Loading...
HomeMy WebLinkAbout50714-Z '�XoF souTyo!° Town of Southold * * P.O. Box 1179 c4 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45905 Date: 01/29/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 6970 Indian Neck Ln Peconic, NY 11958 See/Block/Lot: 86.-7-5.1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 04/05/2024 Pursuant to which Building Permit No. 50714 and dated: 05/21/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Patricia Lowry, John Touhey Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50714 12/2/2024 PLUMBERS CERTIFICATION: tho ' e S gnature �o�S�FFQi�,co TOWN OF SOUTHOLD ay BUILDING DEPARTMENT H : TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 60714 Date: 5/21/2024 Permission is hereby granted to: Lowry, Patricia 262 Garfield PI Brooklyn, NY 11215 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 6970 Indian Neck Ln, Peconic SCTM # 473889 Sec/Block/Lot# 86.-7-5.1 Pursuant to application dated 4/5/2024 and approved by the Building Inspector. To expire on 11/20/2025. Fees: CO-ALTERATION TO DWELLING $100.00 SOLAR PANELS $100.00 ELECTRIC $125.00 Total: $325.00 Building Inspector pE SO�j�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 CA Q sean.devlina-town.southold.ny.us Southold,NY 1 1 97 1-0959 Q Comm BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Patricia Lowry Address: 6970 Indian Neck Ln city:Peconic st: NY zip: 11958 Building Permit#: 50714 Section: 86 Block: 7 Lot: 5.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Service X New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt 2 Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 14.45kW Roof Mounted PV Solar Energy System w/ (34) Hanwha QcellQpeak Qtron M-G2+425 W Modules, Combiner(1)215 (3)220 Breakers,200A Panel 30 Circuits 16 Used , (2) 250 Car Charger Outlets Solar, Service & Carcharger Outlets Inspector Signature: Date: December 2, 2024 69701 nd ianNeckSolarElectric —�- a SOUTyO� `� 71q R rCI �/ .i"'V W'sou V V O * # TOWN OF SOUTHOLD .BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION " [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION' [ ] PRE.C/O [ ] RENTAL REMARKS: J O (ou,-- Ate&; A�o A DATE T cQ q INSPECTOR OF SOGlyolo �® / I1-f V q 70 # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ]..FINAL [ ] FIREPLACE & CHIMNEY [ ' ] -FIRE SAFETY INSPECTION- [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: P-0- c � Fp V) L4 c AqeA rIN C, Az^&4A )- 'v 4- f e r it v �-� t,,- / r� DATE INSPECTOR. Of SOUTyO� * # TOWN OF SOUTHOLD BUILDING-DEPT. o�+� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL %14 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Ov (0511 I h � L 4 DATE INSPECTOR # apF SOUIyo �10UTH TC) TN 0LD B I D7 G ��y000Hi1�,0 631-765-1802 INSPECTION [ ] FOUNDATION .1 ST/ REBAR [ ] ROUGH PLBG. [. ] FOUNDATION 2ND [ ] INSULATION/CAULKING ( ] FRAMING/STRAPPING [ ] FINAL [ ]. FIREPLACE &.CHIMNEY [ ] FIRE,SAFETY INSPECTION . [ ] FIRE RESISTANT CONSTRUCTION [: ] 'FIRE-RESISTANT PENETRATION [ ] ELECTRICAL-(ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL, 'REMARKS: ��1 4 2 Lc DATE 1211,2312 INSPECTOR Page 1 of 1 i Southold town C D v ® Current 01/03/2025 4 2025 Renewables BAN Engineering BAJF�(�Ia'4a Subject: Structural Observation Report u''ho`d Job: Lowry Residence Project Address: 6970 Indian Neck Lane, Peconic, NY, 11958 Attn.: To Whom It May Concern After inspecting the installation of the above referenced project, it is the opinion of Current Renewables Engineering to certify that to the best of our knowledge, belief, and professional judgment the PV installation is in conformance with the Structural Calculations. Verification of all relevant installation methods and materials was provided by ELEMENT ENERGY LLC.. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. .��0F NEw y Zq,yQ.p� Current Renewables Engineering Inc. Professional Engineer = CID info@currentr6newableseng.com r'n 101084 p'�'FE 10NP Exp.01/31/2028 Signed on:01/03/2025 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com FIELD INSPECTION REPORT DATE COMMENTS Q' FOUNDATION(1ST) ------------------------------------ C FOUNDATION (2ND) • z �o 0 H ROUGH FRAMING& PLUMBING S SIN r INSULATION PER N.Y. �y STATE ENERGY CODE S 5 h FINAL 1 ADDITIONAL COMMENTS as 2�4 �a�ok = ✓e c- vP� t#A- �- (,&..Af Ief o `L • 10 •`Lowest. too �� ri lei v cG YY.c1 )b 3 � b 0 x r� H x d b H 1 ."e IF---- TOWN OF SOUTHOLD-BUILDING DEPARTMENT Tomin Hal I Annex 54375 Main Road P. 0. Box 1179 Southold, NY 1 1 97 1-0959 I- i Telephone (63)1) 765-1802 Fax (631) 765-9502 Ear--Ms: wmv.iouthoJd[O%-n. n on Date Received APPLICATION FOR BUILDING PERMIT ) 17\ For Office Use Only "3 PERMIT NO. Building Inspector: APR - 5 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Appillicant not, the vw.ner,, an 2t, Ownees Authorization forra(Page 2)shag be completed. Date: 4 Al Rec eived J 24 OWISVERJS)OF PROPERrY.- Blame: 6-+yY-o4,, L o LA.))1_4 Sum# 1000- 0 —00S. ()0J Project address: , J e CCK "k-/'LJAecoyll'C' 01-4 1 L q59 Phone#: Email: 1P-f—rfA'4;S Mailing Address: (f c9t S CD r ct C-ONTACTPEMN- Name: Lo rrAi'nf Mailing Address: -7 4. q SvuAd atjf.,.� Phone#: 392 --7 0LJ 9 Email: Derr 4,5 co Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMAT10& Name: �I e-rn e,4+ S V)e(-,q Mailing Address: 14V Phone#: 62) 10392 --) D41 Email: 0"s V DESCRIPTION OF PROPOSED CONSTRUCTION I E]NewStructure DAddition DAlteration EIRepair DDemolition Estimated Cost of Pro Fect: 'E5�Qther In64n,-d W&Lf PV ,5�J,--,4-r-k7) $ 4(& 19 1, - Will the lot be re-graded? E]Ye&;gNo Will excess fill be removed from premises? [J-Yes)ZNO PROPERTY INFORMATION Existing use of property: 10iLs . Intended use of property:. S Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to S, this property? ❑Yeso IF YES, PROVIDE A COPY. heck Box After Reading:.-The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Cade.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorked inspectors on premises and in.building(s)for necessary inspections.False statements made herein are punishable as a pass A misdemeanor pursuant to Section 21CAS of the New York State Penal law. i Application Submitted By(print name): �(�Y'�A j�� 1y � authorized Agent ❑Owner Signature of Applicant: Date: LOUIS J ROMEO STATE OF NEW YORK) Notary Public,State of Ne ork No.01 R06314813 SS: Qualified in Suffolk County COUNTY OF Commission Expires November 17,20,% Lof �7"1/4Pri I / ZO Z ru,,-n� {�t,,�,� being duly sworn,deposes and saySthat(s)he Is the applicant (Name of individual signing contract)above named, (S)he is the C- b n (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowleci1lji@1yg6,*fl; ld that the work will be performed in the manner set forth in the application file therewith.:- Notary Public,State of New York No.01 R06314813 Sworn before me this Commission Qualified in s November Suffolk 7,2 / day of, rr 20 Z otary Public ;PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner residing at l9 =t KJ4 K �'vn I'r- 'f" �• !j ���. do hereby authorize Lay, '.{ rti+., E to apply on 4-_t c. . my behalf to the Town of Southold Building Department for approval as described herein. AAA&ZIA g 262 Owner's Signature Date 1 Lt b. L o w Print Owner's-Name 2 BUILDING DEPARTMENT- Electrical Inspector r CZo� Gym TOWN OF SOUT BOLD x Town Mall Annex - 54375 again Road - PO Sox 1179 Southold, New York 11971-0959 y�O ap! Telephone (631) 765-1302 - FAX (631) 765-9502 rogerrC@-southoldtownny.aov- sea nd(cDsoutholdtownny gov APPLICATION FOR ELECTRICAL �NSPEOTION ELECTRICIAN INFORMATION (All Information Required) ®ate: Company Name: Electrician's Name: License N0.: _ f'J t EIec. email: Elec. Phone N0: r , m. )q 13 2 1 request an email copy of Certificate of Compliance Elec. Address.:']1-1 17 1, k, ryl&4-h-bt .r �-1 JOB SITE INFORMATION, (All Information Required) Dame: L()w r Address: �0 TY10�►0,-r �C Cross Street: �, n Phone No.: �y 3 I- "� "l q -� a�� � � � 3 � - v �� --7 D 1_fl Bldg.Permit . 0-1 email. Tax Map District: 1000 Section: d 2 (o Block: 0'-7 Lot: 00 5 BRIEF DESCRIPTION OF WORD, INCLUDE SQUARE FOOTAGE (Tease PrIint Clearly): Ca 0 d 0.m,0� �u'� �✓ S2.Y1/12� re-wia.,ki.� " SI Square Footage: Circle All That Apply. Is job ready for inspection?: YES NO F_�Dough In F] Final ®o you need a Temp Certificate?: YES NO Issued On Temp Informati(on: (All information required) Service SizeF11 PhE]3 Ph Size: A # Meters Old Meter# ❑New Service®Fire Reconnect[]Flood Reconnect❑service Reconnect®Underground verhead ## Underground Laterals 1 R2 H Frame Pole Work done on Service? n Y nN Additional Information: a PAYMENT DUE WITH APPLICATION SQ-vv� � r<<rk- 10`7 t,p s�-- ss0-7 I q Su4riF01 BUI[LDONG DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C x Town Hall Annex - 54375 Main Road - PO Sox 1179 Southold, New York 11971-0959 �s0r,s Telephone (631) 765-1802 - FAX (631) 765-9502 rvgerr�a so€�tholdtoivnn�+_€�o�® - se.an�i; _ APPLICATION FOR ELECTRICAL INSPECTION i ELECTRICIAN INFORMATION (All Information Required) Date: q la Company Dame: e ( MCn4 Er)?,!�- L-iL.C,) Electrician's Name:Uo,� License No.: , �� m Elec. email: Pe r'rn i -3 (a, f, Elec. Phone No: Loa -),o1 L I request an email copy of Certificate of Compliance Elec. Address.: T i-7 o so ave, i n JOB SITE INFORMATION (All Information Required) Nance: AL4601, LOWVI!� � Address: °I1� T"n dr'�n I�l`CCC �Q-✓ CJ V1 t C� �qg � i Cross Street: Phone Flo.: I - 0 It � SIdg.Permit#: JMO 1,0, �/ email: 9ty-r 4s 5,"0) Tax Map District: �1000 = -§ection: D g Block: (D• Lot: (5 0 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply- Is job ready for inspection?: YES 1 ❑Rough In ❑ Final Do you need a Temp Certificate?: YES[2 NO Issued On Temp Information. (All information required) Service SizeF-11 PhF�3 Ph Size: A # Meters Old Meter# []New Service®Fire Reconnect[]Flood Reconnect OService Reconnect❑Underground®Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: 5-ha L I a rat Mai-"I-40— s o I ,— p✓ Spa 1�.�-c,,� ` PAYMENT DUE WITH APPLICATION I o I IrC c-* 0 -7 13 L� . PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TU B/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps 2CO Have () Used (j C) ,SL" Sub Amps Have Used Comments { YTA ycorkers' CERTIFICATE OF INSURANCE COVERAGE STATE i COnlPensatlpn Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that came la.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of insured ELEMENT ENERGY LLC 7470 SOUND AVE MATT' TUC" NY 11952 1c.Federal Employer Identification Number of Insured Work Location,of Insured Onl m ulrad ifcover a is or Social Security Number ! Y 9 ag speciflcailylimited to cedain locations in New York State,i.e.,wrap-up Policy) Carrier (Entity Being Listed as the Certificate Holder) TOWN OF SOUTFi01_D ShelterPoint Life Insurance Company 54375 MAIN ROAD '3b.Policy Number of Entity Listed in Box"W SOUTHOLD,NY 11971 DEL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides the following oenefits: A Both disability and paid family leave benefits. S.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: [Z A.All of the employers employees eligible under the NYS Disability and Paid FamNy Leave Benefits Law. C] B.Only the following class or classes of employers employees: Under penalty of perjury,1 certify that 1 am an authorized representative or licensed agent of the insurance carrier referenced above and fhat tare named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 71117/2023 By f, (5igpature of insurance carrier's authorized representative or NYS licensed Insurance Agent oftt=wsurame carrier) Telephone Number 516-829-8100 Name and T-dle Richard Waite Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU cQwcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plants Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Comlpensation Board(only If moot ae,4C or 56 Have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By Mgrrature of Authorized NYS Workers'Compensation Board Emplayeej j Telephone Number Name and Title J Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance Policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. D13-120.1 (12-21) A ORJfl� CERTIFICATE OF LIABILITY INSURANCE DATE,M 7M,D1 �3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORfl1=D BY THE ER. THIS BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER ROBERT S. FEDE INSURANCE AGENCY NAME: PHONE - FAX 23 GREEN STREET,SUITE 102 No NO: I Na t1UNTINGTON,NY 11743 AO MESS: _ ROBERT S.FEDE INSURANCE INSu S)AFFORDING COVERAGE NAIC 0 INSURER A.ATLANTIC CASUALTY INS.CO. 524210 INSURED Element Energy LLC STATE' DBA ELEMENT ENERGY SYSTEMS I"su>ERc' 7470 SOUND AVENUED' MATTITUCK, NY 11952 04RME: BISURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRI8ED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID'CCAfiNS. INSR LTRtT�fYPE INSURANCE L)Ob ArmL POLICY NUMBER MMIQD EFP Yyn IPPOLICYMME EXP LIMn'9 Ix I ENERAL LIABILITY L1460036873 EACH OCCURRENCE $ 3,000,000 A X X 711412023 7/14/2024 OE OCCUR I PREMISES Ea occurrence S 100,000 X Comlractual Lia MA3692038 Mtn EXP IA are Person) $ 5000 7119J20221 7/1S2024 PERSONAL&ADvINJURY 3 300000O af'>=N'L AGGREGATE LIMITAPPLiES PER i GENERAL AGGREGATE 3 3.000.000 PRO- POLICY X JECT F]LOC PRODUCTS-COMPlOPAGG 3 OTHER: s AUT TB'LEUNBWTY Ecowlwmise > LIMIT i AUTO BODILY INJURY(Par person) $ OvaPtEO SCHEDULED ALfrQS ONLY AUTOS BODILY INJURY(Par ardent) $ HIRED AUPI.O+NN ONLY E fV DAMAGE aUTOS ONLY AUTOS ONLY $ Will 4EMX(C MBREiLA UA9 OCCUR EACH OCCURRENCE $ ESS LIAB CLAAGGREGATEED RETENTION$ 1 WORKERS COMPENSATIoN $ AND EMPLOYERS LIABIITv 124494445 PER OTH- ANY P"FEMPL ETORrFARTNERJEXECUTIve Y 1 td 7113/2023 7113/2024 A EA B OFRN�CERIM MBER EtCLUDE - NIA E.L EACH ACCIDENT $ 1,000,000 If yes,describe under EL DISEASE-EA EMPLOYE $ lowwo DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLH;Y LIMIT $ NY State DBL D13L567527 1/01/2023 12/3112024 Statutory DESCRIPTION OF OPERATIONS t LOCATIONS I VEWCLES fACURO 101,Addtdenal Remarks$dL-dWe,may be ati"bM tf more epaee is r"wradl CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtfiieate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE fcbe tS. Feder C 1988-2015 ACORD CORPORATION. All rights reserved, er ne�rl �s»naRtnZs T§, A!`0110r1 ..a L .. ,. ,,....:es..v..a s...—G..ra Armor, /Vak\ NYSIF New York State Insurance Fund PO Box 68699,Albany,NY 122C6 I nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) AAAAAA 8233366fl4 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD F71 ATE 12449 444-5 369075 0711312023 TO 07/1312024 12023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO, 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY.INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT NTTPS;IIWWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GNE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION ANDIOR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT. THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STTAe SU CE FUND t/ DIRECTOR,INSURANCE FUND UNDERWRITING r6A APpRnvFn AS NOTED DATES FEE / BY: NOTIFY BUILDING DEPARTMENT AT 631.765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REOI flPr-D FOR POURED CONCRETE: 2. ROUGH-FRAMING&PLUN;P, :",;3 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE, NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLD TO ZBA SOUTHOLD OWN PLANNING BOARD SOUTHO TOWN TRUSTEES VS. 0 SO OLD HPC SD OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED Page 1 of 2 Current 04/02/2024 Renewables ELEMENT ENERGY LLC. to Engineering Subject: Structural,Certification for Installation of Residential Solar Job: Lowry Residence Project Address: 6970 Indian Neck Lane, Peconic, NY, 11958 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of ELEMENT ENERGY LLC.. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 �EOF NEW y A. Z4,�'�� Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com y 106793 F NP Signed on:04/02/2024 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x6 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 16 degrees and has a max beam span of 11.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x6 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 32 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com ROOF MOUNT SOLAR PERMIT PACKAGE CODE INFORMATION THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: -, , PATRICIA LOWRY y. i 2020 NEW YORK BUILDING CODE-BUILDING nLE'n 14.450 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-RESIDENTIAL 2020 NEW YORK BUILDING CODE-EXISTING BUILDING 2020 NEW YORK BUILDING CODE-PLUMBING Exp:09/30/2025 MAY 2 1 2024 2020 NEW YORK BUILDING CODE-MECHANICAL QF NEW 70 I N D I A N NECK LN, P E CO N I C, NY 11958 2020 NEW YORK BUILDING CODE-ENERGY CONSERVATION �P90 A. y0� 2020 NEW YORK BUILDING CODE-FUEL GAS oO� �qof, 2020 NEW YORK BUILDING CODE-ACCESSIBILITY BUILDING INFORMATION 2020 NEW YORK FIRE PREVENTION CODE 2017 NEW YORK NATIONAL ELECTRICAL CODE = THESE DRAWINGS ARE SUBJECT TO y� COPYRIGHT PROTECTION BY US LAW. 2 STORY HOUSE SINGLE FAMILY RESIDENCE �� 106793 �� REPRODUCTION IN ANY FORM IS ACCOUNTNO. : 9641541206 �O `\ � EXPRESSLY FORBIDDEN WITHOUT PRIOR F \`P / WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U AHJ : TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC ROOF:COMPSHINGLE APN:1000086000700000000 METER NO: 98300265 Signed on:04/02/2024 PV SYSTEM SUMMARY: WIND SPEED 128 Current SYSTEM SIZE(DC) STC:425 x 34= 14.450KW DC STRUCTURAL NOTES : SNOW LOAD 25 Renewable PTC: 395.25 x 34= 13.4385KW DC 1. THESE PLANS ARE STAMPED FOR STRUCTURAL EXPOSURE CATEGORY D Engineering SYSTEM SIZE (AC) 9.860KW AC @ 240V CODE COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE PROPOSED PV INSTALLATION ENGINEERING INC.ABLES MODULES (34)HANWHA CICELLS CITRON BLK M-G2+425W ENGINEERING IN ONLY. 1760 CHICAGO AVE SUITE CA 2. THESE PLANS ARE NOT STAMPED FOR WATER PHo EIV951S)-405-1733IDE 507 LEAKAGE. www cRENc co MICRO-INVERTERS ENPHASE: ICI8PLUS-72-2-US 3_ PV MODULES, RACKING,AND ATTACHMENT AERIAL VIEW VICINITY VIEW CONTRACTOR INFO MICRO-INVERTERS CITY 34 COMPONENTS MUST FOLLOW MANUFACTURER TILT 16°, 32' GUIDELINES AND REQUIREMENTS. AZIMUTH 235°, 145' 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL 1 a" ROOF COMP SHINGLE CALCULATIONS REPORT FOR ADDITIONAL Ln R0 a Im INFORMATION. CcSYS0 RAFTER/TRUSS SIZE 2"X6"RAFTER @ 24"O.C. 5. PRIOR TO COMMENCEMENT OF WORK, THE ATTACHMENT TYPE IRONRIDGE HALO ULTRA GRIP WITH IRONRIDGE SOLAR INSTALLER SHALL VERIFY THE ROOF XR-100 FRAMING INFO BEFORE INSTALLATION AND NOTIFY 9 CIF ELEMENT AVENUE, LLC. 7470 SOUND AVENUE,MATTfTUCK, MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH 200 AMPS MAIN THE E.O.R. IF THERE IS ANY INCONSISTENCY NEW YORK,11952 BREAKER ON TOP FED BETWEEN SITE VERIFICATION AND FOLLOWING: 2x6 PH:(631)7797993 RAFTERS @ 24" OC SPACING WITH MAX services@e2sys.com INTERCONNECTION LINE SIDE TAP Licence--ME-5 ME-5268989 OCPD RATING 60 AMPS UNSUPPORTED SPAN EQUAL OR LESS THAN 14 FT. (MASTER ELECTRICIAN) Licence-HI-67461 UTILITY LONG ISLAND POWER AUTHORITY (SUFFOLK HOME IMPROVEMENT) GENERAL NOTES: Solar Individual � „ � �� A Permit Package 1 LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION 2 THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED SHEET INDEX PATRICIA LOWRY 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED" 5 ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 1 4.450KW Grid Tied 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8, THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PV-3.0 STRUCTURAL 6970 INDIAN NECK LN, 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE PECONIC,NY 119S8 MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PV-4.0 ELECTRICAL 3LD 11, A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS Rev Desaiption IDate 12 MAX HEIGHT OF MODULES OFF OF ROOF FACE.<6" PV-5.0 ELECTRICAL SLD A INITIAL DESIGN 41212D24 13 PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. PV-7.0 ELECTRICAL PHOTOS 15, MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. OPPORTUNITY PATRICIA LOWRY 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PV-8.0 SIGNAGE PROJECT# 8866 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.1 PLACARD DATE DRAWN 41212024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/81,ABOVE ROOF SURFACE. PV-9.0 M ICROI NVERTER CHART DRAWN BY ER 19, IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE,TYPE NM CABLE PV-100 SAFETY PLAN SHEET PV-1.0 . ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0 SAFETY PLAN 20 MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: PV-1 2.0+ SPEC. SHEETS R324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND SEPARATE ROOF PLANES. ENLARGED VIEW FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. INDIAN NECK L N FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM MSP MAIN SERVICE PANEL 361NCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE INDIAN NECK L N AC DISCONNECT OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS 64=)„ WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR I �� MECHANICAL EQUIPMENT. I COMBINER (E) UTILITY METER R324.6.2 SETBACK AT RIDGE: I u FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 MODULE PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A i a �— PROPERTY LINE HORIZONTAL RIDGE. I i.; \` THESE DRAWINGS ARE SUBJECT TO FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 i ROOF OBSTRUCTIONS COPYRIGHT PROTECTION BY US LAW PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A i I i MSP UM REPRODUCTION IN ANY FORM IS I t EXPRESSLY FORBIDDEN WITHOUT PRIOR 36 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A I , i �} ROOF ACCESS POINTAPPRVAL FROM HORIZONTAL RIDGE. ; i 1`� t` AC ! ERNEWABLES ENO GINEERING INC CURRENT R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS I i ��`��` TRENCH CONDUIT AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE ' PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. I I Rer` A -PATHWAY ON STREET I i (N) FUSED AC DISCONNECT Engineering OR DRIVEWAY SIDE OF ROOF ' B FIRE ACCESS POINT (E)MAIN SERVICE PANEL CURRENT RENEWABLES Exp:09/30/2025 ENGINEERING INC. C 1760 CHICAGO AVE SUITE 36"ACCESS PATHWAYS OF NEW WOO/Mr/m/2 _ '�4 y PHONEV(95SI<OS-1733507 i •`P Rt A. OA NM1NW.CRENG.CO N �De� `���?* CONTRACTOR INFO 18"ACCESS PATHWAYSRENE , 00 NOTES: gy 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND I ' 106793 �V MEASUREMENTS. 863'-1" ����� 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED INTO THE 2017 NEC AND UL I (N) 1" PVC UNDER GROUND I STANDARD 1741. ( _ CONDUIT @ 18"BELOW ' ZO Signed an 04ro2a024 ELEMENT ENERGY LLC. 3. EXISTING ROOF VENT SHOULD NOT BE GRADE-150'(TRENCHED) 7470 SOUND AVENUE,MATTITUCK, COVERED. I CN NEW YORK,11952 ' I PH:(631)779 7993 services@e2sys.com i Licence-ME-52689 I' I (MASTER 6 RELECTR��AN) i (SUFFOLK HOME IMPROVEMENT) ' FENCE Solar Individual Permit Package I � ROOF OBSTRUCTION PATRICIA LOWRY SHED 14.450KW Grid Tied ROOF ACCESS POINT y ' Photovoltaic System (N)AC DISCONNECT j 6970 INDIAN NECK LN, s � (N)COMBINER PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2D24 ROOF LINE I' DRIVEWAY PROPERTY LINE = OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 • DATE DRAWN 4/2/2024 SITE PLAN 00 I 31' 10" ROOF ACCESS POINT DRAWN BY ER N , CC SHEET# PV-2.0 1 57'-6 TITLE SCALE: 1/128" = V-0" —�® S2--fi SITE PLAN ARRAY AREA LEGEND ` EAVE TO ROOF ROOF TOTAL #OF RIDGE ARRAY AREA AREA AREA ROOF ROOF TYPE AZIMUTH AREA MODULES DIMENSION (Sq.Ft.) COVERED BY COVERED BY (Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) UM UTILITY METER #1 COMP SHINGLE 235 7 11.4 147A4 2701 5.45 #2 COMP SHINGLE 1 145 27 14.10 567.54 2701 21.01 26.46 MSP MAIN SERVICE PANEL �c AC DISCONNECT INDIAN NECK LN c❑ COMBINER (E) UTILITY METER a MODULE ROOF OBSTRUCTIONS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR TRENCH CONDUIT WRITTEN APPROVAL FROM CURRENT MSP UM RENEWABLES ENGINEERING INC. 1 t t It ) t I 1 I` AC Current Renewables - Engineering (N) FUSED AC DISCONNECT Exp:09/30/2025 CURRENT RENEWABLES ENGINEERING INC. of NEW 1, 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 (E MAIN SERVICE PANEL �Q RSA O,Q PHONE (951(dOS1733 ) �Q�O� �qOF� WWW.CRENG.CO +t * CONTRACTOR INFO r W y ? A 106793 4 ARM F NP E z SYSA " C UNDER GROUND Signed on 04102/2024 (N) 1 PVC ELEMENT ENERGY LLC. CONDUIT @ 18"BELOW 7470 SOUND AVENUE,MATTRUCK, GRADE-150' (TRENCHED) NEW PORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, ROOF#1 PECONIC,NY 11958 (N)COMBINER Rev Description Date A INITIAL DESIGN 402024 (N)#34 HANWHA QCELLS Q.TRON BLK E M-G2+425W OPPORTUNITY PATRICIA LOWRY PROJECT# e866 ROOF#2 DATE DRAM4/2/2024 ROOF PLAN DRAWN BY ER 2 SHEET# PV-2 1 TITLE SCALE: 1/32" = V-O" ROOF PLAN ROOF ROOF ROOFING FRAMING FRAMING OC PENETRATION MAX MAX NO TILT TYPE ATTACHMENT TYPE TYPE SIZE SPACING PATTERN PENETRATION SPACING OVERHANG ROOF 1 16 COMP SHINGLE IRONRIDGE HALO ULTRA GRIP RAFTER 2"X6" 24" STAGGERED 72" 24" ROOF 2 32 COMP SHINGLE IRONRIDGE HALO ULTRA GRIP RAFTER 2"X6" 24" STAGGERED 72" THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current 16 Renewables Engineering HANWHA QCELLS Q.TRON BLK M-G2+425W CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE IRONRIDGEXR 100 J-13,RIVERSIDE CA92507 TABLE PENETRATION PHONE(951)d05-1733 WWW.CRENG CO GUIDE FOR INSTALL CONTRACTOR INFO 4, (E)COMP SHINGLE TWO OR MORE ROWS OF PANELS zs r41N.eMBED. IRONRIDGE HALO ULTRA GRIP CZSYS I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ELEMENT ENERGY LLC. #14 X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING 7470 souNo AVENUE,MATrrrucK, RAFTER NEW YORK,11952 Exp:09/30/2025 3PH:(631)779 7993 services@e2sys.com *, e��OF NEcy (E)2"X6"RAFTER@ 24"O.C. (MASTER ELECTRICIAN) ENLARGED VIEW �oat A. Licence-HI-67461 (SUFFOLK HOME IMPROVEME NT)I IRONRIDGE XR-100 r W STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE HALO ULTRA GRIP Permit Package �0 106793 ONE ROW OF PANELS HANWHA QCELLS Q.TRON BLK M-G2+425W A NP PATRICIA LOWRY SEE ENLARGED VIEW - i— Signelion.04A22024 14.450KW Grid Tied I I I I I I I I I I I I I Photovoltaic System (E)2"X6"RAFTER@ 24"O.C. I I I I I I I I I I I I I 6970 INDIAN NECK LN, PECONIC,NY 11958 FULLY STAGGERED STACKED/STAGGERED Rev Description Date ATTACHMENT DETAILS (E)COMP SHINGLE A INITIAL DESIGN 412/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8966 DATE DRAWN 4/2/2024 DRAWN BY ER SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.21A @ 240V ACCOUNT NO. : 9641541206 41.14 X 1.25 = 51.43AMPS 60A FUSES-OK Al NE(.�yp METER NO: 98300265 ��OQEMA CO /yj�GZ m w oss128 2 (E)UTILITY METER yN�O CTRtGP� (E)200A RATED (N)ENPHASE MAIN SERVICE PANEL rOFESSION COMBINER BOX MODEL iPH,1201240V 60HZ NO#X2-IQ-AM1-240-4/4C (E)200A/2P MAIN ® STAMPED 04/02/2024 2-#12 AWG,SKU.0-12-RAW-300,THHN BREAKER 1-#8 AVVG,BARE COPPER GROUND (TOP FED) CELL WIRE LESS THESE DRAWINGS ARE SUBJECT TO (12)IQ8PLUS-72-2-US MODEM COMMS MICROINVERTERS I COPYRIGHT PROTECTION R IS LAW. REPRODUCTION IN ANY FORM IS 10 GATEWAY EXPRESSLY FORBIDDEN WITHOUT PRIOR BRANCH-1 WRITTEN APPROVAL FROM CURRENT 12 HANWHA QCELLSQ.TRON RENEWABLES ENGINEERING INC. BLK M-G2+425W r (N)60A FUSED (1 1)I08PLUS-72-2-US AC DISCONNECT MICROINVERTERS I (N)20A SQUARE DD322NRB (N)LINESIDE TAP VIA UL WITH 60 A FUSES, LISTED CONNECTOR Current KNIFEBLADE, BRANCH-2 I (N)20Am LOCKABLE,NEMA 3R, Renew abi e s tt HANW M-G2+4LSQTRON _ ___ /� ULLISTED Engineering BLK M-G2+425W f (N)20� I ' � I /� I � To unuTY I HIP— Er OVERHEAD (11)IQ8PLUS-72-2-US — ———————— — e L-----——— MICROINVERTERS I L———— I CURRENT RENEWABLES ENGINEERING INC. BRANCH-3 I 3-#B AWG. 1760 CHICAGO AVE SUITE THWN 3-#6 AWG.THWN I J-13,RIVERSIDE CA 92507 BLK M 425W -G2+ 25W 1 HA GCE RON __ --_—J 1-#8 EGC,THWN 1-#8 EGC,THWN PHONE.(951)-4057733 BLK � IN 1"PVC UNDER IN 3l4"OR LARGER PVC L——— ———— WWW.CRENG.CO GROUND CONDUIT @ 18" CONDUIT BELOW GRADE-150 CONTRACTOR INFO (TRENCHED) (E)GROUNDING ELECTRODE CONDUCTOR#6 COATED COPPER a a r*1 MODULE MANUFACTURER QCELLS C2SYS9 MODULE MODEL Q•TRON BLK M-G2+425 W ELEMENT ENERGY LLC. MODULE(W) 425 7470 SOUND AVENUE,MATTITUCK, MODULE PTC(W) 395.25 NEW YORK,11952 PH:(631)779 7993 MODULE Isc(A) 13.66 services@e2sys.com Licence-ME-52689 MODULE Voc IV) 39.03 (MASTER ELECTRICIAN) MODULE Imp(A) 2.98 Licence-HI-67461 MODULE Vmp IV) 32.74 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A PATRICIA LOWRY WIRE SCHEDULE STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 14.45OKW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT Photovoltaic System # EQUIPMENT WIRE LOCATION QTY. WIRE AMPACITY RATING (°C) FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 6970INDIAN NECK LN, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY PECONIC,NY 11958 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.66 0.96 1 28.80 17.08 Rev I Description I Date A INITIAL DESIGN 1 4/2/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 14.52 0.96 1 28.80 18.15 3 AC COMBINER TO FUSED AC DISCONNECT TRENCH 3 8 55 90° 41.14 0.96 1 52.80 51.43 OPPORTUNITY PATRICIA LOW RV 4 AC FUSED AC TO POI EXTERIOR WALL 3 6 75 90° 41.14 0.96 1 72.00 51.43 PROJECT# 8866 DATE DRAWN 4/2/2024 DISCONNECT DRAWN BY ER SHEET# PV-4.0 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.21A @ 240V 41.14 X 1.25 = 51.43AMPS 60A FUSES-OK ACCOUNT NO. : 9641541206 OF NEpV J'O METER NO: 98300265 CO UjMA v w m w 099128 = (E)UTILITY METER CTRIGP\' (E)200A RATED ARO SS1oNP� (N)ENPHASE MAIN SERVICE PANEL COMBINER BOX MODEL PH,120240V 60HZ STAMPED04/02/2024 NO#X2-IQ-AM1-240-4/4C (E)200A/2P MAIN ® 2-#12 AWG.SKU:O-I2-RAW-300 7HHN BREAKER 1-#8 AWG,BARE COPPER GROUND (TOP FED) CELL WIRE LESS THESE DRAWINGS ARE SUBJECT TO (12)IQBPLUS-72-2-US — MODEM COMMS COPYRIGHT PROTECTION BY US LAW. MICROINVERTERS REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR BRANCH-1 _ IQ GATEWAY WRITTEN APPROVAL FROM CURRENT 12 HANWHA pCELLSp.TRON NV RENEWABLES ENGINEERING INC. BILK M-G2+425W N)15A: (N)60A FUSED (11)Ip6PLUS-72-2-US AC DISCONNECT MIBPLUSERTERS (NUOA,m SQUARE D D322NRB (N)LINESIDE TAP VIA UL WITH 60A FUSES, LISTED CONNECTOR Current KNIFEBLADE, RQIi,�W�MG S BRANCH-2 (N120:�jC. LOCKABLE,NEMA 3R, 11 HANWHAQCELLSQ.TRON Engineering N UL LISTED ELK M-G2+425W (N)20;T /'� ./,yam. TO UTILITY iID OVERHEAD (11)IQBPLUS-72-2-US -- vf! FEED CURRENT RENEWABLES MICROINVERTERS ENGINEERING INC. 1760 CHICAGO AVE SUITE BRANCH-3 J-13.RIVERSIDE CA 92507 11 HANWHA QCELLSQ.TRON N 3-#8 AWG,THWN 3-#6 AWG.THWN (951)-405-1733 BILK M-G2+425W 1-#8 EGG,THWN 1-#8 EGC,THWN PHONE IN 1"PVC UNDER IN 314"OR LARGER PVC WWW.CRENG.CO GROUND CONDUIT @ 18" CONDUIT CONTRACTOR INFO BELOW GRADE-150' = (E)GROUNDIN ELECTRODE (TRENCHED) CONDUCTOR#6 BARE COPPER ,a ® r*1 MODULE MANUFACTURER QCELLS CZSYS MODULE MODEL Q•TRON BILK M-G2+425W ELEMENT ENERGY LLC. MODULE(W) 425 7470 SOUND AVENUE,MATTITUCK, MODULE PTC(W) 395.25 PH:(63)7 791 993 MODULE Isc(A) 13.66 services@e2sys.com Licence-ME-52689 MODULE Voc IV) 39.03 (MASTER ELECTRICIAN) MODULE Imp(A) 2.98 Licence-HI-67461 MODULE Vmp(V) 32.74 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A PATRICIA LOWRY WIRE SCHEDULE STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 14.450KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CORRECTION CURRENT FACTOR FOR ADJUSTED CURRENT Photovoltaic System EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO # QTY. AMPACITY RATING (°C) FACTOR SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 6970INDIAN NECK LN, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY PECONIC,NY 11958 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.66 0.96 1 28.80 17.08 Rev Description Date A INITIAL DESIGN 4/2/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 14.52 0.96 1 28.80 18.15 3 AC COMBINER TO FUSED AC TRENCH 3 8 55 90° 41.14 0.96 1 52.80 51.43 DISCONNECT OPPORTUNITY PATRICIA LOW RV FUSED AC PROJECT# 8866 4 AC TO POI EXTERIOR WALL 3 6 75 90° 41.14 0.96 1 72.00 51.43 DATE DRAWN 4/2/2024 DISCONNECT DRAWN BY ER SHEET# PV-5.0 TITLE ELECTRICAL SLD MATERIAL LIST OF NEB, y ELECTRICAL EQUIPMENTS �oDEMA/yjQC�.Q* QTY. PART TYPE PART NUMBER DESCRIPTION r D W 34 MODULE Q.TRON BLK M-G2+ 425W QCELLS Q.TRON BILK M-G2+425W %, 099'28 w 34 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US ��,o cTRIGP` 1 I FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 311 UL LISTED RO�SS►oNP� 1 COMBINER X2-1Q-AM1-240-4 ENPHASE COMBINER BOX X2-IQ-AM1-240-4 STAMPED04/02/2024 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewable Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-005-1733 WWW.CRENG.CO BREAKER / FUSES CONTRACTOR INFO QTY. PART TYPE PART NUMBER DESCRIPTION 1 FUSES 60A FUSES GENERAL 60A FUSES 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) E2SYS9 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 RACKING (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 40 RAILS & SPLICES XR-100-168B XR100, RAIL 16811 BLACK Permit Package 26 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 PATRICIA LOWRY 82 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK 28 CLAMPS & GROUNDING UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK 14.450KW Grid Tied 7 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE Photovoltaic System 129 ATTACHMENTS FF2-02-132 FLASHFOOT2, BLACK 6970INDIAN NECK LN, PECONIC,NY 11958 Rev I Description Date A INITIAL DESIGN 4/2/2024 L PATRICIA LOWRY 9 4/2/2024 E.R PV-6.0 BOM EXISTING SERVICE PANEL PHOTOS OF NEW ' MALU /y�� D W m w 099128 2 4 CT IC, ��C9 ARO�ss►oNP� STAMPED 04/02/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO CONTRACTORINFO EZSYSAU ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 OPFservices@e2sys.com § Licence-ME-52689 i (MASTER ELECTRICIAN) Licence-HI-67461 - ar (SUFFOLK HOME IMPROVEMENT) �~ Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, m PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 4/2/2024 DRAWN BY E.R SHEET# PV-7.0 TITLE ELECTRICAL PHOTOS OF NEW _ MA/V/, O'p� PHOTOVOLTAIC SYSTEM, M * � . �z * W • '- � - � - � �• m � D99128 v i 690.12 ! I ZN�O CTRIGP`" u ADO SS1ONP� STAMPED 04/02/2024 THESE DRAWINGS ARE SUBJECT TO LCOPYRIGHT BY US TURN RAPID PV SYSTEM AC DISCONNECT REPRODUCTION NEANYOFORM IS LAW EXPRESSLY FORBIDDEN WITHOUT PRIOR SHUTDOWN SWITCH TO , OUTPUT CURRENT- - WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC THE "OFF" POSITION TO AC - - AC NOR OPERATING VOLTAGE 4' VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current AND REDUCE SHOCK "WA_ - Renewakles HAZARD IN THE ARRAY PM DUAL POWER • - Engineering 690.56(C)(1)(B) SECOND SOURCE PHOTO-VOLTAIC CURRENT RENEWABLES ENGINEERING INC. OUTPUTRATED AC 1 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 •'MAL OPERATING VOLTAGE 1 •LTS PHONE:(951)-405-1733 AC NWWW.CRENG.CO CONTRACTORINFO 690.54 OPTIONAL SOLAR LOAD CENTER n ARRAY a im r*1 EZSYS8U ELEMENT ENERGY LLC. J/B 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 . services@e2sys.com Licence-ME-52689 INVERTER • ' • • (M ASTER Licence- I 6 R ELECT7ICIAN) 461 (SUFFOLK HOME IMPROVEMENT) O NOT RELOCATE NEC 690.31(G)(3)&(4),CRC R324.7 • "WA _ Solar Individual (UNLESS BUSBAR IS FULLY RATED) L — Permit Package 705.12(D)(2) PHOTOVOLTAIC POWER SOURCE PATRICIA LOWRY EVERY 10'ON CONDUIT AND ENCLOSURES 14.450KW Grid Tied Photovoltaic System NOTES. 6970INDIAN NECK LN, PECONIC,NY 11958 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. Rev Description Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 4)2/2024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OPPORTUNITY PATRICIA LOW RV B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. PROJECT# 8866 C. AERIAL FONT. DATE DRAWN aiv2oza R. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN SHEET#DRAWN BY E ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. of NEt7,Y �P 0QE Mq/V/, M D W m oss12s 2 ZN�O 4 C TR(CP�' ARO SS►oNP� CAUTION STAMPED 04/02/2024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewabies Engineering CURRENT RENEWABLES ENGINEERING INC. PV ARRAY 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG.CO Z CONTRACTORINFO J ]C U w a ®� Z Z _ 0 MAIN SERVICE PANEL C Z SYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, A'C DISCONNECT NEW YORK,11952 [COMBINER AC DISCONNECT PH:(631)779 7993 services@e2sys.com UTILITY METER Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PATRICIA LOWRY PANEL IS AC DISCONNECT PER NEC690.17 14.450KW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, PECONIC,NY 11958 Rev Desalptlon I Date A INITIAL DESIGN 1 4/2/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8966 DATE DRANK 4/2/2024 DRAWN BY E.R SHEET# PV-8 i TITLE PLACARD MICROINVERTER CHART 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current Renewables Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE(951)-405-1733 WWW.CRENG.CO CONTRACTORINFO 5 a IN r*1 EZSYS8 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 6 NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied 8 Photovoltaic System 6970INDIAN NECK LN, PECONIC,NY 11958 Rev Desaip6on I Date A INITIAL DESIGN 4/2/2024 9 OPPORTUNITY PATRICIA LOWRY PROJECT# 6966 DATE DRAWN 4/2/2024 DRAWN BY E R 1 0 SHEET# PV-9.0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS.- THESE DRAWINGS ARE SUBJECT TO ❑c COMBINER COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. EXPRESSLY FORBIDDEN WITHOUT PRIOR 2.SAFETY PLAN MUST BE MARKED BEFORE JOB AC AC DISCONNECT WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN RENEWABLES ENGINEERING INC 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE MSP MAIN SERVICE PANEL &MAKE NOTES ON THE JHA SHEET UTILITY METER Current IN CASE OF EMERGENCY Renewables NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC OP PERMANENT ANCHOR Engineering CURRENT RENEWABLES NAME: ENGINEERING INC. O TEMPORARY ANCHOR 1760 RIVERSIDE AVE SUITE ADDRESS: PH E(951IDE CA-1733 7 PHONE(951)d05-1733 IL INSTALLER LADDER WWWCRENG°° SAFETY COACH CONTACT INFORMATION CONTRACTOR INFO S❑ NAME: STUB-OUT ADDRESS: ® SKYLIGHT ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE v` NO LADDER ACCESS (STEEP GRADE EZSYSgu SAFETY PLAN AND SIGN INDICATING THAT THEY ARE Li OR GROUND LEVEL OBSTRUCTIONS) AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. RESTRICTED ACCESS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTfrUCK, NAME SIGNATURE TRENCH HE(630R791 993 GAS GAS SHUT OFF services@e2sys.com Licence-ME-52689 zo WATER SHUT OFF (MASTER MLic nReLHC6R461 O (SUFFOLK HOME IMPROVEMENT) SERVICE DROP O POWER LINES Permit Individual it Package PATRICIA LOWRY 14.450KW Grid Tied Photovoltaic System 6970INDIAN NECK LN, PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 DATE TIME OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 4/2/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. • The safety of the Client and the Public must be maintained at all The site supervisor shall forecast the weather conditions at the Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below).If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure. Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with COPYRIGHT PROTECTION S LAW. REPRODUCTION IN ANY FORM IS S uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC the ladder must extend 36"above the stepping off point. Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. Elevated work involving the moving or maneuvering of solar • If Offsite,add location name and address: bars locked in the open position,A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind t , Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure leaned a ainst a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor (} i= • wables Additional notes: • Crew leader responsible for communication with the client: - Engineering Name: Mobile Equipment Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment,operators must Yes, No): Heat Related Illness Prevention Phone: CURRENT RENEWABLES maintain a certification on their person for the equipment bein Employees shall have access to potable drinking water that is ENGINEERING INC. pgP 9 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13.RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): • All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE(951)-405-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: VJW W.CRENG.CO • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift. Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.TheAlan* roof will be physically protect from failing or sliding off. r frequent drinking of water shall be encouraged. Name: • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees C SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: q • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete;a fall rescue plan must be outlined and Crew member(name/title): New employees must be acclimatized. New employees will be of what happen and when. 7470 SOUND AVENUE,MATTITUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and connect Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof Crew member(name/title): scheduled breaks during each shift. Employees must take Licence-ME-52689 uninstallin fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-HI- 67461• Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an PATRICIA LOWRY electrically safe condition(de-energized)unless approval has If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work, all employees on site? 14.45OKW Grid Tied • Service drops and overhead electrical hazards will be If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: indentified and protected from contact as neccessa water(location/address): Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 6970 INDIAN NECK LN, PECONIC,NY 11958 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 4/2/2024 L PATRICIA LOWRY 8866 4/2/2024 E.R PV-11.0 SAFETY PLAN Q.TRON BLK In r: In `RUN BLK M-G2+ SERIES 3 s ■Mechanical Specification .,ram.n ,.e-raa.q SERIES Format 678 inx 44.61n x 1 18 in(including frame)MONS (1722mm x 734mm x 30mm)M-G2+ _ 11111ifight 4671bs(21.2 kg) I From Cover 0.13 in(32 min)thermally pre-stressed glass :a.lrwa..r .xre�-a with aritkefleCdOn technology 405-425 Wp 1108 Cel Is Bade cover Composite film Frame Black aodised aluminium - 21.8 p� Maximum Module Efficiency n-- -- Cell 6 x 18 monocrysMiline O ANTUM NEO solar hat cells -4-1 m...r THESE DRAWINGS ARE SUBJECT TO Junction box 2.09-3.98in x 126-236mx 0.59-0.71in (53-tOlmm x 32-60mm x 15-18mm),Protection class IP67,with bypass diodes °°�" ��--iiJJ COPYRIGHT PROTECTION BY US LAW. _ - REPRODUCTION IN ANY FORM IS Cable 4mm'Solar cable;(+)a68.91n(1750mm).H?68.9in(1750mm) a�l.�. EXPRESSLY FORBIDDEN WITHOUT PRIOR Connector Staublf MC4:IP68 ,,,.a„.�I�~- T��-h WRITTEN APPROVAL FROM CURRENT MODEL O.TRON BLK M-G2+ RENEWABLES ENGINEERING INC. ■Electrical Characteristics ----- --- -- POWER CLASS ,os .m 415 .20 42S Current "pfdo RFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWE R TOLE RANCE>5Wt-0 W) t.`.i�ewabies ` Power a t MPP' Pure rM 405 410 415 420 425 11 Q.HNTUM High performance Qcelis N-type - Short Circuit Current' - - 1� [A] 13.33 13.49 DS8 13.66_ Engineering ti.41 N=0 solar cells zE Open Circuit Voltage' Vac M 37.91 38.19 3&47 3875 39.03 CIANTUM NEO Technology with optimized module layout Z Current at MPP I.- [A] 1269 1276 12.83 12 91 12.98 CURRENT RENEWABLES boosts module efficiency up to 21.8 ��at MPP He__--- r M . - 31.93 32.13 32.34 32-54 32.74 ENGINEERING INC. %. Ef6cienty - _- - -- n [%I k207 a21.0 km k21.5 221.8 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 25 A reliable investment MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' WWW CRENG CO Inclusive 25-year product warranty and 25-year linear Power at MPP P..ee Im 3061 309.9 313.7 317.5 32t2 CONTRACTOR INFO Yllarroall Slerformance warrants. E it Circuit Cwmt I.c [A] 10.74 1021 10.87 10.94 1L00 E Open Circuit Volbga Va M 35.96 36.23 36.50 3677 37.04 f current at MPP 4.e [Al 0.66 027M04 1.07 10.15 1.46 'i 0.21 Enduring high performance v�geriMPP Vr.x M 30.66 3os7 31.07 31.26 31.4s 'Measurement tolerances Pre+3%;iso Vol,t 5%at STC:1000 WIM2,25t 2°C.AM 1.5 according to IEC 60904-3.2800 W/m',NMOT,spectrum AM 1.5 e• Long-term yield security with Anti LeTID Technology.Anti PID a a nt ?c Technology2,Hot-Spot Protect C P SYSu OeeMs PERFORMANCE WARRAtfTY PERFORMANCE AT LOW/iRAD1ANCE tin w At least 98S%of n0lmnal power A �` �•--••• duringfrstyear.Thereaftermax. ELEMENT ENERGY LLC. Extreme weather rating . --------- o.33%degradationpetyear.AI y 7470 SOUND AVENUE,MATTRUCK, /,7j least95.53%ofrxxr'i"a'power W s° ____" NEWYORK,11952 YY High-tech aluminium alloy frame.certified for p up to 10 years.At 1=9'0.56%of high snow(5400 Pa)and wind loads(5400 Pa) z nominal power up to 25 years. PH:(631)779 7993 a o services@e2sys.com y C s All data with.meesutemem tolerances.Fun warranties m Licence-M E-52689 �g accordance with the warranty z (MASTER ELECTRICIAN) �^( Innovative all-weather technology S a tenths of the ocelis sales b Licence-HI-67461 C c 0 as c +s n a organisation of your respective ,po .po am .00 vm Optimal yields,whatever the weather With excellent low-light .EARS country. RRADIARCE w;m° (SUFFOLK HOME IMPROVEMENT) and temperature behaviour Sendwd terms W gunrx,ner lo,trr 5 W companies wits the Typsel module peeormn,rr uMer low imadia„ce rnnennm in iv Ngiv,vaoducl cxux y 7021Irebr ,,,2021) pmpa,rsontuSTCCad ohsf75-C I000-1 Solar Individual nThe most thorough testing TEMPERATLtaaCOOV+cN3M Permit Package 1�1 Temperature Coefficient of I.c a 1%i Kj �004 Temperature Coefficient of V,�, 3 !K 024 programme in the industry x II//WVV Temperature Coefficient of PAW y [%/K] -0.30 Nominal Module OperatingTemperature NMOT f 109i 54 Oceils is the first solar module manufacturer to pass the (43t3°q PATRICIA LOW RY most comprehensive quality programme in the industry.The j new'Quality Controlled PV•of the independent certification ■Properties for System Design 14.450KW Grid Tied institute TOV Rheinland. Maximum System Voltage v,,, [VJ 1000pEC)l7000(UL) Pv module clasaiflcation CIaSs11 Photovoltaic System Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 C/TYPE 2 p 'See data Sheet or,rea,to,mrihermtminuo. Max.Design Load,Push/Pull' [lbs/ft'] 75(3600Pa)/75(3600Pal) Permitted Module Temperature -40'Fupto+185'F $ 'APT testcMloiaorls according to hKIT562804-t:2075,method A1-i500v.96 n) ---- _--Max.Teat Load,Push/PUIP PbSM2] U3(5400 Pa)/113(5400 Pa) on Continuous Duty (-40°C up to+85'q 6970 INDIAN NECK LN, PECONIC,NY 11958 See Installation Manual $ Rev Description Date ■Qualifications and Certificates A INITIAL DESIGN 4/2/2024 Quality CAnaMled PV- TUV Rheinland; + IEC 612152016: OPPORTUNITY PATRICIA LOW RV IEC 61730:2016. The Ideal solution for: This data sheet complies C E o �n PROJECT# 9866 �1e with DIN EN 5038 �0. d -� d. Rooftop arrays on +ww-rw mu DATE DRAWN 4/2/2024 DRAWN BY ER residential buildings �.,� . Ocells pursues minimizing paper output in consideration of the global environment. SHEET# PV-12.0 ,cote mnalle6on msnlxvon must W hawed Coma.o.,lac Ul wince for runnerIW-ti--approved I,rclenetlon o1-prod... �cerpl'c TITLE nenwhe G CL�S Amer'...Inc.WO SP-1-Cdh Drive.Suite 14 0,I-CA 92616,USA-•194914a 599a'1-1,hde�rq 1,1ft=115.com WU www.00ells.rom v MODULE SPEC ENPHASE. IQ8 and IQ8+ Microinverters Commonly used module pairings' W 235-350 235-440 To meet compatibility.PV modules must be within maximum input DC voltage and maximum module t listed below. Module compatibility - Module compatibility can be checked at ggps.//enphase.com/installers/microinverters/calculator MPPT voltage range V 27-37 27-45 THESE DRAWINGS ARE SUBJECT TO Operating range V 16-48 W-58 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS Minimum/Maxinwmstart voltage V 22/48 22/58 _ EXPRESSLY FORBIDDEN WITHOUT PRIOR Maximum input DC voltage V 50 80 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Maximum moduie 1 A 20 Current Overvoftage class DC port — II Renewable r, DC port backfeed current mA 0 Engineering PV array configuration — 1•1 ungrounded array:no additional DC side protection required:AC side protection requires maximum 20 A per branch circuit. CURRENT RENEWABLES ENGINEERING INC. Peak output power VA 245 300 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 Maximum continuous output power VA 240 290 PHONE:(951)-405-1733 WWW.CRENG.CO Nominal grid voltage(L-L) V 240.split-phase(L-0.180- IQ8 and IQ8+ Microinverters Easy to CONTRACTOR INFO M;n;mum and Maximum grid roltage' V 211-284 • Lightweight and compact with plug- Maximum continuous output current A 1.0 121 Our newest I08 Microinverters are the industry's first micr rid-formi software-defined 09 ng• and-play connectors Nominal frequency Hz 60 microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brake of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range Hz a7 68 rE application-specific integrated circuit(ASIC),which enables the mioroinverter to operate in between components AC short-circuit fault current Over 2 C SYS 9 grid-tied or off-grid modes.This chip is bulk using advanced 55-nm technology with high-speed • Faster installation with simple two-wire Arms digital logic and has superfast response times to changing loads and grid events,alleviating cabling three cycles constraints On battery sizing for home energy systems. Maximum units per 20 A(L-L)branch - 16 13 circuit' ELEMENT ENERGY LLC. High productivity and reliability 7470 SOUND AVENUE,MATTTTUCK, Total harmonic distortion % c5 NEW YORK,11952 Produce power even when the grid is i _ PH:(631)779 7993 Enphase down' Overvoftage class AC port IR • _ I services@e2sys.com More than one million cumulative hours AC port backfeed current MA 30 Licence-ME-52689 of testing (MASTER ELECTRICIAN) g Power factor setting - 1.0 Licence-HI-67461 Class it double-insulated enclosure --- Grid-tied power factor(edlustable) - 0.85 Wading...0.85 lagging (SUFFOLK HOME IMPROVEMENT) Part of the Enphase Energy System, IQ8 Series Microinverters redefine Optimized for the latest high-powered 977 I08 Series Microinverters integrate with the reliability standards with more than one PV modules Peak efficiency 96 - --- - Solar Individual 10 Battery.10 Gateway.and the million cumulative hours of power-on CEC weighted efficiency % 97 Enphase App monitoring and analysis testing,enabling an industry-leading 25 Permit Package software. limited warranty of up to 25 years. Microgrid-forming Nighttime power consumption mW 23 Compliant with the latest advanced grid support- PATRICIA LOWRY Ambient temperature range -WC to 80'C(-40'F to 140'F) Remote automatic updates for the ------ - - - — - - - - latestgridrequirements Relative humidity range 4%to100%(condensing) 14.450KW Grid Tied s Configurable to support a wide range DC connector type - MCa _ _ - Photovoltaic System of grid profiles Dimensions(H•W a 212 min(8.3 in)•175 min(6.9 IN•30.2 min 0.2 in) Connect PV modules quickly and easily IQ8 Set ies Microinverters are UL Listed Meet CA Rule 21(UL 1741-SA)and IEEE' Weight 1.08 kg(2.38lbs) 6970 I N DIAN NECK LN, to I08 Series Microinverters using the as PV rapid shutdown equipment and 1547:2018(UL 1741-SB 3"Ed.) PECON IC,NY 11958 included Q-DCC-2 adapter cable with Conform with various regulations,when Cooling Natural oorwection-no fans plug-and-play MC4 connectors. installed according to the manufacturer's NOTE, Approved for wet locations Yes Rev Description Date Instructions. • 108 Microinverters cannot be mixed with pollution degree PD3 - A INITIAL DESIGN 4/2/2024 previous generations of Enphase Microinverters (107Series,106 series,and so on)in the same Enclosure Class II double-insulated.corrosion-resistant polymeric enclosure system. IO Gateway is required to change the detauh Environmental category/UV exposure rating NEMA Type 5/Outdoor LDRAVMBY PATRICIALOWRY •Meets UL 1741 only when installed with 10 System controller 2. grid profile at the time of installation to meet 3866 '•IQ8 and IQ8-support split-phase,240 V installations only. local Authority Having Jurisdiction(AHJ) requirements. 4I2I2024 m W lmf -W DC/AC,tH E.R 0 20Z3 Enphase Energy.Allrightsr.sarv.d.Enphaca,theaand CC lgos,l0.arW cwtain other martr listdt (y Nomino vonapa ranv.an oe astandea tbvona wmewnrxaa.w W ino utinty.httgs://enphase.com/trdmark-usage-guidelines are trademarks of Entities.Energy.Inc.in the US and other countries.Data sub;ect to change. 1085P-12A-0.5H-00207-2.0-EN-US-2023-10-13 (3lMinedr^.r ,aNw to w:+l nauw«r+nn ro d.n.»n,.,wmew o!miodm«t..s p.,b..scn i�rw�«s. IQBSP-12A-DSH-00207-2.0-EN-US-2023-10-13 PV-12.1 INVERTER SPEC 0000000ll Enphase IQ Combiner 4/4C Data Sheet MODEL NUMBER Enphase Networking IQ Combiner 4(X-IQ•AM1-240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C1220+/-0.5%)and consumption monitoring(+/-2.59%).Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C(X-IQ AM1.240-4C) IQ Combiner 4C with Enphase IQ Gateway printed Circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-Ml-06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enphase The Enphase IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the lQ Battery and lQ System Controller and to deflect heat. THESE DRAWINGS ARE SUBJECT TO ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) COPYRIGHT PROTECTION BY US LAW IQ Gateway and Integrated LTE-Ml Cell - _.. _.------___. _. .----_. . - REPRODUCTION IN ANY FORM IS Q Combiner 4/4 C Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05 with 5-year Sprint data plan for EXPRESSLY FORBIDDEN WITHOUT PRIOR modem (included only with IQ Combiner 4C) COMMS-CELLMODEM-Ml-06 Ensemble sites WRITTEN APPROVAL FROM CURRENT CELLMODEM-Mt-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan RENEWABLES ENGINEERING INC. X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-M1-06-AT-05 4G based LTE-Ml cellular modem with 5-year AT&T dataplan X-IQ-AM1-240-4C Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. into a single enclosure and streamlines IQ BRK-1OA-2-240V Circuit breaker,2 pole,I OA,Eaton OR21 0 Current BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 L� microinverters and storage installations by BRK-20A-2P240V Circuit breaker,2 pole,20A,Eaton BR220 "'@l1eW3EJ��'S BRK 15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support (� providing a consistent,pre-wired solution for BRK-20A-2P-24OV-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support Engineering residential applications. It offers up to four EPLC-01 Power line carrier(communication bridge pair),quantity-one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C CURRENT RENEWABLES 2-pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) ENGINEERING INC. ENPHASE 1760 CHICAGO AVE SUITE busbar assembly. XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C J-13 RIVERSIDE CA 92507 PHONE:(951(d05-1733 X-10-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. WWW.CRENG.CO ELECTRICAL SPECIFICATIONS CONTRACTOR INFO Smart Rating Continuous duty Includes IQ Gateway for communication and control System voltage 120./240 VAC,60 Hz • Includes Enphase Mobile Connect cellular modem Eaton BR series bulbar rating 125 A (CELLMODEM-M1-06-SP-05),included only with IQ Max continuous current rating 65 A dam Combiner 4C Max.continuous current rating(input from PV/storage) 64A CG-'SYS Includes solar shield to match Enphase IQ Battery Max fuse/circuit rating(output) 90 A aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation IDS)breakers only(not included) Flexible networking Supports W i-Fi, Max total branch circuit breaker rating(input) BOA of distributed generation,95A with IQ Gateway breaker included ELEMENT ENERGY LLC. Ethernet,or cellular 7470 SOUND AVENUE,MATTfTUCK, Envoy breaker 10A or 15A rating GE/Siemens/Eaton included NEW YORK,11952 Optional AC receptacle available for PLC bridge -----:------ -- - -- ---- PH:(631)779 7993 Production metering CT 200 A solid core pre-installed and wired to IQ Gateway • Provides production metering and consumption services@e2sys.com #4 monitoring Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers Licence-ME-52689 y. MECHANICAL DATA (MASTER ELECTRICIAN) _ -------._ _-- _— Licence-HI-67461 Simple Dimensions(WxHx6) 37.5 x 49.5 x 16.8 cm(14.75'x 19.5'x 6.63') Height is 21 06•(53.5 cm)with mounting brackets (SUFFOLK HOME IMPROVEMENT) Weight 7.5 kg(16.5 Ibs) Centered mounting brackets support single Ambient temperature range -40°C to+461 C(-40°to 115°F) Solar Individual stud mounting Cooling Natural convection,plus heat shield Permit Package Supports bottom,back and side conduit entry Up to four 2-pole branch circuits for 240 VAC Enclosure environmental rating Outdoor,NRTL-certified,NEMAtype 3R,polycarbonate construction plug-in breakers(not included) Wire sizes 20 A to 50 A breaker inputs 14to4 AWG copper conductors PATRICIAL OWRY • 60 A breaker branch input,4 to 1/0 AWG copper conductors X-I10-AM1-240 4C _` 80A total PV Or Storage branch Circuits Main lug combined output.10 to 2/0 AWG copper conductors 1 Neutral and ground:14 to 1/0 copper conductors 14.450KW Grid Tied Always follow local code requirements for conductor sizing. Photovoltaic System t Reliable Attitude To 2000 meters(6,560 feet) ` INTERNET CONNECTION OPTIONS Durable NRTL-certifiedNEMA type 3R enclosure 69701NDIANNECKLN, Five-year limited warranty Integrated Wi-Fi 802.11b/g/n PECONIC,NY 11958 Two years labor reimbursement program coverage Cellular CELLMODEM-MI-06-SP-05,CELLMODEM MI-06-AT-05(4G based LTE-M1 cellular modem).Note that an Enphase included for both the IQ Combiner SKU's Mobile Connect cellular modem Is required for all Ensemble installations. Rev Description Date UL listed Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) A INITIAL DESIGN 4/2/2024 COMPLIANCE Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class 8,ICES 003 U Production metering:ANSI C12.20 accuracy class 0.5(PV production) OPPORTUNITY PATRICIA LOW RY _ Consumption metering:accuracy class 2.5 PROJECT# 8866 X�Q AMI 240 4 Compliance,IQ Gateway UL 60601-1/CANCSA 22 2 No 61010 1 DATE DRAWN 4/2/2024 I:EM � ENPHASE. n ENPHASE, DRAWN BY ER To learn more about Enphase offerings,visit enohase.com �./ To learn more about Enphase offerings,visit com �-/ SHEET# PV-12 2 2022 Fnphase Fnergy All rights reserved Fnphase,the Fnphase logo,IQ Combiner 4/4C,and other names are trademarks of TITLE Enphase Energy,Inc Data subject to change.02-14-2022 COMBINER SPEC IRONRIDGE XR Rails' Family XR Rail° Family The XR Railc'`Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Over their lifetime. solar panels experience countless mac` � REPRODUCTION IN ANY FORM IS extreme weather events. Not just the worst storms in years. i EXPRESSLY FORBIDDEN WITHOUT PRIOR ears. High winds capable of WRITTEN APPROVAL FROM CURRENT but the worst storms in 40 Y 9 p i RENEWABLES ENGINEERING INC. ripping panels from a roof,and snowfalls weighing — enough to buckle a panel frame. Current XR Rails are the structural backbone Renewab{es preventing these results.They resist uplift. " , XRtO XR100 XR1000 protect against buckling d safe) y"""�`� Engineering p g uc g an y �+ XR10 is a sleek.low-profile mounting XRt00 is a residential and commercial XR1000 is a heavyweight among and efficiently transfer loads into the rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails It's built to handle building structure.Their superior no snow It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 CURRENT RENEWABLES spanning capability requires fewer dam' while remaining light and economical. maximizing spans up to 10 feet feet for commercial applications ENGINEERING INC. 1760 CHICAGO AVE SUITE roof attachments, reducin the 6'spanning capability 10'spanning capability 12'spanning capability J-13,RIVERSIDE CA 92507 9 number of roof penetrations Moderate load capability Heavy load capability Extreme load capability PHONE (951)-405-1733 WWW CRENG CO • Clear 8 black anodized finish Clear&black anodized finish Clear anodized finish and the amount of Internal splices available Internal splices available Internal splices available CONTRACTOR INFO installation time. Rail Selection ` E The table below was prepared in compliance with applicable engineering codes and standards.*Values are E2 SYSu ROM based on the followingcriteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. ELEMENT ENERGY LLC. Span , 7470 SOUND AVENUE,MATTrrUCK, Rail NEW YORK,11952 AM ® P vi(631)779 s.co - • - 993 services@e2sys.com Licence-ME-52689 Force-Stabilizing Curve 90 (MASTER ELECTRICIAN) Sloped roofs generate both vertical and lateral 120 Licence-HI-67461 forces on mounting rails which Can Cause them to _ NUt12 (SUFFOLK HOME IMPROVEMENT) bend and twist The curved shape of XR Rails° y is specially designed to Increase strength in both 140 XR1� XR1000 In directions while resisting the twisting This unique Solar Individual feature ensures greater security during extreme 160 Permit Package weather and a longer system lifetime. 90 120 PATRICIA LOWRY 20 140 14.45OKW Grid Tied 160 Photovoltaic System 30 90 6970INDIAN NECK LN, 160 ; PECONIC,NY 11958 Rev Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials INITIAL DESIGN A INITIAL Date 4/2/2024 XR Rails°are IronRldge°offers All XR Railsx are made of 6000-series 40 compatible with a range of tilt leg aluminum alloy.then protected with an 160 FlashFoot"and options for flat anodized finish Anodizing prevents surface A other pitched roof roof mounting and structural corrosion,while also providing 80 160 OPPORTUNITY PATRICIA LOWRY attachments applications. a more attractive appearance. — 120 16U PROJECT# 8866 DATE DRAWN 4/2/2024 'Table is meant to be a simplified span chart for conveying general.rail capabilities.Use approved certification letters for actual design guidance. DRAWN BY E R SHEET# PV-12 3 arsion Visd ,��� TITLE r RAIL SPEC ZZA, I RON RI DGE QuickMount' Adaptive, Rafter-Friendly Installation THESE DRAWINGS ARE SUBJECT TO e Respect our Roof Deserves COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS When integrating with a home,solar attachments EXPRESSLY FORBIDDEN WITHOUT PRIOR • • //.��,. WRITTEN APPROVAL FROM CURRENT must be dependable for the lifetime of the rooftop. _ • y\�/ RENEWABLES ENGINEERING INC Due to recent innovations,many asphalt shingles - v� have bonded courses.A mount that protects without the need to pry shingles can really speed things up. Current i Halo UttraGrip4(HUG")is here to respect the roof. • `y ` Renewac. Its Halo is a cast-aluminum barrier that encases the — 0 _ � _ �� s � Engineering UltraGrip,our industrial-grade,foam-and-mastic seal.This allows HUG to accelerate the installation CURRENT RENEWABLES •• ENGINEERING INC. process and provide the utmost in waterproofing Hit the rafter?Good • 1760 CHICAGO AVE SUITE protection.Give your roof a HUG." • J-13.RIVERSIDE CA 92507 When you •a rafter.you • on • - to the left or • • -than 3 screws miss the rafter. PHONE.(9511405-1733 Only 2••Structural Screws are needed. rafter is found. •and final screw. secure six screws to deck mountWWW.CRENG CO W CONTRACTORINFO P Multi-Tiered Waberproofmg --- - - HUG'utilizes a mufti-tiered stack of componentsofing provide protection revolutionary Halo c Trusted Strength 8r Less Hassle waterproofing protection The Halo cast- akxninum.raised-perimeter foundation 1+> Structural capacities HUG,were reviewe d in z °S Irrounds the UI1raGnp base-a foam- ura ca p es o ��w�0 mastic seal combination that many load directions,with racking rail running u water intrusion by adhering _ ng with the shingle surface. cross-slope or up-slope in relation to roof pitch. i ELEMENT ENERGY LLC. Halo UltraGrip'"is part For further details, see the HUG certification 7470 SOUND AVENUE,MATTITUCK, the QuiekMount' NEW YORK,11952 letters for attaching t0 rafters and decking. PH:(631)779 7993 product line. _. services@e2sys.com _ - IronRidge designed the HUG, in combination Licence-ME-52689 UltraGri Seal Technol with the RD Structural Screw to streamline (MASTER ELECTRICIAN) P� Licence-HI-67461 HUG UhraGnp utilizes state-of i• Installs,Which means the following: (SUFFOLK HOME IMPROVEMENT) art seal design that uses a uniq i foam-and-mastic combination.T foam-backed adhesive provides No prying shingles Solar Individual entirely new flashing system that ' No roof nail interference Permit Package conforms and adheres to every 25-Year Warranty g and cranny of composition shing Product guaranteed tree No pilot holes necessary tilling gaps and shingle step-downs - of impairing defects No sealant(in most cases) PATRICIA LO W RY (up to 118•in height) .r • No butyl shims needed f 14.450KW Grid Tied 7Attachment Structural Water Seal UL 2703 Photovoltaic System LoadingDesign 6970 INDIAN NECK LN, •' PECONIC,NY 11958 Rev Description Date Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to A INITIAL DESIGN 4/2/2024 Mount HUG"to the root rafters,the root deck,or both with our custom-engineered HUG has been and certified for the UL 441 Section UL 2703 mechanical RD(rafter-or-deck)Structural Screw.The RD tested and rated to compliance with 27"Rain Test"and and bonding Triple Rated&Certified Structural Screw anchors HUG to the roof OPPORTUNITY PATRICIA LOW RY to Respect the Roof- support 1004(Ibs)of the International TAS 100(A)-95 requirements. See with an EPDM sealing washer,completing PROJECT# 8966 s UL 2703,441(27) the stack of waterproofing barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual Intertek TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. DATE DRAWN aaizo2a DRAWN BY E R SHEET# PV-12 4 a m 2023 ` TITLE ! ATTACHMENT SPEC 28357 Industrial Blvd. Hayward,CA 94545 28357 Industrial Blvd Hayward.CA 94545 R O N R I D G E 1-800-227-9523 I R O N R I D G E 1-800-227-9523 IronRidge.com IronRidge.com Attn:Corey Geiger,COO: IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following Date:September 7',2021 Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1 The Flush Mount System is designed as a Risk Category 11 structure as defined by ASCE 7-16 Table 1.5-1. 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B(for Risk Category II)and applicable state&local This letter addresses the structural performance and code compliance of IronRidge s Flush Mount System. The county/city amendments to the IBC No special wind topographic features are included and both topographic contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(Kr.)and wind ground elevation factor(Ke)are taken as 1 0 THESE DRAW NGS ARE SUBJECT TO proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape COPYRIGHT PROTECTION BY US LAW 3 Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig REPRODUCTION OR S orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails 7.2-1 and PRE FORBIDDEN WITHOUT PRIOR applicable state&local county/city amendments to the IBC If the local jurisdiction specified snow load is in the WRITTEN APPROVAL FROM CURRENT and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof format of a flat roof snow, it shall first be converted to a ground snow following the local building code/ RENEWABLES ENGINEERING INC attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables.No special snow conditions are considered that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding,retention,or ponding snow.No rain-on-snow surcharge load is components are shown in Exhibit EX-0015. considered.The span tables do not apply to buildings which are Intentionally kept below freezing,kept just Current above freezing,or unheated. w R�ne The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: Rene -l r C listed below for the load conditions and configurations tabulated in the attached span tables (a)For ground snow no greater than 42psf:SS 5 2.Og for Site Class A.B.C,&D • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:SS<1.0g for Site Class A.B,C,&D. CURRENT RENEWABLES ENGINEERING INC. • 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:Ss<_1.5g for Site Class A.B,C,&D. 1760 CHICAGO AVE SUITE • 2020 Building Code of New York State(BCNYS-2020. PHO . Published in November 2019) RIVERSIDE 92507 PHONE:(951)-005-1-1733 • 2015 Aluminum Design Manual(ADM-2D15) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in WWW CRENG CO which the zones share the same External Pressure Coefficients(GCp).Roof zones comprising each group along • Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays with each roof zone's size and location are depicted in Figures 2 and 3 below each span table CONTRACTOR INFO The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point.shall the respective loads and configurations listed,covering wind exposure categories B.C.&D,roof zones provided in be the lesser of the following two conditions.40%of the allowable span provided for the respective load ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8`to 45°.The tabulated spans are applicable when the &configuration condition from the span tables,or 36'. a 0 following conditions are met: 7 Allowable span length in the charts may be multiplied by a factor of 1 08 if the rails are continuous over E P SYSA a minimum of three spans. 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment fastener). & No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: ELEMENT ENERGY LLc. 7470 SOUND AVENUE,MATTITUCK, a) XR Bonded Splice cannot be installed in the Center 1/3 of interior spans,or the outer 2/3 of end spans. NEW YORK,11952 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated b) BOSS Splice can be installed at any location within a span. PH (631)779 7993 om based on 2 rails stems.and conservative) deemed acceptable for 3 rails stems services-ME-5. 89 Y YY Licence-ME-52689 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded If (MASTER ELECTRICIAN) 3. The underlying roof slope.measured between the roof surface and horizontal plane,is 8°to 45°. such conditions are encountered contact support@ironrdge com. Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 4. The mean roof height.defined as the average of the roof eave height and the roof ridge height measured Solar from grade,does not exceed 30 feet Pack Permit Individual Package 5 A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not PATRICIA LOWRY exceed 10". 14.450KW Grid Tied 6 Module length and area shall not exceed the maximum values listed on the respective span tables Photovoltaic System 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush 6970 INDIAN NECK LN, Mount Installation Manual and other applicable standards for the general roof construction practice PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 ©2021 IronRidge,Inc. NY Flush Mount System Certification Letter 1 s 2021 IronRidge Inc NY Flush Mount System Certification Letter-2 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 4/22024 DRAWN BY FR SHEET# PV-12.5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd Hayward.CA 94545 Hayward.CA 94545 RON RI DGE 1-800-ge.cor23 I RON RI DGE 1-800-ge.co 23 IronRidge.com IronRidge.com 10. Systems using CAMO module clamps shall be installed with the following guidance: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67 5",CAMO consideration of the structural adequacy of the chosen roof attachments.PV modules,or the underlying roof supporting clamps shall not be installed in regions that experience ground snow loads of 70psf and greater.Such THESE DRAWINGS ARE SUBJECT TO scenarios are shown by asterisks in the applicable span tables. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the COPYRIGHT PROTECTION BY US LAW. aforementioned system components in regards to the applied or resultant loads of an chosen array configuration. REPRODUCTION IN ANY FORM IS b) CAMO will function within a module's design load ratings.Be sure the specific module being used with y p g PP y y g EXPRESSLY FORBIDDEN WITHOUT PRIOR CAMO meets the dimensional requirements shown in the figure below and that the module selected is WRITTEN APPROVAL FROM CURRENT _ _ . suitable for the environmental conditions of a particular project. ' RENEWABLES ENGINEERING INC 2 0 21 0 9 0 7 Sincerely, P�� tar, xtj �O • • MocuieGlass7Ceets ;;. 1 Aiii Current IF w - 15:45: 16 -' - Renewables _ Engineering Frame ROFES'to�tl'� —0 7 0 0 CURRENT RENEWABLES X=1.2 Z2� — ENGINEERING INC. Y=IS 40 mm 1760 CHICAGO AVE SUITE Gang Xuan,PE PHONE s51)-405-1733507 Y 1 Senior Structural Engineer WWW CRENG CO F—x T CONTRACTOR INFO Figure f CAMO Module Frame Dimensional Requirements Span values for Exposed and Edge module conditions,as defined below,are included in the attached span Id 13 tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; Cz SYS (2)The span value determined by site wind speed and ground snow load.Additionally,irrespective of the lesser AU span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTrrUCK. NEW YORK,11952 PH:(631) 7993 1. Exposed Module conditions: services@e2sys.com e2sys.cos.com Licence-ME-52689 (MASTER ELECTRICIAN) A module is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free Licence-HI-67461 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave ridge, rake,or (SUFFOLK HOME IMPROVEMENT) hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from its free edge to any other adjacent array or panel is greater than 4 feet. Solar Individual The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed Permit Package Modules PATRICIA LOWRY 2. Edge Module conditions: 14.450KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave,ridge,rake,or hip)is less than 2 times the height of the array(2h2) 6970 INDIAN NECK LN, where h2 is measured from the roof surface to the top surface of the module. PECONIC,NY 11958 The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Rev Dept— Date Additionally, if the roof edge is the eave or ridge.only the rail nearest to that roof edge shall be considered A INITIAL DESIGN 412/2024 for this span adjustment OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 C 2021 IronRidge Inc NY Flush Mount System Certification Letter-3 C 2021 IronRidge.Inc NY Flush Mount System Certification Letter 4 DATE DRAWN 4/2/2024 DRAWN BY ER SHEET# PV-12 6 TITLE CERTIFICATION Page 1 of 2 Current 06/24/2024 Renewables ELEMENT ENERGY LLC. Engineering Subject: Structural Certification for Installation of Residential Solar Job: Lowry Residence Project Address: 6970 Indian Neck Lane, Peconic; NY, 11958 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of ELEMENT ENERGY LLC.. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 OF NEW Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com 106793 A F Np� Signed on:06/24/2024 1760 Chicaqo Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewablesenq.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x6 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 16 degrees and has a max beam span of 11.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x6 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 32 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. I Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewablesengxom ROOF MOUNT SOLAR PERMIT PACKAGE CODE INFORMATION THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC jL ��0_V NEW PATRICIA LO W RY POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: ��pe�RI A. 2020 INTERNATIONAL BUILDING CODE 14.450 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 INTERNATIONAL RESIDENTIAL CODE rcif 2020 INTERNATIONAL EXISTING BUILDING CODE 2020 INTERNATIONAL FIRE CODES 106793 6970 I N DIAN NECK LN PECON IC NY 11958 2020 INTERNATIONAL MECHANICAL CODE o� _FESSIONP�� > > 2020 INTERNATIONAL PLUMBING CODE 2020 INTERNATIONAL ENERGY CONSERVATION CODE Exp:9/30/2025 2017 NATIONAL ELECTRICAL CODE STAMPED 06/24/2024 BUILDINGINFORMATION THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 2 STORY HOUSE SINGLE FAMILY RESIDENCE ACCOUNT NO. 9641541206 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U AHJ : TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC ROOF:COMP SHINGLE APN:1000086000700000000 METER NO: 98300265 PV SYSTEM SUMMARY: WIND SPEED 128 Current STRUCTURAL NOTES : SNOW LOAD 25 Renewables SYSTEM SIZE(DC) STC: 425 x 34= 14.450KW DC 1. THESE PLANS ARE STAMPED FOR PTC: 395.25 x 34= 13.4385KW DC STRUCTURAL CODE COMPLIANCE OF THE EXPOSURE CATEGORY D Engineering SYSTEM SIZE (AC) 10,880KW AC @ 240V ROOF FRAMING SUPPORTING THE PROPOSED CURRENT RENEWABLES MODULES (34) HANWHA QCELLS Q.TRON BLK M-G2+425W PV INSTALLATION ONLY. ENGINEERING INC. 2. THESE PLANS ARE NOT STAMPED FOR 176U C J-13,RIVERSIO EC SUITE VERSIDE CA 92507 WATER LEAKAGE. PHONE CRESNG o0,733 MICRO-INVERTERS ENPHASE: IQ8MC-72-M-INT 3. PV MODULES, RACKING, AND ATTACHMENT AERIAL VIEW VICINITY VIEW CONTRACTORINFO MICRO-INVERTERS QTY 34 COMPONENTS MUST FOLLOW MANUFACTURER TILT 16°, 32' GUIDELINES AND REQUIREMENTS. AZIMUTH 235°, 145' 4. PLEASE SEE THE ACCOMPANYING �s STRUCTURAL CALCULATIONS REPORT FOR ROOF COMP SHINGLE RAFTER/TRUSS SIZE 2"X6"RAFTER @ 24"O.C. ADDITIONAL INFORMATION.5. PRIOR TO COMMENCEMENT OF WORK, THE CZ SYS ATTACHMENT TYPE a IRONRIDGE HALO ULTRA GRIP WITH IRONRIDGE SOLAR INSTALLER SHALL VERIFY THE ROOF ELEMENT ENERGY LLC. XR-100 FRAMING INFO BEFORE INSTALLATION AND 7470 SOUND AVENUE,MATTITUCK, MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH 200 AMPS MAIN NOTIFY THE E.O.R. IF THERE IS ANY PH:(631)779 7993 NEW YORK,11952 BREAKER ON TOP FED INCONSISTENCY BETWEEN SITE VERIFICATION services@e2sys.com INTERCONNECTION LINE SIDE TAP AND FOLLOWING: 2x6 RAFTERS @ 24" OC Licence-ME-52689 (MASTER ELECTRICIAN) OCPD RATING 60 AMPS SPACING WITH MAX UNSUPPORTED SPAN Licence-HI-67461 UTILITY LONG ISLAND POWER AUTHORITY EQUAL OR LESS THAN 14 FT. (SUFFOLK HOME IMPROVEMENT) GENERAL NOTES: Solar Individual .► Permit Package 1 LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 3, PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED SHEET INDEX PATRICIA LOWRY 4, ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5 ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT VVITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 14.450KW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7, THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9, IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE 6970 INDIAN NECK LN, 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE PV-3.0 STRUCTURAL PECONIC,NY 11958 MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" PV-4.0 ELECTRICAL 3LD 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS Rev Description Date 12, MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" PV-5.0 ELECTRICAL SLD A INITIAL DESIGN 4/2/2024 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM A 1 UPDATED DESIGN 6/25/2024 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH690,35. PV-7.0 ELECTRICAL PHOTOS OPPORTUNITY �ATRICIALDWRV 15 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PV-8.O S I G NAG E PROJECT# IAT 16 INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 17 ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.1 PLACARD DATE DRAWN 6/25/2024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY E R 18 CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/81,ABOVE ROOF SURFACE. PV-9.0 M I CROI NVERTER CHART 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE SHEET# PV I D ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH PV-10.0 SAFETY PLAN TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0 SAFETY PLAN 20, MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: PV-1 2.0+ SPEC. SHEETS NOTR324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON ENLARGED VIEW LEGEND SEPARATE ROOF PLANES, �P��O NEW yO FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. UM UTILITY METER `� oO�Rt A. Z 5'F AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. I N D I A N NECK L N FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC MINIMUM MSP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOFF EDGE EDGE TO RIDGE r SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLASUPPORTING FIRE FIGHT SHALL BE I N D I A N NECK L N �c AC DISCONNECT OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS 64;j O 106793 WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR FESSIONP� MECHANICAL EQUIPMENT. ' C❑ COMBINER (E) UTILITY METER Exp:9/30/2025 R324.6.2 SETBACK AT RIDGE: � c FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 1 ! — -- MODULE STAMPED 06/24/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A i ' I---- PROPERTY LINE HORIZONTAL RIDGE. .�✓ ` `` THESE DRAWINGS ARE SUBJECT 70 ROOF OBSTRUCTIONS COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 i �� M / MSP UM REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A t 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A EXPRESSLY FORBIDDEN WITHOUT PRIOR I / .`t I I ROOF ACCESS POINT WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. t` AC RENEWABLES ENGINEERING INC R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS I TRENCH CONDUIT AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE I Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE Renewates PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. A -PATHWAY ON STREET ! i (N) FUSED AC DISCONNECT Engineering OR DRIVEWAY SIDE OF ROOF ' B -FIRE ACCESS POINT I ; (E) MAIN SERVICE PANEL CURRENT RENEWABLES ENGINEERING INC. WlErEA - I PHONE E (951)O AVE SUITE 36"ACCESS PATHWAYS ' PHONEIV 95SI 405-733DE CA 507 VWNN.CRENG.CO CV � 18"ACCESS PATHWAYS i CONTRACTOR INFO 00 NOTES: 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED �, ! ON ACTUAL SITE CONDITION ANDgin MEASUREMENTS. ' CZ SYS0 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS 863'-1" I . INCORPORATED INTO THE 2017 NEC AND UL i (N) 1" PVC UNDER GROUND STANDARD 1741. ! I � CONDUIT @ 18" BELOW 3. EXISTING ROOF VENT SHOULD NOT BE cfl ELEMENT ENERGY LLC. GRADE�-150' (TRENCHED) 7470 SOUND AVENUE,MATTITUCK, COVERED. ; � NEW YORK,11952 � PH:(631)779 7993 i Licence-ME-52689 (MASTER Licence-LHI-67 61 •w � I (SUFFOLK HOME IMPROVEMENT) FENCE Solar Individual Permit Package 0 > PATRICIA LOWRY ROOF OBSTRUCTION SHED ROOF ACCESS POINT 14.450KW Grid Tied / Photovoltaic System rn 6970 INDIAN NECK LN, (N) COMBINER PECONIC,NY 11958 `at Rev Description Date t A INITIAL DESIGN 4/2/2024 '• DRIVEWAY ROOF LINE Al UPDATED DESIGN 6/25/2024 doPROPERTY LINE --! , OPPORTUNITY PATRICIA LOWRY PROJECT# 9866 1 DATE DRAWN 6/25/2024 ' 31'-10" ROOF ACCESS POINT DRAWN BY E R SIT E P LA N ! SHEET# PV-2 0 1 57'-6" TITLE ®_ f_ SCALE: 1/128" = 1'-0" - 82, --1— SITE PLAN ARRAY AREA LEGEND EAVETO ROOF ROOF TOTAL #OF RIDGE ARRAY AREA EA AREA AREA ROOF ROOF TYPE AZIMUTH MODULES DIMENSION (Sq.Ft.) (q ) COVERED BY COVERED BY p��,0 NEW y0 (Ft.) ARRAY(°/) ARRAY(%) UM UTILITY METER ���0��t A �'40 �� #1 COMP SHINGLE 235 7 11.4 147.14 2701 5A5 26.46 #2 COMP SHINGLE 1 145 27 14.10 567.54 2701 21.01 MSP MAIN SERVICE PANEL r I i W AC DISCONNECT 106793 N DIAN NECK LN c❑ COMBINER FESSIONP�� Exp:9/30/2025 (E) UTILITY METER MODULE STAMPED 06/24/2024 ` THESE DRAWINGS ARE SUBJECT TO ROOF OBSTRUCTION A COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS `�`. EXPRESSLY FORBIDDEN WITHOUT PRIOR TRENCH CONDUIT WRITTEN APPROVAL FROM CURRENT Msp UM RENEWABLES ENGINEERING INC. I t � AC ! Current enewables -- - Engineering (N) FUSED AC DISCONNECT CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE (E) MAIN SERVICE PANEL WWWNNV (s51.CRENG.CC 1733 CONTRACTORINFO la ® np ECSYS6 (N) 1"PVC UNDER GROUND ELEMENT ENERGY LLC. CONDUIT @ 18" BELOW 7470 SOUND AVENUE,MATTITUCK, GRADE--150' (TRENCHED) NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PATRICIA LOWRY j 14.450KW Grid Tied Photovoltaic System ROOF#1 6970 INDIAN NECK LN, PECONIC,NY 11958 -- - Rev Desanption Date (N) COMBINER A INITIAL DESIGN 4l2/2024 A 1 UPDATED DESIGN 6/25/2024 (N)#34 HANWHA QCELLS Q.TRON BLK s M-G2+425W OPPORTUNITY I PATRICIA LOWRY PROJECT# 8866 ROOF#2 DATE DRAWN 612512024 ROOF PLAN SHEET#DRAWN BY ER 2 PV-21 TITLE SCALE: 1132' = 1'-0. ROOF PLAN ROOF ROOF ROOFING FRAMING FRAMING OC PENETRATION MAX NO TILT TYPE TYPE SIZE SPACING PATTERN MAX ATTACHMENT TYPE PENETRATION NEwy SPACING OVERHANG �~p O�Rt A. f4 0,P� �o o� ROOF 1 16 COMP SHINGLE IRONRIDGE HALO ULTRA GRIP RAFTER 2"X6" 24" STAGGERED 72" 24" r W ROOF 2 32 COMP SHINGLE IRONRIDGE HALO ULTRA GRIP RAFTER 2"X6" 24" STAGGERED 72" 106793 FESSIO�P�� Exp:9/30/2025 STAMPED 06/24/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC Current Renewables Engineering HANWHA QCELLS Q.TRON BLK M G2+425W CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE IRONRIDGE XR-100 J-13,RIVERSIDE CA 92507 PHONE(951)-405-1733 TABLE PENETRATION WW W.CRENG.CO GUIDE FOR INSTALL CONTRACTORINFO 4„ (E)COMP SHINGLE TWO OR MORE ROWS OF PANELS 77: IRONRIDGE HALO ULTRA GRIP E2SYS I I I I I I I I I I I I I I I I I I I I T TRAFrER X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING I I I I I I I I I I ( I I I I I I ELEMENT ENERGY ATTI 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com 6"RAFTER@ 24"O.C. I I I I I I I I I I I I I I I I I I Licence-ME-52689 ENLARGED VIEW I I I I I I I I I I I I I I I I I I (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) IRONRIDGE XR-100 STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE HALO ULTRA GRIP Permit Package HANWHA QCELLS Q.TRON BLK M-G2+425W ONE ROW OF PANELS PATRICIA LOWRY SEE ENLARGED VIEW 14.450KW Grid Tied I I I I I I I I I I I Photovoltaic System (E)2"X6" RAFTER@ 24" O.0 \ I I I I I I I I I I I I I 6970 INDIAN NECK LN, PECONIC,NY 11958 FULLY STAGGERED STACKED/STAGGERED Rev Description Date ATTACHMENT DETAILS (E)coMP SHINGLE - Al UPDATED DESIGN INITIAL DESIGN 5/25/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 6/25/2024 DRAWN BY ER SHEET# I PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING OF NEW MAX. CONTINUOUS OUTPUT 1.33A @ 240V ACCOUNT NO. : 9641541206 �P��oE MANS y0,p 45.22 X 1.25 = 56.53AMPS 60A FUSES-OK CO METER NO: 98300265 C �'V OL * 0 �ci r D A n w m 099128 2 ZN�OA CTRIGP� ��C9 (E)UTILITY METER �OFESSIONP� (N)ENPHASE (ERVICE PANEL STAMPED 06/25/2024 MAIN SERVICE PANEL COMBINER BOX MODEL 1PH,120240V 60HZ NO#X-IQ-AM1-240-5/5C (E)200A 2P MAIN 2-#12 AWG,SRE COPPER GROUND HN /� BREAKER 1-#6 AWG.BARE COPPER GROUND J�CT'//(�_� (TOP FED) CELL WIRE LESS /� (12) IQBMC-72-M-INT — MODEM COMMS - - v THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. MICROINVERTERS REPRODUCTION IN ANY FORM IS Ip GATEWAY /�— EXPRESSLY FORBIDDEN WITHOUT PRIOR BRANCH525W ��� WRITTEN APPROVAL FROM CURRENT '2 HANWHA QCEQ.TRON N i - RENEWABLES ENGINEERING INC. BLK M-G2+ t {N)15A:� _ (N)60A FUSED /� AC DISCONNECT (t 1) IQBMC-72-M-INT — /.. SQUARE D D322NR6 ��� —(N)LINESIDE TAP VIA UL MICROINVERTERS (N)20Am WITH 60 A FUSES, '�1\` LISTED CONNECTOR Current �' KNIFEBLADE, Renewab�es BRANCH-2 (t'1I20A/n LOCKABLE.NEMA 3R, 11 HANW M-G2+425WTRON N ULLISTED Engineering BLK M-G2+425W — ——— (M20�T J �1 �� TO UTILITY 4� OVERHEAD - --- -------- --- --- ----------———————— ———— (t t) IQBMC-72-M-INT -- q-f! 1 FEED MICROINVERTERS ————— I CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE BRANCH-3 3-#4 AWG.THWN 3-#6 AWG,THWN I J-13,RIVERSIDE CA 92507 t 1 HANWFiA QCELLSQTRONJN __ ____J 1-#8 EGC,THWN 1-#8 EGC,THWN I ———— PHONE:(951)-405-1733 BLK M-G2+425W , IN 1"PVC UNDER IN 3/4"OR LARGER PVC L——————— WWW CRENG CO GROUND CONDUIT @ 18" CONDUIT . . BELOW GRADE-150' CONTRACTOR INFO ECTRODE (TRENCHED) CONDUCTOR#6 B GROUNDING LARE COPPER MODULE MANUFACTURER QCELLS C Z SYS6 MODULE MODEL Q.TRON BLK M-G2+42SW ELEMENT ENERGY LLC. MODULE(W) 42S 7470 SOUND AVENUE,MATTITUCK, MODULE PTC(W) 399.00 NEW YORK,11952 PH:(631)779 7993 MODULE Isc(A) 13.66 services@e2sys.com MODULE Voc(V) 39.03 Licence-ME-52689 (MASTER ELECTRICIAN) MODULE Imp(A) 2.98 Licence-HI-67461 MODULE Vmp IV) 32.74 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUITAND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A PATRICIA LOWRY WIRE SCHEDULE STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 14.450KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT Photovoltaic System # EQUIPMENT WIRE LOCATION QTY. WIRE AMPACITY RATING (°C) FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 6970 INDIAN NECK LN, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY PECONIC,NY 11958 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.66 0.96 1 28.80 17.08 Rev Description Date A INITIAL DESIGN 4/2/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 15.96 0.96 1 28.80 19.95 Ai UPDATED DESIGN 612512024 3 AC COMBINER TO AC DISCONNECT TRENCH 3 4 95 90, 45.22 0.96 1 91.20 56.53 OPPORTUNITY PATRICIA LOWRY 4 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 45.22 0.96 1 72.00 56.53 PROJECT# 6866DATE DRAWN 6/25/2024 DRAWN BY ER SHEET# PV-4 0 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING OF NEW MAX. CONTINUOUS OUTPUT 1.33A @ 240V Q�� E N/ Y ACCOUNT NO. : 9641541206 MA * oo �co� 45.22 X 1.25 = 56.53AMPS 60A FUSES-OK METER NO: 98300265 D w m w 099128 Z ZN�O A C TR I O' �40 SSIONP�' (E)UTILITY METER (E)200A RATED STAMPED 06/25/2024 (N)ENPHASE MAIN SERVICE PANEL 1 PH,120240V 60HZ COMBINER BOX MODEL • NO#X-IQ-AM1-240-5/5C (E)20DA/2P MAIN 2-#12 AWG,SKU:Q-I2-RAW-300 THHN BREAKER 1-#8 AM,BARE COPPER GROUND CELL (TOP FED) THESE DRAWINGS ARE SUBJECT TO 12 IQBMC-72-M-INT — MODEM WRE LESS COPYRIGHT PROTECTION BY US LAW ( ) COMMS MICROINVERTERS REPRODUCTION IN ANY FORM IS IQ GATEWAY EXPRESSLY FORBIDDEN WITHOUT PRIOR BRANCH-1 WRITTEN APPROVAL FROM CURRENT 12 HANWHA QCELLSQ.TRON N m RENEWABLES ENGINEERING INC. BLK M-G2+425W (N)15A:51 m (N)60A FUSED 1 AC DISCONNECT �r\• (11) IQBMC-7RTERT — (MUNESIDE TAP VIA UL Current MICROINVERTERS (Mzo�m SQUARE D D322NRB �Y WITH 60A FUSES, •�i LISTED CONNECTOR KNIFEBLADE, • Renewat� BRANCH-2 LOCKABLE,NEMA 3R, es 11 HANWHA QCELLSWTRON N UL LISTED /` Engineering OVERHEAD BLK M-G2+425 (N)2oA.m /"1 �b •�• UTILITY OVERHEAD (11) I08MC-72-M-INT FEED CURRENT RENEWABLES MICROINVERTERS ENGINEERING INC. 1760 CHICAGO AVE SUITE BRANCH-3 11 HANWHA QCELLSQ.TRON N 3-#4 AWG,THWN 3-#6 AWG,THWN J-13,RIVERSIDE CA 92507 BLK M-G2+425W 1-#8 EGC,THWN 1-#8 EGC,THWN PHONE.(951)-405-1733 IN 1"PVC UNDER IN 3/4"OR LARGER PVC WWW.CRENG.CO GROUND CONDUIT @ 18" CONDUIT BELOW GRADE-150' = CONTRACTOR INFO (TRENCHED) (E)GROUNDING ELECTRODE CONDUCTOR#6 BARE COPPER a a nt MODULE MANUFACTURER QCELLS C Z SYSA. MODULE MODEL Q•TRON BLK M-G 2+425 W ELEMENT ENERGY MODULE(W) 425 7470 SOUND AV NUE,MATTITUCK, MODULE PTC(W) 399.00 NEW YORK.11952PH:(631)779 7993 MODULE Isc(A) 13.66 services@e2sys.com MODULE Voc(V) 39.03 Licence- (MASTER ELECTRICIAN) MODULE Imp(A) 2.98 Licence-HI-67461 MODULE Vmp IV) 32.74 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A PATRICIA LOWRY WIRE SCHEDULE 14.450KW Grid Tied STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM Photovoltaic System RACEWAY AWG CURRENT FACTOR FOR ADJUSTED CURRENT CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION# EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO 6970 INDIAN NECK LN, QTY. AMPACITY RATING ('C) FACTOR PECONIC,NY 11958 SIZE 310.15(B)(16) CONDUCTORS IN 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS RACEWAY 310.15(B)(3)(a) IN RACEWAY Rev Description I Date A INITIAL DESIGN 1 4/2/2024 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90' 13.66 0.96 1 28.80 17.08 Al UPDATED DESIGN 6/252024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90, 15.96 0.96 1 28.80 19.95 OPPORTUNITY PATRICIA LOWRY 3 AC COMBINER TO AC DISCONNECT TRENCH 3 4 95 90° 45.22 0.96 1 91.20 56.53 PROJECT# 8966 DATE DRAWN 6/25/2024 4 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 45.22 0.96 1 72.00 56.53 DRAWN BY E R SHEET# PV-5.0 TITLE ELECTRICAL SLID MATERIAL LIST ��°FNEwy �P ooE'nnaN�,� ELECTRICAL EQUIPMENTS w � W QTY. PART TYPE PART NUMBER DESCRIPTION 099128 z 34 MODULE Q.TRON BLK M-G2+ 425W QCELLS Q.TRON BILK M-G2+ 425W N�o CTR1111 34 MICROINVERTER IQ8MC-72-M-INT ENPHASE IQ8MC-72-M-INT ARO Ss1oNP� 1 FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED STAMPED 06/25/2024 1 COMBINER X-IQ-AM1-240-5/5C ENPHASE COMBINER BOX X-IQ-AM1-240-5/C 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewab#es Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO BREAKER / FUSES CONTRACTOR INFO QTY. PART TYPE PART NUMBER DESCRIPTION 1 FUSES 60A FUSES GENERAL 60A FUSES 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) CL-'" SYSLJ ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) RACKING (SUFFOLK HOME IMPROVEMENT) QN• PART TYPE PART NUMBER DESCRIPTION Solar Individual 40 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK Permit Package 26 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 PATRICIA LOWRY 82 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK 28 CLAMPS & GROUNDING UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK 14.450KW Grid Tied 7 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE Photovoltaic System FLASHFOOT2, BLACK 129 ATTACHMENTS FF2-02-B2 6970INDIAN NECK LN,PECONIC, NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 A UPDATED DESIGN 6/25/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 6l25/2024 DRAWN BY E.R SHEET tt PV-6 0 TL E BOM EXISTING SERVICE PANEL PHOTOS OF NEW r D W m w 099128 2 Z��OA 4 CTRIGP� V �OFESs►ONP STAMPED 06/25/2024 THESE DRAWINGS ARE SUBJECT TO ..4. COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. f^ CURRENT RENEWABLES ENGINEERING INC. - 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO CONTRACTORINFO EZSYS� ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) AMR AI L&ftL_ Solar Individual ko" - Permit Package PATRICIA LOWRY h 14.450KW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, --- PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 A UPDATED DESIGN 6/25/2024 OPPORTUNITY PATRIOA LOWRY PROJECT# 8866 DATE DRAWN 6/25/2024 DRAWN BY ER SHEET# PV-70 TITLE ELECTRICAL PHOTOS OF NEIq/ co 0 CG PHOTOVOLTAIC I\ /I r D LU V m 099128 'EQUIPPED WITH RAPID SHUTDOWN 2N�OA C7RIGP\• `U'Z 690.12 RO SS1ONP� STAMPED 06/25/2024 WITH RAPID SHUTDOWN THESE DRAWINGS ARE SUBJECT TO COPYRIGHT BY TURN RAPID DISCONNECT REPRODUCTION NEANYOFO FORM SHUTDOWN SWITCH TO ' OUTPUT EXPRESSLYI77ENFORBI LFROMDEN THOUTPRIOR 45.22 AMPS WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. THE "OFF" POSITION TO AC AC NORMALOPERATING VOLTAGE1 VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current AND REDUCE SHOCK "WARNING" Renewable HAZARD IN THE ARRAY PM DUAL POWER • Engineering 690.56(C)(1)(B) SECOND SOURCE PHOTO- • ' IC SYSTEM CURRENT RENEWABLES ENGINEERING INC. OUTPUTRATED AC . 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 ' NORMAL OPERATING • ' 1VOLTS PHONE (951)-405-1733 WW✓V.CRENG CO CONTRACTOR INFO 690.54 OPTIONAL SOLAR LOAD CENTER n ARRAY oa EZSYS° ELEMENT ENERGY LLC. J�B 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 OUTPUT • • (MASTER ELECTRICIAN) INVERTERLicence-HI-67461 • • REL• ' THIS (SUFFOLK HOME IMPROVEMENT) NEC 690.31(G)(3)&(4),CRC R324.7 • "WA _ Solar Individual (UNLESS BUSBAR IS FULLY RATED) Permit Package 705.12(D)(2) PHOTOVOLTAIC • SOURCE PATRICIA LOWRY EVERY 1U ON CONDUIT AND ENCLOSURES 14.450KW Grid Tied Photovoltaic System NOTES. 6970INDIAN NECK LN, 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS PECONIC,NY 11958 SHOWN HEREON. Rev Description Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 4/2/2024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A 1 UPDATED DESIGN 6/2 512 0 2 4 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE OPPORTUNITY PATRICIA LOWRY WORK. PROJECT# 8866 C. AERIAL FONT. DATE DRAWN 6/25/2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY E.R THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-8.0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. OF NEW �POQEMAN� O G1 t- D W m w 099128 Z ZN�OA CTRICP� CJ SSIONP� � STAMPED 06125/2024 I C O REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewabies Engineering CURRENT RENEWABLES ENGINEERING INC. PV ARRAY 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE(951)405-1733 VNWN/CRENG.CC z CONTRACTOR INFO LU ]C V Q aor MAIN SERVICE PANEL z Cc SYS6 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 COMBINER AC DISCONNECT PH:(631)779 7993 services@e2sys.com UTILITY METER Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PATRICIA LOWRY PANEL IS AC DISCONNECT PER NEC690.17 14.450KW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, PECONIC, NY 11958 Rev Descnption Date A INITIAL DESIGN 4/2/2024 A 1 UPDATED DESIGN 6/25/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 6/25/2024 DRAWN BY E.R SHEET# PV-8.1 TITLE PLACARD MICROINVERTER CHART 1 -10 1 1 -20 21 -30 31 -40 41 -50 51 -60 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current - .enewakfes Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHI CAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO CONTRACTOR INFO 5 all M EZSYS ELEMENT ENERGY LLC. 6 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied 8 Photovoltaic System 6970 INDIAN NECK LN, PECONIC, NY 11958 Rev Description Date 9 A INITIAL DESIGN 4/2/2024 A 1 UPDATED DESIGN 6/25/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 6,'25/2024 DRAWN BY ER 10 SHEET# PV-9 0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INS I RUCTION& THESE DRAWINGS ARE SUBJECT TO ❑c COMBINER COPYRIGHT PROTECTION BY US LAW. 1 USE SYMBOLS IN KEY TO MARK UP THIS SHEET. REPRODUCTION IN ANY FORM ISEXPRESSLY FORBIDDEN WITHOUT PRIOR 2 SAFETY PLAN MUST BE MARKED BEFORE JOB AC DISCONNECT WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN RENEWABLES ENGINEERING INC. 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE MSP MAIN SERVICE PANEL & MAKE NOTES ON THE JHA SHEET UTILITY METER let Current IN CASE OF EMERGENCY Renewables NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC OP PERMANENT ANCHOR Engineering CURRENT RENEWABLES NAME: ENGINEERING INC. ADDRESS. O TEMPORARY ANCHOR 1760 RIVERSCHICAGIDE CAVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 INSTALLER LADDER WWW CRENG CO SAFETY COACH CONTACT INFORMATION IL CONTRACTOR INFO NAME: STUB-OUT ADDRESS: ® SKYLIGHT 1221n* ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE NO LADDER ACCESS (STEEP GRADE CZSYS�( SAFETY PLAN AND SIGN INDICATING THAT THEY ARE OR GROUND LEVEL OBSTRUCTIONS) AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. ❑ RESTRICTED ACCESS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NAME SIGNATURE TRENCH NEW YORK,11952 PH:(631)779 7993 GAS GAS SHUT OFF services@e2sys.com Licence-ME-52689 Hzo WATER SHUT OFF (MASS nRceLHI-67461 O (SUFFOLK HOME IMPROVEMENT) � SERVICE DROP O POWER LINES Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, PECONIC,IN 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 DATE: TIME: A UPDATED DESIGN 6/25/2024 OPPORTUNITY I PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 6/25/2024 DRAWN BY ER SHEET# PV-100 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. • The safety of the Client and the Public must be maintained at all • The site supervisor shall forecast the weather conditions at the • Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,Wind,rain,etc.) discretion(location is annotated below).If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure.Extensions le ladders laced on work zone through the use of barriers and/or si na e,as • The site supervisor will utilized a portable wind meter COPYRIGHT PROTECTION R IS LAW. style P 9 9 9 P P permission,location of suitable restroom facilities with REPRODUCTION IN ANY FORM IS uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. • Restroom facilities will be(circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. • Elevated work involving the moving or maneuvering of solar • If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind Current 1.1 climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure Ren@W able s leaned against a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor • Additional notes: • Crew leader responsible for communication With the client: Engineering Name: Mobile Equipment • Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment;operators must Yes,No): Heat Related Illness Prevention Phone: CURRENT RENEWABLES maintain a certification on their person for the equipment bein • Employees shall have access to potable drinking water that is ENGINEERING INC. P9P 9 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13 RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): • All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE (951)-405-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: www c- co P 1 9 P j PP q b 9 9 • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift.Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to • Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the • Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: a IV rel • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees C c SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: u • A site-specific plan for fall prevention and protection is required • Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete;a fall rescue plan must be outlined and • Crew member(name/title): New employees must be acclimatized.New employees will be of what happen and when. 7470 SOUND AVENUE,MATTITUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK.11952 • First-person-Up(FPU)must install their anchor and connect • Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift.Employees must take Licence-ME-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-HI-67461 • Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and • Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed • Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an PATRICIA LOWRY electrically safe condition(de-energized)unless approval has • If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 14.45OKW Grid Tied • Service drops and overhead electrical hazards will be • If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: indentified and protected from contact,as neccessa . water(location/address): Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 6970 INDIAN NECK LN, PECONIC,NY 11958 Define the Hazard: Method/steps to prevent incident: Rev Descnplion I Date A INITIAL DESIGN 1 4/2/2024 A 1 UPDATED DESIGN 6/25/2024 OPPORTUNITY I PATRIOA LDWRY PROJECT# 8866 DATE DRAWN 6/25/2024 DRAWN BY ER SHEET# PV-11.0 TITLE SAFETY PLAN QXRON BLK In In O-TRON BLK M-G2+ SERIES IMWEn ■Mechanical Specification M-G2+ SERIES Q�G ep"S A Format < 67c":n 44.6�r>'16 in;incl,d n5 frame) (1722�t:m�1134mm•30mm1 Weight 4671bs(21.2 kg) Front Cover 013 in(32 mm',thermally pre-shessed glass 4v asr w"n arMi-reflection technology 405-425 Wp 1108 Cells Back Cover Co-V oLe film 21.8% Maximum Module Efficiency Frame Buck anodised aluminum Cell 6 x IS morrocrystaftine GANTUM NEC,solar half cells TO Junction box 2.09-3.g8in.12fr2.36m•0,59-0.71 r. �' THESE DRAWINGS ARE SUBJECT A ;53-1D1mm 32-60mm s 15-lBmm),Protection class 1%7,Wtth ttypass diodes _ .b �'� 4J "" ' COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS Cable 4rrm'Sola1 cable.(+I a68.9,C750rnm.(-I268.9in 11750mm EXPRESSLY FORBIDDEN WITHOUT PRIOR Connector S,*_"i Mc-1a68 Caul.-tea_ear 1TAsrrs.�. WRITTEN APPROVAL FROM CURRENT MODEL QT-RON BLK M-132+ - - RENEWABLES ENGINEERING INC. ■Electrical Characteristics POWER CLASS 4" 4W 41S 420 425 � Current M.N.MJV DER.=ORMANCE AT STANDARD'EST COND-IONS,STC°(POWER-O-ERANCE-5W!-0 W;; )1"q 405 4 ", '���ewaa��S o.aNTvr High performance Qcells N-type Power ° 0 415 420 425 i EG Short Circuit Current' ?A': 1333 1341 1349 13.58 '3.66 Engineering NED solar cells E F Open Circuit Voltage' Vim_ 37.91 38.19 3847 3875 3903 'J=;i Ice-not with o bmized module la -* current at MPP I„. ";A; 12.69 12.76 12,83 12.9I 1298 t7gy p yoJ- CURRENT RENEWABLES ---cy up to 21.8`L Voltage at MPP V_ Y 31.93 3213 32.34 32.54 32.74 ENGINEERING INC. Efficiency 11 %j 2207 >_21 0 r213 221.5 221,8 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 25 A reliable investment MINIMJN PcK=ORVANCE AT NORMAL OaERArING CONDI 0NS.N MCTs VVWW CRENG CO Inclus,ve25-yea-product warranty and25-year lineal, PWOUatMPP Pr lull 3061 309.9 313.7 317.5 32. CONTRACTOR INFO NarnatMp Je-forma-ce warra'lly'. E Short Circuit Current I� A; 1074 10.81 10.87 10,94 11.00 � E Open Circuit Voltage Vx Y 35.96 3623 36.50 3677 37.04 c f Current at MPP 0.66 30.87 1010 10.15 1.46 =; 0-21 Enduring high performance Votage at MPP V_ ;vj 30.66 30.87 3t.07 31.26 3Ta6 - �l 'Mea5�erie^t to-erances P,,,,,t3%;;.;V,.f 5%at STC.1000w/m=,25t 2'C.AM 1.5 accordng Ic IEC 60904-3-2800 WJm-'-NMOT.spectrum AM!.5 .� V Longderm yield Security with Anti LeTID Technology.Anti PH) �■� Techno+ogy' a ON ,iyot-Spot P*otect "-'-'•'°"^ pDh�iE PERFORMANCE AT LOW IRRADIANCE C 2 S YSA u L acts; a+ At cas.985%of nominal power Extreme weather rating dunngfis Year Thweafre,rr x ELEMENT ENERGY I d - -- - - 0.33%Je9rada wr year At "-' 11 :oche.ml--rr Wf�rame.cerlifiedfor i leas!95.53%ofnommalpoWer � mF--)----- 747050 NEW YORK,11 52TTITUCK, W to toigh caw(5400 Pa)and wind 11(5400 Pa). -nai ems Ap to 2 years of i z � nomnal power up to zs years PH:(631)779 7993 c 5 „ services@e2sys.com LL AN Cara vwthel measuremem Tolerances.FW Warp tN strl Licence-ME-52689 <g accordance wtn it*wararrty i (MASTER ELECTRICIAN) Innovative all-weather technology c M o ter of the O e9s ales p �(- p e s m >< orgarisetionor -Ir give as ,- .00 .pp .oqo Licence-HI-67461 C5 ODtimal yields,whatever th eflt e weather with excell low-light EAR' county y PRA,mncrw m (SUFFOLK HOME IMPROVEMENT) and temperature behaviour. 5tangart'lens M 41xra,lee•o:T�s w cq-pmre-..:n r,e ryocal padre penomarec uron ru.R-aew-ce:a,ercns� k. '«q�es G" 'win uwecA/n2r12'!ce6very?bif =gmVensw III,STC mnd.�tlons(25'C 1000W,m') u+ Solar Individual n The most thorough testing I PERArUREcOEFFICIEN`113 Permit Package �w{ programme in the industry Temperature Coefficient of lx o r. K +0.04 Temperature Coefficient of Val 5 a/Ki -024 Temperature Coefficient of Ps°, v J%fIC -0.30 Nominal Module Operating Temperature NMOT ('F) 109f 5.4 :,ice__ s the first solar module ata-.`acturer to pass the (4313°q PATRICIA LOW RY most comprehensive quality programme in the industry.The new-QuardyControlledPV-&the;ndependentCerthfication ■Properties for System Design 14.4501NV Grid Tied irlsiitute TUV Rheinland. Maximum System Voltage VM IV" 1000(IEQ 1000(UL) PV module classification Class tl o Photovoltaic System Maximum Series Fuse Rating iA DC; 20 Fire Rating based on ANSI/UL 61730 C 1 TYPE 2 4 'Seedat�vreet­eartu<tumrer�,Tor,rrallu�. Max_Design Load,Push/Pull' llbsrlt'] 75(3600Pa;i75(3600Pa) Permitted Module Temperature -40°FUD'.o+185°F a'APT test uondiiI ad"Eo IECITS62804-12015,reaoCA',-1500V 96h) - on Continuous Duty (-40'C up to+85'Q 6970 INDIAN NECK LN, Max.Test Load,Push/Pull' [lbsifNj 113(5400Pa)/113(5400oa! _ 3See Installation Manua: a PECONIC,NY 11958 Rev Description Date ■Qualifications and Certificates A INITIAL DESIGN 412/2024 A UPDATED DESIGN 6/25/2024 OualNy Conttollec Pv Tuv Rheinland; - $ IEC 6127520%: O E � E OPPORTUNITY PATRICIA LOWRY IEC 61ata:,%. �N- -- - Theidealsolutionfor: 2=1 l� This caw sheet copies � PROJECT# 8866 c,,,.a�w With DIN EN 50380. t W I� - yk'. DATE DRAWN 6/25I2024 Rooftop arrays on 1 O:�` 91 residential buildings' �, DRAWN BY E.R ocells pursues minimizing paper output in consideration of the global environment. SHEET# PV-12.0 Norr InStA�ulbn rnnucuore must ee ronowed.comas-recn-sr.•ce c f.nner imo.:.e r.,.pprovM nsrmlprbn of In s-d„a. I' TITLE Mnnwry C CE.S A,-,,,In AM Sp-' nter Ce Er .suhe I­ 92618 JSA I TF1-1949 748 So 96 i L-11 W-muiry4 MM Igcelk Q`�I I WEB www.gcMscom v MODULE SPEC ENPHASE IQBMC Microinverter INPUT DATA r r' Commonly used module pairings W 260-460 Module compatibility _ To meet compatibility,PV modules must be within the following max.input DC voltage and max.module I,,. Module compatibility can be checked at nttps://enphase_com/'atstayers/micromverters/calcLlatpr. MPPT voltage range V 25-45 Operating range V 18-58 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Min./Max.start voltage v 22/58 REPRODUCTION IN ANY FORM IS Max.Input DC voltage v 60 EXPRESSLY FORBIDDEN WITHOUT PRIOR P 9 WRITTEN APPROVAL FROM CURRENT Max.continuous operating DC current A 14 RENEWABLES ENGINEERING INC. Max.input DC short-circuit current A 25 Max.module 1. A 20 Current Overvoltage class DC port - II Renew dlA@S DC port backfsed current mA 0 Engineering PV array configuration - Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit 'VAC IOBMC-72-1,14S @204VAC CURRENT RENEWABLES Peak output power VA 330 315 ENGINEERING INC. Q 8 M C Microinverter 1760 RIVERSIDE AVE SUITE Easy to install Max.continuous output power VA 320 310 J-13,RIVERSIDE CA 92507 PHONE'(951)405-1733 Lightweight and compact with plug-and-play Nominal grid voltage(L-U V 240.split-phase(L-U,180" 208.single-phase(L-U.120" WWW.CRENG.CO Our newest IQ8 Series Microinverters are the industry'sfirst microgrid-forming*,software-defined microinverters with split-phase power conversion capability to convert DC power to connectors Min./Max.grid voltage 2 V 211-264 183-229 CONTRACTOR INFO AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC)between application-specific integrated circuit(ASIC),which enables the microinverter to operate in components Max continuous output Current A 1.33 4s grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire Nominal frequency Hz 60 digital logic and has superfast response times to changing loads and grid events,alleviating cabling Extended frequency range Hz 47-68 constraints on battery sizing for home energy systems. AC short circuit fault current over three High productivity and reliability Arms 2.7C a 1M cycles Enphase Produces power even when the grid Is down* Max.units per 20 A(L-L)branch circuit' - 12 10 C S YS O More than one million cumulative hours of Total harmonic distortion % <5 ELEMENT ENERGY LLC. ! testing 7470 SOUND AVENUE,MATTITUCK, Class 11 double-insulated enclosure Overvoltage class AC port - 111 NEW YORK,11952 Part of the Enphase Energy System- I08 Series Microinverters redefine Optimized for the latest high-powered PV AC port backfead current mA 18 PH:(631)779 7993 modules services@e2sys.com I08 Series Microinverters integrate with reliability standards with more than one Power factor setting - 1.0 Licence-ME-52689 the IQ Battery,IQ Gateway,and the million cumulative hours of power-on (MASTER ELECTRICIAN) Enphase App monitoring and analysis testing,enabling an industry-leading Microgrid-forming Grid-tied power factor(adjustable) - 0.85 leading...0.85lagging Licence-HI-67461 software. limited warranty of up to 25 years. • Complies with the latest advanced grid Peak efficiency % 97.4 97.2 (SUFFOLK HOME IMPROVEMENT) support CEC weighted efficiency % 97.0 96.5 ax Remote automatic updates for the latest grid Nighttime power consumption mW 33 25 Solar Individual requirements1 MECHANICAL DATA UNITS Configurable to support a wide range of grid Permit Package profiles Ambient temperature range -40'C to 65'C(-40°F to 149°F) Meets CA Rule 21(UL 1741-SA)and Relative humidity range 4%to 100%(condensing) PATRICIA LOW RY Connect PV modules quickly and easily I08 Series Microinverters are UL Listed IEEE 1547:2018(UL 1741-SB) to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and DC connector type Staubli MC4 integrated MC4 connectors. conforms with various regulations when NOTE: Dimensions(H x W-D);Weight 212 mm(8.3")•175 mm(6.9")x 30.2 mm(1.2');1.1 kg(2.43lbs) 14.450 KW Grid Tied installed according to the manufacturer's Photovoltaic System Instructions. IQ8 Microinverters cannot be mixec together with Cooling Natural convection-no fans Y previous generations of Enphase—oinverters (107 Series.IO6 Series.and so on)In the same Approved for wet locations;Pollution degree Yes;PD3 system. Enclosure Class 11double-Insulated.corrosion-resistant polymeric enclosure 6970 INDIAN NECK LN, 10 Microinverters snip with default settings that PECONIC, NY 11958 meet North America's IEEE 1547 interconnection Environ.category;UV exposure rating NEMA Type 6;o jtdoor standard requirements.Region-spedfic Rev Description Date adjustments maybe requested by an Authority r Having Jurisdiction(AHJ)or utility representative. A INITIAL DESIGN 4W2024 'Meets UL 1741 only when installed with IQ System Controller 2 or 3. An 10 Gateway Is required to make these changes CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class 6,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01. du•ing ins tallation. Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017.NEC 2020,and NEC 2023 section 690.12 and A 1 UPDATED DESIGN 6/25/2024 C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. 2024 Enphase Energy.All rights reserved.Enphase.the a and CC logos.IQ and certain other marks fisted at (1)No enforced 7C/AC ratio. OPPORTUNITY PATRICIA LOWRY Mt .//enphase.com/trademark-usggegidelines are trademarks of Enphase Energy,Inc.in the US.and other countries. (2;Nominal voltage range can be extended beyond norninal if required by the utility Data subject to change. 108MC-MC4-DSH-00049-4.0-EN-US-2024-02.09 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MC-MC4-DSH-00049-4.0-EN-M-2024-02-09 PROJECT# 8866 DATE DRAWN 6/2 512 02 4 DRAWN BY E.R SHEET# PV-12 1 TITLE MICROINVERTER SPEC ENPHASE IQ Combiner 5/5C MODEL _ 10 Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV production IQ Combiner 5(X-I0-AM1-240-5) metering(ANSIC12.20±0.5%),consumption monitoring(±2.5%),and 10 Battery monitoring(±2.5%). Includes a silver solar shield to deflect heat. IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production IQ Combiner SC(X-IQ-AM1-240-5C) metering(ANSI C12.20±0.5%).consumption monitoring(±2.5%)and IQ Battery monitoring(�.5%). Includes Enphase Mobile Connect cellular modem(CELLMODEM-MI-06-SP-05)'.Includes a silver solar shield to deflect heat. WHAT'S IN THE BOX i THESE DRAWINGS ARE SUBJECT TO {� IQ Gateway is the platform for total energy management for comprehensive,remote maintenance,and COPYRIGHT PROTECTION BY US LAW. IQ Gateway printed circuit board REPRODUCTION IN ANY FORM IS management of the Enphase Energy System EXPRESSLY FORBIDDEN WITHOUT PRIOR Bulbar 80 A bulbar with support for 1•IQ Gateway breaker and 4.20 A breaker for installing IQ Series WRITTEN APPROVAL FROM CURRENT Microinverters and IQ Battery 5P RENEWABLES ENGINEERING INC. IQ Gateway breaker Circuit breaker.2-pole,10 A/15 A Production CT Pre-wired revenue-grade solid-core CT.accurate up to--0.5% Current X-I0-AM11-240-5 Consumption CT Two consumption metering clamp CTs,shipped with the box,accurate up to±2.5% Renew abt e S X-I0-AMl-240-5C IQ Battery CT One battery metering clamp CT,shipped with the box,accurate up to±2.5% Engineering CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Q C o m b i n e r 5/5 C Enphase Mobile Connect(only With IQ Combiner 5C) 4G-based LTE-M1 cellular modem(CELLMODEM-Mt-O6-SP-05)with a 5-year T-Mobile data plan CURRENT RENEWABLES ENGINEERING INC. Accessories kit Spare control headers for the COMMS-KIT-02 board 1760 CHICAGO AVE SUITE Smart J-13,RIVERSIDE CA 92507 The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and ACCESSORIES r REPLACEMENT PARTS 1 INCLUDED, ORDER PHONE.(951)-405-1733 streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent. Includes IQ Gateway for WNWV.CRENG.CO pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control communication and control CELLMODEM-Mt-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan CONTRACTOR INFO communication and is compatible with IQ System Controller 3/3G and IQ Battery 513. Includes Enphase Mobile Connect CELLMODEM-Mt-06-AT-05 4G-1pased LTE-M7 cellular modem with a 5-year AT&T data plan (CELLMODEM-MI-06-SP-05),only The IQ Combiner 5/5C,IQ Series Microinverters.10 System Controller 3/3G,and IQ Battery with IQ Combiner 5C Supports Eaton BR2XX,Siemens Q2XX and GE/ABB THOL21XX Series circuit breakers(XX represents 5P provide a complete grid-agnostic Enphase Energy System. Circuit breakers(off-the-shelf) 10.15.20,30,40.50,or 60).Also supports Eaton BR220B.BR230B,and BR240B circuit breakers • Supports flexible networking:Wi-Fi, compatible with the hold-down kit. Ethernet,or cellular .._ QIrCUlt breakers((provided Enphase) BRK-10A-2-240V,BRK-15A-2-240V,BRK-20A-2P-240V,BRK-15A-2P-240V-B,and BRK-20A-2P IN 13- -" Provides production metering p by p 240V-B(more details in the-Accessories"section) V D (revenue grade)and consumption C 2 S 1 SU monitoring XA-SOLARSHIELD-ES Replacement solar shield for 10 Combiner 5/5C XA-ENV2-PCBA-5 10 Gateway replacement printed circuit board(PCB)for 10 Combiner 5/5C ELEMENT ENERGY LLC. Easy to install 7470 SOUND AVENUE,MATHTUCK, It X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws) NEW YORK,11952 IQ Series Microinverters IQ System Controller 3/3G Mounts to one stud with centered PH:(631)779 7993 The high-powered smart grid-ready IQ Series Provides microgrid interconnection brackets XA-COMMS2-PCBA-5 Replacement COMMS-KIT-02 printed circuit board(PCB)for 10 Combiner 5/5C services@e2sys.com Microinverters(IQ6.IQ7,and I08 Series)simplify device(MID)functionality by Licence-ME-52689 • Supports bottom,back,and side SPECIFICATIONS the installation process. automatically detecting grid failures and conduit entries (MASTER ELECTRICIAN) seamlessly transitioning the home energy Rating 80 A Licence-HI-67461 system from grid power to backup power. Supports up to four 2-pole branch (SUFFOLK HOME IMPROVEMENT) circuits for 240 VAC plug-in breakers System voltage and frequency 120/240 VAC,60 Hz (not included) Busbar rating 125 A ' 80 A total PV branch circuits Solar Individual - Fault current rating 10kAIC Permit Package Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Maximum continuous current rating(input from PV/storage) 64 A fu Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR,Siemens Q.or GE/ABB THQL Series distributed generation(DG)breakers PATRICIA LO W RY ----- T" Reliable only(not included) IQ Battery 5P IQ Load Controller Durable NRTL-certified NEMA type 3R Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IQ Gateway breaker included 14.450KW Grid Tied Fully integrated AC battery system.Includes six Helps prioritize essential appliances enclosure IQ Gateway breaker 10 A or15 A rating GE/Siemens/Eaton included Photovoltaic System field-replaceable IQ8D-BAT Microinverters. during a grid outage to optimize energy 5-year limited warranty consumption and prolong battery life. Production metering CT 200 A solid core pre-installed and wired to 10 Gateway • 2-year labor reimbursement program 69701NDIAN NECK LN, coverage included for both the Consumption monitoring CT(CT-200-CLAMP) A pair of 200 A clamp-style current transformers Is Included with the box P ECON I C, NY 11958 IQ Combiner SKUs' 10 Battery metering CT 200 A clamp-style current transformer for IQ Battery metering,included with the box UL1741 Listed KOM Rev L Description Date C A INITIAL DESIGN 412/2024 A.1 UPDATED DESIGN 6/25/2024 LISTED 1. A plug-ard-play incustral-grade cell modem for systems of up to 50 mioroinverters.Available In the United States.Canaca.Mexico.Puerto Rico.and the US Virgin Islands.where there is adequate 5-year limited cellular service in the installation area. OPPORTUNITY PATRICIA LOWRY warranty PROJECT# sass 'For country-specific warranty information,see the https://enphase.com/installers/resources/warranty page. DATE DRAWN 6/25/2024 ®2024 Enphase Energy.All rights reserved Enphase.the a and CC logos.IQ and certain other marks listed at DRAWN BY E.R os:i/enohase.com/t�ademart-oleos-cu define,are trademarks of Enphase Energy.Inc.In the U.S.and other countries. SHEET# PV-12.2 Data srb)ect to charge. IOC-5-5C-DSH-00007-3.0-EN-US-2024-C3-01 IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-0t TITLE COMBINER SPEC /lr IRONRIDGE XR Rail" Family XR Rail's Family The XR Rail@ Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads,while minimizing material costs. Depending on your location,there is an XR Rails to match. ��_ THESE DRAWINGS ARE SUBJECT TO Over their lifetime, solar panels experience Countless COPYRIGHT PROTECTION BY US LAW. P P REPRODUCTION IN ANY FORM IS extreme weather events. Not just the worst storms in years, EXPRESSLY FORBIDDEN WITHOUT PRIOR but the worst storms in 40 years. High winds capable of f` WRITTEN APPROVAL FROM CURRENTRENEWABLES ENGINEERING INC ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. Current XR Rails@ are the structural backbone Renewables preventing these results.They resist uplift, XR10 XR100 XR1000 protect against buckling and safely .� Engineering .. XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR100D is a heavyweight among and efficiently transfer loads into the rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle building structure.Their superior a no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 CURRENT RENEWABLES while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. ENGINEERING INC. spanning capability requires fewer _ 1760 CHICAGO AVE SUITE roof attachments, reducing the 6'spanning capability 10'spanning capability 12'spanning capability PHO RIVERSIDE 92507 _ +„ � PHONE-.(951)<OS-1-1733 number Of roof penetrations Moderate load capability Heavy load capability Extreme load capal W lity WW CRENG CO 4 Clear 8 black anodized finish Clear 8 black anodized finish Clear anodized finish and the amount of �� Internal splices available Internals splices available Internals splices available P P P CONTRACTORINFO installation time. 4 Rail Selection a 0 The table below was prepared in compliance with applicable engineering codes and standards."Values are D based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof EZSYS Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.cos.com Licence-ME-52689 Force-Stabilizing Curve 90 (MASTER ELECTRICIAN) Sloped roofs generate both vertical and lateral Licence-HI-67461 forces on mounting rails which can cause them to i 120 (SUFFOLK HOME IMPROVEMENT) bend and twist.The curved shape of XR Rails® None is specially designed to increase strength In both 140 XR10 XR100 XR1000 directions while resisting the twisting.This unique Solar Individual feature ensures greater security during extreme 160 weather and a longer system lifetime. r--- Permit Package 90 PATRICIA LOWRY 120 20 r—-- �� " r' 140 14.450KW Grid Tied ,,.�• ; 160 Photovoltaic System _ 90 6970INDIAN NECK LN, 30 160 PECONIC, NY 11958 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials Rev Description Date 90 A INITIAL DESIGN 4/2/2024 XR Rails'are IronRidgeX offers All XR Rails"are made of 6000-series 40 compatible with a range of tilt leg aluminum alloy,then protected with an 160 - A UPDATED DESIGN 6/25/2024 A FlashFootR and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing 1 80 160 OPPORTUNITY PATRICIA LOWRY attachments. applications. a more attractive appearance. - 120 160 PROJECT# 8866 --_ DATE DRAWN 612512024 'Table is meant to be a sin oitfted spar chart for conveying general rail ca__ ,.use approved certification letters for actual desk. DRAWN BY E.R SHEET# PV-12.3 a 2023 IronRillige,Inc.Ail rights reserved.lirrsit i,vww-ironridge.com or call 1-800-227-9523 for more information.Veirsion 1.22 ,��_ TITLE RAIL SPEC Page'1 of 2 Current 09/10/2024 Renewables ELEMENT ENERGY LLC. Engineering Subject: Structural Certification for Installation of Residential Solar Job: Lowry Residence Project Address: 6970 Indian Neck Lane, Peconic, NY, 11958 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of ELEMENT ENERGY LLC.. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 oF NEW), A. �g00'p.F Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com o 106793 F SNP Signed on:09/10/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page2of2 Summaries: Check 1: Shingle roofing supported by 2x6 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 16 degrees and has a max beam span of 11.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x6 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 32 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com ROOF MOUNT SOLAR PERMIT PACKAGE CODE INFORMATION THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC PATRICIA LOWRY ; POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2020 INTERNATIONAL BUILDING CODE 2020 INTERNATIONAL RESIDENTIAL CODE 14.450KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 INTERNATIONAL EXISTING BUILDING CODE ��-0F NEW y 2020 INTERNATIONAL FIRE CODE O�RI A. O,p 6970 I N D IAN NECK LN P ECO N IC NY 11958 2020 INTERNATIONAL MECHANICAL CODE o R l l 2020 INTERNATIONAL PLUMBING CODE it " 2020 INTERNATIONAL ENERGY CONSERVATION CODE 2017 NATIONAL ELECTRICAL CODE BUILDINGINFORMATION 106793 THESE DRAWINGS ARE SUBJECT TO FO v COPYRIGHT PROTECTION BY US LAW. IN ANY FOM IS 2 STORY HOUSE SINGLE FAMILY RESIDENCE ACCOUNT NO. : 9641541206 FESSIONP� EXPRESSLY TORBIDDENWITHOUTPRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U METER NO: 98300265 AHJ : TOWN OF SOUTHOLD Exp:9/30/2025 RENEWABLES ENGINEERING INC. ROOF:COMP SHINGLE APN:1000086000700000000 Stamped 09/10/2024 WIND SPEED 128 Current PV SYSTEM SUMMARY: STRUCTURAL NOTES SNOW LOAD 25 R Ref18Wd13lES SYSTEM SIZE(DC) STC:425 x 34= 14.450KW DC 1. THESE PLANS ARE STAMPED FOR STRUCTURAL EXPOSURE CATEGORY D Engineering PTC:395.25 x 34=13.4385KW DC CODE COMPLIANCE OF THE ROOF FRAMING SYSTEM SIZE(AC) 10.88OKW AC @ 240V SUPPORTING THE PROPOSED PV INSTAI_LATION CURRENT RENEWABLES MODULES (34)HANWHA QCELLS Q.TRON BLK M-G2+425W ONLY. ENGINEERING INC. 2. THESE PLANS ARE NOT STAMPED FOR WATER 1760 C AVE SUITE J-13,RIVERSIDE CA 92507 LEAKAGE- PHONE.(951)-405-1733 WWW.CRENG.CO MICRO-INVERTERS ENPHASE: I108MC-72-M-INT 3. PV MODULES, RACKING,AND ATTACHMENT AERIAL VIEW VICINITY VIEW CONTRACTORINFO MICRO-INVERTERS QTY 34 COMPONENTS MUST FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. + TILT 16°, 32° 4. PLEASE SEE THE ACCOMPANYING STRUCTURALI AZIMUTH 235°, 145° CALCULATIONS REPORT FOR ADDITIONAL ROOF COMP SHINGLE INFORMATION. RAFTER/TRUSS SIZE 2"X6"RAFTER @ 24"O.C. 5. PRIOR TO THE COMMENCEMENT OF WORK,THE C2SYSau IRONRIDGE HALO ULTRA GRIP WITH IRONRIDGE SOLAR INSTALLER SHALL VERIFY THE ROOF FRAMING ATTACHMENT TYPE XR-100 INFORMATION BEFORE INSTALLATION AND NOT iFY < ; ELEMENT ENERGY LLC. THE EOR IF THERE IS ANY INCONSISTENCY 7470 SOUND AVENUE,MATTf1UCK, . . . EXISTING 200 AMPS MSP WITH 200 AMPS MAIN NEW YORK,11952 MAIN SERVICE PANEL BETWEEN SITE VERIFICATION AND THE FOLLOWING: PH:(631)779 7993 BREAKER ON TOP FED 2x6 RAFTERS @ 24"OC SPACING WITH A MAX services@e2sys.com INTERCONNECTION LINE SIDE TAP Licence-ME-52689 UNSUPPORTED SPAN EQUAL TO OR LESS THAN 14 FT. (MASTER ELECTRICIAN) OCPD RATING 60 AMPS Licence- (SUFFOLK HOME IMPROVEMENT) UTILITY LONG ISLAND POWER AUTHORITY • 3 Solar Individual GENERAL NOTES: 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION Permit Package �+ 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES SFiEE IT INDEX 3, PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED PATRICIA LOWRY 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5, ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 14.450KW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7, THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9, IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PV-3.0 STRUCTURAL 6970INDIAN NECK LN, 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE PECONIC,NY 11958 MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" PV-4.0 ELECTRICAL KID 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS Rev Description Date 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" PV-5.0 ELECTRICAL SLID A INITIAL DESIGN 4!2/2024 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM A 1 UPDATED DESIGN 6/25/2024 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM A2 UPDATED DESIGN sllolzozb COMPLIES WITH 690,35. PV-7.0 ELECTRICAL PHOTOS OPPORTUNITY PATRICIA LOWRY 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PV-8.O SIGNAGE 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PROJECT# 8866 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.1 PLACARD DATE DRAWN 9/10/2024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY ER 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 718"ABOVE ROOF SURFACE, PV-9.0 M ICROINVERTER CHART 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE.TYPE NM CABLE SHEET a PV-1 0 ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH PV-10.0 SAFETY PLAN TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0 SAFETY PLAN 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: PV-1 2.0+ SPEC. SHEETS R324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND SEPARATE ROOF PLANES, ENLARGED VIEW VIEW FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. INDIAN NECK L N FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE MSP MAIN SERVICE PANEL SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE INDIAN NECK L N OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS AC DISCONNECT ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS 64=)•, WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES.CONDUIT,OR 1 MECHANICAL EQUIPMENT. ' C❑ COMBINER (E) UTILITY METER R324.6.2 SETBACK AT RIDGE: FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 ❑ PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN I - MODULE AN 1B INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A i a PROPERTY LINE ��✓' THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. I , / ```�� ROOF OBSTRUCTIONS COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 , i PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A 1 MSP UM REPRODUCTION IN ANY FORM IS �g I .`' I , EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A I 'E. I I ROOF ACCESS POINT WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. 1 I �� �� ; AC RENEWABLES ENGINEERING INC. 1 tea; R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS I �� TRENCH CONDUIT AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED I ' THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE Current AND RESCUE OPENING.A36-INCH-WIDE PATHWAY SHALL BE I ": Renewables PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. A PATHWAY ON STREET I i (N) FUSED AC DISCONNECT Engineering OR DRIVEWAY SIDE OF ROOF ' B -FIRE ACCESS POINT I (E)MAIN SERVICE PANEL /// CURRENT RENEWABLES i I _ ENGINEERING INC. 36"ACCESS PATHWAYSWlErEmA = I PHONE E (951)O AVE SUITE �� ' P,��,OF Nf Iy yo J-13,RIVERSIDE CA 92507 , � I PHONE.(95,)<061733 N I _ , —:) �Rj A. C � WWW.CRENG.CO 18"ACCESS PATHWAYS "v i �00 qOF CONTRACTOR INFO 00 NOTES: 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED I I n I I ON ACTUAL SITE CONDITION AND I _ MEASUREMENTS. 863'-1" a"' 1 f V 01 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS f` 106793 CZSYSA INCORPORATED INTO THE 2017 NEC AND UL / (N) V PVC UNDER GROUND �A, STANDARD 1741. I ��FEss'll ' I 1 _ CONDUIT @ 18"BELOW 3. EXISTING ROOF VENT SHOULD NOT BE ; ; m GRADE—150'(TRENCHED) Ex 9 30 ELEMENT ENERGY LLC. COVERED. I I � p: /2025 7470 SOUND AVENUE,MATTITUCK, tV NEW YORK,11952 Stamped 09/10/2024 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 1 (MASTER Licence- I ELECTRICIAN)61 / I (SUFFOLK HOME IMPROVEMENT) i R•' � FENCE Solar Individual Permit Package 1 1 . PATRICIA LOWRY SHED ROOF OBSTRUCTION - ROOF ACCESS POINT 14.450KW Grid Tied Y Photovoltaic System 6970 INDIAN NECK LN, (N) COMBINER PECONIC,NY 11958 S r* - Rev Desalption I Date A INITIAL DESIGN 1 4/2/2024 ;77 ROOF LINE A., UPDATED DESIGN 6/2W024 ' DRIVEWAY PROPERTY LINE � Az UPDATED DESIGN s/,o/zozb 1 OPPORTUNITY PATRICIA LOWRY 1 - PROJECT# 8866 1 DATE DRAWN 9/10/2024 SITE PLAN o0 I . 31'-10" ROOF ACCESS POINT DRAWN BY ER N 1 _ SHEET# PV-2.0 1 57-6 TITLE SCALE: 1/128" = V-0" —� 82, SITE PLAN ARRAY AREA LEGEND EAVETO ROOF ROOF TOTAL #OF RIDGE ARRAY AREA AREA AREA ROOF ROOF TYPE AZIMUTH AREA MODULES DIMENSION (Sq.Ft.) COVERED BY COVERED BY (Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) UM UTILITY METER #1 COMP SHINGLE 235 7 11.4 147.14 2701 5.45 26.46 MAIN SERVICE PANEL #2 COMP SHINGLE 145 27 14.10 567.54 2701 21.01 �c AC DISCONNECT I N DIAN NECK LN c❑ COMBINER (E) UTILITY METER MODULE THESE DRAWINGS ARE SUBJECT TO ROOF OBSTRUCTIONS COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR TRENCH CONDUIT WRITTEN APPROVAL FROM CURRENT MSP UM RENEWABLES ENGINEERING INC. AC r 1 I I 1 1 Current Renewables Engineering (N) FUSED AC DISCONNECT yp �Af CURRENT RENEWABLES CA\ O�R� A• (� 'r� ENGINEERING INC. Q Ste. 0 1760 CHICAGO AVE SUITE RIVERSIDE CA 92507 (E)MAIN SERVICE PANEL PHONE(951)d05-1733 WWW.CRENG.CO r W CONTRACTORINFO �2 106793 FESSIONP� a ® r*1 -.._ Exp:9/30/2025 E 2 SYSAU N 1"PVC UNDER GROUND Stamped 09l10/2024 ( ) ELEMENT ENERGY LLC. CONDUIT @ 18"BELOW 7470 SOUND AVENUE,MATTITUCK, GRADE-150-(TRENCHED) NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied Photovoltaic System ROOF#1 6970 INDIAN NECK LN, PECONIC,NY 11958 Rev Description Date (N)COMBINER A INITIAL DESIGN 4/2/2024 A UPDATED DESIGN 6/25/2024 (N)#34 HANWHA QCELLS Q.TRON BLK A UPDATED DESIGN 9/10/2024 M-G2+425W OPPORTUNITY PATRICIA LOWRY PROJECT# 8966 ROOF#2 DATE DRAWN 9/10/2024 ROOF PLAN DRAWN BY ER 2 SHEET# PV-2 1 TITLE SCALE: 1/3Z = 1 -W ROOF PLAN ROOF ROOF ROOFING FRAMING FRAMING OC PENETRATION MAX NO TILT TYPE ATTACHMENT TYPE TYPE SIZE SPACING PATTERN PENETRATION MAX SPACING OVERHANG ROOF 1 16 COMP SHINGLE IRONRIDGE HALO ULTRA GRIP RAFTER 2"X6" 24" STAGGERED 72" ROOF 2 32 COMP SHINGLE IRONRIDGE HALO ULTRA GRIP RAFTER 2"X6" 24" STAGGERED 72" 24" A\P��'OF NE�yo *��oOE. A. C4�F'P* THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR r CI= WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 1 06793�P � CL�rrent FESS1 ti wables Exp:9/30/2025 Engineering HANWHA QCELLS Q.TRON BILK M-G2+425W Stamped 09/10/2024 CURRENT RENEWABLES ENGINEERING INC. CHICAGO AVE SUITE IRONRIDGE XR-100 J7113,RIVERSIDE CA 92507 TABLE PENETRATION PHONE (951)-405-1733 WWWCRENG.CO GUIDE FOR INSTALL CONTRACTOR INFO 4" � (E)COMP SHINGLE TWO OR MORE ROWS OF PANELS 1 -17 IM ® M 2s•MIN'ENeED. IRONRIDGE HALO ULTRA GRIP Cc SYS I I I I I I I I I I I I I I I I I I I I #14 X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING I I I I I I I I I I I I I I I I I I I I ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, RAFTER NEW YORK,11952 PH:(631)779 7993 I I I I I I I I I I I I I I I I I I I I Licence-ME-52689 (E)2"X6"RFER@ 24"O.C. (MASTER ELECTRICIAN)VIEW Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) IRONRIDGE XR-100 STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE HALO ULTRA GRIP Permit Package HANWHA QCELLS Q.TRON BLK M-G2+425W ONE ROW OF PANELS PATRICIA LOWRY SEE ENLARGED VIEW 4,4 14.450KW Grid Tied I I I I I I I I I I I I I Photovoltaic System (E)2"X6"RAFTER@ 24"O.C. I I I I I I I I I I I I I 6970 INDIAN NECK LN, TT T T PECONIC,NY 11958 A 1 1 AChMEN I DE I AIL FULLY STAGGERED STACKED/STAGGERED Rev Description Date (E)COMP SHINGLE A INITIAL DESIGN 4/vzoz4 At UPDATED DESIGN 6/2 512 0 2 4 A.2 UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8966 DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.33A @ 240V ACCOUNT NO. : 9641541206 45.22 X 1.25 = 56.53AMPS 60A FUSES-OK METER NO: 98300265 (E)UTILITY METER (E)200A RATED (N)ENPHASE MAIN SERVICE PANEL COMBINER BOX MODEL CONSUMPTION CT. 1 PH,120/240V 60HZ NO#X-IQ-AM1-240-5/5C (4)#14 AWG CL3R/CMR (E)200A/2P MAIN tR 12 AWG,SKU:Q-I2-RAW-3D0,THHN PVGPC INSULATION BREAKER AWG,BARE COPPER GROUND CONDUCTOR (TOP FED) CELL WIRE LESS TRENCHED 150' (12) IQ8MC-72- MODEM COMMS THESE DRAWINGS ARE SUBJECT TO MICROINVE R COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS BRANCH-1 IQ GATEWAY EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 12 HANWHA QCELLSQ.T RENEWABLES ENGINEERING INC. BLK M-G2t 425W N)I5A:� (N)60A FUSED PRODUCTION CT r AC DISCONNECT (11) IQ8MC-72- I SQUARE D D322NR6 —(N)uNESIDE TAP VIA uL Current MICROINVER (N)20A/�\ r\ i WITH 60A FUSES, � LISTED CONNECTOR BRANCH-2I N120APi KNIFELOCKABLE,NEDE,3R, Qg p {� 11 HANWHA QCELLSQ.T _ //''�\ 4`A+ 4+Wa�+'eS BLK M-G2+425W (N)20Am UL LISTED/11 TO OVERFiE o Engineering (11) IQ8MC-72- ------ ------------ qfe --- --- 1 FEEDMICROINVERI ----- I CURRENT RENEWABLES BRANCH-3I I ENGINEERING INC. 11 HANWHA QCELLSQ.TRON I 3-#4 AWG,THWN 3-#6 AWG,THWN 1760 CHICAGO AVE SUITE BLK M-G2+425W r —J 1-#8 EGG THWN PHOJ-13NE. RIVERSIDE-1 92507 1-#6 EGC,THWN PHONE: 951)3051733 IN 1"PVC UNDER IN 3/4"OR LARGER PVC L——————————— WW .CRENG.CO GRO W UND CONDUIT @ 18" CONDUIT BELOW GRADE-150' CONTRACTOR INFO (TRENCHED) (E)GROUNDING ELECTRODE CONDUCTOR#6 BARE COPPER IM ® M MODULE MANUFACTURER QCELLS CZSYS8 MODULE MODEL Q.TRON BLK QF NEIV M-G2+425W '��' rb ELEMENT ENERGY LLC. MODULE(W) 425 GjP 1P 7470 SOUND AVENUE,MATTITUCK, C NEW YORK.11952 MODULE PTC(W) 399.00 * G = PH:(631)779 7993 MODULE Isc(A) 13.66 ➢ W services@e2sys.com MODULE Voc(V) 39.03 019912E = Licence-ME-52689 (MASTER MODULE Imp(A) 2.98 ?� Lic nc e ELECTRICIAN) IHII-67 61 MODULE Vmp(V) 32.74 CTR1G Ki NOTE: (SUFFOLK HOME IMPROVEMENT) V SSIO 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS STAMPED09/10/2024 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A PATRICIA LOWRY WIRE SCHEDULE STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 14.45OKW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT Photovoltaic System # EQUIPMENT WIRE LOCATION QTY. AMPACITY RATING (°C)WIRE FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 6970INDIAN NECK LN, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY PECONIC,NY 11958 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.66 0.96 1 28.80 17.08 Rev Description I Date A INITIAL DESIGN 4!2/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 15.96 0.96 1 28.80 19.95 Al UPDATED DESIGN 6zs2oz4 A UPDATED DESIGN 1 9/10/2024 3 AC COMBINER TO AC DISCONNECT TRENCH 3 4 95 90° 45.22 0.96 1 91.20 56.53 OPPORTUNITY I PATRICIA LOWRY PROJECT# 8866 4 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 45.22 0.96 1 72.00 56.53 DATE DRAWN 9/10/2024 DRAWN BY ER SHEET It PV-4.0 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.33A @ 240V 45.22 X 1.25 = 56.53AMPS 60A FUSES-OK ACCOUNT NO. : 9641541206 METER NO: 98300265 (E)UTILITY METER OOA RATED (N)ENPHASE MAIN SERVICE PANEL COMBINER BOX MODEL i CONSUMPTION CTs 1PH,120/240V 60HZ NOF #X-IQ-AM1-240-5/5C (4)#14 AWG CL3R/CMR 2-#12 AWG,SKU:0-12-RAW 300,THHN I PVC/PC INSULATION (E)200A/BREAKER 1-#6 AWG,BARE COPPER GROUND / CONDUCTOR CELL WIRE LESS TRENCHED 150' (TOP FED) THESE DRAWINGS ARE SUBJECT TO (12) IQBMC-72-M-INT MODEM COMMS -- _ COPYRIGHT PROTECTION BY US LAW. MICROINVERTERS REPRODUCTION IN ANY FORM IS IQ GATEWAY EXPRESSLY FORBIDDEN WITHOUT PRIOR BRANCH-1 i WRITTEN APPROVAL FROM CURRENT 12 HANWHA QCELLSQ.TRON N m RENEWABLES ENGINEERING INC. BILK M-G2+425W N)15A-� + (N)60A FUSED PRODUCTION CTs AC DISCONNECT (11) IQ8MC-72-M-INT -- SQUARE D D322NRB N LINESIDE TAP VIA UL MICROINVERTERS N)20A./n WITH 60A FUSES, LISTED CONNECTOR Current BRANCH-2 N)20A KNI FEBLADE, 11 HANWHA QCELLSQ.TRON N LOCKABLE,NEMA 3R, BLK M-G2+425W N)20A ( UL LISTED ./ Engineering OVERHEAD UTILITY OVERHEAD (11) IQBMC-72-M-INT — oJe FEED CURRENT RENEWABLES MICROINVERTERS ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 3-#4 AWG,THWN 3-#6 AWG,THWN PHONE:(951)-405-1733 11 HABUK M QCELLSQ.TRON N 1-#6 EGC,THWN 1-#8 EGG THWN PHONE (ENG.CO BLK M-G2+425W IN 1"PVC UNDER IN 3/4"OR LARGER PVC GROUND CONDUIT @ 18" CONDUIT CONTRACTOR INFO BELOW GRADE-150' - (TRENCHED) C GROUNDING ELECTRODE CONDUCTOR#6 BARE COPPER im IN MODULE MANUFACTURER QCELLS Cc-'SYS� MODULE MODEL Q•TRON BILK OF NEtv M-G2+42SW �� y0 ELEMENT ENERGY LLC. MODULE(W) 425 y�Q' ���MAN�� 7470 SOUND AVENUE,MATiITUCK, MODULE PTC(W) 399.00 * �� O'G * NEW YORK,11952 Z PH:(631)779 7993 MODULE Isc(A) 13.66 D W services@e2sys.cam MODULE Voc IV) 39.03 Z 09912B 2 Licence-ME-52689 (MA MODULE Imp(A) 2.98 , Licence- s n e ELECTRICIAN) 61 < MODULE Vmp(V) 32.74 CTMFRt NOTE: (SUFFOLK HOME IMPROVEMENT) '�D� �. �(J/FSS10tip- 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS STAMPED 09/10/2024 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A PATRICIA LOWRY WIRE SCHEDULE 14.450KW Grid Tied STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM Photovoltaic System AWG CURRENT FACTOR FOR ADJUSTED CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO 6970 INDIAN NECK LN, # QTY. AMPACITY RATING (°C) FACTOR PECONIC,NY 11958 SIZE 310.15(B)(16) CONDUCTORS IN 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS RACEWAY 310.15(B)(3)(a) IN RACEWAY Rev Description Date A INITIAL DESIGN 4/2/2024 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.66 0.96 1 28.80 17.08 Al UPDATED DESIGN 6/25/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90, 15.96 0.96 1 28.80 19.95 A2 UPDATED DESIGN 911012024 OPPORTUNITY PATRICIA LOWRY 3 AC COMBINER TO AC DISCONNECT TRENCH 3 4 95 90° 45.22 0.96 1 91.20 56.53 PROJECT# 8866 DATE DRAWN 9/10/2024 4 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 45.22 0.96 1 72.00 56.53 DRAWNBY ER SHEET# PV-5.0 TITLE ELECTRICAL SLID MATERIAL LIST ��pF NEWY ELECTRICAL EQUIPMENTS QTY. PART TYPE PART NUMBER DESCRIPTION 4u v 34 MODULE Q.TRON BILK M-G2+425W QCELLS Q.TRON BLK M-G2+425W m �912MB 2 34 MICROINVERTER IQ8MC-72-M-INT ENPHASE IQ8MC-72-M-INT ZN�O CTR10P� - 1 FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED AROFEssl�P� 1 COMBINER X-IQ-AM1-240-5/5C ENPHASE COMBINER BOX X-IQ-AM1-240-5/C STAMPED09/10/2024 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO BREAKER / FUSES CONTRACTOR INFO QTY. PART TYPE PART NUMBER DESCRIPTION 1 FUSES 60A FUSES GENERAL 60A FUSES a IN ntf 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) E2SYS9 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) RACKING (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 40 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK Permit Package 26 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 PATRICIA LOWRY 82 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK 28 CLAMPS & GROUNDING UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK 14.450KW Grid Tied 7 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE Photovoltaic System 129 ATTACHMENTS FF2-02-132 FLASHFOOT2, BLACK 6970 INDIAN NECK LN, PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 1 4/2/2024 AA UPDATED DESIGN 6/25/2024 A.2 UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8966 DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-6.0 TITLE BOM EXISTING SERVICE PANEL PHOTOS �<__of: NEhrY r D W CTRI0991 STAMPED 09 10 2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current n abler Engineering _ CURRENT RENEWABLES r ENGINEERING INC. 1760 CHICAGO AVE SUITE - _ J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 VWVW.CRENG.CO CONTRACTOR INFO EZSYSA ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEME" „ t Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 A.1 UPDATED DESIGN 6/2 512 0 2 4 A 2 UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8966 DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-7.0 TITLE ELECTRICAL PHOTOS PHOTOVOLTAIC SYSTEQUIPPED — RAPID SHUTDOVVN - sso.1 z THESE DRAWINGS ARE SUBJECT TO - - , • COPYRIGHT PROTECTION BY US LAW. TURN RAPID REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR SHUTDOWN SWITCH TO RATED A OUTPUT CURRENT 45.22 AMPS WRITTEN APPROVAL FROM CURRENT THE "OFF" POSITION TO AC AC RENEWABLES ENGINEERING INC. NORMAL •' • VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current AND REDUCE SHOCK Renewables HAZARD IN THE ARRAY y Engineering 690.56(C)(1)(B) PM DUAL POWER SOURCES SECOND SOURCE PHOTO-VOLTAIC CURRENT RENEWABLES RATED . , / OUTPUT • CURRENT - 45.22 AMPS ■ ENGINEERING INC. 1760 CHICAGO AVE SUITE (- J-13,RIVERSIDE CA 92507 AC NORMAL OPERATING VOLTAGE / VOLTS PHONE:(951)-405-1733 WW W.CRENG CO CONTRACTORINFO 69054 OPTIONAL SOLAR LOAD CENTER ARRAY EZSYSUA ELEMENT ENERGY LLC. J/B 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 ■ ■ • ■ • • (MASTER ELECTRICIAN) 1• • ■ • (SUFFOLK HOME IIMPROVEMENT) NEC 690.31(G)(3)&(4),CRC R324.7 OVERCURRIENT DEVICE "WARNING" Solar Individual (UNLESS BUSBAR IS FULLY RATED) - Permit Package 705.12(D)(2) PHOTOVOLTAIC POWER • • PATRICIA LOWRY EVERY 10'ON CONDUIT AND ENCLOSURES 14.450KW Grid Tied for NEW Photovoltaic System NOTES: �P� oEr�wv, op 6970INDIAN NECK LN, dO � PECONIC,NY 11958 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS yt G SHOWN HEREON. r- Qj v Rev Description Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: m 099128 W A INITIAL DESIGN 4/2/2024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR Al UPDATED DESIGN 6/2 512 0 2 4 P� MACHINE PRINTED LETTERS OR ELECTRO-PLATING. CTRtG A UPDATED DESIGN 9/10/2024 � OPPORTUNITYPATRICIA IOW RV PAT B. RED BACKGROUND COLOR WHITE TEXT AND LINE 5S10 WORK. PROJECT# PAT 8866 C. AERIAL FONT. STAMPED 09/10/2024 DATE DRAWN R110/2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY E.R THE LOCATIONS PECIFIED. SIGNAGE CANNOT BE SHEET# PV-8.0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. CAUTION REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. PV ARRAY 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)405-1733 WWW.CRENG.CO Z CONTRACTORINFO Y H of N S;V y0 Z �P�ooE ul�nv,�c'Q� L, ? * ® --•- 0 n D W MAIN SERVICE PANEL Z Z 099128 2 CcSYS8 q� CTR1Gr� ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 COMBINER AC DISCONNECT STAMPED 09/10/2024 PH:(631)779 7993 services@e2sys.com UTILITY METER Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PATRICIA LOWRY PANEL IS AC DISCONNECT PER NEC690.17 14.45OKW Grid Tied Photovoltaic System 6970 INDIAN NECK LN, PECONIC,NY 11958 Rev Description Dale A INITIAL DESIGN 4/2/2024 A.1 UPDATED DESIGN 6/25/2024 A.2 UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8966 DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-8.1 TITLE PLACARD MICROINVERTER CHART 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current Renewables Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW CRENG.CO CONTRACTOR INFO 5 a 0 r*1 EPSYSA ELEMENT ENERGY LLC. 6 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package PATRICIA LOWRY 14.450KW Grid Tied$ Photovoltaic System 6970 INDIAN NECK LN, PECONIC,NY 11958 Rev Description I Date A INITIAL DESIGN 1 4/2/2024 9 A UPDATED DESIGN 1 6/25/2024 A UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 9/10/2024 DRAWN BY E.R 10 SHEET# PV-9.0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS- THESE DRAWINGS ARE SUBJECT TO ❑c COMBINER COPYRIGHT TPROION TECTION ANY ORM IS LAW.1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. EXPRESSLY FORBIDDEN WITHOUT PRIOR 2.SAFETY PLAN MUST BE MARKED BEFORE JOB Ac AC DISCONNECT WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN RENEWABLES ENGINEERING INC. 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE MSP MAIN SERVICE PANEL &MAKE NOTES ON THE JHA SHEET ent IN CASE OF EMERGENCY UTILITY METER- Cu ewables NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC OP PERMANENT ANCHOR Engineering CURRENT RENEWABLES NAME: ENGINEERING INC. TO TEMPORARY ANCHOR J-13 RIVERSIDE AVE SUITE ADDRESS: J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 IL INSTALLER LADDER WWW CRENG CO SAFETY COACH CONTACT INFORMATION NAME: CONTRACTORINFO STUB-OUT ADDRESS: ® SKYLIGHT a Im rN ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE NO LADDER ACCESS (STEEP GRADE Cc SYS SAFETY PLAN AND SIGN INDICATING THAT THEY ARE OR GROUND LEVEL OBSTRUCTIONS) AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. ❑ RESTRICTED ACCESS ELEMENT ENERGY LLC.7470 SOUND AVENUE,MATfITUCK, TRENCH NEW YORK,11952 NAME SIGNATURE PH:(631)779 7993 GAS GAS SHUT OFF services@e2sys.com Licence-ME-52689 zo WATER SHUT OFF (MLSTEnReLHI-67 61 O (SUFFOLK HOME IMPROVEMENT) � SERVICE DROP OSolar Individual Z POWER LINES Permit Package PATRICIA LOWRY 14.450KW Grid Tied Photovoltaic System 6970INDIAN NECK LN, PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 DATE: TIME: A.1 UPDATED DESIGN 6/25/2024 A UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel,and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all • The site supervisor shall forecast the weather conditions at the Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations. Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below).If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure. Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with COPYRIGHT PROTECTION BY US LAW REPRODUCTION IN ANY FORM IS uneven, loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC. the ladder must extend 36"above the stepping off point. Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. • Elevated work involving the moving or maneuvering of solar If Offsite,add location name and address:bars locked in the open position,A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind I y1� Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure1— {�eW �}� S leaned a ainst a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor D • Additional notes: • Crew leader responsible for communication with the client: Engineering Name: Mobile Equipment Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment,operators must Yes, No): Heat Related Illness Prevention Phone: CURRENT RENEWABLES maintain a certification on their person for the equipment being Employees shall have access to potable drinking water that is ENGINEERING INC. 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13.RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE(951)-405-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: WWW CRENG CO P 1 9 P 1 PP q Y 9 9 • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift. Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The ® r*1 roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees CZ SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: u • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete,a fall rescue plan must be outlined and • Crew member(name/title): New employees must be acclimatized. New employees will be of what happen and when. 7470 SOUND AVENUE,MATFTUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and connect Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof Crew member(name/title): scheduled breaks during each shift. Employees must take Licence-ME-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-HI-67461 • Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and o Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed o Identify the location of the closet Occupational/Industrial Clinic perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. Define the Hazard: Method/steps to prevent incident: • All electrical work will be performed with equipment in an PATRICIA LOWRY electrically safe condition(de-energized)unless approval has If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 14.45OKW Grid Tied • Service drops and overhead electrical hazards will be If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: indentified and protected from contact as neccessa . water(location/address): Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 6970 INDIAN NECK LN, PECONIC,NY 11958 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 4/2/2024 A UPDATED DESIGN 6/2 512 0 2 4 A UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-11.0 TITLE SAFETY PLAN Q.TRON BLK 3 QXRON BLK M-G2+ SERIES n ■Mechanical Specification M-G2+ SERIES �ells Fame[ 672 in Mb in=1.19 in f ricturtingNary! �.•-�^ Weigl[t 467NpaQt2Ni�j -�---� p Rant Carer OL13 in 02 mml thermally pre-stressed glass ��`� ..r......, with art-0— technology405-425Wp 1108Cells ew*crer Campo-we film 21.8% Maximum Module Efficiency F"ae �"1Od�tla111V1""' -- -__ -- -- - C ll 6=18 monooyYeeile Q/WTUM NEO solar hall cells r_� =e,,.f. -- —---- ------ ----- - A SUBJECT T JlnalTeu bar 209�39m-32 -2 -1 QS9071n s�- T--_ �,,,,�„-,_ COPYRIGHT PROTECTION BY US LAW. (531DImm 32�Omm=1S19mtf,Prole7�On class P67,With bypass dDdaS . REPRODUCTION IN ANY FORM IS Cable 4mm'Sda cable;(y268-9nff75ptm11,(�>_68.9n[T/50mm) 1 , EXPRESSLY FORBIDDEN WITHOUT PRIOR .�,.�. ss>•,.^ Connector Staubll MG4;IP68 p,, :--_ ..-� WRITTEN APPROVAL FROM CURRENT MODEL Q.TRON BLK RENEWABLES ENGINEERING INC. ■Electrical Charaeteriafits • _._ .----___ __ _-_____ ._._ ..__.___.. . , 411111111 4W 420 4M Current MN61M PERFORMANCE AT STANOWD TEST CONDf rK*lS.STC WOWER TOLERANCE+5 W/-01M Q.RNTUM High performance Ocells N- Powwtms P cm 405 41D 415 420 425 (1 - '''Hdb��$ g l� �[� SIron Ckat Clara! IQ [A] 13M I&M L149 13m t9.66 N_Q solar cells �;,c,AVillilaW a M �� 3N � t�75 3 39«� Engineering 1:',,3,!t-.rD Tecfinoia)y with t3pcim¢ed rrrodlAe = Cumem x MPP �qR -__-. ..._ 6. W V6 ._-------- 26 ------ tM -- M --------29 - CURRENT RENEWABLES boosts module efficiency upto21.8%6 voltage e1MPP w M 31.80 3254 3234 3254 3274 ENGINEERING INC. Etficiel 4 I%] 2207 22W 22t3 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 25� A reliable investment LW4 �BII CONDITIONS%%MOT' WWWCRENGCO .va"anty and 25-year linear _�"'g�— Pw. [W] 3oE1 309.9 3[i7 3/75 32T2 CONTRACTOR INFO E Short Mak Owma 6 [A] 10.74 Ulm aff --_.- 1094 um - E Open ar,.&yoll Va M 3596 3623 3650 3677 3Z04 c f Ctierent at MPP 4.. M 998 30.04 1.07 1D.F L46 Enduring high performance taRagea<Nivv V,�, M 30.66 3087 31A7 3t26 3t.46 -3%:t�Ya-5%a'STC"1000 Wtm1.25+2C.AM 15 3.-:u-tn g ro IFC 609DC3.'900WIm'.NMOT spec*.r;rm AM 15 .. Lm'zg-decal�iai 5eturi3y Wt1n Aa1ls iei ID Technology.Anti PID act.. ec^�1ao, µo<-S o: 31eA Ooe6eP61FON6MIMICEWARRANTY PE110 MMCEAT E2SYSAU a —�•• At rs'619"%of - Extreme weather rating du"film rnaar Thereafter nia" ELEMENT ENERGY LLC. 033%degaaation All.yew Al tectl arumtinvum a, frame- for east 9553std,m,Fe�Ao..e. 747050UND AVENUE,MATTITUCK, Y Hgn- +of NEW YORK,11952 eas up to 10 years At 1Cffi19038�E w po.YBr up fa 25 yes_ PH:(631)779 7993 $ = services@e2sys.com A.dill.+inn,lams,re—A m wreraroes fvawerraaibPSn Licence-ME-52689 Innovative all-weather technology e s a a arzudarceoceasswes _ _ _ - tcrosdt�oththe a (MASTER ELECTRICIAN) 7461 Optimal yield9,whatever the weather with elacetlellt low-light u , co-rove.ondy s Licence-HI- ROV .� moray wwsowNccwr,r £, (SUFFOLK HOME IMPROVEMENT) and temperature behaviour '°z' Solar Individual The most thorough testing TEMPERATURECO8FR1C1lIE?F75 .� s Permit Package programme in the industry Temperature Coetficem of I, a [%/K] +Q04 Temperature Coefficient of V„ 9 WK] -024 Temperature Coeffirxm of P, Y '%!IQ -0 Nominal Module Operating Temperature NMOT M109i5.4 x I�Ceiis�trle fits scar mociaw manufacturer to pass the .30 m (43t3'q PATRICIA LO W RY most compreherisirve quality programme in the industry The mew-taualityControlledPV-oftheindependentcertification ■Properties for System Design 14.450KW Grid Tied institute TlJV Rheinland. Ma<imum System Vdtsge Va,a 1000( l1000(tA) PV rradule classification Cltle■ d -- ---- - � Photovoltaic System Malumnt Series Fuse RNlkp [A DCJ 20 Fire Rating based on ANSI/UL 61730 C/TYPE 2 'see aw sneef m mmrtw -- . ----ar!sr-mtam�or; tMt Odptlae%PrM/Ply' [6s/R'] 75(i600Pa]/75(�600Pa' Permitted Module Temperature -40'F up to*185'F 2ApTter aWXp,oMlCeC Ts,,280-12 5 VWAf-15oov.9e., MOIL TAM toed,wehIPUIP - [es/fe] 113(540OPo)n13(540OPa) onconnnuousDuty I-40-C Lop to+e5'c, 6970 INDIAN NECK LN, See In,talla[+Or1 Mditsta' P E C O N I C,NY 11958 Rev Descnption Date ■Qualifications and Certificates = A INITIAL DESIGN 4/2/2024 A UPDATED DESIGN 6 �..c 61�3070W /25/2024 Ouai"'C"m:iee Pv TW _ A UPDATED DESIGN 9/10/2024 70 ffC ono.6t2152016. OPPORTUNITY PATRICIA LOW RV - The Ideal solution for: �^ OWE snce:c—p PROJECT# 8866 _ts Oav O Et:50390 _ Rooftop arrays on * � a DATE DRAWN 9/10/2024 yea- H. — residential buildings ------- - � ��� DRAWN BY ER Ocells pursues minimizing paper output in consideration of the global environment. SHEET# PV-12.0 .orc.mrna,Al+cew eellso , ,a Dwseu..o sense sC 92bl.uslk I L,or,awQ5.=ua—a-pomV acp"c TITLE nnnw,::t;CE�.v nn�nc me a.0 Spe�.R Coen!)wc S.t laOR rr-e.U 9261B.1A11 t El�r 9e9 2sY 59% EMHLL bc.gvYMOx6cam WEE w=eCtK�n v v MODULE SPEC ENPHASE ® IQ8MC Microinverter Commonly used module pairings W 260-460 Module compatibility _ To meet compatibility.PV mod Wes must be witlii the following max,input DC voltage and irwx.tnodllel.. Module compatibility can be chocked at Moor!/erelrssaanAnstatlersh ti toim teWcaknAohw. MPPT voltage range V 25-4.5 Operating range V 15-58 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Min-/Max.start voltage v 22/58 REPRODUCTION IN ANY FORM IS Max.input DC voltage y EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT M¢continuous operating DC aarem A 14 RENEWABLES ENGINEERING INC. Max_input DC short-circuit current ► 25 Current >: OYSYdYpa class DCport 3bleS °C°"tba`"eed`u"en` iriA 0Engineering PV array configuration - Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit 4 CURRENT RENEWABLES IQ8MC Microinverter Peakouputposrer VA 330 3� ENGINEERING ------ -- ---- 1760 CHICAGO AVE SUITE Easy to install Mex-ceraivasot tpAponwr VA 32D - -- - - 310 J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 Our newest 108 Series Microinverters are the 206.indus itghtwoignt and cor pact with plug-and-play Moairllgrid nre�atlaIL-L) 24 y 4 apR-plrer(L-I.X r Lry'sfirstmicrogrid-farmirg'.so6tware- s'r'l;ilePlvessa'110W WWW.CRENG.CO defined micromver ters with split-phase Power conversion capability to,convert DC per to —I— -&amika z 9Td tea: v 211E-2f14 ---- - 93-229 CONTRACTOR INFO AC power efficiently.The brain of the semiconductor-based rrucroirmwter is our proprietary power fm- catstaaticahon(PLC)between .- Max.corrietotu output clarart A t.33 TIM application-specific integrated circuit(ASIC),which enables the microinverter to operate in cor'+Porte^ts _ - rid-tied or off-grid modes.This chi is built in advanced 55-nm tech - -_- 9 -9 P n01o9Y with high-speed 1Voninal � _� - Faster irtsta"ation with simple two-were h�rW digital logic and has superfast response times to changing loads and grid events.alleviating cabling Extended constraints on battery sizing for home energy systems. AC C short A411�y �� A s circurt fault c+rnertt over fives Mots Z.JO Ifiigh productivity and reliabiity Im C Z SYS P.oduoes power even wtx.the grid is down,• Max- Ms per 20 A(L-U branch err 1' - 12 10 • -. More than one+r+ll+or-,cumulative hairs o! Total harmonic distortion testing t 6 ELEMENT ENERGY LLC. t' 7470 SOUND AVENUE,MATTITUCK, Class P'j ubI__ sated er-i— over-Rage class AC port - ■ NEWYORK,11952 Part of the Enphase Energy System, 108 Series Microinverters redefine Opi—ed for the latest high-powered Pv AC Port backfead mire t A PH:(631)779 7993 n8 Series lAicroinverters integrate with reliability standards with more than one rno` ies services@e2sys.com the 10 Battery,10 Gateway.and the million cumulative Fours of power-on lbw factor Licence-ME-52689 �� - � Ergnfnase App rrnoniforing and analysis testing,enabling an industry-ieadeg Mi-evid-fornnlg Grid-tied poodle factor(ad}wbb) _ 0.85 Mwdrtg_O.gs M09irW (MASTER ELECTRICIAN) Licence-H I software. limited warranty of up to 25 years PR OV • Corrpiies wiMtftelatest advanced grd Peatelfkiwtgr 1< 97A 972 (SUFFOLK HOME IMPROVEMENT) support CEC weqtled alliciency % 97D 96.5 Remote automatic updates fa the latest grid wr , Solar Individual requvemems pplrtlatepareraorrtaaptlm 25 Configurable to support a wde ran grid of gr Permit Package profiles Mabferataltgwariveno a -401C to 65'C(-40'F to 149'F) — -- Meets CA Rule 21(UL 1741-SA)and Raltttilne hrateddy rare 4%to 100%fportderttng) PATRICIA L WRY Connect PV modules quickly and easily K28 Series Microinverters are UL Listed IEEE 1547:2018(UL 1741-SB) to the 108 Series Microinverters that have as PV rapid shutdown equipment and DC two Sta"MC4 integrated MC4 conrnectors. conforms with carious regulatiorn 1Mhef1 MOTE,, -Dinteutaans(H(H-WW•o}.Weight 212 min(8.3.)•175 mm(6.9•)-302 mm(12•);1.1 kg(2.43 ibs) 14.450KW Grid Tied installed according to the manufacturer's Photovoltaic System If132n1CtKWM fQ8Pre Mvoewe•tei cannon be mixed togethei twee with Coding Natural convection-no fans Y Previous griraton W Enphase mivoewerters (107 series•rob sense and so m)n tip,same Approved for wet locations;Pollution degree yes;PD3 �- Enclosure Class ll double-insulated,corrosion-resistant polymeric enclosure 6970 INDIAN NECK LN, 10 Mtaceriwten 9*with default settings that meet North Amain s IEEE t547 er[ercariection Environ-category,UV exposure rating NEMA Type 6;outdoor P E N I 5 standard mgwwrxits.Region-speci/c Rev Description Dale adFrslmems may be requested by by an Authority Huey Jtrrtsticticn(A/U)or tinily iapresenttvive. A INITIAL DESIGN 4/2/2024 'Meets UL T741 drily when eotaaed-1h b System Cont,,Ow 2 w 3 An 10 Geeway a requinid to make these changes CA Rule 21(UL 1741-SA),UL 62109-1.IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B.ICES-0 03 Clash B.CAN/CSA-C222 NO.107.1-01. A.1 UPDATED DESIGN 6/25/2024 ding irwagiiih rtifi - Certifications This product is UL Listed as PV rapid shutdown equipment pment and conforms with NEC 2014.NEC 2017,NEC 2020,and NEC 2023 section 690.12 and C22.1-2018 Rule 64-2I8 rapid shutdown of PV systems for AC and DC conductors when installed accordeg to the manufacturer's instructions. A.2 UPDATED DESIGN 9/10/2024 O 2024 Erplo Energy Ae rdlw rr word Eephaws the a anc CC"gore.IQ and cenam a,iie,mats feted az (U No enforced R.IAC,abn OPPORTUNITY PATRICIA LOW RV nnpsJrwipfrwemi/trademrrk-taaga•oJdaitsary trademarks or Epnwa Energy.hie.in the US.and otter euurrtr;es. Datasugmcillo ya IOBMC-MC4-OSH-00049-4D-ENHIS-2024-02-09 3) ma._.army.Refe-totoWa�idW�dmme if bead by tfrutirity peMC-MCA-OSH-00049-4.0-EN-US-2024-02-09 PROJECT# 8966 regrewrtwttstotlsM1ialhe rarrltber W irticreeniartws Per brertch n your area DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-12A TITLE MICROINVERTER SPEC v ENPHASE. ® IQ Combiner 5/5C it _ 10 Combiner 5 with 10 Gateway printed circuit board for integrated revenue-grade PV production IQ Combiner 5(x-KI-AMI-240-5) metering(ANSIC1220 tO.596).consumption monitoring(t 2.5%).and IQ Battery monitoring(1.5%). Includes a silver solar shield to deflect heat. ENP—ASE 10 Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production 10 Combiner 5C(X.-10-AM1-240-5C) metering(ANSI C122010.5%).consumption monitoring(2.5%)and 10 Battery monitoring(t2.5%). Includes Enphase Mobile Connect cefiJar modem(CELLMODEM-W-06-SP-05)'.Includes a silver solar shield to deflect heat. THESE DRAWINGS ARE SUBJECT TO Io Gateway printed circuit board 10 Gateway is the platform for total energy management for comprehensive,remote maintenance.and COPYRIGHT PROTECTREPRODUCTION IN ANY ORM IS BY US LAW management of the Enphase Energy System EXPRESSLY FORBIDDEN WITHOUT PRIOR Bulbar 80 A busbar with support for 1•IQ Gateway breaker and 4.20 A breaker for installing K)Series WRITTEN APPROVAL FROM CURRENT Microinverters and Q Battery 5P RENEWABLES ENGINEERING INC. IQ Gateway breaker Circuit breaker.2-po4e.10 A/15 A Production CT Pre-wired revenue-grade solid core CT.accurate up to/05% errant X-IQ-Allltl-240-5 Consumtroon CT Two consumption metering clamp Crs.snipped with the box.accurate up to 25% 11e i,w able s X-10-AM1-240-5C IQ Battery CT One battery meteringclam CT,shipped p ppedwith the box.accurate upto2.5% Engineering CTRL board Control board for wired communication with IQ System Controller 3/313 and the 10 Battery 5P Q Combiner 5/5 C Enphase Mobile Connect(only with IQ Combiner 5C) 4G-based LYE-M,cellular modern(CELLMODEM-kn-06-SP-05)with a 5-year T�10 We data plan URRENT RENEWABLES ENGINEERING INC. Accessories kit Spare control headers for the COMMS-KIT-02 board 1760 CHICAGO AVE SUITE Smart J-13,RIVERSIDE CA 92507 The 10 Combiner 5/5C consolidates interconnection equipment into a single enclosure and PHONE:(951)-405-1733 streamlines 10 Series Micro nverters and 10 Gateway installation by providing a consistent. Includes 10 Gateway for WAW CRENG CO pre-wired solution for residertial communication and control p appGCatiors.IQ Conbcter 5/SC uses wired control CELLMODEM-MI-06-SP-05 sG-based LTE-Mt cellular modem with a 5-year T-Mobile data plan CONTRACTOR INFO oonnnurlication and is compatible with 10 System Controller 3/3G and 10 Battery 5P. trnciudes Enphase Mobile Connect CELLMODEM-MI-O6-AT-05 4G-based LTE-Ml cellular modern with a 5-year AT&T data plan (CELLMODEM-MI-06-SP-05).only The 10 Combiner 5/5C-10 Series Microinverters,10 System Controller 3/3G.and K)Battery with 10 Combiner 5C Supports Eaton BR2XX.Siemens Q2XX and GE/ABB THOL2IXX Series circuit breakers(XX represents 5P provide a Complete grid-agnostic Enphase Energy System. Circuit breakers(off-the-shelf) 10.15.20.30-40.50.or 60).Also supports Eaton BR220EL BR230B,and BR2406 circuit breakers • Supports flexible networking:Wi-Fi, compatible with the hold-down kit. EthernleL or cellular BRK-IO Ila a El Provides production meteringCircuit breakers(provided by Enphase) 240V-6(more de BRK-15A-2-24Ov.BRes'se 2P-240V.�(-GA-2P-210V-0.and BRK-20A-2P- 240V-e(moredetailsa+tite'Accessorres'section) C2SYSA (revenue grade)and consumpiion It morlitorirlg XA-SOLARSfWLD-ES Replacement solar shield for 10 Combiren 5/5C XA-ENV2-PC6A-5 10 Gateway replacement prated circuit board(PCB)for 10 Conbmz 5/5C ELEMENT ENERGY LLC. Easy toinsta! 7470 SOUND AVENUE.MATTRUCK.6X-IQ-NA-HD-t25A Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws) NEW YORK,11952 10 Series Microinverters 10 System Controller 3/3G Mounts to one stud with centered PH:(631)779 7993 The high-powered smart grid-ready 10 Series Provides microgri l mtercormnecbon brackets XA-COMMS2-PCSA-5 Replacement nt COMMS-KR-02 parted crcJrt board(PCB)for IQ Combiner 5:5C services@e2sys.coin Microinverters(106.107,and 108 Series)simplify device(MID)functionality by Supports bottom.back.and side Licence-ME-52689 the installation process. automatically detecting grid failures and condlMerltries (MASTER ELECTRICIAN) seamlessly transtionirg the home energy Rating BOA Licence-HI-67461 system from grid power to backup power. Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers System voltage and frequency 120/240 VAC.60 Hz (S U FFO LK HOME IMPROVEMENT) --- (not included) Busbar rating 125 A y' 80 A total PV branch circuits Solar Individual Fault current rating 10 kAIC Bluetooth-basedWi-Fiprovisioning Permit Package for easy Wi-Fi setup Maxrmum continuous current rating(input from PV/storage) 64 A F` Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR Siemens Q.or GF/ABB THQL Series distributed generation(DG)breakers PATRICIA LO W RY Reliable only(not included) 10 Battery 5P IQ Load ControllerDurable NRTL-cert Pied NEMA type 3R Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with 10 Gateway breaker included 14.450KW Grid Tied Fully integrated AC battery system.Includes six Helps prioritize essential appliances enclosure (p Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included Photovoltaic System field-replaceable I08D-BAT Microinverters. during a grid outage to optimize energy 5-year limited warranty consumption and prolong battery life. Production metering CT 200 A solid core pre-installed and wired to IQ Gateway • 2-year labor reimbursement program 69701NDIAN NECK LN, coverage included for both the Consumption monitoring CT(CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box PECON I C,NY 11958 10 Combiner SKUs 200 A clam current transformer for 10 Batter meteri q Battery metering CT clamp-style v rig,Irlckuded with the boa UL1741 Listed - - -- ._. Rev Description Date us NON A INITIAL DESIGN 4/212024 C @A.1 UPDATED DESIGN 6/25/2024 Lam 1 Apka-aM piryldinmal-grade cell modern for systems of up to 60 micro ti rters.Available In the United stated Canada.Maxi Puerto Rico.and the US Virgin Islands,whore there is adequate A 2 UPDATED DESIGN 1 9/10/2024 oWkdw aarvlon In the Installation area. 5-year limited OPPORTUNITY I PATRICIA LOW RY warranty PROJECTS 8866 'For country-specific warranty information.see the httm*J/orohasecom/-wmWlwVresouces/warramy page. DATE DRAWN 9/10/2024 O 2024 Erphase Energy.AM nghb reserved.Erplwe.the a and CC logoa.Kl and certain oew marb r1Yed of DRAWN BY E.R htmsJ/erphasasam/tradamark-rsaoe-a1daC+vs are trademarks of Erphaw FrmW Inc in the LLS end odw counaiea SHEET# W-12.2 Data s bl-t to change. IOC-5-5C-DSH-OOOo7-3.0-EN-US-2024-03-01 IOC-5-5C-DSH-00007-3.o-EN-US-2024-0YO7 TITLE COMBINER SPEC Security And Alarm Cable ""I'='"'CABLF EMi•VY N1G DISTRIBUTION• CL3 • THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. yT ��_ _ _ Current roduct onstruction Applications CURRENT RENEWABLES Conductor: • Power limited control circuits ENGINEERING 60 c CAGGO AVE SUITE. • Stranded bare copper to ASTM B 3,B 8,and&286 • Wiring of the llowing systems J-13 RIVERSIDE CA 92507PHONE(951)d05-1733 Insulation: Intercom WWW CRENG CO • Color Coded SR-PVC 0 Security Shield: -Audio CONTRACTOR INFO • Overall polyester supported Aluminum foil 0 Suggested Voltage Rating:300 Volts • Stranded tinned copper drain wire Standards Jacket NEC Article 725 Type CL3R • Gray n • Includes ripcord Cz SYSA COLOR .. Cond.# Color ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 1 Black NEW YORK.11952 2 White PH:(631)779 7993 services@e2sys.com 3 Red Licence-ME-52689 (MASTER ELECTRICIAN) 4 Green Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Part# AWG Conductors •n Thickness Jacket Thickness Nom. O.D. • Solar Individual DS11402 14 2 .013" .015" .245" 40.3 Permit Package DS11403 14 3 .013" .015" .253" 54.3 DS11404 14 4 .013" .015" .269" 70 PATRICIA LOWRY DS11202 1 12 1 2 1 .013" 1 .015" 1 .281" 1 60 1 14.450KW Grid Tied Photovoltaic System Note:The data shown is approximate and subject to standard industry and manufacturer tolerances. 6970 INDIAN NECK LN, PECONIC,NY 11958 Rev Description Date A INITIAL DESIGN 4/2/2024 A.1 UPDATED DESIGN 6/25/2024 A2 UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY PROJECT# 8866 DATE DRAWN 9/10/2024 DRAWN BY ER Selling Exclusively Through Electrical Distribution Since 1977 1 phone.(800)292-OMNI I website.omnlcable.com SHEET# PV-12 3 Atlanta•Boston•Charlotte•Chicago•Denver•Houston•Los Angeles•Philadelphia•San Francisco•Seattle•St.Louis•Tampa TITLE CL3R WIRE SPEC Adkk IRONRIDGE XR Rail° Family XR Rail®Family The XR Rail®Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location,there is an XR Rail"'to match. THESE DRAWINGS ARE SUBJECT TO Over their lifetime. solar panels experience countless ire COPYRIGHT PROTECTION BY US LAW. _ •t+� REPRODUCTION IN ANY FORM IS extreme weather events. Not just the worst storms in years, i EXPRESSLY FORBIDDEN WITHOUT PRIOR but the worst storms in 40 years. High winds capable of WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. ripping panels from a roof, and snowfalls weighing - enough to buckle a panel frame. '`----._"`"-,. Current XR Rails"'are the structural backbone _ _ S preventing these results.They resist uplift.. XR10 XR100 XR1000 } protect against buckling and safely .eF Engineering XR10 is a sleek.low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among and efficiently transfer loads into the rail,designed for regions with light or mounting rail.lt supports a range of solar mounting rails It's built to handle building structure.Their superior no snow If achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 CURRENT RENEWABLES while remaining fight and economical. to 10 ft. f for applicationsENGINEERING INC. spanning capability requires fewer . maximizing spans up feet feet commercial . 1760 CHICAGO AVE SUITE roof attachments, reducing the 6'spanning capability 10'spanning capability 12 spanning capability J-13,RIVERSIDE CA 92507 • Moderate load capability Heat/ load PHONE:(951)-405-1733 number of roof penetrations I y y capability Extreme load capability WWW CRENG.CO • Clear&black anodized finish Clear&black anodized finish Clear anodized finish and the amount Of Internal splices available Internal splices available Internal splices available CONTRACTOR INFO installation time. Rail Selection rN The table below was prepared in compliance with applicable engineering codes and standards.'Values are —��� based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof C Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. ELEMENT ENERGY LLC. ,. 7470 SOUND AVENUE.MATTI LICK. •. • . Rail Span NEW YORK,11952 i PH:(631)779 7993 Wind(MP"d services@e2sys.cos.com Licence-ME-52689 Force-Stabilizing Curve 90 (MASTER ELECTRICIAN) Sloped roots generate both vertical and lateral 120 Licence-HI-67461 forces on mounting rails which Can cause them to (SUFFOLK HOME IMPROVEMENT) bend and twist The curved shape of XR Rails ' None 140 XR10 XR100 XR1000 is specially designed to increase strength in both directions while resisting the twisting.This unique Solar Individual feature ensures greater security during extreme 160 weather and a longer system lifetime- - ------ Permit Package 90 120 PATRICIA LOWRY 20 140 14.450KW Grid Tied 160 Photovoltaic System 30 90 6970 INDIAN NECK LN, - 160 PECONIC,NY 11958 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 A INITIAL DESIGN 4/2/2024 Rev Description Date XR Rails'are IronRidge'otters All XR Rails'are made of 6000-series s � compatible with a range of tilt leg alum num alloy,then protected with an 160 A 1 UPDATED DESIGN 6/25/2024 1:1 FlashFoo?and options for flat anodized finish Anodizing prevents surface ' A 2 UPDATED DESIGN 9/10/2024 other pitched roof roof mounting and structural corrosion,while also providing ' 80 160 OPPORTUNITY PATRICIA LOWRY attachments. applications a more attractive appearance. PROJECT a ear 120 160 _. DATE DRAWN 9r10/2024 -----------------.._ - - -Table is meant to be a simplified span chart for conveying general f6 Mies.Use approved certificatior letters for act a;desigr g;ldence. DRAWN BY E.R SHEET If PV-12.4 00 0 2023 ironRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-8 -227-9523 for mom information,Version 1.22 Par TITLE // RAIL SPEC /e IRONRIDGE QuickMounf ® Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves THESE DRAWINGS ARE SUBJECT TO _ COPYRIGHT PROTECTION BY US LAW. _ REPRODUCTION IN ANY FORM IS When integrating with a home, solar attachments EXPRESSLY FORBIDDEN WITHOUT PRIOR i� / �� WRITTEN APPROVAL FROM CURRENT must be dependable for the lifetime of the rooftop. - - _- - __ • • 1�L1 RENEWABLES ENGINEERING INC Due to recent innovations. many asphalt shingles have bonded courses.A mount that protects without the need to pry shingles can really speed things up. i a i -a Current Halo UltraGrip (HUG") is here to respect the roof. -! Renewabtes Its Halo is a cast-aluminum barrier that encases the Engineering UltraGrip, our industrial-grade.foam-and-mastic seal.This allows HUG to accelerate the installation CURRENT RENEWABLES process and provide the utmost in waterproofing a eo NEERING I HI AGO AVE SUITE Hit the rafter?Good to go! Miss the rafter?Try it again. still no luck?InstaIll the rest protection. Give your roof a HUG. J-13 RIVERSIDE CA92507 When you find a rafter-you -on • -than 3 screws miss the rafter. PHONE.(951)-405-1733 Only 'D Structural Screws we needed. rafter is found.install 3rd and final screw secure six screws to deck mountWWW.CRENG.CO CONTRACTOR INFO Mutti-Ti Waterproofing` HUG utilizeszes a a multi-tiered stack of components to provide revolutionary Trusted Strength & Less Hassle waterproofing protection The Halo cast- aluminum,raised-perimeter founda,a- stxroteNlSthe UttraGnp base-a toa7� Structural capacities of HUG' were reviewed in Z mastic seal combination Mat many load directions,with racking rail running Ez SYS° .aevents water intrusion by adnenn0 seating with the shina!e sur ace cross slope or up slope in relation to roof pitch. ELEMENT ENERGY LLC. - For further details, see the HUG certification 7470 SOUND AVENUE.MATiITUCK, NEW YORK,11952 letters for attaching to rafters and decking. PH:(631)779 7993 services@e2sys.com IronRidge designed the HUG. in combination Licence-ME-52689 UaGrip Seal Technology with the RD Structural Screw to streamline (MAic n e LHI 674 ttr 61 HUG UttraGnp utilizes a stateof-the;`. Installs,which means the following: (SUFFOLK HOME IMPROVEMENT) an seal design that uses a unique, ` foam-and-mastic combination.The NO In shin I@S foam-backed adhesive provWesan a - - pry g 9 Solar Individual entirely new flashing system that - No roof nail interference Permit Package �;. conforms and adheres to every hook^:° 25-Year Warranty and cranny of composition shingles, �..Y - � Predu;.:g+:ara.^.teed?ree - • No pilot holes necessary filling gaps and shingle step-0owns No sealant(in most cases) (up to 1/8'in height) � No butyl shims needed PATRICIA LOWRY f 14.450KW Grid Tied Attachment Structural Water Seal i UL 2703 Photovoltaic System Loading Design RatingsSystem 6970 INDIAN NECK LN, •' PECONIC,NY 11958 Rev Description Date Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to A INITIAL DESIGN 422024 Mount HUG'to the root rafters the roof HUG has been and certified for the UL 441 Section UL 2703 mechanical At UPDATED DESIGN 6/252024 • • deck,or both with our custom-engineered A2 UPDATED DESIGN 9/102024 RD(rafter-or-deck)Structural Screw The RD tested and rated to compliance with 27"Rain Test"and I and bonding /1 Triple Rated 8 Certified Structural Screw anchors HUG to the roof oPPORruNlry PATRICIA rowav to Respect the Roof • . support 1004(Ibs)of the International TAS 100(A) 95 i requirements. See with an EPDM seating washer completing PROJECT# eass UL 2703 141 127) the stack of waterproofing barriers.See uplift and 368 (Ibs) Building Code& "Wind Driven Rain Flush Mount Manual DATE DRAWN 9/102024 Intertek IAs t001A)-95 backside for more installation information of lateral load. ASCE/SEI-7. Test'by Intertek. for more info. DRAWN BY E.R SHEET# PV-12 5 TITLE �- ATTACHMENT SPEC 28357 Industrial Blvd Hayward.CA 94545 28357 Industrial Blvd. 1-800-227-9523 I R O N R I D G E Hayward,-9 94545 RON RI DGE IronRidge.omr3`.'`- IronRidge.om3 Attn:Corey Geiger,COO, IronRidge Inc Date:September 7'.2021 The parameters and adjustments allowed in the span tables are defined as the following Re: Structural Certification and Span Tables for the IronRidge Flush Mount System 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1 5-1 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B(for Risk Category 11)and applicable state&local This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The county/city amendments to the IBC No special wind topographic features are included and both topographic contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(K,t)and wind ground elevation factor(Ke)are taken as 1 0 THESE DRAW NGS ARE SUBJECT TO proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape COPYRIGHT PROTECTION BY US LAW orientation and set parallel to the underlying roof surface. PV modules are supported b extruded aluminum XR Rails 3 Snow load used in the span tables is the ground snow and shall Conform to ASCE 7-16 Fig 7 2-1 and REPRODUCTION IN ANY FORM IS Y EXPRESSLY FORBIDDEN WITHOUT PRIOR applicable state&local county/city amendments to the IBC If the local jurisdiction specified snow load is in the WRITTEN APPROVAL FROM CURRENT and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof format of a flat roof snow, it shall first be converted to a ground snow following the local building code/ RENEWABLES ENGINEERING INC attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables.No special snow conditions are considered that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding,retention,or ponding snow.No rain-on-snow surcharge load is components are shown in Exhibit EX-0015. considered.The span tables do not apply to buildings which are intentionally kept below freezing.kept just above freezing.or unheated Currer The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being } listed below for the load conditions and configurations tabulated in the attached span tables Engineering (a)For ground snow no greater than 42psf:Ss 5 2.Og for Site Class A. B.C.&D. ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Ss<1.Og for Site Class A, B,C.&D CURRENT RENEWABLES ENGINEERING INC. 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:SS<_1_5g for Site Class A. B,C.&D 1760 CHICAGO AVE SUITE . 2020 Building Code of New York State(BCNYS-2020, Published in November 2019) J-13 RIVERSIDE CA 92507PHONE (951)-405-1733 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in WWW CRENG CO which the zones share the same External Pressure Coefficients(GCp). Roof zones comprising each group along Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays with each roof zones size and location are depicted in Figures 2 and 3 below each span table. CONTRACTOR INFO The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point.shall the respective loads and configurations listed,covering wind exposure categories B.C.& D.roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load ASCE 7-16 for gable&hip roof profiles..and roof slopes of 8`to 45°. The tabulated spans are applicable when the &configuration condition from the span tables,or 36". IN 51 following conditions are met: 7 Allowable span length In the charts may be multiplied by a factor of 1 08 if the rails are continuous over ��SYS0 a minimum of three spans 1 1. Span is the distance between two adjacent roof attachment points(measured at the center of the 8. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: ELEMENT ENERGY LLc. attachment fastener). 7470 SOUND AVENUE.MATTITUCK, a) XR Bonded Splice cannot be installed in the center 113 of intenor spans,or the outer 2/3 of end spans- NEW YORK,11952 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system). Spans are calculated b) BOSS Splice can be installed at any location within a span PH:(631)779 7993 om based on 2 rails stems..and conservative) deemed acceptable for 3 rails stems services-ME-5. 89 y y P y 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If Licence-ME-52689 such conditions are encountered contact supp �° g ort ironrid e.com. (MASTER ELECTRICIAN) 3. The underlying roof slope. measured between the roof surface and horizontal plane,is 8°to 45°. Licence-HI-67461 (SUFFCLK HOME IMPROVEMENT) 4. The mean roof height.defined as the average of the roof eave height and the roof ridge height measured from grade..does not exceed 30feet Solar Individual Permit Package 5 A clearance from the underside of the array to the roof surface of 2' minimum shall be provided and the height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not PATRICIA LOWRY exceed 10' 14.450KW Grid Tied 6 Module length and area shall not exceed the maximum values listed on the respective span tables Photovoltaic System 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge s Flush 6970 IN DIAN NECK LN, Mount Installation Manual and other applicable standards for the general roof construction practice PECONIC,NY 11958 Rev Description I Date A INITIAL DESIGN 4/2/2024 2021 IronRidge Inc NY Flush Mount System Certficaton Letter-1 t 2021 IronRidge Inc NY Flush Mount System Certification Letter-2 A 1 UPDATED DESIGN 6/25/2024 A UPDATED DESIGN 1 9/10/2024 OPPORTUNITY I PATRICIA LOWRY PROJECT# 9866 DATE DRAWN 9/10/2024 DRAWN BY ER SHEET# PV-12 6 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd Hayward.CA 94545 Hayward.CA 94545 RO N R I DG E 1-800-227-9523 I RON R I DGE 1-800-227-9523 IronRidge corn IronRidge com 10. Systems using CAMO module clamps shall be installed with the following guidance a) For single module installations(orphan modules)using modules with a length greater than 67 5",CAMO The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no clamps shall not be installed in regions that experience ground snow loads of 70psf and greater.Such consideration of the structural adequacy of the chosen roof attachments. PV modules,or the underlying roof supporting THESE DRAWINGS ARE SUBJECT TO scenarios are shown by asterisks in the applicable span tables. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the COPYRIGHT PROTECTION BY US LAW. b) CAMO will function within a module configuration.s design load ratings.Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array confi t REPRODUCTION IN ANY FORM IS g EXPRESSLY FORBIDDEN WITHOUT PRIOR CAMO meets the dimensional requirements shown In the figure below and that the module selected is WRITTEN APPROVAL FROM CURRENT suitable for the environmental conditions Of a particular project. = RENEWABLES ENGINEERING INC. Sincerely. g���� "v 2 0 21 .0 9.0 7 Current mcc-Ae ' 15:45: 16 Renewabl A 3 ! - i� t W F �'� = Engineering - -0 7'0 0' rwneCon+P�iM 9�f SSiO�r� CURRENT RENEWABLES X=12-2-2mn — -- ENGINEERING INC. Y=15-ADmm 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 Gang Xuan, PE PHONE t9511-405-1733 Senior Structural Engineer Www CRENG CO r X CONTRACTORINFO Figure IF CAMO A&1odLA-Fame Dimansronat Requrerrw— Span values for Exposed and Edge module conditions, as defined below,are included in the attached span ® n tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; EZ SYSD (2)The span value determined by site wind speed and ground snow load.Additionally, irrespective of the lesser span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 1. Exposed Module conditions: PH:(631)779 7993services@e25ys.com Licence-ME-52689 A module is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free (MASTER ELECTRICIAN) Licence-HI-67461 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge,rake,or (SUFFOLK HOME IMPROVEMENT) hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from its free edge to any other adjacent array or panel is greater than 4 feet. Solar Individual The allowable spans and cantilever shall only be applied to the Permit Package p y pp portion of rail directly under Exposed g Modules PATRICIA LOWRY 2. Edge Module conditions: 14.450KW Grid Tied A module Is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave, ridge.rake,or hip)is less than 2 times the height of the array(2h2) 6970 INDIAN NECK LN, where h2 Is measured from the roof surface to the top surface of the module. PECONIC,NY 11958 The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules Rev Desaipt— Date Additionally,if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered A INITIAL DESIGN 4/2/2024 for this span adjustment A 1 UPDATED DESIGN 6/25/2024 A.2 UPDATED DESIGN 9/10/2024 OPPORTUNITY PATRICIA LOWRY # G 2021 IronRidge.Inc NY Flush Mount System Certification Letter-3 's'2021 IronRidge.Inc NY Flush Mount System Certification Letter-4 PROJECT 8866 DATE DRAWN 9/10/2024 DRAWN BY E.R SHEET# PV-12.7 TITLE CERTIFICATION I Q 8 a n d Q 8+ Microinverters D ja nE3ye 'v6;Wcrozrve:^ars aT9'1�e*eL--5Wi's f rs;rnic o ir?rl �,so �raea 8'ftrts ?'.Ic'7id"�faFieT3-tea Sa.>tiF?- ?? 3s 4Vlaf^O+�` 1<314T{^ DC y^o er?fl AC;,oww s:'Fc�en>�� "+s jr3ir c;ate s rnic�� .�c r-s c*osrve'r'sr ?S r"31r 1II i!e�3r/siiC3?flr a8#'_�F@.f 7C� £r P D �ecinc ir;*e>vr circ:.)*'.�,�iiC raicroirive"e►to overare r gv�e—_lee 0r off-Bile mfl es rs c?ao +»T 55nrr,tachrciog! :high sves-d a4 icgic asc 12s super-f3s`re3joc1"se br-:es =� • r GNl flr T !c±e zo=: _s a Foy aye g d a,Auts.-ifeevi.-tillc sop sys s or,mar,ware f-=r riarl-A =MC sac ar.ergy systerns. --*sr 1h•cf+.s Part f tre nprase energy Systsm,1C8 Sshes C-9 Series a6cro!"verters-e^jetr a =iabii*y �!r a63t�in5 Wi -owmerters integrate*&the Enphase,'C 3aE*sra staneards vritr more Liar cne;-, !ic*,::umU�ee cnphase Id Gateway,and the E, rCLR' icet F E --Kv- rP�se.'�pp-rsoritcairg 'wars of paean-or+testing,aratu5ng an indusir�- and analyses sof.,ears. leading invited nerrant,,of up to 23 years. ' `rR,€rr e's 36-koflavc 3cc8tzs"f+-r Connect Pit modules quickly and easvy to 1O8 Series !Q8 Series Wicroinverters are LOL Listed as )64icroirverters using the included Q-OCC-2 adWer ?�1 R2Pid Shut Down Equipment and conform vith cable with plug-n-play MC4 connectors. various=agufartors.when!nstalted according to range?,*ct pr` manufacturer's instructions. 'Deets CA Pule r"AT74s-Sa7 9guirst_.is C 2022 Enphase Erergv.All rights reserred.Erphase,the Enphase'oge.IQ8 Micrc,rvertem,and other names are trademarks of Er rase Energy, 'Orly when nstalled nth Q System Controller 2. p rgy,Inc.Data subject to orange. meets tiL 1741. 108SP-DS-0002-01-Ei4-US-2022-03-11 "IQ8 and"QBPlus supports split phase,24011 mstailaticrs orny. 108 and IQ8+ Microinverters Commonly used module pairirgs' w 235-350 235-44C IBC-caIV120 Waif-cell 6C-cell/12C Waif-ceil 66-cell/132 raif-ceii arc 72-ceq;'4A Mccule ccmpa rl,Iy nail-cell MPPT voltage rarge v 27-37 29-45 Cperatirg rarge v 25-48 25-58 Min/max start voltage v 30/48 30/56 Max input CC voltage v 5C 60 Max DC current=(module isci A 15 Overvoltage class DC port 11 DC port backfeed current mA 0 PV array configuration ixt Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA'ACT Peak output power VA 245 30C Max ccrtirucus Cutput power en 24C 29C Nominal(L-L)vcrtage/rarge3 v 240/211-264 Max continuous outpui curreri A ',.21 Nominal frequency Hz 60 Extended frequency rarge Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max jrits per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% cvervd-tag"macs AC port III AC port>ackfeed cLrrert mil 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85lagging Peak efficiency % 975 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -40°C to+60cC(-400F to+140°F) Relative rumicity rarge 4%to IOC%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm MY)x 175 mm(6.9')x 302 mm(12') Weight 1.088 kg(2.38Ibs) Codirg Natural convector-no fans Approved for wet locations YO3 Pcllutcr degree PM Erciosure Class II double-insulated,corrosion resistant polymeric enclosure Envirer.category/UV exposure rating NEMA Type 6/outdoor i CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class 6,ICES-0003 Class 6,CAN/CSA-C222 NO.107.1-01 Certifications This product+s UL Listed as PV Rapid Shut Down.Equipment and conforms with NEC 2014,NEC 2017.and NEC 2020 section 690.12 and C22.1-2018 Rule 64-216 Rapid Shutdown of PV Systems,for AC and CC ccrductors,when rstalled according to manufacturer's instructions. (1)No enforced 0C/AC ratio.See the compatibility calculator at https://Iink.arphase.corr/module-compatibility (2:MaxiMur^continuous irput CC currert;s 10.6A(3)Ncmirai voltage range car be extended teyend remiral J reowred tv 1,e (4,-m:tS may,ar i.Aefer to ec&recuirerrerts tc eefire tre r,:rr.te,cf^ncrctr-.oerters cer trarcr'-r/cur area. iCBSp-CS-CCC2-01-EN-US-2C22-C3-1? I ONRIDGE Flush Mount System IronAidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified.. code compliant and backed by a 20-year warranty. Strength Testes � PE Cer$atied QAll components evaluated for superior � Pre-stamped engineering letters structural performance. available in most states. Class A Fire dating - design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects .�r a UL 2703 Listed Sys#em 20-Year Warranty Entire system and components meet ` Twice the protection offered by newest effective UL 2703 standard. competitors. XR10 Rail XF1100 Mail XP1000 RailBonded Slices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. f' rail for commercial projects. for seamless connections. S' spanning capability 8'spanning capability ri' • 12'spanning capability ° Self-drilling screws Moderate load capability Heavy load capability • Extreme load capability ° Varying versions for rails Clear and black finish 7,Clearnd black finish Clear anodized finish • Forms secure bonding UFIOS �_�_ SWppea Sileeves Gv'Dunding Lugs M�crvanertw Ails r '- '`--4A Universal Fastening Objects Snap onto the UFO to turn ys to Mount Mls or Rfls to XR bond modules to rails, into a bonded end clamp equipment ground. Rails. Fully assembled &Tubed Bonds modules to rails ° 9Lcw profile - Bonds devices to rails Single, universal size Sized to match modules , Single tool installation , Kit comes assembled Clear and black finish Clear and black finish a Mcunts in any direction ° Listed to UL 2703 F3ashiFvvt2 C,onduk Mount SlC3i3 ,L= Teti Hardwairs — - Flash and mount XR Mails Flas d mount conduit, - esign for=apidail Bond and attach XR Rails with superior waterproofing. �s ut, or junction boxes. attachment. to roof attachments. Twist on Cap eases-im all ^ Twist-on Cap eases install SPnt-ire. rail nnnnentinns T& Square Solt options Mind-driven rain, tested , Wind-driven rain tested Slot for vertical adjusting Nut uses 7/16" socket Mill and black finish Secures 3/an or 1"conduit Clear and black finish Assembled and lubricated - Design, Assistant NABCEiP Certified Tiraiining Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems.