (B: ) enclosure comply with the 2020 Residential Code of New York St Nat ona2Ele tnc'Code,A%E New York State,the 2020 Fire Code of New York State,,the 2017 rovided in strict 7-16, and other relevant industry:standards;grid reg ds a pica le to s c suchfic-atinstallations. ' adherence to the governing regulations arid-standards -pp ; The mounting locations and methods detailed.in the sulimitted:Plans have undergone thorough osed scrutiny and are confirmed to align with the'requisite code s t UL9540A standards, ensuring it x BESS, utilizing Lithium Iron Phosphate technology„adhere the enclosure is meticulously designed to be does not exhibit thermal runaway. Fu_ithermore, - _ fire-resistant in accordance with;R327`of,the-NYS quildirig Code. al o inion, derived from the site inspection and detailed_ianalysis,`the�,proposed 1n my profession p m demonstrate"structural adequacy to�w BESS and the accompanying enclosure syste ithstand the reactions associated with the BESS. Please contact me if you have any questions or comments about the above. Sincere'Y\ OF NFW Je James 4koski, PE �P .5 DE., LO o -� 260 Deer Drive e..s; Mattituck, NY 11952. y' ' _ { w 631-774-7355 `. ,' ARQFESSto'.p�,.• • 1 SCOPE OF WORK --- r � - 'RGY.,.. • '-5I"N 4 DRA I BY' 1�7�. �J6i�s-�'' Q MEN' NE ,.. �'` 'c=''��`Y'•^ - '•S REVIEW 5Y J.M NA15CE'r CER`I`IE TO INSTALL A 40 KW BATTERY ENERGY 5TORAGE SYSTEM AT 5CHULTME15 RESIDENCE, • 051.12-129 LOCATED AT 13GO STERLING ROAD, CUTCHOGUE, NY 1 1935. TN15 BATTERY ENERGY 5TORAGE SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID =' THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 4 REV1510N5 1 DE5CRIPTION ------DATE REV k ORIGINAL -2/7/2024 SYSTEM RATING Southold a 1 a.: 40 kW AC STC <. EQUIPMENT SUMMARY _ .r Fep`nic _ mi 2 UNIT OF 50NNEN 50NNENCOPE+40KWH BATTERY ENERGY STORAGE J. CONTRACTOR S I-1 EET INDEX ELEMENT ENERGY, LLC. Pv-I COVER r;` 7470 SOUND AVE Pv-3 FLOOR PLAN iL ` MATTITUCK, NY 1 195 PV-4 ELECTRICAL DIAGRAM - PROJECT LOCATION LICENSE # G74G1-HI f LICENSE # 52G89-ME :GOVERNING CODES FEB - O�1 L 2017 NATIONAL ELECTRICAL CODE. F C U 2020 RESIDENTIAL CODE OF NEW YORK STATE. t 4 2020 BUILDING CODE OF NEW YORK STATE. ? 9 2020 FIRE CODE OF NEW YORK STATE. y A5CE 7-16 AND NFPA-70. UNDERWRITERS LABORATORIES(UL)STANDARDS �- 05HA 29 CFR 1910.2G9 ; x GENERAL NOTES _ '•`NAM` � 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT F ,z 0 w o U Q m THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE HIMSELF WITH THE INTENT OF THESE PLANS AMC) MAKE WORK AERIAL VIEW V�' `LI AGREE THE SAME. ) 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP � J z INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROMQ CONTRACTOR'S AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. LIABILITY, WORKMAN'S COMPENSATION, � 1V Lid COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES LLJ � 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND Lu U ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO p 1: 0 COMMENCING WITH WORK. ui JURISDICTION. N I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR O C)J I:4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS a- U U WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE O L THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS � U m THECONTRACTOR R. SHOULD HE FAIL O FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND U CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE; BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, SHEET NAME SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 5. ALL STRUCTURAL STEEL SHALL R LATE AND SHALL BE - F Nell/ COVER SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 J- CONSTRUCTION. !°fie , DEF O SPECIFICATIONS. � `� R 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE �Y °r G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE � �;� 0 DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. 4. CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING �3,' NYS CODES �REGULATIONS C� ;�•� of 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND m „s: w = CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. DRAWING SCALE CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS �O o� 5 2! 8 THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON .oR �� V�I .T.5. ;SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. O�SS N,P I I i'ROJECT FOR WHICH THEY ARE MADE I5 EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE SH=R NJM3ER 9. CONTRACTOR SHALL PROTECT, PATCH AMC) REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV— I RESULT OF HIS WORK. TAX MAP: 1000— 104.00-04.00-0 14.000 ---------------=XISTING PV SYSTEM _ -------------- :EIMBY =� LNG sY: (N)ENPHASE i NT ENERGY LLC COMBINER BOX MODEL I (E)100ARATED [PEVM.NABCEP CERTIFIE2-#12 AWG SKU 0-12-RAW-300.THWN NO#X2-IQ-AM1-24OA ESSENTIAL LOAD PANEL E,(13)108PLUS-72-2-US-- 1-#8 AWG.BARE COPPER GROUND I IPH 120R40V fiOHZ 1 I 1 2-1 2_ MICROINVERTERS � 'CELL IE)t00A/WIRE LESS I BRBRANCHA . DEM COMMS I IT FED) 13 HANWHA QCELLS'.0 PEAK REVISIONS DUO BLK ML-G10+405 I -- ---- - -"-'- I_10 GATEWAY /}\ (N)60A FUSED DE5CR1?TION DATE REV (12)IQ8PLUS-72-2-US—i-- 11(N /\ AC DISCONNECT I ORIGINAL 2/7/2024 MlcRowvERTERs -- SQUARE D D322NRB I aRANCH-t WITH BOA FUSES, I TO OTHER LOAD—/2 HANWHA QCELLS.Q.PEAK / DUO BLK ML-G10,405 , tM26A�. LOCKABLE,NEMA 3R, I (11)IOSPLUS-72-2-US- UL LISTED MICROINVERTERS i I BRANCH-1 11 HANWHA QCELLS:Q PEAK �b I ( 1 (N)2OOA AC (E)UTILITY METER DUO BLK ML-G10+405 - 6-912 AWG SKU:Q-12-RAW-300.THWN I I CONNECTIONS 1-#a AWG,BARE COPPER GROUND I 1 I MODULE I I 1 OI 3-912 AWG.THWN i i 3-#2AWG.THWN CONTRACTOR i 1-#8 E^uC,THWN 1-#B EGC,THWN , 1 I IN 3/4"PVC CONDUIT ; I IN 1-1/4'PVC CONDUIT 1 , 19 ELEMENT ENERGY, LLC. ------------------------=-------------- --------------------- 7470 SOUND AVE MATTITUCK, NY 1 195 LICENSE # G74G 1411 Tourl'TY I i LICENSE# 52G(59-ME UNDERGROUND 1 FEED �- (E 200A RATED 1 MAIN PH EPANEL(1) 0 0 IPH,t D240V 501Q I EXISTING WIRE RUK 12-MAIN ,�3. (EIGROUNDINGELECTROOE THROUGH CONDUIT BREAKER I _ 3-#3A)AWG,THWN I ' CONDUCTOR 066ARE CDPPER (TOP FED) 1-IA EGC,THWN IN 2"PVC CONDUIT ( I (N)100A MICRO GRID SUB PANEL I PROJ=C NAM__ o Lu o Lo i u_ v Q m w OO In LLJ Q 1� i } (n (D GEHERAL NOTES N)aoA/2P W Z z 1.)THE BE55 PROVIDES MONITORING AND BALANCING CELL 5-#8 AWG,THWN Q J SONNENCORE+ESS SONNENCORE+ESS 1-#8 EGc.THWN I (S-) IL/ LLJ VOLTAGES,CURRENTS,AND TEMPERATURES WITHIN THE IN CONDUIT 3-92 AWG,THWN SCORE-P20 SCORE-P20 LLJ MANUFACTURER5 SPECIFICATION THROUGH WEB AND MOBILE i-#B EGC,THWN Ln lLJ r(� 20kWh/240V 20kWh240V IN t-va•?vc CONDUIT r^ V APPLICATIONS. c c p O uj V J 2.)THE HEAT DETECTOR OR HEAT ALARM SHALL BE INSTALLED AND INTERCONNECTED WITH SMOKE ALARM AND THE BE55 SYSTEM I �' ff O 3 SHALL TRANSMIT AN ALARM SIGNAL VIA MOBILE PORTAL OR THE I -_ - 0 m U SMOKE AND/OR riEAT ALARM/DETECTOR IF POTENTIALLY ' HAZARDOUS TEMPERATURES OR OTHER CONDITIONS SUCH AScn — U SHORT CIRCUITS,OVER VOLTAGE OR UNDER VOLTAGE ARE i I DETECTED. 51-1EET NAME I I - - 3 LINE DIA. C 'OF NEIV (N)100A GRID SUB PANEL ,DE Y0 r� N ?..;tr'. �O DRAWING SCALE of N .T.S. \ NOTE: 1 w3Da/z?L Lu 1)CONDUITAND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS i u� AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5-910AWG THWN e �sl��; I �� SHE T NUMBER 1-#B EGO,THWN IN3/4"PVC CONDUIT 3-#6 AWG.THWN =1Y...y. 1-#3 EGC.THWN "-"��" P V—4 IN 1"PVC CONDUIT TAX MAP: 1000- 104.00-04.00-014.000 CONSTRUCTION NOTES CONSTRUCTION SUMMARY DESIGN-DRAIING BY: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE (2) UNIT OF SONNEN SONNENCORE+ 40KWH BATTERIES ELEMENT ENERGY LLC WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. (DIMENSIONS: 27.08"X G3.28"X 1 3.85") IN FIRE RATED REVIEW BY J.M.NABCEP CERTIFIE 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH ROOM 051 1 12-12? MINIMUM NEMA 3R RATING. 50NNEN 50NNENCORE+ 20KW DE55 UNITS REV_ IS_IO_N5 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. X5CRI?TiON DATE REv R L 4.)CONDUIT RUN/RACEWAY FOR BATTERY ENERGY OR 2%7/2024 STORAGE SYSTEM (BESS) SHALL BE LOCATED WITHIN PVC. ----- - -THE CONDUIT/WIRE RUNS TO THE EXISTING MAIN SERVICE - -- - -. . . - _...- PANEL AND TO THE PLP IN PVC CONDUIT SHALL BE LOCATED INDOORS. 5.)THE BESS 15 LOCATED IN THE EXISTING GARAGE. G.)THE BATTERY LOCATION FOR THIS PROJECT MUST ADHERE TO THE FIRE SAFETY STANDARDS OUTLINED IN ---THE NEW YORK STATE FIRE CODE(NY5 FIRE CODE R302). I ----IT 15 IMPERATIVE THAT THE EXISTING GARAGE BE INSPECTED AND APPROVED BY THE DE51GNATED FIRE DE ENFORCER TO ENSURE COMPLIANCE. PLEASE BE CONTRACTOR I ELEMENT ENERGY, LLC. ADVISED THAT WHILE WE ARE NOT CERTIFYING THE ELEMENT SOUND , LL ENCLOSURE OURSELVES, IT 15 UNDERSTOOD THAT IT MUST MEET THE AFOREMENTIONED FIRE CODE I MATTITUCK, NY 1 195 REGULATIONS. LICENSE # G74G I-HI LICENSE # 52G89-ME X15TING GARAGE DOOR PROJECT NAM= ILI° v Q m 01 Lli LLJ o � — (s) LLJ z z J 0 LLJ ILJ � J O 0 O U LEGEND o U m o EXISTING UTILITY METER IL — U MAIN SERVICE PANEL NEW PV SUB-PANELS A/C DISCONNECT COMBINER 5`IEE' 'NAME - -- -X15TING -UTI-L-ITY METER - INVERTERS- - __- GND ELECTRODE F N y PV MODULE PV LAYO U T 0 CRACKING RAIL p 'I ,{,!Y t CcP� o ATTACHMENT POINT ---RAFTERS rs iL -ROOF PITCH ANGLE DRAWING SCALE SUNRUN METER /4 11 _ I 1_O 1 50�' �Ci� VENT �(�[GARAGE PLAN FOR BESS AND FIRE RATED ENCLOSURE] AA?Q� O PLUMBING VENT� � ®SKY LIGHT `, Sy-[ET NUMBER ®CHIMNEY COMPOSITE SHINGLES PV-3 G00D CONDITION TAX MAP: 1000- 104.00-04.00-014.000 POTENTIAL SHADING ISSUES EITRIMREMOVE AS NECESSAR - zohv Sign Document ID: 1QuTzxYw5v4omTQms1znTa7u_oxsxxm Town ofSouthold Deoemberl/8th. 2024 ' Building ' Department � O �O%� --�� .lovvnHall Annex DEC~�` ^ ~ �~�` 54375 Main Road P.O. Box1178 Southold, New Ybrb11871-0S5S Subject: Batte[y Energy Storage System and Roof-Mounted PV System at Schultheis Residence. Located at 2400 Aldrich Ln. Laurel. NY 11948 Tb Town ofSouthold: I hereby affirm and certify that, following comprehensive professional evaluations, the plans for the installation of both the Solar PVSystem and the Battery Energy Storage System (BESG) comply with the 2020 Residential Code of New York State, the 2020 Building Code of New York State, the2O2O F|na Code of New York State, the 2017 National Electric Code, ASCE 7-16. and other relevant industry standards and regulations. These certifications are provided in strict adherence to the governing regulations and standards applicable to such installations. For the Solar PV System, it is my professional opinion that the subject plans comply with the aforementioned codes and standards. The structural framing of the existing roof has been evaluated to support the additional loads from solar panels, with deflection and stresses within allowable limits for wind pressures and snow loads specified in the codes. The mounting locations and methods indicated in the plans are deemed adequate, and the existing building and roof framing are structurally sufficient bo support the solar panels. Regarding the Battery Energy Storage System (BESS), the proposed plans have undergone thorough scrutiny and are confirmed to align with requisite codes and standards. Utilizing Lithium Iron Phosphate technology, the BESS adheres to UL9540A standards to prevent thermal runaway. The enclosure design meets fire-resistant requirements outlined in the N`/S Building Code. In my professional opinion, derived from site inspections and detailed ana|yaeo, both the proposed Solar PV System and the BESS, including the enclosure system, demonstrate structural adequacy towithstand associated reactions. Please feel free to contact me if you have any questions or require further clarification. Sincerely, or GannanoAnthony Givatno. P.E. CJ k'c~ GpeatEaotarn8on/icea. |no. PO Box 24O 24 Harvey Rd Riverhead, NY 11901 10344 K8obi|o: 831235.O18Q ` Zoho Sign Document ID:2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW SCOPE OF WORK - DE51GNG DRAFTING BY: ELEMENT ENERGY LLC TO INSTALL A 14.55 KWDC PV SYSTEM AND A 40 KW BATTERY ENERGY STORAGE 5Y5TEM AT 5CHULTHE15 RESIDENCE, Shette,Heights 05 1 1 1 2-1 29Island REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 13G0 STERLING ROAD, CUTCHOGUE, NY 11935. _ THE POWER GENERATED BY THE PV 5Y5TEM AND BATTERY ENERGY 5TORAGE SYSTEM WILL BE INTERCONNECTED WITH Shene,Island THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. S°gin°d REVISIONS SYSTEM RATING PQ Cn., DE5CRIPfI0N DATE REV REVISION 05-09-2024 g REVI510N 05-23-2024 C 40 kWh AC 5TC 14.58 KW DC 5TC REVI510N os-05-2024 v REV1510N 1 2-1 8-2024 E EQUIPMENT SUMMARY N° °e- G e.e 2 UNITS OF 50NNEN 50NNENCOPE+ 20 KW BATTERY ENERGY STORAGE ti°rack Say"'' 3G QCELL Q.PEAK DUO BLK ML-G 10+405 WATT PV MODULES eneaa°ck New Su o1k 39 ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS I IRONRIDGE XRI 00 MOUNTING SYSTEM La-re I I S E ET INDEX A I D ll E V I_l_ I CONTRACTOR PV-I COVER J—pon ELEMENT ENERGY, LLC. PV-2 51TE PLAN 7470 50UND AVE PV-3 PV PLAN " " es B dam°`°n MATTITUCK, NY 1 1952 PV-4 STRUCTURAL DETAILS PROJECT LOCATION LICENSE#G74G I-HI PV-5 BATTERY PLAN LICENSE# 52G89-ME PV-G ELECTRICAL DIAGRAM PV-7 LABELS GOVERNING CODES of NSIV O A G2 2017 NATIONAL ELECTRICAL CODE. < a • �P�?� O,P� 2020 RESIDENTIAL CODE OF NEW YORK STATE. t Y� 2020 BUILDING CODE OF NEW YORK STATE. 2020 FIRE CODE OF NEW YORK STATE. UNCp DERWRITERS LABORATORIES(UQ STANDARDS .. F OSHA 29 CFR 1910.29 G % �03443 !G Q�SSIONP\ GENERAL NOTES rC; PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT 0� THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE 0 w t11M5ELF WITH THE INTENT OF THESE PLANS AND MAKE WORK w z Q pmj AGREE THE SAME. AERIAL VIEW _ 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED U Q 0 — APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP z z INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, J AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. g In w 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 0 w w ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO 0 COMMENCING WITH WORK. O = JURISDICTION. 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR nO U m j 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE 0 N — U WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS O THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY t SHEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE FABRICATED AND INSTALLED AS PER LATEST A.1.5.0 CONSTRUCTION.STAIRS, ETC.. AS WELL AS PERMANENT COVE SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. 4 CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING DEC C Q NYS CODES*REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND C�24 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS uF�Aw"V 5CALL CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. N .T.5. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14 AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED - PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 5"eE'"UMBER EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV— I RESULT OF HI5 WORK. — ---- TAX MAP: 1000- 1 04.00-04,00-01 4.000 Zoho Sign Document ID.2A768FFA-2MLDY-91OIQJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW LEGEND / D DOSNNGGVPN 'N ELEMENT ENERGYJ LLC MAJIN IA PANEL O REVIEW BY N2BCCER TIFIER ONEW PV SUB-PANELS S 29 A/C DISCONNECT COMBINER E INVERTERS '-� GND ELECTRODE w270 Q REVISIONS PV MODULE �9 DE5CRIPTION DATE REV 2400 ®r, REV1510N 05-09-2024 —RACKING RAL 0 120° REV15ION 05-23-2024 C O ATTACHMENT POINT ?1p 1500 180- REVISION 06-05-2024 D ---RAFTERS REV151ON 12-18-2024 E F ROOF PITCH ANGLE eSUNRUN METER NEW PV AC DISCONNECT ®VENT EW BE55 UNITS IN THE GARAGE FIRST FLOOR O PLUMBING VENT EX15TING UTILITY MffE I5TING MAIN ELECTRICAL SERVICE PANEL IN BASEMENT ®SKY LIGHT ®CHIMNEY CONTRACTOR MOMPOSITE SHINGLES 8 ELEMENT ENERGY, LLC. OD CONDITION f :POTENTIAL SHADING ISSUES 7470® MATTI TO CON DIAVE TRIM/REMOVE AS NECESSARY LICENSE # G74G I-HI LICENSE # 52G89-ME ACCESS ROOF �P�pgo AEc ACCESS ROOF W ^ LLJ Zcn� 10 4 t� 'ORp�$S10NP�'� 18°FIRE SETBACK @RIDGE 16'FIRE SETBACK @RIDGE PROJECT NAME t� O LU Ln 0 O w z o Ln — 17-10" 20-I11 � z z N U w 0 w � 0 o N O w U m IL ( _ v t O 5t1EET NAME SITE PLAN ON5TRUCTION NOTES 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE DRAWING SCALE MANUFACTURER'S INSTALLATION INSTRUCTIONS. I /QII = I 1_01 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. v 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.)THE BATTERY ENCLOSURE SHALL BE COMPLIANT WITH 2O20 NY5 FIRE CODE THE BATTERY ENCLO5UREMU5T ADHERE TO THE FIRE SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE FIRE CODE(NY5 FIRE CODE R302). IT 15 IMPERATIVE THAT THE EXISTING GARAGE BE 5r1EET NUMBER INSPECTED AND APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO ENSURE COMPLIANCE. PV-IL PLEASE BE ADVISED THAT WHILE WE ARE NOT CERTIFYING THE ENCLOSURE OURSELVES, IT IS UNDERSTOOD THAT IT MUST MEET THE AFOREMENTIONED FIRE CODE REGULATIONS. TAX MAP: 1000- 04.00-04.00-0 14.000 Zoho Sign Document ID.2A768FFA-2MLDY-91010JITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW LEGEND EXISTING UMUTY METER N DE EI DRAFTING MENTENERGY LLBCY MAIN SERVICE PANEL 0° REVIEW BY J.M. NA13CEPP CERTIFIE NEW PV SUB-PANELS / A/C DISCONNECT COMBINER INVERTERS I^' u OND ELECTRODE V v270 Q REVISIONS PV MODULE 2ao° �,9°° DE5CRIFTION DATE REV E RACKING RAIL "x30 GROUND REV1510N 05-09-2024 B 21oo D 12°° REVISION 05-23-2024 C O ATTACHMENT POINT 180°150° REV1510N 06-05-2024 D ---RAFTERS S NEW PV AC DI NNECT REVISION 12-16202a E -*--ROOF PITCH ANGLE EW BE55 UNFT5 IN THE GARAGE FIR5T FLOOR �SUNRUN METER \\Mm ®VENT EXISTING UTII I5TING MAIN ELECTRICAL SERVICE PANEL IN BASEMENT OPLUMBING VENT ®SKY LIGHT ®CHIMNEY CONTRACTOR ®COMPOSITE SHINGLES ® ELEMENT ENERGY, LLC. GOOD CONDITION fPOTENTIAL SHADING ISSUES j MATT 0 50 NYDII AVE TRIM/REMOVE AS NECESSARY LICENSE#G74G I-HI Access RooF LICENSE# 52G59-ME OF Ew ACCESS ROOF �P yo�S- 2 18"FIRE 5E'fBACK aQRIDGE O �03443 18"FIRP SETBACK @RIDGE A�OSSIONP� PROJECT NAME W In 17'- 10" 20-1" 1-- w Q m o C� O a-/ DZ z r IV P NEL TYP. 0 = LU H U O m �U _ U TRINGICONNECTION TYP. 21 711 ARRAY#I ARRAY# 23 MODULES 13 MODULE5 SHEET NAME 22°PITCH 22°PITCH ICRO-INVERTER TYP CONSTRUCTION SUMMARY I G5°AZIMUTH I G5°A i IMUTH PV PLAN (3G)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULE5 (DIMENSIONS: 74"X 41.1"X 1.3") (3G)ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS (GO)ATTACHMENT POINTS @ G4"O.C. MAX. -erAWING SCALE (249.G)LP IRONRIDGE XRI 00 MOUNTING SYSTEM. ROOF TYPE: A5PHALT 511INGLE(SINGLE LA)ER) I /611 _ I 1_01 CONSTRUCTION NOTES 1.)ALL EQUIPMENT 5HALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S IN5TALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT 5HALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. SHEET NUMBER 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. PV-3 4.)WALL5 AND CEILING IN51DE THE BATTERY ENCL05URE 5HALL BE LMINATED WITH 5/8"TYPE X 5HEETROCK OR EQUIVALENT 5.)THE DOOR OF THE BATTERY ENCLOSURE SHALL BE 3G"WIDE MINIUMUM 20 MINUTE FIRE RATED DOOR. TAX MAP: 1 000-1 04.00-04.00-0 1 4.000 Zoho Sign Document ID 2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW L3AD CALCULATION ARRAY#I ARRAY#2 ITEM DESCRIPTION ARRAYS#1-2 DESIG:DRAFTING BY: RB Rid e BeamBoarci 2"X 10" D. FIRELEM ENERGY LLC R Rafter 2"X 8"D. FIR I G"O.C. REVIEW BY NAI3CEP CERTIFIE MODULE WEIGHT(Lbs) 48.4 48.4 (D) Deckm 5/8°PLYWOOD I 1 2-129 #OF MODULES 23 13 K Knee Walls 2"X G"D. FIR I G"O.C. TOTAL MODULE WEIGHT(Lbs) III 3.2 G29.2 J Ceilincl Joist 2"X 8"D. FIR I G"O.C. REVISIONS (P) Pitch 122° DE5CRF'nON DATE REV TOTAL LENGTH OF RAIL(Ft) 159.5 90.1 11) horizontal Span Of R 1 83" MAX. REV15ION 05-09-2024 B RAIL WEIGHT PER FOOT(Lbs) O.GB O.G8 REM510N 05-23-2024 C TOTAL RAIL WEIGHT(Lbs) 108.5 01.3 REV15ION OG-05-2024 D #OF 5TRANDOFF5 3G 24 (R) (RB) RFV1510N 12-18-2024 E WEIGHT PER 5TRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 72 48 TOTAL ARRAY WEIGHT(Lbs) 1293.7 735.5 POINT LOAD(Lb5) 35.9 30.8 CONTRACTOR TOTAL ARRAY AREA(5q Ft) 492.4 275.3 ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lbs/Sq Ft) 2.G 2.7 7470 SOUND AVE O MATTITUCK, NY 1 195 WIND DESIGN SUBJECT TO DAMAGE FROM LICENSE # G74G I-HI GROUND SEISMIC WINTER ICE BARRIER AIR MEAN SNOW DESIGN DESIGN UNDERLAYMENT FLOOD FREEZING ANNUAL LICENSE# 52G89-ME LOAD° Speed" Topographic Special Wmdborne CATEGORY Frost TEMP` REQUIRED" HAZARDS INDEM TEMP) (mph) effect5, wind region debn5 zone'" Weathering' depthb Termite` (K) 20 40 NO NO NO B SEVERE 3 FT HEAVY O A 5°F YES ZONE X 599 5 °F �P��OEC Y0, MANUAL J DE51GN CRITERIA" Indoor �h) s i LY Winter Summer design Heating temperature _ 4Wi Elevation Latitude Altitude correction factor Design temperature coohg m _ hearing cooling tempera difference J ture ( ) ="�" 105 FT 4 °N i 5°F 5G°F 1.00 70°F 75°F 55°F v10 �03443 P� �FESSION Wind Wind Coincident Winter Cooling temperature difference velocity velocity Daily range Summer humidity _ heating cooling wet bulb humidity PROJECT NAME ROOF FRAMING DETAIL III � 5'F 15 MPH 7.5 MPH 72`F MEDIUM(M) 4011. 32 GR @50%RH O For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. LU Ln W Z Q 00) a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth p strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. MODULE MOUNTING CLAMP (f) w U >_ b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction SOLAR MODULE g N w shall fill in the frost line depth column with the minimum depth of footing below finish grade. w C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. O w U d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined STAINLESS STEEL 3/8" _ BOLT AND NUT on a site-specific basis in accordance with Section R301.2.1.4. _J O e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York N = State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also O LU m U see Figure R301.2(1).] NRIDGE ALUMINUM RAIL n- f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New ALUMINUM"L"BRACKET n York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: ALUMINUM FLASHING I.The accompanying Flood Insurance Rate Map(FIRM), SHEET NAME ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. STRUCTURAL DETAILS h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ASPHALT SHINGLE ROOF effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5/1 G"x G"STAINLESS I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WITH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" 2 112"MIN THREAD j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method PENETRATION SEALED (Base 32°F)" WITH GEOCEL 4500 DRAWING SCALE k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the (EQUIVALENT OR BETTER) jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall indicate"NO"in this part of the table. ^ ) .T. . I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with I v "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the S EE7 NUMBER jurisdiction. 0. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at p` /_ elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. MOUNTING DETAIL r V 4 (`) See Figure R301.2(4)B. TAX MAP: 1000- 104.00-04.00-01 4.000 Zoho Sign Document ID:2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW CONSTRUCTION SUMMARY LEGEND DESIGN$DRAFTING 13Y: (2) UNITS OF SONNEN SONNENCORE+ 20 KWH BATTERY aExISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL REVIEW 13Y J.M.NABCEP CERTIFF. (DIMENSIONS: 27"X G9.5"X 14") IN ATTACHED GARAGE EN SONN04CDRE+2ORW BESS UNITS NEW PV SUB-PANELS 051 1 1 2-1 29 WITH REQUIRED FRONT CLEARANCE OF THIRTY-SIX INCHES r-3• s-S� 6 COMBNER DISCONNECT INVERTERS GND ELECTRODE REVISIONS CONSTRUCTION NOTES DE5cRIPnON DATE RE ®PV MODULE PEV15ION 05-09-2024 5 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE —RACKING RAIL .r - — REV15ION 05-23-2024 C WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. -�� ID• � o ATTACHMENT POINT 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH REVI510N 06-05-2024 D REVISION 12-I&2024 MINIMUM NEMA 3R RATING. �OF ---RAFTERS L 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE �� CEILING -*-ROOF PITCH ANGLE FIELD VERIFICATION. �SUNRUN METER 4.)CONDUIT RUN/RACEWAY FOR BATTERY ENERGY STORAGE SYSTEM (BESS)SHALL BE LOCATED WITHIN FIRE ®VENT RATED AREA. THE CONDUIT/WIRE RUNS TO THE EXISTING 2X4 +6•o.C,STUD w 0PLUMBING VENT MAIN SERVICE PANEL AND TO THE PUP IN PVC CONDUIT 1`— ®SKY LIGHT IN51DE OF THE EXISTING BASEMENT AND THEY SHALL BE CHIMNEY CONTRACTOR LOCATED INDOORS. m'w�7 ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. 5.)THI5 BE55 SYSTEM IS COMPLIANT WITH THE SECTION �` ®GOOD CONDITION 7470 SOUND AVE R327 OF THE INTERNATIONAL RESIDENTIAL CODE, AS POTENTIAL TRIM/REMOVE/REMOVE SHADING ISSUES MATTITUCK, NY 1 1 95 AMENDED BY THE NEW YORK STATE UNIFORM CODE. B. LICENSE#G74G I-HI THE BATTERY LOCATION MUST ADHERE TO THE FIRE SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE LICENSE# 52G89-ME FIRE CODE(NY5 FIRE CODE R302). IT IS IMPERATIVE THAT THE AREA WHERE BESS 15 LOCATED BE INSPECTED AND APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO OF NEly y ENSURE COMPLIANCE. PLEASE BE ADVISED THAT WHILE O A Gi 0 WE ARE NOT CERTIFYING THE ENCLOSURE OURSELVES, IT 15 UNDERSTOOD THAT IT MUST MEET THE AFOREMENTIONED FIRE CODE REGULATIONS. J n W 2r-3• 103443 v Q�sSl( -11• PROJECT NAME O LLJ In 2 U m N O m \11ST:NG GARAGE WALL o U.J z C� Z Z W O w LLJ w It In N O U O U m O N U D- R 5HEET NAME BATTERY PLAN DRAWING SCALE 1 /4/I II _ I 1-01 [GARAGE PLAN] SHEET NUM13EP. PV-5 TAX MAP: 1 000- 104.00-04.00-01 4.000 Zoho Sign Document ID:2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW (N)ENPHASE COMBINER BOX MODEL DE51GN 4 DRAFTING BY: 2-#12 AWG SKU.Q-02-RAW-30Q THWN NO#X2-IQ-AM1-240-4 0d)10DA RATED ELEMENT ENERGY LLC (10)IQ8PLUS-72-2-US 1-#8 AWG,BARE COPPER GROUND ESBEI AL LOAD PANEL MICROINVERTERS +PN'lzwz4DV. REVIEW BY J.M.NABCEP CERTIFIE CELL WIRELESS 3-#B AWG,THWN-2 (N)WA 12P MAIN 051 1 12-129 BRANCH-1 MODEM COMMS 1-#8 EGC,THWN-2 BREAKER TOP FED) 10 HANWHA OCELLS Q PEAK N IN 3/4"PVC CONDUIT DUO BLK ML-G10+405 IQ GATEWAY (N)60A FUSED REVISIONS (10i IQ8PLUS-72-2-US N) AC DISCONNECT DE5CR PTION DATE REV MICROINVERTERS m SQUARE D D322NRB 1 REVISION 05-09-2024 B WITH 50A FUSES, To orNeP LOAD BRANCH 1 N)2Dn� KNIFEBLADE, m REVI510N 05-23-2024 C 10 HANWHA QCELLSOPEAK r\ DUO BLK ML-G10+405 LOCKABLE,NEMA 3R, 44(10)IQ8PLUS-72-2-US UL LISTED in Rev151oN o6-os-zoza D MICROINVERTERS �b rN,� REVISION 1 2-1 82 024 E BRANCH-11- (E) UTILITY METER 10HANWHAQCELLS:Q.PEAK N �b (N)204 (N)200A PATH-THROUGH DUO SILK ML-G10t 405 AC CONNECTIONS MODULE 6-#12 AWG SKU:0-12-RAW-300,THWN 3-#2 AWG,THWN-2 1-#8 AWG,BARE COPPER GROUND 1-08 EGC,THWN-2 IN 1-1/4"PVC CONDUIT .g• CONTRACTOR (E)200A RATED ELEMENT ENERGY, LLC. MAIN SERVICE PANEL(1) 1 PH.120I2GOV 60HZ 7470 SOUND AVE 6-#6 AWG,THWN-2 MA-MTUCK, NY 1 195 1-;Y8 EGO THWN-2 TO UTILITY LICENSE# G74G I-HI UNDERGROUND FEED LICENSE# 52G(59-ME EXISTING WIRE RUN (E1211DA BREAKER �ti QF NE;v y NDUCTOR NG ELECTRODE THROUGH CONDUIT (STOP FED Q_ �¢0 A �� CONDUCTOR>ffi BARE COPPER U'' m ' w Zs _ z GENERAL NOTES �O 7C3443� ��C9 IN)210A/2P BREAKER- 1.)THE BE55 PROVIDES MONITORING AND BALANCING CELL RO�SSIONP� VOLTAGES,CURRENTS, AND TEMPERATURE5 WITHIN THE MANUFACTURER'5 SPECIFICATION (N)100A MICRO THROUGH WEB AND MOBILE APPLICATIONS. TIHWN GRID SUB PANEL PROJECT NAME 2.)THE HEAT DETECTOR OR HEAT ALARM 5HALL BE IN5TALLED AND 1-#6A EGC,'THWN INTERCONNECTED WITH 5MOKE ALARM AND THE BE555Y5TEM IN1-12"PVC CONDUIT 0 U- SHALL TRANSMIT AN ALARM 51GNAL VIA MOBILE PORTAL OR THE w L7) SMOKE AND/OR HEAT ALARM/DETECTOR IF POTENTIALLY 2 U � m HAZARDOUS TEMPERATURES OR OTHER CONDITIONS SUCH A5 M40A/zP LU Q QO SHORT CIRCUITS,OVER VOLTAGE OR UNDER VOLTAGE ARE 0 3.)TCONDUIT AND CONDUCTORS SPECIFICATIONS ARE 5A5ED ON NI40A/2P � Z Z MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT 5-#8 AWG,THWN _j �T UP-51ZING A5 REQUIRED BY FIELD CONDITIONS. SONNENCORE+ESS SONNENCORE+ESS 1-#8EGC,THWN g L IN r Pvc CONDUIT SCORE-P20 SCORE-P20 3-#2AWG,THWN W LU ELECTRICALNOTE5 20kWh/240V 2okVVtn40V 1-#8 EGC,THWN c - IN 1-1/4"PVC CONDUIT Q O 1.)ALL EQUIPMENT TO BE L5TED BY UL OR OTHER NRTL,AND LABELED FOR IT5 O v O APPLICATION. U c9 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. v O N U 3.)WIRING,CONDUIT,AND RACEWAY5 MOUNTED ON ROOFTOPS SHALL BE ROUTED 0 DIRECTLY TO,AND LOCATED A5 CL05E A5 POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. 4.)WORKING CLEARANCES AROUND ALL NEW AND EX15TING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 1 10.2G. SHEET NAME 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550RIE5 TO FULFILL APPLICABLE CODES AND STANDARDS. LINE D I A. G.)WHERE SIZES OF JUNCTION BOXE5, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, _ _ THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.)MODULE GROUNDING CUP5 TO BE IN5TALLED BETWEEN MODULE FRAME AND MODULE SONNEN SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. (N)100A GRID Sue PANEL 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG DRAWING 5CALE OR ILSCO GBL-4DI3T LAY-IN LUG. OR THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5bve/negative) NI40A/zP ^ I T I + 10.)THE DC SIDE OF THE PV 5Y5TEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC I v I G90.35. 1 1.)THE INSTALLATION COMPUE5 WITH R327 ENERGY 5TORAGE 5Y5TEM5. 12.)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BA5ED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING A5 REQUIRED BY FIELD s-IEET NUMBER CON DITION5. 5-#10 AWG,THWN 1-#B EGC,THWN I �/D\ /_C ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8'ABOVE ROOF IN3/4"PVCCONDUIT 3-#2 AWG,THWN WITH PROPER JUNCTION BOX AT EACH END. 1-#8 EGC,THWN IN 1"PVC CONDUIT TAX MAP: 1000-104.00-04.00-014.000 Zoho Sign Document ID:2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW SERVICE METER O O DESIGN i DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGYLLC SOLAR PV SYSTEM PHOTOVOLTAIC $ ' • ( I ) ALL LABEL SMALL BE INSTALLED IN REVIEW BY J.M.NABCEPCERTIFIE . OS I 112-1 29 EQUIPPED WITH SOLAR BREAKER DC DISCONNECti ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® •• O C REQUIREMENTS. RevlsloNs DESCRIPTION DATE REV OPERATING CURRENT A (2) ALL LOCATIONS ARE APPROXIMATE AND REV1510N Os-09-2024 B VOLTAGE MAX SYSITEM � REVISION 05-23-2024 C SOLAR AC LOAD CENTER- OUTSIDE �DOWTFaMATETM O. CURRENT REQUIRE FIELD VERIFICATION. REVI510N os_05_2024 D ` (3) LABELS, WARNING(S) AND MARKING REVISION 12-18-2024 E �„�SW „� 0 SMALL BE IN ACCORDANCE WITH NEC THE VW "�=T0 1 10.21 (5). j PV SYSTEIII AND REl UCE , - - -- CAUTM -SH0C1C HRZARON TlEARRAY - -__ AC DISCONNECTF�IWOUIO�SOUP= (4) THE MATERIAL USED FOR MARKING gymUmAns °°"°"" MUST BE WEATHER RESISTANT, IN COMPLIANCE WITH NEC 1 10.2 1 (5)(3).SOLAR AC LOAD CENTER- INSIDE ® �� �� CONTRACTOR ® O ® I I �Y � ,;� (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY,AVE� ± Pam. 7470 SOUND E >I 1 , , NG SMALL BE LABELED INSTALLED IN IMATTITUCK, NY 1195 SOUPMTDaR�OFAil "DUAL OWER LY COMPLIANCE WITM NEC G90.3 1 . LICENSE # G74G 1-HI OVERC ROWBEVICES.EXClllDM SOURCES:UTRITYGR� LICENSE# 52G89-ME IIN SUPP LY AND PV SOLAR DEVICE.SIYILL NOT E1ICEED 1 ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING NfMIf71rOFNAMR --- O pF NEtq.y ---------------------------------- -- THIS SERVICE (� � � _ __ LU ELECTRIC SHOCK WIZARD PHOTOVOLTA7EYST w TER11W1LS ON THE LINE AND I COMBN6 PHOTOVOLTAIC SYSTEMLORD SM MAY BE E NERG�D DO NOT AD 103443 CONDUIT - OUTSIDE BUILDING -"N THE OPMPOSIMON SSIONP�, ` . . • , PROJECT NAME •* if 0 O w w FIFLAALWER SUPP Ln LY w z C) ISOURCES:UTILITYGRD AND z O — PV SOLAR EI Lcpac SYSiE11' _ MAIN SERVICE PANEL - OUTSIDE j N O A CAUTION SOLAR CIRCUIT U z z ACAUTlON _ N 0 SMAR UK-RC SYSTEM CCAI*hCTED p _ LJ MAIN SERVICE PANEL - INSIDE . OPERATING OPERATING VOLTAGE VOLTS POVNHiSOURCE } OUTPUT CONNECTION ® O DO NOT RELOCATE THIS SHEET NAME OVERCURRENT DEVICE SIGNAGE AC DISCONNECT/BREAKER DRAWING SCALE 00 N .T.S. SHEET NUMBER PV-7 TAX MAP: 1 000- 1 04.00-04.00-0 1 4.000 Zoho Sign Document ID:2A768FFA-G1A9GMC_LEI7YQRIBR9QPWVZTLPKLLNOC6UQ.,Y14R- W I,r, Town of Southold r II 1st, 2024 Building Department : Town Hall Annex i } 54375 Main Road �t .4 MAY 1 0 2024 : P.O. Box 1179 Southold, New York 11971-0959 ..r�,a�,,,,.= Subject: Battery Energy Storage System and Roof-Mounted PV System at Schultheis Residence Located at 1360 Sterling Rd Cutcho ue NY 11935AMENDMENT To Town of Southold: 5-;LeL 1 hereby affirm and certify that, following comprehensive professional evaluations, the plans for the installation of both the Solar PV System and the Battery Energy Storage System (BESS) comply with the 2020 Residential Code of New York State, the 2020 Building Code of New York State, the 2020 Fire Code of New York State, the 2017 National Electric Code, ASCE 7-16, and other relevant industry standards and regulations. These certifications are provided in strict adherence to the governing regulations and standards applicable to such installations. For the Solar PV System, it is my professional opinion that the subject plans comply with the aforementioned codes and standards. The structural framing of the existing roof has been evaluated to support the additional loads from solar panels, with deflection and stresses within allowable limits for wind pressures and snow loads specified in the codes. The mounting locations and methods indicated in the plans are deemed adequate, and the existing building and roof framing are structurally sufficient to support the solar panels. Regarding the Battery Energy Storage System (BESS), the proposed plans have undergone thorough scrutiny and are confirmed to align with requisite codes and standards. Utilizing Lithium Iron Phosphate technology, the BESS adheres to UL9540A standards to prevent thermal runaway. The enclosure design meets fire-resistant requirements outlined in the NYS Building Code. In my professional opinion, derived from site inspections and detailed analyses, both the proposed Solar PV System and the BESS, including the enclosure system, demonstrate structural adequacy to withstand associated reactions. Please feel free to contact me if you have any questions or require further clarification. Sincerely, <OF NEW Y Gennaro Anthony Giustra. P.E. _ Great Eastern Services, Inc. * �' PO Box 240 2 24 Harvey Rd Riverhead, NY 11901 A'�oFEss1oNP� Mobile: 631.235.0189 Email: jerrygiustra@gmail.com Zoho Sign Document ID:2A768FFA-G1A9GMC_LE17YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C SCOPE OF WORK DESIGN t DRAFTING BY: ELEMENT ENERGY LLC Sheltertsland x REVIEW BY J.M.NABCEP CERTIFIE TO INSTALL A 14.58 KWDC PV SYSTEM AND A 40 KW BATTERY ENERGY STORAGE SYSTEM AT 5CHULTHE15 RESIDENCE, i LOCATED AT 13GO STERLING ROAD, CUTCHOGUE, NY 1 1935. 051 1 1 2-1 29 THE POWER GENERATED BY THE PV SYSTEM AND BATTERY ENERGY STORAGE SYSTEM WILL BE INTERCONNECTED WITH x Sheffer taland E _ THE UTILITY GRID THROUGH THE „ Southold,EXISTING ELECTRICAL SERVICE EQUIPMENT. , a £ a b� �� A 1 .4 REVISIONS SYSTEM RATING Fero�: y , s ' 2 `oa J, // ••^�• } M ...,;idSF �t DE5CRIPiION DATE REV ra + r, s"" REVISION 05-09-2024 9 40 kW AC 5TC ... 14.58 KW DC 5TC EQUIPMENT SUMMARY Cut hogue�r� North Haven any P41NT 2 UNITS OF 50NNEN 50NNENCOP 20 KW BATTERY ENERGY STORAGE % Mai.. Sa9Habor " 36 QCELL Q.PEAK DUO ELK ML-G 1 0+ 405 WATT PV MODULES MattttuoR- Hawsurrolk ' . 36 ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS /" �'" 's I I IRONRIDGE XRI00 MOUNTING SYSTEM SHEET INDEX 1� CONTRACTOR si Pv-I covER � P25 - • ' � L ELEMENT ENERGY, LLG. James ort• 7470 SOUND AVE MATTITUCK, NY 1 1952 PV-2 51TE PLAN Sourx `�`Q� tirBtdgehampta PV-3 PV PLAN PV-4 STRUCTURAL DETAILS PROJECT LOCATION LICENSE# G74G I-HI PV-5 BATTERY PLAN LICENSE# 52G89-ME PV-6 ELECTRICAL DIAGRAM PV-7 LABELS NE GOVERNING CODES P�� F pF wo 2017 NATIONAL ELECTRICAL CODE. AMENDMENT A o�_�� C 2020 RESIDENTIAL CODE OF NEW YORK STATE. 2020 BUILDING CODE OF NEW YORK STATE. d e 2020 FIRE CODE OF NEW YORK STATE. t >� m 2 A5CE 7-1 6 AND NFPA-70. UNDERWRITERS LABORATORIES (UL)STANDARDS �p �103445 05HA 29 CFR 1910.269 ARO�ssloNP GENERAL NOTES APPROVED AS NO ED PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT • SS/a'A 2 THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE DA B.P. 0 J w HIMSELTHEF INTENT OF THESE PLANS AND MAKE WORK FEE BY AERIAL VIEW w z Q n 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED NOTIFY BUILDINGDE } o o — ASPECTI LS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWR319 ` 9?LffWIT94A9 BDWP9KOVAL STAMP z Ln z INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, g N AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. LU COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES w 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND ( �. FOUNDATION-TWO REQUIRED � o ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO FOR POURED CONCRETE o J COMMENCING WITH WORK. w JURISDICTION. 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR Z. ROUGH-FRAMING&PLUMBING n _ 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS 0 U — MAINTAINING SAFETY ON THE JOB SITE DURING THE 3. INSULATION EL to U WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS � THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFELY AND 4. FINAL-CONSTRUCTION MUST ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THI5 SHALL INCLUDE, BUT ARE NOT BE COMPLETE FOR C.O. CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, ALL CONSTRUCTION SHALL MEET THE RESPONSIBILITY AND LIABILITY THEREFROM 51EET NAME SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 5. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE REQUIREMENTS OFTHE CODES OF NEW SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT COVE FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 YORK STATE. NOT RESPONSIBLE FOR (� p SPECIFICATIONS. CONSTRUCTION. - - - 1 l� L 11 G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE DESIGN ORCONSTRUCTON ERRORS U UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING ff NYS CODES 4-REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING e ,� Q CONDITIONS PRIOR TO ORDERING MATERIALS AND V G�/ IO'I� t 1 0 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN I t SAY 1 2024 COMMENCING WITH WORK. � t I>a DRAWING SCALE CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON �,Q r�. 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. �`"' ``: ' " •T T.v SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED t -,• ` PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THI5 PROJECT TOTAL SATISFACTION OF THE OWNER PRIDR TO RELEASE OF SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV— RESULT OF HIS WORK. TAX MAP: 1 000- 104.00-04.00-01 4.000 i ..e r Zoho Sign Document ID:2A768FFA-G1A9GMC LE17YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C LEGEND ^/ DESIGN 3 DRAFTING BY: o EXISTING REVIEW BY VICE PANEL D°UTILITY METER •• ELEMENT ENERGY LLC MAIN SER J.M.NABCEP CERTIFIE --�,i NEW PV SUB-PANES 051 1 1 2-1 29I A/C DISCONNECT COMBINER INVERTERS n GND ELECTRODE V v270 Q REVISIONS DFSCRIPTION DATE REV PV MODULE 240° 90°E REV1510N 05-09-2024 B RACKING RAIL ®r7 120° 0 O ATTACHMENT POINT '0 lsoo �8Q° 36" 36"G OUND ACCE S iYP. ---RAPIERS PROOF PITCH ANGLE S �SUNRUN METER NEW PV AC DISCONNECT ®VENT EW BE55 UNITS IN THE GARAGE FIR5T FLOOR D PLUMBING VENT EXISTING UTILITY METER / I5TING MAIN ELECTRICAL SERVICE PANEL IN BASEMENT r ®SKY LIGHT / CONTRACTOR ® COMPOSITE SHINGLES CHIMNEY / ELEMENT ENERGY, LLC. GOOD POTEN�SHADING ISSUES / / 7470 SOUND AVE DTRIM/REMOVE AS NECESSARY / / / / ® / ; / /% MATTITUCK, NY 1 1952 LICENSE# G74G I-HI LICENSE# 52G89-ME r 111 8"FlRESETBACK@RDGE/�/ / �f/ /// %/, ,////. /, PROJECT NAME I � O LL. LLJ LLl U-1 Z Q O O 20'- 1 II 1 7' 1 0" z z O � = w QD LLJ p :D O U 1 O U m IL Ln U O SNEET NAME ---------- - - - - -- SITE PLAN - ON5TRUCTION NOTES DRAWING SCALE I.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. I /QII = I 1_01 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3P,RATING. CVJ 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.)THE BATTERY ENCLOSURE SHALL BE COMPLIANT WITH 2O20 NY5 FIRE CODE THE BATTERY ENCL05URIfMU5T ADHERE TO THE FIRE SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE FIRE CODE(NY5 FIRE CODE R302). IT 15 IMPERATIVE THAT THE EXISTING GARAGE BE 5NEET NUMBER INSPECTED AND APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO ENSURE COMPLIANCE. PV-2 PLEASE BE ADVISED THAT WHILE WE ARE NOT CERTIFYING THE ENCLOSURE OURSELVES, IT 15 UNDERSTOOD THAT IT MUST MEET THE AFOREMENTIONED FIRE CODE REGULATIONS. TAX MAP: 1 000-1 04.00-04.00-0 1 4.000 Zoho Sign Document ID:2A768FFA-G1A9GMC LEI7YQRIBR9QPVWZTLPKLLNOC6UQ9YN4R-C LEGEND DESIGN doDRAFTING BY: EKISTING UTILITY METER '•�/ ELEMENT ENERGY LLC ®MAIN SERVICE PANEL 0o REVIEW BY J.M., N 5GEP CERTIFIE 051 29 NEW PV SUB—PANELS I A/C DISCONNECT COMBINER INVERTERS /1�27p o ® GND ELECTRODE V'/ Q DE5CRIPTONVI510 DATE REV PV MODULE 24p° ®r, �9O°E —RACKING RAIL 210 R visioN os 120° 36°x 39"GROUND ACCESS TYP. a9-2oz4 B o ATTACHMENT POINT 1 8 °15p° ---RAFTERS S NEW PV AG DISCONNECT -*--ROOF PITCH ANGLE EW BE55 UNITS IN THE GARAGE FIRST FLOOR eSUNRUN METER ®VENTfY15TING UTILITY METER ISTING MAIN ELECTRICAL SERVICE PANEL IN BASEMENT PLUMBING VENT OEM ® SKY LIGHT ®/ CONTRACTOR ®CHIMNEY ELEMENT ENERGY, LLC. COMPOSITE SHINGLES ®GOOD CONDITION MEN— ; / / 7470 SOUND AVE iM/REuov!E % / / /� , i MATTITUCK, NY 1 195/, / / / / / / / LICENSE# G74G I-HI LICENSE/ % / / j / / # 52G89-ME /, OF NE ='ss eooFCO ENEx, / / / 1 8"FIRE SETBACK ROFESs1ONP PROJECT NAME u o cm 201- 1 " LU w Q m o 0 I7-IO" - w z z 2 V PAI•!EL TYP. O w LU I— C� N f LU j OL O i U m LU O U _ U 2'-7"-- o TRING/CONNECTION TYP. ARRAY#I ARRAY# 23 MODULES 13 MODULES SHEET NAME ICRO-INVERTER TYP. 22' PITCH 22' PITCH CONSTRUCTION SUMMARY I G5°AZIMUTH I G5°AZIMUTH PV PLAN (3G) QCELL Q.PEAK DUO BLK ML-G 1 0+ 405 WATT PV MODULES (DIMENSIONS: 74"X 4 1.1"X 1.3") (3G) ENPHA5E I08PLU5-72-2-1,15 MICRO INVERTERS (GO)ATTACHMENT POINTS @ G4"O.C. MAX. DRAWING SCALE (249.G) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. fQ� ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) I /vII — I I_OI CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SHEET NUMBER 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 2 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. PV_3 4.)WALLS AND CEILING IN51DE THE BATTERY ENCLOSURE SHALL BE LMINATED WITH 5/8"TYPE X 5HEETROCK OR EQUIVALENT 5.)THE DOOR OF THE BATTERY ENCLOSURE SHALL BE 3G"WIDE MINIUMUM 20 MINUTE FIRE RATED DOOR. TAX MAP: 1 000-1 04.00-04.00-0 1 4.000 _L Zoho Sign Document ID:2A768FFA-G1A9GMC_LEI7YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C LOAD CALCULATION ARRAY#I ARRAY#2 ITEM DE5CRIPTION ARRAYS #1-2 DE51GN$DRAFTING BY: RB Ricicie Beam/Board 2"X 10" D. FIR ELEMENT ENERGY LLC R Rafter 2"X 8"D. FIR I G"O.C. REVIEW BY J.M.NABCEP CERTIFIE MODULE WEIGHT(Lb5) 45.4 45.4 (D) Decwn 5/6"PLYWOOD 051 1 1 2-1 29 #OF MODULES 23 13 (K) Knee Wa115 2"X G°D. FIR I G"O.C. TOTAL MODULE WEIGHT(Lb5) 1 1 13.2 G29.2 U Cohn J015t 2"X 8"D. FIR I G"O.C. REVISIONS (P Pitch 22° DE5CRIPTION DATE REV TOTAL LENGTH OF RAIL(Ft) 159.5 90.I h) Horizontal 5 an of(R) 1,53"MAX. Rew510N 05-0e-2024 5 RAIL WEIGHT PER FOOT(Lb5) 0.G8 O.G6 TOTAL RAIL WEIGHT(Lbs) 108.5 G 1.3 #OF 5TRANDOFF5 3G 24 WEIGHT PER 5TRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT 05) 72 48 TOTAL ARRAY WEIGHT 05) 293.7 735.5 POINT LOAD(Lb5) 35.9 30.5 CONTRACTOR TOTAL ARRAY AREA(5ci Ft) 402.4 275.3 ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lbs/5q Ft) 2.G 2.7 7470 SOUND AVE � ) MATTITUCK, NY 1 1952 GROUND WIND DESIGN SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE BARRIER FLOOD AIR MEAN LICENSE# G74G I-HI LICENSE# 52G89-ME SNOW DESIGN DESIGN UNDERLAYMEIJT FREEZING ANNUAL LOAD° Spec Topographic Special Windborne GATEGORYr Frost TEMP` REQUIRED" HAZARDS9 INDEXi TEMP k i Weathering' line Termite` �'y �F NE(� (mph) effects wend region debris zone'" depthb MOD TO FEMA �(� 20 40 NO NO NO B SEVERE 3 FT HEAVY 5°F YES ZONE X 599 5 °F �Q O A G�GsO�f MANUAL J DESIGN CRITERIA" Indoor ( ) n W Elevation Latitude Wintery Summer Altitude correction factor de5iign Design temperature cooling Heating temperature (J) 2� heatin coolin tempera difference p 103443 105 FT 41°N 1 5°F 8G°F 1.00 70°F 75°F 55°F AR�FESSION�� Wind Win Coincident Winter Cooling temperature difference velocity velocity ,Net bulb Daily range humidity Summer humidity - PROJECT NAME heating cooling I ROOF FRAMING DETAIL � 151 F 15 MPH 7.5 MPH 72°F MEDIUM(M) 407. 32 GR @50%PH O ILJ L() For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. w z Q co I-_ w p — a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth C� oL — strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,"moderate"or"severe"for concrete as MODULE MOUNTING CLAMP w U Z determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. D_/ D_/ Z b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction SOLAR MODULE :51 d) B2 u.J shall fill in the frost line depth column with the minimum depth of footing below finish grade. O w LLJ C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. 5TAINLE55 STEEL 3/5" N O d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined BOLT AND NUT Q O = on a site-specific basis in accordance with Section R301.2.1.4. w D U U e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York = crl State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also O0 Ln U see Figure R301.2(1).] NRIDGE ALUMINUM RAIL O If. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. D_ g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New ALUMINUM"L"BRACKET York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: ALUMINUM FLASHING SHEET NAME i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. — --- STRUCTURAL DETAILS - h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ASPHALT SHINGLE ROOF effects of ice damming,the jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5110 x G"5TAINLE55 I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WITH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." 2 1/2"MIN THREAD j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method PENETRATION SEALED (Base 32°F)." WITH GEOCEL 4500 DRAWING SCALE k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the (EQUIVALENT OR BETTER) jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall indicate"NO"in this part of the table. N .T.S. I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the SHEET NUMBER jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at P V_4 elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. MOUNTING DETAIL (') See Figure R301.2(4)B. TAX MAP: 1000-104.00-04.00-0 14.000 _e Zoho Sign Document ID:2A768FFA-G1A9GMC_LEI7YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C CONSTRUCTION SUMMARY LEGEND DE51GN s DRAFTING BY: EXS- (2) UNITS OF SONNEN SONNENCORE+ 20 KWH BATTERY EMAIN ISE UTILITY METER PANEL REVIEW BY J.M.NABCEP CERTIFIE (DIMENSIONS: 27"X G9.5"X 14") IN ATTACHED GARAGE -- r-�'_----- ,w-s• — - - NEW PV SUB—PANELS 051112-129 WITH REQUIRED FRONT CLEARANCE OF THIRTY-SIX INCHES COOMBIINENECT INVERTERS e REVISIONS GND ELECTRODE DESCRIPTION DATE REV CONSTRUCTION NOTES Pv MODULE REVISION 05-09-2024 B 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE —RACKING RAIL WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. -' ' - UT5IDE °�y "`. o ATTACHMENT POINT 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH t ---RAFTERS MINIMUM NEMA 3R RATING. ��� 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE -ROOF PITCH ANGLE FIELD VERIFICATION. muFwr,GU IT ���� r; �SUNRUN METER 4.)CONDUIT RUN/RACEWAY FOR BATTERY ENERGY 1 \ ®VENT STORAGE SYSTEM (BESS)SHALL BE LOCATED WITHIN FIRE t OPLUMBING VENT RATED AREA. THE CONDUIT/WIRE RUNS TO THE EXISTING MAIN SERVICE PANEL AND TO THE PLP IN PVC CONDUIT SKY LIGHT O.111 ARE ITED 5EL DODR 1 ® CONTRACTOR IE INSIDE OP THE EXISTING BASEMENT AND THEY SHALL BE CHIMNEY LOCATED INDOORS. j COMPOSITE SHINGLES ELEMENT ENERGY, LLC. 5.)THIS BESS SYSTEM IS COMPLIANT WITH THE SECTION ®GOOD CONDITION 7470 SOUND AVE POTENTIAL SHADING ISSUES R327 OF THE INTERNATIONAL RESIDENTIAL CODE, AS �TRIM/REMOVE AS NECESSAR MATTITUCK, NY 1195 AMENDED BY THE NEW YORK STATE UNIFORM CODE. \,s..... sie•FlRE.%GW. G.)THE BATTERY LOCATION MUST ADHERE TO THE FIRE j eoA�ou WALLS SEPABOTH 51D RATUII A-MGGsoE LICENSE # 6746 I-I 11 GARAGE LICENSE# 52G89-ME SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE P,OMTHE DWELULIG UNIT FIRE CODE(NYS FIRE CODE R302). IT IS IMPERATIVE THAT j THE AREA WHERE BESS IS LOCATED BE INSPECTED AND ! OF NE!/y APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO �� Yp I IRE RATE?ATiI.^,4C,;,55 n l ENSURE COMPLIANCE. PLEASE BE ADVISED THAT WHILE Accowwl wlrnRsozF �pR G/(�s �� WE ARE NOT CERTIFYING THE ENCLOSURE OURSELVES, IT 15 UNDERSTOOD THAT IT MUST MEET THE �� �e _ AFOREMENTIONED FIRE CODE REGULATIONS. 2 O 703443 AR�FEsstoNP� +'.,. PROJECT NAME CIL 30ARD OU 4'_E%PpSED zr-t7• " ''� I O IL w Ln fr w Z O00 QD LLJ Z Z I F� f w it ^`tl allreu samEPCOPZE z0KW 9Ess BINS O = (� Q) O U "> ' r O to — U s y: SHEET NAME R t - - — — - -- - BATTERY PLAN ---- p. DRAWING SCALE 1211 _ I 1-01 [GARAGE PLAN] SHEET NUMBER FV-5 TAX MAP: 1 000-104.00-04.00-01 4.000 Zoho Sign Document ID:2A768FFA-G1A9GMC_LEI7YQRIBR9QPVWZTLPKLLNOC6UQ9YN4R-C (N)ENPHASE DESIGN 6 DRAFTING BY: COMBINER BOX MODEL 2-#12AWGSKU'.0-12-RAW-300,THWN NO#X2-IQ-AM1-240-4 ESSENTIAL)LODADPAE� ELEMENT ENERGYLLG (10)IQ8PLUS-72-2-US, 1-#8 AWG.BARE COPPER GROUND 1PH.12D240V WH2 MICROINVERTERS REVIEW BY J.M.NABCEP C R I I I CELL WIRELESS (N)60A/2PMAIN 051112-129 MODEM BREAKER BRANCH-1 COMMS (TOP FED) _-. 10HANWHAOCELLS O PEAK NV DUO BLK ML-G10+405 r 10 GATEWAY II (N)60A FUSED REVISIONS (10)IQ8PLUS-72-2-US N)1, �. AC DISCONNECT DescwPTloN DATE RFv MICROINVER7ERS I SQUARE D D322NRB • REV151ON 05-09-2024 B BRANCH-1 N)20A WITH 5D A FUSES, To OTHER LOAD 10 HANWHA QC ELLS Q PEAK KN I FEBLADE, DUO BLK ML-G10+405 Nv N)zoA� LOCKABLE,NEMA 3R, (10)IQBPLUS-72-2-US NI20AT UL LISTED MICROINVERTERS I �1 Y�1 I 4f b \ BRANCH•1 10 HANWHA OCELLS O PEAK N qIb (E)UTILITY METER DUO BLK ML-G1D+405 (N)200A AC 6-9912 AWG SKU:0-12-RAW-300,TH WN CONNECTIONS 1-#B AWG,BARE COPPER GROUND MODULE O 3-08 AWG,7HWN-2 3-#2 AWG,THWN-2 1-#8 EGO,THWN-2 1-#8 EGC.THWN-2 CONTRACTOR IN 3/4"PVC CONDUIT IN 1-1/4"PVC CONDUIT ELEMENT ENERGY, LLC. (E)200A RATED MAIN;NR'ICCEPANELL( 7470 SOUND AVE 1-#6 EGC.THWN-2 6-#8 AWG,THWN-2 MATTITUCK, NY 1 195 TILITY LICENSE# 6746 I-HI UNDERGROUND LICENSE# 52G(59-ME FEED �pF NEWY EXISTING WIRE RUN �) BREAKER �P� �(j0 A (E)GROUNDPIG ELECTRODE THROUGH CONDUIT (TOP FED) Q. (� �1P' �s� CONDUCTOR WBARECOPFER GENERAL NOTES XX O �FEssloitl A 703443 I.)THE BE55 PROVIDES MONITORING AND BALANCING CELL '� VOLTAGES,CURRENTS, AND TEMPERATURES WITHIN THE MANUFACTURER5 SPECIFICATION (N)100AMICR0 GRID SUB PANEL PROJECT NAME THROUGH WEB AND MOBILE APPLICATIONS. 3-"0AWG.THWN 2.)THE HEAT DETECTOR OR HEAT ALARM SHALL BE INSTALLED AND 1-#4 EGO.THWN INTERCONNECTED WITH 5MOKE ALARM AND THE 13E55 SYSTEM IN2"PVC CONDUIT 0 5HALL TRANSMIT AN ALARM SIGNAL VIA MOBILE PORTAL OR THE u_ w In v o cn SMOKE AND/OR HEAT ALAPM/DETECTOR IF POTENTIALLY In HAZARDOU5 TEMPERATURES OR OTHER CONDITIONS SUCH A5 IN, 12P � Lu O SHORT CIRCUITS,OVER VOLTAGE OR UNDER VOLTAGE ARE — DETECTED. N)40AI2P w z Z 3.)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON tY MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT SONNENCORE+ESS 5-#8AWG.THVVN g w SONNENCORE+ESS 1-#8EGO,THWN LLi UP-SIZING A5 REQUIRED BY FIELD CONDITIONS. IN1 PVC CONDUIT 3-#2AWG,THWN 0 w SCORE-P20 SCORE-P20 = H O ELECTRICAL NOTES 20kWh1240V 20kWh/240V 1 EGC, THVVN IN 1-114"/4'PVC CONDUIT Q J = 1.)ALL EQUIPMENT TO BE U5TED BY UL OR OTHER NRTL,AND LABELED FOR IT5 _ w Z U APPLICATION. m U 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND 90QC WET ENVIRONMENT. . '.._... 3.)WIRING,CONDUIT,AND RACEWAY5 MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO,AND LOCATED A5 CLOSE A5 P055I5LE TO THE NEAREST RIDGE,HIP,OR VALLEY. 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.2G. �' P - 511EET NAME 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF 5Y5TEM5.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS-FITTINGS AND ACE550RIE5 TO FULFILL APPLICABLE CODE5 AND STANDARDS. 1- — _ - — 3 LINE D I A. G.)WHERE SIZES OF JUNCTION 13OXE5, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 5.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SONN=-N SONNEN 5UPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. IN)100A GRID SUB PANEL 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.G.VIA WEEK LUG DRAWnNG SCALE OR IL5CO G5L-4D5T LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTOR5I5(positive/negative) (N)40A/2P N T.S. OR 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. (N)40A/2P 1 1.)THE INSTALLATION COMPUE5 WITH R327 ENERGY STORAGE 5Y5TEM5. 12.)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE 5HEET NUMBER REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING A5 REQUIRED BY FIELD \ -91DA THVW9::� i CONDITIONS. 5I-08EGC.THWN P V/ —6 ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 715"ABOVE ROOF IN 3/4"PVC CONDUIT 3-02AW/G,THWN WITH PROPER JUNCTION BOX AT EACH END. 1-#8 EGC.THWN IN1"PVC CONDUIT TAX MAP: 1 000-104.00-04.'00-01 4.000 Zotio Sign Document ID:2A768FFA-G1A9GMC_LEI7YQRIBR9QPVWZTLPKLLNOC6UQ9YN4R-C SERVICE METER O O DESIGN 4 DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGY LLC VIEW BY J.M.NABCEP CERTIFIE SOLA'"'VSTEM PHOTOVOLTAIC s • • ® ( I ) ALL LAB RE EL 5HALL BE INSTALLED IN 051112-129 ® , 9 SOLAR BREAKER re ACCORDANCE WITH THE 20 1 7 NEC EQUIPPED WITH ,,I • REVISIONS RAPID SHUTDOWN ., ® QPERATINqVOLTAOE Vbc REQU I REM ENT5. DE5CRIPTION DATE RFV • (2) ALL LOCATIONS ARE APPROXIMATE AND RV1510N 0509.2024 3 MAX�YSTEM VOLTAGE VDC' �ooaiorRaocAT� Ils$ SHORT REQUIRE FIELD VERIFICATION. SOLAR AC LOAD CENTER - OUTSIDE r< OV90JRWDEVICE (3) LABELS, WARNING(5) AND MARKING TURN RAPID SHUTDOWN SWITCH ro 0 5HALL BE IN ACCORDANCE WITH NEC THE'OFF'POSITION TO SHUT DOWN ! _ __— - --_—_-- I 1 0.2 1 (B). ! PV SYSTEM AND REDUCE e I CAUTION SHOCK WIZARD IN THE ARRAY POWER TO THIS SERVICE IS ALSO SUPPLIED (4) THE MATERIAL USED FOR MARKING __- AC DISCONNECT I FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MUST BE WEATHER RE515TANT, IN SOLAR AC LOAD CENTER- INSIDE 2� U�'LRVW- COMPLIANCE WITH NEC 1 10.2 1 (13)(3). CONTRACTOR NTHEGPRAGE -DREAMER I . ELEMENT ENERGY, LLC. ® O � WARN,ING ��-I,-� ®I� (5) THE PV SYSTEM CIRCUIT CONDUCTORS 7470 SOUND AVE SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1195 TSOURC SOURCES. BY INGOF,LL DUAL POVYERSUPPLY u COMPLIANCE WITH NEC G90.3 1 . LICENSE# 6746I-f11 SOURCES.TDTALRATINGOFALL ♦ LICENSE# 52689-ME OVERCURRINIT DEVICES EXC UDM SOURCES:UTILITY GRID MAIN SUPPLY OVERCURRENT AND PV SOLAR - ----- _--- DEVit E,SHALL NOT EXCEED ELECTRIC SYSTEM A4 6 (� CONDUIT - INSIDE BUILDING LFnYOFWMIAR -=— - - �/ OF NEW - - - - 0 - -- - - t ARNI.NG �Pz�� A G�Gs��� W,,ARN1!!NLG �'- U1/ RN NG ! THIS SERVICE METER IS ALSO SERVED BY A 2 2 ELECTRIC SHOCK HAZARD ! PHOCOVOLTAIPSAYSTEM 1 PHOTOVOLTAIC SYSTEM TERMNALSONTHEUNEAND - O r03445 !v LOAD SIDES MAY BE ENERG,ZED DO NOT ADD LOADSIN THE AROFESSIONP� CONDUIT - OUTSIDE BUILDING --= ° POOH-=- L� PROJECT NAME ® O -- --..+'__ ------ --- ---._... _ - i f '. . O L,J D co DUAL POWER SUPPLY w Z Q 0) F SOURCES:UTILITY GRID AND i PV SOLAR ELECTRIC SYSTEM' } MAIN SERVICE PANEL - OUTSIDE O DZ � z } 5 A CAUTION SOLAR CIRCUIT z 0 0 0 > acA�rrLOt� : .w Sagae,EcralcsysrEn+co cTeD. LLJ u U MAIN SERVICE PANEL - IN51DE POWER SOURCE } OUTPUT CONNECTION SHEET NAME , DO NOT RELOCATE THIS ' ® O OVERCURRENT DEVICE -- --- - - 51 G N-AG E AC DISCONNECT/6REAKER DRAWING SCALE O O /1 N .T.S. SHEET NUMBER TAX MAP: 1000- 104.00-04.00-01 4.000 q%le 0 Zoho Sign Document ID:2A768FFA-G1A9GMC_LEI7YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C ; Town of Southold May,28,*2024 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 d °•a Southold, New York 11971-0959 J Subject: Battery Energy Storage System and Roof-Mounted PV System at Schultheis Residence. Located at 1360 Sterling_Rd. Cutchogue, NY 11935 To Town of Southold: I hereby affirm and certify that, following comprehensive professional evaluations, the plans for the installation of both the Solar PV System and the Battery Energy Storage System (BESS) comply with the 2020 Residential Code of New York State, the 2020 Building Code of New York State, the 2020 Fire Code of New York State, the,2017 National Electric Code, ASCE 7-16, and other relevant industry standards and regulations. These certifications are provided in strict adherence to the governing regulations and standards applicable to such installations. For the Solar PV System, it is my professional opinion that the subject plans comply with the aforementioned codes and standards. The structural framing of the existing roof has been evaluated to support the additional loads from solar panels, with deflection and stresses within allowable limits for wind pressures and snow loads specified in the codes. The mounting locations and methods indicated in the plans are deemed adequate, and the existing building and roof framing are structurally sufficient to support the solar panels. Regarding the Battery Energy Storage System (BESS), the proposed plans have undergone thorough scrutiny and are confirmed to align with requisite codes and standards. Utilizing Lithium Iron Phosphate technology, the BESS adheres to UL9540A standards to prevent thermal runaway. The enclosure design meets fire-resistant requirements outlined in the NYS Building Code. In my professional opinion, derived from site inspections and detailed analyses, both the proposed Solar PV System and the BESS, including the enclosure system, demonstrate structural adequacy to withstand associated reactions. Please feel free to contact me if you have any questions or require further clarification. Sincerely, - <pF NE V y ��P o A c,Gs0 Gennaro Anthony Giustra. P.E. _ Great Eastern Services, Inc. * c' _�•:_ PO Box 240 m ' 24 Harvey Rd 103443 Riverhead, NY 11901 'ORo sstoNP`• Mobile: 631.235.0189 Email: jerrygiustra@gmail.com Fire separation Zoho Sign Document ID.2A768FFA-G1A9GMC_LEI7YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C required as per SCOPE OF WORK DESIGN DRAFTING C �' " � � ELEMENT ENERGY LLC TO IN5TALL A 14.58 KWDC PV SYSTEM AND A 40 KW BATTERY ENERGY STORAGE SY5TEM AT 5CHULTHE15 RESIDENCE, re erlsland REVIEW BY J.M.NABCEP CERTI`!° Heights OS 12- 29 LOCATED AT 1360 STERLING ROAD,CUTCHOGUE, NY 11935. AMENDMENT",;., THE POWER GENERATED BY THE PV 5Y5TEM AND BATTERY ENERGY STORAGE SYSTEM WILL BE INTERCONNECTED WITH Shelter Island THE UTILITY GRID THROUGH THE EXI5TING ELECTRICAL SERVICE EQUIPMENT. REVISIONS i °F5`�PT'°N DATE Fr, SYSTEM RATING Peconic y` j -- ♦�� REVISION OS-09-2024 C 40 kW AC 5TC 14.58 KW DC 5TC EQUIPMENT SUMMARY 2 UNIT5 OF 50NNEN 50NNENCORE+ 20 KW BATTERY ENERGY STORAGE 3G QCELL Q.PEAK DUO 13LK ML-G 1 O+ 405 WATT PV MODULE5 Mattnucl New Suffolk 3G ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS I IRONRIDGE XR100 MOUNTING SYSTEM el r< f� Laurel CONTRACTOR SHEET INDEX Pv-I COVER Jamespert ELEMENT ENERGY, LLC. PV-2 51TE PLAN 7470 5OUND AVE PV-3 PV PLAN e° B d9fO MATTITUCK, NY 1 195 PV-4 STRUCTURAL DETAILS PROJECT LOCATION LICENSE# G74G 1-111 PV-5 BATTERY PLAN LICENSE# 52G89-ME PV-G ELECTRICAL DIAGRAM PV-7 LABELS GOVERNING CODES _ oo QEc y° -s 2017 NATIONAL ELECTRICAL CODE. � 2020 RESIDENTIAL CODE OF NEW YORK STATE. 2020 BUILDING CODE OF NEW YORK STATE. e €r= Uj 2020 FIRE CODE OF NEW YORK STATE. m w A5CE 7-1 G AND NFPA-70. _ UNDERWRITERS LABORATORIES(UL)STANDARDS Z� O _ �� �03443 05HA 29 CFR 1910.2G9 + AROFESSIONP� r. GENERAL NOTES .'� PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE w HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK w U Q AGREE THE SAME. AERIAL VIEW 1-- o 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, U� N U > INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP g N w AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O w LU OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO I=— U) O ALL RULES AND REGULATIONS OF THE RESPONSIBLE p � _ COMMENCING WITH WORK. w JURISDICTION. = c9 I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS O U m � WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE B_ U) — U THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS 0 ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS THE OCCUPATIONAL SAFETY AND � CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATIOON.THIS SHALL INCLUDE, BUT ARE NOT LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM 77EET AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY None 5. ALL STRUCTURAL STEEL SHALL BE FRO FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 SCAFFOLDING STAIRS, ETC.. AS WELL AS PERMANENT COVE SPECIFICATIONS. CONSTRUCTION. G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE N DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. UN CODES REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. °RAwwG SCALE CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS 8. THESE DRAWINGS AS INSTRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE IT IN A LEGAL MANNER ON n 1 .T.5. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 1 WEEKLY BASIS LE SOONER IF CONDITIONS WARRANT. I V PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. I F L THE COMPLETION OF WORK, THE SITE FA IL CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE shEE NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV- RESULT OF HIS WORK. TAX MAP: 1000- 1 04.00-04.00-01 4.000 Zoho Sign Document ID 2A768FFA-G1A9GMC—LEI7YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C LEGEND ®o O EMTING UTILITY METER N ELEMENT OENERGY LLC MAIN SERVICE PANEL O° REVIEW BY J.M.NABCEP CERTIF'F' NEW PV SUB-PANELS / 051 112-129 A/C DISCONNECT COMBINER INVERTERS (P GND ELECTRODE 270 a REVISIONS MM PV MODULE 24po ®r7 �90°L� DE5CRIFTION DATE R`✓ RACKING RALL 120° ` REV1510N 05-09-2024 2'01 0 O ATTACHMENT POINT 800 o15po ---RAFTERS 0 ROOF PITCH ANGLE S eSUNRUN METER NEW PV AC 15C NNECT ®`ENT EW BE55 UNITS IN THE GARAGE FIRST FLOOR 0PLUMBING VENT I TING UTILITY METER 15TING MAIN ELECTRICAL SERVICE PANEL IN BASEMENT ®SKY LIGHT ®CHIMNEY CONTRACTOR ®COMPOSITE SHINGLES 8 ELEMENT ENERGY, LLC. GOOD CONDITION "POTENTIAL SHADING ISSUES ® 7470 SOUND AVE "7R)M/REMOVE AS NECESSARY MATTITUCK, NY I 1052 LICENSE #G74G I-HI LICENSE# 52G8O-ME ACCESS ROOF ��OF NEI A ACCESS ROOF � u/ 5�e 18"FlRE SETBACK QRIDGE ARO�SSIONP�' 18"`IRE SETBACK @RIDGE PRCJEGT NAME OIll Ln O O LLJ w o o 201-1" r 17'- 1 0° z z 0 p w w N = 1— U o N O ILJ U O � - v 5MEET NAME SITE PLAN ON5TRUCTION NOTES 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE DRAWING SCALE MANUFACTURERS INSTALLATION INSTRUCTIONS. 1 /8 /Q11 _ I 1_01 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. v 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.)THE BATTERY ENCLOSURE SHALL BE COMPLIANT WITH 2O20 NY5 FIRE CODE THE BATTERY ENCLC5UREMU5T ADHERE TO THE FIRE SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE FIRE CODE (NY5 FIRE CODE R302). IT IS IMPERATIVE THAT THE EXISTING GARAGE BE 5MEET NUMBER INSPECTED AND APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO ENSURE COMPLIANCE. PV-2 PLEASE BE ADVISED THAT WHILE WE ARE NOT CERTIFYING THE ENCLOSURE OURSELVES, IT IS UNDERSTOOD THAT IT MUST MEET THE AFOREMENTIONED FIRE CODE REGULATIONS. TAX MAP: 1 000- 1 04.00-04.00-0 1 4.000 Zoho Sign Document ID.2A768FFA-G1A9GMC_LE17YQRIBR9QPVWZTLPKLLNOC6UQ9YN4R-C LEGEND ^/ o EXISTING UTILITY METER '• EDE51GN b DRAFTING BY: ® NT ENERGY LLC MAIN SERVICE PANEL Do M.NABCEP CERT"NEW PV SUB-PANELS 1 1 12-129 A/C DISCONNECT COMBINER NVERTERS I ELECTRODE 270° REVISIONS GND a _ o DESCRIPTION DATE REV PV MODULE 240° 90 E REV15ION 05-09-2024 C —RACKING RAIL 2 1 0D 120o 30'x 30"GROUND ACCE55 TYP. O ATTACHMENT POINT 180o 150. ---RAFTERS -*--ROOF PITCH ANGLE S NEW PV AC Q15CONN CT EW BE55 UNIT5 IN THE GARAGE FIR5T FLOOR BSUNRUN METER ®VENT EXISTING UTILITY MET 15TING MAIN ELECTRICAL SERVICE PANEL IN BASEMENT OPLUMBING VENT ®SKY LIGHT CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES ® /,J ELEMENT ENERGY, LLC. GOOD CONDITION IPOTENRAL SHADING IMEs ;® 7470 SOUND AVE TRIM/REMOVE AS NECESSARY MATTITUCK, NY 1 195 ® LICENSE# G74G I-HI ACCESS ROOF LI CEN5E ACCESS ROOF �,�P��`� AE Gs�•p� m � '� w -------------- I b"F1RE SETBACK QRIDGE � -�1o'�n�sE-(� �� I s FIRE sETaACK @woGE ��SS10NP� PROJECT NAME O U o M 201- 1 " IL.I z Q m 17'-10" o _ N w z z 62 Q+ ® O m V PANEL TYP. O w w t N O O = w � �q U O U `Y) 1 U STP.ING/GONNEGTION TYP. -7 ARRAY#I ARRAY# 23 MODULES 13 MODULES 5HEET NAME 22'PITCH 220 PITCH CRO-INVERTERTYF. CONSTRUCTION SUMMARY I G5°AZIMUTH 1650 AZIMUTH P V FLAN (3G) QCELL Q.PEAK DUO BLK ML-G 1 0+ 405 WATT PV MODULES (DIMENSIONS: 74"X 4 1.I"X 1.3") (3G)ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS (GO)ATTACHMENT POINTS @ G4"O.C. MAX. DRAWING SCALE (249.G) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) I /Q II = I I_OI CONSTRUCTION NOTES CJ 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 5"EET NUMBER 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. PV-� 4.)WALLS AND CEILING INSIDE THE BATTERY ENCLOSURE SHALL BE LMINATED WITH 5/8"TYPE X SHEETROCK OR EQUIVALENT 5.)THE DOOR OF THE BATTERY ENCLOSURE SHALL BE 30 WIDE MINIUMUM 20 MINUTE FIRE RATED DOOR. TAX MAP: 1 OOO- 1 04.00-04.00-0 1 4.000 Zoho Sign Document ID:2A768FFA-G1A9GMC_1_E17YQRIBR90PWVZTLPKLLNOC6UQ9YN4R-C LOAD CALCULATION ARRAY#I ARRAY s= ITEM DE5CRIPTION ARRAY5#1-2 RB Rid a Bean 5oard 2"X 10"D. FIR DESIGN#DRAFTING BY: ELEMENT ENERGY LLC R Rafter. 2"X 8"D. FIR I G"O.C. MODULE WEIGHT(Lbs) 48.4 48.4 REVIEW BY J.M.NABCEP CERTIFIE (D) Deckin 5/8"PLYWOOD 051 1 12-129 #OF MODULES 23 13 K Knee Walls 2"X G"D. FIR 0 1 G"O.C. TOTAL MODULE WEIGHT(Lbs) 11 13.2 G29.2 J Cellin Joist 2"X 8"D. FIR 611 1 G"O.C. PIM5ION5 TOTAL LENGTH OF RAIL(Ft) 159.5 90.1 P Pitch 22° oE5 H Horizontal 5 an of REVVISION 183"MAX. 1510N DATE Rev 05-09-2024 C RAIL WEIGHT PER FOOT(Lbs) 0.G8 0.G8 TOTAL RAIL WEIGHT(Lbs) 106.5 G 1.3 #OF 5TRANDOFF5 3G 24 (R� (R6) WEIGHT PER STRANDOFF(Lbs) 2 2 TOTAL 5TANDOFF WEIGHT(Lbs) 72 48 TOTAL ARRAY WEIGHT(Ws) 1293.7 733.5 POINT LOAD(Lbs) _ 30.5 CONTRACTOR TOTAL ARRAY AREA(5q Ft) 492 G 275.3 w ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(IJn15q Ft) 2,G 2.7 7470 SOUND AVE MATTITUCK, NY I 155 GROUND WIND DESIGN SEISMIC 5UBJECT TO DAMAGE FROM WINTER ICE BARRIER AIR MEAN LICENSE#G74G I-111 SNOW DESIG FLOOD N Frost DESIGN UNDERLAYMENT HAZARD59 FREEZING ANNUAL / LICENSE# 52G89-ME LOAD' Speeda Topographic Special Wuidborne CATEGORY' TEMPI REQUIREDh INDEXi TEMP) (mph) effectsk wend region' debns zone"' Weathering' line b Termite` depth 20 140 NO NO NO B SEVERE 3 FT HEAV° 15°F YE5 ZONE X 599 51°F / `��F NEt�,y �P Pg0 A MANUAL J DESIGN CRffERIA" Indoor s Winter Summer dell n Heatm temperature n Elevation latitude heatin coolin Altitude correction factor g Design temperature cooling i p m W 9 g tempera difference (J) y� ture �O ^703443 108 FT 4 I°N 15°F 8G°F 1.00 70'F 75'F 55°F �1 Wind Win tF' Cooling Coincident temperature difference velocity velocity t bulb Daily rang Winter e humidit Summer humidity _ heating We u y cooling (� PROJECT NAME ROOF FRAMING DETAIL I X/ 1 5°F 5 MFH 7.5 MPH 72°F MEDIUM(M) 40:7. 32 GR @50%PH O ll) For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m ILUis. w Z Q � a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth N p 0 — strength required for weathering shall govem.The weathering column shall be filled in with the weathering index,"negligible,"moderate"or"severe"for concrete as MODULE MOUNTING CLAMP N N U }. determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. � � Z Z b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction — shall fill in the frost line depth column with the minimum depth of footing below finish grade. SOLAR MODULE g N E� U C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. O W H d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined 5TAINL.E55 STEEL 3/8 d) _ U1 BOLT AND NUT H O on a site-specific basis in accordance with Section R301.2.1.4. c,LLJ � 0 U e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York N _ State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.(Also O m U see Figure R301.2(1).] NRIDGE ALUMINUM RAIL [I/ f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New ALUMINUM"V BRACKET n York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: ALUMINUM FlASHudG i.The accompanying Flood Insurance Rate Map(FIRM), SHEET NAME ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. STRUCTURAL DETAILS h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the A5PHALT 5HINGLE ROOF effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5/I G"x G'5TAINLE55 1. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WITH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" 2 112"MIN THREAD j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method PENETRATION SEALED (Base 32°F)." WITH GEOCEL 4500 DRAWING 5CALE k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the (EQUIVALENT OR BETTER) jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall indicate"NO"in this part of the table. N . I I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with I v "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. 0. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at n` elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. MOUNTING DETAIL I r v 4 (') See Figure R301.2(4)B. TAX MAP: 1 000-104.00-04.00-014.000 Zoho Sign Document ID:2A768FFA-G1A9GMC-LEI7YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C CONSTRUCTION SUMMARY LEGEND DESIGN&DRAFTING BY: LLC (2) UNITS OF 50NNEN SONNENCORE+ 20 KWH BATTERY OMAINISE MCC P METER ELEMENT ENERGY CE (DIMENSIONS: 27"X G9.5"X 14") IN ATTACHED GARAGE MEN SHRNCE PANEL REVIEW BY J.M.NABc2P CERTIFIE NEW PV SUB-PANELS 051112-129 WITH REQUIRED FRONT CLEARANCE OF THIRTY-51X INCHES A/C DISCONNECT COMBINER INVERTERS r—s s—s}• a �j GNo ELECTRODE REVISIONS CONSTRUCTION NOTES =PV MODULE DE5CRIPTION DATE REv REV1510N 05-09-2024 C 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE —RACKING RAIL WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. sONNEN o ATTACHMENT POINT 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I WR SONNENCORE+ -__RAFlElRS 20KW BESS 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE �� 70• UNITS PROOF PITCH MOLE FIELD VERIFICATION. N 4.) CONDUIT RUN/RACEWAY FOR BATTERY ENERGY `��� 4— ®VENT METER STORAGE SYSTEM (BESS)SHALL BE LOCATED WITHIN FIRE �� `� VE RATED AREA. THE CONDUIT/WIRE RUNS TO THE EXISTING ► O 1 OPLUMBINc vENT MAIN SERVICE PANEL AND TO THE PLP IN PVC CONDUIT dJ °�" s ®SKY LIGHT INSIDE OF THE EXISTING BASEMENT AND THEY SHALL BE CHIMNEY® CONTRACTOR LOCATED INDOORS. COMPOSITE SHINGLES ELEMENT ENERGY, LLC. 5.)THIS BESS SYSTEM IS COMPLIANT WITH THE SECTION ®GOOD CONDITION 7470 SOUND AVE R327 OF THE INTERNATIONAL RESIDENTIAL CODE, AS fN _RIM/l BA SHADING N IssuEs BO _'.TRIM/REMOVE AS NECESSARY MATTITUCK, NY 1195 AMENDED BY THE NEW YORK STATE UNIFORM CODE. ,o• LICENSE # G74G I-t11 G.)THE BATTERY LOCATION MUST ADHERE TO THE FIRE SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE t LICENSE# 52G89-MF FIRE CODE(NYS FIRE CODE R302). STUD WALL �\ of NEWy A o,s0� �MIN FI - T �� ille DOOR m W �Q 1034A rr—r ARo�SsloNP� 2z �_„- 8eparat�a�690 pa w CL/ DC z z g N w � �XT _ L o N O w o = �p U O O L U SHEET NAME BATTERY PLAN Fb IF 11211 _ 1 1_01 y zr-a• [GARAGE PLAN] PV-5 TAX MAP: 1 000- 1 04.00-04.00-01 4.000 Zoho Sign Document ID 2A768FFA-G1A9GMC LE17YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C (N)ENPHASE COMBINER BOX MODEL DE51GN s DRAFTING BY: 2-#12 AWG SKU.Q-12-RAW-300,THWN NO#X2-IQ-AM1-240� (N)tODA RATED (10)IQ8PLUS-72-2-US—. 1-#8 AWG.BARE COPPER GROUND ESSENTIAL LOAD PANEL ELEMENT ENERGY LLC MICROINVERTERS 1PH.120'240VBDHZ REVIEW BY J.M.NAECEP CERTIFIE CELL WIRELESS IN) 12P WIN BRANCH-1 MODEM COMMS BREAKER O51( 2-129 TOP FED) 10 HANWHA OCELLS Q PEAK DUO BLK ML-G10+405 IQ GATEWAY (N)60A FUSED REV151ON5 =NIIRR� SPLUS-72-2-US N) AC DISCONNECT DE5CRJPTION DATE REV ROINVERTERS SQUARE D D322NRB WITH 50 A FUSES, TO OTHER LOAD REVISION 05-09-202a C ELLS Q PEAK N)2DA/}� KNIFEBLADE, m -G1O+4D5 ro2DA/�� LOCKABLE,NEMA 3R,SPLUS-7z-2-UsUL LISTED ROINVERTERSCH-1(E)UTILITY METER CELLSQ PEAK N IF L-G10+405 (N)200A AC - 6-#12 AWG SKU.Q-12-RAW-300.THWN CONNECTIONS 1-*8 AWG,BARE COPPER GROUND MODULE O3-08 AWG,THWM-2 3-*2 AWG TI W 17 1-08 EGC,THWN-2 1-08 EGC,THM4.2 CONTRACTOR IN 3/4'PVC CONDUIT IN 1-1/4"PVC CONDUIT g (E)MDA RATED ... ELEMENT ENERGY, LLC. MAN SERVICE PANEL(1) ,PH,,2N240V 6DH2 � 7470 SOUND AVE 8-#6EGC,1'HW-2 MATTITUCK, NY 1 195 1-#8 EGC,THWM-2 TO UTILITY LICENSE# G74G I-HI UNDERGROUND LICENSE# 52G.59-ME FEED - - --EXISTING WIRE RUN (EI2DDA l2P MAN �. (G Orc NEC �y THROUGH CONDUIT BREAKER 0. (El GROUNDWG ELECTRODE TOP FED) Q- ,�P� _QO A CONDUCTOR #BARE COPPER C13P' r W LL GENERAL NOTES ^ "�i\ —'a db 103443 1.)THE 5E55 PROVIDES MONITORING AND BALANCING CELL SSK7� VOLTAGES,CURRENTS, AND TEMPERATURE5 WITHIN THE MANUFACTURER'5 SPECIFICATION ( MICRO THROUGH WEB AND MOBILE APPLICATION5. GRID IDsuBPANEL PROJECT NAME 2.)THE HEAT DETECTOR OR HEAT ALARM 5HALL BE IN5TALLED AND I-so EGCA THWI INTERCONNECTED WITH SMOKE ALARM AND THE 15E55 SYSTEM IN 2'PVC CONDUIT 5HALL TRAN5MIT AN ALARM 51GNAL VIA MOBILE PORTAL OR THE SMOKE AND/OR HEAT ALARM/DETECTOR IF POTENTIALLY w Ln HAZARDOU5 TEMPERATURE5 OR OTHER CONDITIONS 5UCH A5 POA,/ LJ Q QO SHORT CIRCUIT5,OVER VOLTAGE OR UNDER VOLTAGE ARE 3)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BA5ED ON L Z MINIMUM CODE REQUIREMENT5 AND ARE NOT MEANT TO LIMIT 5-#8 AWG.THWNaz IL/ Z UP-51ZING A5 REQUIRED BY FIELD CONDITION5. SONNENCORE+ESS SONNENCORE+ESS 1-#8EGO THWIN g N t� LL SCORE-P20 SCORE-P20 IN 1"PVC CONDUIT 3-92 AWG,THWN C) W LLJ Z) ELECTRICAL NOTE5 2DkWn/240V 201(WFl/240V #8 EGC,THWN _ 1— IN t-1/4"PVC CONDUIT � � 0 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NKTL,AND LABELED FOR 1T5 � J W n � APPLICATION. O U c) 2.)ALL CONDUCTOR5 5HALL BE COPPER,RATED FOR GOO V AND 909C WET ENVIRONMENT. 0_ U) — U 3.)WIRING,CONDUIT,AND RACEWAY5 MOUNTED ON ROOFTOP5 5HALL BE ROUTED O DIRECTLY X - 0 TO,AND LOCATED A5 CL05E A5 P05515LE TO THE NEARE5T RIDGE,HIP,OR VALLEY. 4.)WORKING CLEAKANCE5 AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT 5HALL _ COMPLY WITH NEC 110.2G. i 5HEET NAME 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF 5Y5TEM5.CONTRACTOR 5HALL — FURNI5H ALL NECE55ARY OUTLETS,SUPPORTS,FITTINGS AND ACESSORIES TO FULFILL ^ AFFUCA15LE CODE5 AND STANDARDS. LINE D I A. G.)WHERE 51ZE5 OF JUNCTION BOXE5, RACEWAY5,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR 5HALL 51ZE THEM ACCORDINGLY. i 7.)ALL WIRE TERMINATIONS 5HALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.)MODULE GROUNDING CLIP5 TO BE IN5TALLED BETWEEN MODULE FRAME AND MODULE 5UPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. INI 100A GRID SUB PANEL 9.)MODULE 5UPPORT RAIL TO BE BONDED TO CONTINUOU5 COPPER G.E.C.VIA WEEK LUG DRAWING 5CAL OR IL5CO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(postive/necgative) Q.A QR N .T.10.)THE DC 51DE OF THE PV 5Y5TEM 15 UNGROUNDED AND 5HALL COMPLY WITH NECG90.35. 1 1.)THE IN5TALL.ATION COMPUE5 WITH P327 ENERGY 5TORAGE 5Y5TEM5. 12.)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE 5A5ED ON MINIMUM CODE REQUIREMENT5 AND ARE NOT MEANT TO LIMIT UP-51ZING A5 REQUIRED BY FIELD CONDITION5. s-#10 AWG,THWN 1-rS THwN PV-5 ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF IN 3M"PVC CONDUIT 3-#2 AWG,THWN WITH PROPER JUNCTION BOX AT EACH END. 1-08EGC,THWN IN 1"PVC CONDUIT TAX MAP: 1000- 104.00-04.00-014.000 Zoho Sign Document ID:2A768FFA-G1A9GMC_LE17YQRIBR9QPWVZTLPKLLNOC6UQ9YN4R-C SERVICE METER OI O �E EME c CRAFTING RGY C INSTALLATION NOTE ELEMENT NECEPCE REVIEW BY J.M.NABCEP CER?'.` SOLARPVSYSTEM PHOTOVOLTAIC - • • • ( I ) ALL LABEL 5MALL BE INSTALLED IN III 2-129 00 � IEQUIPPED WITH SOLAR BEER • •• ACCORDANCE WITH TfIE 2017 NEC REVISIONS RAPID SHUTDOWN ® OPERATING REQUIREMENTS. DE5CRFnON DATE RfV OPERATING (2) ALL LOCATIONS ARE APPROXIMATE AND REV15ION 05-09-2024 C MAX SYSTEM SOLAR AC LOAD CENTER - OUTSIDE DO NOT RELOCATE TM O VOLTAGE • REQUIRE FIELD VERIFICATION. OvERCURI rDEVICE ` (3) LABELS, WARNING(5) AND MARKING O3 TURN RAND SHUTDOWN SWITCH To '; Og 5MALL BE IN ACCORDANCE WITH NEC THE'OFF POSITION TO SHUT DOWN 1 1 0.2 1 (B). PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY AC DISCONNECT PGWERTOTNSASERuMEESA Sp M (4) THE MATERIAL USED FOR MARKING FROM THE FOLLO NG SOURCES 1VITH - D=0"NEMLOG"W°" "" MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - IN51DE O m 4= CONTRACTOR � a ~TF COMPLIANCE WITH NEC 1 1 0.2 1 (B)(3). ELEMENT ENERGY, LLC. ki WARNIN �.,� (5) THE PV 5Y5TEM CIRCUIT CONDUCTORS 7470 SOUND AVE ® O7 ® 1 1 ' "` 5MALL BE LABELED INSTALLED IN MATTITUCK. NY 1 195 EFEDBYWA-� DUAL POWER SUPPLY LICENSE # G74G I-111 TUKRUMOFALL SOURCES:UTILITY GRID �• COMPLIANCE WITH NEC G90.3 1 . LICENSE # 52G89-ME DEVM W1M APPLY G46Smom AND PV SOLAR OEM S+MLLNOf ELECTRIC SYSTEM CONDUIT - IN51DE BUILDING OFeUSBAR OF NEIV 3O ARNING ?�0 G�Gs��* IN v THIS SERVICE METER e IS ALSO SERVED BY A m W ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM I PHOTOVOLTAIC SYSTEM TERMINALS ON THE LINE AND ! COMBMIER PANEL l� LOAD SIDES MAY BE ENERGII DD ZED DO NOT A LOADS OA �03443 CONDUIT - OUTSIDE BUILDING "* a"PMT N - I �FEsstoNP� ® � IL1 Lf) RALOWER SUPPLY :2 U 0 In ! SOURCES:UTIM GM AND IZU PV SOLAR SECT=SYSTEMS } — MAIN SERVICE PANEL - OUTSIDE N w } A CAUTION SOLAR CIRCUIT z z O - w wUj A CAUTION SOLAR ELEC'RtC SYSTEM CONNECTED O = U U O - • • O N m U G 0 MAIN SERVICE PANEL - INSIDE OPERATING CURRENT AMPS OPERATING VOLTAGEVOLTS POWER SOURCE OUTPUT CONNECTION I SnEET NAME ® O DO NOT RELOCATE THIS OVERCURREINT DEVICE 51GNAGE AC DISCONNECT/BREAKER DRAWING SCALE 10 03 OO N .T.S. PV-7 TAX MAP: 1 000- 1 04.00-04.00-01 4.000 Zoho Sign Document ID.2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEtZIYTS7U_QIGXIW SCOPE OF WORK DESIGN6DRAFTING BY: - -- ELEMENT ENERGY LLC TO IN5TALL A 14.55 KWDC PV 5Y5TEM AND A 40 KW BATTERY ENERGY 5TORAGE 5Y5TEM AT 5CHULTHEI5 RESIDENCE, % Shehe island IEW BY J.M.NABCEP CERTIF LOCATED AT 13GO 5TERLING ROAD,CUTCHOGUE, NY 1 1935. 25 Heights - 2_129 THE POWER GENERATED BY THE PV 5Y5TEM AND BATTERY ENERGY 5TORAGE 5Y5TEM WILL BE INTERCONNECTED WITH ' i SheHe,Isiane THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS SYSTEM RATING JES �ON °ATE9-2 "`` ,Dole��� i REVISION OS-09-2024 REVISION 05-23-2024 C 40 kWh AC 5TC 14.55 KW DC 5TC REvsION os-05-2024 EQUIPMENT SUMMARY REV 510N 2_182024 North Haven 2 UNIT5 OF 5ONNEN 5ONNENCORE+ 20 KW BATTERY ENERGY 5TORAGE Noyack Sag Harbor 3G QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES - 3G ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS I IRONRIDGE XR100 MOUNTING 5Y5TEM S H E ET I N D EX CONTRACTOR Pv-I COVER e 41 ELEMENT ENERGY, LLC. PV-2 51TE PLAN Q� 7470 SOUND AVE PV-3 PV PLAN �dgd mpfo° MATTITLICK, NY 1 105 PV-4 STRUCTURAL DETAILS PROJECT LOCATION LICENSE#G746 I-HI PV-5 BATTERY PLAN LICENSE# 52G89-ME PV-G ELECTRICAL DIAGRAM PV-7 LABEL5 GOVERNING CODES ��Of NEtV .. LPtOAG�GQ,P 2017 NATIONAL ELECTRICAL CODE. *:;x • ? n 2020 RESIDENTIAL CODE OF NEW YORK STATE. ' ` rA 2020 BUILDING CODE OF NEW YORK STATE. "' , ' m L7 2020 FIRE CODE OF NEW YORK STATE. to A5CE 7-1 G.AND NFPA-70. r• Z - UNDERWRITERS LABORATORIES(UL)STANDARDS 05HA 29 CFR 1 910.2G9 3 443 �� �0 �O ARO�SSIONP� GENERAL NOTES 'y PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE SF O w LO AGREEHIMSELTHE SAMEWITH INTENT OF THESE PLANS AND MAKE WORK AERIAL VIEW w z Q Co 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED O 2 — APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP LU z z INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, g oz AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O wUj 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND U ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO N O COMMENCING WITH WORK. O J O JURISDICTION. I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR = � _ �p � 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS O U m WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE (L in — U THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, l L yqv 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT COVE SPECIFICATIONS. CONSTRUCTION. �(', 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE v DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND ACCORDANCE WITH N.E.C. 8 ((�- t UN CODES REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING v CONDITIONS PRIOR TO ORDERING MATERIALS AND ` DRAWING SCALE 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. Z Q2J CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON �p 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND e A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. g� ` N WH SHALL REMAIN THE PROPERTY OF THE ENGINEER ETHER THE PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED �9O OV_0 d THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE \�� o{S EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE 0`�� SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV— RESULT OF HI5 WORK. TAX MAP: 1 000- 104.00-04.00-01 4.000 Zoho Sign Document ID:2A768FFA-2MLDY-gI01QJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW (N)ENPHASE COMBINER BOX MODEL IDDA DE51GN C DRAFTING BY: 2-#12 AWG SKU.D-12-RAW-300,THWN NO#X2-IQ-AM1-24D-4 ESSENTIAL)LOAD RATED (1 ICROINVERT RS 1-#8 AWG,BARE COPPER GROUND ELEMENT ENERGY LLC MICROwvER7ERS 1PH.1a�z4ov60Hz REVIEW BY J.M.NABCEP CERTIFIE CELL WIRELESS 3-#8 AM,THWN-2 (N)WA 12P MAIN 051 1 1 2-1 29 BRANCH-1 MODEM COMMS 1-08 EGC.THWN!-2 BREAKER TOP FED) 10 HANWHA OCELLS O PEAK IN 3/4'PVC CONDUIT DUO BLK ML-G10+405 1O GATEWAY (N)60A FUSED REVISIONS (10)IOSPLUS-72-2-US M AC DISCONNECT DE5CRIFTION DATE REV MICROINVERTERS m SQUARE D D322NRB REV15ION 05-09-2024 5 WITH 50 A FUSES, TOOTHERLOAD 10 HANWHA BRANCH-1 D PEAK IN N)mom KNIFEBLADE, REV15ION 05-23-2024 C DUO BLK ML-G10+405 /� LOCKABLE,NEMA 3R, UL LISTED /tom REV15ION OG-05-2024 D (10)IQ8PWS-72-2-US MICROINVERTERS 4 N RFA5ION 12-18-2024 If 4� BRANCH-1 (E)UTILITY METER 10 HANWHA OCELLS-OPEAK N 4f� (N)2(W DUO BLK ML-G10+405 I (N)200A PATH-THROUGH - AC CONNECTIONS _ MODULE O6-#12 AWG SKU Q-12-RAW-300,THWN 3-#2 AM THWN-2 " 1-#8 AWG,BARE COPPER GROUND 1-*8 EGC,THWN-2 IN 1-1/4"PVC CONDUIT g CONTRACTOR (E)200A RATED •� ELEMENT ENERGY, LLC. MAIN SERVICE PANEL(1) 7470 SOUND AVE 1 PH,12D/24DV60W '..� 6-#6 AVrG.THWN-2 MATTITUCK, NY 1 195 1-7t8 EGC,THWN-2 TO UTILITY LICENSE#G74G I—HI UNDERGROUND FEED LICENSE# 52G89—ME 7d. G!OF NEW EXISTING WIRE RUN (EI mDA BREAKER2PMAIN LL O, P,(` O A (E)GROUNDINGEI-ECTRODE THROUGH CONDUIT (TOP FED) CONDUCTOR N BARE COPPER 0 Uj fin fc GENERAL NOTE5 m 7344 1 1.)THE 5E55 PROVIDES MONITORING AND BALANCING CELL (N)210AI2PBREAKER �Aio_ t_��p� VOLTAGES,CURRENTS, (F AND TEMPERATURES WITHIN THE MANUFACTURERS SPECIFICATION IN)1ODA MICRO THROUGH WEB AND MOBILE APPLICATIONS. GRIDsuBPANEL PROJECT NAME 3-i2 AWG,T. 2.)THE HEAT DETECTOR OR HEAT ALARM SHALL BE IN5TALLED AND 1-06 EGC,T 1WN INTERCONNECTED WITH SMOKE ALARM AND THE BE55 SYSTEM IN IAA PVC CONDUIT O SHALL TRANSMIT AN ALARM 51GNAL VIA MOBILE PORTAL OR THE (L W Lf) 5MOKE AND/OR HEAT ALARM/DETECTOR IF POTENTIALLY U n M HAZARDOUS TEMPERATURES OR OTHER CONDITIONS 5UCH A5 IN)40A/2P W 0 SHORT CIRCUITS,OVER VOLTAGE OR UNDER VOLTAGE ARE g _ DETECTED. N)40A 12P }� (f) 0 3.)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE 13A5ED ON � Z Z MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT Arlf] ,THWN SONNENCORE+ESS SONNENC .THWN g N OJ[ W UP-51ZING A5 REQUIRED BY FIELD CONDITIONS. SCORE-P20 SCORNDUIT 3-#2NAG,THWN Q w H WIN ELECTRICAL NOTE5 20kWh/240V 20kW 1 14"Ecc,CONDUIT N = IN 1-1/4"PVC CONDUIT Q J � O 1.)ALL EQUIPMENT TO BE U5TED BY UL OR OTHER NRTL,AND LABELED FOR IT5 O w Z O Q) �p U APPLICATION. U) U ch 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND 90QC WET ENVIRONMENT. O N U 3.)WIRING,CONDUIT,AND RACEWAY5 MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY _ TO,AND LOCATED A5 CLOSE A5 P0551BLE TO THE NEAREST RIDGE, HIP,OR VALLEY. 4.)WORKING CLEARANCES AROUND ALL NEW AND EX15TING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.2G. 5HEET NAME 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF 5Y5TEM5.CONTRACTOR SHALL ——, FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODE5 AND STANDARDS. 3 LINE D I A. G.)WHERE 51ZE5 OF JUNCTION BOXE5,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 5.)MODULE GROUNDING CUPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SON N E SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. (N)100A GRID SUB PANEL 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK LUG DRAWING 5CALE OR IL5CO GBL-4DBT LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5ltive/negafive) Lj Li QQA n ITOR N I10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC90.35. 1 1.)THE INSTALLATION COMPUES WITH P327 ENERGY STORAGE 5Y5TEM5. 12.)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE aJMBER REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING A5 REQUIRED BY FIELD CON DITION5. 5-#10 AWG.THWN 1I"PVCC CONDUIT fD — THWN ALL CONDUC-FORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF IN 314"PVC CONDUIT 3-#2 AM,THWN I V WITH PROPER JUNCTION BOX AT EACH END. 1-#6 EGC,THWN IN 1"PVC CONDUIT TAX MAP: 1000-104.00-04.00-014,000 Zoho Sign Document ID.2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW SERVICE METER O O LREVIEW N 6 DRAFTING C INSTALLATION NOTE ENTENERGYLLC M.NA5CEP CERTIFIE SOLAR PV SYSTEMPHOTOVOLTAIC • • • ( 1 ) ALL LABEL 5HALL BE INSTALLED IN 51112-129 EQUIPPED WITH ! SOLAR BREAKER ° ACCORDANCE WITH THE 2017 NEC REVISIONS RAPID SHUTDOWN ® •• •--T'-G VnITAGE VDC REQUIREMENT5. DESCRIPTION DATE REV OPERATING CURRENT A (2) ALL LOCATIONS ARE APPROXIMATE AND �V151°" 05_09-2024 9 MAX SYSTEM VOLTAGE VIDC 1 REQUIRE FIELD VERIFICATION. REV 51°" 05-23-2024 C SOLAR AC LOAD CENTER - OUTSIDE ! DO NDT RELOCATE THIS, �• REV1510N 06-05-2024 D t OVERCURRENTDEVICE (3) LABELS, WARNING(5) AND MARKING REVI51ON 12-18-2024 E SHALL BE IN ACCORDANCE WITH NEC TWOFF POSITION TO SWT� O 1 1 0.2 1 (B). i PV SYSTEM MD REDUCE CAUTION ` SHOCK H Wld THE WRAY AC DISCONNECT POWER-DTHISSERVIC M ALSO f11H® (4) THE MATERIAL USED FOR MARKING FROM THE FDUOWIRO SOURCES WIT" MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE O COMPLIANCE WITH NEC 1 1 0.2 1 (B)(3). CONTRACTOR (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. _ �„ . 7470 SOUND AVE ® O ® 1 1 a ' "° I SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 195 TMEQOP"FEDBYNXTRE I DUAL POWER SUPPLY ? LICENSE # G74G I-HI RCESTOTA SOQLRATMOFALL I a MT elCURR DEVICES.UZUJDM; COMPLIANCE WITH NEC 690.3 1 .SOURCES: LICENSE# 52G89-ME ImN SuaPLr oraaalAaE/1T AND PV SOLAR OEUICE SW1LL IIQf FJOC® _ELECTRIC SYSTHA r CONDUIT - INSIDE BUILDING ARRMpTrOFWSBAR - pF NEw THIS SERVICE METER 1 IS ALSO SERVED BY A = m L U ELECTRIC SHOCK HAZARD I PHOTOVOLTAIC SYSTEM I PHOTOVOLTAIC SYSTEM TEFURALS ON THE LINE AND COMBINER PANEL L SDES IUW BE ENERGM DO NOT ADD LOADS F� 103443 CONDUIT - OUTSIDE BUILDING ) SsIl N THE OPEN rL=IXN ® ® PROJECiNAME <Y O LLI Ln qDLIALPOWIEBRtSUPPMLY w z Q (3) LLJ I PV SOLAR ELECTRIC SYSTM 0,c — MAIN SERVICE PANEL - OUTSIDE N w U } A CAUTION SOLAR CIRCUIT z z o w SOLARELECTM SYSTEM COW&CM p S U MAIN SERVICE PANEL - INSIDE ' POWER SOURCE OUTPUT CONNECTION 5tiEE7 NAME ® O DO NOT RELOCATE THIS OVERCURCURRENT DEVICE - =-- I NA E AC DISCONNECT/BREAKER DRAWING 5CAL` 000 � ® N .T.5. s�EE-NMBE� PV-7 TAX MAP: 1000-104.00-04.00-01 4.000 Zoho Sign Document ID 2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U-QIGXIW LEGEND �E)aSTING UTIUTf METER N EELEMENTDENERGYG BY: MAIN SERVICE PANELO° M.I NABCEP5 CERTIFIE NEW PV SUB-PANELS / A/C DISCONNECT COMBINER INVERTERS W GND ELECTRODE 270 d REVISIONS PV MODULE 240- �90,C DE5CRIPTI0N DATE REV RACKING RAIL ` RE0510N 05-09-2024 B 210o D 120o U0510N 05-23-2024 C 0 ATTACHMENT POINT 180 o 150o REV15ION 04-05-2024 D ---RAFTERS REV15ION 12-15-2024 E F ROOF PITCH ANGLE TISUNRUN METER NEW PV AC D15CONN T NET EW BE55 UNITS IN THE GARAGE FIRST FLOOR O PLUMBING VENT EX15TIN' UTILITY M 15TING MAIN ELECTRICAL SERVICE PANEL IN BA5EMENT ®SKY UGHT ®CHIMNEY CONTRACTOR ®COMPOSITE SHINGLES e ELEMENT ENERGY, LLC. GOOD CONDITION POTENTIAL SHADING ISSUES ® 7470 SOUND AVE TRIM/REMOVE AS NECESSARY MATTITUCK, NY 1 195 LICENSE #G74G 1-111 LICENSE # 52G59-ME ACCESS ROOF ��pF NE4yy ACCESS ROOF N� 1 13 q3 w FSS►ONP� 18'FlRE SETBACK @RIDGE 15-FIRE 5ET5ACr,@RIDGE PROJECT NAME DC O LU In O o w LU LU o in ~ g DL 1 7- 10" 20'- 1 n w z z O w O = ILL'— � p ? In O U m_ O N U SHEET NAME SITE PLAN ON5TRUCTION NOTES 1.)ALL EQUIPMENT 5HALL BE INSTALLED IN ACCORDANCE WITH THE DRAWING SCALE MANUFACTURER'S INSTALLATION INSTRUCTIONS. I /�j1I = 11_0I 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 8J 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.)THE BATTERY ENCLOSURE SHALL BE COMPLIANT WITH 2O20 NY5 FIRE CODE THE BATTERY ENCLO5UREMU5T ADHERE TO THE FIRE SAFETY 5TANDARD5 OUTLINED IN THE NEW YORK STATE FIRE CODE (NYS FIRE CODE R302). IT 15 IMPERATIVE THAT THE EXISTING GARAGE BE 5HEET NUMBER INSPECTED AND APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO ENSURE COMPLIANCE. PV-2 PLEASE BE ADVISED THAT WHILE WE ARE NOT CERTIFYING THE ENCLOSURE OURSELVES, IT IS UNDERSTOOD THAT IT MUST MEET THE AFOREMENTIONED FIRE CODE REGULATIONS. TAX MAP: 1 000- 1 04.00-04.00-0 1 4.000 Zoho Sign Document ID:2A768FFA-2MLDY-9101QJITZXYN5V4DIOTQNEIZIYTS7U QIGXIW LEGEND (�� DESIGN 6 DRAFTING BY: �BaSTNG UTILITY METER /V ELEMENT ENERGY LLC MAIN SERVICE PANEL oo REVIEW BY J.M.NABCEP CERTIFIE NEW PV SUB-PANELS 051112-129 A/C DISCONNECT I COMBINER INVERTERS (D GND ELECTRODE W27Q°Q REVISIONS PV MODULE 240 ®r, �9po^ DE5CRIF ON DATE REV o •7 C REV1510N 05-09-2024 5 RACKING RAIL 21 po 120° N A TYP. REV151ON 05-23-2024 C O ATTACHMENT POINT C 18po J0o REVISION 06-05-2024 0 ---RAFTERS PROOF PITCH ANGLE S NEW PV AC D15CONNECT REV1510N 12-18-2024 E B SUNRUN METER EW BE55 UNITS IN THE GARAGE FIRST FLOOR ®VENT EXISTING UTILITY15TING MAIN ELECTRICAL 5ERVICE PANEL IN BA5EMENT OPLUMBING VENT ®SKY LIGHT e CHMNEY CONTRACTOR ®ODMPOSTTE SHINGLESELEMENT ENERGY, LLC. GOOD CONDITION rf -1POTENTIAL SHADING ISSUES MATT 7CU SOUND VE , NY IA 95 f_ TRIM/REMOVE AS NECESSARY LICENSE # G74G 1-111 ACCESS ROOF LICENSE# 52G89-ME ACCE55 ROOF 2 I e•FIRE SETBACK�PoDGE 10340 ` I b'FlRE SETBACK @RIDGE AR SStONP�, PROJECT NAME 1 7- 1 0" 20'- I" � w Q Cc) O o Dc Dc a-/ 2 V PANEL TYP. w W tL 0 C O O U �0 O m 0 N U a_ TRING/CONNECTION TYP. 2'-7"— 0_ 2'-9" ARRAY#I A Y# 23 MODULES 13 MODULES 5HEET NAME 220 PITCH 22'PITCH [CPO-INVERTER TYP. CONSTRUCTION SUMMARY I G50 AZIMUTH I G50 AZIMUTH PV PLAN (3G) QCELL Q.PEAK DUO BILK ML-G 10+ 405 WATT PV MODULES (DIMENSIONS: 74"X 41.1"X 1.3") (3G) ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS (GO)ATTACHMENT POINTS @ G4"O.C. MAX. DRAWING 5CALE (249.G)LF IRONRIDGE XRI 00 MOUNTING SYSTEM. ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) II = 11_01 I /8 CONSTRUCTION NOTES 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 51-1EET NUMBER 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. PV-3 4.)WALLS AND CEILING INSIDE THE BATTERY ENCLOSURE SHALL BE ILMINATED WITH 515"TYPE X 5HEETROCK OR EQUIVALENT 5.)THE DOOR OF THE BATTERY ENCLOSURE SHALL BE 30 WIDE MINIUMUM 20 MINUTE FIRE RATED DOOR. TAX MAP: 1 000- 1 04.00-04.00-0 1 4.000 Zoho Sign Document ID:2A768FFA-2MLDY-910IQJITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW LOAD CALCULATION ARRAY#i ARRAY#2 ITEM DESCRIPTION AKRAY5#1-2 DESIGN i DRAFTING BY: RB Riciale Bear/Board 2"X 1 O"D. FIR ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 48.4 45.4 Rafter 2"X 8"D. FIR P I G"O.C. (D) Deckln 5/8"PLYWOOD REVIEW BY051 1 N2-129 cERnE ' #OF MODULES 23 13 Knee Walls 2"X G"D. FIR P I G"O.C. TOTAL MODULE WEIGHT(Lbs) 1 1 13.2 G29.2 J Ceiling Joist 2"X 8"D. FIR I G"O.C. REV15ION5 P TOTAL LENGTH OF L(Ft) 159.5 90.I Pitch 22° H Horizontal Span of 18 "MAX. DEscR�Pr1oN DATE REV RAIL REVISION 05-09-2024 B RAIL WEIGHT PER FOOT(Lbs) O.G8 0.68 REVISION 05-23-2024 C TOTAL RAIL WEIGHT(Lbs) 108.5 GI.3 REVISION 06-05-2024 D REV151ON 12-I&2024 E #OF STRANDOFFS 36 24 WEIGHT PER 5TRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 72 48 TOTAL ARRAY WEIGHT(Lbs) 1293.7 738.5 I POINT LOAD(Lbs) 35.9 30.8 CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 492.4 278.3 ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lbs15q Ft) 2,G 2.7 7470 SOUND AVE MATTITUCK, NY 1 195 GROUND WIND DESIGN SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE BARRIER AIR MEAN LICENSE#G74G 1-111 SNOW DESIGN DE51GN UNDER FLOOD LAYMENT y FREEZING ANNUAL LICENSE# 52G89-ME LOAD° Speed° Topographic Special Windborne CATEGORY' yyeathenng' Frost Termite` TEMP` REQUIRED" HAZARDS INDEXI TEMP (mph) effects unnd region debris zone'" dene EIV 20 140 NO NO NO B SEVERE 3 FT HEAVYO 15.F YES ZONE X 599 51'F j (�G�� N G/ YO �P O A MANUAL J DESIGN CRITERIA" Indoor Winter Summer w Elevation Latitude Altitude correction factor design Design temperature cooling Heating temperature heating cooling tempera difference 0) ture �O 703443 i 08 FT 4 1°N 1 5°F 8G°F 1.00 70°F 75°F 55°F AROSI'N' �S Wind Wind Coincident Winter _.Doling temperature difference velocity veloaty Daily range Summer humidity _ heating cooling wet bulb humidity PROJECT NAME ROOF FRAMING DETAIL �, 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GP @50%PH 0 For SI.1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. w Z Q � a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth I`_ Wp 0 _ strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as MODULE MOUNTING CLAMP to N O y- determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. ILI Z Z b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction SOLAR MODULE g N W shall fill in the frost line depth column with the minimum depth of footing below finish grade. C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. = ttu �U STAINLESS STEEL 3/8" d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined BOLT AND NUT t on a site-specific basis in accordance with Section R301.2.1.4. 0 n O = e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York U) I: i) H State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also 0 Q) — U see Figure R301.2(1).] f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. NRIDGE ALUMINUM RAIL 0 g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New ALUMINUM"L"BRACKFT York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: ALUMINUM FLASHING i.The accompanying Flood Insurance Rate Map(FIRM), 5HEET NAME ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. STRUCTURAL DETAILS h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ASPHALT SHINGLE ROOF effects of ice damming,the jurisdiction shall fill in this part of the table with"YES"Otherwise,the jurisdiction shall fill in this part of the table with"NO" 5/1 G"x G"STAINLESS i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WITH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" 2 1/2"MIN THREAD j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method PENETRATION SEALED (Base 32°F)." WITH GEOCEL 4500 DRAWING SCALE k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the (EQUIVALENT OR BETTER) jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (� 1. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with I�J "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. M. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the _N MStK jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at F /r—� _4 elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. I I I I �/ (') See Figure R301.2(4)B. MOUNTING DETAIL TAX MAP: 1000-104.00-04.00-014.000 Zoho Sign Document ID 2A768FFA-2MLDY-91010JITZXYN5V4DIOTQNEIZIYTS7U_QIGXIW CONSTRUCTION SUMMARY LEGEND DESIGN 6 DRAFTING BY: (2) UNITS OF SONNEN SONNENCORE+ 20 KWH BATTERY SEIOSTNG UTILITY METER ELEMENT ENERGY LLC MAIN SUB PANEL REVIEW BY J.M.NABCEP CERPF'F (DIMENSIONS: 27"X G9.5"X 14")IN ATTACHED GARAGE SDNFNCORE+10c'M BESS UNITS NEW PV SUB-PANELS 051 112-129 WITH REQUIRED FRONT CLEARANCE OF THIRTY-SIX INCHES A/C DISCONNECT Y—s• s'—s�• e' COMBINER INVERTERS GND ELECTRODE REV1510N5 CONSTRUCTION NOTES ON PV MODULE DESCRIPTION DATE pf, 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE ' RACI NG RAIL REVISION 05-09-2024 ~WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. R)_V1510N 05-23-2024 —� ,a• ,o• o ATTACHMENT PONT 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH REV1510N os-05-2024 D MINIMUM NEMA 3K RATING. ON srsrol snEs OF- ---RAFTERS REV151ON 12-18-2024 e 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE ` NM1S AND mNG PROOF PITCH ANGLE FIELD VERIFICATION. � BSUNRUN METER 4.)CONDUIT RUN/RACEWAY FOR BATTERY ENERGY - 5TORAGE SYSTEM (BESS)SHALL BE LOCATED WITHIN FIRE „• „ ®VENT RATED AREA. THE CONDUIT/WIRE RUNS TO THE EXISTING 2X4 I"�STUD O G VENT MAIN SERVICE PANEL AND TO THE PLP IN PVC CONDUIT ®SKY LIGHT INSIDE OF THE EXISTING BA5EMENT AND THEY SHALL BECHIMNEY CONTRACTOR LOCATED INDOORS. \�� ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. 5.)THI5 BE55 SYSTEM 15 COMPLIANT WITH THE SECTION ` ®GOOD CONDITION 7470 SOUND AVE R327 OF THE INTERNATIONAL RESIDENTIAL CODE, AS —TRIM/REMOVE POTENTIAL SHADING A ISSUES AR MATTITUCK, NY 1195 AMENDED BY THE NEW YORK STATE UNIFORM CODE. e. LICENSE#G74G I 5 G.)THE BATTERY LOCATION MUST ADHERE TO THE FIRE HI SAFETY STANDARDS OUTLINED IN THE NEW YORK STATE LICENSE# 52G89-ME FIRE CODE(NY5 FIRE CODE R302). IT 15 IMPERATIVE THAT THE AREA WHERE BESS IS LOCATED BE INSPECTED AND pF NEW APPROVED BY THE DESIGNATED FIRE CODE ENFORCER TO �� ENSURE COMPLIANCE. PLEASE BE ADVISED THAT WHILE �P Ito A WE ARE NOT CERTIFYING THE ENCLOSURE OURSELVES, IT c� 15 UNDERSTOOD THAT IT MUST MEET THE AFOREMENTIONED FIRE CODE REGULATIONS. �0344$ (� sso ' ._��. PROJECT NAME OW In ILJ Z Q Q� \XIrTIN.GARAGE WALL Y w O LLJ Z Z O LU ILJ o LU ? � O - U) _ U m_ F- O N U DC D_ a SHEET NAME BATTERY PLAN DRAWING SCALE 1-01 [GARAGE PLAN] Pv-5 TAX MAP: 1000- 104.00-04.00-01 4.000