Loading...
HomeMy WebLinkAbout50092-Z �o4�OF SOUl�,°!° Town of Southold * * P.O. Box 1179 0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45841 Date: 12/18/2024 i THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1120 Willow Dr Greenvort, NY 11944 Sec/Block/Lot: 40.-2-6.8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11/13/2023 Pursuant to which Building Permit No. 50092 and dated: 12/06/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Judith Evans Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50092 12/3/2024 PLUMBERS CERTIFICATION: A thoriz Signatur �o��OF SOUTya`o Town of Southold * * P.O. Box 1179 woe 53095 Main Rd coutm Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45842 Date: 12/18/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1120 Willow Dr Greenport, NY 11944 Sec/Block/Lot: 40.-2-6.8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11/13/2023 Pursuant to which Building Permit No. 50092 and dated: 12/06/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Battery storage system in accessory shed. No storage of combustible items permitted within shed. The certificate is issued to: Judith Evans Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50092 12/3/2024 PLUMBERS CERTIFICATION: "-Y� "-)� Auth if zed Si ture ho�,,,of Sag lyo� TOWN OF SOUTHOLD BUILDING DEPARTMENT Q TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50092 Date: 12/06/2023 Permission is hereby granted to: Judith A Evans 1120 Willow Dr Greenport, NY 1194.4 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Amended 12/2/24to include battery storage system in accessory garage. Premises Located at: 1120 Willow Dr, Greenport, NY 11944 SCTM#40.-2-6.8 Pursuant to application dated 11/13/2023 and approved by the Building Inspector. To expire on 06/06/2025. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total $325.00 Building Inspector SOUr��l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1]971-0959 "el Sao Jamesh southoldtownny.gov OUMY, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Judith Evans Address: 1120 Willow Drive city:Greenport st: New York zip: 11944 Building Permit#: 50092 Section: 40 Block: 2 Lot: 6.8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: Element Energy LLC Electrician: Jamie Minnick License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool - New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Reept Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 8kw roof mounted pv solar energy system with 20 Canadian solar CS-6R 400watt Modules,20 micro inverters IQ8PLUS-72-2-US,1 ac fused disco 40amp, 1 enphase combiner panel Notes: 1 battery backup sonnen core+ SOLAR ENERGY SYSTEM Inspector Signature: Date: December 3, 2024 1120 willow dr OF SOUIy�� TOWN OF SOUTHOLD BUILDING DEPT. V 6 • ,O 631-765-1802 INSPECTION [ ] FOUNDATION.1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ . ] FRAMING/STRAPPING [ PY FINAL _301e,4-- [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY-INSPECTION [ -] .FIRE RESISTANT CONSTRUCTION [ ] 'FIRE RESISTANT PENETRATION, [ ] ELECTRICAL (ROUGH) [ ] -ELECTRICAL (FINAL) [. ] CODE VIOLATION [ ] PRE. C/O [ ] RENTAL REMARKS_: l w`f�l s DATE o?- -a INSPECTOR SOUIyOIo t��9c'f �tao cv rCo�v * ` TOWN- OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION.1ST/ REBAR [ ] ROUGH PLBG. ] FOUNDATION 2ND [- ] INSULATION/CAULKING ] FRAMING/STRAPPING [ ] FINAL [ ] .FIREPLACE & CHIMNEY [: ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION= [ ]. FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [f C] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] 'PRE C/O [ ]. RENTAL REMARKS: SD f- /a . I ,v� L0aj GI'O55 !� a 6 l ;O sC-0yi1 -�L DATE INSPECTOR Zoho Sign Document ID:2A768FFA-ZVVUI2YSFJFPSW2LP15YJKZQZGLQ4G-NO6HTLMIUVZG P'Q� 1 Town of Southold D E C E anusry 4th, 2024 Building Department Town Hall Annex Building JAN 2 1 2025 54375 Route 25 P.O. Box 1179 Building Department Southold, NY 11971 Town of Southold Subject: Battery Energy Storage System and Roof Mounted Solar Panels at the Evans Residence, 1120 Willow Dr, Greenport, NY 11944 To Town of Southold: Following the completion of the Solar PV System and Battery Energy Storage System (BESS) installation at the above-referenced property, I hereby certify the following: Solar PV System: The installation complies with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and other relevant industry standards. The structural integrity of the existing roof framing has been verified, confirming that it supports the additional loads imposed by the solar panels. The installation is in accordance with the approved construction drawings and manufacturer's guidelines. ,Battery Energy Storage System (BESS): The BESS installation aligns with the 2020 Residential Code of New York State, the 2020 Fire Code of New York State, UL9540A standards, and the NYS Building Code. The BESS enclosure design meets the required fire-resistant standards, and the system is appropriately safeguarded against thermal,runaway. In my professional opinion, the Solar PV System and the BESS have been installed correctly and meet all applicable codes and standards. The work performed has been executed in a manner that ensures structural adequacy, safety, and compliance. Please contact me if you require any further information or clarification. Sincerely, of NEIV Gennaro Anthony Giustra. P.E. ��P��o A Great Eastern Services, Inc. �� l PO Box 240 u, 24 Harvey Rd 2� - Riverhead, NY 11901 103443 Mobile: 631.235.0189 AR��ESS1oNP� Email: jerrygiustra@gmail.com MELD INSPECTION REPORT DATE COMMENTS vlb Q FOUNDATION (1ST) ------------------------------------ -- FOUNDATION (2ND) 590 0 � ROUGH FRAMING& PLUMBING — 1 r INSULATION PER N.Y. STATE ENERGY CODE ;/V s 2.cs. OA,. o s�,� o cow hvs Iles Ale . o. FINAL Q�Itd�Y�( p�eGrj2/G•¢� C.'e/e-7�T7C ADDITIONAL COMMENTS 99, 0 S\f rn In AaafarvA Ce e- z N � _ � o z x x d b H 1 l:o�fFOl,YL,>_ s %'. ''1'OWII'i OF SOUTHOLD - B>l1Iil,DHNG DEPARTMENT� Toxin ball Annex 54375 main Road P. 0. Box 1179 Southold. NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 hugs: ^l�"rmv.Y i Date Received j l APPLICATION FOR BUILDING PERMIT i For Office Use Only i D E C E I PERf•JlITNO. ��j I I Building Insp ; I Inspector: NOV 9 3 2023 I Applications and forms must be filled our in their entirety.Incomplete I iapplications will not be accepted. Where the Applicant is not,the.owner,are building Department Owner's Authorization form(IPage•2)shall be completed. Town of Southold � I j • Date: IName: } � SCTM#1000- 0 40,00 —oEL. ,v0—vo", "n Project Address: 11 2.0 r 11 �r pY �1 I9y j �. Phone#: l ® cp �l Email: p. Y`✓'n Mailing Address: C o)-C) l 0V.-,) r. Cyr orb I'1 n q L I - Name: L-'J 5r Mailing Addrt41 - "` - j �'� Phone#: . Email: DESIGN PROFESSVONAL TNFif51RMAT OLN: Name: Mailing Address: �i Phone#: Email: —CONTACTOR aNFOA71 .- Name: Y'�t:,1'�`�' ��� .��a�_• it�, � f Mailing 7 _ �('1 l�l , J1v Phone#: Email: f � i _ DgSCPJP C)N OF PROPOSED CONSTRU,CTt i ❑,"New Structure ❑Addition Alteration ❑Repair ❑Demolition Estimated Cost of Project: i tOther ', C, .I 6UK- ,,P 1, S ��� ;� � � I $ `�'`I (0 8 , Will the lot be re-graded? ❑Yes C'f�o Will excess fill be removed from premises? ❑Yes"PIN o -7�sx, v7� L C �� 1 r L/I _ ' G-GY�r1 10. !� I t /Vt{'i A✓1� 1 0 40 j PROPERTY INFORMATION radditions, use of property: Intended use of property: I r use distric which premises is situated: Are there any covenants and restrictions with respect to Z this property? ❑Yes No IF YES, PROVIDE A COPY. ck Box After Reading: The owner/contractor/design professional is responsilife for all drainage and storm water issues as provided by 36 of the Town Code. APPUCATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone .of•the down of Southold,Suffolk,County,New York and otter applicable Caws,Ordinances or Regulations,for the construction of buildings, alterations or for removal or demolition as herein described.The applicant agrees to comply with ail applicable laws,ordinances,building code, de and regulations and to admit authorized inspectors on premises and in buifdfng(s)for necessary inspections.False statements made herein are as a class A misdemeanor pursuant to Section 218.4.5 of the New York State Penal Law. i f Application Submitted By(print name): Lo rJ'-�l..i-n-ey � 8 ����'� YAuthorized Agent ❑Owner Signature of Applicant: �u ILL-A-e #'�� Date. I !� STATE OF NEW YORK) SS: COUNTY OF J Q. Po k— ) bo I being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Cl— �G� r (Contractor, Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. i Sworn before me this day of OU/v�el 2023 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, t~d I ✓0,113 residing at 1 Z O i l SOW 1 � lL l3'C.�B OV L©ref � J do hereby authorizere U C-VLapply on my behalf to the Taw of Southold Building Department for approval as described herein. r Owner's Signature Date LOUIS J ROMEO Notary public,State of New York No.01 R06314813 �. Print Owner's Name Qualified in Suffolk County commission Expires November 17,-20a(� i 2 AI`CCOR� CERTIFICATE OF LIABILITY INSURANCE DATE(M 7112I2o Mroaryvyy�3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURERS), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rfghts to the certificate holder in lieu of such endorsement(s). PRODUCER ROBERT S.FEDE INSURANCE AGENCY NAME: 23 GREEN STREET,SUITE 102 PHONE No Ext: A1C No HUNTINGTON,NY 11743 ADDRESS: r747 DE INSURANCE INSURERS)AFFORDING COVERAGE NAIL s INSURER A:ATLANTIC CASUALTY INS.CO. 524210 gy LLC '"$�a' RA T ENERGY SYSTEMS aHSArRenc AVENUE INSURER 0: Y 11952 °NsuRERE: COVERAGES LNsuRt_rt F CERTIFICATE NUMBER- REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTMTHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLANS, INSR PO 0 LTR TYPE OF INSURANCE IA POLICY SW POLICY NUM�R EFF COMMERCIAL GENERAL LIABILITY LIMITS A CLAIMS-MADE fx�occuR X X 1-1460036873 7114/2023 7114I2024 E4CHOCCURRENCE s 3,000,C00 I PREAAISES 4F,aaa,rance $ 100'000 X ContractualLia IMA3E9203B MEDEXP(An OFT@ n) $ 5000 GENL AGGREGATE LIMI7APPLiES PER: 7119/2022 7/19/2024 PERSONAL a AOV INJURV 3 3000000 I GENERAL AGGREGATE i 3. 0,000 POLICY a JPE. Q LOC I PRCIDI1eTs-eoroP AGG s OTHER: : AWOM TOMOBiLE LNBILITY COMBINED SINGLE LUAIT ANYAUTO Ea $ AZ SCHESDULEO e001LY INJURY(Per person) $ AUTOS ONLY AUTGS BODILY INJURY(Per asrdnq S HD3ED NON-pNMEp AUTOSONLY AIFTOSONLY R PEDAMAGEper amident $ UMBRELLA LJAB OCCUR $ EXCESS LIAB CLA)MS-MADE EACH OCCURRENCE $ AGGREGATE $ DED REIENf1CN$ I 1NORKEIts COMPENSAMN $ AND EMPLOYERS'LIABILITY 124494445 PER OTH ANY PROPRIETOWPARTNEWEXECUTIVE YIN 7/1M023 7/13/2024 A ER 8 OFFICERtMEMBER EXCLUDED? NIA E L EACH ACCIDENT $ 1 OW 000 IYa ,atmydescr under.7n NFL) It Fes, EL DISEASE-EA EMPLOYE $ DESCRIPTION OF OPERATION$pelow 1000 EL DISEASE-POLICY LIMR $ NY State DBL DBL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONSI LOCATIONS I VEHICLES OCORD 101,AddlOenal Remarks Sdiedule,may be attached B store space is raw" CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATEHOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Fedpe, Arnlars is nn7�Inax ©1988-2015 ACORD CORPORATION. All rights reserved. 7*4—At'non..ns,....a..el 1....,.non.n..:oF,.+...a­E. _r nr+nq3n BUILDIING DEPARTMENT- Elcec trlcafl i nspe01 TOWN OF SOUTHOLD �s��� y1 4 Town Hall Annex - 54375 Main road - PO Box 1179 z Southold, New Fork 11971-3959 -telephone (531) 765-1302 - FAX (531) 765-9502 rogeflrA�sguthaP townny gov- seand(a-southoldtownny aov APPLICATION FOR ELECTRICAL INSPECTION FLi.cense IAN INFORMATION (All Information Required) Date: �� (3 jCompany Name: 1 �Y ;,°� ,P Elearne: I . ) , i o.: EIec. ernai1: r'°✓Y P .a . �� �'% (`, J r C .`� '� e J�o: !( T a 9 ., 0I request an email copy of certificateof�orn�9iance es - _� I r JOB SITE WORMATION (All information Required) j Dame: a,4- I ,Address: L l 7'-d �11 ou-� r` ►, ,ao Cross Street. _ �� `7 � Phone �90.: ,- �j o- j Bldg.Permit I: �f � emai � d = =� Tax flap District: 1000 Section:0 y o.�o Block: 0 2. Do Lot: 00(o. oog BRIEF DESCRIPTION' OF WORK, I cLUDE SQUARE FOOTAGE (Tease Print clearly): 9 GG> � w'�� 11 Square Footage: Corals /App That App[lyo Is job ready for inspection?: E] YES N 0 FI Rough �n Final Co you need a Temp Certificate?: YES NO Issued On lor p Information.- (All information required) j Service SizeEl1 Ph03 Ph Size: A Meters Old Meter# Nlew Service®Fire Reconnect[] Reconnect®Service Reconnect®Underground overhead derground Laterals r 1 , ;2 la l= Pole Work done on Service? Y N Additional Information,: ` �I tom, t',��„ � PA`DA,ENT DUE WITH A'PPLIC,ATI JN XR-1 LOB ,g,;F s TDL�B3t NYSIF Now York State Insurance Fund PO Box 66699,Albany,NY 12206 I nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 0 Q "A°AAA 823336604 = ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS T4379 MAIN ROAD 7470 SOUND AVENUE 54375 MAIN O 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 - 369075 - 0711312ID23 TO 07/1312024 7111112023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORKSTATEINSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTIPS:iP V1 M.NYSIF.CONUCERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY_ NEW YORK STAT SU NCE FUND OIRECTOR,INSURANCE FUND UNCERWRITING Yoawtc Workers' CERTIFICATE OF INSURANCE COVERAGE sraTc Board nation NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Fancily Leave benefits carrier or licensed insurance agent of that came ll 1a.Legal Name 8 Address of irisw s o ed(use street addresnly) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTiTUCK,NY 11952 1 c.Federal Employer Identification Number of insured Work Logtior,of Insured on1 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate bolder) TOWN OF SOUTHOLD shetterPoint Ufe Insurance Company 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"W SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01101/2023 to 12/31/2024 4. Policy provides the following benefits: ® A_Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® Ai.All of the employer's employees eligible under the NYS Disability and Paid Family Leave 8enerds Law. C] B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that 1 am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/1012023 By ��9,&t (signature of insurance Carr ers authorized representative or NYS licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and rue Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holler. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To he completed by the NYS Workers'Compensation Board(only If cox 46,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By Wgnature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title I Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance peCcies and NYS licensed insurance agents of those insurance carriers are authorized to issue Fcrm DB-12t7.1.Insurance brokers are NOT authorized do issue this form. DB-120.1 (12-21) 11111 di�l�l9��ll���ll�ll�iil11lf�lll�( A ® CERTIFICATE OF LIABILITY INSURANCE oaTEla 7/12f2D 3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. rSOUND ORTANT: If the certificate holder is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. BROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on certificate does not confer rights to the certificate holder in lieu of such endorsement(s). ER RT S.FEDE INSURANCE AGENCYJA _ FAX EEN STREET SUITE 102 Exl. - Nu INGTON,NY 11743ADDRESS: g RT S.FEDE INSURANCE INSUR S)AFFORDI NAIC p RA:ATLANTIC CASUALTY824210 nt Energy LLC R LEMENT ENERGY SYSTEMS : OUND AVENUE °=TUCIC,fVY 11952 E: RISURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. =CFrHER: NOF INSURANCE OCLPOLICYNUfilBER POLIC EFF w�Y EvU9 L GENERAL LABILITY L148D038873XX 7/1412023I 7/1412024 EACH OCCURRENCE $ 3,000,000 MADE OCCUR PREMISES Ea coc�urence s 100.000 tractual Lia 1�=03B MED EXP IAn we Per5m) $ 5000 7119/2022 7/192024 PERSONAL 6 AOV INJURY $ 300000() LIMI7APPLIES PER: GENERAL AGGREGATE i 3,000,000 ECT []LOCPRODUCTS-COMWOPAGG S i AUTOM08rLE l.iABHJTY COOMBI (SINGLE LIMIT ANY AUTO s OVY 4ED SCHEDULED BODILY INJURY(Per person) s HIRED OS ONLY AUTOS BODILY lN.URY(Per amid".) S NON-OWNEDPE AUTOS ONLY gIITpSONLY OpILy PRO RTY DAMAGEPet acddenl $ 3 UMBRELLA LIAR OCCUR ExCESS LLAS "SUS-MADE EACH OCCURRENCE $ AGGREGATE g DED RETENTION$ WORKERS COMPENSATION I2449+{445 PER OTH S AND EMPLOY£RTUABLITY ANY PROPRIETORIPARTNERIFXECUTIVE YIN 7/132023 7/13lZOZd A ER $ OFFICERIMEMBER EXCLUDED? � NIA E L EACH ACCIDENT S 1 000 000 tMlulda"In Mfg If yes,describe wider EL DISEASE-EA EMPLOYE 3 DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT S NY State DBL aBLss7sz7 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS 1 LOCATIONS f VEHICLES fACORD 101,Addblonaf Remarks Schedule,may be atlaebad If more Space is Mcpd" CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtficate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE MILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE P -tS. Fedz ©1988-2015 ACORD CORPORATION. All rights reserved. ern®r1 ?s r7MRfrttl T9.a Af^n�n ..I I. . .... .:ab a. a_—5 A("f%Crn Zoho Sign Document ID:2A768FFA-_EYCNIKPA2MBOCVTIBFOUEXP6TP9RO5PV_NHQRTFJKM Town of Southold November 9th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold,New York 11971-0959 Subject: Roof Mounted Solar Panels at the Evans Residence, 1120 Willow Dr. Greenl2ort, NY 11944 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds,per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 3.0 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. OF NEW�Q.�� o A c� O Great Eastern Services, Inc. PO Box 240 24 Harvey Rd m Riverhead, NY 11901 Mobile: 631.235.0189 BAR 10340 P� OFESSION Email: jerrygiustra@gmail.com Zoho Sign Document ID:2A768FFA-_EYCNIKPA2MBOCVTIBFOUEXP6TP9RO5PV_NHQRTFJKM za DESIGN S DRAFTING BY: S P E O F WORK ELEMENT ENERGY LLC TO INSTALL A 8 KW 50LAP PHOTOVOLTAIC(PV)5Y5TEM AT EVAN5 RESIDENCE, REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 1 120 WILLOW DR, GREENPORT, NY 1 1944. 05. ' ,2-,2� THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EX15TING ELECTRICAL SERVICE EQUIPMENT. REVISIONS .e; .,,--„ •. ?E5CRIFn0N DATE REV SYSTEM RATINGMe GINAL -09-2023 8 kW DC 5TC EQUIPMENT SUMMARY 20 CANADIAN SOLAR C5GR-400 WATT PV MODULES 20 ENPHA5E I08PLU5-72-2-U5 MICRO INVERTERS t CONTRACTOR I IRONRIDGE XRI00 MOUNTING SYSTEM � ELEMENT ENERGY, LLC. SHEET INDEX - -1 7470 SOUND AVE PV-I COVER J MATTITUCK, NY 1 195 PV-2 SITE PLAN PROJECT LOCATION LICENSE# G74G 1411 PV-3 ROOF PV LAYOUT LICENSE# 52G89-ME PV-4 STRUCTURAL/DETAILS 4 5ECTION5 PV-5 3-LINE ELECTRICAL DIAGRAM PV-9 LABELS pF NEby �P G GOVERNING CODES 0A � � 2017 NATIONAL ELECTRICAL CODE. 2020 RE5IDENTIAL CODE OF NEW YORK STATE. n ' W 2020 FIRE CODE OF NEW YORK STATE. ti - 2 ASCE 7-1 C AND NFPA-70. N (� UNDERWRITERS LABORATORIES(UL)5TANDARD5 ,, 103443 05HA 29 CFR 1910.2G9 rp�SSt�1P� GENERAL NOTES ELECTRICAL INSPECTION REQUIRED FRCJECT NAME CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT lU THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE u- U _> HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK w Z _� AGREE THE SAME. AERIAL VIEW W C _ 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, - INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP q) 00 z AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, compwW -I COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES ALL CODES 0 co 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO MMYEP AS DOTED NEW YORK STATE&TOWN CO E O O ALL RULES AND REGULATIONS OF THE RESPONSIBLE o JURISDICTION. COMMENCING WITH WORK. f� 7 AS REQUIRED AND CONDITIONS o z C z 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ap.� - o- MAINTAINING SAFETY ON THE JOB SITE DURING THE :� D- Q CV ILL WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, - S�1IHOLDTOWN, p CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ��60 THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND �"�'�"'�' - S"OID TO LLu - ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT NOTIFY 8UWNG DEP T N1NG�O CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, 631 765.1102 8AM TO 4PM FOR THE SDUTH WN TRUSTEES RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY FOLLOWING INSPECTIONS: v 5. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE N,Y,S, C SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT COVE IN DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING 2. ROUGH-FRAMING&PLUMBING H FABRICATED AND INSTALLED AS PER LATEST A.LS.0 j 1. FOUNDATION-TWO REQUIRED OLDH� SPECIFICATIONS. CONSTRUCTION. FOR POURED CONCRETE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE U. ALL ELECTRICAL WORK SHALL BOARD OF FIRE 0 UNDERWRITERS APPROVED AND N ACCORDANCE WITH N.E.C. 4 CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES�REGULATIONS 3. INSULATION 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS ANDCOMMENCING WITH WORK. 4. FINAL-CONSTRUCTION MUST (' �° CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING C U FANS,r 0R DRAWING SCALE CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THI5 BE COMPLETE FOR C.O. 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE 51TE AND DISPOSE OF IN A LEGAL MANNER ON ALL CONSTRUCTION SHALL MEET THE USE IS UN� AWFUL N 'T.S A WEEKLY BA515 OR SOONER IF CONDITIONS WARRANT. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED REQUIREMENTS OF THE CODES OF NEW � PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. �rl 'BOUT CERTIFICA-F THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE YORK STATE, NOT RESPONSIBLE FOR ITi LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE DESIGN OR CO STRUCTON ERRORS EXTENSIONS TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF '� OCCUPANCY sHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. , PV- EXISTING WORK ADJACENT TO HI5 WORK, OR DAMAGED AS RESULT OF HIS WORK. - - -- -- TAX MAP: 1 000-040.00-02.00-OOG.008 Zoho Sign Document ID:2A768FFA--EYCNIKPA2MBOCVTIBFOUEXP6TP9RO5PV_NHQRTFJKM LEGEND TAX MAP: 1000-040.00-02.00-006.008 DESIGN 6 DRAFTING BY: � I UTILITY METER REVIEW BJ.M.NABC P CERTIFIE ENT ENERGY LLC MAINN SERVICE RVICE PANEL NEW PV SUB-PANELS 051112-129 A/C DISCONNECT COMBINER INVERTERS _- GND ELECTRODE REVISIONS PV NODULE 1 2'- 1�" DESCRIPTION DATE REV ORIGINAL 11-09-2023 RACKING RAIL O ATTACHMENT POINT ---RAFTERS PROOF PITCH ANGLE BSUNRUN METER NVENT OPLUMBING VENT ®SKY LIGHT ol - �= CONTRACTOR MCHIMNEY COMPOSITE MINGLES ELEMENT ENERGY, LLC. ®CO N PPOTECON NTIALDMON HARING ISSUES 22'- 1 04" I55ROOF 7470 SOUND AVE �-—TRIM/REMOVE AS NECESSARY MATTITLICK, NY 1 1952 LICENSE # G74G I-HI LICENSE # 52G89-ME /D /y 3 OF NEigry P oA O CL tp FQ T03443 PROJECT NAME LLJ 0 W > w z O L ILJ o — '�- C) > cf) OLLJ J nz�� ACCE55 ROOF ACCESS ROOF (n J Lr O ;m LLJ jN z O z 0 ._ EL Q CV Lu > — Cz uw — 5HEET NAME SITE PLAN N po I .FAVVING 5CALE 131- 113" V/270 a /811 = I I—OIL 4 �90°E CONSTRUCTION NOTES 240° 210° D 120° 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE °1800150 5HEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. p� /_ 2.)ALL OUTDOOR EQUIPMENT 5HALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. S I V 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Zoho Sign Document ID:2A768FFA-_EYCNIKPA2MBOCVTIBFOUEXP6TP9RO5PV_NHQRTFJKM CONSTRUCTION SUMMARY LEGEND DEIGN G DRAFTING BY: (20)CANADIAN SOLAR C56R-400 WATT PV MODULES �oasTIN unuTr METER ELEMENT ENERGY LLc (DIMENSIONS: G7.8"X 44.0 X I.4") MAIN SERVICE PANEL REVIEW BY J.M.NABCEP CERTIFIE (20) ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS NEW PV SUB-PANELS 051112-129 A/C D6CONNECT (G2)ATTACHMENT POINTS @ G4"O.C. MAX. COMBINER (248.3) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. INGIN RTERSooE REVISIONS ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) DESCRIPTION �A E REv ®PV MODULE ORIGINAL I -09-2023 CONSTRUCTION NOTES 21-I o-1 �RACICING RAIL 1.)ALL EQUIPMENT SHALL DE INSTALLED IN ACCORDANCE o ATTACHMENT POINT WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ---RAFTERS 2.)ALL OUTDOOR EQUIPMENT SHALL 5E RAINTIGHT WITH -ROOF PITCH ANGLE MINIMUM NEMA 3R RATING. �suNRUN METER 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE - FIELD VERIFICATION. 2 1 ®VENT 4 0PLUMBING VENT ®SKY LIGHT ®CHIMNEY CONTRACTOR lu ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD CONDITION iD ACCE55 ROOF POTENTIAL SHADING ISSUES 7470 50UND AVE �> TRIM/REMOVE AS NECESSAR MATTITUCK, NY 1 1952 LICENSE #G74G I-HI A Y#2 LICENSE# 52G89-ME G MODULES 29' PITCH j 2G I°AZIMUTH pF NEt�,Y � �P�pSiO�A,GiGsp�Q� w �O T03443 ���sstoNP� PROJECT NAME O j w z m O � o - z ;m g Lu __j i ACCE55 ROOF ACCE55 ROOF Ln O O o ARRAY#1 %N 0 z O z 14 MODULES 0- Q N Lu 29'PITCH % 0 > — 2G I'AZIMUTH LLJ — SrIFFT'FAME 711 N PV LAYOUT oo ® ® I DRAWING SCALE EW PV AC D15CONNECT w270 Q `2 15TING MAIN ELECTRICAL SERVICE PANEL 2400 �9o.E I/811 15TING UTILITY METER 2lo pD 1200 1U0ol50o S SHEET NUMBER PV-3 TAX MAP: 1 000-040.00-02.00-000.005 Zoho Sign Document ID.2A768FFA-_EYCNIKPA2MBOCVTIBFOUEXP6TP9RO5PV_NHQRTFJKM ITEM DESCRIPTION ARRAYS#1-2 LOAD CALCULATION ARRAY# Ai<KAY#2 RB Rid e Bearn/Board 2"X 8"D. FIR DESIGN 6 DRAFTING BY: ELEMENT ENERGY LLC R Rafter 2"X G"D. FIR I G"O.C. REVIEW BY J.M.NABCEP CERTIFIE MODULE WEIGHT(Ibs) 45.1 45.4 P Pitch 29° 051 1 1 2-1 29 (D) Deckrn 5/8" PLYWOOD #OF MODULES 14 G J Ce1hn Joist 12"X G" D. FIR I G"O.C. TOTAL MODULE WEIGHT(Ibs) G77.G 290.4 �� REVISIONS DE5CR1PnON DATE REV TOTAL LENGTH OF RAIL(Ft) 173.5 74 512an f ORIGINAL 1 1-09-2023 RAIL WEIGHT PER FOOT(Lbs) 0.G8 O.GB P,B) TOTAL RAIL WEIGHT(Lbs) 115.2 50.7 (� - #OF 5TRANDOFF5 z2 20 WEIGHT PER STRANDOFF(Lbs) 2 2 TOTAL STANDOFF WEIGHT(Lbs) 84 40 TOTAL ARRAY WEIGHT(Lbs) 579.8 381.1 POINT LOAD(Lbs) 20.3 19.1 CONTRACTOR TOTAL ARRAY AREA(59 Ft) 299.7 25.s ELEMENT ENERGY, LLC. 7470 SOUND AVE ARRAY DEAD LOAD(Lbs/Sq Ft) za MATTITLICK, NY 1 195 C) LICENSE # G74G I-111 GROUND WIND DESIGN SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE BARRIER AIR MEAN LICENSE # 52G89-ME FLOOD SNOW DESIGN Frost DESIGN UNDERLAYMENT HAZARD59 FREEZING ANNUAL ( ) LOAD' Speed" Topographic Special Wmdborne CATEGORY TEMP` REQUIRED' INDEXI TEMP k ' Weathenng' line Termite` ��O W y (mph) e{fects vend region debns zone"' depthb f NE FEMA 23 40 NO NO NO B SEVERE 3 FT HEAVY 5°F YES ZONE X 599 51°F �P��o�A �yG�O,pr MANUAL J DESIGN CRITERIA" ([1 n w Indoor m 2 Elevation Latitude Winter Summer Altitude correction factor design Design temperature cooling Heating temperature (J) N heating cooling tempera difference (J) 103443 ture 1 OS tT 4 i°N 15°F 8G°F 1.00 70°F 75°F 55°F Wind Wmd Winter PROJECT NAME �ooling temperature difference velocity ng ty velocity Daily range humidity humidity - ROOF FRAMING DETAIL I wet bulb humidity [LJ heating cooling O W � F 15 MPH 7.5 MPH 72'1` MEDIUM(M) ZO Ic 32 GR @50%PH in For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. w LLJ Z Q a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth N _C) strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as ^ O Z determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. MODULE MOUNTING CLAMP L 1 b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction 0 ) shall fill in the frost line depth column with the minimum depth of footing below finish grade. 0) L� O C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. SOLAR MODULE Q d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined STAINLESS STEEL 3/8" N v J on a site-specific basis in accordance with Section R301.2.1.4. BOLT AND NUT O Z 0 Z e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York D_ Q IN LLJ State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official [Also o _ � see Figure R301.2(1).] a _ f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. NRIDGE ALUMINUM RAIL W g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the ALUMINUM"L"BRACKET Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: SHEET NAME i.The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM FLASHINGii.Flood Boundary and Floodway Map(FBFM),and p^ iii.Related supporting data along with any revisions thereto. 5T RU CTU RAL The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. In. In accordance with Sections R905.1.2,R905.4.3.1.R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." ASPHALT SHINGLE ROOF i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) 5/1 G"x G"STAINLESS value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." STEEL LAG BOLT WITH j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 2 112"MIN THREAD DRAWING SCALE (Base e PENETRATION SEALED AS NOTED k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the WITH GEOCEL 4500 jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) 1. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. M. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. SHEET NUMBER n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. F /_4 o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at MOUNTING DETAIL I I �/ elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. TAX MAF: 1000-040.00-02.00-OOG.008 (') See Figure R301.2(4)B. Zoho Sign Document ID:2A768FFA-_EYCNIKPA2MBOCVTIBFOUEXP6TP9RO5PV_NHQRTFJKM DESIGN B DRAFTING BY: 50LAR ARRAY ON MAIN HOUSE 8 kW (20)CANADIAN SOLAR C5-GR 400 WATT PV MODULES ELEMENT ENERGY LLC (1)STRING OF(1 1)MICRO-INVERTERS t(1)STRING OF(9)MICRO-INVERTERS REVIEW BY J.M.NA13CEP CERTIFIE (2)STRINGS TOTAL 051 1 1 2-1 29 TO UTILITY GRID REVISIONS STRING #I _ _ _ _ _ _ _ DE5CRIPTION DATE REV 1 N ORIGINAL 11-09-2023 r- ---------------- UTILITY METER ---------------------- POINT OF INTERCONNECTION PER NEC 240.21(B)(1)<G90.G4(A) I I STRING #2 5511A.LLNOTE�oFT I _ I I CONTRACTOR - ------- - _ _ ---- ------ 2 ONSE110 D1scoNNEa ELEMENT ENERGY, LLC. ENPHA5E BRANCH MICRO-INVERTER 7470 SOUND AVE CIRCUIT CABLE TYPICAL 240 VAC, 1.21 A MATTITUCK, NY 1 195 I ENPHA5E IQ&PLU5-72-2-U5 97%cec-wE1GHTEDEPF. LICENSE # G74G I-MI NEMA G,UL LISTED 1 1 I ENPHA5E AC COM13INER 4 ACD15CONNECT TYPICAL LICEN5E# 52G(59-ME I 240 VAC.50 A I NEMA arc ul UBTED 50 D D223NRB I -- (2)20 A DOUBLE POLE BREAFER5 240 VAC,60 A 1)15 A DOUBLE POLE BREAKER NEMA 3R.UL U5TED G - = EoR COMMUNICATION DEVICE 1 t (2)40 A FUSES '��OF NE Y O A 04 i ".. 40 A A O G'�G � I MAIN SERVICE PANEL LU ( --- i --- r' --------------------------------------------------� 240 VAC I I N 150 A O 103443 G - -� �O�SS1 I I I I I I I I I EXISTING GROUNDING I I I I ELECTRODE 5YSTEM PROJECT NAME -----------� I 0 LL.J LLJ > w z F m L------------------------------------- ------------ I 1 1-- LLI C) WIRE f CONDUIT 5CHEDULE C CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop 1% O z I.D. # ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION 51ZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE g W -1 310.15(B)(3) 31 O.15(5)(20(3c) O n/ INVERTERS COMBINER PANEL AWG#1 2 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 55QC 0.84 80 FT 2.0% N L� O OR EMT � w 2 COMBINER PANEL AC DISCONNECT AWG#8 1 3 THWN-2 AWG#8 I THWN-2 CU PVC I" 45QC 0.95 25 FT 0.5% 0 C Z Z 3 AC DISCONNECT LINE SIDE TAP AWG#G 1 3 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45QC 0.95 25 FT 0.5%Q w Q N ILJ _ � w W - ELECTRICAL NOTES 5hlt T NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Arnpacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90QC WET ENVIRONMENT. [NEC G90.8(B)(I)]:(I5c)'(#of stria 5)'(1.5G)= I G.G4 A 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 Modules per Stang I I MAX. TO,AND LOCATED AS CL05E AS P0551BLE TO THE NEAREST RIDGE,HIP,OR VALLEY. AWG#12,amp.G4 A Temp Derate= 20.size A 20.16 A> 16.G4 A,therefore AC were size Is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 20 COMPLY WITH NEC 110.26. #2 Inverter Output Wire Ampaclty Calculation 5.)DRAWING5 INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output'(1.25)=34.79 A Record low temp OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550RlE5 TO FULFILL AWG#8,ampacity'(Temp Derate)*(Conduit FLIT Derate)= 52.25 A Voc Tern Coefficient -0.24%a)QC DRAWING SCALE APPUCA13LE CODES AND STANDARDS. 52.25 A>34.79 A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXE5,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation THE CONTRACTOR 5HALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25)=34.79 A O eratin Current 10.8 A V I .T �j 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampacity'(Temp Derate)'(Coneluit Fill Derate)= 71.25 A Operating Volta le 37.4 V I I 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A>34.79 A,therefore AC wire size is valid. Max.System Voltacje 49.G V SUPPORT RAIL,PER THE GROUNDING CUP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEER LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR IL5CO GI3L-4D6T LAY-IN LUG. 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current 34.79 A Pv-5 OR O eratin AC Voltage 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1 000-040.00-02.00-OOG.008 Zoho Sign Document ID:2A768FFA-_EYCNIKPA2MBOCVTIBFOUEXP6TP9RO5PV_NHQRTFJKM SERVICE METER OI OO DESIGN 6 DRAFTING BY": _ IN5TALLATION NOTE ELEMENT ENERGY LLC REVIEW BY J.M.NABCEP CERT" SOLAR PV SYSTEM PHOTOVOLTAICPHOTOVOLTAIC ( I ) ALL LABEL SHALL BE INSTALLED IN 051112-129 EQUIPPED WITH SOV4RBREAKER DC DISCONNECT ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® OPERATING • REQUIREMENTS. RevlsloNs •. DESCRIPTION DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 11-09-2023 SOLAR AC LOAD CENTER - OUTSIDE w DO NOT RELOCATE Tr#S; •• . MAX SYSTEM VOLTAGE VDC REQUIRE FIELD VERIFICATION. o QEu` (3) LABELS, WARNING(5) AND MARKING O3 TURN RAPOSltnOWNSwICF1T0 O SHALL BE IN ACCORDANCE WITH NEC THE•OFF POSITION TO SHUT DOWN I 1 1 0.2 I (B). i PV SYSTEM AID REDUCE s SHOCK HAZARD INT*AWAY AC DISCONNECT CAUTION (4) THE MATERIAL U5ED FOR MARKING POWER TO THIS S'R N IS 450 SIRPIJED - - - - FRO•THE i01LOVMMG 5°IRiGES WfTH r7 MU5T BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE dSGWIHEGS Z °T-1° ` COMPLIANCE WITH NEC 1 10.2 1 (B)(3). (5) THE PV 5Y5TEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. NIN P..•,. 7470 SOUND AVE ® O7 ® 1 17M I SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 195 OF All P SUPPLY ?� COMPLIANCE WITH NEC 690.3 1 . LICENSE # G7461-11I lt7fFWEBYKXME VEMO000NM SOURCES:UTILITY GRID LICENSE # 52689-ME 01MEX ARM AND PV SOLAR DEMCE.8IMLLNDTORM ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING "!�OFaMAR OF NEWY 3Q 1 Af, ;VG C11 A THIS SERVICE METER r ELECTRIC SHOCK HAZARD i IS ALSO SERVED BY A TAIC SYSTEM , l PHOTOVOLTAIC SYSTEM TERMlU1LS ON THE U E AND COM13WR PAWL LOAD SDES MAY BE B6tG® DO NOT ADD LOADS �O 1034 A3 CONDUIT - OUTSIDE BUILDING V NTIEOPMPOSTION — � E stoNP• 16— O • • • PROJECT NAME f 0 LU lU LLM _> DUAL POWER SUPPLY � z E/ O> ISOURCES:UTILITY GRID AND! � � 2 PV SOLAR ELECTRIC SYSTEM LLJ MAIN SERVICE PANEL - OUTSIDE O Z A CAUTION SOLAR CIRCUIT O O LU J F- 0 ! �s" W > o • • • • o z o W 6 • ° > N - — MAIN SERVICE PANEL - INSIDE OPERATING CURRENTLLJ POWER SOURCE OPERATING •LTAGE • LTS i OUTPUT CONNECTION ® O DO NOT RELOCATE THIS OVERCURRENT DEVICE LABELS AC DISCONNECT/BREAKER DFANAG SCALE 0000G N .T.S. ,-"EET NUMb-�K PV-6 TAX MAP: 1000-040.00-02.00-OOG.008 Preliminary Technical �r� CanadianSolar 'lipInformation Sheet H i Ku6 (All-Black) ALL BLACK MONO PERC 380 W - 405 W CS6R-380 1 385 1 390 1 395 1 400 1 405MS-H L MORE POWER 25 Industry Leading Product Warranty on Materials Years and Workmanship* Module power up to 405 W 405 W Module efficiency up to 20.7% ; 2 Linear Power Performance Warranty* Years Lower LCOE&system cost 1•t year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% *Subject to the terms and conditions contained in the applicable Canadian Solar Limited Warranty Statement.Also this 25-year limited product warranty is available only for prod- Comprehensive LID/LeTID mitigation ucts installed and operating on residential rooftops in certain regions. technology,up to 50%lower degradation ...................................................................................._... .... .. ..... _.- MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015/Quality management system Better shading tolerance ISO 14001:2015/Standards for environmental management system ISO 45001:2018/International standards for occupational health&safety PRODUCT CERTIFICATES* MORE RELIABLE IEC 61215/IEC 61730/CE/INMETRO UL 61730/fEC 61701/IEC 62716 Take-e-way Minimizes micro-crack impacts v ■. (� DE CSP�SC E �e z *The specific certificates applicable to different module types and markets will vary, and therefore not all of the certifications listed herein will simultaneously apply to the ** Heavy snow load up to 7000 Pa, products you order or use.Please contact your local Canadian Solar sales representative wind load up to 5000 Pa* to confirm the specific certificates available for your Product and applicable in the regions in which the products will be used. ................................................................................................................................. CSI SOLAR(USA)CO.,LTD.Is committed to providing high quality solar photovoltaic modules,solar energy and battery storage solutions to customers.The company was recognized as the No.1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight *Pending testing confirmation.For detailed information, Survey.Over the past 20 years,it has successfully delivered over 67 GW please refer to the Installation Manual. of premium-quality solar modules across the world. .................................................................................................................................................................................................................................................................. CSI SOLAR(USA)CO.,LTD. 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597, USA I www.csisolar.com/na I service.ca@csisolar.com ENGINEERING DRAWING(mm) CS6R-400MS I-V CURVES A A Rear View Frame Cross Section A-A 14 4 13 13 A-A 12 ­112 ---------------- 11 ------------- --------------11 ---------------- ------------ Z 35 G­d,19 H111 10 ----------- ------------------- ------- M-infing Hole 7 -------------------- ------- -------- -------------- 6 ------ 6 ------------------- ------------ S ---------------- .... .............­ 5 .................... -------------- 4 4 ---------------- QQ 3 ----------- 3 2----------------- ------ -------- ------------------ Mounting Hole 0 1*4 5 10 15 20 25 30 35 40 45 SO 55 60 S 10 1S 20 2S 30 3S 40 4S 50 SS 60 ■ 1000 w/m, s-c ■ No w/m, ZS*c ■ 600 w/m, 45*c ■ • 400 w/m, Gsc ■ 200 W/m, ELECTRICAL DATA STC* MECHANICAL DATA CS611 380MS 385MS 390MS 395MS 40OMS 405MS Specification Data Nominal Max.Power(Pmax) 380 W 385 W 390 IN 395 W 400 W 405 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp)30.0V 30.2V 30AV 30.6V 30.8V 31.0V Cell Arrangement 108[2 X(9 X 6)] Opt.Operating Current(Imp)12.69 A 12,77 A 12.84 A 12.91 A 12.99 A 13.07 A 1722 x 1134 x 35 mm Dimensions Open Circuit Voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V (67.8 x 44.6 x 1.381n) Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 21.3 kg(47.0 lbs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti- Operating Temperature -40°C-+85°C reflective coating Frame Anodized aluminium alloy, Max.System Voltage 1500V(IEC/UQ or 1000V(IEC/UL) J-Box IP68,3 bypass diodes Module Fire Performance TYPE 1 (UL 61730 1500V)or TYPE 2(UL 61730 Cable 4 MM2(IEC),12 AWG(UL) 1 OOOV)or CLASS C(IEC 61730) Max,Series Fuse Rating 25 A Connector T6 or MC4 series Application Classification Class A Cable Length 1550 mm(61.0 in) Power Tolerance 0­10W (Including Connector) 850 mm(33.5 in) Per Pallet 30 pieces •Under Standard Test conditions(STC)of irradiance of 1000 W/ml,spectrum AM 1.5 and cell tempe- rature of 25*C. Per Container(40'HQ) 780 pieces -For detailed information,please contact your local Canadian Solar sales and technical representatives. ELECTRICAL DATA I NMOT* CS611 38OMS 385MS 390MS 395MS 40OMS 405MS TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 IN Specification Data Opt.Operating Voltage(Vmp)28.1 V 28.3V 28.4V 28.6V 28.8V 29.0V Temperature Coefficient(Pmax) -0.34%/*C Opt.Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Voc) -0.26%/oC Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/*C Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A •Under Nominal Module Operating Temperature(NMOT),irradiance of 800 WIm,spectrum AM 1.5, Nominal Module Operating Temperature 42±-3*C ambient temperature 20°C,wind speed I m/s. PARTNER SECTION ......................................................................................... The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.CSI Solar Co.,Ltd.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. ................................................................................................................... ...........I...................................................I...................................... ........I................................................I............................................................................................ CSI SOLAR(USA)CO.,LTD. June 2022 1 All rights reserved I PV Module Product Datasheet v1.5C25_F23_J2_NA IRONRIDGE Flush Mount System -m Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability Self-drilling screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear and black finish Clear and black finish Clear anodized finish Forms secure bonding Clamps & Grounding O UFOs Stopper Sleeves Grounding Lugs Microinverter Kits A — ' ` - .�. Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed Bonds modules to rails Low profile Bonds devices to rails • Single, universal size Sized to match modules Single tool installation Kit comes assembled • Clear and black finish Clear and black finish Mounts in any direction Listed to UL 2703 Attachments O FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install Twist-on Cap eases install Secure rail connections T& Square Bolt options • Wind-driven rain tested Wind-driven rain tested Slot for vertical adjusting Nut uses 7/16"socket • Mill and black finish Secures 3/a"or 1"conduit Clear and black finish Assembled and lubricated Resources ---- :_ Design Assistant NABCEP Certified Training -_ - Go from rough layout to fully �' Earn free continuing education credits, engineered system. For free. NABCEP while learning more about our systems. - Go to IronRidge.com/design � Go to IronRidge.com/training 0 2016 IronRidge,Inc.All rights reserved.Visit www.ironeidge.com or call 1-800-227-952!l for more information.Version 1.40 ,��_ ENPHASE. IQ8 and IQ8+ Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability Produce power even when the Enphase grid is down* More than one million cumulative hours of testing • Class II double-insulated Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. powered PV modules Microgrid-forming Complies with the latest advanced grid support** CERTIFIED Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to IQ8 Series IQ8 Series Microinverters are UL Listed as Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other `Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. "IQ8 and IQ8PIus supports split phase,240V IQ8SP-DS-0002-01-EN-US-2022-03-17 installations only. IQ8 and IQ8+ Microinverters INPUT DATA fDCI IQ8-60-2-US 1. Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range v 27-37 29-45 Operating range v 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage v 50 60 Max DC currentz[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' v 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit` 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to+600C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2022-03-17 Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUVIYNBAZLZVD5-_3_M35FHW Town of Southold April 1�8th, 4 Bud /�ding Department /`'`i E N®MENT Town Hall Annex at Mph ;L 54375 Main Road P.O. Box 1179 �" Southold, New York 11971-0959 ati Subject: Battery Energy Storage System and Roof-Mounted PV System at Evans Residence. Located at 1120 Willow Dr. Greenport, NY 11944 To Town of Southold: I hereby affirm and certify that, following comprehensive professional evaluations, the plans for the installation of both the Solar PV System and the Battery Energy Storage System (BESS) comply with the 2020 Residential Code of New York State, the 2020 Building Code of New York State, the 2020 Fire Code of New York State, the 2017 National Electric Code, ASCE 7-16, and other relevant industry standards and regulations. These certifications are provided in strict adherence to the governing regulations and standards-applicable to such installations. For the Solar PV System, it is my professional opinion that the subject plans comply with the aforementioned codes and standards. The structural framing of the existing roof has been evaluated to support the additional loads from solar panels, with deflection and stresses within allowable limits for wind pressures and snow loads specified in the codes. The mounting locations and methods indicat�d in the plans are deemed adequate, and the existing building and roof framing are structurally sufficient to support the solar panels. Regarding the Battery Energy Storage System (BESS), the proposed plans have undergone thorough scrutiny and are confirmed to align with requisite codes and standards. Utilizing Lithium Iron Phosphate technology, the BESS adheres to UL9540A standards to prevent thermal runaway. The enclosure design meets fire-resistant requirements outlined in the NYS Building Code. In my professional opinion, derived from site inspections and detailed analyses, both the proposed Solar PV System and the BESS, including the enclosure system, demonstrate structural adequacy to withstand associated reactions. Please feel free to contact me if you have any questions or require further clarification. Sincerely, ��pF NEUIjY Gennaro Anthony Giustra. P.E. CO o A Great Eastern Services, Inc. I_ PO Box 240 24 Harvey Rd 2 Riverhead, NY 11901 103443 Mobile: 631.235.0189 ARoss1oNP� Email: jerrygiustra@gmail.com Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUVIYNBAZLZVD5-_3_M35FHW L SCOPE OF WORK r ry r - r DELEMENT NERD LLC ,,'�,r�``�,,d'',� ',�i�� ,�,r�'vr''y'' .��'s''�.. ''�''�''����i��,/ �yyr"�r'' '` ��5'"r,��%� i%�:d''Pumi- ELEMENT ENERGY LLC TO INSTALL A 8 KWDC PV SYSTEM AND A 10 KW BATTERY ENERGY STORAGE SYSTEM AT EVANS RESIDENCE, , r, ✓ REVIEW BY J.M.NABCEP CERTIPIE LOCATED AT 1 120 WILLOW DR,GREENPORT, NY 1 1944. ` , fir. �� r � � s � 051 1 1 2-120 �✓'d,d'�° ✓'��! � rP� t'� ��f..e' ' ."sa�ar �'.v's�ar'✓'/.���+� ^,�a���r` ��,.� THE POWER GENERATED BY THE PV 5Y5TEM AND BATTERY ENERGY STORAGE SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. �r /'� �.�`�°°.�'' � � � ' � �,� ,�' REVISIONS r�'S� � � .i'3,.r, r,/' .7.�.^`J'�,'.fY� .dyf��' '� �✓''s.'�'i' �..r�.s �'',t'�',��'`>T'� DESCRIPTION DATE j rzFv SYSTEM RATING REV151ON 4/1612024 20 kW AC 5TC BATTERY ENERGY STORAGE SYSTEM 8 KW DC 5TC PV SYSTEM , J'.',y' v' /!.,•' !rJf '' ,+'v Gr02B (f/'� /C ' -�'+' °` F,r r`/ v ,'' '',` EQUIPMENT SUMMARY I UNIT OF SONNEN 50NNENCORE+ 20 KW BATTERY ENERGY STORAGE .r�, �/ '"j,�✓"'�ryi��4���/�r'd ei ht���'��{ �s f'Y+'. ,t�, .✓;s" ..ii,",''�'r;> r'`"'�. 20 CANADIAN SOLAR, CSGR-40OM5-HL WATT PV MODULES '' ' 20 ENPHA5E IQBPLU5-72-2-U5 MICRO INVERTERS � �/y � r/ snett re slao� I IRONRIDGE XR 100 MOUNTING SYSTEM �a v/ 5o Nrold ✓ SKEET INDEX , CONTRACTOR ;. >,�✓t/fir'' � .`l` ; ELEMENT ENERGY, LLC. PV-I COVER %// � i � ��� /f�f .� y�� � 7470 SOUND AVE PV-2 SITE PLAN MATTITUCK, NY 1 195 PV-3 PV PLAN PV-4 STRUCTURAL DETAILS PROJECT LOCATION LICENSE # G746 I-HI PV-5 BATTERY PLAN LICENSE# 52G89-ME PV-G ELECTRICAL DIAGRAM PV-7 LABELS GOVERNING CODES OF NEt�,r A O 2017 NATIONAL ELECTRICAL CODE. �2 2020 RESIDENTIAL CODE OF NEW YORK STATE. _ 2020 BUILDING CODE OF NEW YORK STATE. r o w FIR E RE CODE OF NEW YORK STATE to A5CE 7-1 G AND NFPA-70. UNDERWRITERS LABORATORIES(UQ STANDARDS ;034 0,34 05HA 29 CFR 19 10.2G9 '. �OAR043�P<C.� FESSIO GENERAL NOTES PROJECT NAME \1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT p THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE LLJ � HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK AGREE THE SAME. AERIAL VIEW � Z 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED } P W — APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP n 0 z INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION 0 O AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. , —J COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES _ 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO o O ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. JURISDICTION. 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR Z LU 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE �O � O_ WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS 2 lLJ _ p THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THI5 PROCEDURE AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION.THIS SHALL INCLUDE, BUT ARE NOT FROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, 5HEET NAME RESPONSIBILITY AND LIABILITY THERE AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 5. ALL STRUCTURAL STEEL SHALL BE FRO FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 SCAFFOLDING STAIRS, ETC.. AS WELL AS PERMANENT COVE SPECIFICATIONS. CONSTRUCTION. G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES*REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. DRAWING SCALE R CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBIS CREATED BY THIS 8.THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON S A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. N .T. . HALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. I AT THE COMPLETION OF WORK,THE SITE F CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY IS TO BE LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE EXTENSIONS TO THI5 PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF sliEEr NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. - EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS PV— I RESULT OF HI5 WORK. TAX MAP: 1000-040.00-02.00-006.008 Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUVIYNBAZLZVD5-_3_M35FHW LEGEND DESIGN 6 DRAFTING BY: EXISTING UTILITY METER MAIN SERVICE PANEL 1 2 I ELEMENTENERGY LL RE - VIEW 6 O5 I J.M.N2-129 CERTIFIED NEW PV SUB-PANELS 2 A/C DISCONNECT COMBINER INVERTERS -- GND ELECTRODE RfV151ON5 DE5CRIFTION DATE REV I-�PV MODULE REV15ION 411 G12024 A RACKING RAIL O ATTACHMENT POINT ---RAFTERS —ROOF PITCH ANGLE �SUNRUN METER a ®VENT rn OPLUMBING VENT 1 111 ®slcY LIGHT2 2— 104 ACCESS ROOF ®CHIMNEY p CONTRACTOR®COMPOSITE SHINGLES n ELEMENT ENERGY, LLC. GOOD CONDITION POTENTIAL SHADING ISSUES T 7470 SOUND AVE 7RIM/REMOVE AS NECESSARY ,LL0, MATTITUCK, NY 1 195 LICENSE# 674E I—HI LICENSE# 52G.59—ME OF NE I, G'Gso�� Y n IJ ARro SSIONP�. PROJECT NAME 0LU LU- U > 10, W Q 32'-GI' ACCESS ROOF XE55 R001� �n O z g w o o o n c D_ z jOED CV Lu — SHEET NAME 'NOTE SITE PLAN I.)THE ROOF SETBACK/PATHWAY SHALL NOT BE MAIN ELECTRICAL SERVICE PANEL REQUIRED TO ROOFS WHERE THE OPPOSITE OR XISTING ADJACENT ROOF IS ACCESS ROOF IN ACCORDANCE WITH R324.G.I EXCEPTION OF EW PV AC DISCONNECT DRAWING SCALE 2020 NYS RESIDENTIAL CODE. L'. XISTING UTILITY METER CONSTRUCTION NOTES 71-7 I I1 I/8" = I -011 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE EW BATTERY ENERGY STORAGE SYSTEM IN THE DETACHED SHED MANUFACTURER'S INSTALLATION INSTRUCTIONS.2.)ALL OUTDOOR EQUIPMENT SHALL BE 3.)ALL LOCATIONS AAKE APPROXIMATE (NTIGHT WITH MINIMUM NEMA 3R RATING. SHEET NUM6ER AND REQUIRE FIELD VERIFICATION. II-- 4.)THE BATTERY IS LOCATED INSIDE OF THE DETACHED SHED 50 IT DOES NOT NEED TO BE 2 PV-2 FIRE-RATED IN ACCORDANCE WITH R327 OF 2020 NY5 RESIDENTIAL CODE. TAX MAP: 1000-040.00-02.00-OOG.008 Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUV1YNBAZLZVD5-_3_M35FHW LEGEND DESIGN 4 DRAFTING BY: EXISTING UTILITY METER 21-1�n ELEMENT ENERGY LLC MAIN SERVICE PANEL 2 ' REVIEW BY J.M.NAECEP CERTIFIE \ ERNEW PV SUB—PANELS ^, 051 112-129 / A/C DISCONNECT COMBINER $ 0° INVERTERS B REVI51ON5 GND ELECTRODE ��0° , O DESCRIPTION DATE REV F—MPV MODULE REVISION 4/1612024 RACKING RAIL 2'-14 0 u_.... ?g0 q 4 O ATTACHMENT POINT ¢ 270° 0 O90°A ---RAFTERS �® 780°'S0°'20. r -*--ROOF PITCH ANGLE 59SUNRUN METER ®OJT ACCr.SSROOF OPLUMBING VENT ®SKY LIGHT ARRAY#2 ®CHIMNEY G MODULES CONTRACTOR COMPOSITE SHINGLES 290 PITCH ELEMENT ENERGY, LLC. ®GOOD CONDITION 2G I'AZIMUTH POTENTIAL SHADING ISSUES 7470 SOUND AVE aTRIM/REMOVE AS NECESSARY �-- I MATTITUCK, NY 1 195 LICENSE# G74G I-HI LICENSE# 52G89-ME ��OF NE�y y O e _ 1 BOA >03443 - R� ssil �`.'. PROJECT NAME -- rn az F AccEss RooF 3 O z OL ARRAY#I 14 MODULES c i 29° PITCH IE 9 91z 2G I'AZIMUTH i g0 L O D_ lu 71I..... I o Q p w > c\1 o LU — ® ® 5hEET NAME CONSTRUCTION SUMMARY- MAIN HOUSE -21 E15TING AISCOCTRJC PV PLAN (STING MAIN ELECTRICAL SERVICE PANEL (20)CANADIAN SOLAR, C5GR-40OM5-HL 400 WATT PV MODULES ® J(ISIING UTILITY METER (DIMENSIONS: G7.8"X 44.G"X 1.4") (20) ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS (G2)ATTACHMENT POINTS @ 72"O.C. MAX. EW BATTERY ENERGY STORAGE SYSTEM (248.3) LF IRONRIDGE XR100 MOUNTING SYSTEM. IN THE DETACHED SHED DRAWING 5CALE ROOF TYPE = A5PHALT SHINGLE(SINGLE LAYER) /QII = I I—oII CONSTRUCTION NOTES V 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. snEEr NUMBER 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. PV-3 4.)WALLS AND CEILING INSIDE THE BATTERY ENCLOSURE SHALL BE LMINATED WITH 5/8"TYPE X 5HEETROCK OR EQUIVALENT 5.)THE DOOR OF THE BATTERY ENCLOSURE SHALL BE 3G"WIDE MINIUMUM 20 MINUTE FIRE RATED DOOR. TAX MAP: 1 000-040.00-02.0O-OOG.O08 Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUV1YNBAZLZVD5-_3_M35FHW ITEM I DE5GRIPTION ARRAYS#1-2 LOAD CALCULATION ARRAY#I ARRAY#2 RB Rld a Beam/Board 2"X 8" D. FIR DESIGN 4 DRAFTING BY: ( Rafter 2"X G" D. FIR I G"O.C. ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 48.4 48.4 REVIEW BY J.M.NABCEP CERTIFIE P Pitch 29° 051 112-129 #OF MODULES 14 G (D) Deckm 5/8"PLYWOOD TOTAL MODULE WEIGHT(Lbs) G77.G 290.4 J Celllr Joist 2"X G" D. FIR I G"O.C. Collar TI REVISIONS TOTAL LENGTH OF RAIL(Ft) 173.8 74.5 Horizontal S an of DE5CRIPTION DATE REV REV15ION 4/16/2024 A RAIL WEIGHT PER FOOT(Lbs) O.G8 0.G8 TOTAL RAIL WEIGHT(Lbs) 115.2 50.7 (R) (RB) #Of 5TRANDOFF5 42 20 WEIGHT PER 5TRANDOFF(Lbs) 2 2 (D) TOTAL STANDOFF WEIGHT(Lbs) 84 40 TOTAL ARRAY WEIGHT(Lbs) 679.8 381.1 POINT LOAD(Lbs) 20.0 19.1 CONTRACTOR TOTAL ARRAY AREA(Sal Ft) 299.7 128.5 ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lb5/5cl Ft) 2.9 3.0 ( ) 7470 SOUND AVE MATTITLICK, NY 1 195 WIND DESIGN SUBJECT TO DAMAGE FROM LICENSE# G74G I-HI GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR MEAN SNOW DESIGN DESIGN UNDERLAYMENT FREEZING ANNUAL (C) LICENSE# 52G89-ME Frost HAZARD59 LOAD* Speed" Topographic Special Windborne CATEGORY{ Weathering' line Termite' TEMP` REQUIREDn INDEXi TEMP) (mph) effects wind region' debris zone'" depthb MOD TO FEMA OF NEjy 20 140 NO NO NO B SEVERE 3 FT HEAVY 15"F YES ZONE X 599 5 1"F /P(�gQ A G/GYO� MANUAL J DE51GN CRITERIA Indoor (H Elevation Latitude Winter Summer Altitude correction factor de5lgn Design temperature cooling Heating temperature � _ t ffl -i heating cooling tempera difference (J) y� -i:, e`tj ture o 103aa3 108 FT 41"N 15"F 8G°F 1.00 70"F 75"F 55°F AROFESSIONP� Wind Wind Cooling temperature difference velocity velocity Coincident Daily range Winter Summer humidity - heating cooling wet bulb humidity ROOF FRAMING DETAIL n PROJECT NAME 1 5°F 15 MPH 7.5 MPH 72-F MEDIUM(M) 40% 32 GR @50%RH 0 LU I I I I I i W For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. w U a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth N lL1 Cl, _ strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as MODULE MOUNTING CLAMP N Q determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. -�: } b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction SOLAR MODULE Q L(LJ 0 shall fill in the frost line depth column with the minimum depth of footing below finish grade. C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. STAINLESS STEEL 3/8" O _ I 0/ d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined BOLT AND NUT C) 0 0_ on a site specific basis in accordance with Section R301.2.1.4. w z Z e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York O W State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also � N � see Figure R301.2(1).] NRIDGE ALUMINUM RAIL W _ (� f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. ALUMINUM"L"BRACKET CZ 9. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: ALUMINUM FLASHING I.The accompanying Flood Insurance Rate Map(FIRM), ShEET AM ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. ASPHALT SHINGLE ROOF STRUCTURAL DETAIL h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5/I x 6"STAINLESS I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WITH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32"F)" 2 I/2"MIN THREAD PENETRATION SEALED j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method WITH GEOCEL 4500 (Base 32°F)." (EQUIVALENT OR BETTER) DRAWING SCALE k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table.I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with 1^I V . IT .5. "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or lb from ACCA Manual J or established criteria determined by the SHEET NUMBER jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet Sites at M Q\/ elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. MOUNTING DETAIL 2 1 V —4 (') See Figure R301.2(4)B. TAX MAP: 1000-040.00-02.00-OOG.008 Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUVIYNBAZLZVD5-_3_M35FHW LEGEND DESIGN 4 DRAFTING BY: �DGSTING UTI JTY METER ELEMENT ENERGY IMAIN SERVICE PANEL REVIEW BY 1 J.M. . 2 FIE-129 GERTI NEW PV SUB-PANELS A/C DISCONNECT COMBINER INVERTERS Q REVISIONS GND ELECTRODE -7 - 8_2 DESCRIPTION DATE REV PV MODULE REVISION 4/16/2024 q RACKING RAIL O ATTACHMENT POINT ---RAFTERS IIN z aim., PROOF PITCH ANGLE '.,, gak y. ?4,. '�+_ � 11" SUNRUN METER ®VENT 6 OPLUMBING VENT ®SKY LIGHT ® RACTOR CHIMNEY CONT ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD CONDITION POTENTIAL SHADING ISSUES » 7470 50UND AVE TRIM/REMOVE AS NECESSARY 6 — 61 - `J MATTITUCK, NY 1195 LICENSE # G74G I-HI LICENSE# 52G89-ME 1 0 4 of NEWJ- P oA O Gj'� g ,r-G,Gs 6) _ 5» * �; 4 �03443 AROFESSIONP� 1 ) 50NNEN 50NNENCORE 20KW 15E55 UNIT PROJECT NAME O w w W z IZ (3) } Lu C) _ (n DC () 0 Z g w Li 0 oL __ O z CONSTRUCTION SUMMARY z w (1) UNIT OF 5ONNEN 5ONNENCORE+ 20KWH BATTERY O Q w ENERGY STORAGE SYSTEM p W N (DIMENSIONS: 27"X IX 14") IN DETACHED 5HED WITH — CLEARANCE OF THREE-FEET IN FRONT OF THE BATTERY CONSTRUCTION NOTES 51 NAME 1.) ALL EQUIPMENT 5HALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER5 INSTALLATION INSTRUCTIONS. BATTERY PLAN 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.)THE BATTERY 15 LOCATED IN51DE OF THE DETACHED DRAWING SCALE SHED 50 IT DOES NOT NEED TO BE FIRE-RATED IN ACCORDANCE WITH R327 OF 2020 NY5 RESIDENTIAL 1 1 G11 = 1 1_011 CODE. [PARTIAL SHED FLOOR PLAN FOR BATTERY ENERGY STORAGE SYSTEM] 5.)TH15 BE55 15 TO BE INSTALLED IN51DE OF DETACHED SHED. G.)TH15 SYSTEM 15 COMPLIANT WITH THE SECTION R327 5HEET NUMBER OF THE INTERNATIONAL RESIDENTIAL CODE, A5 AMENDED BY THE NEW YORK STATE UNIFORM CODE PV-5 TAX MAP: 1000-040.00-02.00-OOG.008 Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUVIYNBAZLZVD5--3-M35FHW ELECTRICAL NOTES GENERAL NOTES DE51GN C DRAFTING BY: 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND 1.)THE BE55 PROVIDES MONITORING AND ELEMENT ENERGY LLC 50LARARRAYONMAIN HOU5E3.GkW LABELED FOR ITS APPLICATION. BALANCING CELL VOLTAGES,CURRENTS, REVIEW BY J.M.NABCEP CERTIFIE -� (9)CANADIAN 50iPR C56R-0OOM5-11L40OW PV MODULES 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND TEMPERATURES WITHIN THE MANUFACTURER'S 05 1 1 1 2-129 i (p STRINGS OF(9)MICRO-INVERTERS AND 909C WET ENVIRONMENT. SPECIFICATION THROUGH WEB AND MOBILE 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON APPLICATIONS. -- STRING#2 ROOFTOPS SHALL BE ROUTED DIRECTLY 2.)THE HEAT DETECTOR OR HEAT ALARM SHALL BE REVISIONS - - - - - - fIWHASf TO,AND LOCATED AS CLO5E AS POSSIBLE TO THE INSTALLED AND INTERCONNECTED WITH SMOKE MODULE INFO r ---------- aRANCN DESCRIPTION DATE REV - - - - - - - - TERMINATOR NEAREST RIDGE,HIP,OR VALLEY. ALARM AND THE BE55 SYSTEM SHALL TRAN5M IT AN MODEL PART NUMBER QCELL:Q.PEAK DUO BLK ML-G I O+40OW ___________ _ __ ___ _ MIS 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ALARM SIGNAL VIA MOBILE PORTAL OR THE SMOKE �151ON 411 G12024 A VOC 3G.8 V - - - ELECTRICAL EQUIPMENT SHALL AND/OR HEAT ALARM/DETECTOR IF POTENTIALLY VMP 30.8 V I COMPLY WITH NEC 110.2G. HAZARDOUS TEMPERATURES OR OTHER CONDITIONS 15C 13.85 A j 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SUCH AS SHORT CIRCUITS,OVER VOLTAGE OR SYSTEMS.CONTRACTOR SHALL UNDER VOLTAGE ARE DETECTED. IMP 12.99 A j FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS 3.)CONDUIT AND CONDUCTORS SPECIFICATIONS 5TC RATING 400 W j AND ACE550RIE5 TO FULFILL ARE BASED ON MINIMUM CODE REQUIREMENTS AND FTC RATING 299 W 1 APPLICABLE CODES AND STANDARDS. ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED 1 G.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND BY FIELD CONDITIONS. SOLAR,ARRAY ON MAIN HOUSE 4.4 kW 1 CONDUITS ARE NOT SPECIFIED, (I I)CANADIAN SOLAR C56R-40OM5-HL 40OW PV MODULES I THE CONTRACTOR SHALL 512E THEM ACCORDINGLY. (I)STRINGS OF(1 I)MICRO-INVERTERS 1 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY AC DISCONNECT LABELED AND READILY VISIBLE. CONTRACTOR 1332 5.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN STRING#I _ _ _ „ "° MODULE FRAME AND MODULE ELEMENT ENERGY, LLC. ------- -- - - - - - - - °„ SUPPORT RAIL,PER THE GROUNDING CLIP 7470 50UND AVE MANUFACTURER'5INSTRUCTION. MATTITUCK, NY 1 195 i --- - - - 1 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS LICENSE# G74G I-HI I 1 M¢RD.INVERrzR I PCO"AB1N6RBO`' COPPER G.E.C.VIA WEEK LUG fNH,Asc BRANrn cRu,°��T*P'� - E"P"'SE 1eHR11s'2-�-'� "`""`"""� - • - OR IL.5CO G13L-4DBT LAY-IN LUG. LICENSE# 52G59-ME 24.vs,1.21 A l G. =zsv a ..G. OET,. I 1 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15 uL eff. I 1 (po5Mve/negative) _ I ; I OR or- NE I I 1 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND w L----------------------- --------� j SHALL COMPLY WITH NEC G90.35. �P�� O A G y0 I I.)THE INSTALLATION COMPLIES WITH R327 ENERGY _�� /Gs��p� To unuTrcvD I I STORAGE SYSTEMS. f to 1.2.)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT N B,-D1RecrlGNu- I I MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD Lu CONDITIONS. -PHASE,240V O u w M ER 2 1 (P � �y ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT T INOA y 03443 I I I I MINIMUM 7/8"ABOVE ROOF WITH PROPER JUNCTION BOX AT "`°"'•"'°" ESSI ROFONP� ( I K I I A=or"o�c`souw - EACH END. I I I 1 PROJECT NAME I = LU I I 20^ T OTHER LOADS lLl -A tu (N)200A AC aaA D I C) _ L ------ BAG.-UPLOADPANEL CONNECTIONS I I + 0,ozwcRnnNu j Nu"„R.rz .»,4c* 4/ U J O Z N B 11 O I L----------\-----------------------� i O � J o n § O S O N N E N '^ MAIN 5ERVICE PANEL II.J O z 'SYSTEM SPECIFICATIONS 4 NOTES' LU ------------------------------- ° .,.w O � Q CV � TOTAL SYSTEM SIZE:8 kW i G ^K LLI O MODULES: (20)CANADIAN SOLAR,C5GR-40OM5-HL 40OW PV MODULES Li 1 I I I ELES RODC 5U5 DING INVERTERS: (20)ENPHA5E IQSPLU5-72-2-U5 MICRO-INVERTERS SONNENCORE+ESS 1 �_-___-J J j EIECTRopEs sreM (20)MODULES INSTALLED ON MAIN HOUSE SCORE- E+ 20kWh/240V 20 SHEET NAME WIRE 4 CONDUIT SCHEDULE 3 LINE D I A. STARTING TEMPERATURE 51AKIING MAXIMUM MAX. CONDUIT FILL ADJUSTED CURRENT CURRENT CIRCUIT CONDUCTOR CONDUCTOR CONDUCTOR GROUND AMBIENT ESTIMATED OLTAGE DRO ALLOWABLE CORRECTION CIRCUIT I.D.# CIRCUIT ORIGIN DESTINATION SIZE CONDUCTORS QUANTITY DERATE INSULATION GROUND SIZE QUANTITY CONDUIT SIZE TYPE CONDUIT TYPE TEMP. D15TANCE (%) AMPACITY FACTOR CONDUCTOR APPLIED APPLIEDTO PER POLE (310.15(13)(3)) 3 10.15(B)(I G)310.15(5)(1 6) AMPACITY CONDUCTOR S CONDUCTOROR S IN RACEWAY IN RACEWAY DRAWING SCALE I MICRO-INVERTER AWG#12 1 4 0.8 U5E-2/PV-WIRE AWG#8 I BARE CU FMT 55QC 1 10 FT. 1.59 30 0.84 20.I G 13.31 1 G.G4 AG 2 COMBINER BOX AWG#8 I 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 5CH 40 45QC 50 FT. 0.9G 55 0.9G 52.80 10.89 13.G 1 N •T S. 3 AC DISCONNECT POI AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 5CH 40 45QC 30 FT. 0.04 75 0.9G 72.00 10.55 13.G 1 4 PANFI BATTERY AWG#8 1 3 1 THWN-2 AWG#8 iEll THWN-2 CU PVC 5CH 40 45QC 10 FT. 0.55 55 0.9G 52.80 NA NA 5 BATTERY POI AWG#81 3 1 THWN-2 AWG#8 THWN-2 CU PVC 5CH 40 45QC, 10 FT. 0.14 55 0.9G 52.50 13.31 1 G.G4 SHEET NUMBER TAX MAP: 1000-040.00-02.00-OOG.008 Zoho Sign Document ID:2A768FFA-VF5KKPOE-6PBVHOXOKCCUVIYNBAZLZVD5-_3_M35FHW SERVICE METER O O � DESIGN E DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGY LLC REVIEW BY J.M.NABCEP CERTIFIE Q} 1RP11 ('STEM% PHOTOVOLTAIC � � e � � ( 1 ) ALL LABEL SHALL BE INSTALLED IN 05/12129 ® � EQlJ1PPEDINITHSOLAR-BREAKER It ACCORDANCE WITH THE 2017 NEC - REV15ION5 '1' ► D;,` IUT�I~.IW ® a• e REQUIREMENTS. DESCRIPTION DATE REV OPERATING CURRENT A (2) ALL LOCATIONS ARE APPROXIMATE AND REVI5ION 41I6/2024 A MAX SYSJEM SOLAR AC LOAD CENTER- OUTSIDE Fc ° °CSHORT CIRCUIT CURRENT r REQUIRE FIELD VERIFICATION. tVEXW1 'IDI; W (3) LABELS, WARNINGS) AND MARKING O TURN RAPID SHUTDOWN SWITCH TO Og SHALL BE IN ACCORDANCE WITH NEC THE`OFF POSITION TO SHUTDOWN 1 1 0.2 1 (B). PV SYSTEM AN REDUCE 3 CAUTION sHocKHAZARo Ll 1NT"� AC DISCONNECT ; PFWERTROM TOHEIU o� `SUPPLIED (4) THE MATERIAL USED FOR MARKING DISCONNECTS LOCATED AS SHOWN MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER- INSIDE 20 ® "�'� COMPLIANCE WITH NEC 1 1 0.2 1 (B)(3). C°NTRACT°R PAD ELEMENT ENERGY, LLC. O N! VE �'Y"Y I �' SHALLEB LABELED INS AL ED IN ONDUCTORS MATTTGUCKO NY IA95 THIS EQUIPMENT FED SYMULTIPLE DUAL POWER SUPPLY SOURCES.TOTAL RATING OF ALL �� COMPLIANCE WITH NEC G90.3 1 LICENSE# 67461-Fil OVERCURRENT DEVICES,EXCLUDING SOURCES:UTILITY GRID LICENSE# 52689-ME MAIN SUPPLY OVERCURRENT AND PV SOLAR DEVXE,SHAD.NOT EXCEED �ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING n�aPA�crTYOFeussa of NEl�y y THIS SERVICE METER h a IS ALSO SERVED BY A ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM Z 2 TERMINALS ON THE LINE AND COMBINER PANEL t N� t; aaYS ty` 10 3 LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS q 344 CONDUIT - OUTSIDE BUILDING IN THE OPEN POSITION RoFESS►oNP� ® N-9 -PROJECT NAME R W LLl DUAL POWER SUPPLY w U SOURCES:UTILITY GRID AND T } W C) PV SOLAR ELECTRIC SYSTEM' — i�� r C) MAIN SERVICE PANEL- OUTSIDELU 0 CZ O 02 03 �5 =' CLIIA ® O SOLAR ELECTRIC SYSTEM CONNECTED; LU Z �` • ® z N � n- LU Q O aJ G 1 • • o w — c� MAIN SERVICE PANEL- INSIDE POWER SOURCE I OUTPUT CONNECTION t 5NEET NAME DO NOT RELOCATE THIS 4 7 OVERCURRENT DEVICE i ......................................_............... ...._....... SIGNAGE AC DISCONNECT/BREAKER DRAWING 5CALE OOO N .T.S. 5HEET NUMBER PV-7 TAX MAP: 1000-040.00-02.00-OOG.008 H r S <" `� . Z. s .o , n e n ._k DEC - 2 22 Engineering Design Tech Specs - sonnenCore+ The sonnenCore+is a stackable indoor solution that offers up to 60 kWh of battery capacity.The sleek design combines smart energy management with the safe and long-lasting batteries to efficiently manage solar energy usage throughout the day,store excess solar power for use at night and provide reliable backup power during planned and unplanned power outages. Model number SCORE-P10(10 kWh) SCORE-P20(20 kWh) Weight per unit(approximate) 353 Ibs(160 kg) 525 Ibs(238 kg) Dimensions per unit W"/H"/D" 27/69.5 114 (adjustable height from ground) 27/71.5 114(with legs elevated) Grid integration AC coupled 32°F-113°F(0°C-45°C) Ambient temperature 41°F-95°F(5°C to 35°C)(MAX power) Applications Time-of-use,Solar self-consumption, Emergency backup power Stacked specifications Number of stacked units 1 2 3 Usable capacity 10 kWh/20 kWh 20 kWh/4O kWh 30 kWh/6O kWh (SCORE-P10/SCORE-P20) Nominal power rating 4.8 kVA 9.6 kVA 14.4 kVA (Grid-tied output at 104°F) Inverter efficiency 94.4%peak Max Round-trip efficiency' 85.8%peak On-grid pass through 35 A 200 A 200 A (requires AC Connections module) (requires AC Connections module) External devices and Installation restrictions None None configurations complying with Rule 21 may be required for CA Off-grid specifications No disconnect/continuous operation 0 A-25 A 0 A-50 A 0 A-75 A 5s to disconnect 30 A-36 A 60 A-72 A 90 A-108 A 450ms to disconnect 36 A-50 A 72 A-100 A 108 A-150 A Immediate shutdown >50 A >100 A >150 A 0 sonnen General specifications Measurements System cooling Natural convection Communication ports Ethernet - Front view Side view Communication protocols/ API available to select partners Control p 27.08 in[689.9 mm] 1185 in[35i:8 mm] "-Seismic rating IEEE 693 Noise emission <25 dB Total harmonic distortion <5% Max operation altitude 6562 ft(2000 m) 107 Maximum recommended PV 6 kVA inverter per sonnen system' E Smallest room volume 15 m' m SCORE-P20 12. C4 10 rn � � u Compliance information Certifications UL1741,UL1741SA,UL1973,UL9540,UN38.3 Grid code IEEE 1547.1,Prepa 2013 Emissions FCC Part 15 Class B(inverter) IEC 61000-4-2:2008,IEC 61000-4-3:2010, Immunity IEC 61000-4-4:2012,IEC 61000-4-5:2014, IEC 61000-4-6:2013,IEC 61000-4-8:2009 g Transient protection IEEE C62.41 Class B 10 year or 10,000 cycle system warranty- Warranty' includes inverter,battery modules,cabinet pp and components Enclosure rating IP30 o°pLr•Oq Battery specification ® 0 84 LT• Nominal DC voltage 102 VDC DC battery input voltage 96-112 VDC Max charge current 39.99 A per module Cell discharge' 5 kWh with 100%DoD Cell chemistry Lithium iron phosphate Over-current Protection Fuse protection We reserve the right to make technical changes.The values,outputs,other technical data,images,and diagrams in this prospectus and in data sheets,advertisements,and other promotional documents are approximate guidelines in all cases where they have not been identified as binding. 1 Maximum round trip efficiency shown is calculated using the single cycle round trip efficiency(SCRTE)formula used by SGIP administration in the State of California,as of the date of publication of this Spec Sheet. 2 In off-grid mode,the battery has a maximum charge limitation of 4.48 kW for 1 system,8.3 kW for a 2 stack system and 11.8 kW for a 3 stack system.In off-grid mode,exceeding these limits(accounting for load)will cause the microgrid to fail. 3 Please observe our applicable warranty conditions. 4 The sM4 battery modules are 5.5kWh in total capacity and represent 5kWh of usable capacity per module. 5 Based on full system AC/AC RTE"round-trip efficiency"at ambient temperature of 25'C(77'F),beginning of life in off-grid mode.Test conducted by sonnen Inc.R&D.Backup data available. Design Considerations Detailed round-trip efficiency ranges Round-trip efficiency of the entire sonnen system varies depending on charge/discharge power levels with an expected efficiency range shown below.The"Symmetric"curve within the range shows the efficiency when charge and discharge rates are equal.The upper and lower limits indicate the operating region of the system based on variations of those charging and discharging rates. 10kWh Roundtrip Efficiency(RTE)operating range 20kWh Roundtrip Efficiency(RTE)operating range so 80 A: i I W 70 I I jI __I Syrnm4rdcal �LU 70 i + I i Smmtrical ITLmel tLw/er 60 —upper - Upper 60 50 So ; 0 20 40 60 So 100 120 0 20 40 60 SO 100 120 Power level(%) Power Level(%) Single Line Diagram for System Design Below is an overview of the design layout for a single sonnenCore+ system with a protected loads panel for backup power. Specific project design consultation for custom installations is available through sonnen Applications Engineering at design@sonnen-batterie.com. PM J ❑ I I ----- r I r_— I I I I I I I w YMM — L__J L__J I I I �---- L-----------I L—J F 7Pvm k& I I Notes: L J 1.Service meter 2.Home main loads panel 3.sonnenCore+ 4.Protected loads subpanel S.Optional PV inverter Stacked sonnenCore+ Spec and Design The sonnenCore+ systems are designed to be stackable up to a maximum of three units per site installation depending on local utility rules and upon the recommentations of a licensed and qualified installer. Single Line Diagram-Stacked System Design NOTES: DIMM=A Sur= 1. 200A rated fused disconnect with 200A fuses(optional) V°AWCsxnav�s 2. 200A current transformer 3. AC connections module 4. 100A rated square-D panel,HOM612L100SCP or equivalent 5. sonnenCore+BESS 6. 200A electrical load panel 7. 60A current transformer 8. PV solar tamsrI— —————— a I 1 ` I oMAAGKC "`°or°rtrnts'ma"` I 130A3D J3M Ii I30A 7➢ I r----- -------, I I I I I oAvic rre L—— —— ————————J I I xanvuomo IdDA14 1 I I I s I I uw �mmwms rkr — -- I u u r—————— --� I I I I 4MZP 1tlAa )wAn aaANu elc ftmr I I I csw ow L-- -- --------J Mh3P CWTACM 1dANU L-------------3 tUAWC E(t �-- waxen r-- ------� NOA`A I ANC 9.RNCF 0= r---� I ca I I a I General notes I I I I I L— --- ------J Drawing is for reference only,and is not reflective I N am roAns of actual wire penetrations I I Verify proper grounding per National Electrical L---J Code(NEC)requirements All electrical equipment shall comply with the working clearance requirements per NEC All electrical work shall comply with the NEC AC connections module specifications AC connections module critical components Dimensions W"/H"/D" 16.3/36/6.1 Weight 67 Ibs(30 kg) Meter ° Passthrough rating 200 A Contactor Voltage 120/240 V Short-circuit current 10 KA with circuit breakers _ O rating Transition Open transition("Break before Automatic make") Transfer Enclosure Type 1 indoor Switch Certification UL1008 O O �— o LEDs Notes: Knockouts for cables must be made by installer. Consumption CTs are included. 0 Breaker sonnen Inc. ,� o 1578 Litton Dr,Stone Mountain,GA 30083 (310)853-2404 ° 0 sonnen A i -1 1 s o n n e n Especificaciones tecnicas de diseno de ingenieria: sonnenCore+ sonnenCore+es una soluci6n apilable para interiores que ofrece hasta 60 kWh de capacidad de bateria.Su elegante diseno combina la gesti6n inteligente de la energia con las baterias mas seguras y duraderas para gestionar eficientemente el consumo de energia solar a to largo del dia,almacenar el exceso de energia solar para su consumo por la noche y proporcionar energia de reserva fiable durante los cortes de energia planificados y no planificados. N6mero de modelo SCORE-P10(10 kWh) SCORE-P20(20 kWh) Peso(aproximado)por unidad 353 lb(160 kg) 525 lb(238 kg) Dimensiones por unidad An./AI./P. 27/69,5/14 en pulgadas (altura ajustable desde el suelo) 27/71,5/14(con las patas elevadas) Integraci6n con la red electrica Acoplado para corriente alterna Temperatura ambiente 32°F-113 T(0°C-45°C) 41 T-95°F(5°C a 35°C)(potencia MAX.) Aplicaciones Tiempo de uso,autoconsumo de energia solar, Energia de reserva de emergencia Especificaciones de los sistemas apilados N6mero de unidades apiladas 1 2 3 capacidad de use 10 kWh/20 kWh 20 kWh/40 kWh 30 kWh/60 kWh (SCORE-P10/SCORE-P20) Potencia nominal (salida conectada a la red electrica a 4,8 kW 9,6 kW 14,4 kW 104 T) Eficiencia del inversor 94,4%m6ximo Eficiencia max.de ida y vuelta' 85,8%maximo 200 A 200 A Corriente pasante de la red 35 A (requiere m6dulo de conexiones de (requiere m6dulo de conexiones corriente alterna) de corriente alterna) Pueden ser necesarios dispositivos Restricciones de instalaci6n Ninguna Ninguna externos y configuraciones que cumplan la Norma 21 para corriente alterna Especificaciones fuera de la red electrica Sin desconexi6n/funcionamiento continuo O A-25 A O A-50 A 0 A-75 A 5 s para desconectar 30 A-36 A 60 A-72 A 90 A-108 A 450 ms para desconectar 36 A-50 A 72 A-100 A 108 A-150 A Apagado inmediato >50 A >100 A >150 A 0 sonnen Especificaciones generales Mediciones Enfriamiento del sistema Conveccion natural Puertos de comunicaciones Ethernet Front view Side view Protocolos de comunicaciones/ API dis onible para socios selectos Control P p -27.'08 in"(689 9 mm] 1185 in[3518 mm] Clasificaci6n sismica IEEE 693 Emisi6n de ruidos <25 dB Distorsi6n arm6nica total <5 Altitud de funcionamiento max. 6562 ft(2000 m) wrn.n FOI Inversora fotovoltaica maxima 6 kVA E recomendada por sistema sonnen' E Menor volumen de sala G M. 12,15 m' SCORE-P20 N: u Informacion sobre cumplimiento Certificaciones UL1741,UL1741SA,UL1973,UL9540,UN38.3 C6digo de red electrica IEEE 1547,1741 SA,Prepa 2013 Emisiones FCC Parte 15 Clase B(inversor) IEC 61000-4-2:2008,IEC 61000-4-3:2010, Inmunidad IEC 610 0 0-4-4:2012,IEC 61000-4-5:2014, IEC 61000-4-6:2013,IEC 61000-4-8:2009 Protecci6n contra IEEE C62.41 Clase B corrientes transitorias Garantia del sistema de 10 anos o "oo Garantia' 10 000 ciclos:incluye inversor,mbdulos de �.0 baterias,gabinete y componentes do; Clasificaci6n de la carcasa IP30 ar" Especificaciones de las baterias ON Voltaje nominal de 102 V CC corriente continua Voltaje de entrada de 96-112 V CC baterias de CC Corriente de carga max. 39,99 A por modulo Descarga de celda' S kWh con 100%de profundidad de descarga Composici6n quimica de Litio ferrofosfato las celdas Protecci6n contra Protecci6n de fusible sobrecorriente Nos reservamos el derecho a introducir modificaciones tecnicas.Los valores,las salidas,otros datos tecnicos,las imagenes y los diagramas de este folleto y de las fichas t@cnicas,los anuncics y demas documentos promocionales son orientativos en todos los casos en qua no se han identificado como vinculantes. 1 La eficiencia maxima de ida y vuelta mostrada se calcula utilizando la formula de eficiencia de ida y vuelta en ciclo unico(SCRTE)utilizada por la administracion de SGIP en el Estado de California,en la fecha de publicacibn de esta hoja de especificaciones. 2 En modo fuera de la red electrica,la bateria tiene una limitaci6n de carga maxima de 4,48 kW para 1 sistema,8,3 kW para un sistema de 2 apilamientos y 11,8 kW para un sistema de 3 apilamientos. 3 Tenga en cuenta nuestras condiciones de garantia aplicables. 4 Los mbdulos de bateria sM4 tienen una capacidad total de 5,5 kWh y representan 5 kWh de capacidad de use por modulo. 5 Basado en la"eficiencia de ida y vuelta"RTE de CA/CA del sistema completo a una temperatura ambiente de 25'C(77 T),al comienzo de la vida Gtil en modo fuera de la red eldctrica.Prueba realizada por I+D de sonnen Inc.Datos de respaldo disponibles. Consideraciones sobre el diseno Rango detallado de eficiencia de ida y vuelta' La eficiencia de ida y vuelta de todo el sistema sonnen varia en funcion de los niveles de potencia de carga/descarga,con un rango de eficiencia esperado que se muestra a continuacion. La curva "simetrica"dentro del rango muestra la eficiencia cuando las tasas de carga y descarga son iguales. Los limites superior e inferior indican la region de funcionamiento del sistema en funcion de las variaciones de esas tasas de carga y descarga. Rango de operacibn de eficiencia Rango de operation de eficiencia de ida y vuelta(RTE)de 10 kWh de ida y vuelta(RTE)de 20 kWh 6ro i +——� eo -- — - -- —+----'— �-- - --- W70 -- --_-}-- �Simetrico W 70 ----- --' - -a F- -- - ---- ;------ ..t..Simetrico -�Bajar � � ^V l i --�-Bajar -0-Su 6rieur i P i I -f-Supeneur 60 •- 60 I I I i 50 __._-._.....�J 50 0 20 40 60 60 100 120 0 20 40 60 60 100 120 Nivel de potencia M Nivel de potencia C%) Diagrama de linea unica del diseno del sistema A continuacion,se muestra un esquema general del diseno de un sistema sonnenCore+ con un panel de cargas protegidas para la energia de reserva.Si tiene consultas especificas sobre el diseno del proyecto para instalaciones personalizadas, pbngase en contacto con el area de Ingenieria de Aplicaciones de sonnen en design@sonnen-batterie.com r I I PPIr»B=UMSPAM V= -n- F)XIV M I I l —1m— I r__ I I I I I I PVvM ` I I L--J L--J I ` F �— ---� L---------- L_J I I l I— —JwMkh I I I I Notas: L J 1.Medidor de servicio 2.Home panel de cargas principales 3.sonnenCore+ 4.Subpanel de cargas protegidas 5.Inversor fotovoltaico optional Especificaciones y diseno de sistemas apilados sonnenCore+ Los sistemas sonnenCore+ estan disenados para poder apilarse hasta un maximo de tres unidades por instalaci6n,en funci6n de las normas de las empresas de electricidad locales y de las recomendaciones de un instalador autorizado y cualificado. Diagrama de linea 6nica del diseno del sistema apilado Notas: tw°°MuaG�mAsrAv� Desconexi6n con fusible nominal de 200A con fusibles de 200A(opcional) +AMG�au= Transformador de corriente de 200A M6dulo de conexiones de CA Panel D cuadrado de 100A,HOM612L100SCP o equivalente sonnenCore+BESS Panel de carga electrica de 200A Transformador de corriente de 60A = Solar fotovoltaica A fiID.9r PAlm M ;WAVA wAM�MQ QBIE I ` I 1PA Ai[L ALm.WIEiRW--- I �wA7P )a°AlP I]6A2P I r----- -------, I I I i I I I —AM= I--- --------J I I -- �xmAnPomo I awxrs �I I 1 I I I � I I I I I I I I ,�onm )wAm )wAxP i i I 2,8AW° KC a°o L-- -- --------J i 1MA3PC°MrA= S°A'MS L—————————————J wsaua r-- i I Awesavraurae —� Notas generates: I I I j L— --- ------� El dibujo es solo para referencia y no es reflexive I M =MMLCM de penetraciones realer de alambre. Verifique la conexi6n a tierra adecuada segOn National L———J Electrical Requisitos del c6digo(NEC). Todo el material electrico debera cumplir con el requisitos de autorizaci6n de trabajo segOn NEC. Todos los trabajos el6ctricos deberan cumplir con el NEC. Especificaciones del m6dulo de Componentes criticos del m6dulo de conexiones conexiones de CA de CA Dimensiones An./AI./P. 16,3/36/6,1 en pulgadas Mostrador ° Peso 67 Ib(30 kg) Clasificaci6n de la 200 A Contactor corriente pasante Voltaje 120/240 V Clasificaci6n de corrien- 10 KA con disyuntores to de cortocircuito Interrupter de transferencia Transici6n Transici6n abierta("Break before automatica make") O O Recinto Tipo 1.interior LEDs Certificaci6n UL1008 Notas: El instalador debe realizar los orificios para los cables. ° Se incluyen los transformadores de corriente(CT)de consumo. Disyuntor sonnen Inc. ° 1578 Litton Dr,Stone Mountain,GA 30083 ° (310)853-2404 0 • 0080 002 �.; O_ O O a a y P 1, sonnen 1 Conception technique Cahier des charges technique - sonnenCore+ Le syst6me sonnenCore+est une solution empilable d'int6rieur off rant une capacit6 de batterie aIlant jusqu'6 60 kWh.Le design 6pur6 associe une gestion intelligente de 1'6nergie aux batteries les plus s6curitaires et les plus durables,afin de g6rer efficacement la consommation d'6nergie solaire en journ6e,stocker I'exc6s d'6nergie solaire pour un usage durant la nuit et fournir une alimentation d'urgence fiable durant les coupures de courant pr6vues et impr6vues. Num6ro de module SCORE-P10(10 kWh) SCORE-P20(20 kWh) Poids unite(approximatif) 160 kg(353 lb) 238 kg(525 lb) Dimensions unite L po/H po/P 27/69,5/14 Po(hauteur reglable a partir du sot) 27/715/14(avec les jambes sur6lev6es) Int6gration au r6seau Syst6me coupl6 c.a. Temperature ambiante 32T8113°F(0°Ca45°C) 41°F a 95°F(5°C a 35°C)(puissance MAX) Applications P6riode d'utilisation,autoconsommation solaire Alimentation de secours Sp6cifications empil6es Nombre d'unit6s empil6es 1 2 3 Capacit6 utile (SCORE-P10/SCORE-P20) 10 kWh/20 kWh 20 kWh/40 kWh 30 kWh/60 kWh Puissance nominale (production raccord6e au r6seau a 40°C 4,8 kW 9,6 kW 14,4 kW [104"F]) Rendement de I'onduleur Pointe de 94,4 Efficacit6 aller-retour maximum' Pointe de 85,8 Capacit6 nominate de circulation sur 35 A 200 A 200 A r6seau (requiert le module de connexion CA) (requiert le module de connexion CA) Des appareils externes et des Restrictions d'installation Aucune Aucune configurations conformer 6 la R6gle 21 peuvent 8tre exig6s pour la Californie Sp6cifications hors r6seau Aucune d6connexion/op6ration continue O A-25 A O A-50 A O A-75 A 5 s avant deconnexion 30 A-36 A 60 A-72 A 90 A-108 A 450 ms avant deconnexion 36 A-50 A 72 A-100 A 108 A-150 A 0 sonnen Specifications generales Mesures Refroidissement du systeme Convection naturelle Ports de communication Ethernet Front view Side view Protocoles de communication/ API disponible pour certains controle partenaires -27.08 in[689.9 mm] 13:85 in[351.8-mm] Caracteristique antisismique IEEE 693 Emission de bruit <25 dB Distorsion harmonique totale <5 Altitude de fonctionnement max. 2 000 m(6562 pi) ;aw;.�, FOI Systeme d'onduleur E photovoltalique per sonnen 6 kVA maximal recommande' E,e_ Surface de piece minimum pour 1J0 t*' SCORE-P20 12,15 m3 M1 u Informations Sur la conformite Certifications UL1741,UL1741SA,UL1973,UL9540,UN38.3 Code reseau IEEE 1547,1741 SA,Prepa 2013 Emissions FCC Section 15 Classe B(onduleur) CEI 61000-4-2:2008,CEI 61000-4-3:2010, Immunite CEI 61000-4-4:2012,CEI 61000-4-5:2014, CEI 61000-4-6:2013,CEI 61000-4-8:2009 E Protection contre les IEEE C62.41 Classe B r CIO transitoires iy O Garantie du systeme de 10 ans ou 10 000 apN lV Garantie' cycles-comprend I'onduleur,les modules de batterie,le cabinet et les composants Indite de('enceinte IP30 GSpecifications de la batterie Tension CC nominale 102 VCC Tension d'entr@e de la 96-112 VCC batterie c.c. Courant de charge 39,99 A par module maximal Decharge d'element° 5 kWh avec 100%de profondeur de de- charge Chimie des elements Lithium fer phosphate Protection contre les Protection par fusible surintensites Sous reserve de modification technique sans preavis.Les valeurs,sorties,autres donnees techniques,images et diagrammes contenus dans ce prospectus et dans les feuilles de donnees,publicites et autres documents promotionnels constituent des indications approximatives dans tous les cas ou ils n'ont pas ete identifies comme etant contraignants. 1 L'efficacite aller-retour maximum indiquee est calculde a I'aide de la formule d'efficacite de cycle d'aller-retour unique(Single Cycle Round Trip Efficiency-SCRTE)utilisee par I'administration SGIP en Californie,au moment de la publication de cette fiche de specifications. 2 En mode hors reseau,la batterie a une limite de charge maximum de 4,48 kW pour 1 systeme,8,3 kW pour 2 systemes empiles et 11,8 kW pour trois systemes empiles. 3 Veuillez respecter nos conditions de garantie applicables. 4 Les modules de batterie sM4 ont une capacite totale de 5,5 kWh et correspondent a 5 kWh de capacite utilisable par module. 5 Sur la base d'un systeme complet CA/CA RTE«round-trip efficiency»(efficacite aller-retour)a temperature ambiance de 25 C(77 F),debut de vie en mode hors reseau.Test execute par sonnen Inc.R&D.Donn@es de secours disponibles. Facteurs de conception Plage detaillee d'ef icacite aller-retours L'efficacite aller-retour du systeme sonnen complet varie en fonction des niveaux de puissance de charge/decharge,avec une plage d'efficacite attendue indiquee ci-dessous. La courbe«symetrique»dans la plage montre I'efficacite lorsque les taux de charge et decharge sont egaux. Les limites superieure et inferieure indique la zone d'operation du systeme,sur la base des variations de ces taux de charge et de decharge. Plage de fonctionnement de 1'efficacite Plage de fonctionnement de 1'efficacite aller-retour(RTE)de 10 kWh aller-retour(RTE)de 20 kWh 00 "'- i t -- 90 — — —------r----,---�------ --- -----1 I I —s so I so -�--- -- - -I---,-- —f— r F70 F—_____ —_._.__:._—�.—.�y_Symetrique Uj 70 _-____ .__..—_t._---._._:__ ___._..__I Sym6trique Inf€rieur Inferieur f I i Superieur I 1 j �-Superieur 160 60 __.__._�._I i --.-_�.____—. so 0 20 40 60 s0 100 120 0 20 40 60 s0 100 120 Niveau de puissance M Niveau de puissance(%) Diagramme a ligne unique pour la conception du systeme Ci-dessous,vous trouverez une vue d'ensemble du plan de conception pour un systeme sonnenCore+ unique avec un panneau des charges protegees pour I'alimentation de secours. Une consultation de conception de projet specifique pour les installations sur-mesure est disponible via I'Ingenierie Applications sonnen a designaa sonnen-batterie.com. r ulvsnrat r!�----�-- ❑ I r I II ----- --------- I Y. I ----- I— �wttaada I I I I I I w Uhum2k_ 'N I I �— -- ---------- -=J L—J I 1tci �x�a �n�a jswal I I i F 7wiwdk I I I I Remarques: L J 1.Compteur de service 2.Panneau de chargement principal de la maison 3.sonnenCore+ 4.Sous-panneau de charges protegees S.Onduleur PV en option Specifications et conception des sonnenCore+ empiles Les systemes sonnenCore+ sont con�us pour titre empiles,jusqu'a un maximum de trois unites par installation de site,en fonctions des reglementations electriques locales et Sur les recommandations d'un installateur certifie et qualifie. Diagramme a ligne unique pour la conception du systeme empile Remarques: wmmcar Msomm Debranchez avec un fusible 200A nominal avec des fusibles 200A(facultatif) +A"IMs Transformateur de courant 200A Module de connexions CA Panneau carr6 D 100A,CDM612L100SCP ou equivalent sonnenCore+BESS Panneau de charge electrique 200A Transformateur de courant 60A Solaire photovoltaique + f&m518 DALLL N ` n AM w�wcs�vcaumc I 1NaID I]G 7P 171M3P r----- -------, I i I I 1 mo AM L-- -- ---------1 j =om17P06D j IIa."Amc ].IOaW6IN CkII I I + I I Cut IaGOG�5i19 PAtffi �— I V u 1 mvmmey[w ..�*�. e+M1w r--------- ---1 I I I I 1+WIDIL47-1 -------- ) �mAncamu� n.wacrt a wawa F---- ————— I 4MhWGGrR=CAUE r---cll � l I Notes generales I I I —J Le dessin es[a titre de reference seulement et West I N o=mcLogs pas r6Fl@chissant des penetrations reelles de fils. I I Verifier la bonne mice a la terre selon National L———J Exigences du Code de 1'61ectricite(NEC). Tout 1'equipement electrique doit titre conforme a la Exigences relatives a I'autorisation de travail du CENE. Tous les travaux 6lectriques doivent titre conformes avec le CEE. Module connexions CA pour composants Specifications du module connexions CA critiques Dimensions L po/H po 16,3/36/6,1 1Ppo Compteur ° Poids 30 kg(67 Ib) Capacite nominale de 200 A o Contacteur circulation Tension 120/240 V Cote de courant de 10 KA avec disjoncteurs court-circuit Automatique Transfert La transition Transition ouverte("Pause avant Commutateur de faire") O O Piece jointe Type 16 I'interieur LEDs La certification UL1008 N.B.: Les entrees defongables pour les cables doivent titre r6alisees par o ° I'installateur. La consommation des TC est comprise. Disjoncteur sonnen Inc. ' 1578 Litton Dr,Stone Mountain,GA 30083 (310)853-2404 0 • 0080 00