About
50571-Z
hoy�dof solo/ c Town of Southold * * P.O. Box 1179 io 53095 Main Rd eou►m. Southold, New York 11971 I CERTIFICATE OF OCCUPANCY No: 46030 Date: 03/12/2025, THIS CERTIFIES that the building GENERATOR Location of Property: 1000 Village Ln Orient, NY 11957 Sec/Block/Lot: 25.4-18 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 02/26/2024 Pursuant to which Building Permit No. 50571 and dated: 04/22/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory generator as applied for. Maintain 36 inch clearances on all sides of generator from shrubs and 60 inch clearance above generator. The certificate is issued to: JOTAS Corp Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50571 07/23/2024 PLUMBERS CERTIFICATION: - I uth iz d S gnature �o�suFFoc�.�o TOWN OF SOUTHOLD �y BUILDING DEPARTMENT TOWN CLERK'S .OFFICE �y • �� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50571 Date: 4/22/2024 Permission is hereby granted to: JOTAS Corp 25500-Main Rd J Orient, NY 11957 To: install generator in rear of building as applied for. At premises located at: 1000 Village Ln, Orient SCTM #473889 Sec/Block/Lot#25.-1-18 Pursuant to application dated 2/26/2024 and approved by the Building Inspector. To expire on 10/22/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector rjF S0�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �o sean.devlinl'a-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: JOTAS Corp Address: 1000 Village Ln city:Orient st: NY zip: 11957 Building Permit#: 50571 Section: 25 Block: 1 Lot: 18 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician:.CuStom Lighting of Suffolk License No: 38893ME SITE DETAILS . Office Use Only Residential Indoor Basement Service Commerical X Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 26kW Kohler Generator w/ (3) Transfer Switches -(2)100A Transfers &(1)150A 125A Sub Panel 12 Circuit/6 Used Notes: Generator Inspector Signature: f Date: July 23, 2024 S.Devlin-Cert Electrical Compliance Form. FS0tat" o s7c)5-7 # TOWN OF SOUTHOLD BUILDING 136 . coum, 631-765-1802 1 N SPECT-10N. - - - [ ]- FOUNDATION 1 ST/ REBAR j ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [' ] FIREPLACE &CHIMNEY [ : ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]- FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR ISO - --- * TOWN OF_SOUTHOLD BUILDING, DEPT. 631-765-1802 INS PECT-1-0 N - - [ ]. FOUNDATION 1 ST/ REBAR . [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] NSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL &Wm4f%'� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [" .] FIRERESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE 'Y -.INSPECTOR t. `'' fir ,Z •,:'w+'. -'� -- _ t1 r ` f• �- } T A ' yI • _ r 4 41, -44 is 4 #'•���•Y r xt e•, �' � iti��a �•� 1••t . 114•i ECEIUE .� � z r � r, 410 1' dr a,. • + � � i � � , '�f yea i � � 1�. a � r� � ��' �• 4. Jf t� • t• w 4 { EMI$ouT{y_ TU Wt4 OF SOUTNOLD BUILDING DEPT. 631�-765-1802 If4SPECTION ROUGH PLBG. t FOUNDATION 1ST /REBAR [ INSULATION/CAULKING L FOUNDATION 2ND FINAL I FRAMING 1 STRAPPING [ , FIRE SAFETY INSPECTION ] FIREPLACE &CHIMNEY ON [ � FIRE RESISTANT PENETRaTIQ � FIRE RESISTANT CONSTRUC?I [ � ELECTRICAL[(jlRl_NTAL � ELEC TRICAL(ROUGH) [ PRE CIO t CODE VIOLATION _ --- -- J U L 2 �- die t 1� n of SauthOtd FOR .,e 4. '. 5 w J'� 'f / •r \ r •F* - � .. . � � -` `']' F � _III _I � _� •♦, ....�.• f - Mom..; t ,�+. �- a. }� x�Y` -yE�-_ .'�?. ' _ •alp`,'Y rid •IA T4 r' I� j ^t "�� � .• µ"s 7 wy i" y «� 1 i I. r <r . ..- � ��'� r:.{•� '}� �' Via,. 3^-�'�, t �'':' •�'.'�'r`�• �VLSI�,'�,a•� .� �;��f� ,� i' '.'a.`•,�`h ti � Kf 1r�1:`bn ed� ,`,.` L�_i 7"Ty��^Frr,.rt�Y � ,R,�j� p F,t, • I � -�ti_1 � i r✓�� � K - -tr.R, .ice~ 'w k. �Il :e •• :. :fir«. � � \ • �, � a= � a� k FIELD INSPECTION REPORT DATE COMMENTS , FOUNDATION(1ST) ------------------------------- rA ----- � C FOUNDATION (2ND) " O Cd a ROUGH FRAMING& lam] PLUMBING c� CU INSULATION PER N.Y. cam- y STATE ENERGY CODE v or v FINAL Li ADDITIONAL COMMENTS r- /b 7;?1 - -- I O 7 ,- F2# * 110114 EI V, �, m S of -� � ro y O y� t" y x e b H Wtt�o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�0! Telephone (631) 765-1802 Fax(631)765-9502.httpst//www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERti IT For Office Use Only65_1 4 ®s' PERMIT NO. Building Inspector: F F R 2 6 2024 ?{Z+ ✓� ����m Ill����"�,�� ;�i�,2�``�`' s/'�✓���I✓!r/✓t���,�✓T��`F� `�'��4��+''��t,�,.a. ����J� r�,rf��E' ..�' MApplications and forms✓must be filled out in theirentiret Incom late applications will'not be accepted Where the Applicant is not the owner,an ec[tF �)y� z_>, �f .Owner's Authorization form(Page 2)shall be completed _ ' f 1't.,yv;g of Southold mod,'� �f, �`a. rH,w`.;'4n✓,.'`,Rk; Mzt4 v,X �,,, ,.�cr E4+'rr,.�., `.°n,,� „v,"✓.{r: /:., Date: 9- 2 wi, tea. Name SCTM 1000 S :# . ... .: ._ gq.a .w._. .,. ...... Project Address: p p Phone#: a Q_ p2 a Q (, `3 �—+ Email 50 S er•p fo/o Mailing Address {ix r ." .., r.� S�,az ,f.�S'4%'''. ' J•. F . Ir11 v rriXx'�4�` 4',.'4 ns.-`,irJ�` �t !✓ F':H'�, P *�s...,;.. n IFr tali 3 ir.Y`�✓ X`"„"- -h,'f"" of l ;CONTACT PERSON X� � � 5 zf �r,r� s✓ ray ,✓� y ✓r �I� ✓fA't .. ,✓ Name: Mailing Address: ice► ( `� Phone# � �j[2^d(o a--- Email: ��.� .,.Y :�.�r ,. a-.,:. _3�'�+ x`'y'x •"r Yoh r�',,rb y�r��� �.M e t�r��7F i"�� ��✓�' r1 ,DESIGN PROFESSIONAL INFORMATION ¢{, � r iGx!x;c x„ ,`_ s�1*4 �� ,. �R A ,✓.x._ .. ..,�. .... . , Name: Mailing Address: Phone#: Email: e ✓s a'my.,�"1 ,� Jj c,.�' a. F �'tfl.�v � 3`iy ,,.,� '�,�� ��,, n✓' � ��3 ;CONTRACTOR INFORMATION � t� � � " � �'; .�..,,,,rz v,r, ✓�_. �„ ..,��.✓ .�� xran�� ;:,'(��' 3�t..,��,,•��t`3 t�" r.�'q�„A . rPr-�.a'L�.:a.�an �`��,. i!„E���,�ff��f�f�+�'��� �.;aw ^��. Name: Mailing Address: Q C ., Phone# �` VS Email:CLASS V) ' a a.. F'�P Y L'q"�., -p,y 1DESCRIPTION OF PROPOSEDiCONSTRUCTION � lr ` x .,#��cX �,�„ �4 ��`t�tr �✓ .G:G ++Ir k✓'7 f"f �' �tk-.. nr�.�5✓r y El New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes ❑No 1 '.,' 3, `� 'Q a'PROPERTY`INFOR MAT 10N` Zr�,,,.,� - r.,.�,r„s•. r -..,-r .•.".�,n._Z.x£' n..1,. t.�m.^- ..,._..��A� ,..."f. tFti^�,_�',,.. ,.X......cwr,.r. .o-.�P�..._.�?.';.:"!G"a.'"".�`,�.tN a." �.; ,, r .-�°��,,.,..�. Existing use of property. Intended use of property. .M .. t . ,V ..; .uoe� w _. �.n....___ . Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes 2fio IF YES,PROVIDE A COPY. .,'age���e..-,;•t fnm d`,,,� +: rm'provided Check Box After Reading The owner/contractor/desig''n'profes's"tonal is responsible for all tlrain and storm water,issues as,;' „by -`Chapter 236 of the Town Code APPLICATION IS$HEREBY MADE to the Bullding.Department for the issuancetof a Budding Permit pursuant to the Bwldmg Zone Ortlmance of the Town of Southold Suffolk,County Newyork and other ap "ter plicable Laws Ordinances or Regulations;fo'r the constructionof buildings rr ?additions;aerations or for removalkorrtlemohtion as hereiri'tlescnbedThe applicant agrees to comply withtall applicable laws ordmancesbwldmgcode, b`n� r� r f%3 _ -Ga / ;3'; '� v „ s.y;3 r r >c. 5 *�"r{ >ri� �rzr",.H,rr•4ar 4 ri a ar i r,+."2 t-Ca housing;code and regulations-and to atlmtt authorized inspectors on"premises and Inbwldmg(s)fornecessary Inspections False tatements.made lierein are pumsha6 as a class A misdemeanor pursuant to;Sectlon 210 45 ofahe New York State Penal Law x� F *n x s Yy Application Submitted By(print na p ElAuthorized Agent Zbwner er Signature of Applicant Date: CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York No.01 BU6185050 SS: Qualified In Suffolk County, COUNTY OF ) Commission Expires April 14,2a y being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day D nQ V day of J�'�CJ r Z/1 20 ( L �V J Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) f� l� I, d�`L ����� residing at i do hereby authorize + • to apply on UP my behalf t n of Southold Building Department for approval as described herein. Owner's Signature Date �pq Vl lc7 �L�O �¢gS Print Owner's Name 2 Ew BUILDING DEPARTMENT-Electric I fspe F E B 2 7 2024 . TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road - PO Box 1179 " New York 11971-095�$`lid° ��rxent �►- Southold, ° • r - '� , Telephone (631) 765-1802 - FAX(631) 769`-J�vtY7'�'�� �'�' ;< ro4errl�southoldtownny.gov seandCa�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Custom Lighting of Suffolk Inc Electrician's Name: Benjamin Doroski License No.: 38893-ME Elec. email:CLOS5170@gmail.com Elec. Phone No: 631-298-4588 01 request an email copy of Certificate of Compliance Elec.Address.: PO Box 1698 Mattituck NY 11952 JOB SITE INFORMATION (All Information Required) Name• (o( P Address: 1 L7 O 1 l Cross Street: Phone No.: Bldg.Permit#: a C5,� email: C'.l CSn I 0 �V) J , Tax Map District: 1000 Section: Block: Lo : BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): o� 60 Gowck+a V_ 6L Square Footage: Circle All That Apply: Is job ready for inspection?: YES©NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES�NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[—]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? MY ON Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT-Electrical Ifispector FEB 2 7 TOWN OF SOUTHOLD n24 Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11 971-09591-"*`'-� Telephone (631) 765-1802 - FAX (631) 76' - seand(cD-southoldtownny.gov rogerr(&-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION"wi inforrnation Required) Date: Company Name: Custom Lighting of Suffolk Inc Electrician's Name: Benjamin Doroski License No.: 38893-ME Elec. email:CLOS5170@gmall.com Elec. Phone No: 631-298-4588 211 request an email copy of Certificate of Compliance Elec. Address.: PO Box 1698 Mattituck NY 11952 JOB SITE INFORMATION (All Information Required) Address: 1G)nL !Vjljck �e ( aj-i-e LT -rij— Ou Cross Street: Phone No.: c' Bldg.Permit#: 5-0 5-7 t email: 0 1 cE:sr-) 1-7() or-,Own o, 1 Tax Map District: 1000 Section: Block: L ol: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): lGo GOUY-01+6 V1-, 61, �s I Square Footage: Circle All That Apply: N9 0 Is job ready for inspection?: YES ®NO Rough In Final Do you need a Temp Certificate?: El YES �NO Issued On Temp Information: (All information required) Service SizeF-11 Ph F]3 Ph Size: A # Meters Old Meter# New ServiceE]Fire ReconnectE]Flood ReconnectElService Reconnect[:]UndergroundE]Overhead # Underground Laterals[]1 FJ2 [] H Frame [-] Pole Work done on Service? DY F1N Additional Information: PAYMENT DUE WITH APPLICATION L111-11 konelxs PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator�,� Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV Inst Hot DeHum Transfer j$�� HOT TUB/SPA Disc f OD Blower Combo Cooktop Minisplit AC AH Hood Blower Service Amps Have Used Sub 1 � Have Amps Used 2-- Comments l-ZO a a Fuentes, Kim From: McGivney,Julie Sent: Monday, April 22, 2024 8:06 AM To: Fuentes, Kim;Alan Wexler;Anne Surchin;Jeri Woodhouse; Marina DeConciliis Cc: Nunemaker,Amanda Subject: RE: HPC -JOTAS, 1000 Village Lane - Generator PRIVILEGED&CONFIDENTIAL-ATTORNEY-CLIENT COMMUNICATION/ATTORNEY WORK PRODUCT-INTER-OFFICE/INTRA-AGENCY COMMUNICATION-NOT SUBJECT TO FOIL DISCLOSURE/NOT FOR DISTRIBUTION The generator is not under the purview of the HPC. Thanks, Julie JULIE M. Mc4IVNEY Assistant Town Attorney Town of Southold Town Hall Annex 54375 Route 25 P.O. Box 1179 Southold, New York 11971 631-765-1939 631-765-6639 JuliemAsoutholdtownny.gov CONFIDENTIALITY NOTICE:This electronic mail transmission is intended only for the use of the individual or entity to which it is addressed and may contain confidential information belonging to the sender which is protected by the attorney-client privilege. If you are not the intended recipient,you are hereby notified that any disclosure, copying, distribution, or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this transmission in error, please notify the sender immediately by e-mail and delete the original message. ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. From: Fuentes, Kim <kim.fuentes@town.southold.ny.us> Sent: Friday,April 19, 2024 4:05 PM To: McGivney,Julie<juliem@southoldtownny.gov>;Alan Wexler<awexlerstudio@gmail.com>; Anne Surchin <surchin@mac.com>;Jeri Woodhouse<Jeriwood house @gmail.com>; Marina DeConciliis<marina@mkarchitect.com> Cc: Nunemaker,Amanda <Amanda.Nunemaker@town.southold.ny.us> Subject: HPC-JOTAS, 1000 Village Lane-Generator i N Hi, The Permits Examiner, Amanda, is asking if a generator in the rear yard requires HPC approval, as shown attached. I'm hoping we can go with "no" since the generator will not be seen from Village Lane. Please respond, so that the Building Dept. can issue a building permit. Thank you. Kim E. Fuentes Board Assistant Zoning Board of Appeals Coordinator, Historic Preservation Commission 631-765-1809 kim a southoldtownny.gov Location: 54375 Main Road Mail:P.O. Box 1179 Southold, NY 11971 2 S Fuentes, Kim From: Allan Wexler <awexlerstudio@gmail.com> Sent: Friday,April 19, 2024 5:07 PM To: Fuentes, Kim Cc: McGivney,Julie;Anne Surchin;Jeri Woodhouse; Marina DeConciliis; Nunemaker, Amanda Subject: Re: HPC -JOTAS, 1000 Village Lane - Generator it seems if the generator can not be seen from a public right of way it would not need our approval. Is this correct? On Fri,Apr 19,2024 at 4:05 PM Fuentes, Kim <kim.fuentes@town.southold.ny.us>wrote: Hi, The Permits Examiner, Amanda, is asking if a generator in the rear yard requires HPC approval, as shown attached. I'm hoping we can go with "no" since the generator will not be seen from Village Lane. I Please respond, so that the Building Dept. can issue a building permit. Thank you. Kim E. Fuentes Board Assistant Zoning Board of Appeals Coordinator, Historic Preservation Commission 631-765-1809 kim outholdtownn ov 1 Location: 54375 Main Road I I Mail:P.O. Box 1179 Southold, NY 11971 a Allan Wexler www.aIlanwexlerstudio.com https://www.amazon.com/Alla n-Wexler-Absurd-Thinking-Between-Design/dp/3037785160 https://en.wikipedia.org/wiki/Allan Wexler https://www.instagram.com/aIlanwexlerstudio/ 87 Smith Street-10D Brooklyn, NY 11201 10900 North Bayview Road Southold, NY 11971 2 Fuentes, Kim From: Anne Surchin <surchin@mac.com> Sent: Friday, April 19, 2024 6:12 PM To: Wexler Allan Cc: Fuentes, Kim; McGivney,Julie;Jeri Woodhouse; De Conciliis Marina; Nunemaker, Amanda Subject: Re: HPC-JOTAS, 1000 Village Lane - Generator Kim, Can you confirm that the location of the generator behind the house is noted with a circle and an "x" hatch in it and highlighted in orange?It is not labeled as a generator. If the notation represents the generator location then we would not be able to see it from the street. -Anne Anne Surchin Architect P.O.Box 1201 Southold,New York 11971 surchin@mac.com 631-765-6364 866-370-3806(fax) ------------------------------------------------------------------------------------------------------------------------ ------------------------------------------------------------- This email message,including any attachments,is for the sole use of the intended recipient(s) and may contain information that is proprietary,confidential,and exempt from disclosure under applicable law.Any unauthorized review,use,disclosure,or distribution is prohibited.If you have received this email in error please notify the sender by return email and delete the original message.Please note,the recipient should check this email and any attachments for the presence of viruses.This office accepts no liability for any damage caused by any virus transmitted by this email. 1 On Apr 19, 2024,at 5:06 PM, Allan Wexler<awexlerstudio@email.com>wrote: it seems if the generator can not be seen from a public right of way it would not need our approval. Is this correct? On Fri,Apr 19, 2024 at 4:05 PM Fuentes, Kim <kim.fuentes town.southold.ny.us>wrote: Hi, The Permits Examiner, Amanda, is asking if a generator in the rear yard requires HPC approval, as shown attached. I'm hoping we can go with "no" since the generator will not be seen from Village Lane. Please respond, so that the Building Dept. can issue a building permit. Thank you. Kim E. Fuentes Board Assistant Zoning Board of Appeals Coordinator, Historic Preservation Commission 631-765-1809 2 kim,&southoldtownny.gov Location: 54375 Main Road Mail:P.O. Box 1179 Southold, ATY 11971 Allan Wexler www.aIlanwexlerstudio.com https•//www.amazon.com/Allan-Wexler-Absurd-Thinking-Between-Design/dp/3037785160 https://en.wikipedia.org/wiki/Allan Wexler https:Hwww.instagram.com/aIlanwexlerstudio/ 87 Smith Street- 10D Brooklyn, NY 11201 10900 North Bayview Road Southold, NY 11971 3 Fuentes, Kim From: Jeri Woodhouse <jeriwoodhouse@gmail.com> Sent: Saturday, April 20, 2024 8:00 AM To: Fuentes, Kim Subject: Re: HPC -JOTAS, 1000 Village Lane - Generator I opt for no Jeri Woodhouse On Fri,Apr 19, 2024 at 4:05 PM Fuentes, Kim<kim.fuentes@town.southold.ny.us>wrote: Hi, The Permits Examiner, Amanda, is asking if a generator in the rear yard requires HPC approval, as shown attached. I'm hoping we can go with "no" since the generator will not be seen from Village Lane. Please respond, so that the Building Dept. can issue a building permit. Thank you. Kim E. Fuentes Board Assistant Zoning Board of Appeals Coordinator, Historic Preservation Commission 631-765-1809 kim&southoldtownnygov 1 ' 'Location: 54375 Main Road I� Mail.P.O. Box 1179 I Southold, NY 11971 1 z Fuentes, Kim From: Patricia C. Moore <pcmoore@mooreattys.com> Sent: Saturday, April 20, 2024 10:07 AM To: Fuentes, Kim Cc: Betsy Perkins; Sakarellos, Elizabeth;Westermann, Donna; Kylee DeFrese; Nick Feihel; Roland M Grant Subject: Re:ZBA Roland Grant- 800 Horton Lane -#7847 Hi Kim- I asked the architect regarding the loading dock-he says"it is recessed into the ground to allow a truck to back into it and have the loading area.be flush with grade......so the loading is into the 1st floor, not basement....Can you ask Mike Verity regarding this design. The design would indicate that the driveway slopes partly below grade but it is not an access into the lower level (basement). Thank you Pat Patricia C. Moore, Esq. PLEASE,BE SURE TO COPY MY ASSISTANTS' betsv@mooreattvs.com,and kvlee@mooreattvs.com -------------------------- Mailing & Physical Address: Moore Law Offices 51020 Main Road William D. Moore, Esq. Southold NY 11971 631.765.4663 Fax Number: Patricia C. Moore, Esq. 631.765.4643 631.765.4330 www.mooreattys.com On Fri,Apr 19,2024 at 3:39 PM Fuentes, Kim<kim.fuentes@town.southo Id.ny.us>wrote: j Hi Pat and Betsy, I'm preparing for a copy of the amended plans that you submitted earlier today to be forwarded to the Planning Department for updated comments. You may recall that during the public hearing of the ZBA, the Board discussed whether the loading dock is a structure, and whether a rear yard setback variance will be required. i In speaking Mike V., if the loading dock is not on grade, then it is a structure. Plans depicting the elevation,and setbacks of loading structure should be submitted to the Building Dept. and the ZBA, and the NOD may need to be amended. Thank you. 1 i Kim E. Fuentes Board Assistant { Zoning Board of Appeals Coordinator, Historic Preservation Commission 631-765-1809 1 kim&southoldtownny.Qov Location: 54375 Main Road Mail:P.D. Box 1179 j Southold, NY 11971 I From: Betsy Perkins<betsv@ moo reattys.com> Sent: Friday,April 19, 2024 2:54 PM To: Fuentes, Kim<kim.fuentes@town.southold.ny.us> Cc: KYLEE DEFRESE<kylee@mooreattys.com> Subject:grant; 800 hortons lane I hi Kim. Per our request, lease see attached. � Y q p I 2 Betsy Perkins, Paralegal PLEASE.REPLY TO ALL --------------------------- Mailing & Physical Address: Moore Law Offices 51020 Main Road William D. Moore, Esq. Southold NY 11971 631.765.4663 Fax Number: Patricia C. Moore, Esq. 631.765.4643 631.765.4330 www.mooreattys.com ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 3 V L P DRIrANNE BENNER KEVIN PERRY r WELL O OO WELL �O WELL LAND N/F OF GRAYSON MURPHY r 1 125.90' P�p6 S 64023'20"E 2N SPLIT RAIL FENCE 6� EL 14.0 EL 14.3 EL 115.2 EL 16.2 V 1 O �\ O BLUE STONE DRIVEWAY o if m 00W U O ao 38.6' e 3 / EL 13.7 �pE cl P,I L.P. o 24.4' 0 OR�J 0 POST ON .X LAND N/F OF = OFFICE WELL KENT MCCARTHY z I STORY v N w FRAME i Rp55 i GARGF AGE Z EL 15. 0 1 STORY Z0^ 0 0 o MULTI-US FFL E W U 3 FRAME BLDG. .i ON �2.8' 29.9". 17.8 OR�G'F O ox- RETAIL o �i ow v SPACE ¢ u1 30 CON N a? 13.7' o ,� 47.2' 30.4' 24.4' Co N U PATIO C P WI g 9.7' y u CONC. DqN 90, EL 13.3 _ 6 O !�O N 64023'20"W � 125.42' �? WELL O WELL p LAND N/F OF ANDREW K COLLIER 0 N L.P. WELL SKIPPERS (50') LANE (STATE STREET) •f� i APPROVED AS NOTED DATE• .R# 565 FEE NOTIFY BUILDING DEPARTMENT AT 631-765.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 1 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND COND TIONS OF SOUTHOLD TO ZBA SOUTHOLD T WN PLANNING BOARD SOUTHO OWN TRUSTEES N.Y.&D SO LD HPC SCH OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAI OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED KOHL,ER. Models: 26RCA(L) Multi-Fuel LPG/Natural Gas 09001 Standard Features KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and " dry ' transfer switch functions(with optional Model RXT). o Electronic speed control responds quickly to varying demand. o OnCueG Plus Generator Management System for remote monitoring is included with the generator. • Kohler Command PRO Engine Features o Kohler Command FROG OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. Designed for Easy Installation The Kohler® Advantage o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. • High Duality Power o Fuel and electrical connections through the enclosure wall Kohler home generators provide advanced voltage and eliminate the need for stub-ups through the base. frequency regulation along with ultra-low levels of harmonic o Customer connection terminal block located near the distortion for excellent generator power quality to protect your controller allows easy access for field wiring. valuable electronics. o Designed for outdoor installation only. • Premium 5-yr/2000-hr Limited Warranty Included o Approved for stationary standby applications in locations Kohler is known for extraordinary reliability and performance. served by a reliable utility source (on-grid). Kohler's premium limited warranty covers parts,labor,and travel for the full warranty period. • Certifications • Powerful Performance o Meets emission regulations for U.S.Environmental Exclusive Powermanc technology provides excellent Protection Agency (EPA) with both natural gas and LPG. starting power.§ o UL 2200/cUL listed. o Accepted by the Massachusetts Board of Registration of • Aluminum Enclosure Plumbers and Gas Fitters. o Attractive aluminum enclosure allows installation as close o Meets 181 mph wind rating. as 18 inches from your home or small business.t • Exercise Modes o Enclosure panels can be removed without tools to allow o 90-second EcoExercise, unloaded,with system easy access for maintenance and service. diagnostics. Reduces fuel costs and minimizes sound • Camouflage Enclosures are available for single-phase units disruption. (optional). Go to KohlerGenerators.com/MossyOak to view o Unloaded weekly exercise with complete system the available patterns. diagnostics(20 minutes) Mossy Oak is a trademark used under license from Haas Outdoors,Inc.,by Kohler Co. o Unloaded full-speed exercise(20 minutes) o Loaded full-speed exercise(20 minutes;Model RXT ATS required) o Weekly,bi-weekly,or new monthly exercise intervals. • Model 26RCAL includes a model RXT automatic transfer switch.See last page for more details. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Model Alt Voltage Ph Hz kW/kVA Amps kW/kVA Amps Amps Poles 26RCA 2F8 120/240 1 60 24/24 100 26/26 109 125 2 26RCAL 120/208 3 60 22/27 77 22/27 77 80 3 26RCA 2138 120/240 3 60 22/27 67 22/27 67 80 3 277/480 3 60 22/27 34 22/27 34 40 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All single-phase units are rated at 1.0 power factor.The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES INES FOR DERATING:ALTITUDE:Derate 4%per 305 m(1000 ft)elevation above 153 m(500 ft.).TEMPERATURE:Derate 2%per 5.5°C(101 F)temperature increase above 1 VC(601 F). Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator dealer for availability. ' § Check the appliance manufacturer's specifications for actual power requirements. Consult a KohlerO Power Systems professional to calculate your exact residential power system requirements. t Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. G4-315 (26RCA) 4/23a Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator . Compliance with NEMA,IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field . Self-ventilated and dripproof construction. Leads,quantity 2F8 4 • Windings are vacuum-impregnated with epoxy varnish for 2G8 12 dependability and long life. Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H a Digital voltage regulator with±1.0%no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed • Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full • Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load RMS ±1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V,1 ph 2F8(4 lead) 39(60 Hz) 240 or 480 V,3 ph 2G8(12 lead) 63(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH1006 4-Cycle enclosure at rated kW,dry,°C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,Cm3(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Type Compression ratio 10.5:1 Type Full Pressure Main bearings:quantity,type 2, Heavy-Duty Sleeve Oil capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM 3600 Oil cooler Integral Max.engine power at rated rpm,kW(HP) § Kohler recommends the use of Kohler Genuine oil and filters. LPG 26.1 (36.4) Fuel Requirements Natural gas 24.5(33.0) Fuel System Cylinder head material Aluminum Valve material Steel/Stellite® Fuel types Natural Gas or LPG Fuel supply inlet 3/4 NPT Piston type and material Aluminum Alloy Fuel supply pressure,kPa(in.H2O): Crankshaft material Heat Treated,Ductile Iron Natural gas 0.9-2.7(3.5-11) Governor:type Electronic LP 1.7-2.7(7-11) Frequency regulation,no load to full load Isochronous Frequency regulation,steady state -0.5/a Fuel Composition Limits* Nat Gas LPG Air cleaner type Dry Methane,%by volume(minimum) 90 min. — Ethane,%by volume(maximum) 4.0 max. Engine Electrical Propane,%by volume 1.0 max. 85 min. Engine Electrical System Propene,%by volume(maximum) 0.1 max. 5.0 max. Ignition system Electronic, C4 and higher,%by volume 0.3 max. 2.5 max. Capacitive Discharge Sulfur,ppm mass(maximum) 25 max. Starter motor rated voltage(DC) 12 Lowe3(Btu/q value, MJ/m Btu/ft ),(minimum) 33.2(890) 84.2(2260) Battery(purchased separately): * Contact your local dealer for suitability and rating derates based on Ground Negative fuel compositions outside these limits. Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA)rating for-18°C(0°F) 500 Group size 51 G4-315 (26RCA) 4/23a Fuel Pipe Size Operation Requirements Minimum Gas Pipe Size Recommendation,in.NPT Fuel.Consumption,m3/hr.(cfh)@ 60Hz Pipe Length, Natural Gas LPG %Load Natural Gas LPG m(ft.) 290,000 Btu/hr. 322,500 Btu/hr. 100 B.2 (290) 3Z (129) 8 (25) 1 3/4 75 6.7 (238) 3.1 (111) 15 (50) 11/4 1 50 5.1 (180) 2.4 (85) 30 (100) 1 1/4 1 25 3.9 (137) 1.8 (64) 46 (150) 1 1/4 1 Exercise 1.9 (67) 0.9 (31) 61 150 1 1/4 1 1/4 Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) ( ) LPG: 93 MJ/m (2500 Btu/ft. ) Generator Set Sound Data LPG conversion factors: 0.535 m3 11 kg Model 26RCA sound levels are 56 dB(A) during engine exercise 36.39 ft.3 =1 gal. and 67 dB(A)during full-speed generator diagnostics and normal operation.* All sound levels are measured at 7 meters with no load. * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation parameters. RDC2 Controller Features • Exercise modes: o New 90-second Eco Exercise with complete system diagnostics (factory default setting) Voltage: 2407V o Lowers fuel cost Freq: 60.0 Hz o o Minimizes sound disruption dog o o O q In cold temperatures,limits condensation build-up in 1 0 0 0 the crankcase o Unloaded weekly 20-minute exercise with complete —a system diagnostics o Unloaded 20-minute full-speed exercise o Loaded 20-minute full-speed exercise(Model RXT ATS The RDC2 controller provides integrated control for the required) generator set, Kohler®Model RXT transfer switch, • Weekly, bi-weekly,or new monthly exercise intervals programmable interface module(PIM), and load shed kit. • Front-access mini USB connector for SiteTech- or USB • Membrane keypad: Utility connection o OFF,AUTO,and RUN pushbuttons • Integral Ethernet connector for KohlerO OnCueO Plus o Select and arrow buttons for access to system • Remote two-wire start/stop capability for optional connection configuration and adjustment menus of a Model RDT transfer switch • LED indicators for OFF,AUTO, and RUN modes • Diagnostic messages: Displays diagnostic messages for the • LED indicators for utility power and generator set source engine,generator,Model RXT transfer switch,programmable availability and ATS position (Model RXT transfer switch interface module(PIM),and load management device. required) • Maintenance reminders • LCD display: • System settings: o Two lines x 16 characters per line o System voltage,frequency,and phase o Backlit display with adjustable contrast for excellent o Voltage adjustment visibility in all lighting conditions o Measurement system, English or metric • Scrolling system status display: • ATS status (Model RXT ATS required): o Generator set status o Source availability o Voltage and frequency o ATS position (normal/utility or emergency/generator) o Engine temperature o Source voltage and frequency o Oil pressure • ATS control (Model RXT ATS required): o Battery voltage o Source voltage and frequency settings o Engine runtime hours o Engine start time delay • Date and time displays o Transfer time delays • Smart engine cooldown senses engine temperature o Voltage calibration • Digital isochronous governor maintains steady-state speed at o Fixed pickup and dropout settings all loads • Programmable Interface Module(PIM) status displays: • Digital voltage regulation: ±1.0% RMS no-load to full-load o Input status (active/inactive) • Automatic start with programmed cranking cycle o Output status (active/inactive) • Built-in 2.5 amp battery charger • Load control menus: • Programmable exerciser can be set to start automatically on o Load status any future day and time o Test function G4-315 (26RCA) 4/23a KOHL K�HLER® Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Literature • Aluminum sound enclosure ❑ General maintenance literature kit • Battery cables ❑ Overhaul literature kit • Critical silencer ❑ Production literature kit • EPA certified fuel system Maintenance • Field-connection terminal block ❑ Maintenance kit(includes air filter,oil,oil filter, and • Fuel solenoid valve and secondary regulator spark plugs) ❑ Premium 300 hour/2 year oil for fewer oil changes • Line circuit breaker • Multi-fuel system, LPG/natural gas,field-convertible 26RCAL Model Package • Oil drain extension with shutoff valve ❑ 26RCAL with 200 amp service entrance-rated Model RXT • Oil level sensor with combined interface/load management board and corrosion-resistant NEMA3R aluminum enclosure • Oil pressure sensor Warranty • OnCue®Plus Generator Management System ❑ 7-Year Limited Warranty • Premium 5-year/2000 hour limited standby warranty. ❑ 10-Year Limited Warranty Covers parts,labor,and travel for the entire warranty period Warranties cover parts,labor,and travel for the entire • RDC2 generator set/ATS controller warranty period. • Rodent-resistant construction • Sound-deadening,flame-retardant foam per LIL 94, class HF-1 Available Options Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120 VAC ❑ Carburetor heater, 120 VAC t Generator Set Dimensions and Weights ❑ Cold weather kit, 120 VAC t o Includes fuel regulator heater,oil and breather tube heaters. Generator Set Size,L x W x H: 1193 x 6 x mm .3 (47 x 26.0 0 x 32.3 in.) o QS model with factory-installed kit is available. Emergency Shipping Weights: enc ❑ 9 Y stop kit 26RCA Generator Set: 283 kg(625 lb.) ❑ Programmable interface module(PIM) 26RCAL with 200 A RXT SE ATS: 304 kg(670 lb.) (provides 2 digital inputs and 6 relay outputs) * Battery heater is recommended below-17°C(0°F). -{ r L Do not use a carburetor heater with a cold weather kit. I t Cold weather kit is recommended below 0°C(32°F). Enclosure Options(single-phase only) ❑ Mossy Oak@ camouflage enclosures available. H Go to KohlerGenerators.com/MossyOak to see available patterns. Mossy Oak is a trademark used under license from Haas Outdoors,Inc.,by Kohler Co. Fuel System Accessories ❑ Flexible fuel line (included on OS models) I W-� NOTE: Dimensions are provided for reference only and should not be used for planning installation.Contact your local dealer for more detailed information. DISTRIBUTED BY: ©2023 Kohler Co.All rights reserved. G4-315 (26RCA) 4/23a 8 D p L119 00 I46.8 EXHAUST AIR OUTLET AIR INLET 189 .4 HIGH VOLTAGE ELECTRICAL Z STUB-UP AREA C LOW VOLTAGE C a STUB-UP AREA NZ •• • • • L6 w oo X Cm a m • cam M • •• 1813.11MAX / 9 CONDUITALLOWED �/ 91 3.6U 820 24.4J. 259 10.2 B OUTSIDE UNIT '374 NPT 817 32.2 (FUEML INLET 4X 3B 1.5 APPROX.MAX OPEN POSITION LIFTING HOLES 570 r22 4 337 r13.3i . • • •e• •o m NOTE:DIMENSIONS IN 0 ARE INCH EQUIVALENTS. Amu csos�is oR aw simu �eRs DO NOT SCALE. o ceaFnnALraERANCEs wA THIS ASSEMBLY OR PART MUST fO COMPLY WITH PEP-RML-001. ON COMPOSITE DINGS.SEE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR REV DATE O INDICATES PART NUMBERS AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. A •e• DRAWNO REVISION.O TWNIItmIE PADiSCRON - 11JAN2D22 NEWDRAWING AKH ®� KOHLER.. A A 11JAN2023 SEE SHEET2AND5 AKH MAJOR O-- S - _ _ _ 14FE82023 SEE SHEET 4 8 5 - -- - cRmcAL e= o M 11.0 O.a3 O CHARACTERISTICS COMPLYVATH SCALE:0.40 SHEET SIZE:B SHEET.I OF MOUNTING HOLES NPsmox2 236 rg.31 670 6.4 DRAN1t AKH I DATE: DIMENSION PRINT,26RCA 26RCA APPROVED:'yy 05DEC2022 Owe 0 8 7 6 5 4 msoAiw'INCHOE9iGx.wooErAn.6eaaERmrrsoPFnn Arm Must ror6e useoEllcEPrwmIME ROHrmm ROIaERw.wowL,ulwa Hre of�alanoR,xvwrion ARel�semFn.l P AIR CLEANER BREATHER TUBE D HEATER D (OPTIONAL) NGINE SHUTDOWN OIL FILTER SWITCH OIL DIPSTICK } OIL PRESSURE SWITCH COVER ARE HEATER(OPTIONAL) (OPTIONAL) r� K (. .' OIL FILL IL DRAIN VALVE EXHAUST OIL HEATER AIR OUTLET (OPTIONAL) �PLL 00.1ENSOBN�95NMwiT@ENs DO NOT SCALE. GENEMLTIXERANCES wA THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. ON COMPOSITE DWOS,SEE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR REV DATE D INDICATES PART NUMBERS AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. DRAWINOREVISION TwRDANGIEPRGJECTION A - 05DEC20 3 NEW DRAWING AKH ®� KOHLER. A A 11JAN202 D- OIL PRESSURE SWITCH COVER .. .. D _ __ __ _ (OPTIONAL)WAS OIL PRESSURE SWITCH camcAL®= o D 5 AKH CHARACTERISTICS COMPLY WITH SCALE:0.40 SHEET.-B SHEET:2 OF 5 B 14FEB2023 SEESHEET485 AKH NPs.Bwn TITLE: DRAWN: AKH DATE: DIMENSION PRINT,26RCA 25RCA APPR_SYSTEM 0I PI 5DEC2022 V. 8 7 6 5 3 2 1 TwSG GII GET NbIE GEFMYAtOYUSTNRBE USED E[CFYf GIGGwiEC11GNYATH NOHIERCO.WIXiKALL WGMSGF GELGN tliINVfNRONAPPRF9EAVED. 9 D USB PORTONTROLUER D l OAD CIRCUIT BREAKER USTOMER CONNECTION BLOCK FUEL REGULATOR HEATER PAD _ (OPTIONAL) OIL DRAIN HOSE BATTERY CABLES (INCLUDED) BATTERY LOCATION (BATTERY NOT INCLUDED) ATTERY HEATER (OPTIONAL) AIR INLET NLOWENST ONSSNMW➢IETERB DO NOT SCALE. eeNERnL7DLERases:wA THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. ON COMPOSRE DINGS,SEE PART NO.FOR REVISION IEVEL REFERENCE CAD MODEL FOR REV DATE ❑INDIGOES PART NUMBERS AFFECTED BY lA7E0 BY UNSPECIFIED DIMENSIONS. A DRAWING REVISION TmAunrr,�vRoarnox 05DEC2D221 NEW DRAWING AKHA KOHLER. A 11JAN2D23 SEE SHEET 2 AND 5 AKH B 14FEB2023 SEE SHEET 4&5 AKH — M 011 G=_ _ B cRmul O= B CHA TERISTICSCOMPLYWRH SCALE:0.40 1 SHEET Sae I SHEET:3 OF HPs soaaz TRIM DRAWN: AKH I DATE: DIMENSION PRINT,26RCA 26RCA APPRovED:sr�S 05DEC2022 D_ 8 7 6 5 3 2 ADY3; 919 Tni3 oAA woes cx Arro DErul fdlfRCO PRDFERfYANOIA/i NOT BE USED EAfF➢T NCONNECTIDN WIRE ItONIERCO.WORKALL RkiNIS OF YESiGNOR VNENfWNARE RESENYEO.I 8 7 6 4 21 OCCUPIED STRUCTURE OCCUPIED STRUCTURE D D NOTE: ,&THE RECOMMENDED DISTANCE FROM A STRUCTURE IS DEPENDENT ON STATE AND LOCAL CODES.PRODUCT HAS BEEN DEMONSTRATED IN ACCORANCE WITH NFPA 37 SECTION 4.1.4 BY A THIRD PARTY TEST FACILITY Z z TO THE DIMENSIONS SHOWN. C ACCEPTABLE C SERVICE DOOR SET 1)EXHAUST IS AIMED AWAY OR PARALLEL TO STRUCTURE. SET MOUNTING AREA GLINTING AREA 2)EXHAUST IS NOT DIRECTED AT PLAY AREAS,PATIOS OR OTHER AREAS WHERE PEOPLE CONGREGATE. SERVICE DOOR 3)THE NEAREST WINDOW,VENT,DOOR OR SIMILAR STRUCTURE 4 FT.CLEARANCE OPENING IS AT LEAST 5 FEET FROM THE EXHAUST END OF THE SET. AT EXHAUST END 4)SET HAS PROPER OFFSET FROM STRUCTURE. w o 5)WINDOWS 8 DOORS ON ADJACENT WALLS ARE CLOSED. UW 6)FURNACE AND OTHER SIMILAR INTAKES ARE AT LEAST 10 FEET FROM jEXHAUST END OF SET. V= 7)WEED BARRIER AND 3 INCH THICK GRAVEL BASE OR CONCRETE PAD TLOCATED TO O THE SET.PREVENT GRASS 8 WEEDS FROM GROWING TOO CLOSE v¢ 6)NO PLANTS,SHRUBS OR OTHER COMBUSTIBLES ALLOWED IN OCCUPIED z CLEARANCE AREA.(MINIMUM 4 FT.FROM EXHAUST END). B STRUCTURE m a B 9)REFER TO OWNERS MANUAL FOR OTHER INSTALLATION CONSTRAINTS. 10)NO PLANTS,SHRUBS,OR OTHER COMBUSTIBLES ALLOWED WITHIN IS'MIN. 30'OF AIR INTAKE. Q 11)MUST MAINTAIN A MINIMUM OF 3 FEET CLEARANCE FROM SERVICE DOOR ENTRANCE. SERVICE DOOR 12)OVERHANGS AND AWNINGS MUST BE A MINIMUM OF 5 FEET FROM GENSET. SET MOUNTING AREA AiL oo DT�w sN NPELWIPIETFAs DO NOT SCALE. V i THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. N ON COMPOSITE DINGS,SEE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR Q REV DATE OINDICATESPARTNUMBERSAFFECTEDBYLATEST BY UNSPECIFIED DIMENSIONS. A u7 Q ORAWINGRENSION 7 S TWROAIMIE PROIECIWN - 11JAN2022 NEW DRAWING AKH ®� KOHLER._ A c¢ A 11JAN2023 SEE SHEET 2 AND 5 AKH ,,LAIoa o• o- B 14FEB2023 B-2 3 FEET CLEARANCE WAS 5 FEET camcAL®• a CLEARANCE•SEES E 5 AKH CHARACTERISTICSCOMPLY WITH SCALE:0.40 SHEET See B sHEEr:4 OF 5 HPsawa TDLe 26RCA DRAWN: AKH DATE° DIMENSION PRINT,26RCA 6FIGUR UNIT A Ovm..S�P�"05DEC2022 CONFIGURATION SYSTEM 919 D. 8 7 6 5T PaoPeR wsT WUMD PAcm wcro wZimnrmm•mAFNcawaRaAu wD rts oP ors cHo wvPxrlaN PAeREs 8 OCCUPIED STRUCTURE OCCUPIED OCCUPIED STRUCTURE STRUCTURE 18'MIN. SERVICE QDOOR 1 SERVICE Z SET SET MOUNTING— DOOR REAMOUNTING $a AREA z � z wo ro zw 3FT' Uz zw MOUNTING SERVICE Ill AREA DOOR SET O U SET SERVICE SET PUNTING w DOOR AREA MOUNTING AREA �¢ ¢ C E DOOR C a ��ATW.-.=�UE OCCUPIED Z STRUCTURE 2 wo zw 3FT. z a m 4aN Q 4aN SET ¢ OUNTING AREA 18'MIN. i w 1 dim O w SERVICE DOOR ¢ ¢ 4 FT.CLEARANCE SET SERVICE DOOR cJi= AT EXHAUST END MOUNTING AREA ri v¢ N O .D OCCUPIED STRUCTURE I 9 �Wu� B mw 7w QN J Q i SET SERVICE DOOR O 2 m a �w MOUNTING AREA v MOUNTING AREA MOUNTING AREA NOTE: SET SET APPLY NOTES ON SHEET 4 OF 5 suoun°EeTMisIEGnis W YPEGPEG Ej DO NOT SCALE. TO SHEET 5 OF S. GFrgwuTar=lw+cey.,yn THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. SERVICE ON COMPOSITE DWOS,SEE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR 4 FT.CLEARANCE SERVICE REV DATE D INOICATEBPART NUMBERS AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. q AT EXHAUST END DOOR DOOR OMW NO REM ION TN�u�E�a E�nN 4 FT.CLEARANCE - 05DEC2022 NEW DRAWING AKH ®� KOHLER. q AT EXHAUST END A 11JAN2023 A4 5 PARALLEL UNIT WAS SINGLE UNIT: Ma o. D _ _ SEES EET 2 AKH CRMCAL 6- INTAKE TO B 14FEB2023 (G6,7)(G2)3 FT.WAS 5 FT.;SEE SHEET 4 AKH CKMR TERISTICSCOMPLY WRH S�LE:0.40 snEEi S¢E:B snEEi:5 OF 5 BE 10 FT. NP% FROM EXHAUST Tine 26RCA DRAWN' AKH DATE DIMENSION PRINT,26RCA PARALLEL UNIT APPaovED:S�Pu OSDEC2022 CONFIGURATION _ SYSTEM o 8 7 6 5 4 TEg dUW NGg pE51GN ANp pETNLIg KCNERLp.PRpPER YY0 NU9T N(gEUGEO EKCEP MLONNECTONW KGN FRCP.WORK ALL WGNBapES GNGRINYENfK NMRIGigERYm.