Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50248-Z
*of souryO!° Town of Southold * P.O. Box 1179 53095 Main Rd UPI Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45853 Date: 12/19/2024 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 315 Westphalia Rd Mattituck, NY 11952 Sec/Block/Lot: 141.-3-33 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/19/2023 Pursuant to which Building Permit No. 50248 and dated: 01/24/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: new windows and hvac system to existing commercial building as applied for. The certificate is issued to: 315 Westphalia LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50248 10/16/2024 PLUMBERS CERTIFICATION: i tAuedSignature o s�FFat/(. TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE N � Wvy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50248 Date: 1/24/2024 Permission is hereby granted to: Inland Homes Inc PO BOX 117 Mattituck, NY 11952 To: install new windows to existing commercial building as applied for. At premises located at: 315 Westphalia Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 141.-3-33 Pursuant to application dated 12/19/2023 and approved by the Building Inspector. To expire on 7/25/2025. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $300.00 CO-COMMERCIAL $100.00 Total: $400.00 Building Inspector SO(/T�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Southold,NY 11971-0959 Jamesh southoldtownny.gov COMM BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Inland Homes INC. Address: 315 Westphalia Road city:Mattituck st: New York zip: 11952 Building Permit#: 50248 section: 141 Block: 3 Lot: 33 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Russel G. Electric Electrician: License No: ME-62090 SITE DETAILS Office Use Only Residential Indoor X Basement X Service Commerical X Outdoor X 1st Floor X Pool New Renovation 2nd Floor X Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 46 Ceiling Fixtures 26 Bath Exhaust Fan 2 Service 3 ph Hot Water GFCI Recpt 15 Wall Fixtures 6 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 57 CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO $ Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 34 4'LED Exit Fixtures 4 Sump Pump Other Equipment: 4 emergancy lights, 1 electric mirror, 6 step lights Notes: AS BUILT Inspector Signature: Date: December 9, 2024 315 westphalia rd OF SO�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 97 1-0959 �� �o sean.devlin(&-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Inland Homes Inc. Address: 315 Westphalia-Rd city:Mattituck st: NY zip: 11952 Building Permit#: 50248 Section: 141 Block: 3 Lot: 33 WAS EXAMINED AND FOUND TO BE.IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Russel G Electric - License No: 62090ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Commerical X Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot.Water GFCI Recpt 2 Wall Fixtures Smoke Detectors Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 2 Switches 2 4'LED Exit Fixtures 11 Sump Pump El Other Equipment: Notes: HVAC Inspector Signature: Date: October 16, 2024 Copy r a0f SOUT,�°� # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 og INSPECTI-ON [ ] FOUNDATION' 1ST/ REBAR' [ ] ROUGH_PLBG. [ ] FOUNDATION.2ND [ ] ULATION/CAULKING ] FRAMING /STRAPPING [ FINAL Ol ll d-Ok6 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O - [ ] RENTAL REMARKS: WIVNJMA�? �v o Yv To�I v 1 DATE INSPECTOR hO��OF SO,Tyolo 4A /A # # TOWN OF SOUTHOLD BUILDING DEPT: holy ��o cou�m,� 631-765-1802 INSPECTION [ ] 'FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [. ] FIREPLACE.& CHIMNEY [ ] FIRE SAFETY"INSPECTION [ ] FIRE RESISTANT CONSTRUCTION - [ ] FIRE RESISTANT PENETRATION _ [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O , [ ] RENTAL REMARKS: J,�I.Aj L 44 o DATE INSPECTOR �pF SOUIH # # TOWN OF SOUTHOLD BUILDING DEPT. MuNn 631-765-1802 -INSPECTION [ ] FOUNDATION 1ST/REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING,. [ ] FRAMING/STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ - ] FIRE RESISTANT CONSTRUCTION [ .] FIRE RESISTANT..PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] -CODE VIOLATION [ ] PRE,C/O [ ] RENTAL MARKS: as smn f- 0 o r gook o s(a,Ao\ ou,4l cl vtie4s bto4t c4 o o,. PA &.O r I V%- bad n."As ro K n o r C o e n� o cA Pad Kj * Lot�-e-5 -rot- uj ci-4,e v -to er 0 en. nLA-4 i0f, ho use DATE ' �'�'� o �l � INSPECTOR OF SOUTyO6 316 W e,+�p hea�o� F SOUTHOLD..BUI ' DING DEPT. "^oum� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR. [ ] ROUGH PLBG. [ ]:. FOUNDATION 2ND ' [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL ] FIREPLACE-& CHIMNEY- [ ] 'FIRE SAFETY INSPECTION [ ] FIRE:RESISTANT'CONSTRUCTION [ ] FIRE RESISTANT.PENETRATION [ ] .ELECTRICAL (ROUGH) ' ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL h REMARKS: of T DATE o2 INSPECTOR ' DOUGLAS PEIX A R C H I T E C T P"` 18 March 2024 WINDOW ADDITIONS at 315 West Phalia Avenue, Mattituck, New York 11952 Southold Building Department Town Hall 54375 Route 25 P.O. Box1179 Southold, New York 11971 Building Permit# 50248 (issued 1/24/24) To whom it may concern: In reference to the new windows for 315 West Phalia Avenue, Mattituck 11952, 1 certify that the installation of the windows is code compliant and consistent with the approved drawings, P-1 and P-2. SincRED AR Co &3GLAS. 'J. �•la o4r •f:. DOUGL Q Lcc;Architect P.O. Box 1444- Mattituck,New York 11952 cell: 646,,643-9888 E-mail: info(a7dougpeix.com DOUGPEIX.COM 646.643.9888 DOUGPEIX@AOL.COM P.O.BOX 1444 MATTITUCK NEW YORK 1 1952 FIELD INSPECTION REPORT DATE COMMENTS G b FOUNDATION(1ST) pq y ------------------------------------ . FOUNDATION(2ND) QTA ROUGH FRAMING& y PLUMBING ' r INSULATION PER N.Y. H STATE ENERGY CODE LAAn 9n/t, Q FINAL ADDITIONAL,COMMENTS I -z5 Vz 0—" 4-66 v A )E)& S19A 1a4 Rr&l � etrvc' Ra�13,q jAcj4C gee 0 MO Z = rlb JD3110 rig e� �I k x b • H. Y G SFei,t�o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971- 0959 T_ele hone 631 765-1802 Fax 631 765-9502 h s //www.southoldtownn ov' • P f ) ) nP Y•g ' :• Date Received APPLICATION 'FOR BUILDING PERMIT r 1 t �'ttt .�i �'za t For Office Use Only . 7k 11 PERMIT NO. Building Inspector: `'� D:EC 1 9 2023 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an •"X•� ''�^•y37C Owner's Authorization form(Page 2)shall be completed. Date: �Z.• • 23 - OWNER(S)OF PROPERTY: Name: SCTM#1000- 4(, p .,TOa�, 33.: Din C Project Address: Phone-#:5- -- Email: ` 1 S( - Mailing Address: - CONTACT PERSON: - = Name_' �Ci�a C• ���e - - --._ - . --- - - --- - - -- Mailing Address: - Phone#: b3i- 45-43�® -- - - Email:PCMO0 f Moor _+,his"Com - - DESIGN PROFESSIONAL INFORMATION: V Name: _ Mailing Address: ' Phone?#�: ' I " ` Email: CONTRACTOR INFORMATION: Name: Mailing Address: fi _ Phone#:FJ EmailkA - Midi- DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration°❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes,❑.No Will excess fill be removed from premises? ❑Yes`❑No 1 y I PROPERTY INFORMATION' Existing use of property: - Intended use of.property: CAS Zone or use district in which premises is situated:: Are there any covenants and restrictions.with.respect to. . J c I this property? ❑Yes ONO IF YES, PROVIDE A COPY. 0 Check Box After,Reading: The.owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town'Code. APPLICATION IS HEREBY MADEto,the Building Department for the issuance•of a Building Permit pursuant to the Building Zone Ordinance of the Town of.Southold,Uffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal,or demolition as herein described.The applicant agrees to comply with.all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section210.45 of the New York State Penal Law. Application Submitted By(print na ►1'Y)CIOI C- Mn0 Ve. Q*uthorized Agent,., DOWner Signature of Applicant: - Date: l - 3 STATE OF NEW YORK) COUNTY OF 'F)k ' SS I ) 1�fYIC� C• munye being duly sworn, deposes and.says that(s)he is the applicant (Name of individual signing contra ct)`abovenarried, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the,said:work and to make andjile this application;that all statements contained in-this application are true to the best of his/her knowledge and belief;.and that the work will be performed in the manner set fortf in the.application file'therewith. Sworn before me this day of T)?C bC1hW .2023— Notary Pu lic KYLEE S DEFRESE PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC-STATE OF NEW YOR No.01 DE6420156 (Where the applicant is not the owner) Qualified in Suffolk County My Commission Expires.08-02-2025 I, �/1 n '`nc1 P,Y residirigat � Q (70fid, -AtV,e " Q tf,l Ny , do hereby authorize - to apply on my behalf to a Town of Sout ul in artment for approval as described herein.: 12 l8 2 40 ner s Sign ure Date Print Ow ts me 2 TAANE OCT. 8 2024 Product Data BUTILID IqG D'F2 . -Split System Cooling 4TTR3018N1000A, 4TTR3024N1000A 4TTR303ON1000A/B _ 4TTR3036N 1000A/B 4TTR3042 N 1000A: 4TTR3048N1000A 4TTR306ON1000A 11' FEE �1 R May 2023 22-1842-8Y-EN AN TECHNOLOGIES' TA4A/E' Outline Drawing B . i • SERVICE PANEL C ELECTRICAL AND REFRIGERANT ' COMPONENT CLEARANCES PER PREVAILING CODES i TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHERTWO SIDES UNRESTRICTED ELECTRICAL SERVICE K . ._ .PANEL .r:.. ... 22.2(718)DIA.HOLE A - LOW VOLTAGE 28.6(1,118)DIA.K.O.WITH 22.2(7/8)DIA.HOLE IN CONTROL - BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, "E„ H F 1:D.FEMALE BRAZE CONNECTION WITH 114"SAE FLARE PRESSURETAP FITTINGS Gv- L FIG.1 K.O.FOR ALTERNATE _ ELECTRICAL ROUTING From Dwg.D152898 GAS LINE 1/4TURN BALL SERVICE VALVE, •Da.. I.D.FEMALE BRAZED CONNECTION WITH.114"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H. J k 730 724 651 127 57. 194 . 38 457 4TTR3018N 2 (28-3/4) (28-1/2) (25-5/8) . 3/4 3/8 (5) (24/4) (7-5/8) (1-1/2) (18) 730 724 651 127 - 57 194 38 457 4TTR3024N 2 (28-3/4) (28-1/2) (25-5/8) 3/4 3/8 (5) (2-1/4) (7-5/8) (1-1/2) (18) 4FfR3030N 3 730 829 756 3/4 3/8 127 76 197 60 508 :(28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) ..(273/8) .(20) 47TR3036N 3, 730 829 756 3/4 3/8 127 76 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/.4) (2-3/8) . (20)- 41TR3042N 4. 741 946 870 7/8 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8). (3-1/4) (8-1/8) (2-3/4) (20) 4717113048N 4 741 946 _ 870 7/8 3/8 143 83 206. 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) _(2-3/4) (20) 4717113060N 4 943 946 870 7/8 3/8 152 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) 2 22-1842-BY-EN i' TA WF Product Specifications Model No.(a) 4TFR301BN1000A 4TTR3024N1000A 4TTR3030N1000A/B 4TTR3036N1000A/B POWER CONNS.-V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 12 14 14/17 16/18 BR.CIR.PROT.RTG.-MAX.(AMPS) 20 20 25 25/30 COMPRESSOR CLIMATUFF8-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS-LRAMPS 9-47.5 10.1-52 10.9-62.6/ 12.2-80.1/ 12.8-68 14.1-87.4 Outdoor Fan FLAMPS 0.85 0.85 0.64 0.64 Fan HP 1/8 1/8 1/8 1/8 Fan Dia(inches) 18.2 18.2 -23 23 Coil SPINE FINTM' SPINE FINT"' SPINE FINw SPINE FIN'*' Refrigerant R-410A 4 LBS.,11 OZ 4 LBS.,15 OZ 4 LBS.,11 OZ 5 LBS.,2 OZ VALVE CONNECTION SIZE-IN.O.D. 3/4 3/4 3/4 3/4 GAS VALVE CONNECTION SIZE-IN.O.D.LIQ 3/8 3/8 3/8' 3/8 LINE SIZE-IN.O.D.GAS(c) 3/4 3/4 3/4 3/4 LINE SIZE-IN.O.D.LIQ.(c), 3/8 3/8 3/8 3/8 Charge Spec.Subcooling 10OF 10°F 10°F 10°F Dimensions H x W X D Crated(IN.) 30.1 x 26.7 x 30 30.1 x 26.7 x 30 34 x 30.1 x 33 34 x 30.1 x 33 Weight-Shipping(lbs.) 153 153 183 189 Weight-Net(Ibs.) 133 133 156 161 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCTS01A TAYASCT501A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Service Valve Panel Cover - - - TAYSVPANL0032AA Refrigerant Lineset(d) (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated In accordance with N.E.C.Only use HACR circuit breakers or fuses. W Standard line lengths-60,Standard lift-60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0* (*denotes latest revision). (d) 25,30,35 and 50 foot linesets available.For a complete listing of lineset options available from equipment or supply stores,referto theTrane Residential and Light Commercial Product Handbook. 22-1842-BY-EN 3 i ® 7A4NF Product Specifications Model No.(a) 47TR3042N1000A 4TTR3048N1000A 47TR3060N1000A POWER CONNS.-V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 22 24 27 BR.CIR.PROT.RTG.-MAX.(AMPS) 35 40 45 COMPRESSOR CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS-LR AMPS 16.7-109 18.5-124 20.8-127.1 Outdoor Fan FL AMPS 1.05 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia(inches) 23 27.5 27.5 Coll SPINE FINTm SPINE FIN*"' SPINE FINTM Refrigerant R-410A 5 LBS.,5 OZ 5 LBS.,3 OZ 7 LBS.,30 OZ VALVE CONNECTION SIZE-IN.O.D.GAS 7/8 7/8 7/8 VALVE CONNECTION SIZE-IN.O.D.LIQ 3/8 3/8 3/8 LINE SIZE-IN.O.D.GAS(c) 7/8 7/8 7/8 LINE SIZE-IN.O.D.LIQ.(c) 3/8 3/8 3/8 Charge Spec.Subcooling 120F 10OF 10°F Dimensions H x W X D Crated(IN.) 34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight-Shipping(lbs.) 216 221 246 Weight-Net(lbs.) 184 189 211 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT301 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Service Valve Panel Cover TAYSVPANL0032AA TAYSVPANL0044AA TAYSVPANL0044AA Refrigerant Lineset(d) (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. cal Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (�) Standard line lengths-60,Standard lift-60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0* (*denotes latest revision). (d) 25,30,35 and 50 foot linesets available.For a complete listing of lineset options available from equipment or supply stores,refer to theTrane Residential and Light Commercial Product Handbook. 4 22-1842-8Y-E N 0 7R4W Product Specifications Sound Power Level Sound Power Level A-Weighted MODEL Sound Power Full Octave Sound Power(dB) Level[dB(A)] 63 125 250 500 1000 2000 4000 8000 Hz* Hz Hz Hz Hz Hz Hz Hz 4TTR3018N 71 74 71 65 68 67 63 56 50 4TTR3024N 71 74 71 65 68 67 63 56 50 4TTR3030N 71 73 73 72' 69 68 60 52 45 4TTR3036N 71 73 73 72 69 68 60 52 45 4TTR3042N 71 81 72 69 69 66 60 57 54 . 4TTR3048N 71 81 72 69 69 66 60 57 54 4TTR3060N 71 81 72 69 69 66 60 57 54 Note:Rated in accordance with AHRI Standard 270-2008*For Reference Only 22-1842-8Y-EN 5 T/PME' Accessory Description and Usage Anti-Short Cycle Timer—Solid state timing device that prevents compressor recycling until five(5)minutes have elapsed after satisfying call or power interruptions.Use in area with questionable power delivery,commercial applications,long lineset,etc. Evaporation Defrost Control —SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions.Used for low ambient cooling to 30OF with TXV. Rubber Isolators — Five(5)large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad.Use on any application where sound transmission needs to be minimized. Hard Start Kit—Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply,on long linesets,low ambient conditions,etc. Extreme Condition Mount Kit— Bracket kits to securely mount condensing unit to a frame or pad without removing any panels.Use in areas with'high winds,or on commercial roof tops,etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80eF DB,67eF WB air entering indoor coil,95eF DB`air entering outdoor coil. 2. High Temperature Heating 47eF DB,43eF WB air entering outdoor coil,70eF DB air entering indoor coil. 3. Low Temperature Heating 17eF DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions—(Noise rating numbers are determiend with the unit in cooling operations.)Standard Noise Rating number is at 95eF outdoor air. Model Nomenclature 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 Outdoor Units 4TWV0036A1 0 0 0 A A Refrigerant Type 2-R-22 4=R-410A TRANE Productlype W-Split Heat Pump T-Split Cooling Product Family V=Variable Speed M or B=Basic Z=Leadership-Two Stage A=Light Commercial X-Leadership L=Side Discharge R-Replacement/Retall Family SEER 3=13 6=16 0=20 4=14 8=18 5-15 9-19 Split System Connections 1.6 Tons 0=Brazed Nominal Capacity In OOOs of BTUs Major Design Modifications Power Supply 1=200.23011160 or.208-230/1160 3=200.23013160 4=460/3160 Secondary Function Minor Design Modifications Unit Parts Identifier 6 22-1842-8Y-EN TRINE Schematic Diagrams . Figure 1. O18N,O3ON,O36N,O42N&048N Models TO POWER SUPP-LY PER UNIT NAMEPLATE AND LOCAL CODES -- � 1 I --- -SEE PRODUCT DATA FOR—OPTIONAL.START——— — ACCESSORY— 10 J J m I C.S. I MS 6 CSR-ICSR , In Y I � I --------R D-------------i B R����----B K/B L------ MS 2 R '—.---------� -- CAPACITOR j E' L FAN PR tH R S'--- IOC MTR BK F C R cPR j THERMALLY —— _ R PROTECTED INTERNALLY. I I TYPICAL TYPICAL HPCO LPCO AIR HANDLER THERMOSTAT (777)'Q��� I LEGEND CF FAN CAPACITOR CN WIRE CONNECTOR Y I Y I - CPR.. COMPRESSOR— �J CR RUN CAPACITOR CS STARTING CAPACITOR BL _ L Y 0 CSR CAPACITOR SWITCHING RELAY ODT OUTDOOR THERMOSTAT NOTES Id2_ I HEAT HPCO HIGH PRESSURE CUTOUT SWITCH ' W3 CONTROLS I LPCO LOW PRESSURE CUTOUT SWITCH F_ (OPTIONAL) (REMOTE) MS COMPRESSOR MOTOR CONTACTOR I TNS ER ODO -B K.---tl --'r IOL I NTERNALMOVERLOAD PROTECTOR I ,-COLOR OF WIRE ODT. A o (OPTIONAL) I c�— '-- WI ---'--�—{ -- WI I BK/BL -B K•-------' I I I I ®COLOR OF MARKER BK BLAC ——————B K—————————— I J I I - - BL BLUE WHD WHI DTE OGR ORANGE G REEN BR BROWN YL YELLOW PR PURPLE PK PINK FOR CANADIAN INSTALLATIONS B ___+— — POUR INSTALLATIONS CANADIENNES B CAUTION; NOT SUITABLE FOR USE ON B L TNs SYSTEMS EXCEEDING 150V-TO-GROUND R D ATTENTION:NE CONVIENT PAS AUX — INSTALLATIONS DE PLUS DE 150 V A { LA TERRE TO POWER PER L SUPPLY LOCAL CODES PRINTED FROM D157362P05 REVB _J 22-1842-8Y-EN 7 . ® TRAIYE' Schematic Diagrams Figure 2. 018N,030N,036N,042N&048N Models .. /� LPCO HPCO BK OD E \ r f r-- B FAN . NOTES: KB' IOL I'. IF DDT-0 IS NOT USED.ADD JUMPER BETWEEN W2 A W3 AT AIR HANDLER. IF-USED,ODT-B - 'L�IIp-f-��pII. _ MUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. S R 1 Q THERMALLY 2, IF BIT IS NOT USED.ADD JUMPER BETWEEN WI 3 W2 AT AIN HANDLER. PROTECTED' ]. LOY VOLTAGE(24 VI FIELD WIRING MUST BE IB AWG MINIMUM. CPA / INTER NALLY 4. USE COPPER CONDUCTORS OXLYI LEGEND 24 V 1 F RELAY CONTACT (H.0) J FACTORY 41NE V WIRING RELAY CONTACT (N.C) -- 24 V FIELD -LINE V THERMISTOR IN RING -a� I ----- FIELD INSTALLED „i(0 TEMP ACTUATED SWITCH I - FACTORY WIRING `�2 ^ INTERNAL OVERLOAD PROTECTION Y MAGNETIC COIL � CAPACITOR I_ GROUND . r PRESSURE ACTUATED SWITCH JUNCTION RESISTER OR HEATING ELEMENT _ _ R f CAPACITOfl Of"„ WINDING "�D YD70R SEE PRODUCT DATA' B 0 WIRE NUT OR TOR OPT 1ORAL'START _ 1 ``•' B POL PLUO FEMALE HOUSIXO - O TERMINAL ..L,L.L WALE TERYINALSI NIT ACCEPPORY i2 TI } 'A '-) POE.PLUG MALE MOUSING ' - TRANSFORNER M ITEYALE TERMINALS) I i r_« -� ' � BNjBL TERMINAL BLOCK/BOARD I I 5 i i BL I CSR i I ------� -BK IBK YL/RD� I X2 I I NOTES 132 OA/YL (OPTIONAL) ----------I I i I (REMOT[.),I. IY I oor-B B ,ow I To---• [� I m-IF —J I m I I BK BFK I GR YL I . ------ III---- x� OD� i IIOPTIONALI' I i -- _-- BIKI. I � I _ — — ---- I -—-— -- ----� L TO.PONER PUPPET� PER PRINTED FROM D157362P05 REVB� UNIT.NAMEPLATES AND «« LOCAL CODES 8 22-1842-8Y-EN Y ' ® 7MWF Schematic Diagrams Figure 3. 024N Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I ^I o SEE PRODUCT DATA FOR OPTIONAL 11�J C= START KIT ACCESSORY Of I I CS > M I I CSR-1CSR Cif ------ R D-----------L B R is---B K/B L----- MS-2 RD 1 _ CAPACITOR 1 BK/BL _ 1 FOAN PR 'OR'OR --- S OLC 1 MTR BK F C H R _CPR I � THERMALLY R D En PROTECTED INTERNALLY LEGEND PCO TYP ICAL I TYP ICAL cF FAN CAPACITOR H F PCO LPCO I AIR HANDLER cN WI A,CONNECTOR THERMOSTAT I CPR- COMPRESSOR C�. I CR RUN RCAPAC I TOR C TA AT APA CIT OR O I CSRCAPCITONSWITCHIN G RELAY O F INDOOR FAN NPCOG UflEL MS YL H PRESSE CUTOUT SWITC H I I LPCO LOW PRESSURE CUTOUT SWITCH B L Y O IOL INTERNAL OVERLOAD PROTECTOR I SM SYSTEM ON-OFF SWITCH I I I MS COMPRESSOR MOTOR CONTACTOR NOTES 192 ODA OUTDOOR ANTICIPATOR -—-—- c�_— W 3 HEAT OFT OUTDOOR FAN THERMOSTAT (OPTIONAL) CONTROLS ODT B (REMOTE ODS OUTDOOR TEMPERATURE SENSOR 7� I X 2 I I I. DDT OUTDOOR THERMOSTAT �II-��I,—- 'T--� W2 I� - Wz TDL DIISCHARGEE LINE L THERMOSTAT D f— BK�--...JJJ I I I I I TNS TRANSFORMER ODT A (OPTIONAL) I c W I — — W I —� _,--COLOR OF WIRE BK----- i � I BK/BL I I I —-COLOR OF NARNER GN GLACN III) OR ORANGE —— G BR GROWN YL YELLOW PR PURPLE I I PN PINN LT GL LIGHT GLUE B L B FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUT ON: NOT R 24V— -R D Tn 1 R USE ON rA STEMS EXCEED UI NG SUITABLE OV OTO GROUND �/ I CONVIENT PAS AU1(TALLATIONS DE PLUS DE 150 V A r TERRE TO POWER SUPPLY J =--��� i _ — 1 I PER LOCAL CODES —— • PRINTED FROM D157362P08 REVA 22-1842-8Y-EN 9 • Y ® � Schematic Diagrams Figure 4. 024N Models NOTES: /-�� LPCO HPCO BK OD I. IS NOT USED. ADD JUMPER BETWEEN C IOL\ � ��QTQ� PR FAN W &W3 2 A W3 AT AIR HANDLER. IF USED, ODT-B BKBL 1 'LEI b II�I�Q IIIJ BR MTR MUST BE MOUNTED OR REMOTE OF CONTROL BOX IN D S R c THERMALLY AN APPROVED WEATHER PROOF ENCLOSURE. TED'/ Y ` 2. IF ODT-A IS NOT USED. ADD JUMPER BETWEEN CPR vgoTEC _ 0 INTERNALLY _ WI A W2 AT AIR HANDLER. ------- 3. LOW VOLTAGE 124 VI FIELD WIRING MUST BE IR AWG MIN. ' I I LEGEND 24 V FACTORY I I LINE 4}WIRING —— 24 Y l FIELD LINE y�WIRING FIELD INSTALLED ' FACTORY WIRING I CAPACITOR MAGNETIC COIL RD/ E �.{N 0R ' GROUND I - --- 'Y • JUNCTION 1 •1 I '�+ _BR 1 CAPACITOR 1 0 WIRE NUT OR I T2 TI + 1 s 0 TERMINAL F' Y TRANSFORMER 1 1 r1J FUSE I I BL I ❑ TERMINAL BLOCK/BOARD ' I 'L2 _M S LI }J RELAY CONTACT 1N.01 RELAY CONTACT IN.CI 'SEE PRODUCT 1 DATA FOR I '1 1 THERMISTOR OPTIONAL START I 1 1 I NIT ACLESSORj-_1 1 1 ' Cri �FII C TEMP ACTUATED SWITCH i I---�--• - --------- -- -*--------------a `o I 1 o Cry INTERNAL OVERLOAD PROTECTION I I BKBL I r l 5 i I PRESSURE ACTUATED SNITCH I I I 2 I 1 YL/RD I 1 RESISTER OR HEATING ELEMENT ' ; I I CSRj i 1 OR/YL3 I I — —1 J---- Cr' 0 MOTOR WINDING - -Y--- -" -1 I MAL EPOL L TE RMI Np�S7H0USINC ®v . UG G I I � A POL(FEMALEPL TE RMIMALE NALSIHOUSIN I- --' I1Q'K2 I � NOTES 182 _ I i I I _ ( OPTIOIALI �B IT 'REMOTE, I BK I L----�K J 1i 0" I loPToxALBKI I I - ---- -----I 1 i i -------- TO POWER SUPPLY PER 1__-=�URIT NAMEPLATES AND PRINTED FROM D157362P LGCAL 08 REVA CODES ' I 10 22-1842-8Y-EN 0 7RWF Schematic Diagrams Figure 5. 060N Models I TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL 'CODES I 1 SEE PRODUCT DATA n FOR O13iPTIONAL START NIT ACCESSORYCr J J i__C S_ I [O cc MS-1 8R CSR-I CSR I MS 2m 1 RD® X -8K/BL OD CAPACITOR FAN BR PR F JC H OR JOR COLMTRBKL:LHn CPR I THERMALLY R D _ I Ln PROTECTED INTERNALLY �------ -I LEGEND TYPICAL TYPICAL HPCO LPCO CF FA AIR R HANDLER THERMOSTAT ' N CAPACITOR CN WIRE CONNECTOR CPR COMPRESSOR J O ' CS RUN CAPACITOR J r O y I C STARTING CAPACITOR MS Y I Y I —————_ ——_O I CSR CAPACITOR SWITCHING RELAY ODT OUTDOOR THERMOSTAT BL HPCO HIGH PRESSURE CUTOUT SWITCH I ' LPCO LOW PRESSURE CUTOUT SWITCH NOTES IA2 r— MS COMPRESSOR MOTOR CONTACTOR __ 0 HEAT I TNS TRANSFORMER _ (OPTIONAL) I — 3 CONTROLS ' I IOL INTERNAL OVERLOAD PROTECTOR rY -- 1r �-I Wp SK,-COLOR OF HIRE COLOR OF MARKER X ' UK BLACK RD RED OR ORANGE ODT—AA l// (OPTIONAL) — NII ---�—�—I --- V�I BL BLUE WH WHITE OR GREEN r o�o- B K�� I R BROWN YL YELLOW PR PURPLE II I PK PINK B K X L_—_—_J FOR CAN AD' AN INSTALLATIONS POUR INSTALLATIONS CANADIENNES I O CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V-TO-GROUND ATTENTION:NE CONVIENT PAS AU% INSTALLATIONS DE PLUS DE 150 V I A ———i— — I LA TERRE BL 8 TNS I - R ——I—I—R D—O I TO POWER SUPPLY =_ �1 PER LOCAL CODES ———�—� I __-_-__J PRINTED FROM D160439POI REVA 22-1842-8Y-EN T T 0 /RAAF X Schematic Diagrams Figure 6. 060N Models xolFs: LPCO HPCO I. F OOT-U IS NOT U.B.ADD JUYPEfl.—IS.WR L WS A7 AIR N-11", IF USED,00T-B /' 0 \ r r FFyy..— B K OD MUST BE MOUNTED 9EM07E OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. I T I T P R FAN BK/BLVIR TOIL ` IL�II p+ll D.IF 00T-A IE HIT USED.ADD JYYPLR UEIWE[Y YI L R Al AIR HANDLES. / OR — B R MTR 1.LOW VOLTAGC I21 VI FIELD LO MIR IXG XUSI BC IB AW MIY IYUM. A.USC COPPER CON.0070R5 OxL TI AD R THERMALLY J PROTECTED �A o INTERNALLY LEGEND I ----------- — - - ------------� 21 Y l fACTOflT -If RELAY CONTACT IX.01 I fl IINE S1■IRIYG RELAY CONTACT IN.CI —— 21 Y FIElO LIME MIRING y.K.M 1N[IYILIOR I —X—24 Y FIELD INSTALLED \�-:- TFYP-GATE.SWITCH _x�LINE V}FACTORY WIRING INTERVAL OVERLOAD PROTECTION MAGNETIC COIL a 1_ GROUND d C IRESSUAE UTUA71D SWITCH FO JUNCTION -YVV-RES ISi[R ONHEATING ELEMENT Ll -3P- CAPACITOR CAPACITOR T`"-b I010R WIAGING 0 ■IAE RUT OR IOL.PIUG ANAL[HOUSING RD �P-�I����R OR CONNECTOR �IY.LIF fERN I YAL iI C �yV 0 TERMINAL IOL.PLUG HALT XOUSINO I Annan/ IF[YAL[i[IY IYALSI x I M„vT TRANSFORMER 'SEE PRODUCT DATA F B R ' TERMINAL BLOCK/BOARD I FOR OPTIONAL START KIT ACCESSORY_ _ IT2 TI I II. II BL IL2 -M P.. BKL 5 Rj j LI I'' x x ' x x BK I Cs ---- BK I I---`--------I YL/RD=�D I X2 I xor[s Isz _ OR/YL I OPTIO ------- I �_--IREMOTE1 TEI I / I i ODT-B I Q. ---- � X BK--- BKJ GR/YL I X °D 4� (/�1Y X � 1 —J 1 IOPTIONALI x BK ___________ I I I _ _____ _ _ _ _ _ — PRINTED FROM D160439P01 REVA L — — -1T0 POWER SUPPLY PER J}UNIT NAMEPLATES AND LOCAL CODES 12 22-1842-8Y-EN 0 TAWF* Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit,ten(10)feet of tested connecting line,and the smallest rated indoor evaporative coil match.This unit is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistant powder paint finish.The corner panels are prepainted.All panels are subjected to our 1,000 hour salt spray test. Refrigerant Controls Refrigeration system controls include condenser fan,compressor contactor and low and high pressure switches.A factory supplied,field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection.Other features include:Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured,this system has a cooling capacity to 55°F.The addition of an evaporator defrost control permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats—Cooling only and heat/cooling(manual and automatic change over).Sub-base to match thermostat and locking thermostat cover. 22-1842-8Y-EN 13 TRAMV Trane - by Trane Technologies (NYSE: TT), a global innovator-' creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. I Unitary Small AC j AHRI Standard 2101240 c L us LISTED The AHRI Certified mark indicates Trane U.S.Inc.participation in the AHRI Certification program.For verification of individual certified products,go.to.ahridirectory, org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 22-1842-8Y-EN 24May2023 Supersedes 22-1842-SX-EN (February 2023) - ©2023 Trane ' L • QFFICE OO F PATRICIA C. Ni00O�R 51020 MAIN ROAD t �I � j SOUTHOLD NY 11971 j� 631.765.43.30 , '- MAR 2 1 2024 O. Building Department PATRICIA C..MOORE(BY:_KD_) uB1 CT: Building Permit #50248 ATE: March 21, 2024 COMMENT: . Enclosed please,find a letter from the architect stating that the installation of windows is code compliant and consistent with the approved drawings. Pontino, Susan From: Kevin Keyser <kxkl030@gmail.com> Sent: Wednesday, September 25, 2024 10:41 AM To: Pontino, Susan Subject: electrician number and name of company Hello Susan, I. have the company name.The electrician and I have his ID number. His number is 62090.The name of the company is Russell G. Electric.for Suffolk MA. Rd Massapequa 11758.OK, if there's anything else that you need for me, please reach out. Kevin Keyser. 315 Westfalia Rd. Mattituck, NY.952. Can you please tell me that you received this today?Thank you. kevin x keyser ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. � 1 �Suff�t,�i IV DING DEPARTMENT- Electrical Inspector S E P 2 4 2024 I TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 s BIDING�E Southold, New York 11971-0959 4,� 0i TO' F SOS r y phone (631) 765-1802 - FAX (631) 765-9502 �` lames (a-southoldtownny.gov — seand(@,southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: -5e c-,-, Electrician's Name: License No.: 0 q(9 Elec. email: Elec. Phone No: ❑I rpquest an email copy of Certificate of Compliance. Elec. Address.: � �� l/j SSGL cPG� l7 JOB SITE INFORMATION (All Information Required) Name: Address: �`� �c Cross Street: Phone No.: '6 � BIdg.Permit#: C�� email: Tax Map District: 1000 Section: Block: �j Lot: 3 BRIEF DESCRIPTION OF WORK. INCLUDE SQUARE FOOTAGE (Please Print Clearly): rl C'11 Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 FJ2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ��{� �I�3 � FFO(,I- � U DING DEPARTMENT- Electrical Inspector SEP 24 20211. TOWN OF SOUTHOLD Town Hall Annex.= 54375-Main;Road - PO.Box`l 179 Southold, New York 11971-0959 DNISOS &elephone (631) 765-1802 -;,FAX (631) 765-9502 ' {L dames i(a.southoldtownny.gov — seand(c-Dsoutholdtowriny g v i APPLICATION FOR ELECTRICAL INSPECTION ' ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: 5'5e C , -e c4y) Electrician's Name: V � L� License No.: � Elec: email: Elec. Phone No: ❑I rpquest an email copy of Certificate of Compliance Elec. Address.: l 76F JOB SITE INFORMATION (All Information Required) Name: \ ` :&tctO A �o �2 �. Address: ` - Cross Street: Phone No.: Bldg.Permit email: Tax Map District: 1000 Section: Block: rj Lot: BRIEF DESCRIPTION OF WORK. INCLU Q ARE FOOTAGE (Please Print Clearly): 0 Square Footage: Circle All That Apply: Is job ready for inspection?: YES [] NO Rough In Final Do you need a Temp Certificate?: YES ❑ NO Issued On Temp Information: (All information required) Service Size 1 Ph F—]3 Ph Size: A # Meters Old Meter# ❑New Service0 Fire Reconnect[]Flood Reconnect Oservice Reconnect OUnderground QOverhead # Underground Laterals R 1 R2 H Frame Pole. Work done on Service? Y R N Additional Information: PAYMENT DUE WITH APPLICATION IG� �1 PERMIT# Ad ress: Switches LVl 6�� Outlets. + o� G F I's Surface `k q0 Sconces H H s UC Lts Fridge I HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW I Generator Salt Gen. Carbon Micro �. GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo 1 Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments Etedt 6 G r 6 OP � JOSHUA R. WICKS P.L.S. SURVEYED BY:J.R.W. DRAWN BY:D.T.O. JOB NO.:JRWa3-O3a5 P.O. BOX 595 Center Moriches, N.Y. 11994 JoshuaRWlcke®gmaiLcom /881-405-8108 GRAPHIC SCALE —ee�— TAX LOT 34 \ o a(sal Z po) 3(6R7 eB.rs• RIGHT OF WAY �^ N 45e05'00" E 77.83' \� SU or ppopfpTy ,� sminrE GMVO. Amrnna,row 0�5"an siffaK COLW,,NEW YOW F o a_ .`uffdk Canty fax Map No,: s I ASIMTp�T 1000-141,00-03,00-033,000 a � VA1E 9MYEV:10/W 2025 HSCALEi 1"=20' Y (� CONG LET.WALL 't 56 ca(c. nAr � L/l1� Ba7 ov 0 I $ \aN La 1� 2 STY. FR. BDG. \� p C).O Q S 45005'00" W 105.00' LONG ISLAND RAILROAD 60 ZGAREA 0.44 ACRES) oF NEw, r•'J�oy�uP R. GUARANTEED TO. KEVIN Z KETSER EMINENT ABSTRACT, INC. WESTCOR LAND TITLE INSURANCE COMPANY MEADOWBROOK FINANCIAL MORTGAGE BANKERS CORP. ISAOA ATINA l��f N.05j0tih ysFO LAND 0)UNAUTNOWZED ALTEWION OR ADOIRON TO 1HI5 SURVEY NAP BEWNG A LICENSED VVO SURVEYOR'S SEAL 6 A VWIATWN OF S7•:CiION 7N9.SUB-0 ON 2.OF NE1/NOW SLATE EDUCATION LAW.(2)ONLY BOUNDARY SVRVET NAPS WRH WE SURVEYORS ENWSSED SEAL ARE CENOBff TRUE AND CORREC COPIES OF WE SURVEYOR'S G NAL WOW(AND OPNWN(�CEHIIWCADONS ON THIS BOUNDARY SURVEY YAP SCNRY 1HT THE NAP WAS PREPARED IN ACCORDANCE NOW THE CURRENT EDSLNG COOS OF RUCRCE FOR—SU(NEYS ADOPTED BY THE NEW nRK 5T TE ASBDCIARON OF PROF®ON&LARD SURVEYORS,NC WE CERTYLGRON R MM TO L'FRSDNS FOR WHOM THE BOUNDARY SURVEY YAP R PREPARED.TO THE LTRE CEVPANY,TO THE GDVENNENtX AGENCY,A40 TO THE—M.INSRRIIRDN USIED ON TH5 BOUNDARY SURVEY NAP.(4)THE OEHT6TCTION$HEREN ARE NOT TRANSFERABLE(5)THE LOGDON OF UNDERGROUND INPROYBAENS OR ENCROACHMENTS ATE NOT ALWAYS KNOWN AND OFTEN NMT BE ESONATED. 6 ANY UNDERGROUND INPRP ENR OR ENCHOACRNENS D1OST OR ARE SHOWN,THE INPROVENENS OR ENCROXHNENTS ARE NOT COVEED BY THIS SURVEY.(6)WE OFFSET(OR DINENSONS)SHORN HEREON MN THE SRNCNRES TO WE PROPERLY LRES ARE FOR A SPEIRC PURPOSE AND USE NRD THEREFORE ARE NOT INTE 0 TO CUWE WE ERECTION OF FENCES.RETNNING Y! 5.PD0..5,PATWS PLWTING AREAS.ADDITIONS TO BWW-I S,AND ANY ODIER TTPE OF CDNBTRUCRDN.(7)PROPEWY CORNER NONMENS WERE NOT SET a PARE OF TH6 SURVEY.(6)TN6 SURVEY WAS PETDORNED VADR A TWNaE W ROBORC TOTAL SIATDN. 9 THE E%ISTFNCE OF-OF WAYS..OH EASEAIENS OF RECORD'F ANY,NOT SHOWN ARE NOT GIARNJI®. HAMPT-2 OP ID:VM CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDmYY) 02/10/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: MICHAEL VENTURA BADGE AGENCY,INC. PHONE 516-676-0070 FAX No:516-676-0258 1000 Woodbury Rd,Suite 207 aC No Ext Woodbury,NY 11797 E-MAIL MICHAEL VENTURA ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Utica Mutual INSURED Hamptons Silverleaf Landscaping,Inc. INSURERB:STATE INSURANCE FUND 00640 Kevin Keyser 1356 Grand Ave. INSURER C Mattituck,NY 11952 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE 9kDDL U POLICY EPF POLICY EXP LIMITS LTR INSD WVD POLICY NUMBER MMIDD MMlDD/YYYY A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE FRI OCCUR X ART 5074759 04 08/24/2023 08/24/2024 PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,00 PPOLICY JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: AUTOMOBILE LIABILITY Ee acl NED identSINGLE LIMIT $ c ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER B ANY PROPRIETOR/PARTNER/EXECUTIVE YIN N 12370 133-7 08/27/2023 08/27/2024 E.L.EACH ACCIDENT $ 100,000 OFFICER/MEMBER EXCLUDED? �N/A 1 OO,000 (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under E.L.DISEASE-POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS below DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) CERTIFICATE HOLDER CANCELLATION SOUTHLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold PO Box 1179 53095 Rte 25 AUTHORIZED REPRESENTATIVE Southold,NY 11971 ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD Nunemaker, Amanda From: Patricia C. Moore <pcmoore@ moo reattys.com> Sent: Tuesday,January 23, 2024 2:24 PM To: Nunemaker,Amanda Cc: Kevin Keyser;doug@dougpeix.com Subject: Re: 315 Westphalia Rd I was sent the following info hefirsfl ,win,d_ows__a're setieslAO�Anders en windo ws,With e c w a U The` fidtorywindows_are-400 A senindoth LU-Fac-t oFracotfo-0r:o2f8-0.:3-1.,; Do they need`documentatidnn this? Pat Patricia C. Moore, Es a. P.0 E fA.M U BE SURE TO GOPY MY ASSISTANTS betsv@mooreattvs.corn and kvlee@mooreattvs.com --------------------------- Mailing & Physical Address: Moore Law Offices 51020 Main Road William D. Moore, Esq. Southold NY 11971 631.765.4663 Fax Number: Patricia C. Moore, Esq. 631.765.4643 631.765.4330 www.mooreattVs.com On Tue,Jan 23, 2024 at 10:49 AM Nunemaker,Amanda <Amanda.Nunemaker@town.southold.nv.us>wrote: Hi Pat, I have reviewed the application for the new windows on the commercial building. The plans look fine, but I do not have any indication of the U-factor of the windows or any series information. Please forward the specs when you can. Thank you. Amanda Nunemaker Building Permits Examiner Southold Town Hall Building Department 631-765-1802 - 1 . mAN DERSENT" . W I N D O W S & . DOOR S CREATED DATE SOLD BY: SOLD TO: 11/11/2023 %RIVERNFAD Benjamin Blados-Millwork Sales BUILDING SUPPLY Mobile:631-506-1454 LATEST UPDATE Bupd 81nMat Build BbBer. bblados@rbscorp.com 11/13/2023 250 David Court Calverton,NY 11933 OWNER Benjamin Blados Abbreviated Quote Report- Customer Pricing QUOTE NAME PROJECT NAMEQUOTE NUMBER - CUSTOMER PO# TRADE ID+��� Hampton Silver.Leaf--Westphalia Hampton Silver Leaf- 4957473 Project Westphalia Project ORDER NOTES: DELIVERY NOTES: ~� Item QtC Operation , Location Unit Price Ext. Price 100. 6 Vent None Assigned $549.40 $3,296.40 RO Size=32"x32" Unit Size=31 1/2"x 31 1/2" AX281;Unit,`400 Series Awning, Installation Flange,White Exterior Frame, Pine w/Unfinished Interior Frame;'Vent; Dual Pane Low-E4 Standard Series Argon Fill Traditional Trim.Stop Profile Stainless Glass/Grille Spacer,Traditional Folding, White, White,-Full Screen,Aluminum 31.6� -RD-32 Hardware: PSA Traditional Folding White PN:1521039 Insect Screen 1:400 Series Awning,AX281 Full Screen Aluminum White PN:1586373 n �n Unit# U_Factor _SHGC-� ENERGY STAR �J V Al 0.28 0.32 NO 4 T.oa�a;?o;S C1 �c� Quote#: 4957473 Print Date: 11/13/2023 2:21:51 PM UTC All Images Viewed from Exterior Page 1 of 2 I SUB-TOTAL: $3,296.40 FREIGHT: $0.00 LABOR: $0.00 TAX: $284.31 TOTAL: $3,580.71 CUSTOMER SIGNATURE DATE "All graphics as viewed from the exterior.'*Rough opening dimensions are minimums and may need to be increased.to allow for use of.building wraps or flashings or sill panning or brackets or fasteners or other items. Thank you for choosing Andersen Windows & Doors Quote#: 4957473 Print Date: 11/13/2023 2:21:51 PM UTC All Images Viewed from Exterior Page 2 of 2 U.S. ..Canada . ENERGYSTAR ENERGYSTAR a° Andersen®. Andersen - NFRCCertifed Products ° ° i7 W 2010 2010 m y Product Line& Grille Type m- m« - - Glass Type DirectoryNumber x Product Type .� 7 E E ¢ m o c p Z 2 ui N 2.2'Annealed Glass,•w/No Grilles and Grilles Less Than 1" - - No Grilles AND-N5940849-00001 0.29 C65 0.32 0.55 '22 0.07 - - - - yl Simulated Divided Lit.(SDL)or Installed Interior Removable AND-N59-0g849-00002 0.29 1.65 0.29 OA9 20 O.07' - - - - A Full Divided❑te(FOL) AND-N59-0O855-00001 0.31 1.76 0.29 0.49 17 0.07 - Flnenght"'(grilles-between4he-glass) ANIM5940867-00001 0.30 1.70 0.29 OAS 19 -0.07 - - No Grilles - ANIM59-00850-00001 0.30 1.70 020 0.30 14 0.07 1(1 c Simulated Divided Llte(SDL)or Installed Intedor Removable AND-NS9-0OS50-00002 0.30 1.70 0.18 027 12 0.07 - - f° Full Divided We(FDL) AND-N5.9-00856-00001 0.31 1.76 1 0.18 027 11 0.07 - FinallBhtry(grilles-between4heSWss) AND-N59-00868-00001 0.31 1.76 0.18 027 11 OAT No Grilles - AND-1459-00851-00001 0.29 1.65 021 OAS 15 0.07 - U`; Simulated Divided Lite(SDL)or Installed Interior Removable ANM.59-00851-00002 029 1.65 0.19 OM 14 0.67 3N EFull Divided Lite(FDL) AND-N39-00857-00001 0.70 1.70 0.19 OA4 13 0.07 - - - FIna11gh0"(grilles-between-the-glass) AND-N59-00869-00001 0.30 1.70 0.19 OM 13 0.07 - -No Grinos AND-N59-00848-00001 0.30 1.70 0.53 0.60 33 0.07 - - - C - c u/N Simulated Divided Lite(SDL)or Installed Interior Removable AND-N-59-00848-00002 0.30 1.70 OA7 0.54 29 0.07 - - C' - m J N Full Divided Lit.(FDL) AND-N59-00854-00001 0.31 1.76 OAT 0.54 28 0.07 - m Finenght"(grinee-0etween-theglass) AND-N59-0086640001-1 0.31- 1.76 1 OAT I C 2g 0.07 - - - - - 2.2 Annealed Glass-w/Grilles 1"or Greater - - - Simulated Divided Llte(SDL)or.Installed Interior Removable AND-N594084940003 029 1.65 026 6A3 18 0.07INS -11 '11 11 - -' E Full Divided Llte(FDL). AN13NS9-0OSS1-00001 0.30 1.70 026 OA3 17' 0.07 HLII FlnellghtTM(grilles-between-theglass) - AND-N-SS-0087340001 0.31 1.76 0.29 OA9 17 0.07 Simulated Divided Lit.(SDL)or Installed Interior Removable AND-N59-00850-00003" 0.30 1.70 .0.16 624 11 0.07 - - u N Full Divided Lite(FDL) AND-N59-00862-00001 0.31 1.76 1 0.16 0.24 10 0.07 N- J Fineliahtn(grilles-betweendheglass) AND.N59-00874-00001 •0.32 1.62 0.18 027 10 0.07 - - - - d Simulated Divided Lite(SOL)or-Installed Interior Removable AND-N59-00851-00003 029 1.65 0.17 0.39 13 0.07 u Full Divided Lit.(FDL) - AND-1,15940863-00001 0.30 1.70 0.17 0.39 12 0.07 J E 200 Series Tllt- w Flneligh0(grilles-betwmn4heglass) AND-N59-0087540001" 0.31 1.76 0.19 OM 12 0.07 - - - - - Wash Double Hung A Simulated Divided Lite(SDL)or Installed Interior Removable AND-N59-0OB4S-00003 0.30 1.70 0.42 0.47 26 0.0T' - G Ly N JFull Divided Lit.(FDL) AN".6940860-00001 0.31 1.76 OA2 OA7 25 0.07 - y Finelight-(grilles-befweon-th°ylesa)' AND-N59-00g72-00001" 0.32 1.82 0.47. 0.54 27 0.07 3.1 Annealed,or 3.1 Tempered Glass-w/No Grilles and Grilles Less Than i" No Grilles AND-NS940879-00001 0.30 1.70. 0.32 6.54 21- 0.07 - - - - - yl Simulated Divided Lite(SDL)or Installed Interior Removable AND-NS940879-00002 0.30 1.70 0.29 0.48 19 0.67' - - - 3 J° Full Divided Lit.(FOL). ANDN59-0OS85-00om 0.31 1.76 0.29 OAS 17 0.67 - - - - Flnellgh0(grilfes-between-theglass) AND-N59-00897-00001 0.31 1.76. 029 0.48 17 :0.07 - - - No Grilles AND-1159-0088040001 6.31 1.76 020 0.30, 12 0.07 - - - - Ly c Simulated Divided Lite(SDL)or Installed Interior Removable AND-N5940880-00002 .0.31 1 1.76 0.18 027 11' 0.07 - - - 3 0 J W Full Divided Lite(FDL). AND-NSM688S-00001. 0.31. 1.76 0.18 1 027. 11 0.07 - - R-light"' AND-N59-0089840001 '0.32 1.62 OA8 027 10 0.07 No Grille. AND-NS9-00881-00001 0.30 1.70 021 OAS 14 0.07' 3. Simulated Divided Llte(SDL)or Installed Interior Removable AND-459-00881-00002 0.30 1.70 0.19 OA3 13 0.07 E Full Divided LIts(FDL) ANDN59.00887-00001 0.31 1.76 0.19 OA3 12 .0.07 - N- u) Flnetightls(9rilles4mWeon-theglass) AND-N59.00899-00001 0.31 1.76 0.19 OA3 12 0.07 - O No Grilles AND-N59-0087840001.1.0.31 1 1.76 1 0.52 0.60 31, 0.07 C N Simulatetl Divided Life(SDL)or installed Interior Removable ANDNSM0878-00002 0.31 1.76 0.47 0.53 28 0.07 - J°'m Full Divided IJte(FDL) ANDN59-00884-00001 0.32 1.82 OA7 .0.53 .27 '0.07 - - - - a - . . . . Finellght"'(grilles-between.,theglass) AND-N59-00898-00001: 0.32 1.82 OA7. 0.53 27 0.07. 3.1 Annealed,or 3.1 Tempered Glass-w/Grilles 1"or Greater - Simulated Divided Llto(SDL)or Installed Intedor Removable ANDN59-0087940003 0.30 1.70 026 'OA3 17 0.67 - - - J Full Divided Lito(FOL) AND-N59-00891-00001 0.31 1.76 026 OA3.: 16 Finelfght-(grilles-between-th"l-9) n/a n/a Na Na rda Na Na - - - - - - - Simulated Divided Lite(SDL)or installed Interior Removable AND-1,14940880-00003 0.31 1.76 0.16 024 10 0.67 Jy Full Divided Idle(FDL) AND-NS9-0089240001 0.31 1.76 0.16 024 10 0.07 - - - FlnenghPs(grilles-between4h.-glass) Na Na Na Na• Na We We . .. Dee boarent ea"r Febuery 11,2013 p"ge2ole9 - eM la reEiedbdmng..seepeq.lforma"Infamatbn. V I� APPROVED AS 1�10TED OA P.# FEE BY: NOTI UILDING DEPART TENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REOt?! r) FOR POURED CONCRF- I= Q. ROUGH-FRA'',',l'�G&.PLU.' ' 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. NEW WINDOW NEW WINDOW ALL CONSTRUCTION SHALL MEET THE 32"x32" 32"x32" REQUIREMENTS OF THE CODES OF N- YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDI , IONS OF EXISTING WINDOW NEW WINDOW EXISTING WINDOW J 0Ivf^'vT0 VV^ �J 32"x32" 32"x32" 32 x32" rllkrBv.ti,n D z SOLD OLG �t"�N Tn'�ST:ES = N,YS,DE EXISTING WINDOW EXISTING WINDOW EXISTING ENTRY DOOR EXISTING WINDOW SO I �LDHPC Y EXISTING WINDOW NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE SON r-----� m cy- AC I L----J Z REMOVE & N DISCARD w WOOD SHINGLE CLADDING UCCIFANCY PATCH MATCH OR TO Uct IS UNLAWFUL Li WITI~IOUT CERTIFICA NEW 38'x521,NDOW OPTISHUTTER 32'W 21,NDOW OF OCCUPANCY EXISTING MASONRY FOUNDATION 315 WESTPH ALI A AVENUE, M ATTI TU CK, NY 11952 E-N NORTH ELEVATION 315 WE S TP H A LI A AVENUE, M A TTI TU C K , NY 11952 WEST ELEVATION _1 . �,l _ E- S P SCALE. 4 — 11011 P-1 SCALE: 4" — 1 '0" 0 2' 3. - 4' 5' 10, Z 0 J_ D m o (P-�2KEYING PLAN - WEST END OF BUILDING NO TH 0 P-1 SCALE: 4" = 1'0" 0 cn Q w NOTES0 ' w 1] PROVIDE FRAMING FOR NEW WINDOW Z INSTALLATIONS AS SHOWN IN FRAMING DIAGRAM Q ON SHEET P-2. WINDOW ADDITIONS 2] WINDOWS WILL BE PROVIDED BY THE OWNER TO �Eo ARc 0 \��'ovGIAS pF THE BUILDER. 315 West Phalia Avenue �0 4 z 3] WINDOWS TO BE STRAPPED AND ANCHORED IN tip, t' PLACE SECURELY. New York 11952 s o� 4] WINDOWS TO BE STRAPPED AND ANCHORED IN ��, 0123oa 0 PLACE SECURELY. �� F OF NEB 0 Z 51 ALL DEMOLITION DEBRIS & CONSTRUCTION DEBRIS OVER THE COURSE OF THE WORK TO BE REMOVED w 0 Z Q AND DISCARDED ACCORDING TO TOWN RULES. 14 DECEMBER 2023 0 6] FOLLOW ALL DRAWINGS AND NOTES ESPECIALLY Z r. THE FRAMING OF NEW WINDOWS. 7 COMPLY WITH ALL BUILDING DEPARTMENT REVISIONS: REQUIRED INSPECTIONS AND APPROVAL BEFORE y CONTINUING TO NEXT PHASE OF CONSTRUCTION. NORTH ELEVATION 8] CORRECT ANY STRUCTURAL DEFICENCY DOUGLAS PEIX ARCHITECT DISCOVERED DURING THE WORK. P.O.Box 1444 ' KEYING PLAN MATTITUCK, NEW YORK 11952 P-1 NORTH Phone: 646-643-9888 P-1 SCALE: ll — 1'0" 0 2' 3' 4' 5' doug@dougpeix.com PP .1 1 path: [SHARE/aaKEYSER /KEYSER BARN ::: - BARN DRAWINGS 14 dEC 2023.dwg „ ,tr.... ;.. __- �_... �,. .r __ w:..3.�,:.'�«.,i.;m.a ..���4 m,::u.-• ,•iae t PAIR of 2x4 as TOP PLATE CRIPPLE or BLOCKING DOUBLE (joined) 2x HEADER WINDOWS up to 36" WIDE to have 2X10 WINDOWS wider than 36" to have 2x12 NEW WINDOW NEW WINDOW NEW WINDOW 32"x32" 32"x32" 32"x32" EXISTING WINDOW NEW WINDOW NEW WINDOW NEW PAIR of WINDOWS NEW PAIR of WINDOWS NEW PAIR of WINDOWS NEW PAIR of WINDOWS EACH 28 "�x72 EACH 28"x72 EACH 28x72 EACH 28"x72" TRIMMER STUDS TO SUPPPORT NO CHANGE 38"x52" 26"x40„ HEADER. , I XV FULL STUDS Ll EXISTINNG PERIMETER WALL IS FRAMED IN 2x4 STUDS EXISTING EXISTING EIE] BASEMENT WINDOW BASEMENT WINDOW i E-S SOUTH ELEVATION SINGLE 2x4 gas BASE PLATE � - 315 WESTPHALIA AVENUE, MATTITUCK, NY 11952 P-2 SCALE. 4„ - 11011 Z CRIPPLE STUD 0 J_ m 0 W Q rF-2FRAMING AT NEW WINDOW HEADERS w P-2 Not to scale 0 0 w z Q J WINDOW ADDITIONS o �t�ED ARCry 315 West Phalia Avenue ° p�' w M attitu ck �3. U) New York 11952 s a 0 01230 -3 0 U c� 14 DECEMBER 2023 0 CENTER FOUR WINDOWS BETWEEN PARTITONS CENTER FOUR WINDOWS BETWEEN PARTITONS z z REVISIONS: SOUTH ELEVATION DOUGLAS PEN ARCHITECT rp-1 KEYING PLAN P.O.Box 1444 P-2 SCALE: - 1 '0" NORTH o 2 3 4 5 10 MATTITUCK, NEW YORK 11952 4 — Phone: 646-643-9888 doug@dougpeix.com path: [SHARE/aaKEYSER /KEYSER BARN ::: -BARN DRAWINGS 14 dEC 2023.dwg]