Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51855-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51855 Date: 04/21/2025 Permission is hereby granted to: Deborah Sutherland 42205 C R 48 Southold, NY 11971 To: install central air conditioning and gas furnace to existing single-family dwelling as applied for. Premises Located at: 42205 CR 48, Southold, NY 11971 SCTM# 59.-3-25.1 Pursuant to application dated 03/14/2025 and approved by the Building Inspector. To expire on 04/21/2027. Contractors: Required Inspections: ELECTRICAL- ROUGH, PLUMBING, ELECTRICAL- FINAL, FINAL, Fees: Single Family Dwelling- Alteration $250.00 CO-USIDENTIAL $100.00 Total S350.00 thing Inspector n .FfBt TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 htt)s://wwN .soutN! gidto iin ,gov 1%7- JP Date Received BUILDINGAPPLICATION FOR QV Fgr Office Use Only ns 9 PERMIT N0. � � Building Inspector:, st9Vilding 0ePartInef it Applications and forms must be filled out in their entirety. Incomplete -rowdy,of Southold applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date-3 01 a•5 OWNER(S)OF PROPERTY: Name:Debbie Southerland sCTM#1000-59.-3-25.1 Project Address:42205 County Rd 48 Southold NY 11971 Phone#: 631-449-1334 Email:raywires4u@gmail.com Mailing Address:42205 County Rd 48 Southold NY 11971 CONTACT PERSON: Name: Erich Gehm Mailing Address: 500 Bi-Country Rd., Suite 401, Farmingdale, NY 11735 Phone#: 631-501-6010 Email: erich.gehm@homeserveusa.com DESIGN PROFESSIONAL INFORMATION: Name:n/a Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Erich Gehm Mailing Address: 500 Bi-Country Rd., Suite 401, Farmingdale, NY 11735 Phone#:631-501-6010 Email:erich.gehm@homeserveusa.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration I @Repair ❑Demolition Estimated Cost of Project: ❑Other Replace air conditioner condenser,evaporator coil and gas furnace 15,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Dyes ❑No 1 PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Main Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes *No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.,o of the New York State Penal Law. Application Submitted By(print name): Erich Gehm glAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Erich Gehm being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)heisthe Contractor (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Lisa Kmiotek Notary Pubtic,State of New York Sworn before me this Registration No.OIKM6372315 Qualified in Suffolk County day of 11�a� , 20a Commission Expires March 1 , 20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) ..be. residing at do hereby authorize Erich Gehm to apply on m behalf to the Town of S uthol'd Building Department for approval as described herein. Y g Owner's SignaturJ Date 6aA-o?er'- r Print Owner's Rlarrie BUILDING DEPARTMENT- Electrical Inspector 01 TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 � ro err southoldtowr r ov — seared southoldtownn ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Margin Electric Electrician's Name: Mark Camarano License No.: ME-41277 Ele email:mark@marginelectric.com Elec. Phone No: 516-343-9255 I request an email copy of Certificate of Compliance Elec. Address.: 2144 Jones Ave., Wantagh, NY 11793 JOB SITE INFORMATION (All Information Required) Name: Debbie Sutherland Address: 42205 County Rd 48 Southold NY 11971 Cross Street: Tuckers Ln 01- Phone No.: 631-449-1334 01 _ 7 Bldg.Permit#: 51 515 email: raywires4u@gmail.com Tax Map District: 1000 Section: 59 Block: 3 Lot: 25.1 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Direct replacement of air conditioner condenser, evaporator coil, and gas furnace Square Footage: Circle All That Apply: Is job ready for inspection?: El YES NO D Rough In El Final Do you need a Temp Certificate? YES W] NO Issued On Temp Information: (All information required) Service Size❑1 Ph 3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT IDUE WITH APPLICATION Ruilding Degartment AlIpfication AUTHORIZATION (Where the Applicant is not the Owner) 12� Lt residing at 2916�61k� -L0 (Print property owner's name) (Mailing Address) 11-1, j )b, do hereby authorize S r I'cv\� Q�e M V. 4110/d — ........... I /cq7 / (Agent) 400\ 46 Se�-\Je, Fj\e[��IS6 O�U_3to apply on my behalf to the Southold Building Department. o ........... (Owner 's Signature) (Dafe) M Ale- Ip �n A PT (Print Owiier's Name) Lisa Krniotek Notary Public,State of New York RegiStration No. OIKM6372315 Qualified in Suffolk County Commission ExPires March 19, 20!2,6 3 X-11a� S�"� �/�'""��""may ' CERTIFIED TO:DAMES C.MOTT U� M/ A' �,YP CHARLENEMOTT HO ,may JOB NO.2005.329 .w ° TOWN OF SOUTPI'OLD MAP NO. SUFFOLK COUNTY,NEW YORK FILED: S.C.T.M.DIST.1000 SEC.059 BLK 03LOT25.1 REVISONS: REV.PROP.DWELL 6123106 25 13 0 25 50 75 160 125 150 175 260 225 LOC.FOUNDATIONW0106 SCALE:1"=50' DATE SEPTEMBER 17,2005 FINAL SURVEY 1 U2812006 Jt ADD SANITARY DIMENSIONS 1/31/200 LICENSE NO.050363 HANDS ON SURVEYING 26 SILVER BROOK DRIVE FLANDERS,NEW YORK 11901 TEL: 1).72-1854 A (631)-723-1329 MARTIN P,HAND S LOT AREA:31,016 SQ.FT.=Os712 ACRE((ROAD LINEAS WIDEND-CALC.) 34,138 SQ.FT.=0,7'84 ACRE(SEED) WATER SERVICE AND SANITARY LOCATION BY CONTRACTORS AND NOT GUARANTEED O �q 01 IV 4,0 tp , nnO "• ' PQ f Air Conditioners RA14AZ The new degree of comfort® EndeavorTm Line Classic@ Series iM Air Conditioners A O L: y } 9 is d h Z� a t � s; RA14AZ Cooling Efficiency up to: 16 SEER2/13 EER2 Nominal Sizes: 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW] _ a �L us 9001:2016 LISTED t A.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures. 'Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners,and heat pumps must be matched with appropriate coil components to;meet Energy Star.Ask your Contractor for details or visit www.energystar.gov. FORM NO.A11-337 REV.2 Table of Contents RA14AZ Table of Contents Features &Benefits...................................................................� Model Number Identification.....................................................4 General Data/Electrical Data.....................................................5 Accessories...............................................................................6 Weighted Sound Power............................................................6 UnitDimensions........................................................................7 Clearances................................................................................8 ControlWiring...........................................................................9 i Refrigerant Line Size Information......................................10-13 PerformanceData...................................................................14 LimitedWarranty.....................................................................16 P 2 1 Features and Benefits RA14AZ Features and Benefits • Lighter Footprint&Less Environmental Impact from New • Modern Cabinet Aesthetics:High curb appeal with visually 7mm Condenser Coil:provided by a decrease in refrigerant appealing design — requirements and an overall weight reduction • Curved Louver Panels:provide ultimate coil protection, • Efficient Cooling:up to 16 SEER2/13 EER2 enhance cabinet strength,and increased cabinet rigidity •' PlusOne Expanded Value Space:3in.-4in.-5 in.service • Diagnostic Service Window:with two-fastener opening- valve space-provides a minimum working area of 27-square provides access to the high and low pressure inches for easier access • External Gauge Port Access:allows easy connection • PlusOne Triple Service Access: 15 in.wide,industry leading of"low-loss"gauge ports corner service access-makes repairs easier and faster.The two fastener,removable corner allows optimal access to • OR Code:provides technical information on demand for internal unit components. Individual louver panels come out faster service calls once fastener is removed,for faster coil cleaning and easier cabinet reassembly • Fan Motor Harness:with extra-long wires allows unit top to be removed without disconnecting fan wire • System Matching Simplicity:matches to all tiers of gas furnaces 3 Model Number Identification RA14AZ Air Conditioners R A 14 A Z 24 A .J 1 N A LHP Brand Product Category SEER2 _ Region Refrigerant Capacity BTU/HR Major Series Voltage Type Controls Minor Series Option Code Rheem A-Air Conditioners 13.8/14.3 SEER2 A-All Z-R-410A 18-18,000 [5.2B kW] A-1st Design J-1 ph,208-230/60 1-Single Stage N-Non-Communicating A-1st Design LHP-W/HLPC 24-24,000 [7.03 kW] 30-30,000 18.79 kW] 36-36,600[10.55 kW] 42-42,000[12.31 kW] 48-48,000[14.07 kW] 60-60,000[17.58 kWi [ ]Designates Metric Conversions AVAILABLE MODELS DESCRIPTION RA14AZ18AJl NA EndeavorTM Line Classic®Series 1 1/2 ton 14.3 SEER2 Single-Stage[M Air Conditioner-208/230/l/60 RA14AZ18AJl NALHP EndeavorTM Line Classic®Series 1 1/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA14AZ24AJl NA Endeavor*"'Line Classic®Series 2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA14AZ24AJl NALHP EndeavorTM Line Classic®Series 2 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/l/60 RA14AZ30AJl NA EndeavorTM Line Classic®Series 21/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA14AZ30AJl NALHP EndeavorTM'Line Classic®Series 21/2 ton 14.3 SEER2 Single-Stage[M Air Conditioner w/High/Low Pressure-208/230/1/60 RA14AZ36AJ1 NA EndeavorTM'Line Classic®Series 3 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA14AZ36AJ1NALHP EndeavorTM'Line Classic®Series 3 ton 14.3 SEER2 Single-Stage jM Air Conditioner w/High/Low Pressure-208/230/1/60 RA14AZ42AJl NA EndeavorTM Line Classic®Series 31/2 ton 14.3 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA14AZ42AJl NALHP EndeavorTM Line Classic®Series 31/2 ton 14.3 SEER2 Single-Stage[M Air Conditioner w/High/Low Press ure-208/230/1/60 RA14AZ48AJl NA EndeavorTM'Line Classic®Series 4 ton 14.3 SEER2 Single-Stage jM Air Conditioner-208/230/l/60 RA14AZ48AJl NALHP EndeavorTM Line Classic®Series 4 ton 14.3 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA14AZ60AJ1 NA EndeavorTTM Line Classic®Series 5 tan 14.3 SEER2 Single-Stage[M Air Conditioner-208/230/1/60 RA14AZ60AJ1 NALHP EndeavorTM Line Classic®Series 5 ton 14.3 SEER2 Single-Stage[M Air Conditioner w/High/Low Pressure-208/230/1/60 STANDARD EQUIPMENT R-410A Refrigerant Scroll Compressor Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit 3-4-5 Expanded Valve Space Composite Basepan 2 Screw Control Box Access 15"Access to Internal Components Quick release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow Powder coated paint Rust resistant screws QR code External gauge ports Service trays 4 General Data/Electrical Data RA14AZ General Data GENERAL DATA MODEL NO. RA14AZ18 RA14AZ24 RA14AZ30 RA14AZ36 RA14AZ42 RA14AZ48• RA14AZ60 Nominal Tonnage 1.5 2.0 2.5. 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 318 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oV 94 115 120 124 149 153 203 Compressor Type Scroll Outdoor Coil Net face area-Outer Coil 10.9 13.3 14.3 16.4 19.5 19.5 32.5 Net face area-Inner Coil 10.5 12.9 13.9 15.9 18.8 18.8 - Tube.diameter-in. 0.276 0.276 0.276 0.276 0.276 0.276 0.375 Number of rows 2 2 2 2 2 2 1 Fins per inch 24 24 24 24 24 24 22 Outdoor Fan Diameter-in. 20 24 24 24 24 24 26 Number of blades 2 2 2 2 3 3 3 Motor hp 117 1/6 1/6 1/6 1/5 1/5 1/3 CFM 2156 2723 2830 2991 3655 3655 5178 RPM, 1075 825 825 825 850 850 910 watts 152 161 165 145 214 214. 271 Shipping weight-Ibs. 151 185 197 217 259 250 294 Operating weight-Ibs. 144 178 190 210 252 243 287 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)? 20 25 30 1 30 40 40 60 Minimum circuit ampacity3 14 18 19 20 24 24 40 Compressor Rated load amps 9 12 14 13 1 18 18 26 Locked rotor amps 43 60 68 83 110 102 150 Condenser Fan Motor Full load amps 0.8 0.8 0.8 0.8 1.0 1.0 2.8 Locked rotor amps 1.5 1.5 1.7 1.7 2.6 .2.6 - 'Refrigerant charge sufficient for15 ft,length of refrigerant lines.Forlonger line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. 5 Accessories/Weighted Sound Power RA14AZ Accessories MODEL NO. RA14AZ18 RA14AZ24 RA14AZ30 RA14AZ36 . RA14AZ42 RA14AZ48 RA14AZ60 Compressor crankcase heater` 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al Compressor time delay RXMD-1301 RXMD-B01 RXMD-B01 RXMD-1301 RXMD-1301 RXMD-B01 RXMD-1301 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 AXAC-A07 -RXAC-AO7 High pressure control RXAB-AO? RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC, 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC (24 VAC,50/60 Hz) Solenoid Coil I 61-AMG24V I 61-AMG24V I 61-AMG24V I 61-AMG24V I 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 2,00.D2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3tvLC 20ORD2T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG1201240V 61-AMG120/246V 61-AMG120/240V Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 `Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dBA) UNIT SIZE- STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) VOLTAGE,SERIES RATING(DBA) 125 250 500 1000 2000 4000 8000 RA14AZ18 70.7 48.2 56.0 61.9 61.0 56.5 53.5 45.7 RA14AZ24 68.5 44.6 53.6 58.7 58.0 55.5 50.5 45.7 RA14AZ30 70.8 45.1 54.5 59.8 59.0 56.8 53.8 45.9 RA14AZ36 71.6 45.4 52.6 60.2 60.8 58.7 55.9 48.4 RA14AZ42 72.5 46.6 55.3 63.9 62.1 59.4 55.2 48.2 RA14AZ48 74.0 45.4 55.7 64.2 62.9 60.8 56.7 51.2 RA14AZ60 75.8 43.4 59.8 67.2 65.5 62.7 59.2 53.1 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) i 6 Unit Dimensions • RA14AZ Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) NO. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA14AZ18 25.00 635 29.75 756 29.75 756 26.50 673 32.38 822 32.38 822 RA14AZ24 25.00 635 33.75 857 33.75 857 26.50 673 36.38 924 36.38 924 RA14AZ30 27.00 686 33.75 857 33.75 857 28.50 724 36.38 924 36.38, 924 RA14AZ36 31.00 787 33.75 857 33.75 857 32.50 826 36.38 924 36.38 924 RA14AZ42 35.00 889 33.75 857 33.75 857 36.50 927 36.38 924 36.38 924 RA14AZ48 35.00 1 889 33.75 857 33.75 857 36.50 927 36.38 924 36.38 924 RA14AZ60 51.00 1295 35.75 908 35.75 908 52.50 1334 38.38 975 38.38 975 F ALLOW 60"[1524 mm] OF CLEARANCE A R W b t 5 C A L A 6 H SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"(152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-02-00 7 03 � ID CLEARANCES m N WALL."- 1NALL, Y : 611 152.4) 24"(609.6) Service 24" 12" 12" ,,D Se9. rvice (304.8) _ (304.8) . 6" (152.4) 6" (152.4) 12" (304.8) WALL-,. 24" 24" 24" (609.6) (609.6) (609.6 Service Service Service 18" 24" 24" (457.2) (609.6) (609.6) 24" recommended 24" recommended 6"minimum 6" minimum NOTE: NUMBERS IN () = mm IMPORTANT:When installing multiple units in an alcove,roof well or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. ST-A1225-01-00 Control Wiring/Application Guidelines • RA14AZ Control Wiring FIGURE 2 'IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(WBK)AND W2(WBL)BE JUMPERED TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE TY 4) © (A) Y G R. BR -BROWN WIRE YL-YELLOW WIRE BR-BROWN WIRE X-WIRE CONNECTION R-RED WIRE YL-YELLOW WIRE WBK-WHITE WIRE WITH BLACK STRIPE DIRK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX • WBL TYPICAL CONDENSING R TYPICAL CONDENSING R UNIT UNIT X W/BK GBK YL G YL YL Y Bfl � BR BR PU Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01 -in.wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature is 125°F(51.70C). 4. For reliable operation,unit should be level in all horizontal planes. 5.Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory-supplied filter drier must be installed. 9 Refrigerant Line Size Information J 14.3 SEER2 SINGLE-STAGE AIR-CONDITIONERS � APPLY LONG LINE w ALLOWABLE ALLOWABLE GUIDELINES IF LINEAR LINE EQUIVALENT LENGTH(FEET) UNIT LIQUID LINE SUCTION LINE LENGTH EXCEEDS THOSE CZ) SIZE SIZE SIZE SHOWN BELOW (FEET) <25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 201-225 226-250 m (-)A14AZ MAXIMUM VERTICAL RISE(OUTDOOR UNIT BELOW INDOOR UNIT)./CAPACITY MULTIPLIER o 1/4° 5/8" N/A 25/1.00 50/0.99 62/0.98 43/0.98 1 24/0.97 5/0.97 5/16" 5/8" 223 25/1.00 50/0.99 75/0.98 98/0.98 93/0.97 88 L 0.97 83/0:91 7810.96 `73/0 95 681/0.94 1.5 Ton .SEE 3/8" 5/8° 148 25/1.00 50/0.99 75/0.98 100/0.98 100/0.97 100/0.97 1002l0 96 X s1 QO/0.96:: '100/0.95 _ 100/.0.94F- . _ .�,r.v. NOTE 3 1/4" 3/4- N/A 25/1.00 50/1.00 62/0.99 43/0.99 24/0.99 5/0.99 5/16" 3/4" 223 25/1.00 50/1.00 75/0.99 98/0.99 93/0.99 1 88/0.99 83/0.99 1 78/0.98 73/0.98 687 0.98 3/8. 3/4°"' 148 25/1.00 50/1.00 75/1.00 100/0.99 1 100/0.99 100/0.99 100/0.99 1 100/0.98 100/0.98 100/0.98 1/4° 5/8" N/A 25/0.99 50/0.98 21/0.97 5/16° 5/8" 213 25/0.99 50/0.98 75/0.97 _87/0.96` 1'77/0 95 ; •69/0:94, 61,1 0.93,"4" 53/•0:92 45/.0 91 3770.90 ' 3/8° 5/8" 142 25/0.99 50/0.98 75/0.97 ` 100/0:96 100 P0.95 . 100/0.94 r 98/.0:93�, "95/0:92`, 92/0:91 - 89?1090 2 Ton 1/4" 3/4° N/A 25/1.00 50/1.00 21/0.99 5/16" 3/4° 213 25/1.00 50/1.00 75/0.99 87/0.99 77/0.98 69/0.98 61/0.98 53/0:97 45/0.97 37,7 0.96 3/8" 3/4° 142 25/1.00 50/1.00 75/0.99 100/0.99 100/0.98 100/0.98 98/0.98 95/0.97 93/0.97 90%0.96 5/16" 5/8° N/A 25/0.99 50/0.98 75/0.96 70/6.64r.,59/0.93'' 487 OM 36/,0:90"` 2.5 Ton 3/8° 5/8" 117 25/0.99 50/0.98 75!0:96. 1 UO_/0694 98:/0.93 94/0 91' 90 10.90 5/16" 3/4" 175 25/1.00 50/0.99 75/0.99 70/0.98� 59/0.98 1 48/0.97 3610.96" ;9610.96 6 13/0.95 3/8" 3/4" 117 25/1.00 50/0.99 75/0.99 100/0.98 98/0.98 94/0.97 101 0,96. a . 82'%0.95� 78•/0:95 5/16° 5/8" N/A 25/0.99 50/0.97 ,:66/0 94'. °49/0.92 32/0:903/8° 5/8" 85 25/0.99 50/0.97 75/0 94' 95/0:92 - 89`/'0'.905/16" 3/4° 128 25/1.00 50/0.99 66/0.98 49/0.98 32/0.97 15/-0.9`63 Ton 3/8° 3/4" 85 25/1.00 50/0.99 75/0.98 95/0.98 89/0.97 84/.0.96, 78/Oc954. 67/0.93 61/0931/2" 3/4" 43 25/1.00 50/0.99 75/0.98 100/0.98 100/0.97 100(0:96 10040.95' 4 10010.93 100 7 0.93 _ - 5/16" 7/8" 128 25/1.00 50/1.00 66/1.00 49/0.99 32/0.99 15/0.99 3/8° 7/8" 85 25/1.00 50/1.00 75/1.00 95/0.99 89/0.99 84/0.99 78/0.98 72/0.98 67/0.98 61/0.97 1/2" 7/8" 43 25/1.00 50/1.00 75/1.00 100/0.99 100/0.99 100/0.99 100/0.98 100/0.98 100/0.98 100/0.97 3/8° 3/4° 102 25/0.99. 50/0.98 75/0.97 88/0:96 86/0 95 7210.94 -65/0.92 �-57/0.91 49-%0.90 . 3.5 Ton 1/2" 3/4" 51 25/0.99 50/0.98 75/0.97 100/0 9,6 , 100-1 0 95 100/0.94;- 100�1,0.92' 100-/o.91 ' 100/"O` 3/8. 7/8" 102 25/1.00 50/1.00 75/0.99 88/0.99 80/0.99 72/0.98 65/0.97 57/0.97 �49/0.96 42Y 0,96;: 1/2° 7/8° 51 25/1.00 50/1.00 75/0.99 100/0.99 100/0.99 100/0.98 100/0.97 100/0.97 '100•/:0.96• 10010.96 NOTES: 1) Do not exceed 200 ft linear line length. 2) 'Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. 3)-3/4"suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as Indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. Refrigerant Line Size Information (Con't.) j 14.3 SEER2 SINGLE-STAGE AIR-CONDITIONERS APPLY LINE GUIDELINES IF LINEAR LINE EQUIVALENT LENGTH(FEET) UNIT ALLOWABLE ALLOWABLE ' SIZE LIQUID LINE SUCTION LINE LENGTH EXCEEDS THOSE SIZE SIZE SHOWN BELOW (FEET) <25 26-50 1 51.75 1 76-100 1 101-125 1 126-150 1 151-175 176-200 201-225 226-250 (a)Al 4AZ MAXIMUM VERTICAL RISE(OUTDOOR UNIT BELOW INDOOR UNIT)"/CAPACITY MULTIPLIER 3/8' 3/4° 110 25/0.99 50/0.98 75/0 96 93 57/0 92 s 46'%`0.91 - 1/2' 3/4" 55 25/0.99 56/0.98 75/0 96 i_< 100/0 95 1i00%0 93 '`100 3/8° 7/8" 110 25/1.00 50/0.99 75/0.99 77/0.98 67/0.97 57/0.97 -46/,0i96 36/0.96_, 26r/'0:95 i'S/"0:95 ;4 Ton ` 1/2° 7/8° 55 25/1.00 50/0.99 75/0.99 100/0.98 100/0.97 100/0.97 100./0.98;,, 100/0.96 99/Os95 97/'0.95 3/8' 3/4° 0 25/0.99 50/0.97 . ,,751-0.94-- .61/0.02 _-46,/,0.90 1/2° 3/4° 0 25/0.99 50/0.97 75[0.94 100/'0.92 =100/0.99 - 3/8° 7/8° 0 25/1.00 50/0.99 75/0.98 61/0.97 46 10.96 #/O'_ -.18/`6.94 5 Ton 1/2' 7/8° 0 25/1.00 50/0.99 75/0.98 100/0.97 100/0 96 100/0 95_ 977'0:94 95_!0,94: ',92°/-0 93 89/0.92..' 3/8° 1-1/8" 0 25/1.01 50/ 1.01 75/1.00 61/1.00 46/0.99 32/ 0.99 18/0.99 1/2° 1-1/8° 0 25/1.01 50/1.01 75/1.00 100/1.00 100/0.99 100/0.99 97/0.99 95/0.99 92/ 0.99 89/0.98 . NOTES, 1) Do not exceed 200 ft linear.line length. 2) *Do not exceed 100 ft vertical separation If outdoor unit Is above Indoor unit. 3)-3/4"suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. i 4h �1 7 m 52 N m 7 O • - m J N Refrigerant Line Size Information i A �p 14.3 SEER2 SINGLE-STAGE AIR-CONDITIONERS APPLY LONG LINE ALLOWABLE ALLOWABLE GUIDELINES IF LINEAR LINE EQUIVALENT LENGTH(METERS) CD UNIT LIQUID LINE SUCTION LINE LENGTH EXCEEDS THOSE w SIZE SIZE SIZE SHOWN BELOW (METERS) 8 8-15 16-23 24-30 31-38 39-46 47-53 54-61 62-69 70-76 m MM[IN.] MM[IN.] (-)A74AZ MAXIMUM VERTICAL RISE(OUTDOOR UNIT BELOW INDOOR UNIT)*/CAPACITY MULTIPLIER o 6.35[1/4] 15.88[5/8] N/A 8/1.00 15/0.99 19/0.98 13/0.98 7/0.97 2/0.97 5.3 KW 7.94[5/16] 15.88[5/81 68 8/1.00 15/0.99 23/0.98 30/0.98 28/0.97 27/0.97 ,.25/0.96;'[ 24/0 96 u `22' 0,65 211'0.04 [1 SSEE] 9.53[3/8] 15.88[5/8] 45 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 30/0.97 30/.0;96 ,,;30/0 96�. =30/10 95 3610.94 NOTE 3 6.35[1/4] 19.05[3/4]" N/A -8/1.00 15/1.00 19/0.99 13/0.99 7/0.99 2/0.99 7.94[5/16] 19.05[3/4]" 68 8/1.00 15/1.00 23/0.99 30/0.99 28/0.99 27/0.99 25/0.99 24/0.98 22/0.98 21/0.98 9.53[3/8] 19.05[3/4]** 45 8/1.00 15/1.00 23/0.99 30/0.99 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 6.35[1/4] 15.88[5/8] WA 8/0.99 15/0.98 6/0.97 7.94[5/16] 15.88[5/8] 59 8/0.99 15/0.98 23/0.97 27/0:96 23/0.95, 21/"0.94,`• •1910.93 .1610.92'- : 14/0;91 . 11./0.90 7.0 KW 9.53[3/8] 15.88[5/8] 39 8/0.99 15/0.98 23/0.97 3010:96 -30/0.95 301 0.94, 30/0.93 2910:92'• 28/0:91''; _21/O.N. [2 Ton] 6.35[1/4] 19.05[3/4] N/A 8/1.00 15/1.00 6/0.99 7.94[5/16] 19.05[3/4] 59 8/1.00 15/1.00 23/0.99 27/0.99 23/0.98 21/0.98 19/0.98 16/0.97 14/0.97 ;.11,%0.96• 9.53[3/8] 19.05[3/4] 39 8/1.00 15/1.00 23/0.99 30/0.99 30/0.98 30/0.98 30/0.98 29/0.97 28/0.97 271 0.96 7.94[5/16] 15.88[5/8]. N/A 8/0.99 15/0.98 23:/096 21-10.94 18-/'0.93 15/0:91 , '11,/0.90 8.8 KW 9.53[3/8] 15.88[5/8] 36 8/0.99 15/0.98 234 6 96 30/0.94 307 0.93 29/0.91 27/0.90 [2.5 Ton] 7.94[5/16] 19.05[3/4] 53 8/1.00 15/0.99 23/0.99 21/0.98 18/0.98 15/0.97 11./0.96 8/0.96: 4 f 0.95 9.53[3/8] 19.05[3/4] 36 8/1.00 15/0.99 23/0.99 30/0.98 30/0.98 29/0.97 27/0.96 26/0.96. .. 25 i'0.95 24/0.95 7.94[5/16] 15.88[518] N/A 8/0.99 15/0.97 264 0.94_ 1'5/0.92, 10/0.90 9.53[3/8] 15.88[5/8] 26 8/0.99 15/0.97 23/0.24 29/6:92 27/ 7.94[5/16] 19.05[3/4] 39 8/1.00 15/0.99 20/0.98 15/0.98 10/0.97 5'/096 10.6 KW 9.53[3/8] 19.05[3/4] 26 8/1.00 15/0.99 23/0.98 29/0.98 27/0.97 26,/0.96 „24./0:95 22,/0 94,, `:'20 L 01.03 _y'.1910.93-: [3 Ton] 12.70[1/2] 19.05[3/4] 13 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 ' .30/0.96. °30/0 96 :30,+/0 94,y 30,70 93- 7.94[5/16] 22.23[7/8] 39 8/1.00 15/1.00 20/1.00 15/0.99 10/0.99 5/0.99 9.53[3/8] 22.23[7/8] 26 8/1.00. 15/1.00 23/1.00 29/0.99 27/0.99 26/0.99 24/6.98 22/0.98 '20/0.98 19'/0.97 12.70[1/2] 22.23[7/8] 13 8/1.00 15/1.00 23/1.00 30/0.99 30/0.99 30/0.99 30/,0.98 30/0.98 30/0.98 30/0.97 9.53[3/8] 19.05[3/4] 31 8/0.99 15/0.98 23/0.97 -27/0.96 2410.0 95 :r 2210.94 -_ 20/0:92 17/0.91`."':15%6.90 12.3 KW 12.70[1/2] 19.05[3/4] 15 8/0.99 15/0.98 23/0.97 _30/0.96 -30/0 95-, ':30/0.94 -30/0.92, 3010.91, 30%0.90 [3.5 Ton] 9.53[3/8] 22.23[7/8] 31 8/1.00 15/1.00 23/0.99 27/0.99 - 24/0.99 22/0.98 20/0.97 17/0.97 _15/0.96 -13/0.96 12.70[1/2] 22.23[7/8] 15 8/1.00 15/1.00 23/0.99 30/0.99 30/0.99-- 30/0.98 30/0.97 30/0.97 30/0.96 30/.0.96 NOTES: 1) Do not exceed 61m linear line length. 2) Do not exceed 30m vertical separation if outdoor unit is above indoor unit 3)-19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. Refrigerant Line Size Information (Con't.) 14.3 SEER2 SINGLE-STAGE AIR-CONDITIONERS ALLOWABLE ALLOWABLE APPLY LONG LINE EQUIVALENT LENGTH(METERS) LIQUID LINE SUCTION LINE GUIDELINES IF LINEAR LINE UNIT SIZE LENGTH EXCEEDS THOSE SIZE SIZE SHOWN BELOW (METERS) <25 26-50 1 51-75 76-100 1 101-125 1 126-150 1 151-175 1 176-200 1 201-225 226-250 (-)Al4AZ MAXIMUM VERTICAL RISE(OUTDOOR UNIT BELOW INDOOR UNIT)"/CAPACITY MULTIPLIER 9.53[3/8] 19.05[3/4] 34 8/0.99 15/0.98 -23/O 96 24/,0.95 2010.93'- 17(0.92 14/0.91- 12.7[1/2] 19.05[3/4] 17 .8/0.99 15/0.98 23/0.96. 30/6.96 ' 3010.93 .30!0.92` 30/0.91 - 14.1 KW 9.53[3/8] 22.23[7/8] 34 8/1.00 15/0.99 23/0.99 24/0.98 20/0.97 17/0.97 _14'/0:96-. 11/.0.96- 8/0.95. ,,5/A.95-._ [4 Ton] 12.7[1/2] 22.23[7/8] 17 8/1.00 15/0.99 23/0.99 30/0.98 30/0.97 30/0.97 30/.0.96 30/'0.98 - .-30/0.95 30/',0 95 9.53(3/8] 19.05[3/4] 0 8/0.99 15/0.97 ,.23/0 94 19fok 14./0:90' 12.7(1/2] 19.05[3/4] 0 8/0.99 15/0.97 29/,0:941 - 30/0:92 _ 30/'0.90' 9.53[3/8] 22.23[7/8] 0 8/1.00 15/0.99 23/0.98 19/0.97 14/,0.96 10/10.'95 5/'0 94 R 17.6 KW 12.7[1/2] 22.23[7/8] 0 8/1.00 15/0.99 23/0.98 30/0.97 3610.96 30/0.95 3.0/0.94J 29/D.94, 28/,0.93 27 l 0:92 [5 Ton] 9.53[3/8] 28.58[1-118] 0 8/1.01 15/1.01 23/1.00 19/1.00 14/0.99 10/ 0.99 5/0.99 12.7[1/2] 28.58[1-1/8] 0 8/1.01 15/1.01 23/1.00 30/1.00 30/0.99 30/0.99 30/0.99 29/0.99 28/ 0:99 27/0.98 NOTES: 1) .Do not exceed 61m linear line length. 2) *Do not exceed 30m vertical separation if outdoor unit is above indoor unit. 3)"19.05mm suction line should only be used for 1.5 tan systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded In light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. J � w CD m N m 7 O O1 W O 7 Performance Data RA14AZ Performance Data @ AHRI Standard Conditions- Cooling DESIGNATED TESTED COMBINATION(DTC) . OUTDOOR INDOOR TOTAL CAPACITY NET SENSIBLE NET LATENT SEER2 EER2 INDOOR UNIT COIL BTU/H[KW] BTU/H IKW] BTU/H[KW] CFM ILA] RA14AZ18AJ1 RCFZ2417STAN 17,100 [5.0] 13,100 [3.8] 4,000[1.2] 14.3 11.7 6001283.21 RA14AZ24AJ1 RCFZ2417STAN 22,800 [6.7] 17,500 [5.1] 5,300[1.6] 14.3 11.7 7.25[342.21 RA14AZ30AJ1 RGFZ3617STAN 28,600 [8.4] 21,800 [6.4] 6,800[2.b] 14.3 10 900[424.81 RA14AZ36AJ1 RGFZ3617STAN 34,200[10.01 26,200 [7.7] 8,000[2.3] 14.3 11.7 1,025[483.71 RA14AZ42AJI RCFZ4821STAN 38,500[11.31 29,500 [8.6] 9,0110J2.61 14.3 11.7 1,300[613.51 RA14AZ48AJ1 RCFZ4821STAN 45,000[13.2] 34,500[10.1] 10,500[3.1] 118 11.2 1,425[672.51 RA14AZ60AJ1 RCFZ6024STAN 56,000[16.4] 42,900[12.6] 13,100[3.8] 13.8 11.2 1,600[755.11 NOTE:This data includes DTC(Designated Test Combination)ratings and is for reference purposes only.A full listing of official ratings and system match-ups,along with downloadable certificates,can be accessed from the AHRI website:www.anddirectory.org. [ ]Designates Metric Conversions I 14 Blower Performance Data R921T Blower Performance Data AIR FLOW PERFORMANCE-92%SINGLE STAGE CONSTANT TORQUE INPUT[BTUI AIRFLOW. SPEED TAP/ CFM AIR DELIVERY CABINET CONTROL SETTINGS WIRE COLORS EXTERNAL STATIC PRESSURE INCHES WATER COLUMN WIDTH[IN] 0.1 0.2 . 0.3 0.4 0:5 0.6 0.7 0.8, 0.9 1 .Factory SetGng`Fan ; Lod k, 807= 765 717_. 557 502 448-_,' 396 w/Re "666 612 ,'" 349 .' Heat or Heat/Cool Medium Low/Yellow 965 921 874 824 771 716 659 601, 543 484 1�K _,,,` ' Coop`__ MediuMYPurple- ., ;1076'' z'1035, '-994` .`053 '910' 864 : ,913' 758 697 . -630 Cool Medium.High/Blue 1150 1108 1068 1030 991 951 908 860 806 745 Factory5etting,Cooling ,: :, . •High/Black _ 1298 1259 1220 . .1182 _1194 1106 1067. . 1028 987 945 Factory Setting Fan Low/Red 998 950 906 853 791 728 676 634 584 542 F •H6t-,bNsat1Cobl 'Mediuin Low/;Yellow A060- 1016 963 N '862 . 802 759: 766,;. 663 17' , ,616 Cool Medium/Purple 1143 1104 1060 1016 970 930 873 820 769 725 =.'Medium Hi6 Blue ;1328 ,':1293 _1258 ''1220 1'1'831- 1142 1107 •1069•+ •1016' 960 Factory.Setting Cooling High/Black 1473 1441 1 1403 1366 1331 1295 1265 1236 1200 1159 �Faatory�Setting Fan ,�.�; LawlRed �635 602'�_ •564° �524', . 482 -440 399, ' 362'`' •329 �'302 Cool Medium Low/Yellow 1080 1035 985 931 874 816 759 704 654 610 107' Heator'Heat/Cool MediuWPurple ;;_1222 ! •1183 ! 1'138 # 1090 1039.. _985 931 017824 774 Cool Medium High/Blue 1371 1330 1290 1251 1210 1169 1125 1078 1028 972 Factory Setting Cooling,', ;' High/Black--' - 1458' 1,1421 1385 =1349 1312 1274 1M'-: 1.193 1148. -1101 Factory Setting Fan Low/Red 1154 1105 1046 980 911 841 773 7% 653 608 Heat or Heat/Gool- °Medium Low/Yeilow 1450, 1405 135T_' 1307 1255 1202. 1147_ 1091 103fi' 981 21' Cool Medium/Purple 1583 1536 1490 1446 1401 1356 1308 1257 1203 1144 21° ' Cool Medlum,High/,Blue' ' 1750 1703,,i 1662 11626,; ,1591, 1556 1520.` 4479 , J432 ;1377 Factory Setting Cooling High/Black 1981 1931 1894 1865 1835 1797 1745 1671 1568 1428 '•"Faatory.S . 559; 5265. 8 734 679„ , 08Fan 1022 93tting Heat or Heat/Cool Medium Low/Yellow 1651 1611 1571 1518 1476 1434 1383 1311 1271 1208 85K 21° = =;:Cogl'; Meditim Pftrple :1,755 ' 4712 1670"`1ti26 1596. 1531,_ 1490 •1'445 1421. 1337 Cool Medium High/Blue 2042 1996 1971 . 1944 1901 1872 1849 1812 1767 1738 Factory'Setting Cooling,. `Hi,gh>Black 21t4 '2082 2049" 2009• 1,974 4940 1'903_ 1821-• ..1752" 1633 . Factory Setting Fan Low/Red 1336 1274 1200 1156 1090 1019 965 916 852 796 Heat orHeat/Cool `. Medium•Low/Yellow ; 1574=; 1521 14881 1423. ,1376 •1327 1272 '1219 1170 1114 1 Cool Medium/Purple 1683 1644 1609 T559 1521 1464 1427 1366 1313 1280 21" _ MediuHigh/81ue. 1 A 1801 , 7 73 166 1661 161113153 1400l . i 61 Factory Setting Cooling High/Black 2063 2018 1992 1943 1914 1875 1837 1807 1768 1726 "'f' Facto °Settin 'Fan Low/Red 1466 '133fi; 1268 1196r 11'25: •1078 1003 942 869; 808y rY 9 Cool Medium Low/Yellow 1561 1491 1423 1359 'i304 1227 1171 1129 1071 1018 115K } , _ _ - - - - 24° ,Heat or Heat/•Cool Medium/Pdrpie,, 1696 . 1645, 1586- 1533, .1480 1407 1370":.IM& -,1254 1220 Cool Medium High/Blue 1852 1801 1761 1701 1630 1591 1523 1466 1427 1362 .- factory Setting, High/Black-,-_., .1996" 1,951 '' 1890 1840'' 1799 .1741 1666 1612; 1602. 1534. 7 Accessories R921T Vent Termination Kits: = For High Altitudes: RXGY-EO2:Vertical/Horizontal Concentric Vent Termination Kit NOTE:For Canadian installations only,an optional derate(manifold 2 Pipe(US Only) gas pressure reduction)method may be used to adjust the RXGY-E02A:Vertical/Horizontal Concentric Vent Termination Kit furnace for altitude.See Installation Instructions for moreinformation.This optional method may NOT be used for U.S. 2�� Pi US a &Canadian p y p ( ) installations.See installation instructions as appropriate orifice RXGY E03:Vertical/Horizontal Concentric Vent Termination Kit change is required. 3" Pipe(US Only) RXGY-E03A:Vertical/Horizontal Concentric Vent Termination Kit L.P.CONVERSION KIT:RXGJ-FP38 3" Pipe(US&Canadian) CONDENSATE PUMP KIT:PROSTOCK&1 PCB151 TUL RXGY GO2:Direct Vent Furnace Side Wall Vent 2"or 3"(US Only) DOWNFLOW/HORIZONTAL CONVERSION KIT:RXGY-CK RXGY D05:Combustion Air Drain Kit 2" DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE 'CONVERSION KIT:RXGY ZK RXGY-DO6:Combustion Air Drain Kit 3" COMBUSTIBLE FLOOR BASE:RXGC-B17 NEUTRALIZER KIT:RXGY-A01 RXGC-1321 (Replacement Cartridge 54-22120-01) RXGC=624 EXTERNAL BOTTOM FILTER(UPFLOW/HORIZONTAL)RACK: RXGF-CB [ ]Designates Metric Conversions EXTERNAL SIDE(UPFLOW)FILTER RACK:RXGF-CD EXTERNAL(DOWNFLOW)FILTER RACK:RXGF-CC FILTER RACK FILTER SIZES"INCHES[mm] RXGF-CB RXGF-CD RXGF-CC MODEL (UPFLOW/ (UPFLOW) (DOWNFLOW) HORIZONTAL) R921T(-)040 153/4 x 25 153/4 x 25 14 x 20 [400 x 635] [400 x 635] l356 x 508] R921T(-)060 153/4 x 25 153/4 x 25 14 x 20 [400 x 6351 [400 x 635] [356 x 508] R921T(-)070 153/4 x 25 153/4 x 25 14 x 20 1400 x 635] (400 x 6351 [356 x 508] R921T(-)070 191/4 x 25 153/4 x 25 12 x 20 (wide) [489 x 635] [400 x 635] [305 x 508] R921T(-)085 191/4 x 25 153/4 x 25 14 x 20 [489 x 635] [400 x 6351 [356 x 508] R921T(-)100 191/4 x 25 153/4 x 25 14 x 20 [489 x 635] [400 x 635] [356 x 5081 R921 T(-)115 223/4 x 25 153/4 x 25 14 x 20 [578 x 635] [400 x 635] 1356 x 508] Indoor Coil Casings MODEL NUMBER RXBC-D17A1 RXBC-D21A1 RXBC-D21B1 RXBC-D24A1 8 b A 4 i { P;R G D. U :GIUII D E s .."�•� rr. _� � i.3 � y `F4,by `y � _ r ,c llr• I - -�5 ase se Premier_Evaporator Coi"I [iF x4 ' . 0 �� ST Advanced stributor iProduct Premier Evaporator Coil f The Premier Upgrade forSy- stem pg Any ADP premier evaporator coils match perfectly with your system, providing an upgrade over standard matched coils. ADP coils are thoroughly tested to ensure optimal`quality and deliver reliable ratings. They are uniquely designed to save customers time on installation, while ensuring a leak-free system. ADP premier evaporator coils are the perfect solution for your application. r � r + ;Li kv y .r Built-In Plenum Flanges Built-in plenum flanges with rounded corners allow for fast and safe installation SKU Optimization Upflow, Downflow,'Multi-position configurations; AL & CU coil options support local markets Leak Free Rubber Plugs Suction and liquid lines do not require cutting for installation Non-Captive Front Panels Provides fast and easy coil access without the need to cut refrigerant lines 1% or Less Cabinet Air Leakage Allows to add tape to seamsle installation without the Improved Air Quality Lower Height Microbes can double every 20 minutes ADP provides space saving opportunities on an untreated surface! and a perfect fit with your furnace! rh Standard 25.0" plastic pan 5 Ton with visible j.•.. y. ,. �-, mold 5,� •z 4 Ton 20.0" Plastic pan with MICROBfall�� Microban® 17.5" antimicrobial additive 3 Ton ----------- 16.5" ,----------- 15.0 Mold is part of our environment and, there are no practical ways to completely eliminate mold spores. 12.5" The best defense against mold in a home is to prevent it from taking hold through moisture control and the use of mold resistant building materials. THE ADP ADVANTAGE PROTECTION ADP is the exclusive provider of coils featuring antimicrobial product protection by Microban®, a recognized consumer brand. QUALITY ADP proprietary testingitechnology ensures leak-free performance at the higher operating pressures of R-410A systems. SERVICE ADP coils are made for seamless installation and easy access. ENERGY SAVINGS Many models are available to achieve higher SEER levels for ENERGY STAR compliance, utility rebates,and federal tax credits. WARRANTY ADP coils come with a no hassle 5-year warranty and feature an available 10-year limited warranty.Simply register online at www.ADPwarranty.com. , Premier Evaporator Coil Made in the USA NOMENCLATURE from US and Imported parts .x ,`' �� Cak�metDIV � i Cabinetx Metering Nominal Cabinet Cabmen Product CQ or� Slab No ®euice �MBTLLUH De��th �dth UpPr :HexCode a" Access Portt R a s 'Notch H:Embossed/ E&A:CU 1:Piston(R-410A) 18 A:Unc. Cased A:Unc. 00:Unc. 00:RH Uncased AP:TXV Access uncased slab 9:Non-bleed 24 C:20.5" 140:14.0" B:0.75" 12:12.5" 01:RH Cased Port A:Armstrong G:AL slab HP-A/C TXV 142:14.25" (cased) 04:LH Uncased 30 D:21.0" 16:16.5" D:Ducane/ (R-410A) 36 E:21.5 145:14.5" 18:18.5" 05:LH Cased " Aire-Flo 175:17.5" ./ (u to 31.5") 20:RH Cased G:ICP 42 210:21.0" p multi-pos. 48 245:24.5" J:Goodman/ 22:LH Cased Amana 60 255:25.5" multi-pos. N:Nordyne Uncased P:Carrier/ 130:13.0" Bryant/ Payne 140:14.0" R 155:15.5" :Rheem/ Ruud 170:17.0" T:Trane/ 200:20.0" American 205:20.5" ii: Standard 235:23.5" Y.York/ 251:25.12" Luxaire/ Coleman *See Spec Guide for additional nomenclature details. ADDITIONAL FEATURES �1 7., '�7 ti^ TXV with all threaded connections Patented HydroTECTM low water Painted cabinet options for furnace saves time in the field retention drain pan color coordination No brazing required Dual drain connections on each side for ease of installation Proudly • • distributed • • • 2175 West Park Place Boulevard COus Stone Mountain, Georgia 30087 www.adpnow.com ' ©byAdvance,d Distributor Products.AU rights r,es, nred': Ws rPSPnrp the right to i,hFi rh2n0Ps m specjfratjon SL-HAC 21 _ at any,time;without.noticb�and withou't:Uabil_i to' •urehasers or owners of 'reviousl sold a ui:merit{Y P' p Y 9'-P February2021 Gas Furnaces br R921T The new degree of comfort® EndeavorT"" Line Classic® Series Gas Furnaces i ,N1 '.��• i 1 t , 1 R921 T 92% A.F.U.E.t Heating Stages: Single Stage Motor Type: Constant Torque Input Rates: 40 to 115 kBTU [11 .7 to 33.7 kW] Configuration Options: 4-Way Multi-Position QOAUFIED ONLY IN r. O &US CA,DC,DE FL AN, �P.ri RL KY,LA,MD,MS,NV.NM, 9001:2015 LISTED nc oK saTN.ncvA t A.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures. FORM NO.G11-672 REV.2 Table of Contents R927T Table of Contents Features&Benefits..................................................................3 Model Number Identification....................................................4 Physical Data and Specifications.............................................5 Dimensional Data.....................................................................6 Blower Performance Data........................................................7 Accessories..........................................................................8-9 Limited Warranty....................................................................12 z r i 9 ' Features and Benefits R921T Features and Benefits • PlusOne®Energy Efficiency:ENERGY STAR®(South) • PlusOne®Water Management System:Rheem-exclusive certified,featuring 92%AFUE across all model sizes patented block drain sensor that automatically shuts off the furnace when the drain is blocked and alerts'the contractor • PlusOne®Diagnostics:Industry-first,7-Segment LED for via.diagnostic code quick and easy service • PlusOne®Ignition System:Proven Direct Spark Ignition(DSI) for reliability and longevity 3 Model Number Identification R921T Gas Furnaces R 92 1 T 040 3 A 17 M4 s N A S Brand Furnace Stages Motor Type Heating Input AC Max. Major Width Position NOx Controls Minor Option Code Efficiency of Heating Capacity Series Series R-Rheem 92-92%AFUE 1-Single-Stage T-Constant 040- 40,000111.7 kW] 3-3 ton drive A-1st Design 17-17.5°Width M4-Multi-S-Standard N-Non-Communicating A-1st Series S-Standard Grade Torque 060- 60,000 117.6 kW] 5-5 ton drive series 21-21°Width 4 Way 070- 70,000 121.5 kW] 24-24.5°Width 085- 85,000[24.9 kW] 100-100,000[29.3 kW] 115-115.000[33.7 kW] [ ]Designates Metric Conversions AVAILABLE MODELS STANDARD EQUIPMENT R921T0403A17M4SNAS 100%Safety Lock Out R921T0603A17M4SNAS 29-4c Stainless Steel Secondary Heat Exchanger Design R921T0703A17M4SNAS 7 Segment Led R921T0705A21M4SNAS Aluminized Steel Primary Heat Exchanger Design R921T0855A21M4SNAS Blocked Drain Sensor R921T1005A21 M4SNAS Blower Compartment Door Safety Switch R921T1155A24M4SNAS Completely Assembled and Wired Cool Fan Off Delay Direct Drive Motor Electronic Air Cleaner Connections Field Selectable Heat Fan Off Delay Flame Sense Current Diagnostics Fully Insulated Heat Exchanger Cabinet Humidifier Connections Induced Draft Motor Limit Controls Low Speed Continuous Fan Option Manual Shut-Off Valve Marked Condensate Hoses Multi-Speed Constant Torque Blower Motor One Hour Automatic Retry Power and Self-Test Diagnostics Pressure Switch Redundant Main Gas Control Single Speed Option for Heating and Cooling Applications Solid Bottom Blower Insulation Solid State Time On/Off Blower Control Transformer Twinning(Built-In)Features FURNACEWARNING THIS 1 APPROVED 1' RECOMMENDED 1' USE IN MOBILEHOMES 4 Physical Data and Specifications R921T i Physical Data and Specifications r MODEL NUMBERS R921T0403A R921T0603A R921T0703A R921T0705A R921TO855A R921T1005A R921T1155A 17M4SNAS 17M4SNAS 17M4SNAS 21M4SNAS 21M4SNAS 21M4SNAS 24M4SNAS HIGH FIRE INPUT 42,000(12.301 56,000[16.41] 70,000120.511 70,000[20.511 84,000[24.611 98,000[28.721 112,000[32.82] BTU/HR[kW] iD HEATING CAPACITY 39,900[11.69] 53,200[15.59] 66,500[19.49] 66,500[19.49] 79,800[23.39] 93,100[27.28] 106,400[31.181 BTU/HR[kW] HIGH ALTITUDE OUTPUT 35,910[10.52] 47,880[14.03] 59,850[17.54] 59,850[17.54] 71,820[21.05] 83,790[24.56] 95,760[28.061 10/a DEBATE[kW] BLOWER(D x W)[mm] 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 10 11 x 11 [279 x 178] [279 x 203] [279 x 2031 [279 x 254] [279 x 254] [279 x 254] [279 x 2791 1/2[373] 1/2[373] 1/2[373] 1 [746] 1 [746] 1 [746] 1 [746] MOTOR H.P.[W]-TYPE 5 Spd Constant 5 Spd Constant 5 Spd Constant 5 Spd Constant 5 Spd Constant 5 Spd Constant 5 Spd Constant Torque Torque Torque Torque Torque Torque Torque MIN.CIRCUIT AMPACITY 8.00 10.00 10.00 12.00 13.00 15.00 14.00 MIN.OVERLOAD 15.00 15.00 15.00 15.00 20.00 20.00 20.00 PROTECTION DEVICE MAX.OVERLOAD 15.00 15.00 15.00 20.00 20.00 20.00 20.00 PROTECTION DEVICE MOTOR FULL LOAD AMPS 6.1 6.1 6.1 12.4 12.4 12.4 12.4 MAXIMUM EXT.STATIC .9[0.224] .9[0.224] .9[0.224] .9[0.224]. .9[0.224] .9[0.224] .9[0.224] PRESSURE(IN.W.C.)[kPa] HEATING SPEED MED-LOW MED-LOW MED MED-LOW MED-LOW MED-LOW MED COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH HIGH TEMPERATURE RISE- 25-55 35-65 40-70 30-60 35-65 40-70 45-75 HIGH FIRE RANGE IN [14-31] [19-36] [22-39] [17-33] [19-36] [22-39] 125-42] DEGREES-F[°C] APPROX.SHIPPING WEIGHT 123 128 133.5 146.5 150 155 190 (LBS.)[kg] [56] [58] (61] [66] [68] [70] [86.2] AFUE O 92.00% 92.00% 92.00% 92.00% 92.00% 92.00% 92.00% NOTES: All models are 115V,60HZ,1 Phase Gas connection size for all models is 1/2"[13 mm]N.P.T. O Installation instructions for high altitude derate. O Canadian installations only. O In accordance with D.O.E.test procedures. NOTE:Standard model complies with California low NOx requirements up to 40ng/J. This furnace does not meet air district requirements of 14 ng/J NOx emissions limit,and thus is subject to a mitigation fee of up to$450. This furnace is to be installed for propane firing only in air districts requiring 14 ng/J NOx emission limits.Operating in natural gas mode is in violation of these Rules. [ ]Designates Metric Conversions 5 Dimensional Data R921T FRONT BOTTOM TOP \ A 121/32" 15/e [42 mm] —I �' [41 mm] g B OPTIONAL I OPTIONAL 5m] 51e° VENT OUTLET 1816" COMBUSTION AIR mm) INLET KNOCKOUT [16 mm] (16 mm] SUPPLY AIR CZ) 1927/32° A 247/e" [504 mml ' [631 mm] 261/4" � 24" 237/32" [667 mm] 0 [633 mm] RETURN [590 mm] W AIR 1925/3e bu [502 mm] 34" 18ea mmJ 9/32 [17 mm] 13/4° 121/32" C [45 mm] (42 mm] C7 A 2631,e"[665 mm] 253/1e"[656 mm] 295/a"[752 mm] 2571,e"[646 mm] 2811,e"[713 mm] 4 235/1e°[593 mm] IN OPTIONAL CONDENSATE OPTIONAL 11/e" 192713e[504 mm] 5/�. 22slie[567 mm] DRAIN(DOWNFLOW) CONDENSATE DRAIN [28 mmJ [16 mm] (DOWNFLOW) OPTIONAL TRAP 2231/3e LOCATION [583 mm] (HORIZONTAL) aTIONAL ' 327/e" GAS CONNECTION GAS [835 mm] TRAP LOCATION CONNECTION I (HORIZONTAL) 291F1e" 1�2313/te" OPTIONAL COMBUSTION OPTIONAL TRAP. F [738 mm] [605 mm] VENT LOCATION LOCATION 291/32" OPTIONAL CONDENSATE (HORIZONTAL) V38 mm) DRAIN(UPFLOW) 6PTIONAL I/ENT 261/e" 17+/1s' r AIR INLET [4451mml [583 mmJ [443 mm] ,`OPTIONAL LOW VOLTAGE CONDENSATE DRAIN 263/ie" (T WIRING 14" NPFLOW) 1811e" 3221/a2" 1665 mm] ELECTRICAL CONNECTION [461 mm] [829 Im PTIONAL LINE VOLTAGE m] [356 mm] LINE VOLTAGE WIRING ELECTRICAL CONNECTION (_ LOW VOLTAGE IF T I —L A I J 225/e"[575 mm] 11' 8" 2W 1684 mm] 243/1e°1614 mm] [203 mm) 1111[280 mm] (279 mm] [203 mm] 265/1a°leas mm] RIGHT SIDE LEFT SIDE Unit Dimensions Clearance to Combustibles MODEL LEFT MINIMUM CLEARANCE(IN.)[mm] FLANGE DIMENSIONS R921T SIDE RIGHT BACK TOP FRONT VENT A B C SIDE 040 0 0 0 1 [25] 2[51] 0 171/2[445] 1617/64[413] 1613/64[412] 060 0 0 0 1 [25] 2[51] 0 171/2[445] 1617/64[413] 1613/64[4.12] 070 0 0 0 1 [25] 2[51] 0 171/2[445] 1617/64[413] 1613/64[412] 070(wide) 0 0 0 1 [25] 2[51] 0 21 [533] 1949/64[502] 1945/64[500] 085 0 0 0 1 [25] 2[51] 0 21 [533] 1949/64[502] 1945/64[500] 100 0 0 0 1 [251 2[51] 0 1 21 [533] 1949/64[502] 1945/64[500] 115 0 0 1 0 1 [25] 2[51] 0 241/2[662] 2317/64(591] 2313/64[589] 'A service clearance of at least 24"is recommended in front of all furnaces [ ]Designates Metric Conversions Supply and return depicted as upflow configuration. Flange configuration will vary depending on installation orientation. 6