HomeMy WebLinkAbout50914-Z *of SOUlyO!° Town of Southold
* * P.O. Box 1179
o� 53095 Main Rd
UNV Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 45917 Date: 01/30/2025
THIS CERTIFIES that the building GENERATOR
Location of Property: 220 Navy St Orient, NY 11957
See/Block/Lot: 26.-1-25
Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 05/29/2024
Pursuant to which Building Permit No. 50914 and dated: 07/09/2024
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
accessory generator as applied for.
The certificate is issued to: 220 Navy St Trust
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 50914 12/30/2024
PLUMBERS CERTIFICATION:
out orize ignature
o�SUFFoc,��o TOWN OF SOUTHOLD
BUILDING DEPARTMENT
y x TOWN CLERK'S OFFICE
o . SOUTHOLD, NY
a
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 50914 Date: 7/9/2024
Permission is hereby granted to:
220 Navy St Trust
79 W 12th St Apt 10A
New York, NY 10011
To: Install accessory standby generator at existing single family dwelling as applied for.
Maintain minimum 5 foot setback to property lines.
At premises located at:
220 Navy St, Orient
SCTM #473889
Sec/Block/Lot# 26.-1-25
Pursuant to application dated 6/29/2024 and approved by the Building Inspector.
To expire on 1/8/2026.
Fees:
ACCESSORY $125.00
ELECTRIC $100.00
CO-RESIDENTIAL $100.00
Total: $325.00
Building Inspector
o�%oF so�ryol
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 G Q
Southold,NY 11971-0959 �0
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: 220 Navy St Trust
Address: 220 Navy St City: Orient St: NY Zip: 11957
Building Permit#: 50914 Section: 26 Block: 1 Lot: 25
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: Electrician: Promaster Electric License No: 59226ME
SITE DETAILS
Office Use Only
Indoor rv— Basement 1— Service F Solar r
Outdoor 1st Floor F Pool r Spa r
Renovation r 2nd Floor F Hot Tub r Generator P-1
Survey 1— Attic I— Garage Battery Storage rLI
INVENTORY
Service 1 ph r Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph r Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors
Disconnect Switches 4'LED Exit Fixtures
Other Equipment: Generac Generator
Notes: Generator
Inspector Signature: X Date: December 30, 2024
Sean Devlin
Electrical Inspector sea n.devlin al_town.south old.ny.us
S.Devlin-Cert Electrical Compliance Form 2
oE So//T 2,e) � �T.
TOWN 'O SOUTHOLD BUILDI G--D�
cou 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING/STRAPPING [ ] FINAL
[ ] - FIREPLACE & CHIMNEY. [ ] FIRE SAFETY INSPECTION
[ . ] FIRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ : ] PRE C/O [ } RENTAL
-REMARKS:
G�A 1,A�
!!Ra eAA ttLe redlon
+kg za, e o
-�"Gcd Icn r�
CJ
DATE 1 Q / c " . INSPECTOR
OF SOUlyO�
# # TOWN••OF SOUTHOLD BUILDING DEPT.
cou � 631-765-1802
INSPECTION '
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
] FRAMING /STRAPPING &J(FINAL �j •
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT.CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ]- ELECTRICAL (FINAL)
[ ] CODE VIOLATION • [ ] PRE C/O [ ] RENTAL
REMARKS:
l a vk7tL_
'
8 (Gf,/ 47
DATE ANSPECTO4@
Of SOUTyo{o /1„ (�i/ y � L! V(��� .
�WN".OF SOUTHOLD BUILDING IpEPT.
courm��'` 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE.& CHIMNEY [ ] FIRE'SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O ( ]. RENTAL
REMARKS: tl
r_V4 a VC 16-�"Llzrj
� n Q
DATE P5P�ZZ INSPECTOR
FIELD INSPECTION REPORT DATE COMMENTS
C>
FOUNDATION (1ST) ...........
It
---------------------------------------
FOUNDATION (2ND)
O
---- --------
ROUGH FRAMING& . .....--
PLUMBING
INSULATION PER N.Y.
STATE ENERGY CODE
FINAL
.............
91.5
ADDITIONAL COMMENTS 9.3
1-1 - 214
< 0
om
X
..........
!�o`pguFFQ[�c02 TOWN OF SOUTHOLD—BUILDING DEPARTMENT
H =. Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 1 1971-0959
oy�o yo�� Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny,.gov
Date Received
APPLICATION FOR BUILDING PERMIT
i l h
For Office Use Only
I
PERMIT NO. �'� /� Building Inspector: MAY 2 9 2024 "v
P
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed. -'a��b'm ur'f—� 'J
Date:05/29/24
OWNER(S)OF PROPERTY:
Name:Susan Pelzer SCTM#1000-26-1-25
Project Address:220 Navy_ Street Orient NY 11957
Phone#:646-823-6934 Email:susan. elzer mail.com
_P _____@9_ _ - -
Mailing Address:220 Navy Street Orient NY 11957
CONTACT PERSON:
Name:AMP Architecture
Mailing Address:P.O Box 152 Mattituck NY 11952
Phone##631-603-9g92 Email:t@pperson a@amparchitect com
DESIGN PROFESSIONAL'INFORMATION:
Name:Anthony Portillo AMP Architecture
Mailing Address:P.O BOX 152 Mattituck NY 11952
Phone#:631-603-9092 Email:aportillo@amparchitect,com
CONTRACTOR INFORMATION:
Name:
Mailing Address:
Phone#: Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
D Other Generator Application $3,000
[Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes BNo
1
P ; PROPER TfY INFORMATION ¢ x
Existing use of property: Single Family Residence Intended use of property:Single Family Residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 NC this property? ❑Yes igNo IF YES,PROVIDE A COPY.
I�Chet k Box,;Afte r Readl n ;The owner/contractor/design professidnai Is responsible for all drainage and storm water lssuesas provided by
Chapter 236 of tholfow6tWde APPLICATION IS HEREBY MADE fo the BulldingYDepartment for the;issuance of a Bu!lding Permit pursuant to the Building Zi ne.,-
'ordm ance of the Town of Southold,Suffolk;County,New York and other appltr�abfe Laws,Ordinances or;Reguiatlons,,for the co`nstructlon of fiuildings
addigaris„alterations or�fo removalordemoiition asherein described The applicant agrees to comply virtth;all apptiwble Iaws,Fordinances,building codex` "r
",housing codeand regulations;and to admit authoraed inspectors on premises and in buildtng(sj for necessary inspectpns False statements made hereirt are;,r
unishable as a Class A misdemeanor ursuar�tto section Zi0 45koft e
P p h New York State Penallaw t �,r i <
Application Submitted By( 'nt name) 9 g
Authorized Agent ❑Owner
_.r _ _. _....._.... .. _w. _ _ _ _. �.
Signature of Applicant: Date: c�
STATE OF NEW YORK)
SS:
COUNTY OF )
vc_)(L;� 0 being duly sworn,deposes and says that(s)he is the applicant
(Name of individual ignin rcontract)above named,
(S)he is the
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of 20 1
No Pu
PROPERTY OWNER AUTHORIZATION DARCEEAUFENANGER
(Where the applicant is not the owner) NOTARY PUBLIC,STATE OF NEW YORK
Registration No.01A00019644
Qualified in Suffolk County
220 Navy Street, Orient Commission Expires January 9,2028
I,LoI i►� BWrara C—o►.,r'�-�—'( residing at
do hereby authorize AMP Architecture to apply on
my be alf to the Town of Southold Building Department for approval as described herein.
or,.Z9. ZLf
Owner's Signature Date
Print Owner's Name
2
BUILDING DEPARTMENT- Electrical Inspector
y� TOWN OF SOUTHOLD
o =` Town Hall Annex- 54375 Main Road - PO Box 1179
o • Southold, New York 11971-0959
4, Telephone (631) 765-1802 - FAX (631) 765-9502
iamesh ,southoldtownny.gov - sea ndA-southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All information Required) Date:
Company Name: ,Qo T-1 2 r
Electrician's Name: �D
License No.: �y� s 22 Elec. email: Q ,Y T,; ��
Elec. Phone No:^ 1 request an email copy of Certificate of Compliance
Elec. Address.: 12,ox,
JOB SITE INFORMATION (All Information Required)
Name: Z� /v�U ��, 7-P/S�-
Address: 2 D v 1,5
Cross Street:
Phone No.:
Bldg.Permit#: 50l /Lf email:
Tax Map District: 1000 Section: (p Block: Lot:
B ORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Square Footage:
Circle All That Apply:
Is job ready for inspection?: YES ❑ NO Rough In Final
Do you need a Temp Certificate?: YES ❑ NO Issued On
Temp Information: (All information required)
Service Size01 Ph 03 Ph Size: A # Meters Old Meter#
❑New Service Fire Reconnect[]Flood ReconnectOService ReconnectOUnderground[—]Overhead
# Underground Laterals 1 R2 D H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
�S�Ef01� BUILDING DEPARTMENT- Electrical Inspector
j�o CGy�� TOWN OF SOUTHOLD
Town Hall Annex - 54375 Main Road - PO Box 1179
o Southold, New York 11971-0959
�' �ao� Telephone (631) 765-1802 - FAX (631) 765-9502
lamesh southoldtownny.gov - seandCcb-southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name: �0I7 7-1 ' T f
Electrician's Name:
License No.: ,y� 22 Elec. email: ��-
Elec. Phone No: �e 2 41 request an email copy of Certificate of Compliance
Elec. Address.: ' 2 „� O,g_4 ;--
JOB SITE INFORMATION (All Information Required)
Name:Address:
Cross ,2 ® �-. ✓� ,ru
Cross Street:
Phone No.:
Bldg.Permit#: 5Dl L email:
Tax Map District: 1000 Section: P (p Block: Lot:
B ORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Square Footage: �
Circle All That Apply:
Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final
Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals D 1 2 D H Frame M Pole Work done on Service? D Y nN
Additional Information:
PAYMENT DUE WITH APPLICATION
PERMIT# Address:
Switches
Outlets
GFI's
Surface
Sconces
H H's
UC Lts Fridge HW POOL
Fans Mini Fr. W/D
Panel
Pump
Exhaust Oven Sump Heater
Trnsfmr
Smokes DW Generator Salt Gen.
Carbon Micro GrbDis
Water Bond
Lights
Heat Pucks ERV
Inst Hot DeHum Transfer HOT TUB/SPA
Disc
Combo Cooktop Minisplit Blower
AC AH Hood Blower
Service Amps Have Used
Sub Amps Have Used
Comments
S.C.T.M. N0. DISTRICT: 1000 SECTION: 26 BLOCK: 1 LOT(S):25
\C�TCH BASIN
NAVY STREET `I
EDGE OF PAVEMENT
CL-
p U.P.
Z
115.76' to -
191 .32' OU.P. N 8601812011 E o EL 5.6
t
EL 5.2
I�
N o
WELL ZONE AE(EL6) /IEl ZONE X
j N
o COVERED PORCH 61 .2'
�
25.4'
p - 2 STY FRA E :p
= °? DWELLING #220
FFL 6.6 LAND N/F OF
� 5.8'
,
5.3' CONSTANCE SCHRAFT
29.2
LAND N/F OF ' BILCO
6
MARIA REINECKE WELL
0.3'W 14.3'
SHOWER
PERGOLA A p
m
y {�
c� N 01
. m-� 8.3'
p 1 0.3' _ _
�P z o z 10.0,
7 w r
8.3' EL 6.3
Oo
SEPTIC N m
EL 6.5 M.H. 6.5'N 0.8'N
0.2'E
115.68'
S 84028'00" W I
LAND N/F OF I LAND N/F OF
DONALD ROSE I CAROLINE GREER NOLAN
REVOCABLE LVING TRUST
THE WATER SUPPLY, WELLS, DR YWEL L S AND CESSPOOL
FEMA MAP#36103CO068H LODATINSOR SHOWN
AREDFRO MFELDEROBSERVATIONS
AREA: 12,326.17 SQ.FT. or 0.28 ACRES ELEVATION DATUM: NAVD88
-------------------------
UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY
MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN
ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION
LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE.
THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE
NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS
AND/OR SUBSURFACE 5TRUE-TURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY
SURVEY OF:DESCRIBED PROPERTY ��0FNE�,y CERTIFIED TO: SUSAN PELZER;
MAP OF: A P�\N M 4/0�0
FILED:
Y °a Of
SITUATED AT:ORIENT r O
n �
TOWN oF:SOUTHOLD ems, "
050882 �4 KENNETH M WOYCHUK LAND SURVEYING, PLLC
SUFFOLK COUNTY, NEW YORK �� psi Professional Land Surveying and Design
P.O. Box 153 Aquebogue, New York 11931
FILE DATE: APRIL 10, 2021 PHONE (631)298-1588 FAX (631) 298-1588
# 220-89 SCALE: 1"=20' N.Y.S. LISC. NO. 050882 maintaining the records of Robert J. Hennessy & Kenneth M. Woychuk
APPROVED AS NOTED OCCUPANCY OR
DATE:jjoZ�B.P# USE IS UNLAWFUL
FEE' ,_& gY. WITHOUT CERTIFICATE
NOTIFY BUILDING DEPARTMENT AT OF OCCUPANCY
631-765-1802 8AM TO 4PM FOR THE
FOLLOWING INSPECTIONS:
1. FOUNDATION-TWO REQUIRED
FOR POURED CONCRETE
2. ROUGH-FRAMING&PLUMBING
3. INSULATION
4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. COMPLY WITH ALL CODES OF ALL CONSTRUCTION SHALL MEET THE NEW YORK STATE-&TOWN CODESAS REQUIRED AND CONDITIONS OF
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR $OUTHOLD TOWN ZBA .
DESIGN OR CONSTRUCTON ERRORS SOUTHHOLD TOWN PLANNING BOARD
SOUTHOIDTOWN TRUSTEES
N.YS.DEC
SOUTHOLD HPC
t
ELECffqMpjqtmm
RETAIN STORM WATER RUNOFF
PURSUANT TO CHAPTER 236
OF THE TOWN CODE.
GENERAC
GUARDIAN° SERIES
20/22/24 kW Residential Standby Generators
Air-Cooled Gas Engine
Standby Power Rating
INCLUDES:
G007038-1 G007039-1,G007038-3,G007039-3,Alumuu,m-Bisque)-20 kW GO Hz
• True Power" Electrical Technology G007012-2.G007043-2 G007042-3 G007043-3;Aluminum-Bisque)-22 k'dV 60 Hz
G007209-0 G007210-0:Aluminum-Risque)-24 kVv,30 Hz
• Two-line multilingual digital LCD Evolution'" controller
(English/Spanish/French/Portuguese)
• 200 amp service rated transfer switch available
• Electronic governor
• Standard Wi-FiO connectivity
• System status&maintenance interval LED indicators
• Sound attenuated enclosure ' � rX —'
• Flexible fuel line connector
• Natural gas or LP gas operation � 'GENERAC
f. ^„
• 5 Year limited warranty
• Listed and labeled by the Southwest Research Institute allowing 1
installation as close as 18 in(457 mm)to a structure.` '
'Must be located away from doors,windows,and fresh air intakes and in
accordance with local codes. C%0)usor c �L OShttps://assets.swri.org/tibraryIDirectoryOfListedProducts/ �j U1EHEST (�U.k LISTED
Constructionlndustry/973_OoC_204_13204-01-01_Rev9.pdt
Note:CETL or CUL certification only applies to unbundled units and units packaged
with limited circuit switches.Units packaged with the Smart Switch are ETL or UL
certified in the USA only.
FEATURES
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod-
Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI-
the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge
rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at r 1%.
O TRUE POWER" ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small-
allows confident operation of sensitive electronic equipment and micro-chip based est electronic component.
appliances,such as variable speed HVAC systems.
0 TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with
• PROTOTYPE TESTED NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC
• SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system
compatibility.
0 MOBILE LINO CONNECTIVITY:FREE with select Guardian Series Home standby ;D PWRVIEW'" TRANSFER SWITCH: The Generac PWRview Automatic Transfer
generators, Mobile Link Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con-
where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient
as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under
account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and
Mobile Link.users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator.Included with
model G007210-0.
w GENERAC Q@ @ GENERAC
PROMISE �,r TIMM PWR
Link
GENERAL
20/22/24 kW Features and Benefits
_ Engine
• Generac G-Force design Maximizes engine `breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil consumption and resulting in longer engine life.
• "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide.long engine life.
• Electronic ignition/spark advance These features combine to assure smooth,quick starting every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine
life.Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows for a smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes.
• UL 2200 listed For your safety.
Transfer Switch (if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 3R Can be installed inside or outside for maximum flexibility.
• Integrated load management technology Capability to manage additional loads for efficient power management.
• Remote mounting Mounts near an existing distribution panel for simple,low-cost installation.
PWRview Transfer Switch (if applicable)
• PWRview energy monitor Energy usage at-a-glance.
• Ability to view real-time energy consumption data Better understand the home's energy profile.
• PWRview mobile app Access daily energy intelligence and insights.
Evolution'" Controls
• AUTO/MANUAUOFF illuminated buttons. Selects the operating mode and provides easy,at-a-glance status indication in any condition.
• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences.
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations.
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home.
• Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds.
• Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute.
• Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
• Main line circuit breaker Protects generator from overload.
• Electronic governor Maintains constant 60 Hz frequency.
GENERAC-
20/22/24 kW Features and Benefits
Unit _
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding
winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access
to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries.
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure.
Installation System
• 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity (Wi-Fi equipped models only)
• Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for
complete peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
GENERAC-
20/22/24 kW Specifications
04 Generator
Model G007038-1 G007042-2 G007038-3 G007042-3 G007209-0
G007039-1 G007043-2 G007039-3 G007043-3 G007210-0
(20 kW) (22 kW) (20 kW) (22 kW) (24 kW)
Rated maximum continuous power capacity(LP) 20,000 Watts` 22,000 Walts' 20,000 Watts' 22,000 Watts' 24,000 Watts'
Rated maximum continuous power capacity(NG) 18.000 Watts' 19,500 Walls` 18.000 Walls' 19.500 Walls' 21,000 Watts'
Rated voltage 240•
Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5
of Total Harmonic Distortion Less than 5%
Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp
Phase 1
Number of rotor poles 2
Rated AC frequency 60 Hz
Power factor 1.0
Battery requirement(not included) 12 Volts,Group.26R'5140 CCA m nimu n or Group 35AGM 650 CC.,minimum .
Unit weight(Ib/kg) 448/203 466/211 436/198 445/202 455/206
Dimensions(L x:W x H)in dm, ,` 48 x 25"x 29/.121:9_z 63:5 x 73.7
Sound output in dB(A)at 23 It(7 m)with generator operating at normal load— 67 67 67 67 67
Sound ou_tput i-dB(A).at 23 It(7 m)with generator in Quiet-Test'"low-speed exercise mode" 55 57 55 57,. •57 ,
Exercise duration 5 min
Engine
Engine type GENERAC G-Force 1000 Series
Number of cylinders 2'
Displacement 999 cc
Cylinder block Aluminum Q cast iron sleeve.
Valve arrangement Overhead valve
Ignition system ; Solid_-state wCmagneto
Governor system Electronic
Compression,ratio
Starter 12 VDC
Oil capacity including#filter. APprox:.t_9 gt/_1.8 L -
Operating rpm 3.600
Fuel consumption.
Natural gas ft3/hr(m311r) 204(5 78) 2
1/?'Load 28(6 46) 164(4.64) 203(5.75) •.
Full toad •. 301t(8.52). 321(9:26) 287.(8.13) :.°306(8.66)
Li
gmd propane 1t3/hC(gal/hi)[Whr]
1/2'Load 87(2.37)[8.991`_ `92(2:53)[9.571. �B6,(2:36)1(8.95) 92'(2.53)[957].
= FuIlLoad 130(3.56)[13.48j:' `136(3.74)[14151 142(3:90)[14 77].
142(3.90)[74.77]
Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges 3.5-7 in water column(0.87-1.74 kPa)for NG.10-12 in water column(2.49 2.99 kPa)for LP
gas.For BTU content,multiply It3/hr x 2500(LP)or R3/hr x 1000(NG).For Megajoule content,multiply mVhr x 93.15(LP)or m3/hr x 37.26(NG).
Controls
Two-line plain text multilingual LCD Simple user interface for ease of operation.
Mode buttons:AUTO- _ . Automaticstk omutibty lzil ire.Weekly,f34eekly;or Monthly selectable ei erciser,
MANUAL Start with starter control,unit stays on.If utility fails•transfer to load takes place.
--OFF. Stbps Unit.,Power is rem_o`ved.Control and charger;still'operate..'
Ready to Run/Maintenance messages
Standard
Erigihe.runh M.,oursfndreatior
Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)
Utility Vol- a Loss/Return to Utildy_adlustable(brownouts6aing) From t140 171'V%.190,-216V
Future Set Capable Exerciser/Exercise Set Error warning Standard
Run/Atarm/Maintenance logs _ 50 events_46
Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration).
Starter lock out_ ;' -engagepnti _ _ ,r'engineh slipped.
Starter cannotre t 6 secafte as
Smart Battery Charger Standard
Cfiargec Fault/Missing AC viaining _
Standard
Low Battery/Battery Problem Protection and Battery Condition indication Standard
Automa(ic Voltage Regulation,witfr Over arid Und6Wtage Protection Standard. '
Under-Frequency/Overload/Stepper Overcurrent Protection Standard
Safety Fused/Fuse Problem Protection _ Standard.
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
'Standard:
Overcrank/Oversp"eed,(p72Fli)%rpm Sense`Lois_$hutdown''
High Engine Temperature Shutdown Standard
Interna[FaulUlncorrectWiria--r Iection _ Standard
Common external fault capability Standard
Fieldupgradable,firmware .- - ` .Stardard _
"Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying
emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514.IS03046 and DIN6271).'Maximum kilovolt amps and current are
subject to and limited by such factors as fuel BTU/megajoule content.ambient temperature,altitude.engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1.000It(304.8 m)above sea
level:and also will decrease approximately 1%for each 10'F(6'C)above 60'F(16'C).
GENERAC
afflnulffiew
20/22/24 kW Switch Options
Service Rated Automatic Transfer Switch Features Model G007039-1,0007039-3(20 kW)
• Intelligently manages up to four air conditioner loads with no additional hardware. G007043-2,G007043-3(22 kW)
Nofof poles
• Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) 200
with Smart Management Modules(SMMs). Voltage rating(VAC) 120/240,10
• Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor(fixed)*
• Rated for all classes of load,100%equipment rated,both'inductive and resistive. -Pick-up 30%
-Dropout 65%
• 2-pole,250 VAC contactors. Returr to lJtility' Approx.13.sec r
• Service equipment rated,dual Coil design. Exercises bi-weekly for 5 minutes* Standard
ETL or,UL listed,, Standard
• Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R
• Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit'b_a r protected 22,000_
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6
*Function of Evolution controller
Exercise can be set to weekly,bi-weekly,or monthly
Dimensions
200 Amps 120/240,1 a .1 ? -
Open Transition Service Rated
Height Width
Depth
H1 H2 W1 W2
in 26.8 30.1 10.5 13.5 6.9
cm 67.95 76.43 26.67 34.18 17.5 Hz Hi
r <a F:
Wire Ranges
Conductor Lug Neutral Lug Ground Lug f.'.
250 MCM-#6 350 MCM-46
-DEPTH- ._-------.W2
PWRview Automatic Transfer Switch Features Model 0007210-0(24 kW)
• Integrated PWRview monitor provides real-time energy usage data through PWRview app. No Current rating
roes
ting(amps) 200
• Intelligently manages up to four air conditioner loads with no additional hardware. Voltage rating(VAC) 120/240 i0
• Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(fixed)'
with Smart Management Modules(SMMs). -Pick-up 80%
-Dropout 65%
• Electrically operated,mechanically-held contacts for fast,clean connections. Return(aUtrhty Approx 13 sec
• Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes' Standard
• 2-pole,250 VAC contactors. Ehor I 'sled> Standard ,
Enclosure type NEMA 3R
• Service equipment rated,dual coil design. C rcud breaker protected 22000
• Rated for both aluminum and copper conductors. Lug range 250 MCM-#6
• Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller
Exercise can be set to weekly,bi-weekly,or monthly
• NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility.
• Heavy duty Generac Contactor is an ETL recognized device. -
Dimensions I
200 Amps 120/240,1 e
z
Open Transition Service Rated ;
H2 " HI
Height Width De th I
H1 H2 W1 W2 p
in 26.8 30.1 10.5 13.5 6.9 x
cm 67.95 76.43 26.67 34.18 17.5 }
Wire Ranges -DEPTH
Conductor Lug Neutral Lug Ground Lug
250 MCM-#6 350 MCM-#6 2/0-#14
GENERAL"
20/22/24 kW Available Accessories
_ Model# Product_ Description
G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for
use with all air-cooled standby product(excluding PowerPactO).
G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec-
essary for use with AGM-style batteries).
G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C).
G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where
heavy icing occurs.
G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be
Contact Kit needed.Not compatible with 50 amp pre-wired switches.
G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured
(Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion.
The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automatic standby generator(oil not included).
G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the
Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta-
tus alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec-
G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce
(100 amp) the overall size and cost of the system.
G007169-0-413 LTE Mobile Linker Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using
G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us-
Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,
users are taken care of before the next power outage.
G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured
appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit
contains four plugs,sufficient for use on a single air-cooled home standby generator.
Dimensions & PCs
Model UPC (25.1 mm 12,e mm
z5.,In] t4a o,n]
G007038-1 696471074185
G007038-3 696471074185
G007039-1 696471074192
G007039-3 696471074192
G007042-2 696471074208 727.2mm
t29.6 in]
G007042-3 696471074208
G007043-2 696471074215 91
G007043-3 696471074215 to 4 0 0
G007209-0 696471071511 —
G007210-0 696471078220 64emm zszmm
r25.5 in] r46.5 InI
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
GENE RAC Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com
womma—e®tee
IP2020 Generac Power Systems.Inc.All rights reserved.All specifications are subject to change without notice. Part No.A0000937814 Rev.B 07/30/2020