Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50934-Z
of Soaryo`o Town of Southold * * P.O. Box 1179 �0 53095 Main Rd UNr` Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45794 Date: 11/24/2024 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 835 Strohson Rd Cutchogue,NY 11935 Sec/Block/Lot: 103.-10-8 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 05/20/2024 Pursuant to which Building Permit No. 50934 and dated: 07/11/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built" garage conversion to den with fireplace and HVAC to existing single family dwelling as applied for. The certificate is issued to: Geertrui Van De Heyning,Alan Davies Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50934 10/23/2024 PLUMBERS CERTIFICATION: ,--� 4,vl"v wavn A ho ' ed Signatur �o�SUFFat�.co TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o • SOUTHOLD, NY s o� , BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50934 Date: 7/11/2024 Permission is hereby-granted to: Van De Heyning, Geertrui 143 St Felix St Apt 1 Brooklyn, NY 11217 To: Legalize as-built garage converted to den and installed HVAC at existing single family dwelling as applied for. Additional certification may be required. At premises located at: 835 Strohson Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 103.-10-8 Pursuant to application dated 5/20/2024 and approved by the Building Inspector. To expire on 1/1012026. Fees: AS BUILT-SINGLE FAMILY ADDITION/ALTERATION $600.00 CO-ALTERATION TO DWELLING $100.00 Total: $700.00 Building Inspector o��oF so�ryol h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 Oly� Nam sean.devlinitown.southold.ny.us COUNTY, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Geertrui Van De Heyning Address: 835 Strohson Rd city:Cutchogue st: NY zip: 11935 Building Permit#: 50934 section: 103 Block: 10 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 5 Ceiling Fixtures Exhaust Fan 1 Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower 1 Range Recpt Ceiling Fan 1 Combo Smoke/CO 1 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " Garage Converted to Den & HVAC Inspector Signature: Date: October 23, 2024 Copy # TOWN. O F SOUTHOLD BUILDING DEPT. y , �o,rm��'�� . 631-765-1802 I-NSPECTION [ ] FOUNDATION-1 ST/ REBAR [ ] ROUGH PLBG. [ ]. FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE 1 CHIMNEY [ ] FIRE'SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: of - Wei f o DATE /2 Zk INSPECTOR ho�aOF SO(/Th°� * # -TOWN OF SOUTHOLD BUILDING DEPT. o 631-765-1802 [NSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] 'FIRE SAFETY INSPECTION, [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ]. CODE VIOLATION /[ ]_PRE C/O [ ] RENTAL REMARKS: 1� �• DATE INSPECTOR Jill �ll { . po; Fe { j .W poop S�,E•U (�}t; a .o Pan i^ I'° c, N ,� - - - - - COUn r v �i t t v k: ll a1 � i lip Ir ,x ,R gal i-fit ,f� n1 \aF d Its cAS trz _ — — . 36 — 23 32Mori — a 1 s _ _ -qw 3s CD Q ��_ •© ---- o F . 4 , N o _ kk ell N i t t z _ { 1 � 1{a■{ (35 2 r �A t y( p� ■ �ul�lgYN SL ON +rJ►►1rrm -L a 16 ()3 asnS ew aa .C, MOAV-o -A OPZWt w 0 H JdAf a WOHa : /L wH!© QT+ } C4 I C14 ..�... • ` '6 • _ .�-- _ ��� �'� �- FIELD INSPECTION.REPORT DATE— COMMENTS FOUNDATION (1ST) -------------------------------------- - ---------- FOUNDATION (2ND) CIO ... ........... O ----------- ROUGH FRAMING& ------ PLUMBrNG INSULATION PER N. Y. STATE ENERGY CODE -------- - ------- FINAL ADDITIONAL COMMENTS C-� 01 DD 061- 5-Lj- 0 ........... rn .......--------- ----------- =o'%gf Fat/fcoGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT y a Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�o• �a Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.g_ov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �j/� 2 2 0 2024 PERMIT NO. `� v CJ Building Inspector: MAY Applications and forms must be filled out in their entirety.Incomplete Building DeParI T',Ont applications will not be accepted. Where the Applicant is not the owner,an ' avu arOttiYec�od Owner's Authorization form(Page 2)shall be completed. Date:05/08/2024 OWNER(S)OF PROPERTY: yName:Geertrui Van de Hey_ning_& Alan-_Davies scTM#s000m Project^Address:835 Strohson Road, Cutchogue,_NY 11935 Phone#_ 203 895-2217 Email:famvandeheynng@gmail.com Mailing Address: Jt43 .. ST- �FEC,. CONTACT PERSON: Name:John McNeill - McNeill Architecture Mailing Address:321 Riverside Drive, :Riverhead NY 11901 Phone#: 516 376-8594 Email:'Ohn mcnelllarchitecture.com - - - - --- --- -- DESIGN PROFESSIONAL INFORMATION: Name:John McNeill - McNeill Architecture Mailing Address:321 Riverside Drive, Riverhead, NY 11901 - Phone#: 516 376-8594 Email:'ohn mcnelllarchitecture.com - --- - -�-- - - - - - ----. ----- TT- - -J-- h-_@_- ---- - CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: D Other Legalization of garage converted to den,add Central Air Conditioning Unit $12000 Will the lot be re-graded? ❑Yes ENO Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential this property? CIYes ®No IF YES, PROVIDE A COPY. B Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations orfor removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are punishable as a Gass A misdemeanor pursuant to Section 21CAS of the New York State Penal Law. Application Submitted By tint name):John McNeill BAuthorized Agent ❑Owner Signature of Applicant: Date: DS --),( 2 -1 STATE OF NEW YORK) SS: COUNTY OF ) John McNeill, R.A. being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)heisthe Agent / Architect (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this -,-",.application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of MoLt, .20 2 4 Notary Publi SUSAN T.YOUNG NOTARY PUBLIC,STATE OF NEW YORK PROPERTY'C1WNER_AUT�IORIZATioN_' _ Registration No.01Y06209293 (Where the applicant is not the owner) Qualified in Suffolk County Commission Expires 07127/02 I,. Geertrui• Van,de Heyning residing at .jtl '?i' (�hCOKL\f1O Ny 1 121 l do hereby authorize John McNeill to apply on r y,.behalf to t e, o n of buthold Building Department for approval as described herein. )a y Owner' Sig ru Date ,X Print Owner's Name 2 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential this property? Dyes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):John McNeill BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) John McNeill, R.A. being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent / Architect (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will.be performed in the manner set forth in the application file therewith. Sworn before me this day of ,20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Geertrui Van de Heyning residing at 1y,S s-17 'FEL_I V Bkcxol<w, j UV 112.11 do hereby authorize John McNeill to apply on y b of to t e n of outhold Building Department for approval as described herein. �Ll Owner' Sig to Date 61 I-Ic w l ym) r-)g >-lf YAA)6` Print Owner's Name 2 ��SvFFDI,��o BUILDING DEPARTMENT- Electrical Inspector ��O Gyr► TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO,Box 1179 co '* Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh(aD-southoldtownny.gov— seand(c-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Geertrui Van De heyning &Alan Davies Address: 835 Strohson Road, Cutchogue, NY 11935 Cross Street: Baldwin Place Phone No.: (203)895-2217 Bldg.Permit#: 5'QG��j� email: famvandeheyning@gmail.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Legalization of garage converted to den. Add Central Air Conditioning Unit Square Footage: 1270 Circle All That Apply: Is job ready for inspection?: R1 YES ❑ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑ YES ❑� NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION �f saaf �t,� BUILDING DEPARTMENT-Electrical Inspector 6YAP } 10' ✓�-; TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 � ,r ��4;Y Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh a sautholdtownny aov-- seand at'-southoldtownnv qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Geertrui Van De heyning &Alan Davies Address: 835 Strohson Road, Cutchogue, NY 11935 Cross Street: Baldwin Place Phone No.: (203)895-2217 BIdg.Permit#: 5_C)q 3 email: famvandeheyning@gmaii.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Legalization of garage converted to den. Add Central Air Conditioning Unit Square Footage: 270 Circle All That Apply: Is job ready for inspection?: 0 YES O NO O Rough In R1 Final Do you need a Temp Certificate?: YES R]NO issued On Temp Information: (All information required) Service Size Ph 03 Ph Size: A #Meters Old Meter# ]New Service[]Fire Reconnect[]Flood ReconnectOService Reconnect OUndergroundOOverhead # Underground Laterals Ell 2 f7 H Frame Pole Work done on Service? MY nN Additional Information: PAYMENT DUE WITH APPLICATION svv 0 C �� ail StFF Oil( BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD E a Town Hall An: - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 r iamesh@southoldtownny.gov - seand&southoldtownny.g v APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Geertrui Van De heyning &Alan Davies Address: .835 Strohson Road, Cutchogue, NY 11935 Cross Street: Baldwin Place Phone No.: (203)895-2217 BIdg.Permit#: 5 Oq-3+ email: famvandeheyning@gmail.com Tax Map District: 1000 Section: Block: o Lot: Z3 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Legalization of garage converted to den. Add Central Air Conditioning Unit Square Footage: 1270 Circle All That Apply: Is job ready for inspection?: R1 YES ❑ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: 0 YES FV-] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame M Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ca. � t) �� PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans 1 Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo 1 Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments Horton, LisaMarie From: Fam VDH <famvandeheyning@gmail.com> Sent: Tuesday, October 22, 2024 11:29 AM To: Horton, LisaMarie Cc: alan davies Subject: Re: Permission to enter the house LisaMarie, v $ eultin ermissio to Bite ©u ©usean $�SStrolson' Ro clinCutclogue�onOctober2 2024, in order to finalize the electrical inspec ion. Please ask him to cal Alan.2'©3 218 00'S s7or Fam 203 8952217 who he is done and kindly ask him to put the key back in it's assigned hiding spot, Thank you very much for all your help, Fam On Oct 22, 2024, at 11:01 AM, Horton, LisaMarie<lisamarieh@southoldtownny.gov>wrote: Z&aMarie.Morton Town of Southold Building Department Annex Building 54375 Main Road Southold,NY 11971 (631) 765-1802 1 Air Indoor Coils • �� 0 RCF Series 1 1 The new degree of comfort!' . Cased/Uncased Coils For - Gas,And Oil Furnaces RCF- Series featuring Industry Standard R-410A a Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] c@11 LISTED • f (W Metering Device Shown) • Rheem®Indoor Furnace cased coils and replacement • Approved for system application with variety of Rheem uncased coils are designed for use with Rheem outdoor outdoor units. units and are available for vertical upflow or downflow, and . Condensate drain pan is constructed of high grade,heat horizontal left or horizontal right airflow.When matched resistant,corrosion free thermal-set material. with Rheem outdoor units,the coils provide a nominal capacity range from 18,000 BTU/HR[5.24 kW]to 60,000 • Compatible with Germicidal Light System (UV resistant) BTU/HR[17.6 kW]. • Bi-Directional airflow eliminates the need to switch any • Constructed of aluminum fins bonded to internally grooved internal components from horizontal left to right. aluminum tubing. 9 Unique drain pan design maximizes application flexibility • Coils are tested at the factory with an extensive refrigerant and condensate removal. leak check. • N-Coil design maximizes performance and minimizes height • Coils have copper sweat refrigerant connections. required at installation. • Feature two sets of 3/4" [14.1 mm]N.P.T. Condensate drain • Coils are AHRI certified for system application with a variety connections for ease of connection. of Rheem outdoor units. • Chatleff metering device connections, at inlet and outlet of TXV or EEV and equalizer connections(TXV only). INTEGRATED HOME COMFORT FORM NO.C11-224 REV.5 Table of Contents �i RCF Series TABLE OF CONTENTS Model Number Identification............................................................................3 Coil Specifications ......................................................................................4-5 Coil Dimensions and Weights........................................................................6-7 Accessories ................................................................................................8-9 LimitedWarranty ..........................................................................................10 INTEGRATED HOME • •- Air Model I.D. 0 RCF Series Model Number Identification R C F 24 17 S T A M U A Option Code *TBD Minor Series** TXV MODELS AVAILABLE Component Change RGF2414STAMCA RGF2414STAVUA Cost Reduction Non-performance Changes RCF2417STAMCA RCF2417STAVUA Casing RCF2417MTAMCA RCF2417MTAVUA U =Uncased RCF2417HTAMCA ROF2417HTAVUA C=Cased Orientation RCF2421MTAMCA RCF2421MTAVUA M=Multipoise RCF2421HTAMCA RCF2421HTAVUA V=Vertical only/convertible RCF3617STAMCA RCF3617STAVUA H =Ded.Horizontal Only Major Series* RCF3621STAMCA RCF3621STAVUA Feature Set Change *RCF3621MTAMCA *RCF3621MTAVUA Performance Change RCF3621HTAMCA RCF3621HTAVUA Metering Device RCF3624MTAMCA RCF3624MTAVUA T =TEV E =EEV RCF3624HTAMCA RCF3624HTAVUA P =Piston RCF4821STAMCA ROF4821STAVUA Efficiency *RCF4821MTAMCA *RCF4821MTAVUA S =Standard Efficiency M=Mid.Efficiency RCF4824STAMCA RCF4824STAVUA H =High Efficiency RCF4824HTAMCA RCF4824HTAVUA U=Ultra Efficiency *RCF6021S1'AMCA *RCF6021STAVUA Width 14=14"[356 mm] *RCF6021MTAMCA *RCF6021MTAVUA 17=17.5"[431.8 mm] RCF6024STAMCA RCF6024STAVUA 21=21"[533.4 mm]24=24.5"[609.6 mm] RGF6024HTAMCA RCF6024HTAVUA Capacity 24-2Ton 36-3Ton 48—4 Ton EEV MODELS AVAILABLE 60—5 Ton RGF2417SEAMCA RCF2417SEAVUA Type F=Furnace Coil RCF2421MEAMCA RCF2421MEAVUA H=Air Handler Coil *RCF2421 UEAMCA *RCF2421 UEAVUA Product Category RGF3617SEAMCA RCF3617SEAVUA C=Evaporator Coil RGF3621MEAMCA RCF3621MEAVUA Rheem *RCF6021SEAMCA *RCF6021SEAVUA [ ]Designates Metric Conversions ROF6024MEAMCA RCF6024MEAVUA PISTON MODELS AVAILABLE RCF2417SPAMCA RCF2417SPAVUA RCF3617SPAMOA RCF3617SPAVUA RCF3621SPAMCA RCF3621SPAVUA RCF4821SPAMOA RCF4821SPAVUA RCF4824SPAMCA RCF4824SPAVUA *Denotes A Coil INTEGRATED • • •- r Ai Coil Specifications a I RCF Series Table 1: Coil Specifications/Airflow Pressure Drop Approx. Face Fins Wet Coil Static Pressure Drop(Inches W.C.)[kPa]@ CFM[L/s] -(Coil Only) Coil Design Cooling Area Per Nominal Model Air Flow Sq.Ft. Inch/ Width Capacity (-)CF Range CFM [mz] Rows 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 [L/sl Deep 12831 [3301 [3781 [4251 [4721 [5191 [5661 [6141 [6611 [708] [7551 [8021 [8501 [8971 RCF2414STAM 600/900 4.56 16/2 14 1 0.165 0.209 0.262 0.325 - - - - - - - - - - 1283/4251 10.42] RCF2417STAM 600/900 4.56 RCF2417SEAM 1 1283/425] 10.421 16/2 1.5-2 0.120 0.157 0.199 0.246 - - - - - - - - - - RCF2417MTAM 600/900 5.70 16/2 17 0.113 0.145 0.181 0.222 - - - - - - - - - - 1283/425] 1.052] RCF3617STAM 700/1300 5.70 16/21 22.5-3 0.113 0.145 0.181 0.222 0.266 0.315 0.368 - - - - - - - RCF3617SEAM [330/614] [0.52] RCF2421MTAM 600/900 5.70 16/2 0.113 0.145 0.181 0.222 - - - - - - - - - - RCF2421MEAM [283/425] [0.52] 1.5-2 RCF2421HTAM 600/900 5.70 16/2 0.113 0.145 0.181 0.222 - - - - - - - - - - 1283/425] [0.52] RCF3621STAM 700//300 [5..70 52] 1612 0.113 0.145 0.181 0.222 0.266 0.315 0.368 - - - - - - - RCF3621 MTAM 700/1300 8.55 16/2 2.5-3 0.062 0.086 0.112 0.140 0.170 0.202 0.236 - - - - - - - RCF3621MEAM [330/614] [0.79] RCF3621 HTAM 700/1300 7.60 13/3 21 0.106 0.125 0.146 0.169 0.194 0.221 0.251 - - - - - - - [330/614] [0,70] RCF4821 MTAM 1100/1800 7.60 13/3 0.106 0.125 0.146 0.169 0.194 0.221 0.251 0.282 0.315 0.350 0.386 0.425 0.465 - [519/8501 [0.701 3.5-4 RCF4821STAM 1100/1800 8.55 16/2 0.062 0.086 0.112 0.140 0.170 0.202 0.236 0.272 0.309 0.349 0.391 0.434 0.480 0.527 [519/850] [0.79] RCF6021STAM RCF6021 SEAM 1400/1600 7.60 13/3 2-5 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 - - RCF6021MTAM [661l7551 10.701 RCF2421UEAM RCF3624MTAM 700/1300 8.55 16/2 0.062 0.086 0.112 0.140 0.170 0.202 0.236 0.272 0.309 - - - - - 1330/6141 10.791 2.5-3 RCF3624[iTAM 700/1300 9•98 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 - - - - - [330/614] 10.931 RCF4824STAM 1100/1800 8.55 16/2 0.062 0.086 0.112 0.140 0.170 0.202 0.236 0.272 0.309 0.349 0.391 0.434 0.480 - 1519/850] [0.79] 24 3,5-4 RCF4824[iTAM 1100/1800 9•98 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.281 - 1519/850] 10.931 RGF6024STAM 1400/1800 9•98 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.281 - RCF6024MEAM [6611755] [0.93] 5 1400/1800 9.98 RCF6024HTAM [6611755] 10.93] 14/3 0.036 0.050 0.065 0.081 0.098 0.117 0.137 0.158 0.180 0.203 0.228 0.254 0.281 - Important Note:Gas furnace heating CFM can exceed the design cooling CFM.Ductwork and coil selection must accommodate the higher of the cooling or gas heating CFM to prevent furnace limit tripping, excessive noise,and coil freeze-up. [ ]Designates Metric Conversions INTEGRATED HOME COMFORT �e Coil Specifications 0 Air I RCF Series Table 1: Coil Specifications/Airflow Pressure Drop (con't.) A rox. Face Fins Dry Coil Static Pressure Drop(inches W.C.)Wa]Q CFM[L/sl - (Coil-Only) Coil Design Heating Area Per Nominal Model Air Flow Sq,Ft. Inch/ Width Rows Capacity ()CF Range[LDS]FM [m'] Deep [283] [3301 [3781 [4251 [4721 [5 91 1661 [141 [6611 [7081 [7551 [021 [8501 [8971 RCF2414STAM 600/1600 4.56 16/2 14 0.118 0.118 0.145 0.176 0.210 0.247 0288 0.332 0.379 0.429 0.483 - - - [283/755] [0.42] RCF2417STAM 600/1500 4.56 16/2 1.5-2 0.116 0.116 0.151 0.190 0.235 0.284 0.338 0.397 0.461 0.530 - - - - RCF2417SEAM [283/707] 10.42] RCF2417MTAM 600/1600 5.70 16/2 17 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 - - - [283/755] (.052] RCF3617STAM 600/1600 5.70 16/2 2.5-3 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 - - - RCF3617SEAM [283/755] [0.52] RCF2421MTAM 600/1600 5.70 16/2 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 - - - [283/755] [0,52] 1.5-2 RCF2422HTAM 600/1600 5.70 RCF2421MEAM [283/755] [0.52] 16/2 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 - - - RCF3621STAM 600/1600 5.70 16/2 0.101 0.101 0.129 0.161 0.196 0.235 0.277 0.323 0.373 0.425 0.482 - - - [283/755] [0.52] RGF3621 MTAM 600/1900 8.55 16/2 2.5-3 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 [283/8961 [0.79] RCF3621 HTAM [283/8 6] 0.60 70 13/3 21 0.043 0.043 0.053 0.066 0.080 0.096 0.115 0.135 0.158 0.182 0.208 0.237 0.267 0.299 RCF3621MEAM [283/896] [0.70] RCF4821MTAM 600/19GO 7.60 13/3 0.043 0.043 0.053 0.066 0.080 0.096 0.115 0.135 0.158 0.182 0.208 0.237 0.267 0.299 [283/896] [0.70] 3.5-4 RCF4821STAM 600/1900 8.55 16/2 0.939 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 [283/896] [0.79] RCF6021STAM RCF6021SEAM 600/1900 7.60 13/3 2-5 0.080 0.080 0.092 0.106 0.121 0.136 0.153 0.171 0.190 0.211 0.232 0.254 0.278 0.302 RCF6021MTAM [283/896] [0.70] RCF2421UEAM RCF3624MTAM 600/1900 8.55 16/2 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 [283/896] [0.79] 2.5-3 RCF3624HTAM 600/1900 9.98 14/3 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 1283/896] [0.93] RCF4824STAM 600/1900 8.55 16/2 0.039 0.039 0.056 0.075 0.095 0.117 0.141 0.166 0.193 0.222 0.252 0.284 0.318 0.353 [283/896] [0.79] 24 3.5-4 RCF4824HTAM 600/1900 9.98 1413 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 1283/896] [0.93] RGF6024STAM 600/1900 9•98 14/3 0.023 0.023 0.038 0.055 0.074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 RGF6024MEAM [283/896] [0.93] 5 RCF6024HTAM 600/1900 9:98 14/3 0.023 0.023 0.038 rO.05510,074 0.095 0.119 0.144 0.171 0.200 0.231 0.264 0.300 0.337 [283/8961 [0.93] Important Note:Gas furnace heating CFM can exceed the design cooling CFM.Ductwork and coil selection must accommodate the higher of the cooling or gas heating CFM to prevent furnace limit tripping, excessive noise,and coil freeze-up. [ ]Designates Metric Conversions INTEGRATED • COMFORT 5 , r • r r 1 r r r DimensionsUncased Coll Coil Sweat(in.)[MMI (in)[MMI Model RCF Coil Weight Shipping Weight MUPOV !�: �.. �:�� is•a� g�;, �, i �����J•.?!n �■1II d� �"I■II 6 w INTEGRATED HOME COMFORT Air Coll Dimensions and Weights �i RCF Series Table 3: Cased Coil Dimensions and Weights Connections Cased Coil Dimensions Coil Sweat(in.)[mm] (in)[mm] Weight Model RCF Liquid Suction A B C Coil Weight Shipping Weight I.D. I.D. (lbs.)[Kg.] (lbs.)[Kg.] 2414ST 3/e[9.53] 3/4[19.051 14 [3561 21 [533] 233/16[584] 43[191 471211 2417SP/2417ST/2417SE 3/e[9.53] 3/4[19.051 171/2[4451 141/2[3681 20 [5081 43[191 48[221 2417MT/2417HT/3617ST/3617SP/3617SE 3/e[9.53] 3/4[19.051 171/2[445] 177/8[454] 1 20 [5081 49[221 541241 2421 MT/2421 HT/3621 ST/3621 SP12421 ME 3/e[9.53] 3/4[19.051 21 [533] 171h[445] 20 [5081 51[231 60[271 3621 MT/4821 ST/4821 SP/3621 ME 3/8[9.53] 3/4[19.05] 21 [533] 257/8[6571 28 [7111 71[321 78[351 2421 UE/3621 HT/4821 MT/6021 ST/6021 SE/6021 MT 3/8[9.53] 7/8[22.231 21 [533] 32 [8131 341k 18761 76[34] 86[391 3624MT/4824ST/4824ST 3/8[9.53] 3/4[19.051 241/2[622] 253/8[6451 321/2 [826] 83[371 93[421 3624HT/4824HT/6024ST/6024HT/6024ME 3/819.531 1 3/4[19.051 241/2[622] 1 301/4[768] 321/2 [826] 100[45] 1 108[48] 'The 14 inch,2 ton RCF coil(2414)is part of the"N-Coil"design series,even though the coil shape resembles an"A"coil design. FIGURE 1: DIMENSIONS CASED A MINUS ONE INCH O 197/e" PLENUM WIDTH 1505 mm] FRONT VIEW ° A > NOTE: FLANGES ARE PROVIDED ` FOR FIELD SIDE VIEW INSTALLATION 1W[12.7 mm] [36.5 mm] SUCTION LINE C 7/s" LIQUID LINE r r • `t `� i i 111.1 mm] • r �,� a �l r r 515/16" [104. mm] 3 113/16"[46 mm] 71 11/4" 21 /16" 5/a" [31.7 mm] [136.5 mm] [550.8 mm] PRIMARY DRAIN ,O Casing to and bottom openings are the same dimensions. 3/4"N.P.T. PRIMARY DRAIN 9 P (VERTICAL& SECONDARY DRAIN 3/4"N.P.T.(VERTICAL) HORIZONTAL) /4"N.P.T.(VERTICAL) [ ]Designates Metric Conversions COMFORT400 INTEGRATED HOME Air I Accessories 0 RCF Series Table 4: Coil Application Coils can be matched to heating products as listed in table below. Coil Model Furnace Width RCF (In.)(mm) Oil Gas 2414ST 2417ST/2417SE _ 14 [356] 2417HT/2417MT 3617ST/3617SE 2417ST/2417SE 171/2[444] 2417MT/2417HT/2417SP 171/2[431] 14 [356] 3617ST/3617SP/3617SE 2421 MT/2421 HT/2421 ME/2421 UE 21 [533] 3621 ST/3621 SP/3621 MT/3621 ME 21 [533] 444z 4821 ST/4821 SP/6021 ST/6021 SE/6021 MT 171/ [ ] 3624MT/3624HT 241/2[622] 4824ST/4824HT/4824SP 241/2[622] 6024ST/6024HT/6024ME 21 [533] Accessories • INDOOR COIL CASING-RXBC(See Table 5) •PLENUM ADAPTER ACCESSORY R X B C — D 14 1 RXBA-AE T INSULATION This plenum adapter accessory is for use with the 241/2" wide I=Insulated cased indoor cooling and heat pump coils.This allows a 241/2" Blank=Uninsulated wide cased coil to be installed on a 28"wide oil furnace.This is a CABINET WIDTH field-installed accessory only. 14=14"[356 mm] 17=17.5"[444 mm] •RXBA-AC(Upflow/Horizontal) 21=21"1533 mm] These plenum adapter accessories are for use when a cooling 24=24.5"[622 mm] coil is matched with a gas furnace of one smaller size. DESIGN SERIES •HORIZONTAL ADAPTER KIT RXHH(See Figure 2) COIL CASING This horizontal adapter.kit is used to convert a upf low or downflow BLOWER UNIT coil ("VUA) for a horizontal application. See Table 4 to order the proper horizontal adapter kit. ACCESSORY Table 4:Horizontal Adapter Kit Model No. RHEEM Coil Mode[ Horizontal Adapter Kit Model No. 2414S RXHH-A01 Table 5:Unit Dimensions and Weights-RXBC Indoor Coil Casings 2417S RXHH-A02 2417M/2421 M/3617S/ RXHH-A03 Depth Air Openings Unit Weight Supply Air/Return 3621S/2421H Model Width Height 3621 M/3624M! Number (in.)[mm] (in.)[mml [mm] Weight Ship.Wt. Width Depth 4821S/48245 RXHH A04 (in.) (Ihs.)[Kg.] (Ibs.)[Kg.] (in.)[mml [mm] 3624H/4824H/ RXHH-A05 RX8C-D14AI 14 [356] 2TA[589] 19 [9] 23[10] 13 [330] 6024S/6024H 2421 U/3621 H/4821 M/ RXBC-D17A1 171/2[445] 20 [508] 18 [81 23[101 16'/2[419] 6021S16021M RXHH A06 RXBC-D21AI 21 [533] 20 [508] 215/a 20 [9] 26[121 20 [508] 1931/3Z FIGURE 2:HORIZONTAL ADAPTER KIT ILLUSTRATION RXBC-D21BI 21 [533] 28 [711] [549]1 27[12] 1 36[17] 20 [508] [508] RXBC-D24AI 241h[622] 32%[826] 1 34[16] 1 44[201 231h[597] � - 1 ' Table 6:Uncased Coil Adapter Kit Uncased Coil Adapter A Uncased Coil Mode[Number RXBA Width(in.)[mml Model RCFP j B1420 131/e[3331 -HUxx14 B17x20 165/9[422] -HUxxl7 AIR FLOW KUM 201/a[511] -HUxx21 %-- i HORIZONTAL-DUAL - i DIRECTION B2420 235/8[599] -HUxx24 • • j [ ]Designates Metric Conversions HORIZ NTAL ADAPTER KIT(RXHH-) INTEGRATED HOME COMFORT Air Accessories �i I RCF Series Accessories (cont.) • UNCASED COIL ADAPTER KIT RXBA- (See Figure 3&4) This uncased coil adapter kit is used to adapt the coil to a fur- nace or ductwork. See Table 6 to order the proper adapter kit. Each kit contains a quantity of 20 adapters. FIGURE 3:UNCASED COIL ADAPTER KIT ILLUSTRATION FIGURE 4:UNCASED COIL ADAPTER KIT ASSEMBLED 1112" [41 mm] T 711/16" [196 mm] 205he A [516 mm] Note:Sliding the coil into the coil rail before attaching coil rack front. ( ]Designates Metric Conversions R-22 TXV Conversion Kits To be used to convert R410-A coil to operate with R-22 FURNACE COIL CROSS REFERENCE CHART ORIGINAL COIL RECOMMENDED ALUMINUM TUBE REPLACEMENT COIL R-22 TXV CONVERSION KIT MODEL NO. RCFA-**2414 RCF2414STAT RXCT-HBA RCFA-**2417 RCF2417STA RXCT-HBA RCFA-**3617 RCF3617STA,RCF2417MTA,or RCF2417HTA RXCT-HBB RCFA-**3621 I RCF3621 STA,RCF2417MTA,or RCF2421 HTA RXCT-HBB RCFA-**4821 RCF4821STA orRCF3621MTA RXCT-HBC RCFA-**4824 ROF4824STA orRCF3624MTA RXCT-HBC RCFA-**6024 RCF6024STA,RCF6024HTA,RCF4824HTA,orRCF3624HTA RXCT-HBD **=AU,HM,or HU COMFORTINTEGRATED HOME Air' Limited Warranty �i RCF Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Parts.......................................................................Five(5)Years which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. The new degree of comfort:" In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating • P.O.Box 17010 Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72917 • www.rheem.com Brampton,Ontario • L6Y OP5 INTEGRATED HOME COMFORT PRINTED IN U.S.A.3/18 OG FORM NO.C71-224 REV.5 Air Conditioners RA13NZ eo The new degree of comfort® EndeavorTm Line Classic® Series N Air Conditioners �, laati rir y !�; WAWW SUN v � � Sam a RA13NZ Cooling Efficiency: 15.2 SEER2/12 EER2 Nominal Sizes: 1 .5 to 5 Ton [5.3 to 17.6 kW] Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW] ISO c us 9001:2015 LISTED *Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star.Ask your Contractor for details or visit www.enemystar.gov. FORM NO.A11.338 REV.2 Table of Contents RA13NZ Table of Contents Features &Benefits..................................................................3 Model Number Identification....................................................4 General Data/Electrical Data....................................................5 Accessories..............................................................................6 Weighted Sound Power...........................................................6 Unit Dimensions.......................................................................7 Clearances ...............................................................................8 ControlWiring ..........................................................................9 Application Guidelines..............................................................9 Refrigerant Line Size Information..................................... 10-13 Performance Data..................................................................14 Limited Warranty....................................................................16 2 Features and Benefits RA13NZ Features and Benefits • 7 mm Condenser Copper Coil:Requires less refrigerant PlusOne®Triple Service Access: 15 in.wide, industry allowing for a smaller and lighter footprint while enhancing leading corner service access,two fastener,removeable reliability corner and individual louver panels-makes repairs easier and faster • PlusOne®Expanded Valve Space:3 in. 4 in.-5 in.service valve space—provides a minimum working area of 27-square inches for easier access 3 Model Number Identification RA13NZ Conditioners R A 13 N Z 24 A J 1 N A LHP Brand Product Category SEER2 Region Refrigerant Capacity BTUIHR Major Series Voltage Type Controls Minor Series Option Code R-Rheem A-Air Conditioners 13-13.4 SEER2 N-North Z-R410A 18-18,000 [5.28 kW] A-1st Design J-1 ph,208-230/60 1-Single Stage N-Nan-Communicating A-1st Design LHP-W/HLPC 24-24,000 [7.03 kW] 30-30,000 [8.79 kW] 36-36,000[10.55 kW] 42-42,000[12.31 kW] 48-48,000[14.07 kW] 60-60,000[17.58 kW] [ ]Designates Metric Conversions Available Models Description RA13NZ18AJl NA Endeavo(rm Line Classic®Series 1 112 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/l/60 RA13NZ18AJl NALHP Endeavofrm Line Classic®Series 1 1/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA13NZ24AJ1 NA Endeavor"m Line Classic®Series 2 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA13NZ24AJl NALHP EndeavorTm Line Classic®Series 2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA13NZ30AJ1 NA Endeavoff Line Classic®Series 21/2 ton 13.4 SEER2 Single-Stage jM Air Conditioner-208/230/1/60 RA13NZ30AJ1 NALHP Endeavorrm Line C/asslc®Series 21/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA13NZ36AJl NA EndeavorTM Line Classic°Series 3 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/l/60 RA13NZ36AJl NALHP EndeavorTm Line Classic®Series 3 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA13NZ42AJl NA Endeavorrm Line Classic®Series 31/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA13NZ42AJl NALHP Endeavor""'Line Classic®Series 31/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA13NZ48AJl NA Endeavoff Line Classic®Series 4 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA13NZ48AJlNALHP EndeavorTm Line Classic,'Series 4 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 RA13NZ60AJlNA Endeavor""'Line Classic®Series 5 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60 RA13NZ60AJl NALHP EndeavorTm Line Classic®Series 5 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/High/Low Pressure-208/230/1/60 Standard Equipment R-410A Refrigerant Maximum 13.4 SEER2 Maximum 9.0 EER2 Scroll Compressor Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit 3-4-5 Expanded Valve Space Composite Basepan 2 Screw Control Box Access 15'Access to Internal Components Quick release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow Single row condenser coil Powder coated paint Rust resistant screws OR code External gauge ports Service trays 4 General Data/Electrical Data RA13NZ General Data Model No. RA13NZ18 RA13NZ24 RA13NZ30 RA13NZ36 RA13NZ42 RA13NZ48 RA13NZ60 Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 718 7/8, 7/8 Refrigerant(R410A)furnished oz.' 70 78 86 106 126 121 186 Compressor Type Scroll Outdoor Coil Net face area-Outer Coil 10.9 13.3 13.3 13.3 14.3 23.5 28.4 Net face area-Inner Coil - - - 12.9 13.9 - - Tube diameter-in. 0.276 0.276 0.276 0.276 0.276 0.276 0.375 Number of rows 1 1 1 2 2 1 1 Fins per inch 24 24 24 24 24 24 22 Outdoor Fan Diameter-in. 20 24 24 24 24 26 26 Number of blades 2 3 3 3 2 3 3 Motor hp 1/7 1/6 1/6 1/6 1/5 1/5 1/5 CFM 1765 3439 3439 2957 2830 4095 4189 RPM 1075 825 825 825 825 850 850 Wafts 154 197 197 188 145 203 204 Shipping weight-ibs. 1 148 1 166 1 170 1 193 224 251 279 Operating weight-lbs. 141 159 163 186 217 244 272 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 2081230-1-60 208/230-1-60 2081230-1-60 208/230-1-60 208/230-1.60 208/230-1-60 Maximum overcurrent protection(amps)2 20 25 30 30 40 50 50 Minimum circuit ampacity3 12 16 19 18 25 33 34 Compressor Rated load amps 9 12 14 13 1 19 25 26 Locked rotor amps 43 60 68 83 110 120 150 Condenser Fan Motor Full load amps 0.8 0.8 0.8 0.8 0.8 1.0 1.0 Locked rotor amps 1.5 1.5 1.5 1.7 1.5 2.4 2.4 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. 5 Accessories/Weighted Sound Power RA13NZ Accessories Model No. RA13NZ18 RA13NZ24 RA13NZ30 RA13NZ36 RA13NZ42 RA13NZ48 RA13NZ60 Compressor crankcase heater' 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al Compressor time delay RXMD-1301 RXMD-801 RXMD-B01 RXMD-1301 RXMD-B01 RXMD-1301 RXMD-801 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXA13-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC (24 VAC,50/60 Hz) Solenoid Coll 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2tTVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Classic Top Cap w/Label 1 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 "Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dBA) Unit Size-Voltage,Series Standard TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) Rating(dBA) 125 250 500 1000 2000 4000 8000 RA13NZ18 70 46.7 54.5 60.8 59.9 58.2 53.4 46.9 RA13NZ24 71 46.3 58.4 62.7 59.0 58.0 52.4 47.3 RA13NZ30 71 47.0 62.4 62.6 59.3 57.2 55.7 47.1 RA13NZ36 71 45.5 58.4 1 63.9 59.2 56.6 52.1 47.7 RA13NZ42 68 46.4 53.7 59.7 55.9 55.3 53.6 50.3 RA13NZ48 71 49.2 56.2 62.3 59.5 57.9 49.9 40.7 RA13NZ60 76 49.1 58.7 68.7 65.2 63.5 60.1 55.7 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) 6 Unit Dimensions RA13NZ Unit Dimensions OPERATING SHIPPING Model H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) No. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA13NZ18 25.00 635 29.75 756 29.75 756 26.50 673 32.38 822 32.38 822 RA13NZ24 25.00 635 33.75 857 33.75 857 26.50 673 36.38 924 36.38 924 RA13NZ30 25.00 635 33.75 857 A75 857 26.50 673 1 36.38 924 36.38 924 RA13NZ36 25.00 635 33.75 857 33.75 857 26.50 673 36.38 924 36.38 924 RA13NZ42 27.00 686 33.75 857 33.75 857 28.50 724 36.38 924 36.38 924 RA13NZ48 39.00 991 35.75 908 35.75 908 40.50 1029 38.38 975 38.38 975 RA13NZ60 45.00 1 1143 35.75 908 35.75 908 46.50 1181 38.38 975 38.38 975 ALLOW 60"[1524 mm] OF CLEARANCE A R 1 5 C K L n Ft G E H SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-02-00 7 - s o m CLEARANCES N Z No m m WALL WALL -- 611 24'r (152.4) (609.6) Service 24" 12" 12" D•_ (609.6) (304.8) (304.8) r" Service 6" (152.4 x 611 (152.4) 12" (304.8) o , g WALL 24" 24" 24" (609.6) (609.6) (609.6) Service Service Service 18„ 24" 24" (457.2) (609.6) (609.6) 24" recommended 24" recommended 6" minimum 6" minimum NOTE: NUMBERS IN ()= mm IMPORTANT:When installing multiple units in an alcove,roof well or partial y enclosed area,ensure there is adequate ventillation to prevent re-circulation of discharge air. ST-A1225-01-00 Control Wiring/Application Guidelines RA13NZ Control Wiring FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(WA1K)AND W2(W/BL)BE JUMPERED TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE ® © ® ® Y G R BR-BROWN WIRE YL-YELLOW WIRE OR-BROWN WIRE X-WIRE CONNECTION R-RED WIRE YL-YELLOW WIRE W1BK-WHITE WIRE WITH BLACK STRIPE G/BK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION' TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX * W/BL TYPICAL CONDENSING R TYPICAL CONDENSING R UNIT UNIT X W/BK G/BK G _YL Y YL YL BR C BR BR PU Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01 -in.wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 550F(12.80% 3. Maximum outdoor operating air temperature is 1250F(51.70C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory-supplied filter drier must be installed. 9 Refrigerant Line Size Information a 13.4 SEER2 Single-Stage Air-Conditioners N CD Apply Long Line Guidelines if Equivalent Length(Feet) r Allowable Allowable Linear Line Length Exceeds 'm Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 51-75 75-100 101-125 126-150 151-175 176-200 201-225 226-250 N Size Size CD (-)A13NZ Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier o 3 1/4" 5/8" N/A 25/1.00 50/0.99 62/0.98 43/0.98 24/0.97 5/0.97 MR -NR MR MR o. 5/16" 5/8" N/A 25/1.00 50/0.99 75/0.98 98/0.98 93/0.97 88/0.97 83/0.96 78/0.96 73/0.95 68/0.94 1.5 Ton 3/8" 5/8" 178 25/1.00 50/0.99 75/0.98 100/0.98 100/0.97 100/0.97 10010.96 100/0.96 100/0.95 100/0.94 **SEE NOTE 3 1/4" 3/4"** N/A 25/1.00 50/1.00 62/0.99 43/0.99 24/0.99 5/0.99 MR MR MR MR 5/16" 3/4"** N/A 25/1.00 50/1.00 75/0.99 98/0.99 93/0.99 88/0.99 83/0.99 78/0.98 73/0.98 68/0.98 3/8" 3/4-- 178 25/1.00 50/1.00 75/1.00 100/0.99 100/0.99 100/0.99 100/0.99 100/0.98 100/0.98 100/0.98 1/4" 5/8" N/A 25/0.99 50/0.98 21/0.97 MR - MR MR MR MR MR MR . 5/16" 5/8" 213 25/0.99 50/0.98 75/0.97 87/0.96 77/0.95 69/0.94 61/0.93 53/0.92 45/0.91 3710.90 3/8" 5/8" 142 25/0.99 50/0.98 75/0.97 100/0.96 100/0.95 100/0.94 98/0.93 95/0.92 92/0.91 -89/0.96, 2 Ton 1/4" 3/4" N/A 25/1.00 50/1.00 21/0.99 MR MR MR MR MR MR MR 5/16" 3/4" 213 25/1.00 50/1.00 75/0.99 87/0.99 77/0.98 69/0.98 61/0.98 53/0.97 45/0.97 37/0196, 3/8" 3/4" 142 2511.00 50/1.00 75/0.99 100/0.99 100/0.98 100/0.98 98/0.98 95/0.97 93/0.97 90/0.96 5/16" 5/8" N/A 25/0.99 50/0.98 75/0.96 70/0.94 59/0.93 48/0.91 36/0.90 MR MR MR 3/8" 5/8" 142 25/0.99 50/0.98 75/0.66 100/0.94 98/0.93 '94/0.91 90/0.90 MR MR MR 2.5 Ton 5/16" 3/4" 213 25/1.00 50/0.99 75/0.99 70/0.98 59/0.98 48/0.97 36/0.96 25/0.96 13/0.95 MR 3/8" 3/4" 142 25/1.00 50/0.99 75/0.99 100/0.98 98/0.98 94/0.97 90/0.96" 86/0.96 82/0.95: 78/0.95 ' 5/16" 5/8" N/A 25/0.99 50/0.97 6610.94 49/0.92 `32/0.90 MR MR MR MR MR 3/8" 5/8" 108 25/0.99 50/0.97 75/0.94 95/0.92 89/0.90 MR MR MR MR MR ` 5/16" 3/4" N/A 25/1.00 50/0.99 66/0.98 49/0.98 32/0.97 15/0.96 MR MR MR MR 3/8" 3/4" 108 25/1.00 50/0.99 75/0.98 95/0.98 89/0.97 84/.0.96 78/0.95- '72/0.94 67/0.93 61/0.93 3 Ton 1/2" 3/4" 54 25/1.00 50/0.99 75/0.98 100/0.98 100/0.97 100/0.96 100/0:95 .100-/0.94 ' 100/0.93 100/0.93. 5/16" 7/8" N/A 25/1.00 50/1.00 66/1.00 49/0.99 32/0.99 15/0.99 MR MR MR MR 3/8" 7/8" 108 25/1.00 50/1.00 75/1.00 1 95/0.99 89/0.99 84/0.99 78/0.98 72/0.98 67/0.98 61/0.97 1/2" 7/8" 54 25/1.00 50/1.00 75/1.00 100/0.99 100/0.99 100/0.99 100/0.98 100/0.98 100/0.98 100/0.97 3/8" 3/4" 150 25/0.99 50/0.98 75/0.97 88/0.96 80/0.95 72/0.94 65/0.92 57/0.91 49/0.90 MR 1/2" 3/4" 75 25/0.99 50/0.98 75/0.97 100/0.96. 100/0.95 10610.94 100/0.92 100/0.91 100/0.90 MR- " 3.5 Ton 3/8" 7/8" 150 25/1.00 50/1.00 75/0.99 88/0.99 80/0.99 72/0.98 65/0.97 57/0.97 49/0.96 42/0.96 1/2" 1 7/8" 75 25/1.00 50/1.00 75/0.99 100/0.99 100/0.99 100/0.98 100/0.97 100/0.97 100/0.96 100/0.96 NOTES: 1) Do not exceed 200 ft linear line length. 2) *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. 3)**3/4"suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. Refrigerant Line Size Information (Con't.) 13.4 SEER2 Single-Stage Air-Conditioners Apply Long Line Guidelines if Equivalent Length(Feet) Allowable Allowable Linear Line Length Exceeds Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 51-75 1 76-100 1 101-125 1 126-150 1 151-175 1 176-20D 201-225 226-250 Size Size (-)A13NZ Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier 3/8" 3/4" 148 25/0.99 50/0.98 75/0.96 77/0.95 67/0.93 57/0.92 46/0.91 MR MR MR 1/2" 3/4" 74 25/0.99 50/0.98 75/0.96 100/0.95 10010.93 100/0.92 100/0.01 MR MR MR 4 Ton 3/8" 7/8" 148 25/1.00 50/0.99 75/0.99 77/0.98 67/0.97 57/0.97 46/0.96 36/0.96 26/0.95 15/6.95 1/2" 718" 74 25/1.00 50/0.99 75/0.99 100/0.98 100/0.97 100/0.97 10010.96 100/0.96 99/0:95 97/0.95'. 3/8" 3/4" 78 25/0.99 50/0.97 75/0.94 61/0.92 461 HO MR MR MR MR MR 1/2" 3/4" 39 25/0.99 50/0.97 75/0.94 100/0.92 .100/0.90 MR MR MR MR MR 3/8" 7/8" 78 25/1.00 50/0.99 75/0.98 61/0.97 46/0.96 32/0.95 18/0.94 MR MR MR 1/2" 7/8" 39 25/1.00 50/0.99 75/0.98 100/0.97 100/0.96 100/0.95 97/0.94 95/0.94 92,/0.93 89/0.92 5 Ton 3/8" 1-1/8" 78 25/1.01 50/ 1.01 75/1.00 61/1.00 46/0.99 32/ 0.99 18/0.99 MR MR MR 1/2" 1-1/8" 39 25/1.01 50/1.01 75/1.00 i 100/1.00 100/0.99 100/0.99 97/0.99 95/0.99 92/ 0.99 89/0.98 NOTES- 1) Do not exceed 200 ft linear line length. 2) *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. 3)**3/4"suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. z Co W f0 Z m N r 7 m N ID 7 O 3 _ w .1 N Refrigerant Line Size Information (Con't.) a 13.4 SEER2 Single-Stage Air-Conditioners 2CDN � Apply Long Line Guidelines if Equivalent Length(Meters) Allowable Allowable Linear Line Length Exceeds Liquid Line Suction Line Those Shown Below (Feet) <8 8-15 16-23 24-30 31-38 39-46 47-53 54-61 62-69 70-76 �? Unit Size Size Size N mm[in.] mm[in.] (-)A13NZ Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier o 6.35[1/4] 15.88[5/8] N/A 8/1.00 15/0.99 19/0.98 13/0.98 7/0.97 2/0.97 NR NR NR- NR o. 7.94[5/161 15.88[5/8] N/A 8/1.00 15/0.99 23/0.98 30/0.98 28/0.97 27/0.97 25/0.96 24/0.06 22/0.95 21/0.94 ' 5.3 KW [1.5 Ton] 9.53[3/8] 15.88[5181 54 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 30/0.97 3010.96 30/0.96 30/0.95 3010.94 **SEE 6.35[1/4] 19.05[3/4]** N/A 8/1.00 15/1.00 19/0.99 13/0.99 7/0.99 2/0.99 NR NR NR NR NOTE 3 7 94[5/16] 19.05[3/4]** N/A 8/1.00 15/1.00 23/0.99 30/0.99 28/0.99 27/0.99 25/0.99 24/0.98 22/0.98 21/0.98 9.53[3/8] 19.05[3/41-- 54 8/1.00 15/1.00 23/0.99 30/0.99 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 6.35[1/41 15.88[5/8] N/A 8/0.99 15/0.98 6/0.97 NR NR NR NR NR NR NR " 7.94[5/16] 15.88[5/8] 65 8/0.99 15/0.98 23/0.97 27/0.96 23/0.95 21/0.94 19/0.93 16/0.92 14/0.91 11/0.90 7.0 KW 9.53[3/8] 15.88[5/81 43 8/0.99 15/0.98 23/0.97 30,/0.96 3010.95 30/0.04 30/A93 . `29/0,92 28/0.91 27/0.90 [2 Ton] 6.35[1/4] 19.05[3/4] N/A 8/1.00 15/1.00 6/0.99 NR , NR NR NR NR' NR NR . 7.94[5/16] 19.05[3/41 65 8/1.00 15/1.00 23/0.99 27/0.99 23/0.98 21/0.98 19/0.98 16/0.97 14/0.97 1-1/0.96 9.53[3/81 19.05[3/41 43 8/1.00 15/1.00 23/0.99 30/0.99 30/0.98 30/0.98 30/0.98 29/0.97 28/0.97 27/0.96 7.94[5/16] 15.88[5/8] N/A 8/0.99 15/0.98 23/0.96- 2110.94 0.94 18/0.931. 15/0.91 . '11/0.90. NR NR NR 8.8 KW 9.53[3/81 15.88[5/81 43 8/0.99 15/0.98 23/0.96 30/0.94 '30/0.93 29/0.91 - ;27-/0.90. NR - NR 'NR [2.5 Ton] 7.94 15/16] 19.05[3/4] 65 8/1.00 1510.99 23/0.99 21/0.98 18/0.98 15/0.97 11/0.9-6 8/0.96- 4/0.95 NR 9.53[3/8] 19.05[3/4] 43 8/1.00 15/0.99 23/0.99 30/0.98 30/0.98 29/0.97 27/'0.96" 26/0.66 25/0.95 24/0.95 7.94[5/16] 15.88[5/81 N/A 8/0.99 15/0.97 20/6.94-° 15/'0.92 10/0.90 NR- NR NR NR NR 9.53[3/8] 15.88[5/8] 33 8/0.99 15/0.97 - .23/0.94' '29/0.92 27/0.90 NR' NR NR NR NR 7.94 15/16] 19.05[3/41 N/A 8/1.00 15/0.99 20/0.98 15/0.98 10/0.97 5J 0.96' NR NR NR NR 10.6 KW 9.53[3/8] 19.05[3/41 33 8/1.00 15/0.99 23/0.98 29/0.98 27/0.97 26/0.96' 24/0.95 22/0.94 20/0.93 19/0.93 [3 Ton] 12.70[1/2] 19.05[3/4] 17 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 .30/0.96, 30/0.95` 30/0.94 30/0.93 3010.93. 7.94[5/16] 22.23[7/8] N/A 8/1.00 15/1.00 20/1.00 15/0.99 10/0.99 5/0.99 NR NR NR - NR ' 9.53[3/8] 22.23[7/8] 33 8/1.00 15/1.00 23/1.00 29/0.99 27/0.99 26/0.99 24/0.98 22/0.98 20/0.98 19/0.97 12.70[1/21 22.23[7/81 17 8/1.00 15/1.00 23/1.00 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 30/0.97 9.53[3/8] 19.05[3/41 46 8/0.99 15/0.98 23/0.97 27/0.96 24/0.'95 22/0.94 20/0.92 17/0.91, 15 k 0.90 NR. 12.3 KW 12.70[1/2] 19.05[3/41 23 8/0.99 15/0.98 23/0.97 36/0.96 "30/0.95' 30/0.94 30/0.92 30/0:91 30/0.90 NR [3.5 Ton] 9.53[3/8] 22.23[7/81 46 8/1.00 15/1.00 23/0.99 27/0.99 24/0.99 22/0.98 20/0.97 17/0.97 1510.96 1"3/0.96 12.70[1121 22,23 17/81 23 8/1.00 15/1.00 23/0.99 30/0.99 30/0.99 30/0.98 30/0.97 30/0.97 30/0.96 30/0.96 NOTES: 1) Do not exceed 61 m linear line length. 2) *Do not exceed 30m vertical separation if outdoor unit is above indoor unit 3)**19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. Refrigerant Line Size Information (Con't.) 13.4 SEER2 Single-Stage Air-Conditioners . Allowable Allowable Apply Long Line Guidelines if Equivalent Length(Meters) Linear Line Length Exceeds Liquid Line Suction Line Those Shown Below Feet <8 8-15 16-23 24-30 31-38 39-45 47-53 54-61 62-69 70-76 Unit Size Size Size ( ) mm[in.] mm[in.] (-)A13NZ Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier 9.53[3/8] 19.05[3/4] 45 8/0.99 15/0.98 23/0.96 24/0.95 20/0.93 1710.92 14/6.91 NR NR NR 12.7[1/2] 19.05[3/4] 23 8/0.99 15/0.98 23/0.96 30/0.95 30/0.93 30/0.92 30/0.91 NR NR NR 14.1 KW 9.53[3/8] 22.23[7/8] 45 8/1.00 15/0.99 23/0.99 24/0.98 20/0.97 17/0.97 14/0.96 11/0.96 8/0.95 5/0.95 [4 Ton] 12.7[1/2] 22.23[7/8] 23 8/1.00 15/0.99 23/0.99 30/0.98 30/0.97 30/0.97 30/0.96 30/0.96 30/0.95 30/0.95 9.53[3/8] 19.05[3/4] 24 8/0.99 1510.97 23/0.94 19/0.92 14/0.90 NR NR NR NR NR 12.7[1/2] 19.05[3/4] 12 8/0.99 15/0.97 23/0.94 30/0.92 30/0.90 NR NR NR NR NR 9.53[3/8] 22.23[7/8] 24 8/1.00 15/0.99 23/0.98 19/0.97 14/0.96 10/0.95 5/0.94 NR NR NR 17.6 KW 12.7[1/2] 22.23[7/8] 12 8/1.00 15/0.99 23/0.98 30/0.97 30/0.96 30/0.95 30/0.94 29/0.94 28/0.93 27/0.92 [5 Ton] 9.53[3/8] 28.58[1-1/8] 24 8/1.01 15/1.01 23/1.00 19/1.00 14/0.99 10/ 0.99 5/0.99 NR NR NR 12.7[1/2) 1 28.58[1-1/8] 12 8/1.01 15/1.01 23/1.00 30/1.00 30/0.99 30/0.99 30/0.99 29/0.99 28/ 0.99 27/0.98 NOTES: 1) Do not exceed 61 m linear line length. 2) *Do not exceed 30m vertical separation if outdoor unit is above indoor unit 3)**19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. a � 2CD N y r m N m 7 O 3 w fA 0 Performance Data RA13NZ Performance Data @ AHRI Standard Conditions- Cooling Designated Tested Combination(OTC) Total Capacity Net Sensible Net Latent Indoor CFM Outdoor Unit Indoor Call BTU/H[kW] BTU/H IkW] BTU/H[kW] SEER2 EER2 ILA] RA13NZ18AJ1 RCFZ2417STAN 17,100 [5.0] 13,000 [3.8] 4,100 13.4 9.0 600[283.21 RA13NZ24AJ1 RCFZ2417STAN 22,800 [6.7] 17,000 [5.0]. 5,800 13.4 9.0 735[346.9] RA13NZ30AJ1 RCFZ3617STAN 28,400 [8.3] 20,800 [6.1] 7,600 13.4 9.0 910[429.5] RA13NZ36AJ1 RCFZ3617STAN 34,200[10.0] 24,600 [7.2] 9,600 13.4 9.0 1,025[483.7] RA13NZ42AJ1 RCFZ4821STAN 40,000[11.7] 29,500 [8.6] 10,500 13.4 9.0 1,300[613.5] RA13NZ48AJ1 RCFZ4821STAN 46,000[13.5] 33,500 [9.8] 12,500 13.4 9.0 1,425[672.5] RA13NZ60AJ1 RCFZ6024STAN 55,500[16.3] 39,000[11.4] 16,500 13.4 9.0 1,600[755.11 NOTE:This data includes OTC(Designated Test Combination)ratings and is for reference purposes only.A full listing of official ratings and system match-ups,along with downloadable certificates,can be accessed from the AHRI website:www.ahridirectory.org. [ ]Designates Metric Conversions 14 The new degree of comfort GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required).................................Ten(10)Years period stated,in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Before proceeding with installation,refer to installation instructions packaged with each model,as well as complying with all Federal, State,Provincial,and Local codes,regulations,and practices. ©2023 Rheem Manufacturing Company.Rheem trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating • 5600 Old Greenwood Road Rheem Canada Ltd./Lt6e • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72908 • www.rheem.com Brampton,Ontario • L6Y OP5 • rheem.ca PRINTED IN U.SA.2/23 QG FORM NO.A11-338 REV.2 y MR j h ti 7 it S t loop ill—Oil EXIST. BILCO o DOOR UP U EXISTING R C E C ., . ° 0 ° NOOK ° 51-9„ 321 RIVERSIDE DR J ELECTRIC o AC COMPRESSOR R IVE R H EAD, NY 11901 WATER cx RHEEM RA13NZ36AJ1 NA � ¢ HEATER 3 2 49 WINDOWS ( ) " (516)376-8594 EXISTING (3)2x8 WOOD BEAM W.H. • a cfl _ _ � E.F. EXIST. EXISTING 6-1/2"STEP AC COIL ADDED TO EXISTING O d BATH s.P. EXISTING Li BATH KITCHEN EXISTING DEN , HEATING SYSTEM p °� ° s RHEEM RCF3617STAMC BEDROOM CLG.HGT.:8'6-1/2" a) ti ° � � LIN. REF. ® I r co v EXISTING OIL =_ FIRED FURNACE &D (jl O� OOP _ EXIST. CL. CL. N N DN _ = __ -- SLAB ON o EXISTING (3)2x8 WOOD BEAM GRADE N N U) U) EXISTING O b EXISTING FINISHED LIVING ROOM EXISTING WOOD W O EXISTING BURNING FIREPLACE O m STORAGE Y EXISTING ON BRICK HEARTH. FP N BEDROOM J � CEILING HEIGHT-6'-11" p� � Z BEDROOM VENTED THROUGH � Client Info LL O cn Q BRICK CHIMNEY o N UP ~ CL. GEERTRUI VAN DE HEYNING w a, &ALAN DAVIES CL. 11'-7" 835 Strohson Road Cutchogue, NY 11935 (3) 32"x49"WINDOWS Project Info a LEGALIZE EXISTING GARAGE FLOOR CONSTRUCTION CONVERSION TO LIVING SPACE HARDWOOD FLOORING 835 Strohson Road 3/4" PLYWOOD SUB FLOOR Cutchogue, NY 11935 BASEMENT PLAN FIRST FLOOR PLAN 2x JOIST @ 16"o.c. SCALE: 1/4" = V-0" SCALE: 1/4"= 1'-O" 0 APPROVED AS NOTED 0A7_•,.1.do B.P.# 3 OCCUPANCY OR Q FEE o-v.n BY,. USE IS UNLAWF( . NOTIFY BUILDING DEPARTMENT AT� WITHOUT CEI�'�I . /1f1 631-765.1802 8AM TO 4PM FOR WIS L FOLLOWING INSPECTIONS: OF OCCUPANCY c 1. FOUNDATION-TWO REQUIRED (n o RIDGE _ _ _ _ _ _ _ _ _ _ _ FOR POURED CONCRETE Z +, 1-0 2. ROUGH-FRAMING&PLUMBING O ,o- 3. INSULATION (n j EXISTING ASPHALT 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. Additional a UNCONDITIONED ROOF SHINGLES ALL CONSTRUCTION SHALL MEET THE i Certsficat>on ATTIC REQUIREMENTS OF THE CODES OF NEW May Be Require YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS 2x6 CLG.JST.@16"O.C. RETAIN STORM WATER dOF R-30 BATT INSULATION PURSUANT TO CHAPTE 6 v 1l2"GYPSUM BOARD COMPLY WITH ALL CODES OF OF THE TOWN CODE. EXISTING CEDAR NEW YORK STATE&TOWN CODES N EXISTING SHINGLE SIDING AS REQUIR D AND CONDITIONS OF TYVEX WRAP sOUTHOLD TOV N ZBA co DEN 1/2"CDX PLYWOOD ao 2"X4"STUDS @ 16"O.C. EO=Toll im BOARD R-13 BATT INSULATION SOUTI IDT o''iTR1JSTEES = -� •T'� R IRED �p A%, 1/2"GYPSUM BOARD �%YS.�i� ARC} FIRST FLOOR _ _ _ _ _ _ _ _ _ _ ` � " 7_10" 3/4"PLYWOOD ton, min CONSTRUCTION NOTES: LEGEND R-19 BATT INSULATION SChO 2x FLR.JST.@16"O.C. ` FOR COMPRESSIVE STRENGTH OF �- �. � CONCRETE SEE TABLE:R402.2 ON GRADE D - � NEW FOUNDATION DWG A.5 (0 0) EXISTING FOUNDATION . . ��� `"� SEE DETAILS � ANY/ALL LUMBER THAT COMES WALL AND GARAGE fi 111 O `add INTO CONTACT WITH CONCRETE NEW INTERIOR - 4 � SHALL BE ACQ WALL&PARTITION SLAB ALL CORNERS OF THE:FRAMING NEW EXTERIOR TO BE CONTINUOUS STRAP DOWN WALL SECTION A-A WITHIN A MIN. OF 10%OF THE LEAST HORIZONTAL DIMENSION NEW WINDOW SCALE: 1/4"=1'-O" BASEMENT & 1st COLLAR TIES TO LOCATED IN THE O FLOOR PLANS & UPPER 1/3 RD OF THE ATTIC BATH WINDOW TO CONFORM O NEW DOOR TO THE HAZARDOUS GLAZING APPLICATION TO LEGALIZE THE FOLLOWING:REU SECTION A—A RE OFTIREMENTS AS PER SECTION NEWYORKSTATERES. 4 ODE. O SD DETECTOR SMOKE HE - DEN CONVERTED FROM RI Drawn B ORIGINAL I NAL y Checked By TEMPERED GLASS REQUIRED AT O CO CARBON DETECTOR MONOXIDE GLASS OPENINGS WITHIN 18 AFF GARAGE J.E.M. J.E.M. EXHAUST FAN TO BLOCK UNDERSIDE OF NON-BEARING O EF EXTERIOR PER R303.3 INTERIOR WALLS RUNNING PARALLEL - AC COMPONENTS ADDED TO EXISTING Drawing No. W/FLOOR JOIST. HEATING SYSTEM A- 1 Sheet of