Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51837-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51837 Date: 04/17/2025 Permission is hereby granted to: Steven Stathoudakis 235 80th St Brooklyn, NY 11209 To: install roof-mounted solar panels to existing single-family dwelling as applied for, Premises Located at: 280 The Short Ln, East Marion, NY 11939 SCTM#30.-2-9 Pursuant to application dated 03/10/2025 and approved by the Building Inspector. To expire on 04/17/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total S32S.00 Building Inspector TOWN OF SOU'I HOLD —BUILDING DEPARTMENT Town full Annex 54375 Main Road P. ®. Box 1179 Southold, NCI 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 Lm. Date Received f P P I ICA riO IRBUILDING' I P F hl 11",I y � For Office Use Only 6 T". 1 0 �� "� PERMIT IVO. Building Inspector,,-- � 7 � , Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an ��"�cl�nc� l lel� rfrtnea�t Owner's Authorization form(Page 2)shall be completed. o'�"" of Southold Date: OWNER(S)OF PROPERTY- Name: Nw �+ u sCTIVI# 1ooC1- v 3 o v —o Z ov • � �C7�' .Ov o Project Address: $u cS 22 Phone#: ®Lf I Email; pe �✓7U Cc Mailing Address: a,g L) Tht, 0Y4 LPL �K_. CA44 MA-0 b CONTACT PERSON- Name: L..o rlrA l n C1 �a Mailing Address: -7 410 S o A/Il J1 vY-.i �-��1 ' � d �� �J� Phone#: (P3 Q 3 9 2 �-7 0 4 1 Email. pe. 1 1+5 DESIGN PROFESSIONAL INFORMATION.- Name: Mailing Address: Phone#: % EmaiB: CONTRACTOR INFORMATiONs Name: e l C,to e-/'l+ e y)t L l.-C, Mailing Address: Phone#: ."� `f Email: urn DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Strucctureture ❑Additi Cher r 9 on ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Will the lot be re-graded? ❑YesANo Will excess fill be removed from premises? ❑Yes o 1 PROPERTY INFORMATION Existing use of property: S Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes^'11�6-0 IF YES, PROVIDE A COPY. he; Box AfterReading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by aptr of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name);Lorraine Di Penta @Authorized Agent El Owner Signature ofApplican &UAA—AX 64 Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk Lorraine DiPenta ,being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Zday of 20 2 5 Nod ublic AUTHORIZATIONPROPERTY OWNER (Where the applicant is not the owner) I, &e) tt 0 10J<"S residing at C29 V a159ZSh04 E&S4 ( e rraa ns., a-n'yn N) y ,«a 3�j do hereby authorize C 4- , to apply on my behalf h To p So old Buildi Department for approval as described herein. Owner's Signature LOUIS J ROMEO. Date L t, Notary Public,State of New York 'I No.01 R06314813 Print Owner's Name Qualified in Suffolk County Commission Expires November.17,20 2 µ f BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rr shams ut of towrin . ov, - seard vrl APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: l -cane i (-- Ylk, L4 Electrician's Name: i innI License No.: . ,L; cl-d16 Elec. email: Elec. Phone No: �'s a-�'�ct.. -299 CAI request an email co of Certificate of Co copy m (lance p Elec. Address.: `J �,t"d o S L�_neL q V � "# ''J, !I 5 - JOB SITE INFORMATION (All Information Required) Name: d " Address: A Q p _r Cross Street: yyNA_�n Phone No.: x4ty Bldg.Permit email: Perm a C.� 00.,_�S s lc Tax Map District: 1000 Section. Block: Lot: (BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): =n�5,$ 0_a�, -P I %A-$ � f_0 C 1� rl'3 fir' a,r1-J y� �J�ds f' P"vl j<S ,ro `l ,$1 5 k-W 3< inv-#_r4-v--. 3 tS - (VIOA-U-IC3 Square Footage: Circle All That Apply: Is job ready for inspection?: YES N NO Rough In Final Do you need a Temp Certificate?: YE�Z NO Issued On Temp Information: (All information required) Service Size Ell PhD 3 Ph Size: A # Meters Old Meter# El New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground Overhead # Underground Laterals 1 2 M H Frame M Pole Work done on Service? MY N Additional Information: PAYMENT DUE WITH APPLICATION iii� CERTIFICATE OF LIABILITY INSURANCE GATE(MM1D0/YYVY11 THIS 7;15/2024 CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(Sh AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. SU ROGATION IS jWAIVED,subject t athe terms a diiiLconditi n s If at the police certain policies DrnaIvNre ,INSUREt3 provisions or beendorsed, y q Ire an endorsement. A statement on PRooUL;r:Rthis Certificate does not confer rights to the certificate holder in lieu of such rsdorssemen s'�. CON ROBERT S, FEDE INSURANCE AGENCY 'NAME;Or 23 GREEN STREET, SUITE 102 PIONS W •3 A, ~ ®" _ _.A C .m. HUNTINGTON, NY 117 ADDR„•�Ess. .-•--.' 43 E-MAIL t ROBERTS. FEDE INSURANCE ._..__ NSMJRER S AFRORDdNG COVERAGE NAIC INS ADMIRAL INSURANCE COMPAINSUREDINSGIR�'.RA: ...-`TT 24 Element Energy LLC i INSURER B; I A U DBA ELEMENT ENERGY SYSTEMS tlNsRER o �R 7470 SOUND AVENUE MATTITUCK, NY 11952 ""- NN,iI9RR E: COVERAGES nNsiIRERF: REVISION fVUMBER - Y141v THd S A TC C RTTY THaaT rHE'PCUCIESS OF ICIsLP,,A NUMBER: l aTE( IDS . CERTIFICATE BER: ��IN I�, �.E r TED VOT I) I TA(")DPNG ANY REQUIREMENT TERMS C'R CCLCIAJ N E BEEN Apl CS N RACT THE INSURED NAMED Az�GVE FCP THE POLICY PERIOD LERTIF)CATE MAY BE IS Eb CR I)A^tl PER rA@N„ 'TI(R INSURANCE AFFORDED BY THE PCLdCVES D Cr SED t dRREdOR OTHER EN SIT)4 RESPEC ALL WHICH TERMS, LT6ACLUSICNS ANC C N CITdd,nNR OF SUCH P<JLpCrd55. L9Md'T5 SHOWN MAY HA�r^E.SEEN REDUCEDBY PAID DLAIMS, COMMERCIAL GENERALNCE1v _ (LIABILITY URA POLRCY NI9MRER CY EP' "MM C+R�7L;Y�DIYYtlP EACH OCCURRENCE IT.SStl . A CLAIMS-MADE � Y OCCUR X j X CA00005380701 7/14/2024 7/14/2025 LIMIT.$ 1,000, 00 ( PR MISarxarrwna . 30 IMA389203C MED EXP(Any one perspr„ 4$ 5000 7/19/2024- - - I d 7/19/2025I PERSONAL&ADV INJURY {$ 10tl'„001 ,0. 3EN'L AGGREGATE LIMIT APPLIES PER: 5 POLICY�'�iECT L LOC I G 4 'n ENEPM F3 I"GA.i'w $ 200'0'',0 I,D"~fl(-E,R'_ P ( u PRODUCTS-COMPIOP AGG� I*5�ca S 7— AUTOMOBILE LIABILITY d u $ C NGBIIw 'C."z0fi«I,.,sLE LIMI ANYAUTC U Ea _adent � $ AUTOSCWNEP ONLY _. SCHEDULED BCDILY INJURY(Perperscn) $ � AUTOS ._�,,._... HIRED I , NON-OWNED BODILY INJURY(Per accident) $ AUTOS ONLY -j AUTOS ONLY P I PROPERTY', AM,AGE. $ UMBRELLA LIAR I Per a�aca entl CCCUR 0 EXCESS LIAB p EACH CCCURRENCE y$ pp I CLAIMS-MADE I DE'- I RETENTION, AGGREGATE d$ WORKERS COMPENSATION $ ❑ 124494445 ANY PRt.PLOY R LIABILrry E.L. C„H" AND EMPLOYERS' f3 cFFICERIMEMSEA EXC�uoe Flu ve 7/13/2024 7/13/2025 s TUTE R It,es„describe NH) X N N/A EACH ACCIDENT (rNandalr� In NH 1.000 000 DSCRIPTION OF q P„FtA p OV4 a detlu E,.L DISEASE-EA EMPLOYE S NY State DSL EL DISEASE_PCLICYLimrr $- DeLss75z7 1/01/2024 12/31/2025 Statutory DESCRIPTION CERTIFICATECRION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) HOLDER IS ADDITIONAL INSURED- CERTIFICATE I101 C1ER CANCELLATION, Town of Southold EUTHUK1ZF13 OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road TION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold, NY 11971 E WITH THE POLICY PROASION , ESENTATIVE F j „CORD 25(2016103) The ACORD name and to o are r� `3 1'988-2015 ACORD CORPORATION. All rights reserved. g _gistered marks of ACORD NEWworkers'Com ensation CERTIFICATE OF INSURANCE COVERAGE p Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART1,To be completed by NYS disability and paid Family Leave benefits carrier or for licensed insurance agent of that carrie�t 1 a Leg al Name&Address of Insured use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 747C SOUND AVE MATTITUCK, NY 11952 1 c. Federal Employer Identification Number of Insured or Social Security Number certain locations in New York State,i.e., Wrap-Up Policy) ed to '� Or Location 0 Insured(Only required if coverage is specifically limited _ ...M. WW ...-... 2. Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company rOWN OF SOUTHOLD 54375 MAIN STREET 3b.Policy Number of Entity Listed in Box"1a" SOUTHOLD, NY 11971 DBL567527 3c. Policy effective period 01/01/2024 to 12/31/2025 4. Policy provides the following benefits: ® A..Both disability and paid family leave benefits. ❑ B.Disability benefits only. C,Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under i f am an Tu—lhnzed insured has NYS Disability and/or i aid Family Leave Benefits insurance coverage as described abovnsed�agent of the e. Gamer referenced above and that the named Date Signed 7/10/2024 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title LestOrt Welsh Chief Executive Officer IMPORTANT. If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 48, 4C or 56 is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers"Compensation Board (only it Box 48,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers`Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DE-120.1 (12-21) I ill III r . (_� III _II IIII IIII{I Ills I IIIIII I III 17--09*k& N' YSIF New York State Insurance Fund PO Box 66699,Albany; NY 122C6 nysif.com CERTIFICATE QE WORKERS' COMPENSATION INSURANCE (RENEWED) 11^ ^A^^ 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 962287 07/13/2024 TO 07/13/2025 7/11/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH T01 RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITIE AT HTTPS://WWW.NYSIF.COM/CERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND 4 o DiRECTOR,INSURANCE;=UN_D UNDEP,'IVRITING 7�_v_ Page 1 of 2 SSe.��►� 51937 Current 03/02/2025 Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Stathoudakis, Steve - 280 The Short Lane Project Address: 280 The Short Lane, East Marion, NY, 11939 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A �P.�EOF NE�yYO Zq�y���y.P�r Current Renewables Engineering Inc. EZ Professional Engineer info@currentrenewableseng.com A 101084 AR FE IONP Exp.01/31/2028 Signed on:03/02/2025 3600 Lime St Bldg 2,Ste#224, Riverside,CA 92507 (951)203-5933 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x12 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 30 degrees and has a max beam span of 19.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 3600 Lime St Bldg 2,Ste#224, Riverside,CA 92507 (951)203-5933 info@currentrenewableseng.com OF NEW ROOF MOUNT SOLAR PERMIT PACKAGE �APPa H ZAHo�yO;P, STEVE STATHOUDAKIS * ti 14.875 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 101084 FQp� � 280 THE SHORT LN, EAST MARION, NY 11939 FE IONP Exp.01/31/2028 STAMPED 03/02/2025 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC PRIOR WRITTEN APPROVAL FROM CURRENT POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY RENEWA13LES ENGINEERING INC SOLAR PHOTOVOLTAIC INSTALLATION 2020 BUILDING CODE OF NEW YORK STATE 2 THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 2020 RESIDENTIAL CODE OF NEW YORK STATE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED Current 2020 EXISTING BUILDING CODE OF NEW YORK STATE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE Renewabies 2020 FIRE CODE OF NEW YORK STATE UNDERSIGNED (� A 2017 NEW YORK STATE ELECTRICAL CODE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND Engineering U L 1703 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT CURRENT RENEWABLES ENGINEERING INC. SUCH AS GEO CEL 2300 CLEAR SEALANT 3600 Lime Street Bldg 2 Riverside,CA 92501 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL Email:Projecls�creng.solar Website www cre ng.co JURISDICTION AND THE UTILITY IS OBTAINED PHONE (951)-204-5492 AHJ: TOWN OF SOUTHOLD 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL,OR BUILDING ROOF VENTS CONTRACTOR INFO 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE LEGEND 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE uM UTILITY METER PM PRODUCTION METER MANUFACTURER'S INSTALLATION INSTRUCTIONS"< 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA CZ S I\/ S` MSP MAIN SERVICE PANEL wV INVERTER REGULATIONS 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" ELEMENT ENERGY LLC BUILDING INFORMATION 747050UND AVENUE,MATTITUCK, C❑ COMBINER � JUNCTION BOX 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. NEW YORK,11952 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PH:(631)7797993 AC DISCONNECT ❑ GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. services-ME-52689 2 STORY HOUSE SINGLE FAMILY RESIDENCE sub SUB PANEL Licence-ELECTRICIAN) 15, MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. (MASTER ELEcrRICIAN) ❑ MODULE 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. Licence-HI-67461 CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER (SUFFOLK HOME IMPROVEMENT) ROOF OBSTRUCTIONS THE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IQ IQ CONTROLLER 2 IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. STEVE STATHOUDAKIS APN : 1000030000200000000 ® 36"ACCESS PATHWAYS 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" BATTERY ABOVE ROOF SURFACE. 280 THE SHORT LN,EAST ATT ® 18"ACCESS PATHWAYS 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL MARION, NY 11939 SHEET INDEX QH Q.HOME HUB BE RATED FOR EXPOSURE,TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS. AHJ TOWN OF SOUTHOLD ROOF ACCESS POINT WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS PV-11.0 COVER PAGE AC ESS DISCONNECT THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT MBE MAIN BREAKER 20. MATERIALS, EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, UTILITY PSEG LONG ISLAND PV-2.0 SITE PLAN ENCLOSURE STANDARDS, RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE PV SUMMARY AUTOMATIC TRANSFER C LOAD CENTER PV-2.1 ROOF PLAN Ts L_ TO THE PURPOSE INTENDED: SYSTEM SIZE STC azs X 35 =14 875 SWITCH (KWDC) PV-3.0 STRUCTURAL 0 SEPTIC TANK PTC 398.1 X 35 =13.934 PV-4.0 ELECTRICAL 3LD © PERMANENT ANCHOR LEACH LINES SYSTEM SIZE(KWAC) 11,20 @240 JINKO SOLAR PV�.1 ELECTRICAL SLID WIND SPEED 128 MODULES 35 iKM425N-54 TO TEMPORARY ANCHOR PROPANE TANK SNOW LOAD 25 ENPHASE 54HL4-B MICROINVERTER 35 IQ8MC-72-M-US PVA.2 ELECTRICAL PHOTOS IL 0 WELL INSTALLER LADDER EXPOSURE CATEGORY C PV-5.0 BOM (� POWER LINES PV-6.0 SIGNAGE & PLACARD S❑ STUB-OUT NO LADDER ACCESS PV-7.0 SPECS+ ® SKYLIGHT (STEEP GRADE OR GROUND LEVEL Rev Description Date RESTRICTED ACCESS OBSTRUCTIONS) 0 INITIAL DESIGN 2/2 812 02 5 As GAS SHUT OFF A B - CONDUIT Hzo WATER SHUT OFF PROJECT# NA DATE DRAWN 2/28/2025 O7 SERVICE DROP DRAWN BY ER SHEET* PV-1.0 RAIL -- TITLE RAFTER ATTACHMENTCOVER PAGE R324.6.1 PATHWAYS: OF NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON �, � A SEPARATE ROOF PLANES, I __ __ 76"_C 1 LEGEND • l H ZA 0 FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON �'---- C7 BPS NQ ALL BUILDINGS. I * P y * AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR 1 UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. I FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM 11 SP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING 2 THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE PROPERTY LINE —I C❑ COMBINER �O e 10101 OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS I AC DISCONNECT pT f 14NQ` ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT. I MODULE •. Exp.01/31/2028 R324.6.2 SETBACK AT RIDGE: i ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 'ti STAMPED 03/02/2025 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN ® 36"ACCESS PATHWAYS AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A 1 '• • ' THESE DRAWINGS ARE SUBJECT TO COPYRIGHT • � PROTECTION BY US LAW. REPRODUCTION IN HORIZONTAL RIDGE. I .•! , ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 , 1�• _ 18' ACCESS PATHWAYS PRIOR WRITTEN APPROVAL FROM CURRENT PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A RENEWABLES ENGINEERING INC. 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A ROOF ACCESS POINT HORIZONTAL RIDGE. FENCE 1521-4n = ::. - R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS ' •:.�.:•� Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED 1 ole 5 THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE Engineering AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE 1 •r� PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. i ; CURRENT RENEWABLES ENGINEERING INC. NOTES: 1 •••' 3600 Lime Street,BIdg 2 Ri—ide,CA 92501 Email:Projects@creng.solar 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL 1 •' •! Website w .creng.co SITE CONDITION AND MEASUREMENTS. I .::: PHONE 951>-204-5492 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED _ CONTRACTOR INFO INTO THE 2017 NEC AND UL STANDARD 1741. y 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. I OI •t.R O M 1 , p ' `" EZSYS I' • •� ELEMENT ENERGY LLC. FENCE/GATE 7470 SOUND AVENUE,MATTITUCK, ROOF ACCESS POINT NE 11952 IPH:(631)31)779 7993 FENCE/GATE II se"ices@e2sys.com (MASTER ELECTRICIAN) , Licence-HI-67461 •. 1 1 O 1-711 (SUFFOLK HOME IMPROVEMENT) 6-811 ' ROOF LINE I STEVE STATHOUDAKIS ENLARGED VIEW I ROOF OBSTRUCTION 280 THE SHORT LN,EAST i MARION, NY 11939 1 I 1 AHJ TOWN OFSOUTHOLD 1 1 • I 1 AC • UTILITY PSEG LONG ISLAND ' 'r I OOF ACCESS POINTSYSTE PvsuMMARY I t •y - ; I KWDCM SIZE STC 425 X 35 = 4.875 ENLARGED VIEW 1 , PTC 398.1 X 35 = 1934 �' ;. • 1 SYSTEM SIZE 1120 @240 C i ••.••' ••' }• 1 MODULES 35 1KM0 SOLAR 4HL4-8 M S P : .• ..� 1 11 EN PHASE 1 t '.85 —2 I MICROINVERTER 35 108MC-72-M-US ' � 'a•;DRIVEWAY ..�; .:� � 1 - •r 1 •'• .., I Rev Description Date LL I ~,•.• . '• -• ,� 1 PROPERTY LINE OA INITIAL DESIGN 2/28/2025 UM / 1 Y:: 1 B 1 `' •• .• ::�,: PROJECT# NA DATE DRAWN 2128/2025 SITE PLA�1 -0- ENLARGED VIEW —� --�— —75'-11"• — -- I— DRAWN BY ER 75 �— SHEET# PV-20 &�SCALE- TITLE 1/32" = THE SHORT LN SITE PLAN ARRAY AREA LEGEND P��OF NEW,,,o ARRAY ROOF ROOF TOTAL �'t �PgN ZAN .P' ROOF #OF AREA AREA ROOF AZIMUTH AREA AREA uM UTILITY METER * Q y TILT MODULES COVERED BY COVERED BY (Sq.Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) SP MAIN SERVICE PANEL � #1 30° 244° 28 1 588.56 3872 15.20 1 ? W 19.00 C❑ COMBINER 154° 7 147.14 1 3872 3.80 �C AC DISCONNECT (n0 101084 MODULE A� FE 10NP ROOF OBSTRUCTIONS Exp.01/31/2028 ROOF#1 _ _ 36"ACCESS PATHWAYS STAMPED 03/02/2025 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT _ 18"ACCESS PATHWAYS PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR VFrEN RAIL REN WABLESPEN ENGINEERING RENT NG NC RAFTER ATTACHMENT Current Renewabies Engineering CURRENT RENEWABLES ENGINEERING INC. _ 3600 Lime Street,Bldg 2 Riversitle,CA 92501 Email:Projects@cmng.solar _ -- - Websde —creng.co PHONE. 951)-204-5492 CONTRACTORINFO (N)35 JINKO SOLAR JKM425N-54HL4-Ba1mr — / CZSYSS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK, STRUCTURAL NOTES: _ PH:631)7791 91952 93 r-611 services@e2sys.com 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE _ _ — Licence-ME-52689 (MASTER ELECTRICIAN) COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE Licence-HI-67461 PROPOSED PV INSTALLATION ONLY. _ _ — (SUFFOLK HOME IMPROVEMENT) 2.THESE PLANS ARE NOT STAMPED FOR WATER _ _ _ I STEVE STATHOUDAKIS LEAKAGE. 3. PV MODULES, RACKING, AND ATTACHMENT _ _ 280THE SHORT11 EAST 939 COMPONENTS MUST FOLLOW MANUFACTURER — _ I f MARIOS UT OLD GUIDELINES AND REQUIREMENTS. AFiJ TOWN OFSOHLD 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL _ _ _ CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. I I UTILITY PSEG LONG ISLAND 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR PVSUMMARY INSTALLER SHALL VERIFY THE ROOF FRAMING INFO I I I SYSTEM SIZE (KWDC) STC 425 X 35 = 4.675 BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE 110— _ 41 SYSTEM SIZE PTC 3981 X1351= 3.934 IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION _ _ i (KWAC) 11,20 @240 IN AND FOLLOWING:2x12 RAFTERS @ 16"OC SPACING WITH ECC MODULES 35 1. SOLAR JKM425N-54HL4-B MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 19 FT. M P ' MICROINVERTER 35 ENPHASE I CA72-M-US ROOF#2 Rev Description Date 0 INITIAL DESIGN 2/28/2025 I6 A B PROJECT# NA r- ___________ DATE DRAWN 2/28/2025 I ROOF PLAN THE SHORT LN ' ' DRAWN BY ER 2 SHEET# PV-2 1 L n I TITLE SCALE: 1/8" = 1�-0to �____________J ROOF PLAN TABLE 1 TABLE 2 ��OF NEWy , s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX C' V P5H Zgp0, NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG s2 ATTACHMENT IRONRIDGE HUG ROOF 1 30° COMP SHINGLE RAFTER 2"X12" 16" 64" 24" r � s3 RAIL IRONRIDGE XR-100 RAIL 751 ROOF 2 30° COMP SHINGLE RAFTER 2"X12" 16" 64" 24" 2 101084 AR FE IONP Exp.01/31/2028 STAMPED 03/02/2025 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC Current gables ' Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Stmet,Blog 2 Riverside,CA 92501 Emil:Pmjects(BJcreng.solar Websde:w 1,;omng.co MODULE PHONE: 95}24-5492 CONTRACTOR INFO S3 TABLE asm S2 GUIDE FOR NSTALOLN C2SY5vA ELEMENT ENERGY LLC. ROOF TWO OR MORE ROWS OF PANELS 7470 SOUND AVENUE.MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 2.5"MIN.EMBED. I I I I I I I I I I I I I I I I I I I ( I I I I I I I I I I I I I I I I I I STEVE STATHOUDAKIS 280 THE SHORT LN,EAST (2)-#14 X 3" SELF DRILLING MARION, NY 11939 STRUCTURAL SCREWS TO I I I I I I I I I I I I I I I I I I AHJ TOWN OFSOUTHOLD Si EXISTING STRUCTURE I I I I I I I I I I I I I I I I I I I UTILITY PSEG LONG ISLAND PV SUMMARY ENLARGED VIEW STACKED STAGGERFD FULLY STAGGERED _. __ ___. SYSTEM SIZE(KWDC) STC 425 X 35 = 4.875 PTC 398.1 JX1351=fI3934 ONE ROW OF PANELS SYSTEM SIZE 1120 @240 (KWAC) MODULES 35 �INKO SOLAR „M/^/ IIKM425N-54HL4-B 6'r�I�►�•�� MICROINVERTER 35 IQ8MC-2-M-US MODULE I I I I I I I I I I I I I I I I I I I I I I I I SEE ENLARGED VIEW I FULLY STAGGERED STACKED/STAGGERED Rev Description Date 0 INITIAL DESIGN 2/28/2025 A _I B PROJECT# NA DATE DRAWN 2/28/2025 �- ROOF DRAWN BY ER SHEET• PV-3.0 TITLE ATTACHMENT DETAILS STRUCTURAL BACKFEED FUSE SIZING A MAX. CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST `'' PEL M 46.55 X 1.25 = 58.19AMPS 60A FUSES-OK S. NO. ITEMS DESCRIPTION QTY. UTILITY PSEGLI .v G JINKO SOLAR r- � 1 PV MODULE JKM425N-54HL4-B 35 METER NO. 98404286 IFn — 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 35 N _� 3 COMBINER ENPHASE IQCOMBINER 5 1 ACCOUNT NO. 9675016302 ( ° a8746% 60A RATED D222NRB �O SS)Ov, 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 sealed 05mar2025 mike@h2dc.com LOCKABLE NEMA 311 UL H2DC PLLC NY CoA#.PB-082933 LISTED ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET NOTE:THE CONNECTION BETWEEN THE PV PANEL (E)UTILITY METER TO UTILITY THESE DRAWINGS ARE SUBJECT TO COPYRIGHT AND MICRO-INVERTER IS VIA MC4 CABLE,WHICH IS PROTECTION BY US LAW REPRODUCTION IN PRE-INSTALLED BY THE MANUFACTURER GRID ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC.3 . (N) ENPHASE (E)150A RATED COMBINER BOX 5 MAIN SERVICE PANEL Current 1 PH,1201240V 60HZ �'�`[ n (E)150A/2P MAIN 0 +1'e s 2 A NIQ WIRE LESS ( FE BREAKER Engineering COMMS CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,BWg 2 Riverside.CA 92501 TEWAY Email:Projects@creng solar BRANCH 1 OF 12oNE 9s�zoa-s<s2 PV MODULE N T (N)15A�rn CONTRACTOR INFO BRANCH 2 OF 12 I (� N�2� I• (N)LINESIDE TAP VIA UL PV MODULE N I .� LISTED CONNECTOR 991mm— (N)20A' 'I I I _ J L -��/'\ I I 4 (N)FUSED (N)60A FUSE . C z SYSS (N)20A/I� AC DISCONNECT 7470 SOUND AVENUE,ELEMENT E RGY LLC. UCK, I I NEW YORK,11952 L_——————— Jl L—————— _—_ services@e2sys.com BRANCH 3 OF 11 0./ v Licence-ME-52669 (MASLicence-R HI 69461 N PV MODULE r--- J t I (SUFFOLK HOME IMPROVEMENT) B C STEVE STATHOUDAKIS MODULE JINKO SOLAR GEC COATED L——————————————— 280 THE SHORT LN,EAST MANUFACTURER #sAwG TO THE MARION,NY 11939 MAIN GROUND ROD (E)GROUNDING ELECTRODE _ MODULE MODEL JKM425N-S4HL4-B CONDUCTOR #6 BARE COPPER AHJ TOWN OF SOUTHOLD MODULE(W) 425 UTILITY PSEG LONG ISLAND MODULE PTC(W) 398.1 PV SUMMARY MODULE Isc(A) 13.58 SYSTEM SIZE STC 425 X 35 = 4 875 NOTE: (KWDC) MODULE Voc(V) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS i3.934 MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. SYSTEM SIZE(Kwnc) 11.zo @240 NOTE: 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH 11NKO SOLAR MODULE Vmp(V) 32.37 EGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE. PROPER JUNCTION BOX AT EACH END PER 690.31A MODULES 35 JKM425N-54HL4-B MICROINVERTER 35 ENPHASE IQ8MC-72-M-US WIRE CALCULATION STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT TAG QTY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (°C)DESCRIPTION FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS Rev Description Date IN RACEWAY 310.15(B)(3)(a) IN RACEWAY 0 INITIAL DESIGN 2/28/2025 A 6 12 SKU: Q-12-RAW-300,THHN N/A FREE AIR 30 90° 15.96 0.96 0.8 23.04 19.95 B 1 8 THWN-2 BARE COPPER-(GROUND) PROJECT# NA 3 6 THWN-2 COPPER-(L1,L2,N) DATE DRAWN 212812025 B 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 DRAWN BY ER 1 8 THWN-2 COPPER-(GROUND) SHEET# PV-4 0 TITLE THWN COPPER-(L1,L2,N) C 3 6 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 ELECTRICAL 3LD 1 6 THWN COPPER-(GROUND) BACKFEED FUSE SIZING OF NF MAX. CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST 5'�P�PEL M G,yq 46.55 ' X 1.25 = 58.19AMPS 60A FUSES-OK S. NO. ITEMS DESCRIPTION CITY. UTILITY PSEGLI JINKO SOLAR r: 1 PV MODULE JKM425N-54HL4-B 35 t METER NO. 98404286 1— R 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 35 N 3 COMBINER ENPHASE IQ COMBINER 5 1 ACCOUNT NO. 9675016302 ( `��16- 8748% 60A RATED D222NRBSSrDv,P 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 sealed 05mar2025 mike@h2dc.com LOCKABLE NEMA 3R UL H2DC PLLC NY CoA#:PB-082933 LISTED ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET NOTE:THE CONNECTION BETWEEN THE PV PANEL E UTILITY METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT AND MICRO-INVERTER IS VIA MC4 CABLE,WHICH IS ( ) TO UTILITY PROTECTION BY US LAW.REPRODUCTION IN PRE-INSTALLED BY THE MANUFACTURER GRID ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC 3 .. (N) ENPHASE (E)150A RATED COMBINER BOX 5 MAIN SERVICE PANEL Current 1 PH,120/240V 60HZ 1 (E)150A/2P MAIN CELL WIRE LESS BREAKER Engineering 2 A MODEM COMMS (TOP FED) CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 IQ GATEWAY Email:Projects@creng solar BRANCH 1 OF 12 PHONE 951,-204-5492 FPV MODULE N (N)15A�� CONTRACTOR INFO (N)20A�• •�• BRANCH 2 OF 12 .�• IN)LINESIDE TAP VIA UL PV MODULE N _ •�. LISTED CONNECTOR mum (N)20A� 4 . _ F • • (N)FUSED (N)60A FUSE Cc SYS8 (N)20A AC DISCONNECT •� •///TTT��� ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATfITUCK, •�• NEW YORK,11952 PH:(631)779 7993 "t./ v • services-ME-5 689 com Licence-ME-52689 (MASTER ELECTRICIAN) BRANCH 3 OF 11 Licence-HI-67461 PV MODULE N (SUFFOLK HOME IMPROVEMENT) g STEVE STATHOUDAKIS MODULE MANUFACTURER JINKO SOLAR 280 THE SHORT LN,EAST (E)GROUNDING ELECTRODE MARION, NY 11939 MODULE MODEL JKM425N-54HL4-B CONDUCTOR #6 BARE COPPER AHJ TOWN OF SOUTHOLD MODULE(W) 425 UTILITY PSEG LONG ISLAND MODULE PTC(W) 398.1 PV SUMMARY MODULE Isc(A) 13.58 SYSTEM SIZE NOTE: (KWDC) STC 425 X 35 = 4 875 MODULE Voc IV) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS PTC 398.1 IXI351=I13934 SYSTEM SIZE MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. (Kw,ac) 1120 @zag NOTE: 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH NKO SOLAR MODULE Vmp(V) 32.37 EGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE. PROPER JUNCTION BOX AT EACH END PER 690.31A MODULES 35 JKM425N-54HL4-B MICROINVERTER : 35 ENPHASE IQ81VIC-72-M-US WIRE CALCULATION STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENTMORE THAN 3 CONDUCTOR APPLIED TO TAG CITY. SIZE(AWG) DESCRIPTION SIZE&TYPE AMPACITY RATING (°C) APPLIED TO FACTOR 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS EDARAWN Description Date IN RACEWAY 310.15(B)(3)(a) IN RACEWAY INITIAL DESIGN 2/28/2025 6 12 SKU:Q-12-RAW-300,THHN A N/A FREE AIR 30 90° 15.96 0.96 0.8 23.04 19.95 1 8 THWN-2 BARE COPPER-(GROUND) NA 2/28/2025 3 6 THWN-2 COPPER-(L1,L2,N) B 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 ER 18 THWN-2 COPPER-(GROUND) PV-4.1 TITLE 3 6 THWN COPPER-(L1,L2,N) C 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 ELECTRICAL SLD 1 6 THWN COPPER-(GROUND) EXISTING SERVICE PANEL PHOTOS (2, OF NE 5��p.E� Mac o <v p87488 r-- +�1t sealed 05mar2025 mike@h2dc.com H2DC PLLC NY COATI:PB-082933 ELECTRICAL ONLY } � �� PRE CONSTRUCTION DRAWING SET 3 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT - PRIOR WRITTEN APPROVAL FROM CURRENT r7Ti RENEWABLES ENGINEERING INC. r Current 39 eables Engineering 40 CURRENT RENEWABLES ENGINEERING INC. 3600 Lime S met.Bldg 2 Riverside,CA 92501 Email Projects@creng.solar Website:—creng co PHONE: 951)-204-5492 CONTRACTOR INFO S' - - EZSYSA .y ate• ELEMENT ENERGY LLC. ..- 7470 SOUND AVENUE,MATTITUCK, NEW 11952 PH:(631)31)77 779 7993 All P s icen e-ME-52689 Licence-ME-52689 (MASTER ELECTRICIAN) �` Licence-HI-67461 j(+� 'til� (SUFFOLK HOME IMPROVEMENT •-� STEVE STATHOUDAKIS 280 THE SHORT LN,EAST MARION, NY 11939 AHJ TOWN OFSOUTHOLD UTILITY PSEG LONG ISLAND - II PV SUMMARY 1 SYSTEM SIZE STC 425 X 35 = 4.875 (KWDC) PTC 398.1 IX1351= 3.934 SYSTEM SIZE _ 11.20 @240 (KWAC) f � MODULES 35 IIKM4t IN KO SOLAR K M425 N-54-54HL4-B MICROINVERTER 35 ENPHASE owl • I` IQSMC-72-M-US � s Rev Description Date 0 INITIAL DESIGN 2/28/2025 I A B PROJECT# NA DATE DRAWN 2/28/2025 • DRAWN BY ER SHEET# PV-4.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST ELECTRICAL EQUIPMENTS QTY. PART TYPE PART NUMBER DESCRIPTION 35 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B 35 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US 1 AC DISCONNECT D222NRB 60A RATED 240VAC NEMA 3R UL LISTED 1 COMBINER X-IQ-AM1-240-5 Enphase IQ Combiner 5 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS PROTECTION BY US LAW REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current n Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street.Bldg 2 Riverside.CA 92501 Email-.Projects@crengsolar Websoe vrv+w.creng.cc PHONE.(951)-204-5492 CO NTRACTORINFO BREAKER / FUSES CZSYSAU QTY. PART TYPE PART NUMBER DESCRIPTION ELEMENT ENERGY LLD. 7470 SOUND AVENUE,MATTITUCK, 2 FUSES 60A FUSES GENERAL 60A FUSES NEW YORK,11952 PH.(631)7797993 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) services-ME-Y5 com Licence- E-52669 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) STEVE STATHOUDAKIS 280 THE SHORT LN,EAST MARION, NY 11939 RACKING AHJ TOWN OF SOUTHOLD QTY. PART TYPE PART NUMBER DESCRIPTION UTILITY PSEG LONG ISLAND 42 RAILS & SPLICES XR-100-168B XR-100, 168" (14') BLACK PVSUMMARY SYSTEM SIZE (KWDC) STC 425 X 35 =14.875 18 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 PTG 3981 IX1351=113934 SYSTEM SIZE 1120 01240 46 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK KWAG) MODULES 35 JINKO SOLAR 1 K M425N-54HL4-B 48 CLAMPS & GROUNDING UFO-END-01-B1 END FASTENING OBJECT (END CLAMP, 30-40MM), BLACK MICROINVERTER 35 ENPHASE IQ81VIC-72-M-US 12 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 108 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK 216 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.01- 108 ATTACHMENTS BHW-SQ-03-Al SQUARE BOLT, BONDING HARDWARE Rev Description Date 0 INITIAL DESIGN 2/28/2025 A B PROJECT# NA DATE DRAWN 2/28/2025 DRAWN BY ER SHEET# PV-5 0 TITLE BOM CAUTION �EOFNw 5'��p.EL Mac MULTIPLE SOURCE OF POWER PHOTOVOLTAIC SYSTEM, M Fn EQUIPPED WITH RAPID SHUTDOWN p87485 � O�SSIO�: 690.12 sealed 05mar2025 mike@h2dc.com H2DC PLLC NY CoAk PB-082933 ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET WIT7RAPID HUTDOWN PV ARRAY THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN 1 ; ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT TURN RAPID _V SYSTEM AC ,ISCNNECT• PRIOR WRITTEN APPROVAL FROM CURRENT RENE WABLES ENGINEERING INC. SHUTDOWN SWITCH TO RATED AC OUTPUT CURRENT46.55 AMPS THE "OFF" POSITION TO AC - •- •- • • Current AC DISCONNECT Renewabtes SHUT DOWN PV SYSTEM 690.14,690.15,690.54 AND REDUCE SHOCK COMBINER Engineering WARNING CURRENT RENEWABLES ENGINEERING INC. HAZARD IN THE ARRAY PM 3600 Lime Street,Blag2Riversioe,CA 92501 � -• _ • - Email Projects�c2ng solar 690.56(C)(1)(B) SECMAIN SERVICE PANEL Website w creng co • , SOURCE _ PHOTO- • • VOLTAIC , PHONE:(951)-204-5492 CONTRACTOR INFO RATED AC OUTPUT CURRENT ♦ - ELECTRIC SFIOCK HAZARD AC NORMAL OPERATING VOLTAGE - 240 VOLTS 00 NOT TOUCH TERROW" �.. TFJtIlWLS ON BOTH LIE L LOAD SIDES MAYBE ENERGIZED INOPEN POSITION DO HOT DISCONNECTER FUSES UNDER Loan 69054 E Z SYSU "HoTovo'°"DSYSTEMFN A'�ED OPTIONAL SOLAR LOAD CENTER PHOTOVO110 y=EA/rE UN01101IO®AIO rAYtE t ELEMENT ENERGY LIEC PHOTD%OLTA1C$flnM ARRAY 7470 SOUND AVENUE,MATiITUCK DC DMCONI� NEW Y 11952 PH:(631)779 7993 AUTHORIZED PERSONNEL ONLY UTILITY METER Q services@e2sys.com Licence-ME-52669 Nate:WARNING III must resemble format _ ... (MASTER ELECTRICIAN) inwomple above wdh over-sized WARNING. Licence- �a x �� �n >a THE SHORT LN (suFFOLKHOME IMPROVEMENT) mcclarnabon point in triage,colas,etc. m, an a. ati PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL STEVE STATHOUDAKIS PANEL IS AC DISCONNECT PER NEC690.17 280THE SHORT LN,EAST INVERTER ARNING"OUTPUT _ • • MARION,NY 11939 AHJ TOWN OF SOUTHOLD D• NOT RELOCATE THIS NEC 690.31(G)(3)8(4),CRC R324.7 UTILITY PSEG LONG ISLAND OVERCURRENT DEVICE "WARNING" PV SUMMARY (UNLESS BUSBAR IS FULLY RATED) L — _ • UVOLTAIC POWER • _ SOURCE _ SYSTEM SIZE sic azs x 35 = 4.875 KWDC) 705.12(D)(2) PTc 398.1 X 35 =b3 934 SYSTEM SIZE(KWAC) 11.20 @240 EVERY 1U ON CONDUIT AND ENCLOSURES MODULES 35 11NKO SOLAR 1 KM425N-54HL4-B MICROINVERTER 35 ENPHASE NOTES APPENDIX(AS APPLICABLE FOR TO BE BUILT DRAWING SETS):(A)TOTAL AC VOLTAGE DROP NOT TO EXCEED 2%TO QaMC-72-10-1-15 INTERCONNECTION,<3%FROM INVERTER(S)TO UTILITY TRANSFORMER. (B)ALL CONNECTORS 75C RATED.(C)ALL CONDUCTORS COPPER,UNLESS OTHERWISE NOTED.(D)OUTDOOR EQUIPMENT NEMA3R.(E)ALL CONDUCTORS MUST BE PROTECTED FROM ACCESS BY NOTES: A FENCE OR SUITABLE COVER,OR OUT OF REACH.(F)PROPERTY LINES, BOUNDARIES AND ALL OTHER EXTERIOR MEASUREMENTS ARE FOR REFERENCE ONLY,AND MUST BE VERIFIED BY A LICENSED SURVEYOR OR CIVIL ENGINEER. (G)NO PVC ALLOWED ON ROOF OR IN 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS ATTIC. (H)MC4 CONNECTORS MAY NOT BE JOINED WITH'MC4 COMPATIBLE'CONNECTORS. (I)TAP CONNECTIONS IN PANEL MUST NOT SHOWN HEREON. VIOLATE CONDITIONS OF ACCEPTABILITY FROM PANEL MANUFACTURER'S NRTL LISTING,OR FIELD LABEL REQUIRED.(J)PV WIRES MAY NOT BE LAID DIRECTLY ON ROOF. (K)TY WRAPS FOR WIRE MANAGEMENT MUST BE STRUCTURAL(S21)UL APPROVED,OR EQUAL.(L) 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date DRAWINGS ARE DIAGRAMMATIC AND INDICATE GE-NERAL ARRANGEMENT OF SYSTEMS AND WORK.-CONDUIT ROUTING,WHEN INDICATED, A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR 0 INITIAL DESIGN 2/28/2025 DOES NOT SHOW ALL OFFSETS,DROPS,AND RISES OF RUNS.(M)BURIED CONDUITS UNDER AREAS SUBJECT TO VEHICLE TRAFFIC MACHINE PRINTED LETTERS OR ELECTRO-PLATING. A REQUIRE MIN 24"COVER. (N)NM-B OR PAPER INSULATED CONDUCTORS MAY NOT BE USED EXTERIOR. (0)THE DEVELOPER IS REQUIRED B. RED BACKGROUND COLOR WHITE TEXT AND LINE B TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE FROM THE UTILITY,AND MAY NOT RELY S-OLELY ON EXISTING BREAKER SIZES.(P) PROJECT# NA CONNECTING TO UTILITY EQUIPMENT REQUIRES PRIOR UTILITY CONSENT.(Q)WHEN BUILDING PV SYSTEMS WITH POWER LINE WORK. COMMUNICATIONS FOR RSD SOLUTIONS, FOLLOWING MANUFACTURERS INSTRUCTIONS ON CONDUCTOR AND CONDUIT SPACING IS C. AERIAL FONT. DATE DRAWN zizfirzozs PARAMOUNT,OR HAZARD MAY RESULT.(R)NOTIFY ELECTRICAL ENGINEER WHO'S SEAL IS ON THIS DRAWING PRIOR TO ANY AND ALL 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN By ER CHANGES IN DESIGN.(S) PROJECT RELATED SIGNAL/COMMUNICATION CONDUCTORS MAY ONLY BE RUN IN THE SAME CONDUIT WITH THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-60 POWER CONDUCTORS IF THEIR RATING FOR THE OUTER MOST JACKET IS EQUAL TO OR GREATER THAN THE INSULATION REQUIRED FOR TITLE THE HIGHEST VOLTAGE POWER CONDUCTOR CIRCUIT THAT THEY ARE SHARING THE RESPECTIVE CONDUIT WITH. HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS Front Side Back EAGLE 1134- s No.of Half Cells 108 12 x 541 M O D U L E S i - --- - - - __-. Dimensions 7722=7736 x 35mm 167.79 x 44.65 x 1.38 inch) x Weight 22 Okg 148 Slbsl THEMOST Front Glass Anti-Reflection Coating High T High Transmission,Low Iron.Tempered Glass Frame Anodized Aluminum Alloy THESE DRAWINGS ARE SUBJECT TO COPYRIGHT DEPENDABLE e. ,„ PROTECTION BY US LAW. REPRODUCTION IN ,. Junction Box IP68 Rated ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT e �'' `� a PRIOR WRITTEN APPROVAL FROM CURRENT Output Cables 12 AWG,1400mm I55.12in1 or Customized Length RENEWABLES ENGINEERING INC. SOLAR P R O D U CT Connector Staubt,MC4 Fire Type Type 1 +^ t Pressure Rating 540OPa(Snow18240OPaIWindl "�r�� ` EAGLE 54HM G 6 --- -- Engineering TEMPERATURE CHARACTERISTICS CURRENT RENEWABLES ENGINEERING INC. 420-440 WATT • N-TYPE TOPCON ___-_ __ Temperature Coefficients of Pmaz 0.29'h/°C 3600 Lime Stmet,Bldg 2 Riverside,CA 92501 [ �J - -- Length: Email:Projects@cmng solar Welosite reng co Positive OWe�tolerance OI O +JO�O = ±dI(►yt' - Width:t2mm Temperature Coefficients of Yoc 025%/°C PHONE www 04-5492 P a u+ y 9 Temperature Coefficients of Isc 0.045%1°C PHONE 951)-204-5492 Height-t tmm - Row Pitch:t 2mm CONTRACTOR INFO Nominal Operating Cell Temperature INOCTI 45t2°C • NYSE-listed since 2010,Bloomberg Tier 1 manufacturer --"- --" • Top performance in the strictest 3"party labs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE { MAXIMUM RATINGS � - - • Automated manufacturing utilizing artificial intelligence Current-Volta e&Power-Volta a Temperature Dependence C2 SYSAU 9 9 Operating Temperature I°CI -40°C-+85°C U • Vertically integrated,tight controls on quality Curves 144011111 w of Isc,Voc.Pmax Maximum System Voltage 11000VDC ELEMENT ENERGY LLC. • Premium solar factories in USA,Vietnam,and Malaysia a -u Maximum Series Fuse Rating 25A 7470 SOUND AVENUE,MATTITUCK, w _- s NEW YORK,11952 PH:(631)779 7993 an y services@e2sys.com �rm 89 KEY FEATURES ` ° __ _-�° PACKAGING CONFIGURATION Licence- ECTRI IA ! (MASTER ELECTRICIAN) - - w Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) OSuperior Aesthetics 1e S a r�- [Two paUets=One stack] Black backsheet and black frame create ideal look for •• 31pcs/pallets,62pcs/stack,806pcs/40 HO Container $TEVE STATHOU DAKIS residential applications. Voltage IYI g m 280 THE SHORT LN, EAST O N-Type Technology MARION, NY 11939 N N-type cells with Jinko's in-house TOPCon technology • . s > '. WARRANTY offers better performance and improved reliability Ceti Temperature 1°CI 25-year product and 30-year linear power warranty AHJ rowN of sourHOLD (D Thick and Tough I 11'year degradation not to exceed 1%,each subsequent year not to Fire Type 1 rated module engineered with a thick frame, ! exceed 0.4%,minimum power at year 30 is 87.4%or greater. UTILITY PSEG LONG ISLAND 3.2mm front side glass,and thick backsheet for added durability. = -. - _ ___ __ PV SUMMARY SYSTEM SIZE . STC 425 X 35 =14.875 0 Shade Tolerant ELECTRICAL CHARACTERISTICS (KWDC) Twin array design allows continued performance Module Type JKM42ON-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-B JKM435N-54HL4-8 JKM440N-54HL4-6 SYSTEPTC 398 1 X 35 -13.934 even with STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT (KWAC)shadirq by trees or debris. slzE 11 20 @240 (KWAC) Protected Against All Environments Maximum Power(Pmazl 420Wp 316Wp 425Wp 320Wp JINKO SOLAR 430Wp 323Wp 435Wp 327Wp 440Wp 331Wp MODULES 35 JKM425N-54HL4-B ertifted to withstand humidity,heat,rain,marine environments. Maximum Power voltage lvm ) 32.16V 29.95V 32.37V 30.19V 32.58V 30.30V 32.78V 30.50V 32.99V 30.73Y EN PHASE 0wind,hailstorms.and packed snow. 66A 13.27A 10.72A t3.34A 10.77A Q y p MICROINVERTER 35 ISMC-72-M-US Maximum Power Current limp] 13.06A 1C.55A 13.13A 10.60A 13.20A t0. Warranty Open-circuit Voltage Ivocl 38.74V 36-BOV 38.95V 37.00V 39.16V 37.20V 39.36V 3T39V 39.57V 37.59V 25-year product and 30-year linear power warranty. Short-circuit Current Itsc; 13.51A 10.91A 13.58A 10.96A 13.65A 1.02A 13 72A 11.08A 13.80A 11.14A Module Efficiency STC(%) 21.51% 21,76% 22.02% 22.28% 22.53% - - *STC: * Irradiance 1000W/m2 j Cell Temperature 25°C cf� AM=1.5 Rev Description Date • 15090014015 Quality Standards • 15045001:2018Occupational w Z ®� NI • Irradiance 800W/m2 j Ambient Temperature 20°C � AM=1.5 Wind Speed 1m/s o INITIAL DESIGN 2/2812025 • IS014001:2015 Environmental Standards Health 8 Safety Standards L� i CE CE A ,a...:P *Power measurement tolerance:t3% • IEC61215,IEC61730 certified products UL61730 certified products __-�. �� -- -- B S The company reserves the final right for explanation onany of the information presented hereby.JKM420-440N-54HL4-B-FI-US j p q PROJECT# NA BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US -1jn«0 BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US .Jinl 0 DATE DRAWN 2/28/2025 DRAWN BY ER ISHEET* PV-7D TITLE MODULE SPEC ENPHASE IQ8MC Microinverter INPUT DATA iDC� UNITS 108MC-72-M-U5 Commonly used module pairings IN 260-460 wModule compatibility To meet compatibility.PV modules must be within the following max.input DC voltage and max.module IK Module compatibility can be checked at http&//enphme.com/instaliers/micro,n ortem/calculator. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT MPPT voltage range V 25-45 PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT Operating range V 18-58 PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. MinJMax.start voltage v 22/58 Max.input DC voltage v 60 Current Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 t Max.module I A 20 Engineering Overvoltage class DC port II CURRENT RENEWABLES ENGINEERING INC. 3600 Lime StreelBklg 2 Riverside,CA 92501 DC port backfeed current mA 0 Email:Projects@raeng.solar Websile www.creng.co PV array configuration Ungrounded array;no aci tional DC side protection required;AC side protection requires max 20 A per branch circuit PHONE. 951)-2045492 CONTRACTOR INFO Peak output power VA 330 315 Max.continuous output power vA 320 310 Nominal grid voltage(L-L) v 240.split-phase(L-L).1W 208,single-phase(L-0.1201 almm Q8 M C Microinverter Easy to install Mir,./Max.grid voltage' v 211-264 183-229 r a•— Our newest 108 Series Microinverters are the industry's first microgrid-forming'.software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 CF.SYSA defined miCroinvert and-play connectorsers with split-phase power conversion capability to convert DC power to Nominal frequency H= 60 ELEMENT ENERGY LLC. AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) 7470 SOUND AVENUE,MATTRUCK, application-specific integrated circuit(ASIC).which enables the microinverter to operate in between components Extended frequency rangy H: 47-68application-specific Faster installation with simple grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed AC short cvcuit fault current over three PH:(631) • A„- 2.70 services@e2sys.co2s .com digital logic and has superfast response times to changing bads and grid events,alleviating cycles Licence-ME-52689 constraints on battery sizing for home energy systems. cabling Max.units per 20 A(L-L)branch circuit2 10 (MASTER ELECTRICIAN) ' 1 Licence-HI-67461 High productivity and reliability Total harmonic distortion 5 (SUFFOLK HOME IMPROVEMENT) 9E < Enphase Produces power even when the grid is down' Overvoltage class ACport ,u STEVE STATHOUDAKIS More than one million cumulative hours AC port back feed current mA 18 280 THE SHORT LN,EAST of testing MARION,NY 11939 Power factor setting in Part of the Enphase Energy System, 108 Series Microinverters redefine Class 11 double-insulated enclosure Grid-tied power factor(adjustable) 0.851eading...0.851agging AHJ TOWN OF SOUTHOLD I08 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway.and the million cumulative hours of power-on PV modules Peak efficiency % 9za 97.2 Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency % 97.0 96 5 UTILITY PSEG LONG ISLAND software. limited warranty of up to 25 years. Micr fd-formi � rig Nighttime power consumption mW 33 25 PV SUMMARY Complies with the latest advanced grid SYSTEM SIZE MECHANICAL.. STC 425 X 35= 4.875 support Ambient temperature range -40°C to 65`C(-40'F to 149T) PTC 398.1 X 35 = 3.934 • Remote automatic updates for the SYSTEM SIZE latest grid requirements Relative humidity rarge 4%to 100%(condensing) (KWAC) : 11.20 NKO • Configurable to support a wide range DC connector type Staubii MC4 MODULES 35 IIKM4 SOLAR KM425N-54HL4-B Of grid profiles Dimensions(H-W•D);Weight 212 min(8.3")•175 in(6.9")"30.2 min IQSM (1.2");1.1 kg(2.43 Ibs) MICROINVERTER 35 ENPHASE Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed C-7z-M-US to the 108 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations:Pollution degree Yes:PD3 installed according to the manufacturer's instructions. Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure NOTE: • 108 Microinverters cannot be mixed together with Environ.category;UV exposure rating NEMA Type 6:outdoor prev us generations of Enphase mioro—iters COMPLIANCE (107 Senes.106 Senes.etc.)in the same system. 10 Gateway is required to change the default grid CA Rule 21(UL 1741-SA).UL 62109-1.IEEE 1547:2018(UL T741-SB).FCC Part 15 Class B.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1.01 Rev Description Date -Meets UL 1741 only when installed with 10 System Controller 2 and 3. profile at the time of instaltation to most the local Certifications This product is UL Listec as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017.NEC 2020,and NEC 2023 section 690.12 and 0 INITIAL DESIGN 2/282025 Authority Having Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 a*shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. A O 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos IQ and certain other marks listed at (1)No enforced DC/AC ratio. —ps__ra Qhasecdn/trademark-rrsage-gudekne,are trademarks of Enpfuse F—gy.Inc.in the US and other countries. (2)Nominal voltage range can be extended beyond nommal H repaired by the utility. Data subject to chanDa. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 (3)Limits may very.Refer to local requirements to define the number of microinverters per branch in your area. 108MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 PROJECT# NA DATE DRAWN 228/2025 DRAWN BY ER SHEET* PV-7 1 TITLE MICROINVERTER SPEC ENPHASE. ® IQ Combiner 5/5C MODEL NUMBER _ IQ Combiner 5 with 10 Gateway printed circuit board for integrated revenue-grade PV IQ Combiner 5 production metering(ANSI C12.20±0.5%).consumption monitoring(±2.5%),and IQ (X-I0-AMl-240-5/X-IQ-AMl-240-5-HDK) Battery monitoring(±2.5%).Includes a silver solar shield to deflect heat. IQ-AM1-240-5-HDK includes a factory installed hold-down kit compatible with all the ENPHASE circuit breakers mentioned in the Accessories and Replacement Parts section. IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production metering(ANSI C12.20±0.5%),consumption monitoring(±2.5%).and THESE DRAWINGS ARE SUBJECT TO COPYRIGHT IQ Combiner 5C IQ Battery monitoring(±2.5%).Includes Enphase Mobile Connect cellular modem PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT (X-10-AM1-240-5C/ X-IQ-AM1-240-5C-HDK) (CELLMODEM-Ml-06-SP-05)'.Includes a silver Solar shield to deflect heat. PRIOR WRITTEN APPROVAL FROM CURRENT IQ-AM1-24C-5C-HDK includes a factory installed hold-down kit compatible with all the RENEWABLES ENGINEERING INC circuit breakers mentioned in the Accessories and Replacement Parts section. Current IQ Gateway is the platform for total energy management for comprehensive.remote s:«ae�a� bl X-IQ-AM1-240-5-HDK I0 Gateway printed circuit board _ es X-10-AM1-240-5C-HDK maintenance,and management of the Enphase Energy System r X-I0-AM1-240-5 80 A busbar with support for one 10 Gateway breaker and four 20 A breakers for Engineering Busbar installing IQ Series Microinverters and IQ Battery 5P X-IQ-AMl-240-SC CURRENT RENEWABLES ENGINEERING INC. IQ Gateway breaker Circuit breaker.2-pole.10 A/15 A 3600 Lime Email: P,Bkig 2 Ririang s, r 92501 Email:ProjedsLIDcreng.solar Production CT Pre-wired revenue P revenue-grade solid-core CT,accurate u to±0.5% Weosite www creng.co 9 PHONE. 951)-204-5492 QCombiner 5/5C Consumption CT Two consumption metering clamp CTs.shipped with the box,accurate up to±2.5% CONTRACTOR INFO Smart 10 Battery CT One battery metering clamp CT,shipped with the box.accurate up to±2.5% The 10 Combiner 5/5C consolidates interconnection equipment into a single enclosure and Includes 10 Gateway for Control board for wired communication with IQ System Controller 3/313 and the streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, communication and control CTRL board 10 Batte 5P 19 pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control ry ••— Ila — communication and is compatible with IQ System Controller 3/3G (CELLMODEM-M1-06-SP-05).only Enphase Mobile Connect(only with IQ Combiner SC)and IQ Battery 5P. Includes Enphase Mobile Connect 4G-based LTE-Mt cellular modem(CELLMODEM-Ml-O6-SP-05)with a 5-year T-Mobile data plan CZ SYS� The IQ Combiner 5/5C,IQ Series Microinverters.IQ System Controller 3/3G.and with 10 Combiner 5C IQ Battery 5P provide a complete grid-agnostic Enphase Energy System. Supports flexible networking:Wi-Fi. Accessories kit Spare control headers for the COMMS-KIT-2 board ELEMENT ENERGY LLC. Ethernet.Or cellular r INCLUDED, ORDER 7470 SOUND AVENUE,MATrrTUCK, NEW YORK,11952 Provides production metering 7993 CELLMODEM-Mt-06-SP-05 4G-based LTE-Ml cellular modem with a 5-year T-Mobile data plan PH:(631)779 s.co Licence--ME-52689 (revenue grade)and Consumption servicesE-589 monitoring CELLMODEM-Ml-06-AT-05 4G-based LTE-Ml cellular modem with a 5-year AT&T data plan (MASTER ELECTRICIAN) Licence-HI-67461 Supports Eaton BR2XX,Siemens Q2XX,and GE/ABB THOL21XX Series circuit breakers (SUFFOLK HOME IMPROVEMENT) Easy to install Circuit breakers(off-the-shelf) (XX represents 10.15,20,30.40.50.or 60).Also supports Eaton BR220B,BR230B,and Mounts to one stud with centered BR240B circuit breakers compatible with the hold-down kit. STEVE STATHOUDAKIS IQ Series Microinverters IQ System Controller 3/3G brackets BRK-10A-2-24OV,BRK-15A-2-240V.BRK-20A-2P-24OV,BRK-15A-2P-24OV-B,and The high-powered smart grid-ready IQ Series Provides microgrid interconnection device Circuit breakers(provided by Enphase) 280 THE SHORT LN,EAST Microinverters(106.IQ7,and 108 Series) (MID)functionality by automatically detecting Supports bottom.back.and side BRK 20A 2P-240V-B(more details in the"Accessories"section) conduit entries MARION,NY 11939 simplify the installation process. grid failures and seamlessly transitioning XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C the home energy system from grid power to Supports up to four 2-pole branch AHJ TOWN OF SOUTHOLD backup power. circuits for 240 VAC plug-in breakers XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board(PCB)for IQ Combiner 5/5C (not included) Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws).Not X-IQ-NA-HD-125A UTILITY PSEG LONG ISLAND 80 A total PV branch circuits required for X-IQ-AMl-240-5-HDK/X-IQ-AM1-240-5C-HDK. er.. Factory installed hold-down kit XA-COMMS2-PCBA-5 Replacement COMMS-KIT-2 printed circuit board(PCB)for IQ Combiner 5/5C PV SUMMARY SYSTEM SIZE STC 425 X 35: 4.875 Bluetooth-based Wi-Fi provisioning ELECTRICAL SPECIFICATIONS (KWDC) for easy Wit-Fi setup PTC 398.1 JX1351= 3.934 Rating 80 A SYSTEM SIZE(KWAC) 1110 @240 Reliable System voltage and frequency 120/240 VAC or 120/208 VAC,60 Hz MODULES 35 11NKO SOLAR 1KM425N-54HL4-B IQ Battery 5P IQ Load Controller Durable NRTL-certified NEMA type 314 Busbar rating 125 A MICROINVERTER 35 ENPHASE Fully integrated AC battery system.Includes Helps prioritize essential appliances during a enclosure IQSMC-72-M-US six field-replaceable I08D-BAT Microinverters. grid outage to optimize energy consumption Fault current rating 10 kAIC and prolong battery life. 5-year limited warranty 2-year labor reimbursement program Maximum continuous current rating(input from PV/storage) 64 A — coverage included for IQ Combiner EnphaseU MN Branch circuits(solar and/or storage)SKUs' Up to four 2-pole Eaton BR.Siemens 0.or GE/ABB THQL Series distributed generation (DG)breakers only(not included) N0M UL1741 Listed Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IO Gateway breaker included Rev Description Dete 0 INITIAL DESIGN 2/28/2025 IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included A 5-year limited warranty Production metering CT 200 A solid core pre-installed and wired to IQ Gateway B •For country-specific warranty information,see the https://enphase.com/in3tallers/resources/warrarrty page. PROJECT u NA A plug-and-play Indushlal-grade cell modem fct systems of up to 60 mlcroinvertws.Available in the United States,Canada,Mezlco.Puerto Rico.and the US virgin Islands,where there Is adequate DATE DRAWN O 2024 Enpheas Enrgy.All rights reserved.Enphase than and CC logos.IQ and certain other marks listed at cellular service r.the installation area. 2I28I2025 httpa://enphaee.com/trademark-usaoe-ouboines aretradrnarks o1 Enphase Energy.Inc.in the U.S.and other coumnes. DRAWN BY E.R Data atbpot to dnngw IOC-5-5C-DSH-00007-6.0-EN-US-2024-09-30 IOC-5-SC-DSM-00007-6.0-EN-US-2024-09-30 SHEET# PV-72 TITLE COMBINER SPEC /Ar IRONRIDGE XR Rail® Family XR Rail ° Family The XR Rail",Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR RaP2 to match. Solar Is Not Always Sunny Over their lifetime. solar panels experience countless THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN extreme weather events. Not just the worst storms in years, ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT but the worst storms In 40 years- High Winds Capable of PRIOR ENEWABLESVVRITTEN ENGINEEAL RING CURRENT ripping panels from a roof, and snowfalls weighing RENEWABLES ENGINEERING INC enough to buckle a panel frame. ."�,� "--.�...i..,,,, "-------...,,,,,, Current XR RailsR1 are the structural backbone 0`�r XR10 XR100 XR1000En ineerinpreventing these results.They resist uplift, �,_ Engineering protect against buckling and safely XR10 is a sleek.low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among and efficiently transfer loads into the rail.designed for regions with light or mounting rail.it supports a range of solar mounting rails Its built to handle CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 building structure.Their superior no snow.It achieves spans up to 6 feet. wind and snow conditions,while also extreme climates and spans up to 12 Email Projects@creng.solar ` while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. Webslte -creng oo spanning capability requires fewer PHONE. 951)-204-5492 roof attachments, reducing the _ 6'spanningcapability 10'spanningcapability 12'spanningcapabiliry number of roof penetrations ,� Moderate load capability Heavy load capability Extreme bad capability CONTRACTOR INFO t Clear&black anodized finish Clear&black anodized finish Clear anodized finish and the amount of fi Internal splices available Internal splices available Internal splices available installation time. ,tf tis 0 rol Rail Selection E2SYS8 The table below was prepared in compliance with applicable engineering codes and standards.` Values are ELEMENT ENERGY LLC. based on the following criteria:ASCE 7-16. Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof 7470 SOUND AVENUE,MATTITUCK, j NEW YORK,11952 F! Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. PH:(631)7797993 services@e2sys.com Licence-ME-52689 • •'-■ -, [ Licence-(MASTER ELECTRICIAN) Licen HI-67461 (SUFFOLK HOME IMPROVEMENT) Snow(PSF) Wind 'low 11111W. TOW NWW STEVE STATHOUDAKIS Force-Stabilizing Curve 90 Sloped roofs generate both Vertical and lateral 120 280 THE SHORT EAST forces on mounting rails which can cause them to MARION, NY 11939 Nonebend and twist.The curved shape of XR Rails is specially designed to increase sirengtn in bow I 140 XR70 XR100 XR1000 AHJ TOWN of SouTHotD directions while resisting the twisting.This unique 160 feature ensures greater security during extreme ``^_•.- UTILITY PSEG LONG ISLAND weather and a longer system lifetime. r" 90 PV SUMMARY 120 I SYSTEM SIZE STC 425 X 35 =14 875 20 (KWDC) PTC 398.1 X 35 =13.934 140 SYSTEM SIZE(KWAC) 1120 @240 160 MODULES 35 JIN KO SOLAR J KM425N-54HL4-B 90 MICROINVERTER 35 ENPHASE QS MC-72-M-U S 30 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90�� ' XR Rails`are IronRidge°offers All XR Rails are made of 6000-series 40 compatible with a range of tilt leg aluminum alloy.then protected with an 160 FlastiFoW and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing §:%* 80 160 Rev Description Date attachments. applications. a more attractive appearance. 0 INITIAL DESIGN 2/28/2025 _ 120 160 A 'Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. B PROJECT# NA 0�2023 tronnidge,Inc.All rights reserved.Visit wittriti.ironridge.com or call-® r ,��_ DATE DRAWN 2/28/2025 DRAWN ABY E SHEET# PV-7 3 TITLE RA I L SPEC IRONRIDGE QuickMountQ ® Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home. solar attachments • j/.'��� PR SE TEECTION BY USE SU W�RE ECTTO RODUCCTIONCOPYRIGHT A must be dependable for the lifetime of the rooftop. ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT • \\6j -- - ' PRIOR WRITTEN APPROVAL FROM CURRENT Due to recent innovations, many asphalt shingles RENEWABLES ENGINEERING INC. have bonded courses.A mount that protects without x the need to pry shingles can really speed things up. • 0V��l Current Halo UltraGrip'(HUG') is here to respect the roof.Its Halo is a cast-aluminum barrier that encases the Engineering UltraGrip. our industrial-grade.foam-and-mastic CURRENT RENEWABLES ENGINEERING INC. seal.This allows HUG to accelerate the installation 3600 Lime Street.Bldg 2 Riverside,CA 92501 process and provide the utmost in waterproofing Email rolects cre ng so ar Hit the rafter? - Welosite vrxw.creng4-5 protection. Give your roof a HUG. .co •• ••• • • • • • •- - PHONE: 951 20492 When you find • Only 2 RD Stir uctural Screws are needed. rafter is found,install 3rcl and final screw. secure six screws to deck mount ft. CONTRACTOR INFO Multi tiered Waterproofing LlJ�y J HUG'Utilizes a multi-tiered stack of aor components to provide revolutionary Trusted Strength 8c Less Hassle waterproofing protection.The Halo cast- CG SYSv aluminum raised-pen meter foundation surrounds the UltraGrip base—a foam- Structural capacities of HUG` were reviewed in led mastic seal combination that many load directions, with racking rail running ELEMENT ENERGY LLC. prevents water intrusion by adher ng 7470 SOUND AVENUE,MATTITUCK, r and seating with the shingle surface cross-slope or up-slope in relation to roof pitch. NEW YORK.11952 PH.(631)779 7993 services@e2sys.com _ For further details. see the HUG certification Licence-ME-52669 (MASTER ELECTRICIAN) _._.. letters for attaching to rafters and decking. Licence-HI-67461 - ... (SUFFOLK HOME IMPROVEMENT) :y --- IronRidge designed the HUG, in combination UltraGrip'Seat Technology r with the RD Structural Screw to streamline STEVE STATHOUDAKIS HUG UltraGrip utilizes a state-of-the- installs, which means the following: 280 THE SHORT LN, EAST art seal design that uses a unique. . MARI ON,NY 11939 foam-and-mastic combination.The foam-backed adhesive provides an No prying shingles AHJ TOWN OF SOUTHOLD entirely new flashing system that No roof nail interference conforms and adheres to every nook 2SYear Warranty and cranny of composition shingles. Product guaranteed free No pilot holes necessary UTILITY PSEG LONG ISLAND filling gaps and shingle step-downs of impairing defects. No sealant(in most cases) PV SUMMARY (up to 1/8"in height). j' No butyl shims needed SYSTEM SIZE (KWDC) STC 425 X 35 =14.875 PTC 398.1 1 X 135 1=113.934 AttachmentStructur _r Seal UL ' SYSTEM SIZE 11 20 C240 (KWAC) Loading • • MODULES 35 PNKO SOLAR 1KM425N-54HL4-B Al �# MICROINVERTER 35 IQ8MC572-M-US Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG'to the roof rafters.the roof HUG has been and certified for I the UL 441 Section UL 2703 mechanical • • deck,or both with our custom-engineered ---+ --i� - RD(rafter-or-deck)Structural Screw The RD tested and rated to compliance with 27"Rain Test"and and bonding 0%. Triple Rated&Certified Structural Screw anchors HUG to the roof ( ) q Rev Description Date to Respect the Roof support 1004 (Ibs) of the International TAS 100 A 95 requirements. See Pe with an EPDM sealing washer,completing UL 2703.441(27) the stack of waterproofing barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual o INITIALDESIGN zrzsaoz5 Intertek TAS 100(A)-g5 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. I for more info. A B PROJECT# NA • DATE DRAWN 2/28/2025 2023 IronRidge.Inc.All rights reserved.Visit�.ir-partentsxom for patent information.Version 1 DRAWN BY E.R SHEET# PV-T4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. 28357 Industrial Blvd. /mil ' I RON RI DGE Hayward,CA 94545 Hayward,CA 94545 1-800-227-9523 I R O N R I D G E 1-800-227-9523 IronRidge.com IronRidge.com Attn:Corey Geiger,COO, IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following: Date:September 7".2021 Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1, The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table t 5 1. THESE DRAWINGS ARE SUBJECT To COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT 2 Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B(for Risk Category II)and applicable state&local PRIOR WRITTEN APPROVAL FROM CURRENT This letter addresses the structural performance and code compliance of IronRid e s Flush Mount System. The count /cit amendments to the IBC. No special wind topographic features are included and both topographic RENEWABLES ENGINEERING INC p P 9 Y Y Y P contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a coefficient(K�,)and wind ground elevation factor(Ke)are taken as 1 0 proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape Current orientation and set parallel to the underlying roof surface. PV modules are supported b extruded aluminum XR Rails 3. Snow load used in the span tables is the ground snow and shall conform to ASCE specified Fig.now and r- P Y g PP y applicable state&local countyicity amendments to the IBC. If the local jurisdiction specified snow load is in the ,f?1 and secured to the rails with IronRidge mounting clamps The XR Rails are side mounted to a selected roof format of a flat roof snow.. it shall first be converted to a ground snow following the local building code/ �! attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables. No special snow conditions are considered that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting.sliding.retention,or ponding snow. No rain-on-snow surcharge load is CURRENT RENEWABLES ENGINEERING INC. considered.The span tables do not a to buildings which are intentional) kept below freezin kept just asoo Lime Stril eet ojec z Riverside.solar szso, components are shown in Exhibit EX-0015. P PP Y 9 Y p 9 P 1 EmWebsee le- reng eO above freezing,or unheated. PHONE t951l-204-5492 The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being CONTRACTOR INFO listed below.for the load conditions and configurations tabulated in the attached span tables. (a)For ground snow no greater than 42psf:Ss s 2 Og for Site Class A, B,C.&D. • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:SS S 1.0g for Site Class A.B,C. &D. • 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:SS S 1.5g for Site Class A,B,C.&D. • 2020 Building Code of New York State(BCNYS-2020.Published in November 2019) EZ SYS' • 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized Into three groups in • Report Aluminum (Structural Engineer Association of California)PV2 2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCP). Roof zones comprising each group along ELEMENT ENERGY LLC. with each roof zones size and location are depicted in Figures 2 and 3 below each span table. 7470 SOUND AVENUE MATNTUCK, NEW YORK,11952 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point.shall P":(63u e2s s 93 co The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 9 p services@ersys com the respective loads and configurations listed,covering wind exposure categories B, C.&D. roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load (MASTER ELECTRICIAN) ASCE 7-16 for gable&hip roof profiles.and roof slopes of 8`to 45-.The tabulated spans are applicable when the &configuration condition from the span tables,or 36" Licence- IMPROVEMENT) (SUFFOLK HOME IMPROVEMENT) following conditions are met: 7 Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. STEVE STATHOUDAKIS 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment fastener). 8 No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: 280 THE SHORT LN, EAST MARION, NY 11939 a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans.or the outer 2,3 of end spans. 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system). Spans are calculated b) BOSS Splice can be installed at any location within a span. AHJ rowN or sour"oLo based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If urlury PSEG LONG ISLAND 3. The underlying roof slope,measured between the roof surface and horizontal plane.is 80 to 450. such conditions are encountered contact support@ironridge com- PV SUMMARY SYSTEM SIZE STC 425 X 35 =14.875 (KWDC) 11 4 The mean roof height,defined as the average of the roof eave height and the roof ridge height measured Prc 3981 JX13s =13 934 from grade.does not exceed 30 feet. SYSTEM SIZE 1120 @240 MODULES 35 1IN KO SOLAR 1KM425N-54HL4-B 5. A clearance from the underside of the array to the roof surface of 2'minimum shall be provided and the ENPHASE height of the array..the distance from the module top surface to the roof surface(defined as h2),shall not MICROINVERTER 35 IQ81MC-72-M-US exceed 10". 6. Module length and area shall not exceed the maximum values listed on the respective span tables. 7 All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Rev Description Date Mount Installation Manual and other applicable standards for the general roof construction practice. 0 INITIAL DESIGN 2/28/2025 A B C 2021 IronRidge Inc. NY Flush Mount System Certification Letter-1 G 2021 IronRidge,Inc NY Flush Mount System Certification Letter-2 PROJECT# NA DATE DRAWN 2/28/2025 DRAWN BY E.R SHEET# PV 5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward.CA 94545 Hayward,CA 94545 RONRIDGE 1-800-ge.co23 IRONRIDGE IronRi geco23 IronRidge.com IronRidge com 10. Systems using I module clamps shall be installed with the following guidance: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67.5°, CAMO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater. Such consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting THESE DRAWINGS ARE SUBJECT TO COPYRIGHT scenarios are shown by asterisks in the applicable span tables. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the PROTECTION BY US LAW REPRODUCTION IN aforementioned system components in regards to the applied or resultant loads of an chosen array configuration. ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT b) CAMO will function within a modules design load ratings. Be sure the specific module being used with Y p g pp Y Y g PRIOR WRITTEN APPROVAL FROM CURRENT CAMO meets the dimensional requirements shown in the figure below and that the module selected is RENEwABLEs ENGINEERING INC suitable for the environmental conditions of a particular project. ��- NEy�,` Sincerely, p NG XU o 2021 .09.07 Current Glens/Ceah P 15:45: 1 oln ' ► w� .��, Engineering uF, � CURRENT RENEWABLES ENGINEERING INC. OQF579 �� 3600 L�Email Projects@creog soar 92501 �ESE10N� Website — creng co Fame Ccmpatib3tY - PHONE (951)-204-5492 X=1.2-22mm Y=15-40mm CONTRACTOR INFO Gang Xuan, PE - y - Senior Structural Engineer Figure 1.CAMO Module Frame Dimensional Requirements CZSYS8 Span values for Exposed and Edge module conditions,as defined below,are included in the attached span ELEMENT ENERGY LLC. tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge 7470 SOUND AVENUE,MAT[TUCK, modules shall be the lesser of the followingtwo: 1 The span value for the Exposed or Edge module condition: H:(31)77 11952 ( ) p p g PH:(631)779 7993 (2)The span value determined by site wind speed and ground snow load.Additionally,irrespective of the lesser services@ersys com span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage Licence- (MASTER ELECTRICIAN) N) limitation detailed in note 9 of page 2 shall apply to the respective condition. Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 1. Exposed Module conditions: STEVE STATHOUDAKIS 280 THE SHORT LN, EAST A module Is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free MARION, NY 11939 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge, rake,or AHJ TOWN OF SOUTHOLD hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from Its free edge to any other adjacent array or panel is greater than 4 feet. UTILITY PSEG LONG ISLAND The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed SYSTEPV SUMMARY Modules. KWDCM SIZE STC 425 X 35 =14 875 PTC 398.1 IX1351=113 934 SYSTEM SIZE(KWAC) 11.20 @240 2. Edge Module conditions: MODULES 35 JINKO SOLAR J KM425N-54H L4-B A module is defined as an Edge Module when its distance from an side of the module to its facing MICROINVERTER 35 ENPHASE 9 Y 9 IoaMc-72-M-us perimeter roof edge(such as eave,ridge,rake,or hip)is less than 2 times the height of the array(2h2) where h2 is measured from the roof surface to the top surface of the module The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Additionally,if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered for this span adjustment. Rev Description Date 0 INITIAL DESIGN 2/28/2025 [DRAWN 2C21 IronRidge.Inc NY Flush Mount System Certification Letter-3 ®2021 IronRidge.Inc. NY Flush Mount System Certification Letter-4 NA 2/28/2025 E.R PV-7.6 TITLE CERTIFICATION