Loading...
HomeMy WebLinkAbout51852-Z TOWN OF SOUTHOLD ° BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51852 Date: 04/21/2025 Permission is hereby granted to: 500 Broadwaters LLC 138-32 227th St Laurelton, NY 11413 To: install generator as applied for. Generator must have 10'minimum setbacks from all lot lines. Premises Located at: 500 Broadwaters Rd, Cutchogue, NY 11935 SCTM# 104.-10-5 Pursuant to application dated 03/14/2025 and approved by the Building Inspector. To expire on 04/21/2027. Contractors: Required Inspections: Fees: GENERATOR $125.00 ELECTRIC -Residential $100.00 CO-RESIDENTIAL $100.00 Total S325.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 httDS://www.soi�tt�ho�ldtownaygov Date Received APPLICATIONI Ek1mwEIVE For Office Use Only �j MAR 1 4 2025 PERMIT NO, f� Building Inspector:, Applications and forms must be filled out their entirety.Incomplete Building Department applications will not be accepted. Where the Applicant is not the owner,an Town of Southold Owner's Authorization form(Page 2)shall be completed. Date:2/7/2025 OWNER(S)OF PROPERTY: Name:Terry-Ann Burrell ISCTM#1000- tOY » , Project Address:500 Broadwater Rd Cutchogue NY 11935 Phone#: _� 3- �-� Email:terryanndavis@icould.com Mailing Address: 6C)C3 `OT-OCk3t^3C;�eJZ 62(� a 11:1-65, CONTACT PERSON: Name:Jesse Gaffga Mailing Address:3350 Grand Ave MattituCk, NY 11952 Phone#:631-375-2737 Email: Jgaffga@jtechss.com DESIGN PROFESSIONAL INFORMATION Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:J-TeCh Mailing Address:3350 Grand Ave Mattituck, NY 11952 Phone#:631-298-4238 Email:jgaffga@jtechss.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ROther32KW Generac Generator $20000.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property:S(n le family Intended use of property:Sin le family 9 Y 9 Y Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to th is Dyes ®No IF YES PROVIDE A COPY. property? 8 Check ox After Reading. The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(pr t name):Jesse Gaffga eAuthorized Agent ❑Owner Signature of Applicant: Date: 64-5 STATE OF NEW YORK) SS: COUNTY OF Jesse Gaffga being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this -61 day of j 202O—AC � ary PSYA.PERKINS otary Public,State of New York No.01 PE6130636 OWNERPROPERTY AUTHORIZATION Qualified in Suffolk Cotln Commission Expires July 18, (Where the applicant is not the owner) I, I erg - /kN j �7v'rt t�� residing at 500 Broadwater Rd ue,Cutcho NY 11935 9 do hereby authorize Jesse Gaffga to apply on my behalf to the Town of Southold Building Department for approval as described herein. er's Signature Date ti IVYI/ ' Print Owner's Name 2 f BUILDING DEPARTMENT-Electrical Inspector � ell TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Olt Southold, New York 11971-0959 lip Telephone (631) 765-1802- FAX (631) 765-9502 iarnesh southoldto^ nn ov sea nd southoldtownn Y.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: G &S Electric Electrician's Name: Rob Guarreillo License No.: 31568-ME Elec. email: Jgaffga@jtechss.com Elec. Phone No: 631-375-2737 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 250 Budd Ponds, Southold, NY 11971 JOB SITE INFORMATION (All Information Required) Name: Terry-Ann Burrell Address: 500 Broadwater Rd Cutchogue, NY 11935 Cross Street: Wunneweta Rd Phone No.: 631-375-2737 Bldg-Permit#: email:Jgaffga@jtechss.com Tax Map District: 1000 Section: 104 Block: 10 Lot: 5 BRIEF DESCRIPTION OF WORD, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install 32KW Generac Generator Square Foota e: Circle All That Apply: Is job ready for inspection?: YES R NO ❑Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size Ell Ph[]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Under round Laterals 1 2 H Frame Pole Work done on Service? Y nN Additional Information: PAYMENT DUE WITH APPLICATION S.C.T.M. NO. DISTRICT: 1000 SECTION:104 BLOCK: 10 LOT(S):5 BROADIPATETIERUNE COVE _— S am'46*E�.. - 0 TM MOM xlrxnuL IIAItv1/ WUMMW AS DaJWATMgr Lls aw olm mwa POT NIAB.'MO,..I"I mrE We. ZONE 7) i LOr 184 �i *29�x Z LOT 166 ISO LOT 183 LOT 6.9 6.D M,»M LA`r 16.4' t 20.1' SANITARY LOCATION La A PdJ&N7" w CNN fma ap. o sane LPT N ' o 0 w o O1 z IIW m 1 WAY& e ORPROY " 14.7' Ali fly Zo UPDATE 11-20-24 REVISED SANITARY LOCATION 07-20-24 REVISED 05-31-24 V1 FIML SURVEY 06-07-24 ION Ab"FOUNDATION LOC.01-08-24 REVISED 05-30-23 FIELD INSPECT/UPDATED 03-22-23 7HE IWA7£R SUPPLY„ W= DRYIIELLS AND LOCA770NS SH0RI1^'ARE FROM P LD OBSERVATIONS FEMA MAP#36103CO164H AND OR Q#A OBTANNED FRIOM 07NMI AREA: 32,105 S.F. or 0.74 ACRES ELEV+ATTOV DATUM NAVD88 UNAUTHORIZED ALTERA770N OR ADD1710V TO THIS SURVEY IS A WOLA77ON OF SEC77ON 7209 OF THE NEW YORK STATE EDUCARON LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED 70 BE A VAUD TRUE COPY. GUARANTEES INDICATED HEREON SMALL RUN ONLY TO THE PERSON FOR NHOM THE SURVEYS PREPARED AND DN HIS BEHALF 70 THE 7771E COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TU770N L157ED HEREON, AND TO THE ASSIGNEES OF 7HE LENDING INS7I7U770N, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHONN HEREON FROM THE PROPERTY LINES 70 THE STRUCTURES ARE FOR A SPECIRC PURPOSE AND USE 7HEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR 70 GUIDE THE ERE077ON OF FENCES ADD17IONAL STRUCTURES OR AND 07HER IMPROVEMENTS EASEMENTS '.. AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY SURVEY OF, LOT 184 CERTIFIED T0:rsl TERRY-ANN BURRELL MARILAND LLC; MAP of AMENDED MAP A OF NASSAU POINT ' NATIONAL ASSOCIATION; FlLED:AUG 16, 1922 No. 156 MORGAN STANIEY PRIVATE BANK, ��� FIRST'�ERICAN TITLE INSURANCE COMPANY SITUATED AT:CUTCHOUGE �'� �•,, TOWN UTHOLD SUFFOLKOCOUNTY, NEW YORK INN i 1 AF7 NNE Bmdoox 169 gneboaueyNewand Design 'PUN o PHONE(661)296-1668 FAX(631)NO-15M RLE I221-199 scALE:1"-40' DATE: OCT. 15, 2021 a N.Y.S P.75"C. Na s mdntdetos the reoma■of 1eba:e J.a®ae.v i Y,meta Y.woTonac .� + S5 ■ /64 G__E N E RAC® 0 51 `SZ Protector° Series G ■ Protector@ Series Standby Generators Liquid-Cooled Gaseous Engine STANDARD FEATURES STANDBY POWER RATING Model XG03245-32 kW,60 Hz Emergency Standby Power Generator • Power Zone®410 Controller,NFPA 110 System Control Capable Model XG04045-40 kW,60 Hz Emergency Standby Power Generator • Padlockable Control Panel Cover with UV Protection Model XG04845-48 kW,60 Hz Emergency Standby Power Generator • Cellular Connectivity for Mobile Link and Fleets • Quiet Operation • Corrosion Resistant Aluminum Enclosure,Electro-Galvanized Baseframe Components,and Stainless Steel Exhaust System • 5 Year/2,000 Hour Limited Warranty • High Motor-Starting&Surge Capacity • ±1%Digital Voltage Regulation ; . • <5%Total Harmonic Distortion Power Quality 4( " • Fuel Efficiency } r i • Controller-Selectable Fuel Type-Propane or Natural Gas i 1 • 1-Phase or Configurable 3-Phase Voltage Output Models • Single-Side Regular Maintenance Access • EPA Emissions Certified G • CA&MA Emissions Compliant 40&48 kW Models A \ • UL 2200 Listed NFR l • 145 mph(233 km/h)Wind Speed Rating2 \ ; 1 Cellular service for the US,Canada,and other supported countries using the Generac Generator Connectivity Accessory,Cellular(GGCAC) 2-Requires correctly prepared concrete pad and anchoring system. OPTIONAL FIELD-INSTALLABLE FEATURES Available as field-installable kits Product may vary from above image depending on model. • 3-Phase Voltage Configuration Cartridge(VCC) • 3-Phase Circuit Breakers(1-Phase Generators Include the Circuit Breaker) • Generator Ready-Status Indicator • Push-Button Emergency Stop• NFPA 110 System Control&Remote Annunciation ® E1V QUIE -Mobile Link us - • Cold Weather Operation Heaters ! • Level 2 Sound Reduction • Extreme High Wind Resistance2 • Provisions for Rooftop and Elevated Mounting • Baseframe Block-off • Engine Fluid Containment EPA Emissions Certified • Seismic Anchoring CA&MA Emissions Compliant 40&48 kW Models FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION.This GENERAC'S success in"IMPROVING POWER BY DESIGN."But it doesn't stop state-of-the-art power maximizing regulation system is standard on all Genemc there.Total commitment to component testing,reliability testing,environmental models. It provides optimized FAST RESPONSE to changing load conditions testing, destruction and life testing, plus testing to applicable CSA, NEMA, and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque- EGSA,and other standards,allows you to choose GENERAC POWER SYSTEMS matching the surge loads to the engine.Digital voltage regulation at±1%, with the confidence that these systems will provide superior performance. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive service O MOBILE LINK®CONNECTIVITY:Standard cellular connectivity included with network provides parts and service know-how for the entire unit, from the every XG generator,Mobile Link allows users to monitor generator status from engine to the smallest electronic component. anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts.Users O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous can connect an account to an authorized service dealer for fast,friendly,and with GENERAC POWER SYSTEMS. One reason for this confidence is the proactive service. With Mobile Link, users are taken care of before the next GENERAC product line is offered with its own transfer systems and controls for power outage. total system compatibility. O TRUE POWERTM ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5%Total Harmonic Distortion for utility quality power.This allows confident operation of sensitive electronic equipment and micro-chip based appliances,such as variable speed HVAC systems. a GENERAC® GENERATOR SPECIFICATIONS GENERATOR OUTPUT PROPANE XG03245 XG04045 XG04845 Voltage Power(kM Current(A) Power(kW) Current(A) Power(k" Current(A) 120/240 V1—Phase 32 133 40 167 48 200 208/120 V 3—Phase 32 111 40 139 48 167 240/120 V 3—Phase 32 96 40 120 48 144 480/277 V 3—Phase 32 48 40 60 48 72 NATURAL GAS XG03245 XG04045 XG04845 Voltage Power(M) Current(A) Power(kM Current(A) Power(kM Current(A) 26/240 V 1-Phase 32 133 40 167 48 200 208/120 V 3-Phase 32 111 40 139 48 167 240/120 V 3-Phase 32 96 40 120 1 48 1 144 4801277 V 3-Phase 32 48 40 60 48 72 Emergency Standby Power(ESP)Rating:Standby ratings apply to installations served by a reliable utility source.The ESP rating is applicable to varying loads for the duration of a power outage.The average power output over 24 hours shall not exceed 70%of the ESP rating. ALTERNATOR SYSTEM XGO3245 XG04045 XG04845 1 Phase 120/240 V Only 1 120/240 V Only 120/240 V Only Voltage Output 208/120 V;Configurable for 240/ 208/120 V;Configurable for 240/120 208/120 V;Configurable for 240/ 3-Phase 120 or 480/277 V with Optional VCC or 480/277 V with Optional VCC 120 or 480/277 V with Optional VCC 1-Phase 150 200 200 Circuit Breaker(CB) Size(A) Not Included;Optional,Field- Not Included;Optional,Field- Not Included;Optional,Field- 3-Phase Installable Kit Installable Kit Installable Kit Alternator Type Synchronous Rotor Insulation Class F Stator Insulation Class H Telephone Interference Factor(TIF) <50 Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct Total Harmonic Distortion <5% VOLTAGE REGULATION Type Digital Sensing All Phases Regulation ±1% • GENERAC® GENERATOR SPECIFICATIONS 0 SURGE CAPACITY Surge Amps at<0.4 XG03 XG04045 XG04845 Power Factor 15%Voltage Dip(A) 30%Voltage Dip(A) 15%Voltage Dip(A) 30%Voltage Dip(A) 15%Voltage Dip(A) 30%Voltage Dip(A) 120/240 V 1-Phase 107 204 117 267 — — • 208/120 V 3-Phase 111 167 139 215 — — 240/120 V 3-Phase 91 140 114 150 — — 480/277 V 3-Phase 55 87 63 102 — — ENGINE SYSTEM XG03245 XG04045 XG04845 Make Generac .Model 4.5 L,Inline 4-Cylinder,Naturally Aspirated Compression Ratio 9.9:1 Lifter Type Hydraulic Oil Pump Type Gear Oil Filter Type Full Flow Spin-on Cartridge Crackcase Capacity(qt(L)) 12(11) Temperature Derate 1.7%per 10 OF above 77 OF(1.5%per 5°C above 25°C) Altitude Derate 3%per 1,000 ft above 600 it(1%per 100 m above 183 m) Exercise Speed(rpm) 1,200 Operating Speed(rpm) 1,800 Exhaust Flow at Rated Output(CFM(0/min)) 187(8.3) 235(6.7) 280(7.9) GOVERNOR Type Electronic Frequency Regulation Isochronous COOLING SYSTEM XG03245 XG04045 XG04845 Coolant 50/50(50%Ethylene Glycol) Coolant System Capacity(US gal(L)) 2.9(11) Water Pump Type Belt Driven Fan Type Belt Driven Electric Fan Quantity 1 3 Maximum Ambient Air Temperature(OF(°C)) 122(50)