HomeMy WebLinkAbout51728-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 51728 Date: 03/12/2025
Permission is hereby granted to:
William J Brennen
29 Harding St
Smithtown, NY 11787
To:
install generator as applied for.
Premises Located at:
1050 Trumans Path, East Marion, NY 11939
SCTM# 31.-12-5.1
Pursuant to application dated 02/05/2025 and approved by the Building Inspector,
To expire on 03/12/2027.
Contractors:
Required Inspections:
Fees:
GENERATOR $125.00
ELECTRIC -Residential $100.00
CO-RESIDENTIAL $100.00
Total S325.00
'g%W
Ins ecto � �
1"cling p r
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
� Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
r` Telephone (631) 765-1802 Fax (631)765-9502b s.-Z/www.southo1 tqw w
Date Received
APPLICATION FOR BUILDING PERMIT
"
For Office Use Only
PERMIT NO. 4-1 w. g Inspector:
Building Ins ;
FEB .)25
Applications and forms must be filled out in their entirety.Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owners Authorization form(Page 2)shall be completed.
Date:February 5, 2025
OWNER(S)OF PROPERTY:
Name:Willlam and Stacey Brennen SCTM#1000-31-12-5.1
Project Address: 1050 Trumans Path, East Marion, New York 11939
Phone#:631-974-5026 I Email:Williambrennen239gmail.com
Mailing Address:29 Harding Street, Smithtown, New York 11787
CONTACT PERSON:
Name:Willlam Brennen
Mailing Address:29 Harding Street, Smithtown, New York 11787
Phone#:631-974-5026 lE-mail-.Williambrennen23(�,Dgmail.com
DESIGN PROFESSIONAL INFORMATION:
Name:
Mailing Address:
Phone#: Email:
CONTRACTOR INFORMATION:
Name:Bruce Oster
Mailing Address:2300 Glenn Road, Southold, New York 11971
Phone#:631-767-8239 Email:BruceOster@gmail.com
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
E10therWhole House Generator $10,000
Will the lot be re-graded? ❑Yes �*No Will excess fill be removed from premises? ❑Yes ®No
1
,, PROPERTY INFORMATION
Existing use of property:Residential Intended use of property:Primary Residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? Dyes RNo IF YES, PROVIDE A COPY.
Check Box After Reading: The owner/contractor/design professionsl is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable taws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Vass A misdemeanor pursuant to Section 210AS of the New York State Penal taw.
Application Submitted By(print name):William Brennen ❑Authorized Agent WOWner
Signature of Applicant: Date: February 5, 2025
STATE OF NEW YORK)
COUNTY OF - �
W being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the 0
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith,.
Sworn before me this
day of 20 "Z/
No yP lc
WENDY k MAPON
Bthly Public,stqft of Nov"I"z
tl.OIST5070979
PROPERTY OWNER AUTHORIZATION ODOM in$A*cwt,
(Where the applicant is not the owner)
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
STORMWATER RETENTION CALCULATIONS: �! -
i '. m
` ADDITION ROOF: 780 SQ.FT.
I
780 SQ.FT.X 2 INCHfir RAiN=130 CUFT
[ USE B'DIA.POOL WITH 42.24 CUFTNF N 'cD
I 130 CUFT/42,24 CUFTNF=3.08 VF REQUIRED
RELOCATE WATER SERVICE LINE USE(1)-LEACHING POOL,8 FT CIA.,4 FT DEEP >
TO ALONG NORTH BOUNDARY. %
SUNROOM ROOF: 218 SQ.FT. wcu
218 SQ.FT.X 2 INCH/hr RAIN=36.34 CUFT o
/ S 4-� USE 4'DIA.POOL WITH 8.73 CUFTNF < E
36.34 CUFT!8.73 CUFTNF=4.17 VF REQUIRED w C i
USE(1)-LEACHING POOL,4 FT CIA.,5 FT DEEP = _ N
co
CESSPOOL
SHED TO BE ------- tr � .
DEMOLISHED II
vol
RO P,2-SI ORY 'a o
FRAME r` _
ADDITION ] wj
14
MINI SPLIT SYSTEMr j 1 r ZE
p`
1
MULTI ZONE
EXTERIOR UNIT
j .. o
iv
WELL
PROR
o
CONVERSION
FROM DECK:O ` I
I SJRt v , 4? 3 r s I
ON THE SAME :€ WELL PERSPECTIVE VIEW
i FOOTPRINT , ov, U
STINv {'
1 STORV� � PROP.H2O HEAVY DUTY c
38" MINIMUM 2 x 2 N
FRAM O F Qus�E B'DIA.4'DEEP STORMWATER n
FENCE POST
RETENTION LP WITH GRATE �+
PROP.WASTEWATER CONNECTION
/ WOVEN WIRE FENC
r
(Bx6 - 10110 WWF) c
w w CESSPOOL - c.
FILTER CLOT l c
SITE PLAN IS BASED ON SURVEY m
! ` ! BY JOSEPH A.INGEGNO LAND SURVEYOR
W000 J0 PHONE 631 727 2090 d
Jam/ �3 � 1380 ROANOKE AVENUE EMBED FILTER CLOTIa a
-- ; -RIVERHEAD,NEW YORK 11901
tia _ MIN. 6" INTO GROUND
LATEST DATED OCTOBER 19,2001
- u9
t - NOTE:
MAXIMUM DRAINAGE AREA N }
+� z
PROP.4 CIA,3'DEEP 112 ACRE / 100 LINEAR FEET
STORMWATER RETENTION LP L E i
TYPICAL SILT FENCE SECTION DETAIL g
r
Cu4p28'ps„ PROP,SILT FENCE
Stormwater Management Typical Silt Fence AR
Site Plan-Stormwater Management- n Details
D S R.25).-- NN m N ,
MAIN_R®A { ss \ STORMWATER RETENTION CALCULATIONS: I
\ ADDITION ROOF: 780 SQ.FT, m 0�
780 SQ.FT.X 2 1NCH/hr RAIN=130 CUFT i
USE V DIA,POOL WITH 42,24 CUFTNF [N L
130 CUFT/42.24 CUFTNF=3.08 VF REQUIRED
RELOCATE WATER SERVICE LINE USE(I)-LEACHING POOL,8 FT CIA.,4 FT DEEP )
TO ALONG NORTH BOUNDARY, s ( _+�.
SUNROOM ROOF: 218 SQ.FT, t ul
218 SQ,FT.X 2 INCHlhr RAIN=36,34 CUFT
/L USE 4'DIA.POOL WITH 8.73 CUFTNF` t' 8
C 36.34 CUFT/8.73 CUFTNF=4.17 VF REQUIRED {` CA€ ,
T USE(I)-LEACHING POOL,4 FT DIA.,5 FT DEEP _ ?;
€s� O 0__
�11�n 5SG t ^ to
G�zruvuL�� ` ;`
CSSiMOL r
SHED TO 8E
w .��y
Ica"� DEMOLISHED � � .
I oU XV
s �
t x-r' t
PROP.2-STORY tsu�as¢\ U i
FRAME MAM
ADDITIONrl
MINI SPLIT SYSTEM
MULTI ZONE O GRA :_
EXTERIOR UNIT t .' _ t tp£ - -f+ x t twu
{ _ '
PROP. - = ;
CONVERSION ? s
� FROM DECK TOSUNR
ONTHE SAME 'y �i Y _ WELL PE!3SPECTIVE VIEW
FOOTPRINT
r Eft z,
{ STORY PROP.H2O HEAVY DUTY
r ' RAMEO Hd c r 8'DIA.4'DEEP STORMWATER 36" MINIMUM 2 x 2 N
RETENTION LP WITH GRATE
FENCE POST
}" t PROP.WASTEWATER CONNECTION
WOVEN WIRE FEC
Ar
(8 x B - 10110 WWF) N
CESSPOOL
] f FILTER CLOT c,
� SITE PLAN IS BASED ON SURVEY
` BY JOSEPH A.INGEGNO LAND SURVEYOR
r== i <w000 { PHONE 631 727 2090 ®1
" srEOty 1380 ROANOKE AVENUE e
1-7v RIVERHEAD.NEW YORK 11901 EMBED FILTER CL-O7F} a
] ._ `O ^' , 6" INTO GROUND
g LATEST DATED OCTOBER 19,2001 4„
NOTE:
b0 aQ,-0, MAXIMUM DRAINAGE AREA
Oh PROP,4'DIA.T DEEP 112 ACRE 1 100 LINEAR FEET ]
STORMWATER RETENTION LP ++ g
o.0, TYPICAL SILT FENCE SECTION DETAIL v a g
�� '0 PROP.SILT FENCE
O
+ R 1s fists Storm}water Management Typical Silt Fence
, `N Site Plant-Stormwater Mar�aogMent- _ig£1 Details
ilss _ i N
N T.S.
BUILDING DEPARTMENT-Electrical Inspector
TOWN OF SOUTHOLD
rr Town Hall Annex - 54375 Main Road - PO Box 1179
z Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
iamesh southoldtownn ov seand southoldtownn , ov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: February 5, 2025
Company Name: BWO Electric Inc.
Electrician's Name: Bruce Oster
License No.: 64604 Elec. email:BruceOster@gmail.com
Elec. Phone No: 631-767-8239 El I request an email copy of Certificate of Compliance
Elec. Address.: 2300 Glenn Road, Southold, New York 11971
,FOR SITE INFORMATION (All Information Required)
Name: William Brennen
Address: 1050 Trumans Path, East Marion, New York 11939
Cross Street: Sound Avenue (Main Road)
Phone No.: 631-974-5026
Bldg.Permit#: email:williambrennen23@gmail.com
Tax Map District: 1000 Section:31 Block: 12 Lot:5.1
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Install New Generator 26 KW
Square Foota e:
Circle All That Apply:
Is job ready for inspection?: El YES �NO ❑Rough In F Final
Do you need a Temp Certificate?: YES Z NO Issued On
Temp Information: (All information required)
Service Size Ell Ph F]3 Ph Size: A #Meters Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect[-]Service Reconnect❑Underground❑Overhead
#Underground Laterals 1 02 0 H Frame R Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
d/9-
11 As PtaTEa_5P.
DA B.
IF_IE
F By
NOTIFY BUILDING DEPARTMENT AT
631-765-1802 BAM TO 4PM FOR THE
FOLLOWING INSPECTIONS:
1. FOUNDATION-p in,"IFnf PRED
FOR POUREL)i-,
2. ROUGH- r7,ArWj4k�if
3. INSULATION
GENERACO
4. FINAL-CONSTRUCTION MUST
BE COMPLETE FOR C.O.
AM CONSTRUCTION SHALL MEET THE
REQUIREMENTSOFTHE CODES OF NEW GUARDIAN® SERIES
26 kW YORK STATE. NOT RESPONSIBLE FOR Iti
DESIGN OR CONSTRUCTON ERRORS Residential Standby Generators
COMPLY Win ALL CODES OF Air-Cooled Gas Engine
NEW YORK STATE&TOWN CODES
NEW-- AS REQUIRED AND C NDI i TIONS OF
INCLUDES: LD TOM PLANNRJI,§93$ Standby Po -26 kW Power Rating Hz
• True Power"Electrical Technology OLD TO%TRUSTEES 14),G007291-0 lAIUMMUTTI-Bisque) 60
• Two-line multilingual digital LCD Evolution"controller 3 DEC,
(English/Spanish/French/Portuguese) OROLD HPO
• 200 amp service rated transfer switch available SCHO
• Electronic governor
• Standard W-Fio'connectivity OCCUPANCY
• System status&maintenance interval LED indicators USE IS UNLAWF(I I
• Sound attenuated enclosure
WITHOUT CERT11i
0 Flexible fuel line connector OF OCCUPANOY141
0 Natural gas or LO gas operation RdENERAC'
0 5 Year limited warranty ELECTRIC
INSPECTION REQ
• Base fasc a
• Listed and labeled for installation as close as 18 in(457 mm)to a
structure.*
*Must be located away from doors,windows,and fresh air intakes and in or C
accordance with local codes. QUIH-MST-
1 0%". LISTED
Note,CER.or CUL certification only applies to unbundled units and units ppackagecl
with limited circuit switches.Units packaged with the Small Switch are E
certified in the USA only.
FEATURES
0 INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
ei success in providing the most reliable generators possible.Gerlerac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod-
Force engine lineup offers added peace of mind and reliability for when it's needed els,It provides optimized FAST RESPONSE to changing load conditions and MAXI-
the most,The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge
rigors of extended run firnes in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at-1%.
0 TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave 0 SINGLE SOURCE SERVICE RESPONSE from Centered's extensive dealer network
form prodLOe less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small-
allows confident operation of sensitive electronic equipment and micro-chip based est electronic component.
appliances such as variable speed HVAC systems.
0 TEST CRITERIA: 0 GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with
• PROTOTYPE TESTED ✓ NEMA MG11.22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC
• SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system
compatibility.
,D MOBILE LINK""CONNECTIVITY:FREE with select Guardian Series Home standby
generators,Mobile Link Wi-Fi allows users to monitor generator status from any-
where in tha world using a smartphone,tablet,or PC.Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast,friendly,and proactive service.With
Mobile Link,users are taken care of before the next power outage.
=GENERAC � k o
0. �Zmo
PROMISE
GENERAC'
26 W Features and Benefits
Engine
• Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil-consumption and resulting in longer engine life.
• "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life,
• Electronic ignition/spark advance fh6k4fe'iures con'irit"ne'to assure smooth,quick slarf ng every throe.
• Full pressure lubrication system Pressurized lubrication to at]vital hearings means better performance,less maintenance,and longer engine
life.Now feabiring'up to a 2 yea,r1206 hour oil change interval,
• Low oil pressure shutdown system Shutdown prote'cfion-prevents�catastrophic engine damage due to low oil,
• EPA Certified for non-emergency applications Allows unit to be usedJor comarrd-rosponse applications.
• High temperature shutdown Prevents damage-due'to-overtreatInq.—
Generator
• Revolving field Allows for a smaller,,lightweight unit that operates 25%more efficiently than a revolving armature generator,
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability,
• Automatic voltage regulation Regulating output vq1tag I o�tll%prevents damaging voltage spikes.
For your safety..;V Q
• UL 2200 listed ";� � 9 11
Transfer Switch(if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 313 Can beinstalled inside or outside for maximum flexibility.
• Integrated load management technology Capability to manage additional loads for efficient power management.
• Remote mounting Mounts near an existing distribution panel for simple,low-cost installation,
Evolution"'Controls
• AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition,
• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences,
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations.
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home.
0 Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds.
• Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute.
0 Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
0 Small:battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries,
• Main line circuit breaker Protects generator from overload.
0 Electronic governor Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding
winds up to 150 mph(241 km/h).Hinged key locking root panel for security.Lift-out front for easy access
to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries.
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure.
I
GENERAC®
26 kW Switch Options
Service Rated Automatic Transfer Switch Features Model G007291-0(26 kw)
• Intelligently manages up to four air conditioner loads with no additional hardware. No,,et,010 2
Current rating(amps) 200
• Up to eight additional large(240 VAC)loads can be managed when used in conjunction V d `t tlnly A talk*,40,tO
with Smart Management Modules(SMMS).
Utility voltage monitor(fixed)'
• Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80%
Dropout 65%
• Main breakers are rated for 80%continuous load. 6s m1�Tlfft'rY" A"Orox 10sce
• 2-pole,250 VAC contactors. ETL or UL listed Standard r
• Service equipment rated,dual coil design. Circuit
Cnsl�uyp' FfL31t-
• Rated for both aluminum and copper conductors. Woq rn breaker protectedngy "�50 M M0
Y.0 raOM•#6
• Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly
Dimensions
200Amps 120/240,1e
Open Transition Service Rated
Height Width Depth
H2 W1 W2
in 26.8 1 301 10.5 1 13.5 6.9
67.95 76.43 26.67 34.18 _17.5
rWlire Ranges
re _ ..
Conductor Lug Neutral Lug Ground Lug ! 1
250 MGM #6 350 MCM #6 2i0 #14 ' eEr H 1
GENERAC®
26 kW Available Accessories
G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use If temperature regularly falls below 0°F(-18"C).(Not nec-
essary for use with AGM-style batteries).
G007102-0 Oil Warmer Oil warmer slips directly over the oil flfter.Recommended for use if temperature regularly falls below 0°F(-18"C).
G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where'
heavy icing occurs.
' G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be
Contact Kit needed.Not compatible with 50 amp pre-wired switches.
G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured
appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
G005703-0-Bisque Touch-Up Paint Kit if the generator enclosure is scratched or damaged,it is importantto touch up the paintto protect from future corrosion.
The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automatic standby generator(oil not included).
G007005-0 Wi-Fi LP Tank Fuel Level The WkFi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the
Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta-
tus alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec-
G007006-0 itrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce
(100 amp) Ahe overall size and cost of the system.
0007169-0-4G LTE Mobile Linker Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using
G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us
Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,
users are taken care of before the next power outage.
G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured
appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit
contains four plugs,sufficient for use on a single air-cooled home standby generator.
Dimensions & UPGs
Model _......-UPC
83'l.e 28 M
[4—
GG0000772291-0 6699664477110088773314
nIzTe..ze mlnm]
Oln�
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are approximate.See installation manual far exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
GENE RAC® Generac Power Systems,Inc.•S45 W29290 HWY.59,Waukesha,WI 53189•generac.com
02022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0002026894 Rev.0 04/26/2022
GENERAL'
26 kW Specifications
Generator
Model G007290-0
G007291-0
(26 kW)
Rated maximum continuous power capacity(LP) 26,00041
Hated maximum continuous power capacity(1 22,500 Watts"
Rated voltage 240
Rated maximum continuous load current-240 volts(LP/NG) 108.3/93.8
r ' Total Harmonic Distortion Less than 5%
Main line circuit breaker 110 amp
Phase 1
Number of rotor poles 2
Rated AC frequency 60 Hz
Power factor 1.0
Battery requirement(not included) 12 Volts Group 26R,540 CCA!minimum or Group.35AGM 650 CCA minimum,
Unit weight lb/kg) 518/235
Dimensions(L x W x H)in/,cm 48 x 25 x 29/121:9 x 63.5 x 73.7
Sound output In dB(A)at23 ft(7 m)with generator operating at normal load"' 67
Sound output in d8(A)at 23it(7 m)with generator In 0uiot-Test'"low-speed exercise mode'* 57
Exercise duration 5 min
Engine
Engine type GENERAC G-Force 1000 Series
Number of cylinders 2
Displacement 999 cc
Cylinder block Aluminum w/castnon sleeve
Valve arrangement Overhead valve
Ignition system Solid-state w/magneto
Governor systern Electronic
Compression ratio 9.5:1
Starter 12 VDC
Oil capacity including filter ;. Approx 1.9 of/1..8 L
Operating rpm 3,600
Fuel consumption
Natural gas ftalh� 18fl(5,32)
'Full,Load; 333(9 a3)
Liquid propane el wal/ho(or] 75(06}:(7,78)
172 Load Full Load; 132(&"J13,73)
Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5--7 in water column(0.87 1.74 kPa)for NO,10 12 in water column(2.49-2.99 kPa)for I-P gas.
For BTU content,multiply x 2500(LP)or ftemr x 1000(NG).For Megaioule content,multiply mVhr x 93,15(LP)or m'/hr x 3726(1
Controls
Two-line plain text multilingual_CD Simple user interface for ease of operahon.
Mode buttons:AUTO Automatic start on utility fallum.Weekly Bi-weekly,or Monthly selectable exerciser,
MANUAL Start with starter control,not stays on.If utility fails,transfer to load takes place.
OFF Stops unit,Power is removed.Control and charger still-operate.
Ready to Run/Maintenance messages Standard
Engine run hours indication Standard
Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)-
Utility Voltage Loss7Relurn to Utility adjustable,(brownout setting) From 140-171 V/190-216 V
Future Set Capable Exerciser/Exercise Set Error warning Standard
Run/Alarm/Maintenance logs, 50 events each
Engine start sequence Cycl to cranking:16 sec on,7 rest(90 sec maximum duration).
Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger Standard
Charger FaulVMissing AC warning Standard.
Low Battery/Battery Problem Protection and Battery Condition Indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Under-Frequency/Overload/Stepper Overturned Protection Standard
Safety Fused/Fuse Problem Protection Standard
Automatic Law Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed(@ 72,Hz)/rpm Sense Loss Shutdown Standard'
High Engine'temperature Shutdown Standard
Internal Faulblocorrect Wiring protection 'Standard
Common external fault capability Standard
Field upgradable firmware Standard
Rating definitions--Optional Standby Applicable for supplying backup power forms duration of the utility power ounage,with correca maintenance performed.
*No overload capability is available for this rating.(All ratings in accordance with OS55'14,1SO3046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as
fuel BTU/Mogajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000`1(304.8 m)above sea level and approximately 1%
for each 10'F(6'C)above 60'f(16°C).""Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.
US,EPA codified for non-emergency applications.
GENERAC®
26 kW Features and Benefits
Installation System
• 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity(WI-Fi equipped models only)
• Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for
complete peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.