Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50494-Z
�oy't.of s°uryo`Q Town of Southold * * P.O. Box 1179 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45955 Date: 02/06/2025 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ADDITION AND ALTERATION Location of Property: 2915 Stanley Rd Mattituck, NY 11952 Sec/Block/Lot: 106.-8-71 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/26/2024 Pursuant to which Building Permit No. 50494 and dated: 04/01/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built' finished basement including recreation room, wine cellar, wet bar and bathroom to an existing single family dwelling as applied for. The certificate is issued to: Lauren Fein , Ross Fein Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50494 12/18/2024 PLUMBERS CERTIFICATION: Jeff A. Zahn 01/29/2025 fA,. L.0" Au orize S' na ure �'of SOUryo TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE �o���UUNiY.N� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50494 Date: 04/01/2024 Permission is hereby granted to: Lauren Fein 416 Kent Ave Apt 1707 Brooklyn, NY 11249 To: Legalize "as built' finished basement to an existing single-family dwelling as applied for. Additional information may be required Am'ene 1d 0 3.24for�reconfig�u�"ra �ongobasernent, ��ut w ooms•andxdisconnect� Premises Located at: 2915 Stanley Rd, Mattituck, NY 11952 SCTM# 106:S-71 Pursuant to application dated 02/26/2024 and approved by the Building Inspector. To expire on 10/01/2025. Contractors: Required Inspections: Fees: AS BUILT-SINGLE FAMILY ADDITION/ALTERATION $1,599.00 CO-ALTERATION TO DWELLING $100.00 ELECTRIC $350.00 Total $2,049.00 Building Inspector p�sufFot �oG TOWN OF SOUTHOLD ��- BUILDING DEPARTMENT y x . TOWN CLERK'S OFFICE o . g SOUTHOLD, NY' Ail �pp� BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50494 Date: 4/1/2024 Permission is hereby granted to: Fein, Lauren 416 Kent Ave Apt 1707 Brooklyn, NY 11249 To: Legalize "as built' finished basement to an existing single-family dwelling as applied for. Additional information may be required. At premises located at: 2915 Stanley Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 106.-8-71 Pursuant to application dated 2/26/2024 and approved by the Building Inspector. To expire on 10/1/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $1,599.00 CO-ALTERATION TO DWELLING $100.00 Total: $1,699.00 Building Inspector oF so�ryQl � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 1 1 97 1-0959 �Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lauren Fein Address: 2915 Stanley Rd City: Mattituck St: NY Zip: 11952 Building Permit#: 50494 Section: 106 Block: 8 Lot: 71 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Indoor Basement I✓ Service I✓ Solar Outdoor 1st Floor r Pool r Spa r Renovation 2nd Floor Hot Tub r Generator r Survey Attic r Garage Battery Storage r INVENTORY Service 1 ph _ rV— Heat Duplec Recpt 9 Ceiling Fixtures Bath Exhaust Fan Service 3 ph r Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 19 CO Detectors Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights 40' Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4 4'LED Exit Fixtures Other Equipment: Mini Fridge, Ice Maker, Mini Split, 200A Panel 40 Circuit/ 35 Used Notes: " AS BUILT NO VISUAL DEFECTS " Finished Basement & Service Inspector Signature: X Date: December 18, 2024 Sean Devlin Electrical Inspector Sean.deviin((z�.town.southold.ny.us 2915Stan IeyBasement&Service # TO WN WN OF SOUTHOLD BUILDING DEPT. �o .0oorm 1 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [: ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE .& CHIMNEY [ ] -FIRE SAFETY INSPECTION [ . ] FIRE RESISTANT CONSTRUCTION [ .] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ NTAL EMARKS: 4s- -st/fo- �nZleevaA C Lg 31 470 -A,10CA rouldMCI �- r In Gee r4c.rinC. [r P, [do +� k k4- [A t6j-d lc J� �C�s Q� �J . j C/A nl. W_ -cl 0JA ��2 1) 4-r(p�� �nL 1 . �n S f'�_ 0 DATE INSPECTOR - .l #�pfSOUtyO# � � �-� � �-► 2� r � �-� � y TOWN OF SOUTHOLD BUILDING DEPT. o�m�a� 631-765-1802 2 INSPECTION [ ] -FOUNDATION 1 ST/ REBAR . [ ] ROUGH PLBG. ] FOUNDATION 2ND [ ] INSULATION/CAULKING ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [. ]-.FIRE SAFETY INSPECTION [ _ ] FIRE RESISTANT CONSTRUCTION .. [ . ] FIRE-RESISTANT PENETRATION -[ ] ELECTRICAL (ROUGH) j ] ELECTRICAL (FINAL) [ ] ,CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: tk ► ��'� Vv rl e /-f p C G Gn taw Dam 14 ^� er wr aD DATE INSPECTOR q so �� yo # TOWN OF SOUTHOLD BUILDING DEPT. °ycauim�� 631-765-1802 �,,nq INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ]. FOUNDATION 2ND [ ] NSULATION/CAULKING [ ] K. FRAMING /STRAPPING [ FINAL P✓1 - a �va!p- FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:%-. , 4 r�Dv (rt-1) �� wirw (R) IhKAvon., �L DATE INSPECTOR oF souryOlo �Q I vI # # TOWN. OF SO.UTHOLD BUILDING DEPT. 631=765-1802 INSPECTION ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 4,5'- (`?;'u z-T ��MM�- DATE � '� 2 INSPECTOR OF SOUTH°6 # # TOWN OF SOUT-HOLD BUILDING DEPT.. Mum��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/REBAR. j ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ylx<UL7AULKI NG FRAMING/STRAPPING [ .FINAL FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] -FIRE RESISTANT CONSTRUCTION . [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE.C/O , [ ]- RENTAL '�wc2 REMARKSEEZ DL vvwq- kl9!b A nn- k&�,va- wt I( caoo� 44, C 0 Uh/ 1 CUP DATE INSPECTOR L D ECEIVE JEFF A. ZAHN, A.I.A. ARCHITECT-PLANNER FEB 5 2025 Building Department Town of Southold January 29,2025 To: Town of Southold Building Ross Fein 2915 Stanley Rd. Mattituck NY 11952 1000-106-08-71 Pen-nit 50494 To Building Inspector John Jarski, An inspection was performed on January 15, 2025,I certify to the best of my knowledge that the existing plumbing was installed in current plumbing code,and I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. The owner installed the pool alarm per UL2017 photo attached. If you need any additional information,please contact my office. Best regards, Jeff A,Zahn AIA , ® � N�Cc: T. Cloughen file 215 ROANOKE AVENUE■RIVERHEAD, N.Y. 11901 ■631.727.0544 ■FAX:631.727.5335 a E C E 0 E F E B 5 2025 Building Department Town of Southold i 1 1. i 6 FLDINSPECTION REPORT DATE COMMENTS 0 FOUNDATION (IST) ---------------------------------- o col) FOUNDATION (2ND) O cn ROUGH FRAMING& PLUMBING C=X) INSULATION PER N.Y. STATE ENERGY CODE A -- Jo.Aj( FINAL ADDITIONAL COMMENTS � 1���=--P��1��%�o�- Gam- - s. g c -D 94 y_i 0 -lo-3-QL4 - ikyylllc VE Xu Pe-c. oS�FFotr�oGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT N Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ���,j PERMIT NO. 5 0 1 I 1 Building Inspector: JAV l J i J FEB 26 2024 Applications and forms must be filled out in their entirety.Incomplete , --y^^,•� },,.� applications will not be accepted. Where the Applicant is not the owner,an Owner's.Authorization form(Page 2)shall be completed. o 'n Date:02/13/24 OWNER(S)OF PROPERTY: Name:Ross Fein SCTM #1000-106-8-71 Project Address:2915 Stanley Rd., Mattituck, NY 11952 Phone#_954-260-4634„ Email:rossfein.11 @gmail.com Mailing Address:2915 Stanley_Rd.,„Mattituck, NY11952" CONTACT PERSON: Name:Timothy Cloughen Mailing Address:3 Manorview Way, Manoville, NY 11949 Phone#:631-255-7845 _ _ Email_tm_.cloughen@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Jeff A. Zahn Mailing Address:215 Roanoke Ave, Riverhead NY 11901 Phone#:631-727-0544 - Email:Jazcad msn.com CONTRACTOR INFORMATION: Name:NA Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther Maintain existing finished basement $ 10,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:Single Family Residence Intended use of property:Single Family Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to RHO this property? ❑Yes No IF YES, PROVIDE A COPY. B Check Box After Reading: The'owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter'236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210A5 of the New York State Penal Law: Application Submitted By(print name): Ross Fein ❑Authorized Agent BOwner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) TZ0-5-s- being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer, etc,) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 23 day of � �K04'R-Y 20 91' Notary Public RUTH ESTHER HERNAND PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC,SfATEOFNEWYO Registration No.OIHE&31033 (Where the applicant is not the owner) Qualified in New York County My Commission Expires v3—Z Z I, Ross Fein residing at 2915 Stanley Rd. Mattituck, NY 11952 do hereby authorize Timothy Cloughen to apply on my behalf to the Town of Southold Building Department for approval as described herein. /_-- z/Z.,q/z--,f. Owner's Signature Date Ross Fein Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector oy TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 w: Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ia mesh a-southoldtownny.gov— sea nda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: 04-25-2024 Company Name: N/A-As-built Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Ross Fein Address: 2915 Stanley Rd, Mattituck NY 11952 Cross Street: Path Thru Wood Phone No.: 954-260-4634 - Cell 631-255-7845 Bldg.Permit#: 50494 email: rossfein.11@gmail.com Tax Map District: 1000 Section: 106 Block: 8 Lot: 71 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Legalize As-built finished basement. Square Fo tage: loss Circle All That Apply: ,h5 f�4 Val Is job ready for inspection?: 17 YES ❑ NO ❑Rough In Q Final Do you need a Temp Certificate?: ❑ YES ❑✓ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y ✓ N Additional Information: ° PAYMENT DUE WITH APPLICATION Oq )(ec 0'7ca5 r,rxz-. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 ,>- Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 N� lameshasoutholdtownny.gov — seandasoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 04-25-2024 Company Name: N/A-As-built Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Ross Fein Address: 2915 Stanley Rd, Mattituck NY 11952 Cross Street: Path Thru Wood Phone No.: 954-260-4634 - Cell 631-255-7845 Bldg.Permit#: 50494 email: rossfein.11 @gmail.com Tax Map District: 1000 - Section: 106 Block: 8 Lot: 71 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Legalize As-built finished basement. Square Fo tage: 1099 Circle All That Apply: Is job ready for*inspection?.- 17 YES ❑ NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #-Underground Laterals 1 F12 0 H Frame Pole Work done on Service? Y W/ N Additional Information: PAYMENT DUE WITH APPLICATION /,y� Oct �aa II Ife.c a - p �(a 5 >�� 5 o4g4 PERMIT# !Address: Switches ,1 I-) Outlets GFI's I � ' Surface Sconces H H's � '"� I �� I UC Lts Fridge HW POOL Fans Mini Fr.j W/D Panel Pump t ce Air" Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps2Q,0 Have L,,� Used 7E�,_�' Sub Amps Have Used Comments C- 4 � ,J, Wav- Generated by REScheck-Web Software Compliance Certificate Project FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: Alteration Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 2915 STANLEY RD Ross Fein Jeff Zahn MATTITUCK, NY 11952 2915 STANLEY RD Jeff Zahn Architect MATTITUCK, NY 11952 215 Ronoake Ave 954-260-4634 Riverhead, NY 11901 rossfein.11@gmail.com 631-727-0544 jazcad@msn.com usingCompliance: Passes prescriptive requirements for alteration projects Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Prop.Gross Area Cavity Cont. Req. Prop. Perimeter Basement: Solid Concrete or Masonry Wall height: 7.0' 1,099 15.0 5.0 0.050 0.059 53 62 Depth below grade: 4.0' Insulation depth: 7.0' Door 3680: Solid Door(under 50%glazing) 20 0.280 0.320 6 6 Window: 2836:Vinyl Frame 7 0.280 0.320 2 2 SHGC: 0.26 Window: 2836:Vinyl Frame 7 0.280 0.320 2 2 SHGC: 0.26 Window: 2836:Vinyl Frame 7 0.280 0.320 2 2 SHGC: 0.26 Window: 2836:Vinyl Frame 7 0.280 0.320 2 2 SHGC: 0.26 Compliance Statement. The propoF d Fi��J � g des n�d�sci hed here is consistent with the building plans,specifications, and other calculations submitted with the r�,rFa pi'�tion.� �ep�`o�ost d building has been des' ned tom the 2018 IECC requirements in REScheck Version : REScheck e rir�i o� iy w�a 1at`e n( 'a, t ry require en is ed1 the R S heck Inspection Checklist. Jeff A. Zahn Onn ` ,r j 02-2&24 Name-Title n `ure Date 0. Project Notes: , Project Title: FEIN RESIDENC<� , � �?II ��IGiG; E :�t5tD BASEMENT Report date: 02/22/24 Data filename: �- '' f' Pagel of 9 FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT2915 STANLEY RD, MATTITUCK, NY 11952 Project Title: FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 2 of 9 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Sectwn Plans Veretl Feld Verrtied t Y # Pre Inspection/Plan ReWiew< ,, Value$K z Compl�ese ^, ra Comments/Assumptions Value 103.1, !Construction drawings and ❑Complies ;Requirement will bemeta 103.2 documentation demonstrate ❑Does Not [PR111 ;energy code compliance for the log :building envelope.Thermal M ❑Not Observable envelope represented on i ❑Not Applicable ; t x construction documents. 103.1, ;Construction drawings and = ❑Complies :Requirement will be met. 103.2, documentation demonstrate �ODoes Not 403.7 :energy code compliance for [PR311 ;lighting and mechanical systems z ti y❑Not Observable :Systems serving multiple ❑Not Applicable ;dwelling units must demonstrate #g compliance with the IECC 'b !Commercial Provisions. 302 1 3 Heating and cooling equipment is: Heating: Heating: ❑Complies ;Requirement will be met. 403:7 !sized per ACCA Manual S based Btu/hr Btu/hr ;❑Does Not [PR2P . •� on loads calculated per ACCA ! Cooling ! Cooling Manual J or other methods Btu/hr Btu/hr !❑Not Observable , approved by the code official. !❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 3 of 9 . . 402.1.1 :Conditioned basement wall R- R- ;.Elcomplies I See the Envelope Assemblies [F04]1 :insulation R-value.Where interior; :E]Does Not table for values. :insulation is used,verification !may need to occur during :E]Not Observable Insulation Inspection.Not :E]Not Applicable :required in warm-humid locations :in Climate Zone 3. ElComplies :Requirement will be met. 303.2 ;,Conditioned basement wall [F05]1 :insulation installed per El Does Not !manufacturer's instructions. :Location on plans/spec: A- �,x]Not Applicable 402.2.9 Conditioned basement wall ft ft ElComplies; ;See the Envelope Assemblies [F0611 :Insulation depth of burial or :E]Does Not table for values. ;clistance from top of wall. :E]Not Observable :E]Not Applicable to protect exposed exterior :not applicable. JODoes Not insulation and extends a -'E]Not Observable minimum of 6 in. below grade. �Snow-and ice-melting system Requirement will be met. Does Not )controls installed. 4,k1EINot Observable otApplicable AdditimnaUCommemts/Asomptioms: I I I High Impact(Tier 1) Medium Impact(Tier 2) 3-]Low Impact(Tier 3) Project Title: FE|N RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 4of 9 Sectionplans Ver�f�ed Field Verified f °# t Framing!Rough In Inspection Ualue 5x s Compi�es? Comments/Assumptions ..> H 402.1.1, ;Door U-factor. ; U- ; U- ;❑Complies ;See the Envelope Assemblies 402.3.4 i❑Does Not ;table for values. [FR1]1 1 ;❑Not Observable ;❑Not Applicable 402.1.1, :Glazing U-factor(area-weighted U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, average). ❑Does Not I table for values. 402.3.3, 402.5 UNot Observable [FR2]1 ; ;❑Not Applicable SI ; t 303.1.3 ;U-factors of fenestration products r 4❑Complies ;Requirement will be met. [FR4]1 :are determined in accordance 3 ❑Does Not with the NFRC test procedure or :taken from the default table. f �_ ❑Not Observable ; ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier e ❑Complies ;Requirement will be met. PSi [FR23]1 installed per manufacturer's t e ❑ instructions. - Does Not 0 '- ❑Not Observable ❑Not Applicable I Y I 402.4.3 ;Fenestration that is not site built , s f,% ❑Complies ;Requirement will be met. [FR20]1 :is listed and labeled as meeting ` ❑Does Not 0 ;AAMA/WDMA/CSA 101/I.S.2/A440 j for has infiltration rates per NFRC3❑Not Observable 400 that do not exceed code " ❑Not Applicable 40245 IC-rated recessed lighting fixtures 4 ❑Complies ;Requirement will be met. [FR16] sealed at housing/interior finish �• ❑Does Not ;and labeled to indicate<_2.0 cfm leakage at 75 Pa. �J❑Not Observable ; ' j _T =�❑Not Applicable ; 403.3.1 :Supply and return ducts in attics JOcomplies :Requirement will be met. [FR12]1 :insulated >= R-8 where duct is L ❑Does Not >=3 inches in diameter and >_ a I R-6 where< 3 inches.Supply and ❑Not Observable ; return ducts in other portions of ❑Not Applicable ; ;the building insulated >= R-6 for diameter>= 3 inches and R-4.2 _A ; !for< 3 inches in diameter. 403.3.2 ;Ducts, air handlers and filter ❑Complies ;Requirement will be met. [FR13]1 :boxes are sealed with _ ❑Does Not ;joints/seams compliant with CJ :International Mechanical Code or r ❑Not Observable :International Residential Code, as ❑Not Applicable ; 'applicable. ; 4033,5. Building cavities are not used as ;, y ❑Complies ;Requirement will be met. [FR15]3 ,' ducts or plenums. ti; ❑Does Not h �❑Not Observable ' 3 I j❑Not Applicable 4034 ;_; HVAC piping conveying fluids R- ; R- ;❑Complies ;Requirement will be met. [FRI7]z above 105 °F or chilled fluids ;❑Does Not " `I .:]below 55°F are insulated to zR- .� _ 3 i :[]Not Observable ; ;❑Not Applicable 403.4.1 ;Protection of insulation on HVAC ❑Complies ;Requirement will be met. [FR24]1 piping. ❑Does Not �[]Not Observable ; ❑Not Applicable 403 5:3 Hot water pipes are insulated to R- v R- ;❑Complies ;Requirement will be met. [FR18]z ?R-3. j ;❑Does Not ;❑Not Observable ;❑Not Applicable 1 High Impact(Tier 1) 2'; Medium Impact(Tier 2) 'S Low Impact(Tier 3) Project Title: FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 5 of 9 Section plans Ve rifietl Fleltl,Ver�fied Framing/Rough in Inspection _ Comphes� Comments/Assumptions &Req !D Value Value k 403i6 ,Automatic or gravity dampers are s ' ❑Complies ;Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. r ,'❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2'=Medium Impact(Tier 2) 3' Low Impact(Tier 3) Project Title: FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 6 of 9 se ction f x Plans Verifietl xFteld Vertfted nsulation lnspec#ton sx Cotnpites� Comments/Assumptions &nRe ID �� F r l/alue Value , , r 303 I ;All installed insulation is labeled Complies ;Requirement will be meta [IN13]2 _or the installed R-values El Not k Iprovided. QNot Observable y All Applicable 402.1.1, ;Wall insulation R-value. If this is a: R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, :mass wall with at least 1/z of the ❑ Wood ;❑ Wood ;❑Does Not :table for values. 402.2.E ;wall insulation on the wall ❑ Mass ❑ Mass :❑Not Observable [IN3]i exterior,the exterior insulation I ; j requirement applies(FR10). ;❑ Steel i❑ Steel ;❑Not Applicable ; 303.2 ;Wall insulation is installed per :❑Complies ;Requirement will be met. [IN4]1 manufacturer's instructions. []Does Not r []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3_Low Impact(Tier 3) Project Title: FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 7 of 9 Section plans Verified ` `FieldtUer�fted `# Final Inspection Provisions CompUes2 Comments/Assumptions. tie tD ,; Y '� a. Value Value , , . 402.2.4 ;Attic access hatch and door ; R- R- QComplies ;Requirement will be met. [FI3]1 insulation >_R-value of the ❑Does Not ;adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ; ACH 50 = ; ACH 50= ;❑Complies !Requirement will be met. [FI17]1 :ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 ;Ducts are pressure tested to ; cfm/100 cfm/100 ;❑Complies ;Requirement will be met. [FI27]1 ;determine air leakage with ft2 ;❑Does Not ;either: Rough-in test:Total :leakage measured with a ;❑Not Observable ; pressure differential of 0.1 inch I ;❑Not Applicable w.g. across the system including ;the manufacturer's air handler enclosure if installed at time of ;test.Postconstruction test:Total leakage measured with a ; pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.4 :Duct tightness test result of<=4 ; cfm/100 ; cfm/100 ;❑Complies !Requirement will be met. [FI4]1 :cfm/100 ft2 across the system or ft2 ft2 ;❑Does Not <=3 cfm/100 ft2 without air ; handler @ 25 Pa. For rough-in :❑Not Observable :tests,verification may need to ; ;❑Not Applicable ;occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated ,]❑Complies ;Requirement will be met. [FI24]1 :by manufacturer at<=2%of ❑Does Not design air flow. ,k ❑Not Observable ; ❑Not Applicable 4Q31 1 Programmable thermostats , a { ❑Complies Requirement will be met. [FI9]2 pN- installed for control of primary ,❑Does Not ; heating and cooling systems and ] ; initially set by manufacturer to }❑Not Observable , code specifications. 71 ❑Not Applicable 4031 2 Heat pump thermostat installed ❑Complies ;Requirement will be met. [FAO]z -'on heat pumps. ¢ ;" ❑Does Not ❑Not Observable ❑Not Applicable 403 5 1 � Circulating service hot water 2 3❑Complies ;Requirement will be met. (FI11]2 ksystems have automatic or ❑Does Not accessible manual controls. ;,' ry ❑Not Observable ; ❑Not Applicable .463.6.1 ' ]All mechanical ventilation system ❑Complies ;Requirement will be met. (FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy 3 fi i ❑Not Observable and airflow limits per Table n ❑Not Applicable ..:,R403.6.1. 4012 Hot water boilers supplying heat .❑Complies ;Requirement will be met. [FI26]2 —I through one-or two-pipe heating ]Does Not fisystems have outdoor setback ' j control to lower boiler water N a - �;]❑Not Observable (temperature based on outdoor ❑Not Applicable ; temperature. w - 11 High Impact(Tier 1) 2'°', Medium Impact(Tier 2) '31 Low Impact(Tier 3) Project Title: FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 8 of 9 a � + + Plans Nervfied , tF�eld Ver�f�ed Final Inspection Provisions; h � ,k � � <Complies�� Comments/Assumptions =. &,Re, iD, Valuek, fi Value t r 7 403 5 1 1 }Heated water circulation systems qElComplies !Requirement will be met. [FI28)z have a circulation pump.The ❑Does Not system return pipe is a dedicated j return pipe or a cold water supply ❑Not Observable ; pipe. Gravity and thermos- ❑Not Applicable ; isyphon circulation systems are jr t d 6 not present. Controls for ; )circulating hot water system �_ B { € pumps start the pump with signal for hot water demand within the } h a occupancy. Controls automatically turn off the pump a s r 'when water is in circulation loop ; is at set-point temperature and ,� r j no demand for hot water exists. 403 5 1 2 Electric heat trace systems i10Complies ;Requirement will be met. [FI29]z comply with IEEE 515.1 or UL )❑Does Not 515. Controls automatically a ❑Not Observable adjust the energy input to the "Y ti k heat tracing to maintain the "F� ❑Not Applicable ; desired water temperature in the x , I 403'5 2 ;Demand recirculation water _ ❑Complies ;Requirement will be met. [FI30]z systems have controls that `'❑Does Not manage operation of the pump r and limit the temperature of the 7` � st . ❑Not Observable , water entering the cold water ❑Not Applicable ; piping to<= 1049F. ; 403:5 4 Drain water heat recovery units ❑Complies ;Requirement will be met. [17131=]2 tested in accordance with CSA 1355.1. Potable water-side Y' ❑Does Not 4 �iQRI loss of drain water heat 3 ?❑Not Observable I f recovery units<3 psi for = rq< fi k n❑Not Applicable individual units connected to one A I F or two showers. Potable water- �` side pressure loss of drain water heat recovery units<2 psi for lindividual units connected to three or more showers. s3 404.1 ;90%or more of permanent ; '❑Complies ;,Requirement will be met. [FI611 :fixtures have high efficacy lamps ; ❑Does Not -'[]Not Observable ' R ,. rryr ❑Not Applicable 404 1�1 Fuel gas lighting systems have r , ❑Complies :Requirement will be met. [FI23} no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.1 i Compliance certificate posted. ❑Complies :Requirement will be met. [FI7 . ' ❑Does Not ❑Not Observable ; �'. ❑Not Applicable 30 3:3 Manufacturer manuals for t ' ❑Complies ;Requirement will be met. ,r ;[F118]3 , mechanical and water heating a 4❑Does Not systems have been provided. ' ¥ []Not Observable 1 ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2.` Medium Impact(Tier 2) [q3,,'.J Low Impact(Tier 3) Project Title: FEIN RESIDENCE MAINTAIN EXISTING FINISHED BASEMENT Report date: 02/22/24 Data filename: Page 9 of 9 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 0.00 Below-Grade Wall 20.00 Floor 0.00 Ceiling / Roof 0.00 Ductwork (unconditioned spaces): Glass & D. . Window 0.28 0.26 Door 0.28 CoolingHeating & Heating System: Cooling System: Water Heater: Name: Date: Comments Rood r1iEN D Er,E I 5-7--4" 24'-4" _.M 3-a i' I J K-N6 fee-- 14-8 7'-5 I/2 1 — — — — — — — — — I �` L1G3C�Gil�4CEC�4 [fig C1o�oLao 4-6 „ — _ — — — — — — --- - -� R25 19 INSUL �C�C�LalDal�l�`I �IRg0U19 r I I I A L - - J L - - J I HR FIRE EX15TING MI 0 PINRAL WOOL GIRDER I I I 1 m I I ` c, I I n m Q — — — — — — — — — — — — - L- - - L ak ISTFLOOR MQL°o EL. 0'-0" EX. FJ TO REMAIN - VENT TO u OUT5IDE i I Lm GONGPLAT AND 5TEP5100 5F OF 5/8 I PER NYSBG R311 GYP BD PAINTED TYPE X GYP BO. ABOVE EX. 10 GONG — ; ' f - - - - - - - -I � MECH. EQUIP. FOUNDATION WALL i TYP. _ — — _ - - - - - - _ I J O i 36' HAD IL 311151 DRYWELL 15 T EA 5 I I 2x4 STUDS I6 O.G. I S I NSUL BATT - ° t I I I I I I I m ` ` �` m a Hyl — _ 10 MIL VAPOR BARRIER FAI EX. REG. ROOM I R5 RIGID l N " HR SELF CLOSING — — — — — — — — — — — — — — — — — — —— — — — — — — — I O I DOOR I I b I nn � l -1:15x11.875 LVL GDR -� I EXISTING A I GLA55 (� '� in DOOR AN (ENGINEERED DESIGN) l I I FINSHED 02-22-24 ISSUED FOR A-2 I I I EXISTING 8" GONG BASEMENT OWNERS REVIEW PANEL 4-2 3-I I -l0 5-� I I FOUNDATION AND BEAM F- I I f— � I FOOTING TYP. 05-23-24 ISSUED FOR — � — � I I POCKET I I — I I — I I I 0 OWNER5 REVIEW ( T I I I I 1 m N I I u- m I t o WINE I IL — J L - - J L - - J I cv CELLAR A I I EX. 4" GONG. SLAB ON m = I I cn 17'-4" I A-2 I GRADE 4'� Ill I E) (3) x FL. F (E (5)- O IFL H ILL 5D UNDER BD I I I - O Q STAIR I EX. UNEXAGATED I do BASEMENT EL. -T-6 1/2" o N -NY5BG � IT l I I UTI . G .X ( 2" x 10" i� 3_ ry I P STAIR PER Iu- NY5BG R311 m o I I I I I _ + + _ I �I / BATHROOM �s sa 68 O 14'-q" w 5'-O" 3 O I I I I ® I + I I OI CO h 8 cn I SCALE: 1/2" = 1'-0" �D rJ 6 I I PULL 1 �+ I BOX � EX, GL., I EP ACCESS I I DROP FOUNDATION BELOW SLAB DROP FOUNDATION BELOW SLAB P15CONNEE T � �1 - - - - PANEL - - J L - - - - - - - - - - - - - - - DOOR OPENING ® DOOR OPENING � - - � r- - - - - � - - -1 E) (2)-2xi0 FLUSH - - - - - - - - - - - - - - J I METER — I VENT TO — — E) (2 x I0 FLU OUT51 DE — — - - —� — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — Ex. R z F - - A-2 l l N - - - - - J DEGK(ABOVE) - - - - - - - - - - - - 4" V. THRU ROOF 2'-q" F f f F- l — I —� I (2)-2x10 GDR l —� I — i —� I — I I — �J I EY- 1 1 I I I I I I I I ATTIC L - - J L - - J L - - J L - - J L- - - I L - - J G (E) 28x36 CASEMENT (— —— — — — — — — -T EGRESS WINDOW VENT I 4" 501L 1 P.G. FTC. 1 - -- - - - - - - -� BASEMENT NOTES: BATHROOM ((� BA5EMENT ARE NOT TO BE USED W -T 2" 7'-0" 2"4 FOR SLEEPING OR COOKING. N BASEMENT CAN NOT BE USED �j A5 A 5EPARATE LIVING UNIT. �t LLB Z 7'-0" 8'-0" 8'-0° 7'-0° 7'-0" BASEMENT USE FOR APPROVED �T� L — 1 1/2" 1 1/2"I U5E ONLY I I I I/2"I I I/2„I I I/2I WASHER I� x W �- LAV. LAV. I i ~ < 7- Z z 5HOWER W.G. I W.G. TUB TUB C� < v- W SECOND FLOOR P4 < Lu Lo SCALE: I/4 - I -O I 4" SOILG.O. Zi m ~ < G.O. �(��) < 411 411 411 4" POWDER z v ROOM KITCHEN NOTE: GENERAL NOTES: SMOKE ALARM TO CONFORM WITH R514 OF THE 2020 IRG. CARBON MONOXIDE I I I/2" uj X DETEGTORS TO OF THE 2020 IRG AND SHALL COMPLY WITH SECTION G15 OF THE 2020 1� FLOOR PLANS SHOWING E BUILT CONDITIONS EA COMPLETED TO � NOTE: i i� THE BEST OF OUR KNOWLEDGE AS PER FIELD MEASUREMENTS. I L�, • 2„I SINK N WINDOWS TO CONFORM WITH R310.2 OF THE 2020 IRG WHERE APPLICABLE THESE PLANS WERE DRAWN TO REPRESENT EXISTING CONDITIONS. o I F.A.I. ' - — — — — - EX. 8" POURED CONCRETE COMPONENTS SHOWN WERE BASED ON A VISUAL NON DESTRUCTIVE I P15H I FOUNDATION WALL TO "CLOSED WALL" INSPECTION W C - — — — — - REMAIN I SHE O d JEFF A ZAHN A.I.A. ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY FIRST FLOOR a v — — — — - NEW 8" POURED CONCRETE HIDDEN DEFECTS OR FAULTY CONSTRUCTIONS PRACTICES WHICH ARE �Jl FOUNDATION WALL TO NOT DIRECTLY V151BLE G.O. G.O. RESHG�GK GOi�fPLi?�NGE — — — — — — REMAIN NET BAR 4 SANITARY LINE JEFF A ZAHN A.I.A. ARCHITECT AND CONSULTANTS HAS NOT BEEN --- - TO EXISTING pG`:��eJC� CC�`l�#0 24-00c{ EX. 2"x6" OR 2"x4" WD RETAINED FOR THE SUPERVISION OF THIS PROJECT OR TO FILE ANY BATHROOM APPROVED INSULATION VALUES 514OWN ON SECTION ARE USED FRAMED WALLS @ 16" O.G. w/ OTHER APPLICATION RELATED OR REQUIRED TO THI5 PROJECT. 1--- - SEPTIC SYSTEM FOR RESGHEGK COMPLIANCE ALL VALUES MEET 1/2" G.W.B. EA. 51DE TO XHGI MINIMUM REQUIREMENTS REMAIN IT 15 THE RESPONSIBILITY OF THE OWNER TO FILE FOR AND OBTAIN I I 1 CAL°- DD GS'OKE-13 PROJEGT5 24-00q All REQUIRED APPROVALS AND PERMITS FROM ANY AND ALL I I/2 I I HOUSE TRAP ANDERSEN 400 SERIE=S WINDOWS TO CONFORM WITH NEW 2"x4" WD FRAMED GOVERNING AGENCIES HAVIN5 JURISDICTION OVER THIS PROJECT. I I I/2" R510.2 OF THE 2020 IRG WHERE APPLICABLE. WALLS © 16" O.G. w/ 1/2" SINK LAY I ` E BACK U-FAGTOR AND SHGG J5ED PER MANUFACTURES G.W.B. EA. 51DE JEFF A ZAHN A.I.A. ARCHITECT A55UME5 NO RE5PON516I,LITY FOR I FLOW VALUES. 050 SMOKE DETECTOR PRE-EXISTING VIOLATIONS, CODE/ZONING DEFICIENCIES AND I OR PREVENTER NON GONFORMING USAGE'S SHOWER ICE BARRIER TO BE INSTALLED MIN 24" INSIDE THE BASEMENT EXTERIOR WALL LINE OF THE BUILDING GO CARBON MONOXIDE JEFF A ZAHN A.I.A. ARCHITECT A55UME5 NO RESPONSIBILITY FOR DETECTOR DELAYS IN APPROVALS BY THE BUILD. DEPT. OR OTHER AUTHORITIES , ut INVOLVED. EXHAUST FAN MIN 75 GFM �— J ALL BUILDING PERMITS REQUIRE AN INSPECTION BY AREA 4" SANITARY LINE 4" INSPECTOR. EJECTOR PIT AN ELECTRICAL CERTIFICATE MAY BE REQUIRED. HOMEOWNER 15 RESPONSIBLE TO PROVIDE: ACCORDINGLY. " .O '~ SCALE: NTS i •S^ 93MEE7;4 M.—D o load U E MAINTAIN d��� Qo �Qaa9 a°aoQo 66 LQI�C�G110�'�C�4 rEl - RESIDEN 65, EXISTINGLU �fl� G30G1[n�OO C3�GQM[�[�MC� G3�MCC�G3G{]C�LaDg [n��'I ��g0� FIN COMPLY WITH ALL CODES Or a f EW YORK STATE&TOWN CODES -3 A As REQJ� ED ANQ coNDrr�oNs Q.- �CLado tommnaznrusm 29 5 A -AN. LEY R .D 85 JLK NY XL 1952 �P APPROVED AS NOTED 0�� 1�0 d ,��0 MASONRY PATIO ff�11 DAML± B.P.# SO 4 02-22-24 ISSUED FOR LUAINGGRAIL LLPPLUM�BINgG WASTE&WATER LINES NEED FEE m' OWNERS REVIEW w A IN-6ROUND SWIMMING POOL TESTING BEFORE COVERING 631-76 1802 BUILDING TO 4PM F DEPARTMENT H ,;631-765-1802 8AM TO 4PM FOR THE z ry FOLLOWING INSPECTIONS. _ FOUNDATION-TWO REQUIRED u FOR POURED CONCRETE Additional ROUGH-FRAMfNG&PLUMBING MASONRY PATIO MAINTAIN EXISTING Certification FINAL INSULATION MUST FINISHED BASEMENT May Be Required. Iowa SF BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MIEET THE REQUIREMENTS OF THE CODES OF NEW QQ YORK STATE. NOT RESPONSIBLE FOR �'T \ CONCRETE STEPS DESIGN OR CONSTRUCTION (ERRORS FFNGE GATE 2 STORY FRAME TO CELLAR H005E d GARAGE w ELECTRICAL PORCH _ \ � � _ u � INSPECTIOE! REQUIRED Gq7 N $'M i \ P�NGE 3 IO N \ \ kr e ?3700 z to N 73° IS'40" N 60.0' STANLI�r �o 'AT ) Z n �s) w — INFORMATION PROVIDED BY OTHERS FOR REFERENCE ONLY. 5EE 516NED AND SEALED SURVEY W x � � �- LU LU EXI5TING PERGENTAGE LOT GOVERAGE GFA < LU ~ E- EX. FIRST FLOOR 1215 SF FIRST FLOOR 1,767 5F Z EX. GARAGE 552 SF 5EGOND FLOOR 1201 5F F� _ EX. PORCH 241 51' LOT AREA 30,Q31 5F W N EX. GONG STOOPS 34 5F TOTAL GFA C1.6% TOTAL ADDITION 4 ALTERATION 2042 5F TOTAL LOT AREA 30,a31 5F PERCENTAGE LOT GOVERAGE 6.6% r' O � O N CS I �1 X � m DWG. INITIAL LATEST ISSUANGE NO. DRAWING TITLE ISSUANGE REVISION NO. DATE a T-I TITLE SHEET 02-22-24 A-1 5GHEDULES, NOTES & DETAILS 02-22-24 24-OOCI A-2 EXISTING BASEMENT PLAN 02-22-24 A-3 EXISTING FIRST FLOOR PLAN 02-22-24 @LaDD M I MI] PROJEGT5 24-00q A-4 EXISTING SECOND FLOOR 02-22-24 �' DG�LaM9�I�lC�#o 0aigi4 ma I of 5 TABLE 5.1 1=ASTENER SCHEDULE FOR STUGTURAL MEMBERS JOINT DESCRIPTION NUMBER AND TYPE OF NAIL 5PAGING F 5TE ER SIMPSON L5TA 30-00A. ROOF FRAMING 2" x 8" RR ® 16" O.G. RIDOE STRAPS AT EA. Rafter to ToI2 Plate Toe-nailed 3-Sd per rafter I. ALL FRAMING LUMBER TO BE GRADE STAMPED DOUOLAS FIR-LARCH RAFTER. Getiln Joist to To Plate Toe-nailed 3-8d12er joist STRUCTURAL GRADE NO. 2 OR BETTER. TYP. ROOFING Geilin Joist to Parallel Rafter Face-nailed 4-I6d each la 2. ALL EXTERIOR FRAMING TO BE STRUCTURAL GRADE GGA TREATED LUMBER. OR 3. ALL 5HEATHING TO BE AP.A. RATED, EXPOSURE I, 1/2" MIN. THICKNESS. Geilin Joist La s over Partitions Face-Walled 4-I6 � d each la I MIN. AIR SPACE Gollor Tie to Rafter Face-nalled 4-Sd per tie PERIMETER PANELS AT EDGE OF ROOF 4 WALL CORNERS TO BE NAILED ® 4" O.G. 2"x4" GOLLAR TIES AT Blockin to Rafter Toe-nalled 2-bd ALO each end ABOVE INSUL. NG EDGES 4 6" D.G. IN FIELD W/ SOLID BLKG. UNDER ALL SEAMS. 16" O.G. �" DOWN Rlm Board to Rafter End-nalled 2-I6d leach end 4. USE SOLID BLOCKING OR X- BRACING BETWEEN ALL JOISTS @ &'-0" MAX. SPACING. BETWEEN RIDGE AND WALL FRAMING 5. PROVIDE DOUBLE FRAMING UNDER ALL POSTS 4 PARALLEL PARTITIONS. CEILING JOISTS. M. E NK, Q°H°Q° To Plate to To Plate Face-nailed 2-I6d er foot 6. ALL FLUSH WD. CONNECTIONS TO BE FASTENED W/ RATED GALV. METAL To Plate at Intersections To<:-nailed 4-I6d olnts - each side CONNECTORS BY SIMPSON (OR EQUAL). Stud to Stud Face-nalled I6d 24" o.c. Header to Header Face-nalled 2-I6d I6 o.c. alongedges + + + + ��� QOLa[r OO C3C LaMCG`JMC Top or Bottom Plate to Stud i=nd-nalled �2-I6d per 2x4 stud L A Z I �I �)6 0 7 5 LAC BOLT NAILER W/ (2) er 2x6 stud I �: I � 3/8"d� x 4 I/2" BOLTS @ 32" O.G. 3-I6d �������Q�9 �� gm 4-I6d per 2x5 stud Bottom Plate to Floor Joist,Band olst,End olst or Bloc in Face-nailed) l2er foot WINOOW5/5L.GL.DOOR5 A5 MANUF.BY MARVIN,INTEGRITY W/IN5UL.6LA55,IMPAGT -- n TYP. EXT. TEGO EA. R.R. TO 2"x8" NAILER FLOOR FRAMING RE515TANT 4 DE516N PRE55l1RE RATED A5 REOV BY CODE OR USE: 5TRUGTURAL PANELS FOR WALL (2"x4" Joist to 5111 To Plate or &Irder Toe-nalled 4-Sd er joist STORM PROTEGTION- PROVIDE PRECUT,PREDRILLED PLYWOOD,7/I6'THICK. INCLUDE ATTACHMENT IN ATTIC • f3rialcling to Joist Toe-nalled 2-&d each end f3lockinal to Joist (Toe-nalled) 2-bd each end HARDWARE: 2 I/2"N08 W.SCREWS® Ib"O.G.F/5PAN5 UP TO b FEET,AND® SPACES) --- l3lockincl to 5111 or ToJ2 Plate -foe-nailed) 5-ibd each block 12"O.G.F/5PAN5 BETWEEN b 4 S FEET. Le or 5tri to Beam Face-nalled 3-I6d each oist Jois on Ledger to Beam Toe-nailed 3-8d er olst BUILDER TO VERIFY 4 CONFORM TO ALL REOUIREMENT5.REVIEW OPTION5 WITH OWNER.' Band Joist to Joist End-nailed 3-Ibd per joist - 2-I6d per oist Band Joist to 5111 or To Plate: Toe nailed OPTION: PROV. IW"PICTURE-FRAME TRIM(ALUM.GLAD)TO ATTACH 5TRUGT. PANELS.PREDRILL HOLE5 ROOF SHEATHING f F/HARDWARE,PROV.PLA5TIG IN5ERT5 TO PROTECT FROM WEATHER,ETC.(VERIFY DETAILS) Structural Panels 8d 6" edge /6" field Diagonal Board Sheathin 9, 1"xb" or I"xB" 2-8d per su p port - MAINTAIN I" CLEAR I"xl0" or wider 3-8d per support r &✓ '�. '�rH: a CEILING SHEATHING I � RA F H I FOR VENTILATION. A T I C� sum Wallboard Sd coolers 7" edge, / 10" field - NOTCH RR F/ WALL SHEATHING SHEATHING structural Panels ad b" edge / 12" field EA. J Fiberboard Panels " AMERICAN FOREST AND PAPER A550GIATION (AF4PA) HOOD FRAME EA. JST. 2-CONNECTORS @ 1/16" 6d 3 ed e / 6 field CONNECTORS � I6" O.G. 25/32" Sd 3" edge / 6" Reid GON5TRUGTION MANUAL FOR ONE AND TWO- FAMILY DHELLIN65. (2001 (ONE EACH SIDE) �����o C sum Wallboard Sd coolers 7" ed e / 10" field EDITION) 2"x6" R-3o INSUL. G.J. 02-22-24 ISSUED FOR Hardboard 8d b" ed e / 12" field Particleboard Panels Sd b" edge / 12" field OWNERS REVIEW Placlonal Board Sheathincl GROUND 5NOW LOAD 20 P5F TYP. ROOF, TIES: I"x6" or I"x8° 2-Sd per support 1"xlo" or wider 3-Sd er su ort W1�5PffD°50UTtblD 130 MPH (3 SECOND GUST) 51MP50N "HT' I'-4" op FLOOR SHEATHING WIND EXPOSURE CATEGORY B ( SUBURBAN, SEMI-WOODED) CONNECTORS ® 16" O.G. U.N.O. X4� Structural Panels SEISMIC DESIGN GATEGORY C I" or less 8d 6" ed e / 12" field reater than I" lod 6" edge / 6" field WEATHERING AREA SEVERE Dia onal Board 5heathing ICE SHIELD YES I"xb" or I"x8" 2-&d per support 1'-0" x O or wider 3-8d per support FROST LINE DEPTH 3'-D" U.N.O. ROOF SHIN61-E5 TERMITE AREA MODERATE TO HEAVY Asphalt roof shin les Galy. stl., min.,II2 ga. shank w/ a min. 5/5" dia. head. fastener shall penetrate DECAY AREA SLIGHT TO MODERATE P g through the roofing materials and a min. of 3/4" into roof sheathing and shall WINTER DE510N TEMP 11 I roofing manufacturer and provide no less than 4 fasteners 12er strI12 ShinplO. 1 Nalling requirements are based on wall sheathing nalled 6" on center at the panel edge. If wall sheathing Is nalled 3" on center at the panel edge to obtain higher shear capacities,nailing requirements for structural members shall be doubled,or alternate connectors, such as shear plates shall be used to maintain the load path. �®� � ®� � • =Nalling requirements are based on wall sheathing nailed 6" on center at the panel edge. If wall sheathing Is nalled 3" on center at the panel edge to obtain higher shear capacities,nailing requirements for structural members shall be doubled,or alternate connectors,such as shear plates shall be used to maintain the load path. DOUBLE TOP PLATE R305 Glazing at hazardous locations shall have glazing protection in conformance with r3O&. In general, glazing In all doors and fixed side panels, Glazlngs less than 60" above surfaces of tubs showers, etc. Glazing within 24" arc of doors In closed position with sills less than 60" NOTE: ALL GONSTRUGTION WORK SHALL BE DONE IN AGCORDANGE WITH THE above f►oor. Glazings over q square feet and less than 15" above finished floor. Glazing near REGUIREMENT5 OF THE TOWN OF SOUTHOLD AND THE FOLLOWING: stairways/landings. See complete text of R308.4. Glazing for specifics on locations and HEADER exceptions. THIS APPLIGATION/ PROJEGT WILL CONFORM TO THE 2020 RESIDENTIAL R305.6 Skylights and sloped glazing shall comply with this section and have fully tempered b z GORE OF NEW YORk� STATE glazing. i FULL HEIGHT STUD R3oa Garage opening protection and separation required to be as noted and in conformance ENGINEERED STRUCTURAL GOMPONIENTS A5 PER ASGE -10 with R309. Garage floor surfaces shall be sloped to facilitate the movement of liquids to drain 1-4" x If3 OAUCE HEADER TO STUD: BY SIMPSON CODE COMPLIANCE_ toward the main vehicle entry doorway. JACK STUD STEEL GOLIED L5TA21 CONNECTOR W/ I6-IOD THESE PLANS HAVE 13EEN PREPARED UNDER THE 2020 RESIDENTIAL CODE OF NEW k STRAP NO. 650 FASTENERS YORK STATE. ALL DETAILS AND INFORMATION HEREIN IS CERTIFIED BY THE R310.1.1 All emergency escape and rescue openings shall have a minimum net clear opening of TYP. FLOOR LISTED DESIGN PROFESSIONAL AND IN GOMPLIANCE WITH THE FOLLOWING: 5.7 square feet. 24" minimum clear opening height, 20" minimum clear opening width, 44" max still JOIST BY 51MP50N height. UNDER JOIST(12" I. 2020 INTERNATIONAL RESIDENTIAL GODS FOR ONE AND TWO FAMILY HOUSES END LENGTH) 16" WINDOW SILL 2. 2020 NYS UNIFORM GODS SUPPLEMENT FINAL, INSTALLED STAIRWAYS, HANDRAILS, GUARDS SHALL BE INSTALLED IN FULL O.G. PLATE 3. 2020 IEGG I CONFORMANCE WITH THIER RESPECTIVE CODE SECTIONS. ARCHITECT IS NOT RESPONSIBLE 4. ENGINEERED 5TR.UGTURAL GOMPONENT5 PER A56E 7-10 FOR THESE INSTALLATIONS. BOX BEAM. STUD TO PLATE: 5. WOOD FRAME GONSTRUGTION MANUAL 200 EDITION FOR ONE AND TWO STORY MATCH FJ SIMPSON HDUS" UPLIFT FAMILY DWELLINOS R314 Stairways shall not be less than 36 inches In clear width at all points above the permitted handrail height and below the required headroom height. Handrails shall not project more than CONNECTOR W/ J" DIA.. THERE SHALL BE NO DEVIATION IN )NSTRUGTION PRAGTIGE FROM THE 4.5 inches on either sideof the stairway and the minimum clear width of the stairway at and below TYPICAL AT CORNERS, REGUIREMENT5 OF THESE DOGUMENTS. the handrail height, including treads and landings, shall not be less than 31.5 inches where a OF BUILDINO AND AT MATERIALS SHOWN AND SPECIFIED ON THESE PLANS HAVE BEEN CHOSEN BASED handrail is installed on one side and 2-1 inches where handrails are provided on both sides. The BOTTOM PLATE ENDS OF SHEARWALLS. maximum riser height shall be 5.25" and the minimum tread depth shall be cl" in conformance with ON PERFORMANCE DATA AND MANUFAGTURER5 RECOMMENDATIONS. AND R314.2. Minimum headroom 6'-8'. All stairs shall be. provided with illumination In accordance with E- SUBSTITUTIONS WILL 13EGOME THE BURDEN AND REASONABILITY OF THE -I e CONTRACTOR TO VALIDATE THE COMPLIANCE WITH CODES AND TESTING Section R303.4. Enclosed accessible space, under stairs shall have walls, under stair surface W PROGEDURE5, INGLUDING THE PRODUCTION OF ANSI TEST RESULTS , AAMA TEST and any soffits protected on the enclosed side with I/2-inch gypsum board. r , Z Uj N RESULTS, ETC. R315.1 Handrails having a minimum and maximum heights of 34 inches and 38 inches, respectively, �j �-- w measured vertically from the nosing of the treads shall be provided on at least one side of l _ Q ® stairways. All required handrails shall be continuous the full length of the stairs with two or more W VS) ' n risers from a point directly above the top riser of a flight to a point directly above the lowest ^ V riser of the flight. Ends shall be returned or shall terminate In newel posts or safety terminals. H i. All electric- work shall comply with the ,National Electrice Code. Electrician shall Handrolls adjacent to a wall shall have a spce of not less than 1.5 Inches (38mm) between the h-I W m -1 obtain fire underwriter=_ certificate for all electric work and shall submit to owner. wall and the handrail. The handgrip portion of handrails shall have a circular cross section of (� Z CD 7 s Provide all outlets and junction boxes required for all appliances, pumps, equipment, 1-1/4 Inche minimum to 2-5/8 Inches maximum. Edge radius of I/W. etc. Contractor shall review service requirements, all lighting, outlets, fixtures, phone - L - jacks, T.V. cable jacks, etc. with owner as required for the full installation and R316.1 Guards are to be a minimum of 36 inches (C114mm) in height. Open sides of stairs with a < Z satisfaction of owners requirements and ''code compliance and shall provide some. total rise of more than 30 Inches above the floor or grade below shall have guards (each side) Architect 15 not responsible for electrical designs for this project in any capacity. not less than 54 Inches in height measured vertically from the nosing of the treads. (second ~J Z 2. All plumbing work shall comply with the National Plumbing Code and all local codes. story guards are recommended to be higher.) F�--ii LU Contractor shall review with the owner the requirements for plumbing lnstallotions FH _ N Including but not limited to fixtures, trim, 6, ssories, etc. and re uirements for water TYP. FND. TIES: i-+y g q R3ITI Single and multiple-station smoke alarms shall be installed in each sleeping room, outside service and domestic hot water. Architect is not responsible for any plumbing systems of each separate sleeping area in the immediate vicinity of the bedroom, on each additional 51MP50N "HDU5" TYP. ANCHOR BOLT: in any capacity. Gontra(Aor shall provide'sanitary system In accordance with the story of the dwelling, Including basements. The alarm devices shall be interconnected in such a GONNEGTOR W/ (2) 5/8"DIA. 48" O.G. owners approved site plan and shall coordinate all inspections required for approval manner that the activation of one alarm will activate all of the alarms in the individual unit. The of same. And surveys indicating final tank locations shall be by owners surveyor. alarm shall be clearly audible in all bedrooms over backround noise levels with all intervening DIA. THRU BOLTS. COORDINATE PLACEMENT Contractor shall provide surveyor with information as required. (TYPICAL AT GORNERS W/HOLD DOWN BOLTS. VERIFY p y q, doors closed. All smoke alarms shall be listed and Installed in accordance with the provisions ls) 3. All H.V.A.G. work shall comply with Article 10 of the N.Y.S. Uniform Fire Prevention of this code and the household firewarning equipment provisions of NFPA72. OF BUILDING AND AT BOLT TYPE,EMBEDMENT,REBAIR t- and Building Code, and Energy Code. Contractor shall review all mechanical systems ENDS OF SHEARWALL ETC. BEFORE CONSTRUCTION 0S) i with owner for type of system to be provided (I.E. oil, gas, or electric, hot water or R31a.1.2 Wall and Gelling finishes not including trim, door, and window frames shall have a N air, etc.) Including air conditioning requirements. Architect Is not responsible for flame-spread classification of not greater than 200. Wa11 and Gelling finishes shall have a o Z b Z I heating or air conditioning systems in any capacity. smoke-developed index of not greater than 450. EXIST. FLOOR Y �] � °° 4. owner shall obtain can and all required permits prior to allowing contractors to R322. A vapor retarder shall be installed on the warm-in-winter side of insulation. EXIST. FLOOR o m y q, p p g p JOIST `� - Rq proceed with any of the work. RIOOLI Masonry chimneys shall be constructed, anchored, supported, and reinforced as required JOIST Do �l 5. All site work including sanitary system; ut►lities, easements. setbacks, elevations, 1n this chapter and the applicable provisions of Chapters 3, 4, and 6 with applicable clearances E drainage, retaining walls, etc. shall be In accordance with a site Ianpre-pared the to combustibles and firesto In I- x 18 CAUCE STEEL I- x 18 GAUGE STEEL & [� 9 9 p pp 9 V owners surveyor. The Architect Is not responsible for site designs of any type in any GOLIED STRAP WRAPPED GOLIED STRAP WRAPPED to capacity. Rb07.1 Attic access. An attic access opening shall be provided to attic areas that exceed 30 UNDER SILL AND OVER UNDER SILL AND OVER 6. All work shall be performed by licensed contractors whom are experienced with square feet and have a vertical height of 30 Inches or greater. The rough-framed openlnh shall EACH STUD W/ 12" MIN. EACH STUD W/ 12" MIN. e���11#° 24-OOG the type of work being performed. All contractors shall maintain liability insurance and not be less than 22 Inches by 30 Inches and shall be located in a hallway or other readily STUD BEARING. NO. G50 STUD BEARING. NO. G518 ° workers compensation Insurance in connection with all work being performed in accessible location. A 30-Inch minimum unobstructed headroom in the attic space shall be BY SIMPSON BY SIMPSON project. provided at some point above the access opening. See Section M1305.1.3 for access �. All materials, systems, equipment, fixtures, etc, shall be installed in strict requirements where mechanical equipment is located in attic. R-30 INSUL. 94H R-50 IN5UL. compliance with the manufacturers written specifications and installation instructions W/ VAPOR BARRIER UP W/ VAPOR BARRIER UP n @�° Tod�o PROJECTS 24-009 Including all clearances for service, etc. 'i R808.1 Combustible insulation shall be separated a minimum of 3 inches from recessed lighting • .d z • .; z 8. All contractors shall warrant their work in writing to the owner for a minimum fixtures, fan motors, and other heat-producing devices or separated in accordance with the FOUNDATION A period of two years. conditions stipulated In the fixtures listing. Recessed lighting Installed 1n the building thermal WALL FOUNDATION �. GRADE GRADE D e ° ci. The Architect shall not have control bar charge of and shall not be responsible envelope shall meet the requirements of Section N1101.3. WALL -- -- �QQ����#° for construction means, methods, techniques, sequences, or procedures, or for safety programs In connection with the work or for acts or omissions of the contractor, G I I /� PITCH FINAL GRADE L PITCH FINAL GRADE subcontractors or any person performing any of the work, or for the failure of any of �J I (�i �•®fit AWAY FROM WALLS TYP. ° AWAY FROM WALLS TYP. them to carry out the work In accordance with the intent of the contract documents in that said responsibllty Is the sole responsibility of the contractor. LIVE DEAD 10. All exterior doors, roofing shingles, trim, siding, etc.. shall be reviewed and 20 10 ROOF : 5Now LOAD: approved by owner. PER .12 PITCH II. All interior finishes Including but not limited to walls, flooring, tile, etc. shall be 40 10 DECKS / PORCHES reviewed with and approved by owner. 12. All miscellaneous interior Items Including but not limited to doors, trim, fireplaces. 40 ID ROOMS OTHER THAN 5LEEPING ROOMS closet shelving, kitchen cabinets, shelving. hardware, etc. shall be reviewed with and 30 10 SLEEPING ROOMS approved by owner. 15. Where existing walls, posts etc.. are removed it Is the responsibility of the 20 10 ATTICS WITH STORAGE contractor to provide temporary support, shoring, bracing, etc. as required. ATTICS WITHOUT STORAGE 10 10 �G�CC�I' ►Do °0 2 0f 5 24'-4" Oluip Lao Emmo L.n.L-Ao 4'-6" 1 �/— LaG3C�Cz]�4CC�4 r _ —— — —— — — �- - � R25 —— — — — — -� IN5UL 2�9 GOO LQMOO C3C Law[EHUE I I I A nowlmm )q air T T @)oT r- — — -1 I L _ _ J L __ J A-2 i I I HR FIRE EXISTING @01. 2T.@& 5TOPPIN6 GIRDER m ( I O I I m I I O I I MINERAL WOOL — � L_ - - -� L - --- - - - - - - - - -- - - - - -- - - - - -- - - I II 1ST FLOOR Q/� n o � EL. 0'-0 " EX. F-I TO REMAIN VENT TO I I 34'-0" a [7� ' OUTSIDE 1 rcy� ti �r Lm dJ I GONG PLAT AND 5TEP5 `" I jl I 100 5F OF 5/&" , -pr', O TYPE "X" GYP �r I PER NYSBG R311 I _ ABOVE L -- - - - - - - - �" GYP BD PAINTED BD. EX. —— — — — — — — — — — MEGH. EQUIP. FOUNDATION WALLF-1 T � TYP. - -- - - — ==- - - - =— t a I I- 11 D 36 I PYNELL 5 /p 11+ I I I I I m IS INSUL BATT 2x4 5TUD5 0 I6 O.G. FAI HW —— —— — — —— .�EX. REG. ROOM 10 MIL VAPOR BARRIER " HR SELF I R5 RIC ID GLO5ING - - - - - - - - - -- --- - -- -- DOOR r- - - -- -- - - - 1 I m I ❑ A_2 II Il II /A r(30-1.15x11.&15 LVL GDR U*' i i o EXISTING -, EGINEERED DSIGN) in DOOR AN D FOR EXISTING8GONG4'-2° 3-II° BASEMENT OWNERS REVIEWPANEL BEAM FOUNDATION AND POGKET F- FOOTING TYP. o Il I — I — Q m I I I = _ J ° WINE I L _J L- - - -J L - - -J I I I m m CELLAR I I-f'-4" I 2 i EX. 4" GONG. SLAB ON E) (3) x FL. I (E (3)-2 O IFL H I 5DUNOYP DER BD I I I GRADE I I EX. UNEXACATED _J L o �5TAI I BASEMENT N Go -NYSBG o I I I N EL. --7'-6 1/21011 3'-211 N I P 5TAIR PER 1 S ® 1 I I �-- - - - - - J II I � LL 31-2 NY5BG R311 � o N I cxv sa sa Q �o 14'-q° 5'-0" 3'-0' I I A L L 5 C 7 l O N BATHROOM +sa G I I � m � 6 I I 1 SCALE: 1/2" = 1'-0" I l_ — —411 10- b "+b �6 EX GL. 1 X G I ACCESS I I DROP FOUNDATION BELOW SLAB DROP FOUNDATION BELOW SLAB L - _-- _- - - - PANEL @ DOOR OPENING (9 DOOR OPENING III - I VENT TO E) (2)-2x10 FLUSH ) (2 -2x10 FLU OUTSIDE o - - -I I-- - - - - - J 1- - - 2 - - -� r - - - - - - - - - - - - - - -- — - - - -- -- - - - - - - _ N I I - -- - -- - -- - - - PECK(ABOVE) - -- - - - - -- - - - 4" V. THRU ROOF 2'-cl q'-2" 2'-q11 It 8_p 21-q" a_2 2_a ol 21-811 3'_411 i (2)-2x10 GDR I — I _ I I _ I _ I _ I ° I I —° I I El ATTIC J L _ _ J L — _ J L _ - J L _ - J L _ _ J O (E) 25x36 CASEMENT j � -- - - - - - - -1 EGRESS WINDOW P.G.FTC. 1 VENT 4" 501L E —— — — — — — A5EM N NOTES: BATHROOM B E T BASEMENT ARE NOT TO BE U5ED I-T _ — — W N 2" 7'-O" 2"--,,, FOR SLEEPING OR COOKING. �" r , BASEMENT GAN NOT BE USED � T I I `� � �J A5 A SEPARATE LIVING UNIT. I I _ �'-o" 8'-0" a'-o" 7'-0" 7'-0" BASEMENT USE FOR APPROVED ,, nnLu USE ONLY 11 1/2" I2, I I/2" I I/2" 2„I I I/2"I I I/2"I I V2" I W U 1, LAV. I LAV. WASHER F"--i x w Z 5HOWER W.G. I W.G. I B Iv- F-iOL CD z Z Lu OU NA7 ( ON FL-AN IOaa 5F W Z < � I F\J�(D SGi�LE: I/�F" I'-O°= SECOND FLOOR nJ < QLu �wJ 411501L 4.1 4 II 411 411 POWDER W z ` V ROOM KITCHEN Z u NOTE: I GENERAL NOTES: I , X SMOKE ALARM TO CONFORM WITH R314 OF THE 2020 IRG. CARBON MONOXIDE I 1 I/2" DETECTORS TO OF THE 2020 IRG AND SHALL COMPLY WITH 5EGTION qI5 OF THE 2020 FLOOR PLANS SHOWING A5 BUILT CONDITIONS AND COMPLETED TO Q � NOTE: THE BEST OF OUR KNOWLEDGE AS PER FIELD MEA5UREMEINT5. I L ' 211I SINK 00 WINDOWS TO GONFORM WITH R310.2 OF THE 2020 IRG WHERE APPLIGABLE I F.A.I. O THESE PLANS WERE DRAWN TO REPRESENT EXISTING CONDITIONS. - - ---- EX. 8" POURED CONCRETE COMPONENTS SHOWN WERE BASED ON A VISUAL NON DESTRUCTIVE I W G DISH a FOUNDATION WALL TO "CLOSED WALL" INSPECTION - -- - -- REMAIN SHE a \-$ JEFF A ZAHN A.I.A. ARCHITECT WILL NOT BE RESPONSIBLE ARE FOR ANY I FIRST FLOOR N DEFECTS OR FAULTY CONSTRUIONACTIGES WHIGH a - - - - - - HIDDEN CONSTRUCTIONS PR NEW 8 POURED GONGRETE I 0 ,:. " µ FOUNDATION WALL TO NOT DIRECTLY VISIBLE G.O.G.O. RESHGEGK GOMPLIANGE — — — — — — REMAIN WET BAR 4" SANITARY LINE JEFF A ZAHN A.I.A. ARCHITECT AND CONSULTANTS HAS NOT BEEN -- -_ -_ TO EXISTING pG30�JGC�4#o 24-ooq EX. 2 xb OR 2x4 HD RETAINED FOR THE SUPERVISION OF THI5 PROJECT OR TO FILE ANY BATHROOM APPROVED INSULATION VALUES SHOWN ON SECTION �RE USED FOR RESGHEGK COMPLIANCE ALL VALUES MEET FRAMED WALLS 0 lb" O.G. w/ OTHER APPLICATION RELATED OR REQUIRED TO THIS PROJECT. SEPTIC SYSTEM MINIMUM REQUIREMENTS 1/2" G.W.B. EA. 51DE TO REMAIN IT IS THE RESPONSIBILITY OF THE OWNER TO FILE FOR AND OBTAIN XHGI Q%P VOID PROJEGT5 24-OOq All REQUIRED APPROVALS AND PERMITS FROM ANY AND ALL HOUSE TRAP ANDER5EN 400 SERIES WINDOW5 TO GON ORM WITH NEW 2"x4" WD FRAMED I I/2" R310.2 OF THE 2020 IRG WHERE APPLICABLE. GOVERNING AGENCIES HAVING JURISDICTION OVER THIS PROJECT. LAV WALLS ® I6" O.G. w/ I/2" SINK I f BACK U-FACTOR AND SHGG USE-P PER MANUFACTURES G.W.B. EA. 51DE VALUES. JEFF A ZAHN A.I.A. ARCHITECT ASSUMES NO RESPONSIBILITY FOR W G FLOW I 05D SMOKE DETECTOR PRE-EXISTING VIOLATIONS, CODE/ZONING DEFIGIENGIE5 AND I OR I SHOWER I PREVENTER IGE BARRIER TO BE INSTALLED MIN 24" INSIDE THE NON GONFORMING USAGE'S EXTERIOR WALL LINE OF THE BUILDING BASEMENT GO CARBON MONOXIDE JEFF A ZAHN A.I.A. ARCHITECT A55UME5 NO RESPONSIBILITY FOR DETECTOR DELAYS IN APPROVALS BY THE BUILD. DEPT. OR OTHER AUTHORITIES INVOLVED. F EXHAUST FAN MIN -f5 GFM ALL BUILDING PERMITS REQUIRE AN INSPECTION BY AREA �- 4" SANITARY LINE 4" INSPECTOR. I � �1:��11 � �#� � EJECTOR PIT AN ELECTRICAL CERTIFICATE MAY BE REQUIRED. HOMEOWNER IS6 I v RESPONSIBLE TO PROVIDE ACCORDINGLY. SGP�LE: NT5 24'-4" 7'-5 1/2 17'-10 6'_6 dmpi� L1° Kim, &.U. 1, L1G3GCzl U10v - - - - - -� I I _i 3 I _ - - - - - - INSUL 2TOaoQaoa1EadEEaWE I I I I A RuMCGt3G[1LaoD9 mu TTg0T _ _ I HR FIRE EXISTING @oT. 2T.@ 44 L — _ J L _ _ J STOPPING GIRDER I f� I m I lO I I m I I O I I MINERAL WOOL r _ � L_ - - -I I- - -- -- - - -- - - - - - - - - - - - - - - - - - - - -i L_ - - -J L — � IST FLOOR EL. O'-O' EX. FJ TO REMAIN I I RED AR VENT TO I I 54'-0" OUTSIDE i i 100 SF OF 5/8" Q I GONG PLAT AND STEPS O TYPE "X" GYP �t I PER NY55G R311 GYP BD PAINTED rz -op I - L. - - - - - - - - - - F J I BO. ABOVE EX. 10 GONG MECH. EQUIP. FOUNDATION WALL I TYP. _ _ . - - - - - - - - - - - -- - 36 HAD IL II78] IS INSUL GATT ate: I o m m I DRYWELL 15 A s/� II(' I I I I I I I m 2X4 STUDS @ I6" O.G. R NEB FAI HH w EX. REG. ROOM 10 MIL VAPOR BARRIER I " HR 5ELF I RS RIGID - - - -- - - - - - - - - -- -- - - - - - - nnnn - -1 I DOOR NG i - - - - - - - I (30-1.-5x11.&75 LVL GDR - A I I =— GLA55 (ENGINEERED DESIGN) EXISTING A-2 ( DOOR AN 5-� I I I FINSHED 02-22-24 ISSUED FOR 8" PANEL 4'-2" 3'-II" -t'-lo" ' " I I I EXISTING FOUNDATION AND GONG BEAM BASEMENT OWNERS REVIEW POCKET I I r - r F_ I I I _ FOOTING TYP. 05-23-24 ISSUED FOR _ � I I I i I O OWNERS REVIEW Q O O I I I I p L _ J L _ _J L _ _ J I m , - J CELLAR I I I A I I EX. 4" GONG. SLAB ON = m I�-4 I p`-2 I I GRADE L I I(E) (3) x F FL. F (B (3)- O IFL H SD UNDER BD I I I - % i = 3 O — b STAIR I EX. UNEXAGATED I I BASEMENT // x GO oNY5E30 Uo m I I I EL. -7'-6 1/2" I I U�� x P 5TAIRPEP, I� N I I I L _ _ — _ _ J u_ - - J I o 3-2 NYSBG R311 w Z) I I I I X � �� � x I I � � q-2 �+ �+ o cv I I I 68 68 I I // BATHROOM �+ 14'-q" w 5'-O" 3'-O' I I i A L L 5 C 7 I O N SCALE: 1/2" = 1'-o" 1z P I PULL NEI X. G (A foy . Gn � I BOX �L I €P ACCESS I I DROP FOUNDATION BELOW SLAB DROP FOUNDATION BELOW SLAB DISGONN . @ DOOR OPENING _ - - @ DOOR OPENING PANEL - - J L - - - - - - - - - - - - - - - METE I - _ r - -- - - - - - - - - E) (2L,1 FLUSH E) (2 x I o FLU I VENT TO — _ A OUTSIDE - - _ _ _ _ _ I- - iv I X. RP I A-2 I I iv - - - - - DECK(ABOVE) - - - -- - -- - - - - 4" V. THRU ROOF G'-2" 2'_'1 8'_p" 2'_a" q'_2" 2'_q' 2_8 8'_4 I'_8" 8'_4„ 3_4 Ilk F_ -1 F_ -1 F_ _1 F_ -1 F_ -1 F_ -I I I i I (2)-2xlo GDR L _ _ J L _ _ J L _ _ J L _ _ J L - -J L _ - J O (E) 28x36 CASEMENT f— E6RE55 WINDOW I P.G. FTC. I VENT 4" 501E - - - - - - - - BASEMENT NOTES: BATHROOM - BASEMENT ARE NOT TO BE USED — w ` N 2flI" 71_0" 2 FOR SLEEPING OR COOKING. _ F 1 _ Lu BASEMENT CAN NOT BE USED (� I I "� `�/ Q U) Z A5 A SEPARATE LIVING UNIT. I I _ 8'-0" 8'-0" 7'-0" 7'-0" BASEMENT USE FOR APPROVED I 1.1_..I 1 - USE ONLY 11 1/2" I 1 1/2" 1 1/2" „) 1 1/2"I 1 1/2"I I I/2" I W — I () 2 LAV. I LAY. 211 WASHER F--� x < J Z 5HOWER W.G. I W.G. TUB I B I(�-•1 CD Z �Z Z LI 10Q9 5F W QI_ :D 7- SECOND FLOOR � � < Lu 4" 501 I-- U_ I- ks) G.O. I G.O. �J Z m T ~ 411 4"4° I 411 V Z ROOM KITCHEN NOTE: GENERAL NOTE5: I "- SMOKE ALARM TO CONFORM WITH P-314 OF THE 2020 IRG. CARBON MONOXIDE DETECTORS TO OF THE 2020 IRG AND SHALL GOMPLI' WITH SECTION q15 OF THE 2020 FLOOR PLANS SHOWING AS BUILT CONDITIONS AND COMPLETED TO NOTE: 1 THE BEST OF OUR KNOWLEDGE AS PER FIELD MEA5UREMENT5. I ��(�° SINK °° N WINDOWS To CONFORM WITH R310.2 OF THE 2020 IRG WHERE APPLICABLE: 2 O THESE PLANS WERE DRAWN TO REPRESENT EXl5TING CONDITIONS. I o 11 F.A.I. ' - - - - -- EX. 8" POURED CONCRETECOMPONENTS SHOWN WERE BA51ED ON A VISUAL NON DE5TRXTIVE W G• P15H FOUNDATION WALL TO CLOSED WALL INSPECTION 5HE O - - - - - - - REMAIN JEFF A ZAHN A.I.A. ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY I FIRST FLOOR a - - - - -- NEW 8" POURED CONCRETE HIDDEN DEFECTS OR FAULTY CONSTRUCTIONS PRACTICES WHICH ARE N ^':.';•: ': :c'.� FOUNDATION WALL TO NOT DIRECTLY VISIBLE G.O.G.O. - - - - REMAIN WET BAR 4" SANITARY LINE RESHGEGK c".OMPLI�NG JEFF A ZAHN A.I.A. ARCHITECT AND CONSULTANTS HAS NOT BEEN I'- TO EXISTING GpGOd[ 04#° 24-OOa INSULATION VALUES SHOWN ON SEC ION ARE USED EX. 2"x6" OR 2"x4" WD RETAINED FOR THE 5UPERVIVON OF THI5 PROJECT OR TO FILE ANY I BATHROOM APPROVED ° FOR INSULATION RE5C \GK GOMPLIAN O ALL VALUES MEET FRAMED WALLS ® 16" O.G. w/ OTHER APPLICATION RELATED OR REQUIRED TO THI5 PROJECT. F— T_ - 5EPTIc SYSTEM MINIMUM REQUIREMENTS I/2" G.W.B. EA. SIDE TO REMAIN IT 15 THE RESPONSIBILITY OF THE OWNER TO FILE FOR AND OBTAIN I 1 1/2"( I XHGI (G M°- FD [YO[LE1; PROJEGT5 24-OOq All REQUIRED APPROVALS AND PERMITS FROM ANY AND ALL HOUSE TRAP ANDERSEN 400 SERIES WINDOWS T GOVERNING CONFORM WITH NEW 2"x4" WD FRAMED AGENCIES HAVING JURISDICTION OVER THIS PROJECT. I I I/2" R310.2 OF THE 2020 IRG WHERE APPLIGABLE. WALL5 ® 16" O.G. w/ 1/2" SINK LAV U-FACTOR AND 5H66 USED PER MANUFACTURES I f E BACK G.W.B. EA. SIDE JEFF A ZAHN A.I.A. ARCHITECT ASSUMES NO RESPONSIBILITY FOR W.G. FLOW VALUES. DQmMJ�Ii 0 M#o �SD SMOKE DETECTOR PRE-EXISTING VIOLATIONS, CODE/ZONING DEFICIENCIES AND I OR SHOWER I PREVENTER ICE BARRIER TO BE INSTALLED MIN 24" IN51DE THE NON CONFORMING USAGE'S - EXTERIOR WALL LINE OF THE BUILDING BASEMENT GO CARBON MONOXIDE JEFF A ZAHN A.I.A. ARCHITECT ASSUMES NO RESPONSIBILITY FOR DETECTOR DELAYS IN APPROVALS BY THE BUILD. DEPT. OR OTHER AUTHORITIES INVOLVED. EXHAUST FAN MIN 15 GFM ALL BUILDING PERMITS REQUIRE AN INSPECTION BY AREA �- " " '✓ ; 4.--6'• v 4 SANITARY LINE 4 INSPECTOR. I � �IA � �� EJECTOR PIT �I AY 2 g 2024 AN ELEGTRIGAL CERTIFICATE MAY BE REQUIRED. HOMEOWNER IS RESPONSIBLE TO PROVIDE ACCORDINGLY. SCALE: NTS d � Qo �QG;Jflv]9 QoDoQo G1G3C�G��4CEC�4 ��� aoceaaoa� ad�a�� G30MC�G�G`�GLaD9 `�1� ��g0� 6�3�0 7�51 o0g4'� o n �— a i— n A 14-5 8 O 14 11 17'-6" 6'-10" d -51 WINDOW WINDOW ELL STOOP WELL nn (BELOW (BELOW) U���J�°o N W X WI W 02-22-24 155UED FOR 6'-O" SLIDER 77 OWNERS REVIEW 51�! dJ KITCHEN I 14'-4"x l5'-&" W 000O _ Q FAMILY ROOM 22'-4"xl5'-&" U C7 z tz o o z �t z 000 EP KITCHEN 14'-4"x15'-6" L V. RIEF 0 � • i m 10POWDER - R� O GARAGE m - z T. �X V 22'-0"x22'-O" O 6CS H m N� cam.D X� CL O GO N LIVING ROOM UP DININ6 ROOM 14'-O"xl2'-O" 11'-&"xl2'-2" „ ER OVERHEAD DOOR OVERHEAD DOOR I I Qn w C/ EX. WINDOW EX. WINDOW m Z � IL - COVERED PORCH W Z CD 0 CLf [� if) � U_ __ � N < W z w LL Qn X LU 15'-2" 7'-0" 15'-2" 24'-4" O i ° N 9 o °° a � a paOdCC�4#o 24-00a 9QD HIM, PR0JEGT5 24-00q X1571N& FIR57 I=�CCR PLAN SCALE: 1/4" = I'-O" DG3L°Q�MDIC #o MAIN FLOOR = 1,215 5F GARAGE - 552 5F TOTAL F I R5T FLOOR = 1,767 5F !m[mU mas -4 cf 5 I - gluvF Lao NAMMO La �oLao '' LaQDG{104L C�4 II ��� G�OIaaOC3C� GQ�'JC�[�n`1MC� ', G3��ICG3GJC�LIDg Mn�7 ��g0� �, CU�3�o`r72��7000�44 MEMO ' D r` C STOOP uzguFo EX. WINDOW I EX. WINDOW EX. WINDOW EX, WINDOW 02-22-24 155UED FOR OWNERS REVIEW TUB O O TUB BEDROOM BEDROOM (D:fllo'-&"xl2'-2 J o F x OGL LAV. O. 5 R - - -- LAV. - - — 6e 5D ro co Q 0kp GL C-,L ry� O Go 5'-O" BI-FOLD ry 24 LAV. - --- — N X O k k6a -- X — I V OROOFm MASTER BEDROOM BEDROOM CL m 14'-O"xl2'-O" ry -- - LU —o o W LL _ROOF p r W � lflP W `s) W Z 2'-a° 8'-0" 2'-a" a'-2" 2'-a" 24'-4" X 111 013 CIO 61'-8" Oi � O a L m O � 0 pG30dCD4#o 24-00q 9MD [MME-1 PROJECTS 24-00a X 1571 N6 5 C®N LOOR PLAN SCALE: 1/4" = 1'-0" TOTAL SEGOND FLOOR = 1201 5F DG�LaM�I�[ D#o