Loading...
HomeMy WebLinkAboutHPC BARNYE - 150 Baywater - 4 pages received 3-17-2025PROPERTY LOCATION:NEW GREEN HOUSE NEW EXTENSION COVERED PATIO E A NOTE: ALL PROPOSED OVERHANG TO MATCH ORIGINAL ROOF B NEW ROOF BELOW PITCH PITCH 4/12 C RIDGE BOARD 2 X 12 PITCH 4/12 PITCH 4/12 PITCH green design NEW ROOF BELOW PITCH 2/12 PROPOSED ROOF PLAN SCALE 1/4" = 1'-0" E NEW GREEN HOUSE D EXISTING BUILDING NEW MUDROOM ARCHITECT BRIAN O'CONNOR 130 N. WINDHORST AVENUE BETHPAGE, NY, 11714 (516) 476-8168 Croweng@aol.com hope drafting &expediting svc llc. BEATRIZ E FIRPO 125 CORTLAND STREET COPIAGUE, NY, 11726 (631)575-6254 hopedraftingsvc@gmail.com (917)251-7614 DRAWING NAME: PROPOSED ROOF PLUMBING WASTE DIAGRAM GAS RISER DIAGRAM STAMP A./E.: 4" EXISTING ROOF EXISTING ROOF VENT NEWMASTER BATHROOM EXISTING LAVATORY NEW ROOFVENT MUDROOM ROOF 2" LAVATORY LAVATORY WC 1 1/2" 1ST FL.C.O. 2"3" 4" EXISTING WASTE CONNECT TO PLUMBING WASTE DIAGRAM SCALE = NTS 4" DOB APPLICATION #: SHOWER W 2"1 1/2" 3" EXISTING CONNECT TOEXISTING 2"3" NEW WASTE 3" 2" LAVATORY 3" TUB C.O.SHOWER 2"3"2" SHOWER 3" 2ND FL.1ST FL. FROM EXISTING EXTEND EXISTING GAS LINE GAS RISER DIAGRAM SCALE = NTS DATE: 12/01/2024 DOB STAMP: A-107.00 PAGE No: 10 OF 20 WC 2" LAVATORY WC 2" 3/4"DRAWING No: STOVE NEW ROOF VENT 3" NEW ROOF VENT DATE: PITCH 4/12 RIDGE BOARD 2 X 12 NEW RAISED ROOF PITCH EXISTING ROOF NO CHANGE PITCH C NEW DOOR REVISIONS EXISTING DOOR PITCH 2/12 ROOF BELOW B SDCM 4 D 2A 3 75 CFM MH EXHAUST FAN (WHERE IS REQUIRED) EXISTING BUILDING EXISTING BRICK COVERED PATIO SOUTHOLD, NY 11971 150 BAYWATER AVE LEGEND: 1 EXISTING WALL TO REMAIN NE W G R E E N H O U S E NE W MU D R O O M EX I S T I N G B U I L D I N G EX I S T I N G CO V E R E D P A T I O @ 1 6 " O . C . ( T Y P . ) NE W 2 x 1 2 R A F T E R S @ 1 6 " O . C . ( T Y P . ) NE W 2 x 1 2 R A F T E R S @ 1 6 " O . C . ( T Y P . ) NE W 2 x 1 0 R A F T E R S @ 1 6 " O . C . ( T Y P . ) NE W 2 x 1 0 R A F T E R S @ 1 6 " O . C . ( T Y P . ) NE W 2 x 1 0 R A F T E R S @ 1 6 " O . C . ( T Y P . ) NE W 2 x 8 R A F T E R S 50 ' S E T B A C K PI T C H 8 / 1 2 ( V I F ) EX I S T I N G R O O F NO C H A N G E EX I S T I N G R O O F NO C H A N G E PI T C H 8 / 1 2 ( V I F ) NE W MU D R O O M EX I S T I N G B U I L D I N G EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED STUDS @ 16" O.C., 1/2" GYP. BD., 3 1/2 NEW EXTERIOR WALL CONSISTING 2 x 4 WOOD FIBER GLASS INSULATION WITH VAPOR BARRIER (R-13) BETWEEN WOOD STUDS PAPER AND VINYL SIDING FINISHED. 1/2" EXTERIOR PLYWOOD SHEATING, BUILDING PARTITION CONSISTING OF 2' X 4" WOOD NEW NON FIRE RATED (COMBUSTIBLE) DRYWALL STUDS WITH TOP AND BOTTOM WOOD GYPSUM BOARD ON EACH SIDE. RUNNERS AND ONE LAYER OF 5/8" THICK BSA CAL # 301-60-SM HARDWIRED SMOKE DETECTOR AND CARBON MONOXIDE DETECTING DEVICE. 01/24/2025 REVISION FOR HPC APPROVAL 03/15/2025 REVISION FOR HPC APPROVAL PROPERTY LOCATION: MATERIALS LIST SOUTHOLD, NY 11971 150 BAYWATER AVE LEGEND: 1 2 3 4 green design STAMP A./E.:DATE: PROPOSED ELEVATIONS ARCHITECT BRIAN O'CONNOR 130 N. WINDHORST AVENUE BETHPAGE, NY, 11714 (516) 476-8168 Croweng@aol.com hope drafting &expediting svc llc. BEATRIZ E FIRPO 125 CORTLAND STREET COPIAGUE, NY, 11726 (631)575-6254 hopedraftingsvc@gmail.com (917)251-7614 DRAWING NAME: REVISIONS SDCM DRAWING No: DATE: DOB APPLICATION #: 12/01/2024 DOB STAMP: A-109.00 PAGE No: 12 OF 20 EXISTING ROOF TO REMAIN AS IS C B A RIDGE EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED STUDS @ 16" O.C., 1/2" GYP. BD., 3 1/2 NEW EXTERIOR WALL CONSISTING 2 x 4 WOOD FIBER GLASS INSULATION WITH VAPOR BARRIER (R-13) BETWEEN WOOD STUDS (2) 2 x 8 HEADER MARVIN HISTORIC FLAT 6/4x3" TRIM WINDOW CEDAR SHINGLE UDHG2 2014 NOTE: UDHG2 2022 1ST FLOOR UDHG2 2022 KITCHENWINDOW EXISTING EXISTING EXISTING 1ST FLOOR EXISTING DOOR GRADE BRICK FOUNDATION CLADDING 14'-5"3'-0" EXISTING CEDAR SHINGLE TO REMAIN AS IS 27'-9" BASEMENT NEW MUDROOM C PROPOSED NORTH WEST ELEVATION SCALE 1/4" = 1'-0" B EXISTING BUILDING A EXISTING ROOF TO REMAIN AS IS RIDGE EXISTING ROOF TO REMAIN AS IS EXISTING CEDAR SHINGLE TO REMAIN AS IS EXIST.EXIST. EXISTING UCA3044EGRESS EXISTING ROOF TO REMAIN AS IS 2ND FLOOR (2) 2 x 8 HEADER (2) 2 x 8 HEADER NEW ROOF (2) 2 x 10 HEADER NEW 1ST FLOOR GRADE EXIST.EXIST. EXIST.EXIST. NEW EXISTING EXISTING NEW NEW NEW NEW NEW NEW NEW (2) 2 x 10 HEADER (2) 2 x 8 HEADER EXIST. (2) 2 x 8 HEADER NEW DOOR (2) 2 x 8 HEADER NEW (2) 2 x 8 HEADER NEW (2) 2 x 8 HEADER EXIST. EXIST. EXIST. EXIST.EXIST. (2) 2 x 8 HEADER (2) 2 x 8 HEADER (2) 2 x 8 HEADER 2ND FLOOR PAPER AND VINYL SIDING FINISHED. 1/2" EXTERIOR PLYWOOD SHEATING, BUILDING PARTITION CONSISTING OF 2' X 4" WOOD NEW NON FIRE RATED (COMBUSTIBLE) DRYWALL STUDS WITH TOP AND BOTTOM WOOD GYPSUM BOARD ON EACH SIDE. RUNNERS AND ONE LAYER OF 5/8" THICK BSA CAL # 301-60-SM HARDWIRED SMOKE DETECTOR AND CARBON MONOXIDE DETECTING DEVICE. 75 CFM MH EXHAUST FAN (WHERE IS REQUIRED) 24'-7" BASEMENT EXISTING BUILDING EXISTING BRICK COVERED PATIO EXISTING BUILDING PROPOSED SOUTH WEST ELEVATION SCALE 1/4" = 1'-0" D NEW EXTENSION COVERED PATIO NEW GREEN HOUSE E 27'-10"20'-1" 6' - 0 " 20 ' - 3 " 12 ' - 2 " 2' - 0 " 7' - 3 " 11 ' - 0 " 8' - 1 " 50 ' S E T B A C K 6' - 0 " 2' - 0 " 7' - 3 " 20 ' - 3 " 11 ' - 0 " 1' - 6 " 13 ' - 4 " ANTIQUE BRICK FACADE FOUNDATION CLADDING WOOD CEDAR 01/24/2025 REVISION FOR HPC APPROVAL 03/15/2025 REVISION FOR HPC APPROVAL D UDHG2 2418 HEADER (2) 2 x 8 NEW NEW UDHG2 2418 HEADER (2) 2 x 8 NEW RAISED ROOF E 50 ' S E T B A C K 3' - 0 " NEW UDHG2 2418 HEADER (2) 2 x 8 EXISTING ROOF TO REMAIN AS IS UP TO LINE OF SETBACK NEW ROOF BEYOND A B MATERIALS LIST EXISTING ROOF TO REMAIN AS IS 4" MIN. UDHG2 2014(2) 2 x 8 HEADER 1/4" TO 1/2" SPACING FOR DRAINAGE AND AIR FLOW FLAT 6/4x3" TRIM CEDAR SHINGLE SIDING 4" MIN. COPPER GUTTER STYLE SCALE 1/4" = 1'-0" TRIM TO SHINGLE DETAIL MARVIN HISTORIC CEDAR SHINGLE COPPER GUTTERS WINDOW FLAT 1X 6/4" TRIM NEW NEW NEW NEW NEW NEW NEW (2) 2 x 8 HEADER NEW UDHG2 2014 SDCM 1ST FLOOR GRADE BRICK FOUNDATION CLADDING 2'-7"9'-3"23'-4" BRICK FOUNDATION CLADDING 10'-0"REVISIONS BASEMENT A B EXISTING BUILDING EXISTING BRICK COVERED PATIO PROPOSED SOUTH EAST ELEVATION SCALE 1/4" = 1'-0" C NEW GREEN HOUSE NEW MUDROOM green design ARCHITECT BRIAN O'CONNOR 130 N. WINDHORST AVENUE BETHPAGE, NY, 11714 (516) 476-8168 Croweng@aol.com hope drafting & E MARVIN ULTIMATE WHITE 2/2 WINDOWS MARVIN HISTORIC WINDOW CEDAR SHINGLE COPPER GUTTERS WINDOWS SILL 8" MIN. ABOVE ROOF UDHG2 2418(2) 2 x 8 HEADER NEW NEW UDHG2 2418(2) 2 x 8 HEADER (2) 2 x 8 HEADER NEW UCA2418 EXIST. UCA3044EGRESS EXIST. (2) 2 x 8 HEADER (2) 2 x 8 HEADER D EXISTING ROOF TO REMAIN AS IS RIDGE EXIST. expediting svc llc. BEATRIZ E FIRPO 125 CORTLAND STREET COPIAGUE, NY, 11726 (631)575-6254 hopedraftingsvc@gmail.com (917)251-7614 DRAWING NAME: EXISTING PROPOSED ELEVATIONS (2) 2 x 10 HEADER NEW NEW NEW NEW (2) 2 x 10 HEADER (2) 2 x 12 HEADER NEW NEW NEW EXIST. NOTE: KITCHEN WINDOW (2) UCAP4040 EXISTING EXISTING 1ST FLOOR EXIST. BRICK FOUNDATION CLADDING 20'-1"17'-8"11'-1"23'-11" BASEMENT DATE: E NEW GREEN HOUSE NEW GREEN HOUSE 6/4x3" WHITE FLAT TRIM FOR WINDOWS AND DOORS TO MATCH EXISTING HISTORICAL DOB APPLICATION #:PROPOSED NORTH EAST ELEVATION SCALE 1/4" = 1'-0" D EXISTING BUILDING NEW MUDROOM 12/01/2024 DOB STAMP: EXIST.EXIST.GRADE DRAWING No: A-110.00 PAGE No: 13 OF 20 EXIST.STAMP A./E.:DATE: (2) 2 x 10 HEADER (2) 2 x 8 HEADER (2) 2 x 8 HEADER 2ND FLOOR EXIST.(2) 2 x 10 HEADER (2) 2 x 10 HEADER (2) 2 x 10 HEADER 2ND FLOOR 4 NEW 2 3 SOUTHOLD, NY 11971 150 BAYWATER AVE NEW RAISED ROOF RIDGE LEGEND: 1 C PROPERTY LOCATION: 3' - 0 " MI N . 1' - 6 " 13 ' - 4 " 3' - 0 " 3' - 0 " 50 ' S E T B A C K 50 ' S E T B A C K 6' - 0 " 6' - 0 " 2' - 0 " 7' - 6 " 20 ' - 6 " 11 ' - 0 " 2' - 0 " 7' - 3 " 20 ' - 3 " 11 ' - 0 " EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED STUDS @ 16" O.C., 1/2" GYP. BD., 3 1/2 NEW EXTERIOR WALL CONSISTING 2 x 4 WOOD FIBER GLASS INSULATION WITH VAPOR BARRIER (R-13) BETWEEN WOOD STUDS EXISTING DOOR NEW DOOR PAPER AND VINYL SIDING FINISHED. 1/2" EXTERIOR PLYWOOD SHEATING, BUILDING PARTITION CONSISTING OF 2' X 4" WOOD NEW NON FIRE RATED (COMBUSTIBLE) DRYWALL STUDS WITH TOP AND BOTTOM WOOD GYPSUM BOARD ON EACH SIDE. RUNNERS AND ONE LAYER OF 5/8" THICK BSA CAL # 301-60-SM HARDWIRED SMOKE DETECTOR AND CARBON MONOXIDE DETECTING DEVICE. 75 CFM MH EXHAUST FAN (WHERE IS REQUIRED) 01/24/2025 REVISION FOR HPC APPROVAL 03/15/2025 REVISION FOR HPC APPROVAL NEW UDHG2 2418 HEADER (2) 2 x 8 NEW WINDOW TO REPLACE DORMER EXISTING ROOF TO REMAIN AS IS UP TO LINE OF SETBACK NEW ROOF BEYOND PROPERTY LOCATION: SOUTHOLD, NY 11971 150 BAYWATER AVE D EXISTING ROOF TO REMAIN AS ISRIDGE EXISTING WALL TO REMAIN 2 Note: Replace Sheet Rock CeilingWith 1 HR Rated All Else to Remain UDHG2 2418 HEADER (2) 2 x 8 NEW NEW UDHG2 2418 HEADER (2) 2 x 8 EXISTING WALL TO BE REMOVED 3 STUDS @ 16" O.C., 1/2" GYP. BD., 3 1/2 NEW EXTERIOR WALL CONSISTING 2 x 4 WOOD FIBER GLASS INSULATION WITH VAPOR BARRIER (R-13) BETWEEN WOOD STUDS 4 SHELF Under 5'0"2ND FLOOR 3/8" Max. Stair Tread DepthVariation (tolerance)between Greatest andSmallest Treads within Smallesta Flight of Stairs 10" Min. Greatest EXISTING WOOD STAIR EXISTING ENTRY1ST FLOOR GRADE ELECTRIC PANEL NEW DOOR REVISIONS NOTE: BASEMENT FOUNDATION (TYP.)EXISTING CONC.EXIST. CONC. SLAB SPACE NOT FORSLEEPINGACCOMODATIONS UNFINISHED BASEMENT EXISTING BUILDING EXISTING BRICK COVERED PATIO EXISTING BUILDING BUILDING CROSS SECTION A-A SCALE 1/4" = 1'-0" D FP EXISTING STORAGE 1ST FLOOR NEW NEW NEW NEW NEW NEW SDCM Under 5'0"(2) 2 x 10 HEADER NEW NEW NEW NEW (2) 2 x 10 HEADER PAPER AND VINYL SIDING FINISHED. 1/2" EXTERIOR PLYWOOD SHEATING, BUILDING PARTITION CONSISTING OF 2' X 4" WOOD NEW NON FIRE RATED (COMBUSTIBLE) DRYWALL STUDS WITH TOP AND BOTTOM WOOD GYPSUM BOARD ON EACH SIDE. RUNNERS AND ONE LAYER OF 5/8" THICK BSA CAL # 301-60-SM HARDWIRED SMOKE DETECTOR AND CARBON MONOXIDE DETECTING DEVICE. 75 CFM MH EXHAUST FAN (WHERE IS REQUIRED) EXISTING DOOR NEW RAISED ROOF E LEGEND: 1 NEW EXTENSION COVERED PATIO NEW GREEN HOUSE E green design ARCHITECT BRIAN O'CONNOR 130 N. WINDHORST AVENUE BETHPAGE, NY, 11714 (516) 476-8168 Croweng@aol.com hope drafting & EXISTING ROOF TO REMAIN AS ISRIDGE Note: Replace Sheet Rock Ceiling With 1 HR Rated All Else to Remain Under 5'0" 2ND FLOOR CLOSET 3/8" Max. Stair Tread DepthVariation (tolerance)between Greatest andSmallest Treads within Smallesta Flight of Stairs 10" Min. Greatest EXISTING WOOD STAIR EXISTING ENTRY1ST FLOOR GRADE ELECTRIC PANEL FP EXISTING STORAGE NOT HEATED SPACE COVERED PATIO 1ST FLOOR FILLER 11 1/2" RCA MACHINE COMPACTED CRUSHED CONCRETE DRAWING No: 4" T H I C K M O N O L I T H I C POUR CONCRETE SLAB NEW 12" THICK CONC. FOUNDATION MIN. 4'-0" BELOW GRADE NOTE: BASEMENT FOUNDATION (TYP.)EXISTING CONC.EXIST. CONC.SLAB SPACE NOT FOR SLEEPINGACCOMODATIONS UNFINISHED BASEMENT DATE: 12/01/2024 DOB STAMP: EXISTING BUILDING EXISTING BRICK COVERED PATIO EXISTING BUILDING BUILDING CROSS SECTION B-B SCALE 1/4" = 1'-0" D NEW EXTENSION COVERED PATIO NEW GREEN HOUSE E DOB APPLICATION #: A-111.00 PAGE No: 14 OF 20 NEW NEW NEW NEW NEW NEW FLAT 6/4x3" TRIM COPPER GUTTERS E expediting svc llc. BEATRIZ E FIRPO 125 CORTLAND STREET COPIAGUE, NY, 11726 (631)575-6254 MARVIN HISTORIC WINDOW CEDAR SHINGLE GREEN HOUSE ROOF: 2X12 R.R. @ 16 O.C. COLLAR BEAMS EVERY OTHER RAFTER 1/3 DISTANCE FROM RIDGE 3/4 PLYWOOD WEATHER SHIELD ROOF GREENHOUSE TIMBERLAND ARCHITECTURAL ASPHALT ROOF TILE 15 LB FELT 8 INCH CLOSED CELL SPRAY FOAM 1 INCH RIGID R 7 FOAM NON CRUSHABLE. 5/8" 1 HR RATED GYP BOARD. COLLAR BEAMS CAN BE EXPOSED STAMP A./E.:DATE: hopedraftingsvc@gmail.com (917)251-7614 DRAWING NAME: BUILDING CROSS SECTION 6' - 0 " 20 ' - 3 " 12 ' - 2 " 2' - 0 " 7' - 3 " 11 ' - 0 " 8' - 1 " 2' - 0 " 6' - 0 " 12 ' - 2 " 7' - 3 " 11 ' - 0 " 20 ' - 3 " 8' - 1 " 50 ' S E T B A C K 50 ' S E T B A C K 50 ' S E T B A C K 50 ' S E T B A C K 3' - 0 " 4' - 0 " MI N . 1' - 6 " 13 ' - 4 " 4' - 0 " MI N . 1' - 6 " 13 ' - 4 " (2) 2 x 8 HEADER REVISIONS 01/24/2025 REVISION FOR HPC APPROVAL 03/15/2025 REVISION FOR HPC APPROVAL NEW D UDHG2 2418 HEADER (2) 2 x 8 NEW NEW UDHG2 2418 HEADER (2) 2 x 8 NEW RAISED ROOF NEW UDHG2 2418 HEADER (2) 2 x 8 EXISTING ROOF TO REMAIN AS IS UP TO LINE OF SETBACK NEW ROOF BEYOND EXISTING ROOF TO REMAIN AS IS UP TO LINE OF SETBACK NEW RAISED ROOF BEYOND