Loading...
HomeMy WebLinkAbout51202-Z �o�, oF sours°�o Town of Southold * * P.O. Box 1179 �oN 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45962 Date: 02/07/2025 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 11900 Oregon Rd Cutchogue, NY 11935 See/Block/Lot: 83.-3-5.3 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 07/15/2024 Pursuant to which Building Permit No. 51202 and dated: 09/19/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: :4 Existing commercial storage building (building 2) converted to self-storage units as applied for. The certificate is issued to: 11900 Oregon Rd LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51202 1/24/2025 PLUMBERS CERTIFICATION: Au h rize Signature ��af sorry° TOWN OF SOUTHOLD BUILDING DEPARTMENT ' a TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51202 Date: 09/19/2024. Permission is hereby granted to: 11900 Oregon Rd LLC 11900 Oregon Rd Cutchogue, NY 11935 To: (Building 2) - Construct interior alterations to an existing commercial storage building to create self-storage units as applied for. Premises Located at: 11900 Oregon Rd, Cutchogue, NY 11935 SCTM#83.-3-5.3 Pursuant to application dated 07/15/2024 and approved by the Building Inspector. To expire on 03/21/2026. Contractors: Required Inspections: DRAINAGE, FOOTING/REBAR, FOUNDATION 1ST, FOUNDATION 2ND, FRAMING/STRAPPING, PLUMBING, ELECTRICAL-ROUGH, FIRE RESISTANT PENETRATION, ELECTRICAL-FINAL, INSULATION, FIRESAFETY INSPECTION, FIRE RESISTANT CONSTRUCTION, FINAL, Fees: Commercial-Alteration $4,740.00 CO Commercial $100.00 Total $4,840.00 _ V o�b Building Inspector OF SO!/j�Ql � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: 11900 Oregon Rd LLC Address: 11900 Oregon Rd City: Cutchogue St: NY Zip: 11935 Building Permit#: 51202 Section: 83 Block: 3 Lot: 5.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GJS Electric License No: 4839ME SITE DETAILS Office Use Only Indoor Basement r Service Solar (— Outdoor rv-1 1st Floor Pool F Spa r Renovation W 2nd Floor Hot Tub r Generator I� Survey (� Attic r Garage rl Battery Storage r INVENTORY Service 1 ph (✓ Heat Duplec Recpt 8 Ceiling Fixtures 17 Bath Exhaust Fan Service 3 ph F Hot Water GFCI Recpt 2 Wall Fixtures 1 Smoke Detectors Main Panel 200A A/C Condenser 2 Single Recpt Recessed Fixtures CO Detectors 8 Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe 8 Heat Detectors 5 Disconnect Switches 7 4'LED Exit Fixtures 16 Other Equipment: 200A Panel 40 Circuit/23 Used, Dehumidifier Notes: Renovation of Storage Unit Inspector Signature: X Date: January 24, 2025 Sean Devlin Electrical Inspector sean.devlina-town.southold.nv.us 119000reg onStorageBldg2 OF SOUIyOIo �l 2-0 2, coo Op c 0/� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1.8.02J, INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND I ]ANSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] 'FIRE RESISTANT PENETRATION [ ] ELECTRICAL.(ROUGH) /Nz ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �'�-u�-- cr l DATE I 'INSPECTOR Of SO(/lyO� -- # # TOWN OF SOUTHOLD BUILDING DEPT. o�m N 631-765-1802 � 1 I NSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] -ROUGH PLBG. [. ] FOUNDATION 2ND . [ rF�INAL ULATION/CAULKINGFRAMING /STRAPPING [ (0W . � [ ] FIREPLACE & CHIMNEY [ FIRE.SAFETY INSPECTION. [ ] FIRE RESISTANT CONSTRUCTION [ - ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) - j ] -ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O. [ ] RENTAL REMARKS: (1) �AWOAA Cft4_) C j DATE INSPECTOR , # �# TOWN OF SOUTHOLD BUILDING DEP t ECEOVE `MUM, 631-765-1802 H JAN 3 9 2025 INSPECTION Building Department Town of Southold [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE i INSPECTOR zs 0 - BUILDING#2 MAC POWER SUPPLY BATTERY CALCULATIONS SITE NAMe::STONEWALl.BiDRACE INSTALLATION: ALLSTAR ELECTRONIC$YSTEM9INC. IACpT1ON:H9W OREGONROAO MONITORING 96fKARSNtC7OS7REEi t CNJCXOGtJ$Ny1f01S SERVICE ,8ONEtlfANiffT18 801�47{+2BBB N�C,V�owI rISI,, Ry 6Y�ebWcm i �NAC Po f El ambl -..�rF y' e" Output Voltage Maximum Avalable Currant Maximum Availabl NAC Current P C muit Meeimum Available Curta t per Aux Oulpul W b Site -� 24VOC B.OA 2.5A 1A T_ _ h os/Avviw.eXmmx.mm/orotlucts/A�COL OA __ _ -- } ouentiry _——_-— Lcaa per Device.Steno-ey _ _—_ Load per Dance Alarm—___--.Taal Device Load:Stall-By Total Device Load:Alarm 1 00m _ 0.115A 0.09A 0.171A ---- -- --- ------ ------ DaVIErr7ypa t a f DeWoe Name —_—_— Ouamity-----Load Per Device.St-d By _--- I aad per Devlc.Alarm- -_ Taal Device Load:Stall-By Total Device Load:Alarm NotlRud AppII F }Ec,+i.SYSTEM SENSOR WS KRL B OA 0.1m CA 1.298A -----—---- SSpAUIL7Batbry 6ackad hP d"�'C '�fif Dinfic.Name _ J puaMiry Load p D Wce:St-d By L-d per Device:Al— Total Device L d:Startl-By Total Dame Load:Alarm _i_ Aux11a1aryO a'^wwp`y,,. gS SYSTEM SENSOR CARBON MONOXIDE DET.CO1224 5 002A 016A OAA OAA — _— __ Tea ystem Lnad I S T S _ r�,;. stand-by 0.19A _ _ 2.271A +,� a°K' "•,•,�,{ �} �� i-..—_— Battery Capacity Requited Stand-by Time Alarm Time Stand-by Battery Capacity Alarm Battery Capacity Minimum Battery Capacity 24 H 5 Min 4.56AH 0.19AH 15JAH a j 1: F FB - 3 2025 U 1r' Note 1:You are fully responsible for verifying these calculations. Note 2:Use the dropdowns and the yellow cells to enter values. SITE NAME:STONEWALL STORAGE INSTALLATION: ALLSTAR ELECTRONIC SYSTEMS INO..., - . �- „ ..�, ,tea".; •'r;';.''+'' MONITORING 861 KARSHICK STREET LOCATION: 11900 OREGON ROAD SERVICE BOHEMIA NY 11716 CUTCHOGUE,NY 11935 631-474-2896 ®FIMUTeALarmS by Honeywell ES-20OX Battery Calculation Secondary Power Source Requirements StandbySecondary Device Type Qty Current Draw Total Qty I Current Draw Total Main Circuit Board 1 x 0.141000 = 0.141000 1 x 0.257000 = 0.257000 IPOTS-COM Communicator 1 x 0.040000 = 0.040000 1 x 0.041000 = 0.04100 PWRMOD24 0! :- x 0.007000 = 0 x 0.008000 = 4XTMF _0 x 0.005000 = 0 x "0 0P1;1,000: ECC-FFT 0. x 0.120000 = 0 x 0.230000 = CELL-MOD-FL/CELL-CAB 0 x 0.055000 = 0 x 0.100000 = ANN-BUS Devices ANN-80(-W) 1,; x 0.015000 = 0.015000 1 x 0.040000 = 0.040000 ANN-100 0 x 0.020000 = 0 x 0.025000 = ANN-LED 0 ' x 0.028000 = 0 x 0.068000 = ANN-RLED 't:r_Q;„,i:j� x 0.028000 = 0 x 0.068000 = ANWRLY ;;'°;0 r? x 0.015000 = 0 X 0.075000 = ANN-1/0 eK:._ X 0.035000 = 0 x 0.200000 = ANN-S/PG y 0 x 0.045000 = 0 x 0.045000 = Addressable Devices BEAM355 0 x 0.002000 = B =EAM355S 0: x 0 002000 D S 365C0 0 x 0.002000 00 000 SD - 355C0 - 0 x 0.0 00300 fig CP355 =0 x 0.000300 SD355 0 x 0.000300 - ''r'-IiE����r€€�:;€::;:¢: i:iiiiiiiiiiii i:1: €:€;:: �€€g:g'•; : EEiieieie c SD365 _40 x 0.000300 0.012000 ,�i;i; i;i;ii; o i;i;i;i;i;i;i;i�:;i;i;•.'-- �ii;'r:i; 'r'•.'- i ;i; '•.'��� i SD355T 0 x 0.000300 = € €I iii;iiii'=•=•:@iiiiiiiiiiiisiliiis€€@; iii:ii@'-i ii€lii: iiiiisl ': iiiiii:iii iii: i iiiii SD365T _ 0 x 0.000200 = € =€i€:�€ =€€iis:;ii: €: €: €:::�i� H =355 0 x 0.000300 H365 =1 T x 0.00 2 000 0.0340 0 0 H3 5HT - _5 �0 x 0.000300 H365HT =0 x 0.000200 H35OR =0 x 0 000300 ::Y:;?isisi�iiii'i:i'i'i'i'i'i'iii'i'i'i' :ii'i:e':•-::•.:::::::::::::::: :: ::::: iiiiii:ii :E:isisii:isisisisi:i;iei:iiie;iiiiipiii:ipiiiii' �i'i'i'i'ipipi•i'i'i:i:i:°:?:?:i: H355R 0 x 0.000300 = iciii is€€€•rilil€iiili ii€iiiii iie;i€ 1llilii Ilii i€iiii€ H365R -0 x 0.000200 = iii����ii€@€iiiiil'.�����€����i€1EliiiiilFll@i€��€lil'sis;'s;€;;'•:���:i:i:��i�':1i;i1i1 D =350RPL 0 x 0.000300 iiiiiiiiiiiiiiiiiiiiiiiiiiiiii�: i:i•.'•:i:i:;?g:�i ii is is � is i:Gi•,'.��:::::: D355PL 0 _ x 0.000300 = €�€i >>is'::i€ii; i€i€@€i€€isi€ I€i€iii€ °iii'-€ i€=€€ i€'='•. i '•i'• MMF-3 0 =0 0 - x 0.000375 M - - _MF 300 10 0 x 0.003500 MDF- _300 0. x 0 000950 MMF-301 =8 x 0.00035 0 0.002800 MMF-302 =0 x 0.000270 MMF-302-6 =0 x 0. 2 0 0000 BG-12LX 27 . x 0.000375 = 0.010125 ii iiiiiiii iiiiiiiiiiii iii i;i1i;:;i; •e';•e';'e';•e,•iii i CMF-300 0 x 0.000390 = 'si'silil €'•€ €€ € € € €€ €`•€`•€ € CMF-300-6 _0 x 0.002250 CRF-300 - _2 x 0.0 2 00 55 0.000510 i3i'•r:: 'si�ii'si-li1i1 €ll��� � ;i€€€ ; @@ Fire-Lite Alarms Page 1 1/31/25 is i ad .9 f CRF-300-6 = :.:.:.:. :.:•:.o-o-o-.o-o-o-::.::.:; :o-:.: : :: :::: rr <E:i i .�jj `fir ?. . _ _5 0 x 0.001450 i - iiio 9�iii;i;i;i o i:iiiii•.' iiiiiiiiiiiiiiiiiiipi: iiiii o o ;;;; � ;;:i:io r, .v.. CDRM-300 0 x 0.001300 € 1300 0 x 0.000400 = ,.;,. ISO-6 0 x 27 -' .0 0 0 00 j;, 65 1 BH-2 - 0 - 10 0 00 - B - _501 BHT 2 0. x 0.001000 B224RB =0 x 00 5 0 0 00 B224BI =0 XI 0.000450 W- _ GATE 0 x 24 0.0 000 Maximum alarm draw for all Addressable devices----------- --> 0.400000 EOLR-1 1 0 IxI 0.020000 =1 lxl0.020000 1=1 FCPS Remote Sync . g':.... ii ili i..... ... iii ii€I i 0­ x 0.021700 = . . . Resettable Power 4-Wire Smoke Detectors 1 0'- 1XI 0.000000_ =1 1 0 1XI, 0..000000 = Auxiliary Power CMF-300(Aux.Power) 0,- x 0.001700 = 0 x 0.007000 = CMF-300-6(Aux.Power) 0 - x 0.008000 = 0 x 0.020000 = MMF-302(Aux.Power) `0 . x 0.012000 = 0 x 0.090000 = MMF-302-6 Aux.Power 0-- x 0.050000 = 0 x 0.270000 - B200SR Aux.Power 0 x 0.000500 = 0 x 0.035000 = B200SR-LF Aux.Power 0. x 0.001000 = 0 x 0.125000 = SWIFT Wireless W-GATE 1 "0 IxI 0.040000 1=1 0 IxI 0.040000 1=1 Miscellaneous Devices STARLINK CELL RADIO 1 _ x 0.071000 = 0.071000 1 x - 0.200000 = 0.200000 0.- x 0.020000 = 0 x 0.040000 = 0 - x 0.000000 ' = 0 x 0.000000 = `0 x -0.000000 = 0 x 0.000000 = 0'= x 0.000000. 0 x!- 0:000000 = Output Circuits NAC/Out ut#1 0.000000 = € is i 0.622000 = 0.622000 NAC/Out ut#2 0.000000 = i'i': 'i i;i'i' 0.000000 = NAC/Out ut#3 i€€ 0.000000 = € iii ii€. 0.000000 = NAC/Out ut#4 €€i i:i'i i:i 0.000000 0.000000 = FCPS(remote Sync) 0 Ix 0.000000 = 0 x 0.021700 = ii•.ii•.iii iiiaii'•ii '• `. iii'• i'•i'••.'•i'i e Current Draw from T133 ei;ii;ii : 0.000000 . = iii ::. °0.000000° _ Total Standby Load 0.295835 Total Alarm Load 1.560000 FIMUTeALWMS by Honeywell ES-20OX Battery Calculation Calculation in Total Sheet 24 Hours. Standby Load Current 0.29584 Amps x 24 1=1 7.100 AH . • 5 Minutes. Alarm Load Current(Amps) 1.56000 Amps x 0.084 = 0.131 AH Total Current Load 7.231 AH Multiply by the Derating Factor 1.2 = x 1.20 Total Ampere Hours Required 8.68 AH Recommended Batteries: BAT-12120-12AH Batteries Fire-Lite Alarms Page 2 1/31/25 t FEB - 3 2025 k t Battery Check The batteries can be charged by the ES-20OX Charger. The batteries can be housed in the ES-20OX Cabinet. Current Draw Check NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit. ES-20OX Control Panel: The output current is within the panel's limitations. - FllmuTeMarm by Honeywell ES-20OX Circuit Detail NAC/Output#1 Device Qty Non-Alarm Draw Total Qty Alarm Draw Totall SRL 15 2 x 0.000000 = 0.000000 2 x 0.043000 = 0.086000 P2RL 110 2 x 0.000000 = 0.000000 2 x 0.162000 = 0.324000 P2RK110 1 x 0.000000 = 0.000000 1 x 0.212000 = 0.212000 0 x 0.000000 = 0 x 0.000000_ _ 0_ x 0.000000 = 0 x 0.000000 = 0 x 0.000000_ = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0. x 0.000000-- = 0 Ix - 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.622000 NAC/Output#2 Device Qty Non-Alarm Draw Total Qty Alarm Draw Total 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.0000M _ 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000, _ 0 x 0.000000 = 0 XU 0.000000 = 0 x 0.000000. = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.0.00000 = 0 x _. 0.000000 0 Ix 0.000000 = 0 x -0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.000000 NAC/Output#3 Device Qty Non-Alarm Draw Total Qty Alarm Draw Total 0 x 0.000000. = 0 x 0.000000 = 0 x - 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000. _ 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x _ 0.000000 - 0 x 0.000000.. _ 0 x 0,000000_-- = 0 x _ 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.000000 Fire-Lite Alarms Page 3 1/31/25 NAC/Output#4 Device e Qty Alarm Draw Total -0 x 0.000000 = 0 x .0.000000 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x -0.000000 = 0 x 0.000000 = 0 x 0.000000 - = 0 x - 0.000000 = L0 - x '0.000000 = 0 x 0.000000 = 0 x 0.000000, = 0 x 0.000000 = 0 x 0.000000 - = 0 x 0.000000 = 0 x .0.000000 = 0 x 0.000000 = 0 X1 0.000000 " _ _ 0 x 0.000000 = Total Standby Load 0.000000 1 Total Alarm Load 0.000000 I" FEB 3 Fire-Lite Alarms Page 4 1/31/25 DAA . . DiGiovanni and Associates Architects 26 preston avenue sea cliff,ny 11579 (516)671-3624 email DAA93@msn.com January 30,2025 Town of Southold Building Department 54375 Main Road Southold,NY 11971 Re: Stonewall Storage—Building#2 (1 story—11,880 sf) Permit 51202 11900 Oregon Rd Cutchogue,NY 1000-083-03-005.3 To whom it may concern; Please be advised that to the best of my knowledge and belief,the above referenced interior alteration was built.per the Town of Southold approved plans. The 3 hour fire walls are in compliance with the approved plans,NYS 2020 building codes, and with ASHRAE 90.1. Contact me with any questions Resp\ ARo QtvQ\�p..DIGjO 2 Z N;A`4� r8i 69 �- 'Davi aia TOSouthold Building 2-1.3025 LL-� IELD INSPECTION REPORT DATE COMMENTS 'n • V �Fo FOUNDATION (1ST) — - --- ©3 --- =� FOUNDATION (2ND) z ^'o G Q c ROUGH FRAMING& Q PLUMBING 1 _ W r r� INSULATION PER N.Y. STATE ENERGY CODE lAAVN % r'-N. ' r FINAL n ADDITIONAL COMMENTS h �O �z x d - - r b • DAA DiGiovanni and Associates Architects 26 preston avenue sea cliff, ny 11679 (516)671-3624 email DAA93@msn.com March 3, 2025 Town of Southold Building Department 54375 Main Road Southold,NY 11.971 attn: Tracy Dwyer Re:. Stonewall Storage—Buildings 1 & 2 11900 Oregon Rd Cutchogue,NY 1000-083-03-005.3 Tracy, Please be advised that the 3000 sf storage areas on buildings 1 and 2 will be used for the storage of non-combustible items only. These areas are separated from the rest of the building by a 3-hour fire walls. Contact me with any questions Respectfully, �•�'� to � � �r a I: U 01 David DiGiovanni, RA,.aia TOSouthold Building I &2 1 >o�s�►Fu�,��aG TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownn.gov 1,�. 2• Date Received APPLICATION FOR BUILDING PERMIT `� For Office Use Only D ECEIVE PERMIT NO. 5120` Building Inspector: JUL 15 2024 kApplications and forms must�e fdletl out�n their entirety ;Incomplete i� Building Department appllcat�ons i�tlt not be acce`ptetl Where�the Applicant is notthe;owner,an Town of Southold owner's Author�zat�on form(Page 21 shal[be co�rnpleted >^ r ,` u `" ` Date:7/8/2024 Name: 11goo Oregon Road_LLC —q _ SCTM#1000-083-03-0053 Project Address: 11 goo OregonRd. Cutchogue, NY 11935 Phone#.631-734-2166 Email:martyk@unit2gocom Mailing Address: 11 goo Oregon wRd. Cutchogue, NY 11935 r.F f.4 S, ¢ t. ,-..3'_ .,.�: j !w aL 3,.:}. a �1<i., .,t.Y ,�.- .s i >Y•)ts - ae"; . ",.k Name:Martin Kosmynkav n w Mailing Address: 11goo Oregon Rd. Cutchogue, NY 11935 Phone#:631-384-9979 Email:martyk@unit2go.com DESIGN MOFESSIQNAkINFQRMATION ...> ., i + x. Name:DiGiovanni and Associates Architects Mailing Address:26 Preston Ave. Sea Cliff, NY 11579 Phone#:516-671-3624 Email:daa93 m msn.co r@ CONTRACTaR INFORMATION �� �., ,.., _.._t ,r . Name:Martin Kosmy_nka Mailing Address: 11 goo Oregon Rd *Cutchogue, NY 11935 Phone#:631 734-2166 Email:martyk@unit2go.com DESCRIPTIONOF`PROPO$ED CONSTRUCTION- � �' �`�' � "` '' � f = h ❑New Structure ❑Addition DAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Interior walls $300,000 Will the lot be re-graded? ❑Yes ©No Will excess fill be removed from premises? ❑Yes ONo 1 7 Existing use of property:Warehouse storage Intended use of property:Warehouse Storage Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to L� this property? ❑{Yes RNo IF YES, PROVIDE A COPY. S F t k' > 1 9 ` B Check Box After Reading FThe owrierjcontractor/design profess pl t "►s responsible fbr all drainage and stormivater issues as rovided bar �Chapter 23fi of the Town;Code APPLICATyION iS HEREBY MADE to the Bwldmg Department for fhe•�ssuance'of a Budding Permit pursuant to the Building Zone Ordinance ofthe Town of 5outholtl,Suffotk County,New York and other,appltcable Laws,Ordinances or Regulationsrfor the construction o bmldtngs addat�ons;alteratwns4o�forremoal or demolition as herein described "The applicant agrees to comply with`all applicable laws;ordinances,builtlng code housing code and regulations and'to admit authoraed mspecfors onrpremises'ard in builtling(s)for necgssary:mspect�ons Fatse statements made herein are punishable as a`ClassA misdemeanor pursuant to Section 210'45 of the New York State Penal Law x, , Application Submitted By(print name): ❑Authorized Agent El Owner Signature of Applicant �� R Date STATE OF NEW YORK) SS: COUNTY OF 9tU-��bA_ ) wbl Vl �05 IV1UV h being duly sworn, deposes and says that(s)he is the applicant (Name of individual sig�ninng contract)above named, (S)heisthe �/Iol,'Y1c&_ (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me\this day of l ln\U. , 20 'ANtry Public EVE L.GATZ-SCHWAMBORN NOTARY P1:BLIC.STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION Registration No.OIGA6274028 Qualified in Suffolk County qJ I (Where the applicant is not the owner) Commission Expires Dec.24,20.Qg I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 p ���d� D`oAUG _ 20AUIL DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD 0 1 BAD lall Annex- 54375 Main Road - PO Box 1179 'y TOWN.�)F S�OI'�outhold, New York 11971-0959 Telephone (631.) 765-1802 - FAX (631) 765-9502 rogerr(aD,southoldtownny.gov-� seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: E �a Company Name: 0-y- L� c� 2 ( L C-, Name: Gra rL4 So [i c 2 License No.: q 93� M t_ email: r @ G V,,64 Phone No: b,3 153c5- [request an email copy of Certificate of Compliance Address.: Pd. fed*I"f-uL-k I 5: JOB SITE INFORMATION (All Information Required) Name: I I n I E a &o i ra 2- Address: I 19 00 Re.q Q Cross Street: L Phone No.: Bldg.Permit#:_ 51 apq email: Tax Map District: 1000 Section: Q$ Block: Lot: 005, 3 BRIEF IPTION OF WORK (Pleas Cl rly) QJO—mP ` W, sewteSL .i Chi That Apply: Is job ready for inspection?: ❑YES ❑NO ❑Rough In ''rr ❑Final J Do you need a Temp Certificate?: 'YES ❑NO Issued On f70 I�Sge4 HIS-1 Temp Information: (All information required) Service Size W 1 Ph ❑3 Ph Size: c CO A #Meters_ Old Meter# ['New Sery Service ❑ Service Reconnect L?Underground ❑Overhead ,# Underground Laterals ❑l 02 [:AH Frame❑Pole Work done on Service? ❑Y Additional Information: PAYMENT DUE WITH APPLICATION Vv 1 o Electrical Inspection Form 2020.xlsx G c� l� BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD ® ! `�� Town Hall Annex-54375 Main Road-PO Box 1179-Southold, NY 11971-0959 , �a®t Telephone (631) 765-1802 ^Q1.Ll. Temporary Certificate # I .7 Lf�-- Date �— 2024 Customer Name q60 0re a-Y, 12d 6tC Electrician Name ('ec-+YIL Address //600 oa k, 44 C-W1_ho Phone 631 �JqR — L{ 5YS e-mail e-mail Qr e N7Ct v,, CC1rb-, Phone I License# Ll 0-3 Cl /t j _... Size f A Phase ` Overhead Underground #of Meters Remarks #of Underground Laterals 1 2 New "H" Frame or Pole H P Fire Reconnect Was work done on Service? Y N Flood Reconnect Old Meter# Service Reconnected Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this installation is complete,the town will conduct a premises inspection of the service equipment. This verification is valid for 90 d om the date above. Authorized by `'� �y4gUFFDC,��,P AUG _ R 20AUIL4 aDEPARTMENT-ElectricalInspector TOWN OF SOUTHOLD y z , DIN6GbTpypll Annex- 54375 Main Road - PO Box 1179 DUEL TO INN. 80 01-Southold, New York 11971-0959 y�jo�l► �,ao�� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cD-southoldtownny aov- sea nd(c)southoldtownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: 6- 6�-I e c+n2 L L.L, Name: I a rL4 Sa (I cp License No.: q�3 t�- email: r Phone No: 63(a CIE- 5 5- EO(request an email copy of Certificate of Compliance Address.: JOB SITE INFORMATION (AllInformation Required) c� Name: c, M i n t S4v r G eq 9- Address: + ®t) RJ e Cross Street: Phone No.: Bldg.Permit#:` _ 51 oZOa email: Tax Map District: 1000 Section: Q S Block: Lot: 00 5, 3 BRIEF IPTION OF WORK (Pleas CI rly) aJZ amp 4W, S2-r✓off n�VO4�n Ch That Apply: Is job ready for inspection?: DYES ONO ❑Rough In ❑Final Do you need a Temp Certificate?: WYES ONO Issued On 170 issLlPcl 91S-/Zy Temp Information: (All information required) Service Size W I Ph 03 Ph Size: aCo A #Meters _ Old Meter# L'New Service ❑ Service Reconnect L?Underground ❑Overhead # Underground Laterals 01 02 [AH Frame❑Pole Work done on Service? ❑Y Additional Information: PAYMENT DUE WITH APPLICATION Q7�Electrical Inspection Form 2020.x1sx1�� PERMIT# Address: Switches Outlets r ' GFI s � v Surface I Sconces2- 1 HH's ( { r i � UC Lts Fridge HW POOL % Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. I` Water Bond Carb 1U Micro GrbDis Lights Heat Pucks ERV HOT TUB/SPA Inst Hots DeHum Transfer Disc Combo Cooktop Minisplit - Blower AC �` AH Hood Blower 9 Service Amps gjCo Have ��1sed �� , Sub Amps Have Used CC Comments hti l ram , LRECEI\jSITE PLAN USE DETERMINATION W0Initial Determination own o1� oard Un � 1 w Date: 2-Lo 2 Date Sent:�2� 2-1 ry fD i C kelp� Project Name: )q 0� Orea r, Roma LAC, - Project Address 11°IOQ___ �YPf�IQ(1 (�(h�� �LITf �1AQ d J I 1 Suffolk County Tax Map No.: l000-93 - -5-3 Zoning District-. L A Request: Co n ye r l_ hU I lcl 1 a -• ,a-Prn m +oy-j,04 -- 5r-W s+orn a — i A n i4-- 0 (Note:Copy of Building Permit Application and supporting documentation as to proposed use or uses should be submitted.) wily Initial Determination as to whether use is permitted: P 5 ( I Initial Determination as to whether site plan is required: y e�J C Y1Qfln P� s 1a 6-30-0,020 2YWLAIA- Slin—aturee of ding Inspector -------------------------------------------------------------- Planning Department(P.D.)Referral: P.D.Date Received: / / ` Date of Comment: Comments: M c Sid a ' 2 CO _I Signature of Planning6ept.Staff Reviewer Final Determination Date: Decision: D L RD,D V Signature of Building Inspector DD SEP 1 1 K24 TOWN c��} OPJ A Y1®Y Road APPROVED AS NOTED B•P# 5' COMPLY WITH ALL CODES OF DATE'- FEE�.�c_ WOO m- NEW YO STATE�TOWN CODES A ED AND CONDITIONS OF NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPf=CTIONS: FOUNDATION,TWO REQUIRED FOR POUREQ CQ.NCRETE ROUGH-FRAMING&PLUMBING swmwc INSULATION SC1� FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL. ATE. NOT RESPONS113LE FOR DESIGN RK TOR CONSTRUCTION ERRORS INSPECTION REQUIRED Additional Certification May Be Required, Fire separation required as per, NYS Code ," All exterior righting installed,replaced or repaired shalt conform to Chapter 172 of the Town Code i A [3 D A^ 013 11 DiGiovanni & Associates ,OX LAND Architects 10 gym° m 26 preston avenue Q' ¢gym LAND N/F OF NORTH FORK RECYCLING INC. sea cliff, ny 11579 (516) 671 - 3624 LAND N/F OF JEANNE M. GRACE /000-083-03-004.7 a 1000-005 03-0045 (COMMERCIAL 51TE-WELL wATER) (COMMERCIAL SITE) as msn.com 0� n p. m° Q 4�°OI'00 E 337 86 x x x x x b' FENCE x 5 4 x 50' E x x x x x x x x 4�3.Iq' x x LL O x xb'GRAIN LINK FENCE p Z 24-Ilo g RBB R Is \�� q �hr N x x x x x x A� LL f �� O P DIG S 0� i dJ 6'PVC x FENCE—� LL 0 \ U u. x x x x r Q \ �Z x x 4'GHAIX LINK FNG. 3 _ FROJEGT LOGATIO \ \ LL 4 v GATE LL v x Q' U� ,� w w 3 HOUR FIRE WALL \ \ N ux I Q LOCATION(TYP for, x u Z J \ 9j 8169 �- ILL 0 W LU N 7 LL V w C" � I EXISTING ;p � � 6 v WATER 5ERVIG p IgB.OG' Ig8.00' / IUANDEANKE6 N \ W m m J ? x Y Jt, h° F EXISTING U O x BUILDING I -I- --1 // \ 15 51J E D BUILDING 2 a Q�� m I STORY p Eo�ME v N EXISTING I STORY _ I ISTOW / �� 11\4v �h �� F.F.EL.66.3 x 0 5TORAGE BUILDING p EX STING I \ / ¢ II 550 sF o SELF STORAGE BUILDING ot�� .b' I6.0' x GATE x 4'C.L.F. �x �° OGG G 5-I Const Glass 5b I 11,880 sf I po p OGG Gp 5-I, Gonst Glass 5b L J p <oN r GONG.WALK IL (dry building) Ff el = 57.5 SLATE in 1.9 PATIO EX oR �� �� `& filed under separate application dry building Ff el = 57.5 O ry x � .O'tt1 FRAME 6.6' 3 OFFICE ' 'I\` ENCLOSE v 6.F.EL.60.9 IV— m° PATIO j x x 30.3' - - 5�51-1011 \ k \G "O W W ONG. F oR/�F v WATER SERVICE WALK a , \\ \ x \ PROP, \ \ ` KEYPA �— _ \ \ SIGN ; ® x 160.00, 200.00, 3 i ANTE NK� II SPACES // / \ ?�r Q 0 0, Qo y o - BUILDING 4 F ASPHALT DRIVEWAY -i O BUILDING 3 x rn EXISTING I STORY � � '���,� AU N �°ro EXISTING I STORY SELF 5TORAGE BUILDING + /� \ QQ(��P ¢ o SELF STORAGE BUILDING o 12,000 sf I / \'\ \ \ / 0 `b'k Ql o OQ u� 7 z.o ® PROP. O q,600 sf o OGG G 5-I, Gonst Glass 2b I 0 v KEYPAD OGG op 5-1, Gonst Glass 2lb p / 3 PROP. POST d RAIL FENCE x (dry building) fF el = 57.5 L , \ \ \ Q*�gmb ° x x x x >< x . x x x x (d buildin ) fF el = 57.5 / Q O �(wQ Q�ry° GATE %� ��I filed under separate application filed under separate application LAN17)5GAPE �"3 Q AREA I \ 3 �? h• i 0 1 3 LANDBANKED 200.00, \ Q / BllILDING 5 BUILDING 6 1 1 // o V) � J°3 EXISTING I STORY EXISTING I STORY + —J \ \ / �� mry ° UJ i m SCREEN PLANTIN65 SELF 5TORAOE BUILDING o SELF STORAGE BUILDING " �p \ 12,000 sF o I2,000 5F Na h - o OGG G 5-I, Corsi; Glass 2b / x w Occ Gp 5-I, Gonst Glass 2b p \ / Q03n N 4 °03' O" 255.52' PROP. 6' FENCE oo % v (dry building) ff el = 57.5 (dry building) ff el = 57.5 L J n \ LL f oo LL I I a Filed under separate application filed under separate application BLOCK RET.WALL \ Z w \ \ \ Z I/\ Q h�ry L�a CONCRETE � ATO EARN POT ` \\ / LANO NIP OF WJF FARMS LLG LIU w x \\ \ \ (COMMERCIAL 5/TE) _ \ z 1P LANDBAN ED SPACES x Xx xx X x x x x x pZUv 6' FEN pjvyW ad00 af00 N 46003'00" IN 560.8q' , GRAVEL DRIVE SITE PLAN R E V 15 I O N S THESE PLANS ARE AN IN5TRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT.INFRIN6EMENT5 WILL BE PROSECUTED. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS AND SHALL BE RESPONSIBLE FOR FIELD FIT AND QUANTITY OF WORK.NO ALLOWANCE SHALL BE MADE GENERAL NOTES \/ FIRE CAULK CONT (TYP EACH ON THE BEHALF OF THE CONTRACTOR FOR ANY ERROR OR METAL ROOFING 51DE NEGLECT ON HI5 PART. I. Contractor shall verify all dimensions and conditions in Field and report any discrepancies to Architect before commencing PANELS 6"20 GA TRACK W/2" 2. All construction and materials to be in accordance with New York State B FLANGE uilding Code and all local codes and GOXS LANE regulations 6"20 GA METAL STUDS ® I6" Stonewall 3. All electrical work shall comply With New York Board of Fire Underwriters requirements. Electrical contractor,shall submit O/c MULBERRY ST. q certificate From above agency. 2 ROW5 b" I6 5A METAL 4. These Plans comply with 2020 New York State Energy Conservation Construction Code EL 12'-0" TRACK with 3" FLANGE Q Storage Ric5. Contractor shall verify location of all utility lines, and report to architect any condition not consistent With drawings b"20 DA METAL STUDS a 16" Q 6. Drawings are not to be scaled, use dimensions only. Each contractor shall be held responsible For his work, and o/c 2 FROJEGT LOG?�TION discrepancies shall be called to the architects attention. I 0 Q 7. Plans, details, and elevations shown indicate intent and ualit� level. Provide all Supports,bridging, blockin BD (� p q 9 pp , and 3 LAYERS J" TYPE X GYP g - ALTERNATE HORIZON and TUTHILL w 11900 Oregon Road connections as re uired q VERT. STAGSER JOINTS TAPE O 5. Electrical Contractor to File as required in order to obtain approval inspection and sign off's from the,local jurisdiction For all required work — and SPACKLE BETWEEN Q p Cutehot7ue , NY 9. Fire Alarm Contractor to File as required in order to obtain approval, inspection ons sign off From the local jurisdiction For all required work LAYERS 0 p g 10. Contractor to obtain all permits for construction and obtain all required inspections and sign-off's as required by local FIRE CAULK CONT (TYP EACH �p authorities 6"20 5A TRACK W/2" SIDE Z 0 E Y MAP 11. All Footings to be on undisturbed soil (2 ton Min) and shall be 4000 lb. concrete FLANGE z < Oty DRIVMERGE S I �� PLAN � y� I� 12. All slabs on grade to be or.2 ton min. soil (typical) SLAB nts 13. Contractor should submit Certificates of Insurance's prior to commencement of any work (Liability, workmen's compensation,builders risk and fire insurance). 14. Doors to have commercial grade levered hardware as manufactured by 5chlage D series Sparta design uon. DEPOT LANE 15. Security cameras to be selected under separate contract (NIC). FIRE NALL SECTION 1/12/24 A-2 nts DATE A=00 orb� A5 NOTED SCALE 1 OF 3 DRAWN BY CHECKED BY dd DAA EXI5TINO TO REMAIN FROF05ED INTERIOR ALTERATION ik DiGiovanni & ,qb_o Associates Architects 3 HR RATED FIRE WALL SMOKE TIGHT JOINT 6" METAL STUDS @ 16" 0/G @ WALL d ROOF (TYP ALL W/(3) LAYERS 5/5" TYPE "X" GYP. BD FIRE WALL JUNCTIONS) EXISTING 20'-0" x I4'-0"h DOOR EACH SIDE (TYPICAL) EXI TING 20'-O" x 14'-0"h DOOR 26 preston avenue PINNED SHUT REMOVE OPERATOR , 4 UL DESIGN #U435 PINNED SHUT REMOVE OPERATOR - Sea CII ny 11579 0 and ALL HARDWARE and ILL HARDWARE �(516) 671 - 3624 _ _ _ 0 �aa93@msn.com EXISTING ELECTRIC OPERATED ROLL UP DOOR 2 III I I " - MEGH - - I I i I _ I I O I O I - O O O - I O O !tN-110 _ = 5ELF STORAGE SELF STORAGE _ = ELF 5TORAOE = 5ELF STORAGE 5�e ,, f ��REq `��• EX LT 0 _� OI 3a-- OI OI OI --' O 2,110 sF/300=1p 2,Ig5 sF/300=1P r — — 2,145 0/300=1p r — — 2250 sf/300=Sp 6p CLIMATE CONTROLLED CLIMATE CONTROLLED CLIMATE CONTROLLED CLIMATE CONTROLLED \R4r', r-+ Q W 50-0 - a o12 = �, EXISTING 3 HR RATED FIRE WALL O O O III O _ O I O O O1 O I O O cy O I O o O O �o"81gg P,� UL DESIGN # U435 2„ l _ _ I - - - ,•I , - - - _ , NEW`iC ": I I I I O O I ISSUED LP In Ln 10 STORAGE AREA - — O _ i O - i -' — O O — — — — — — 5,000 5F/ 500=6p = _ I I - � 1Z 1Z UNHEATED I � I O -' O � I - ,1 11 „ , O o �I W — — � I - - - - QI aI - aI — — - aI OLn o1 0l of O O of = QI QI _, � QI _, - - - - - - > I 0 0 Q NOTE: Q I Q I Q I Q LOCATE WOOD TRUSSES --- — — — I — -- - - — — -- - — - — - - EACH SIDE OF FIRE WALLS (TYP - VIF) I _ I I I I I I I I I i I I I I I �-j - - -, - - - - -� O O- O L — EX LT O O L - - -, - - - - -, O �- - - - - - - - -, O , EX�T - EX LT w W _ _ -'EX LT_ EX T O LT - EX T ---- — LT � � � - L' (D ! r5O„JEX ! � ! O_ O_ „ I ,_ I , 0, 8p 2 a EXISTING ELECTRIC OPERATED ROLL UP DOOR 4� - - 5_O - MEGH I O EXISTING 20'-0" x 14'-O"h DOOR 3 HR RATED FIRE WALL EXI5TING 20'-0" x I '-0"h DOOR 5 EXISTING 20'-0" x 14'-O"h OOR �5 PINNED SHUT REMOVE OPERATOR b" METAL STUDS @ 16" 0/G PINNED SHUT REMOVE OPERATOR PINNED SHUT REMOVE OPERATOR and ALL HARDWARE W/(5) LAYERS 5/5" TYPE "X" and ALL HARDWARE and ALL HARDWARE PER NY5 2020 BUILDING CODE TABLE 1006.2.1 SMOKE TIGHT JOINT 5PAGE5 WITH I EXIT @ WALL d ROOF (TYP ALL FIRE GYP. 51 EACH SIDE (TYP) 5 OCCUPANCY UN5PRINKLERED WALL JUNCTIONS) UL DESIGN U435 2q MAX OCCUPANTS and 100' MAX TRAVEL DISTANCE • 5 PERSONS MAX and 64'-b" MAX TRAVEL Iq5'-0" DISTANCE - COMPLIES EXISTING METAL SIDING NOTE: NOTE: (TYP ALL EXTERIOR WALLS) AT NO TIME WILL THERE BE MORE THAN ALL INTERIOR PARTITIONS TYPE I LON (TYP) 2q PERSONS IN ANY FIRE AREA/SPACE ALL EXTERIOR WALLS TYPE 4 (TYP) FLOOR PLAN t-2 BllILDIN05-2 Val, O O It S G H E U L L 12 TAG DOOR 51ZE THK D 0 0 R FRAME SADDLE HDWR STOP RATING REMARKS 4 �4 TYPE MAT L DOOR 1 3'-5" x 1'-0" --- B MTL --- -- I INTERIOR ROLL UP .2 5' S" x T-O" -- B MTL. --- -- I INTERIOR ROLL-UP q/13/24 PER To SOUTHOLD COMMENTS 3 V-0" x "1'-O" --- B MTL --- -- I INTERIOR ROLL UP &/1&/14 per FIELD V151T 4 EXISTING --- G --- -- TO PLATE 5 3'-6" x 1'-0" 1 3/4" A HIM HM ALUM. 2 INSULATED METAL PROVIDE (LOSER EL +20'-0" REVISION S THESE PLANS ARE AN IN5TRLKNT OF SERVICE AND ARE THE Type I - Interior roll up - 22 gauge corrugated galvanized Steel with slide lock, padlock provisions and two lift FULL HT 3 HOUR RATED EXISTING METAL PANEL GLG and X15TING WOOD TRU55E5 TYP) PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE handles. Polypropylene wear strip, 15 gauge galvanized guides, 12 gauge Support brackets and spring tensioner with WALL BEYOND (TYP) BLOWN IN INSULATION (R-35 - TYP) PR05ECUTED. extruded aluminum bottom bar and weatherstripping. (color o5 Selected)) WNTRACTOR SHALL VERIFY ALL FIELD CONDITION5 AND Type 2 - Provide levered locking hardware - inside always unlocked. O DIMENSIONS AND SHALL BE RESPONSIBLE FOR FIELD FIT AND QUANTITY OF WORK.NO ALLOWANCE SHALL BE MADE m ON THE BEHALF OF THE CONTRACTOR FOR ANY ERROR OR SMOKE TIGH' JOINT @ FIRE WALL NEW (2) LAYERS OF 6" R-11 BURGLAR BARS @ 5" O/C (TYP NEGLECT ON HI5 PART. WALL AND ROOF JUNCTION (TYP) METAL PANELS ON ACOUSTIC TILE CEILING IN METAL FRAMING (TYP) (R-35 TOTAL) GATT INSULATION fmm TO PARTITION PANELS TO SUSPENSION SYSTEM (TYP @ (TYP) CEILING) r )rly--,) CORRIDORS ONLY) Stonewall O METAL PANELS ON METAL _ 30" X TEMPERED STUDS with BATT INSUL (TYP Storage llc GLA55 @ EXTERIOR WALLSVISION PANEL 11900 Oregon Road TYPE A TYPE B TYPE c Cutcho ue NY o ° g ' 0 r PAIN'ED METAL PANELS 3 " METAL STUDS @ 16" o% O O O FLOOR PLAN ON GALV. METAL 5TUD5 6 METAL STUDS @ 16 EXISTING METAL 510INO on WOOD W/5/8 TYPE X GYP BD EACH TO let FLOOR O/C W/ 3 LAYERS OF 5/5" PURLIN5 with SPRAY FOAM SCHEDULES SEGTI ON � I SIDE: ONLY (FINISH SIDE and METAL PANELS UNIT DATUM TYPE 'X" GYP. BD. EACH 51PE i, CORRIDOR SIDE) TO 5'-6° 51DE TO 10'-0" AFF PROVIDE PROVIDE GALVALUM PANELS INSULATION - PROVIDE 2 � EL. +0'-0" METAL STUD GLG @ 16" o/c METAL STUD with R-15 BATT PROVIDE BURGLAR BARS TO q'-O" AFF (TYP) GRADE i u nINSULATION >I /../ .. i / �/ / / / •� •/ • / / / •/ andMETALLINE \ \/\ \ \ / q O off WITH TYPXGYP ,/ / / / .. / / /. \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \/\/\/\/\/\/\ \/\/\ \ \ \ \i\�\i\i\i\i\i\i\�\i\r\i\/\i\/\/\/\/ / /\i / / / / / / / / / / / / / / / / / / / / / / / . @ 5 O.G. TO METAL DECK ( a / / /. / ..:. / / , \ \ \ \ \ \ \�. \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\\\\ \\\\\\\\\\\\\\\\\\\\\\\\\\ \ \ \ \ \\\\\ \ \ \ \ •.. \ . \ \ �, r AO 00 PANELS TO 10 O off � \ \ \ . � = \ \ / r / / r / / , / / / / r / r / / / / / / r / / / / / / / / r / //i/i //i/i //i/i/i //i ////// ,, .. �, BD ,/ / / / .... / / /. \ \ \ \ \ \ \/\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \r\/\/\/\/\/\/\/\/\/\/\/\/\r\/\r\/\/\r\/\r\r\/\/\/\/\ \ / / / / ABO�/E @ 10-0 off) //////, //..._ ///j.\\\\\\\\\\\\\\�. \ \ \ \ \\\\\\\\\\\\\\\ \ \ \ \ \\\ \ \\\ \\\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ .. \ ,\\\\\\. \ \ \ \ \//.//,//.//.//,//.//./,,//.////,////.////✓/,/�//,//,////.//////,//,//,/i,//.//,//.//.//.//.//,//,//.///,//,//.//✓/.//.//✓///,//,//.//.//,////i /i /i.//i././ //i/i/i/i/i/i/i/i/i/i/i/i/i/i/i/i/i //// / / / /// / /// / // / / O O 12/24Aall OI 3 HOUR RATED UL DESIGN #U435 \//\\//\\// \/� \ij\\//� %\\j\\� \ I HOUR RATED �i/��/��/� i/� /�\i/� �i\\\/i\\\ \� /\\/i\\/i\\/ D A T E UL DE51ON # �\ii \\/'\��\X�\X��0\�i�� A5 NOTED 2 BJILDINO SECTION �\ \///�\ 5 C A L E I OF 3 A 2 1/4" = 1'-0" DRAWN BY CHECKED BY did DAA 5 N 5 N 2 N H DiGiovanni 12 ° � ° � ° Associates EXISTING METAL STANDING SEAM Architects ROOFING (TYP.) 26 preston avenue sea cliff, ny 11579 (516) 671 - 3624 Daa93@msn.com TO PLATE EL. +20'-O" —4 R 69 L � z NEW O TO 151; FLOOR Ln ® FE] 1 5 5 U E D DATUM EL. +0'-0" NEW INSULATED METAL MAN EXI5TIN5 METAL ROLL UP DOORS E EX15TINO METAL 510IN5 (TYP) DOORS(TYP For E PINNED SHUT REMOVE OPERATOR AND RELATED HARDWARE (TYP 0 5ELF 5TORA6E AREAS). SOUTH ELEVATION A-5 E3IJILDIN5 2 EXISTING TO REMAIN PROPOSED INTERIOR ALTERATION Iq8'-0" 2 x 4 AT( in SUSPENSION 2 x 4 ATG in 5U5PEN51ON 2 x 4 ATG in SUSPENSION 2 x 4 ATG in SUSPENSION SYSTEM ® q'-O" off BY SYSTEM ® q'-O" off BY SYSTEM m q'-O" off BY SYSTEM ® q'-O" off BY ARM5TRON5 or APP'D EO ARM5TRON5 or APP'D EG ARM5TRON5 or APP'D EO ARM5TRON5 or,APP'D EQ (TYP) (TYP) (TYP) (TYP) I � � I L-6 I-b" -6 I b' -b I-b -b I-b '-6" -- - EX LT ❑ ❑ ❑ — ❑ ❑ ❑ _ ❑ ❑ ❑ _ ❑ ❑ El- ----------- - ----- I I I - o in in in j R E V 1 5 1 0 N 5 I THESE PLANS ARE AN I145TRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT.INFRINGEMENT5 WILL BE D. CONTRACTOR SHALL VERIFY ALL FIELD GONDITION5 AND DIMEN5ION5 AND SHALL BE RE5PON51BLE FOR FIELD FIT — — — — - - — — — — — — — — — — - AND QUANTITY OF WORK.NO ALLOWANCE SHALL BE MADE ❑ ❑ -�c .Jc ❑ ❑ Elf ❑ ❑ ❑ F ❑ ❑ ❑ NE THE BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HI5 PART. El Stonewall Storage llc 11900 Oregon Road Iqa'-o" Cutchogue , NY LEGEND 2 REFLECTED GE I L I NC PLAN ❑ RAB RECESSED LED—) x 2 FIXTURE T34FA2X2 ELEVATIONS A-3 GE I L I N(5 PLAN I/8" = I'-O" � RAB REGE55ED LED 2 x 4 FIXTURE T34FA2X4 RAB RE(E55ED LED 2 x 4 EMEROENGY FIXTURE with BATTERY BACK UP T34FA2X4/E 1/12/24 I--0 LED EXIT LIGHT with BATTERY BACK UP D A T EAm;� 00 A5 NOTED 2 2 3 5 6 A L E 3 OF DRAWN BY CHECKED BY dd DAA EXISTING TO REMAIN Nj PROF05ED INTERIOR ALTERATION ik DiGiovanni & Ig8'_O, Associates 36 36-2' 38'-10" Architects 3 HR RATED FIRE WALL b" METAL STUDS @ 16" 0/G W/(3) LAYERS 5/5" TYPE "X" GYP. BD 26 preston avenue EACH 51DE (TYPICAL) HEAT PUMP UL DE51ON #U435 sea cliff, ny 11579 (516) 671 - 3624 Daa93@msn.com 0® i i GO HT GO MEGH �- H/5 5ELF 5TORA6E H/5 SELF STORAGE SELF STORAGE SELF 5TORA6E 24-I10 EXISTING 3 HR RATED FIRE WALL 2,110 sf/300=lp r — 2,Ig5 sf/300=lp H/5 H/5 2,145 sF/300=lp H/5 2,250 sf/300=ap �p,Ep ARcy, F] EX15TIN5 llL DESIGN #ll435 CLIMATE CONTROLLED CLIMATE CONTROLLED CLIMATE CONTROLLED CLIMATE CONTROLLED I I - - - - — I F a z • � I 5 5 I C S II C 5 � C �, �� � _._._ 5 5 1) E D STORAGE AREA -- - I _ i _ i I - - ---- 3,000 sf/500=6 � I I P I I UNHEATED o .. I• III .. I K) I I ' w w w — -- - - - - - w F - - - - - - I I - - - - -- - - — - - — - - - - z z zl zl O <I < QI of of I JI JI I -� I I al QI QI QI — — — — I -- — — — — -- I -- ------- -- -—-—- I ----------- — — — — I — — — — 05 I 5 5 ( C 5 C5 5 5 HT I I I t o i I I i I i I I I i I i I I I I I W- - - G0 q>_ L - -W GO L - - - _CO - -L ( �Ffl 0- ( ❑ H/5 �- I H/5 P❑ HT GO P ME(H R�___'L -a-Ell i � ... n - — n M 0 f 11�3 HR RATED FIRE WALLL/I HEAT PUMP 6" METAL STUDS a 16" 0/0 NOTE: PER NY5 2020 BUILDING CODE TABLE 10062.1 W/(5) LAYERS 5/8" TYPE "X" AT NO TIME WILL THERE BE MORE THAN SPACES WITH I EXIT GYP. BD EACH 51DE (TYP) 21 PERSONS IN ANY FIRE AREA/SPACE 5 OCCUPANCY UN5PRINKLERED UL DE516N #U455 2q MAX OCCUPANTS and IOO' MAX TRAVEL P15TANCE • 5 PERSONS MAX and 64'4" MAX TRAVEL Iq8'-0" DISTANCE - COMPLIES _ EXISTING METAL 51DIN5 (TYP ALL EXTERIOR WALL5) FL -0O I� PLAN COX LANE — — P'-2 BUILDING5 I/8" = I'-O" y e LAID wr or xAw+c/4ORACE L.,w NT o►NdR+ll PORx acru.nrs aaeea�os-a�+s rca•«�Ra *rJT (adhPlRalK SIfE•NlLL FlAfERI r cnr.m uNc reN:e L, i br 5 41°0I'00"E 33T.86 •'Fcxce 5 46°24'50"E 473.Iq' y • •��_ A ' x PROJECT LOGATIO \ S lace FlRE YiV.L \ C'!! LPCATION MP for I) \ t � i �,s. Gay W A R �6 tr M1100' 19b.0a'• 5 I ND / \ X 88 tr V sr* e EUILDING I EUI 1 / I_j / \ y Sh woo m EXI5TING I STORY EXISTING 15T0 l'[L.M! b 5TORA5E BUILDING FIRE ALARM NOTES: ' d x 8p Glass Sb $ SELFGp5TORAGE BUILDING 11,88CJ ei U w+n +•c..r. Occ SgGamtFGlase 5 ® 4. E .°, ti•m GONO"'"L" (.Cldry bNlding)FF al.5T3 ( bullding)FF t •S1.5 \ p•• .�ro e' r�rrLLL�rax Filed underuparate application I. FIRE ALARM AND SMOKE DETECTION SYSTEM SHALL "'" ° `F" \V � erK�eee ersL.eo.+ COMPLY WITH MANUFACTURERS INSTALLATION SPECIFICATIONS. q/13/24 PER To 50UTHOLD COMMENTS LEGEND STATE AND LOCAL BUILDING CODES N.F.P.A. 12 AND ALL �""xM'" " `""LK � o- \ M� REV 1 5 1 0 N 5 A6ENCIE5 HAVIN5 JURISDICTION. PRaP. \ L KEYPA \ / FIRE ALARM AND SMOKE DETECTION SYSTEM , . + `1 60�0 ��� 5� • t' SHALL BE "FIRELITE" OR APPROVED EQUAL, 2. CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUITS. 0 • \ �, �� THE5E PLANS ARE AN IN5TRUMENT OF SERVICE AND ARE THE ZONED AND ALARMED SYSTEM. OUTLET BOXES JUNCTION BOXES, CABINETS, ETC. FOR " "r°""""' B5TINO I6 3 BUIW,I STORY I� / \ ;, "�- EXISTING I STORY EXISTING STORY PROPERTY OF THE ARCHITECT,INFRINGEMENT5 WILL BE �. ,t? S �E' �' SELF STORAGE BUILDING T A COMPLETE OPERATIONAL INSTALLATION. 0 x SELF STORAGE BUILDING I /� \ 12,000 eP r E KF�rn�D gb00 aF Occ 5-I,Gomt Glass�b �\ PR05ECUTED. (� t PROP.POST RAIL FENCE $ Oc by 5-I,Corm Claw 2b $ Gp. (- v /� O x x x x x (dry building)fF el•ST.S Pibddun)der xaraFtelop Sllcatlon \ ,DYMBOL DESCRIPTION MODEL NO. 3. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL ��/ ' g 5ArE Filed underxpaze application p p CONTRACTOR 5HALL VERIFY ALL FIELD CONDITIONS AND FIRE ALARM SYSTEM EQUIPMENT WITH WORK OF Q \ \7a\ DIMEN51ON5 AND SHALL BE RE5PON51BLE FOR FIELD FIT OTHER TRADES PRIOR TO INSTALLATION. �pS _ LANDSCAPE \ AND QUANTITY OF WORK,NO ALLOWANCE SHALL BE MADE FAGP FIRE ALARM CONTROL PANEL ES 200X - FIRE LITE �,� AREA \ \ ON THE BEHALF OF THE CONTRACTOR FOR ANY ERROR OR LOCATED IN DETACHED OFFICE BLDS (ADDRESSABLE) 4. ALL MANUAL PULL STATIONS SHALL BE MOUNTED r NEGLECT ON H15 PART. WITH THE HANDLE 4&" ABOVE FINISHED FLOOR. s A� r ��� - 100 '` 7 ❑F PULL BOX BGI2LX - FIRE LITE _ ¢� � '� -�s�- ` II /,��; d'' BUILDING 5 EUILDIN6 5. ALL VISUAL DEVICES SHALL BE MOUNTED 80 ABOVE 7 s� EXISTING I STORY EXISTING 15TORY (ADDRE55ABLE) �' Y" E°"R"�'"°' Stonewall FINISHED FLOOR OR 6" BELOW FINISHED CEILING �0 SELFST��sBUILDIN6 $ SELF I / \ F u) * * * _* """ Gonet Glass 2b $ Occ 6p 5-I.Corot Glass 2b I / \ WHICHEVER 15 LOWER. y e ? ao N 4 °03' 0" -233.52' PRO►.•'FENCE g (drytvllding)FFa =ss (dry Ilding)fFel V.s s L_/ \ HT 1100 FIXED TEMP. HEAT DETECTOR FIRE LITE 550HT a i Filed under separate appllLatlon Filed under 5eparote appllcat on \ (ADDRE55ABLE) b Storage llc . CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS AND PERMITS PRIOR TO START OF W "D OPCle �ORK AND OBTAIN efi xR L" °L� In o \ H/5 FIRE LITE z \ \ HORN dSTROBE -24VDG 515N-OFF FROM ALL AGENCIES HAVIN5 JURISDICTION � (5Y5TEM SENSOR) UPON COMPLETION. I LANDS D SPPLES C 11900 Oregon Road $ •'FENCE t�o'd 4 00 O SMOKE DETECTOR FIRE LITE 5D365 1. A FACTORY TRAINED TECHNICIAN SHALL 5UPERV15E N 46°03'00'H „K 5606q' Cutchogue , NY (ADDRE55ABLE) THE FINAL CONNECTIONS AND SHALL TEST AND ADJUST ALL EQUIPMENT UPON COMPLETION. GO CARBON MONOXIDE DETECTOR 10 YEAR BATTERY LOCAL ALARM ONLY 5. SYSTEM SHALL BE CENTRAL STATION MONITORED via SITE PLAN FLOOR I$ 51TE CELLULAR RADIO COMMUNICATOR I ❑R HVAG SHUT DOWN FIRELITE M500 q• HVAG 5HUTDOWN OCCURS DURING GENERAL ALARM A-0 1" = 60' COXS LANE (ADDRESSABLE) CONDITION PLANS, 5GHE®ULE5 NIUL6ERRY 5T. 0 � 10. SYSTEM TO BE INSTALL TO COMPLY WITH NFPA �p� 12/2016 and NYS CODES 2020 �_ % PROJECT LOCATION If T LL 8/6/24 ARL R l O F ROAD W 0 DATE �w �0 F =Q °� DRIVMERCE KEY MAP A5 NOTED J nrb S I OF C ALE DEPOT LANE � DRAWN BY CHECKED BY dd DAA DiGiovanni & Associates Architects 26 preston avenue o sea cliff, ny 11579 w tu (516) 671 - 3624 LU W Q Daa93@msn.com m Z o Q BLDG 6 o � Q �ZoJ S)O oN U- Z 24-110Q F r �siREOzQ -1 w wW Rc_ �. p 4 �4 A Oi0 ti% ww REQUIRED FIRE ALARM 5Y5TEM > > z z 5 m BLDG 5 ? SEQUENCE OF OPERATION Q� g o Q Q N < - LL X 5Y5TEM INPUT I MANUAL PULL STATION ® ® ® ® O�NEW YO 2 SMOKE DETECTOR ® ® ® ® s 5 HEAT DETECTOR ® ® ® BLD6 4 4 NOTIFICATION APPLIANCE CIRCUIT SHORT 0 ® ® 15541 E D 5 GROUND FAULT 6 OPEN CIRCUIT 1 LOW BATTERY 8 FAGP POWER FAILURE ® ® BLDG 3 q OTY q OTY 2 OTY 4 OTY Ib OTY l R HT 5 /5 T BUILDING 21 BLDG I LOCATED IN ADJACENT OFFICE BUILDING FAGP FU5E 015CONNECT 5WITCH DIGITAL RADIO — `-00 L20VAG COMMUNICATOR 24V DG BATTERIES FIRE ALARM RISER A- NT5 12 l2 TO PLATE _ FULL HT 3 HOUR RATED EXISTING METAL PANEL GLG X15TIN(5 WOOD TRU55E5 TYP) WALL BEYOND(TYP) LIMITED ACCESS OPEN 5FACE NO STORAGE NO MECHANICAL EQUIPMENT, FORGED AIR,OR DUCTWORK m BURGLAR BAR5 ® 8" O/C SMOKE TIGHT JOINT 0 FIRE WALL NEW (2) LAYER5 OF b" R-Iq (TYP From TO PARTITION WALL AND ROOF JUNCTION (TYP) METAL PANEL5 ON (R-5b TOTAL) GATT IN51)LATION PANELS TO CEILING) TYPICAL DUCTWORK AGOV5TIC TILE CEILING IN METAL FRAMING (TYP) (TYP) LOCATION 51,15PEN51014 5Y5TEM (TYP CORRIDORS ONLY) METAL PANEL5 ON METAL 5TU05 with BATT IN5UL (TYP �y 0 EXTERIOR WALL5 REVISION S THESE PLAN5 ARE AN INSTRUMENT OF SERVICE AND ARE THE � n PROPERTY OF TFE ARCHITECT.INFRM6EhENTS WILL BE OO PROSECUTED. COMRACTOR 5HALL VERIFY ALL FIELD CO VITIONS AND ►U i"A Er505 AND SHALL BE RE5PON5IBLE FOR FIELD FIT v _ v AND QUANTITY OF WORK.NO ALLOWANCE SHALL BE MADE p ON THE BEHALF OF THE CONTRACTOR FOR ANY ERROR OR W v NEGLECT ON H5 PART. TO 15t FLOOR DATUM EL. +0'-0" GRADE ., GRADE Stonewall \ \ \ \ \ \ \ \ \ \ \ \ / \ \ \ \ \ \ \ \ \ \ \ INN" \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ / / r tora Sg 11c 11900 Oregon Road Cutchogue , NY SECTION 2 EVLDINC SECTION RISER, MATRIX 8/21/24 DATE 0 A5 NOTED SCALE 2 OF 2 DRAWN BY CHECKED By dd = = TOWN OF SOUTHOLD,=FIRE:MARSHAL ,. � .. Towri Hall Arinex 54375 Main Road R.O.Box'1179 Southold,NY 1197-1=0959 Telephone(631) 765-1802 Fax(631) 765-9502:his://1aw�v.sauthalato�vluiv:co; I h Po r office Use only rA.UG - 7 2024 -PE RMIT NO. . O — Building Inspector: BUILDING DEPT. :Applications and forms must be"filled:'out in their".entirety.Incomplete Wlv OF SOUTH applications will not be accepted:WORK IS NOT TO BE STARTED prier to the approval of'plans and Issuance of a permit. Rasa building periitit!been-obtained for this project? Yes ❑No If yes,b.uilding:permif# Date:=19/2024 PROJECT INORMATION: . Project Address:119p0 OREGON ROAD SCTM# 1000-083:00-3.00-005.003 Cif':CUTC.HOUGE. Zip:1.1953 CONTACTPERSON INFORMATION: Name:R ICHARD TALBOT Mailing Address:861.KARSH ICK.STREEET, BOHEMIA NY11716. ;Phone#::631-474-2896 Email:BILLING@ALLSTARLI.COM Preferred.contact method'(select.one): DPhone ❑Email =CONTRACTOR INFORMATION: Name:ALLSTAR ELECTRONIC-SYSTEIVIS -Contractor License.#:.12000276275 Mailing.Address:861:KARSHICK SSTREET, BOHEMIA,NY 1171,6 _Phone#:g31-47 -2896 E►nai1:BILLfNG@:ALLSTARLf.COM -SCOPE,OF WORK: Occupancy Descriptio�i: ❑Assembly []'Business ❑Education ❑Factory/Industrial ❑.institutional: ❑Mercantile ❑:Residential ®.Storage Description of Work: ❑:New System: -9 Existing System Modification- Sprinkler/Standpipe'/Water Supply Fire.Alarm/CO Detection-Systems -Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply.) ❑NFPA 13,13D or.I I R System InManual ®Automatic. O Smoke Control ❑Standpip.e ❑ Fire Pump ❑Protected-Premises(local)- ❑ Wet or Dry Chemical[Clean ❑Supervising station: Agent. Nurnber of spdnkler-hF'ads:. 'RCentral.Station ❑ Kitchen;hood/exhaust.- ❑:Other Floor Area(sq.ft.)! W . - 8 ':` E•r q: ,'c+ :,<.'sf:. I,the:undersigned.Understand that the-issuance ofa permit for the type which is herein applied for in based on the agreement to conform totall regulations and requirements.f further understand that non•compliance of said requirements,:by myself or any officer or employee of theArm or Individual listed as the applicant on this form,shall be cause for revocation.of said permit.Upon revocation ofsaid permit the applicant or any employee of the applicant shall be prohibited to conduct such work for-which this permit was issded.The reissuance of a-permit shall be based upon review of the circumstances-leading to the revocation.Any false statements)made herein are punishable as a Class A misdemeanor pursuant .-to Section 210.45:of the,Penal Law Application Submitted By(print name): RICHARD TALBOT DAuthorized Agent L70wner Company.(if applicable):: ALLSTAR.ELECTRONIC SYSTEMS. Applicant Signature- r4-77. Date:-07/19/2024 FIRE PROTECTION SYSTEM PERMIT APPLICATION,SUBMITAL INSTRUCTIONS t. Submit application only after reviewing the requirements.for the specific permit for which you are applying(click the applicable link below). I.ItI" AL-'iRiv1 I(!A1>t40N ;A1 N0 N 11)E 1)1"6 ;t:".I I Q N i -Vk i'a:tt. 61111)1,--1 I N V V.l1{I;SI'.RIiV)<1:E'R N1'4i"t'i P (h4:43:1 t1Cl'.. �1Y't'9t[:9�,i N' I1�44)Ib.4, l °ai9,?�C.S �'iv 11��:q�. 1. 1"E�.t.Ca l-•11'S' FEES A$300'permit fee is required for a non-residential permit.A$100 Certificate.of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the'rown of Southold. Permits,once issued,shall at all times be kept on the premises.designated thereon with a,copy of approved drawings and all related documentation required to,,obtain said.pennit.Installations subject tofnal testing,inspection and approval.Arrangements for. testing inspection shall beimade by contacting the Town of Southold Building Department.(631)765-1802. FOR OFFICE-USE-ONLY Amount Paid:: Check No:: FM: Permit No.:, Date: Exp. Date: I 2' 1 1 UNIQUE ID NUMBER F O.R O F F I-C E USE ONLY • � State of New York Z00027627s. Control �Depai*Wiey.it of Site No. ���:���1-;� DMSION DF LICENSING,SERVICES PUR SUAWT TO THE 'PE DV1SIC��S.":t~41~���IRTICLE 6D .QF ;THE.. . EFFECTIVE DATE GEN91RAi$. -BUSINMERS. LAW AS %T .RELA i�ES TO vSF_. ri ,ci,�Npc� ;• �#�:Im ���� or 149TALLI 'G, �S—ER �Ic,.NGj- oR MAINTA�b I NG SECURITY OR FIRE ALAR SY8T9V18-. r 1 EXPIRATIQN'DATE q TALBOT .R-ICHARa 7 JP ► Y 2 602 WHISKEY RD ( � - 4 .. d 'HAS REF_IIV IDOL.Y : ':�'Eh4SED TC 04GA;GE 'l iq 'rHiE -BuS INESS CF• DWSTALL.IW6'. SEt� VICIhIr3, 0R: P1A1N'rA1f 1f4G S9CURITY 3' .CR. FIRE.:ALARM V GTEPIS to Vft"s Wh01-1.The gopat"w,of.stato has.oausad ! tts.atitcIW seal to bo hateunto atfuied QVAL.IFIER. Tt�t.:t3OT. R.-ICHAPD F.''k . ROBERT %j. I ODRIQUEZ SECRETARY OF' STATE Dos-rasa(aov srot) ...F... ... _ .' M w .,p. , w37R I DF-61011:C H365 Series Addressable Heat Detectors FIM'LITe°ALaCI'Y1S by-Honeywell Addressable Devices The Fire-Lite® Alarms Fy365(A), H365R(A), and H365HT(A) addressable plug-in thermal detectors are designed for both perfor- mance and aesthetics and-are a direct replacement for the H355 Series.A.new modern, sleek, contemporary design and advanced thermal technologies make the H365(A)Series ideal for both system operation and building design. Exclusively for use with Fire-Lite's addressable fire alarm control panels,the H365(A)Series-point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel to quickly locate a 1, - fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor \ / light to provide a local,visible sensor indication. The H365(A) Series includes fixed temperature, rate-of-rise and �, '.•a' ., high heat fixed temperature detectors that provide effective, intelli- gent property protection for;a variety of applications. Detectors are available for both LiteSpeed,TA°and CLIP applications as designated. Features SLC LOOP: OPTIONS: • Two-wire SLC loop connection Remote LED output connection to optional RA10OZ remote LED • Unit uses base for wiring, annunciator ADDRESSING: Installation • Addressable by device . addressing H365 Series plug-in intelligent thermal detectors use a detachable • Rotary,decimal (Refer to the ad Fire-Lite panel manuals for device capacity.) base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. ARCHITECTURE. Mount detector base(all base types)on an electrical backbox which • Designed to meet UL 268.7th Edition is at least 1.5" (3.81 cm) deep. For a chart of compatible junction • Sleek,low-profile,stylish-design boxes,see DF-60059. • State-of-the-art thermistor technology for fast response NOTE:Because of the inherent supervision provided by the SLC loop, • Integral communications-and built-in device-type identification end-of-line resistors are not required. Wiring "T-taps"or branches are permitted for Style 4(Class`B')wiring only. • Built-in tamper resistant feature When using relay or sounder bases, consult the 1300(A) installation • Built-in functional test switch activated by external magnet sheet 156-3626 for device limitations between isolator modules and iso- lator bases. OPERATION: • Fixed temperature model (H365(A)) factory preset to 135°F Applications (57-C) Use thermal detectors for protection.of property. For further informa- • Rate-of-rise model(H365R(A)), 15°F(8.3°C)per minute tion, refer to 156-6525, Applications Manual for System. Smoke • High-temperature model (H365HT(A)) factory preset to 190°F Detectors,which provides detailed information on detector spacing, (88•C) placement,zoning,wiring,and special applications. • 360°-field viewing angle of the two visual alarm indicators, LEDs blink red in Normal condition and turn on steady red in Alarm Construction • LEDs blink every time the unit is polled These detectors are constructed of fire-resistant plastic. The H365 MECHAN/CALS; Series plug-in intelligent thermal detectors are designed to commer- cial standards and offer an attractive appearance. • Sealed against back pressure • SEMS screws for wiring of the separate base Operation • Designed for direct-surface or electrical-box mounting Each H365 Series detector uses one of the panel's addresses(total • Plugs into separate base'for ease of installation and maintenance limit is panel dependent) on the Fire•LiteJC1 Signaling Line Circuit • Separate base allows interchange of photoelectric,ionization and (SLC). It responds to regular polls from the control panel and reports thermal sensors its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an OTHER SYSTEM-FEATURES; alarm. It blinks its LEDs when polled and turns the LEDs on when • Remote test feature from the panel commanded by the panel.The H365 Series offers features and per- • Walk test with address display formance that represent the latest in thermal detector technology. • Low standby current DF-61011:C•11/18/2019—Pagel of 3 Product Line Information B200SA-IV:-Same as B200S-IV, ULC listing NOTE:'-IV"suffix indicates CLIP and LiteSpeed device. B200SCOA-WH: White, Intelligent, programmable sounder base in NOTE:A"suffixindicates Canadian version. English/French (required in Canada for ULC applications with CO Series detector applications H365:White, low-profile intelligent 135°F fixed thermal sensor, Lite- B200SCOA-IV: Ivory Intelligent, programmable sounder base in Speed only English/French (required in Canada for ULC applications with CO H365A:Same as H365 but with ULC listing Series detector applications, ULC listing H3654V:.Ivory, low-profile intelligent 135°F fixed thermal sensor, B200S-LF-WH:-White, Low Frequency,Intelligent, programmable LiteSpeed and CLIP sounder base. Produces a fundamental frequency of 520 Hz +/- H365A-IV:Same as H365-IV but with ULC listing 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653.0238) H36511: White, low-profile intelligent rate-of-rise thermal sensor, LiteSpeed only B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- H365RA:Same as H365R but with ULC listing 10% with a square wave or its equivalent; designed to meet the H365R-IV: Ivory,low-profile'intelligent rate-of-rise fixed thermal sen- NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) sor, LiteSpeed and'CLIP B200SR-WH: White, Intelligent sounder base capable of producing H365RA-IV:Same as H365R-IV but with ULC listing sound output with ANSI Temporal 3 or continuous tone. Intended for H365HT: White, low-profile;intelligent 190°F fixed thermal sensor, retrofit applications.(CSFM:7300-1653:0213) LiteSpeed only B200SR-IV: Ivory, Intelligent sounder base capable of producing H365HTA:Same as H365H'but with ULC listing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications.(CSFM:7300-1653:0213) H365HT-IV: Ivory, low-profile intelligent 190°F thermal sensor, Lite- B200SRA-WH:Same as-B200SR-WH with,ULC listing Speed and.CLIP . H365HTA-IV Same as H365H-IV but with ULC listing B200SRA4V:Same as B200SR-IV in Ivory color,ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- NOTE.For details on intelligent bases,see DF-60059. 10% with a square wave or its equivalent; designed to meet the B300-6:White,6"base,standard flanged low-profile mounting base NFPA 72 sleeping space requirement. Intended for retrofit applica- (CSFM:7300-1653:0109) tions.(CSFM:7300-1653:0238) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable base(CSFM:7300-1653:0109) sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the B300A-6:Same as B300-6,ULC listed NFPA 72 sleeping space requirement. Intended-for retrofit applica- B300A-64V: Ivory,.6" standard flanged low-profile mounting base, tions.(CSFM:7300-1653.0238) ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6,package contains 10 TR300:White, replacement flange for B210LP(A)base B501-WHITE: White; 4" standard European flangeless mounting TR3004V: Ivory",replacement flange for B210LP(A)base base.UL/ULC listed(CSFM;7300-1653:0109) RA100Z(A): Remote LED annunciator.3-32 VDC.Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box.For use with B501(A)and B300-6(A). UUULC listed(CSFM:7300,-1653.0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting base.UUULC listed(CSFM:7300-1653:0109) M02-09-00:Test magnet with telescoping handle B501-WHITE-BP•Bulk pack of B501-WHITE contains 10 CK300:Color Kit(includes cover and trim ring),white, 10-pack B224R6 WH:White,relay base(CSFM:7300-1653:0216) CK3004V:Color Kit(includes cover and trim ring), ivory, 10-pack B224RB-IV: Ivory;relay base(CSFM:-7300-1653:0216) CK300-BL:Color Kit(includes cover and trim ring),black, 10-pack B224RBA-WH:White, relay base, ULC listing B224RBA-IV: Ivory,relay base, ULC listing 6224131-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV: Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White,isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base,.ULC listing B200S-WH:White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable, sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol.(CSFM:7300-1653:0213) B200SA-WH:Same as B20OS-WH,ULC listing Page 2 of 3—DF-61011:C•11i18i M SYSTEM_ SPECIFICATIONS Size:-2.W.(5.3-cm)high; base-determines diameter B300-6:6:1"(15.6 cmpdiameter -B50--1:4"(10:2-cm)diameter For a complete list of detector bases see DF-60983 Shipping weight:3:4 oz.(95 g) Operating temperature range: • H365,H365R Series:-4°F to 100°F(-20°C to 38°C) • H365H Series:-49F to 150-F(-209C to 66-C) -Detector spacing: UL-approved-for 50 ft..(15:24 m).center-to-cen- ter;FM approved for 25 x:25 ft.(7-:62 x-7.62 m)-spacing Relative humidity::10%-93%o non-condensing Thermal ratings:fixed-temperature set point 135OF(57°C),rate-of- -rise detection 15°F(8.3°C)per minute,high temperature heat 190oF (88-C) Mounting: B300-6(A)flanged:base,included See"Product Line Information: Intelligent Bases,"if using a dif- ferent base. ELECTRICAL SPECIFICATIONS voltage range: 15-32 volts DC peak Standby current(max.;avg.):200pA @ 24 VDC(one communica- tion every-5 seconds with LED.enabled) Max current:4.5 mA @ 24:VDC("ON") Listings and Approvals Listings and approvals below apply to the H365.Series detectors. In some cases,certain modules may not be listed by certain-approval agencies;or listing may be- process:Consult factory for.latest list- ing status. • UUULC Listing:.S2517 . • --FM.Approved . • CSFM:7272=0075:0501 LiteSpeedTm is a trademark and,Fire•Lite@ Alarms-is a registered trademark of :Honeywell International.Inc. ©2019 by Honeywell.lntemational Inc.All rights reserved.Unauthorized use of this i document is strictly prohibited. This document is not intended to be used for installation purposes. We.try to keep our product information up-to-date and accurate. IS09001 We cannot cover all specific applications or anticipate all requirements: All specifications are subject to change without notice. M1119aINI8M101 FIICTIIIIN6: QUALITY SYSTEMS for more information,contact Fire•Lite'Alarms.Phone:(800):627-3473,FAX:(877)699=4105. Country of Origin:Mexico www.firelite.com Page 3 of 3=DF-61011:C•11/10/2019 SYSTEM SENSOR Indoor.-Se lectablee Output Horns, t Strobes,' and Horn .Strobes for `4.. Wall Applications System Sensor L-Series audible visible notification t� A Al products are rich with features guaranteed to cut - j F7. 3 installation times and maximize profits with lower ; current draw and modern aesthetics. Features " • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for.Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,standard and compact devices,and plain,FIRE, and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt-operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15;30,75,95, 110, 135,,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate:shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements.using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING @ LISTED Aov"oven S5612 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,300072 `` AVDS865-05•2/22/2018•Page 1 L-Series Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or,double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5,and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn'strobes'shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system: Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at'1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a;coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize.Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair"of wires.The module shall mount to a 411116 x.411/16.x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C). Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 1.6 to 33 V(24 V nominal) Operating Voltage.Range MDL3 Sync Module 8.5 to 17.5 V(1.2.V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge. 12 to 18 AWG Wall-Mount-Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVD8865-05.2/22/2018•Page 2. UL Current Draw Data StrobeUL Max. 8-17.5 Volts 16-33 Volts. 8-17.5 Volts. 16-33 Volts. Candela- DC DC FWR Sound Pattern dB DC - DC FWR Candela 15 88 43 60 Temporal High. 39 44 54 Range. 30. 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal_ High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110, N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209- 3.1 KHz Temporal Low - 29 32 54- 185 -i N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42. 43 54 UL Max.Current Draw(rnA RMS),Wall Horn Strobe,Candela Range(115-185 cd) 8-17.5 Voits 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd, Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 .182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1K'Temporal Low 91 154, 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts - FWR Input 15cd 30cd. 75cd 95cd 110cd . 135cd 185cd Temporal High 83 107 166 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal.High 111 135 185- 207 230 264 316 Non-Temportal:Low 79 104 15.7 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 1 77 102 156 177 199 234 291 Horn Tones and Sound Output Data StrobeHorn and Horn 8-17.5 16-33 Switch Volts. Volts Position .Sound Patjern:. dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5. 3A KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84. :89 89 8 3.1 KHz NonJemporal Low 77- 83 83 9* -Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05.2/22/2018•Page 3 L-Series-Dimensions 1.91° 3A5° 3. mm 88 mm 2 3.57° t551 m 125 3 M mm � 125° 2 mm (9.1 cm) (3.9 cm) 32 mm 0 0� UP o 73? 527° 1i 5.38, 13.9mm 527° (13aj m 0133.9 mmL o � o A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount-Back Box SBBGRL,.SBBGWL. 4.70° (11.94 cm) 4.7° (4.85 cm) 125, 4.82" 1.25" 119 mm 32 mm (122 .6' 4 cm) (4 (3.18 mm) 4 UP o ® o 0 all y 040 040 5.78° O , 5.87° "'°'' 5.67° 40000a�oou° .88 em) . (14.4 cm) 144 mm 14 �a�o�o�0444 A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL 1-Series Ordering Information Model Description Model Description Wall Horn Strobes _ Horns* P2RL . 2-Wire,Horn*Strobe,Red HRL* Horn,Red P2WL 2-Wire,;Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,.Comp.2.fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain . TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,iHorn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,;Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red P4RL 4-Wire,:Horh Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe;White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe„White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P'. Strobe,.Red,-Plain SWL-P Strobe,White,Plain SRLSP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing'(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 @2018 System Sensor. Phone:800-SENSOR2 a Fax:630-377-6495' Product specifications Subject to change vthout notice.Visit systemsensoccom �4 SENSOR® y for current product information,including he latest version of this data sheet www.s stemsensorcom AVDS885-05.2122/2018 i df-60379:A1 •E-400 CRF-300(A) @,Fire-LMALarms Relay Module -by. Honeywell Addressable Devices General The CRF-300(A)Addressable-Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming,on a select basis. LiteSpeedT"' is a !communication protocol developed by ` Fire•Lite Engineering that greatly enhances the speed of com- • »a. munication between analog intelligent devices. Intelligent o" devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of TI _. aNblt UNUSED other designs. T9� T. Features • Built-in type identification automatically identifies these devices to the control panel. o • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral.LED "blinks" green each time a communication is CRF-300(A) received from the control panel and turns on in steady red when activated. . • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. Specifications • Direct-dial entry of address:01-159 for MS-9600(A)series Normal operating voltage: 15 to 32 VDC. panels,01 —99 on MS-92000DLS(A)and MS-9050UD(A). Maximum SLC current draw: 6.5 mA(LED on). Average operating current: 230 pA direct poll (CLIP mode), Applications; 255 pA group poll(LiteSpeed mode)with LED flashing. The CRF-300(A) may be programmed to operate dry contacts EOL resistance: not used. for door holders,Air Handling Unit shutdown,etc.,and to reset four-wire smoke detector power. Temperature range: 320F to 120OF(0°C to 490C). Humidity range: 10%to 93%non-condensing. Construction Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x • The face plate is made of off-white heat-resistant plastic. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x • Controls include two rotary switches for direct-dial entry of 2.125" (5.398 mm)deep box. address setting. • The CRF-300(A)is configured for a single Class B(Style Y) Relay Contact Ratings or Class A(Style Z)Notification Appliance Circuit. Maximum Current • The CRF-300(A)i provides two Form-C dry contacts that Load Description Application Voltage Rating switch together. Resistive Non-Coded 30 VDC 3.0 A Operation Resistive Coded 30 VDC 2.0 A Each CRF-300(A)uses one of the addresses on a SLC loop. It Resistive Non-Coded 110 VDC 0.9 A responds to regular polls from,the control panel and reports its Resistive - Non-Coded 125 VAC 0.9 A type and status, including the open/normal/short status of its Notification Appliance Circuit(NAC).The LED blinks with each Inductive(L/R=5ms) Coded 30 VDC 0.5 A poll received.On command,it activates its internal relay. Inductive(L/R=2ms) Coded 30 VDC 1.0 A NOTE.Open/short supervision is suspended with the CRF-300. Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable)will identify the module to the con- trol panel,so as-to differentiate between a control module and a relay module. df-60379:A1•08/04/09—Page 1 of 2 Agency.Listings: g y. gs:and.Approvals- . In some cases;certain modules may not be listed by certain approval'agencies, or listing may:be in process. Consult fac- tory for latest listing Status. •.UL:S2424 • ULC:.S2424 • FM approved •.CSFM:7300-0075:185 • MEA:72.01-E Product. Lime Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed-model. SMB500:Optional surface-mount backbox. NOTE: For.installation instructions, see document 156-1190-005 and refer to the.SLC Wiring Manual,document 51309. LiteSpeedTM is a trademark and.Fire•LiteO Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This,document is not-intended to be used for installation purposes. Iso"900 We try to keep.our product information up-to-date and accurate. We cannot cover all:specific applications oranticipate all requirements. ENGINEIENi A MRNUE M111INi All specifications are subject to change without notice. QUALITY SYSTEMS Madain the U.S.A. For more information,contact Fire-Lite Alarms,Phone:(800)627-3473,FAX:.(877):699=4105. www.firelite.com Page 2 of 2—df-60379:At•08/04/09- USER'S MANUAL First Alerf CARBON MONOXIDE ALARM 10 YEAR SEALED BATTERY OPERATED CARBON- CONFORMS TO MONOXIDE ALARM WITH DIGITAL UL STD 2034 DISPLAY AND SILENCE FEATURE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Model C0710 ` o000000 IMPORTANT!PLEASE READ CAREFULLY AND SAVE. The warnings/limitations card and manual contains impor(ant information about your Carbon Monoxide(CO)Alarm's o operation.If you are installing this CO Alarm for use by others,you must leave this manual—or a copy of it—with the G G O a c G end user.Reference product card for additional information. HOW YOUR CO ALARM WORKS - GENERAL INFORMATION AWARNING! • CO Alarm contains a sealed,non-replaceable battery.Once it reaches the end of its service life,or after 10 years—whichever comes first=you must install a new CO Alarm. • High temperatures,low temperatures,high humidity,impact or dropping can adversely affect LCO displays. A CO Alarm measures the CO levels in the air.It will alarm-if CO levels rise quickly(if the heat exchanger on your furnace breaks,for example),or if CO is consistently present(a slow CO leak on.a fuel-burning appliance). This carbon monoxide alarm features a permanently installed sensor,digital display with blue backlight,and an 85 dB alarm horn.It also has a silence feature to temporarily quiet the alarm horn.During standby,the temperature is displayed in degrees F. THE PARTS.OF YOUR CO ALARM �1,3,5 2 1.Test Button 0 0 0 0 0 0 0 0 0 0 2.Activation+Deactivation tab(back of unit). 0 0 0 0 0 0 0 3.Silence Button 0000000 4.(Behind Cover)Alarm Horn:85dB audible alarm for test,alarm,and 6 unit malfunction warning. 5.Peak level.Button. 0 0 0 0 0 0 0 6.Digital Display with blue backlight. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ' 4 UNDERSTANDING YOUR CO ALARM IMA"RACUATE MMW rrr Display glows and horn chirps when Alarm is first activated. ,---I-0.0 .: ��L, . DIGITAL DISPLAY:All segments are turned on for a short time upon initial power. �ro�Xv CE Then the temperature is displayed in degrees F. ALARM RECEIVING BATTERY POWER •F Horn is silent.Temperature will be displayed in degrees F. DURING TESTING One beep sounds when you press button.It is later followed by a 4 beep pattern that comes twice. , o FFm "=°AIS F� DIGITAL DISPLAY: ' ' 7'� � Display glows and shows 1st". �� & ��� M ve m FRESH As Several ppm CO levels are also displayed and the alarm level is shown increasing. Continued... ®2015 BRK Brands,Inc.All rights reserved.Distributed by BRK Brands,Inc. • First Alert'Is registered trademark of The First Alert Trust•3901 Uberty Street Road,Aurora,IL 60504-8122 Consumer Affairs:(800)323-9005•www.firstalertcom www.brkelectronics.com • Printed In Mexico•MOB-0534-001•4/15 UNDERSTANDING YOUR CO ALARM Continued.. EVACUATE PPM CO ALARM:Sensor has detected enough CO to trigger an alarm.Blue backlight glows and horn sounds � loudly(repeating 4 beeps,pause).See"If Your CO AlarmSounds"for details.During an alarm,move everyone to a source of fresh air.DO NOT move the CO Alarm! DIGITAL DISPLAY:"CO"alternating with the ppm number,a full level,and"EVACUATED. MOVE TO FRESH AIR CO ALARM REQUIRES SERVICE(MALFUNCTION-SIGNAL) 'mow The horn-sourlds 3"chirps"every minute.CO Alarm needs to be replaced. DIGITAL DISPLAY:"Err"is displayed. CO ALARM END OF LIFE ' W— —' The horn sounds 5 chirps everyjminute.CO Alarm needs to be replaced. DIGITAL DISPLAY:"End"is displayed. USING THE PEAK CO MEMORY The CO Memory Feature lets you check the highest level of CO recorded during an alarm. _ MEMORY PPM NOTE:These bars will not appear when CO accumulation is low.The bars will be displayed when unit is exposed for a longer time and CO accumulation is higher. To check CO Memory: 1. Press and release the Test;Button until the peak CO level is displayed. MEMORY PPM MEMORY PPM To clear CO Memory I i 1 1. Automatically resets-after 24 hours. 1.1 2a. -Press and release Test Button until blue backlight glows. CLEAR 2b. Press and release Test Button to enter"clear mode". 2c. Press and release Test Button quickly one more time to clear. NOTE:Must press and release.Press and hold will run into"Test Mode". NOTE:The highest CO level'will.be saved for 24 hours.DO NOT clear the CO Memory reading if you plan to call someone to investigate a CO problem!Clear the CO Memory reading only after the investigator has checked your home.If the investigator will not arrive within the 24 hour time period before the unit automatically resets,be sure to write down the peak level. INSTALLATION -WHERE TO INSTALL CO ALARMS The National Fire Protection Association(NFPA)recommends that a CO Alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms.For added protection,install additional CO Alarms in each separate bedroom,and on every level of your home. If your bedroom hallway is longer than 40 feet(12 meters),install a CO Alarm at BOTH ends of the hallway. In a Single-level Home: • Install at least one CO Alarm near or within each separate sleeping area. • For added protection,install an additional CO Alarm at least 20 feet(6 meters)away from the furnace or fuel burning heatsource. In a Mufti-level Hama: BEDROOM 'BEDROOM BEDROOM • Install at least one CO Alarm near or.within each separate sleeping area. KITCHEN cARADE • For added protection,install at least one CO Alarm on each level of the home.If you have a LIVING ROOM NALL basement,install that CO Alarm at the top of the basement stairs. O For added protection,install an additional CO Alarm at least 20 feet(6 meters)away from the furnace or fuel burning heat source. fom/ BASEMENT O In a Mobile Home: O REQUIRED TO MEET NFPA RECOMMENDATIONS . Install CO Alarms on inside walls ONLY.Uninsulated outside walls and roofs of mobile homes often ♦SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS transfer heat and cold from outdoors. WHERE CO ALARMS SHOULD NOT BE INSTALLED DO NOT install this CO Alarm: • In garages,kitchens,furnace rooms,or in any extremely dusty,dirty or greasy areas. • Closer than 20 feet(6 meters)from a furnace or other fuel burning heat source,or fuel burning appliances like a water heater. • Within 5 feet(1'5.meters)bf any cooking appliance. • In extremely humid areas.This alarm should be at least 10 feet(3 meters)from a bath or shower,sauna,humidifier,vaporizer,dishwasher,laundry room,utility room-or other source of high humidity. • In areas where temperature is colder than 40°F(4.4°C)or hotter than 100*F(37.8'Q.These areas include unconditioned crawl spaces,unfinished attics, uninsulated or poorly insulated ceilings,porches,and garages. • In turbulent air,like near ceiling fans,heat vents,air conditioners,fresh air returns,or open windows.Blowing air may prevent CO from reaching the sensors. • In direct sunlight. HOW TO INSTALL YOUR CO ALARM Read"Where To Install CO Alarms"before starting. Before you start installation,find the pair df-self-adhesive labels included with this CO Alarm.On each label write in the phone number of your emergency responder(like 911)and-a qualified appliance technician.Place one label near the CO Alarm,and the other label in the"fresh air"location you plan to go if the alarm sounds. NOTE:Activate alarm prior to mounting. 1 1. Activating the Battery.Move the activation switch to ON position.Utilize a small tool to help O "� m O activate:switch if needed.Once.unit is activated,it cannot be turned:off. tiOw NOTE::Horn chirps,and all segments are turned on for a short.time upon activation: ®� awaaNw�� 2. Test the CO Alarm.See"Weekly Testing". m ♦re 3. To Permanently Deactivate The Alarm.This CO Alarm contains a sealed,non-replaceable battery. Once it reaches the-end of its service life;or after 10 years you-must install a new CO Alarm:Deactivate O the CO Alarm by inserting a tool below edge where shown and break tab.Then slide activation switch to -3 DEACTIVATE mode. NOTE:Once you deactivate this unit,it will not detect CO or alarm and cannot be reactivated. 4. This CO Alarm can.either bewall mounted or placed on a tabletop.If Alarm is placed on a tabletop,be sure the Alarm is no more than 3 feet(0.9 meter)from the floor to minimize the risk of causing-permanent damage to the Alarm in the event that it is accidentally knocked to the ground. TO MOUNT ON THEWALL Tools you will need:pencil,drill with 3/16"or 5mm drill bit,flathead.screwdriver,hammer,mounting template. 1. Choose a location on the wall.Do not,install the'Alarm closer than 4" (102 mm)from where the wall meets the ceiling. 2. Hold the mounting guide template against the wall,and make a mark inside each keyhole where you will drill your mounting holes as shown in the diagram below. 3. Use a 3/16"(5 mm)drill.bit to drill through.the marks you made for the mounting holes. 4. Insert the plastic screw-anchors into the:mounting holes until they are flush with the wall.If necessary,tap them gently with a hammer.. 5. Insert the screws into the anchors until-the screwhead is 1/8 inch(3 mm)away from the wall. 6. Slide the CO Alarm onto the screws until you feel it click into place. 7. -'Test the CO Alarm as described in."Weekly Testing." Mounting Guide Template 2%inches(66.68 mm) IF YOUR CO ALARM'SOUNDS AWARNING: Actuation of your CO Alarm indicates the presence of carbon monoxide(CO)which can kill you.In other words,when your CO Alarm sounds,you must not ignore it! See"General Limitations of CO Alarms"for details included in the card.packaged with alarm. IF THE ALARM SIGNAL SOUNDS: 1. Operate the Silence button. 2. Call your emergency services,fire department.or 911.Write down the number of your local emergency service here: 3. Immediately move-to fresh air--outdoors or by an open door or window.Do a head count to check that all persons are accounted for.Do not re-enter the premises,or move away from the open door or window until the emergency services responder has arrived,the premises have been aired out,and your CO Alarm remains in its normal'condition. 4. After following steps 1-3,if your CO Alarm reactivates within a 24-hour period,repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances,and inspect for proper operation of this equipment.If problems are identified during this inspection have the equipment serviced immediately.Note any combustion equipment not inspected by the technician,and consult the manufacturers'instructions, or contact the manufacturers directly,for more information about CO safety and this equipment.Make sure that motor vehicles are not,and have not,been operating in an-attached garage or adjacent.to the residence.Write down the number of a qualified appliance technician here: Kidde Sealed Battery Carbon Monoxide Alarm Model COO LED Lights Green for normal operation, Red for alarm, Amber for Error. Tests CO alarm circuit operation and allows youto imm6diately silence the alarm. 10-Year Batteries continueUnit will • operate for 10 years. Alerts user to replace unit after 10 years of operation. Cartian P�l�ncrxicfe Aiarm' - F NE Tfl •Never Change a Battery! •CO Alarm lasts 10 Years. Description Features and Benefits The Kidde C3010 is a 10-year,sealed battery, carbon • Sealed-in Lithium Battery—Sealed-in lithium power monoxide alarm that uses electro-chemical sensing tech- supply; no battery replacement required over the 10 year nology to protect you and your family from the dangers life of the alarm. Eliminates worry about battery removal of carbon monoxide.'The C3010 alarm will automatically or unauthorized deactivation of alarm. activate when if is attached to the mounting bracket.At • Self Activation—Alarm automatically activates when' the end of alarm life,the unit will chirp, indicating the attached to the mounting bracket. alarm is in need of replacement. A screwdriver can be used to deactivate the unit, stopping the end-of-life chirp •Test/Reset Button—Tests the unit for proper operation. and making it safe for disposal. The inside cover of the Resets the Carbon Monoxide Alarm mounting bracket features a-quickreference guide for •Green LED—Flashes every 30 seconds to indicate the unit what to do in case of an alarm. This easy-to-install alarm is operating properly. is suitable for all living areas and has a 10 year life and • Red LED—When a dangerous level of carbon monoxide limited warranty. is detected the red LED will pulse and a loud alarm pattern will sound.The carbon monoxide alarm pattern is 4 short Consumer Benefits beeps,followed by 5 seconds of silence,followed by 4 short beeps with a corresponding red LED flash.This cycle The Kidde C3010 provides you and your family with a will continue for 4 minutes and then change to 2 patterns loud warning signal to dangerously elevated levels of car- once a minute there after. bon monoxide in your home.The unit contains a 10-year .Amber LED—Flashes every second to indicate the unit is tamper proof battery that eliminates the need for battery in fault mode. One quick beep every 30 seconds alerts the replacement, and provides continuous monitoring of CO unit is in error condition. One quick beep every 60 seconds levels, even during power outages.The Event Memory is an indication of low battery power. . feature alerts you if a high level of carbon monoxide has been detected within the last 14 days.The 10-year limited • Event Memory—Red LED flashes every 60 seconds to-alert warranty lasts the life of the alarm. that a high level of carbon monoxide has been detected W'% SIGNALING within the last 14 days. ULD geRa�' LISTED Sealled Battery .i.O C3010 Carbon Monoxide Allarm Architectural and Engineering Technical Specifications Specifications Power Source: Sealed Lithium Battery The carbon monoxide alarm shall be Kidde Model C3010 or approved Sensor: Electrochemical equal. It shall be powered'by a sealed lithium battery.The tempera- Audio Alarm: 85dB at 1 Oft ture operating range shall be:between 40OF and 100°F(4°C and 38°C) and the humidity operating range shall be 10% -95% non condens— ing relative humidity. Humidity Range: 10%-95% relative humidity(RH) The-CO sensor shall be of a fuel cell design and shall meet the sen- Size: 4.5"L x 2.75"H x 1.5" D sitivity requirements of Underwriters Laboratories UL2034 Single and Weight: .31 lb Multiple Station Carbon Monoxide Alarms. Wiring: No The alarm can be installed on the surface of any wall or placed on a Interconnects: No tabletop following the UUNFPA/Manufacturer's recommended place- ment guidelines. Warranty: 10 year limited The alarm shall include a test button that will electronically simu- late the presence of CO and cause the unit to go into alarm.This sequence tests the unit's electronics to ensure proper operation. 4.5" t— 1.5" -► Per UL 2034 requirements,the CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding levels of CO. r� 10 70 ppm CO Concentration 60—240 minutes 150 ppm CO Concentration 10—50 minutes 400 ppm CO Concentration I, 4—15 minutes The unit shall incorporate 3 LEDs.A green LED will flash once every 30 seconds to indicate the alarm is operating properly when power is present.A red LED will pulse to indicate carbon monoxide has been detected until the device is reset or CO is eliminated.An amber LED will flash every second to signal alarm malfunction or low battery. The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet.When the unit detects carbon monoxide,the alarm pattern will be four(4)short beeps—'followed by five(5)seconds of silence— followed by four(4)short beeps with a corresponding red LED flash. It shall include a 10-year manufacturer's limited warranty. Ordering Information Part Number UPC Pack Quantity Dimensions(w x d x h) 12 of 5 Weight Items/Skid 21010045 0-47871-10045-3 3-PK(clam) 8 x 9.5 x 11.5 100-47871-10045-0 1.35 lb. 225 21010073 0-47871-10073-6 6-PK(box) 6.25 x 10.75 x 4.25 100-47871-10073-3 6.00 lbs. 1296 Kidde' Distributed.by: 1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 www.Kidde.com KL-0010 sheet rev.03-2014 USING THE.SILENCE FEATURE &WARNING! • The Silence Feature is for your convenience only and will not correct While the detector is silenced: a CO problem.Always check your home for a potential problem after any alarm.Failure to do so can result in injury or death. If the CO Alarm... This means... The Silence Feature is'intended to temporarily silence your CO Alarm's alarm horn while you correct the problem—it will not correct a CO problem.While the Is silent for only 4 minutes,then alarm-is silenced it will continue to monitor the air for CO. starts sounding loudly-4 beeps, CO levels are still To Activate the.Silence Feature:Press:and hold the Silence button until the pause,4 beeps,pause potentially dangerous. horn is silent. Once you'activate the Silence Feature:the Silence cycle will last If the CO Alarm... This means... approximately 4 minutes. Remains silent after you pressed. . NOTE,After initial 4-minute Silence cycle,the CO Alarm re-evaluates present the Silence button CO levels are dropping. CO levels and responds accordingly.If CO levels remain potentially dangerous -or start rising higher-the horn will start sounding again. SILENCING THE END OF LIFE SIGNAL This silence.feature can.temporarily.quiet the End of Life warning"chirp"for 8 hours up to 7 days.You can silence the End of Life warning"chirp"by pressing the Silence button.The horn will chirp,acknowledging that the End of Life feature has been activated. TESTING & MAINTENANCE '- WEEKLY TESTING ,&WARNING! ' • Test the CO Alarm once a week.If the CO Alarm ever falls to test correctly,have it replaced immediately!If the CO Alarm is not working properly,it cannot alert you to a problem. • DO NOT stand close to the Alarm when the horn is sounding.Exposure at close range may be harmful to your hearing.When testing,step away when horn starts sounding. You can test this CO Alarm by pressing the Test button on the Alarm cover until alarm chirps.The alarm horn will sound:4 beeps,a pause,then 4 beeps.The alarm sequence should last 5-6 seconds.if the,unit does not alarm,make sure it has been activated correctly,and test again..If the unit still does not alarm,replace it immediately. ,&WARNING! • DO NOT try fixing the Alarm yourself—this will void your warranty!If the CO Alarm is still not operating properly,and it is still under warranty, please see"How to Obtain Warranty Service"in the Limited Warranty.Install a new CO Alarm.immediately. • NEVER use vehicle exhaust to test your Alarm!Exhaust may cause permanent damage and voids your warranty REGULAR MAINTENANCE To keep the CO Alarm in good working order: • Test it every week using the Test button. • Vacuum the CO Alarm cover once a month,using the soft brush attachment.Never use water,cleaners,or solvents,since these may damage the unit.Test the CO Alarm again after vacuuming. ,&WARNING!- • Please dispose of or recycle the Alarm properly,following any local regulations.Consult your local waste management authority or recycling organization to find an electronics recycling facility in your area.DO NOT DISPOSE OF ALARM IN FIRE.BATTERIES MAY EXPLODE OR-LEAK. • DO NOT spray cleaning chemicals or insect sprays directly on or near the CO Alarm.DO NOT paint over the CO Alarm.Doing so may cause permanent damage. IMPORTANT!. Household cleaners,aerosol chemicals,and other contaminants can affect the sensor:When using any of these materials near the CO Alarm;make sure'the room is well ventilated. WHAT YOU NEED,.TO KNOW ABOUT CO - WHAT IS CO? CO is an invisible,odorless,tasteless gas produced when fossil fuels.do not burn completely,or are exposed to heat(usually fire).Electrical appliances typically do not produce CO. These fuels include:Wood,coal,charcoal,oil,natural gas,gasoline,kerosene,and propane. Because CO may dissipate by the time an investigator arrives,it may be difficult to locate the source of CO.BRK Brands;Inc.shall not be obligated to pay for any carbon monoxide investigation or service call. Fuel-burning appliances like:portable heater,gas or wood burning fireplace,gas kitchen range or-cooktop,gas clothes dryer. Damaged or insufficient venting:corroded or disconnected water heater vent pipe,leaking chimney pipe or flue,or cracked heat exchanger,blocked or clogged chimney opening. Improper use of appliance/device:operating a barbecue grill or vehicle in an enclosed area(like a garage or screened porch). Transient CO Problems:"transient"or on-again-off-again CO problems can be caused by outdoor conditions and other special circumstances. A CO Alarm is not a substitute.for proper maintenance of home appliances. TROUBLESHOOTING GUIDE PROBLEM... THIS MEANS... YOU SHOULD... MALFUNCTION SIGNAL.Based on its Self Test CO Alarms under warranty should be returned to The horn sounds 3"chirps"every minute. diagnostics,the unit has detected a malfunction. manufacturer for replacement.See"Limited The unit needs to be replaced. Warranty"for details. The horn sounds 5"chirps"every minute. END OF LIFE SIGNAL. Immediately replace the CO Alarm. CO Alarm needs to be replaced. IF YOU ARE FEELING SYMPTOMS OF CO CO Alarm goes back.into alarm•4 minutes after you CO levels indicate a potentially dangerous situation. POISONING,EVACUATE your home and call 911 or press the Test/Silence button. the Fire Department.If not,press the Test/Silence button again and keep ventilating your home. Relocate your alarm.If frequent alarms continue, CO Alarm sounds frequently even though no high The CO Alarm may be improperly located.Refer to have home rechecked for potential CO problems. levels of CO are revealed in an investigation. "Where to Install CO Alarms." You may be experiencing an intermittent CO problem. If you have any questions that cannot be answered by reading this manual,call Consumer Affairs at 1-800-323-9005. LIMITED WARRANTY BRK Brands,Inc.("BRK")the maker of BRK®brand and First Alert®brand products,warrants that for a period of ten years from the date of purchase,this product will be free from defects in material and workmanship. BRK,at its option,will repair or-replace this product or any component of the product found to be defective during the warranty period.Replacement will be made with a new or remanufactured product or component.If the product is no longer available,replacement may be made with a similar product of equal or greater value.This is your exclusive warranty. This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable.Keep the original sales receipt:Proof of purchase is required to obtain warranty performance.BRK dealers,service centers,.or retail stores selling BRK products do not have the right to alter,modify or any way change the terms and conditions of this warranty. This warranty does not cover normal wear of parts or damage resulting from any of the following:negligent use or misuse of the product,use on improper voltage or current,use contrary to the operating instructions, disassembly,repair or alteration by anyone other than BRK or an authorized service center.Further,the warranty does not cover acts of God,such as fire,flood,hurricanes and tornadoes or any batteries that are included With this unit, BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty.Except to the extent prohibited by applicable law,any implied warranty of merchantability or fitness for a particular purpose is limited induration to the duration of the above warranty.Some states,provinces,or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warrantylasts,so the above limitations or exclusion may not apply to you.This warranty gives you specific legal rights,and you may also have other rights that vary from state to state, or province to,province. How to Obtain Warranty Service Service:If service is required,do not return the product to your retailer.In order to obtain warranty service,contact the Consumer Affairs Division at 1-800-323-9005,7:30 AM to 5:00 PM,Central Standard Time,Monday through Friday.To assist in serving you,please have the model number and date of purchase available when calling. 1301 Joe Battle,El Paso,TX 79936 Disposal:Waste electrical products should not be disposed of with regular household waste.Please recycle where facilities exist.Check local requirements for disposal of Li-Ion electronic devices. The Alarm should be deactivated before disposal.See"To Permanently Deactivate The Alarm".You can also return your Alarm to us for disposal.For return address see above.Please include a note confirming the product is being returned for disposal. The alarm will also provide an audible End-of-Life Signal approximately 10 years after installation to remind you to replace the unit The End-of-Life Signal can be silenced for up to 7 days.Do not deactivate alarm until you have a replacement. For your records,please record: Date Purchased: Where Purchased: Date Installed: / Month/Year Replace alarm 10 years after installation.Please write the date in the space provided: / Month/Year DF-60957:D ES-20OX Series Intelligent AddressableIcACP ' FIM-LITe°ALarMS Fire Alarm Control'Panels by Y Hone well. Addressable Fire Alarm Control Panels General The ES-200X, ES-200XC, ES-200XI, and ES-200XP are the latest intelligent addressable Fire Alarm Control Panel(FACP)from Fire•Lite Alarms and is-a direct replacement for the.MS-92000DLS. The ES- 200X support up to-198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the ES-20OX Series programs just like Fire•Lite's other addressable products, yet fits into applications-previously served only by conventional panels. The ES-20OX and ES-200X0 feature a pre-installed IPOTS-COM, a dual technology (POTS and IP) communicator. The POTS transmits system status(alarms,troubles,AC loss,etc.)to a Central Station via the public switched telephone network. The IP communicator's inter- net monitoring capability'sends.alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines.Although. not required, the secondary telephone line may be retained providing backup communication- over; the public switched telephone line. Optional cellular reporting is; available using an HW-TG7F Series Communicators or the CLSS Pathway. The ES-200XP features an integrated'CLSS Pathway Pro Communi= cator,-a dual-SIM (AT&T/ Verizon).5G LTE-M Communicator with optional IP connection.The CLSS Pathway-Pro transmits system sta- tus (alarms, troubles, AC loss, etc.) to the Central Station using LTE CAT-M1 networks,serving asp bridge between the fire system and the CLSS Cloud. The IP communicator's Internet monitoring-capability . Selectable strobe synchronization for System Sensor, Wheelock, sends alarm signals over the Internet, meeting requirements for and Gentex devices backup communication. As an integrated communicator, the CLSS Notification Appliance Circuit End of Line resistor matching Pathway Pro,typically,can transmit data faster than dial capture meth-ods. • Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Remote and local programming of the control panel is'possible using • Built-in Programmer the FS-Tools Upload/Download utility.Programming databases can be • Integral 80-character LCD display with backlighting uploaded/downloaded via the panel's USB port(and USB cable)or via • Real-time clock/calendar with automatic daylight savings control an ethernet connection using the IPOTS-COM communicator • History file with 1,000 event capacity (ES-200X and EX-20OXC only). The USB port also allows for the • Addressable sounder base compatibility download or,upload of the entire program, history file,walk-test data, • Multi-criteria detector (smoke, heat, CO) with programmable current-status and system voltages by.means of a USB flash drive. response The power supply and all electronics are contained on a circuit board • Control module delay timer supported on a new quick install chassis and housed in a metal cab!- ' Automatic detector sensitivity testing(NFPA 72 compliant) net.Available accessories include local and remote upload/download • Automatic device type-code verification software, remote annunciators, and reverse polarity/city box transmit- ' Point trouble identification ter(4XTMF). • Waterflow selection per module point • Alarm verification selection per-detector point Features • Maintenance alert warns when smoke detector dust accumulation is excessive • Listed to UL Standard 864, 10th edition • One-person audible or silent walktest with walktest log and printout • Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- • System alarm verification selection per detector point phone Service). Central Station Communicator (ES-200X and • PAS(Positive Alarm Sequence)and Pre-signal per point(NFPA 72 EX-20OXC only) compliant) • Optional Cellular Central Station Communicators over AlarmNetO • Up to 16 ANN=BUS annunciators-8 per each ANN-Bus (ES-200X and EX-20OXC only) • Remote Acknowledge,Alarm Silence, Reset and Drill via address- 0 Integrated CLSS Pathway Pro Communicator;dual SIM AT&TNeri- able modules or remote annunciator zon networks with LTE-CAT-M1 5G technology(EX--200XP only) • Upload/Download of program and data via USB with optional • Cloud .monitoring using Honeywell's Connected Life Safety Ser- FS-Tools Programming Utility vices(CLSS)Cloud solutions software(EX-200XP only) SLC(DCL) COMMUNICATION LOOP • -Automated activation of the ECC-50/100.Emergency Command . Supports LiteSpeedTm and CLIP protocols Center T Firefighter Telephone option • SLC(DCL) operates up to 10,000 ft. (3,000 m) in LiteSpeed mode ECC-• with twisted,unshielded wire Compatible with SWIFTO wireless devices • Auto-programming(learn mode) reduces installation time. Reports Single addressable SLC (DCL) loop which meets NFPA Class B two devices set to the same address and Class A requirements • Four built-in, independently programmable, Class A or Class B • 198 addressable device capacity(99 addressable detectors and 99 NAC circuits modules) DF-60957:D•3/27/2023—Page 1 of 4 a Compatible with•Fire•Lite's addressable devices (refer to the SLC HW-TG7FE-A/HW-TG7FE-V: CLSS-Enabled- 5G/LTE-M Dual Path Wiring Manual) Commercial Fire Alarm Communicators for AT&T and Verizon NOTIFICATION APPLIANCE CIRCUITS(NAGS) .. �. �.W-TG7FP-A/HW-TG7FP-A: CLSS-Enabled 5G/LTE-M Sole Path •Commercial Fire Alarm Communicators for AT&T,and Verizon • Four independently programmable output circuits. Circuits-can be #,DP-ES-R:Optional dress panel for the. configured for Class A Pr Class 5wiring . Silence Inhibit and Autosilence timer.options TR-CE:Optional trim ring for semi=flush mounting. • BB-2F:Optional cabinet for one or two modules. Continuous,March Time,Temporal,or California code for main cir- cuit BB-6F Optional cabinet for up to six modules mounted on CHS-6 board NACs with two-stage capability chassis. • Selectable strobe synchronisation per NAC BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- • 2.5 A special application,250mA regulated;total power for NACs: 75: NOTE:Maximum or total 24VDC'system'power shared between all NAC BB-55F: Battery box,houses two 55 AH batteries circuits and the ANN-BUS is 2:7;A CHS-6:Chassis, mounts up to six multi-modules in a BB-6F cabinet. PROGRAMMING AND SOFTWARE CHG-75: Battery charger for lead-acid batteries with a rating of 25 to • Autoprogramming(learn mode) reduces installation time 75 AH. • Custom,English labels (per point) -may be manually entered or CHG-120F: Remote battery charging system for lead-acid batteries selected from an internal library file with a rating of 55 to 120 AH. Requires additional BB-55F for mount- Two programmable Form-C relay outputs ing. • 99 software zones NOTE.CHG-120F or CHG-75 required for batteries larger than 18AH. • Continuous fire protection during online programming BAT Series:Batteries,see data sheet DF-52387. • Program Check automatically catches common errors not linked to PRN Series; UL listed compatible event printer. Uses tractor-fed any zone or input.point paper. • OFFLINE PROGRAMMING: Create the entire program in your OPTIONAL MODULES office using FS-Tools;-a Windows®-based software package, and upload/download systemprogramming locally.Offline programming 4XTMF Reverse Polarity Transmitter Module: Provides a super- requires an ethernet connection. FS-Tools is available on vised output for local energy municipal box transmitter,alarm and trou- www.firelite.com. ble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. User interface Increases alarm power output to 6 amps. LED INDICATORS COMPAT/BLEANNUNC/ATORS • Fire Alarm(red), CO Alarm(yellow) ANN-80: Remote LCD annunciator mimics the information displayed • AC Power(green) Supervisory(yellow) on the FACP LCD display. Recommended wire type is un-shielded. • Trouble(yellow) Ground fault(yellow) ANN-100: Remote LCD annunciator mimics.the information displayed. • Battery fault(yellow) Disabled(yellow) on the FACP LCD display. Recommended wire type is un-shielded. • For use in FM applications only. Maintenance(yellow) Communication(yellow) • Alarm Silenced(yellow) F1-F4 Programmable Function ANN-UO: LED Driver Module provides connections to a user supplied Keys(yellow) graphic annunciator.(See.DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone; KEYPAD Alarm, Trouble, and Supervisory:Ships with red-enclosure. (See DF- 16 key alpha-numeric-pad Acknowledge 60241.) • Alarm.Silence Drill(Manual Evacuate) ANN-BLED: Provides alarm (red) indicators for up to 30 input zones • Four(4)programmable function keys Reset(lamp test) or addressable points.(See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. PRODUCT LINE INFORMATION Can be mounted inside the cabinet.(See DF-52431.) ES-20OX: Addressable Fire Alarm Control'Panel with one SLC loop. ANN-S/PG Serial/Parallel Printer Gateway module provides a con- Includes main circuit board with display, pre-installed communicator, nection for a serial or parallel printer.(See DF-52429.) chassis with transformer, backbox with door, plastic bag containing ADDRESSABLE DEVICES screws,cables,key,etc. ES-200XC:Addressable Fire-Alarm Control Panel with one DCL loop. All feature a polling LED and rotary switches for addressing. Includes main circuit board.with display, pre-installed IPOTS-COM SD365(A):Addressable low-profile photoelectric smoke detector.Lite- communicator, chassis with transformer, dress panel, backbox with Speed only. door-,plastic bag containing screws,cables,key,etc. SD365(A)-IV: Addressable low-profile photoelectric smoke detector. ES-200XI- Addressable Fire-Alarm Control Panel with one SLC loop. Ivory.LiteSpeed and CLIP mode. Includes main circuit, board with display, chassis with transformer, SD365T(A): Addressable low-profile photoelectric smoke detector dress panel,backbox with door,plastic bag containing screws,cables, with thermal sensor.LiteSpeed only. key,etc. SD365T(A)-IV:Addressable low-profile photoelectric smoke detector ES-200XP:Addressable:Fire Alarm Control Panel with one SLC loop. with thermal sensor. Ivory.LiteSpeed and CLIP mode. Includes main circuit board•with display, pre-installed CLSS Pathway Pro communicator, chassis with transformer, dress panel; backbox SD365R(A): Remote test capable addressable photoelectric smoke with door,plastic bag containing screws,cables,key,etc. detector for use with DNR(W)duct detector housing.LiteSpeed only. FS-Tools: Programming software for Windows@)-based PC computer. SD365R(A)-IV:Remote test capable addressable photoelectric smoke Available for download at www.firelite.com. detector for use with DNR(W)duct detector housing.ivory.LiteSpeed IPOTS-COM: Dual. technology (POTS and IP) communicator. and CLIP mode. (replacement board)(ES-200X and EX-20OXC only) SD365CO: Addressable, low-profile device that provides fire, heat, HW-AV-LTE-M:Optional CLSS Pathway and carbon monoxide(CO)detection,LiteSpeed only. HW-TG7FS-A/HW-TG7FS-V: CLSS-Enabled 5G/LTE-M Commercial SD365CO-IV:Addressable, low-profile device that provides fire,heat, Fire Alarm Communicators for AT&T@ and Verizon@) and carbon monoxide (CO) detection. Ivory.-LiteSpeed and CLIP mode: Page 2 of 4—DF-60957:D•3/27/2023 H365(A):Low-profile 135°F fixed thermal sensor.LiteSpeed only. BG-12LX: Addressable manual pull•station with interface module H365(A)-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed mounted inside. and CLIP mode. 1300(A): This module isolates the SLC'loop from'short circuit condi- H365R(A): Low-profile, intelligent, rate-of-rise thermal sensor. Lite- tions(required for Class A or Class X operation). Speed only. ISO-6(A): Six-fault isolator module. Mount one or-two modules in a H365R(A)-IV: Low-profile, intelligent, rate-of-rise thermal sensor. BB-2F cabinet(optional).:Mount up to six modules on a CHS-6 chas- Ivory.LiteSpeed and.CLIP mode. sis in a BB-6F cabinet. H365HT(A): Low-profile intelligent 190°F/88°C fixed thermal sensor. SMB500: Used to mount all modules except the'MMF-301(A) and LiteSpeed only. M301(A), H365HT(A)-IV: Low-profile intelligent 190117/881C fixed thermal sen- MMF-300-10(A): Ten-input monitor module. Mount one or two mod- sor. Ivory.LiteSpeed and CLIP mode. ules in a BB-2F cabinet'(optional).Mount up to six modules on a CHS- 6 chassis in a BB-6F cabinet. D365PL:Low-flow non-relay duct-detector housing;includes SD365R. MMF-302-6(A):Six-zone interface module.Mount one or two modules Legacy Devices in a BB-2F cabinet.(optional). Mount up to six modules on a CHS-6 CP355(A):Addressable low-profile ionization-smoke detector. chassis in a BB-6F cabinet. SD355(A):Addressable low-profile photoelectric smoke detector. CMF-300-6(A): Six-circuit supervised control module. Mount one or SD355T(A): Addressable low-profile photoelectric smoke detector two modules in a BB-2F cabinet (optional). Mount up to six modules with thermal sensor.. on a CHS-6 chassis in a BB-6F cabinet. SD355R(A): Remote test capable addressable photoelectric smoke . CRF-300-6(A): Six-relay control module (Form-C relays). Mount one detector for use with DNR(W)•duct detector housing. or two.modules.in a BB-2F cabinet(optional).Mount up to six modules on a CH.S-6 chassis in a BB-6F cabinet. SD355CO:-Add ressable, low-profile device that provides fire, heat, SWIFT Wireless Devices and carbon monoxide(CO)detection. H355(A): Fast-response, low-profile heat detector. .. W-GATE(A):LiteSpeed Wireless Gateway H355R(A): Fast-response, low W-SD355(A):LiteSpeed intelligent,•wireless photo detector.-profile-heat detector with rate-of-rise W-H355R(A): LiteSpeed intelligent wireless rate of rise (1350) heat option. detector. H355HT(A): Fast-response, low-profile heat detector that activates at W-Sctor., 190°F/88°C. A)•intelligent wireless photo/heat detector. AD355(A)• Low=profile, intelligent, "Adapt' multi-sensor detector W-H355(A): LiteSpeed intelligent wireless fixed-temperature (135°) (B350LP,base included). heat detector. B200S(A)(-WH)(-IV):.:Prograrnmable,addressable sounder base. W-MMF(A):LiteSpeed Intelligent wireless monitor module. W-CRF(A):LiteSpeed Intelligent wireless relay module. B200SR(A)(-11VH)(-IV):Addressable sounder base. W-BG12LX(A):LiteSpeed Intelligent wireless pull station. B200S-LF(-W. H)(-IV):Programmable;addressable sounder base,low- - WAV-RL, WAV-WL;WAV-CRL,WAV-CWL: LiteSpeed Intelligent-AV frequency. buses: .. -B200SR-LF(-WH)(-IV):Addressable sounder base,low-frequency. W-USB: Wireless USB radio/antenna dongle that plugs into the USB BEAM355: Intelligent beam smoke detector. port of a PC.running SWIFT Tools. BEAM355S: Intelligent beami smoke detector'with integral sensitivity - SWIFT Tools: Programming and diagnostic utility for.the Wireless test. Gateway and devices.Available for download from firelite.com. D355PL(A): InnovairFlex low-flow non-relay duct-detector housing; NOTE:For more information on Compatible Addressable Devices for use includes SD355R. with the ES-200X, see the following data sheets (document numbers): DNR(A): InnovairFlex low-flow non-relay duct-detector housing. SD365 Series(DF-61010), H365 Series (DF-61011),AD355(DF-52386), BG-12LX (DF-52013); CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), (Order SD355R(A)/SD365R(A)separately.) CMF/CRF Series (DF-52130), -CP355 (DF-52383), H355 Series (DF- DNRW: InnovairFlex low-flow-non-relay duct-detector housing, with 52385), 1300 (DF-52389), ISO-6 (DF=60485), MMF-300 Series/MDF-300 NEMA-4 rating. Watertight.,(Order SD355R(A)/SD365R(A) sepa- (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD3551 eately.) SD355T(DF-52384),and SLC Wiring Manual(51309). Addressable Modules NOTE:Legacy 300 Series detection devices such as the CP300/CP350, MMF-300(A): Addressable Monitor Module for one zone of normally- SD300(7)/SD350(7) and older modules such as the M300;M301, M30Z open dry-contact initiating devices. Mounts in standard 4.0" (10.16 C304,and BG10LX are-not compatible with LiteSpeed polling.If the SLC cm.)box. Includes plastic cover plate and end-of-line resistor. Module contains one of these devices,polling must be set for standard CLIP proto- may be configured for either a Class B or Class A IDC. col. Please consult factory for further information on previous 300 Series devices. MDF-300(A): Dual Monitor Module. Same as MMF-300(A) except it provides two.Class:B-only,IDCs. ADDRESSABLE DEVICE ACCESSORIES MMF-301(A):-Miniature version of MMF-300(A)..Excludes.LED and End-of-Line.Resistor Assembly(R-47K and R-3.9K):The 47k ohm Class A option.Connects with'-wire pigtails.May mount in device back- assembly supervises the MMF-300(A);.MDF-300(A), MMF-301(A), box. and CMF-300(A) module circuits.The 3.9k ohm assembly supervises MMF-302(A):Similar to MMF-300(A).Addressable Monitor Module for the MMF-302(A) module circuit. These resistors are included with one zone of conventional two=wire.detectors. Requires resettable 24 each module: VDC power. Refer to the Device Compatibility Document for listed Power Supervision Relay: Supervises the power to 4-wire smoke compatible devices and quantity limitation. detectors and notification appliances. CMF-300(A):Addressable Control Module for one Class B or Class A zone of supervised polarized'Notification Appliances. Mounts directly Wiring.Requirements to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 While shielded wire is not'required, it is recommended that all'SLC VDC to power notification appliances. (DCL)wiring be twisted-pair to minimize the effects of electrical inter- CRF-300(A): Addressable relay module containing two isolated sets ference.Refer to the panel manual for wiring details. of Form-C contacts,which operate as a DPDT switch. Mounts directly to a 4.0"(10.16 cm.)box,surface mount using the SMB500. DF-60957:1)•3/27/2023—Page 3 of 4 SYSTEM- SPECIFICATIONS System Capacity NFPA Standards • Intelligent Signaling Line Circuits...................................................1 The ES-20OX complies with the following NFPA 72 Fire Alarm'Sys- - Addressable device capacity.....................................................198 •tems requirements: • Programmable software zones....................................................99 —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- • Annunciators.........:.......................................................................16 sory)• —AUXILIARY (Automatic, Manual and Waterflow) (requires Electrical Specifications 4XTMF). AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, —REMOTE STATION(Automatic,Manual and Waterflow)(Where a DACT is not accepted,the alarm,trouble and supervisory relays auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 may be connected to UL 864 listed transmitters. For reverse mm2)with 600 V insulation.Non-power-limited,supervised. polarity signaling of alarm and trouble,4XTMF is required.) Battery: Two 12 V 18 AH,lead-acid batteries.Battery Charger Capac- —PROPRIETARY(Automatic,Manual and Waterflow). ity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH batter- —CENTRAL STATION (Automatic, Manual and Waterflow, and ies.) Sprinkler Supervised). Communication Loop: Supervised and power-limited. —OT,PSDN.(Other Technologies,.Packet-switched Data Network) Notification Appliance Circuits: Terminal Block provides connec- —IBC 2012,IBC 2009,IBC 2006,IBC 2003,IBC 2000(Seismic). tions for four NACs, Class B or Class A. Special Application power. —CBC 2007(Seismic) Power-limited,supervised circuitry.Maximum signaling current per cir- cuit: 2.5 amps special application, 250niA regulated. End-of-Line Agency Listings and Approvals Resistor::4.7k ohm, h watt.(P/N 71252 UL listed) for Class.B NAC; 9 Y 9 PP system-capable of 1.9 kQ - 22 kL2 ELR range. Refer to the Fire•Lite. The listings and approvals below apply to the basic ES-20OX control Device Compatibility Document for listed compatible devices. panel. In some cases, certain modules may not be listed by certain Two Programmable Relays-and One Fixed Trouble Relay: Con- approval agencies,or listing may be in process.Consult factory for lat- tact rating: 2.0 A @ 30 VDC:(resistive), 0.5 A @ 30 VAC (resistive). est listing status. Form-C relays,non-power-limited, non-supervised. ES-200X,ES-200XC,ES-20OXI Cabinet Specifications - • UL:S624 • FM approved Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.72"(1.82 . CSFM:7165-0075:0500 cm.) deep. Backbox: 19.00"I(48.26.cm.) high x 16.65'.' (42.29 cm.) . FDNY:COA#2021-TIVICOAP-009618-AMD wide x 5.25"(13.34 cm.)deep.Trim Ring(TR-CE):22.00"(55.88 cm.) high x 19.65"(49.91 cm.)wide. ES-200XP • ETL:5017286 Shipping Specifications • CSFM:7165-0075:0511 Weight:26.9 Ibs. (12.20 kg.) Dimensions: 20.00 (50.80 cm.) high x '22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. Temperature.and Humidity Ranges This system meets NFPA requirements for operation at 0—490C/32— 120°F and at a relative humidity 93% t 2% RH (noncondensing) at 32°C t 2°C (90°F t 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity.Therefore,it is recommended-that:this system and its peripherals be installed in an -environment with a normal room temperature of 15--27°C/60—80°F. InnovalrFlexTm and LiteSpeedTM are trademarks and AlarmNet®, Fire-Lite@ Alarms, SWIFT@, and System Sensor@ are registered trademarks of Honeywell International Inc. AT&T@ is a registered trademark of the AT&T Properties, L.P.Verizon@ is a registered trademark of Verizon Trademark Services LLC. Microsoft@ and Windows@ are registered trademarks of the Microsoft Corporation. ©2023 by Honeywell International Inc.All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. IS0. 9001 We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. BYCII<MINC 8 MANIFAB BIND QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:USA www.firelite.com Page 4 of 4—DF-60957:13 3/27/2623 r •% DF-520130•E-100 13G-12LX Flf'e•LITeWarms Addressable Manual Pull Station by Honeywell Addressable Devices General. The Fire-Lite BG-12LX is'a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station.This leads fire personnel'quickly to the location of the alarm. Features PUSH IN • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station,flashes in normal operation and latches steady red when in alarm. • Handle latches in'down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surfabe mounted (with SB-10 or SB-1/0) or semi- flush mounted. Semi-flush .mount to a standard single-. gang,double-garig,or 4" (10.16 cm)square electrical box. • Smooth dual-action design. N • Meets ADAAG controls and operating mechanisms guide- a.lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. usually needed for semi-flush mounting with 4" (10.16 cm)or Attractive shape and textured finish. double-gang boxes(not with single-gang boxes). • Key reset. Includes Braille text on station handle. Operation • • Optional trim ring.(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position. Once latched,the word"ACTT- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data.to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 — • Shipping Welghi:9.6 oz. (272.15 g) 99 and MS-92000DLS, 1 —50 for MS-9050UD). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 NA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors jn a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The BG-12LX will mount semi-flush into a single-gang,double- ing instructions provided on the cover. The word FIRE shall gang,or standard 4"(10.16 cm)square electrical outlet box,or appear on the front of the stations in white letters, 1.00 inches will surface mount to the model SB-10 or SB-1/0 surface back- (2.54 cm) or larger. Stations shall be suitable for surface box. If the BG-12LX is being semi-flush mounted, then the mounting on matching backbox SB-10 or SB-I/O;or semi-flush optional trim ring (BG12TR) may be used. The BG12TR is mounting on a standard single-gang, double-gang, or 4"(10.16 cm) square electrical box, and shall be installed DF-52013:D•4/13/2012—Page 1 of 2 l y� within the iimits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual.:Stations shall be Underwriters Laboratories listed. Manual stations shallconnect.with two wires to one of•thb con trol panei-SLC loops: The manual station shall, on.command from-the control panel;send data to-the panel representing the- state.of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information , BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10:Surface:backbox;metal: $B-UO:Surface'backbox;plastic. BG12TR:Optional trim ring. 17003:Keysi set of.two: Agency.Listings and:Approvals In some cases, certain modules.or applications may not be listed by certain approval agencies, or listing may be in pro- - cess..Consult.factory.for.latest:listing.status. . • UUULC Listed: S711-(listed for-Canadian-and non-Cana- dian applications'. • MEA:67-02-E. CSFM:.7150-0076:0184. • FM Approved. Patented:-U.S: Patent No.-D428,351; 6,380,846; 61314,772; 6,632,108.. I FireLite®Alarms®is a registered trademark of Honeywell.International Inc. ©2012'by Honeywell International Inc.Alf.rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation-purposes. IS010011" We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. - M1111IaINO aMAMMCMN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made:in the U.S.A. For more information,contact Fire-Lite Alarms:-Phone:(800)627-3473;FAX:.(877):6994105. www.firelite.com Page 2 of 2—'DF-52013:13 r 4/13/2012 i DF-61010:C SD365 Series Addressable Photoelectric Smoke Detectors OR MLITUALarms by :Honeywell Addressable Devices The Fire•Lite@ Alarms SD365(A), SD365R(A), and SD365HT(A) intelligent plug-in smoke, detectors are designed for both perfor- mance and aesthetics, and:are direct replacements for the SD355 Series. A new modern,•sleek,.contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more strin- gent code standards. - Exclusively for use with Fire•Lite's addressable fire alarm control �f r panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary,decimal address switches,provid- ing exact detector location for emergency personnel to quickly locate y a fire during its.early stages,potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor �,¢ t �/ 77777 light to provide a local,visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature ' thermal sensing on the SD365T(A)and a remote test capable detec- tor on the.SD365R(A) for',use with DNR(A)/DNRW duct smoke detector housings. Features • Plugs into separate base for ease of installation and maintenance SLC LOOP: • Separate base allows interchange of photoelectric,ionization and • Two-wire SLC loop connection thermal sensors • Unit uses base for wiring. OPTIONS: • Compatible with LiteSpeedTm and CLIP protocol systems Optional relay,isolator,and sounder bases • Stable communication technique with noise,immunity Installation ADDRESSING: , SD365 Series plug-in intelligent smoke detectors use a detachable • Addressable by device base to simplify installation, service and maintenance. Installation • Rotary,decimal,addressing instructions are shipped with each detector. (Refer to the Fire•Lite panel manuals for device capacity.) Mount detector base(all base types)on an electrical backbox which ARCHITECTURE is at least 1.5" (3.81 cm) deep. For a chart of.compatible junction • Sleek,low-profile,stylish:design boxes,see DF-60059. • Unique single-source design to respond quickly and dependably NOTE:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps"or branches are to.a broad range of fires- permitted for Class`B"wiring only. • Integral communications and built-in device-type identification When using relay or sounder bases, consult the 1300(A) installation • Built-in tamper resistant feature sheet 156=3626 for device limitations between isolator modules and isola- tor bases. • Remote test feature from;the panel • Walk test with address display(an address on 121 will,blink the Construction detector LED: 127[pause]-1(LiteSpeed systems only) -These detectors are constructed of fire-resistant plastic.The SD365 • Built-in functional test switch activated by external magnet Series plug-in intelligent smoke detectors are designed to commer- • Removable cover and insect-resistant screen .for simple field cial standards and offer an attractive appearance. cleaning • Expanded color options Operation OPERATION: Each 80365 Series detector uses one of the panel's addresses (total limit is panel dependent)on the Fire•Lite Signaling Line Circuit • Designed to meet UL 268 7th Edition (SLC).It responds to,regular polls from the control panel and reports • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- its type and the status. If it receives a test command from the panel old level (or a local magnet test), it stimulates its electronics and reports an • LED"blinks"when the-unit is polled (communicating with the fire alarm. It blinks its LEDs when polled and turns the LEDs on when panel)and latches in alarm. commanded by the panel. The SD365 Series offers features and Low standby current performance that represent the latest in smoke detector technology. • Detector Sensitivity Test MECHANICALSr Y • Sealed against,back pressure Each detector can have its sensitivity tested(required per NFPA 72, • SEMS screws for wiring of the separate base Chapter 14 on Inspection, Testing and Maintenance)when installed/ • Designed for direct-surface or electrical-box mounting connected-to an Fire•Lite addressable fire alarm control panel.The results of the-sensitivity test can be printed for record keeping. DF-61010:C•5/28/2020—Page 1 of 3 i Idk Product Line Information B200SA-WH:Same as B200S-WH, ULC listing NOTE."--IV"suffix indicates CLIP and LiteSpeed device. ' B200SA-IV:Same as B200S-IV,ULC listing NOTE.`A"suffix indicates Canadian version. B200SCOA-WH: White, Intelligent, programmable sounder base in in SD365:White,low-profile Aelligent photoelectric sensor,LiteSpeed Se91es detector ap(repl coat ons Canada for ULC applications with CO only SD365A•Same as SD365 but with ULC listing B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO SD365-IV: Ivory,low-profile intelligent photoelectric sensor Series detector applications, ULC listing SD365A-IV:Same as SD365-IV but with ULC listing B2008-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- SD365T:White,same as SD365 but includes a built-in 135OF(57°C) 10% with a square wave or its equivalent; designed to meet the fixed-temperature thermal device, LiteSpeed only NFPA 72 sleeping space requirement.(CSFM:7300-1653.0238) SD365TA:Same as SD360 but with ULC listing B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable SD365T-IV: Ivory, same as SD365T but includes a built-in 1350F sounder base. Produces a fundamental frequency of 520 Hz +/- (57°C)fixed-temperature thermal device 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) SD365TA-IV:Same as SD365T-IV but with ULC listing B200SR-WH:White, Intelligent sounder base capable of producing SD365R: White, low-profilei intelligent photoelectric sensor, remote sound output with:ANSI Temporal 3 or continuous tone.Intended for test capable,-for use with DI R/DNRW,LiteSpeed only retrofit applications. (CSFM:7300-1653:0213) SD365RA: Same as SD365R but with ULC listing, for use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA sound output with ANSI Temporal 3 or continuous tone.Intended for SD365R-IV:Ivory,low-profile intelligent photoelectric sensor,remote retrofit applications. (CSFM:7300-1653:0213) test capable,for use with DNR/DNRW B200SRA-WH:Same as B200SR-WH with,ULC listing SD365RA-IV:Same as SD365R-IV but with ULC listing,for use with B200SRA-IV:Same as B200SR-IV in Ivory color, ULC listing DNRA B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NOTE:For details on intelligent bases,see DF-60059. NFPA 72 sleeping space requirement. Intended for retrofit applica- B300-6:White,6"base,standard flanged low-profile mounting base tions.(CSFM:7300-1653.0238) (CSFM.7300-1653.0109) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300-6-IV:, Ivory,6" base, standard, flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base(CSFM:7300-1653,0109) 10% with a square wave or its equivalent; designed to meet the B300A-6:Same as 6300 6,:ULC listed NFPA 72 sleeping space requirement. Intended for retrofit applica- tions.(CSFM:7300-1653.0238) B30OA-6-IV: Ivory, 6" standard flanged low-profile mounting base,ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6,package contains 10 TR300:White, replacement flange for B210LP(A)base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for 6210LP(A)base base. UUULC listed(CSFM:7300-1653.0109) RA100Z(A): Remote LED annunciator.3-32 VDC.Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box.For use with B501(A)and B300-6(A). UUULC listed(CSFM:7300-1653:0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting M02-09-00:Test magnet with telescoping handle base. UUULC listed(CSFM:7300-1653:0109) CK300:Color Kit(includes cover and trim ring),white, 10-pack 113501-WHITE-BP:Bulk pack of B501-WHITE contains 10 CK300-IV:Color Kit(includes cover and trim ring),ivory, 10-pack 1132241RB-WH:White,relay 0ase(CSFM:7300-1653.0216) CK300-BL:Color Kit(includes cover and trim ring),black, 10-pack B224RB-IV: Ivory,relay base(CSFM:7300-1653:0216) B224RBA-WH:White,relay base,ULC listing B224RBA-l11: Ivory, relay base, ULC listing B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV: Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White,isolator detector base, ULC listing 13224BIA-IV Ivory isolator detector base,ULC listing B200S-WH:White,Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSITemporal 4,continuous tone,marching tone,and custom tone. Uses LiteSpeed protocol. (CSFM:7300-1653:0213) B20OS-IV: Ivory, Intelligent!addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. .Uses LiteSpeed protocol. (CSFM:7300-1653.0213) 'Page 2 of 3—DF-61010:C•5/28/2020 SYSTEM: SPECIFICATIONS .Sensitivity: Listings and Approvals • UL Applications:0:5%to'4.0%:per foot obscuration. Listings and approvals below applyto the SD365 Series detectors. • ULC Applications:0.5%to.3.5%per foot obscuration . In some.-cases, certain modules may, not be listed by certain Size:2.0"(51mm)high;base determines diameter approval agencies, or.listing maybe-in process. Consult factory for latest listing status. =B300=ti:6.1"(15.6,cm);diameter. B501:=4"(10:2 cm)diameter • UUULC Listing-.S1059 For a complete list of detector bases see DF-66983 FM Approved Shipping weight:3.4 oz.(95 g) • CSFM:7272-0075:0502 Operating temperature range: . • .-SD365:32°F to-122°F'(0°C to.50°C). .• .SD365T Series:-320F to i00°F.(0°C to 380C) • SD365R Series installedin a DNR/DN.RW, -40F to 158OF (-20°C .to 70°C) UUULC Listed Velocity,Range: 0-4000 ft/mih. (1219.2 m/mih.); suitable for installation in ducts Relative humidity: 10%--93%non-condensing Thermal ratings:fixed-temperature set point 1350F(570C);rate-of rise detection 150F(8.3°C)per minute;'high:temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage:range: 15-.32 volts:DC'peak Standby current(max.avg):200pA-@ 24 VDC'(o:ne communica- tion every 5 seconds with LED enabled) Max current:4.5 mA'@ 241VDC("ON") DETECTOR SPACING AND'APPLICATIONS Fire•Lite.recommends.spacing detectors in compliance-with NFPA 72. In low airflow applications with smooth ceilingi_space detectors 30 feet(9.1m). For specific information regarding detector spacing;_ placement, and special applications refer-to NFPA.72. A:System Smoke Detector-Applicatior),Guide,document SPAG91, is available- at www.systemse-nsor.com. LiteSpeedTm is-a trademark, and..Fire•LiteO Alarms and System SensorW are registered trademarks of:Honeywell International.Inc. ©2020 by Honeywell.International Inc.All rights reserved.Unauthorized use of this. document is strictly prohibited. This document is not intended to be used for installation.purposes: We.try to keep our product information.up-to-date and accurate. ISO. 900.1 We cannot cover.all specific applications or anticipate all requirements. - All specifications are subject to change without notice. :BVIINEaINi BINANIFACi1NIN6' • :QUALITY A Y S T E M S For more information,contact Fire•Lite Alarms:Phone:(800)627-347a,FAK(877)699-4105. •Country of Origin:Mexico www.firelite.com Page 3 of 3—DF-61010:C•5/28/2020 • Universal full event sole&dual path cellular&/or IP commercial UL and NFPA 72 Fire Code-Compliant,the StarLink Series fire alarm reporting from;any panel brand,virtually anywhere Wireless Commercial Fire Alarm Sole Path&Dual Path nationwide Communicators provide universal support for any brand • Code-compliant,replaces,2 POTS lines per FACP saves thousands 12V to 24V fire alarm control panel,reporting in Contact of dollars per year over the leased landlines ID and 4/2. With broadest LTE coverage footprint,Verizon or AT&T,using proven StarLink circuitry,they are also • Supports 12V-24V control panels and FACPs that communicate using available in locking metal models.All provide the most Contact ID and 4/2(such as on legacy panels),as primary or backup economical solution for easy,versatile installation.Also • Full data Reporting to any Central Station nationwide,via choice regional compliances,i.e.,CSFM,NYCFD,LAFD and more. of LTE Networks,Verizon®.or AT&T®. Communicate critical life Easy,Universal Installation at Every Application;Panel- and safety alarm reports on LTE(Long Term Evolution)10+year life,cyber-protected multi-billion dollar cellular network,for Powered Technology .StarLink Fire Communications are maximum life safety&liability protection. easily connected to any panel or Fire Alarm Control Panel (FACP)standardly operating between 12V and 24V.Flexible • Proven to work even where other's won't-using Signal BoostTm in any application,StarLink Fire also comes in standard,or &twin dual diversity antennas- Max.signal acquisition&null models in metal housings,with code-compliant supervision, avoidance(receives signals'simultaneously on both antennas) and choice of power options,Panel-Powered Technology" • Easiest installation,powered by panel,NO extra power supply, (powered by the panel),or direct-connect 120VAC models. NO extra conduit.(Excludes Direct AC-Powered "-PS"models,with Signal Boost circuitry&dual diversity antennae for transformer option.)t maximum signal acquisition&null avoidance,receiving • Dual Path Cellular/IP Models Save Time&Money-Uniquely signals simultaneously on both antennae. including 4 programmable EOLR zone inputs;2 Form C Relay outputs Flexible Performance&Reporting Options.StarLink Fire (no extra supervision modules to buy or install);plus,2 Telephone- provides full data reporting, in sole and'dual path,as a style jacks for easy FACP-connection.Self-supervised on 4 wires. primary or backup,to any central station of your choice, • Preactivated to ensure communications-saves time and labor onsite without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes • LED Status/Trouble Indicators 3 Radio Status LED Indicators and requirements,with supervisory check-ins from 200 (visible from outside standard model housing)-Green,Signal seconds,to 5 minutes;and/or from.1 to 6 hours.The units Strength;Amber-Busy/Activation;Red-Trouble(4 additional LEDs, are very easily activated, plans and options are selected, not visible,for network status&troubleshooting). Power LED and 24/7 account management is provided all through indicator viewable on outer metal enclosure models. www.napcocomnet.com. • Over-the-Air Upgradable Communicator Firmware.Remote ability for critical/mandatory updates,without a truck-roll • Cost-saving models and plans for any code requirement. Napco StarLink Universal Fire Alarm Dramatic savings over monthly dedicated landline charges. Communicators • Sole Path Cellular and Dual Path Cellular&/or IP Models ( � • Choice of LTE Networks,Verizon or AT&T models • Choice of plans(varies by model)-check-ins from 200 seconds to 5-minutes,and from 1 hour,up to 6 hours for N�Cew • dual path Patented Signal BoosVm and Dual Diversity Antennae r for maximum signal acquisition&null avoidance,receiving signals simultaneously on both antennae • Money-saving Tradeup incentive credit for security professionals,on new or retrofit fire systems,i.e.,tradeup missing/retired POTS lines,old radios&networks or new installations • Bonus:Full High-Speed Napco Panel remote uploading/ downloading • COMPLIANCES:NFPA 72 Editions:2019,2016,2013,2010, 2007;UL 864,10th Ed.,UL1610,UL985,UL1023,NYCFD; star nk CSFM;LAFD � connected by � �\ AT&T verizon✓ NFPA Code-compliant standard or metal models on choice of Verizon orAT&T LTE networks. connemo oy Model Ordering & Specifications vedzon,/ u AT&T Unique Onboard Other Power LTE WIN Electrical Input Network Cell IP Option- Labor/Cost-Saver Patin Inputs Input Ratings Outputs Output Ratings Supply Features (option)r r SOLE PATH SLE•LTEA FIRE AT&T Yes No No Panel-Powered Tech'y:TM Input Voltage/Input IN1:9-25VDOMaxinput , Open Collector Outputs Max PGM2 Current:1 OV=90mA; IN1,IN2, current 2mAIN2,IN3: PGM2 3V when active,Max 25V , ' 12.25V=71mA, ,IN3 9.25VDC Max'input PGM3 When not active.Max current SLE-LTEV•FIRE Verizonn Yes !No No 200mA peak during currentl.2mA 24mA@25V transmissions DUALPATH 2 TelCo jacks for EZ panel-PoweredTech'y:TM OUT1,OUT2;Dry Contact,Form SLE-LTEAI•FIRE AT&T Yes Yes Yes FACP Connect;4 IN1:.9.25VOC Max. InputVoltage:10.25VDC: C Relay,30VAC/DC,500mA ProgrammableEOLR IN1,IN2, inputcurrent2mA OUT1, Input Current: 162mA Max PGM3:Open Collector zone inputs;2 Form C IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Relay outputs(avoids to I OOmA standby; IN5 9-25VDC Max input PGM3 Outputs Max 3Vwhen alive, SLE-LTEVI-FIRE Verizon Yes Yes Yes 300mA peak during Max 25V when active.Max regtforsupervision transmissions current1.2mA current 24mA@25V module r SOLE PATH SLE•LTEA-CFB AT&T Yes No No Panel-PoweredTech'yt' Input Voltage/Input 1N1:9.25VDC Max input Open Collector Outputs Max PGM1 Current: 10V=90mA; IN1,IN2, current 2mA IN2,IN3: , 3V when active,Max 25V 12-25V=71 mA, IN3 9.25VDC Max in ut PGM2, when not active.Max current SLE-LTEV-CFB Verizon Yes No No 200mA peak during current 1.2mA PGM3 24mA@ 25V transmissions SLE-LTEA-CFB-PS AT&T Yes No No Direct AC-Powered:Input IN1:9-25VDC Max input Open Collector Outputs Max Transformer Voltage:120VAC nominal PGM1', IN1;IN2, current2mAIN2,IN3: 3Vwhen active,Max 25Uwhen (TRF12 ' Input Current:150mA PGM2, max;maximum charging IN3 9-25VDC Max input PGM3 notattive.Maaimumcurrent 16VAC,20UA SLE-LTEWCFB-PS Verizon Yes No No current:200mA current l.2mA 24mA@25V transformer) DUAL PATH 2 TelCo jacks for EZ Panel•PoweredTech'y:TM OUTI,OUT2:Dry Contact,Form SLE-LTEAI-CFB AT&T Yes Yes Yes FACP Connect;4 IN1:9c25VDC Max InputVoltage:10-25VDC: C Relay,30VAGDC,SOOmA Programmable EOLR IN1,IN2, inputcurrent2mA OUT1, Input Current: 162MA Max PGM3:Open Collector zone inputs;2 Form C IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Relay outputs(avoids to 100mAstandby; IN5 9-25VDC Max input PGM3 Outputs Max 3Vwhen active, 300mApeakduring Max rrVwhenactive.Max SLE•LTEVI•CFB Verizon Yes Yes Yes regt for supervision transmissions turrentl.2mA current 24mA@25V module) 2TelCojacksforE2' ' r SLE-LTEAI-CFBPS AT&T Yes Yes Yes FACP Connect;4' Direct AC-Powered:Input IN1:9-25VDC Max CRela,30VA IDC,5ContacOOmA ProgrammableEOLR' Voltage:1ZOVAC nominal IN1,IN2, inputcurrent2mA OUT1, C'Relay,30VAC(DC,500mA Transformer zone inputs;2 Form C InputCurrent:200mA IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Max PGM3:Open Collector (TRF12 Relay outputs(avoids max;maximum charging IN5 9-25VDC Max input PGM3 Outputs Max 3Vwhen active, 16VAC,20VA SLE-LTEVI-CFBPS Verizon Yes Yes Yes regtforsupervision current:200r0A, currentl.2mA Max 25Vwhen active.Max transformer) orsup r A " current 24mA@25V moduACCESSORIES: e SLE-VUIFI-MODULE Optionally connects supported dual path models to FIYeLInk'' Integrated Fire Alarm Control Internet via WiFi,eliminating Ethernet cable connection.Requires 7AH batty. Panel W/StarLink Fire LTE Built In g ('"See details W12191); 2630A SLE-ANTEXT75 Optional extended range omni.antenna w/75'cable, FL-32FACP-LTEV Firewolf 8 Zone 24V Conventional premium low-loss cable&full mounting hardware&ground fault isolation ' Commercial Fire Alarm Control Panel with onboard mounting plate StarLink Fire®Sole Path,Verizon LTE Cellular SLE-ANTEXT50 As above,with 50'cable Alarm Communicator amp, p menu.-driven LCD annunciator,w/4amp,24V power supply:. SLE-ANTEXT30 As above,with 30'cable Optionally expandable up to32 points/zones via TRF12 O tional Plu in AC Transformer,16.5V/20VA(use commercial addressable,wireless or conventional p gay—s_ J fire devices(2 onboard NACs providing up is subject to Iota(code compliance)t :. �: to 4A notification power).Locking,metal red enclosure,(surface or flush mount?removable Free Commercial Fire LTE Tradeup Trifold- 16'x17"door w/14.25"xl6"base.Houses,•16Ah Brochures/Mailers/Stuffers(A747) '� batterybackup n StarLink Fire 333 Bayview Ave.,Amityville,NY 11701 • 1-800-645-9445 • www.napcosecurity.com Note:Always consult technical manual and/or AHJ forcompliance requirements for your area/appllication.StarLink,StarLink Fire,FireLink,Signal Boost,Panel-Powered Technology,Gemini&Gemini Commercial are trademarks of Napco.AT&T,Vernon,LTE,etc.are trademarks of their respective companies.'StarLink offers full data coverage in US from virtually all panel brands reponing in Contact ID or 4/2.tt For Panel-Powered technology,regulated auxiliary power outputs are required on Listed FACP."Add 40mA to input current&Standby Battery requirement.tWhere permitted by AHJ;requires conduit.;For full details on the StarLink tradeup incentive see online under http://www.napcosecuril.com/starlink/starlink4gupgrade/tPromo subject to change w/o prior notice.LTE lifespan claims are based on those of carriers. ©NAPCO,NAPCOSecurityTechnologies Inc.(NASDAQ:NSSC) A734A2019.8 DAA 13 0 EXI5TINO TO REMAIN PROP05ED INTERIOR ALTERATION DiGiovanni & Associates Architects 3 HR RATED FIRE WALL b" METAL STUDS ® 16" O/G W/(5) LAYERS 5/6" TYPE "X" GYP. BD 26 preston avenue EACH 51DE (TYPICAL) HEAT PUMP UL DESIGN #U435 Sea cliff, ny 11579 (516) 671 - 3624 Daa93@msn.com GO HT GO MEGH �- 24-I10 /5 SELF STORAGE SELF STORAGE SELF STORAGE SELF STORAGE -�'� �Sf3Eo EXISTING 3 HR RATED FIRE WALL 2,1"10 SF/500=5p /5 �— 2,160 SF/500=5p /5 /5 2,110 SF/5X=5p /5 2,330 5F/5xz5p f9�c' RC © EXISTING UL DESIGN U435 — CLIMATE CONTROLLED — _ — — — CLIMATE CONTROLLED — _ — — CLIMATE CONTROLLED — — — — CLIMATE CONTROLLED — Q �O A �''/O y�� — in HT "8169 °F NEW'i - - � --- - - - - --------- - - � - - - - - - - - -- -- - - -- - - - - ----� - - - - 1551JED I I I STORAGE AREA 5,000 5P/500=bp UNHEATED I I - O o - - - - — - - - - � - - - - - - —� — - - - - - - - - � - - - - - - I II III — T — — -------- --------- -----T — — — — — — — — — T — — -- -------- — — — — — — — — HT O FL L—j t Lj GO O- GO GO GO 0— ❑ P © I © MEGH R HEAT PUMP 3 HR RATED FIRE WALL b" METAL STUDS ® 16" 0/6 W/(3) LAYERS 5/8" TYPE "X" 4 GYP. BD EACH 51DE (TYP) UL DE51ON #U435 Iq8'-0" EXISTING METAL SIDING (TYP ALL EXTERIOR WALL5) I FLOOR PLAN GOXLANE__ _ �`� E3UILDING52 I/8" = I'-O" ,�.�.ev,ou..s�� �o.oaarAr.srTu R ;h r 5 41°0I'00'E 33186' . NCC Fl 5 46°2450'E 413.19' � rW+" pro g IT r y rw rem"_ X A PROJECT LOCATI \ t ewm ! O Pa NULL \ �1 LOCATION N(M kr 4) \ 'a w +T EUILDIN5I y 4 ,noo a EXI5TIN6 I STORY EXISTING I ST t rr•e_w o $ STORAGE BUILDING I / \ Ilb�eI SELF STORAGE BUILDING FIRE ALARM NOTES: _ ` ~�x '°°' s ou 5 I, ,�Gwae 5b $ I I'b8O ,! I L/ \ ✓�J 6p Ocb 6p 5-I,Gonst 1 51.11 1 L � � ~�R � (cYy b"„dMg1 f!el=5'15 ( bulidlnc�R el•5'1S \ �' pe• � rwra � � riled under separate cpplkatlon I. FIRE ALARM AND SMOKE DETECTION SYSTEM SHALL \ COMPLY WITH MANUFACTURERS INSTALLATION 5PEGIFI(ATIONS. X '°' >< \ \ LEGEND STATE AND LOCAL BUILDING CODES N.F.P.A. Z2 AND ALL """"�""" "^"` a m R E V 1 5 1 O N 5 AGENGIE5 HAVING JURISDICTION. \ \ FIRE ALARM AND SMOKE DETECTION SYSTEM WO.W '°°°' SHALL BE "FIRELITE" OR APPROVED EQUAL, 2. CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUITS. �O ,-�T�,,,r ° BUILDING s 'a THESE M'A*ARE AN MTR KW OF SERVICE AND ARE THE > BUILDING 4 �. •, ewTORAI 1 STORY PROPERTY OF THE ARCHITECT.INFRIN67DOTS NULL BE OUTLET BOXES, JUNCTION BOXES, CABINETS, ETC. FOR Y 6 EXISTING 1 STORY SELF STORAGE BUILDING ZONED AND ALARMED SYSTEM. �� ,� SELF STORAGE BwLDINb �,�er I /` .� \ ,� A COMPLETE OPERATIONAL INSTALLATION. w00 POSTS L� x x ^� ■ ';° $ zh. �� I $ rl bOO of6p �� 1 U \ �^ PRASEGUTED. (dry bvlldi"C�►F el R 5l5 SYMBOL DE5GRIPTION MODEL NO. 3. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALLg ®^� "ed „r` \ CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND FIRE ALARM SYSTEM EQUIPMENT WITH WORK OF 0 4" i \ p DIMEN510N5 AND SHALL BE RE51FON5113LE FOR FIELD FIT J AND QUANTITY OF WORK.NO ALLOWANCE SHALL BE MADE OTHER TRADES PRIOR TO INSTALLATION. a L�A'E � \ 3 ON THE BEHALF OF THE CONTRACTOR FOR ANY ERROR OR r FAGP FIRE ALARM CONTROL PANEL E5-2OOX - FIRE LITE §I LOCATED IN DETACHED OFFICE BLDG (ADDRE55ABLE) 4. ALL MANUAL PULL STATIONS SHALL BE MOUNTED 5 LA�NKEo °�ry° NEGLECT ON HIS PART. WITH THE HANDLE 45" ABOVE FINISHED FLOOR. I r 7 P 1100 PULL BOX BG12LX - FIRE LITE a - J C ` „ �a BUILDING 5 BUILDING 6 I / (ADDRE55ABLE) 5. ALL VISUAL DEVICES SHALL BE MOUNTED 50 ABOVE dr „�, ,,, EX15TINS I STORY EXISTING I STORY SELF STORAGE BUILDING SELF STORAGE BJItDINb Stonewall FINISHED FLOOR OR b BELOW FINISHED CEILING �8 =l) g� �I $ ( 13000"r $ 13pOOs! L/ \ HT FIRE LITE 350HT WHICHEVER 15 LOWER. d " o N °03' �33S2' .r I% GonsDGas2'' 8 0°a sI,G°nstaassZb Iq0° FIXED TEMP. HEAT DETECTOR = rlled 4m"„*amto w'PIkatw" pea�'Isep"to CmIk4tTom \ O / 60i RI.Y°YL (ADDRE55ABLE) I ro` $ / \ 6. CONTRACTOR SHALL OBTAIN ALL RE \ Storage llc QUIRED APPROVALSAND PERMITS PRIOR TO START OF WORK AND OBTAIN uw RL.Q rtr rA1..6LG g \ \ H/S HORN d STROBE -24VDG FIRE LITE 51ON-OFF FROM ALL AGENGIE5 HAVING JURISDICTION y _ \ (5Y5TEM 5EN50R) UPON COMPLETION. fill Dx s? 11900 Oregon Road 5 SMOKE DETECTOR FIRE LITE 50365 1. A FACTORY TRAINED TECHNICIAN SHALL 5UPERV15E N 46°03'00'W 560 Cutcho ue , NY (ADDRE55ABLE) THE FINAL CONNECTIONS AND SHALL TEST AND g ADJUST ALL EQUIPMENT UPON COMPLETION. GO CARBON MONOXIDE DETECTOR 10 YEAR BATTERY LOCAL ALARM ONLY b. SYSTEM SHALL BE CENTRAL STATION MONITORED via 51 TE PLAN FLOOR I$ 51 TE CELLULAR RADIO COMMUNICATOR f ❑R HVAG SHUT DOWN FIRELITE M300 -0 1" = 60' PLANS SCHEDULES q. HVAG SHUTDOWN OCCURS DURING GENERAL ALARM CONDITION GOXS LANE (ADDRE55ABLE) MULBERRY 5T. / Q � PROJECT LOCATION 4. AIR Am a A TUTHILL a 8/6/24 ROAD W DATE (L a +ERG KE r MAP A5 NOTED 5GALE DEPOT LANE VIRANM BY GHEC.ICED BY dd