Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51853-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51853 Date: 04/21/2025 Permission is hereby granted to: Soundview Dreams LLC 1 Morgan Ct Manhasset, NY 11030 To: Legalize as-built standby accessory generator at existing single family dwelling as applied for. Additional certification may be required. Premises Located at: 2505 Soundview Ave, Mattituck, NY 11952 SCTM# 94.4-12.2 Pursuant to application dated 03/13/2025 and approved by the Building Inspector.. To expire on 04/21/2027. Contractors: Required Inspections: Fees: As Built Generator, $250.00 ELECTRIC -Residential $200.00 CO Accessory $1.00.00 Tptal 550.00 Building Inspector TOWN OF SOUTHOLD-BUILDING DEPARTMENT ` Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 µ Telephone (631) 765-1802 Fax(631) 765-9502 ]https: /www.soqtholdto nn . o Date Received APPLICATION FOR BUILDING PERMIT ""�4 W'd-1 1,3 2025 For Office Use Only PERMIT NO. " Building Vnspectcc.; Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: -� - 5-- OWNER(S)OF PROPERTY: Name: /Z� �V vCTM#1000- Project Address: '7t,e-iC !l r L - ail° Phone#. Em . Mailing Address: ,✓ p CONTACT PERSON: Name: f��. e Mailing Address: Phone#: _ Email: > DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: '001"91—4t Mailing Address: ��5 f� e4 4.gX-e-l( Phone#: 3!- 7� f-_ � ,a 1=m , I-f-4 o,, ows DESCRIPTION OF PROPOSED CONSTRUCTION C.c11 kwts, (a ^^ ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: gOther c $ Will the lot be re-graded? ❑Yes ®N10- Will excess fill be removed from premises Yes ❑No 1 PROPERTY INFORMATION Existing use of propertysr Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to '? �le this property? ❑YesjZBo IF YES, PROVIDE A COPY. heck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a pass A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): qTAGhorized Agent ❑Owner Signature of Applicant: ��jr!'S �.r`z !c �,� Date: .3 S' CONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 SS: Quallf led in Suffolk County COUNTY OF ) Commission Expires April Z11f.,!`s 4 Ai being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of G��...V \ ,20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Pan. d� A< vt , residing at i d S �o�� iUC 1___1 &S do hereby authorize to apply on my beh f to the Town of Southold Building Department for approval as described herein. ow es Signature Date Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector TOW TOWN OF SOUTHOLD „ 202 � ����f ��� � n Hall Annex- 54375 Main Road - PO Box 1179 � t Southold, New York 11971-0959 k M;" Telephone (631) 765-1802 - FAX (631) 765-9502 arnesh southoVdtownn . ov —seand southoddtownn . ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Au Infor tion Required) Date: Company Name: Electrician's Name: License No.: Elec. email:: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: f01 � Address Cross Street: Phone No.: 107 ,107� Bldg.Permit#: email: Tax Map District: 1000 Section: Block: '- /-Z7-t= Lot: lam. BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): A,. L square Footage; Circle All That Apply: Is job ready for inspection?: ES F� NO [:]Rough In inal Do you need a Temp Certificate?: YES [ ]AO Issued On Temp Information: (All information required) Service Size1 Ph F]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[—]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 M H Frame M Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION C .w i " p LL- o 'ro. ' mm"m i V410 m ?Z9 � I V * FRI \12 °11 SEP 2 4 2020 0 ------------ Sn In�.�utl ki 'a � \a yn t xa m LE_SEND_ DI -DRAINAGE INLET � UTILITY POLE y6�" 0+�5 \ 1$ =LIGHT POLE ark 't GMF=GONG.MONUMENT FOUND a � � 5176 P PATIO y mK APPROVED BY "BOARD OF TRUSTEES T0iOFSOUTHOLD � PRIDPOSED ESTATd.'L59tCW.iM emow lit 20ZQ a 51'F E ii �"AwaG.p.2CtlC a�"' �'Qw,I M1'Jd1NC.215E '°1S,B \ 2 siniex � �i 5.4 M2 E � rcSMRAG�C' -A d \ A \06.6Z� 1p' e00e. as i SITE DATA .°aa»mM .._............... � AREA=41,844 50.FT. w • V15 i1GA1 DAT1M =NAY.DATUM 214BB) '.,,,....... �+.� 4a� 400 OM—d-Av.—,RIvarheed,New Yar1,,11401 SURVEY FOR ' "k Lei 651.13133031651.131,0144 ddmatra5yaev9en91noering— PENNY B45105 gouq of Mattltuck,Town oP Southold Ti eo d awr Suffolk County,New York Robert O.Tmt Architect .... abw�iaq E, o,P�2e mtaraat lWdta r Di PERMIT SURVEY P Robert 5tromskl,Ar County Tax Map oi°m„1000 s°nw„94 m OI m, 122 „�.�...,..._. .wry,.... ....................._....�..,.—. Q w SURVEYOR'S GERTIFICA � MAP MO-AP PO OCT.23,2018 � e •m 1a5R&^i9"t C'E in^x To Pruaw*+r + c 2gcp w`ya, FtxaCOe",,'D'aP'R,ea+�aBi�no F'f4ta A% D a2 AxDARaaL'W6iN RECORD OF REVISIONS DATE 5 rog p.AJV VEYS AC OP"ID " ACSOVATION 4d8''PRuM.1'�& ARE �Wiilli Ti '°"'� u Scale:I°= 50' HOWARD w YOUNS,N.rs..ls.No.46B49 LAND 112011 OF I Pi Or.mono way I+ana aAIM,Sea 21,:010 Dm' owe i a\zmei\zale_o 191-bi G�Ss�sa2S 5/�53 KOHLER. Models: 20RESC(L) Multi-Fuel LPG/Natural Gas 49001 Standard Features 4 KOHLEP- • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT). o Designed for today's most sophisticated electronics. q o Electronic speed control responds quickly to varying "W VZ demand. o Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power P quality. o OnCue@ Plus Generator Management System for remote � y� � � '• ,,�,; monitoring is included with the generator. • Kohler Command PRO Engine Features o Kohler Command PRO@ OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. o Powerful,reliable air-cooled performance. , o Simple field conversion between natural gas and LPG The Kohler® Advantage fuels while maintaining emission certification. • Designed for Easy Installation • High Quality Power o Polymer base eliminates the need for a concrete Kohler home generators provide advanced voltage and mounting pad,reducing installation time and cost. frequency regulation along with ultra-low levels of o Fuel and electrical connections through the enclosure wall harmonic distortion for excellent generator power quality to eliminate the need for stub-ups through the bottom. protect your valuable electronics. o Load connection terminal block allows easy field wiring. • Extraordinary Reliability o Designed for outdoor installation only. Kohler is known for extraordinary reliability and • Certifications performance and backs that up with a 5-year or 2000-hour o Meets emission regulations for U.S. Environmental limited warranty. Protection Agency(EPA)with both natural gas and LPG. • Powerful Performance Note: CARB does not regulate emergency standby Exclusive Powerboost'' technology provides excellent generators with outputs less than 50 HP. starting power. o UL 2200/cUL listed (60 Hz model). • Corrosion-Proof Enclosure o CSA certification available(60 Hz model). The bold new Kohler design is completely corrosion proof, o GOST certified (Russia). even in harsh seaside environments,and is impact- o Accepted by the Massachusetts Board of Registration of resistant even at-341 C(-30' F). Plumbers and Gas Fitters • Fast Response • Approved for stationary standby applications in locations Kohler generators restore power to your home quickly and served by a reliable utility source. reliably. • 20RESCL models packaged with a Model RXT automatic transfer switch are available. See page 6 and the Model RXT ATS specification sheet. • Warranty o Standard 5-year/2000-hour limited warranty for on-grid (standby) applications in locations served by a reliable utility source. G4-246 (20RESC) 1/19d Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 120* 1 60 18/18 150 20/20 166 175 1 110/220 1 60 18/18 81 20/20 90 100 2 120/240* 1 60 18/18 75 20/20 83 100 2 2F7 100/200 1 50 15/15 75 16/16 80 80 2 115/230 1 50 15/15 65 16/16 69 100 2 220t 1 50 15/15 68 16/16 72 80 1 230 1 50 15/15 65 15/15 65 80 2 240t 1 50 13/13 54 13/13 54 80 1 120/208* 3 60 17/21 58 17/21 58 70 3 110/220 3 60 17/21 55 17/21 55 80 3 127/220 3 60 17/21 55 17/21 55 80 4 120/240* 3 60 17/21 51 17/21 51 60 3 2G7 220/380 3 60 17/21 32 17/21 32 40 4 277/480* 3 60 17/21 26 17/21 26 30 3 100/200 3 50 14/17 50 15/18 54 63 3 220/380$ 3 50 14/17 26 15/18 28 32 4 230/400 3 50 14/17 25 15/18 27 32 4 240/416$ 3 50 14/17 24 15/18 26 32 4 * UL listed. t 50 Hz single-phase models are factory-connected as 230 volts.Field-adjustable to 220 or 240 volts by an authorized service technician. $ 50 Hz 3-phase models are factory-connected as 230/400 volts.Field-adjustable to 220/380 or 240/416 volts by an authorized service technician. Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All three-phase units are rated at 0.8 power factor.All single-phase units are rated at 1.0 powerfactor.The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage.No overload capacity is specified at this rating.Ratings are in accordance with ISO-3046/1, BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DEBATING:ALTITUDE:Derate 4%per 305 m(1000 ft.)elevation above 153 m(500 ft.). TEMPERATURE:Derate 2%per 5.5°C (10°F)temperature increase above I VC(60°F).Availability is subjectto change without notice.The generator set manufacturer reserves the rightto change the design orspecifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator distributor for availability. G4.246 (20RESC) 1/19d Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator a Compliance with NEMA,IEEE,and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field • Self-ventilated and dripproof construction. Leads,quantity 2F7 4 a Windings are vacuum-impregnated with epoxy;varnish for dependability and long life. 2G7 12 Voltage regulator Digital • Superior voltage waveform and minimum harmonic distortion from skewed alternator construction. Insulation: NEMA MG1-1.66 Material Class H • Digital voltage regulator with±1.0%no-load tofull-load Temperature rise(60 Hz) 1300C Standby RMS regulation. Temperature rise(50 Hz) 150°C Standby a Rotating-field alternator with static exciter for excellent Bearing:quantity,type 1,Sealed load response. Coupling Direct • Total harmonic distortion (THD)from no load to full load with Amortisseur windings Full a linear load is less than 5%. Voltage regulation,no-load to full-load RMS ±1.0% One-step load acceptance 100%of Rating 0 Peak motor starting kVA: (35%dip for voltages below) 240 V,1 ph 2F7(4 lead) 41 (60 Hz) 23b V,1 ph 2F7(4 lead) 28(50 Hz) 240 or 480 V,3 ph 2G7(12 lead) 69(60 Hz) 208 or 416 V,3 ph 2G7(12 lead) 55(50 Hz) i I G4-246 (20RESC) 1/19d Application Data Engine Fuel Pipe Size Engine Specifications Minimum Gas Pipe Size Recommendation,in.NPT Manufacturer Kohler Natural Gas LPG Engine:model,type CH1000 4-Cycle Pipe Length, 281,000 340,000 Cylinder arrangement V-2 m(ft.) Btu/hr. Btu/hr. Displacement,cm3(cu.in 999(61) 8 (25) 1 3/4 Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) 15 (50) 1 1 Compression ratio 8.8:1 30 (100) 1 1/4 1 Main bearings:quantity,type 2,Parent Material 46 (150) 1 1/4 1 1/4 Rated RPM 61 (200) 1 1/4 1 1/4 60 Hz 3600 50 Hz 3000 Fuel Requirements Max.engine power at rated rpm, Fuel System kW(HP) Fuel types Natural Gas or LPG LPG,60 Hz 23.0(30.9) Fuel supply inlet 1/2 NPT LPG,50 Hz 20.0(26.8) Fuel supply pressure,kPa(in.H20): Natural gas,60 Hz 20.2(27.1) Natural gas 0.9-2.7(3.5-11) Natural gas,50 Hz 16.8(22.5) LP 1.7-2.7(7-11) Cylinder head material Aluminum Fuel Composition Limits* Nat.Gas LPG Valve material - Steel/Stellite® Methane,%by volume(minimum) 90 min. - Piston type and material Aluminum Alloy Ethane,%by volume(maximum) 4.0 max. - Propane,%by volume 1.0 max. 85 min. Crankshaft material Heat Treated,Ductile dron propene,%by volume(maximum) 0.1 max. 5.0 max. Governor:type Electronic C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,no load to full load Isochronous Sulfur,ppm mass(maximum) 25 max,. Frequency regulation,steady state t0.5% Lower heating value, Air cleaner type Dry MJ/m3(Btu/ft3),(minimum) 33.2(890) 84.2(2260) * Contact your local distributor for suitability and rating derates based Engine Electrical on fuel compositions outside these limits. Engine Electrical System Operation Requirements Ignition system Electronic, Capacitive Discharge Fuel Consumption Starter motor rated voltage(DC) 12 Fuel Fuel Consumption,m3/hr.(cfh) Battery(purchased separately): Model Type %Load 60 Hz 50 Hz Ground Negative 100 8.0 (281) 6.4, (225) Volts(DC) 12 75 6.9 (243) 5.4 (189) Battery quantity 1 Natural 50 4.6 (161) 3.9, (139) Recommended cold cranking amps: Gas 25 3.6 (127) 2.91 (103) (CCA)rating for-18°C(0°F) 500 20RESC Exercise 2.0 (71) 2.0, (71) Group size 51 100 3.9 (136) 2.91 (102) 75 3.1 (109) 2.4' (85) Exhaust LPG 50 2.3 (82) 1.8, (63) 25 1.7 (59) 1.31, (47) Exhaust System Exhaust temperature exiting the Exercise 1.0 (35) 1.0 (35) enclosure at rated kW,dry,°C(OF) 260(500) Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3)' LPG: 93 MJ/m3(2500 Btu/ft.3); Lubrication LPG conversion factors: 8.58 ft.3=1 lb. Lubricating System 0.535 m3 1 gal.=1 kg - Type Full Pressure 36.39 ft. Oil capacity(with filter),L(qt.) 1.9(2.0) Oil filter:quantity,type 1,Cartridge Oil cooler Integral G4-246 (20RESC) 1/19d RDC2 Controller • Front-access mini USB connector for SiteTech- or USB Utility connection • Integral Ethernet connector for Kohler@ OnCue°Plus d ge 24011 O o Freq: 60.0Hz O • Built-in 2.5 amp battery charger o_ao o • Remote two-wire start/stop capability for optional connection 1 ^ 0 of a Model RDT transfer switch ® "°° �" • Diagnostic messages: o Displays diagnostic messages for the engine,generator, Model RXT transfer switch,programmable interface The RDC2 controller provides integrated control for the module(PIM),and load shed kit generator set, Kohler@ Model RXT transfer switch, o Over 70 diagnostic messages can be displayed programmable interface module(PIM),and load shed kit. • Maintenance reminders The RDC2 controller's 2-line LCD screen displays status • System settings: messages and system settings that are clear and easy to read, o System voltage,frequency,and phase even in direct sunlight or low light. o Voltage adjustmento Measurement system, English or metric RDC2 Controller Features • ATS status(Model RXT ATS required): o Source availability • Membrane keypad: o ATS position (normal/utility or emergency/generator) o OFF,AUTO,and RUN pushbuttons o Source voltage and frequency o Select and arrow buttons for access to system . ATS control Model RXT ATS required): configuration and adjustment menus ( q ): • LED indicators for OFF,AUTO,and RUN modes o Source voltage and frequency settings • LED indicators for utility power and generator set source o Engine start time delay o Transfer time delays availability and ATS position (Model RXT transfer switch o Voltage calibration required) o Fixed pickup and dropout settings • LCD display:o Two lines x 16 characters per line • Programmable Interface Module(PIM)status displays: o Backlit display with adjustable contrast for excellent o Input status (active/inactive) visibility in all lighting conditions o Output status(active/inactive) • Scrolling system status display: • Load control menus: o Generator set status o Load status o Voltage and frequency o Test function o Engine temperature o Oil pressure Generator Set Sound Data o Battery voltage Model 20RESC 8 point logarithmic average sound levels are o Engine runtime hours 64 dB(A)during weekly engine exercise and 69 dB(A)during • Date and time displays full-speed generator diagnostics and normal operation. For • Smart engine cooldown senses engine temperature comparison to competitor ratings,the lowest point sound levels • Digital isochronous governor to maintain steady-state speed are 62 dB(A)and 67 dB(A)respectively.* at all loads All sound levels are measured at 7 meters with no load. • Digital voltage regulation: ±1.0%RMS no-load to full-load • Automatic start with programmed cranking cycle * Lowest of 8 points measured around the generator. Sound levels at P 9 9 Y other points around generator may vary depending on installation • Programmable exerciser can be set to start automatically on parameters. any future day and time,and run every week or every two weeks • Exercise modes: o Unloaded weekly exercise with complete system diagnostics o Unloaded full-speed exercise i o Loaded full-speed exercise(Model RXT ATS required) G4-246 (20RESC) 1/19d KOHLER® Phone 9 CO.,Kohler,Wisconsin 53044 USA Phone 20-457-4441,Fax 920-459-,1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Available Options,Continued • Battery cables Maintenance • EPA certified fuel system ❑ Maintenance kit(includes air filter,oil,oil filter,and • Corrosion-proof polymer sound enclosure spark plugs) • Critical silencer Warranty • Field-connection terminal block ❑ Optional Extended 5-Year/2000 Hour Comprehensive Limited • Fuel solenoid valve and secondary regulator Warranty • Line circuit breaker Automatic Transfer Switches and Accessories • Multi-fuel system,LPG/natural gas,field-convertible ❑ Model RDT ATS • Oil drain extension with shutoff valve ❑ Model RXT ATS • OnCues Plus Generator Management System ❑ Model RXT ATS with combined interface/load • Premium 5-year limited warranty management board Load shed kit for RXT or RDT • RDC2 generator set/ATS controller ❑ Power relay modules(use up to 4 relay modules for • Rodent-resistant construction each load management device) • Sound-deadening,flame-retardant foam per UL 94, ❑ Other Kohler®ATS class HF-1 20RESCL Model Packages Available Options ❑ 20RESCL with 100 amp RXT with 16-space load center Approvals and Listings and NEMA 1 steel enclosure for indoor installation ❑ CSA approval ❑ 20RESCL with 200 amp service entrance-rated Model RXT with combined interface/load management board Communication Accessories and corrosion-resistant NEMA3R aluminum enclosure ❑ OnCue@ Plus Wireless Generator Management System Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery Generator Set Dimensions and Weights ❑ Battery heater, 120VAC Overall Size,L x W x H: 1216 x 665 x 733 mm ❑ Battery heater,240VAG (48 x 26.2 x 29 in.) ❑ Cold weather package, 120VAC Shipping Weight: 243 kg (535 lb.) ❑ Cold weather package,240VAC g Shipping Weights: ❑ Emergency stop kit 20RESC Generator Set: 243 kg(535 lb.) ❑ PowerSync®Automatic Paralleling Module(APM) 20RESCL with 100 A RXT ATS w/LC 268 kg(591 Ibs;) (single phase only) 20RESCL with 200 A RXT SE ATS: 263 kg(580 lb.) ❑ Programmable interface module(PIM) (provides 2 digital inputs and 6 relay outputs) L Fuel System Accessories ❑ Flexible fuel line(included on Quick-ship[OSI models) ❑ Carburetor heater, 120 VAC H ❑ Carburetor heater,240 VAC Carburetor heater is recommended for reliable starting at temperatures below O'C(32'F) - ❑ Fuel regulator heater pad 120VAC W ❑ Fuel regulator heater pad 240VAC NOTE:Dimensions are provided for reference only and should not be used for planning installation.Contact your local distributor for more detailed information. Fuel regulator heater is recommended for reliable starting at temperatures below-18'C(0°F). DISTRIBUTED BY: Literature ❑ General maintenance literature kit ❑ Overhaul literature kit ❑ Production literature kit ©2015,2016,2017,2019 by Kohler Co.All rights reserved. G4-246 (20RESC) 1/19d