Loading...
HomeMy WebLinkAbout51710-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51710 Date: 03/05/2025 Permission is hereby granted to: Joyce A Orrigo 130 Stanley Dr Centereach, NY 11720 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 15925 Route 25, East Marion, NY 11939 SCTM#21-1-11.3 Pursuant to application dated 01/24/2025 and approved by the Building Inspector. To expire on 03/05/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total $32S.00 gilding Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-95021poid1�� Date Received APPLICATIONi r _ For Office Use Only u �( [PERMIT N0, Building Inspector:_,_ � ' JAN 2 4 Applications and forms must be filled out in their entirety. Incomplete w applications will not be accepted. Where the Applicant Is not the owner,an Owner's Authorization form(Page 2) shall be completed. Date: I 10 I dpa� OWNER(S)OF PROPERTY: Name: SCTM# 1000-� C�r-�c C;.33.(OC:)�- off. oo� o1N vo3 Project Addre /S"C�a S r n o C ( d�-t oz✓v�r'o n Ivy I I �' 9 Phone#: Email: Mailing Address:. CONTACT PERSON: Name: Mailing Address: « 3 Po nc� scar RoC., �Xscv,(a 1 l_,4q`j' Phone#:(>3� -� a-q Email: br lonZ DESIGN PROFESSIONAL INFORMATION: �� �� .. Name: mc.s J (- Mailing Address: a Phone#:(�,31_�� Email: csA'b.7k-h v�o j-)jarneSS'}o�}c%.rC.�, CONTRACTOR INFORMATION: - ------- Name: Lw`(rn-vyiw) Sb`o, L`Rc. Mailing Address: Icp,3 P6 ecl otYl o• Phone# Email:b ra 0� m'��eU i� 1rc�s n�c1c c o� DESCRIPTION OF PROPOSED CONSTRUCTION El New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition %Dther y0 Estimated Cost of Project: L " $ 00 Will the lot be re-graded? ❑Yes ado Will excess fill be removed from premises? ❑Yes �D o 1 PROPERTY INFORMATION Existing use of property: S%rj�-2_ cci`>\1����— Intended use of property:Sav3Lr' Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ;huF ck Box After Reading. The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.4S of the New York state Penal Law. Application Submitted By(print name): /��� �j4uthorized Agent ❑Owner Signature of Applicant: Date: 1/ 0/2. STATE OF NEW YORK) SS: COUNTYOF <SO4tlL ) TM 4,'°'(`h being duty sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor, Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this t� o mJ day of 20 jNotar sl 4 a 3 PROPERTY OWNER IM " ) (Where the applicant is not the owner) � arliil ° I, residing at Q fC� do hereby authorize r:F to apply on my behj to the T wn of Southold Building Department for approval as described herein. wn r" g n re Date Print 40wner' am 2 /?--011%, NYSIF Now York State umnsu rana:a Fund PO Box 66699,Albany, NY 12206 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE ^^^^^^ 834647988 INTEGRATED COVERAGE GROUP INC 20 HEMPSTEAD TURNPIKE FARMINGDALE NY 11735 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER LEVIATHAN SOLAR, INC. TOWN OF SOUTHOLD 1993 POND ROAD 54375 NY-25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12566 592-8 777242 03/18/2024 TO 3/18/2025 3/18/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2566 592-8, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/AAfM.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND 4 */ DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 300980355 U-26.3 0 [:!7129/2024 (MWDD/YYYY) . 1 L> CERTIFICATE OF LIABILITY INSURANCE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Bill Visgauss PHONE Argyle Lake Insurance Agency A/C No Ext (631)581-2400 ( ); 631-661-8469 181 W Main St Ste.102 ADDRES& bill(e ViS94USs.Com INSURER(S)AFFORDING COVERAGE NAIC# Babylon NY 11702 INSURER A: Atlantic Casualty Ins Comp 42846 INSURED INSURER B: Leviathan Solar Inc INSURER C 1993 POND RD INSURER D: INSURER E: RONKONKOMA NY 11779 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE_ _ INSD WVD POLICY NUMBER (MM/DD/YYYY) MM/DD/YYYY� LIMITS Jif COMMERCIAL GENERAL LIABILITY - _ EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE OCCUR PREMISES(Ea ocfnutiPdtaticCa) $ 100,000 MED EXP(Any one person) $ 5,000 A _ X 1357002696 7/28/2024 7/28/2025 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $ 2,000,000- POLICY JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ ............. AUTOMO BILE LIABILITY �Eaaerweno www ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS _. HIRED NON-OWNED PT --- AUTOS ONLY AUTOS ONLY (Per acddeinll $ UMBRELLA Ell_AB LCCIREACH OCCURRENCE $ EXCESS LIAB S-MADE AGGREGATE $ www wwwww DED RETENTION$ $ ORKERS COMPENSATION w_w w... ...-._....____..._.�. . .. 'OT1-i_ AND EMPLOYERS'LIABILITY Y/N STATUTE w.. .rEA ANY PROPRIETOR/PARTNER/EXECUTIVE N/A E L EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? Mandatory in NH) E L DISEASE-EA EMPLOYEE $ ff yes,describe under DESCRIPTION OF OPERATIONS below E,L,DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Solar Panels Installation,Sales,Service&Repairs,Class Code 99080 Solar energy Contractors Blanket Additional Insured Coverage Applies CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 54375 NY-25 AUTHORIZED REPRESENTATIVE Southold NY 11971 Wm. K. v4gatkss Q 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD ed APZP "QED AS AS NOTED D A B.P.# VIV F E El- BY: NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS ELECM-11CAL INS i REQUIRED COMPLY WITH ALL CODES OF NE'W YORK STATE &TOWN CODES AS REQUIRED AND CONDITIONS OF SOnOLD W N ZBA WHO L om Pd ANNING BOARD SC TOWN TRUSTEES NY& c ___^----------- S OLD HPC D (')' CCUPANCY' 0R USE IS UNLAWFUL, wr"rHOUT CERTIFICA"T" ' OF OCCUPANCY J AMES J. S TOUT A R C H I T E C T & ASSOC . 2 G R E G L A N E E AST NORTHP0R TN. Y. 631 - 8 58 9388 Letter of Certification January 10, 2025 Re: Orrigo Residence 15925 Main Road East Marion, NY 11939 To Whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above listed address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS (RCNYS), 2020 Energy conservation construction code of NYS (ECCCNYS), and the ASCE 7-16. The existing 2" x 10" @ 16" o.c. roof rafters have been analyzed and will provide adequate support. Thank you for your understanding in this matter. Sincerely, James J. Stout � ; D qq cc Lon -72.321574� PHOTOVOLTAIC ROOF MOUNT SYSTEM _ 10 REC460AA Pure-RX MODULES ROOF-MOUNTED - 4.600 kWDC 13.800 kWAC 15925 Main Road, East Marion, NY 11939 APPLICABLE CODES, LAWS AND PROJECT LOCATION SHEET INDEX REGULATIONS & VICINITY MAP LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 117T - +1 631-553-2732 Cl-COVER SHEET 2020 NEC info@@ Ieviathansoiar.com R1-SOLAR LAYOUT AND ROOF INFO. 2020 BUILDING CODE OF NYS HI-65859 2020 RESIDENTIAL CODE OF NYS R2-PLOT SURVEY PAGE. 2020 EXISTING BUILDING CODE OF NYS 2020 FIRE TITLE: R3-ROOF PLAN WITH MODULES. COVER SHEET CODE OF NYS PARCEL ID: R4-RAFTER VIEW,MOUNTING DETAILS&BOM. 2020 PLUMBING CODE OF NYS 1000-023.00-01.00-01 1.003 2020 MECHANICAL CODE OF NYS E1-ELECTRICAL 3-LINE DIAGRAM. CUSTOMER NAME: Joyc Orrigo P1-PLACARD BREAKDOWN. GENERAL NOTES. CUSTOMER ADRDRRESS: S1-EQUIPMENT SPEC SHEETS. 1.SOLAR PANELS WILL BE 10(REC460AA Pure-RX)WITH AN 15925 Matti Road OUTPUT OF 4.600 kWDC AND 10(IQ8X-80-M-US) S2-EQUIPMENT SPEC SHEETS. MICROINVERTERS. East Marlon, NY 11939 2.INSTALLATION IN ACCORDANCE WITH MANUFACTURER S3-EQUIPMENT SPEC SHEETS. RECOMMENDATIONS. AHJ: 3.ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND Town Of Southold S4-EQUIPMENT SPEC SHEETS. CERTIFY COMPLIANCE { UTILITY: pA 4.PROJECT TO BE INSTALLED WITH CODE COMPLIANT PSEGLI SYSTEM- DATE: 12/20/2024 STAMP & COMMENTS. RACKING INSTRUCTIONS FOR SNAPNRACK SOLAR MOUNT 5.FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. ., 6.THE SOLAR INSTALLATION CONTRACTOR,COMPLIES WITH DRAWN BY: ALL LICENSING&ALL RELATED REQUIREMENTS OF THE FELIX GONZALEZ GOVERNING MUNICIPALITIES AND THE LOCAL ELECTRIC evia UTILITY AHJ'S. Felix 1 809t703-7147com 7.THIS PROJECT WILL COMPLY WITH THE CURRENT NEC REQUIREMENTS INCLUDING ARTICLE 690 SOLAR PHOTOVOLTAIC PV SYSTEMS. PLANS REVISIONS 8.THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER OF ROOF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. 1 4-4-- 9.INSTALLATION WILL BE FLUSH-MOUNTED,PARALLEL TO AND NO MORE THAN 6.5"ABOVE ROOF 2 10.MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE AND AT i ONE GABLE EAVE. 15925 Main Rd East 11.THIS DESIGN COMPLIES WITH 140 MPH WIND Marion NY 11439 REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S AND Dam s d. cpd ASCE 7-16. 12.WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH ate ` ACCESS AND VENTILATION REQUIREMENTS OF THE UNIFORM 14, Z s CODE,LEVIATHAN SOLAR PROPOSES THAT ALTERNATIVE VENTILATION METHODS WILLBE EMPLOYED.REVIEW AND S f. APPROVAL SHALL BE AT THE DISCRETION OF THE MUNICIPALITY IN WHICH THIS DOCUMENT HAS BEEN FILED. g f 13.THE DESIGN PLANS COMPLY WITH THE 2020 NEW YORK � '� STATE UNIFORM FIRE PREVENTION AND RESIDENTIAL BUILDING CODE - --- -- - - LEGEND � Lon:-72.32157 1�! t8"RIDGE SO M6'ROOF ACCESS 36'GROUND LAR MODULE: t , UTil11Y METER L=J / - SEl13ACK SETBACK ACCESS RECGSOpA PueRX �w METER k:VP%OC;80d0%52 AC AC MSPpgHE��E ENVOY gg_t-xqg- �J ACC M:iPXOC;%840t0802 dSCONNEGT 36"ROOF ACCESS u - 36"GROUND ACCESS , E ,- LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 1177: +1 631-553-2732 VENT info@leviathansolar.com PIPE HI-65859 ,- - TITLE: SOLAR LAYOUT& ROOF INFO. (N)ENVOY m (N)AC DISCONNECT n CUSTOMER NAME: UTILITY METER Joyce Orrigo MAIN SERVICE PANEL z f= SKYLIGHT CUSTOMER ADRRESS: CHIMNEY z L= 15925 Main Road i= East Marion,NY 11939 I ; - AHJ: 36"GROUND ACCESS F Town Of Southold _x F UTILITY: PSEGLI DATE: 12/2012024 36"ROOF DECK ACCESS DRAWN BY: FELIX GONZALEZ Felix@leviathansolar.com +1 809-703-7147 PLANS REVISIONS ti 2 --l--/— >2 DRIVEWAY Joyce Orrigo 61 '.�eu AR, 15925 Main Road s ` , 10 PANELS �� 15925 MAIN ROAD 4 ' qF LtGtNU L.ai. •r I. wwv SOLAR MODULE: UTILRYMETER Lon:-72 321574 f i6"RIDGE X 36"ROOF ACCESS 36"GROUND AC c+ MARi SERVICE ENVOY SETBACK 4 SETBACK �. ACCESS RECA60AR Puec-RX I m I METER#.QC;86 30%62 �C DISCONNECT.. --. �J _-- - PANEL --- E -. H6.1�x99� L--1 AGC N:�PXOC;9666010802 LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 1177! '1 631-553-2732 info@leviathansolar.com 161-1 V H I-65859 TITLE: PLOT SURVEY PAGE CUSTOMER NAME: Joyce Orrigo CUSTOMER ADRRESS: 41 15925 Main Road East Marion,NY 11939 AHJ: Town Of Southold UTILITY: PSEGLI DATE: 12/20/2024 DRAWN BY: FELIX GONZALEZ Feiix@leviathansolar.com +1 809-703-7147 PLANS REVISIONS 1 —l--t- 2 --t--/-- N �Q rfi VF Lai'� S LEGEND Lon:-72.32157 K3 I SOLAR MODULE: STRUCTURAL r=— RAII REC460AA PURE-RX ATTACHMENT 68.1"x48" LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 1177! 11_611 I i I I i I +1631-553-2732 !, [; info@leviathansolar.com HI-65859 21-1011 TITLE: i i I SOLAR PLAN WITH MODULES 2'-10" 1 13'-5" CUSTOMER NAME: O I Joyce Orrigo 2'-10" I CUSTOMER AD RRESS: j 15925 Main Road East Marion,NY 11939 AHJ: 1'-5" I Town Of Southold UTILITY: PSEGLI 4' 2024 DRAWN _ 11" '-4" 1-t�.11 '_1�" 1+_3ee DATE: 12(20( '-4' FELIX GONZALEZ 1 31—�H Felix@leviathansolar.com 5" 22'-2" +1 8U9-703-7147 SOLAR LAYOUT: THIS ROOF WILL HAVE 10 REC460AA PURE-RX 460 WATT PANELS WITH AN PLANS REVISIONS OUTPUT OF 4.600 KW AND 10 IQ8X-80-M-US MICRO INVERTERS. 1 -(-(-- 2 --(-(-- Attachment MAX-Attachment MAX-overhang RAILS QTY, ATTACHMENT QTY, Roof tilt Roof Azimuth Type Framing Type Framing Size OtC spacing Spacing 4'• 17" ROOF 1: 80 FT t 6 PCS OF 172"RAIL ROOF 1:24 PCS Roof 1 24° 236° SNAPNRACK WOOD RAFTER 2"Xt0" t6" 6 _iti� C4 t i� d. y g 02 63 gel' rF OL N£'j gal. 7 Lon:-72.321574 2"x1 Q"RAFTERS @ 16"O.C.(TYP-) —REC460AA Pure-RX SOLAR PANELS LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 1177! +1 631-553-2732 24' info@leviathansolar.com HI-65859 TITLE: RAFTER VIEW, MOUNTING DETAILS& BOM SPAN: CUSTOMER NAME: Joyce Orrigo ROOF CROSS SECTION RAFTER VIEW CU 15925 M ADRRESS: 15925 Main Road N.T.S East Marion,NY 11939 AHJ: Town Of Southold UTILITY: PSEGLI DATE: 12/20/2024 DRAWN BY: BOM MID CLAMP SNAP N RACK M-40 RAIL FELIX GONZALEZ Felts@leviathansolar.com - Pr MODULE j +1809-703-7147 80 FT PV MODULE J/ Q PCs PLANS REVISIONS SNAP N RACK 6 PCS SNAP N RACK £ !j UR-40 RAIL UR-40 SPLICE h COMPOSITION SHINGLES I` f—SFEE-IFALFOOT 2 --l--l-- 26 PCS 14 PCS 5/16"X 4 LG.S.S.LAG BOLT SNAP N RACK u € WITH 5Ii6'WASHER P. CENTER i SNAP N RACK TYP.PRE-DRILL REQUIRED. SPEEDSEAL FOOT MID CLUMP s j y 2 E)RAFTER e g, a _� a I 0.75 MIN F 9�=6`z' O t I Y 12 PCS \ 14 PCS SNAP N RACK ROOF ATTACHMENT DETAILS €`xj SNAP N RACK HARDWARE: SPEED SEAL FOOT END CAP GROUND LUG SPECIFICATIONS SERVICE INFO._.. -. "". '• •"""""" SOLAR MODULE SPECIFICATIONS AMBIENT TEMPERTURE SPECIFICATIONS INVERTER LOn`-7Z.3Z1574 - TEMPERATURE --- NOMVOLTAGTPUT NOMINAL OUTPUT -- - -- MANUFACTURER/MODEL# QUANTITY VOLTAGE CURRENT UTILITY PROVIDER:PSEGLI MODEL# VMP IMP VOC ISC COEFFICIENT #OF MODULES CONDUCTOR CONDUCTOR - MAIN SERVICE VOLTAGE:240V OF Voc RECORD AMBIENTTEMPTEMPERATURE TEMPERATURE IQ8X-8o-M-US 10 240 VAC 1.58A MAIN SERVICE PANEL:200A REC460AA PURE-RX ---- - --- ---- LOW TEMP (HIGH TEMP 2%). RATE(ON RATE(OFF -- --- - -- - -- - - MSP LOCATION:BASEMENT (A6CV) 418 9A5 487 10.07 027%d`C 10 ROOF) ROOF) - - MODULE DIMENSION- 68 1"L x 48 W x 1.26"D ----. 15, 31' 9o, ---- -75" -- -- - - - SYSTEM SIZE:-lox 46OW=4.600 kWDC NOTE:1"PVC CONDUIT - -- '.. mX 38OW=3a00 kWAC RUN(7f8"ABOVE ROOF) LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 1177! +1 631-553-2732 InfoQlevlathansolar.Com HI-65859 UTILITY METER#: 98309652 '.,. 10 MICRO-INVERTERS IN BRANCH CIRCUIT ACCOUNT# 96e4010602 TITLE: (10)IQsx-Bo-M-us ELECTRICAL 3-LINE —IMICRO4NVERTERS(240V) I (LOCATED UNDER EACH PANEL) DIAGRAM ` AC DISCONNECT CUSTOMER NAME: 60A; i Joyce Orrigo LINE SIDE TAP -- 5A CUSTOMER ADRRESS: t (N)(ROOF)JUNCTION BOX —_. --. .....—.._... (E)MAIN BREAKER 15925 Main Road _� _ — -- 2P.240V East Marion,NY 11939 AHJ: � ! Town Of Southold UTILITY: PSEGLI - G DATE: 12120t2024 N I ( DRAWN BY: FELIX GONZALEZ EXISTING GROUNDING A" I (f'--, SYSTEM FelixOaleviathansolar.com --}- - +1 809-703-7147 PLANS REVISIONS 1 --t--l-- 2 --t-t-- CONDUCTOR SCHEDULE AND CALCULATIONS Wire Temp. Wire Temp. Conduit Derated Inverter NOC(A) NEC Design Ground Ground Wire nFu=� Wire Tag Conduit Wire Type Rating Am aci A Derate Fill Derate Am aci A Qty Correction Current(A) Size Type - f Gauge g P tY{ } P tY{ } -_ _- � ;3 r -- --' 0.94 ---1.0 -- 28 BO -- 10 1.58 1.25 19 75000A 06 AWG BARE CU A OPEN AIR 12 AWG QCable 75`C 30 _ -- . j . B ill PVC 10 AWG THWN-2 75"C 40 0.94 0.80 30.72 10 158 1.25 19.75000A 10 AWG THWN-2 .�.•-iy. 2163,y0� C ill PVC 10 AWG THWN 75"C 35 0.94 1.0 32.90 N/A 1.58. 1.25 N/A 10 AWG. THWN OF r { D '.. ill PVC 6AWG THWN 75`C 65 0.94 1.0 61.1 10 1.58 1.25 19.75000A 06AWG... THWN `' L Lon. 72ao -72.321574; SOLAR �� 157 r POWER SOURCE EQUIPPED WITH OUTPUT CONNECTION DO NOT RELOCATE THIS _ OVERCURRENT DEVICE RAPID SHUTDOWN LABEL LOCATION: LABEL LOCATION: SUB PANEL(AC DISCONNECT)&UTILITY METER SUB PANEL(AC DISCONNECT) LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 11771 _ SOLARLL�i I +1631-553-2732 PV SYSTEM DISCONNECT nfo@Ieviathansolar com i , • i HI-65859 ELECTRIC SHOCK HAZARD TITLE: TERMINALS ON THE LINE AND LOAD SIDES RATED AC OUTPUT CURRENT 15.80 A I PLACARD BREAKDOWN MAY BE ENERGIZED NOMINAL OPERATING AC VOLTAGE 240�V TURN RAPID SHUTDOWN SWITCH TO CUSTOMER NAME: IN THE OPEN POSITION Joyce Orrigo THE "OFF" POSITION TO SHUT DOWN LABEL LOCATION: LABEL LOCATION: CUSTOMER ADRRESS: SUS PANEL(AC DISCONNECT)&MAIN SERVICE PANEL MAIN SERVICE PANEL&SUB PANEL(AC DISCONNECT) PV SYSTEM AND REDUCE 15925 Main Road SHOCK HAZARD IN THE ARRAY East Marion, NY 11939 AHJ: Town Of Southold LABEL LOCATION: DUAL POWER SUPPLY SUB PANEL(AC DISCONNECT) _ _- PSIEGLI 10 SOURCES: UTILITY GRID AND DATE: 12l20J2024 I PV SOLAR ELECTRIC SYSTEM $ DRAWN BY: FELIX GONZALEZ LABEL LOCATION: LABEL LOCATION: Felix@leviathansolar.com MAIN SERVICE PANEL&UTILITY METER MAIN SERVICE PANEL In3c_nvor +1 809-703-7147 any ac oiscaxtacT Maw E�EPn ® PLANS REVISIONS 2 J--J-- TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL PHOTOVOLTAIC POWER SQR WCE , £ j- 1 LABEL LOCATION: LABEL LOCATION: vawA. f Force oms, JUNCTION BOXES&MAIN SERVICE PANEL CONDUIT&JUNCTION BOXES lsszsr 10 PANEELSLS as >`t $ lF�'71 Y r PF E`Y 15925 MAIN ROAD Lan: 3f Lon:-72.321574C+�) iEE l • 1 • • • • SOLAR'S MOST TRUSTEDREC vy . . 63h Ift FECh t }jA�1 RE[ f ALPHA eY 32 Cell Typ f I1 ttA e g �\ mm ciarglas>w'ha t fl t t mac,—di,, th EN12150 I. •` .'1� \ \\\�\� \�•�' Becksheet Hghy 't tpiy t, k) �\\\\\� Frame A PURE—R SERI \ \\�\\�� o rt4cb it r +> 1 \�� � Junction Dox p by - v� p68 d n-Ec6z LEVIATHAN SOLAR INC \\\\\ \ Uhl. tws t b UC4.V rc.bl,STA(.: ) ma< dan<a"ithiEC62852 P68 ly Mn t d 1993 Pond Rd,Ronkonkoma,NY 1177! �� SHEETTA Vv A 4. i 61 with .718 +1 t331-5ansola 2 � Uhl. da 3 (208ENS0 1a info cCleviathansolar cam �A AAA 1728x120'x30 208m� i Dimans�ens ) VA weight p H I-65859 \ \ 0ngin viade nS ngaPore ELECTRICAL DATA, PFCDtss,COW Rc'Cxx Pt=--:Rx CERTiF1i:A7i0N5 j TITLE_ Power0uiput P, (W,) 450 455 460 465 470 IECa"21's 20211EC61730.0761A 67730 t EQUIPMENT SPEC 150119252 Igmt bl'ty(N;3501-1Class E) ; watt Hass Sorting-(wJ 8f.5w 0(•5w Of.Sw 0,l•SVt 0jr6N' IEC 62716 Ammania ftesis;ae<e SHEETS Nominal Power Voltage-V,(V) 543 546 549 552 554 IEC61701 Saltht:s"(SM6) `- NominatPower Current-1,p„(A) 829 834 838 843 849 IEC61215:2G76 F-Tyna(35 tutu) UL 61730 F�raTypez a CUSTOMER NAME: F open0—itVoltage-V,M 65-1 652 653 655 656 ISO,4001;1509001:IEC45001,1EEC62941 Joyce Orrigo ut Shartlo—itCurreM lx(AJ 881 a84 888 891 89S PowerD—ily(W/m') 216 219 221 224 226 taketwa V CUSTOMER ADRRESS: Panel Effiaency t%) 216 219 2z1 223 226 `-C E FE11 ,.-_ 15925 Main Road East Marion. NY 11939 Power Output-pmax(W') 343 346 350 354 358 00 Nominal PoserVcltage-V,(V) 112 514 517 520 522 AHJ: Z Nominal Power Correll-I_(A) 670 6.73 677, 6.81 686 wA(tRANTY open Cvcwtvoltage-vx(v) 613 61.5 616 617 616 Standwd REC PrOTrust Town Of Southold Inrtal(ed by.. UTILITY: Short Circuit Current I (A) 711 .1' 7 72 7,23 RECCertified Na Yes Yes t P.f.W. PSEGLI <25 kW 25-500 kw W w.y System A11 DATE 12t2412Q24 Prnd rct arranry 20 25 25 MAXIMUM RATINGS'. #MPV2ATURE RATINGS- (Y-) Pvwerwar rq 2s 25 254°C t 2=C DRAWN BY: Oper.c—'Temperature -40"C 85`C Noml al Modoleopemting tyrs) syst mvmtage loco Temperature 4 Labetwarranty a zs 10 FELIX GONZALEZ Maximum Test F Se Load(ffontJ -0D'a^.O Pa(3i5 kg;mtj Tem Wrernefficientaf Pam, -0-4%°C (Yrsl `�\�\ Maximum st Lvad(rear) 00Pa 14G7 kg(m�i pars - Power.Yearl 98% 98% 98% Te a \4 Temperature.effidW of V� 0.4%'-C M. nes use Rating 5A Tempe to ffi EI Il4Y.(eC Anmiat Degradation 0 Felix leviathansolar Com M 25°m` 425% 025% Q +1 603743-7147 Max Reverse C-1 75A �z,e re-aaz aem .... ..gym.p.a xn PowernYear 25 92% 92% 92% m I—A,o d°a N h y� DEL}VERY INFORMATEDNa,R�s ece.t 5 „„;ro.b..re�rn•..,< vy v Pane is P.,Patlet 33 a PLANS REVISIONS �\ \\\`� <:.... N-is per 40 ft 6PPo,gh S 4 8 is LD4VL)CHTBEktAVIOLIR s �� 7 Panels per136 m truck E60(2GPa.lets) fP�naw lrrad�a ep�rfor an<e orm,.,:Je a.STC 2 1_1 m F ?!iu' ...0 �#§ � L -pg F a 2 T 5 63 A3 R C C xuma4:�r�+aagi,incy^e:a_ he�eG�a.ars 5 ga,ce RF�a zc hasrege atwbsn a g'P �; .:.may+ E«are aid r.,o ar r:� LBIT: 4 Lon:-72.32157151 ENPHASE IQ8X Microinverter Commonly used module pairings' w 320-540 Module compatibility To meet compatiWlty.PV modules must be rtr.:nM YC-C tags ad tl.T �dws`1 Es+eciw y, Module compallb lrty can bechecked att -st ./�.ai�-t MPPT vottageranga Y <S_60 Operetingrang. V 25-79.5 Minimum and Madeurn wkage V 30-7as LEVIATHAN SOLAR INC M.-input DC vdtage Y 79.5 1993 Pond Rd,Ronkonkoma,NY 1177! MaX.contlnuousopemting DCaurrem A 10 +1 631-553-2732 Max.input OC short-cucui[wrrent 16 info@leviathansolar-corn Max.maaul.Ik A 13 HI-65859 CYervoltag.can,Do port 11 DC port beckfeed current mA 0 PV snnn nfi Un array; ;;no addirional DC aide protection required:AD aide protection oetim,max 20 A par branch circuit TITLE: y`° g°`ar`°° EQUIPMENT SPEC Peak output pnuer VA 384 MeSHEETS Max.continuous output power YA 3.0 360 iQ8X Microinverter Nominal grid vottege(L1) V 240.apIt-phase(.-I-116W 208.single-Phaae(1120' CUSTOMER NAME: Minimum and Maximum grid.[.go' v 211-264 183-229 Joyce Orrigo Our newest IOB Series Micminvertem are the industry's first micmgrid-formlrlg',software- Easy to install M.—minuousoutputcunum A 1,58 1.73 CUSTOMER ADRRESS: defined microinverters with split-phase power conversion capability,to convert DC power to Nominal frequency xz so AC power efficievaty.I=Mmmimerter is the latest addition to this family,designed to support •Lightweight and compact with plug- 15925 Main Road PV modules with higher input DC voltage and cell counts,such as 96 cells,80 half-cut cells, and-play connectors Ertandedfrequencyy range a: 47-°8 East Marion, NY 11939 and 68 half-cut calls.The brain of the Semiconductor-based microinverter is our Proprietary -Power line communication(PLC) AC short circuit fault current over three cycles urns 2.70 application-specific integrated c'vovit(ASIC)•which enab.'es the microinvaner to operate in between components grid-iced or oH-3rld:,odes This chip is built in advanced 55 mntechno(cgy with high-speed Mawunits per 2oA(L-Qba hcircuita 10 g digital lag_and has supernestresporres times to cmingtg loads and grid events.aR.,iating -Faster installation with simple two-wire AHJ: constraints on has sizing for home energy systems. cabNn9 Over olteg.icdhtADp n5 Town TI ITY:Southold OYsvNtagada,a A°pert UTILITY: - High Productivity and reliability 18 - AC port baokfeed current Produces power even when the grid is 1.0 PSEG LI down' Power factor setting /�/ More than one million cumulative hours Cdd-tied power is..,(adjustabla) o.561aading...o.bs legging DATE_12/2 V12g24 se Energy 5 oftestirlg Peekeffi.so., % g7.6 97-4 Part of the En pha gy ystam IQ8 Series DRAWN BY: IQ8 series Mictoinverters integrate with reliability standards with more than one Class It double-insulated enclosure CEC weighted Aficiency x 972 �'g the lQ Battery,10 Gateway,and the million cumulative hours of power-on .Optimized for the latest high-powered fbgmmapowarconsumption mw 22 29 FELIX GONZALEZ Enph.se App monitoring and analysis testing,enabling an industry-leading PV modules software. limited warranty of up to 25 years. Felix@leviathansolar.com Microgrid-forming Ar,wenitemparatur.m ga -4WCtoWC(-4(yFto14g•F) +1 809-703-7147 zE� Compiles with the latest advanced grid Relative humldtyrang. 4%to10oist—nd—ig) (iVtfsupport DCconrrectortype SnabliMC4 PLANS REVISIONS Remote automatic updates for the Dimenxions(H x W x W;Weight 212 mm(0.3'1><175 mm(eA1 x 302 mm(t21;1.1 kg(2.431bs) latest grid requirements •Configurable to support awide range Coding NaWralronvection-mfans Connect PV modules quickly and easilyas PV pf shutdown equip Unlisted of grid profiles Approved for wet locations:Pollutiondegm. ves:PD3 to the lQe Senesonnanverters that have as PVrm with equipment and 2 integrated MCA connectors. conform with various regulations when •Meets CA Rule 21(UL 1741-SA)and IEEE Enclosure Ctassndouble-insulated.rorrasmn-resistanipwymedcarwiosure -44-- installed according to the manufacturer's 1547:2018(UL1741-SB) NEMAT 6;ourdeor mstructiona Environ.category;UV exposve rating YPe Na e: 10x Series Mxsgnvenen wnmt Da mudtogaMm CA Rule l-1.ULList).UL62m9/,IEEE1547:2 18 qui(titnt e66),FCC Part 15 Class&4.NEC 03Class li C2020 estior,60.12 ardC •OMy whenmstalledMNip System cmrcrdler 2.maers UktM1. wlMpreWousgenvree oterpnaxmma'rnmters Certifications Thrs product sU..Isted as PV mpd shutdown equipment arM conforms with NEC 2014,NEC 2O17,aiW NEC 2D20 sett on 65012 and C22.i-2018 (l07 ser®viII65edeaaM so on)in ihasamesptem Rule 64218 rapdshutdownef PV systems for ACand DC oznduc when rcistaliedaccardingto themariutaeturer's insiruc4ons. , ronoann.oatl xrAcreDo. fpEC 9qC (2l Nomv,a volta9s range con6e WendaGDeyontlnmNnaiNrequkedhydauLEty. t� �}`3 S_ a ®2023E ph E rg Atl�F resmved e:PM1ase ihaeentl CCtogoc lQarA certanother marks6sietl at f3)lmas maY vary Reterto ocelrequNenremstadefi�w the m:mberol maonsenersperDrsnchmYourama 4 {�-,y i` �4-.i �.-.. -aq,� -= �:�-�-- tretlema.as of Enphexe FnergY m�'^a'e USaM Mhermwrtr IpBX-taCb-nxH-e0185-t6EN-Ux-2Q23-08-21 }( F 11 neawhiecibM Ae IOaC-MC4 pxN-no183-1.0-FN-Ux-2023-08-21 �g 02'_3 0 9f:EkEy4 Lat: 41.13bi5b13 ��) Lon:-72.321574 L U R-40Snap rack- - v UR-60 Solar Mounting Solutions + Ultra Rail LEVIATHAN SOLAR INC The Entire System is a Snap to Install 1993 Pond Rd,Ronkonkoma.NY 1177! • 31-553-2732 New Ultra Rail Mounts include snap-in brackets +1 viathansolar infoQleviathansola r.com for attaching rail •Compatible with all the SnapNrack Mid Clamps HI-65859 and End Clamps customers love — ( -Universal End Clamps and snap-in End Caps provide a clean look to the array edge TITLE: EQUIPMENT SPEC SHEETS Unparalleled Wire Management CUSTOMER NAME: •Open rail channel provides room for running Joyce Orrigo wires resulting in a long-lasting quality install CUSTOMER ADRRESS: •Industry best wire management offering 15925 Main Road includes Junction Boxes,Universal Wire East Marlon,NY 11939 Clamps,MLPE Attachment Kits,and Conduit Clamps AHJ: •System is fully bonded and listed to UL 2703 Town Of Southold Ultimate alp f Standard UTILITY: The PSEGLI DATE: 12/20/2024 • `• • •• • Heavy Duty UR-60 Rail DRAWN BY: . •- - • • +• •' •UR-60 rail profile provides increased span FELIX GONZALEZ capabilities for high wind speeds and snow loads Felix 1 809-703-7147�m • - •• • ° • • •• •Taller,stronger rail profile includes profile- + specific rail splice and end cap •All existing mounts,module clamps,and PLANS REVISIONS accessories are retained for the same great •s- o • install experience 2 -/--/-- s � a RESOURCES snapnrack.com/resourcesR � DESIGN snapnrack.comjconfigurator WHERE TO BUY snapnrack.com/where-to-buy Y 0 16 N �f1