Loading...
HomeMy WebLinkAbout47548-Z g1lffQl TOWN OF SOUTHOLD oo� M�oG BUILDING DEPARTMENT a TOWN CLERK'S OFFICE • SOUTHOLD, NY 0 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 47548 Date: 3/15/2022 Permission is hereby granted to: Town of Southold 53095 Route 25 PO BOX 1179 Southold, NY 11.971 To: construct bathroom alterations to existing recreational building. At premises located at: _ 970 Peconic Ln., Peconic "5 -a5 V D ( 0 ✓ SCTM #473889 '40� dl�rn et Sec/Block/Lot# 75.-1-15.2 Pursuant to application dated 2/3/2022 and approved by the Building Inspector. To expire on 9114/2023. Fees: Total: $0.00 Buil ing Inspector Nunemaker, Amanda From: Collins, Michael Sent: Wednesday, March 5, 2025 9:00 AM To: Nunemaker, Amanda Subject: RE: Permit renewal - Permit no-47548 - Rec center toilet rooms Attachments: Resolution 2025-199.pdf Confirmed From: Nunemaker, Amanda <Amanda.Nunemaker@town.southold.ny.us> Sent:Wednesday, March 5, 2025 8:06 AM To:Collins, Michael<michael.collins@town.southold.ny.us> Subject: RE: Permit renewal- Permit no-47548-Rec center toilet rooms Michael, Please confirm that I can void permit#47548 as a result of yesterday's Town Board meeting. From:Collins, Michael<michael.collins@town.southold.nv.us> Sent: Monday, March 3, 2025 8:00 AM To: Nunemaker,Amanda<Amanda.Nunemaker@town.southold.nv.us> Cc:Jacques Garant<Jgarant@lkma.com>; Chris Dwyer(cdwver@lkma.com)<cdwver@lkma.com> Subject: RE: Permit renewal- Permit no-47548- Rec center toilet rooms There is a resolution on for tomorrow to reject all bids for this project and the Town Board no longer plans to fund it. No need to continue working towards a renewal of the building permit. Michael From: Nunemaker,Amanda <Amanda.Nunemaker@town.southold.nv.us> Sent:Wednesday,January 15, 2025 2:16 PM To:Collins, Michael<michael.collins@town.southold.nv.us> Subject: RE: Permit renewal- Permit no-47548- Rec center toilet rooms Ok. From:Collins, Michael<michael.collins@town.southold.nv.us> Sent:Wednesday,January 15, 2025 2:14 PM To: Nunemaker,Amanda <Amanda.Nunemaker@town.southold.ny.us> Cc:Chris Dwyer<cdwver@lkma.com>; 'Jacques Garant'<Jearant@lkma.com> Subject: RE: Permit renewal- Permit no-47548- Rec center toilet rooms Amanda: Three signed and sealed sets of drawings are on the way to you via interoffice mail. 1 Michael Collins, P.E. Town Engineer Town of Southold (631) 765-1560 htti)://www.southoldtownny.gov/index.aspx?nid=l 95 CONFIDENTIALITY NOTICE: This communication with its contents may contain confidential and/or legally privileged information. It is solely for the use of the intended recipient(s). Unauthorized interception, review, use or disclosure is prohibited and may violate applicable laws including the Electronic Communications Privacy Act. If you are not the intended recipient, please contact the sender and destroy all copies of the communication. From:Jacques Garant<Jparant@lkma.com> Sent: Friday,January 10, 2025 9:48 AM To: Nunemaker,Amanda <Amanda.Nunemaker@town.southold.nv.us> Cc:Chris Dwyer<cdwyer@lkma.com> Subject: Permit renewal- Permit no-47548- Rec center toilet rooms Amanda; Regarding the Recreation Center ADA toilet rooms project: Attached please see permit application for the permit renewal for the recreation center toilet room renovations. I have also attached the drawings with small changes to ceramic tile and grout color. If there are any issues or comments please don't hesitate to contact us. Thank you. Jacques Garant AIA igarant@lkma.com L.K. McLean Associates Engineering&Surveying, DPC 437 South Country Road I Brookhaven NY 111719 t(631) 286-8668 `, Please consider the environment before printing this e-mail. ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 2 RESOLUTION 2025-199 ADOPTED DOC ID: 21131 THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION NO. 2025-199 WAS ADOPTED AT THE REGULAR MEETING OF THE SOUTHOLD TOWN BOARD ON MARCH 4, 2025: RESOLVED that the Town Board of the Town of Southold hereby rejects any and all bids received on February 20, 2025,pursuant to the bid for the Recreation Center Bathroom Renovations. Denis Noncarrow Southold Town Clerk RESULT: ADOPTED [UNANIMOUS] MOVER: Anne H. Smith, Councilperson SECONDER:Brian O. Mealy, Councilperson AYES: Mealy, Smith, Doherty, Evans, Doroski ABSENT: Albert J Krupski Jr . 1. FIEI.;D;NS,i, OTI�N NAP AZT DATA I'll ',. • : ••,. GbiVI'll Nx . . ro M. FOUNDAZ`ION;.(1ST).; fi c.-\—�.0...t( ,,,c y . qII -R, ,AKCIZ.� r4 ,..3 . . . *' ... . . •FOUNDATION(2ND)• M O s i .*.,.-'.,,.�,..,":.:�.x.,...I-.�.--v.,.,.-.:...;:,..,�..*..I....�,.?I."..:t,..m I..-.......,.'',..,�,—*...,.;".1,**�..�.:....1-:�.—;::.,...I'...:.I..::...,''....".-.-,;..::,...,,.,:1�,,..n'..:1:.:.....:.....*,�..-.,.1.�,.,.1..&I�,I..*I...�,�..;...:�II.m11-..1:....-:.:�..��...�...._.,—r 7......,...:�.�..;.I....�...I,:I,-.I..-.�:...'�...-....o.,�,6 iI",.;I...'--..q t�7,-:�—.'�:��—I.��I...4:.�.;..r.-4I:;-,.:�,..�w�.`.....';..I.:.I..'.:....,d:''—.?�,.t.:.�I.-.I.0..II..�,.�,.I,.�..:".-..,....,�..:....:..&I I-,-.--.i;,:..,..-.�..-....,',-.':&:!1:,..I.1....-..i.::......:j..:.".1*.r.,�...::%,.m,.......�...,;-,.-,.z.�.�,...,.I..II.-�.1,..'...-I;.,d.�,.d*'I4,,&,,..,P,�.-,...��I,:.��..,.,-*:.I.I�I..�.d..%0.I.....,:1-1.,....q....'..-.. .-,...:.;.....�,�...,-..q.:.�.-.:.m.....�.-..,�..:..,�...�.,i.-..&—..��:..w..,..O...d...�,:I.::,.�,.,.'::..".I.�j.,,.......:"-,�..i,,.;..'�,�..'I-.;..j.�I*.-.:..:i'.I..!..!..&�-.,.:....::,.:%'....�:.,t.:--I%...,...,i qq.*qdt..!.,&..i,..:�..'..::-.�dI......,..d. .-.,,�—.'1..:..:.-...;.,.-I,-.-...:.:�".�,.:�....d..%......I-...:�.,.,....,..�1.I.�q...�:1�d...�d....:I...��>....;�.......::.d-:�..."--%�1*.r.I.�...1,.I�.I..-.1,:.....:,.t.�..q:;.1.�:,�I�;"�"I�..-"-:....'�.d.:,�..�.�...,�,,...'.�...I..:—:;..';.....:*.:.,.,:.�.*..-.,..-.eI::,:I...:.;...,,,�..,�.'.�,::.1�.:'l:..q m.-�I-':'�—*-..-�.:.-I......*,:.,:...:...�.-.I I....1,....%...'",-��-;.:.:...t,"q::�.�..;:*...k.:..,,.,&.,,,.�...I.'r.,I,,,*,.�...,�:�.�-1,'.%.,�1.-....1..,:.:�;�.;:�.�IL'.::�1.,,.�*::....��,';,:,,.,,-rr...I�:..,....,..�.::1I...:.,�.;.,...-;;::�%��I�.;l'4.�.I1.,.;-�:':�,.....,.1q.q m,.I.1�1�.,.I.-,�-.*:.�r..I 1 r�.:,.,.%.�:�.::.����r—....I:.�q..:�:r..�:.`:,,�..I;:'�..-;.�%%1�,.r..'..�..,:,..";;!.!�-:I,,.",.-.—..I.,q"'..�b....�.,I::,'..,�:�;;.,:::L%.:.,I�:���.-...�I..�..%..-:��dd:",�,,..��.!1.1,.1:,.:�'.,.��,,,:,,:��,',�...�.�:.�,�.1:::':.4�Ii*,..;."�'����-�.;;;.,�-,�:��7:t'—,...�'..r-.,,;i:�-..'�'...,'1.,,...j.,,!..I.":.....A� y x+ f r t ' - O9 4. J a. t b; < _ v l } ��i't i t sn H „ t ��rF an ROUGH FRA1yIING ti PLUMS° 1:G' 3 ,.q , fir` r ,� 1 + ZS 4 • ' f y ytl§ jL7 • i -V t Z t . . . . \ l.. ¢ I r I "Y + •. r INSULATION p12N: '.. .' . H STATE ENRGY`C013 ' . . x • 1 r - � t a. i . k FINAL ... .z ' ' d` a ,,, tr < 5 . . . t11 t t l E t}� f. : , D o �. . 5 y 1 , e. - C w 1 f 5 , d`t . S ,, 4 . 4 . , ..:,. ', .. .. .: F`t YI Z • . r . '( 1 Z . 1,}..' . . q,*S 1 SY x t ,\ , y a .—�?"I..�..,' C . R l J ' .':' .t� r 1 1 4M �=.r.f, \ ., II �y Y t 1,.rr t . 4 y l . t .t .- i.NI..t�.f .. . ..<. .. 'ooSUFFoi;�o` ; TOWN.OF SOUTHOLD—BUELDING-DEPARTNIENT Town Hall Annex 54375 Main Road-P. O.,Box 1179 Southold,NY 11971-0959 • �:` Telephone 631 765-1802 Fax 631 765=9502 h s //www.southoldtownn ov y P ( ) ( ) Date Received APPLICATION FOR BUILDING -PERMIT For Office Use Only PERMIT NO. Building Inspector: FEB ® 3 2022 lip Applications and.focros must be:fllled out in their entirety.Incomplete TOWNOFN�_r't. t �� applications will not-be accepted. Applicant is not the owner,an SOUTHO C)Wner's Authorisation form(Page 2)shall be completed. Date: 5 � OWNEIt((S)--O•F PROPERTY: Name: �� �®� �� SCTM#1000- CP75,6 '04 Old — 621S.ME, Project Address: D Phone#: 631-765-1560 Email: michael.coilins@town.southold.ny.us Mailing Address: 53095 Route 25 Southold NY 1-1971 Michael CONTACT PERSON: Name: Michael Collins P.E., Southold Town Engineer Mailing Address: 53095 Route 25 Southold NY 1-1971 Phone#: 631-765-1560 Email: michael.coil ins town.southold.n :us DESIGN PROFESSIONAL INFORMATION: Name: ��Gr�� S (fir¢/� %/i� �•�;�/'�: •� .4<,�S �G Mailing Address: Phone 9-8,66S Email: CONTRACTOR INFORMATION: Name: TO BE DETERMINED Mailing Address:- Phone M Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition AAlteration ❑Repair ❑Demolition Esti ated Cost of Project: ❑Other $ , o�> Will the lot be re-graded? ❑YesNo Will excess-fill be removed from premises? ❑YesNo 1 PROPERTY INFORMATION Existing use of property/r7, ',�� intended use of properly: Zone or use district in which premises is situated: Are there any covenants and-restrictions-with:respect to this property? DYesNo -IF YES;PROVIDE A.COPY. ❑ Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department foe the issuance of a Building.Permit,pursuant to the Bullding.Zone . . . ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction.of buildings, . addl lons,alterations or for removal or demolition as hereln described.The appUcant agrees to comply with all applicable lams,ordinances,building code; housing code and regulations and to admlt authorized Inspectors on premises and In bullding(s)'for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. (print name): A-6i / ❑Owner Application Submitted By(pri a e :) � d� Authorized Agent Signature of Applicant- Dater 2 STATE OF NEW YORK) SS: COUNTY OF _�,11CjC0 t(L ) being duly sworn,deposes and says that(s)he is the applicant (Name of Individual signing contract)above named, (S)he is the �o (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have'performed the said work and to make and file this:- application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I cy� J da of 20 72 Notary Pubic CHRIS nNE WIEGAND. PROPERTY OWNER AUTHORIZATION NOTARYP LIC,State.ofNewYork No.Mj Wi8210359,Suffolk•Coun (Where the applicant is not the owner) Cornmisslon ExplresAugust 17Z residing at do hereby authorize to apply on- my behalf to th Town of Southold Building Department for approval as described herein. a.a Owner's Signature- Date �c-D- q ve�55 �J Print Owner's Name 2 TOWN OF SOUTHOLD—BUILDING DEPARTMENT . Town Hall Annex 54375-Main Road P. O.'Box.1179 Southold,NY.1-1971-0959..Wes • Tel hone(631)765-1802 Fax(631) 765-9502 https://www.southoldtownn gov -BUILDING PERMIT APPLICATION INSTRUCTIONS&CHECKLIST • ' Applications and forms must be filled out in their entirety. Incomplete applications-Will not-be accepted.' The work covered by this application, including land clearing/site work, may not be-commenced before- issuance-of.a building permit. • No building shall be occupied or used in whole or in part for any purpose whatsoever until..the Building Inspector issues a Certificate of Occupancy. • Every building permit shall expire if the-work authorized has not commenced within twelve (12). months after the date of issuance or has not been completed within eighteen-(18) months from such date. If-no zoning amendments or other regulations affecting the property have-been enacted.in:the interim,the Building Inspector may authorize; in writing,the-extension of the permitfor an .additional 6.months. Thereafter, a new permit shall be required. ALL APPLICA14ONS MUST BE SUBMITTED WITH THE FOLLOWING-MATERIALS: Building Permit Application: Complete;signed and notarized. EIA survey/site plan, drawn to scale at original size, showing the location of lot and of buildings.on.- p?Four ses, relationship to adjoining premises or public streets or areas and waterways. (4)sets of plans bearing the signature and original.seal of a NYS licensed professional-engineer or architect illustrating compliance with the Building Codes of New York State. ❑Contractor's proof of insurance and Suffolk County license: • Certificate of Workers' Compensation Insurance (C105.2 or U26.3)AND a:Certificate of Disability Benefits Compensation Insurance (DB120.1) . • Certificate of Liability Insurance "Note: Final Fees will be calculated by the Building Department using the.fee schedule. Fees will be. collected after the permit is written" ADDITIONAL DOCUMENTATION MAY BE REQUIRED AS IDENTIFIED BELOW: ❑Suffolk County Department of Health Services Approval (original copy) ❑Approval of the Zoning Board.of Appeals, Planning Board, and/or Historic Preservation-Commission (if applicable) ❑Electrical Permit Application (FILED SEPERATELY): Electrician must have an active license with Suffolk County ❑Flood Plain Development Permit Application (if applicable) ❑Southold Town Trustees Permits may be required: If any work will be done within 100'.of a tidal or fresh water wetland. ❑NYS D.E.C. Permits may be required: If any work will be done within 300' of a tidal wetland or 100' of a fresh water wetland ❑l copy of ComCheck/ResCheck (if applicable) ❑1 copy of Manual 1, Manual D and Manual.S (if applicable) ❑Utilization of truss/pre-engineered wood/timber construction form (if applicable) ❑Single and separate title search (if applicable) ❑Curb cut permit(NYS or Suffolk County form 239F)-(if applicable) ❑Original signed Owners Authorization: if applicant is other than owner. . .3 LK&A L. K. MtLEAN ASSOCIATES, P.C. �Al LETTER OF TRANSMITTAL CONSULTING ENGINEERS ;t� �� DATE: 02/01/22 1 PRO1 NO.: 21193.000 437 SOUTH COUNTRY ROA ATT: Amanda Nunemaker BROOKHAVEN,NEW YORK 11 �EB 3 � RE: Town of Southold Recreation Center 970 Peconic Lane TO: Amanda Nunemaker B%OF SOtI-To(' ` Peconic,NY 11958 Town of Southold Building Department TOW 5437S Main Road Southold,NY 11971 We are sending you 5-1 Attached 0 Under separate cover via the following items: Shop Drawings Prints X Plans Samples Specifications Copy of Letter Change Order Other: Copies Date No.Sheets Description 4 2/2/2022 7 Recreation Center Bathroom Renovation Permit Set 1 2/2/2022 4 Permit Application These are transmitted as checked below: For Approval Approved as Noted Resubmit Copies for Approval For Your Use Returned for Corrections Submit Copies for Distribution As Requested No Exception Taken Make Corrections as Noted For Review and Comment X Other: For Permit For Bids Due Prints Returned After Loan to Us REMARKS: C.Dwyer M.Collins,T.O.S. Copy To: LKMA File Signed: 1 L. K..McLEAN ASSOCIATES, P.C. LETTER OF TRANSMITTAL CONSULTING ENGINEERS DATE:.; 02/11/22 PROD NO.: 21193.000 43TSOUTH.COUNTRY ROAD ATT: Amanda Nunemaker BROOKHAVEN;"NEW YORK 11719.: :. RE: Town of Southold Recreation Center. 1 1• 970 Peconic Lane. TO: Amanda Nunemaker Peconic,NY 11958' Town of Southold Building Department :54375 Main Road Southold,NY 11971 We are sending you Attached Under.separate cover via the following:items: - Shop Drawings Prints X Plans Samples Specifications Copy of Letter. Change.Order Other: Copies Date No.Sheets 'Description 4 2/11/2022.: 7 Recreation Center Bathroom Renovation Permit Set revised 1 2/11/2022 4 Permit Application i I. These are transmitted as checked below: For Approval: Approved as Noted Resubmit Copies for Approval 'For Your Use Retdrned:for,Corrections Submit Copies for Distribution As Requested No Exception Taken Make.Corrections as Noted: For Review and Comment X Other: For Permit For Bids Due Prints Returned After Loan to Us REMARKS: C.Dwyer M.Collins,T.O.S. Copy To: LKMA File Signed: IVY I LETTERDF TRANSMITTALL. K. McLEAN ASSOCIATES,,P.C. CONSULTING ENGINEERS 02/11/22 1 PROJ NO.: 21193.000 ECElyE 437 SOUTH COUNTRY ROA D: A Amanda Nunemaker BROOKHAVEN,NEW YORK 1 AqA❑❑ 1 1 qn RE Town of Southold Recreation Center -MAR I� 4 20?2- 970 Peconiclane TO: Amanda Nuriemaker Peconic,NY 11958 ILDING DEPT. Town of Southold Building Department 10101 OF SOUTHOLD 54375 Main Road Southold,NY 11971 We are sending you �X Attached Under separate cover via the following items: Shop Drawings Prints X Plans Samples Specifications Copy of Letter Change Order Other: 1 Copies Date No.Sheets Description 4 2/11/2022 7 Recreation Center Bathroom Renovation Permit Set revised 1 2/11/2012 4 Permit Application These are transmitted as checked below: For Approval Approved as Noted Resubmit Copies for Approval For Your Use Returned for Corrections Submit Copies for Distribution As Requested No Exception Taken: Make.Corrections as.Noted For Review and Comment X Other: For Permit 'For Bids Due Prints Returned After , Loan to Us REMARKS: C.Dwyer . M.Collins,T.O.S. Copy To: LKMA File Signed: ' ARCHITECT: C� APPROVED AS NOTED OCCUPANCY OR USE IS UNLAWFUL DATE:� '� B.P.# SASS► iTNQUT CERTIFICATE L. K. McLEAN ASSOCIATES, P.C. FEE: CONSULTING ENGINEERS 437 SOUTH COUNTRY RD., BROOKHAVEN, NEW YORK 11719 OF OCCUPANCY NOT BUILDING �:E°�;r;TM,ENT AT 765-1802 8 AM TO •i F A9 FOR THE I U 1 Z50 1 U U C U U FOLLOWING INSPECTIONS: IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE 1• FOUNDATION - TWO REQUIRED DIRECTION OF A LICENSED ARCHITECT ENGINEER,TO ALTER IN ANY WAY ANY FOR POURED CONCRETE � �� ��S�ECTIO�� ITEM ON THESE DRAWINGS. IF E ITEM BEARING THE SEAL R H ARCHITECT/ O REQUIRED EEFOR� ATHET ENGINEER IS ALTERED,THE ALTERING ARCHITECTS ENGINEER SHALL AFFIX TO 2, ROUGH - FRAMING & PLUMBING HIS,MER ITEM 'THEIR SEAL AND 'THE NOTATION 'ALTERED BY" FOLLOWED BY 3. INSULATION �C 41� HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC Or.� ���� DESCRIPTION OF THE ALTERATION ON THE DRAWING. " THE PLAN A 4. FINAL - CONSTRUCTION MUST s AND SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A E COMPLETE FOR C.O. RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L K. ALL CONSTRUCTIONTC3 to McLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE SHALL MEET THE L���■�■a4+/��� � '� "' � SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY REQUIREMENT' OF THE CODES OF NEW INSPECTION ;EOUIRED ;i' ""'����i� ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES, US YORK STATE. NOT RESPONSIBLE FORPC DESIGN OR CONSTRUCTION ERRORS. "��� © L.K. McLEAN ASSOCIATES, P.C. ,,,,, �' CONSULTANT: COMPLY WITH ALL CODES OF PLUMBER CERTIFICATION NEW YORK STATE & TOWN CODES ON LEAD CONTENT BEFORE � � �' % '--- � AD AS REQUIRED AND CONDITIONS OF ���. `-- ��� ���'�� - � ;< CERTIFICATEOFOCCUPANCI %'` °". , '� ,`/ I""w AREA OF WORK 335 S.F. - A SOLDER USED IN WATER 4 /" PROVIDE !'dG BOARD SUPPLY SYSTEM CANNOT '' %/ ' � � — RECREATION OFFICE G' / � , !: / - � � TEMPORARY / TOILETS TO REMAIN ACTIVE; / � / / / g PROTECT OFFICE S�`�t�"R' 9USTEES EXCEED 2/10 OF 1/ LEAD. i /: I � � � >,./r ;> �"' � � ;%,�% ., ,.'" dam''. r, .. �' %/ EXISTING I u / ELECTRIC STAFF AND rlrr��'ofl CLOSET DQUIPMENT UST AND DEBRIS CONSULTANT: ! ( �% ./,:._a v! / ra CONTRACTOR PLMOIB ��. BWGV'JAStE 4 %: / /' I % �� ,,' � �� �,` / � BUILDING ti ACCESS VV TER LINES NEED`- / Ile TE:I`IN .BEFOPUE CG\IER1 " ws .�.. „� /� , m, a 0 CONTRACTOR CONSULTANT: i' r. , �. �/� CONSTRUCTION ' "" " •, MAXIMUM OCCUPANT COUNT = 371 ZONE; CORDONE � OFF FROM PUBLIC s PERSONS WITH TEMPORARY WALL %. MULTI FUNCTION SPACE TO REMAIN FUNCTIONAL; PROTECT FROM DUST AND DEBRIS. COORDINATE WITH OWNER'S SCHEDULE TO ELIMINATE PROGRAMMATIC PROJECT: 970PECONICLANECONFLICTS TOWN OF SOUTHOLD ('''► RECREATION CENTER PECOIto IN V , N .Y. 11958 SUFFOLK COUNTY, NY TAX MAP NUMBER DISTRICT: 1000 BATHROOM CONTRACTOR ACCESS SECTION: 075.00 RENOVATIONS BLOCK: 01 .00 LOT: 015.002 970 PECONIC LANE MINUMUM NUMBER OF REQUIRED PECONIC, N.Y. 11958 Q D TOILET FIXTURES BUILDING AREA = 6,925 SF - ISSUES/REVISIONS NYSBC TABLE 1004.5; NYSPC TABLE 403.1 Description No. Date OCCUPANT LOAD = STATED OCCUPANCY = 371 (USE 372) 50-50 GENDER RULE 186 MALE OCCUPANTS 186 FEMALE OCCUPANTS MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES PER TABLE 2902.1 ASSUME 372 TOTAL OCCUPANTS 50/50 GENDER COUNT WATER CLOSETS (WC) LAVATORIES (LAV) DRINKING FOUNTAINS (DF) OTHER (SERVICE SINK) MALE FEMALE MALE FEMALE ASSEMBLY 186 OCCUPANTS 186 OCCUPANTS 186 OCCUPANTS 186 OCCUPANTS 1/100 = 1 DF 1 REQUIRED PECONIC LANE 1/125 = 2 WC 1/65 = 3 WC 1/200 = 1 LAV 1/200 = 1 LAV PERMIT NOTES REQUIRED 2 WC TOTAL 3 WC TOTAL 1 LAV TOTAL 1 LAV TOTAL 1 DF TOTAL EXISTING 1 SERVICE SINK TOTAL PLUMBING FIXTURES EXISTING SITE PLAN 1. FIRE ALARM SYSTEM NOT TO BE EFFECTED DURING CONSTRUCTION TOTAL 2. ALL CONSTRUCTION SHALL COMPLY WITH ICC/ANSI A117.1-2009 ACTUAL 3 WC TOTAL 3 WC TOTAL 1 LAV TOTAL 1 LAV TOTAL 1 DF TOTAL 1 SERVICE SINK TOTAL PLUMBING FIXTURES TOTAL COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES AERIAL MAP I AN '190 Adzl: , SYMBOLS LEGEND ABBREVIATIONS , RAWING SHEET INDEX A. EACH HT. HEIGHT P.S.F.. . . POUNDS PER SQ. FOOT o ;. „� "'' �,'"" / : "'yr SYMBOL DESCRIPTION SYMBOL DESCRIPTION APPV'D. APPROVED E.C. ELECTRIC CONTRACTOR H.W. HOT WATER RECEPT. RECEPTACLE LU J,:: r %` %% BD. BOARD ELEV. ELEVATION INSUL. INSULATION REQ'D. REQUIRED v;;, .,, r TEMP TOILETS;:e'" ;�i' .° ": All BOT. BOTTOM SECTION NUMBER ELECT. ELECTRIC INV. INVERT REINF. REINFORCED 3 �..:',.� ®.''� SHEET N0. SHEET DESCRIPTION B.O. BOTTOM OF EXIST. EXISTING JT. JOINT RES. RESILIENT x SECTION X-X FINISH TAG / B/0 BY OTHERS EQ. EQUAL L.P. LOW POINT RM. ROOM rA SHEET NUMBER BLDG. BUILDING EQUIP. EQUIPMENT LTG. LIGHTING SECT. SECTION GENERAL j ,. , ,/;, '/ ,:,,,/, s' ✓" :,,�; ..., r . / . ' '' AREA OF TOILET ,i':;', . - , ROOM WORK - EXH. EXHAUST LAV. LAVATORY S/C SELF CLOSING CO 1 COVER SHEET r / - BLKG. BLOCKING,Cn 0/ y r M SPECIFICATIONS ' DETAIL NUMBER , ,; <;/','�" �'% � r/' < �. FL FLOOR MAX MAXIMUM P ; / C.T. CERAMIC TILE GN 1 GENERAL NOTES-1 F.D. FLOOR DRAIN Mlt. METAL STL. STEEL �� .: ;•„ ,i .. ''; ;�",,;:' ::._: ',yam GN-2 ICC/ANSI A117.1 2009 ACCESSIBILITY STANDARDS DRAWING TITLE. s; CLO. CLOSET FIN, FINISH MFG. MANUFACTURER STRUCT. STRUCTURAL CONTRACTOR ACCESS y ;i ; , X DETAIL TAG O WINDOW TAG r' �'- ;';:"" /�' CLG. CEILING FIXT. FIXTURE MAS. MASONRY SUSP. SUSPENDED E �y %; / �'`„ ' ..:�,, moo,. „%;, r',' :.`. ;'. �;. %. i o � ,�� �,' '°/. �,,.y �, :>! .' / ' i' .a ." ..., . � ; r,��j�o' " yjj'".,'",,/,/ ; �% „ SHEET NUMBER r, o /. v , //i /, / ,� / COL. COLUMN FDN. FOUNDATION MAT. MATERIAL T & B TOP AND BOTTOM ARCHITECTURAL COVER CONT. CONTINUOUS FTG. FOOTING MIN. MINIMUM T & G TONGUE & GROVE SHEET DM-1 DEMOLITION PLAN �- . r / T F E FIRE EXTINGUISHER MECH. MECHANICAL T.O.S. TOP OF SLAB ymi _ % "", �„ ELEVATION NUMBER - �-. � ,; ,, '°%. ;, � % v� / ON PLAN - /: r' / C.W. COLD WATER GALV. GALVANIZED M.O. MASONRY OPENING TYR TYPICAL A 1 CONSTRUCIT ,'%.' � .�,,;.. AREA OF WORK�. � ' ;' ., �., , _ E ': ''"'�/ % " "y, =' ELEVATION TAG X PARTITION TYPE CONC. CONCRETE2 DETAILS AND SCHEDULES p � � ��/ - ��,"i�', ,�,-,'',.; �.. ��:' x G.C. GENERAL CONTRACTOR NO. NUMBER V.I.F.V.LF. VERIFY IN FIELD cal -� „ .. i ;" ;.: '%e 9 .� .. �, SEAL & IPV6T�.JRE: Design By: JG F '° ': �. /�,' C.B. CATCH BASIN GYP BD. GYPSUM BOARD N.I.C. NOT IN CONTRACT VERT. VERTICAL P-1 PLUMBING RISER DIAGRAMS S i rn c1 „ /;;. ,i SHEET NUMBER a, ,�;� b � � �C Drawn By: JG/JR ' Dra ,F ,. ; ,� �,;::�. : .: DBL DOUBLE 4ULEP �- Approved By: JG o /,' r: :w, / s / %'.. '. HDR. HEADER OPEN'G. OPENING VEST. VENT ROOF r. 5��;� ��G> G I � �� ��� _�" ,. � / / �: r � � '�� � y' � a Scale: AS NOTED - ..., r :, ,�:, DIA Di P.C. PLUMBING CONTRACTOR�:,' �,,,,,> .,,.., R a Date: ET DETAIL N o ;..✓ : �:` ,:`,.:'"�,r�,°,,, , r ":% ,.�'"� ,,,',. � � � ,,'., / „ x DIAMETER H.M. HOLLOW METAL W.P. WATERPROOF ,, , ,," F,e , ,,, TNT. ELEVATION NUMBER ;� �r; - ��,���r, ,•,� MARCH 2O22 cv �' i. � _ %' y" ' '' ;/� /.: / P.L. PROPERTY LINE < ' r`, ;r x o ,:,.: /' o ,. /., '. % .:`� r,;,% � �,.: , .", / . �,� �,,'��."., ",�,. HVAC HEATING, VENTILATION W/ WITH �' -��-"�+� w F U ri L xE EATI N EIN o / ,� File No: 21193.000 N _ INTERIOR ELEVATION (D & AIR CONDITIONING PL LAM. PLASI1C LAMINATE �� "' !� DOOR TAG CLOSET E Sheet No. ,,, , ': '� , DWG DRAWING W C WATER / S ' is ' ::.. ' �'v y ' <y/ ' x HD. HOOD / . r !,' EACH WAY, , SHEET NUMBER E/W WOOD ® /' �t '`;�' :../, ,� ,,, . �" �' �,�,:;� ...':;;�. PLYWD PLYWOOD PEAR � 2072 ` N 6 HORIZON. HORIZONTAL P.S.I. POUNDS PER SQ. INCH QT. QUARRY TILE C O — o :2 n BUILDING DEPT. -znt ITH LD PLOT SIZE: 24" X 36" GENERAL NOTES DEMOLITION NOTES SAFEGUARDS DURING PLUMBING ELECTRICAL ARCHITECT: 1. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND 1. THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS AS REQUIRED IN CONSTRUCTION 1. ALL PLUMBING WORK UNDER THIS CONTRACT SHALL CONFORM TO THE 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD CONDITIONS TO STATE CODES. ORDER TO COMPLETELY DEMOLISH AND REMOVE ALL OF THE ITEMS NECESSARY CURRENT LOCAL PLUMBING CODE AND THE BUILDING CODES OF NEW YORK ASCERTAIN THAT ALL ITEMS ARE INSTALLED IN COMPLIANCE WITH THE (NFPA mmmoKk%, A% 2. ALTHOUGH THESE PLANS ARE DRAWN TO SCALE, NO DIMENSIONS SHALL BE TO COMPLETE THE WORK WHETHER OR NOT IT IS SHOWN ON THE PLANS OR 1. THE PROVISIONS OF THE BUILDING CODE OF NEW YORK STATE CHAPTER 33, STATE AND LOCAL JURISDICTION.. 70) NATIONAL ELECTRICAL CODE, THE 2020 NYS BUILDING CODE, ITS SCALED. DESCRIBED IN THE SPECIFICATIONS. SAFEGUARDS DURING CONSTRUCTION, SHALL GOVERN THE CONDUCT OF ALL 2. ALL MATERIALS SHALL BE NEW UNLESS NOTED OTHERWISE. REFERENCED CODES AND STANDARDS, AND LOCAL JURISDICTION. 3. NO NOTE OR DETAIL OR LACK THEREOF SHALL BE CONSTRUED AS RELIEVING 2• THE CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHT AND CONSTRUCTION OPERATIONS WITH REGARD TO THE SAFETY OF THE PUBLIC 3. THE PLUMBING CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL LABOR 2• IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO CALL FOR L. K. McLEAN ASSOCIATES, P.C. THE CONTRACTOR FROM 'THE EXECUTION OF THE WORK IN ACCORDANCE WITH POWER THROUGHOUT THE SPACE UNDER DEMOLITION'S REQUIRED TO PERFORM AND PROPERTY. FOR THE PURPOSE OF CHAPTER 33, CONSTRUCTION AND MATERIALS INSTALLED UNDER THIS CONTRACT AND SHALL GUARANTEE FINISHED WORK, COMPLETE, TESTED AND READY FOR OPERATION. CONSULTING ENGINEERS 437 SOUTH COUNTRY RD., BROOKHAVEN, NEW YORK 11719 ALL STATE AND/OR LOCAL CODES. SHOULD ANYTHING BE OMITTED FROM HIS WORK. OPERATIONS SHALL INCLUDE EXCAVATION, ERECTION, ALTERATION, REPAIR, THE WORK PERFORMED UNDER THIS CONTRACT FOR A PERIOD OF EIGHTEEN 3. IT IS NOT INTENDED FOR THE DRAWINGS TO SHOW EVERY WIRE, CONDUIT OR THE DRAWINGS, NECESSARY TO THE PROPER CONSTRUCTION OF THE WORK, 3. UPON COMPLE11ON OF DEMOLITION WORK, THE CONTRACTOR SHALL PROVIDE REMOVAL AND DEMOLITION AS RELATED TO BUILDINGS, FOR REGULATIONS (18) MONTHS FROM THE DATE OF COMPLETION OF HIS WORK. MINOR DETAIL AND IT IS UNDERSTOOD THAT WHILE THE DRAWINGS MUST BE HEREIN DESCRIBED, IT SHALL BE THE DUTY OF THE CONTRACTOR TO NOTIFY THAT ALL AREAS BE LEFT BROOM CLEAN. RELATING TO THE SAFETY OF PERSONS EMPLOYED IN SUCH CONSTRUCTION 4. THE PLUMBING CONTRACTOR SHALL CONSULT AND COOPERATE WITH THE FOLLOWED AS CLOSELY AS FIELD CONDITIONS WILL PERMIT, THE SYSTEMS THE ARCHITECT/ENGINEER. 4. ALL ITEMS NOT BEING REUSED OR RETURNED TO THE BUILDING SHALL BE OPERATIONS, THE PROVISIONS OF SUBCHAPTER TEN OF THE LABOR LAW AS GENERAL CONTRACTOR, HEATING CONTRACTOR, ELECTRICAL CONTRACTOR, ETC. SHALL BE INSTALLED PROPERLY AND ACCORDING TO THE INTENT OF THE IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE IN ORDER TO AVOID INTERFERENCE DURING INSTALLATION OF WORK. DIRECTION OF A LICENSED ARCHITECT ENGINEER, TO ALTER IN ANY WAY ANY 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. REMOVED FROM THE PREMISES, AND DISCARDED OUTSIDE OF THE VILLAGE IMPLEMENTED BY THE INDUSTRIAL CODE OF THE STATE OF NEW YORK, CONTRACT DOCUMENTS AND ACCORDANCE TO INDUSTRY STANDARDS AND GOOD ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER BOUNDARY, NO STOCKPILING OF ANY MATERIALS WILL BE PERMITTED UNLESS PART 23 PROTECTION IN CONSTRUCTION DEMOLITION AND EXCAVATION 5. THE PLUMBING CONTRACTOR SHALL PREPARE AND FILE ALL REQUIRED PLANS PRACTICE. ENGINEER IS ALTERED, THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO BEFORE PROCEEDING. WRITTEN AUTHORIZATION S GIVEN BY THE VILLAGE. OPERATIONS". SHALL APPLY. AND PERMITS WITH THE LOCAL AUTHORITIES AND SHALL PAY ALL FILING FEES 4. AT THE END OF THE CONTRACT THE CONTRACTOR SHALL PROVIDE THE OWNER HIS/HER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY' FOLLOWED BY AS REQUIRED. HE SHALL OBTAIN ALL WORK PERMITS AND WRITE-OFFS AS HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC 5. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY UNRELIEVED BY REVIEW OF 5. THE CONTRACTOR SHALL REMOVE ALL WALL CONDUITS LEFT AFTER WALL 2. THE CONTRACTOR SHALL INSTITUTE AND MAINTAIN SAFETY MEASURES AND AN UNDERWRITERS CERTIFICATE FROM AN ELECTRICAL UNDERWRITER APPROVED DESCRIPTION OF THE ALTERATION ON THE DRAWING. " THE PLANS AND SHOP DRAWINGS OR PERIODIC OBSERVATION OF CONSTRUCTION, FOR DEMOLITION, INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY OTHER PROVIDE ALL EQUIPMENT OR TEMPORARY CONSTRUCTION NECESSARY TO REQUIRED TO EXECUTE THIS WORK IN A LEGAL MANNER. BY THE AUTHORITY HAVING JURISDICTION AND PROVIDE A COPY TO THE TOWN SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A COMPLIANCE WITH THE CONTRACT DOCUMENTS, FOR FABRICATION PROCESSES TELEPHONE OR ELECTRICAL WIRING AND EQUIPMENT. SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY THE CONTRACTORS 6. THE PLUMBING CONTRACTOR SHALL FURNISH TO THE OWNER ALL CERTIFICATES UPON COMPLETION OF THE INSTALLATION. RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. McLEANAND CONSTRUCTION TECHNIQUES AND FOR SAFE CONDITIONS ON THE JOB 6. THE CONTRACTOR SHALL REMOVE ALL EXISTING FINISHED FLOORING INCLUDING OPERATIONS. OF INSURANCE REQUIRED BY LAW. 5. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE RESPONSIBLE SUBJECT ASSOCIATES, HT THESE PLANS AND SPECIFICATIONS WILL SE THE 7. THE PLUMBING CONTRACTOR SHALL PURGE AND DISINFECT ALL NEW DOMESTIC SUBJECT OF H COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY SITE. TILE, COMPOSITION TILE, ADHESIVES, CARPETING, TACTLESS, ETC. 3. THE CONTRACTOR SHALL PROVIDE WARNING SIGNS, FENCES AND OTHER ITEMS TRADES TO CUT AND PATCH REPAIR ALL WALL CEILING AND FLOOR ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC 6. THE CONTRACTOR IS SOLI7LY RESPONSIBLE FOR MEANS AND METHODS OF 7. IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACTLESS, AS REQUIRED FOR THE PROPER PROTECTION OF WORKMEN ENGAGED IN PLUMBING PIPING AND ANY AFFECTED EXISTING PIPING, IN ACCORDANCE WITH PENETRATIONS TO MATCH EXISTING MATERIAL AND FINISHES. CONSTRUCTION AND FOR SEQUENCES AND PROCEDURES TO BE USED. PARTITIONS ETC.) CAUSES AN UNEVENNESS IN THE FINISHED CONCRETE SLAB DEMOLITION OR CONSTRUCTION OPERATIONS, THE PUBLIC AND ADJACENT THE LOCAL AUTHORITY HAVING JURISDICTION. 6. ALL FIRE RATED ASSEMBLIES MUST BE FIRE STOPPED (MINIMUM 2 HOURS); Qc L.K. McLEAN ASSOCIATES, P.C. 7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY U1ILITY LOCATIONS AS THE CONTRACTOR SHALL PATCH TO LEVEL THE SLAB TO RECEIVE NEW CONSTRUCTION. 8. THE PLUMBING CONTRACTOR SHALL INSTALL ALL PIPING CONCEALED IN WALLS SUBMIT U.L. DETAIL FOR APPROVAL WELL AS OTHER UTILITY LOCATIONS THAT MAY OR MAY NOT BE SHOWN. FINISHED FLOOR. 4. THE CONTRACTOR SHALL NOT CLOSE OR OBSTRUCT WALKWAYS, AND OR CEILINGS UNLESS OTHERWISE INDICATED. EXPOSED PIPING SHALL BE 7• ALL MATERIALS AND EQUIPMENT SHALL BE LISTED AND INSTALLED PER THE CONSULTANT: 8. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF 8. THE CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISH SURFACES ALL PASSAGEWAYS, OR STAIRWAYS. THE CONTRACTOR SHALL NOT STORE OR NEATLY RUN PARALLEL OR PERPENDICULAR TO WALLS AND CEILINGS. PIPING MANUFACTURER'S WRITTEN INSTRUCTIONS. EIGHTEEN (18) MONTHS AFTER COMPLETION BY THE CONTRACTOR. THE PROJECTING PLUMBING, ELECTRICAL, TELEPHONE AND ALL OTHER PROJECTING PLACE MATERIALS IN PASSAGEWAYS, STAIRS, OR OTHER MEANS OF EGRESS. ABOVE ACCESSIBLE CEILINGS SHALL ALLOW THE REMOVAL OF CEILING TILES FOR PLENUM ACCESS. 8• FINISHES AND COLOR SELECTION OF MATERIALS, DEVICES, EQUIPMENT, AND CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THE GUARANTEE. ITEMS WHICH ARE BEING ABANDONED. 5. NO STRUCTURE, DEVICE OR CONSTRUCTION EQUIPMENT, WHETHER PERMANENT THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO ALL FIXTURES FROM MANUFACTURERS STANDARD RANGE SHALL SELECTED AND 9. 9. ALL MATERIALS SHALL BE' NEW UNLESS OTHERWISE SHOWN. ALL 9. DEMOLITION WORK SHALL BE DONE IN STRICT CONFORMANCE WITH LOCAL OR TEMPORARY, INCLUDING ALL PARTLY OR FULLY COMPLETED ELEMENTS OR PLUMBING EQUIPMENT REGARDLESS OF WHETHER SHOWN HEREIN WITHOUT ANY VERIFIED BY THE OWNER. WORKMANSHIP SHALL BE FIRST CLASS. AND STATE REGULATIONS. SECTIONS OF THE BUILDING, SHALL BE LOADED IN EXCESS OF ITS DESIGN 9. PROVIDE ALL REQUIRED PULL BOXES AND HARDWARE FOR ALL CONDUIT RUNS. 10. ANY DEFECTIVE WORK AND DAMAGE RESULTING THE WORK SHALL BE 10. PERFORM ALL DEMOLITION WORK IN ACCORDANCE WITH THE RECULA11ONS CAPACITY. ADDITIONAL COSTS TO THE OWNER. ALL CONDUIT RUNS SHALL BE PROPERLY SUPPORTED. REPAIRED AND/OR REPLACED AS REQUIRED AT NO COST TO THE OWNER BY OF ANSI/NFPA 241-2013 BUILDING CONSTRUCTION AND DEMOLITION 6. All BUILDING MATERIALS STORED AT THE CONSTRUCTION AREA, AND/OR IN 10. THE PLUMBING CONTRACTOR SHALL PERFORM ALL CUTTING, EXCAVATION, 10. ALL EQUIPMENT SHALL BE NEW UNLESS OTHERWISE NOTED. THE CONTRACTOR. OPERATIONS. THE AREA OF THE BUILDING, SHALL BE SECURED IN A LOCKED AREA. BACKFILLING, ETC. AS REQUIRED FOR THE INSTALLATION OF THE WORK ANDSHALL PERFORM ALL FINAL PATCHING BACK TO ORIGINAL STATE, UNLESS 11. BALANCE PANEL BOARDS EQUALLY OVER ALL PHASES. CONSULTANT: 11. ALL WORK IS TO BE PLUMB, LEVEL AND TRUE. 11. PROVIDE ALL TEMPORARY BARRICADES, RAILING, LIGHTING, ETC. REQUIRED ACCESS TO SUCH AREAS SHALL BE CONTROLLED BY THE CONTRACTOR AND 12. ALL EQUIPMENT INSTALLED INDOORS SHALL HAVE A NEMA 1 RATING AND ALL 12. ALL WORK SHALL BE EXECUTED IN SUCH A MANNER AS TO PROTECT THE TO PROTECT THE WORKMEN, OWNER PERSONNEL, AND OTHERS FROM INJURY OWNER. NO HAZARDOUS MATERIAL SHALL BE STORED ON SITE WITHOUT OTHERWISE NOTED. EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3 RATING. SAFETY OF WORKMEN AND THE PUBLIC DURING CONSTRUCTION. ALL DUE TO THE DEMOLITION WORK. PROVIDE FREE AND SAFE PASSAGE OF AUTHORIZATION OF THE OWNER AND IN ACCORDANCE WITH VILLAGE 11. THE PLUMBING CONTRACTOR SHALL PERFORM ALL TESTS REQUIRED BY THE 13. PROVIDE LIQUID-TIGHT FLEXIBLE CONDUIT CONNECTIONS FOR ALL EQUIPMENT BARRIERS AND OTHER PRECAUTIONARY MEASURES SHALL BE ERECTED IN PERSONS TO AND FROM AREAS AND FACILITIES WHICH ARE TO REMAIN. REQUIREMENTS. LOCAL AUTHORITIES HAVING JURISDICTION AND ARRANGE FOR ALL INSPECTIONS SUBJECT TO VIBRATION. ACCORDANCE WITH THE AUTHORITIES HAVING JURISDICTION OR AS REQUIRED 12. PERFORM THE DEMOLITION WORK IN SUCH A MANNER AS TO PREVENT FIRES. 7• THE CONTRACTOR SHALL KEEP ALL FLAMMABLE MATERIALS TIGHTLY SEALED AS REQUIRED AT NO ADDITIONAL COST. 14. ALL PANEL BOARDS AND ELECTRICAL DISTRIBUTION EQUIPMENT SUPPLIED FOR SAFETY DURING THE ENTIRE CONSTRUCTION OPERATION. REMOVE ALL ACCUMULATED DEBRIS PROMPTLY. DISPOSAL BY BURNING WILL IN THE MANUFACTURES' CONTAINERS WHEN NOT IN USE. SUCH MATERIALS 12. ALL NEW CONNECTIONS TO NEW AND/OR EXISTING EQUIPMENT SHALL BE UNDER THIS CONTRACT SHALL BE PROVIDED WITH PHENOLIC NAMEPLATES 13. THE CONTRACTOR SHALL USE ADEQUATE NUMBERS OF SKILLED WORKMEN WHO NOT BE PERMITTED ON SITE. ALL DEBRIS SHALL BE DISPOSED OF IN A LEGAL ARE TO BE KEPT AWAY FROM HEAT. PERFORMED IN ACCORDANCE WITH THE CODE AND THE EQUIPMENT INDICATING THE PANEL NAME. ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS WORKMANLIKE MANNER. DO NOT BURY MATERIALS ON SITE. 8. ALL FLAMMABLE MATERIALS SHALL BE USED IN AN ADEQUATELY VENTILATED MANUFACTURERS RECOMMENDATIONS. 15. THE ELECTRICAL CONTRACTOR AT HIS/HER DISCRETION MAY COMBINE HOME AND WHO ARE COMPLETELY FAMILIAR WITH THE REQUIREMENTS AND METHODS 13. ALL SALVAGEABLE MATERIALS AND EQUIPMENT, INCLUDING PLUMBING FIXTURES, 13. THE CONTRACTOR SHALL PROVIDE DEMONSTRATION AND TRAINING TO THE SPACE. RUNS. > OWNER FOR ALL EQUIPMENT AND SYSTEMS INSTALLED; PROVIDE A REPORT OF NEEDED FOR PROPER PERFORMANCE OF THE WORK NOTED ON THE PLANS. FURNISHINGS, AND DECOR ITEMS SHALL BE STORED AND PROTECTED FROM 9. ALL ELECTRICAL POWER SHALL BE SHUT OFF WHERE THERE IS EXPOSED 16. THE ROUTING OF CONDUITS AND LOCATIONS OF PANELS SHOWN ON THE PLANS CONSULTANT: 14. THE CONTRACTOR SHALL COORDINATE HIS ACTIVITIES WITH THE OWNER AND DAMAGE UNTIL THE OWNER DETERMINES THE COURSE OF AC11ON TO BE TAKEN CONDUIT. ALL OPERATING PARAMETERS ALONG WITH A MAINTENANCE SCHEDULE PER THE IS DIAGRAMMATIC ONLY AND SUBJECT TO SUCH MODIFICATIONS- WITHOUT ARCHITECT/ENGINEER DURING CONSTRUCTION. 14. NOTIFY AFFECTED UTILITY COMPANIES BEFORE STARTING WORK AND COMPLY 10. ALL FIRE RETARDANT TREATED WOOD SHALL COMPLY WITH NEW YORK STALE MANUFACTURER RECOMMENDATIONS. EXTRA COST TO THE OWNER- AS EXISTING CONDITIONS NECESSITATE. WITH THEIR REQUIREMENTS. BUILDING CODE SECTION 2303.2. 14. ALL SANITARY AND STORM PIPING INSTALLED ABOVE GROUND SHALL BE CAST 15. DO NOT DISABLE OR DISRUPT BUILDING FIRE SAFETY SYSTEMS WITHOUT PRIOR 11. ALL ELECTRICAL POWER ON THE CONSTRUCTION SITE SHALL BE SHUT OFF IRON WITH "NO-HUB" JOINTS OR GALVANIZED WITH DRAINAGE PATTERN REFLECTED CEILING NOTES WRITTEN N0110E TO OWNER. AFTER WORKING HOURS. FITTINGS FOR SANITARY AND STORM WASTE PIPING AND MALLEABLE FITTINGS 16. PROVIDE DUST-TIGHT PARTITIONS BETWEEN AREAS WHERE DEMOLITION WORK IS 12. THE CONTRACTOR SHALL REGULARLY VERIFY THAT THERE IS NO LEAKAGE OF FOR VENT LINES. GENERAL LIGHTING NOTES 1. EACH PRIME CONTRACTOR SHALL COORDINATE REFLECTED CEILING PLAN WITH BEING PERFORMED AND AREAS WHICH ARE FINISHED OR IN USE. NATURAL GAS IN THE BUILDING, OR ANY FLAMMABLE GAS USED IN 15. ALL COLD AND HOT WATER LINES SHALL BE "L" COPPER TUBING WITH CAST ELECTRICAL, MECHANICAL,. AND SPRINKLER DRAWINGS FOR OTHER WORK AND 17• CONFORM TO PROCEDURES APPLICABLE WHEN DISCOVERING HAZARDOUS OR CONSTRUCTION. BRASS OR WROUGHT COPPER FITTINGS AND SOLDER JOINTS AS PER THE 1. PROVIDE LIGHT FIXTURES AS SPECIFIED, IN LOCATIONS SHOWN, INSTALLED PER APPURTENANT INSTALLATIONS WHICH MAY EFFECT THE CEILING WORK. CONTAMINATED MATERIALS, 13. CONTRACTOR HAS TO MAINTAIN ACCESS AND EMERGENCY EXITS OF THE PLUMBING CODE. MANUFACTURE'S INSTRUCTIONS AND THE NEC. 2. SUBMIT SHOP DRAWINGS OF ALL LIGHT FIXTURES FOR APPROVAL 18. CONDUCT DEMOL11ION TO MINIMIZE INTERFERENCE WITH ADJACENT BUILDING AND AVAILABILITY OF ALL UTILITIES WITHOUT ANY DISRUPTION FOR 16. ALL COLD AND HOT WATER PIPING AND FITTINGS SHALL BE COVERED WITH A PROJECT: OCCUPANCIES. OCCUPANTS THROUGHOUT THE CONSTRUCTION PHASE. MINIMUM COVERING OF 1" MOLDED FIBERGLASS PIPE INSULATION WITH A 2• FULLY COORDINATE ALL LIGHTING FIXTURE LOCATIONS WITH ALL OTHER CEILING 3. THE EXACT LOCATION OF FIXTURES MAY BE MODIFIED IN FIELD AS REQUIRED 19. CEASE OPERATIONS IMMEDIATELY IF STRUCTURE APPEARS TO BE IN DANGER. 14. THE CONTRACTOR SHALL NOT DISTURB ASBESTOS OR ANY MATERIAL MAXIMUM "K" FACTOR OF .24 AT A TEMPERATURE OF 75 DEGREES F. MOUNTED DEVICES, WITH ALL OTHER TRADES AND WITH THE OWNER. TOWN OF SOUTHOLD AND AS DIRECTED BY ARCHITECT. 3. LIGHTING TO BE MOUNTED AND CONNECTED TO BOTTOM CHORD OF TRUSS. 4. CEILING ARCHITECTURE IS ACCESSIBLE. NOTIFY ARCHITECT/ENGINEER. DO NOT RESUME OPERATIONS UNTIL DIRECTED. SUSPECTED ON CONTAINING ASBESTOS. FOLLOW THE ABATEMENT FITTINGS, VALVES AND VALVE ASSEMBLY COMPONENTS SHALL BE INSULATED FOLLOW MANUFACTURER INSTRUCTIONS. RECREATION CENTER 20. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. PROTECT EXISTING PROCEDURES REQUIRED BY THE NEW YORK STATE CODE PART 56 WITH MOLDED INSULATION WITH THE SAME THERMAL CHARACTERISTICS. 4. LIGHTING CIRCUITS ARE SHOWN FOR DESIGN INTENT ONLY. PROVIDE A NEW SUPPORTING STRUCTURAL MEMBERS. DEPARTMENT OF LABOR. 17. ALL PIPE HANGERS AND SUPPORTS SHALL BE AS PER THE CODES OF NEW DEDICATED CIRCUIT WIRING BACK TO NEAREST SUB PANEL. SUFFOLK COUNTY, NY 21. PATCH ALL EXISTING FINISHES TO REMAIN THAT ARE AFFECTED BY ADJACENT YORK STATE. 5. PRIOR TO ORDERING LIGHT FIXTURES, COORDINATE REQUIREMENTS WITH THE DEMOLITION WORK NOT SPECIFICALLY INDICATED ON THE DRAWINGS. PATCHED 18. ALL NEW PLUMBING FIXTURES SHALL BE INSTALLED WITH ANGLE STOP VALVES OWNERS REPRESENTATIVE AND THE CONTRACT DOCUMENTS, IF DISCREPANCIES WORK SHALL BE FINISHED AND ALIGN WTH EXISTING ADJACENT SURFACES. IN THE SUPPLY LINES BELOW THE FIXTURES. EXIST THE OBTAIN CLARIFICATION BEFORE PROCEEDING. BATHROOM 22. PROVIDE DEMOLITION WORK AND PROTECT THE BUILDING FROM WATER AND ACCESSIBILITY NOTES 19• ALL NEW FIXTURE SUPPLY PIPING AND WASTE PIPING SHALL BE CHROME 6. PROVIDE LIGHTING CONTROL WITH VARIABLE TIMED VACANCY SENSORS AT LIGHT GAUGE METAL FRAMING 23. WEATHER PENETRATION DURING ROOF TIE-INS AND ROOF FLASHING WORK. PLATED AND SHALL HAVE CHROME PLATED ESCUTCHEONS INSTALLED AT THE SWITCH LEVEL (AUTOMATIC ON/ AUTOMATIC OFF), UNLESS OTHERWISE ALL DEBRIS AND ADDITIONAL MATERIAL (DEEMED BY OWNER) SHALL BE 1. ALL DIMENSIONAL ACCESSIBLE CRITERIA TOILET DRAWINGS ARE BASED ON ICC PENETRATIONS THROUGH THE WALLS. INDICATED BY THE OWNER. RENOVATIONS REMOVED FROM THE SITE AND DISPOSED OF PROPERLY. A117.1-2009. 20. ALL NEW VALVES SHALL BE "FAIRBANKS" OR EQUAL RATED AT 125 PSIG, WOG, 7• TEST OCCUPANT SENSOR CONTROL' -VERIFY THAT LIGHTING TURNS OFF 1. ALL WORK TO BE DONE IN ACCODANCE NTH THE 2020 NYS BUILDING CODE. 24. ANY ITEM REMOVED FROM THE SPACE SHALL BE TURNED OVER TO THE OWNER 2. IN NEW CONSTRUCTION, ALL PUBLIC AND COMMON USE TOILET ROOMS ARE OR APPROVED EQUAL WITH-IN THE REQUIRED TIME.- VERIFY THAT LIGHTS TURN ON TO THE 2. ALL LIGHT GAUGE METAL FRAMING MEMBERS SHALL BE BY MARINO WARE OR IN UNDAMAGED CONDITION TO THE OWNER IF REQUESTED. GENERALLY REQUIRED TO BE ACCESSIBLE. 21. ANY HOSE BIB SHALL BE FROST-PROOF TYPE AND SUPPLIED WITH VACUUM PERMITTED LEVEL WHEN AN OCCUPANT ENTERS THE SPACE.- VERIFY THAT APPROVED EQUAL. INSTALL FRAMING IN ACCORDAACE WITH THE 3. THE ACCESSIBLE ROOMS MUST BE IDENTIFIED BY SIGNS. BREAKERS, WALL HYDRANTS SHALL BE KEY OPERATED, FROST PROOF AND LIGHTS ARE NOT INCORRECTLY TURNED ON BY MOVEMENT IN ADJACENT AREAS MAUNUFACTURER'S STANDARD DETAILS AND SPECIFICATIONS AS WELL AS THE 4. IN ACCESSIBLE TOILET AND BATHING ROOMS, AT LEAST ONE OF EACH TYPE OF SUPPLIED WITH VACUUM BREAKERS, SIMILAR TO J.R. SMITH. AND OR BY HVAC OPERATION. STEEL STUD MANUFACTURERS ASSOCIATION DETAILS (WWW.SSMA.COM) FIXTURE AND ACCESSORY PROVIDED MUST BE ACCESSIBLE. 22. PIPE SLEEVES SHALL BE INSTALLED AT ALL PENETRATIONS THROUGH WALLS 3. PROVIDE HORIZONTAL BRIDGING AT 4 FT ON CENTER VERTICALLY IN ALL NOISE CONTROL 5. A WHEELCHAIR TURNING SPACE IS REQUIRED WITHIN ACCESSIBLE TOILET AND AND FLOORS. 970 PECONIC LANE FRAMED WALLS. BATHING ROOMS. 23. WATER HAMMER ELIMINATORS SHALL BE INSTALLED ON ALL DROPS IN THE GENERAL POWER NOTES PECONIC, N.Y. 11958 DOORS ARE NOT PERMITTED TO SWING INTO THE REQUIRED CLEAR FLOOR WATER LINES SERVING THE TOILET ROOMS AND OTHER AREAS. 4. PROVIDE TWO 6J16 HEADERS OVER ALL OPENINGS UNLESS OTHERWISE NOTED. 1. CONSTRUCTION OPERATIONS SHALL BE CONFINED TO NORMAL WORKING HOURS: 6. SPACE AT ANY FIXTURE EXCEPT IN SINGLE-USER ROOMS WHERE A CLEAR 24. BALL VALVES FOR WATER SYSTEM SHALL BE BRONZE BODY WITH CHROME 5. ALL MEMBERS TO BE 20 GAGE MINIMUM. 7:30 A.M. TO 3:30 P.M. (AND AS PER LOCAL JURISDICTION) MONDAYS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE 6. PROVIDE FULL HEIGHT 2X4 REINFORCING AT DOOR JAMBS. FLOOR SPACE IS PROVIDED BEYOND THE SWING OF THE DOOR. PLATED BRONZE BALL, STAINLESS STEEL HANDLE, DURAFILL SEATS AND SEALS ' THROUGH FRIDAYS, EXCEPT NO WORK SHALL BE PERFORMED ON LEGAL UTILITY STANDARDS TOWN AND 2020 N.Y.S. CODES. 7. PROVIDE BACKER PLATE AT ALL TOILET ROOM ACCESSORIES AND PLUMBING HOLIDAYS. THE CONTRACTOR SHALL OBTAIN THE WRITTEN CONSENT FROM THE 7• FOR ACCESSIBLE ROUTE, SEE ICCA117.1-2009. RATED PSIG WOG.25. FLOOR DRAINS SHALL INCLUDE TRAP PRIMERS. 2. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ISSUES/REVISIONS FIXTURES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. OWNER TO PERFORM WORK AT TIMES OTHER THAN THE HOURS STATED ABOVE UNINTERRUPTED TEMPORARY POWER TO ALL TRADES DURING CONSTRUCTION. description No. Date PLUMBING FIXTURES INSTALLATION SHALL INCLUDE CARRIERS AND CLIPS AS 8. BRACE TOP OF WALL 0 EXISTING ROOF STRUCTURE AS INDICATED. AND THE WORK SHALL COMPLY WITH REQUIREMENTS FOR NOISE CONTROL AS 26. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN TEMPORARY POWER DURING . STIPULATED IN SECTION 12.07 OF NEW YORK STATE CODE. H M DOOR NOTES PER MANUFACTURER INSTRUCTIONS. THE CONTRACTOR SHALL VERIFY EXISTING WALLS FOR VERTICAL PLUMB, FLATNESS AND STRENGTH TO INSURE PROPER CONSTRUCTION AND REMOVE ALL TEMPORARY POWER AT THE END OF THE 2. THE CONTRACTOR SHALL USE ALL AVAILABLE MEANS TO MINIMIZE CONTRACT. FIT, POSITIONING AND CLEARANCES. CONSTRUCTION NOISE ON WEEKENDS BETWEEN 7:30 A.M. AND 3:30 P.M. 1. ALL DOOR FRAMES SHOWN NEAR INSIDE CORNERS OF WALL SHALL BE LOCATED 3. THE CONTRACTOR SHALL NOT INTERRUPT THE OWNERS POWER. NYS BUILDING CODE NOTES 3. IF APPROVAL IS GIVEN BY THE OWNER TO WORK ON A HOLIDAY, THE A DISTANCE OF 4" FROM THE THROAT RETURN TO THE CLOSEST ADJACENT 4. THE EXACT LOCATIONS OF THE OUTLETS AND SWITCHES SHALL BE CONTRACTOR WILL BE RESPONSIBLE TO REIMBURSE THE OWNER FOR THE COST PERPENDICULAR PARTITION, UNLESS OTHER WISE NOTED TO ACCOMMODATE COORDINATED WITH THE OWNER PRIOR TO INSTALLATION. OF OVERTIME TO HAVE AN OWNERS REPRESENTATIVE ON SITE. ADA MANEUVERING CLEARANCES. 5. CONFIRM AND COORDINATE FINAL ELECTRICAL REQUIREMENTS, 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF 2020 NEW YORK STATE 4. THE CONTRACTOR SHALL EQUIP ALL MACHINERY AND EQUIPMENT USED FOR 2. ALL WALL STOPS LOCATED IN GYPSUM WALLS SHALL HAVE METAL PLATE OR PAINTING � CONNECTIONS,AND LOCATIONS WITH ACTUAL SUPPLIED EQUIPMENT. BUILDING CODE. CONSTRUCTION WITH NOISE CONTROL DEVICES SUCH AS MUFFLERS FOR FIRE TREATED WOOD BLOCKING INSIDE THE WALL. 1- /1 I N TI N G 6. VERIFY AND CONFIRM RECEPTACLE SIZES AND LOCATIONS WITH OWNER AND A 2. BEFORE COMMENCING WORK THE CONTRACTOR SHALL PAY ALL FEES AND INTERNAL COMBUSTION ENGINES OR OTHER SUITABLE NOISE SUPRESSORS. 3. DOORS AND FRAMES SHALL BE 14 GAGE. FRAMES SHALL BE WELDED EQUIPMENT MANUFACTURER REQUIREMENTS. ALL RECEPTACLES AND OBTAIN ALL WORK AND EQUIPMENT USE PERMITS AS REQUIRED BY THE CITY, 5. NOISE PRODUCED BY CONSTRUCTION OPERATIONS SHALL BE KEPT TO A ASSEMBLY, NO KNOCK DOWN ASSEMBLIES WILL BE ACCEPTED. SWITCHES SHALL BE SURFACE MOUNTED ON EXISTING MASONRY UTILIZING THICK, 16 GAGE SPECIFIED. TOWN, STATE OR FEDERAL AGENCIES HAVING JURISDICTION OVER THE WORK. MINIMUM AND SHALL BE CONSISTENT WITH REASONABLE HUMAN HEALTH 4. DOORS SHALL BE FLUSH, BOTTOM LOUVERED, 1-3/4" 1. PROVIDE PAINT FINISH SYSTEMS WHEREVER PAINT IS INDICATED, SCHEDULES OR NON METALLIC RIGID CONDUIT AND NONMETALLIC SURFACE MOUNTED BOXES. 3. COMMENCEMENT OF OPERATIONS: NOTIFY IN ADVANCE THE VILLAGE OF REQUIREMENTS CONSIDERING TIME OF DAY AND LOCATION OF WORK SITE. MINIMUM, EXTRA HEAVY DUTY SEAMLESS CONSTRUCTION PER STEEL DOOR 2• ALL GYPSUM BOARD TO BE PAINTED. ALL EXISTING MASONRY TO BE PAINTED. 7• THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT THERE IS SUFFICIENT GARDEN CITY APPOINTED REPRESENTATIVE BEFORE COMMENCING THE WORK. 6. CONTRACTOR SHALL COMPLY WITH APPLICABLE NEW YORK STATE NOISE INSTITUTE (SDI 108-2018). ROOF TRUSSES TO BE PAINTED. ROOF DECK T BE PAINTED. ALL EXPOSED POWER AVAILABLE FOR ALL ELECTRICAL EQUIPMENT. 4. CONCEALED SPACES WITH PARTITIONS, WALL, FLOORS, ROOFS, STAIRS, FURRING POLLUTION CONTROL REGULATIONS. 5. UNDERCUT DOOR 3/4". PIPING TO BE PAINTED. ALL EXPOSED SPRINKLER PIPING TO BE PAINTED PER 8. PRIOR TO PRICING, ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL PIPE SPACES, COLUMN ENCLOSURES, ETC. SHALL BE FIRE STOPPED WITH 6. COORDINATE HARDWARE WITH OWNERS REQUIREMENTS AND ACCESSIBILITY NFPA REQUIREMENTS ITEMS, AND EQUIPMENT SHOWN ON THE DRAWING AND INCLUDE ITEMS AND NON-COMBUSTIBLE MATERIAL THAT CAN BE SHAPED, FITTED AND EQUIPMENT SHOWN ON THE DRAWING AND INCLUDE IN HIS/HER PRICING DUST CONTROL STANDARDS. HARDWARE SET TO INCLUDE 3 HINGES; MORTISE LEVER LOCI'SET 3. PAINT FINISH SHALL EXTEND FULLY TO ADJOINING NON-PAINTED SURFACES PERMANENTLY SECURED IN POSITION AS PER CHAPTER 7 OF THE NEW YORK ANY LABOR OR MATERIALS REQUIRED FOR A COMPLETE OPERATIONAL CLOSER, SILENCERS AND WALL STOP. AND MASKED WITH TAPE, SUCH AS WOOD OR ACOUSTICAL CEILINGS OR STATE CODE. SUBMIT U.L. DETAIL FOR APPROVAL. 7. PROVIDE HARDWARE COMPONENTS AS LISTED BELOW. ALTERNATE TO SPECIFIED EXISTING FINISHES TO REMAIN. SYSTEM AS PER MANUFACTURER REQUIREMENTS AND APPLICABLE CODES. 5. DUCTS, PIPES AND CONDUITS PASSING THROUGH FIRE RATED CONSTRUCTION 1. THE CONTRACTOR SHALL CONDUCT OPERATIONS AND MAINTAIN THE PROJECT ITEM WILL BE ACCEPTABLE PENDING REVIEW AND APPROVAL BY ARCHITECT. 4. SUBMIT AT LEAST THREE SAMPLES OF EACH PAINT COLOR ON MEDIUM SHALL HAVE SURROUNDING SPACES NOT EXCEEDING (1/2") IN WIDTH PACKED SITE SO AS TO MINIMIZE THE CREATION AND DISPERSION OF DUST. DUST 7.1. BUTT HINGES TOTAL USE STANLEY #FBB199 BALL BEARING FULL MORTISE; SHOWING THE ACTUAL COLOR AND CHEEN OF PAINT. SUBMIT MANUFACTURER'S WITH FIRE STOPPING MATERIAL APPROVED BY THE CODE AND CLOSED OFF CONTROL SHALL BE USED THROUGHOUT THE WORK AT THE SITE. OR EQUAL BY HAGER OR MCKINNEY. STAINLESS STEEL SATIN FINISH, LITERATURE AND SPECIFICATIONS FOR EACH PAINT SYSTEM SPECIFIED. FIRE DETECTION /ALARM NOTES WITH CLOSE FITTING METAL CLOSURES. DUCTWORK PENETRATIONS SHALL BE 2. THE CONTRACTOR MUST PROVIDE CLEAN WATER, FREE FROM SALT, OIL AND 7.2. LOCK SETS STANDARD MATCH EXISTING HARDWARE BRAND HARDWARE 5. WHERE MANUFACTURER OTHER THAN ONE SCHEDULED. PROVIDE THE PAINT PROTECTED BY RATED SELF CLOSING DEVICES PER 2020 NYS BUILDING CODE OTHER DELETERIOUS MATERIAL TO BE USED FOR ON-SITE DUST CONTROL. SHALL BE LEVER HANDLES TO MEET ADA. CONFIRM LOCKING MANUFACTURER'S EQUAL FOR APPROVAL. 1. FIRE ALARM SYSTEM NOT TO BE EFFECTED DURING CONSTRUCTION CHAPTER 7 AT ALL PENETRATIONS. SUBMIT U.L. DETAIL FOR APPROVAL. 3. THE CONTRACTOR SHALL SUPPLY WATER SPRAYING EQUIPMENT CAPABLE OF REQUIREMENTS WITH OWNER. 6. EXAMINE SURFACES TO BE PAINTED AND REPORT ANY CONDITIONS THAT 6. THE MINIMUM FIRE RESISTANCE RATINGS (2 -HOURS) SHALL BE PROVIDED FOR ACCESSING ALL WORK AREAS. 7.3. CLOSERS USE LCN 4010 SERIES FOR PUSH SIDE MOUNTING OR APPROVED WOULD ADVERSELY AFFECT THE APPEARANCE OR PERFORMANCE OF THE CONSTRUCTION ELEMENTS OR AS REQUIRED FOR THE CONSTRUCTION CLASS, 4. THE CONTRACTOR SHALL IMPLEMENT STRICT DUST CONTROL MEASURES. EQUAL. PAINTING SYSTEMS AND WHICH CANNOT BE PUT INTO AN ACCEPTABLE AND AS INDICATED ON THE CERTIFICATE OF OCCUPANCY OR APPROVED 5. DURING ACTIVE CONSTRUCTION PERIODS ON-SITE, THESE CONTROL MEASURES 7.4. WALL BUMPER USE IVES WS402CCV OR APPROVED EQUAL. CONDITION BY SPECIFIED SURFACE PREPARATION. PAINT APPLICATOR SHALL BUILDING PERMIT APPLICATION. WILL GENERALLY CONSIST OF WATER APPLICATIONS THAT SHALL BE APPLIED A 7.5. MECHANICALLY FASTENED SILENCERS (3 PAIR PER SINGLE DOOR). NOTIFY THE CONTRACTOR OF ANY REMEDIAL WORK REQUIRED TO THE MINIMUM OF ONCE PER DAY DURING DRY WEATHER OR OFTEN AS REQUIRED TO 8• CONTRACTOR SHALL SUBMIT CATALOG CUTS FOR EACH ITEM. SUBSTRATE. PREVENT DUST EMISSIONS. 9. MOUNT HARDWARE IN ACCORDANCE WITH THE DOOR AND HARDWARE INSTITUTE 7. PRIOR TO ALL SURFACE PREPARATION AND APPLICATION OPERATIONS, RECOMMENDED LOCATIONS FOR BUILDERS HARDWARE FOR STANDARD STEEL COMPLETELY MASK, REMOVE OR OTHERWISE PROTECT GLASS, FACTORY DOORS AND FRAMES, UNLESS OTHERWISE NOTED. FINISHED SURFACES, WOODWORK, PLUMBING FIXTURES, LIGHT FIXTURES, AND SHOP PRIME EXPOSED SURFACES OF FRAME AND DOOR SURFACES, INCLUDING SIMILAR ITEMS NOT SCHEDULED TO RECEIVE PAINT FINISH. GALVANIZED SURFACES USING MANUFACTURER'S STANDARD BAKED ON RUST 8. ALL SURFACES TO BE CLEAN, DRY AND ADEQUATELY PROTECTED FROM INHIBITIVE PRIMER. DAMPNESS PRIOR TO COATING. 9. STRICTLY FOLLOW THE MANUFACTURER'S GUIDE SPECIFICATIONS FOR STORAGE, D, HANDLING AND APPLICATION TO MAINTAIN SATISFACTORY WORK. 10. APPLY PAINT FINISH IN ACCORDANCE WITH MANUFACTURE'S INSTRUCTIONS AND COVERAGE RATE. z 11. APPLIED PAINT FINISH SHALL MATCH APPROVED SAMPLES AND SHALL BE FREE % OF RUNS, SAGS, AND EXCESSIVE IRREGULARITY/UNEVENNESS OF PATTERN COAT. TRANSITIONS BETWEEN COLORS AND TERMINATIONS AT ADJOINING MATERIALS SHALL BE SHARP, CLEAN AND WITHOUT OVERLAPS. / 12. FOLLOWING APPLICATION, REMOVE ANY PAINT SPATTERS FROM ADJOINING °v SURFACES. REPAIR ANY DAMAGED OR IMPERFECT AREAS OF EACH PAINT DRAWING TITLE: o FINISH IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. E Q GENERAL NOTES - 1 41 0 - E ` c° " SEAL & SIGNATURE: Design By: JG � `, Drawn By: JG/JR I +, / 4` �,,,. / Scale: AS NOTED G� �� Approved By: JG N o ��¢N ,Qh -O. Date: MARCH 2O22 o a File No: 21193.000 �, 4 Sheet No. PLOT SIZE: 24" X 36" ARCHITECT: L. K. McLEAN ASSOCIATES, P.C. r-�__ *'48" I " $��-I CONSULTING ENGINEERS 437 SOUTH COUNTRY RD., BROOKHAVEN, NEW YORK 11719 _ -�. _.>f 113d�''�1 r 48" x ,_ _�� L I 60" = 1-�-j' `I �I I I CqR = d- i=� I- IL1_ j ; I FRONT APPROi CH ' i SIDE APP CH I I 1 DIAMETER I 30"�48 ( I I 3 48 i IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE l 60" T TURN MIN. 1 1 1 Y WAY ANY LC� -J 60"x59" 60"X59" LR FLR� DEMCONN THTION OESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AF A LICENSED ARCHITECT ENGINEER,TO ALTER IN N A CHITECT/ I 1 " M N 24" MIN � 1 I CUR FLR / CLR FLR ENGINEER IS ALTERED, THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO — l j HISMER ITEM THEIR SEAL AND THE NOTATION `ALTERED BY" FOLLOWED BY HISMER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC �f' ( DESCRIPTION OF THE ALTERATION ON THE DRAWING. ' THE PLANS AND /® 1 48" X 48" 1 I `\ /O O SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A L 1 LJ FRONT APPROACH UU RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. X 60" I I _ _ McLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE I FRONT APPROACHI / I 13 r _ / SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY \ 1 C 4 ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC 60" i ' 1 - - - � J I �" o ( I o © L.K. McLEAN ASSOCIATES, P.C. 1 ® , MIN.METER i 1 48" X 48" 1 —— -I 48' X 48" li \ —— L_ ' 1 FRONT APPROACHI ; I RR FRONT APPROACH I —_ �_ i — CONSULTANT: C 1 C� 11 " 30"X4 " 30"XI8" 30"X48" " 2 MI ( 1 M �' 1 I I( 60 T TURN CLR flR CLR fLR ILR RR 3p 48 /F1 S SIG � - -rz 24" MIN 24" MIN _ c5 — I� I I � 5 X 60" I 1 54" X 60" —' 8" IMI 1'8" (MI / CONSULTANT: o SIDE APPROACH 1 1 SIDE APPROAC o o i' - = -- -- - / ./ / / �Sc4a R APPROACH TURNING SPACE FIXTURE APPROACH CONSULTANT: /4" = 1'-0" 2 SCALE: 1/4" = 1�-0"(D 3 SCALE: 42" MIN 12" MAX 16-18" PROJECT: 36" MAX 36"* 24"* 12" " " 39"-41" 2-s 1 -6 6" , TOWN OF SOUTHOLD IN. MIN. RECREATION CENTER CLEAR SUFFOLK COUNTY, NY FLOOR " " x<=24" _ = 17 -25 0 r °° SPACE Z z I I 30"X48" '" = 7"-9" _ _ �' CLR FLR Z o BATHROOM e = -Q- CD I 1 �, M _ M b L ----- RENOVATIONS M CV = Z to o, 19" MAX 48" EXIST. BLDG 13.5" Yv 12" MAX 8" MIN 6" MAX 52" NEW BLDG MIN 54" MIN 11" MIN FRONT VIEW SIDE VIEW CLEAR FLOOR SPACE AT URINALS 970 PECONIC LANE PECONIC, N.Y. 11958 56" MIN (WALL MOUNTED 17"-25" 59 MIN FLOOR MOUNTED SIDE WALLS REAR WALL OF STANDARD STALLS CLEAR FLOOR SPACE AT TOILETS KNEE CLEARANCES CLEAR FLOOR SPACE AT ISSUES/REVISIONS * WHERE SPACE PERMITS LAVATORIES AND SINKS Description No. Date CODE SUMMARY HEIGHT A.F.F./LOC CODE SUMMARY HEIGHT A.F.F./LOC CODE SUMMARY HEIGHT A.F.F./LOC GRAB BARS 33" MIN./36" MAX. TO TOP RIM HEIGHT (TOP OF LAV.) 33" MIN./36" MAX. TO TOP URINAL RIM 17" MAX. A.F.F. TOILET LOCATION 16" MIN./18" MAX. TO CENTERLINE HEIGHT OF KNEE SPACE 27" MIN. AT FRONT APRON/27" MIN. AT 8" IN FROM FRONT CONTROLS 44" MAX. A.F.F. TOILET/SEAT 17" MIN./19" MAX. FRONT LAV TO TRAP 8" MIN. HORIZONTAL CLEAR FLOOR ACCESS 30" X 48" WHERE ONE WALL/PARTITION IS LESS THAN OR TOILET FLUSH VALVE 40" MAX., 10" TO WIDE SIDE TOE SPACE UNDER TRAP 9" MIN. VERTICAL EQUAL TO 24" IN DEPTH, OR 36" X 48" WHERE BOTH SURFACE MOUNTED HEIGHT OF DISPENSER OUTLET TO BE 18" MIN. A.F.F. & 11" CONTROLS DECK MOUNT AT 34" MAX. WALLS/PARTITIONS ARE GREATER THAN 24" IN DEPTH. TOILET PAPER DISPENSER MIN. FROM BOTTOM OF GRAB BAR. OUTLET TO BE LOCATED CLEAR SPACE 30" X 48" WITHIN AN AREA 24" MIN. - 42" MAX. FROM REAR WALL. TOILET DESIGN CRITERIA LAVATORY DESIGN CRITERIA URINAL DESIGN CRITERIA u tz z o z SIGNAG " J of � w z 0 20MAX _ w SIGNAG J� J Q = J , =CIG � 4 CL CW C.) Q I— N Z AREA OF r L� cn= 2-1 C) a Z REF GE W Q Z W = W�O O N % e F- rL n N d � w U � mm ................ ........ w 45• 18" MIN. 1 � ao ...... '� ::::::. z ^ Z o w :::;;:c. 1. 0 �............. ...................------------------- LJ --. ...._.. - — ® i O = •:•:ir:tiiti• M uj L¢ z U z z3 LLJ = o N 0 o ¢ o CENTERED ON _ oa M '� o o N o cn Lu �m d o (A) 10" MAX c� co LZ z "' o o -4- � 18" MIN. > 20"-25" ( ) Z j °O x o o j 130 MIN. CLR.' HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OF GROUND LOCATION OF SIGNS AT DOORS 1 FLOOR SPACE -� FRONT VIEW DRAWING TITLE: a o _ *00 1 E TABLE 603.6 I C C /ANSI Al 17 . 1 ¢ � �r _ �r o MAXIMUM REACH DEPTH 0.5 INCH 2 INCHES 5 INCHES 6 INCHES 9 INCHES 11 INCHES z = 2009 AC CESSIBILITY 41 AAXIMUM REACH HEIGHT 48 INCHES 46 INCHES 1 42 INCHES 40 INCHES 36 INCHES 34 INCHES r, 4-1 STANDARDS L N � (B) 10" MAX > 10" - 24" (B) SEAL & SIGNATURE: Design By: JG o L NOT IN NOT IN FIGURE 308.2.1 FIGURE 308.2.2 FIGURE 308.3.1 FIGURE 308.3.2 ��F t r ��s Drawn By: JG/JR MEN WOMAN UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH �t r PICTOGRAM PICTOGRAM /jt1J G.0 G. Approved By: JG o ;'.� FIELD •� �• "•� FIELD °} n ��'� �'r Scale: AS NOTED 'N o , `� Date: MARCH 2O22 � ;r��;C�;i �, N +I File No: 21193.000 Sheet No. z NMOUNTING HEIGHTS RESTROOM SIGNS AT DOORS AND GATES REACH RANGE DESIGN CRITERIA ". ;:.. , ii -}� �` G N — 2 o � PLOT SIZE: 24" X 36" ARCHITECT: LI[Al L. K. McLEAN ASSOCIATES, P.C. CONSULTING ENGINEERS 437 SOUTH COUNTRY RD., BROOKHAVEN, NEW YORK 11719 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT ENGINEER, TO ALTER IN ANY WAY ANY ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ENGINEER IS ALTERED, THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO HIS/HER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY IS ER ! �... SPECIFIC ..:.., aim ....... :, ., D THE DATE OF SUCH ALTERATION AND A MINIM s, s,...., .,J.:..:.<... „J.. n ar ,.,,J,.,.,, �. ESCRIPTI N,a. <. , , .,, ...,, . O ON THE +, .... ,,,/i, ,.... :. DRAWING. TH L✓. E PLANS AND .. ,,,.+ rt, ,,,. ...._� //.................„ <:: SPECIFI A Ia„.....,... : C T ONS HEREIN ARE INT .�•s,.,.,,...,.� .. a 1E, ..... . ,..,,.,:, ENDED FOR THE S B ,,,,,....., � ,...,,.,, U JECT PROJECT ONLY A A ,. < ., ,..... } .,,,//,. OF CONTRA T „ .:;,.....>. C UAL NEG TIAT :� ,... �.<�.ts..,:,a„s,,. .<..,, O IONS BETWEEN THE OWN „ � t,� ,. ER AND L.K. ,s�yn £ ',t,,,,, „: ..,, if. McLEAN ASSOCIATES PC. THESE PLANJ:. rats' �,,'' SAND SPECIFI: � _ :£ l ,:r.�. CATIONS WILL BE THE i , i:£�,,,,,..,r,. + s UBJECT OF A C P R :,: - >; ,... ,:.. O Y IGHT PETIT! N O AND MAY NOT BE REVISED R t,, ,t,,,.,,, .�T( O REUSED BY / . . ,.,,,/,... .. < iANYONE c WITHOUT WRITT:.. „,....:.. t.„:.a=, EN AUTHORITY OF L.K.McLEAN;�: a., a,Is, ASSOCIATEu.PC ,i.:. .,a L{;I'r'( " #•... �C S, '":. ... �,4 :FAA� �`',�,....f�. it :: � �;,, x {f(�) L.K. McLEAN ASSOCIATES P.C. ^ i ems.. .f.:.........<.:F :., ,,..„.. FEW ,. i :, v3 �:. / �::s•,> :d"., :s�, y%//Ji '' �/;. s Yx six: CONSULTANT: i E t>;.s�.J 1:i'JssJs s%r'•:s Ni"'a• '�' ✓�� J/ p f sis I glii z / rs% / l� isf f. I€/ �n + I , a /,,.<, ,i. .III I .r "F r.:r.•�' CONSULTANT: / / fJ d : : ., _,,. ... .,� or",,;.........:,., ../ 's>i F:„:>• ';:: ..... _r /3' / /�// rl ?,saJ?,,.�.r;£%'sssf'n"//s�%� . Jib ,,,, �� ,t,� /. ,r. ,., „�,f� �'�>�:,;`F�. ,„s' i.• �// . � �t :. , i ii,; ...sir. / �• ;.. .• '.. / �/�' 3/ III %T�::<...,..A's� ... '»/. !:/:✓x�:'";s .'a,iass.• Z e' , CONSULTANT. ?a , F „ r a. PHOTO 1 PHOTO #2 PHQTO j3 PHOTO J4 PHOTO Ile PHOTO #6 PHOTO #7 PHOTO J8 PROJECT: KEY NOTES: 15 15 T 1 1RECIREATIONI CENTER REMOVE EXISTING TOILETS AND „..,,.,.„„., .�.�„-.„�.-..__.... j NY ASSOCIATED PLUMBING TYP. _...._..„.„.„... _„ 2 REMOVE EXISTING URINALS AND £ I ILA - - -i- - - - - - - -'- - - -I I- - - -i- - - - - - - -i- - - ( ->! l ASSOCIATED PLUMBING TYP. AT R M /� ; I I ; ; II II T / I I - - — — — — - - - OVE EXISTING I I iµ-...„.:+„„u,,, ,.::t,t°�c 3 REMOVE EXISTING HAND SINK AND VANITY i I ® — ® ® � ® ® ® — ® - - -�— — — — �- - - 1 r - r CONCR T FLOOR SLAB I I 1r-% E 'AT 1 0% ` 1 e% AND ASSOCIATED PLUMBING I / 4 IIF1 II I I IIF1 I I _..______ . : . ::::- ! t C� �} REMOVE EXISTING TOILET PARTITIONS TYP. g I �> I� IIj - I �..,, J L I I E OVE EXISTING Jll� IL ! Ty REMOVE EXISTING FIXED WALL, AND ASSOCIATED I I I I IPIPE VIF, TYP. cj PLUMBING. DO NOT DAMAGE STACK VENT PIPING AT 2 - - -I- - - - - - - -I- - - I I- - - -I- - - - - - - _;- ROOF PENETRATION, TYP, 7 I ,�''-�� I I 970 PECONIC LANE PECONIC, N.Y. 11958 6 REMOVE EXISTING CEI LING GRID AND TILES 4 ar ® � I JI - - —I I_ - r J I �- —— — z w-,-•„••••,••--- >64 E C - - - - � r r - - - -� L_ _ - „ EXISTING LIGHT FIXTURE TO BE REMOVED AND ASSOCIATED BRANCH I I� I I 9 IF1 II F2 I I F2 IIF1 (�=�I I f — J 3 7 I -- ! - - - - - - - - � l- I I _ M ( 8 ISSUES/REVISIONS REMOVED BACK TO SUBPANEL PP2 _ - _ -i _ -_�CIRCUIT WIRING TO BE REM f� - -�- -�- i--- �- - r-I -I �-="- 3 i I I =. I LINE F SAWCUT TYP, _ I I Description SAWCUT AND REMOVE EXISTING SLAB, ADJUST FLOOR f — �I II I I I I n -1I III No. Date 8 DRAIN AND SANITARY PIPE, V.I.F.I, I9-0 II II ® I 5 I I I - A Iu I I I o0 1 II II I 5 1I- - - -I- - - - - - - -�- -{ I- - - - - - - - - - - -I- - - 1 ° REMOVE EXISTING FLOOR TILE AND MUD SETTING BED _ .__�-..w .,.------------------__. _ L_ _ .. LI1..�.__._,..,---,.._� �,.,,„..._..... ._ „,..,._.. . _.,,......_,.„..,._ ,..., � DOWN TO EXISTING CONCRETE SLAB, VIF. EXISTING FLOOR DRAIN TO REMAIN UNDAMAGED. A £1 REMOVE EXISTING VCT FLOOR TILE DOWN TO EXISTING C/) ~ / 14 6 7 12 6 1 Q CONCRETE SLAB, PROVIDE SAW CUT LINE AGAINST --i1 � I II II OUTSIDE EDGE OF NEW WALL BOTTOM TRACK, VIF. I • I I I I 1 1 SALVAGE E=XISTING CHAIR RAIL CUT AND ALIGN WITH 14 NEW WALLS 12 REMOVE AND REPLACE EXISTING T-STAT 5 SIMILAR 5 SIMILAR EXISTING LIGHT SWITCH BACK BOX TO REMAIN; DEMOLITION PLAN' REFLECTED CEILING PLAN DEMOLITION CONCRETE FLOOR TRENCHING PLAN PHOTO LOCATION PLAN 3 EXISTING 13RANCH CIRCUIT TO REMAIN. Z 3 (:DSCALE: SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 1/4" = 1'-0" 14 REMOVE EXISTING DOOR FRAME AND HARDWARE.. 1 5 REMOVE EXISTING BASE BOARD HEATER LEGEND: REMOVE EXISTING TOILET ® REMOVE EXISTING URINAL I I REMOVE EXISTING SINK � F- a o � o I DR REMOVE EXISTING VANITY AWING TITLE: L - - -J � � N U T I O N A N D E REMOVE EXISTING 2X4 LIGHTING IRE FED.. RENCE RHTC 0 REMOVE EXISTING WALL LIGHT 41 E �- C, X I REMOVE EXISTING SUPPLY AIR DUCT S �,, �E; Design By: JG AotdD G (j Drawn B JG ,!R I I EXISTING BASE BOARD HEATER TO REMAIN. ''`"`' �" 4� Approved By: JG L............................................................ �4. Scale: AS NOTED CN , Date: MARCH 2O22 0 Q �> File No: 21193.000 Sheet No. PLOT SIZE: 24" k 36" CEILING HEIGHT CEILING HEIGHT CEILING HEIGHT CEILING HEIGHT ARCHITECT: ELEV 9'-0" ELEV 9'-0" ELEV 9'-0" ELEV 9'-0" HOLD CLEAR FROM 1 _6' WINDOW FRAME WET WALL ,,,... V.I.F. .... .... .... .... ... x. TYP. A A5 A7 -I TA q Tq N L. K. McLEAN ASSOCIATES, P.C. A CONSULTING ENGINEERS 437 SOUTH COUNTRY RD., BROOKHAVEN, NEW YORK 11719 ,- TA h ALTJ TA A4o 00 TA1 =... co... N a IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE TA .... A LICENSED ARCHITECT ENGINEER, TO ALTER IN ANY WAY ANY TA1 ""' "' W NGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ DIRECTION OF A ITEM ON THESE DRAWINGS. FIN FLOOR FIN FLOOR FlN FLOOR FlN FLOOR ENGINEER IS ALTERED, THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO HIS/HER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY ELEV 0'-0 ELEV 0'-0" ELEV 0'-0 ELEV 0-0 HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC &SCALE:E N'S INTERIOR ELEVATION E N'S INTERIOR ELEVATION MEN'S INTERIOR ELEVATION M E N'S INTERIOR ELEVATION DESCRIPTION S THE ALTERATION ON THE DRAWING. " THE PLANS AND SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. McLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE " ' " " ' " " ' " " , " SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY 1/4 = 1 -0 SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 -0 CEILING HEIGHT ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC CEILING HEIGHT CEILING HEIGHT CEILING HEIGHT CEILING HEIGHT ELEV 10'-0" V.I.F. © L.K. McLEAN ASSOCIATES, P.C. ELEV 9'-0" ELEV 9'-0" ELEV 9'-0" ELEV 9'-0" VESTIBULE CEILING HEIGHT BEYOND CONSULTANT: RAISED ACRYLIC SYMBOLS ELEV 8'-0" 1� WET WALL A TYP. TA TA N TA TA A5 A7 TA - = I TA o ® �.. . - CONSULTANT. o _ F � TA1 o ..:............... .... ..L..... ..,y.. r? ... FIN FLOOR A3 A6 TA1 ....:..... FIN FLOOR FIN FLOOR FIN FLOOR FIN FLOOR �8H ELEV 0-0 ELEV 0-0 ELEV 0'-0" ELEV 0'-0" ELEV 0'-0" W OMEN S INTERIOR ELEVATION WOM EN'S INTERIOR ELEVATION WOM EN'S INTERIOR ELEVATION WOM EN'S INTERIOR ELEVATION BATHROOM ENTRANCE ELEVATION 1/4" = 1'-0" 6 SCALE: 1/4" = 1'-0" cJ SCAL7 E: 1/4" = 1'-0" 4" SCALE: 1/4" = 1'-0" 3 SCALE: CONSULTANT: 12 1 1 12 PROJECT: s-64 9'-2d" TOWN OF SOUTHOLD 3 KEYNOTES: RECREATION CENTER _.—� � µ SUFFOLK COUNTY, NY � R ___. ! j ' � � NEW FLOOR MOUNTED ADA COMPLIANT — - — FCC - G �' I 1 TOUCHLESS TOILET TYP. - ---- i - -n_ jl .�_.. ....... .. .I.L... :.... _.... ....... /% �. 2 NEW WALL HUNG ADA COMPLIANT 1 0 -_ I� _ I I I I �- ': i TOUCHLESS URINAL TYP. BATHROOM NEW FRP TOILET PARTITIONS TYP. RENOVATIONS ................... 6 4 NEW ADA COMPLIANT TOUCHLESS _�������� INTEGRATED NAND SIN .... K rj LINE OF NEW WOOD CHAIR RAIL TO MATCH EXISTING 970 PECONIC LANE 3 �, �, 3 F1 F1 PECONIC, N.Y. 11958 a ^ ..................... NEW HUNG CEILING USE ROCKFON SQUARE LAY IN 1 / 7 __.................................. E HYGENIC PLUS MINERAL WOOL AND 15/16 WHITE I CEILING.............. -.._._._.._ LING GRID ISSUES/REVISIONS M� -^LC-Fe NEW LED CEILING LIGHT FIXTURE `n F �_ ELEV=9 -0 I ELEV=9 -0 Description No. Date N I NEW LED WALL LIGHT FIXTIRE - - D2 -- GFVCI .. ..................................................._................................_............._......................_. NEW WHITE SUPPLY CEILING REGISTER. CONNECT TO 3 — g 9 EXISTING DUCTWORK, VIF. I _ j j 9 :tzi / 1 O NEW RECESSED BABY CHANGING STATION ................. .-.............-.. --------.- I ...,., N 9 - G 8 10 EFT" _. EFD 6 4 GFCI N 1 1 NEW H.M. DOOR, FRAME AND HARDWARE 711A /7 1 NEW-4' BASE BOARD HEATER TO MATCH EXISTING. 12 USE SLANTFIN OR APPROVED EQUAL, V.I.F. I o M .................................._.I ................. ... 4 GFCI GFCI N RELOCATE EXISTING LIGHT FIXTURE �- F2 13 / 8 F2 I p 14 EXISTING FIRST AID KIT: SALVAGE AND REINSTALL i 8 r7 ................-...__..._......-........-..-.................--.. ------------ ....._.............. 3 �� _ I �� 1 ..._..-----!..............................................._.--- ----..-...... ... - ._--................ .... ... ..... ADA SIGNAGE _ 15 ;1 11 GFCI 44" 44T• PT i SIGN - - - -5 -- -- - - - SIGN - BRAILLE BRAILLE- - ' _ ! ELEV=8'-0" NEW GYPSUM PARTITION SEE WALL TYPES I ON SHEET A-2 ..... _..— :� I--------' '- -- '---- - - -----..-.-- -------- -'--'-'� -- -'--- -- --- — ----'-.... c� i y 14 C7 1 5 GYPSUM PIER 6 I F3 F3 / GYPSUM PIE EXISTING 2'X4' LIGHTING FIXTURE 7 EF1 . ..--......._..................-........._._i _._.__.-_._._._-__ _ _ ___ _ _ INSTALL NEW 2'X4' LIGHTING; H E WILLIAMS EDGE-LIT .....-..........--'--..................... ..... "-'-.-'-'-)--._._.....--'- ....�.-.-.-.- -- -�- ... E .-...- _ , / ( _ I- �. FLAT PANEL - 2 X4 LP-24-L50/835-QS-DIM-UNV 5 5 �IEF1 Ii jIEF1 Ij F1 - - - - - - I 'r- - - - - I II INSTALL NEW 6"X24" WALL LIGHTING H.E. WILLIAM ! /. / / _/� % // �� I / ........ ...............HDR=7'-�..... --- - E / I� ARCHITECTURAL WALL MOUNT LED 2' - - -- - - - -- - ---- - - - - - - L.-. ..... ..... _....... .. - - --- --- - _ F2 WMA-2-L40/835-AF-DIM-UNV J moo EF1 13 13 EF1 OF3 INSTALL NEW 4"0 RECESSED LIGHTING_ H E WILLIAMS DRAWING TITLE: v 4PR-TL L20/835-DIMI-UNV-LW-OF WH N F1 C O III S T U C T I 0 INI E 3 EXISTING FLOOR DRAIN; ADJUST TO MEET NEWISEFD 00 �� FLOOR TILE FINISHES. PLANS 2 �D PROPOSED LIGHT SWITCH WITH 41 VACANCY/OCCUPANCY SENSOR ADJUSTABLE TIMING 41 GFCI DUPLEX GFCI RECEPTACLE SEAL & SIGNATURE: Design By: JG o i . ......... _. . ._. _ DUPLEX RECEPTACLE ON NEW DEDICATED GFCI � Ut �;r�y Drawn By: JG/JR CIRCUIT BACK TO SUBPANEL IN MAIN ELECTRIC 'c°� ' �u (; Approved By: JG CLOSET �F" ��, 41 CONSTRUCTION PLAN !SC7/2 Scale: AS NOTED i�j„ �,'' y }Y0 1 � THERMOSTAT-REPLACE EXISTING WITH NEW �c� �•,.r � Date: MARCH 2O22 a o SCALE: 1/2" = 1 -0" '�`' File No: 21193.000 S 't r 7-t:;(;fs' "y� ; Sheet No. . r 04 M l.Ah,���, A - 1 L 0- PLOT SIZE: 24" X 36" ARCHITECT: / EXIST. TOILET ACCESSORIES. OF ASSEMBLY EXIST,ROOF ASEMBLY SEE INTERIOR ELEVATIONS L. K. MCLEAN ASSOCIATES, P.C. # ACCESSORY MANUF. / MODEL # FINISH REMARKS CONSULTING ENGINEERS 437 SOUTH COUNTRY RD., BROOKHAVEN, NEW YORK 11719 \ / CEILING HEIGHT V.I.F. TA1 S C DISPENSER URFACE MOUNTED BOBRICK B-4221 STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. FASTEN TOP TRACK IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE • TO EXIST CEILING DIRECTION OF A LICENSED ARCHITECT ENGINEER, TO ALTER IN ANY WAY ANY \ / 2X4 BRACING TO ROOF TA2 H.C. MIRROR BOBRICK STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ STRUCTURE 48"O.C. I I PAPER TOWEL DISPENSER ENGINEER IS ALTERED,THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO TA3 BOBRICK B-369 HISMER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY GYPSUM WALL FINISHE I i & WASTE RECEPTACLE STAINLESS STEEL RECESSED - SEE INT. ELEVS. HISMER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION ON THE DRAWING. " THE PLANS AND SPECIFICATIONS HEREIN`!ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A TA4 TOILET TISSUE HOLDER BOBRICK B-2888 STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. MCLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE » » SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY MOUNT ACCESSORY ON SHIMS AND PROVIDE I I TA5 GRAB BARS BOBRICK B-6806 STAINLESS STEEL LENGTH 30 & 1$ - SEE INT. ELEVS. ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.MCLEAN ASSOCIATES,PC BACKER ROD AND SEALANT AT ALL GAPS I ( CEILING HEIGHT LI I CEILING HEIGHT SURFACE MOUNTED SANITARY c L.K. MCLEAN ASSOCIATES, P.C. ELECTRIC J-BOX TYP. I IELEV:9'o" I ELEV:8'0" TA6 NAPKIN DISPOSAL BOBRICK B-270 STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. TOILET ROOM ACCESSORY TA7 HEAVY-DUTY CLOTHES HOOK BOBRICK B-211 NICKEL-PLATED WALL MOUNTED - MOUNT 48" ON INSIDE TOILET CONSULTANT: TOILET ROOM TOILET ROOM HIGH BAY PRIVACY VESTIBULE STALL DOORS, TYP. RECESSED BABY CHANGING WALL TILE TA8 STATION KOALA KARE KB311-SSRE STAINLESS STEEL RECESSED - SEE INT. ELEVS. STEEL BACKER PLATE AT ALL TOILET FIXTURES SEE PROPOSED FLOOR PLAN 2X6 :SUBWAY TILE TOP WALL HUNG ACCESSORIES BULL NOSE 3-5/8"MTL.STUD 20 GA. 3-5/8"MTL.STUD 18 GA. # FIXTURE MANUF. / MODEL # FINISH REMARKS CONSULTANT: 16"OC TYP, 12"OC TYP. 11-1 WALL MOUNT SINK BRADLEY VERGE - LVQ-SERIES BRUSHED STAINLESS WALL-HUNG LAVATORY; ADA COMPLIANT MOLD AND MOISTURE RESISTANT GYPSUM BOARD 1F2 TOUCHLESS SINK FAUCET BY BRADLEY SATIN STANLESS • WALL-HUNG LAVATORY; AUTOMATIC A.C. OPERATION, ADA COMPLIANT TOUCHLESS SINK FAUCET HIGH STRENGTH ACRYLIC I 15/8"MOLD AND MOISTURE I I ' 11-2A BY BRADLEY N/A BELOW SINK AC POWER SUPPLY PER 5!8"TYPE-X GYPSUM BOARD POWER SUPPLY MANUFACTURER REQUIREMENTS POLYMER TILE ADHESIVE • I I ; RESISTANT TYPE-X GYPSUM I I • BOTH SIDES;LEVEL FOUR 1F3 ACCESSORY WALL INTERFACE BOARD BOTH SIDES FINISH. SINK P-TRAP BY BRADLEY POLISHED CHROME INCLUDES CLEAN-OUT PLUG AND BRUSHED I I • • I I : STAINLESS STEEL REMOVABLE APRON CONSULTANT: 1F4 URINAL SLOAN VITREOUS CHINA WHITE WALL HUNG; REINFORCE WALL HUNG URINAL PER 8"CERAMIC SUBWAY WALL TILE I I NEW WOOD CHAIR RAIL TO WASHDOWN URINAL SU-1009 MANUFACTURE INSTRUCTIONS. I I I I MATCH EXISTING WHITE LATICRETE SPECTRALOCK I I I I TF5 URINAL FLUSH VALVE SLOAN ROYAL 186 ESS STAINLESS STEEL ADA COMPLIANT, AC POWER SUPPLY TOUCHESS GROUT, OR APPROVED EQUAL I I I I OPERATION WET WALL TILE TF6 URINAL STRAINER KOHLER NO--K-9183 STAINLESS STEEL BEEHIVE GRATE FOR CAULKING 2" PIPE. O TOILET BOWL KOHLER HIGHCLIFF ULTRA TOP SPUD FLUSHOMETER BOWL WHITE FLOOR MOUNTED ADA COMPLIANT „ I 2X6 WA(NSCOIT I �„ I I �» I K-96057-SS PROJECT: TOP BULL NOSE TF8 TOILET BOWL KOHLER HIGHCLIFF ULTRA TOP WHITE FLOOR MOUNTED NON-ADA COMPLIANT TOWN OF SOUTHOLD SUD I I CONTINUOUS MTL.RUNNER 6"VINYL WALL BASE, 5P96 57 SHQMETER BOWL RECREATION CENTER SECURED TO EXIST FLOOR I I TO MATCH EXISTING TFg•1 TOILET BOWL FLUSHOMETER SLOAN ROYAL 111 ESS STAINLESS STEEL ADA COMPLIANT; AC POWER SUPPLY TQUCHLESS SUFFOLK COUNTY, NY + I I I I CONTINUOUS MTL.RUNNER OPERATION SECURED TO EXIST FLOOR TFg TOILET BOWL SEAT KOHLER ELONGATED WHITE OPEN FRONT SEAT WITHOUT LID M SEALANT BOTH SIDES I I NOMKE 47131-CAAL AVY DUTY SEAT • I SEALANT BOTH SIDES BATHROOM • I I TOILET PARTITION SC RENOVATIONS EXISTING CONCRETE FLOOR EXISTING CONCRETE FLOOR / R E E N /C O M P A R TM E N TS INSIDE CORNER WALL TYPE WALL TYPE # COMPARTMENT MANUF. / MODEL # FINISH REMARKS 1 SCALE:NTS SCALE.NTS TPt TOILET PARTITION GENERAL PARTITIONS SERIES 40 FR-786, PEWTER FLOOR MOUNTED OVERHEAD BRACED, 970 PECONIC LANE FRP PARTITION I SURFACE MOUNTED PECONIC, N.Y. 11958 1P2 URINAL SCREEN GENERAL PARTITIONS SERIES 40 FR-786, PEWTER WALL MOUNTED 12 INCHES ABOVE IFRP SCREEN FNISH FLOOR, CONIIUOUS CLIP FINISH SCHEDULE ISSUES/REVISIONS 3X6 SUBWAY TILE STACK BOND; FRONT ELEVATION SIDE ELEVATION X Description No. Date 11 COURSES AT WAINSCOTT 27 COURSES AT WET WALL # ASSEMBLY MANUF. / MODEL # FINISH REMARKS 15-1/4" 15 1/4" CT-1 EXIST CONCRETE FLOOR TRAFFIC MASTER VIGO GRIS 12 INCH X 24 INCH HOME DEPOT OR APPROVED EQUAL 20" CERAMIC FLOOR TILE, ON MEDIUM SETTING BED 4X6 SANITARY TILE BASE CT-1 GYP WALL WAINSCOII DAL TILE CLASSIC COLOR WHEEL 3 INCH X 6 INCH WWW.DALTILE.COM OR APPROVED FLOOR TILE ON ' SUBWAY TILE COLOR (41); ALMOND 0135 EQUAL MEDIUM SETTING BED DAL TILE CLASSIC COLOR WHEEL 3 INCH X 6 INCH WWW.DALTILE.COM OR APPROVED CT-2 GYP WALL WET WALL SUBWAY TILE COLOR (41); ARCHITECTURAL GRAY 0109 EQUAL I PT-1 NEW/EXIST GYP WALL SHERWIN WILLIAMS OR EGG SHELL SUBMIT MANUFACTURER STANDARD TURN UP 48" 82" 5s" 48" APPROVED EQUAL COLORS FOR OWNER APPROVAL WATERPROOF MEMBRANE HM DOORS AND FRAMES; WOOD SHERWIN WILLIAMS OR SUBMIT MANUFACTURER STANDARD AT WALLS TYPICAL I 48" 47" PT-2 MILLWORK APPROVED EQUAL SEMI-GLOSS COLORS FOR OWNER APPROVAL - - - - - - - - -, 60" 71 PAINT SCHEDULE a a PT-1, NEW GYPSUM, EXISTING MASONRY WALLS AT SHOWER ROOM. _...... ----- _ -__....._ " " 12 2 PRIMER: HIGH PERFORMANCE FINISH PRIMER ProMar 200 ZERO VOC LATEX PRIMER B28W2600 STI COAT: PRO INDUSTRIAL PRE CATALYZED WATER BASED EPDXY GLOSS, B73-300 SERIES. N2 D COAT: PRO INDUSTRIAL PRE CATALYZED WATER BASED EPDXY GLOSS, B73-300 SERIES. STANDARD HARDWARE SERIES 40 - TYPICAL ELEVATION WALL HUNG URINAL SCREEN WITH CONTINUOUS FLANGE CERAMIC TILE D ETAI LSD WALL STANDARD HARDWARE BACKING POINTS FOR OTHER THAN MASONRY WALLS INDICATED PT-2, MISCELLANEOUS METALS, DOORS AND FRAMES. Z RIMER: SEMI-GLOSS FINISH PRIMER; PRO INDUSTRIAL PRO CRYL UNIVERSAL PRIMER B66-310 SERIES. STI COAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS, B66-650 SERIES. SCALI�: 3" = 1'-0» ND COAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS, B66-650 SERIES. TOILET PARTITION ELEVATIONS 1 SCALE: NTS GREY LATICRETE SPECTRALOCK GROUT, OR APPROVED EQUAL rn 12 X 24 FLOOR TILE SEE FINISH SCHEDULE N EXISTING METAL DOOR I % POLYMER MODIFIED HIGH MEDIUM BEAD PROFILE OF EXISTING FLOOR I NEW FLOOR TILE STRENGTH LARGE TILE ADHESIVE; RAISE EXISTING jUSE 4-XLT RAPID BY LATICRETE OR APPROVED EQUAL FLOOR DRAIN, VIF I FLOORTHRES OLDSTOABDE REMOVED. BEIGE MARBLE REMOVE EXISTING PENNY TILE; a DRAWING TITLE: a LIQUID RUBBER MEMBRANE; USE HYDRO BAN ELASTOMERIG SEALANT \I_ THRESHOLD AND DOOR THRESHOLD DS -663-1021 BY LATICRETE OR APPROVED EQUAL EXISTING VCT AND DETAILS AND AT GAP ELASTOMERIC SEALANT o I�I� AT GAP NEW OLD REMOVE EXISTING MUD SETTING BED LINE OF SAW CUT, EXISTING CONCRETE ON-GROUND �I r - _ _ - - mid- ^ » VIF CONCRETE ON-GROUND, SCHEDULES I� `t I� EXPOSE SURFACE AS PROPER 41 7 SUBSTRATE FOR NEW TILE — SIN U ■ a■ ®® ® ■. s e. a ear a we ■. �a ■es■ m 1 — — — — ,• .. .. — i1�.Td;. �C,7d C.7d T ifs mod., .+ .■. ® ® .. � . .. ®. s ® .. � .. e ® .. � ., .. .. ® ® ® ® ® � ® ■! s ® ® ® ® ® ® ® .. ® � �■ ® .. .. � ® ® ® .. ® .. .. �■ ® . t• •;::..::,:. SEA & GN, T6J, Design By JG L SIGN, r E: Drawn By: JG/JR DIE3 rn �' �Id- �Id- a. Q ��`�� • / SF Approved By: JG AS NOTED I Scale:0 Q Date: MARCH 2O22 0 Q Y 4 >' CERAMIC TILE DETAILS FLOOR , `,,`ri�,c� � l Sheele t No. 21193.000 SCALE: 6" = 1'-0" A ® 2 ' v mi 0- 1 PLOT SIZE: 24" X 36" ARCHITECT: L. K. McLEAN ASSOCIATES, P.C. CONSULTING ENGINEERS 437 SOUTH COUNTRY RD., BROOKHAVEN, NEW YORK 11719 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT ENGINEER, TO ALTER IN ANY WAY ANY ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ 4" VENT THROUGH ROOF, VIF ENGINEER IS ALTERED,THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO HIS/HER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY ROOF HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION ON THE DRAWING. " THE PLANS AND SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K McLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC © L.K. McLEAN ASSOCIATES, P.C. CONSULTANT: EXISTING SANITARY RISER EXISTING SANITARY VENT CONSULTANT: 2" 2" 2" 2" 1 " UR UR CONSULTANT: VERIFY WITH SPECIFICATION VERIFY WITH SPECIFICATION LAV LAV WC WC WC WC FD FD FLOOR PROJECT: p7j N N 2„ 2" 2" 4 4 4„ 4„ 2" TOWN OF SOUTHOLD 3" 3" RECREATION CENTER SUFFOLK COUNTY, NY 4" 4" BATHROOM RENOVATIONS CONNECT TO EXISTING WASTE LINE. MODIFY AS REQUIRED 970 PECONIC LANE SANITARY RISER DIAGRAM PECONIC, N.Y. 11958 1 N.T.S. ISSUES/REVISIONS Description No. Date ROOF CONNECT TO EXISTING WATER TO EXISTING PIPING AND LINES V.I.F. HOT WATER HEATER cw c cw�cw—cw�cw cw�cw—cw—c —Cw—Cw—Cw cw—cw—C —cw—cw cw—cw— „VI Cw cw 3 3 r >HW—HW—HW—@�—HW—H HW—HW'� HW HW W— W—HW— W > HW—HW-2iW HW—HW —HW—HW�Hn— —HW 1" u I I I1 VIF x I TP TP U U = U U I ( I U U U U WHA WHA ( WHA > WHA > WHA WHA I WHA I WHA I WHA I WHA `�3 " 3 > > I � U = U i U U LIST OF ABBREVIATIONS „ > u " 1n '" I N " " ° I u 1n 1N In = L I = I I I I TP = TRAP PRIMER lu u u u WC = WATER CLOSET = I I I I I OTES: SHAR = SHOWER FD = FLOOR DRAIN U U U 1. PROVIDE INSULATION AT ALL DOMESTIC HOT WATER PIPING '_ 2. PROVIDE INSULATION AND VAPOR BARRIER AT ALL COLD WATER SUPPLY UR = URINAL A PIPING HWS = HAND WASHING STATION 3. PROTECT ALL INSULATED PIPING WITH PVC JACKETING LAV = LAVATORY DF = DRINKING FOUNTAIN/BOTTLE FILLER HB = HOSE BIB 3 LAV WC UR UR LAV WC WC owc WHA = WATER HAMMER ARRESTOR FD FD 3 DOMESTIC WATER RISER DIAGRAM DRAWING TITLE: ON. P UMBNG RISER E T.S. O 0 .o DIAGRAMS E � SEAL & SI ,N9TURE: Design By: JG ` URA. Drawn By: JG/JR DIC>14 . '� Approved By: JG F Scale: AS NOTED v' f. w Date: MARCH 2O22 N p rr �' File No: 21193.000 `V Sheet No. c) :E 0- PLOT SIZE: 24" X 36" rW.TOWN OF SOUTHOLD J O < arr " 0� RE.CREATION CENTER BATHROOM RENOVATIONS R / I e1z : max .._.... •,Aa«wa r.a ra• LOCATION MAP ' aw (9 . 0 N.T.S. AREA OF WORK 335 S.F. A, AD ` PROVIDE _ RECREATION OFFICE ' TEMPORARY TO REMAIN ACTIVE; ENGINEER: " TOILETS I PROTECT OFFICE STAFF AND EXISTING I EQUIPMENT FROM CLOSET P I ( DUST AND DEBRIS ELECTRI' CONTRACTOR w « BUILDINGACCFSS I L. K. MCLEAN ASSOCIATES ` ENGINEERING & SURVEYING, D.P.C. CONTRACTOR CONSULTING ENGINEERS 437 SOUTH COUNTRY RD.,BROOKHAVEN,NEW YORK 11719 CONSTRUCTION ZONE; CORDONE . : MAXIMUM OCCUPANT COUNT = 371 OFF FROM PUBLIC PERSONS WITH TEMPORARY v,.,����^ar", ... ,�" '% •r IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE OF A LICENSEDALTER IN ANY WAY ANY MULTI FUNCTION SPACE TO REMAIN WALL TEMCTION ON THESE DRAWINGSA F AN ITEM BEARING THRCHITECT ENGINEER, E SEAL OF AN ARCHITECT/ FUNCTIONAL; PROTECT FROM DUST AND ENGINEER IS ALTERED,THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO DEBRIS. COORDINATE WITH OWNERS HIS/HER ITEM THEIR SEAL AND THE NOTATION 'ALTERED BY' FOLLOWED BY HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC SCHEDULE TO ELIMINATE PROGRAMMATIC DESCRIPTION OF THE ALTERATION ON THE DRAWING. " THE PLANS AND 970 PECONIC LANE CONFLICTS SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. MCLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.MCLEAN ASSOCIATES,PC PECONIC , N .Y. 11958 ©L.K. MCLEAN ASSOCIATES ENGINEERING &SURVEYING, D.P.C. TAX MAP NUMBER PROJECT: DISTRICT: 1000 CONTRACTOR ACCESS SECTION: 075.00 TOWN OF SOUTHOLD BLOCK: 01 .00 SUFFOLK COUNTY, NY LOT: 015.002 MINUMUM NUMBER OF REQUIRED TOILET FIXTURES SOUTHOLD BUILDING AREA = 6SF BATHROOM NYSBC TABLE 1004.5; N RECREATION CENTER 5; YSPC TABLE 403.1 OCCUPANT LOAD = STATED OCCUPANCY = 371 (USE 372) 50-50 GENDER RULE RENOVATIONS 186 MALE OCCUPANTS 186 FEMALE OCCUPANTS MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES PER TABLE 2902.1 ASSUME 372 TOTAL OCCUPANTS 50/50 GENDER COUNT 970 PECONIC LANE WATER CLOSETS (WC) LAVATORIES (LAV) DRINKING FOUNTAINS (DF) OTHER (SERVICE SINK) PECONIC, NY 11958 MALE FEMALE MALE FEMALE ISSUES/REVISIONS ASSEMBLY 186 OCCUPANTS 186 OCCUPANTS 186 OCCUPANTS 186 OCCUPANTS 1/100 = 1 DF 1 REQUIRED Description No. Date 1/125 = 2 WC 1/65 = 3 WC 1/200 = 1 LAV 1/200 = 1 LAV PECONIC LANE PERMIT RENEWAL: FINISH COLORS 1 01-10-2025 PERMIT NOTES REQUIRED 2 WC TOTAL 3 WC TOTAL 1 LAV TOTAL 1 LAV TOTAL 1 DF TOTAL EXISTING 1 SERVICE SINK TOTAL PLUMBING FIXTURES EXISTING SITE PLAN 1. FIRE ALARM SYSTEM NOT TO BE EFFECTED DURING CONSTRUCTION TOTAL 2. ALL CONSTRUCTION SHALL COMPLY WITH ICC/ANSI A117.1-2009 ACTUAL 3 WC TOTAL 3 WC TOTAL 1 LAV TOTAL 1 LAV TOTAL 1 DF TOTAL 1 SERVICE SINK TOTAL PLUMBING FIXTURES TOTAL COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES AERIAL MAP , y , , r ABBREVIATIONS CDSYMBOLS LEGEND , .ALUMN. ALUMINUM EA. EACH HT. HEIGHT P.S.F. POUNDS PER SQ. FOOT DESCRIPTION SYMBOL DESCRIPTION E.C. ELECTRIC CONTRACTOR H.W. HOT WATER RECEPTACLE �R, ® �j SYMBOL DE APPV'D APPROVED RECEPT ELEV. ELEVATION INSUL. INSULATION REQ D. REQUIRED BD. BOARD Q BOT. BOTTOM SECTION NUMBER ELECT. ELECTRIC INV. INVERT REINF. REINFORCED B.O. OTTOM OF RES. Q m EXIST. EXISTING JT. JOINT RESILIENT -; v. - ;;;. ,.;, /, j . ; , x SECTION X-X FINISH TAG ® ,;, O B/O BY OTHERS EQ. EQUAL L.P. LOW POINT RM. ROOM STATUS: r - �� '' ' �� DRAWING SHEET INDEX ; .' , �., ,, SHEET NUMBER BLDG. BUILDING EQUIP. EQUIPMENT LTG. LIGHTING SECT. SECTION w W ,r NOT FOR CONSTRUCTION 3 ;�' : ' / , , ��-�„ r../ ;, ,.:: :.�....;;, AREA OF TOILET %'/ _ ,., ,,.': BLK. BLOCK EXH. EXHAUST LAV. LAVATORY S/C SELF CLOSING N N o „/ i .' ROOM WORK / °.e 1' % ' Y" ' BLKG. BLOCKING FL. FLOOR MAX. MAXIMUM SPEC. SPECIFICATIONS O '% " . SHEET NO. SHEET DESCRIPTION DETAIL NUMBER C.T. CERAMIC TILE F.D. FLOOR DRAIN MTL. METAL STL. STEEL DRAWING TITLE: ` ' CLO. CLOSET FIN. FINISH MFG. MANUFACTURER STRUCT. STRUCTURAL / '.. ,. g.. ::� ,. X DETAIL TAG X WINDOW TAG� ,CONTRACTOR ACCESS f' "° FIXT. FIXTURE MAS. MASONRY SUSP. SUSPENDED - „< SHEET NUMBER v ;"/ COL. COLUMN MAT MATERIAL T & B TOP AND BOTTOM CLG CEILING GENERAL r .e FDN. FOUNDATION CO-1 COVER SHEET ® COVER SHEET '' ' "` '' ' CONT. CONTINUOUS FTG. FOOTING MIN. MINIMUM T & G TONGUE & GROVE ;`."y ' y n ; . , �': UN-1 GENERAL NOTES-1 • L O .; q j CONST. CONSTRUCTION ELEVATION NUMBER F/E FIRE EXTINGUISHER MECH. MECHANICAL T.O.S. TOP OF SLAB ,�;� ,� ; .� : „ . ,.:. <�/ �, ; ;. ,; .; .�; , .� C.W. COLD WATER GALV. GALVANIZED M.O. MASONRY OPENING TYP. TYPICAL GN-2 ICC/ANSI A117.1 2009 ACCESSIBILITY STANDARDS • %e / t' o , AREA OF WORK ELEVATION PARTITION TYPE x X CONC. CONCRETE G.C. GENERAL CONTRACTOR NO. NUMBER V.I.F. VERIFY IN FIELD SEAL & S URE: Design By: JG A110N TAG I fu u v� `' ' ' " ' - SHEET NUMBER C.B. CATCH BASIN GYP BD. GYPSUM BOARD N.I.C. NOT IN CONTRACT VERT. VERTICAL ARCHITECTURAL P�EOFIyE�, Drawn By: ]R / GL. GLASS O.C. ON CENTER VEST. VESTIBULE 5� Z A. y' N DBL. DOUBLE J� Approved B CFD N a� <. ', a ./ / ✓".>":; DM-1 DEMOLITION PLAN • 0�'R - S O t� Scale: AS NOTED DET DETAIL HDR HEADER OPEN OPENING V.T.R. VENT THRU ROOF * � �,, A-1 CONSIRUCITON PLAN • r+ Date: ]AN. 2025 ,,. - ,,, ; ;, x DIA. DIAMETER H.M. HOLLOW METAL P.C. PLUMBING CONTRACTOR W,p• WATERPROOF r- ,,, o ,:, � ",. � ' %, / TNT. ELEVATION NUMBER P.L. PROPERTY LINE �-, File No: 21193.000 Iy / / �:: .,; <;, gj ,,. ..;c,> /.., y/ % ,' ."' i. :c " r� 6/ gs' HVAC A-2 DETAILS AND SCHEDULES O o �;, „ i:. DN DOWN / WITH HEATING, VENTILATION o ` o / ,..�,� �, ,,, ,' , - , .'� �. .. , ����G,. .; X X Z c, I Sheet No. '•" INTERIOR ELEVATION & AIR CONDITIONING PL. LAM. PLASTIC LAMINATE / ;:.- ::.:. X DOOR TAG DWG. DRAWING W.C. WATER CLOSET MID J'PLUMBING RISER DIAGRAMS AND CEILING FAN • F 0 � SHEET NUMBER / EACH 397 WAY HD HOOD O 7 C0 1 � PL PLYWOOD WD WOOD � HORIZON. HORIZONTAL P.S.I. POUNDS PER SQ. INCH QT. QUARRY 11LE QL FULL SIZED PLOT SIZE:24"x 36" 1 GENERAL NOTES DEMOLITION NOTES SAFEGUARDS DUIPLUMBING ELECTRICAL f CONSTRUCTION PROJECT 1. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND 1. THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS AS REQUIRED IN 1. ALL PLUMBING WORK WILL BE SUBJECT TO THE TOWN OF SOUTHOLD'S 1. THE ELECTRICAL CONTRACTOR SHALL PULL A SEPARATE ELECTRICAL PERMIT. LOCATION STATE CODES. ORDER TO COMPLETELY DEMOLISH AND REMOVE ALL OF THE ITEMS NECESSARY PLUMBING INSPECTOR. 2. ALL ELECTRICAL WORK WILL BE SUBJECT TO THE TOWN OF SOUTHOLD'S 2. ALTHOUGH THESE PLANS ARE DRAWN TO SCALE, NO DIMENSIONS SHALL BE TO COMPLETE THE WORK WHETHER OR NOT IT IS SHOWN ON THE PLANS OR 1. THE PROVISIONS OF THE BUILDING CODE OF NEW YORK STATE CHAPTER 33, 2. THE PLUMBING CONTRACTOR SHALL PULL A SEPARATE PLUMBING PERMIT. ELECTRICAL INSPECTOR. SCALED. DESCRIBED IN THE SPECIFICATIONS. SAFEGUARDS DURING CONSTRUCTION, SHALL GOVERN THE CONDUCT OF ALL 3. ALL PLUMBING WORK UNDER THIS CONTRACT SHALL CONFORM TO THE 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD CONDITIONS TO 3. NO NOTE OR DETAIL OR LACK THEREOF SHALL BE CONSTRUED AS RELIEVING 2. THE CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHT AND CONSTRUCTION OPERATIONS WITH REGARD TO THE SAFETY OF THE PUBLIC CURRENT LOCAL PLUMBING CODE AND THE BUILDING CODES OF NEW YORK ASCERTAIN THAT ALL ITEMS ARE INSTALLED IN COMPLIANCE WITH THE (NFPA f� THE CONTRACTOR FROM THE EXECUTION OF THE WORK IN ACCORDANCE WITH POWER THROUGHOUT THE SPACE UNDER DEMOLITION'S REQUIRED TO PERFORM AND PROPERTY. FOR THE PURPOSE OF CHAPTER 33, CONSTRUCTION STATE AND LOCAL JURISDICTION. 70) NATIONAL ELECTRICAL CODE, THE 2020 NYS BUILDING CODE, ITS ALL STATE AND,/OR LOCAL CODES. SHOULD ANYTHING BE OMITTED FROM OPERATIONS SHALL INCLUDE EXCAVATION, ERECTION, ALTERATION, REPAIR, 4. ALL MATERIALS SHALL BE NEW UNLESS NOTED OTHERWISE. HIS WORK. REFERENCED CODES AND STANDARDS, AND LOCAL JURISDICTION. THE DRAWINGS, NECESSARY TO THE PROPER CONSTRUCTION OF THE WORK, 3. UPON COMPLETION OF DEMOLITION WORK, THE CONTRACTOR SHALL PROVIDE REMOVAL AND DEMOLITION AS RELATED TO BUILDINGS. FOR REGULATIONS 5. THE PLUMBING CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL LABOR 4. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO CALL FOR HEREIN DESCRIBED, IT SHALL BE THE DUTY OF THE CONTRACTOR TO NOTIFY THAT ALL AREAS BE LEFT BROOM CLEAN. RELATING TO THE SAFETY OF PERSONS EMPLOYED IN SUCH CONSTRUCTION AND MATERIALS INSTALLED UNDER THIS CONTRACT AND SHALL GUARANTEE FINISHED WORK, COMPLETE, TESTED AND READY FOR OPERATION. THE ARCHITECT/ENGINEER. 4. ALL ITEMS NOT BEING REUSED OR RETURNED TO THE BUILDING SHALL BE OPERATIONS, THE PROVISIONS OF SUBCHAPTER TEN OF THE LABOR LAW AS THE WORK PERFORMED UNDER THIS CONTRACT FOR A PERIOD OF EIGHTEEN 5. IT IS NOT INTENDED FOR THE DRAWINGS TO SHOW EVERY WIRE, CONDUIT OR K 18 MONTHS FROM THE DATE OF COMPLETION OF HIS WORK. 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. REMOVED FROM THE PREMISES, AND DISCARDED OUTSIDE OF THE VILLAGE IMPLEMENTED BY THE INDUSTRIAL CODE OF THE STATE OF NEW YORK, ( ) MINOR DETAIL AND IT IS UNDERSTOOD THAT WHILE THE DRAWINGS MUST BE r' ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER BOUNDARY, NO STOCKPILING OF ANY MATERIALS WILL BE PERMITTED UNLESS PART 23 PROTECTION IN CONSTRUCTION. DEMOLITION AND EXCAVATION 6. THE PLUMBING CONTRACTOR SHALL CONSULT AND COOPERATE WITH THE FOLLOWED AS CLOSELY AS FIELD CONDITIONS WILL PERMIT, THE SYSTEMS ' " BEFORE PROCEEDING. WRITTEN AUTHORIZATION S GIVEN BY THE VILLAGE. OPERATIONS . SHALL APPLY. IC CONTRACTOR, ETC. SHALL BE INSTALLED PROPERLY AND ACCORDING TO THE INTENT OF THE <" 5. THE CONTRACTCR SHALL ASSUME RESPONSIBILITY UNRELIEVED BY REVIEW OF 5. THE CONTRACTOR SHALL REMOVE ALL WALL CONDUITS LEFT AFTER WALL 2. THE CONTRACTOR SHALL INSTITUTE AND MAINTAIN SAFETY MEASURES AND IN ORDER TO AVOID INTERFERENCE DURING INSTALLATION OF WORK. CONTRACT DOCUMENTS AND ACCORDANCE TO INDUSTRY STANDARDS AND GOOD SHOP DRAWINGS OR PERIODIC OBSERVATION OF CONSTRUCTION, FOR DEMOLITION, INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY OTHER PROVIDE ALL EQUIPMENT OR TEMPORARY CONSTRUCTION NECESSARY TO 7. THE PLUMBING CONTRACTOR SHALL PREPARE AND FILE ALL REQUIRED PLANS PRACTICE. f� AND PERMITS WITH THE LOCAL AUTHORITIES AND COMPLIANCE WITH THE CONTRACT DOCUMENTS, FOR FABRICATION PROCESSES TELEPHONE OR ELECTRICAL WIRING AND EQUIPMENT. SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY THE CONTRACTORS TH TH A SHALL PAY ALL FILING FEES 6. AT THE END OF THE CONTRACT THE CONTRACTOR SHALL PROVIDE THE OWNER AND CONSTRUCTION TECHNIQUES AND FOR SAFE CONDITIONS ON THE JOB 6. THE CONTRACTOR SHALL REMOVE ALL EXISTING FINISHED FLOORING INCLUDING OPERATIONS. AS REQUIRED. HE SHALL OBTAIN ALL WORK PERMITS AND WRITE-OFFS AS AN UNDERWRITERS CERTIFICATE FROM AN ELECTRICAL UNDERWRITER APPROVED *`' SITE. TILE, COMPOSITION TILE, ADHESIVES, CARPETING, TACTLESS, ETC. 3. THE CONTRACTOR SHALL PROVIDE WARNING SIGNS, FENCES AND OTHER ITEMS REQUIRED TO EXECUTE THIS WORK IN A LEGAL MANNER. BY THE AUTHORITY HAVING JURISDICTION AND PROVIDE A COPY TO THE TOWN 6. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS OF 7. IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACTLESS, AS REQUIRED FOR THE PROPER PROTECTION OF WORKMEN ENGAGED IN 8. THE PLUMBING CONTRACTOR SHALL FURNISH TO THE OWNER ALL CERTIFICATES UPON COMPLETION OF THE INSTALLATION. CONSTRUCTION AND FOR SEQUENCES AND PROCEDURES TO BE USED. PARTITIONS, ETC. CAUSES AN UNEVENNESS IN THE FINISHED CONCRETE SLAB, DEMOLITION OR CONSTRUCTION OPERATIONS, THE PUBLIC AND ADJACENT OF INSURANCE REQUIRED BY LAW. 7. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE RESPONSIBLE Z 7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY UTILITY LOCATIONS AS THE CONTRACTOR SHALL PATCH TO LEVEL THE SLAB TO RECEIVE NEW CONSTRUCTION. 9. THE PLUMBING CONTRACTOR SHALL PURGE AND DISINFECT ALL NEW DOMESTIC TRADES TO CUT AND PATCH REPAIR ALL WALL CEILING AND FLOOR WELL AS OTHER UTILITY LOCATIONS THAT MAY OR MAY ARANTEED T RE SHOWN. OD OF FINISHED FLOOR.' 4 PASSAGEWAYSTHE TOORSHALL NOT STAIRWAYSCLOSE OR THE CONTRACTOR SHALL NOT PLUMBING OR THE LOCALPIPING AUIHORNiY HAVINGD ANY FECTED JURISDC1110NNG PIPING, IN ACCORDANCE WITH PENETRATIONS TO MATCH 8 ALL FIRE RATED ASSEMBLIESSTING BE FlRIAL AND E STOPPED FINISHES.MINMUM 2 HOURS • LOCATI 8. ALL MATERIALS AND WORKMANSHIP SHALL BEG F A 8. THE CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISH SURFACES ALL ( ) LOCATION M A P EIGHTEEN (18) MONTHS AFTER COMPLETION BY THE CONTRACTOR. THE PROJECTING PLUMBING, ELECTRICAL, TELEPHONE AND ALL OTHER PROJECTING PLACE MATERIALS IN PASSAGEWAYS, STAIRS, OR OTHER MEANS OF EGRESS. 10. THE PLUMBING CONTRACTOR SHALL INSTALL ALL PIPING CONCEALED IN WALLS SUBMIT U.L DETAIL FOR APPROVAL. 5. NO STRUCTURE, DEVICE OR CONSTRUCTION EQUIPMENT, WHETHER PERMANENT AND OR CEILINGS UNLESS OTHERWISE INDICATED. EXPOSED PIPING SHALL BE 9, ALL MATERIALS AND EQUIPMENT SHALL BE LISTED AND INSTALLED PER THE N.T.S. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THE GUARANTEE. ITEMS WHICH ARE BEING ABANDONED.9. ALL MATERIALS SHALL BE NEW UNLESS OTHERWISE SHOWN. ALL 9. DEMOLITION WORK SHALL BE DONE IN STRICT CONFORMANCE WITH LOCAL OR TEMPORARY, INCLUDING ALL PARTLY OR FULLY COMPLETED ELEMENTS OR NEATLY RUN PARALLEL OR PERPENDICULAR TO WALLS AND CEILINGS. PIPING MANUFACTURER'S WRITTEN INSTRUCTIONS. WORKMANSHIP SHALL BE FIRST CLASS AND STATE REGULATIONS. SECTIONS OF THE BUILDING, SHALL BE LOADED IN EXCESS OF ITS DESIGN ABOVE ACCESSIBLE CEILINGS SHALL ALLOW THE REMOVAL OF CEILING TILES CAPACITY. FOR PLENUM ACCESS. 10. FINISHES AND COLOR SELECTION OF MATERIALS DEVICES EQUIPMENT AND 10. ANY DEFECTIVE WORK AND DAMAGE RESULTING THE WORK SHALL BE 10. PERFORM ALL DEMOLITION WORK IN ACCORDANCE WITH THE REGULATIONS 11. THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO ALL FIXTURES FROM MANUFACTURER'S STANDARD RANGE SHALL SELECTED AND ENGINEER: REPAIRED AND/OR REPLACED AS REQUIRED AT NO COST TO THE OWNER BY OF ANSI/NFPA 241-2013 BUILDING CONSTRUCTION AND DEMOLITION 6. ALL BUILDING MATERIALS STORED AT THE CONSTRUCTION AREA, AND/OR IN VERIFIED BY THE OWNER. THE CONTRACTOR. OPERATIONS. THE AREA OF THE BUILDING, SHALL BE SECURED IN A LOCKED AREA. PLUMBING EQUIPMENT REGARDLESS OF WHETHER SHOWN HEREIN WITHOUT ANY 11. PROVIDE ALL REQUIRED PULL BOXES AND HARDWARE FOR ALL CONDUIT RUNS. 11. ALL WORK IS TO BE PLUMB, LEVEL AND TRUE. 11. PROVIDE ALL TEMPORARY BARRICADES, RAILING, LIGHTING, ETC. REQUIRED ACCESS TO SUCH AREAS SHALL BE CONTROLLED BY THE CONTRACTOR AND ADDITIONAL COSTS TO THE OWNER. ALL CONDUIT RUNS SHALL BE PROPERLY SUPPORTED. 12. ALL WORK SHALL BE EXECUTED IN SUCH A MANNER AS TO PROTECT THE TO PROTECT THE WORKMEN, OWNER. NO HAZARDOUS MATERIAL SHALL BE STORED ON SITE WITHOUT 12. THE PLUMBING CONTRACTOR SHALL PERFORM ALL CUTTING, EXCAVATION, OWNER PERSONNEL, AND OTHERS FROM INJURY 12. ALL EQUIPMENT SHALL BE NEW UNLESS OTHERWISE NOTED. SAFETY OF WORKMEN AND THE PUBLIC DURING CONSTRUCTION. ALL DUE TO THE DEMOLITION WORK. PROVIDE FREE AND SAFE PASSAGE OF AUTHORIZATION OF THE OWNER AND IN ACCORDANCE WITH VILLAGE BACKFILLING, E C. AS REQUIRED FOR THE INSTALLATION OF THE WORK AND 13. BALANCE PANEL BOARDS EQUALLY OVER ALL PHASES. BARRIERS AND OTHER PRECAUTIONARY MEASURES SHALL BE ERECTED IN PERSONS TO AND FROM AREAS AND FACILITIES WHICH ARE TO REMAIN. REQUIREMENTS. SHALL PERFORM ALL FINAL PATCHING BACK TO ORIGINAL STATE, UNLESS 7. THE CONTRACTOR SHALL KEEP ALL FLAMMABLE MATERIALS TIGHTLY SEALED OTHERWISE NOTED. 14. ALL EQUIPMENT INSTALLED INDOORS SHALL HAVE A NEMA 1 RATING AND ALL ACCORDANCE WITH THE AUTHORITIES HAVING JURISDICTION OR AS REQUIRED 12. PERFORM THE DEMOLITION WORK IN SUCH A MANNER AS TO PREVENT FIRES. EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3 RATING. 13. THE PLUMBING CONTRACTOR SHALL PERFORM ALL TESTS REQUIRED BY THE FOR SAFETY DURING THE ENTIRE CONSTRUCTION OPERATION. REMOVE ALL ACCUMULATED DEBRIS PROMPTLY. DISPOSAL BY BURNING WILL IN THE MANUFACTURES CONTAINERS WHEN NOT IN USE. SUCH MATERIALS 15. PROVIDE LIQUID-TIGHT FLEXIBLE CONDUIT CONNECTIONS FOR ALL EQUIPMENT 13. THE CONTRACTOR SHALL USE ADEQUATE NUMBERS OF SKILLED WORKMEN WHO NOT BE PERMITTED ON SITE. ALL DEBRIS SHALL BE DISPOSED OF IN A LEGAL ARE TO BE KEPT AWAY FROM HEAT. LOCAL AUTHORITIES HAVING JURISDICTION AND ARRANGE FOR ALL INSPECTIONS SUBJECT TO VIBRATION. AS REQUIRED AT NO ADDITIONAL COST. ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS WORKMANLIKE MANNER. DO NOT BURY MATERIALS ON SITE. 8. ALL FLAMMABLE MATERIALS SHALL BE USED IN AN ADEQUATELY VENTILATED 14. ALL NEW CONNECTIONS NO TO NEW AND/OR EXISTING EQUIPMENT SHALL BE 16. ALL PANEL BOARDS AND ELECTRICAL DISTRIBUTION EQUIPMENT SUPPLIED L. K. MCLEAN ASSOCIATES AND WHO ARE COMPLETELY FAMILIAR WITH THE REQUIREMENTS AND METHODS 13. ALL SALVAGEABLE MATERIALS AND EQUIPMENT, INCLUDING PLUMBING FIXTURES, SPACE. PERFORMED IN ACCORDANCE WITH THE CODE AND THE EQUIPMENT UNDER THIS CONTRACT SHALL BE PROVIDED WITH PHENOLIC NAMEPLATES NEEDED FOR PROPER PERFORMANCE OF THE WORK NOTED ON THE PLANS. FURNISHINGS, AND DECOR ITEMS SHALL BE STORED AND PROTECTED FROM 9. ALL ELECTRICAL POWER SHALL BE SHUT OFF WHERE THERE IS EXPOSED INDICATING THE PANEL NAME. ENGINEERING & SURVEYING, D.P.C. 14. THE CONTRACTOR SHALL COORDINATE HIS ACTIVITIES WITH THE OWNER AND DAMAGE UNTIL THE OWNER DETERMINES THE COURSE OF ACTION TO BE TAKEN CONDUIT. MANUFACTURERS RECOMMENDATIONS. 17. THE ELECTRICAL CONTRACTOR AT HIS/HER DISCRE11ON MAY COMBINE HOME CONSULTING ENGINEERS 437 SOUTH COUNTRY RD.,BROOKHAVEN,NEW YORK 11719 ARCHITECT/ENGINEER DURING CONSTRUCTION. 14. NOTIFY AFFECTED UTILITY COMPANIES BEFORE STARTING WORK AND COMPLY 10. ALL FIRE RETARDANT TREATED WOOD SHALL COMPLY WITH NEW YORK STATE 15. THE CONTRACTOR SHALL PROVIDE DEMONSTRATION AND TRAINING TO THE RUNS. WITH THEIR REQUIREMENTS. BUILDING CODE SECTION 2303.2. OWNER FOR ALL EQUIPMENT AND SYSTEMS INSTALLED; PROVIDE A REPORT OF 18. THE ROUTING OF CONDUITS AND LOCATIONS OF PANELS SHOWN ON THE PLANS 15. DO NOT DISABLE OR DISRUPT BUILDING FIRE SAFETY SYSTEMS WITHOUT PRIOR 11. ALL ELECTRICAL POWER ON THE CONSTRUCTION SITE SHALL BE SHUT OFF ALL OPERATING PARAMETERS ALONG WITH A MAINTENANCE SCHEDULE PER THE IS DIAGRAMMATIC ONLY AND SUBJECT TO SUCH MODIFICATIONS- WITHOUT REFLECTED CEILING NOTES WRITTEN NOTICE TO OWNER' AFTER WORKING HOURS. MANUFACTURER RECOMMENDATIONS. EXTRA COST TO THE OWNER- AS EXISTING CONDI1ONS NECESSITATE. IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE 16. PROVIDE DUST-TIGHT PARTITIONS BETWEEN AREAS WHERE DEMOLITION WORK IS 12. THE CONTRACTOR SHALL REGULARLY VERIFY THAT THERE IS NO LEAKAGE OF 16. ALL SANITARY AND STORM PIPING INSTALLED ABOVE GROUND SHALL BE CAST BEING PERFORMED AND AREAS WHICH ARE FINISHED OR IN USE. NATURAL GAS IN THE BUILDING, OR ANY FLAMMABLE GAS USED IN IRON WITH "NO-HUB" JOINTS OR GALVANIZED WITH DRAINAGE PATTERN DIRECTION E A LICENSED ARCHITECT ENGINEER, TO ALTER F ANY WAY ANY 1. EACH PRIME CONTRACTOR SHALL COORDINATE REFLECTED CEILING PLAN WITH FITTINGS FOR SANITARY AND STORM WASTE PIPING AND MALLEABLE FITTINGS GENERAL LIGHTING ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ELECTRICAL, MECHANICAL, AND SPRINKLER DRAWINGS FOR OTHER WORK AND 17. CONFORM TO PROCEDURES APPLICABLE WHEN DISCOVERING HAZARDOUS OR CONSTRUCTION. NOTES ENGINEER IS ALTERED,THE ALTERING ARCHITECT ENGINEER SHALL AFFIX TO CONTAMINATED MATERIALS. 13. CONTRACTOR HAS TO MAINTAIN ACCESS AND EMERGENCY EXITS OF THE FOR VENT LINES. HIS/HER ITEM THEIR SEAL AND THE NOTATION 'ALTERED BY' FOLLOWED BY APPURTENANT INSTALLATIONS WHICH MAY EFFECT THE CEILING WORK. HISMER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A -SPECIFIC 2. SUBMIT SHOP DRAWINGS OF ALL LIGHT FIXTURES FOR APPROVAL. 18. CONDUCT DEMOLITION TO MINIMIZE INTERFERENCE WITH ADJACENT BUILDING AND AVAILABILITY OF ALL UTILITIES WITHOUT ANY DISRUPTION FOR 17. ALL COLD AND HOT WATER LINES SHALL BE "L" COPPER TUBING WITH CAST 1. PROVIDE LIGHT FIXTURES AS SPECIFIED, IN LOCATIONS SHOWN, INSTALLED PER DESCRIPTION OF THE ALTERATION ON THE DRAWING. " THE PLANS AND OCCUPANCIES. OCCUPANTS THROUGHOUT THE CONSTRUC110N PHASE. BRASS OR WROJGHT COPPER FITTINGS AND SOLDER JOINTS AS PER THE MANUFACTURE'S INSTRUCTIONS AND THE NEC. SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A 3. THE EXACT LOCATION OF FIXTURES MAY BE MODIFIED IN FIELD AS REQUIRED 19. CEASE OPERATIONS IMMEDIATELY IF STRUCTURE APPEARS TO BE IN DANGER. 14. THE CONTRACTOR SHALL NOT DISTURB ASBESTOS OR ANY MATERIAL PLUMBING CODE. RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. AND AS DIRECTED BY ARCHITECT. 2. FULLY COORDINATE ALL LIGHTING FIXTURE LOCATIONS WITH ALL OTHER CEILING MCLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE NOTIFY ARCHITECT/ENGINEER. DO NOT RESUME OPERATIONS UNTIL DIRECTED. SUSPECTED ON CONTAINING ASBESTOS. FOLLOW THE ABATEMENT 18. ALL COLD AND HOT WATER PIPING AND FITTINGS SHALL BE COVERED WITH A MOUNTED DEVICES, WITH ALL OTHER TRADES AND WITH THE OWNER. SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY 4. CEILING ARCHITECTURE IS ACCESSIBLE, PROCEDURES REQUIRED BY THE NEW YORK STATE CODE PART 56 MINIMUM COVERNG OF 1 MOLDED FIBERGLASS PIPE INSULATION WITH A ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.MCLEAN ASSOCIATES,PC 20. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. PROTECT EXISTING 3. LIGHTING TO BE MOUNTED AND CONNECTED TO BOTTOM CHORD OF TRUSS. SUPPORTING STRUCTURAL MEMBERS. . DEPARTMENT OF LABOR. MAXIMUM "K" FACTOR OF .24 AT A TEMPERATURE OF 75 DEGREES F. FOLLOW MANUFACTURER INSTRUCTIONS. 21. PATCH ALL EXISTING FINISHES TO REMAIN THAT ARE AFFECTED BY ADJACENT FITTINGS, VALVES AND VALVE ASSEMBLY COMPONENTS SHALL BE INSULATED 4. LIGHTING CIRCUITS ARE SHOWN FOR DESIGN INTENT ONLY. PROVIDE A NEW ©L.K. McLEAN ASSOCIATES ENGINEERING &SURVEYING, D.P.C. DEMOLITION WORK NOT SPECIFICALLY INDICATED ON THE DRAWINGS. PATCHED WITH MOLDED INSULATION WITH THE SAME THERMAL CHARACTERISTICS. DEDICATED CIRCUIT WIRING BACK TO NEAREST SUB PANEL. WORK SHALL BE FINISHED AND ALIGN WITH EXISTING ADJACENT SURFACES. 19. ALL PIPE HANGERS AND SUPPORTS SHALL BE AS PER THE CODES OF NEW 5. PRIOR TO ORDERING LIGHT FIXTURES, COORDINATE REQUIREMENTS WITH THE 22. PROVIDE DEMOLITION WORK AND PROTECT THE BUILDING FROM WATER AND ACCESSIBILITY NOTES YORK STATE. OWNERS REPRESENTATIVE AND THE CONTRACT DOCUMENTS, IF DISCREPANCIES PROJECT: WEATHER PENETRATION DURING ROOF TIE-INS AND ROOF FLASHING WORK. 20. ALL NEW PLUMBING FIXTURES SHALL BE INSTALLED WITH ANGLE STOP VALVES EXIST THE OBTAIN CLARIFICATION BEFORE PROCEEDING. LIGHT GAUGE METAL FRAMING 23. ALL DEBRIS AND ADDITIONAL MATERIAL (DEEMED BY OWNER) SHALL BE 1. ALL DIMENSIONAL ACCESSIBLE CRITERIA TOILET DRAWINGS ARE BASED ON ICC IN THE SUPPLY LINES BELOW THE FIXTURES. 6. PROVIDE LIGHTING CONTROL WITH VARIABLE TIMED VACANCY SENSORS AT REMOVED FROM THE SITE AND DISPOSED OF PROPERLY. A117.1-2009. 21. ALL NEW FIXTURE SUPPLY PIPING AND WASTE PIPING SHALL BE CHROME SWITCH LEVEL (AUTOMATIC ON/ AUTOMATIC OFF), UNLESS OTHERWISE TOWN OF SO UTH O LD 1. ALL WORK TO BE DONE IN ACCODANCE WITH THE 2020 NYS BUILDING CODE. 24. ANY ITEM REMOVED FROM THE SPACE SHALL BE TURNED OVER TO THE OWNER 2. IN NEW CONSTRUCTION, ALL PUBLIC AND COMMON USE TOILET ROOMS ARE PLATED AND SHALL HAVE CHROME PLATED ESCUTCHEONS INSTALLED AT THE INDICATED BY THE OWNER. 2. ALL LIGHT GAUGE METAL FRAMING MEMBERS SHALL BE BY MARINO WARE OR IN UNDAMAGED CONDITION TO THE OWNER IF REQUESTED. GENERALLY REQUIRED TO BE ACCESSIBLE. PENETRATIONS THROUGH THE WALLS. 7. TEST OCCUPANT SENSOR CONTROL: -VERIFY THAT LIGHTING TURNS OFF SUFFOLK COUNTY NY APPROVED EQUAL. INSTALL FRAMING IN ACCORDNACE WITH THE 3. THE ACCESSIBLE ROOMS MUST BE IDENTIFIED BY SIGNS. 22. ALL NEW VALVES SHALL BE "FAIRBANKS" OR EQUAL RATED AT 125 PSIG, WOG, WITH-IN THE REQUIRED TIME.- VERIFY THAT LIGHTS TURN ON TO THE MAUNUFACTURER'S STANDARD DETAILS AND SPECIFICATIONS AS WELL AS THE 4. IN ACCESSIBLE TOILET AND BATHING ROOMS, AT LEAST ONE OF EACH TYPE OF OR APPROVED EQUAL. PERMITTED LEVEL WHEN AN OCCUPANT ENTERS THE SPACE.- VERIFY THAT STEEL STUD MANUFACTURERS ASSOCIA11ON DETAILS (WWW.SSMA.COM) NOISE CONTROL FIXTURE AND ACCESSORY PROVIDED MUST BE ACCESSIBLE. 23. ANY HOSE BIB SHALL BE FROST-PROOF TYPE AND SUPPLIED WITH VACUUM LIGHTS ARE NOT INCORRECTLY TURNED ON BY MOVEMENT IN ADJACENT AREAS 5. 3. PROVIDE HORIZONTAL BRIDGING AT 4 FT ON CENTER VERTICALLY IN ALL A WHEELCHAIR TURNING SPACE IS REQUIRED WITHIN ACCESSIBLE TOILET AND BREAKERS. WALL HYDRANTS SHALL BE KEY OPERATED, FROST PROOF AND AND OR BY HVAC OPERATION. FRAMED WALLS. BATHING ROOMS. SUPPLIED WITH VACUUM BREAKERS, SIMILAR TO J.R. SMITH. O U T O 4. PROVIDE TWO 6J16 HEADERS OVER ALL OPENINGS UNLESS OTHERWISE NOTED. 1. CONSTRUC11ON OPERATIONS SHALL BE CONFINED TO NORMAL WORKING HOURS: 6. DOORS ARE NOT PERMITTED TO SWING INTO THE REQUIRED CLEAR FLOOR 24. PIPE SLEEVES SHALL BE INSTALLED AT ALL PENETRA11ONS THROUGH WALLS LD GENERAL POWER NO TES 5. ALL MEMBERS TO BE 20 GAGE MINIMUM. 7:30 A.M. TO 3:30 P.M., (AND AS PER LOCAL JURISDICTION), MONDAYS SPACE AT ANY FIXTURE, EXCEPT IN SINGLE-USER ROOMS, WHERE A CLEAR AND FLOORS. T RECREATION CENTER 6. PROVIDE FULL HEIGHT 2X4 REINFORCING AT DOOR JAMBS. THROUGH FRIDAYS, EXCEPT NO WORK SHALL BE PERFORMED ON LEGAL FLOOR SPACE IS PROVIDED BEYOND THE SWING OF THE DOOR. 25. WATER HAMMER ELIMINATORS SHALL BE INSTALLED ON ALL DROPS IN THE 7. FOR ACCESSIBLE ROUTE, SEE ICCA117.1-2009. WATER LINES SERVING THE TOILET ROOMS AND OTHER AREAS. �T RO O 7. PROVIDE BACKER PLATE AT ALL TOILET ROOM ACCESSORIES AND PLUMBING HOLIDAYS. THE CONTRACTOR SHALL OBTAIN THE WRITTEN CONSENT FROM THE 26. BALL VALVES FOR WATER SYSTEM SHALL BE BRONZE BODY WITH CHROME 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, FIXTURES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. OWNER TO PERFORM WORK AT TIMES OTHER THAN THE HOURS STATED ABOVE PLATED BRONZE BALL, STAINLESS STEEL HANDLE,BRONZE BOY SEATS AND SEALS UTILITY STANDARDS TOWN AND 2020 N.Y.S. CODES. 8. BRACE TOP OF WALL 0 EXISTING ROOF STRUCTURE AS INDICATED. AND THE WORK SHALL COMPLY WITH REQUIREMENTS FOR NOISE CONTROL AS 2. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING HM DOOR NOTES RATED PSIG WOG. RENOVATIONS STIPULATED IN SECTION 1207 OF NEW YORK STATE CODE. UNINTERRUPTED TEMPORARY POWER TO ALL TRADES DURING CONSTRUCTION. 27. FLOOR DRAINS SHALL INCLUDE TRAP PRIMERS. 2. THE CONTRACTOR SHALL USE ALL AVAILABLE MEANS TO MINIMIZE THE ELECTRICAL CONTRACTOR SHALL MAINTAIN TEMPORARY POWER DURING 28. PLUMBING FIXTURES INSTALLATION SHALL INCLUDE CARRIERS AND CLIPS AS CONSTRUCTION NOISE ON WEEKENDS BETWEEN 7:30 A.M. AND 3:30 P.M. 1. ALL DOOR FRAMES SHOWN NEAR INSIDE CORNERS OF WALL SHALL BE LOCATED CONSTRUCTION AND REMOVE ALL TEMPORARY POWER AT THE END OF THE NYS BUILDING CODE NOTES 3. IF APPROVAL IS GIVEN BY THE OWNER TO WORK ON A HOLIDAY, THE A DISTANCE OF 4" FROM THE THROAT RETURN TO THE CLOSEST ADJACENT PER MANUFACTURER INSTRUCTIONS. THE CONTRACTOR SHALL VERIFY EXISTING CONTRACT. CONTRACTOR WILL BE RESPONSIBLE TO REIMBURSE THE OWNER FOR THE COST PERPENDICULAR PARTITION, UNLESS OTHER WISE NOTED TO ACCOMMODATE WALLS FOR VEPTICAL PLUMB, FLATNESS AND STRENGTH TO INSURE PROPER 3. THE CONTRACTOR SHALL NOT INTERRUPT THE OWNERS POWER. OF OVERTIME TO HAVE AN OWNERS REPRESENTATIVE ON SITE. ADA MANEUVERING CLEARANCES. FIT, POSITIONING AND CLEARANCES. 4. THE EXACT LOCATIONS OF THE OUTLETS AND SWITCHES SHALL BE 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF 2020 NEW YORK STATE 4. THE CONTRACTOR SHALL EQUIP ALL MACHINERY AND EQUIPMENT USED FOR 2. ALL WALL STOPS LOCATED IN GYPSUM WALLS SHALL HAVE METAL PLATE OR COORDINATED WITH THE OWNER PRIOR TO INSTALLATION. 970 PECONIC LANE BUILDING CODE. CONSTRUCTION WITH NOISE CONTROL DEVICES SUCH AS MUFFLERS FOR FIRE TREATED WOOD BLOCKING INSIDE THE WALL. PAINTING 5. CONFIRM AND COORDINATE FINAL ELECTRICAL REQUIREMENTS, PECONIC, NY 11958 2. BEFORE COMMENCING WORK THE CONTRACTOR SHALL PAY ALL FEES AND INTERNAL COMBU'S11ON ENGINES OR OTHER SUITABLE NOISE SUPRESSORS. 3. DOORS AND FRAMES SHALL BE 14 GAGE. FRAMES SHALL BE WELDED CONNECTIONS,AND LOCATIONS WITH ACTUAL SUPPLIED EQUIPMENT. OBTAIN ALL WORK AND EQUIPMENT USE PERMITS AS REQUIRED BY THE CITY, 5. NOISE PRODUCED BY CONSTRUCTION OPERATIONS SHALL BE KEPT TO A ASSEMBLY, NO KNOCK DOWN ASSEMBLIES WILL BE ACCEPTED. 6. VERIFY AND CONFIRM RECEPTACLE SIZES AND LOCATIONS WITH OWNER AND TOWN, STATE OR FEDERAL AGENCIES HAVING JURISDICTION OVER THE WORK. MINIMUM AND SHALL BE CONSISTENT WITH REASONABLE HUMAN HEALTH 4. DOORS SHALL BE FLUSH, BOTTOM LOUVERED, 1-3/4" THICK, 16 GAGE 1. PROVIDE PAINT FINISH SYSTEMS WHEREVER PAINT IS INDICATED, SCHEDULES OR EQUIPMENT MANUFACTURER REQUIREMENTS. ALL RECEPTACLES AND 3. COMMENCEMENT OF OPERATIONS: NOTIFY IN ADVANCE THE VILLAGE OF REQUIREMENTS CONSIDERING TIME OF DAY AND LOCATION OF WORK SITE. MINIMUM, EXTRA HEAVY DUTY SEAMLESS CONSTRUCTION PER STEEL DOOR SPECIFIED. SWITCHES SHALL BE SURFACE MOUNTED ON EXISTING MASONRY UTILIZING ISSUES/REVISIONS GARDEN CITY APPOINTED REPRESENTATIVE BEFORE COMMENCING THE WORK. 6. CONTRACTOR SHALL COMPLY WITH APPLICABLE NEW YORK STATE NOISE INSTITUTE (SDI 108-2018). 2. ALL GYPSUM BOARD TO BE PAINTED. ALL EXISTING MASONRY TO BE PAINTED. NON METALLIC RIGID CONDUIT AND NONMETALLIC SURFACE MOUNTED BOXES. 4. CONCEALED SPACES WITH PARTITIONS, WALL, FLOORS, ROOFS, STAIRS, FURRING POLLUTION CONTROL REGULATIONS. 5. UNDERCUT DOOR 3/4". ROOF TRUSSES TO BE PAINTED. ROOF DECK T BE PAINTED. ALL EXPOSED 7. THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT THERE IS SUFFICIENT Description No. Date PIPE SPACES, COLUMN ENCLOSURES, ETC. SHALL BE FIRE STOPPED WITH PIPING TO BE FAINTED. ALL EXPOSED SPRINKLER PIPING TO BE PAINTED PER POWER AVAILABLE FOR ALL ELECTRICAL EQUIPMENT. NON-COMBUS1113LE MATERIAL THAT CAN BE SHAPED, FITTED AND 6. COORDINATE HARDWARE WITH OWNERS REQUIREMENTS AND ACCESSIBILITY NFPA REQUIREMENTS 8. PRIOR TO PRICING, ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL PERMIT RENEWAL: FINISH COLORS 1 01-10-2025 PERMANENTLY SECURED IN POSITION AS PER CHAPTER 7 OF THE NEW YORK DUST CONTROL STANDARDS. HARDWARE SET TO INCLUDE 3 HINGES; MORTISE LEVER LOCKSET, 3. PAINT FINISH SHALL EXTEND FULLY TO ADJOINING NON-PAINTED SURFACES ITEMS, AND EQUIPMENT SHOWN ON THE DRAWING AND INCLUDE ITEMS AND CLOSER, SILENCERS AND WALL STOP. AND MASKED WTH TAPE SUCH AS WOOD OR ACOUSTICAL CEILINGS OR EQUIPMENT SHOWN ON THE DRAWING AND INCLUDE IN HIS HER PRICING STATE CODE. SUBMIT U.L. DETAIL FOR APPROVAL. 7. PROVIDE HARDWARE COMPONENTS AS LISTED BELOW. ALTERNATE TO SPECIFIED 5. DUCTS, PIPES AND CONDUITS PASSING THROUGH FIRE RATED CONSTRUCTION 1. THE CONTRACTOR SHALL CONDUCT OPERATIONS AND MAINTAIN THE PROJECT ITEM WILL BE ACCEPTABLE PENDING REVIEW AND APPROVAL BY ARCHITECT. EXISTING FINISHES TO REMAIN. ANY LABOR OR MATERIALS REQUIRED FOR A COMPLETE OPERATIONAL4. SUBMIT AT LEAST THREE SAMPLES OF EACH PAINT COLOR ON MEDIUM SYSTEM AS PER MANUFACTURER REQUIREMENTS AND APPLICABLE CODES. SHALL HAVE SURROUNDING SPACES NOT EXCEEDING (1/2") IN WIDTH PACKED SITE SO AS TO MINIMIZE THE CREATION AND DISPERSION'OF DUST. DUST 7.1. BUTT HINGES TOTAL USE STANLEY #FB8199 BALL BEARING FULL MORTISE; SHOWING THE ACTUAL COLOR AND CEEEN OF PAINT. SUBMIT MANUFACTURER'S WITH FIRE STOPPING MATERIAL APPROVED BY THE CODE AND CLOSED OFF CONTROL SHALL BE USED THROUGHOUT THE WORK AT THE SITE. OR EQUAL BY HAGER OR MCKINNEY. STAINLESS STEEL SATIN FINISH. LITERATURE AND SPECIFICATIONS FOR EACH PAINT SYSTEM SPECIFIED. WITH CLOSE FITTING METAL CLOSURES. DUCTWORK PENETRATIONS SHALL BE 2. THE CONTRACTOR MUST PROVIDE CLEAN WATER, FREE FROM SALT, OIL AND 7.2. LOCK SETS STANDARD MATCH EXISTING HARDWARE BRAND HARDWARE WHERE MANUFACTURER OTHER THAN ONE SCHEDULED.5. PROTECTED BY RATED SELF CLOSING DEVICES PER 2020 NYS BUILDING CODE OTHER DELETERIOUS MATERIAL TO BE USED FOR ON-SITE DUST CONTROL. SHALL BE LEVER HANDLES TO MEET ADA. CONFIRM LOCKING PROVIDE THE PAINT FIRE DETECTION /ALARM N 0 TE S CHAPTER 7 AT ALL PENETRATIONS. SUBMIT U.L. DETAIL FOR APPROVAL.. 3. THE CONTRACTOR SHALL SUPPLY WATER SPRAYING EQUIPMENT CAPABLE OF REQUIREMENTS WITH OWNER. MANUFACTURER'S EQUAL FOR APPROVAL. 6. THE MINIMUM FIRE RESISTANCE RATINGS (2 -HOURS) SHALL BE PROVIDED FOR ACCESSING ALL WORK AREAS. 7.3. CLOSERS USE LCN 4010 SERIES FOR PUSH SIDE MOUNTING OR APPROVED 6. EXAMINE SURFACES TO BE PAINTED AND REPORT ANY CONDITIONS THAT 1. FIRE ALARM SYSTEM NOT TO BE EFFECTED DURING CONSTRUCTION CONSTRUC11ON ELEMENTS OR AS REQUIRED FOR THE CONSTRUC11ON CLASS, 4. THE CONTRACTOR SHALL IMPLEMENT STRICT DUST CONTROL MEASURES. EQUAL. WOULD ADVERSELY AFFECT THE APPEARANCE OR PERFORMANCE OF THE AND AS INDICATED ON THE CERTIFICATE OF OCCUPANCY OR APPROVED 5. DURING ACTIVE CONSTRUCTION PERIODS ON-SITE, THESE CONTROL MEASURES 7.4. WALL BUMPER USE IVES WS402CCV OR APPROVED EQUAL. PAINTING SYSTEMS AND WHICH CANNOT BE PUT INTO AN ACCEPTABLE BUILDING PERMIT APPLICATION. WILL GENERALLY CONSIST OF WATER APPLICATIONS THAT SHALL BE APPLIED A 7.5. MECHANICALLY FASTENED SILENCERS (3 PAIR PER SINGLE DOOR). CONDITION BY SPECIFIED SURFACE PREPARATION. PAINT APPLICATOR SHALL MINIMUM OF ONCE PER DAY DURING DRY WEATHER OR OFTEN AS REQUIRED TO 8, CONTRACTOR SHALL SUBMIT CATALOG CUTS FOR EACH ITEM. NOTIFY THE CONTRACTOR OF ANY REMEDIAL WORK REQUIRED TO THE MECHANICAL NOTES PREVENT DUST EMISSIONS. 9. MOUNT HARDWARE IN ACCORDANCE WITH THE DOOR AND HARDWARE INSTITUTE SUBSTRATE. RECOMMENDED LOCATIONS FOR BUILDERS HARDWARE FOR STANDARD STEEL 7• PRIOR TO ALL SURFACE PREPARATION AND APPLICATION OPERATIONS, DOORS AND FRAMES, UNLESS OTHERWISE NOTED. COMPLETELY MASK, REMOVE OR OTHERWISE PROTECT GLASS, FACTORY 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2020 N.Y.S. MECHANICAL FINISHED SURFACES, WOODWORK, PLUMBING FIXTURES, LIGHT FIXTURES, AND CODES. ' SHOP PRIME EXPOSED SURFACES FRAME AND DOOR SURFACES, INCLUDING SIMILAR ITEMS NOT SCHEDULED TO RECEIVE PAINT FINISH. 2. THE CONTRACTOR SHALL SUBMIT CATALOG SPECIFICATION DATA AND SHOP GALVANIZED SURFACES USING MANUFACTURER'S STANDARD BAKED ON RUST 8, ALL SURFACES TO BE CLEAN, DRY AND ADEQUATELY PROTECTED FROM DRAWINGS FOR APPROVAL BY THE ARCHITECT. INHIBITIVE PRIMER. DAMPNESS PRICR TO COATING. 3. INSTALL ALL EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE AND REPAIR 9. STRICTLY FOLLCW THE MANUFACTURER'S GUIDE SPECIFICATIONS FOR STORAGE, OR REPLACEMENT OF COMPONENTS. HANDLING AND APPLICATION TO MAINTAIN SATISFACTORY WORK. 4. CONNECT EQUIPMENT FOR EASE OF DISCONNECTING, WITH MINIMUM 10. APPLY PAINT FINISH IN ACCORDANCE WITH MANUFACTURE'S INSTRUCTIONS AND INTERFERENCE TO OTHER INSTALLATIONS. COVERAGE RATE. 5. FURNISH AND INSTALL ALL WALL PENETRATIONS FOR A PERMANENT WATER STATUS: 11. APPLIED PAINT FINISH SHALL MATCH APPROVED SAMPLES AND SHALL BE FREE TIGHT CONDITION. OF RUNS, SAGS, AND EXCESSIVE IRREGULARITY/UNEVENNESS OF PATTERN 6. FTHE OR ALL CONTRACTOR A TOR SHALL PERFORM SYSTEMS. STING, ADJUSTING AND BALANCING NOT FOR CONSTRUCTION COAT. 1RANSI114NS BETWEEN COLORS AND TERMINATIONS AT ADJOINING IV MATERIALS SHAD- BE SHARP, CLEAN AND WITHOUT OVERLAPS. 7, FAN FUNCTIONAL TESTING SHALL DEMONSTRATE THE INSTALLA110N AND Z 12. FOLLOWING APPJCATION, REMOVE ANY PAINT SPATTERS FROM ADJOINING OPERATION OF COMPONENTS, SYSTEMS AND SYSTEM TO SYSTEM INTERFACE DRAWING TITLE: o, SURFACES. REPAIR ANY DAMAGED OR IMPERFECT AREAS OF EACH PAINT IN ACCORDANCE TO THE CONTRACT DOCUMENTS AND MANUFACTURER 3 FINISH IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. INSTALLATION DIRECTIONS. 8. VENTILATION CONTROLS SHALL BE TESTED TO DOCUMENT THAT CONTROL DEVICES, COMPONENTS AND SYSTEMS ARE CALIBRATED AND ADJUSTED TO p OPERATE TO MINIMUM CODE REQUIREMENTS AND IN ACCORDANCE WITH THE GENERAL u VJ E o CONTRACT DOCUMENTS. a 9. COORDINATE VENTILATION CEILING FAN WALL CONTROLS WITH IN A COMMON +- GANG BOX FOR LIGHTING CONTROLS WITH THE ELECTRICAL CONTRACTOR. 2 10. COORDINATE CEILING GRILL COLOR TO MATCH THE CEILING COLOR AND SEAL 8 Design By: 7G INSTALL WITH THE HUNG CEILING SYSTEM. OFNF Drawn By: ]R N �oOERT �; s�/- Approved By: CFD Scale: AS NOTED *� o ^ Date: JAN. 2025 c� in oo File No: 21193.000 N M o o A 0�, . �° l� Sheet No. FULL SIZED PLOT SIZE:24"x 36" , x PROJECT LOCATION / ry� < IF— / $ ,r- " 48FLrz I j 113d„ f LP ) --A!== :,=U-_ :8448 I (� t I 48 X — l DIAMETER r— -- 4--1 (� % I L —L FRONT APPROACH SIDE APP CH l I 1 30 X48 / l l 60" T TURN I MIN. LC YJ 60"X59" % 60"X59" 1 1 " M I24" MIN \ L _ CLR FLR CLR FLR M ° 148" X 48" l X 60" � IFRONT APPROACH I � , I FRONT APPROACHI / J 60" j 1 30'X48.. 4 1 /° ——— I DIAMETER o f —1 l CLR r-----� �\ MIN. L - --_ f 1 48" X 48" I ' —— -� 48" X 48" 1 \ / —— -� L 17-1 — -�——-� 71 I FRONT APPROACHI ;, I FRONT APPROACH I 71L / �b �I LOCATION M A P I �'• I( 60" T TURN 30"X�8" 30"X4�" �0"X48" 3i)"X48" I 11 „ M I C�a I I CLR R CLR / U LR FLR CAR I N.T.S. ---1 - L--� j _I I -J - - - ENGINEER: S - - - SIT - - - - - - - - - I ' 24" MIN - - - - - 24" MIN II 71 5 X 60 71 54 X 60 / —+ I l I " „ I i 18" MI 8" MI p I 41 IDE APPROACH I I SIDE APPROAC p p I� L_ — �IJ — — — — — — -- — — — J/ '— — — — — — — — — — J L. K. MCLEAN ASSOCIATES LSCAT�-1/4� OR APPROACH TURNING SPACE Ls XTURE APPROACH ENGINEERING & SURVEYING, D.P.C. CONSULTING ENGINEERS 437 SOUTH COUNTRY RD.,BROOKHAVEN,NEW YORK 11719 = 1'-0" SCALE: 1/4" = 1'-0" 3 CA 1/4" = 1'-0" IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT ENGINEER,TO ALTER IN ANY WAY ANY ITEM ON THESE DRAWINGS, IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ENGINEER IS ALTERED, THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO 42" MIN 12" HIS/HER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY 16-18" : HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC 36n MAX 36"* DESCRIPTION OF THE ALTERATION ON THE DRAWING. ' THE PLANS AND r » r n SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A 39"-'41" 24"* 12" 2-6 1 -6 6n 1n RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. McLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE MIN. MIN. :: SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY Z CLEAR -:: n ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC z = X<=24 FLOOR 17"-25" oo . °° SPACE 0 I I ©L.K. MCLEAN ASSOCIATES ENGINEERING &SURVEYING, D.P.C. A _ z I 30"X48" "' PROJECT: 7"-9" ' _ R o o :. O° R ::. CLR FLR o co co co L.- -- -- CO co R - M o TOWN OF SOUTHOLD "' <.I R SUFFOLK COUNTY, NY 00 ;� � ^ a,_ 19" MAX :::. :::. . :::.:._:.. :::::.:._:::::.::::::.: :::. 48" EXIST. BLDG -: 13.5" 12" MAX 8" MIN 6" MAX 52" NEW BLDG MIN 54" MIN 11" MIN FRONT VIEW SIDE VIEW CLEAR FLOOR SPACE AT URINALS 56" MIN (WALL MOUNTED 17"-25" S O U T H O L D 59" MIN (FLOOR SIDE WALLS REAR WALL OF STANDARD STALLS CLEAR FLOOR SPACE AT TOILETSuNTED KNEE CLEARANCES CLEAR FLOOR SPACE AT RECREATION CENTER * WHERE SPACE PERMITS LAVATORIES AND SINKS BATHROOM CODE SUMMARY HEIGHT A.F.F./LOC CODE SUMMARY HEIGHT A.F.F./LOC CODE SUMMARY HEIGHT A.F.F./LOC RENOVATIONS GRAB BARS 604.5 33" MIN,/36" MAX. TO TOP RIM HEIGHT (TOP OF LAV.) 606.2 33" MIN./36" MAX. TO TOP URINAL RIM 605.2 17" MAX. A.F.F. TOILET LOCATION 604.2 16" MIN./18" MAX. TO CENTERLINE HEIGHT OF KNEE SPACE 606.2 27" MIN. AT FRONT APRON/27" MIN. AT 8" IN FROM FRONT CONTROLS 605.4 44" MAX. A.F.F. TOILET/SEAT 604.4 17" MIN./19" MAX. FRONT LAV TO TRAP 606.2 8" MIN. HORIZONTAL CLEAR FLOOR ACCESS 30" X 48" WHERE ONE WALL/PARTITION IS LESS THAN OR TOILET FLUSH VALVE 604.6 40" MAX., 10" TO WIDE SIDE TOE SPACE UNDER TRAP 606.2 9" MIN. VERTICAL 605.3 EQUAL TO 24" IN DEPTH, OR 36" X 48" WHERE BOTH 970 PECONIC LANE SURFACE MOUNTED TOILET HEIGHT OF DISPENSER'OUTLET TO BE 18" MIN. A.F.F. & 11" CONTROLS 606.2 DECK MOUNT AT 34" MAX. WALLS/PARTITIONS ARE GREATER THAN 24" IN DEPTH. P ECO N I C NY 11958 PAPER DISPENSER 604.7 MIN. FROM BOTTOM OF GRAB BAR. OUTLET TO BE LOCATED CLEAR SPACE 305.5 30" X 48" ' WITHIN AN AREA 24" MIN. - 42" MAX. FROM REAR WALL ISSUES/REVISIONS Description No. Date TOILET DESIGN CRITERIA LAVATORY DESIGN CRITERIA URINAL DESIGN CRITERIA PERMIT RENEWAL: FINISH COLORS 1 01-10-2025 W W z Y SIGNAG n z o J C) 20 MAX �_ Of m a_W � 3 m SIGNAG of O CC t3 W W O W d CC W CD REFACE ' W 1—w LrJ Z ov oF-o oc~i¢i 3 � a ono v Jw wv % Z o F- 45' 18" MIN. = _ - CO w ' �r R LLI Ld d COO W O M. Q X _ - --•----- QQ L�CC R Z = U�J R la] � ----•---- - ... O ----------- ----------------------- - O cn -co Li ¢ 00 R co CENTERED ON = o W 00 � 'L o a o RAISED C TERS „ o`:� oo ® N v o) N m (A) 10 MAX > 20"-25" (A) °° ` z Moo N _ _:_ ___- -- : _ :__ _- _ _- -__ _ _ _- _ _- _- __- �CM STATUS: 00 v Y 130 MIN. CLR, 0 0 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OF GROUND LOCATION OF SIGNS AT DOORS r NOT FOR CONSTRUCTION ni �`FLOOR SPACE r cD FRONT VIEW DRAWING TITLE: 3 . _ mco ICC /ANSI Al 17 . 1 TABLE 603.6 R o MAXIMUM REACH DEPTH 0.5 INCH 2 INCHES 5 INCHES 6 INCHES 9 INCHES 11 INCHES Z z == zt 09 ,� CCESSI BI CITY ---------------------- o MAXIMUM REACH HEIGHT 48 INCHES 46 INCHES 42 INCHES 40 INCHES 36 INCHES 34 INCHES __ o - . :: STANDARDS •o (B) 10" MAX > 10" - 24" (B) SEA �I� Design By: JG FIGURE 308.2.1 FIGURE 308.2.2 FIGURE 308.3.1 FIGURE 308.3.2 Drawn By: JR MEN NOT IN WOMAN NOT IN UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH �} p��,RT Sl rG ' Approved By: CFD N PICTOGRAM �� PICTOGRAM �� Scale: AS NOTED -4 m •� FIELD •0 0� •� FIELD `� 4 Date: JAN. 2025 o '� File No: 21193.000 N d - N � •(;� � � Sheet No. 00 MOUNTING HEIGHTS RESTROOM SIGNS AT DOORS AND GATES � a � G N — 2 CH RANGE DESIGN CRITERIA FULL SIZED PLOT SIZE:24"x 36" PROJECT LOCATION r �, 5 s.,,�,'&,,,,,.,,..dAs„s,Yr,:.,,<>,.,•„ ..�U»»»£,>: 1RON= ..F : '.'G .. ...........gyy3r``� } < ,.::..�.>��Px';.. .. ':./ ..">3d' :.��:.3.3 .,..h ....,.a.,...,.s.F .,:aLLfa»wi,,.sUb�a,3' .0 �sr n „ r , : / t , - 6 ,�i � .rFf� Y £� 1 ¢kf�,,/r Y, : ..:.. ::,." ...... �a.F .Fr .; .i3.:U !/::....J rn ,., ::3 .:::.'.Fa. /• kJ...S :;,' s „ ; ' „�,,, l' <�✓ ;._...,.,,; ...,. ..: ..x ..... ,,, 0.1 , �r,.%scfF .,i .s: .:.:i:. ;; :>;y,a.^;::i £f,,,iih -..,. ;>«s�r,;�3.�.�Yws;«svL ', 3�5 f �^ s J LOCATION M A P Y 10 /G'y N.T.S. , v 'Y!7H/q i,�ii m / ^ry5 .:'7,` Win., 'F �; F rF.�'i �'k5•/ f F �F :SaS fs , J,.,. I. ENGINEER. I 4 n , F J k, 4 1" A I i! y �Ar .�3• .,F....,. j ! ,Yr,tf 1: ,+V s1,.. ..r fr.., s}::::. ,.,�<.:.:.L:Ff,,,.a,.,, ', ,.<, �€ < 5•.<< s.,w. y f, YC:Y, ,..�.. 3•%t'�5. 13'�:' I � i� des: 1'44�,r 1� II '4''', � £sF=' �,.,.,�/JJsr:.Y��/:',!.>. !„Yuj,,, •.¢ f af5 �{3 c / r • HIM:. 'Y/.% / F!'}J ,3 3F.' f!3 'f" >i€k•,. z z;s% €€€i, �\ kf ,sc:% / us l' ,4:/ !///. 14r.' �< :, 3Y 'S%' y .,3,')' � .• '!).£fYT� Y /r .........\ : r a : .i r '+ c s' g•.' K F r 8 „ Y " L. K. McLEAN ASSOCIATES D.P.C. ENGINEERING & SURVEYING, D CONSULTING ENGINEERS 437 SOUTH COUNTRY RD.,BROOKHAVEN,NEW YORK 11719 PHOTO#1 PST PHOTO . PHOTO#4 PHOTO #5 PHOTO #6 PHOTO #7 PHOTO J8 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT ENGINEER, TO ALTER IN ANY WAY ANY ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ENGINEER IS ALTERED,THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO HIS/HER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION ON THE DRAWING. " THE PLANS AND SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. KEY NOTES: 15 McLEAN ASSOCIATES, PC, THESE PLANS AND SPECIFICATIONS WILL BE THE 1 1 15 SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC 1 REMOVE EXISTING TOILETS AND _ __,_ mw==M __-___ _„_,_._�_�_�_ ASSOCIATED PLUMBING TYP. -- - " —— — — --- = m - -- - -----µ -. -------� - _ _.......__........ __...............___ � �,, -- - - __...__ _.� .-_. ! __..._.__._ » ............. : .�„r.....= L......._................... :.................................•„_,,,,•,,,•„••,,,,,•,; ©L.K. McLEAN ASSOCIATES ENGINEERING &SURVEYING, D.P.C. 2 REMOVE EXISTING URINALS AND 16 ��r -1 1 - - -I— — — — — — — —I- - - -{ - - - -I— — — — — — - —I- - - { ; r� _._.._.___._....._ I ASSOCIATED PLUMBING TYP. Ij i �� J�I /�\ 16 i i I I i i 1�1 . 1 11 I' /�.,,.. ! PROJECT: �— I I I I I J L _ REMOVE EXISTING HAND SINK AND VANITY _ _ _ _ _ _ _ - _ I I __ _ _ - _ E OVE EXISTING ( 1 II ~ ! 3 AND ASSOCIATED PLUMBING —— _ _ __ = _= If -1 F II CONCR T FLOOR SLAB — — Y _ _.......__.._...._........_....__.... I y 4 IIF1 II 11 IIF1 I I I 8 TOWN F £ /-� REMOVE EXISTING TOILET PARTITIONS TYP. 9 �\ 11 - - - - - - - - - - - - - - - -- �- - . 4 4 I ...__ Y / .«� 7 O SOUTHOLD �� �1 �\ ' ' ( I I ' JI L J1 � I ! ,n. � SUFFOLK COUNTY, NY E OVE EXISTING REMOVE EXISTING FIXED WALL, AND ASSOCIATED € ———_ _——= I I I I I I lip VIF, TYP. I 1 .w µ:.;f:.:L:..: --µ `'.. ............_............__.._........: :W s PLUMBING. DO NOT DAMAGE STACK VENT PIPING AT ROOF PENETRATION, TYP. -,. 7 I I I I 7 _. 6 \l REMOVE EXISTING CEILING GRID AND TILES = / 3 I I 1 1 I I J . . . 11.L_ _ _ 2 � ;1 i �I - - - -1 - - �. . I Y_--'--- 6 4 _�,� - r - - - - �- , -r - - - - �- - L _ .......::. , SOUTHOLD Imo.. ' I 11 F2 I I F2 11 7 EXISTING LIGHT FIXTURE TO BE REMOVED AND ASSOCIATED BRANCH i �� �/ — 9 F1 F1 «+ 3 ( $ € RECREATION CENTER II CIRCUIT WIRING TO BE REMOVED BACK TO SUBPANEL PP2 �_ _ - LINE F SAWCUT TYP. . . -� I ° I 1 1 I -1 L � ,, BATHROOM SAWCUT AND REMOVE EXISTING SLAB, ADJUST FLOOR oo I 8 DRAIN AND SANITARY PIPE, V.I.F. 5 I I �1 1� I I 1 ° 1 11 I i 1 "'° iy� " '£ 5 € o - - - - - - - - - -I- - - - - -I- - - - - - - - - - a t - €; �' � - # i RENOVATIONS I I -I I� I I I�I LI_ J I w I L £ REMOVE EXISTING FLOOR TILE AND MUD SETTING BED g DOWN T'O EXISTING CONCRETE SLAB, VIF. EXISTING Y,._ FLOOR DRAIN TO REMAIN UNDAMAGED. A _m_..._........_ .........._............_..._. I _._......................... ..... REMOVE EXISTING VCT FLOOR TILE DOWN TO EXISTING I �' `� 6 7 12 6 �" I �' 1 Q CONCRETE SLAB, PROVIDE SAW CUT LINE AGAINST I I € 970 PECONIC LANE OUTSIDE_ EDGE OF NEW WALL BOTTOM TRACK, VIF. —— - - -7— - -- - - - 10 13 QD t_ - - --- - - - - -� 1 PECONIC, NY 11958 SALVAGE' EXISTING CHAIR RAIL CUT AND ALIGN WITH 1 1 NEW WALLS 1 4 11 / ISSUES/REVISIONS 1 2 REMOVE AND REPLACE EXISTING T-STAY 5 Description No. Date SIMILAR 5 IMILAR 13 EXISTING LIGHT SWITCH BACK 30X TO REMAIN; DEMOLITION PLAN REFLECTED CEILING PLAN DEMOLITION CONCRETE FLOOR TRENCHING PLAN PHOTO LOCATION PLAN PERMIT RENEWAL: FINISH COLORS 1 01-10-2025 EXISTING BRANCH CIRCUIT TO REMAIN. a - a 2 - 3 4 a SCALE: 1/4 - 1 -0 SCALE: 1/4 - 1 -0 SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 -0 14 REMOVE EXISTING DOOR FRAME AND HARDWARE.. 15 REMOVE EXISTING BASE BOARD HEATER 16 REMOVE EXISTING TILE FINISH AND GYPSUM BACKER. V.I.F. LEGEND: REMOVE EXISTING TOILET i i r REMOVE EXISTING URINAL �'� 9 � REMOVE EXISTING SINK STATUS: "IRNOT FOR CONSTRUCTION o I ooa DRAWING TITLE: REMOVE EXISTING VANITY .a DEMOLITION AND fa rya REMOVE EXISTING 2X4 LIGHTING E L _-i 0 DEFERENCE PHOTOS 4,, _ REMOVE EXISTING WALL LIGHT a� /I SEA Design By: ]G UI X 1 REMOVE EXISTING SUPPLY AIR DUCT D /y Drawn By: JR ©0��j �� Approved By: CFD o E —_ _ _ EXISTING BASE BOARD HEATER TO BE REMOVED c° Scale: AS NOTED 0 Date: JAN. 2025 Ln n File No: 21193.000 N o o Sheet No. rn men r"Q 07 00 a OF iONa1 4 e r, FULL SIZED PLOT SIZE:24"x 36" CEILING HEIGHT CEILING HEIGHT CEILING HEIGHT CEILING HEIGHTjq ,✓ / ELEV 8'-6" ELEV 8'-6" ELEV 8'-6" ELEV 8'-6" bF ........................................................ ......................... ............ ...........:... .................................................... .............:..................._.............,......, ., .. .., ...._._.............,.............,......... . ....1,..6„ ............ . ...:. : ... _ HOLD CLEAR FROM PROJECT, as .. ..s ..... .s.... . ... WET WALL �. WINDOW FRAME LOCATION V.►.F. TYPO A �i i ......... TA Tq A q N .,. . . I� A TA ,•ns ,. 0 - _ _ y/ • A4 TA1 ;..... <. TA A FIN FLOOR `� ...' TA1 r . ... FlN FLOOR FIN FLOOR FIN FLOOR ELEV 0'-0" ELEV 0'-0" ELEV 0—0 ELEV 0'-0" r vs EN'S INTERIOR ELEVATION MEN'S INTERIOR ELEVATION MEWS INTERIOR ELEVATION MEN'S INTERIOR ELEVATION " CALE: 1/4" = 1'—O" 1 SCALE: 1/4" = 1'—O" 9 SCALE: 1/4" = 1'—O" �SCALE: /4" = 1'-0" �! .g .. .. CEILING HEIGHT ELEV 10'-0" V.I.F. CEILING HEIGHT CEILING HEIGHT CEILING HEIGHT CEILING HEIGHT VESTIBULE CEILING f n n 1 n '.- ELEV 8-6 ELEV 8'- 6 ELEV 8'-6" ELEV 8-6 HEIGHT BEYOND ...," ., ACRYLIC SYMBOLS ELEV 8-0 RAISED E 1 n ......1 �6....,.. LOCATION M A P WET WALL N.T.S. ..... I.................... _ i c6 .....o ?. i A TA _ ... ......_......:......: ...... A ... o ENGINEER . TA A5 TA . . . . . . . . . . . . . . . . . . I TA Tq Cs7. © . . ........:..:. 0 > (TA i I' �r = ...... .. FIN FLOOR TA1 ....;... A4 A6 • a FIN FLOOR FIN FLOOR .. , ....... FIN FLOOR FIN FLOOR ELEV 0—0 ELEV 0—0 ELEV 0—0 ELEV 0—0 ELEV 0'-0 oWOMEN'S INTERIOR ELEVATION WOMEN S INTERIOR ELEVATION WOM ELN'S INTERIOR ELEVATION WOMEN S INTERIOR ELEVATION BATHROOM ENTRANCE ELEVATION r s;CALE: 1/4" = 1'-0" ��SCALE: 1/4" = 1'-0" 5 SCALE: 1/4" = 1'-0" (:j)SCALE: 1/4" = 1'-0" 3 SCALE: 1/4" = 1'-0" L. K. MCLEAN ASSOCIATES ENGINEERING & SURVEYING, D.P.C. CONSULTING ENGINEERS 437 SOUTH COUNTRY RD.,BROOKHAVEN,NEW YORK 11719 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT ENGINEER, TO ALTER IN ANY WAY ANY ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ENGINEER IS ALTERED,THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO HIS/HER ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC 12 1 1 12 KEYNOTES. DESCRIPTION OF THE ALTERATION ON THE DRAWING. ' THE PLANS AND SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. 6'-6�" 9'-2 " MCLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE 1 NEW FLOOR MOUNTED ADA COMPLIANT SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY TOUCHLESS TOILET TYP. ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.MCLEAN ASSOCIATES,PC j NEW WALL HUNG ADA PLIANT - --- - -- -' ---- --- � � - - - K MCLEAN ASSOCIATES ENGINEERING &SURVEY AL F ° ° TOUCHLESS URINAL TYP GI - I I .. ..........._ .... L' .. y'.�a I `"""" NEW FRP TOILET PARTITIONS TYP. PROJECT. ° 10 NEW ADA COMPLIANT TOUCHLESS INTEGRATED HAND SINK TOWN OF S O UTH O LD ,. -_-- (D° _ 16 n— .... ...... ....... ...... .. ...... ........ :.._.. .. ... .......1 ....... ........ .. ...... ....... ..... 16 . 6 . / ° / LINE OF NEW WOOD CHAIR RAIL SUFFOLK OUNTY NY °.: ° : d....: .... ... TO MATCH EXISTING �. NEW HUNG CEILING USE ROCKFON SQUARE LAY IN ° / 6 HYGENIC PLUS MINERAL WOOL OR APPROVED EQUAL .3 �, .. �.. .. ......- ° ` _. ....... AND 15/16 WHITE CEILING GRID ®U T H®�D ° a : / 7 7 NEW LED CEILING LIGHT FIXTURE RECREATION CENTER ......... ........ ...................................... " ° I / \ / 1 8 NEW LED WALL LIGHT FIXTIRE n / / " \ I BATHROOM ELEV=8 —6 1 ELEV=8 —6 LI .. ..., .N d.: 2 o- NEW WHITE SUPPLY CEILING DIFFUSER. CONNECT TO RENOVATIONS �, EXISTING DUCTWORK, VIE �FCt4 j WHITE ALUMINUM BY CARNES OR g USE MODEL SFAB, APPROVED EQUAL CV - F. .; .......................................................................... .................... NEW RECESSED BABY CHANGING STATION I \ / I 6 10 970 PECONIC LANE -1 a / ° GF ° �`v ° a g / g NEW H.M. DOOR FRAME AND HARDWARE PECONIC, NY 11958 9 EF / ° ° ° d O 8 10 ° 6 4 I 1 GFCI cl' 7 1 I 1 NEW 4' BASE BOARD HEATER TO MATCH EXISTING. �` ....................... . \ / USE LANTFIN OR APPROVED EQUAL. V.I.F. ISSUES/REVISIONS �. f S / .. ° 1'-s" ° ° : - ° a : ° M�� \ Description No. Date N, RELOCATE EXISTING LIGHT FIXTURE � 13 PERMIT RENEWAL: FINISH COLORS 1 01 10 2025 4 FCI F2 / - EXISTING FIRST AID KIT. SALVAGE AND REINSTALL 8 F2 8 4 3 ADA SIGNAGE a 15 'T _ _ v A-2 0O 1 PROVIDE NEW 150 CFM CEILING FAN AND WALL ° 1 1 16 SWITCH OCCUPANCY SENSOR: 6 INCH DUCT WITH 1 1 GFCI 44 d Cry° 44�' F / F HOODED WALL CAP DISCHARGE. SEE DETAIL 3/MP-1 *1 j - N. PT -- ---- T Z / BRAILLE - I— —; BAILEE LEGEND: SIGN rj SIGN ELEV 8' 0" _ - NEW GYPSUM PARTITION SEE WALL TYPES I / / A N ............................... ON SHEET A-2 ....... ......... I GYPSUM PIER GYPSUM PIE 14 o . ....... ......... 15 �� ......... I 6 / EXISTING 2'X4' LIGHTING FIXTURE F3 F3 7 EF1 I I / _ INSTALL NEW 2'X4' LIGHTING; r _ r F1 FLAT PANEL - 2'X4'LP-24-L50/835-QS-DIM-UNV 1 5 / 5 IEF1 I IEF1 l INSTALL NEW 6"X24" WALL •J I j it L LIGHTING, / STATUS _ _ / HDR-7 -0 / // / ; / /i// / ® H.E. WILLIAMS ARCHITECTURAL WALL MOUNT - LED - 2 NOT FOR CONSTRUCTION 3 �. — — — — — ———— — — F2 WMA-2-L40/835-AF-DIM-UNV — - - - - — — -- — -- -- - — - - — - — — J ----- - -......... ........_....................... ..._. ._ .. ....._......__ .. _ ER ER F3 INSTALL NEW 4"0 RECESSED LIGHTING; H E WILLIAMS DRAWING TITLE: 1 3 13 4PR-TL-L20/835-DIMI-UNV-LW-OF-WH-N-F1 3 CON STRUCTION � ------ FD EXISTING FLOOR DRAIN; ADJUST TO MEET NEW _ ..._..... .. ..__..........................._.. .. .......... . .... ®E FLOOR TILE FINISHES. o PLANS PROPOSED LIGHT SWITCH WITH VACANCY/OCCUPANCY SENSOR AND ADJUSTABLE TIMING o SEAL Design By: JG L FCIRECEPTACLE Drawn By: JR DUPLEX GFCI .........._.......__ ......................._................................... ............._..........._....... .... _ DUPLEX RECEPTACLE ON NEW DEDICATED GFCI R qp G N q8E Approved By: CFD CIRCUIT BACK TO SUBPANEL IN MAIN ELECTRIC � ' s'� '�• ;- 0 CONSTRUCTION PLAN 9 PROPOSED RCP T CLOSET <^�, Scale: JA NOTED m Date: JAN. 2025 Ln 1 2 THERMOSTAT-REPLACE EXISTING WITH NEW File No: 21193.000 N o SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" v/' N PROPOSE FAN SWITCH WITH OCCUPANCY SENSOR 0�1 �� Sheet No. w� F AND ADJUSTABLE TIMING p�, 9� re".��` O ,-H F it m N r, a FULL SIZED PLOT SIZE:24"x 36" n TOILET ACCESSORIES PROTECT SEE INTERIOR ELEVATIONS LOCATION , WOOD STUD INSERT WOOD STUD INSERT # ACCESSORY MANUF. / MODEL # FINISH REMARKS " :•. TAt SURFACE MOUNTED BOBRICK B-4221 STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. / EXIST. ASS SEAT-COVER DISPENSER �q / NO 8 X 1-1/2" L EXIST.ROOF ASEMBLY STAINLESS 8 X 1-1/E L STAINLESS STEEL FASTENER, TA2 H.C. MIRROR BOBRICK B-165 STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. ` STAINLESS STEEL FASTENER, AND CUP WASHER \\ // // O _ AND CUP WASHER \ / / ' n n \ \ / / CEILING HEIGHT PAPER TOWEL DISPENSER ., °°`° ` ' ,.. 3-1/2" X3-1/2" STAINLESS 3-1/2 X3-1/2 STAINLESS \ \ / p INGVENT V.I.F. TA3 & WASTE RECEPTACLE BOBRICK B-369 STAINLESS STEEL RECESSED - SEE INT. ELEVS. STEEL CORNER GUARD WITH \ \ / IE STEEL CORNER GUARD WITH STANDARD DRILLING 6" O.C. \ \ / / • I I FASTEN TOP TRACK TA4 TOILET TISSUE HOLDER BOBRICK B-2888 STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. STANDARD DRILLING 6" O.C. AND 3 INCHES FROM EDGE \\ \\ // / I I TO EXIST CEILING CORNER AND 3 INCHES FROM EDGE ENDWALL \\ I I // 2X4 BRACING TO ROOF TA5 GRAB BARS BOBRICK B-6806 STAINLESS STEEL LENGTH 30 & 18 - SEE INT. ELEVS. STRUCTURE 48 O.C.,VIF SURFACE MOUNTED SANITARY ` I I I TA6 BOBRICK B-270 STAINLESS STEEL SURFACE MOUNTED - SEE INT. ELEVS. • ` NAPKIN DISPOSAL > 5/8" GYP. WALL MOUNTED - MOUNT 48" ON INSIDE TOILET WOOD STUD INSERT I I ( I TA7 HEAVY-DUTY CLOTHES HOOK BOBRICK B-211 NICKEL-PLATED A . BACK TO BACK STUD I I STALL DOORS, TYP. 5/8" GYP. 2" CEILING HEIGHT I I RECESSED BABY CHANGING w ATCH EXIST VI _ TA8 KOALA KARE KB311-SSRE STAINLESS STEEL RECESSED - SEE INT. ELEVS. BOTTOM TRACK I I ELEV:9'-0" I I ELEVCEILINS OHEIGHT STATION R LOCATION M A P TOILET FIXTURES TOILET ROOM TOILET ROOM HIGH BAY PRIVACY VESTIBULE SEE PROPOSED FLOOR PLAN N.T.S. � 5 6/8"MOLD AND MOISTURE , RESISTANT TYPE-X GYPSUM # FIXTURE MANUF. / MODEL # FINISH REMARKS ENGINEER: N BOARD BOTH SIDES R STEEL BACKER PLATE AT ALL TF1 WALL MOUNT SINK BRADLEY VERGE - LVQ-SERIES BRUSHED STAINLESS WALL-HUNG LAVATORY; ADA COMPLIANT 1i" VIF 1 WALL HUNG ACCESSORIES TF2 TOUCHLESS SINK FAUCET BY BRADLEY SATIN STAINLESS WALL-HUNG LAVATORY, AUTOMATIC A.C. R ADA COMPLIANT OPERATION, 16"O MTL.STUD 20 GA, 3-518"MTL.STUD 18 GA. TF2A TOUCHLESS SINK FAUCET BY BRADLEY N/A BELOW SINK AC POWER SUPPLY PER 16"OC TYP. 12"OC TYP POWER SUPPLY MANUFACTURER REQUIREMENTS J01 JAMB H01 HEAD Of TF3 SINK P-TRAP BY BRADLEY POLISHED CHROME INCLUDES CLEAN-OUT PLUG AND BRUSHED STAINLESS STEEL REMOVABLE APRON URINAL SLOAN VITREOUS CHINA WHITE WALL HUNG; REINFORCE WALL HUNG URINAL PER L. K. McLEAN ASSOCIATES ( 5/8"GLASS MAT WATER , I ( WASHDOWN URINAL SU-1009 MANUFACTURE INSTRUCTIONS. LIGHT GAGE FRAMING AND DOOR BUCK DETAILS • I I : RESISTANT GYPSUM BACKER 5/8"TYPE-XGYPSUM BOARD ENGINEERING & SURVEYING, D.P.C. BOARD BEHIND TILE,TYP. I ( BOTH SIDES;LEVEL FOUR TF5 URINAL FLUSH VALVE SLOAN ROYAL 186 ESS STAINLESS STEEL ADA COMPLIANT, AC POWER SUPPLY TOUCHESS CONSULTING ENGINEERS 437 SOUTH COUNTRY RD.,BROOKHAVEN,NEW YORK 11719 FINISH. OPERATION 3/8"CERAMIC SUBWAY WALL I I TF6 URINAL STRAINER KOHLER NO-K-9183 STAINLESS STEEL BEEHIVE GRATE FOR CAULKING 2" PIPE. NE OF SAW CUT AT EXIST. WALL NEW WOOD CHAIR RAIL TO / I I TILE I I 1F7 TOILET BOWL KOHLER HIGHCLJFF ULTRA TOP WHITE FLOOR MOUNTED ADA COMPLIANT IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE MATCH EXISTING O SPUD FLUSHOMETER BOWL DIRECTION OF A LICENSED ARCHITECT ENGINEER,TO ALTER IN ANY WAY ANY 2X6 SUBWAY TILE TOP / I I K-96057-SS ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ENGINEER IS ALTERED,THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO BULL NOSE / I I HIS/HER ITEM THEIR SEAL AND THE NOTATION 'ALTERED BY" FOLLOWED BY (I I O KOHLER HIGHCLIFF ULTRA TOP Y I TF8 TOILET BOWL: WHITE FLOOR MOUNTED NON-ADA COMPLIANT HISMER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC SPUD FLUSHOMETER BOWL DESCRIPTION OF THE ALTERATION ON THE DRAWING. THE PLANS AND 5-96057 SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A n , ELECTRIC J=BOX TYP. / I n ( RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. NEW WALLS: E MOLD AND ALIGN TO FACE OF GYPSUM 6 I I ADA COMPLIANT; AC POWER SUPPLY TOUCHLESS McLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE MOISTURE RESISTANT / ' " 3�" TF8.1 TOILET BOWL FLUSHOMETER SLOAN ROYAL 111 ESS STAINLESS STEEL SUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY GYPSUM BOARD j I 7 I I din I OPERATION ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC / GYPSUM WALL FINISH / I " I ''T� TF9 TOILET BOWL SEAT KOHLER ELONGATED WHITE OPEN FRONT SEAT WITHOUT LID 8 CONTINUOUS MTL.RUNNER COMMERCIAL HEAVY DUTY SEAT 0 SECURED TO EXIST FLOOR ( I 6"VINYL WALL BASE, NO-K-4731-CA C L.K. McLEAN ASSOCIATES ENGINEERING &SURVEYING, D.P.C. HIGH STRENGTH ACRYLIC I I TO MATCH EXISTING POLYMER TILE ADHESf✓E / I I I I CONTINUOUS MTL.RUNNER PROJECT: / MOUNT ACCESSORY ON / I I I SECURED TO EXIST FLOOR TOILET P A R TI TI O N /SCREEN /COM P A R TM E N TS // SHIMS AND PROVIDE BACKER ROD AND / . I I SEALANT BOTH SIDES I I ' / SEALANT AT ALL GAPS �� : i I SEALANT BOTH SIDES # COMPARTMENT MANUF. / MODEL # FINISH REMARKS TOWN OF S O UTH O LD WHITE LATICRETE SPECTRA LOCK / / f � :.o TP1 TOILET PARTITION GENERAL PARTITIONS D381-60 FASHION GREY FLOOR MOUNTED OVERHEAD BRACED, SUFFOLK COUNTY, NY / EXISTING CONCRETE FLOOR O SERIES 40 FRP PARTITION SURFACE MOUNTED GROUT, OR APPROVED EQUAL / / EXISTING CONCRETE FLOOR WALL TILE / / WALL TYPE TP2 URINAL SCREEN GENERAL PARTITIONS D381-60 FASHION GREY WALL MOUNTED 12 INCHES ABOVE WALL TYPE SERIES 40 FRP SCREEN FINISH FLOOR, CONTIUOUS CLIP / SCALE:NTS 2 S O U T H O L D SCALE:NTS FINISH SCHEDULE EXIST. STUD WALLS: FACE EXIST. / TOILET ROOM ACCESSORY / RECREATION �����t I®� STUDS WITH MOLD AND MOISTURE RESISTANT CLASS MATT GYPSUM / � j # ASSEMBLY MANUF. / MODEL # FINISH REMARKS BATHROOM BOARD. / + / CT-1 EXIST CONCRETE FLOOR TRAFFIC MASTER VIGO GRI (GREY) INCH X 24 INCH HOME APPROVED EQUAL �� O�ATI®�s ce) I 0 G D GROU GREY 0 - 0 CT-1 GYP WALL WAINSCOTT DAL TILE CLASSIC COLOR WHEEL 3 INCH X 6 INCH SUBWAY WWW.DALTILE.COM OR APPROVED j TILE COLOR (0190); AR11C WHITE WITH GREY GROUT EQUAL / ELECTRIC J-BOX TYP. / CT-2 GYP WALL WET WALL DAL TILE CLASSIC COLOR WHEEL 3 INCH X 6 INCH SUBWAY TILE WWW.DALTILE.COM OR APPROVED COLOR (0169); WATERFALL WITH GRAY GROUT QUAIL 970 PECONIC LANE / ALIGN TO FACE OF TILE / PT-1 NEW/EXIST GYP WALL P SUBMIT MANUFACTURER STANDARD PE N APPROVED EQUAL COLORS FOR OWNER APPROVAL CO IC, NY 11958 / 15-1/4' 15 1/4' PT-2 HM DOORS AND FRAMES; WOOD SHERWIN WILLIAMS OR SEMI-GLOSS SUBMIT MANUFACTURER STANDARD / 20" MILLWORK APPROVED EQUAL COLORS FOR OWNER APPROVAL / ACCESSORY WALL INTERFACE ISSUES/REVISIONS Description N / PAINT SCHEDULE p o Date / WET WALL TILE PT-1, NEW GYPSUM, TOILET ROOM. PERMIT RENEWAL: FINISH COLORS 1 01-10-2025 3X6 SUBWAY TILE STACK BOND; / PRIMER: HIGH PERFORMANCE FINISH PRIMER ProMar 200 ZERO VOC LATEX PRIMER B28W2600 11 COURSES AT WAINSCOTT " 82" 58" 48' Is T COAT: PRO INDUSTRIAL PRE CATALYZED WATER BASED EPDXY GLOSS, 673-300 SERIES. 27 COURSES AT WET WALL / 2X6 WAINSCOTT 48" 47" 2ND COAT: PRO INDUSTRIAL PRE CATALYZED WATER BASED EPDXY GLOSS, B73-300 SERIES. / TOP BULL NOSE / 60" PT-2, MISCELLANEOUS METALS, DOORS AND FRAMES. 4X6 SANITARY TILE BASE PRIMER: SEMI-GLOSS FINISH PRIMER; PRO INDUSTRIAL PRO CRYL UNIVERSAL PRIMER B66-310 SERIES. — FLOOR TILE ON / IST COAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS, B66-650 SERIES. MEDIUM SETTING BED / 2ND COAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS, B66-650 SERIES. / 18 12" 1 S" 12" 2 1/2" TURN UP WATERPROOF MEMBRANE / INSIDE CORNER I AT WALLS TYPICAL FRONT ELEVATION SIDE ELEVATION WALL HUNG URINAL SCREEN WITH CONTINUOUS FLANGE e a _ — / A 2 CERAMIC TILE DETAILS WALL TOILET PARTITION ELEVATIONS ` ff SCALE: 3" = 1'-0" � SCALE: NTS STATUS: 3 GREY LATICRETE SPECTRALOCK EXISTING METAL DOOR NOT FOR CONSTRUCTION GROUT, OR APPROVED EQUAL v N 12 X 24 FLOOR TILE SEE FINISH SCHEDULE PROFILE OF EXISTING DRAWING TITLE: Q RAISE EXISTING NEW FLOOR TILE rn POLYMER MODIFIED HIGH MEDIUM BEAD FLOOR DRAIN, VIF FLOOR FINISH AND 3 STRENGTH LARGE TILE ADHESIVE; I THRESHOLD TO BE REMOVED. BEIGE MARBLE USE 4-XLT RAPID BY LATICRETE OR APPROVED EQUAL — THRESHOLD REMOVE EXISTING PENNY TILE; DETAILS E "¶" I p v ELASTOMERIC SEALANT -I- AND DOOR THRESHOLD u I �J f6 LIQUID RUBBER MEMBRANE; USE HYDRO BAN AT GAP "' ELASTOMERIC SEALANT EXISTING SAW AND SCHEDULES �I� REMOVE EXISTING MUD SETTING BED AT GAP NEW OLD o DS -663-1021 BY LATICRETE OR APPROVED EQUAL 1 LINE OF SAW CUT, �I — — — — — �I � �� VIF CONCRETE ON-GROUND EXISTING CONCRETE ON-GROUND r — _ �—I�- 4 - Imo- EXPOSE SURFACE AS PROPER SUBSTRATE FOR NEW TILE SEA E; Design By: JG o = — — — — — — - _ = .. . _ SIN Drawn By: JR 00 . .. m � � � � � .. � � .. � � � � � � � � � � .. � � .. s � .. � � � � � � I .. � � � .. � .. � � `�:_.� r: •_- �. r .-.._ .. : .. �o�� A' Sl'l �� Approved By: CFD Scale: AS Q Q �Id �I� a M a Q� 4 Date JANN02025D No Q- Q > a d � r File No: 21193.000 r Sheet No. 00-4 CERAMIC TILE DETAILS FLOOR 0 � 3 tea` A ® 2 r, a SCALE: 6" = l'-0" -�- FULL SIZED PLOT SIZE:24"x 36" EXIST. ROOF ASSEMBLY, V.I.F. PR03ECT DIST WALL CORE 6-1/2 INCH BUM WATER STAINLESS STEEL CAULK ALL JOINTS LOCATION � BUM WATER PREFABRICATED DIAMETER ROUND HOLE CUTOFF TAPE COVER PLATE. SCREW IN FINAL ASSEMBLY UNISTRUT TRAPEZE; CONNECT TO CENTERED ON PANEL CUTOFF TAPE HOODED WALL CAP WITH CORROSION USE SHEET METAL SCREWS: '•, MINIMUM 3 PURUNS TYPICAL PACK ALL VOIDS WITH MINERAL RESISTANT SHEET WITH SELF SEALING WOOL INSULATION. METAL SCREWS AND WASHERS r0 THREADED ROD RUBBER WASHERS EXIST. METAL PANEL WALL ASSEMBLY, CORE CUT ROUND HOLE CENTERED BETWEEN PANEL SEAMS. V.I.F. LOCATION OF ALL ABOVE CEILING PURUNS, PRIOR TO CUTTING f MINERAL WOOL INSULATION AT ANNULUS TYPICAL + - HOODED WALL CAP. FASTEN TO METAL PANEL PER. , MANUFACTURER INSTRUCTIONS. SEAL BACK SIDE OF CAP FLANGE TO AGAINST METAL PANEL WITH NON—SKINNING BUM TAPE. SEE WALL PENETRATION DETAIL 6 INCH DIAMETER ROUND DUCT. �' LOW PROFILE, DIRECT DRIVE CEILING EXHAUST FAN USE: GREENHECK NO.SP—B150—QD, 92-160 CFM 6 OR APPROVED EQUAL + ;� n y' LOCATION M A P VIBRATION ISOLATOR • N.T.S. HUNG CEILING ENGINEER: EXHAUST FAN GRILLE, COLOR TO WALL PENETRATION D ETA I L MATCH CEILING I CEILING EXHAUST FAN L. K. McLEAN ASSOCIATES 3 N.T.S. ENGINEERING & SURVEYING, D.P.C. CONSULTING ENGINEERS 437 SOUTH COUNTRY RD.,BROOKHAVEN,NEW YORK 11719 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT ENGINEER,TO ALTER IN ANY WAY ANY ROOF 4' VENT THROUGH ROOF, VIF ITEM ON THESE DRAWINGS. IF AN ITEM BEARING THE SEAL OF AN ARCHITECT/ ENGINEER IS ALTERED,THE ALTERING ARCHITECT\ENGINEER SHALL AFFIX TO HIS/HER ITEM THEIR SEAL AND THE NOTATION 'ALTERED BY' FOLLOWED BY HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION ON THE DRAWING. ' THE PLANS AND SPECIFICATIONS HEREIN ARE INTENDED FOR THE SUBJECT PROJECT ONLY AS A RESULT OF CONTRACTUAL NEGOTIATIONS BETWEEN THE OWNER AND L.K. EXISTING SANITARY RISER EXISTING SANITARY VENT McLEAN ASSOCIATES, PC. THESE PLANS AND SPECIFICATIONS WILL BE THE TSUBJECT OF A COPYRIGHT PETITION AND MAY NOT BE REVISED OR REUSED BY ANYONE WITHOUT WRITTEN AUTHORITY OF L.K.McLEAN ASSOCIATES,PC ©L.K. MCLEAN ASSOCIATES ENGINEERING &SURVEYING, D.P.C. PIPE PROJECT: PREFABRICATED RUBBER FLASHING BOOT AND STAINLESS STEEL HOSE CLAMP TOWN OF SOUTHOLD UR UR ROOF PANEL VIF SUFFOLK COUNTY, NY VERIFY WITH SPECIFICATION VERIFY WITH SPECIFICATION LAV LAV m1 o; FIELD CUT HOLE 1' MIN. LARGER THAN PIPE. �` o o LOCATE ALL PIPE IN THE BROAD FLAT OF S O U T H O L D WC WC WC WC �� _ / PANEL; ALTERNATE VIF EXISTING HOLE SCREW WITH CORROSION RESISTANT SHEET RECREATION CENTER FLOOR METAL SCREWS AND RUBBER WASHERS FDS FD BATHROOM ATHROOM 4" 4" 4" 4" RENOVATIONS 2" 2" 2" '. 2" SUBSTRATE OPENING MUST BE 1" LARGER ' 3" 3" THAN BASE OF ROOF JACK; ALTERANT VIF EXISTING HOLE ROOF PENETRATION DETAIL 970 PECONIC LANE 4" 4" PECONIC, NY 11958 CONNECT TO EXISTING WASTE LINE. ' ISSUES/REVISIONS MODIFY AS REQUIRED Description No. Date PERMIT RENEWAL: FINISH COLORS 1 01-10-2025 0`3"ANITARY RISER DIAGRAM 2 N.T.S. ROOF CONNECT TO EXISTING WATER TO EXISTING PIPING AND LINES V.I.F. 11VI TIMLIN HEATER iT_ c cw cw—cw F cw—cw�cw—cw c —cw—cw cw�cw cw cF cw—cw cw—cw— W„�F cw cw L W-HW HW- -HW-HA-HW-HW�-HW-HW W- W-HW TW � HW-HW HW-H� HW-HW �HW- -HW �I{ 3 3 " �n U " 'T U U U � YIF TP TP 1 U U U U U U WHA I I WHA j j j j WHA j WHA I WHA WHA WHA WHA WHA WHA STATUS: LIST OF ABBREVIATIONS " _ ," in ( in in I" in _ , I" in 1" 1" NOT FOR CONSTRUCTION ' ' TP = TRAP PRIMER v U U WC = WATER CLOSET DRAWING TITLE: a i NOTES: SHWR = SHOWER 3 I I I FD = FLOOR DRAIN PLUMBING RISER VI �1 1. PROVIDE INSULATION AT ALL DOMESTIC HOT WATER PIPING UR = URINAL �` E U 3 " 3 3 3 2. PROVIDE INSULATION AND VAPOR BARRIER AT ALL COLD WATER SUPPLY HWS = HAND WASHING STATION DIAGRAMS AND U U U U PIPING �I 0 3. PROTECT ALL INSULATED PIPING WITH PVC JACKETING LAV = LAVATORY I I I �1 G I� DF = DRINKING FOUNTAIN/BOTTLE FILLER o HB = HOSE BIB Design E:SEA 9 By: JG WHA = WATER HAMMER ARRESTOR L_ LAV WC UR UR LAV WC WC WC .`'Q,� f%y Drawn By: JR m4� u FLOOR 00 R A. Sl dry', Approved By: CFD N L Scale: AS NOTED FD FD Date: JAN. 2025 o File No: 21193.000 rq M � N7 / Sheet No. DOo VN. OMESTIC WATER RISER DIAGRAM o GS. SIONa .� IVI I � a FULL SIZED PLOT SIZE:24"x 36"