Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
48051-Z
�oyaoF SO�ryo�o Town of Southold * * P.O. Box 1179 0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45975 Date: 02/13/2025 THIS CERTIFIES that the building SINGLE FAMILY DWELLING Location of Property: 6025 Aldrich Ln Mattituck, NY 11952 See/Block/Lot: 120.-3-11.22 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 06/08/2022 Pursuant to which Building Permit No. 48051 and dated: 07/11/2022 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Relocated single family dwelling with additions and alterations including a front covered entry, rear covered porch and an unfinished basement as applied for. The certificate is issued to: Aldrich Acres Trt Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: R-21-0151 ELECTRICAL CERTIFICATE: 48051 11/22/2024 PLUMBERS CERTIFICATION: George Berry Jr 12/5/2024 Au orize S'gna re �SVFFe TOWN OF SOUTHOLD ��o yyy BUILDING DEPARTMENT H x TOWN CLERK'S OFFICE oy • oar SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48061 Date: 7/11/2022 Permission is hereby granted to: P & ELLC c/o Peter Harbes 1002 Bluff Dr N Baiting Hollow, NY 119.33 To: Construct new foundation under existing (relocated) single family dwelling and construct porch additions as applied for, with SCHD approval. Additional certification may be required for existing dwelling. At premises located at: 6025 Aldrich Ln., Mattituck SCTM #473889 Sec/Block/Lot# 120.-3-11.22 Pursuant to application dated 6/8/2022 and approved by the Building Inspector. To expire on 1/10/2024. Fees: FOUNDATIONS UNDER EXISTING BUILDINGS $200.00 SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $395.20 CO-RESIDENTIAL $50.00 Total: $645.20 Building Inspector o��OF SO!/�yQ! � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Southold,NY 11971-0959 �Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: P&E LLC Address: 6025 Aldrich Ln City: Mattituck St: NY Zip: 11952 Building Permit#: 48051 Section: 120 Block: 3 Lot: 11.22 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Indoor Basement 170 Service Solar (- Outdoor r 1st Floor PF Pool F Spa r Renovation r 2nd Floor ry-1 Hot Tub r Generator Survey "FV Attic F Garage Battery Storage r INVENTORY Service 1 ph F Heat Duplec Recpt 47 Ceiling Fixtures 12 Bath Exhaust Fan 3 Service 3 ph F Hot Water G2S GFCI Recpt 14 Wall Fixtures 1 Smoke Detectors 5 Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures 24 CO Detectors Sub Panel A/C Blower 2 Range Recpt Gas Ceiling Fan 1 Combo Smoke/CO 3 Transfer Switch UC Lights 12' Dryer Recpt Gas Emergency Strobe Heat Detectors Disconnect Switches 43 4'LED 3 Exit Fixtures Other Equipment: Fridge, Oven, Hood, DW, W/D, 200A Panel 42 Circuits /40 Used Notes: " AS BUILT NO VISUAL DEFECTS " Kitchen, Basement, 2nd Floor Bath & Devices & Service Inspector Signature: X Date: November 22, 2024 Sean Devlin Electrical Inspector sean.devlin(d-)town.southold.ny.us S.Devlin-Cert Electrical Compliance Form 2 - ��oF soUryo ,moo • � Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 � • Southold,NY 11971-0959 :AZ BUILDING DEPARTMENT TOWN OF SOLYMOLD DEC M4 ; CERTIFICATION Date: Z 4 I Building Permit No. g ; Owner: �Ar3Es (Please print) Plumber: cO d • e. e.A: lease print) I certify that the solder used in the water supply system contains less than 2/10 of 1% 1 lead I� " r ! X� (Pl umbers SigVW s , Sworn to before me this day of 20.2,q - Notary Publi ] County VICKI•t`BERRY Notary Public-State-of'-New York No. 01 BE6070081 Qualified in Suffolk Cou Commission Expires—�t4 i lvol� 0f SO f TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION [ ] UNDATION 1ST [ ] ROUGH PL13G. [ FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [. ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS c DATE INSPECTOR I OF SOUTHOLD # TO BUILDING DEPT.cou INSPECTION [/] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE Y4 ho�apF SOUIyO� 57 Cj6 - # # TOWN OF SOUTHOLD BUILDING DEPT. courmN�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O RENTAL [ ] RENTAL REMARKS: M o,P-� o AY2 V 10) r K/9' f A ) f 8-01 144O)e DATE 2, &/ 23 INSPECTOR Y� �F SOUIyOlo Ds L0�Z� c- r ' G -- - TOWN OF SOUTHOLD BUIL I : G DEP . lourm,��' 631-765-1802 i INSPECTION ' [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ . ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: e Q v� 4)u2 DATE �� INSPECTOR OF SOGTyo� L46 05I # # TOWN OF SOUTHOLD BUILDING DEPT. 0 rm �0 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ } .FIREPLACE &CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE'RESISTANT CONSTRUCTION [ ] FIRE RESISTANT:PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 4-) DATE la ' INSPECTOR OF SO(/TyO� * TOWN .OF SOUTHOLD BUILDING DEPT. y uffv, 631-765-1802 ooSi INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ NAL-64 * [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)- [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: @ m Tqv��, V hal4A �wrd, U. I I Allkl DATE l [I, INSPECTO tf SOUI Alc(rrc_� `+s l # TOWN OF.SOUTHOLD BUILDING DEPT. i'oum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY. [ ] FIRE,SAFETY INSPECTION [ . ] FIRE RESISTANT CONSTRUCTION [ ]. FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O : [ ]- RENTAL REMARKS: 4 41 24 41 &�A r haL67MCAV 4— cl wr e-es- V(71!1 LGA Ve!5' 7�t�i DATE j INSPECTOR FREIDERICK 41 EAST MAPLE ROAD, GREENLAWN, NY 11140 52 NOYACK PATH, WATER MILL, NY 11916 ROBERT Neberarchetecteyahoo.com 631 154-5555 WE CE TTECT D E" CEIVE February 12,2025 F EB 12 2025 RE: DDANIIARBES-HOUSE RELOCATION Building Department 6025 Aldrich Lane,Mattituck,New York Town of Southold Southold Town Building Department, The Dan Harbes Residence (6025 Aldrich Lane, Mattituck)was moved from another location in Southold(Hallock Lane,Mattituck). The existing house structure had a Certificate of Occupancy which allowed the undisturbed parts of the existing structure to remain as is. The existing wall,floor and roof framing were not changed, and interior wall finishes were not removed(except for small sections in the kitchen&2nd floor bath) so no review was made of existing framing, insulation, electric work or plumbing in these undisturbed areas. The majority of the existing windows and doors remained. The new work performed involved the construction of a new poured concrete foundation, relocating the house onto this foundation and constructing surrounding porches. New exterior siding and trim were installed as well. A new front door and kitchen window were added. Plumbing work was extended from the projection through the l'floor structure to the new sanitary system and new well. The water supply piping in the exposed basement ceiling was changed to.Pex and the new waste piping was PVC extended from the existing. Electrical work was also extended to a new electrical service. A new boiler,water heater and air conditioning equipment were installed.New insulated ductwork was installed in the basement&attic and then connected to existing ductwork. All new work including concrete foundation work,new framing of porches, strapping and anchoring of construction and rough plumbing work were performed in conformance to the 2020 Residential Code of New York State to the best of my knowledge,information and belief. The floor joists between the I"floor and basement were sealed and insulated with Roxul R21 (RI9 prescriptive code minimum) and the rim joist space were sealed and insulated with closed cell insulation(R13)in conformance with the 2020 Energy Conservation Construction C de of New York State. t }. . ,j 1Y F K R. R.A. a G ; -4 r � j 2/10/25,8:24 AM Security Window Film Roll-48"x 25',4 Mil S-23620-Uline My Account I Contact Us I Sign In I .Cart $0.00 ULPNE1-800-295-5510 - Search Go Products Wine Products Quick Order Catalog Request Special Offers About Us Careers I Home > All Products > Tape > Surface Protection Tape > Security Window Film I i Security Window Film Roll - 48" x 25', 4 Mil Holds shattered glass in place to prevent entry, Injury or damage.. • Use in stores,offices and homes.- • Blocks 99%of UV rays. • Accessories(sold separately): "= Film Solution-Required for proper application. �:—-" =-�' /` Application Tool Kit-Includes.squeegee,hand applicator and knife. r O;Mote Images Pressure Sensitive Adhesive MODEL %OF UV PRICE.PER ROLL IN,STOCK " NO." COLOR ROLL SIZE MIL BLOCKED 1 J 2 1 4+ SHIPS TODAY. :. : . . . S-23620 Clear 48"x25' 4.0 99% $230 $222 015 Y _ "' ADD O Additional Info M ShoR n LI s Request a.Catalog. . MATERIAL: Availability:In Stock. • Polyester Unit Weight:7.44 Ibg. SHELF LIFE:. Instructions • 1 year Catalog Pagg 834 FEATURES: Email Item • Scratch resistant S• Excellent-heat rejection. Country of Origin:USA • Not fire rated. 4 PECIFICATIONS: • Meets ANSI Z97.1 USAGE:- • Film Solution allows to position the film Into place. • Apply to Interior of single and dual pane windows. • Window film helps reduce fading but does not eliminate It. o Nothing completely eliminates fading.. • Not for use on cars. • Not for use on Plexiglas®or polycarbonate. I t SAME DAY SHIPPING I HUGE SELECTION IN STOCK I SHIPS FROM 13 LOCATIONS https://www.uline.com/Product/DetaiUS.-23620/Surface-Protection-Tape/Security-Window-Film-RoII-48-x-25-4-Mil 1/1 f i .,ter:•�":. � � - �L. r.>_ HIM • ri v+�}• `40. Tw-1 ct r L ` �` � .. c ..- - � ""`vow".•'_:�.. � r }�. t� FIr,LD INSPECTION REPORT PATE COMMENTS FOUNDATION (1ST) ---------------------------------- WX FOUNDATIONY W © D (2ND) z 0 H ROUGH FRAMING& �? PLUMBING 1 �a9 r INSULATION PER N.Y. y STATE ENERGY CODE tA FINAL �K l O F� Ci ADDITIONAL COMMENTS D -0 Z 22 c� o 2f �U Z3 - r 18Lf�� m 51 o sq cZ, IL 2,00 re c,* /0"737y a- v,� .� y z �x � x C�d ti o�osuFFacKooG TOWN OF SOUTHOLD—BUILDING DEPARTMENT s= Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o� ,�aa Telephone (631) 765-1802 Fax(631) 765-9502 hgps://www.southoldto) nM.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only (� (�® F- (7 PERMIT NO. Building Inspector: Ili I- U JUN 0 8 2022 Applications and forms must be-filled-out in their entirety.Incomplete 7BUN-DING DEPT 'applications will not be accepted. Where the Applicant-is not the owner,`an TOWN OF SOJTHOLD Owner's Authorization form-(Page 2).shall be completed. Date: �'v h e © a� OWNERS)OF-PROPERTY:. Name: t SCTM#1000- s rap Il aL -�-.�- . .e - - Project Address: dl- - Phone#^ � 3_.(_ ._aT 5 ' L4 9.1..3..._.-__. ...-.___.___._ Email -car s(2 I SA I itsice_,.LovK_ Mailing Address: _--.. 4�..._ _._�t_. /�_. o_x __r._ _ _ _-- _�-t-�-.-�-� _ _ _ ._____ CONTACT:PERSON: Name: -�` Mailing Address: La,ti _Lv'&e S Phone#: (03 / 76 . - - Email:y c; ov�coc-c_e�- _! � o_c.�i_w�d 'fi DESIGN PROFESSIONAL INFORMATION``:, Name: Mailing Address: �}( �45-f (V�� e ((� 94 ( cae..LA, Phone#: (o I 5. 'S-. -- .. ...._ Email:.W 4!O rav c�;_Te—A @ a400. coo.1 CONTRACTOR INFORMATION: Name: 1 ' 5Ce V%N .��F a-ws a S- Mailing Address: -ot-OL V_ Q_7 ,:ir o c e - �3 - --- Phone#: — r Email: 73 .. bk . c. .a-.r.C.o V►5 U�-c G-!D .c�o�._ DESCRIPTIONNOF.PROPOSED.CONSTRUCTIO4.4 ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: i(Other f�,5 5�" le �r0.wc'�� rk�ae(�:K ka5 {peek AoveA1_5 ZGa-- �-G __--_._._- --__ ------..__.--------_ Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? ❑Yes AN'o 1 S GT 4T- Lot I/. ap PROPERTY INFORMATION Existing use of property: 4 Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to (� this property', ❑Yes No IF YES, PROVIDE A COPY:.* Check Box-After Reading: The owner/contractor/design profesiional is responsible'for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone- Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors,on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A-misdemeanor pursuant to Section 210.45 of the New York State Penal Law., c-a Le-e s e es-r�y l:54Q� Application Submitted By(print name): E'JAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF 5uffoLC ) 0 , V (-E(-- 3 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ' day of 20 ZZ- `/✓ mot Notary Public JULIA H.HART NOTARY PUBLIC,State of New York PROPERTY OWNER AUTHORIZATION No.01HA4872284 Qualified in Suffolk County (Where the applicant is not the owner) Commission Expires Sept.29, I, ( +L(f)-lei S residingat ::7f5 4WC0(fX �41vel A/`/ f2��7TTUCG� do hereby authorize s �o4M y t4c ) J �o Tf-e—le to apply on my behot the Town of Southold Building Department for approval as described herein. g:� Owner's Signature Date P9411zc #/Mp2 :s Print Owner's Name 2 �Qg�FFO( MAR 16 202 L ING DEPARTMENT-Electrical Inspector 4 G TOWN OF SOUTHOLD yJ` B�Il,®11�G®E n Hall Annex- 54375 Main Road - PO Box 1179 ti TOWNOFS65 ^* Southold, New York 11971-0959 �4-1 Telephone (631) 765-1802 - FAX(631) 765-9502 ro e r southoldtownn ov— seand southoldtownnV.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (AI Information Required) Date: .3 - Ao -a3 Company Name: GJS Electric, LLC Electrician's Name: Gary Salice License No.: 4839ME Elec. email:gary@nfay.com Elec. Phone No: 631-298-4545 01 request an email copy of Certificate of Compliance Elec. Address.: 6615 Main Rd., Ma ituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: -,, S Cross Street: Sou,, e, Phone No.: Bldg.Permit#: q g O email: Tax Map District: 1000 Sectic : l R 0 Block: Lot: , 2� BRIEF DESCRIPTION OF WORK, INC UDE�SQUARE FOOTAGE (Please Print Clearly): J�oo QV � un kr uno( Svc. Square Footage: Circle All That Apply: Is job ready for inspection?: YESIN ❑Rough In ❑ Final Do you need a Temp Certificate?: YES❑ NO Issued On ��35 Temp Information: (All information required) Service SizeQ Ph n3 Ph Size: A #Meters Old Meter# New Service[]Fire Recon''--nrre----'ct❑Floo Reconnect❑Service Reconnect21Underground❑Overhead #Underground Laterals 1 2 H F ame Pole Work done on Service? P<Y DN Additional Information: PAYMENT DUE WITH APPLICATION Svc$k5 / ®01 ® BUILDING DEPARTMENT-Electrical Inspector ® TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road-PO Box 1179-Squthold, NY 11971-0959 �lpl �®� Telephone (631) 765-1802 Temporary Certificate # 1436 Date - ,l � - 2023 Customer Name 1�� Electrician Name 61S Address ��Z� I di'-j ch / 1' j utlt Phone Q 5 e-mail e-mail ar &IrAvr �y�yti Phone n License# �O/ lie Size e c 6y A Phase Overhead Underground V111 #of Meters Remarks #of Underground Laterals 1 2 New "H" Frame or Pole H P Fire Reconnect Was work done on Service? Y/ Flood Reconnect Old Meter# Service Reconnected Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this installation is complete,the town will conduct a premises inspection of the service equipment. This verification i�vall�id ,90=sfrom e date abo . Authorized by -------------------•---------------------------- o4�g�EEO(,��oG BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o x Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrl@-southoldtownny.eov- seand(cDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Cj - 0- Company Name: G' JS Name: S1 License No.: l.� 3q 1 email: ar @ n V o C-0 m Phone No: 3 -,a4 g- I request an email copy of Certificate of Compliance Address.: Maay-, & �I JOB SITE INFORMATION (All Information Required) a Name: k- LLC C/o Pe-+ee- 4--&�s Address:-(^r 0 X$ ane �'j Cross Street: ti,vh4 Phone No.: Bldg.Permit#: 4!9 email: Tax Map District: 1000 Section: p Block: `Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) 4 ill Check All That Apply: I Is job ready for inspection?: 1ky' ES ❑NO ❑R Final Do you need a Temp Certificate?: DYES 2NO Issued On II'I Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals 01 ❑2 ❑H Frame❑Pole Work done on Service;? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION �oo -1 I e z re-d* 1 d-731 Electrical Inspection Form 2020.xlsx �fFQ( BUILDING DEPARTMENT-Electrical Inspe for TOWN OF SOUTHOLD o =` Town Hall Annex- 54375 Main Road - PO Box 1179 `; '� Southold, New York 11971-0959 u �4,, a©�� Telephone (631) 765-1802 - FAX (631) 76 -9502 rogerr(aD-southoldtownny.gov - seand0southoI townny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: L,L. Name: S rL License No.: 3q M L- email: �i'" G� n f a v, c o lk Phone No: 3 -a4 T- I request an email copy of Certificate pf Compliance Address.: (o cUn A r JOB SITE INFORMATION (All Information Required) Name: P It F- L L-C, Address:_(0 0 2-;, 41 Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: ,p; Block: ��,,ILot: qi , .1-Q, BRIEF DESCRIPTION OF WORK (Please Print Clearly) Check All That Apply: Is job ready for inspection?: ES ❑NO ❑R Final Do you need a Temp Certificate?: DYES &]NO Issued On � Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals 01 ❑2 ❑H Frame ❑Pole Work done on Service? Fly'. ❑N Additional Information: PAYMENT DUE WITH APPLICATION 1 ��(- � n^()sa t o z� rcc# )0-731 Electrical Inspection Form 2020.xlsx PERMIT# Address: Switches C f Outlets G GFI's Surface Sconces H H's E C l� n 1c I UC Us /1 Fridge HW POOL 5 Fans � Mini Fr. W/D Panel Pump p Exhaust �'1 Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon i, Micro GrbDis Water Bond.. Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC 1 AH Hood Blower Service Ampg7_ Have Used lJ u Sub Amps Have Used Comments c Gro�T OFFICE LOCATION: MAILING ADDRESS: Town Hall Annex Dg SO(/T ' P.O.Box 1179 54375 State Route 25 O�� y�l Sodlthold,NY 11971 (cor.Main Rd. &Youngs Ave.) O Telepli'one:631 765-1938 Southold,NY ] l�[ II www.southoldtownny.gov coum��` PLANNING BOARD OFFICE TOWN OF SOUTHOLD January 11, 2022 Charles R. Cuddy, Esq. P.O. Box 1547 Riverhead, NY 11901 Re: Harbes Open Development Area: Final Plat Approval Located at 5645 Aldrich Lane, on the west side of Aldrich Lane +/- 1,300' south of Sound Avenue, in Laurel; SCTM#1000-120.-3-11.11 Zoning District: A-C Dear Mr. Cuddy: The Southold Town Planning Board adopted the following resolution at a Public Meeting held on Monday, August 10, 2020: WHEREAS, on August 25, 2009, pursuant to Southold Town Code Chapter 240 Article VIII Open Development Area, the Town Board granted the applicant the right to seek future approval of the creation of lots; and WHEREAS, this proposal is for the creation of the lots in an approved Open Development Area for an 80/60 conservation subdivision pursuant to Southold Town Code §240-26 Establishment; and WHEREAS, the Lot Creation will subdivide a 22.17-acre parcel into 4 lots, where Lots 1, 2 & 3 are 1.26-acre residential lots and Lot 4 is an 18.38-acre farm with the development rights held by Southold Town; and WHEREAS, the Planning Board granted Conditional Final Plat Approval for the Lot Creation on August 10, 2020; and WHEREAS, on October 22, 2021 the Park & Playground fee in the amount of$7,000 and the Administration Fee in the amount of$6,000 were submitted; and Harbes ODA Lot Creation Page 12 January 11, 2022 WHEREAS, on December 16, 2021, four mylars and twelve copies of the Final Plat including the approval stamp of the Suffolk County Department of Health Services and all required revisions were submitted; and WHEREAS, on January 6, 2022 a copy of the recorded covenants was submitted; and WHEREAS the Planning Board has found that the all conditions of the Conditional Final Plat Approval have been met; therefore be it RESOLVED, that the Southold Town Planning Board grants a Final Plat Approval upon the map entitled, °80/60 Conservation Subdivision Peter Harbes", prepared by Howard M Young, Land Surveyor, dated February 13, 2013 and last revised November 11, 2021. Upon endorsement of the Final Plat by the Chairman, the mylars and paper prints must be picked up at this office and the Final Plat filed with the Suffolk County Clerk by the applicant within 62 days of the date of Final Plat Approval, or such approval shall expire. The Final Plat approval is void if the Final Plat is revised after approval. No changes, erasures, modification(s), or revisions shall be made to any Final Plat after it has been approved by the Planning Board, and such approval has been endorsed in writing on the plat, unless the said plat is first re-submitted to the Planning Board and the Planning Board approves any modifications by resolution. In the event that any such Final Plat is filed without complying with this requirement, the same shall be considered null and void, and the Planning Board shall institute proceedings to have the Final Plat stricken from the records of the Suffolk County Clerk. If you have any questions regarding the information contained in this resolution, please contact the Planning Board Office. Respectfully, ` �' �(-)DZ Donald J. Wilcenski Chairman 4 • MAILING ADDRESS: PLANNING BOARD MEMBERS �0�S�Ury P.O.Box 1179 MARTIN H.SIDOR h�� 0� Southold,NY 11971 Chair OFFICE LOCATION: WILLIAM J.CREMERS y Town Hall Annex KENNETH L.EDWARDS G + �� 54375 State Route 25 GEORGE D.SOLOMON (cor.Main Rd. &Youngs Ave.) JQSEPH L.TOWNSEND �� � Southold,NY Telephone:631 765-1938 Fax:631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD State Environmental Quality Review NEGATIVE DECLARATION Notice of Determination of Non-Significance August 25, 2009 This notice is issued pursuant to Part 617 of the implementing regulations pertaining to Article 8 (State Environmental Quality Review Act) of the Environmental Law. The Southold Town Board, as lead agency, has determined that the proposed action described below will not have a significant effect on the environment and a Draft Environmental Impact Statement will not be prepared. Name of Action: Proposed Open Development Area for P&E, LLC SCTM#: SCTMs#1000-120-3-11.11 Location: 5645 Aldrich Lane, Laurel, NY 11901 SEAR Status: Type I ( ) Unlisted (X} Conditioned Negative Declaration: Yes ( } No (X) Description of Action: The establishment of an Open Development Area located on 3.78 acres of the 22.17+/-acre parcel with the Open Development Area consisting of three.lots of approximately 1.26+/-acres per lot and the remaining 18+/- acres to be acquired by the Town using Community Preservation Funds and subject to a development rights easement. i Reasons Supporting This Determination: An Environmental Assessment Form has been submitted and reviewed and it was determined that no significant adverse effects to the environment were likely to occur should the project be implemented as planned. The determination was based upon the following: This project will create an open development area on a 22.1659-acre parcel; preserving 18.3779 acres of agricultural farm land. The development rights on the preserved 18.3779 acre parcel, will be sold to the Town of Southold. The remaining 3.783 acres are being subdivided from the preserved land to allow for the potential future development pursuant to Article Vlll of Southold Town Code which states"the Town Board may grant the applicant the right to seek future approval of the creation of lots and the issuance of permits for the erection of structures to which access is given by right-of-way or easement. Such right shall be in accordance with the designated zoning district and the density and minimum lot size for the property in effect at the time of the establishment of the open development area." In the event that the open development area is developed in residential lots, the permissible maximum yield is three. The three lots would be recognized as clustered lots. The subdivision open space of the clustered lots would equal 1.73 acres and comprise a portion of the preserved area. The proposed action will not result in: I. A substantial adverse change in existing air quality, ground or surface water quality or quantity, traffic or noise levels, no substantial increase in solid waste production, potential of erosion, flooding, leaching or drainage problems will occur as a result of this action. 2. A significant removal or destruction of large quantities of vegetation or fauna, no substantial interference with the movement of any resident or migratory fish or wildlife species, no significant impacts on a significant habitat area, no substantial adverse impacts on a threatened or endangered species of animal or plant or the habitat of such a species, and no other significant adverse impacts to natural resources will occur. 3. A significant impairment in the character or quality of important historical, archaeological, architectural, or aesthetic resources or of existing community or neighborhood character. 4. A major change in the use of either the quantity or type of energy. S. The creation of a hazard to human health. 6. A substantial change in the use, or intensity of use, of land including agricultural, open space or recreational resources, or in its capacity to support existing uses. 7. Material conflict with the community's current plans or goals as officially approved or adopted by the Town of Southold in that this proposed action is reducing density and preserving 80 percent or 18.37 acres of the buildable lands currently in agricultural production. Based upon such, no significant adverse impacts to the environment are expected to occur should the project be implemented as planned. For Further Information: Contact Persons: Mark Terry, Principal Planner or Tamara Sadoo, Planner Address: Southold Town Planning Board Telephone Number: (631) 765-1938 RESOLUTION 2009-731 ADOPTED DOC ID: 5253 THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION NO.2009-731 WAS ADOPTED AT THE REGULAR MEETING OF THE SOUTHOLD TOWN BOARD ON AUGUST 25,2009: WHEREAS,on August 10,2009 the Southold Town Planning Board granted Sketch Approval on the Sketch Plat prepared by Howard W. Young, L.S.,dated May 27,2009 and last revised on July 2,2009 for a Conservation Subdivision pursuant to 240-26(A)of the Town Code;and WHEREAS,the Town Board has received a petition from P&E, LLC to establish an open development area pursuant to Chapter 240 of the Town code on property identified as part of SCTM#1000-120-3-11.11 and located in the A-C zoning district; and WHEREAS,the requested Open Development Area is located on 3.78 acres of the 22.17+/- acre parcel with the Open Development Area consisting of three lots of approximately 1.26+/- acres per lot and the remaining 18+/-acres to be acquired by the Town using Community Preservation Funds and subject to a development rights easement; and WHEREAS,on August 11, 2009 the Town Board adopted a resolution accepting the petition as complete and setting the public hearing for August 25,2009; and WHEREAS,on August 25,2009,the Town Board held and closed a public hearing on the proposed establishment of the Open Development Area; and WHEREAS,the Town Board finds that the requirements for the establishment of an Open Development Area pursuant to Southold Town Code Chapter 240,ARTICLE VIII,Open Development Area have been met; and WHEREAS,the proposed action has been reviewed pursuant to Chapter 268 (Waterfront Consistency Review)of the Town Code and Local Waterfront Revitalization Program(LWRP) and the LWRP Coordinator has recommended that this action is consistent with the LWRP;now, therefore be it RESOLVED that the Town Board of the Town of Southold establishes itself as lead agency and, as lead agency,makes a determination of non-significance and grants a Negative Declaration; and it is further RESOLVED that the Town Board of the Town of Southold hereby grants approval for the establishment of an Open Development Area for P&E, LLC on the map prepared by Howard W. Young, L.S.,dated May 27, 2009 and last revised on July 2,2009 subject to the following conditions: } Resolution 2009-731 _ Board Nieeiing of August 25,2009 1. The approval of the Open Development Area shall not be valid if the Sale of the Development Rights to the Town is not completed and a copy of the recorded deed of development rights is not submitted to the Town of Southold Town Board on or before one year from the date of this approval. 2. Submission and recording with the Suffolk County Clerk of covenants and restrictions on the Open Development area containing the following provisions: a. The establishment of a perpetual vegetative buffer on each lot between the agricultural use and the residential use properties. The buffer shall be comprised of evergreen plants of such type,height, spacing and arrangement as will effectively screen the activity on the lot from the agricultural area.As a minimum,the planting shall consist of a double row of trees 6 feet in height planted at intervals of 10 feet on center. b. All landscaped areas shall contain indigenous,drought tolerant vegetation in landscaping to minimize irrigation and the use of synthetic fertilizers and herbicides. c. All driveways shall be constructed of a pervious material. d. Installation of gutters, leader and drywells. The proposed action has been reviewed pursuant to Chapter 268(Waterfront Consistency Review)of the Town Code and the Local Waterfront Revitalization Program(LWRP)and the Town Board of the Town of Southold has determined that this action is consistent with the LWRP. Elizabeth A.Neville Southold Town Clerk RESULT: ADOPTED [UNANIMOUS] MOVER: Thomas H. Wickham,Councilman SECONDER:Louisa P. Evans,Justice AYES: Ruland, Orlando,Krupski Jr., Wickham,Evans,Russell Updated: 8/25/2009 3:23 PM by Lynne Krauza Page 2 MAILING ADDRESS: PLANNING BOARD MEMBERS �o�\\Of so P.O.Southold, x 1179 1 971 MARTIN H.SIDOR Chair OFFICE LOCATION: WILLIAM J.CREMERS Town Hail Annex KENNETH L.EDWARDS @ 54375 State Route 25 JGEORGE OSEPH L.D. SOLOM N O`i�' � (cor.Main Rd.&Youngs Ave.) ( Southold,NY Telephone:631 765-1938 Fax:631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD August 11, 2009 Charles R. Cuddy, Esq. P.O. Box 1547 Riverhead, NY 11901 Re: Sketch Approval: Proposed Conservation Subdivision for Peter Harbes Located at 5645 Aldrich Lane, Laurel SCTM#:1000-120-3-11.11 Zoning District: A-C Dear Mr. Cuddy: The Southold Town Planning Board adopted the following resolution at a meeting held on Monday, August 10, 2009: The public hearing was closed. WHEREAS, this proposed conservation subdivision is to subdivide a 22.1659 acre parcel into four(4) lots. Lot 1 equals 1.2650 acres (55,100 square feet), Lot 2 equals 1.2650 acres (55,100 square feet), Lot 3 equals 1.2580 acres (54,800 square feet)and Lot 4 equals 18.3779 acres (800,544 square feet)from which The Town of Southold will purchase the Development Rights in August 2009 for the purpose of farmland preservation; and WHEREAS, an application for sketch approval was submitted on June 26, 2009, including the sketch plan prepared by Howard W. Young, L.S., dated May 27, 2009 and last revised July 2, 2009; and WHEREAS, on July 6, 2009, the Southold Town Planning Board, reviewed and accepted the application for formal review; and WHEREAS, this proposed conservation subdivision has 74,998 square feet of clustered conservation open space located within Lot 4"Agricultural Preserve"which shall remain unbuiidable pursuant to Southold Town Code §240-42; and WHEREAS, on July 8, 2009, referrals were sent to the following agencies for comment on the above-referenced project: Peter Harbes Page Two August 11. 2009 • Town of Southold Engineer • Town of Southold LWRP Coordinator • Suffolk County Planning Commission; and WHEREAS, on August 6, 2009, Suffolk County Planning submitted their comments and approved the above-referenced application; and WHEREAS, on August 6, 2009, the Southold Town LWRP Coordinator submitted comments on the above-referenced application; and WHEREAS, on August 6, 2009, the Southold Town Engineer submitted comments on the above-referenced application; and WHEREAS, those comments have been considered and accepted by the Southold Town Planning Board and have been incorporated into the sketch plan for the above- referenced application; and WHEREAS, the submitted application meets all of the requirements for sketch approval; be it therefore RESOLVED, that the Southold Town Planning Board hereby grants Sketch Approval on the Sketch Plat prepared by Howard W. Young, L.S., dated May 27, 2009 and last revised on July 29, 2009. Sketch Plan Approval is valid for six months from the date of issuance, unless extended by resolution of the Planning Board. If you have any questions regarding the above, please contact this office. Very truly yours, Martin H. Sidor Chairman 400 Oat-ender Avi—I,taverhead,Neq York 119OI N �W.b3ladm N.Y.S.PLANE D�tlt�fK � ^5 NAD 53vv / �2 / %'�' ♦� ♦ Rober Rest t C.Tmt, 1 0 `\ Dwylm E Ad—,P-11—II—Il Bgi— \1 vtyo W E 51TE DATA C� S pC�C`00' � �\ TOTAL AREA=22.1654 ACRES "♦ ``\ ♦ d ADS 9D _ \ I " G OYNER =P H E,PETM BES oA I \/j 1 °`` �� 5640 5 ALVWC4 LANE LAMEL.TEN YORK IIVA ZONINS use DISTRICT A-G VHtnCAL PATLM a"M DATW(MS.L.1`1297 9 ` NOTE,TOPOOPAPW S OM YHEGN 15 FROM ACNK FIFA 5URVEY AND FIVE EASTERN TO NT6 TOP06RAPHICAL SURVEY PREPATRED d \ l ✓( \� `\ FOR SLIFFOLK CWNTY. TIE IN %% ra 1`u1 9/y9\\ 80/60 GON5ERVATION SUBDIVISION IQ 532°I0'40'E 'F50.62' °C ' 536°I2'10'E 206A5' ``\ O 9j \ BUILDABLE LARDS .22.W69 ACRES Q` °42'10'E 46.93' op \ — YIELD ON ENnRE PARCEL Tq `\ \ 9 22J659 AC.x a956o 5F./BOOOO 5F. °12 LOTS ®53B°I2'10"E 61.81' `\ `\ % /9� k \ YIELD ON DEVELOPABLE AREA.12 LOTS x 0,40 =a LOTS ' ®535°I2'10'E 135.00' C� \� w�P'\\h w \_1y�P \S p ,] °C p \�p k` \\ Y7'DI \1 s. �\ `` C° CeeTAIN AREA5 HA101 h7 PREVELOPACFZVW LE A .22.1 5 AC x 0P0.4,4332 AC. MA%IMM DEVELOPABLE AREA .22.1649 AC x o�0°a.498a AC. ACTUAL PRESERVED AREA .IE9T00 AC.�\ (\a 1 \ \ It9 \ \ \ / A:.TUAL DEVELOPABLE AREA .5.1e'M AC. ENGINEERS CERTIFICATION °' SCALe:r°600 y p \'' G° S� WE Tfdabto Ctlffy1M nl faa. y�``d �\ ` ---_—\�/ �I��d� � `\� (/��r0 L (///D-�iZLGl.L l t••. J \- HOAAR G.YNaW6,T.NYS..NNO. 16ae3,���, F hea DOBII ep� Q ♦0 - Reaoludon No. a - \ I D0.GLA5 E AOAMS.NYS.PF.NO.8OBY1 ��J„(�S510Np� Su rvlsor,Town of SDudmld i 4pfM�\0^ \\\\ /' SURVEYOR'S CERTIFICATION I v�°Cfacd \ vn g / 1 / � NaWA � Tm w N .L9 No YOUMS, . 45899 .hI♦')7 FILE No.A-7 0 3 FG. VISION FILED MAR 05 2010 °�� �`` PETER HARBM O,l at Laurel,Town of Southold \ /FILED Suffolk County,New York 7cs �� Oi�� \\ `\— \ \ SKETCH PLAN .$. �° ` do 5/ County Tax Map ol.bcT 1000 sum°120 em,03 ux 11.11 Pascaw 7111011111 c�csuotxcouNn N0 Qpa nwjI•wrm b�.� \, MAP Y?f�°ARED MAY 27,2009 welYAtlanmaDW dYfad Re Of Revlelom m ec DATE In10Tmai1on i°p// L RRiOVEA LePROP 6QlgNH0U5es -tLY 29.DOO. 100' 7€ / WIS 2O09-OO'I6-5k tdLjvp I OF( B.xOMroIT YT ■.MONI®IT eG. 8•STKG S[t A.9TN2- � lJ\ 1 , - Revisions j,l , ,,��. ,";k?�:,"�,�,vi,&- ,`�-�/ -" �'_X �FV__ I ,/� �4, 4 %,Xv, 0" "/z' �6 1,X 06-25-96 1z 1, n 0, T8-2-9-6 io '�SEE SEC.'NO:'_. SEE SEC.NO.112 -21=96 XI 'SEE i .112 w -07-97 v. _iI, z P", g A 10 CH MAT LIN E A, LINE _:�8 9-9 A z 72 _4.......... 01-12-01 �z, SEE PCL, p "o W, 1112 IMM3-03 .7 I Q 1,� z C; 12-23-04 In -M_23�5 'X- �4 U5 -6T2—"6 T6:5-507 -:j5_715 0-9 (TOWNOFSOUTHOLO 'e- OWENTRIGH751 ...... 12-30-10 DEVEL 28.8A 10-02-13 u 2) -11-20 1� 02 �A VE (CPENSPAC%�$' &&',(kAfURZDRAJNAGEAREA 4 FARUVEtj RD 844 8.43 18A T (OPEN SPACE) 011 A <0 110 `1 50'0, 0\1 11.15 3.8A > ........... 18AA 11.16 (TOWNOFSOUTHOLO DEVELOPMENT RIGHTS)Y 0........... 7/ 11.14 34.4A _NT) (CONSERVATION EASEMF TOWN OF SOUTHOLD X zl�? -6 7002 1,�y ............ .. ................ . ............. �,SEE SEC.NO.124 POL.NO SM N91 Z02,i 0 L �D MEA �M=THS SMT— RWny,M IN 1� SECTION NO. WTIHI�T��%Lovwvm 01 TMTS; COUNTY OF SUFFOLK Q NOTICE K 2 '13 DISTRICT NO. 10QO E �L 9 ——CH_ A Q 12.1 NO.,123A MAINTENANCE E G F ------- Real PTOperty Tax S erVice Agency PLTEPAMOM SALE OR y D[SIRIBUTION OF ANY PORTION OF THE TOM OF SOUTHOLD E E m moo 120 71 R_ V U� 300 Center Drke,Ms erhead, T 11901 SUFFOLK COUNTY TAX IVAP IS PROHBJTED A (21) WITHOUT WRITTEN PeWISSION OF THE D sc� WASTMATCR_ REAL PROPERTY TAX SERVICE AGEWY. p 06 2 on u Re�jsiqns "Z, 7Il ',lk lq, -6,4, �41 SEE SEC.NO.112 XA, �,"SEE�SEC-lNWZ n z 08-26-96 IN, 11-21-96 10-07&97 V 0 I NE N 302.882 x- MATCH L Z 7 -08-99 12 IV N�, 04-06 -00 0 -01 Pallo", 01 p E .0, ,'1-03 C; 12-23-04 08-23-05 03-28-06 06-05-07 ....... 10-15-09 UTHOLO -OWNOFSO DEVELOPMENTPJGHTS 12�30�110 10-02-13 28.aA L) TI 20 T2--1120 T2-23 22 :70 Wo. ?L AVE. (OPEN EMC91 Y� 01? 8.43 FARMVEU RD, K)PEN SI'ACE) 1ro 10 0, or 71 0, & 01 03 11.16 18AA -7 ITOM OF SOUTHOLD DEVELOP19ENT PJGHrS)0 0 34AA 11.14 Y, TOWN OF SOUTHOLD (CONSERVATION EASEMENT) .......................... ............................................7., 3 z LINE SEE St:�.Nu.124 V NO EC No L 1— s SEll— 23 IN SECTION NO. �WffHW'NE MLLO�DISTMTS: COUNTY OF SUFFOLK (9) NOTICE K j12 =RJCt NO. 1000 E �001 A I—All 12.1A(d)or121A E MAINTENANCE'ALTERATON,SALE OR y G ------- 121M., Real PropertyTax Service Agency DISTRIBLMON OF ANY PORTION OF THE TOWN OF SOUT 10 w E HOLD E ——L— — --w— — C.*ull 300 C1-DrhT.N—bmtT 11901 SUFFOLK COUNTY TAX MAP IS PROHErIED 0600 120 N 71 WPHOUT WRITTEN PERMrSIGN OF THE A D (21) 10. p VILLAGE OF REAL PROPERTY TAX SERVICE AGENCY. Dr. Dominick J. Morreale 20 Highland Avenue E Head of the Harbor, NY 11780 Dr.dommorreale@optonline.net JUN n g 7022 (631) 838-8576 TOWN OF SMTHO"LD June 7, 2022 Ms. Amanda Nunemaker, Building Permits Examiner Town of Southold Southold, NY 11971 Re: Building Permit Application Daniel Harbes 5655 Aldrich Lane, Laurel NY SCTM# 1000120 3 Lots 11.WQ Dear Ms. Nunemaker: In accordance with our previous communication concerning the above noted parcel, enclosed please find the following: 1) An Application for Building Permit dated 6/3/22. This replaces the application dated 1/19/21 2) A survey of this property dated 12/22/20 and granted approval by The Suffolk County Department of Health (6/1/22) -3) A notice of Permit Conditions issued by the DOH 4) Four (4) copies, each sealed and signed by architect Frederick R. Weber, of the house and foundation plans. Please recall that this house was erected on anof'her property and has been moved to this location. The plans reflect placing the house on a new foundation 5) A photo of the house—currently on wheels and ready for placement on a new foundation. 6) Burger Custom Homes has been retained to complete the construction phase of the project and they will be sending you copies of their license, insurance etc. Should you need any further informatio lease do not hesitate to contact me. incere C ominir orreale, Ed.D. Cc: Daniel Harbes Southold Town Building Department P.O.Box 1179 Permit:#• 48051 . 53095 Main:Rd Southold,New York 11971 Permit Date: 7/11/2022 (631)765-1802 Expiration Date: . 1/10/2024. Parcel ID: 120.3-11.22 BUILDING PERMIT RENEWAL LETTER . Dated: 7/24/2024 Applicant: P&E LLC Location: 6025 Aldrich Ln.,Mattituck Work.Description: SINGLE,FAMILY'DWELLING Construct new foundation under existing(relocated)single family dwelling and construct porch additions as applied for,with SCHD approval. Additional certification-may be required for existing dwelling- A FEE OF $422.60 IS REQUIRED TO RENEW THIS BUILDING PERMIT.- Owner: P&E LLC Address: c/o Peter Harbes 1002 Bluff Dr N Baiting Hollow,NY 11933 The permit listed above has expired. No work is permitted or authorized beyond the expiration date. Please submit.the above fee made payable to the Town of Southold.Mail to the Town of Southold Building 'Department;P.O. Box 1179,.Southold,.New York 11971 THANK YOU, SOUTHOLD TOWN BUILDING DEPT. S.C.T.M. NO. DISTRICT: 1000 SECTION: 120 BLOCK: 3 LOT(S): 11.22 DWELLINGS I VACANT — DRAINAGE W/WELL WATER . — — — — OVER U.P. U.P. _T CL 49.8 ALDR I H---EANE L 46.2 / CL 46.0 E GE OF PAVEMENT I — S 31°42'10"E ! ]93.34' � 48 0 0/ F48 � � / f PROPOSED EL 47.6 �Smj (4) RED SUNSET MAP �. \ ► ALONG ALDRICH LAME F a 1 �` o Ln M. .'.' M / C5 10 8 / ® � _0 ''Lo LLI [1: 48 I= 100, ,Z \ ;. �� Lv ( I Q_ / i.± rn N LOT 2 tAj v► LOT 3 \ VACANT 150' CONC. / LOT 1 Moo>— VACANT 150 (49.0) ! BAY BAY (49.0) - 74 / ELEV. 47.6 OL BROWN 0.8 FR6POS ::::: ::::;: mrDRY LOAM WOOD ,'FRAME:DWELLING:;; :}; c� WEL STOOP f;;;(6 BEDROOMS):;`;`:;::r: / ! S BROWN M LOAMY SAND 1.9' — BILCO EXP f PROPOSED WATER LINE C.O. 0 BROWN 74.5' (49.0) 0'MIN S.T. L.P. i MEDIUM CONC. BAY (49.0) B'MIN / SP SAND SDOP PROPOSED & 6 BEDROOM t' GRAVEL Z.00c -}769.GAL S.T. 10'Ox 'EFFI.DEPTH 14.3' / (1)10'0x13'DEEP L.P. 1 \ 4 I I A 0 NO WATER I\ NOTE CHANGE — 17' a DEC.. 22, 2020 \ by Dept. of Health smiees /, x : �CHUK LS \ 152.7 !s Ld >- .z I �50� atul N �4" �► ` J / � ,�., 4r ---x.7.. r ep F = Q ., OWART MW OF Ma M� S r`p o I 1�lR1N17' R AFMOVALOF CONYMU ONKS A z = a w \ GLZ FAMILY RII SMENCE O Y m o 0 z - tiA7� -20 Z2 HS MW.NO. \ N 0 nCO a PROPOSED It�PRO g y n FOR mAXIMUM.OF BEDROOMS w W N up _THREE YsARS FROM DATE OF AmOvAL .:1 W p' 20' WIDE VEGETATED BUFFER Y J COMPRISED OF A DOUBLE ROW OF 6' O t w J E 51.0 EVERGREEN PLANTINGS AT 10' O.C. CN EL 50.7 N 31042'10"W LAND N/F OF P&E LLC• 193.34' RE — —22 TOWN OF SOUTHOLD DEVELOPMENT RIGHTS REVISED 03-30-22 22.17 ACRES (VACANT) 7HE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL LOCA77ONS SHOWN ARE FROM FIELD OBSERVA77ONS REVISED 03-10-22 VACANT AND OR DATA OBTAINED FROM'OTHERS NAVD88' ELEVATION DATUM. _—_ AREA:55,105.74 SQ.FT. or 1.27 ACRES 150 — UNAU7HORIZED AL7ERA77ON OR ADDITION TO 7HIS SURVEY IS A VIOLA77ON OF SEC77ON 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF 7HIS SURVEY MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL,RUN ONLY TO THE PERSON FOR WHOM 7HE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TU77ON - LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INS77TU770N, GUARANTEES ARE NOT 7RANSFERABLE. 774E OFFSETS OR DIMENSIONS SHOWN HEREON FROM 774E PROPERTY LINES TO 7HE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE 7HEREFORE 7HEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES, ADDITIONAL STRUCTURES OR AND 07HER IMPROVEMENTS EASEMENTS AND/OR SUBSURFACE STRUMRES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON 7HE PREMISES AT THE 77ME OF SURVEY' SURVEY OF:LOT 2 CERTIFIED TO: DANIEL HARBES; MAP ORPETER HARBES MAP TWO FILED:FEB. 14, 2022 No.12230 SITUATED AT-LAUREL TOWN OF:SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 FILE #220-190 SCALE:1 "=30' DATE: DEC. 22, 2020 PHONE (631)298-1588 FAX (631) 298-1586 N.Y.S. LISC. NO. 050882 Dd S.C;TM. H0. 6f 1RI6T: 1000 4C710N: 120 BLOCK: 3 LOT(S): 11.22 ' DWELLINGS I VACANT — DRAINAGE W/WELL WATER 150' - - ---. OVER 150'- - - - - - - - - - - - - - - - U.P. U.P. CL 49.8 ALDIMI�Y"LA N E6.0 _ EDGE OF PAVEMENT ` S 31042'10"E I 193,34' _- 48 Ar 1,444.27' X X X —�"'—X X X POST EXIST. FENCE / POST i l POST EL 47.6 PROPOSED IE (4) RED SUNSET MAPLES I� 48' ALONG ALDRICH LANE J z o / _o z Q _o A V / Il N / �_ I Q' a w I'�^^L in LJ 000 / I Z 4 0 48\ I O LOT 3 v I LOT 2 VACANT 150' 11 I WEGRESS INDOW ' LOT I WQ:Ls VACANT 150' (49.0) I (49.0) ELEV. 47.6 '� _ /�� 44.0' 74.9' / OL BROWN 0.8' FOUNDATION D LOAM o LOCATION WEL Cj SEPT. 10, 2022 / BROWN r TOP FND. 51.2 SM LOAMY SAND 1.9' EXP PROPOSED WATER LINE 44.0' C'0' 0�\� / BROWN 74.5 (49.0) 'O 10'MIN S.T. L.P. MEDIUM d (49.0) 8'MIN / SP SAND Pa0P0SID GRAVEL 6OROOM Srs7EM 14.3' 175D,f1�t,'%r 10104.5'EFF.D / (1)f0'O�t13�DEEP L. . NO WATER DEC.,°22, 2020 K, WOYCHUK LS L .1 50 Q) T. 7. iE S E P 2 8 2022 N T�4 i'a ur Ij PROPOSED \ WELLAqt _ 20' WIDE VEGETATED BUFFER COMPRISED OF A DOUBLE ROW OF 6' O : EVERGREEN PLANTINGS AT 10' O.C. CN EL 50.7 EL AIQ POST END. L.00, 0 -� 10-22 N31042'10"W LAND N/F OF Pic ',`LLC ' 1.93.34' ` �:,'�; ,"��TK;r — — ,� �•' ; ! I,Nri,1 l REVISED 04-25-22 TOWN OF SOUTHOLD DEVELOPMENT 16H.TS REVISED 03-30-22 22.17 ACRES"t VACANT THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL LOCA77ONS SHOWN ARE FROM FIELD OBSERVA77ONS REVISED 03-10-22 VACA'NT AND OR DATA OBTAINED FROM OTHERS Af EA.55,105.74� SQ.Ff. or 1.27 ACRES 150' ELEVA7)ON DATUM: NAVD88 UNAW-T74ORI,70 AL7E_kA77ON OR ADD177ON TO THIS SURVEY IS A VIOLATION OF,SEC,7701V�7209 OF THE NEW'WRK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY ?< yAP-NO.T,BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONS/DEJ?ED TO''BE A, VALIO TRUE COPY. GUARAN7FES INDICATED HEREON SHALL RUN �' ONL1Y TO THE PERSON FOR WHOM 7HE SURVEY IS PREPARED AND ON HIS BEHALF_TO THE 777LE,-COMPANY,.GOVERNMENTAL AGENCY AND LENDING INS77TU77ON 4IS7FQ,HEREON, AND TO THE ASSIGNEES OF 7HE LENDING INS77TU770N, GUARANTEES;ARE-NOT 'TRANSFERABLE.",, THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM 7HE PROPERTY LINES TO 7HE STRUCTURRE'S ARE FOR.A'>;SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE 7HE EREC77ON OF FENCES,IADDI770NAL.STRUC7URES OR AND OTHER IMPROVEMENTS EASEMENTS AI?D�R SUBSURFACE S7RUC1URES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS:PHYS/CALLY'EVIDENT ON 7HE PREMISES AT THE 77ME OF SURVEY `I SURVEY OF-LOT 2 . CERTI.FF IED T0: DANIEL HARBES; MAP ORIPETER HARSES MAP TWO •F & 14, 2022 No.12230 SI7UATEb Wr-LAUREL t f Towle of:9061-HOLD -i IONNETH M WOYCHUK LAND SURVEYING,, PLLCI SUFrOLK COUNTY, N8W YORK Professional Land Sut&eying and Design P.O. Bog 153 Aquebogue, New York 11931 r_ PHONE (631)298-1588 FAX (631) 298-1688 SCALE:1 ._-:30 DATA:I EC. 22, 2020 N.Y.S. LI5C. N0. 050882 S.C.T.M. NO. DISTRICT. 1000 SECTION: 120 BLOCK: 3 LOT(S): 11.22 L4 Pq #R-21 -0151 DWELLINGS I VACANT — DRAINAGE W/WELL WATER I 150' OVER - - -- - - -- - 150' -- --L- - - -- - - -- - - - - - - -- - - -- CL 49.8 �� ALDRICH LANE CL 46.2 CL 46.0 � EDGE OF PAVEMENT S 31.42'10"E 193.34' -Eft — W / x— — — >�--x—x x x x — F4R — x x � tx x x x � � x x—'`x— � POST OST — EXIST. FENCE POST POSED W (4) RED SUNSETMAPLES II \ Z ALONG ALDRICH LANE rn d' U, �� / 00 00 0 -° 00 00 fn Z' LOT O �R �I rn w \ Z, i LOT r WEL COVERED VACANT 150 CONC. LOT 7 IEGRESS srooP VACANT 150' WELLS 74.0' 75.0' / '.'::•2. STY FR,4ME:``:':N STOOOP :::`•DWELLING ?;:N gZ 37.5' 46.5' UW S.T. L.P. �— WATER LINE ..—.. C.O. / COVERED PORCH\0 22.5' 36' / : 6 BEDROOM SYSTEM / I 2000 GAL S.T. (WI (1)10'0x13'DEEP LP. / I \ I I � l I\ / I � � \ rn� I _ J I ^ SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES APPROVAL OF CONSTRUCTED WORKS FOR ASINGLE FAMILY RE5112ENCE R-21-0151 C� The sev+age dispose and`viater stspptyfe 1sves a"bis location have been N � inspected andior cerlified by this Department or other agencies and found 00 to be satisfactory FORA MAXIMUM OF s 8EDROOMS. O CRAiG tlt4EPPER,flE•CHIEF Ofte of Wasteviatei Management —I -----------— ----------------- ELL 20' WIDE VEGETATED BUFFER O COMPRISED OF A DOUBLE ROW OF 6' N EVERGREEN PLANTINGS AT 10' O.C. EL 50.7 EL 51.0 POST - - - - -- N 31042'10"w LAND N/F OF P&E LLC 193.34' TOWN OF SOUTHOLD DEVELOPMENT RIGHTS FINAL SURVEY 04-28-23 22.17 ACRES (VACANT) THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL LOCA71ONS SHOWN ARE FROM FIELD OBSERVA77ONS FND. LOC. 09-10-22 VACANT AND OR DATA OBTAINED FROM OTHERS. AREA: 55,105.74 SQ.FT. or 1 .27 ACRES 150' ELEVA77ON DATUM: NAVD88 UNAUTHORIZED ALTERATION OR ADD177ON TO THIS SURVEY IS A VIOLA77ON OF SECTION 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID 77?UE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS71TU77ON LISTED HEREON, AND TO 774E ASSIGNEES OF 774E LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO 774E STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE 774EREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECT70N OF FENCES, ADDITIONAL STRUCTURES OR AND 07HER IMPROVEMENTS EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARAN7EED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY SURVEY ORLOT 2 �� of NEw CERTIFIED TO: DANIEL HARBES; MAP OF:PETER HARBES MAP TWO P �N M 0��op FILED:FEB. 14, 2022 No.12230 Y� SITUATED AT:LAUREL r a TOWN OR SOUTHOLD 0 KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK �2s� osog82 Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 FILE #220-190 SCALE:1"=30' DATE: DEC. 22, 2020 N.Y.S. LISC. 050882 M PHONE (631)296-1588 FAX (631) 298-1588 O. n Fm_n1WE1L,MdA1N(D Indirect-Fired Water Heaters P L u s Series 2 ! SUBMITTAL SHEET JOB NAME LOCATION ARCH. / ENGR. WHOLESALER MECH. CONTRACTOR (� �] MODEL NO. k L�, M L 4 , 7 NOTES NOV 1 2 2024 Standard Equipment Aqua Plus Indirect-Fired Water Heaters: • Tank Models: 35,45,55,85 and 105 . • AHRI Certified@-The Trusted Mark of Performance Assurance • Factory Pressure Tested • Fully Passivated 316L Stainless Steel ��! # Tank and Coil Design k { • Precise Digital Thermostat— , Residential and Commercial Compatible • 2"Thick CFC-free Foam Insulation 1 Resilient Vinyl Jacket :. } Heavy Duty Poly Resin Top and Bottom t = Covers ' .--•.._-`. • Adjustable Feet for Uneven Floors - F` • 150 PSI Temperature and Pressure I Relief Valve Included { w d W M 1706_FRM_027_Aq PI us ACLQ,P LUs emm — Specifications RATINGS(WITH SOOF DOMESTIC WATER INLET AND STATED . . . . 200°F Boller Water 190°F Boiler Water 180°F Boiler Water Aqua Plus` Boiler Out 115OF 140°F Boiler Out 115°F 140°F Boiler Out 115OF 140°F Model MBH DHW GPH DHW GPH MBH DHW GPH DHW GPH MBH DHW GPH DHW GPH 35 170 337 223 170 311 202 150 284 181 45 190 363 243 170, 335 .222 ISO 307. 200 55 210 443 302 190 411 278 190 378 252 85 300 551 374 250 511 343 250 470 310 105 350 715 483� 350 662 442 300 608 400 DATA 35 45 55 85 105 DHW Side Storage(gal.) 29.7 39.9 541 81.6 110.9 Boiler Side Storage(gal.) 1.7 1.9 2.2 2.7 3.9 Recommended Flow Rates(GPM) 8 81 8 ^14 14 Head Loss-Boiler Side(ft.)d...�.w�. .�. 1.6 1.6 .� --�_4 1.6 5.4 7.1 Working Pressure(Tank)(psi) ,-150(maximum) Working Pressure(Coil)(Psi) 145(maximum) DHW Operating Temp(IF) � � 500F 160°F,Adjustable to 180017 Approx.Shipping Weight(lbs)� - � Y94 - 111 122�- 223 V 238 DIMENSIONS °� Dimensions(inches) 35 45 55 85 105 A 363/a 46'/4 60 59Ya 593/4 ,, . B 7% 7346 7la 103/a 14% m C 24 s 26� ^297/a 33'/ 413/a D; `— 217/e�^ +-2V/e µ 21% 26 30 E. � 73/e� __._._. 73/e 73/e .� 8�/e 9�/a ; 'F 28 3734a 513/e �- T-503/a 485/a' c DHW In/Out _ 3/4 in NPT 1 in NPT F Boiler Water In/Out 1 1 in NPT 1 in NPT' '71 piping required {-- 3 B Y ®_ n d: } > ® CONNECTIONS/ COMPONENTS: 1. Digital thermostat 4. Hot water outlet 2. Thermostat probe S. Boiler water inlet 3. T&P relief valve 6. Boiler'water outlet connection 7. Cold water inlet t In the Interest of continua/impfrovements in product and performance,Weil-McCain reserves the right to change specification without notice.For reference use only-see product manual for detailed informatron. Weil-McLain 1 500 Blaine Street, Michigan City, IN 46360-2388 1 www.weil-mclain.com ULTRA [M-N]WEIL-MiLAIND Series 4 Ultra Efficient Condensing Gas Boiler Series 4 1 80-399 MBH SUBMITTAL SHEET JOB NAME LOCATION ARCH./ENGR. WHOLESALER MECH. CONTRACTOR MODEL NO. NOTES a ` NOV 1 2 20244 Standard Equipment ,,,� � Boiler: U-Control Module: Optional Equipment: Cast aluminum block 0 3.5"LCD display Wall mounting kit • 30 PSI ASME relief valve • Three boiler priorities with multiple LWCO(w/harness and test button) • Drain valve preset system configurations Concentric Vent Kit • Stainless Steel Burner(80,105)with a Color-coded removable terminal blocks Condensate Neutralizer Kit woven steel fiber mesh(155,230,299 . Multiple boiler functionality Ultra Easy-Up Manifold &399) Alarm control functionality Water treatment—inhibitor&test kit • Direct spark ignition Ignition control Variable speed blower assembly High limit&modulating temp.control • Venturi mixing system with air silencer Low water protection • Negative pressure regulated gas valve Outdoor reset • 50 VA transformer . Ability to control any combination • Dual scale temp.&pressure gauge of 3 circulators • Outlet water temp.sensor • Inlet water temp.sensor Complete Jacket Assembly with: • Flue gas temp.sensor 0 Fully removable jacket front • Outdoor temp.sensor 0 Adjustable boiler legs • System water temp.sensors 0 On/off power switch • Condensate trap with drain tee Boiler Circulators: assembly • 1"Flanges(80&105)Taco 007 a Propane conversion orifice(all except • 1"&11/4"Flanges(155&230) model 80) Taco 0014 • 1'/4"&11/2'Flanges(299)Taco 0014 c • 11/a"&11/2"Flanges(399)Taco 0013 W M2106_FRM_027_AgPlus ULTRA Series 4 Specifications RATINGS Ultra 80 Ultra 105 Ultra 155 Ultra 230 Ultra 299 Ultra 399 CSA Input (Maximum) 80 MBH 105 MBH 155 MBH 230 MBH 299 MBH 399 MBH CSA Input"(Minimum) -" 16 MBH 21 MBH 31 MBH 46 MBH ' 62 MBH 80 MBH, DOE Heating Capacity 71 MBH 94 MBH 139 MBH 207 MBH 270 MBH *364 MBH Net AHRI_ 62 MBH �� '82 MBH �Y121YM13H 180 MBH A 235 MBH 317'M131-1 . DOE AFUE 93.5% 94% 94°r 94.1°l0 92.5% *91.7% *Combustion Efficiency DATA Ultra 80 Ultra 105 Ultra 155 Ultra 230° Ultra 299 Ultra 399 Vent Size 2"or 3" 2" or 3" 3" 3'fy or 4" 4" 4" Vent Material . y PVC/CPVCj PVC/CPVC/PVC/CPVC/PVC/CPVCj'PVC/CPVC/PVC/CPVC/ _PP PP PP PP PP PP Combustion Air Size 2"or 3" 2" or 3" 3" 3" or.41' 4" 4" Water Volume. e .69 Gal. .82 Gal _ IV Ga-L 1S7,Gal. 2. Gal. 2.1 Gal:' Approx. Shipping Weight 199 Lbs. 207 Lbs. 234 Lbs. 246'Lbs.-. 297 Lbs. 297 Lbs. DIMENSIONS Ultra 80 Ultra 105 Ultra 155 Ultra 230 ' Ultra 299 Ultra 399 Min. Recommended Pipe Size 1" 1" 1'/4" 11/4" 11/2" 1'/2" Supply,Tappings 1" 1" 1" 1" 1�/a" 1'l4" Return Tappings 1" 1" 1" 1"..` 1'/a" 1'/4" Gas Connection Size,- 1/2" 1/2" 1/a" ;/211 3!4"V 3/4" 221/8"(299/399) 2213/6" gas connection 19114e" �185/e" 173/,6"— ►�; water 21/e" —_Jll 2Y8" i supply $/4 �5'/4 connection qq 3 I i 23/e" / 31Y16" 6'/e" It-- - r 4311A6" i 473/4" air vent (299/399) ' inlet TOP 8 AS 0 (tDOE AN /4" 11/6 2Y41, 3 FI LEFT MIN MAX FRONT RIGHT *80-299 Models In the interest of continual improvements in product and performance,Weil-McLain reserves the right to change specification without notice.For reference use only-see product manual for detailed information. Weil-McLain 1 500 Blaine Street, Michigan City,IN 46360-2388 1 www.weii-mclain.com • • Fan Coil I' • turn to the experts Product Data = AIR HANDLER TECHNOLOGY AT ITS FINEST The FX4I)fan coils combine the raven technology of Carrier fan P gY coil units with Puron®, the environmentally sound refrigerant. These fan coils are loaded with popular features.Factory-installed, , z refrigerant-specific thermostatic expansion valves (TXV) are standard with these fan coil designs.The designs feature contoured condensate pans with rugged,drain connections,ensuring that little ' water is left in the unit at the end of the cooling duty cycle.The lack of standing condensate and corrosion free pans improves IAQ and product life,features homeowners appreciate. Standard features include grooved copper tubing and louvered aluminum fins.The large face areas of the refrigerant coils provide superior efficiency for high SEER and HSPF performance. Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners.Also units come with solid state fan controls, 1-in (25mm) thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils. Units can accommodate factory- and/or field-installed heaters from 3 to 30 f M It also should be noted that the unique cabinet design of these fan coils meet new stringent regulations for cabinet air leakage - a { " requirement of 2%cabinet leakage rate when tested at 1.0 inches of static pressure. The FX4I)fan coil is the Puron®refrigeration design loaded with popular features. It comes in a pre-painted (taupe metallic) galvanized steel casing and is shipped with a cleanable,permanent framed filter, and a factory-supplied power plug. ArmorCoat- ��' provides a tin plating of the indoor coil's copper hairpins. This r creates a barrier between the corrosion-causing elements and the coil. These fan coils utilize the latest in electronic commutation . g motor(ECM)technology through the use of high efficiency,X13, blower motors. � Y ' s l� U L ,i Al0009 N O V 1 2 2024 ` STANDARD FEATURES • High efficiency ECM(electronic commutating motor)X-13 motors-all sizes • Integrated motor controls have replaced integrated circuit board • Large,grooved tube,louvered fin coils • Efficient,quiet,time-tested blower housings and diffusers • Sturdy,drainable condensate pans • Cabinet construction features innovations designed to prevent cabinet sweating • Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements • Super-thick R-4.2 insulation with vapor barrier • Pre-painted galvanized steel cabinet(taupe metallic) • Cabinet design meets stringent regulations for 2%cabinet leakage rate when tested at 1.0 inches static pressure • Installation-flexible,multipoise units • Horizontal hanging provisions on cabinet • No tools required to service filter • Factory-supplied,cleanable and reusable filter • Newly improved filter rack area filter door insulation added for improved air seal • Factory-installed heater packages available(5-through 15-kW) • 3-through 30-kW accessory heaters-field installed • Factory-supplied power plug • Easy plug-in provisions for heater installation • Entry options for high and low voltage wiring hook-up • Simple,5-amp blade fuse(and a spare)to protect 40 VA transformer • Easy coil inspection(removable,snap-in plug on A-coil models) • Leak-preventing sweat connections • Modular cabinets available on 037 through 061 sizes. • Designed for manufactured housing applications. ADDITIONAL FEATURES FX4D • Puron®,environmentally sound refrigerant • Factory-installed Puron®refrigerant thermostatic expansion valves(TXV) • Factory-installed heater packages available • ArmorCoat- coil protection available 2 MODEL NUMBER NOMENCLATURE CARRIER FAN COILS 1 2 3 4 5 6 7 8 9 10 11 12 F X 4 D N B 0 1 9 0 0 0 Product Type Heating Size Fan Coil,Multipoise with Puron 000=No Heat 005=5kW Electrical 008=8 kW N-208/230v,1 ph,60 Hz 010=10kW 015=15kW Cabinet Style B-Modular Coil Coating F-Single Piece 0=Standard T=ArmorCoat " Capacity 019=18,000 025=24,000 031 =30,000 037=36,000 043=42,000 049=48,000 061 =60,000 ® Use of Ike d ea!Ceriified — mM Mark indicates a Nron.- ogafm.program c � us particip lion in the p ag am For veMraaon the en,v.-We ly sound Wrigemnl of ced""llon for individual , preclude,go to .hridimWory.org. LSD 9001 GMISAI Globol ArmorCoat 3 DIMENSIONS COIL SHIPPING WT SNIPPING WT UHT A B C D E F G H CONFIGURATION (LBSI (LBS) SLOPE 'A- NON TIN-COATED TIN-COATED FX4DNFO19 49 5/8' 17 5/8' 15 3/4' 15 5/8' 15 3/8' 23 1/8' 23 5/8' — IT, X — 122 122 FX4DNF025 49 5/8' 11 5/8' 15 3/4' 15 5/8' 15 3/8' 23 118' 23 5/8' — IT, X — 122 122 FX4DNF031 53 7/16' 21 1/8' 19 114' 19 1/8' 19'3/16' 26 15116' 21 112' — 19, X — 146 146 FX4DNF037 49 518' 21 1/8' 19 1/4' 19 1/8' 15 11/16' 23 7/16' 23 1/8' — — — X 157 157 FX40NF043 49 5/8' 21 118' 19 1/4' 19 1/8' 15 11/I6' 23 7116' 23 1/8' — — — X 157 157 F X4DNF049 53 7/16' 24 11/16' 22 Jl4• 22 11116' 19 1/2' 1 27 1/4' 26 15/16-1 185 i 185 FX40NFD61 159 3116'124 11/16'1 22 3/4' 122 11/16'1 25 114' 132 15/16' 32 5/8' 1 X 1 01 201 NOTE: NOTE:AL LON 2I'fAOtl FRONT I.SERIES DESIGNATION IS THE IIIH POSITION FOR SERVICE 01 UNIT PRODUCT NUMBER 2.ALL DIMENSIONS ARE IN'INCHES'UNLESS NOTED. UNIT CONNECTION SIZES SUCTION: 018 THRU 025 5/8' I.D. SWEAT 030 THRU 037 3/4' I.D. SWEAT CA THRU 061 - 118' I.D. SWEAT 22 1/16' LIQUID: 3/8' I.D. SWEAT CONDENSATE: 3/4' FPT 10 3/16' 11' 7/8' 2 1/8' 1. OUTLET AIR 3/4' ALTERNATE 7/8',1 3/32',2'DIA. K.O.'S NOTE: MODULAR FOR HIGH VOLTAGE UNITS WILL HAVE ALTERNATE POWER WIRING A TWO-PIECE 1/8'DI A. N.O. OPPOSITE SIDE CABINET FOR LOW VOLTAGE o CONTROL WIRING 7/8', 1 3/32' OPTIONAL FIELD CONVERTED 2• DIA. K.O.'S RIGHT SIDE RETURN OPENING FOR HIGH VOLTAGE (SLOPE COIL UNITS ONLTI POWER WIRING 1/8'DIA. N.O. A 1 1/2' 1 7/8' FOR LOW VOLTAGE h i CONTROL WIRING 1 15/16' 3/8'_1 1" c TOP VIEW 1 3/16' H MAX B 19' MODULARRUNITS 15I16' C DISCONNECT OR 1 3/4' CIRCUIT BREAKER LOCATION 0 o LOWER, CONTROL, o ACCESS ELECPANELIC 1 114'--�{ 19P13/16'—�{ 2 1/2' RIGHT SIDE VIEW INLET A[A OIL ACCESS PANEL INLET AIR 2 5/8' 4 11/16' 44F ANEL NG LIQUID LINE CONNECTIONLE TION LINE CONNECTION LIQUID LINE LINE 3 1/16 ONNECTION CONNECTION 10 7/16' e SUCTION LINE 0 o Q 10 3/4' CONNECTION 0 0 0�6• 0 9 1/2' 0 0 0 0 0 o 1• 5• OPENING PA R ACCESS PANEL SLOPE COIL DETAILS ACCESS PANEL CONFIG. FOR INLET AIR CONNECTION LOCATIONS SHOWN SLOPE COILS FOR UPFLOW OR HORIZ. DOWNFLOW OR HORIZ. FRONT VIEW LEFT APPLICATIONS RIGHT APPLICATIONS SHOWN WITH 'A' COIL DETAILS CONNECTION „A„ COILS LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS DOWNFLOW APPLICATIONS A10032 Fig.1- FX4D-English 4 DIMENSIONS (cont.) NOTES: SLOPE COIL CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN 'INCHES' UNLESS NOTED. AIRFLOW 2 3/16' TYP 1/i6' TIP. 1 12 PLACES). AIRFLOW (2 PL ACES) 1 } 1 . 3 114' •� • L 1• TYP. F o G PRIMARY DRAIN •© (2 PLACES)- 1 I/4' SECONDARY DRAIN SECONDARY DRAIN PRIMARY DRAIN ®o 1T 2 7/8' 1' TYP.J 7/16• TYP. (2 PLACES). (4 PLACES)- 1 114' \ 2 9/16' DOWNFLOW 2 3/16' 3 1/4' (FIELD CONVERTED) TIP, (2 PLACES)- UPFLOW PRIMARY DRAIN (AS SHIPPED) SECONDARY DRAIN r5116' PRIMARY DRAIN TYP. 1 73/16' 1 SECONDARY DAA IN TYP. p -E 0 1 5/8, 'cd i 1 1l4' ® ° I 5/16' 5116- ® 1.7YP. TYP. 1 12' • 114' TYP. 7/8' 1/2' 1 13116' F TYP.- TYP.- 1 5/8' TIP 7/8' 2 7/8' HORIZ. RIGHT TYP'' HORIZ: LEFT 5' (FIELD CONVERTED) (AS SHIPPED) HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, A-C 0 I L AND DACN OF CABINET. IN CABINET BOTTOM. HOLES PAOVI DED .136' DIA. HORIZONTAL HANGING HARDWARE TO 8E FIELD SUPPLIED. PRIMARY DRAIN 1 13/16' SECONDARY DRAIN TYPE O O AIRFLOW 2 3/16' TYP. O O f 7/16' TYP. I 12 PLACES)p 16 e AIRFLOW !4 PLACES) 1 .� •• TYPE 1 3116 1 1/2' •S 7l8' TYP S/16'E t ' —� TYPE 7 T/8' '� (2 PLACES) F d 3/4' 'O 0 G HORIZ. LEFT SECONDARY DRAIN 31/16' O SECONDARY DRAIN (AS SHIPPED) PRIMARY DRAIN AIXAAY DRAIN PRIMARY DRAIN- 5/1 TYP..6' SECONDARI DRAIN r O• T O ° r 1' TYP O O �, I I2 PLACESU 1 3' 118 �TT 112' T/16' TYP, (4 PLACES) El L L 0 1-'r 3 1/16' 2 11/16' DOWNFLOW �7/e 1 3/I6' 112'J 2 3116' 4 3/4' 7 7/8- TYP. TIP. (FIELD CONVERTED) (2 PLACES)- 1 13TIP, 718' U P F L OW HORIZ. RIGHT TYP.. (AS SHIPPED) (FIELD CONVERTED) A10033 Fig.2- FX4D-English 5 DIMENSIONS (cont.) uN r A 8 C D E F G Hk482.6 comr icuecr o� SHIPPING WT SHIPPING Wi SLOPE 'A' NON TIN-COATED TIN-COATED FX4DNF019 1260.5 447.1 400.0 396.9 390.5 587.4 600.1 - % - 55.3 55.3 FX40NF025 1260.5 447.7 400.0 396.9 390.5 587.4 600.1 - X - 55.3 55.3 FX4DNF031 1357.3 536.6 489.0 485.8 487.4 684.2 698.5 - X - 66.2 66.2 FX4DNF031 1260.5 536.6 489.0 485.8 398.5 595.3 587.4 - - X 71.2 71.2 FX4DNF043 1260.5 536.6 489.0 485.8 398.5 595.3 587.4 - - X 71.2 71.2 F%4DNF 049 1351.3 627.1 577.8 576.3 495.3 692.2 684.2 - - - % 84.1 84.1 F X4 DNF061 1503.4 1 627.1 577.8 576.3 641.4 836.E 1 828.7 1 - - - % 91.2 91.2 NOTE: NOTE: ALLOW 533.4 FROM FRONT 1. SERIES DESIGNATION IS THE 14TH POSITION UNIT CONNECTION SIZES FOR SERVICE OF UNIT PRODUCT NUMBER 2. ALL DIMENSIONS ARE IN 'MM' UNLESS NOTED. SUCTION: 018 THAU 025 - 15.88 I.D. SWEAT 030 THAU 037 - 19.05 I.D. SWEAT 042 THAU 061 22.23 I.D. SWEAT 560.4 LIQUID: 9.53 I.D. SWEAT CONDENSATE: 19.0 FPT 258.8 279.4 22.2 54.0 25.4 OUTLET AIR 19.0 ALTERNATE 22.23. 27.78. 50.80 DIA. X.O.-S FOA HIGH VOLTAGE NOTE: NODULAR ALTERNATE POWER WIRING UNITS WILL HAVE 22.23 DIA. K.O. OPPOSITE SIDE A TWO-PIECE FOR LOW VOLTAGE CABINET CONTROL WIRING OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING I SLOPE COIL UNITS ONLY) A 38.1 22.23, 27.78 50.80 DIA. K.O.'S FOR HIGH VOLTAGE POWER MIRING 22.23 DIA. K.O. 47.6 FOR LOW VOLTAGE CONTROL WIRING 30.2-+{ MAX H 4 25.4 I R TOP VIEW 34.9 482.6 MODULAR UNITS 44.4 23.8 �--C-� I I OPENING 31.8-+{ ice---' 5032 63.5 I RCSCONNECT UITBR OA CI EAKER RIGHT SIDE VIEW LOCATION o INLET AIR LOWER, CONTROL, X ELECTRIC HEATER ACCESS PANEL OANELIL ACCESS P INLET AIR 66.1 119.1 FITTING LIOUID LINE CONNECTION E Q PANEL LIQUID LINE SUCTION LINE CONNECTION CONNECTION LIOUID LINE 77.8 CONNECTION o o L 265.1 O ° Q SUCTION LINE g 273.0 CONNECTION O Q o 2 2d1.3 a CEO) o ra%o 0 o 27.0 FILTER ACCESS 1 S OPENING PANEL 25.4 D ACCESS PANEL CONFIG. FOR SLOPE COIL DETAILS SLOPE COILS INLET AIR CONNECTION LOCATIONS SHOWN DOWNFLOW OR HORIZ. FOR UPFLOW OR HORIZ. RIGHT APPLICATIONS FRONT VIEW LEFT APPLICATIONS AND SHOWN WITH 'A'COIL DETAILS CONNECTION °A° COILS LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS DOWNFLOW APPLICATIONS A10034 Fig.3- FX4D-Metric 6 DIMENSIONS (cont.) NOTES: S LOP E COIL 11.1 TYP. 1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN'MM' UNLESS NOTED. AIRFLOW 55.6 TYP. f (2 AIRFLOW (2 PLACES)- 1 1 TT PLACES)- I 1 T kl TT 1`25.4 TYP. 82.6 I PRIMARY DRAIN (2 PLACES)- F o G SECONDARY DRAIN J1.8 SECONDARY DRAIN ®o PRIMARY DRAIN 73.0 25.4 TIP. 11.1 YP. 31.8 65.1 (2 PLACES)- (4 PLACETS)- 55.6TIP 82.6 DOWNFLOW (2 PLACESIr UPFLOW (FIELD CONVERTED) (AS SHIPPED) PRIMARY DAAI SECONDARY DAAIH PRIMARY DRAIN 16.0 8.0 SECONDARY DRAIN 7YP.r TIP,- Q 31.8 11.3 1 8r rP.0 . 12.7 12.7 46.0 54.0 .8 TYP.- TYP?� TIP.- J1 11.3 TIP.- L F 22.2 73.0 HORIZ. RIGHT TYP.- HORIZ. LEFT 127.0 9 (FIELD CONVERTED) (AS SHIPPED) A-COIL r HORIZONTAL MOUNT LOCATIONS • DIMPLES PROVIDED IN TOP PANEL. AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED 3.45 DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. PRIMARY DRAIN 46.0 SECONDARY DRAIN TYP- . O ff- I L AIRFLOW 55.6 TIP. O f 11.1 TIP. (2 PLACES)- 2 © ® O I AIRFLOW �114 PLACES) T TYP• 38.1 149.2 �- 22.2 J0.2 TYP- 25.4 TYP. U O 0� G TYP- 200.0 (2 PLACES) SECONDARY DRAIN HORIZ. LEFT SECONDARY DRAI (AS SHIPPED) PRIMARY DRAIN PRIMARY RIMARY DRAIN SECONDARY DRAIN O r Tip'.. 25 1 TYP 1 0 O l2 PLACES)- O O 79.4 O 11.1 TYP, l4 PLACES)- 38.1 77.8 68.3 DOWNFLOW y 55.6r 12o.6 149.2 T TIP. (FIELD CONVERTED) 30.2 12.7J (2PLACES)- 46.0 z0o.0 TIP.- UPFLOW TYP. zz 2 (AS SHIPPED) HORIZ. RIGHT ITP,r (FIELD CONVERTED) AT 0035 Fig.4-FX4D-Metric PHYSICAL DATA FACTORY NOMINAL COOLING DIMENSIONS SHIPPING ORDERING NO. INSTALLED CAPACITY(Btuh) Height Width Depth WEIGHT HEAT(kW) FX4DNF0190,T)00 - 495/8-in 175/8-in 22-1/16-in 1221b FX4DNF019005 5 18,000 1261mm 447mm 560mm 55kg FX4DNF025(0,T)00 - 495/8-in 175/8-in 22-1/16-in 1221b FX4DNF025005 5 24,000 1261mm 447mm 560mm 55kg FX4DNF031(0,T)00 - 537/16-in 211/8-in 22-1/16-in 1461b FX4DNF031008 8 30,000 1357mm 536mm 560mm 66 kg FX4DNF037(0,T)00 - 495/8-in 211/8-in 22-1/16-in 157lb FX4DNF037010 10 36,000 1261mm 536mm 560mm 71 kg FX4DNF043(0,T)00 - 495/8-in 211/8-in 22-1/16-in 1571b FX4DNF043010 10 42,000 1260mm 536mm 560mm 71 kg FX4DNF049(0,T)00 - 48,000 537/16-in 2411/16-in 22-1/16-in 1851b FX4DNF049010 10 1357mm 627mm 560mm 84 kg FX4DNF061(0,T)00 - 593/16-in 2411/16-in 22-1/16-in 2011b FX4DNF061010 10 60,000 1503mm 627mm 560mm 91 kg FX4DNF061015 15 FX4DNB031T00 - 30,000 53 7/16-in 21 1/8-in 22-1/16-in 1461b 1357mm 536mm 560mm 66 kg FX4DNB037T00 - 36,000 537/16-in 211/8-in 22-1/16-in 1751b 1357mm 536mm 560mm 79kg FX4DNB043T00 - 42,000 537/16-in 211/8-in 22-1/16-in 1751b 1357mm 536mm 560mm 79kg FX4DNB049T00 - 48,000 537/16-in 2411/16-in 22-1/16-in 1851b 1357mm 627mm 560mm 84 kg FX4DNB061T00 - 60,000 593/16-in 2411/16-in 22-1/16-in 2011b 1503mm 627mm 560mm 91 kg 6th digit: B-Modular cabinet,F-Single piece cabinet 10th digit: 0-Standard copper coil,T-ArmorCoat- SPECIFICATIONS COIL- Puron@ Refrigerant TXV-factory installed hard-shutoff,bi-flow type for heat pump application Metering Device TXV 2 ton 3 ton 4 ton Rows/Fins Per In. 3/14.5 Face Area(Sq.Ft.) 2.97 1 3.46 4.45 5.93 1 7.42 Configuration Slope A FAN CFM(Nominal) 600 800 1000 1200 1400 1600 2000 Motor Type(ECM) X-13 X-13 X-13 X-13 X-13 X-13 X-13 Motor Hp 1/3 1/3 1/2 1/2 1/2 3/4 3/4 FILTER 21-1/2-in/546 mm X 16-3/8-in/417 mm 19-7/8-in/505 mm 23-5/16-in/585 mm CABINETCONFIGURATION OPTIONS 1-pc 1-pc/Modular 8 PERFORMANCE DATA AIRFLOW PERFORMANCE (CFM) MODEL& BLOWER 0.10 0.20 0.30 0.40 0.50 0.60 SIZE SPEED Tap 5 776° 745. " 696" "'. 660 609 572 Tap 4 683A 644 589 548 494 461 FX4D 019 Tap 3 683 644 589 548 494 461 Tap 2 631 563 500 443 409 361 Tap 625 524 457 417 367 319 Tap 5 956 920 891 851 816 780 Tap 4 825 795 757 722 674 634 FX4D 025 Tap 3 825 795 757 722 674 634 Tap 2 726 695 635 598 543 509 Tap 1 631 563 500 443 409 361 Tap 5 i189" Y15 1104 1 1050 1003 959 Tap 4 1041 998 944 886 837 772 FX41)031 Tap 3 1041 998 944 886 837 772 ` Tap 2 924 876 817 752 704 660 Tap 1 77.9- 693 628 571 526 .47.6 Tap 5 !,1363 1332 1294 1253 1207 1157 Tap 4 1237 1206 1160 1121 1070 1013 FX4D 037 Tap 3 1237 1206 1160 1121 1070 1013 Tap 2 1095 1058 1007 951 888 824 Tap 1014 885 773 673 609 549 Tap 5 1519 1490 1454 1419 1379 1332 Tap 4 1437 1403 1366 1333 1294 1245 FX4D 043 Tap 3 1437 1403 1366 1333 1294 1245 Tap 2 1257 1226 1191 1141 109Q, 1033 Tap 1 1237 1206 1160 1121 1070 1013 Tap 5 1757 1725 1693 1653 1614 1576 Tap 4 1664 1626 1593 1552 1517 1477 FX4D 049 Tap 3 1664 1626 1593 1552 1517 1477 Tap 2 1459 1420 1379 1336 1298 1259 Tap 1301 1241 1195 1150 1102 1039 Tap 5 2030 1995 1961 1927 1888 1842 Tap 4 1811 1775 1740 1703 1664 1613 FX4D 061 Tap 3 1811 1775 1740 1703 1664 1613 Tap 2 1665 1632 1593 1556 1507 1453 Tap 1462 1418 1371 1327 1278 1228 -Airflow outside 450 cfm/ton. NOTES: 1. Airflow based upon dry coil at 230v with factory-approved filter and electric heater(2 element heater sizes 018 through 037,3 element heater sizes 043 through 061). 2. Airflow at 208 volts is approximately the same as 230 volts because the X-13 motor is a constant torque motor.The torque doesn't drop off at the speeds the motor operates. 3. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in we. Horizontal applications of 043-061 sizes must have supply static greater than 0.20 in we. 4. Airflow above 400 cfm/ton on 049-061 size could result in condensate blowing off coil or splashing out of drain pan. 9 PERFORMANCE DATA (cont.) GROSS COOLING CAPACITIES (MBH) - PURONO REFRIGERANT UNIT INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR(°F/°C) SIZE AIR 35/2 40/4 45/7 1 50/10 55/13 CFM EWB TC SHC BF TC SHC BF TC I SHC BF I TC SHC BF TC SHC BF 72/22 36 19 0.00 33 17 0.00 28 15 0.00 24 13 0.00 19 11 0.01 525 67/19 29 19 0.01 26 17 0.01 22 15 0.02 17 13 0.02 12 10 0.02 62/17 23 19 0.02 20 17 0.02 16 15 0.02 12 12 0.07 10 10 0.24 FX4D 72/22 40 21 0.00 36 19 0.00 32 17 0.00 27 14 0.01 21 12 0.02 019 600 67/19 33 21 0.02 29 19 0.02 24 17 0.02 19 14 0.02 13 12 0.03 62/17 26 21 0.02 22 19 0.02 17 17 0.03 13 13 0.08 11 11 0.25 72/22 44 23 0.00 1 40 21 0.00 35 18 0.00 29 16 0.02 23 13 0.02 675 67/19 36 23 0.02 32 21 0.03 26 18 0.03 21 16 0.03 15 13 0.03 62/17 29 24 0.03 24 21 0.03 19 19 1 0.04 15 15 0.10 12 12 0.26 72/22 1 48 25 0.00 43 22 0.00 37 19 0.00 31 17 0.02 25 14 0.03 700 67/19 39 25 0.03 34 22 0.03 28 20 .0.03 22 17 0.03 16 14 0.04 62/17 31 25 0.03 26 23 0.03 20 20 0.04 16 16 0.10 13 13 0.26 FX4D 72/22 53 27 0.00 47 24 0.00 41 21 0.01 35 18 0.03 27 15 0.04 025 800 67/19 43 28 0.04 37 25 0.04 31 22 0.04 25 19 0.04 17 16 0.05 62/17 34 28 0.04 1 29 25 0.04 23 22 0.05 18 18 0.12 15 15 0.28 72/22 57 30 0.00 51 27 0.00 45 23 0.03 38 20 0.04 30 17 0.05 900 67/19 47 30 0.05 41 27 0.05 34 24 0.05 27 21 0.05 19 17 0.06 62/17 37 31 0.05 31 28 0.05 25 24 0.06 20 20 0.14 16 16 0.29 72/22 59 30 0.00 53 27 0.00' 46 '24 0.01 38 20 0.02 1 30 17" 0.03 875 67119 .48 31 0.03 42 28 0.03 35` 24 a 0.04 27 21 0.04 19 17 0;04, -62/17 38 31 0:04 32' 28, ,0.04 25. 24 0.04 '20 20 . 0.11 16 16 0.27 FX4D 72/22. 65 33 0.00 58 30 0 00 51. 26 0.02 42 23 -0.04, 33 19 0.04 031 1000 67/•19 .53`. 34 0.04 46 . 31 0.04 38 27 0.05 30 23 0.05 21 19. 0.05 62/17 42 35 0.05 35 31 0.05 28- 27'.. 0.06 22, 22 0.13 18 18, 0.29 72/22. 71 36 0.00 63' 33 0.00 55' 29 0.03 46 • •25 0.05 36 -20 -0.05 -11225 67/19 58 37 0.05. 50 33 0.05 42 29 0.06 33, 25 0.06 23 21 0.07 62/17 46 38 0,06 38 34 0.06 30' 30 0.07 24 _ 24 0.15 20 20 0.30 72/22 67 36 0.00 1 60 32 0.00 52 28 0.00 44 24 0.02 35 20 0.03 1050 67/19 54 37 0.03 47 33 0.03 40 29 0.03 31 25 0.03 22 20 0.04 62/17 43 37 0.03 36 33 0.03 29 29 0.04 22 22 0.10 18 18 0.26 FX41D 72/22 74 40 0.00 66 36 0.00 58 1 31 0.01 48 27 0.03 38 22 0.04 037 1200 67/19 60 41 0.04 52 36 0.04 44 32 0.04 35 27 0.04 24 23 0.05 62/17 48 41 0.04 40 37 0.04 32 32 0.05 25 25 0.12 21 21 0.28 72/22 81 43 0.00 72 39 0.00 63 34 0.03 53 30 0.04 41 25 0.05 1350 67/19 66 45 0.05 57 40 0.05 48 35 0.05 38 30 0.05 27 25 0.06 62/17 52 46 0.05 44 41 0.05 35 36 0.06 28 28 0.14 1 23 23 0.29 72/22 79 41 0.00 -71 37, 0.00- 62 33 0.02 52, 28. 0.03 41 23 0.04 1225 67/19 64' 42 0.04 56 38 0.04 47 °33 0.04 : 37` 29 0.04 26 24 -- ,:0.05 62:/17 51' 43 0.04. 43 38` 0.04 34 34 0.05 -27 27 0.12 22 22 0.28 FX4D 72/22 87 �' 46 0.00- 78 • 41 0.00 68 36 0.0357 31 0.04 , 45 .26 0.05 043 1400' 67/19 .71 _, 47 0.05 62 42 _ 0,05 52;. ,37 0.05 41 32 0.05 , 29 26 0.06 62 117 -56 48 0.06 47 43 0.06 38 38 '0.06 30 30 0.14 25 25 0.29. 72/22' 95 50 0.00 85 45' 0.00, 74, 39 0.04 62. " 34 0.05. 48 28 0.06 1575 67/19 77 51 0.06 67 46 0.06, 56 40 0,06, 44 35, 0.07 31 ' 29 0.07 62/17 61 52 0.07 51 47-- 0.07 „-41•`, 41 0.08 33 33 0.17 27 27 0.31 72/22 90 48 0.00 81 43 0.00 71 38 0.00 59 32 0.02 47 27 0.03 1400 67/19 73 49 0.03 64 44 0.03 54 38 0.03 42 33 0.03 30 27 0.04 62/17 58 49 0.03 49 44 0.03 39 39 0.04 30 30 0.10 25 25 0.26 FX4D 72/22 100 1 53 0.00 89 48 0.00 78 42 0.01 65 36 0.03 51 30 0.04 049 1600 67/19 81 54 0.04 71 48 0.04 59 43 0.04 47 36 0.04 33 30 0.05 62/17 65 55 1 0.04 54 49 1 0.04 43 43 0.05 34 34 0.12 28 28 0.28 72/22 109 58 0.00 97 52 0.00 85 46 0.03 71 39 0.04 56 33 0.05 1800 67/19 89 59 0.05 77 53 0.05 65 47 0.05 51 40 0.05 36 33 0.06 62/17 70 60 0.05 59 54 0.05 47 48 0.06 37 37 0.14 31 31 0.29 72/22 109 57 0.00 98 51 0.00 86 45 0.00 73 39 0.01 58 32 0.02 1600 67/19 89 58 0.02 78 52 0.02 66 46 0.02 1 52 39 0.03 37 33 0.03 62/17 71 59 0.03 60 52 0.03 48 46 0.03 37 37 0.09 31 31 0.24 FX4D 72/22 117 61 0.00 105 55 0.00 92 48 0.01 78 41 0.02 62 35 0.02 061 1750 67/19 95 62 0.03 84 56 0.03 70 49 0.03 56 42 0.03 40 35 0.03 62/17 76 63 0.03 64 56 0.03 51 50 0.04 40 40 0.10 33 33 0.25 72/22 129 67 1 0.00 116 60 0.00 102 53 0.02 86 46 0.03 68 38 0.03 2000 67/19 105 69 0.04 92 62 0.04 78 54 0.04 62 47 0.04 44 39 0.05 62/17 84 70 1 0.04 1 71 63 1 0.04 57 55 1 0.05 45 45 0.12 37 37 0.27 See Notes following table. 10 PERFORMANCE DATA (cont) CFM-Cubic Ft per Minute EWB-Entering Wet Bulb OF(°C) LWB-Leaving Wet Bulb OF(°C) TC Gross Cooling Capacity 1000 Btuh SHC-Gross Sensible Capacity 1000 BF-Bypass Factor MBH-1000 Btuh Btuh NOTES: 1. Contact manufacturer for cooling capacities at conditions SHC CORRECTION FACTOR other than shown in table. ENTERING AIR DRY-BULB TEMPERATURE(OF) 2. Formulas: 79 78 77 76 75 Under 75 Leaving db=entering db-sensible heat car). 81 82 83 84 85 Over 85 1.09 x CFM BYPASS ENTERING AIR DRY-BULB TEMPERATURE(°C) Leaving wb =wb corresponding to enthalpy of air leaving FACTOR 26 25 25 24 24 Under 7 coil(hlwb) 5 hlwb=hewb-total capacity(Btuh) 27 28 28 29 29 Over 85 4.5 x CFM Correction Factor where hewb=enthalpy of air entering coil.Direct interpola- 0.10 .098 1.96 2.94 3.92 4.91 Use tion is permissible.Do not extrapolate. 0.20 0.87 1.74 2.62 3.49 4.36 formula shown 3. SHC is based on 80°F(27°C)db temperature of air enter- 0.30 0.76 1.53 2.29 3.05 3.82 below ing coil. Below 80°F(27°C)db,subtract(Correction Fact- Interpolation is permissible. _ or x CFM)from SHC.Above 80°F (27°C)db, add(Cor- Correction Factor=1.09 x(1 -BF)x(db-80) rection Factor x CFM)to SHC. 4. Bypass Factor= 0 indicates no psychometric solution.Use bypass factor of next lower EWB for approximation. MINIMUM CFM AND MOTOR SPEED SELECTION FAN COIL SIZES HEATER kW FX 3 5 8 9 10 15 18 20 24 30 019 525 525 525 — 600* — — — — — 025 700 700 700 — 700 775* — — — — 031' — 875 875 - 875 875 - 1060* — — 037 — 1050 970 970 970 920 — 1040 — — 043 — 1225 1225 1225 1225 1225 1225 — 049 — — 1400 1400 1400 1 1400 1 1400 1400 1400 1400 061 — — 1 1750 1 1750 1 1750 1 1750 1 1750 1 1750 1750 1750 * Indicates medium speed(blue).Al other motor speeds at low tap. AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP(in wc) AT INDICATED AIRFLOW(DRY-TO-WET COIL) FX CFM SIZE 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1 1600 1700 1800 1900 2000 019 0.034 0.049 0.063 -- -- -- -- -- -- -- -- -- -- -- -- -- 025 0.016 0.027 0.038 0.049 0.059 -- -- -- -- -- -- -- -- -- -- -- 031 -- -- - --- 0.049 0.059 0.070 0.080. -- -- -- _ -= -- =- -- -- -- 037 -- -- -- -- -- 0.055 0.064 0.073 0.081 -- -- -- -- -- -- -- 043 - -- -- -- -- -- ` 0.049 " 0.056 0.063 0.070 - - -- -- 049 -- -- - -- -- -- -- -- -- 0.038 0.043 0.049 0.054 1 0.059 -- -- 061 -- -- -- -- -- -- -- -- -- -- -- 0.027 0.031 1 0.035 0.039 0.043 11 PERFORMANCE DATA (cont) FACTORY-INSTALLED FILTER STATIC PRESSURE DROP(in wc) UNIT SIZE CFM FX4D 400 600 800 1000 1200 1400 1600 1800 2000 019,025 0.012 0.022 0.048 0.072 - - - - - 031,037,043 - - 0.036 0.051 0.07 0.092 0.12 - 7 049,061 - - - - - 0.073 0.086 0.105 0.13 ELECTRIC HEATER STATIC PRESSURE DROP(in wc) 019-037 043-061 HEATER EXTERNAL STATIC HEATER EXTERNAL STATIC ELEMENTS kW PRESSURE ELEMENTS KW PRESSURE CORRECTION CORRECTION 0 0 +.02 0 0 +.04 1 3,5 +.01 2 8,10 +.02 2 8,10 0 3 9,15 0 3 9,15 -.02 4 20 -.02 4 20 -.04 6 18,24,30 -.10 The airflow performance data was developed using fan coils with 10-kW electric heaters(2 elements)in the 019 through 037 size units and 15-kW heaters(3 elements)in the 043through 061 size units.For fan coils with heaters of a different number of elements,the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. ACCESSORY ELECTRIC HEATERS HEATER kW @ VOLTS/ STAGES(kW INTERNAL FAN COIL SIZE HEATING CAP.** PART NO. 240V PH OPERATING) CIRCUIT USED WITH @ 230V PROTECTION KFCEH0401NO3 3 230/1 3 None 018-024 9,400 KFCEH0501 N05 5 230/1 5 None 018-060 15,700 KFCEHO801N08 8 230/1 8 None 018-060 25,100 KFCEH0901N10 10 230/1 10 None 018-060 31,400 KFCEH3201 F20 20 230/1 5,20 Fuse$ 030-060 62,800 KFCEH1601315 15 230/3 5,15 None 036-060 47,100 KFCEH2O01318 18 230/3 6,12,18 None 042-060 56,500 KFCEH3401 F24 24 230/3* 8,16,24 Fuse 048,060 78,300 KFCEH3501 F30 30 230/3* 10,20,30 Fuse 048,060 94,100 KFCEH2401C05 5 230/1 5 Circuit Breaker 018-060 15,700 KFCEH2501C08 8 230/1 8 Circuit Breaker 018-060 25,100 KFCEH2601C10 10 230/1 10 Circuit Breaker 018-060 31,400 KFCEH3301C20 20 230/1 5,20 Circuit Breaker 030-060 62,800 KFCEH2901 N09 9 230/1 t 3,9 None 036-060 28,200 KFCEH3001 F15 15 230/1 5,15 1 Fuse$ 024-060 47,100 KFCEH3101C15 15 230/1 5,15 1 Circuit Breaker 624-060 47,100 * Field convertible to 1 phase. t Field convertible to 3 phase. $ Single point wiring kit required for these heaters in Canada. ** Blower Motor heat not included. ESTIMATED SOUND POWER LEVEL WBA) CONDITIONS OCTAVE BAND CENTER FREQUENCY* UNIT SIZE Ext Static FX CFM pressure 63 125 250 500 1000 2000 4000 019 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 025 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 031 1000 0.25 67.0 , 63.0 59.0` 56.0 54.0 52.0 48.0 037 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 043 1400 0.25 68.4 64.4 60.4 57.4 55.4 '53.4 49.4 049 1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0 061 2000 0.25 70.0 66.0 62.0 59.0 57.0 55.0 51.0 * Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems&Applications Handbook,Chapter 52, p.52.7. 12 ELECTRICAL DATA FOR UNITS WITH FACTORY-INSTALLED HEAT SINGLE CIRCUIT DUAL CIRCUIT FX4DNF MTR MTR VOLTS/PH/ HEAT PACK INSTALLED Heater Amps MCA MOCP Amps MCA MOCP MODEL NO. HP FLA HZ MKFCEH Amps MCA MOCP L1/L2 L1/L2 L1/L2 L3/L4 L3/L4 L3/L4 019005 1/3 2.8 208/230/1/60 0501 N05 18.1/20.0 26.1/28.5 30/30 N/A N/A N/A N/A N/A N/A 025005 1/3 2.8 208/230/1/60 0501N05 18.1/20.0 26.1/28.5 30/30 N/A N/A N/A N/A N/A N/A 031008 1/2 4.1 208/230/1/60 0801N08 28.9/32.0 41.3/45.2 45/50 N/A N/A N/A N/A N/A N/A 037010 1/2 4.1 208/230/1/60 0901 N10 36.2/40.0 50.4/55.1 60/60 N/A N/A N/A N/A N/A N/A 043010 1/2 4.1 208/230/1/60 0901N10 36.2/40.0 50.4/55.1 60/60 N/A N/A N/A N/A N/A N/A 049010 3/4 6.0 208/230/1/60 0901 N10 36.2/40.0 52.8/57.5 60/60 N/A N/A N/A N/A N/A N/A 061010 3/4 6.0 208/230/1/60 0901 N10 36.2/40.0 52.8/57.5 60/60 N/A N/A N/A N/A N/A N/A 061(0,T)015 3/4 6.0 208/230/1/60 1501 F15 54.2/59.9 75.3/82.4 80/90 36.2/40.0 52.8/57.5 60/60 18.1/20.0 22.6/25.0 25/25 MCA-Minimum Circuit Amps MOCP-Maximum Overcurrent Protection ELECTRICAL DATA FOR UNITS WITHOUT ELECTRICAL HEAT SINGLE CIRCUIT BRANCH CIRCUIT MODEL NO. T FLA VOLTS/PH/HZ MAXIMUM MIN WIRE SIZE* HP MCA OVERCURRENT AWG PROTECTION FX4DNF019(0,T)00 1/3 2.8 208/230/1/60 3.5 15 14 FX4DNF025(0,T)00 1/3 2.8 208/230/1/60 3.5 15 14 FX4DNF031(0,T)00 1/2 4.1 208/230/1/60 5.1 15 14 FX4DNF037(0,T)00 1/2 4.1 208/230/1/60 5.1 15 14 FX4DNF043(0,T)00 1/2 4.1 208/230/1/60 5.1 15 14 FX4DNF049(0,T)00 3/4 6.0 208/230/1/60 7.5 15 14 FX4DNF061(0,T)00 3/4 6.0 208/230/1/60 7.5 15 14 FX4DNB031T00 1/2 4.1 208/230/1/60 5.1 15 14 FX4DNB037T00 1/2 4.1 208/230/1/60 5.1 15 14 FX4DNB043T00 1/2 4.1 208/230/1/60 1 5.1 15 14 FX4DNB049T00 3/4 6.0 208/230/1/60 7.5 15 14 FX4DNB061T00 3/4 6.0 208/230/1/60 1 7.5 15 14 " Use copper wire only.Use 75°C only in this application.When using non-metallic(NM)sheathed cable,wire size required should be based on that of 60°C conductors,instead of wire sizes shown in table above per NEC Article 336-26. NOTE:If branch circuit wire length exceeds 100 ft(30 m),consult NEC 215-2 to determine maximum wire length.Use 2%voltage drop. FLA-Full Load Amps 13 ACCESSORY ELECTRIC HEATER ELECTRICAL DATA BRANCH CIRCUIT HEATER AMPS P INTERNAL 2081230V Min Ampecity Min Wire Size(AWG) Min Gad win,Size Men Fuse/Ckt Bkr Amps M.Wire Length HEATER kW H CIRCUR 208/230V• 208/230V1 2081270y 208I230V 208/230V(Ft)1 PART NO. A PROTEC- S Dual Cln9alt Dual Circuit Dual Circuit Dual Circuit Dual ClrcuK Dual Circuit E TION Single Single Single Single SIn91e Single 240v 208v circuit L1,12 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,LA Circuit L7,L2 L3,IA KFCEH0401NO3 3 2.3 1 None 10.9/12.0 — — 15.9/17.3 — — 12112 — — 12112 — — 20/20 — — 67/68 — — KFCEH0501N051 5 3.8 1 None 18.1/20.0 — — 26.0/28.4 — — 10/10 — — 10/10 — — 30/30 — — 66166 — — KFCEH0501N052 5 3A 1 None 18.1/20.0 — — 312J335 — — 8/8 — — 10/10 — — 35135 — — W88 — — KFCEH2401C05t 5 3.8 1 Ckt Bkr 1B.1/20.0 — — 26.0/28A — — 10/10 — — 10110 — — 30/30 — — 66166 — — KFCEH2401C052 5 3.8 1 CH Bkr 18.1/20.0 — — 317J335 — — 0/8 — — 10110 — 85188 — — KFCEH0801 N08 8 6.0 1 None 28.9132.0 — — 44.7/4B5 — — SIB — — 10/10 — — 45150 — — 59/60 — — KFCEH2501C08 6 6.0 1 Ckt Bkr 28.9/32A — — 44.7/48.5 — — 8/6 — — 10/10 — — 45/50 — — 59I60 — — KFCEH2901N09 9 6A 1 None 32%36.0 — — 49.5/53.5 — — 818 — — 10/10 — — 50/60 54/87 — — KFCEH2901N09•• 9 6.8 3 None 18.8120.8 — — 32.0134.5 — — 8/B — — 10110 — — 35135 — — 83/85 KFCEH090INIO 1D 7.5 1 None 362J40.0 — — 532/58Z — — 616 — — VV10 — — 60/60 78/80 — — KFCEH2601C10 10 7.5 1 Ckt Bkr P10.9414102jA-- .0 — — 53.8/58.5 — — 616 — — 10/10 60/60 — — 78/80 — — KFCEM3001F75 15 11.3 1 Fuse A 36.2/40.0 18.1120.0 76.3183A 53.8/58.5 22.7/25.0 4/4 6/fi 10110 8/8 10/10 10/10 t10/90 60/60 25/25 88/89 78/80 75/76 KrCEH3101C1S 15 11.3 1 Ckt Bkr36.2/40.0 iS.1120. — 53.8/585 22.7/25.0 — 6/6 10/10 — 10/10 1D/10 — fi0/60 25125 — 78/BO 75/76 KFCFJ11601315 15 119 3 None .8 — — 47.7/51A — — 8/6 — — 10/10 — — 50/60 KFCEH2O01318 iB 13.5 3 None .5 — — 555/60A — — 616 — — 1018 — — 60/70 — — KFCEH3201F20 20 15.0 1 Fuse 9 36.2140.0 36.2140.0 9B.9/108.4 53A/585 45.3/50.0 312 616 818 B/6 10/10 10110 1001110 60/60 50/50 85/109 78/80 59/59 KFCEH330IC20 20 15.0 1 Ckt Bkr36.2140.0 36.2/40.0 — 53.8/5115 45.3/60.0 — 6/8 8/8 — 10I10 10/10 — 6also 50150 — 78/80 59/59 �. 24 10.0 3 Fuse A — — 712J77A — — 414 — — 6/e — — 80180 — — 94195 — — A KFCEH3401F24t1 — — — — — — 24 18.0 1 Fuse 5.5. — — 116.9/127.9 — — Ill — — 6/6 1251150 115/176 30 22.5 3 Fuse 9.2 — — 862/95.0 — — 3/3 — — 8/8 — — 80/100 — — 97/98 — — KFCFJ13501F30t1 — — — — — — — 30 22.5 1 Fuse 20.0 — — 1448/158.5 — — 0/00 — 6/6 1=175 117 150 FIELD MULTIPOINT WIRING OF 24-AND 30-kW SINGLE PHASE P MAX FLISE/CKT BKR MAX WIRE LENGTH HEATER AMPS MIN AMPACITY MIN WIRE SIZE(AWG) MIN GND AMPS HEATER PART kW A 208/230V 208/230V* 208/230Vt WIRE SIZE 208 230V 208/230V(Fn# NO. S 208/230V 240V '208V E L1,L2 L3,L4 LS,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3JA LS,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,LA LS,L6 KFCEH3401 F24tt 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/4+. 4 .2140.0 8/8 8/8 8/8 10110 45/50 40/40 40/40 59/60 73/73 73173 KFCEH3501 F30ft 30 22.5 1 36.2/40.0 36.2/40.0 36.2140.0 53.8/58.5 45.3/5 .3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78180 59/59 59/59 * Includes blower motor amps of largest fan coil used with heater. t Copper wire must be used.If other than uncoated(non—plated),75°C ambient,copper wire(solid wire for 10 AWG and smaller,stranded wire for larger than 10 AWG)is used,consult applicable tables of the National Electric Code(ANSI/NFPA 70). * Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. ** Field convertible to 3 phase. tt Field convertible to 1 phase,single or multiple supply circuit.. NOTES: 1. For fan coil sizes 018-037. 2. For fan coil sizes 042-061. 3. Single circuit application of F15 and F20 heaters requires single—point wiring kit accessory. HEATER ELECTRICAL DATA FACTORY-INSTALLED HEATER OPTIONS* MODEL 019 1 025 1 031 037 043 1 049 1 061 FX4DNF 5 1 5 1 8 10 1 10 1 10 1 10,15 * For field-installed heater/fan coil combinations,see Accessory Electric Heaters. ELECTRIC HEATER INTERNAL PROTECTION FUSE CKT BKR* HEATER kW PHASE QTY/SIZE QTY/SIZE 5 1 — 1/60 8 1 — 1/60 9 1/3 — — 10 1 — 1/60 15 1 2/30-2/60 2/60 15 3 — 18 3 — 20 1 4/60 2/60 24 1/3 6/60 — 30 1/3 6/60 — * All circuit breakers are 2 pole. When using units with 20-,24-,and 30-kW electric heaters,maintain a 1-in. (25 mm)clearance from combustible materials to discharge plenum and ductwork and maintain a distance of 36 in.(914mm)from the unit.Use an accessory downflow base to maintain proper clearance on downflow installations.Use flexible connectors between ductwork and unit to prevent transmission of vibration.When electric heater is installed,use heat resistant material for flexible connector between ductwork and unit at discharge connection.Ductwork passing through unconditioned space must be insulated and covered with vapor barrier ACCESSORIES ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH 1. Disconnect Kit KFADK0201 DSC Cooling controls and heaters 3-through 10-kW KFACB0201 CFB 019,025 2. Downflow Base Kit KFACB0301CFB 031,037,043 KFACB0401CFB 049,061 KFADCO201 SLP Slope Coil Units—019,024,031 3. Downflow Conversion Kit f KFADC0401ACL A-Coil Units—037,043,049,061 4. Downflow/Horizontal Conversion Gasket Kit KFAHDO101 SLP All 5. Horizontal Water Management Kit(25 pack)$ KFAHCO125AAA All 6. Single-Point Wiring Kit KFASP0101SPK Only with 15-and 20-kW Fused Heaters KFAFK0112SML NA KFAFK0212MED 019,025 7. Filter Kit(12 Pack) KFAFK0312LRG 031 037,043 KFAFK0412X0(L 049,061 FNCCABCCO014 NA (FILXXFNC0014) FNCCABCCO017 019,025 8 Fan Coil Filter Cabinet (FILXXFNC0017) (Fan Coil Filter Media) FNCCABCCO021 031,037,043 (FILXXFNC0021) FNCCABCCO024 049,061 (FILXXFNC0024) 9. PVC Condensate Trap Kit(50 pack) KFAET0150ETK All 10. Air Cleaner 240-volt Conversion Kit KEAVCO201240 All * Factory authorized and listed,field-installed. t KFAHDO101 SLP must also be purchased for downflow applications. t KFAHD0101 SLP must also be purchased for downflow or horizontal applications. 15 ACCESSORY KITS DESCRIPTION SUGGESTED AND REQUIRED USE 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE:Units for 3-through 10-kW electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1-in.minimum clearance between unit discharge plenum,ductwork, and combustible materials.It also provides a gap-free seal with the floor. REQUIRED USE:This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications.Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications.Separate kits are available for slope coils and A-coils. REQUIRED USE:This kit must be used whenever fan coils are used in downflow applications. 4. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED USE:Fan coils in either downflow or horizontal applications. 5. Horizontal Applications-Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. SUGGESTED USE: All fan coils. 6. Single Point Wiring Kit The single point wiring kit acts as a jumper between Ll and L3 lugs,and between the L2 and L4 lugs.This allows the installer to run two heavy-gauge,high-voltage wires into the fan coil rather than 4 light-gauge,high-voltage wires. SUGGESTED USE:Fan coils with 15-and 20-kW fused heaters only. 7. Filter Kit(12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil.This process helps to keep the coil clean, which increases heat transfer and,in turn,the efficiency of the system. SUGGESTED USE:To replace filters in fan coils. REQUIRED USE:All units unless a filter grille is used. 8. Fan Coil Filter Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing.The cabinets are insulated using the same insulation as production fan coils.They are designed for the removal of particulates from indoor air using FILXXFNC00(14,17,21,24)media filter cartridges.These fan coil media filter cartridge kits are designed for the removal of particles from indoor air.The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE:All fan coils. 9. Condensate Drain T)rap Kit This kit consists of 50 PVC condensate traps.Each trap is pre-formed and ready for field installation.This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE:All fan coils. 10. Air Cleaner 240-volt Conversion Kit The AIRA electronic air cleaner comes ready for 115-v operation. REQUIRED USE:This kit is required when running 240-volt circuit to air cleaner. Copyright 2010 Carrier Corp.•7310 W.Morris St.• Indianapolis,IN 46231 Printed in U.S.A. Edition Date: 09/10 Catalog No: FX4D—lli PD Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. Replaces: NEW 16 24A13133 Comfort Conditioner with Puron@ Refrigerant Carrier expert1 —1/2 to 5 Nominal Tons turn to the Product Data INDUSTRY LEADING FEATURES BENEFITS �dzk ,s y. a Efficiency 13 SEER/up to 11 EER (based on tested combinations) �„NI� �Ir•: ... �^ • Microtube Technology- refrigeration system � ItlNll • Indoor air quality accessories available �j��p�111 ��,��1"��1IIII�NIIiIIIINIAf Sound � � • Sound level as low as 71 dBA �i11111 �I�� Comfort System supports Edge® Thermidistat- or standard thermostat controls Reliability • Non-ozone depleting PUIon®refrigerant • Scroll compressor • Internal pressure relief valve Internal thermal overload Comfort • Filter drier Nron.. S E R I E S • Balanced refrigeration system for maximum reliability Durability Carrier's Air Conditioners with Puron® refrigerant provide a WeatherArmor- protection package: collection of features unmatched by any other family of • Solid,durable sheet metal construction equipment. The 24ABB has been designed utilizing Carrier's non-ozone depleting Puron refrigerant. • Dense wire coil guard • Baked-on,complete outer coverage, powder paint NOTE: Ratings contained in this document are subject to Applications change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings • Long-line- up to 250 feet(76.20 m) total equivalent information. length, up to 200 feet (60.96 m) condenser above evaporator,or up to 80 ft.(24.38 m)evaporator above condenser(See Longline Guide for more information.) • Low ambient (down to -20°F/-28.9°C)) with accessory kit W Irv `': s j+ N O V 1 2 2024 .,., MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 N N A A A/N N N N A/N A/N A/N N N 2 4 A B B 3 3 6 A 0 N 3 0 Product Product Major Cooling Design Series Family Tier Series SEER Capacity Grille Variations Variation Region Voltage Series 3=208/230-1 0= 24=AC A=RES AC B=Comfort B=Puron 3=13 SEER 1.000 Btuh A=Dense Grille N=North 5= =460 3 Original 1 (nominal) 575/3 Series =57 Nron. _ c Y L us Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification , of certification for individual products,go to ISO 9001 www.ahridirectory.org. QMl-SAI Global STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X SEER 13 13 13 13 13 13 13 Scroll Compressor X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Dense Grille X X X X X X X X=Standard 2 PHYSICAL DATA , UNIT SIZE SERIES 18-34 24-35 30-33 30-51 36-35 36-51,61,11 50,60 42-30, 48-51, 60-52 48-36 61,11 60-34 62,12 Compressor type Scroll REFRIGERANT Puron®(R-410A) Control TXV(Puron®Hard Shutoff) Charge lb(kg) 3.15 3.15 4.62 4.10 5.42 5.34 5.84 7.37 7.00 8.80 8.00 (1.4) (1.43) (2.10) (1.9) (2.46) (2.4) (2.65) (3.34) (3.2) (4.0) (3.6) COND FAN Propeller Type,Direct Drive Air Discharge Vertical Air Oty(CFM) 1792 2218 2163 1 2218 3167 2954 3167 3365 3365 3365 3365 Motor HP 1/12 1/10 1/10 1 1/10 1/5 1/4 1/5 1/4 1/4 1/4 1/4 Motor RPM 1100 1100 1100 1100 1100 1100 1100 1100 1100 800 1100 COND COIL Face Area(Sq ft) 8.40 8.40 11.49 9.80 12.93 13.13 17.25 19.40 19.40 12.93 15.09 Fins per In. 20 25 25 25 25 25 25 25 25 20 20 Rows 1 1 1 1 1 1 1 1 1 2 2 Circuits 3 3 3 3 5 3 4 5 5 5 6 VALVE CONNECT.(In.ID) Vapor 1 3/4 3/4 3/4 3/4 7/8 7/8 7/8 718 7/8 7/8 1 7/8 Liquid 1 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 REFRIGERANT TUBES*(In.OD) Rated Vapor* 3/4 7/8 1-1/8 Max Liquid Linet 3/8 *Units are rated with 25 ft(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. t See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. OUTDOOR UNIT CONNECTED TO A FACTORY APPROVED INDOOR UNIT Check piston size shipped with indoor unit to see if it matches required indoor piston size. If it does not match,replace indoor piston with correct piston size in table below: OUTDOOR UNIT SIZE—SERIES FAN COIL PISTON SIZE BY OUTDOOR MODEL 18-34 FB4CNF* 49 24-35 FB4CNF* 55 30-33 FB4CNF* 61 30-51 FB4CNF* 59 36-35 FB4CNF* — 36-51,61,11 FB4CNF* 67 42-30,50,60 FB4CNF* 73 48-36 FB4CNF* 78 48-51,61,11 1FB4CNF* 76 * Ratings contained in this document are subject to change at any time.Always refer to the AHRI directory(www.ahridirectory.org)for the most up—to—date ratings information. NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. The piston included with the FFMANP*and FPMAN* fan coils are unique to those products and CANNOT be replaced with the piston shipped with outdoor unit. Refer to the AHRI directory (wwwahridirectory.org)to check if your combination can use a piston or requires an accessory TXV. 3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line SiZing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron®Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Liquid AC with Puron Refrigerant Liquid Line Line Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Size Connection Diam. Vertical Separation ft(m) w/TXV 0-5 6-10 11-20 21-30 31-40 41-50 51-60 61-70 71-80 (0-1.5) (1.8-3.0) (3.4-6.1) (6.4-9.1) (9.4-12.2) (12.5-15.2) (15.5-18.3) (18.6-21.3) (21.6-24.4) 1/4 150 150 125 100 100 75 -- -- -- 18 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 225* 150 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 75 75 75 50 50 -- -- -- -- 24 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* - -1/4 --30-- -- 30 3/8, 5/16 175 225* 200 175- 125 100, 75 -- _ .•------- _. 3/8 --- - 250* -250*-- 250*- ---:250*---- - 250* -250*--• - -,-250*-,--- '.250* __. 250* 36 3/8 5/16 175 150 150 100 100 100 75 -- -- 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 42 3/8'.' 5116 125 100 100 75 75 50 -- -- 3/8 250* 250* 250* 250* 250* 250* 250* 250* 150 48 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 -- 60 3/8 3/8 250* 250* 250* 225* 190 150 110 -- -- * Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. --=outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Liquid AC with Puron Refrigerant Liquid Line Line Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Size Connection Diam. Vertical Separation ft(m) W/TXV 25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 (7.6) (7.9-15.2) (15.5-22.9) 23.2-30.5) (30.8-38.1) (38.4-45.7) 46.0-53.3) (53.6-61.0) 1/4 175 250* 250* 250* 250* 250* 250* 250* 18 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 100 125 175 200 225* 250* 250* 250* 24 318 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* ---- - -1/4— 30. -- '30 3/8 5/16 250*• 250* 250*- 250.*. 250* 250* 250* 250* ._- -3/8' - 250*- 250* -250*,-- ---250* -250— ._. 250— -250*- - -'-250*. 36 3/8 5/16 225* 250* 250* 250*- 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 42 318 5/16 175 200 250* 250* 250* 250* 250* 250* 3/8, 250* 250* 250* 250* 250* 250*. 250* 250* 48 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 60 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* *Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. --=outside acceptable range 4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft(g/m) 3/8 0.60(17.74) (Factory charge for lineset=9 oz/266.16 g) 5/16 0.40(11.83) 1/4 0.27(7.98) Units are factory charged for 15 ft(4.6 m)of 3/8"liquid line. The factory charge for 3/8"lineset 9 oz. When using other length or diameter liquid lines,charge adjustments are required per the chart above. Chareint=_Formula: [(Lineset oz/ft x total length)-(factory charge for lineset)]=charge adjustment Example 1:System has 15 ft of line set using existing 1/4"liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft)-(9 oz)=(4.95)oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16"liquid line.What is the charge adjustment? Formula: (.40 oz/ft.x 45ft)-(9 oz.)=9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method.Indoor temperature must be 70°F to 80°F(21.1°C to 26.7°C), and outdoor temperature must be 70°F to 100°F(21.1°C to 37.8°C).If outside these conditions,adjust charge for long line sets by weigh-in method. LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter,actual length of the tubing,and vertical separation between the indoor and outdoor units. For Air Conditioner systems,the chart below shows when an application is considered Long Line. AC with Puron®Refrigerant Long Line Description ft(m)Beyond these lengths,a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft.(15.2 m) TXV required beyond 20 ft.(6.1 m) AC with Porous Refrigerant Long Line Description ft(m)(Beyond these lengths,long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4+TXV No accessories needed within al- No accessories needed within 175(53.3) lowed lengths allowed lengths 5/16+TXV 120(36.6) 50(15.2)vertical or 120(36.6)total 120(36.6) 3/8 +TXV 80(24.4) 35(10.7)vertical or 80(24.4)total 80(24.4) Note: See Residential Piping and Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses—Puron®Refrigerant 1-Stage Air Conditioner Applications Maximum Cooling Capacity Loss(%) Unit Vapor Line Total Equivalent Line Length ft.(m) Nominal Liquid Line Diameters 1-Stage AC with Puron Size Bh tu Diameters in.OD ( ) (In.OD) ( ) 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (7.9-15.2) (15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2) 1/2 1 2 3 5 6 _7 8 9 11 18 3/8 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 5/8 0 1 2 2 3 3 4 5 5 24 3/8 3/4 0 0 1 1 1 1 1 2 2 7/8 0 1 0 0 0 0 1 1 1 1 - - -5/8- 1 30 3/8 3/4 0 0 1 :_r s.1._r 1 ,�: h •2,r t i>1��:21�' i 2' J .:3 - - 7/8- 0 _ 0- v 0 5/8 1 2 4 5 6 8 9 10 12 36 3/8 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1. 1 1 1 2 2 3/4 0 1 ;t2 .`2 '' t3 �q 6= 42 3/8 7/8 00 1'_ 1 ; 1 2 `2`" '2" 3 1 1/8 0 0 0:. ' 0 1.0'`-,: 0' 0. 0; 0 314 0 1 2 3 4. 5 5 frj 6 7 48 3/8 7/8 0 0 1 1 2 2 2 3 3 11/8 0 0 0 0 0 0 0 1 1 3/4 1 2 4 5 6 7 9 10 11 60 3/8 7/8 0 1 2 2 3 4 4 5 5 11/8 0 0 0 1 1 1 1 1 1 �ApplicdGons'm this areamay be long line and may have height restrictions. See tffe ResidentiarPipin—and-Lon Une Guideline. 5 ACCESSORIES KIT NUMBER KIT NAME Size—Voltage,Series 18-34 24-35 30-33 30-51 36-35 36-51 36-61 36-11 42-30 42-50 42-60 48-36 48-51 48-61 48-11 60-34 60-52 60-62 60-12 HC38GE461 MOTOR,FAN X HC40GE466 MOTOR,FAN X X KAACH1201AAA CRANKCASE HEATER KIT X X X X X X KAACH1401AAA CRANKCASE HEATER KIT X X X X X X KAACH1601AAA CRANKCASE HEATER KIT X KAACH1801AAA CRANKCASE HEATER KIT X KAACH1901AAA CRANKCASE HEATER KIT X X X KAACH2O01AAA CRANKCASE HEATER KIT X X KAAFT0101AAA FREEZE THERMISTOR KIT X X X X X X X X X X X X X X X X X X X KAATD0101TDR TIME DELAY KIT X X X X X X X X X X X X X X X X X X X KSACY0101AAA CYCLE PROTECTOR KIT X X X X X X X X X X X X X X X X X X X WWS0101MA WINTER START KIT X X X X X X X X X X X X X X X X X X X KSALA0301410 LOW AMBIENT KIT X X X X X X X X X X X X X X X X X X X KSALA0601AAA MOTORMASTER KIT X X X X X X X X X X X X KSALA0701AAA MOTORMASTER KIT X X X X KAALP0401PUR LOW PRESSURE SWITCH KIT X X X X X X X X X X X X X X X X X X X KAALP0501PUR HIGH PRESSURE SWITCH KIT X X X X X X X X X X X X X X X X X X X KSASF0101AAA SUPPORT FEET KIT X X X X X X X X X X X X KSASF0201AAA SUPPORT FEET KIT X X X X X X X KSASH2301COP SOUND BLANKET KIT X X X X X X X X X X X X KSASH2401COP SOUND BLANKET KIT X X X X KSASH2501COP SOUND BLANKET KIT X X X Os KAALS0201 LLS SOLENOID VALVE KIT X X X X X X X X X X X X X X X X X X X KSAHS1501AAA COMPRESSOR START ASSIST X X X X X X X KSATX0201PUR TXV KIT X X KSATX0301 PUR TXV KIT X X X X X X X X X KSATX0401 PUR TXV KIT X X X X KSATX0501 PUR TXV KIT X X X X KSBTX0201 PUR TXV KIT X X KSBTX0301 PUR TXV KIT X X X X X X X X X KSBTX0401PUR TXV KIT X X X X X X X X X=Accessory AHRI RATINGS For AHRI ratings certificates,please refer to the AHRI directory www.ahridirectoo.org Additional ratings and system combinations can be accessed via the Carrier database at:www.MyCarrierRatings.com For performance data at specific application&/or design conditions with various indoor unit combinations,the equipment performance calculator can be accessed at: http://rpmob.wricihtsoft.com/ ACCESSORY THERMOSTATS PART NUMBER DESCRIPTION TP-WEM01 Cdr' Thermostat TP-PRH01-A edge-Programmable Relative Humidity Thermostat TP-PAC01 edge-Programmable Thermostat TP-NRH01 edge-Non-Programmable Relative Humidity Thermostat TP-NAC01 edge-Non-Programmable Thermostat TC-WHS01 Wi-Fi®Thermostat TC-PAC01 Programmable Thermostat TC-NAC01 Non-Programmable Thermostat TCSNAC01 Non-Programmable Standard Screen Thermostat THERMOSTAT ACCESSORIES PART NUMBER DESCRIPTION THERMOSTATS USED WITH TP-EXP edge"EXP®Card Programmable edge"thermostats TSTATCCSEN01-B Outdoor Air Temperature Sensor TP-Pxx,TP-Nxx TSTATXXCNV10 Thermostat Conversion Kit(4 to 5 wire)-10 pack All Carriers branded thermostats TX-MBP01 Medium Decorative Backplate TC-Nxx TX-LBP01 Large Decorative Backplate TP-Pxx,TP-Nxx,TC-Pxx ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR ACCESSORY LOW-AMBIENT COOLING REQUIRED FOR LONG LINE SEA COAST APPLICATIONS APPLICATIONS* APPLICATIONS (Below 55°F/12.8'C) (Within 2 miles/3.22 km) Ball Bearing Fan Motor Yest No No Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Hard Shut-Off TXV Yes Yes Yes Liquid Line Solenoid Valve No No No Motor Master Control or Yes No No Low-ambient Pressure Switch Support Feet Recommended No Recommended Winter Start Control Yes# No No For tubing set lengths between 80 and 200 ft.(24.38 and 60.96 m)horizontal or 35 ft.(10.7 m)vertical differential(total equivalent length),refer to the Residential Split-System Longline Application Guideline. t Required for Low-Ambient Controller(full modulation feature)MotorMaster®Control.Standard on all models except 575V 3-phase units. # Required if Low Pressure Switch is factory or field installed. Accessory Description and Usage (Listed Alphabetically) 1.Ball-Bearing Fan Motor 3.Crankcase Heater A fan motor with ball bearings which permits speed reduction An electric resistance heater which mounts to the base of the while maintaining bearing lubrication. compressor to keep the lubricant warm during off cycles. Usage Guideline: Improves compressor lubrication on restart and minimizes the Required on all units when MotorMaster° is used. chance of liquid slugging. 2.Compressor Start Assist-Capacitor and Relay Usage Guideline: Start capacitor and relay gives a "hard" boost to compressor Required in low ambient cooling applications. motor at each start up. Required in long line applications. Usage Guideline: Suggested in all commercial applications. Required for reciprocating compressors in the 4. Cycle Protector following applications: The cycle protector is designed to prevent compressor short Long line cycling. This control provides an approximate 5-minute delay Low ambient cooling after power to the compressor has been interrupted for any Hard shut off expansion valve on indoor coil reason,including power outage,protector control trip,thermostat Liquid line solenoid on indoor coil jiggling,or normal cycling. Required for single-phase scroll compressors in the 5.Evaporator Freeze Thermostat following applications: An SPST temperature-actuated switch that stops unit operation Long line when evaporator reaches freeze-up conditions. Low ambient cooling Usage Guideline: Suggested for all compressors in areas with a history of Required when low ambient kit has been added. low voltage problems. 7 Accessory Description and Usage (Listed Alphabetically) (Continued) 6.Low-Ambient Pressure Switch Kit 10.Support Feet A long life pressure switch which is mounted to outdoor unit Four or five stick-on plastic feet that raise the unit 4 in. (101.6 service valve. It is designed to cycle the outdoor fan motor in mm) above the mounting pad. This allows sand, dirt, and other order to maintain head pressure within normal operating limits debris to be flushed from the unit base,minimizing corrosion. (approximately 100 psig to 225 psig).The control will maintain Usage Guideline: working head pressure at low-ambient temperatures down to 0°F Suggested in the following applications: (-18°C)when properly installed. Coastal installations. Usage Guideline: A Low-Ambient Pressure Switch or MotorMaster® Windy areas or where debris is normally circulating. Low-Ambient Controller must be used when cooling operation is Rooftop installations. used at outdoor temperatures below 55°F(12.8°C). For improved sound ratings. 7.MotorMaster®Low-Ambient Controller 11.Thermostatic Expansion Valve(TXV) A fan-speed control device activated by a temperature sensor, A modulating flow-control valve which meters refrigerant liquid designed to control condenser fan motor speed in response to the flow rate into the evaporator in response to the superheat of the saturated, condensing temperature during operation in cooling refrigerant gas leaving the evaporator. mode only.For outdoor temperatures down to-20°F(-28.9°C), Kit includes valve, adapter tubes, and external equalizer tube. it maintains condensing temperature at 1007±10°F(37.8°C x Hard shut off types are available. 5.5°C). NOTE: When using a hard shut off TXV with single phase Usage Guideline: reciprocating compressors, a Compressor Start Assist Capacitor A MotorMaster@ Low Ambient Controller or and Relay is required. Low-Ambient Pressure Switch must be used when Usage Guideline: cooling operation is used at outdoor temperatures Required to achieve AHRI ratings in certain equipment below 55°F(12.8°C). combinations.Refer to combination ratings. Suggested for all commercial applications. Hard shut off TXV or LLS required in air conditioner 8.Outdoor Air Temperature Sensor long line applications. Designed for use with Carrier Thermostats listed in this Required for use on all zoning systems. publication. This device enables the thermostat to display the 12.Time-Delay Relay outdoor temperature.This device also An SPST delay relay which briefly continues operation of indoor is required to enable special thermostat features such as auxiliary blower motor to provide additional cooling after the compressor heat lock out. cycles off. Usage Guideline: NOTE:Most indoor unit controls include this feature.For those Suggested for all Carrier thermostats listed in this that do not,use the guideline below. publication. Usage Guideline: 9.Sound Hood For improved efficiency ratings for certain Wraparound sound reducing cover for the compressor. Reduces combinations of indoor and outdoor units.Refer to the sound level of the compressor. AHRI Unitary Directory. Usage Guideline: 13. Winter Start Control Suggested when unit is installed closer than 15 ft(4.57 m)to This control is designed to alleviate nuisance opening of the quiet areas,bedrooms,etc. low-pressure switch by bypassing it for the first 3 minutes of Suggested when unit is installed between two houses less operation. than 10 ft(3.05 m)apart. 8 ELECTRICAL DATA UNIT SIZE- OPER VOLTS* COMPR FAN MAX FUSE**or VOLTAGE, V/PH MCA CKT BRK AMPS SERIES MAX MIN LRA RLA FLA 18-34 47.5 9.0 0.50 11.8 20 24-35 62.9 10.9 0.70 14.3 25 30-33 67.8 12.8 0.60 16.6 25 36-35 208/230/1 253 197 79.0 13.6 1.10 18.1 30 M2- 48-51 112.0 17.9 1.10 23.5 40 93.0 18.3 1.40 24.3 40 125.0 22.1 1.40 29.0 50 58.0 8.3 0.77 11.2 20 71.0 10.5 1.40 14.5 20 21 208/230-3 253 187 88.0 13.5 1.10 18.0 30 83.1 13.1 1.40 17.8 30 110.0 16.0 1.40 21.4 30 36-61 38.0 5.6 0.70 7.7 15 42-60 44.0 6.0 0.60 8.1 15 48-61 460-3 506 414 41.0 6.1 0.70 8.3 15 60-62 52.0 7.8 0.70 10.5 15 36-11 36.5 3.8 0.50 5.3 15 48-11 575-3 532 518 33.0 4.4 0.50 6.0 15 60-12 38.9 5.7 0.50 7.6 15 *Permissible limits of the voltage range at which the unit will operate satisfactorily. **Time-Delay fuse. FLA -Full Load Amps LRA -Locked Rotor Amps MCA-Minimum Circuit Amps RLA -Rated Load Amps NOTE:Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 A-WEIGHTED SOUND POWER LEVEL STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA,without tone adjustment) 24ABB3 UNIT SIZE RATING dBA 125 250 500 1000 2000 4000 8000 18-34 71 64.0 62.0 63.0 68.0 64.0 62.0 57.0 24-35 74 50.9 60.6 66.4 71.0 65.5 61.1 59.2 30-33 72 54.8 59.3 65.1 68.2 66.4 61.6 57.3 30-51 74 55.0 63.5 68.5 68.5 65.5 61.0 54.0 36-35 75 50.5 61.0 64.5 67.0 62.5 60.0 52.5 36-51,61,11 75 59.5 63.0 68.5 70.0 65.5 61.5 53.5 42-30,50,60 78 57.5 65.0 71.0 73.0 70.5 67.5 62.5 48-36 76 55.5 62.9 69.6 71.2 69.5 66.3 59.1 48-51,61,11 80 58.5 67.5 73.5 75.0 70.5 67.5 64.5 60-34 79 57.5 67.0 72.0 75.0 72.5 68.0 61.0 60-52,62,12 79 59.5 69.5 72.5 73.5 71.0 68.0 63.5 NOTE: Tested in accordance with AHRI Standard 270-2008(not listed in AHRI). A-WEIGHTED SOUND POWER LEVEL WITH SOUND SHIELD STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA,without tone adjustment) UNIT SIZE RATING dBA 125 250 500 1000 2000 4000 8000 18-34 70 66.0 64.0 64.0 67.0 63.0 60.0 54.0 24-35 74 51.1 61.3 66.6 71.2 65.0 60.0 55.6 30-33 72 51.9 59.3 64.8 67.3 65.2 61.1 54.8 30-51 73 55.5 64.0 68.0 67.0 64.0 60.0 52.5 36-35 75 51.0 62.0 64.5 65.5 62.0 59.5 51.5 36-51,61,11 74 59.5 63.0 68.0 1 69.5 65.0 60.5 50.5 42-30,50,60 77 57.5 65.0 70.5 72.0 70.0 67.0 62.0 48-36 75 55.8 62.6 69.7 70.6 68.7 65.4 58.6 48-51,61,11 79 60.5 67.5 73.5 74.5 71.0 68.0 63.5 60-34 79 57.5 68.0 72.5 74.5 72.5 68.0 60.5 60-52,62,12 78 60.5 69.5 72.5 73.0 71.0 67.5 61.5 NOTE: Tested in accordance with AHRI Standard 270-200B(not listed in AHRI). CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-VOLTAGE&SERIES REQUIRED SUBCOOLING°F(°C) 18-34 14(7.8) 24-35 10(5.6) 30-33,51 10(5.6) 36-35 11 (6.1) 36-51,61,11 14(7.8) 42-30,50,60 10(5.6) 48-36 13(7.2) 48-51,61,11 15(8.3) 60-34 15(8.3) 60-52,62,12 10(5.6) 9 DIMENSIONS - ENGLISH SHOPPING OR WEIGHT SHIPPING SMPPHT UNIT SERIES ELECTRICAL A B C 0 E F G X 1 J K WEIGNi WEIGHT LENGTH I HEIGHT CHARACTERISTICS (69d INCH I AM INCH MM INCH MM INCH MM INCH MM INCH MM INCH KIM INCH m INCH ADA INCH KIM INCH MM Lbs K9s Lbs K9s INCH MM INCH MM 24ABB31BA 4 Y N N N 23 1/8 587.3 25 918 642.9 31419.1 4 7116 113.0 18 1/16 459D 7IT16 197.9 5/16 7.9 3 762 16 112 419.1 15 381.0 12 304.8 107 484 In 69.0 25 114 641.5 29 S(4 765.8 24ABB324A 5 Y N N N 23 118 587.3 25 5116 642.9 314 19.1 4 7/16 113.0 18 1116 459.0 713116 197.9 5116 7.9 3 762 12 1/2 317.5 11 279.4 12 304.8 107 48.5 127 57.6 25 1/4 641.5 29 34 755.8 24ABB330A 3 Y N N N 25 314 654.0 2811116 728.7 314 19.1 4 7116 113.0 21 114 539.9 9 118 231.3 5116 7.9 3 762 14 1/2 368.3 15 112 393.7 12 1/2 317.5 126 572 149 67.6 27 7/8 7082 33 3116 843.1 24ABB33QA 1 N Y N N 23 1/8 587.3 251111E 729.3 314 19.1 4 7116 113.0 18 1116 459.0 713H6 197.9 5116 7.9 3 762 16 1/2 419.1 15 381.0 14 355.6 111 50.3 136 61.7 1 25 114 641.5 33 3H8 843.1 24ABB336A 5 Y N N N 31 3116 792.5 25 916 642A 718 222 6 9116 166.1 2411116 6263 9 118 231.3 5116 7.9 3 762 15 9/16 3953 16 12 419.1 10 114 260A 134 60.8 151 68.5 33 5116 846.6 29 34 755.8 24ABB336A 1 N Y V V 1 25 314 654.0 32 V78 815.1 718 222 1 4 7116 113.0 21 114 34 539.9 9 7/8 231.3 5116 7.9 3 762 14 1/4 362A 10 12 266.7 16 406.4 141 64.0 170 77.1 27 718 7082 38 98 929.5 24ABB2A 0 Y Y Y N 31 3116 792.5 32 1116 816.1 718 222 6 9116 166.1 24 11/16 62639 118 2313 915 7.9 3 762 15 314 400.1 16 114 412.8 13 3'4 3493 190 862 215 98.9 33 916 846.6 36 5'B 929.5 24ABB348A 6 Y N N N 31 W16 782S 35 12 901A 718 222 6 9/16 165.1 2411116 62639 118 231.35116 7.9 3 762 15 34 400.1 16 3/8 4159 15 SIG39fi.9 175 79A 205 930 33 1116 846.E 40 10158 2 2 9 4ABB348A 1 N Y Y Y 31 3116 792.5 35 101A 718 2226 9/16 166.1 2411116 62639 1/8 231.3 916 7.9 3 762 16 3/8 415.9 15 MY 3905 15 114 387.4 186 B4A 224 101.6 33 5116 846.6 40 1015.8 24ABB360A 4 Y N N N 31 3116 792.5 2811116 728.7 718 222 6 SM6 166.1 24 11116 6263 9 118 231.3 916 7.9 3 762 1fi 406A 15 12 393.7 12 314 323.9 199 90.3 23Y 1052 33 5/16 846.6 33 3/7fi 843.1 24ABB35GA 2 N Y Y 5$Y� 31 3116 792.5 2811116 728.7 718 2226 916 166.1 2411116 6263 9 118 231.3 916 7.9 3 762 16 406.4 15 12393.7 12 314 323.9 198• 89.8 230 1043 33 916 846.6 33 3116 843.1 Y=YES WNO A 5o. AIR DISCHARGE `\\ F AIR IN AIR DISCHARGE CD O FIELD POWER SUPPLY CONN. B �T18'l022.27 NOLE WITH AIR IN AIR IN 1 1/8.1028.61 KNOCKOUT FIELD CONTROL SUPPLY CONN. 0718•(022.2)HOLE E LIQUID 3LINE000NN, K J 3 3/4' 3 I/2' D (96.01 188.9) H OCVAPOR LINE CONIN.I YSo.� I 1 13n 6' f X50. +{I IJ6.71 I 112.7J 0 +I 3!8'(09.5)TIEDOWN KNOCKOUTS _nXa_ _� 2 13l76' L 121 PLACES UNR SIZE �mnoal�laioxs IT 07 AI]IN 18,24,30 30 23 1/8 1 587.3� 17 718 454.6 30(10),36(30) 25 314 654.0 20 711 S518.5 36 10 42 48 60 31 3116 792.5 22 15/16 583.2 NOTE:ALL DIMENSIONS IN INCH(MM) U.S.EXPORT CLASSIFICATION:EAR99 35 889.0 26 314 679.7 SD5416<REV.C CLEARANCES Clearances (various examples) Wall Wall 6" 24" (152.4 mm) Service 24" 12" 12" 6" (609.6) (304.8) (304.8) 4((12.4) w Service 12" 12„ (304.8) (304.8) Wall 24" 24" 24„ (609.6) (609.6) (609.6) Service Service Service 18" (457.2) (457.2) (457.2) Note: Numbers in () = mm IMPORTANT. When installing multiple units in an alcove,roof well,or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. DETAILED COOLING CAPACITIES# EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuIt Total Sys- 'F(°C) Total Sens# tem KW*• Total Sens# tam KW' Total Sens# tam KW" Total Sens# tam KW*• Total Sens# tern KW Outdoor 72(22.2) 21.21 11.38 1.27 20.31 11.05 1.42 19.41 10.71 1.59 18.37 10.33 1.7a 17.33 9.96 2.02 67(19.4) 19.33 14.06 1.28 18.52 13.73 1.43 17.62 13.36 1.60 16.64 12.96 1.79 15.65 12.56 2.02 525 63(17.2)tt 18.04 16.20 1.29 17.23 15.83 1.44 16.39 15.44 1.60 15.49 15.02 1.79 14.60 14.56 2.02 62(16.7) 17.76 16.72 1.29 16.97 16.34 1.44 16.16 15.93 1.60 15.36 15.36 1.79 14.58 14.58 2.02 57(13.9) 17.47 17.47 1.30 16.77 16.77 1.44 16.08 16.OB 1.60 15.34 15.34 1.79 14.56 14.56 2.02 72(22.2) 21.47 11.95 1.30 20.62 11.65 1.45 19.68 11.30 1.62 18.64 10.93 1.81 17.55 10.55 2.05 67(19.4) 19.71 15.05 1.31 18.81 14.68 1.46 17.90 14.32 1.63 16.89 13.92 1.82 -15.88 13.52 2.05 600 63(17.2)tt 18.40 17.43 1.32 17.61 17.05 1.46 16.77 16.64 1.63 15.96 15.96 1.82 15.14 15.14 2.05 62(16.7) 18.19 18.01 1.32 17.54 17.28 1.46 16.74 16.74 1.63 15.96 15.96 1.82 15.14 15.14 2.05 57(13.9) 18.12 18.12 1.32 17.44 17.44 1.47 16.72 16.72 1.63 15.93 15.93 1.82 15.12 15.12 2.05 72(22.2) 21.70 12.53 1.33 20.81 12.21 1.48 19.86 11.87 1.65 18.78 11.49 1.04 17.62 11.09 2.06 67(19.4) 19.88 15.95 1.34 19.03 15.61 1.49 18.11 15.24 1.66 17.08 14.83 1.85 16.07 14.43 2.08 675 63(17.2)tt 18.79 1B.56 1.35 10.02 18.02 1.49 17.27 17.27 1.66 16.44 16.44 1.85 15.60 15.60 2.08 62(16.7) 18.71 18.71 1.34 18.02 18.02 1.49 17.26 17.26 1.66 16.44 16.44 1.85 15.59 15.59 2.08 57(13.9) 18.70 18.70 1.34 18.00 18.00 1.49 17.24 17.24 1 1.66 16.41 16.41 1.85 15.57 15.57 2.08 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F(°C) 75(23.9) 85(29A) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys. °F(°C) Total Sens# tem KW" Total Sans# tam KW Total Sens# tam KW" Total Sens$ tam KW" Total Sens# tem KW"" Outdoor 72(22.2) 27.00 13.49 1.54 26.00 13.12 1.78 24.88 12.71 2.05 23.60 12.25 2.37 22.20 11.77 2.74 67(19.4) 24.70 16.72 1.54 23.76 16.33 1.78 22.68 15.90 2.05 21.51 15.44 2.37 20.23 14.95 2.74 700 63(17.2)tt 23.00 16.10 1.55 22.07 15.69 1.78 21.07 15.26 2.06 19.97 14.80 2.37 18.77 14.30 2.75 N 62(16.7) 22.70 19.89 1.55 21.81 19.46 1.78 20.88 18.99 2.06 19.95 19.95 2.37 18.98 18.98 2.75 57(13.9) 22.29 22.29 1.55 21.58 21.58 1.78 20.79 20.79 2.06 19.92 19.92 2.37 18.96 18.96 2.75 72(22.2) 27.39 14.17 1.57 26.35 13.79 1.81 25.20 13.38 2.09 23.87 12.92 2.41 22.42 12.43 2.78 67(19A) 25.08 17.82 1.58 M2.4 17.43 1.82 23.00 17.00 2.09 21.79 16.53 2.41 20.47 16.03 2.78 800 63(17.2)tt 23.39 17.14 1.58 16.72 1.62 21.39 16.28 2.09 20.26 15.81 2.41 19.02 15.30 2.79 62(16.7) 23.24 21.32 1.58 22.43 1.82 21.59 21.59 2.09 20.66 20.66 2.41 19.62 19.62 2.79 57(13.9) 23.16 23.16 1.58 22.40 1.82 21.56 21.56 2.09 20.63 20.63 2.41 19.60 19.60 2.79 72(22.2) 27.66 14.81 1.61 14.43 1.85 25.41 14.02 2.13 24.05 13.56 2.45 22.57 13.06 2.82 67(19.4) 25.36 18.88 1.61 18.49 1.85 23.24 18.05 2.13 22.00 17.57 2.45 20.65 17.05 2.8900 63(17.2)tt 23.67 18.11 1.62 17.70 1 1.85 1 21.63 17.25 2.13 20.47 16.77 2.45 19.21 16.24 2.83 62(16.7) 23.89 23.89 1.62 23.10 23.10 1.85 22.21 22.21 2.13 21.22 21.22 2.45 20.13 20.13 2.83 57(13.9) 23.86 23.86 1.62 23.07 23.07 1.85 22.1E 22.18 2.13 21.20 21.20 1 2A5 20.11 20.11 2.83 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C) 75(23.9) B5(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- °F(°C) Total Sens# tem KW Total Sens# tam KW'• Total Sens# tam KW' Total Set s# tam KW" Total Sens# tam KW'• 24ABB330ABN33 Outdoor 72(22.2) 33.22 16.91 2.06 31.69 16.39 2.26 30.06 15.84 2.50 28.48 15.31 2.77 27.41 14.95 3.12 67(19.4) 30.2E 21.08 2.05 28.91 20.56 2.25 27.54 20.04 2.49 26.13 19.52 2.76 24.98 19.08 3.10 875 63(17.2)tt 28.16 20.25 2.04 27.05 19.80 2.25 25.78 19.28 2.49 24.46 18.76 2.76 22.86 18.13 3.08 62(16.7) 28.07 25.27 2.05 26.00 26.56- 2.25 25.71 25.71 2.48 24.60 24.60 2.76 23.29 23.29 3.08 57(13.9) 27.67 27.67 2.04 26.71 26.71 2.25 25.67 25.67 2.48 24.55 24.55 2.76 23.26 23.26 3.08 72(22.2) 33.81 17.69 2.10 32.00 17.08 2.30 30.30 16.51 2.53 28.71 15.99 2.81 27.49 15.59 3.14 67(19.4) 30.64 22.21 2.09 29.20 21.67 2.29 27.80 21.15 2.53 26.35 20.61 2.80 25.09 20.14 3.13 970 63(17.2)11 28.55 1 21.32 2.08 27.34 20.83 2.29 26.03 20.31 2.52 24.67 19.76 2.79 23.13 19.14 3.11 62(16.7) 28.67 28.67 2.09 27.47 27.47 2.29 26.36 26.36 2.52 25.20 25.20 2.80 24.14 24.14 3.14 57(13.9) 28.57 28.57 2.09 27.43 27.43 2.29 26.33 26.33 2.52 25.14 25.14 2.79 24.21 24.21 3.13 72(22.2) 34.10 18.74 2.16 32.36 18.17 2.36 30.60 17.59 2.60 28.93 17.05 2.87 27.70 16.66 3.20 67(19.4) 31.10 23.99 2.15 29.57 23.42 2.36 28.11 22.88 2.59 26.63 22.32 2.86 25.46 21.89 3.21 1125 63(17.2)1.1 29.25 23.06 2.15 27.68 22.44 2.35 26.34 21.90 2.59 24.91 21.33 2.86 23.65 20.80 3.19 62(16.7) 29.57 29.57 2.15 28.41 28.41 2.35 27.20 27.20 2.59 25.99 25.99 2.86 25.03 25.03 3.20 57(13.9) 29.57 29.57 2.15 28.38 28.38 2.35 27.20 27.20 2.59 25.95 25.95 2.86 24.99 24.99 3.20 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys- Capacity MBtuh Total SL. LaSenr4 Cap MBtuh Total Sys- Capacity Metuh Total Sys- Capacity MBtuh Total Sys- -F(°C) Total Sens# tem KW" Total Sens# tam KTotal tem KW'• Total Sens# tam KW" Total Sens# tam KW" Outdoor 72(22.2) 41.02 21.66 2.54 39.40 21.07 2.83 37.67 20.45 3.14 35.71 19.75 3.48 33.44 18.95 3.91 67(19.4) 37.34 26.81 2.53 35.82 26.20 2.81 34.20 25.55 3.11 32.39 24.83 3.45 30.24 23.98 3.87 w 1050 63(17.2)}} 34.68 25.78 2.53 33.23 25.15 2.81 31.71 24.49 3.10 29.97 23.75 3.44 27.94 22.89 3.85 62(16.7) 34.09 31.81 2.53 32.69 31.14 2.81 31.25 31.03 3.10 29.79 29.79 3.44 28.17 28.17 3.85 57(13.9) 33.44 33.44 2.53 32.31 32.31 2.81 31.10 31.10 3.10 29.74 29.74 3.43 28.12 28.12 3.85 72(22.2) 41.67 22.87 2.60 40.00 22.2E 2.90 38.19 21.64 3.21 36.16 20.93 3.56 33.84 20.12 3.98 67(19.4) 37.97 28.72 2.59 36.42 28.10 2.88 34.74 27.44 3.18 32.86 26.71 3.62 30.66 25.85 3.93 1200 63(17.2)1t 35.32 27.56 2.59 33.82 26.92 2.87 32.24 26.25 3.17 30.45 25.49 3.50 28.36 24.62 3.92 62(16.7) 35.04 34.70 2.59 33.72 33.72 2.87 32.44 32.44 3.16 30.99 30.99 3.50 29.26 29.26 3.92 57(13.9) 34.87 34.87 2.59 33.67 33.67 2.87 32.39 32.39 3.16 30.95 30.95 3.50 29.22 29.22 3.92 72(22.2) 42.14 24.02 2.67 40.41 23.42 2.97 38.56 22.78 3.28 36.48 22.06 3.63 34.10 21.25 4.05 67(19A) 38.45 30.58 2.65 36.85 29.95 2.94 35.14 29.28 3.24 33.22 28.53 3.58 30.99 27.65 4.00 1350 63(17.2)tt 35.80 29.28 2.65 34.26 2B.63 2.93 32.63 27.95 3.23 30.83 27.19 3.57 28.68 26.27 3.98 62(16.7) 36.12 36.12 2.65 34.86 34.86 2.93 33.50 33.50 3.23 31.98 31.98 3.57 30.16 30.16 3.99 57(13.9) 36.07 36.07 2.65 34.81 34.81 2.93 33.45 33.45 3.23 31.94 31.94 3.57 30.12 30.12 3.99 DETAILED COOLING CAPACITIES# CONTINUED EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total! Capacity MBtuh Total Sys• Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- °F CC) Total Sens# tern KW Total Sens# tem KW' Total Sens# tem KW'• Total Sens# tem KW' Total Sens# tem KW** Outdoor Section With 42 Indoor Section 12(22.2) 48.49 25.49 3.39 4fi.39 24.69 3.73 44.1 B 23.85 4.11 41.83 22.97 4.52 39.28 22.03 4.98 67(19.4) 44.47 31.36 3.33 42.52 30.54 3.67 40.46 29.67 4.05 38.28 28.77 4.47 35.93 27.82 4.92 1225 63(17.2)tt 41.53 30.43 3.29 39.69 29.59 3.63 37.74 28.72 4.01 35.68 27.80 4.43 33.47 26.84 4.88 62(16.7) 40.83 37.19 3.28 39.07 36.35 3.63 37.22 35.45 4.00 35.29 34.48 4.42 33.32 33.32 4.88 57(13.9) 39.73 39.73 3.27 38.29 38.29 3.62 36.76 36.76 4.00 35.12 35.12 4.42 33.34 33.34 4.88 72(22.2) 49.21 26.62 3.47 47.02 25.00 3.81 44.73 24.95 4.19 42.30 24.06 .4.61 39.67 23.11 5.06 67(19.4) 45.16 33.20 3.42 43.14 32.37 3.76 41.00 31.49 4.13 38.75 30.59 4.55 36.34 29.63 5.01 1400 63(17.2)tt 42.22 32.16 3.38 40.31 31.31 3.72 38.28 30.42 4.09 36.17 29.51 4.51 33.89 28.53 4.97 62(16.7) 41.69 39.75 3.37 39.91 38.85 3.71 38.02 38.02 4.09 36.34 36.34 4.51 34.45 34.45 4.98 57(13.9) 41.25 41.25 3.37 39.72 39.72 3.71 38.08 38.08 4.09 36.34 36.34 4.51 34.45 34.45 4.98 72(22.2) 49.75 27.70 3.56 47.50 26.88 3.90 45.14 26.02 4.27 42.64 25.12 4.69 39.94 24.16 5.14 67(19.4) 45.69 34.99 3.50 43.61 34.15 3.84 41.42 33.28 4.22 39.12 32.36 4.63 36.65 31.38 5.09 1575 63(17.2)tt 42.75 33.85 3.46 40.79 33.00 3.80 1 38.72 32.11 4.17 36.55 31.18 4.59 34.23 30.18 5.05 62(16.7) 42.49 52 42.08 3.46 40.87 40.87 3.80 39.14 39.14 4.18 37.31 37.31 4.61 35.32 35.32 5.07 57(13.9) 42. 42.49 3.46 40.a7 40.87 1 3.80 39.15 39.15 4.18 37.32 37.32 1 4.61 1 35.32 35.32 5.07 See notes on page 15 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F(°C) 75(23.9) 95(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- °F CC) Total Sens# tem KW'• Total Sens# I tem KW" Total Set s# tem KW Total Sens# tem KW' Total Sens# tem KW** Outdoor `-• 72(22.2) 53.87 27.47 3.18 51.45 26.27 3.59 48.92 25.05 4.07 46.25 23.82 4.61 43A1 22.56 5.21 67(19.4) 49.06 33.61 3.16 46.83 32.31 3.56 44.50 31.00 4.05 42.04 29.66 4.59 39.41 28.30 5.19 1275 63(17.2)tt 45.60 32.39 3.14 43.53 31.11 3.55 41.33 29.80 4.03 39.02 28.47 4.57 36.55 27.11 5.18 62(16.7) 44.79 39.62 3.14 42.76 38.21 3.55 40.64 36.76 4.02 38.42 35.26 4.57 36.16 36.16 5.17 57(13.9) 43.29 43.29 3.13 41.65 41.65 3.54 39.91 39.91 4.02 38.08 38.08 4.56 36.11 36.11 5.17 72(22.2) 54.71 28.64 3.23 52.22 27.41 3.65 49.5E 26.17 4.13 46.83 24.91 4.67 43.91 23.63 5.28 67(19.4) 49.84 35.47 3.22 47.54 34.13 3.63 45.12 32.78 4.11 42.58 31.40 4.65 39.90 29.99 5.26 1425 63(17.2)tt 46.35 34.12 321 44.20 32.79 3.61 41.94 31.45 4.09 39.55 30.08 4.64 37.02 28.68 5.24 62(16.7) 45.62 42.07 3.20 43.55 40.56 3.61 41.43 41.12 4.09 39.37 39.37 4.63 37.29- 37.29 524 57(13.9) 44.80 44.80 3.20 43.09 43.09 3.61 41.25 41.25 4.09 39.31 39.31 4.63 37.24 37.24 5.24 72(22.2) 55.37 29.76 3.29 52.79 28.51 3.71 50.09 27.24 4.19 47.26 25.96 4.74 44.27 24.65 5.34 67(19.4) 50.46 37.27 3.28 48.09 35.89 3.69 45.61 34.49 4.17 43.01 33.08 4.71 40.26 31.63 5.32 1575 63(17.2)tt 4696 35.79 3.27 44.74 34.42 3.67 1 42.42 33.04 4.15 39.97 31.63 4.70 37.38 30.19 5.30 62(16.7) 140 44.30 3.26 44.37 44.37 3.67 42.45 42.45 4.15 40.42 40.42 4.70 38.25 38.25 5.31 57(13.9) 46.10 46.10 3.26 44.30 44.30 3.67 42.39 42.39 4.15 40.36 40.36 1 4.70 38.20 38.20 5.31 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Teel Capacity MBtuh Total CFM EWB System System System System System System °F(°C) Total Sens# KW+* Total Sens# KW++ Total I Sens# ICW*• Total Sens# KW+• Total Sens# KW Total Sens# KW-- •,O Outdoor 72(22.2) 68.71 34.82 4.37 65.76 33.74 4.81 62.59 32.60 5.30 59.21 31.39 5.84 55.54 30.09 6.42 51.41 28.66 7.05 67(19.4) 63.16 43.00 4.29 60.43 41.90 4.74 57.50 40.73 5.23 54.39 39.50 5.77 51.03 38.20 6.36 47.32 36.77 6.99 1750 63(17.2)tt 59.15 41.80 4.24 56.59 40.69 4.68 53.84 39.50 5.18 50.92 38.26 5.72 47.79 36.96 6.31 44.36 35.54 6.95 62(16.7) 58.14 51.13 4.23 55.65 49.99 4.67 53.01 48.77 5.16 50.27 47.45 5.71 47.55 47.55 6.31 44.70 44.70 6.96 57(13.9) 56.63 56.63 4.21 54.60 54.60 4.66 52.42 52.42 5.16 50.09 50.09 5.71 47.55 47.55 6.31 44.71 44.71 6.96 72(22.2) 69.71 36.45 4.48 66.67 35.37 4.92 63.38 34.20 5.41 59.88 32.98 5.95 56.07 31.67 6.53 51.80 30.21 7.15 67(19.4) 64.15 45.67 4.40 61.31 44.55 4.85 58.27 43.36 5.34 55.05 42.13 5.87 51.58 40.80 6.46 47.74 39.34 7.10 2000 63(17.2)tt 60.14 44.30 4.35 57.47 43.18 4.79 54.61 41.98 5.26 51.60 40.73 5.82 48.36 39.39 6.42 - 44.82 37.93 7.06 62(16.7) 59.33 54.75 4.34 56.80 53.54 4.78 54.23 54.23 5.28 51.77 51.77 5.83 49.05 49.05 6.42 45.99 45.99 7.07 57(13.9) 50.75 58.75 4.33 56.59 56.59 1 4.78 54.26 54.26 5.28 51.77 1 51.77 5.83 49.05 49.05 6.42 46.00 46.00 7.07 72(22.2) 70.44 37.99 4.59 67.31 36.90 5.03 63.93 35.73 5.52 60.33 34.49 6.05 56.41 33.16 6.63 52.03 31.69 7.25 67(19.4) 64.85 48.20 4.51 61.94 147.09 4.95 58.82 45.89 5.44 55.52 44.63 5.98 51.96 43.27 6.2250 63(17.2)tt 60.84 46.68 4.45 58.11 .56 4.90 55.17 44.34 5.39 52.08 43.07 5.93 48.77 41.69 6.562(16.7) 60.44 60.44 4.45 58.18 .18 4.90 5572 55.72 5.40 53.10 53.10 5.94 50.2357(13.9) 60A7 60.47 4.45 58.19 .19 4.90 55.73 55.73 1 5.40 53.10 53.10 5.94 50.23 50.23 6.54 47.00 47.00 7.18 NOTES: *Tested combination. t Total and sensible capacities are net capacities.Blower motor heat has been subtracted. t Sensible capacities shown are based on 80°F(27°C)entering air at the indoor coil.For sensible capacities at other than 80°F(270C),deduct 835 Btuh (245 kW)per 1000 CFM(480 US)of indoor coil air for each degree below 80°F(270C),or add 835 Btuh(245 kW)per 1000 CFM(480 US)of indoor coil air per degree above 80°F(27°C). #Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008.If additional tubing length and/or indoor unit is located above outdoor unit,a slight variation in capacity U may occur. **System kw is total of indoor and outdoor unit kilowatts. tt At TVA rating indoor condition(75°F edb/63°F ewb).All other indoor air temperatures are at 80°F edb. NOTE:When the required data falls between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. EWB-Entering Wet Bulb NOTE:When the required data fall between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. CONDENSER ONLY RATINGS* SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 65(29.44) 95(35.0) 105(40.56) 115(46.11) TCG 16.90 15.70 14.60 13.60 12.60 10.5 1. 0 9.30 SDT 71.20 79.70 88.40 97.90 107.30 126.60 137.10 (- 11) KW 0.88 0.99 1.10 1.24 1.39 1.78 2.04 TCG 18.60 17.40 16.20 15.10 14.00 11.80 10.50 35(1.67) SDT 71.50 80.80 89.50 98.90 108.20 127.40 138.00 KW 0.86 0.98 1.10 1.24 1.40 1.78 2.06 40 TCG 20.40 19.10 17.90 16.70 15.60 13.20 11.80 SDT 73.50 81.90 90.60 99.90 109.20 128.70 137.60 (4�) KW 0.87 0.98 1.10 1.24 1.40 1.80 2.03 TCG 22.20 20.90 19.60 18.40 17.20 14.60 13.20 45 SDT 73.40 03.10 91.70 101.00 110.30 129.40 138.50 (7.22) KW 0.84 0.97 1.09 1.24 1.40 1.80 2.04 50 TCG 24.10 22.70 21.40 20.20 18.90 16.20 14.60 (10.0) SDT 74.30 83.50 92.80 102.10 111.40 130.40 139.50 KW 0.83 0.95 1.09 1.24 1.40 1.81 1 2.04 55 TCG 26.10 24.70 23.40 22.00 20.60 17.80 16.10 (12.78) SDT 75.50 84.80 94.00 103.30 112.50 131.50 140.30 KW 0.81 0.94 1.08 1.23 1.40 1.81 2.04 TCG 18.60 18.00 17. 30 40 16.60 15.80 14.90 13.80 (-1.11) EKW 78.20 87.90 97.80 107.70 117.70 127.80 138.10 1.03 1.19 1.39 1.61 1.88 2.19 2.57 20.60 20.00 19.30 18.50 17.60 16.60 15.40 35 79.80 89.50 99.30 109.10 119.10 129.20 139.30 (1.67) 1.04 1.20 1.39 1.62 1.89 2.21 2.59 40 TCG 22.70 22.10 21.30 20.50 19.50 18.40 17.20 (4.44) SDT 81.40 91.10 100.80 110.60 120.50 130.50 140.40 KW 1.04 1.21 1.40 1.64 1.91 2.23 2.60 45 TCG 25.00 24.30 23.50 22.60 21.60 20.40 1 19.10 (7.22) SDT 83.10 92.80 102.40 112.10 121.90 131.80 141.60 KW 1.04 1.21 1.41 1.65 1.92 2.24 2.62 50 TCG 27.50 26.70 25.80 24.90 23.80 22.50 21.10 (10.0) SDT 84.90 94.50 104.00 113.60 123.30 133.10 142.70 KW 1.05 1.22 1.42 1.66 1.93 2.26 2.63 TCG 30.10 29.30 28.30 27.30 26.10 24.80 23.30 55 SDT 86.70 96.20 105.70 115.20 124.80 134.40 143.90 (12.78) KW 1.05 1.22 1.43 1.66 1.94 2.27 2.64 TCG 26.40 24.90 23.20 21.70 20.20 18.70 17.10 30 SDT 71.50 80.00 88.80 98.10 107.40 116.70 126.00 (-1.11) KW 1.43 1.58 1.75 1.95 2.18 2.44 2.74 35 TCG 28.80 27.50 25.50 23.90 22.20 20.60 19.20 (167) SDT 71.70 81.30 89.90 99.20 108.40 117.70 127.20 KW 1.41 1.58 1.75 1.96 2.19 2.45 2.76 40 TCG 31.90 29.60 1 27.90 26.20 24.40 22.60 20.70 (4.44) SDT 73.40 82.00 91.20 100.30 109.50 118.70 127.90 KW 1.42 1.57 1.76 1.96 2.20 2.46 2.77 45 TCG 34.60 32.60 30.50 28.60 26.60 24.60 23.30 (722) SDT 74.50 83.50 92.50 101.60 110.70 119.70 129.40 KW 1.42 1.58 1.76 1.97 2.20 2.47 2.80 5o TCG 37.40 35.60 33.40 31.10 29.00 26.70 25.40 (10.0) SDT 75.80 85.00 94.00 102.90 111.90 120.90 130.50 KW 1.41 1.59 1.77 1.97 2.21 2.48 2.81 TCG 40.80 38.60 36.10 33.80 31.50 29.10 28.00 55 SDT 77.50 86.50 95.30 104.30 113.20 122.10 132.00 (12.78) KW 1.41 1.59 1.77 1.98 2.22 2.49 2.83 See notes on page 18 16 CONDENSER ONLY RATINGS* CONTINUED SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(--- 85(29.44) 95(35.0) 105(40.56) 115(46.11) 24A 30 TCG 30.70 28.50 .26.70. 25.10 23.50 21.90 20.00 (_1.11) SOT 70.70 80.00 89.40 98.80 108.20 117.60 127.00 KW 1.61 1.94 2.21 2.47 2.73 3.03 3.41 TCG 33.70 31.40 29.50 27.80 26.10 24.30 22.20 35 SOT(1.67) 71.80 81.1.0 90.40 99.80 109.20 118.50 127.80 KW 1.58 1.91 2.19 2.45 2.72 3.03 3.41 TCG 36.90 34.60 32.50 30.70 28.80 26.80 24.60 40 SOT 72.90 82.20 91.50 100.90 110.20 119.40 128.60 (4.44) KW 1.55 1.89 2.17 2.44 2.71 3.02 3.41 45 TCG 40.40 37.90 35.80 33.80 31.70 29.50 27.10 (722) SOT 74.20 83.40 92.70 102.00 111.20 120.40 129.50 KW 1.53 1.87 2.16 2.43 2.71 3.03 3.41 50 TCG 44.20 41.60 39.30 37.10 34.80 32.40 29.80 (10.0) SDT 75.50 84.70 94.00 103.20 112.30 121.40 130.50 KW 1.52 1.86 2.16 2.44 2.72 3.04 3.43 TCG 48.20 45.50 43.00 40.60 38.10 35.50 32.60 55(12.78) SOT 77.00 86.10 95.30 104.40 113.50 122.50 131.50 KW 1.52 1.87 2.17 2.45 2.74 3.07 3.46 30 TCG 38.00 36.00 33.90 31.90 29.70 27.60 25.30 (-111) SOT 73.20 82.30 91.40 100.60 109.80 119.10 128.40 KW 1.95 2.20 2.48 2.80 3.14 3.53 3.95 35 TCG 41.90 39.70 37.40 35.10 32.80 30.50 28.00 (167) SOT 74.80 83.70 92.80 101.90 111.00 120.20 129.40 KW 1.97 2.22 2.50 2.81 3.16 3.54 3.97 40 TCG 46.00 43.60 41.10 38.70 36.20 33.60 30.90 (4 44) 7.22) SOT 76.40 85.20 94.20 103.20 112.20 121.30 130.40 45 KW 1.98 2.23 2.52 2.83 3.18 3.56 3.98 TCG 50.30 47.70 45.10 42.40 39.60 36.80 33.90 SOT 78.10 86.90 95.70 104.60 113.50 122.50 131.40 ( KW 2.01 2.26 2.54 2.85 3.19 3.58 4.00 TCG 54.90 52.10 49.20 46.20 43.20 40.20 37.00 (10.0) 50 SOT 80.00 88.60 97.20 106.00 114.80 123.70 132.50 KW 2.03 2.28 2.56 2.87 3.21 3.60 4.01 55 TCG 59.70 56.60 53.40 50.20 46.90 43.50 40.10 (12 78) SOT 81.90 90.30 98.90 107.50 116.20 124.90 133.60 KW 2.06 2.30 2.58 2.89 3.23 1 3.62 4.03 TCG 39.10 37.90 36.60 35.10 33.40 31.50 29.4 30 0 (-30 SOT 72.80 82.00 91.40 100.60 110.00 119.20 128.40 KW 2.02 2.26 2.58 2.98 3.45 3.99 4.60 35 TCG 43.00 41.70 40.20 38.60 36.80 34.80 32.60 (167) SOT 74.20 83.40 92.60 101.90 111.10 120.30 129.40 KW 2.04 2.29 2.61 3.01 3.49 4.03 4.64 40 TCG 1 47.20 45.80 44.20 42.40 40.50 38.30 35.90 SOT 75.80 84.90 94.00 103.20 112.40 121.50 130.50 (4.44) KW 2.06 2.31 2.64 3.05 3.53 4.08 4.69 TCG 51.80 50.20 48.40 46.50 44.40 42.10 39.50 45' SOT 77.40 86.50 95.50 104.60 113.70 122.70 131.70 (7.22) KW 2.08 2.34 2.67 3.08 3.57 4.12 4.73 50 TCG 56.70 54.90 53.00 50.90 48.60 46.10 43.30 (10.0) SOT 79.20 88.10 97.10 106.10 115.10 124.00 132.90 KW 2.10 2.36 2.70 3.12 3.60 4.16 4.77 TCG 62.00 60.00 57.90 55.60 53.10 50.30 47.20 55 SOT 81.10 89.90 98.80 107.70 116.60 125.40 134.20 (12.78) KW 2.11 2.38 2.73 3.14 1 3.63 4.19 4.81 See notes on page 18 17 CONDENSER ONLY RATINGS* CONTINUED SST CONDENSER ENTERING AIR TEMPERATURES-FCC) °FCC) 55(12.78) 65(18.33) 1 (23.89) 85[29.44) 95(35.0) 105(40.56) 115(46.11) 24ABB360AON34 TCG 53.70 51.10 48.30 145.40 42.30 39.20 36.10 30 SDT 75.80 84.90 94.10 103.10 112.20 121.30 130.40 (-1.11) KW 2.65 3.00 3.38 3.78 4.24 4.77 5.38 TCG 5B.90 56.10 53.00 49.80 46.50 43.20 39.70 35(1.67) SDT 77.50 86.60 95.70 104.70 113.60 122.60 131.60 KW 2.72 3.06 3.43 3.84 4.29 4.82 5.44 TCG 64.60 61.40 58.00 54.50 50.90 47.20 43.40 40 SDT 79.40 88.40 97.30 106.20 115.10 124.00 132.90 (4 44) KW 2.79 3.13 3.50 3.90 4.35 4.88 5.50 TCG 70.60 67.00 63.30 59.40 55.50 51.40 47.30 45 SDT 81.40 90.30 99.10 107.90 116.70 125.40 134.20 (7.22) KW 2.87 3.20 3.56 3.97 4.42 4.95 5.56 50 TCG 76.90 73.00 68.80 64.60 60.20 55.70 51.20 (10.0) SDT 83.50 92.20 100.90 109.60 118.30 126.90 135.60 KW 2.95 3.29 3.64 4.04 4.50 5.03 5.64 TCG 83.60 79.20 74.60 69.90 65.10 60.20 55.20 55 SDT 85.80 94.30 102.90 111.40 119.90 128.50 137.00 (12.78) KW 3.05 3.38 3.73 4.13 4.59 1 5.12 5.73 *AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor(°Fr C) SST - Saturated Temperature Entering Compressor(°FP C) TCG- Gross Cooling Capacity(1000 Btuh) 18 GUIDE SPECIFICATIONS AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER 24ABB3 GENERAL 1-1/2 TO 5 NOMINAL TONS System Description Condenser Coil Outdoor-mounted, air-cooled, split-system air conditioner unit — Condenser coil will be air cooled. suitable for ground or rooftop installation. Unit consists of a — Coil will be constructed of aluminum fins mechanically hermetic compressor, an air-cooled coil, propeller-type bonded to copper tubes which are then cleaned, condenser fan, and a control box.Unit will discharge supply air dehydrated,and sealed. upward as shown on contract drawings. Unit will be used in a Refrigeration Comnonents refrigeration circuit to match up to a packaged fan coil or coil unit. — Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, Quality Assurance vapor-line shutoff valve with sweat connections, — Unit will be rated in accordance with the latest edition system charge of PuronO (R-410A) refrigerant, and of AHRI Standard 210. compressor oil. — Unit will be certified for capacity and efficiency, and — Unit will be equipped with filter drier for Puron listed in the latest AHRI directory. refrigerant. — Unit construction will comply with latest edition of Operating Characteristics ANSI/ASHRAE and with NEC. — The capacity of the unit will meet or exceed — Unit will be constructed in accordance with UL Btuh at a suction temperature of °F/°C. The standards and will carry the UL label of approval.Unit power consumption at full load will not exceed will have c-UL-us approval. kW. — Unit cabinet will be capable of withstanding Federal — Combination of the unit and the evaporator or fan coil Test Method Standard No. 141 (Method 6061)500-hr unit will have a total net cooling capacity of salt spray test. Btuh or greater at conditions of CFM entering — Air-cooled condenser coils will be leak tested at 150 air temperature at the evaporator at °F/°C wet psig and pressure tested at 450 psig. bulb and °F/°C dry bulb, and air entering the — Unit constructed in IS09001 approved facility. unit at °F/°C. Delivery,Storage,and Handling — The system will have a SEER of Btuh/watt or — Unit will be shipped as single package only and is greater at DOE conditions. stored and handled per unit manufacturer's Electrical Requirements recommendations. — Nominal unit electrical characteristics will be v, Warranty(for inclusion by specifying engineer) single phase, 60 hz. The unit will be capable of U.S.and Canada only. satisfactory operation within voltage limits of v to V. PRODUCTS — Nominal unit electrical characteristics will be v, Equipment three phase, 60 hz. The unit will be capable of Factory assembled, single piece, air-cooled air conditioner unit. satisfactory operation within voltage limits of v Contained within the unit enclosure is all factory wiring,piping, to V. controls, compressor, refrigerant charge Puron® (R-410A), and — Unit electrical power will be single point connection. special features required prior to field start-up. — Control circuit will be 24v. Unit Cabinet Special Features — Unit cabinet will be constructed of galvanized steel, — Refer to section of this literature identifying accessories bonderized,and coated with a powder coat paint. and descriptions for specific features and available — All models have dense grille. enhancements. Fans — Condenser fan will be direct-drive propeller type, discharging air upward. — Condenser fan motors will be totally enclosed,1-phase type with class B insulation and permanently lubricated bearings.Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. 19 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01-in.wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature is 115°F(46.1°C). 4. For reliable operation,unit should be level in all horizontal planes. 5. For interconnecting refrigerant tube lengths greater than 80 ft(23.4 m)and/or 35 ft(10.7 m)vertical differential,consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor. 6. If any refrigerant tubing is buried,provide a 6 in. (152.4 mm)vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in.(914.4 mm)may be buried without further consideration.Do not bury refrigerant lines longer than 36 in.(914.4 mm). 7. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 8. Do not apply capillary tube indoor coils to these units. 9. Factory-supplied filter drier must be installed. Copyright 2016 Carrier Corp.•7310 W.Morris St.• Indianapolis,IN 46231 Edition Date: 12/16 Catalog No:24ABB3-15PD Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. Replaces:24ABB3-14PD 20 I _ t PROPOSED SANITARY SYSTEM j SANITARY SYSTEM FOR 4 BEDROOM HOUSE 1150 GAL. SEPTIC TANK 400 S.F. SIDEWALL AREA OF LEACHING POOL (I POOL, 10' 0 x 13' DEEP) MEET ALL S.C. DEPT. OF HEALTH SERVICES REGULATIONS. FREDER]fCK SITE DRAINAGE: i SEPTIC t LEACH GREATER THAN 10' FROM STRUCTURE ROBERTWEBER ' FIN. FL. DRtt AREA VOLUME (Required) DRAINAGE STRUCTURES VOLUME (Provided) ItEL---+52.5'----- GRADE GRADE LOCKING CAST ARCHITECT (2) 8' Dia. x 4' Dee w/ ' IRON COVER GRADE A. B HOUSE t PORCH 1954 sf x .I66' Rain = 324.4 cf p 338 cf � EL +50' CO 4"0 APPROVED EL +50' TO GRADE EL +49.5' CONCRETE Traffic Bearing Top PIPE, 1/4" PER FT. COVER i C DRIVEWAY 2142 sf x AC Rain = 358.9 cf (1) 8' Dia. x 9' Deep w/ INVERT Traffic Bearing Top 380 cf i at HOUSE MIN. PITCH 4"0 APPROVED EL +48' _- o° PIPE, 1/8" PER FT. ---- O MIN. PITCH PROVIDE CLEAN OUT INVERT - 1 House and Porch Roofs to have Gutters t Leaders _ ® FACE OF HOUSE EL +41.5' �D LIQUID oo INVERT I INVERT _ t BARN TO GRADE FLOW EL +4T i EL +44.1' O Connected to Underground Drainage Structures (Typ.) BAFFLE SEPTIC I I WO Ring: 42.25 cf/Ft of Height I ��\\Q TANK it) i `r (1150 GAL. CONCRETE 1 COVER OR iIQ `�- 13, MIN. NEW C.I. GRATE ':z �r o �" < I LEACHING BEARING is L�� << 20 iCOLLAR POOL i �► SLAB PRECAST i �- > � 1 MOO S.F.) 1 �� 6 CHIMNEY TE \� �O.�F` \ DRAINAGE PIPE I TYPICAL O W I I I I DRAINAGE I V I ► �� I I �� RING `" y 1 I � �� �. ; 1 �) 10 I v l I ' 8'-O" I 10—0" '—0" I I 1 ; I i c ' 7 ' I (4) "ACER RUBRUM" n �I 3' (MIN.) TO HIGH 8'-O'� �, Ji I RED SUNSET MAPLES I � i SEASONAL GROUNDWATER i U� PLANTED 49' OC ALONG H'_ `.�i L---------------------------- 1 2 CLEAN SAND � � I �� i �, GRAVEL FILL -_- v TYPICAL SECTION ED DRAINAGE RING . TEST HOLE a� LOT 3 �' KEN WOYCHUK, L.S. VACANT DECEMBER 22, 2020 �I BROWN LOAM (OL) PROPERTY OWNER: BROWN LOAMY DANIEL HARBES ASPHALT TRAFFIC \ 0 / SAND ISM) MAP OF: PETER HARBES MAP TWO ��I Top eCoat BEARGRATEING i \ G / `o FILED: FEB. 14. 2022 NO. 12230 �,,, PIPE TRENCH \ I �/ I \ \ 4 a ao0 DRAIN TO �� �� OQ' �` BROWN MEDIUM SITUATE: LAUREL DRAINAGE RING �� y 1 \ Q"F �, \ TOWN OF SOUTHOLD 8" I \ Stockpile / SAND t GRAVEL (SP) SUFFOLK COUNTY, NEW YORK STONE ,4--1 �� Topsoil for / TE:5T mac, c, BLEND I Respreading �� HOLE o �i SURVEY INFORMATION: O �� \ Following 1 , EL 41.6' 9�, �rn KENNETH WOYCHUK C I \ Construction �� / ,v00' �F 0 2 AQUEBOGUE, NY CROSS SECTION 7 I-RENCH DRAIN 5 DRIVEWAY \ >y �� x °W �� SURVEYED: DECEMBER 22, 2020 �5` \ REVISED: MARCH 10, 2022 \\ , NO WATER +0.0' = ELEVATIONS REFERENCED TO NAVD 1988 DRAWING TITLE: C%bENCOUNTERED 11 T»z wA' ER SUPPLY, WELLS, DRYWELLS I 1 0"�� ��`� I v - SITE PLAN AND CA LOCATIONS SHOWN INLET ��� O� "' ARE FROM FIELD OBSERVATIONS AND OR DATA OBTAINED FROM OTHERS `'� -;ro. �, 'O `• ` . Gill �y '� e'0y b, ecle �9 SCTMU 1000-120-03-11.22 �o O��OSED WATERLINE. — — _ —� I ;: ::: ::: �� �� ..: ap�`,�e �� \ LOT AREA: 55,105.14 S.F. — T O Concret �, ON Washout t?�°Qati�°�yti�° �h� . \ PRO\POSED _ — —U3- — — O�� J Area G° ZONING: R40 WELL, — — — I I `: ': Fo hoc \ i50 Radws 00 < .j- p YARDS: (PRINCIPAL SETBACKS) JOBS FRONT 50' SIDE (ONE): 15' DAN HARBES ;.:. o. IN SIDE (BOTH): 35 RELOCATED _` / 1 REAR: 50' FILTER CLOTH AGAINST Q \ \\ ea�ay Stoop oQ�S - - ------ o RESIDENCE WOVEN WIRE FENCE W/ \ I �,c Q� ---- �—k LOT COVERAGE (ALLOWED): 20/ (MAX.) 2"x2"x36" STAKES, 12' OC I 1 ALORICH LANE. ,..... DRIVEN 14" MIN. INTO O Q �v \ �'''' PROPOSED HOUSE: 1434 SF GRADE, EMBED FILTER �� ti� I '' � c.0. 1 MATTITUCK. NY CLOTH 6" INTO GROUND 15 o x� 0 6 BEDROOM SYSTEM: V' LOT 2 D� ono z -I150 GAL SEPTIC TANK, FRONT PORCH: 48 SF I REAR PORCH: 444 SF TOWN OF SOUTHOLD O �, IO'� x 3.5 EFF. DEPTH It,O� �`adcu5 TOTAL: 1926 SF SCTM# 1000-120-03-11.22 I "g" (D 10'0 x 13' DEEP L.P. I `� `� T g I LOT COVERAGE (PROPOSED): 3.5% IR,O z C)i O / �\ �\ / �n,2J I �� ARCHITECT: FLOW jO O `� `�\ / L.P., I � YARDS: (ACCESSORY SETBACKS) � � I >y •� (LOT SIZE: 40,000 TO 59,999 SF) SLOPE z �� `� 20' WIDE \\ma`s / s I SIDE t REAR: 15' 41 EDERICK L WEBER EAST MAPLE ROAD GREENLAWN. NY 11'140 LANDSCAPE BUFFER: o EXP O� I 8 EXISTING CONTOUR TWO ROWS OF G) . I 52 NOYAC PATH CROSS SECTION O O �\ 6' EVERGREENS �� / �$ I 8 "" OLD CONTOUR WATER MILL. NY 11914 SILT FENCE DETAIL �� STAGGERED ROWS j`� ✓ s I 8 �� NEW CONTOUR _ 5555 0 `qo' OC / TEL 0 o I fweberarehite�ctOyahoo.eom LAND N/F OF PtE LLC TOWN OF SOUTHOLD �. / \�,-' - _ ______ __` SEAL: DEVELOPMENT RIGHTS / 22.11 ,ACRES (VACANT) Q Q �`�\ // LOT 1 VACANT O ` NORTH STORM WATER POLLUTION PREVENTION O � i 1" = 20'-0" BULDING,DEPT TOWN OF SOCITHOLD CONSTRUCTION PHASING: Q I- INSTALL SILT FENCE. 0 �+ fl' 2- POUR NEW FOUNDATION AND LOWER HOUSE ONTO FOUNDATION .� `� *� �- n� •sr� = 3- INSTALL DRAINAGE STRUCTURES AND NEW SANITARY SYSTEM O `� 't ,�J�����t' ��`' °�`°p` J ;- !l • D( DAT � -1L B.P.# Us� ��s IS UNLt1��FQ1.. }.r REV.: 4- FRAME PORCHES AND INSTALL ROOFING MATERIAL. / - DRAWING SCHEDULE 5- PROVIDE GUTTERS/LEADERS AND CONNNECT TO DRAINAGE STRUCTURES. �� O O ��\ c FEE: 6���1J gY; rJdITHQll�' CERTIFICATE DATE: JUNE 3. 2022 1 NOTIFY BUILDING DEPA:ITMENT AT DESCRIPTION BUILDABLE SITE AREA: 55,105 5F, LAND DISTURBANCE: 12,000 SF \ 765.1802 9 AM TO 4 Pid FOR THE JF occup.,AINIC`� RETAIN STORM WATER RUNOFF SCALE: I" a 20'-O" Q FOLLOWING INSPECTIONS: PURSUANT TO CHAPTER 236 Al SITE PLAN EXISTING CONDITIONS: SITE IS MOSTLY CLEARED AGRICULTURAL LAND AND FLAT IN THE AREA OF `< 1. FOUNDATION - Ts�:c� REOUIRED JOB NO: w202108 CONSTRUCTION t DRIVEWAY. TOP SOIL WILL BE STRIPPED, STACKED AND RESPREAD. CLEAN so . FOR POUREDCONCHt:7c OF THE TC."l'i'i CCCE. A2 FOUNDATION PLAN FILL WILL BE BROUGHT IN FOR SANITARY SYSTEM ;AS REQUIRED, BUT EXPECT EXCESS FILL -' ' 2 ROUGH - FRAMING & PLUMBING A3 IST FLOOR PLAN FROM BASEMENT EXCAVATION, SANITARY SYSTEM AND DRAINAGE STRUCTURES WILL BE REMOVED. 3 INSULATION <��'iv�l-�I.'�` `�.l `-I ni_L CC`DC-SO- FROM NO. <. , 0 1-r �.._ T ;�; , ;�r.,•-...____-- A4 2ND FLOOR PLAN CONSTRUCTION ENTRANCE AND STAGING WILL BE IIN THE AREA OF THE PROPOSED DRIVEWAY. , ,�;�CiO .: 4 FINAL - CONSTRUCTION MUST :�vJ YGtt:� v I IA 1 - � OWiJ COLD _,A-,••�„ BE COMPLETE FOR C.O. �;� `AL%.O ;, '�, ,." ; ;0 CONDITiC'.4 OF PLUrt°gCR CERTIFICATION A5 ELEVATIONS (EAST/WEST) �''�``'" `C"`' � ALL CONSTRUCTION SHALL MEET ON L,.:,A() CONTENT BEFORE EXCAVATION/FILL ;. G` �+ : :E:quire THE REQUIREMENTS OF THE N.Y. , n . d'�,i,�� TG�'�;d1 A6 SECTIONS Q CERTIFICATE OF OCCUPANCY STATE CONSTRUCTION & ENERGY SOLDER USED /N WATER EXCAVATION FOR NEW BASEMENT/SANITARY/'DRYWELLS = 500 CY CODES. NOT RESPONSIBLE FOR BACKFILL OF PORCHES = 50 CY DESIGN OR CONSTRUCTION ERRORS I�14T01��J1i;�,i c3, SUPPLY SYSTEM CANNOT SI 2ND FRAMING (IST FLOOR) �irG REGRADING AROUND HOUSE # PORCHES = 100 CY � „•I.S,GEC EXCEED 2110 OF 1%LEAD. OF A6 FREDERICK ROBERT WEBER ' ARCHITECT A W (Existing z 32'-9" FAH r 4 U� Steps I to GGrade I J -________________________________________-.----__-_______- ______ r� I I .--- --------------------. -- -----------------------, I - -- -- /'� ------------------- UNE,XCAVATED 8" ► Neu 4" Thick P. Conc. o I I Slab iw/ VX0 10/10 o I 1 New 8" P. Conc. I WWF Reinf. (Above) o Found Wall w/ (2) u5 Bars (Top ( Bot), 3'-001 I Hounch Slab Edge _L 00 Ist Belou Grade (Min.) on I I e: Support on q Wide 20"x10" P. Conc. Ftg., I I Foundation Ledge w/ (3) tt5 Bars I I I I Hinged I I A wm. Orate _ I I I I = ----=------------------ I Bluestone ; ��+ _ _ - --------------- ---------------------------- Cap it I aA `tGF1 I I I I I I P. Conc. P. Conc. v Egr ss I I T--- Pier (Tgp.) I I Areaway -H o „ Wind w I I 13'-2" I'-4" r——————— I I o - I I Existing Dram to � - I I 2" Closed Cell Chmne -------t t FluesOrywell 53rag Foam Insul., R w/ L Fireproof Coating (Typ.) 1 I DRAWING TITLE:Gravel in Note: Window Sill 1 1 - I I I I -----� I 3ASEMENT I I 24"x 28.15" � Bottom of `1' to be 44" ,above I I I Plastic Drgwell Areaway Bsmt. Slab (Max.) I t------rt 1 �j I Gas-Fir d ❑ FOUND,4TION I I I u- Boiler 1 (NOS FW,4S24) = B mt. I i-----i I _ _N in I x L____J (V I ❑ I d- I I 1 New 4" Thick P. Conc. I x °p v 1 rn 51A w/ 6"x6" 10/10 � � Existing (!�e t ❑ I I I I NVJF Rein'. (Above) �' Mechanical ' Space rEGRESS UJINDOUI DETAIL - I X p lo" �T�p of slab x - � I O a I I P.Conc I cy O Stair I - w to Bottom of F.J.) I _� w I I 111 ICI I I q _6„ 9'-6" �, 0,. 6 -10" I _ I I (Hand oN II I Rail o— —I — — r--t —� —I•— I II _ II JOB: 18 x18 Slteel Girder SCOPE OF UJORK:ing W 8 x8 Steel 1Girder I Existing W OAN !HAR5 J --•—•-- •—•---•—+•- — •—•— o— —•—• —•— `s' I I 1 I I New I I I I I I Beam I I I- PROVIDE NEW POURED CONCRETE FOUNDATION WALLS AND FOOTINGS WITH REINFORCING RELOCATED Beam i I IPi h Sla tin I cket L--- J 3 I/2 Stee(L 1. _ -_J New1 __ __ 1 L----�, I/4" Pocket I I STEEL AS INDICATED ON THE FOUNDATION PLAN. RESIDENCE . 1 16"�e e 6"1 2 Plppe Column on 3 I/2"0 Steel t J '�` + �F?ram PI o 30 x 0 xl5 I I 2- VERIFY ALL DIMENSIONS FROM BELOW EXISTING HOUSE STRUCTURE INCLUDING CHIMNEY ,QLDRICH LANE 1 0, Pipe Column on v I Ito r w%1111 I P. C c. Ftg. p" " " _ I I BEFORE FORMING AND POURING FOUNDATION WALLS. MATTITUCK, NY I I y Reinf. P. Conc. Hdr. w/ (3 tt5 Bars 36 x36 A ooII 1 P. Conc. Ftg. o I I 3- ALL NEW POURED CONCRETE SLABS SHALL HAVE 6"X6" 10/10 WWF REINFORCING.Existing 2x8 - I Both ags (Typ.)Sill fE r---J --- I w/ (3) 45 Bars w W8 x18 I TOWN OF SOUTHOLO New 2x8 Sill T ° Smoke/CO Both Ways I °O ° (8 1/8"x5 1/4 x 5/14" 1 I �4- EXISTING IST FLOOR FRAMING TO REMAIN "AS IS". REVIEW FOR DETERIORATION AND REPAIR. SCTHS 1000-120-03-11.15 (2) u5 Bars L a--1- 1 PressureOTreated Detector 0 I I 5- PROVIDE NEW STEEL PIPE COLUMNS AS INDICATED. �I'-0"�I'b 8" 3'-8"- 10" I - ARCHITECT: 1 (�' Subframe for ---- 1 I 6- VERIFY CONDITION OF EXISTING STEEL GIRDER.(Extend IS" I I Doors t Windows i i Beyond Opng.) `r O i 1 I UNEXCAVI I (Typ.) LL r, ----T- I L I I II I FREDERICK R. WEBER4 Stirrups in 3 o —" FOUNDATION NOTES: 41 EAST MAPLE ROAD rr_r GREENI-AWN. NY' 11140 i- CONCRETE TO BE 3500 PSI AFTER 28 DAYS. (2) tt5 Bars L_ 2=0' 4'-8" 1 0" 1 x 4„ - cv 1 x PressureOTreated 1 0 I 52 NOYAC PATH I 2- ALL FOOTINGS TO BE A MINIMUM OF 3 0 BELOW GRADE. WATER MILL, NY 1197E (Extend 18" I w - �;' w Subframe for I I 3- ALL STEEL GIRDERS BEARING ON P.CONC. y pg. _ I I To 4Ladde, 00rs t Windows 1 1 FOUNDATION WALL TO HAVE 4"x6"A/2" B.PL. Be and O n ) New 10 P. Conc. 1 TEL 431 '154-5555 O I 1 s I (Typ.) I I (UNLESS OTHERWISE NOTED) fweberarchitecta ahoo.com 3" 4" 3" � Found. Wall w/ l2) u5 I cn y �„ Bars (Top t Bot) t I 1 5'-3 I/4" A d t s xistingv 1 I 4- ALL COLUMNS TO HAVE VAO"A/2" B.PL. ,46 Bars, fo I s t. Stair 33"oc Vert. on I I Rei f. P. Conc. Hdr. ca_:�Z_7 Reid. Hd I I (UNLESS OTHERWISE NOTED) 20"x10" P. Conc. Ftg., I ---- :------------- __ - _-: _ -- - -----_4--- ------ - --------J I 5- STEEL SHALL BE ASTM A-36 (EXCEPT SEA CONCRETE HEADER ITYPJ w/ (3) 45 Bars PIPE COL WHICH SHALL CONFORM TO _3/4" = F-0" L _ __ - _ 1 ASTM A53 ROUND PIPE). STEEL WORK SHALL r-- Gravel- ,''-------- v _ f--------- ` r-- i'------ CONFORM TO THE LATEST AISC SPEC.Sal T e SP I ----- -- 1gp NEw Stoop1 I 6- DOUBLE ALL FLOOR JOISTS AND FRAMING UNDER Wall Thickness: 10" ___ /Wall Height: 10'-0" ,� 1 8" ' " 8" d I Uh,EXCAV. � I 1 8" 18" PARALLEL PARTITIONS AND AROUND ALL OPENINGS. Backfi11 Height: 9 -0 Max. I _ ___ I I 8„ I 6_8 I g I 1 L__ _ ___ I f� 1 "' 1 I I I I I 1 I L----- — ———————— — I I L-------- --� 1 L----- — --------- ., I P. Conc. -2 1 I P. Conc. Window Well I -- New __ _ I Window Well fi atCPS —I I 4'-2" l'-8" REV.: Ir ,q DATE:: JUNE 3. 2022 SCALE: 1/40 - KEY: FOUNDATION PLAN JOB NO: w202108 ac p DRAIUING NO. New Foundation Wall z .A2 OF AL WINDOW SCHEDULE FREDERICK Unit Model # R.O. (Width E Height) Area g Egres ROBERT WEBER ® CWI35 T-4 1/8' x T-5 3/8" No © CX24** 5-3 1/4"x T-0 1/2" Yes ARCHITECT Model Numbers Refer to "Andersen" 400 Series, High Performance Low-E4 Glass, PG 50 Performance, Simulated Divided Lights, Plywd. Panels for Impact, Full Screens ** Straight-Arm Operator For Egress A r, A6 DOOR SCHEDULE Unit Model # Width t Height z 0 Front Door w/ 3'-0'x C-8' (Door) Sidelights t Transom (2) I'-2"x C-8" ("Simpson") * Sidelights (Z) 3, 131 -10" 13'-10" " 13'-10" 3 O "Thermatru', S2105 3'-0' x C-8' (Door) (Basement) FT W I--'--I -------------------------- -------------------------- -------------------------- * Review Width w/ Stair Treads II I I I I II II I I I I New RC II o II li — II II II II 1 1 1'-10" 6'-0" Existing 2'-8" 6'-2" 2'-4" IL.II"1 10!I I I , �:i Existing C56 BOW, (5) L' Hgt. I I I I Existing EXIStIn I I ,({�� Door CW13 I I GENERAL NOTES: I I `Nw.P. OUR :fl THE HOUSE IS AN EXISTING STRUCTURE WITH A "CERTIFICATE OF OCCUPANCY" 4 -8" WHICH HAS BEEN MOVED FROM ANOTHER LOCATION IN THE TOWN OF SOUTHOLD. 0 32" A NEW FOUNDATION AND SUPPORTING STRUCTURE WILL BE CONSTRUCTED ' ON THE SITE CONFORMING TO THE 2020 RESIDENTIAL CODE OF NEW YORK ^ m ExistingAstig STATE. HOWEVER THE EXISTING STRUCTURE WILL REMAIN "AS IS" AND NO24„ MUDROOM CERTIFICATION IS MADE AS TO ITS STRUCTURAL INTEGRITY OR CONFORMANCE 24" TO THE ENERGY CONSERVATION CONSTRUCTION CODE. ALL NEW FRAMIING CON " 15 -2 4" 12'-II" 4" I'-II" 4" 8'-5" r 6" 6" WORK INCLUDING NEW PORCHES, MINOR RENOVATIONS AND WINDOW/DOOR REPLACEMENT WILL CONFORM TO REQUIRED CODES. WHERE RENOVATION Existing WORK OCCURS AND POSSIBILITIES EXIST TO UPGRADE THE STRUCTURE CA THEY WILL BE UNDERTAKEN INCLUDING STRAPPING AND INSULATION. - BE:DROOM I Existing Guard Hand Smoke LIVING RO M �r O NEW WINDOWS TO BE "ANDERSEN" 400 SERIES WITH A MINIMUM PG50 RATING DRAWING TITLE: Rail Rail Detector ---- AND LOW-E4 GLASS WITH ARGON. . (Typ.) _° �., ---- I NEW EXTERIOR WINDOWS SHALL HAVE PROTECTION FOR WIND-BORNE DEBRIS IST FLOOR 3'-3 5 -6 2 -II 4" 3 2 I __ - ge0 ____ CONSISTING OF WOOD STRUCTURAL.PANELS WITH A MINIMUM THICKNESS _ <r .�, I e I OF 1/14" AND A MAXIMUM SPAN OF 8'. ATTACHMENTS SHALL BE 2 1/2" -� _1 M. T. I O -� � 1 48 6OOD SCREWS, id" OC FOR SPANS UP TO 4' AND 12" OC FOR SPANS 11 1 I'-9" , 3 -0" 1'-9" __ OR ALTERNATE THREADED ANCHORING DEVICES. R f.1 Existin o I KITCHEN "' i I IF NEW ROOF SHINGLES ARE INSTALLED, RIDGE STRAPPING SHALL BE Areawa o -� DWG PROVIDED AND ROOF SHINGLES SHALL BE HIGH WIND NAILING, 130 MPH. �-+ Smoke/CO 2' 01' 3'-10" 3'-0" 3'-4" '�-J New If NEW SIDING IS INSTALLED, PROVIDE WALL STRAPPING WHERE POSSIBLE. Detector All Other Spa :al Window JOB: ,r Existing Electri al _ r r+ Ln �, - II'-8" 4" 30„ 1 Sink ® � D.►4N H,4RBES New I RELOCATEDExisting `r BATH ---------- --- �' Island)_ ____�_ RESIDENCE CID 01 Cabinets ALDRICH LANE ' t Sink Remov MATTITUCK. NY O O � _ Existin TOWN Door SCTM 0 000 120-03D--11.15 -------- �- Tel i Existing Door 32,E Q - ARCHITECT: Ln New Stoop 15'-2" 4" T- " 424,. T-3" 4" 4" 14'-3" 6" FREDERICK R. WEBER t Steps Existing -`;" 41 EAST MAPLE ROAD - Existing = GREENLAWN. NY 11140 SITTING Existing �+ 0 FOYER o DINING ROO 52 NOYAC PATH - WATER MILL. NY 1191L rn 2�{" On li— n I N = En 4'-8' 3'-2" 8'-1" to U TEL L31 'I t g5555 3'- ' u, 2'-6" 8'-1" 3'-2" x � ' fweberarchitects' ahoo.com L/O � STEAL: _ .r. T,----- _----T� rT----- —:-- —rT Newl Door II II I I I I f ... I I II II E -tingExistin sC3ew 4 5-2045-C35-20 ;� COVERE STOOP a P 1 9'-4" ®------I------® Aer— `Y Steps .__._. KEY: Existing Frame Wall 8'-0" Existing Wail Removed R.EV.: A A6 ---= New Frame Wall DATE: JUNE 3. 2022 SCALE: 1/4" IS II FLOOR FD � � � JOB NO: w202108 p DRAWING NO. A3 OF A8 WINDOW SCHEDULE FREDERICK Unit Model # R.O. (Width ( Height) Area Egress ROBERT OprigWEBER ® CW135 T-4 1/8" x V-5 3/8" No © CX24** 5-3 1/4"x T-0 1/2" Yes ARCHITECT Model Numbers Refer to "Andersen" 400 Series, High Performance Low-E4 Glass, PG 50 Performance, Simulated Divided Lights, Plywd. Panels for Impact, Full Screens ** Straight-Arm Operator For Egress A rT, A6 DOOR SCHEDULE � Unit Model 4 Width i Height z Front Door w/ 3'-0"x C-8' (Door) Sidelights i Transom 12) I'-2"x C-8" ("Simpson") * Sidelights EZ) O2 "Thermatru", 52105 3'-0' x C-8" (Door) (Basement) W ...... --------------------------------------------------- ------------------- * Review Width w/ Stair Treads :F:F-: :: -------===---------------------------_---------------------------�::i: ------------------- ...... ...... I I II II w II II I I I 1 I I I I New Porch Roof 2 -6 4 I II II II II I I Existing Existing Existing I I I I C35 C45 BOW, (4) 5' Hgt. C35 II New L.C. Copper Roof New L.C. Copper Roof I I GENERAL NOTES: THE HOUSE IS AN EXISTING STRUCTURE WITH A "CERTIFICATE OF OCCUPANCY" WHICH HAS BEEN MOVED FROM ANOTHER LOCATION IN THE TOWN OF SOUTHOLD. A NEW FOUNDATION AND SUPPORTING STRUCTURE WILL BE CONSTRUCTED 1 I ON THE SITE CONFORMING TO THE 2020 RESIDENTIAL CODE OF NEW YORK o I 8._2. STATE. HOWEVER THE EXISTING STRUCTURE WILL REMAIN "AS IS" AND 140 (—I i IL CERTIFICATION IS MADE AS TO ITS STRUCTURAL INTEGRITY OR CONFORMANCE - TO THE ENERGY CONSERVATION CONSTRUCTION CODE. ALL NEW FRAMING WORK INCLUDING NEW PORCHES, MINOR RENOVATIONS AND WINDOW/DOOR rn REPLACEMENT WILL CONFORM TO REQUIRED CODES. WHERE RENOVATION Ex 1 30" Egg OC WORT; OCCURS AND POSSIBILITIES EXIST TO UPGRADE THE STRUCTURE THEY WILL BE UNDERTAKEN INCLUDING STRAPPING AND INSULATION. 3 : Ex DRAWING TITLE: 0 30" i Z NEW WINDOWS TO BE "ANDERSEN" 400 SERIES WITH A MINIMUM PG50 RATING Existing AND LOW-E4 GLASS WITH ARGON. Electrical NEW EXTERIOR WINDOWS SHALL HAVE PROTECTION FOR WIND-BORNE DEBRIS 2NO FLOOR mM to Remain CONSISTING OF WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS - ❑ OF 1/14" AND A MAXIMUM SPAN OF 8'. ATTACHMENTS SHALL BE 2 1/2" 4, 2' 10" 4' : II'-10" 4" U i 48 WOOD SCREWS, 14" OC FOR SPANS UP TO 6' AND 12" OC FOR SPANS °- Existing j Existing Existing a Oil ALTERNATE THREADED ANCHORING DEVICES. BEDROOM 3 BEDROOM 4 - BEDROOM 3 - IF NEW ROOF SHINGLES ARE INSTALLED, RIDGE STRAPPING SHALL BE PROVIDED AND ROOF SHINGLES SHALL BE HIGH WIND NAILING, 130 MPH. E>q Ex IF NEW SIDING IS INSTALLED, PROVIDE WALL STRAPPING WHERE POSSIBLE. C1�. 36'j- = Smoke JOB: 0, Detector _ __ -L-- -,O - -- ------Line-- Existing Ridge ------ - DAN HARBES - ------- - -- � p lTyp.) � I ------------- 30,E ---- 3x I Ex RELOCATED RESIDENCE Relocate " Existing Ex W.C. O Smoke/CO �- HALL 30" AL.DRICH LANE Ex Detector Q 1 C MATTITUCK. NY 301, �+ x s i Smoke x N TOWN OF 50UTHOLO Ex Detector w U SC:TM# 1000-120-03-11.15 30" :- - - - Q (TypJ 'I _ Remove 3'-6" 4 5'-10' le ARCHITECT: Existing Existing" Flat Clg. Existing i � `„- Ex and hower LAUNDRY �16 10 AFFi Skylights � M FREDERICK R. WEBER I N. �_ _ _ _ `�' Aeiifove\Step 41 EAST MAPLE ROAD ---- ------ --- Line of Clg. Break_ _= --- ---F--- --- GREENLAWN, NY 11140 Ex X Exist[ ' D Front Ex 1 ` WATER MILL. NY 119'IL 1 ` Load 52 NOYAC PATH CL. '/ I UPPER :FO ER 1 - 4 Countertop -� v / - TEL L31 �54-5555 Above fweberarchitectayahoo.com I I O I -m I SEAL: Existing I I i I Existing C 2.4 I I I I C 2.4 BagBelow eow I I I ► Bay Blow - f 2' New P rch Roof 1 I T-O" T-O" I i I I I I I I • i 4'-8" 6'-6" 21'-8" 6'-6" 4'-8" Existing Dormer Existing Dormer KEY: Existing Frame Wall Existing Wall Removed REV.: A A6 - New Frame Wall DATE: JUNE 3. 2022 2ND FLOOR F) A N :KALE: 1/40 - 1'-0" JOB NO: w202108 1/4" _ I._(Y o DRAWING NO. OF A8 Existing Brick Chimney FREDERICK ROBERT WEBER 12 - - - - - - Remove j I Ir- li it Skyllght Ex I 1 • � I I ` Existing Gambrel Roof Break - -- ------ ----T------------------------------- - --------- - --——————— ——————:--———————————————————————————————, —————————— -- - - - - - - - - —I � — - - - - - - - - - - - - - - - -r,- - - - - - - - - - - - - -- - -- - - - - -- -- - - - - — — - - - - - - - -- - ARCHITECT I 1 I R/e-ARaopohfa Existing fe House ou s�e ............................. ........ ....... I I +i II , � ............. (High Wind Nai ng) �1 .. I I I I II I II xi tin I I I 1 I i I I 21'7:8 I I I FW, I in ow "NuCedar" Siding I I I (5" Exposure) 11 I I I I I I rn I 12 O12 New I - o=E ' 1III Covered I - ................... ....Stop I ............ . New Porch ------------ - ROOF w 1I Exlstin———————— ———— _ —_------------_—_ --_-----1-------- - L D Width,±) —————-------=-------- — —————T --------- JIIII1 ----1III -II1II IIIII IIIIII IIIIIIIIIII ----------- I Porch Column. IIIIIIII1IIIiI III IIIIIIIII1ItIIIII I{IIIIII.IIIIIIIIIILIIIIII...._..._...=-...=.-.._...iii.... ..-..,�..._.., . ====IIIIII1I II 1I1IIIIIjI IIII1I uII u1I II --i�iII LIIIIIIII ................. IIIIIIIIII II II1III IrI IIII1II 7 III1IIIIII IIIIIIII1II ............-..1IIIIIIIIIII ....Enclose 6x6 Pressure Treated Post in Tapered xi tin xi Square "Versatex" in in Exi tin I I N tin Trim (Typ,), Strap a o s D r t Sideli h I I a ow Bolt Header t Anchor "NuCedar" Siding Post Base to Foundation \ (V Exposurs) IED 1�ffi� Guard Rail 3' Hgt. (Min.) . 1IIII1i'IJ ' z Hand New Bluestone ai Porch Floor i=== - _ - -------------=----------------- w e rr - - - -i- ------- lr r- r_ = _� _ _ , P. Conc. Stt 4 I)I" Areaway 6'_3 1L------- _JIL_ IL;_1_JIiIL_1_JI 11 1 I E Egress Windows,I I I II BBOIII Bluestone Cap on L I j------- 1 (15) Risers1/2" L`J ------- I 1 1r-T *IF-T-11INeW 11LJ (I4) Treads 10" I:I I all w/Hin ed p I Grate _ L2OI I L-------J JL L _ _i_ -- _1 L 3 - " J r-------� I r ------� r------- j ------ r I I ---- ---------- ---------J 1 I ------- ----i�- ------------------ r rJ•iv I I ---------- I ---------------------------------------I ----------L ------- Drop Footing a i I _1----- 1 ,1 Basement Areawa1--'— r I II I1I iIII I --————————— r L4 I L_ J L _JEB r EAST` ELEVATION SOUTH ELEVATION IItr DRAWING TITLE: xisting rck of House ELEVATIONS of Window? ��Re-Roof Existing House sphalt Iw/ Shingles, (High Wind Nailing) —————————— — ————————————————— —————————— --————————— -- — ------ ----I —I111II11I , ------------------------------- ----- -- --------- ,---------------- ._................ mow `� 5toneIiIIIIII1I .-...-...-...--------- ---------- Ii1I 1........ .-...-...-. --------_-_------------------ -- I1IIIIiI11IIiI1I III I.1IIIII i=.iI1II'I ORAENE HAAU IRIr BtN ...Y E S. ............ ............. RELOCATED Exi in RESIDENCE Exi tin 5' all Exi tn I w xi tin( In °wo ow ALDRICH LANE "NuCedar" Siding MATTITUCK, NY G" Exposure) I 12 j L.C. Cdpper TOWN OF SOUTHOL LLIDSill aWindows ........... SCTM# 1000-112-01 O—? --______- New Porch New Asphalt Shingle -_-__®== ROOF ROOF w/ Hih Wind � ARCHITECT. _------ ------ - ------------1 _-__----------W�==o = -.L j.___ nlr----- 1 - �Fng g �____- r-------------- -------- ----- --------- 1 ----- --------------r _ ______ _ , --------------------------- - ------- -- - ---------------------------------------- ki u FREDERICK R. WEBE A . ............................Jr . ............... ........................... '•••�����'•�•••�....•""'.•.••""•.• uu ----- L GI EAST MNPRPorch Column, ..... . ........... Enclose 6x6 Post Cap II/Eis New Pressure Treated xi t 52 NOYAC PATH Window Post in Tapered "NuCedar" Siding E tinem ve A 1 I WATER MILL NY 1191 L n Square Vr r (5 Exposure) Ez ti g in ow eworcoumn, iOCO I Exi tin Enclose dxd Existing I Trrim (T p.), Stap to \ TEL L 1154-5555 _ _ JI I Chimney Header t Anchor BoltOU ow� Pressure Treated III Post Base to Foundation Post in Tapered I'weberarchiteet5gahoo.eO o m JILLJSquare 'Versatex Trim Typ.) t SEAL:Ixd Pos Bluestone Base luestone Porch orcPh Floor ______ --————————————————————————— ——— - --- --————— ————————IL -_IIII`— - -------- ---------- - ---------� -----V--e--ee-r o-n-P-T-cT---Wa-ls-T-bo-v-e-�-a-`d-V--5t-oo-ps7-5-te-ps---------------------------------------------------------------I�II I= cY New ChimneyJ L--+----- ---------------J---------------------------------------------------------------IIIII II1--�I�iI IIII II I1 J Base REV.: IL-------------------------- --- -------- --------- J I I -LT————————————————————————— ^ i---- ------- C---------- --LvlL, r L-----------------------------------------------------------------------------------J L, DATE: JUKE 3. 2022 i _ ---------------------- I SCALE. JOB NO: w201512 NORTH ELEVATION WEST ELEVATION DRAWING NO. OF AS, w A5 P SIMPSON LSTA - 20 GAGE RIDGE STRAP - ALL ROOF RAFTERS 2 x 6 TIE 0 EACH RAFTER ICE SHIELD UNDERLAYMENT FREDERICK REQUIRED - 24" FROM EDGE ROBERT HURRICANE CLIP WEBER TYPICAL. ALTERNATE POSITION OF HURRICANE CLIP USE SIMPSON H3 ARCHITECT SIMPSON H2 HURRICANE CLIP NAILED. FROM PROVIDE 8d COMMON MST31 METAL STRAP RAFTER TO STUD. - NAILS 0 4" O.C. AT w/A4LL JACK POSTS TYPICAL ALL RAFTERS EXTERIOR EDGE OF ALL 8d NAILS EACH END - TYP. 5 - 8d NAILS EACH END SHEATHING. SHEATHING TO LAP TOP WALL PLATES APA RATED PLYWOOD TO EXTEND TO TOP OF TOP PLATE. 4 - 8d NAILS MST31 METAL STRAP TYPICAL -- /3 JACK POST MST21 0 STUDS w/ 4 - Sd NAILS 948" O.C. SIMPSON MST21 EACH END - TYP. 1 1/2" WIDE - 12 GAGE METAL STRAP $32" OC. z FLOOR JOIST MAXIMUM. r , DOUBLE TOPSJ Q PLYWOOD SHEATHING PLATE TO OVER LAP BOX HEADER 2 x 6 316" O.C. BEAM - TOP + BOTTOM. V 1 STUDS SIMPSON MTSA 18-Z W/ w (6) 8d NAILS TOP t NOTE : BOTTOM 0 32" O.C. PROVIDE FOUNDATION STRAPPING. ELEVATION W �SIDI G t PROVIDE PROVIDE OTHER STRAPPING INHERE ` DATION STRAPPING PPNG RENOVATION WORK ALLOWS. SIMPSON MTSA 18-Z W/ �(6) 8d NAILS TOP t BOTTOM a 32" O.C. �I SIMPSON LTP4-Z W/ �y //��(4) 8d NAILS TOP t (6) 8d NAILS TOP t SIMPSON LTP4-Z W/ BOTTOM a 32" D.C. FLOOR JOIST BOTTOM a 32" O.C. NAIL SHEATHING TO SILL PLATE TOP OF FOUNDATION 8d NAILS a 4" O.C. 2 - U5 REBAR cn (SHEATHING TO LAP SILL PLATE) :.; :, '• DRAWING TI TLE:x8 SILL IE (EXISTING)C0PPER TERMITE SHIELD (I) 2x8 SILLt (NEW)w/ SILL SEAL (T P (PRES SURE E TREATED) , SE E FOUNDATION ATI ON DW G. E TION FOR DESIGN/REINF0 R I CN G , .v f 5/8" x 16" A.B. a32" OC. w/ 2"x2"x3/16" WASHER. SECTION S 0 NLDESSESTEEL)V OR 12 HOLD DOWN SHEAR CONNECTION CRITICAL PATH ISOLATE WASHER FROM 12 JOB: SILL PL W/ FELT STRIP 5 3I/4 DAN HARBES Ewstmgg `� 2x6 RR„ IC cc ��� Existing RR„ 16" cc RELOCATED•, RESIDENCE' Existing : ALDRICH LANE 2x6 C.J., :16" oc MATTITUCK. NY TOWN OF SOUTHOLD SCTM# 1000-112-01-7 Existingg Window/ 2x6 RR„ 14" cc 51-8 1/ 8'-3 1/ �� Door t g 12 ARCHITECT: _ cx � 12 -' Existing Ln �� L.0 Copper 3 "FI in W g — Sill a5 H t. FREDERICK R. WEBER y 41 EAST MAPLE'ROAD Gable 14 0" 2ND FLOOR ���� Window g 2x8 RR, 16"oc GREENLAWN. NY 11740 8 Ridge Strap 2x10 Ridge - 2x8 CJ, 16"oc 2x8 R.R., 16 oc p �� Porch 52 NOYAC PATH Hurricane Existing �� - Roof P Stra all WATER MILL, NY 119'IL 2x6 C.T., I6" o Straps — 2x10 F.J., 16" oc �(2) 2x8 Rafters to Header 1,31154-5555 fwebweberarchitectayahoo.com (3) II 1/8" LVL (3) II 1/8" LVL Header Header SEAL: I I co T Existing Existing Wall New New i ao t Insul. Column II li II IST FLOOR PORCH II II I I I I I I Existing Metal Wall Flashing 5 I/4" 2x12 F.J., 16' oc u, Between Slab t Wall :. 7Spray Foam Insul. 6" F.G. Batts Existing 2x8 Silly in Box Sill W8x18 R19 •i° (8 lib"x5 I/4"x 5/16" New Pressure Treated , Copper Termite , 2x8 Sill w/ 5/8"m x ;: Shield/ Sill Seal New 10" P. Conc. 16" A.B., 32" oc Found. Wall w/ (2) 45 Bars (Top t Bot) t ! REV.: t4 Bars. 33"oc Vert. on � 20"x10" P. Conc. Ftg., p � DATE: JUNE 3. 2022 ui/ (3) 95 Bars • . . . • New SCALE: I/4" 2" Closed Cell BASEMENT JOB NO: w201512 Spray Foam Insul., R13 w/ Fireproof NEW SECTION Coating (Typ,) New 4" P. Conc. SlabDRAWING NO. ' w/ 6"x6% 10/10 WWF ' FRONT FOR (� H I I ° 1/4" = 11-011 Addition Existing OF AS SECTION AA- FREDEt"K ROBERT WEBER ARCHITECT A W W I-� <6 Pressure Treated ost, Bolt to Found., trap to Header, (Typ.) -------(3) 1 3/4"—x II 1/8" LVL------ (3) 1 3/4" x II l/8" LVL ------ (3) 1 3/4_ x II 1/8" LVL III ii• T� I ° V1 ? I I ° o a s I II > I I � :9 I �• - I..L� OD - I �I CO.I I I �, r x Cc u u iiI = X ICI _ I oxo axo x cox I I• v •I I cy cv IN 1 I a s a s I II — v v v U , III zz zz II I I I Exi5tinq Header — — — is in j—e — — Existin Header Existin Hea I el. EE it cli H N_ x X '9 — Existing (2) 2x10 Head Existing 2x10 F.J., I oc DRAWING TITLE: O O O :AND/ROOF FRAMING 000 (ADDITIONS IST) 0 0 x x a CY CV S > a' N — —— B: — — --- —_-- it X x .........I.. . —— �...... DAN HARBES K w w i I....... ........I I ' RELOCATED Existing Header ——— L____ , —————. _ — _ E —_ —J=____= I RESIDENCE w (Arched Opening) ALDRICH LANE MATTITUCK, NY OilExisting Header C� 7 TOWN OF SOIJTHOLD X, Ll _____- w �,\ SCTMS 1000-120 03-11.15 I ARCHITECT: I X Existing 2x10 F.J., 14" oc FREDERICK R. WEBER Open to 41 EAST MAPLE ROAD Above GREENLAWN. NY II140 52 NOYAC PATH Existing (2) 2x10 Header �, WATER MILL, NY 11914 ---------------------------- q = TEL 431 154-5555 �n� o IPweberarchitecteyahoo.com 'nn N X X X �9 w w r, - SEAL: Existing: Header "xd Existing :Header —_——_——_——_--_——_——_——_— _ _ _ _ _——————_— I v I•II III v I I I II New 2x8 R.R., New 2x8 R.R.,I I t I I�j T, oc III � t New 2x6 .J., 14" oc r I•I III � •' � l�' = III � I •I = , .. ...� 1�_.i FRAMING NOTES (FOR NEW WORK ONLY): I. ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR-LARCH STRUCTURAL GRADE No. 2 OR BETTER (3) II 1/8" LVL Hdr. 2. ALL SHEATHING TO BE APA RATED, EXPOSURE I, 5/8" MIN. THICKNESS OR AS NOTED. 3. ALL SUBFLOORING TO BE APA RATED STUDD-I-FLOOR, EXPOSURE I, 3/4" MIN. THICKNESS. ALL EDGES OF PLYWOOD TO BE SET ON SOLID BLOCKING. GLUE AND NAIL PLYWOOD SUBFLOOR TO FLOOR JOISTS. 4. ALL HEADERS 6'-0" AND OVER SHALL BE SUPPORTED WITH DOUBLE UPRIGHTS, T-O" AND OVER WITH TRIPLE UPRIGHTS. REV.: ALL HEADERS SHALL BE A MINIMUM OF 2-2x8 IN 4" WALL t 3-2x8 IN 6" WALL OR AS SHOWN ON DRAWINGS. 5. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AND FLOOR BEAMS AS PER N.Y.S. CODE OR AS NOTED a 8'-0" O.C. DATE: JIJNE 3. 2022 PROVIDE 2" SPACE FOR AIR CIRCULATION IN ROOFS. ,46 6. DOUBLE FRAMING AROUND OPENINGS (Skylights, Stairs, etc.) OR AS NOTED ON DRAWINGS. SCALE: 1/4" - 1'-0" 2ND / R00F FRAMING 1. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITIONS OR AS NOTED ON DRAWINGS. 8. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WITH RATED GALVANIZED METAL CONNECTORS BY "SIMPSON" OR APPROVED EQUAL, JOB NO: w202108( ADDITIONS IST ) 9. NAILING SCHEDULE SHALL BE AS PER THE N.Y.S. BUILDING CODE AS A MINIMUM. ALL 2x6 STUDS SHALL RECIEVE 5-IOD NAILS AT SILL ~AND PLATE. ALL EXTERIOR NAILS SHALL BE GALVANIZED. � DRAWING NO. 10. PLYWOOD SHEATHING TO BE NAILED WITH 8D a 4" O.C. EXTERIOR EDGES AND 0 a 12" O.C. INTERMEDIATE. ����� z II. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND STUD WITH GALVANIZED HURRICANE TYPE CONNECTORS BY "SIMPSON"OR APPROVED EQUAL. 12. ALL PRE-ENGINEERED LUMBER SHALL BE "TRUSS JOIST" TJI SERIES WOOD-I-BEAMS AND LVL PRODUCTS OR EQUAL. ALL JOISTS, GIRDERS AND HEADERS SHALL HAVE BEARING STIFFENERS INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS. WEB STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND BEARING POINTS AT A MINIMUM. A SINGLE 1 3/4" LVL RIM JOIST SHALL BE REQUIRED AT FLOOR st PERIMETERS. HANDLING, STORAGE, AND ERECTION OF COMPONENTS SHALL BE AS PER MANUFACTURERS RECOMMENDATIONS. 13. ALL MULTIPLE LVL PRODUCTS W/ STEEL PLATES TO HAVE 2 ROWS OF 1/2" DIA. GALV. MACHINE BOLTS a 24" O.C. . PROVIDE FIRESTOPPING AT ALL LEVEL PENETRATIONS, OF 51 15. BRIDGING TO BE PROVIDED FOR ALL JOISTS AND FLOOR BEAMS. SPACING NOT TO EXCEED 8'.