Loading...
HomeMy WebLinkAbout51090-Z SOUlyo`o Town of Southold * * P.O. Box 1179 0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45991 Date: 02/21/2025 THIS CERTIFIES that the building GENERATOR Location of Property: 1700 Alvahs Ln Cutchogue, NY 11935 Sec/Block/Lot: 102.4-7.2 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 07/03/2024 Pursuant to which Building Permit No. 51090 and dated: 08/21/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory generator as applied for. r The certificate is issued to: Neil Rousso , Sandra Rousso Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51090 2/20/2025 PLUMBERS CERTIFICATION: A o e Si ature ��o�S�fFa TOWN OF SOUTHOLD oy� BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE �y • �� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51090 Date: 8/21/2024 Permission is hereby granted to: Rousso, Neil 125 Oak St Tenafly, NJ 07670 To: install generator as applied for. At premises located at: 1700 Alvahs Ln SCTM # 473889 Sec/Block/Lot# 102.-4-7.2 Pursuant to application dated 7/3/2024 and approved by the Building Inspector. To expire on 2/2012026. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector pE SO!/T�,ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • 0 Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: (Veil Rousso Address: 1700 Alvahs Ln City: Cutchogue St: NY Zip: 11935 Building Permit#: 51090 Section: 102 Block: 4 Lot: 7.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Double Pole Electric License No: 3913ME SITE DETAILS Office Use Only Indoor Basement 1- Service 17- Solar F. Outdoor R" 1st Floor r7 Pool r Spa r Renovation 17 2nd Floor r Hot Tub 1-i Generator Survey ❑ Attic 1— Garage ri Battery Storage r INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: Kohler 30kW Generator w/400A Transferswitch Notes: Generator Inspector Signature: X Date: February 20, 2025 Sean Devlin Electrical Inspector sean.devlina-town.southold.ny.us 1700AIvahsGenerator i . I oF soulyo� " r`7 c v v TOW F S UTHOLD BUILDING DEPT. 631-765-1802 C d INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKIN [ .] FRAMING /STRAPPING [ ] FINAL d [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTI [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRA N� [ ] ELECTRICAL (ROUGH) > pELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL -t RE RKS: UN r-WI 13 ��lDr -� IJ- f W o400e gAAels ., I�l '7 DATE INSPECTOR ( , " k OF SOGTy�Io S71090 1-7 V v At v4A J. tl . TOWN OF SOUTHOLD BUILDING DEPT. �ourm,��'i� 631-765-1802 INSPECTION. [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ : ] -FIRE RESISTANT CONSTRUCTION —[ ] FIRE RESISTANT PENETRATION ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: uo rA N !l� -� ► n ands S o , .1'A Acy C.'rC 104( b y_ QAW�Cr Ml_j,f_)AQ, k / flof 401XA, / y JIM 047.10" .% IA -4rqA DATE INSPECTOR Ir FIELD INSPECTION REPORT DATE COMMENTS — � b FOUNDATION (1ST) — y - G _ `b C FOUNDATION (2ND) z o c ROUGH FRAMING& $-3 PLUMBING Q 1 INSULATION PER N. Y. -- y STATE ENERGY CODE C I n - -- — FINAL ADDITIONAL COMMENTS �2 0 _ z y x -- d y ... .. �o TOWN OE SOUTHOLD—BUILDING DEPARTMENT _. . H. Towri Hall:Anriex 5437:5 Main:Road P. 0 Box 1179 Southold,-NY 119:71 0959 Telephone(63.1)'765-1802' Fax(631) 765 95.02 https:%%www.southoldtownnvgov - . I�ate. ,... .Received.; APPLICATION FOR:BUILDING PERMIT :: . ::.: . C". - For Office Use Only D :. PERMIT N0. Buildinglnspector: _ JUL. 20Z4- d. Applications and f r orltl rpty,1.14Incomplete aappiications,Wlllbot be accepted Where the'Apphcant is not th`e owner,an/ y % _ :: -BUM001G DEPT.. O,wner's Autho�izat�on form Pa e 2 shall be'com leted r SOU�>£ f�I ,,..,�. ' 6..,;�rf ✓;5'/,;;�i+q���n,,,w ��,+,g,�{/ �u ,,;i4 s�r��,y�p4/'�',r.;r �NH4r///t( Fdi�'�y.f�y�F;//rarh��� .- l��Y � ? .. .. Date:M/24 . OWNERS)OF PROPERTY r Name Nell & Sandy Rousso :_. sCTM#i000-102=4-7.2 Project Address 1700Alvahs Lane Cutchogue, NY q. Phone:#:201-723.5100:: : :Email:nrprideJoY@g-mail.corn Mailing Address: :: ' ,.a; �;-r�/ /� /M J 4✓+d r; r {�r,r,r yy sr h�/ ,n/ h� a///n r rn r y H / u /i� r/ rs -�byr r'�t ✓;r .... CONTACT/APERSON Name:Nicholas Zourrias (Almas Construction :LLC).. Mailing Address: :_ .. .. . :.::..:...._ .__263 _ oute. 25A -. ading'River 'NY. 11792.::,,:.._: , . . .. : . :Phone#:631-872=2045 :. Email nick:zoumas@aim' nstruction coma. DESIGNiPROFESSIONAIlNFORMATION q Name: Mailing Address: ...:Phone:#:..:. :Email: °CONTRACTOR%I NFORMATION's ... Name:. . .... ... ..... ..... ..... Almas.Construction-LLC: .. . Mpill.ng Address:.263_Route 25A.Wading_River;.,NY 117.92 Phone#:631-872.2045 Email nick.zoumas@almasconstruction com .; ,/,r ,,r y.. DESCRlP<PION'OF�PROPOSEDFCONSTRUCTIONw a k r�rv/ $ r ur`�Y//r ✓ rl / / `a .✓,gin,. +. .-r.rr77 ❑New:Structure::❑Addition: :❑Alteration ❑Repair❑Demolition :Estimated:Cost of:Project: D Other Generator $7,500 Will the lot be:re-graded? ElYesANo Will excess fill be-removed from premises? ❑YesIgNo .. .. PROPERTY:INF.ORM ATION" .:Existing:use of property:Residential Intended use ofproperty Residential .... . Zone.or use:district in which premises is situated: Are there.any covenants and.restrictions with respect to this property? D.Yes ®No:IF YES, PROVIDE A COPY. .. , „"I/Ch@ck Boxe ToIwF nr Code:APPLICAT IQN ISr`HEREBnFY/t rMa.,.crAtt./oD rE/dtoe stiM g n:,:pro,u.fe.s,s io�/nar l isw rreG/0 s%Pt ons/i/bsl„e f/a,t r all/d'r r•a�ma ga and som,rw/,oaµy;; r/r sues,ar s„ o4v.�ded by, Chapter 236ofth he'Bi m uldIng Permit puruant to the Buildin g'Zor}e ordinance.of the Town`of Southold,Suffolk,County,New York and;o4her applicable laws,Ordinances orRegulations for the'constructlon of buildings, saddltions,alterati licable laws,'ord I ances,Liullding code, .' `housing code and reguiationi;and to admlYauthorized inspectors on}premise;and in bullding(sl:for necessary.inspgctlons False"s me tatents mad e herein are; , punishable as a ClassA misdemeanorpu,rsuanY'to,Sectlon.210 45 of the New;York•State Penal Caw. ApplicationSubmitted:By(print name): NICIIOIaS0UI71S @Authorized Agent DOwner Signature of Applicant Date:: IZ�2 L STATE OF NEW-YORK) COUNTY OF .. .. . . . being duly sworn,:tleposes and says that-(s)he is the applicant :•�. (Name of individual signing contract)above named, (S)he is the ,r .. (Contractor,Agent,Corporate Officer,etc.) of said.owner or owners,and is duly authorized,to perform.or have.performed.the,said work'and to,make and file.this application;that:all statements contained in this application are true.to:the best:of his/her.knowledge:and belief;:ancl that the:work will be performed in the manner set forth in the:application file therewith. Sworn before me th's'- -day of �Ij 20 ✓Li Notary Public .. .. .. .... ::. .. : -. .ANNIE E ESGRO:: .: PROPERTY'OWNERAUTHORIZATION. : .•NOTARYPiIBLic:STATEOFNYo K:.- SUFFOLK.COUNTY.-_.:', : _ .. (Where the a:pplicant:is.not the:o'ner) :. uc.#a1Ess07808$.: :: ..... 1 ....COMM. EXP.05/1.9/2027 . 1`d sso re§idingat. : I bQ Vg1�4thrS L . . . .. . . . .. . .. . l7 one:: o hereby authorize . t .c_ �i;r►v�a :: to apply on my behalf to.the TdWV,,of Sou d Building:Department for approval as described herein. .. Owner' 6griature. : /' Dat r Oe:: 7�z�L`t` IDvSSO --- .... JOHN A.:M;4KI Print Owner's Name Notary.Public-State of New York `�� .. No.:01 MA61 E483� Qualified in Suffolk County::: :: 2 My.Commission Exp. 04/30/202, . g�FFO(� BUILDING DEPARTMENT- Electrical Inspector C-9, TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 d ° I rogerr@southoldtownny.gov - seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (AIIInformation Required) Date: , Company Name: Double-Pole Electric, Inc. -I Name: Neil Rousso License No.: 3913-ME a ail: Alepaft dot•G Phone No:, (201)723-5100 01 req an email copy of Certificate of Compliance Address.: 1735 Alvahs Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: Neil Rousso Address: 760 Alvahs Cutchogue NY 11935 Cross Street: Phone No.: (201)723-5100 Bldg.Permit#: j I Cq0 email: Tax Map District: 1000 Section: 1 O a Block: Lot: , �ZL' BRIEF DESCRIPTION OF WORK (Plea a Print Clearly) New Construction Check All That Apply: _ Is job ready for inspection?: DYES 0 NO ❑Rough In ur Do you need a Temp Certificate?: OYES [-]NO Issued On Temp Information: (All information required) Service Size 01 Ph ❑3 Ph Size: 300 A # Meters One Old Meter# 09840401 B ❑New Service ❑✓ Service Reconnect 0 Underground ❑Overhead # Underground Laterals ❑✓ 1 ❑2 OH Frame❑Pole Work done on Service? ❑✓ Y ❑N Additional Information: - -- - PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.)dsx SURVEY OF LOT I PROPOSED MINOR S UBDI VISION OF MICHAEL KALOSKI PLAT FILE No. 11612 FILED MARCH 22, 2008 SITUATE CUTCHOGUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000- 102-04-7.2 SCALE 1 "=30' �Fo APRIL 26, 2016 MAY 17, 2016 ADD ADDITIONAL NOTES MARCH 3, 2020 UPDATE SURVEY Q �' F 1Cy df JUNE 9, 2021 ADD PROPOSED HOUSE JUNE 5, 2022 ADD TOPOGRAPHY Gs�c �r JUNE 22, 2022 REVISE PROPOSED HOUSE p OCTOBER 31, 2022 FOUNDATION LOCATION JUNE 24, 2024 FINAL SURVEY �y �99 AREA = 88,329 sq. ft. 0a 9 ,c>01P I 2.027 ac. O.?> ?s 100, CERTIFIED TO: NEIL A. ROUSSO SANDRA ROUSSO FIDELITY NATIONAL TITLE INSURANCE COMPANY ors s fj �0� �0 � o A� L� Tf 0 ' lee 6 .eo� •�s� 0 04b R Cr IN °e. ¢� %y y `\ 4° CJ o'%A �v y� i 00, DRAIN-1" �y*Cbo �\ @�,o�G •3 �. �� MCP '" � �i 1� ST�,Q �s• °i0° \ �QG G ��,�{�\� • � �, '(V�� CP a \ /,��y , 0 DRAIN WELL & SEPTIC SYSTEM TIE MEASUREMENTS g a Go�Qd� ryy GSF a3� o� �t �P� S'o HOUSE HOUSE °Aq, �ry CORNER QA CORNER sb qo ,� qC wog yy SEPTIC TANK , o F a" 4 DRAIN--,, '0opcy + �� OUTLET COVER 34 42 a : a a STEPPING $ :k kd w '��' LEACHING POOL , STONE WAG COVER 1 65 61 151, ti�o\ 2.0' 71' 2.0' �w—�� LEACHING POOL , o N AIR UNIT COVER COVER 2 51 57 0J, w° .k". w w LEACHING POOL COVER 3 61' 74' '�•• 2.0' b 35.3' rn a \ �o �"'p`,• \ WELL 298' 306' `S v rn aM1;• �<I�[ \S*" ".l,`q, 4 a a v ' a 'a a ?0 Sls �.9 19 'moo �10 Y UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TILE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI- TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE. THE EXISTENCE OF RIGHT OF WAYS AND/OR EASEMENTS OF RECORD, IF ANY, NOT SHOWN ARE NOT GUARANTEED. PREPARED IN ACCORDANCE WITH THE MINIMUM Nathan Taft Corwin III STANDARDS',FOR�TTTLE SURVEYS AS ESTABLISHED BY T}1E L't.p.Sr'JWTHEP--NEWVYORKJSTATEADOPTED LAND FOIE RUC( bSE� Land Surveyor �tITLE,ASSOCnIATION,•` `�,, Successor To: Stanley J. Isaksen, Jr. L.S.• ' " ' Joseph A. Ingegno L.S. y >r Title Surveys — Subdivisions — Site Plans — Construction Layout �. 'ZA •• OJF ftkE: '�< PHONE (631)727-2090 Fax (631)727-1727 s.. `? ' •F OFFICES LOCATED AT MAILING ADDRESS ` i — 1586 Main Road P.O. Box 16 Jamesport, New York 11947 Jamesport, New York 11947 v' N.Y.S. Lic. No. 50467 E—Mail: NCorwin30aol.com Ko b APP 0 ED AS NOTED DA - B.P.# FEE 0 BY NOTIFY BUILDING DEPARTMENT AT 631 765.1802 SAM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF ELECTRICAL, NEW YORK STATE&TOWN CODES INSPECTION REQUIRED AS REQUIRED AND CONDITIONS OF $00OLDTOWN ZBA S000 TOWN PLANNING BOARD TOWN TRUSTEES N,YS EC OLD HPC HD OCCUPANCY OR USE IS UNLAWFUL WITHOUT CE;RTIFICAT ,- OF OCGUPA'NCY KOHLER. Model: 30 R C LA Multi-Fuel Natural Gas/LPG 09001 Standard Features KOHLER. a Kohler Co.provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. a The generator set and its components are prototype-tested, factory-built,and production-tested. .. a The generator set accepts rated load in one step. �L a A standard five-year or 2000 hour limited warranty covers all -- = systems and components. a Quick-ship (QS) models with selected features are available. See your Kohler distributor for details. a Meets 291 kph (181 mph)wind load rating. a GFCI service outlet installed on the junction box. a RDC2 Controller o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT transfer switch). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying household demand. The Kohler® Advantage o Digital voltage regulation protects your valuable a High Quality Power electronics from harmonic distortion and unstable power Kohler home generators provide advanced voltage and quality. frequency regulation along with ultra-low levels of o Two-line,backlit LCD screen is easy to read in all lighting harmonic distortion for excellent generator power quality to conditions, including direct sunlight and low light. protect your valuable electronics. a Engine Features o Powerful and reliable 2.2 L turbocharged liquid-cooled e Extraordinary Reliability engine Kohler is known for extraordinary reliability and o Electronic engine management system. performance and backs that up with a premium five-year or o Simple field conversion between natural gas and LPG 2000 hour limited warranty. fuels while maintaining emission certification. a Aluminum Enclosure a Innovative Cooling System Attractive aluminum enclosure allows installation as close o Electronically controlled fan speeds minimize generator as 18 inches from your home or small business. set sound signature. a Certifications e Quiet Operation o The 60 Hz generator set engine is certified by the Kohler home generators provide quiet,neighborhood- Environmental Protection Agency(EPA)to conform to the friendly performance. New Source Performance Standard (NSPS)for stationary spark-ignited emissions. o cUL/UL listing, CSA certification standard are available (60 Hz only). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. o Meets NFPA 37 requirements for 18 in.offset for installation. e Approved for stationary standby applications in locations Generator Set Ratings served by a reliable utility source. Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 4E5.6 120/240 1 60 30/30 125 30/30 125 120/240 1 60 30/30 125 30/30 125 120/208 3 60 30/38 106 30/38 106 4D8.3 127/220 3 60 30/38 100 30/38 100 120/240 3 60 30/38 92 30/38 92 277/480 3 60 30/38 46 30/38 46 * 50 Hz options available.Contact your Customer Service representative. RATINGS:All three-phase units are rated at 0.8 power factor.All single-phase units are rated at 1.0 power factor.Due to manufacturing variations,the ratings tolerance is±5%. Standby Ratings Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads with an average load factor of 80%for the duration of a power outage.No overload capacity is specified for this rating.Ratings are in accordance with ISO-3046/1,EIS 5514,AS 2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:Aftitude:Derate 1.3%per 100 m(328 t)elevation above 200 m(656 t).Temperature:Derate 3.0%per 10°C(1 VIP)temperature above 25°C(77°F).Availability Is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Contact your local Kohler generator distributor for availability. G4-304 (30RCLA) 6121 Alternator Specifications Specifications Alternator • NEMA MG1, IEEE, and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Exciter type Brushless,Wound-Field . Sustained short-circuit current of up to 300%of the rated Leads:quantity,type current for up to 10 seconds. 4E5.6 4,120/240 4138.3 12,Reconnectable • Sustained short-circuit current enabling downstream circuit Voltage regulator Solid State,Volts/Hz breakers to trip without collapsing the alternator field. Insulation: • Self-ventilated and drip-proof construction. Material Class H Temperature rise 130°C,Standby • Windings are vacuum-impregnated with epoxy varnish for Bearing:quantity,type 1,Sealed dependability and long life. Coupling Flexible Disc Amortisseur windings Full • Superior voltage waveform from a two-thirds pitch stator and Voltage regulation,no-load to full-load ±1.0%Maximum skewed rotor. Unbalanced load capability 100%of Rated Standby • Total harmonic distortion (THD)from no load to full load with Current a linear load is less than 5%. One-step load acceptance' 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V 4E5.6(4 lead) 44 (60 Hz) 480 V,400 V 4138.3(12 lead) 120 (60 Hz) 88(50 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type Residential Powertrain Exhaust temperature at rated kW,dry KG2204T,2.2 L,4-Cycle exhaust, 'C(°F) 633(1171) Turbocharged Maximum allowable back pressure, Cylinder arrangement In-line 4 kPa(in.Hg) 7.5(2.2) Displacement,L(cu.in.) 2.2(134.25) Bore and stroke,mm(in.) 91 x 86(3.5 x 3.4) Fuel Compression ratio 10.5:1 Fuel System Piston speed,m/min. (ft./min.) 310(1016) 258(847) Main bearings:quantity,type 5,plain alloy steel Fuel type Natural Gas or LPG Rated rpm 1800 1500 Fuel supply line inlet 1 in.NPT Max.power at rated rpm,kW(HP) Natural gas fuel supply pressure,kPa LPG 47.8(64.1) NA (in.H2O) 1.2-2.7(5-11) Natural Gas 47.6(63.9) NA LPG vapor withdrawal fuel supply Cylinder head material Cast Iron pressure,kPa(in.H2O) 1.2-2.7(5-11) Piston type and material High Silicon Aluminum Fuel Composition Limits* Nat.Gas LP Gas Crankshaft material Nodular Iron Methane,%by volume 90 min. — Valve(exhaust)material Forged Steel Ethane,%by volume 4.0 max. — Governor type Electronic Propane,%by volume 1.0 max. 85 min. Frequency regulation,no-load to Propene,%by volume 0.1 max. 5.0 max. full-load Isochronous C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,steady state .1.0% Sulfur,ppm mass 25 max. Frequency Fixed Lower heating value, Air cleaner type Dry MJ/m3(Btu/ft3%min. 33.2(890) 84.2(2260) Engine Electrical * Fuels with other compositions may be acceptable.If your fuel is outside the listed specifications,contact your local distributor for Engine Electrical System further analysis and advice. Ignition system Electronic Battery charging alternator: Lubrication Ground(negative/positive) Negative Lubricating System Volts(DC) 14 Type Full Pressure Ampere rating 90 Oil pan capacity,L(qt.)§ 4.2(4.4) Starter motor rated voltage(DC) 12 Oil added during oil change(on average), Battery,recommended rating for-18°C(0°F): L(qt.)§ 3.3(3.5) Qty.,cold cranking amps(CCA) One,630 Oil filter:quantity,type§ 1,Cartridge Battery voltage(DC) 12 Oil cooler Remote Battery group size 24 § Kohler recommends the use of Kohler Genuine oil and filters. G4-304 (30RCLA) 6/21 ' Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Ambient temperature, °C(°F) 45(113) Engine jacket water capacity,L(gal.) 2.65(0.7) Radiator system capacity,including a: " O O Freq: 60.0 Hz ■ engine,L(gal.) 13.2(3.5) o , Water pump type Centrifugal oao o 99)3 O Fan diameter,mm(in.) qty.3 @ 406(16) r Fan power requirements(powered by ® �+ engine battery charging alternator) 12VDC,18 amps each Operation Requirements ° Air Requirements 60 Hz 50 Hz The RDC2 controller provides integrated control for the Radiator-cooled cooling air, generator set, Kohler®Model RXT transfer switch, m3/min.(scfm)t 51 (1800) 51 (1800) programmable interface module (PIM), and load management. Combustion air,m3/min.(cfm) 1.6(57) 1.3(45) Air over engine,m3/min. (cfm) 25(900) 25(soo) The RDC2 controller's 2-line LCD screen displays status # Air density=1.20 in. (0.075 Ibm/fi3) messages and system settings that are clear and easy to read, even in direct sunlight or low light. Fuel Consumption* Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz RDC2 Controller Features 100% 12.0 (424) 10.0 (353) • Membrane keypad 50% 7.6 (268) 6.3 (222) o OFF,AUTO, and RUN push buttons 50/0 7.6 (268) 6.3 (222) 25% 5.5 (196) 4.5 (159) o Select and arrow buttons for access to system Exercise 3.4 (121) 2.8 (99) configuration and adjustment menus LP Gas,m3/hr.(cfh)at load 60 Hz 50 Hz • LED indicators for OFF,AUTO,and RUN modes 100% 4.7 (166) 3.9 (138) • LED indicators for utility power and generator set source 75% 3.7 (132) 3.0 (105) availability and ATS position (Model RXT transfer switch 50% 2.8 (100) 2.3 (81) required) 25% 1.9 (69) 1.6 (56) • LCD screen Exercise 1.2 (41) 1.0 (35) o Two lines x 16 characters per line * Nominal Fuel Rating: Natural gas,37 MJ/3m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m (2500 Btu/ft3) visibility in all lighting conditions LP vapor conversion factors: 8.58 ft.3=1 lb. • Scrolling system status display 0.535 m3=1 kg. o Generator set status 36.39 ft.3=1 gal. o Voltage and frequency o Engine temperature Sound Enclosure Features o Oil pressure • Sound-attenuating enclosure uses acoustic insulation that o Battery voltage meets UL 94 HF1 flammability classification and repels o Engine runtime hours moisture absorption. • Date and time displays • Internally mounted critical silencer. • Smart engine cooldown senses engine temperature • Skid-mounted,aluminum construction with two removable • Digital isochronous governor to maintain steady-state speed access panels. at all loads • Fade-,scratch-,and corrosion-resistant Kohler@ cashmere • Digital voltage regulation: -+1.0% RMS no-load to full-load powder-baked finish. • Automatic start with programmed cranking cycle Sound Data • Programmable exerciser can be set to start automatically on any future day and time,and to run every week or every two Model 30RCLA 8 point logarithmic average sound levels are weeks 53 dB(A) during weekly engine exercise and 61 dB(A) during a Exercise modes full-speed generator diagnostics and normal operation. For o Unloaded exercise with complete system diagnostics comparison to competitor ratings,the lowest point sound levels o Unloaded full-speed exercise are 52 dB(A)and 59 dB(A) respectively.* o Loaded full-speed exercise(Model RXT ATS required) All sound levels are measured at 7 meters with no load. • Front-access mini USB connector for SiteTech- connection * Lowest of 8 points measured around the generator.Sound levels at other points • Integral Ethernet connector for Kohler OnCue�Plus around generator may vary depending on installation parameters. • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-304 (30RCLA) 6/21 KOHLER CO.,Kohler,Wisconsin 53044 USA Phone 920-457-4441,Fax 920-459-1646 KOHLER, For the nearest sales and service outlet In the US and Canada,phone 1-800-544-2444. KOHLERPower.com Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Starting Aids§ o Displays diagnostic messages for the engine,generator, ❑ Block Heater,120 V,1 Ph Model RXT transfer switch, programmable interface ❑ Block Heater,240 V,1 Ph module(PIM),and load management device ❑ oil Pan Heater,120 V,1 Ph o Over 70 diagnostic messages can be displayed ❑ Oil Pan Heater,240 V,1 Ph • Maintenance reminders § One block heater or oil pan heater is recommended for ambient • System settings temperatures below 0°C(32°F). At temperatures below-18°C(0°F), o System voltage,frequency,and phase installation of both heaters is recommended. o Voltage adjustment Automatic Transfer Switches and Accessories o Measurement system, English or metric ❑ Model RDT Automatic Transfer Switch • ATS status (Model RXT ATS required) ❑ Model RXT Automatic Transfer Switch o Source availability ❑ Model RXT Automatic Transfer Switch with Combined o ATS position (normal/utility or emergency/generator) Interface/Load Management Board o Source voltage and frequency ❑ Load Shed Kit for RDT or RXT • ATS control (Model PXT ATS required) ❑ Power Relay Modules(use up to 4 relay modules for each o Source voltage and frequency settings load management device) o Engine start time delay Maintenance o Transfer time delays ❑ Maintenance kit(includes air filter,oil,oil filter,and spark plugs) o Fixed pickup and dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable interface module(PIM) status displays Literature o Input status (active/inactive) ❑ General Maintenance Literature Kit o Output status (active/inactive) ❑ Overhaul Literature Kit • Load control menus ❑ Production Literature Kit o Load status Warranty o Test function ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty Generator Set Standard Features ❑ Extended 10-Year/2000 Hour Comprehensive Limited Warranty • Aluminum sound enclosure with enclosed silencer • Battery rack and cables Dimensions and Weights • cUL/US listed,CSA certified Overall Size,L x W x H,mm(in.): 1880 x 836 x 1169 • Electronic, isochronous governor (74 x 32.9 x 46.0) • Flexible fuel line Shipping Weight,wet,kg(lb.): 599(1320) • Gas fuel system (includes fuel mixer, electronic secondary Weight includes generator set with engine fluids, sound enclosure, gas regulator,two gas solenoid valves,and flexible fuel line silencer,and packaging. between the engine and the skid-mounted fuel system components) • GFCI service outlet, 120/240 V for customer connection • Integral vibration isolation • Line circuit breaker H • NEC prime mover shutdown switch • Oil drain extension • OnCue® Plus Generator Management System • Operation and installation literature �'--- W—� L • RDC2 controller with built-in battery charger NOTE:This drawing is provided for reference only and should not be • Standard five-year or 2000 hour limited warranty used for planning installation.Contact your local distributor for more detailed information. Available Options DISTRIBUTED BY: Controller Accessories ❑ Lockable Emergency Stop(lockout/tagout) ❑ Programmable Interface Module(PIM) (provides 2 digital inputs and 6 relay outputs) Electrical System ❑ Battery ❑ Battery Heater ❑ OnCue®Plus Wireless Radio Kt ©2021 Kohler Co.All rights reserved. G4�304 (30RCLA) 6/21 2184 .. [86.0] 602 23. 980 38.6 ONCRETE PAD OPTIONAL CUSTOMER INSTALLED DIATOR FILL ^- --- ----- --- — LOCKABLE ESTOP � . . ._-�\ 152 REF. [6.0] TYP ALL SIDES ENGINE AND ALTERNATOR • • V I �? AIR INLET Y . M F E • • LM C coo • ' ® c— II I ` ——— — S[44.31 — —— GFCI OUTLET(REQUIRES UTILITY POWER INPUT)N rn421 100 ONDUIT STUB-UP FOR a°� [16.6] [3.9] LOW VOLTAGE CONTOL PRIME MOVER LOCKOUT SWITCH 808[31.8] ONDUIT STUB-UP FOR GENERATOR LOAD LEADS AND UTILITY POWER (BOTTOM ENTRY) EXHAUST OUTLET AN FUSES 836 32.9 731 28.8 943 37.1 DOOR OPENING R FILTER CONTROLLER /—oF,'LL ///—OILTER DIPSTICK REMOVE THIS SHOWN W/DOOR REMOVED PANEL TO • • • ACCESS COOLANT • • DRAIN imp- LOAD CIRCUIT O zw BREAKER z O __ �_ __� • O o —MEM __—_=o= O O00 v ch 1 • Z CV J COOLANT LU N co O � • == �� • C, DRAIN co D. co rn LO O • ` p • • • •• • • • "' B C • • •. .. • CONNECTION BATTERY LOCATION X 016[0.6] 281 OIL DRAIN ACCESS PANEL (BATTERY NOT INCLUDED) MOUNTING HOLES [11.1] 17 59 �\—FUEL 11 0.4 809 31.9 15 INLET r 1880 [74.01 FUEL INLET 1"NPT 1128 f44.41 450 17.7 980 38.6 100 [3.9] SNOTE: at DIMENSIo IN SPECIFIED:ts DO NOT SCALE. DIMENSIONS IN[]ARE ENGLISH STANDARD EQUIVALENTS GENERAL TOLERANCES: THIS ASSEMBLY OR PART MUST X i*do.25 SURFACE FINISH COMPLY WITH PEP-RML-001. O ON COMPOSITE DWGS,SEE PART NO.FOR REVISION LEVEL X *1.5 REFERENCE CAD MODEL FOR REV SATE � CHANGE ANGLES*0*w 7 MAX �rn NUMBER INDICATES PART NUMBERS AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. N u DRAWING REVISION THIRD ANGLE PROJECTION • A 23JUL2021 CT213532 B-2 FUEL INLET I &2ADDED RVM �B KOHLER. 25 B 29SEP2022 CT221726 SEE SHEET 2 AAS C 02NOV2022 CT223403 B-2 "FUEL INLET 2 1"NPT"REMOVED MAJOR o= o KOHLER,wISCONSIN 53044 [1.0] "FUEL INLET 1"NPT"WAS"FUEL INLET 1 1" CRITICAL® ° SCALE:0.050 SHEETSRE:B SHEET 1 OF 2 CHARACTE IFTICS COMPLY WITH OPTIONAL ESTOP KIT LOCATION NPT" B-3 1517 59. WAS 1512 59.5• 5 80022 TITLE: -1 A-5 "40 L" OVED D-3 - DRAWN RVM DATE: DIMENSION PRINT, 30RCLA _ BY 30RCLA/38RCLC 38RCLC AnDED-SEF SHEET 2 NCD Ry APPRovED TAS 22JAN2021 DWG NO.: ADV-9759 O 7 C C A 7 7 OCCUPIED STRUCTURE OCCUPIED STRUCTURE OCCUPIED STRUCTURE OCCUPIED STRUCTURE SEE NOTE 7 SEE NOTE 4 SEE NOTE 4 SERVICE —— • I � SIDE DOOR SET SET `U SEE NOTE 7 — O z SERVICE SIDE DOOR - w - w SEE NOTE 8 w I _ SEE NOTE 7 SEE NOTE 8. I SET SET z w SEE NOTE 7 SEE NOTE B _I SEE NOTE 8 SERVICE SIDE SERVICE SIDE— DOOR DOOR INSTALLATION GUIDELINES 1)EXHAUST IS AIMED AWAY FROM OR PARALLEL TO THE STRUCTURE. 2)EXHAUST IS NOT DIRECTED AT PLAY AREAS,PATIOS OR OTHER AREAS WHERE PEOPLE CONGREGATE. 3)THE NEAREST WINDOW,VENT,DOOR OR SIMILAR STRUCTURE OPENING IS AT LEAST 5 FEET FROM THE EXHAUST END OF THE GENERATOR. 4)GENERATOR SET MUST BE INSTALLED A MINIMUM OF 18 INCHES FROM STRUCTURE PER NFPA 37,HOWEVER,ACTUAL DISTANCE MAY DIFFER BASED ON STATE AND LOCAL CODES. 5)WINDOWS&DOORS ON ADJACENT WALLS ARE CLOSED. 6)FURNACE AND OTHER SIMILAR INTAKES ARE AT LEAST 10 FEET FROM EXHAUST END OF GENERATOR. UNLESS OTHERMSESPECIFIED- ALL DIMENSIONS IN MILLIMETERS DO NOT SCALE. GENERALTOLERANCES: THIS ASSEMBLY OR PART MUST 7)4"THICK CONCRETE PAD EXTENDING 6-BEYOND GENSET ON ALL SIDES. x is�.5 SURFACE FINISH COMPLY WITH PEP-RML-001. ®8 NO PLANTS,SHRUBS OR OTHER COMBUSTIBLES ALLOWED IN ON COMPOSITE DWGS,SEE PART NO.FOR REVISION LEVEL x :1.5 REFERENCE CAD MODEL FOR REV DATE CHANGE ❑INDICATES PART NUMBERS AFFECTED BY LATEST BY ANGLES s0°30' MAX UNSPECIFIED DIMENSIONS. CLEARANCE AREA.(MINIMUM 4 FT.FROM EXHAUST END). NUMBER DRAWING REVISION THIRD ANGLE PROJECTION 9)SENSITIVE PLANTS,PATIO FURNITURE,ETC.ARE AT LEAST 8 FEET FROM - 22JAN2021 CT209473 NEW DRAWING RVM � . � KOHLER _ ^ EXHAUST END OF SET. A 23JUL2021 CT213532 SEE SHEET 1 RVM MAJOR o= o KOHLER,WISCONSIN s 10)REFER TO OWNERS MANUAL FOR OTHER INSTALLATION CONSTRAINTS. B 29SEP2022 CT221726 A- NOTE 8:4FT WAS 8FT '�`S CRITICAL®= o C 02NOV2022 CT223403 A-8 NOTE 11 ADDED:SEE SHEET 1 NCD cHARACTE I TI C SCALE:0.050 SHEET SIZE:B SHEET 2 OF 2 11)RECOMMENDED SKID ANCHOR-112"HILTI KWIK BOLT TZ CARBON STEEL WEDGE ANCHOR WITH STANDARD WASHER. VS-e' 29MPLY WITH TITLE: DRAWN RVM DATE: DIMENSION PRINT, 30RCLA BY 30RCLA/38RCLC 38RCLC APPROVED TAS 22JAN2021 DWG NO.: ADV-9759 0 7 e c A '] '�