Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
48202-Z
Of Sao Tyo`o Town of Southold # * P.O. Box 1179 0 53095 Main Rd Southold, New York 11971 �'r�ounrc. E' CERTIFICATE OF OCCUPANCY No: 45766 Date: 11/19/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 740 Poquatuck Ln Orient,NY 11957 Sec/Block/Lot: 27.-3-4.5 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 07/13/2022 Pursuant to which Building Permit No. 48202 and dated: 08/24/2022 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Mary Roman, Strauss Audrey 2002 Fam Trust,Ellen Birenbaum Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 48202 09/24/2024 PLUMBERS CERTIFICATION: Aut 0 ze Signature o�SufFoc,t�o TOWN OF SOUTHOLD =a aye BUILDING DEPARTMENT H 2 TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48202 Date: 8/24/2022 Permission is hereby granted to: Roman, Mary PO BOX 655 Orient, NY 11957 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 740 Poguatuck Ln, Orient SCTM #473889 Sec/Block/Lot# 27.-3-4.5 Pursuant to application dated 7/13/2022 and approved by the Building Inspector. To expire on 2/2312024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 i Bui g Inspector o��oF so�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q sean.devlin(&-town.southold.ny.us Southold,NY 11971-0959 COUNVI BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mary Roman Address: 740 Poquatuck Ln city,Orient st: NY zip: 11957 Building Permit* 48202 section: 27 Block: 3 Lot: 4.5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunation Solar License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 6.8kW Roof Mounted PV Solar (17) SL65-54BHJ-400V Modules Added to (28) SN20-72MBE-390V Modules for a Total of 17.72kW Notes: Added Panels to Existing System (Solar) Inspector Signature: Date: September 24, 2024 Copy ho�aOF SOUlyO� # # TOWN OF SOUTHOLD BUILDING DEPT. `ycourmN�' 631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL �o [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: &,kvt � DATE l INSPECTOR *pE SOUTyo{o 4E41___ <F�5--99,,/ "v �<i -- # TOWN, OF SOUTHOLD -BUILDIN"EPT. °ycou 631-765-1802 n INSPECTION ' [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [. ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE& CHIMNEY [ ] 'FIRE SAFETY INSPECTION. . [ ] FIRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT PENETRATION"' : [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION — [ ] PRE C/O [ ] RENTAL -REMARKS: l "A�4/'QA 1-0 r__ b,AW9,6:�;,74 ct f,_f' ®4 7j;�DA oAF�ld DATE INSPECTOR OF SOUIyO� H V w 2.� ` 9 v 720-� # * , TOWN OF SOUTHOLD BUILDING DE . orm 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ RESAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL FIREPLACE &'CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ . ] .PRE C/O [ ] RENTAL REMARKS: ae` e G o. r oork 6 DATE -INSPECTOR - rq4f so + �Z g, # # TOWN OF SOUTHOLD BUILDINGPDEPT. cn 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [. ]. INSULATION/CAULKING ] FRAMING /STRAPPING [ ] FINAL f ] FIREPLACE-& CHIMNEY [ ] .FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION. [ ] FIRE RESISTANT PENETRATION' [ ] ELECTRICAL-(ROUGH) ELECTRICAL.(FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] . RENTAL �1 REMARKS: cr —CZ DATE 21 INSPECTOR Graham Associates 256-A Orinoco Drive,Brightwaters,NY 11718 Building Consultants&Expeditors (631)665-9619 Fax(631)969-0115 September 14, 2022 2 Town of Southold Post Installation Certification im 2 6 2023 ED Re: Permit# 48202 Tn�nin�BUILDING DEPT nf:ennMUrn n Birenbaum & Roman Residence 740 Poquatuck Lane, Orient Inspection Date: 9/14/2022 To Whom It May Concern, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Graham Associates to be in compliance with the minimum requirements of the 2020 New York State Residential Building Code; Town Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-10. If you have any further questions, do not hesitate to call. Since y. cYfae)� FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION(1ST) a� �y ------------------------------------ C FOUNDATION (2ND) z 0 ROUGH FRAMING& PLUMBING vl r INSULATION PER N.Y. y STATE ENERGY CODE �.n l 0ID vh ti FINAL (/ � .� l� t a2Lu ADDITIONAL COMMENTS 04 OZ `1- - 2H lbecA 6 . • � b � z �x e � b 1 SuvFot,t , '0`9 c�Gy2 TOWN OF SOUTHOLD—BUILDING DEPARTMENT y x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtoLAM.gov f Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �n PERMIT NO. Building Inspector: JUL 1 121192 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name:Ellen Birenbaum scTM# s000-27-3-4.5 Project Address:740 Poquatuck Lane, Orient, NY 11957 Phone#:(917) 232-1422 Email:ebirenba@gmail.com__ Mailing Address:P.O. Box 655, Orient, NY 11957 CONTACT PERSON: Name: Tammy Lea/Sunation Solar Systems___. Mailing Address: 171 Remington Blvd,- Ronkonkoma, NY 117.79 Phone#: 61-750-94 Email: ermitt inm -- ._._. ._.. 3- 45- - - _ - - - -- p -----g@sunation.co_ DESIGN PROFESSIONAL INFORMATION: Name:Michael Dunn Mailing Address:256A Orinoco Drive, Bri_ghtwaters,_NY 11718 Phone#:631-665-9120 Email:glenn@grahamassociatesny_`com CONTRACTOR INFORMATION: Name_Scott Mas_kin/Sunation Solar Systems_ Mailing Address: 171 Remington Blvd.,_ Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:P__. er-__mittin sunation.com _.-. _ g@ _ DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 'Say Sty'.°D Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to - this property? ❑Yes 8 No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law: Application Submitted By(print name): SC Maskin BAuthorized Agent []Owner Signature of Applicant: Date: N7 Ia STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he.is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of tary Public TAMMY LEA Notary Public.State of New York Registration No.01 LE6410842 ualified in Suffolk County OWNER AUTHORIZATION Commission Expires November 2,20a � (Where the applicant is not the owner) I, 1�11eh 13i re;, bait s" residing at 740 Poquatuck Lane Orient do hereby authorize Scott Maskin to apply on my behalf t -the can o Sodthold Building Department for approval as described herein. Owner's Signature D to Ellen Birenbaum Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector y � TOWN OF SOUTHOLD �Q Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 �a-Cp l Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr D-southoldtownny.gov_�,seanda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ' ELECTRICIAN INFORMATION (All information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin i License No.: 33412-ME email: permitting@sunation.com s Address: 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Ellen Birenbaum Address: 740 Poquatuck Lane, Orient, NY 11957 Cross Street: Phone No.: (917) 232-1422 Bldg.Permit#: email: ebirenba@gmaii.com Tax Map District: 1000 Section: 27 Block 3 Lot: 4.5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: .A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION r D nn JUL 1 121199 Request for Inspection Formals BUILDING DEPT. TOWN OF SOUTHOLD Mejia, Evelin From: Ellen Birenbaum <ebirenba@gmail.com> Sent: Thursday, February IS,2024 2:53 PM To: Mejia, Evelin Subject: 6 month extension request permit#48202 As per our conversation, I am writing to request a 6 month extension for building permit 448202 (solar panels). In addition, I am requesting a building permit application form for HVAC. Also,regarding our open generator permit#41092, I would like to renew the permit.I understand the cost is $117.50. Ellen Birenbaum 740 Poquatuck Lane Orient,NY 11957 917-232-1422 ebirenba@gmail.com ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 1 Suffolk County Dept. of Labor, Licensing & Consumer Affairs HOME IMPROVEMENT LICENSE Name SCOTT MASKIN Business Name This certifies that the SUNation Solar Systems Inc bearer is duly licensed License Number H-44104 by the County of suffolk Issued: 03/06/2008 W At., T. Rogery Expires: 03/01/2026 Commissioner Suffolk County Dept. of Labor, Licensing & Consumer Affairs MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN A" Business Name SUNATION SOLAR SYSTEMS INC This certifies that the bearer is duly licensed License Number ME-33412 by the County of suffolk Issued: 06/24/2003 R prago- Expires: 06/01/2025 Commissioner N Y S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 753118816 GCG RISK MANAGEMENT INC 100 CHURCH STREET-SUITE 810 ' NEW YORK NY 10007 ' SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER I CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 6-, 243630 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. _ NEW YORK STATE INSURANCE FUND 4 DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 103973329 IIIIIII IIIIIIII00000001100000994103304III I III lil Forth WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-21606702] U-26.3 64 [00000000000099403304][0001-000021606702][ASZ][35782-06][CertNaP-CERT 1][01.00001] TE CERTIFICATE OF LIABILITY INSURANCE DA2/11/2022"Y' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT The Horton Group PHONE FAX 10320 Orland Parkway Arc a xt:708-845-3000 A/c No): IL Orland Park IL 60467 ADDRESS: certificates@_thehortongroup.com INSURE S AFFORDING COVERAGE NAIC# INSURER A:Evanston Insurance Company 35378 INSURED SUNASOL-01 INSURER B:The Continental Insurance Company 35289 SUNation Solar Systems, Inc.171 Remington Blvd INsuRERc:Axis Surplus Insurance Co. 26620 Ronkonkoma NY 11779 INSURER D:Travelers Property&Casualty Company of America 25674 INSURER E- INSURER F: COVERAGES CERTIFICATE NUMBER:1814587511 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY'BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. I�7R TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP POLICY NUMBER MM/DD MMIDD LIMITS A GENERAL LIABILITY Y Y MKLVlENV103336 2/11/2022 2/11/2023 EACH OCCURRENCE $1,000,000 r COMMERCIAL GENERAL LIABILITY DAMAGE T RENTED PREMISES Ea occurrence $300,000 CLAIMS-MADE OCCUR MED EXP(Any one person) $10.000 PERSONAL&ADV INJURY $1.000.000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000,000 POLICY X PRO- LOC $ B AUTOMOBILE LIABILITY Y Y 7018308202 2/112022 2/112023 COMBINED SINGLE LIMIT Ea accident $1 ODD 000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ 1AUTOS Per accident C UMBRELLA LIAR X OCCUR Y Y P-001-000795195-01 2/112022 2/11/2023 EACH OCCURRENCE $3.000,000 EXCESS LIAR CLAIMS-MADE AGGREGATE $3,000.000 DED I I RETENTION$ $ WORKERS COMPENSATION I WC STATU' OTH- AND EMPLOYERS'LIABILITY Y/NLIM FR ANY PROPRIETOR/PARTNER/EXECUTIVE❑ NIA E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ D Builders Risk Y Y QT-030-2T010874TIL-22 2/112022 2/112023 500,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis With respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and auto liability in favor of the stated additional insureds when required by written contract.Excess follows farm. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718 Building Consultants & Expeditors (631)665-9619 July 6, 2022 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Birenbaum Residence 740 Poquatuck Lane Orient, NY 10.92 KW Rooftop Solar Photovoltaic Systems To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load Without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-10 If you have any further questions, do not hesitate to call. r / K Dunn, RA -PLAN KEY ®-SERICEDISC PROPOSED RESIDENTIAL ❑u^ -SERVICE DISCONNECT PV1.0 COVER SHEET ®-SUPPLY SIDE CONNECTION (EXT) Al-1 PARTIAL ROOF PLAN .-AUTOMATICTRANSFERSWIT°N PHOTOVOLTAIC SYSTEM A1-2' ATTACHMENT SPACING PLAN ®-OAS METER (Exn Al-4 ROOF ACCESS PLAN ®-MAIN SERVICE PANEL Si-1 STRUCTURE ®-suBPANEL SUNATION SOLAR SYSTEMS NYSERDA E1-1 ONE-LINE DIAGRAM ES-SURELESSROUTEH 171 RONKO KOMA, EW YO K 11 INSTALLER 4355 ®-INVERTER RONKONKOMA,NEW YORK 11779 NUMBER E2-1 PV LABELS ®-ENPHASE 1000MBINER G1-1 PV PHOTOS ®-PANEL PHOTOVOLTAIC Birenbaum Residence - E91-ELECTRIC VEHICLE CHARGER \ 740 Poquatuck Lane, Orient, NY 11957 ® ENPHASE ENVOY ®-SENSE CONSUMPTIONMONITOR PRCH/� Drawn By:S. Beattie-07/06/2022 91 AC DISCONNECT r-�II IJ _ -Q-TESLA GATEWAY. S 1 N. i A i -TESLA POWERWALL - 0 \/\]) i �-ENPHASE IO SYSTEM CONTROLLER _ �¢� M�PT - OCCUPANCY OR Q-ENPHASE ID LOAD CONTROLLER 1y1 ELECTRICAL W 1 C = _ ¢ \ .- Ne 19-ENPHASE 1010BATTERY _ e INSPECTION REQUIRE® _� -- USE IS UNLAWFUL ®-ENPHASE IO3 BATTER V Z -18'-VENTILATION Q B•-VENTILATION- -_ A. WITHOUT CERTIFICAT . ®-GENERATION PANEL LL. .. Q-BACKED UP LOADS CENTER ' X, 0 z - _ 0-VENT PIPE T 2 OF OCCUPANCY --EXTERIOR LOCATION / - O Att.Z (20)PROPOSED PV MODULES � W`tCP fi�s_r:'�D I VR P.[i N -1ST FLOOR LOCATION ' .. ¢ —t - Building Review Note BABENiENrLocnnoN Town building examiner has received the enclosed document for minimum acceptable •+-GARAGE LOCATION * f?s m U J7 �'L plan submittal requirements of the town as specified in the building and/or Residential- ode of the State of New York. This review does not guarantee compliance with that D�Jr / code. that responsibility is guaranteed under the seal and signature of the New York PROPOSED PV SYSTEM �4/► ,�(mod State licensed design professional of record. That seal and signature has been interpreted as an attestation that,to the best of the licensee's belief and information Module Type/Qty: (28)SN20-72MBE-390V � the work in this document is:Accurate Module Dimension: 78.03"x 39.45"x 1.57" , [a 6 e [�,d f Conforms with governing codes applicable at the time of submission Conforms with reasonable standards of practice and with view to the safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 49.38 Ibs/2.3 PSF _ 18--VENTILATION V e^ licensee.- Micro Inverter: (28)Enphase IQ8PLUS-72-2-USZ .�r�rloN B•-VENTLATIDN r CGIGi -18--vE System DC Rating: 10.92 kW es�/ � Structural Statement e . The existing structure is adequate to support the new loads imposed by the Estimated AC Production: 12,293 kWh/yr (8)PROPOSEDPVMODULES £.• o photovoltaic module system including uplift and shear. The existing rafter sizes < < i -� - ' and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. Production Source: Aurora PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be (� n n f7 --- ----- --- - — ------ - - --- — ----- -- ---- -- --- -� provided where necessary. An in depth description of each applicable code . l�, II 11J/ AREA RESERVED.FOR AHJ: APPRO ED AS NOTED reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the JUL 1 i Znn DATE: P.# solar equipment. _ 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. BUILDING DEPT. FEE:. BY: 4. Weight of the installed system shall.not exceed more than 5-psf TOWN OF SOUTHOLD NOTIFY,-BUILDING. DEPARTME AT 5. Any plumbing vents are not to f cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN 765-4669:;':8'AM TO 4 PM FOR THE inspection. ; SCALE:N.T.S. FOLLOWING INSPECTIONS: This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential 1. FOUNDATION - TWO REQUIRED Code. FOR POURED CONCRETE PvlmO . ROUGH =.FRAMING & PLUMBINGJOB# 22332: 3. INSULATION COMPLY WITH ALL CODES OF COVER PAGE 4. FINAL CONSTRUCTION MUST NEW YORK STATE & TOWN CODES BE COMPLETE FOR C.O. AS REQUIRED AND CONDITIONS OF ALL CONSTRUCTION SHALL MEET THE REVISION # N/A REQUIREMENTS OF THE CODES OF NEW SUNATI0 N YORK STATE, NOT RESPONSIBLE FOR T G �rn. REVISED BY N/A �_ DESIGN OR CONSTRUCTION ERRORS. Z049BOARD _ SOM TOWN T STEES ---- --- --- DEC . J- RIDGE �, �K. � / • _ _ sj, 029 _ / . . . . ® . . . . • . . .. CIRCUIT 1 /°C// SUNATION • �ENERGY • } • PHOTOVOLTAIC MODULE• sU Re Solar Systems• • �NP� 171 71 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 CIRCUIT 2 COO IN SSTALLEALLE R4355 - N NUMBER JOB NUMBER 3' J GUTTER ROOFAREA ` 22332 29'-5' ROOF 1 301-5" RIDGE CAPPING RIDGE (TYP.) - i 0 ^ _ Z N ■ Q C� Cj n N N LL ?CC N m Z coJ 13'-10" .o Y 1 • • N 'm � m • • ' 0 \ � • • • CIRCUIT 3 GUTTER ROOF 2 16'-10%2" , Attachment Spacing: Portrait Attachment Spacing: Landscape Roof#, -Roof Description Modules Azimuth Tilt Pitch Interior Edge ,Corner Interior Edge Corner 1 Southwest Roof 20 2240 180 4.8/12 48" 3211 1611 6411 64" 4811 3/16"= 1'7-0" 2 Southwest Roof 8 ' 224° 180 4.8/12 48" 3211 1611 6411 6411 48" . . - 1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS (NY)) R324.6 Roof access and pathways. Roof access, pathways and setback requirements shall be provided in accordance with Sections R324.61 through R324.6.2.1. Access and minimum spacing shall be . required to provide emergency access to the roof,to provide pathways (EXT) �C to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. (P Exceptions: (ExT) ,- 9T 029 1. Detached, nonhabitable,structures, including but not limited to detached,.garages;parking shade structures, carports, solar trellises and similar structures, shall not be required to provide _ roof access. 2. Roof access, pathways and setbacks need to be provided where the building official has determined that rooftop - operations will not be employed. _ 3. These requirements shall not apply to roofs with slopes of two // SUNATION units vertical in 12 units horizontal(1 7-percentslope)or less ENERGY [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SUNation Solar systems roof lanes from lowest roof edge to ridge and not less than 36 inches 17t Remington Blvd. p 9 9 Ronkonkoma,New York 11779 (914 mm)wide,shall be provided on all buildings.' Not fewer than one - } (631)-750-9454 pathway shall be provided'on the street or driveway side of the roof. . WTS For each roof plane with a photovoltaic array, a pathway not less than w ROOF s ER 36 ihches 914 mm wide shall be provided from the lowest roof edge -- INSTALLER 4355 ( ) P g cc sus(Bl INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an 0 "= NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. p MSPSS Pathways shall be over areas capable of supporting fire fighters w JOB NUMBER accessing the roof. Pathways shall be located,in areas with minimal LU ^^ ^ obstructions such as vent pipes,-conduit, or mechanical equipment. 22332 Pathways on opposing roof slopes shall not be located along the same c7 18"-VENTILATION " ` plane as the truss; rafter, or other such framing system that supports o 18"-VENTILATION the pathway. LL w Exception: 0 • x 1. Access pathways shall not be required on roof slopes containing LL n photovoltaic modules, panels, or an array where the opposing ACCESS (20)PROPOSED V MODULES Obi a or adjacent roof slope is an access roof. ¢ Z N a O mZ to Access Roof-A roof surface that: H c d o 00 1. Can be accessed from the ground by the fire service. I M m 2. Is capable of providing fire service access to the ridge or peak / O of an opposing or adjacent roof surface that contains l Z =_ m photovoltaic modules,panels,or an array. Ie Cn 3. Is relatively free of vents,skylights,conduits,mechanical H equipment and other such obstructions. o to m 3 4. Does not contain photovoltaic modules,panels or an array;or is 0 a single ridge roof where the maximum edge to edge width of / ACCESS the photovoltaic panel system does not exceed 33 percent of "CEF the ridge length. 18"-VENTILATION [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be ` 18"-VENTILATION located less than 18 inches(457 mm)from a horizontal ridge. 1s" VENTILATION - , I _ Is"-VENTILATION [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels _ -and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape.and rescue opening. (s>PROP SED PV MODULES 13 A pathway not less than 36 inches(914 mm)wide shall be provided to . the emergency escape and rescue opening. 3/32"= 1'-0 A14 ROOF ACCESS PLAN 4 K. Typical Attachment Method ,- 1 RIDGE z O sa�� � ' 11 SNAP'N'RACK ULTRA RAIL PHOTOVOLTAIC 1.9-4 �L-FOOT AND RAIL ASSEMBLY MODULE 3/4"MODULE SPACING BETWEEN ROWS AND (2)S.S.304 5.OMM x 60MM COLUMNS(TYP..) WOOD SCREW FASTENER I T /� SUN/iTl®Ia 1 �l ENERGY RT-MINI ROOF ATTACHMENT I SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (631)-750-9454 RAFTER (1)LAYER SHINGLASPHALT c NYSERLE 4355 • SHINGLE(TYP.) INSTALLER 2" x 10" 24" O.C. // NUMBER JOB NUMBER 22332 PLYWOOD DECKING (TYP.) SOFFIT WOOD FRAMING EXTERIOR (TYP.) WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP" 17'-011 ROOF SECTION (TYP.) o cal - SCALE: N.T.S. T :Z U z (0 O SOLA_ - NOTE: MODULE ME 314"SPACING - •� • �• NDOUMNS MODULE ROWS � I A O ? Roof'# Rafter Size/Spacing Max Span Material Layers Sheathing - T u n n n - - * 5.V _ _ 0 E 1 ` 2 x 10 /24 O.G. 17-0 Composite Shingles 1 Plywood ' . HEIGHT ADJUSTABLE Z m L-FOOT(TYP.) J 2 2"x 10"/24"O.C. 14'-9" Composite Shingles -1 Plywood END CLAMP w co -0 Y U) (TYP.) - F C U SNAP'N'RACK (� m 6.0° ULTRA RAIL m . (TYP-) 0co 3 HEIGHT OFF OF 0— ROOF SURFACE _ Q HT MINI 2 r FYP.) Typical-Module PEST WRAP CUT Side Profile AWAY FOR cwam CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA -'TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW SPEED(MPH.) SPECIAL WINE) W ZONE REQUIRED IND BORNE DEBRIS CATEGORY " TEMPERATURE UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE 1 LOAD EFFECTS D ZONE - WEATHERING FROST LINE DEPTH TERMITE 20 PSF 140 B NO 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE K, r ���\��`��� - v3 J - (P 1 Q� Enphase A/C Branch Circuit(typ.) 120/240v UTILITY SERVICE N Enphase Microinverter(typ.) - - @7 SUNN�T't®N COMBINER Module J-Box(typ.) PANEL SUPPLY-SIDE ,w` /w, ENERGY ✓ CONNECTION I\/' v SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 PV Module(typ.) IN SERDA 4355 EGC Attached To Rail INSTALLER (bp) 200A 1 NUMBER MAIN , J ENPHASE GATEWAY 5 JOB NUMBER (NG leads,monitoring only) ' 2P15A 22332 EnPM1 Gateway , CONDUIT AND CONDUCTOR SCHEDULE-' 2P20A 60A 1 ENPHASE BRANCH CIRCUIT#1 Circuit#1 MAIN J f TAG CONDUCTOR CONDUIT . RUN - ENPHASE BRANCH CIRCUIT#2 Ci cuit#2' v TYPE GAUGE QUANTITY TYPE SIZE LENGTH _L ENPHASE BRANCH CIRCUIT#3 2P2oA 2PsoA 2P20A 1 Enphase Q-Cable 12 6 N/A N/A 15, EGc circuit IQ CombinerSENSE MONITOR ^\\ 2 Type NM 10 6 N/A N/A 30' G G (No bads,moNtoring only I I G —11 MAIN _ n 3 HWN-2 10 6 PVC SCH.80 1.25" 15' 1 2 $ ENPHASE A/C SERVICE u7 IQ COMBINER DISCONNECT PANEL O N GC 8 1 PVC SCH.80 1.25" 15' ROOF- ATTIC EXTERIOR T N SERVICE RATED T O 4 HWN-2 6 , 3 PVC SCH.80 _ 1.25" 10' 4 ENCLOSURE 6 } MIN.100A N Z GC 8 1 PVC SCH.80 1.25" 10, MIN.22kAIC Z 0 O 5 HWN-2 3 3 PVC SCH.80 1.25"• 10' — O a) O 6 GC 6 1 N/A N/A 10' BUILDING ~ 'i GROUNDING N,Q N ELECTRODE M N C N Z cz J m Circuit# PV Module Oty. Micro-Inverter Qty. Maximum AC Operating Current L c cn 1 SN20-72MBE-390V 12 Enphase IQ8PLUS-72-2-US 12 14.52 A N m co 2 SN20-72MBE-390V 8 Enphase IQ8PLUS-72-2-US 8 9,68 A o 3 cz 3 SN20-72MBE-390V 8 Enphase IQ8PLUS-72-2-US 8 9.68 A 0 Maximum AC Operating Current(Total) 33.88 A - E1 = 1 ONE-LINE DIAGRAM LABEL LOCATION:WARNING:PHOTOVOLTAIC LABEL LOCATION: �T CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ Service DisconnectMAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE • • CEILINGS/FLOORS OR MORE THAN 10'URCE . - I DISCONNECT IF APPLICABLE. ICJ �[ of NEC 2017 690.31(G)(3) NEC 2017705.10I • • • • • - • • DisconnectLABEL LOCATION: - — — 0, Tq MAXIMUM• OPERATING SOURCE CIRCUITS: 1 AT EACH'AG DISCONNECT,COMPLETE VOLTAGE AND • -• • 0�— ` � NOMINAL AC OPERATING CURRENT: CURRENT VALUES ON DISCONNECT LABEL. NEC 2017 690.54/NEC 2017 690.13(B) ; NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO I THE BUILDING MAIN SERVICE'DISCONNECT. - PELECFTRIC This building is equipped with-an hL-� �NG - • Interconnected Electric Power � SUN/iTl®Ie1Production Source ENERGY OCK HAZARD _NOT REMOVE SUNation Solar Systems DO NOT TOUCH TERMINALS LBasement"_ ource Type: on Remington Blvd. Ronkonkoma,New York 11779 Photovoltaic t ■ _ _ • _ (631)-750-9454 ` TERMINALS ON BOTH THE LINE Located: Interior. LOAD SIDES MAY BE ENERGIZED Located Service in Main Panel Garage:_ Exterior.— NYSERDA 4 3 5 5 IN THE OPEN POSITION - Rear._ LHSide:_ P • • . INSTALLER PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGEther Location:, NUMBERWHENEVERTHEYAREENPOEDTOSUNLIGHT - n Solar Systems '1750-9454 JOB NUMBER w.sunation.com SHUTDOWN ED. LABEL LOCATION: _ --- I SOLAR SYSTEM EQUIPPED. 22332 - _ WITH RAPID SHUTDOWN _ ,• 1 AT PRIMARY DISCONNECTING MEANS FOR THE PV ARRAY ON EXTERIOR WALL j TURN RAPID SHUTDOWN 'r NEC 2077 690 SWITCH TO THE 'OFRPOSITION TO wv nssR° SHUT DOWN PV SYSTEM - AND REDUCE SHOCK HAZARD IN THE ARRAYLO - 0 N T N - r- o �- N U Z. o J z0 N o F SD 0 o Z � J co N (D _ p co aco J O E2=1 ' PV LABELS + ` SUNATION SUNation Solar Systems 171 Remington Blvd. y Ronkonkoma,New York 11779 (631)-750-94-54 + .._ NYSERDA r r INSTALLER 4355NUMBER y. JOB NUMBER 22332 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF - � N s — r N p U _ C CIA o r p cz r unr.C z J m cz N U Z 0 SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G1 =1 - - PV PHOTOS 0`g'�gip, L K, �w A � i I 4 O� i Enphase A/C Branch Circuit(typ.) lzoizaov UTILITY SERVICE Enphase Microinverter SUNATION COMBINER suP`LSIDE M `S Module J-Box(typ.) PANEL CONN'ACTION 1 1 1 Y 1 SUNation Solar Systems J f ' 171 Remington Blvd. Ronkonkoma,New York 11779 ' (631)-750-9454 PV Module(typ.) NYSERDA EGC Attached To Rail 1 200A 1 INSTALLER 4355 (typ.) J MAIN NUMBER ENPHASE GATEWAY ' JOB NUMBER (No loads,monitoring only) '\ 2P15A 22332 fu E•pu Ga—, CONDUIT AND CONDUCTOR SCHEDULE 2P20A 60A ENPHASE BRANCH CIRCUIT#1 Circuit#1 MAIN TAG CONDUCTOR CONDUIT RUN zazoA ENPHASE BRANCH CIRCUIT#2 I Circuit#2 TYPE GAUGE QUANTITY TYPE SIZE LENGTH J - ENPHASE BRANCH CIRCUIT#3 21`20a 1 Enphase Q-Cable 12 6 N/A N/A 15' EGC�','I Circuit 2P60A 2P20A 1, IQ Combiner Sense \ L Type NM � � � ENSE MONITO (� 10 6 N/A N/A 30' j G I (a No loads, ' l �^ MAIN �' ENPHASE I A/C SERVICE LO 3 HWN-2 10 6 PVC SCH.80 1.25" 15' :1 2 3 IQ COMBINER DISCONNECT `, J GC 8 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR PANEL T O 4 HWN-2 6 3 o- PVC SCH.80 1.25" 10' SERVICE RATED ENCLOSURE � N GC 8 1 PVC SCH.80 1.25" 10' `41 MIN.100A 6� U Z 0 .1 MIN.22k AIC Z 5 HWN-2 3 3 PVC SCH.80 1.25" 10, — O N O 6 GC 6 1 N/A N/A 10, BUILDING V) 0 GROUNDING ELECTRODE IM X 6 ','+ C (D Z � CV J m Circuit# PV Module OtY• Micro-Inverter Qty. Maximum AC Operating Current F _ U) 1 SN20-72MBE-390V 12 Enphase I08PLUS-72-2-US 12 14.52 A N �' m C m 2 SN20-72MBE-390V 8 Enphase IQ8PLUS-72-2-US 8 9.68 A o 3 SN20-72MBE-390V 8 Enphase IQ8PLUS-72-2-US g 9.68 A o Maximum AC Operating Current(Total) 33.88 A E1 = 1 ONE-LINE DIAGRAM r /i ` ORGY SYSTEMS /24.6 Roof access and pathways. Roof access, pathways and �t� �� L ® � ,ck requirements shall be provided in accordance with Sections A.61 through R324.6.2.1. Access and minimum spacing shall be .squired to provide emergency access to the roof,to provide pathways (EXT) ,,'to specific areas of the roof, provide for smoke ventilation opportunity _ i areas and to provide emergency egress from the roof. -� Exceptions: (ExT) -- ozs 1. Detached, nonhabitable structures, including but not limited to detached garages, parking shade structures, carports, solar trellises and similar structures, shall not be required to provide roof access. - 2- Roof access, pathways and setbacks need to be provided where the building official has determined that rooftop operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two units vertical in 12 units horizontal(1 7-percent slope)or less SvN ,�,1, � ENERGY N R324.6.1 Pathways. Not fewer than two pathways, on separate [ Y P Y P SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches A 171 Remington Blvd. (914 mm)wide,shall be provided on all buildings. Not fewer than one Ronkonkoma,New York 11779 pathway shall be provided on the street or driveway side of the roof. . ¢ (631)-750-9454 For each roof plane with a photovoltaic array,a pathway not less than W MTS AooF 36 inches (914 mm)wide shall be provided from the lowest roof edge >_ sue " s NYSERDA /� 3 5 5 to the ridge on thee same roof plane as the photovoltaic array, on an p -- (e) -: INSTALLER(�, adjacent roof plane, or straddling the same and adjacent roof planes. Ir o MSP- NUMBER Pathways shall be over areas capable of supporting fire fighters AC JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal ¢ osc obstructions such as vent pipes,- conduit, or mechanical equipment. CD ^^ n Pathways on opposing roof slopes shall not be located along the same z -- -18"-VENTILATION L L L plane as the truss, rafter, or other such framing system that supports Is"-VENTILATION the pathway. Exception: 0 1. Access pathways shall not be required on roof slopes containing 11- photovoltaic modules, panels, or an array where the opposing 0Ass 0� (20)PROPOSED V MODULES i j or-adjacent-roof-slope-is-an-access-roof. z N Q ! N LL Z N Access Roof-A roof surface that: O m z W H o m � n a o 1. Can be accessed from the ground by the fire service. > y� 2. Is capable of providing fire service access to the ridge dr peak (D of an opposing or adjacent roof surface that contains - LLO E ai co- m photovoltaic modules,panels,or an array. Z„ > W c m 3. Is relatively free of vents,skylights,conduits,mechanical Y T equipment and other such obstructions. .. N m o m 4. Does not contain photovoltaic modules, panels or an array,or is 0 3 o a single ridge roof where the maximum edge to edge width of the photovoltaic panel system does not exceed 33 percent of \ 1 y A oFs n the ridge length. I r r ' 18'-VENTILATION [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be , 18"-VENTILATION „. located less than 18 inches(457 mm)from a horizontal ridge. 18"-VENTILATION -18"-VENTILATION [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. (a)PROP SED PV MODULES— .� A pathway not less than 36 inches(914 mm)wide shall be provided to i the emergency escape and rescue opening. i -- -- 3/32"= 1'-W A1 =4 ROOF ACCESS PLAN i Mai SUNATION ENERGY May 20, 2024 Solar Permit Amendment - BF#48202 *4� 740 Poquatuk Lane, Orient, NY 11957 �'YD a� T Dear Susan and Lisa, Enclosed are'the updated system draw-in gs.for the add-on solar system for our clients Birenbaum and Roman. They are adding (17) panels to the existing (28) panel system. Please amend existing permit#48202 to reflect these additional panels. Please call me with any questions and when the amended permit is processed. Best regards, Evelyn Polvere Permit Manager office: 631-750-9454 ext. 346 cell: 631-459-6202 epolvere@sunation.com ■ -HSH 1-11 REMINGTON BOULEVARD WWW.SUNATION.COM RONKONKOMA, Graham Associates 256 Orinoco Drive, Suite A Dright`vaters, NY 11718 Planning & Design (631)665-9619 May 20, 2024 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Brienbaum Residence 740 Poquatuck Lane Orient, NY Proposed 6.8 KW PV Rooftop Solar System added to 10.92 KW PVSystem To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. ®Ap�'yi Si \ L K,0 0299 Mich IQ�� PLAN ®-SERVICDISC �Q PROPOSED RESIDENTIAL /� a-SERVICE DISCONNECT PV1-O C T ®-SUPPLY SIDE CONNECTION (EXT) A11-1 TI R N -AUTOMATICTRANSFERSWITCH A D D - 0 N PV SYSTEM ER A1-2 CHMENT SP PLAN B-GAS E ERV At- ROOF A CESS N ®'MAN SVtCE PANEL Exr) -1 TURE ®-SUB PANEL SUNATION SOLAR SYSTEMS NYSERDA 4355 ®-WIRELESS ROUTER 171 REMINGTON BOULEVARD INSTALLER 1-1 � -LINE DIAG M RONKONKOMA, NEW YORK 11779 NUMBER ®-INVERTER 1 PV LA ®. ENPHASE 10 AMENDMENT Birenbaum Residence ®-PANEL PHOTOVOLTAICOVOLTAIC AMEND M ,``���• A� Q-ELECTRIC VEHICLE CHARGER 3 740 Poquatuck Lane, Orient, NY 11957 �G'A V ®-ENPHASE ENVOY Ir Drawn By: J. DellaRocca- 05/17/2024 SENSE CONSUMPTION MONITOR ®-AC DISCONNECT O -TESLA GATEWAY ¢ AT ;ep ED qR ®-TESLA POWERWALL Z SIIB(8 Ac Agg -ENPMASEIO SYSTEM CONTROLLER U MSPS Ar ��� NE� ifAc'Si�, ©-ENPHASE IQ LOAD CONTROLLER W � (1])Pf10POSED PV MODULES LU Z -4 0-ENPHASE 10 10 BATTERY 0 t►� S ION ENPHASE ®-ENPHASE 10 3 BATTERY LLO •18'-VEMILATION ®-GENERATION PANEL Z ®-BACKED UP LOADS CENTER ¢ /l —^ c A 0-VENT PIPE98117 O�� m-EXTERIOR LOCATION \� / m^ (20)EXISTING PV MODULES O ^^'' ^-1 ST FLOOR LOCATION - \ Building e t BASEMENT LOCATION - --- — Town building examiner has received the enclosed document for minimum acceptable GARAGE LOCATION plan submittal requirements of the town as specified in the building and/or Residential -- Code of the State of New York. This review does not guarantee compliance with that code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal and signature has been PROPOSED PV SYSTEM / interpreted as an attestation that,to the best of the licensee's belief and information th e work in this document is: Module Type/Qty: (17)SL65-546HJ 400V "AWF Accurate Module Dimension: 67.8"x 44.85"x 1.18" / 0 Conforms with ssion • Conforms with reasonable standards of practice es applicable at eand with time of view(to the safeguarding of life,heath,property and public welfare is the responsibility of the Module Weight/PSF: 47.18 Ibs/2.23423210110397 PSF " Fs poop IW-VENTILATION licensee. -1W-VENTILATION Micro Inverter: (17)Enphase IQ8PLUS-72-2-US VENTXATIIry -IB"-VENTILAT-D4 Structural Statement System DC Rating: 6.8 kW �, ``� • The existing structure is adequate to support the new loads imposed by the System AC Rating: 4.9368 kW/AC /, D photovoltaic module system including uplift and shear. The existing rafter sizes Aurora Estimated AC Production: 5,934 kWh/yr ,B,EXISTING PV MODULES— and dimensions conform to RC-NYS 2020 table R802.4.1(1)-Rafter Spans. PV Notes 1. This PV system has been designed to meet all current and applicable fire EXISTING PV SYSTEM prevention setback pathways per 2020 NYS residential code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be Module Type/Qty: 28)SN20-72MBE-390V - -- --- - ---- -- - provided where necessary. An In depth description of each applicable code reference and exception for any codes is depicted on the PV-1 plate of this Module Dimension: 78.03"x 39.45"x 1.57" drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the Module Weight/PSF: 49.38 Ibs/2.3 PSF solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more Micro Inverter: (28)Enphase I08PLUS-72-2-US than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf System DC Rating: 10.92 kW 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and System AC Rating: 8.1312 kW/AC inspection. FULL HOUSE ROOF PLAN Installed by: SUNation Solar Systems SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-10 and the 2020 New York State Residential Code. PV1 = I OB# 02926 COVER PAGE REVISION # N/A SVNATIOI ENEhim i REVISED BY N/A SOLAR ENERGY SYSTEMS (NY) R3?4.6 Roof access and pathways. Roof access, pathways and S'�FRED setback requirements shall be provided in accordance with Sections R324.61 through R324.6.2.1. Access and minimum spacing shall be ® G Et �( 0 required to provide emergency access to the roof,to provide pathways l to specific areas of the roof, provide for smoke ventilation opportunity G areas and to provide emergency egress from the roof. * Z IQ L LE Exceptions: (EXT) - 1. Detached, nonhabitable structures, including but not limited to detached garages, parking shade structures, carports, solar 'ANENE trellises and similar structures, shall not be required to provide W�O roof access. 2. Roof access, pathways and setbacks need to be provided where the building official has determined that rooftop operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two a SUNATION units vertical in 12 units horizontal(17-percent slope)or less 3 w SUNation Solar Systems [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate Ir roof lanes from lowest roof edge to ridge and not less than 36 inches 171 Remington York 1 p g g O Ronkonkoma,New York 11779 (914 mm) wide, shall be provided on all buildings. Not fewer than one (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. Lu ATS For each roof plane with a photovoltaic array, a pathway not less than c 1— ROOF NYSERDA 4355 36 inches (914 mm)wide shall be provided from the lowest roof edge SUB (B ccEse INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an z == S 36 NUMBER U MSP adjacent roof plane, or straddling the same and adjacent roof planes. a =c Pathways shall be over areas capable of supporting fire fighters " 6'c JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal (17)PROPOSED PV MODULES obstructions such as vent pipes, conduit, or mechanical equipment. 0 02926 Pathways on opposing roof slopes shall not be located along the same O -18"-VENTILATION plane as the truss, rafter, or other such framing system that supports O 18"-VENTILATION __. the pathway. z Q Exception: LL _ -._} ......... ._ I \ 1. Access i shall not be required on roof slopes containing pathways q P g (20)EXISTING PV MODULES L P P Y opposing ACCESS' rn N photovoltaic modules, panels, or an array where the o osln ROOF j � T o or adjacent roof slope is an access roof. O a) z Access Roof-A roof surface that: H Q 0 co 1. Can be accessed from the ground by the fire service. __ l _..._ Q o 2. Is capable of providing fire service access to the ridge or peak 0 LL £ c r of an opposing or adjacent roof surface that contains Z :3 a� photovoltaic modules,panels,or an array. --- LU 3. Is relatively free of vents,skylights,conduits,mechanical � � T equipment and other such obstructions. ACCESS N C° Q m 4. Does not contain photovoltaic modules, panels or an array,or is ROOF °a 3 a single ridge roof where the maximum edge to edge width of the photovoltaic panel system does not exceed 33 percent of r the ridge length. Access ACCESS ROOF ROOF -18"-VENTILATION [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be 1a"-VENTILATION located less than 18 inches(457 mm)from a horizontal ridge. 18"-VENTILATION -18"-VENTILATION [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion 1> _j of the roof that is below and emergency escape and rescue opening. �i� o A pathway not less than 36 inches(914 mm)wide shall be provided to the emergency escape and rescue opening. (e)EXISTING Pv moouLEs i i 3/32" = V-0" A1 =4 ROOF ACCESS PLAN Typical Attachment Method 41lERSo HAEL,rr�0 � Zm z 0 RIDGE SNAP WRACK ULTRA RA �O T O VOLTAIC 191-4° �L-FOOT AND RAILASSE �MB �OF 9�17 PH MODULE EW YD 314" MODULE SPACING BETWEEN ROWS AND (2)S.S.304 5.OMM X 60MM COLUMNS (TYP.) WOOD SCREW FASTENER SUNATION RT-MINI ROOF ATTACHMENT SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (631)-750-9454 RAFTER (1)LAYER ASPHALT o NYSE NUMBERRDA 4355 O.C.X 10 24" iSHINGLE(TYP.) INSTALLER / JOB NUMBER 02926 PLYWOOD DECKING (TYP.) SOFFIT WOOD FRAMING EXTERIOR (TYP.) WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP" - -- - 17'-01 -- 00.1 ROOF SECTION (TYP.) 0) CD T O SCALE: N.T.S. r W Z �^ Z C r--; SOLAR MODULE FRAME O Q) NOTE:3/4'SPACING I— �_ •� CL) BETWEEN MODULE ROWS Q (n Y U Roof# Rafter Size/Spacing Max Span Material Layers Sheathing T AND COLUMNS. ¢ 1 0 1 2"X 10" 16" O.C. 171-0" Composite Shingles 1 Plywood 55" HEIGHT ADJUSTABLE O E (z L-FOOT(TYP.) ? D J END CLAMP W Cz - 0 (TYP.) H U SNAP'N'RACK (Z 6.0" ULTRA RAIL [Q Z3 m 1 (TYP.) CT 0 o >� HEIGHT OFF OF IZ > ROOF SURFACE � (1$ ,It0 FIT MINI2 I- (TYP.) Typical Module PEST WRAP CUT AWAY FOR Side Profile CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER - SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE UN ENT FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE LOAD S 1 1 SPEED(MPH.) EFFECTS ZONE SPECIAL WIND ZONE WEATHERING FROST LINE DEPTH TERMITE REQUIRED 20 PSF 140 B YES 2 B SEVERE 3'-0" MODERATE TO 15 DEG WA SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE Gas ERFpq A A t 'ro s * G a is f- -f m r Z 0 �t 1 Enphase A/C Branch Circuit (typ.) UTILITY SERVICE Enphase Microinverter(typ.) — ^—' — — Existing COMBINER PSEG Utility Meier n n SUNATION 20261 Module J-Box(typ.) PANEL A�Meter #969830655115 I V' 120/240v SUNation Solar Systems SUPPLY SIDE CONNECTION 171 Remington Blvd. Ronkonkoma,New York 11779 PV Module(typ.) (631)-750-9454 NY A EGC Attached To Rail(typ.) i /`J 200A INSTALL DER 4355 MAIN NUMBER CONDUIT AND CONDUCTOR SCHEDULE ENPHASE GATEWAY JOB NUMBER TAG CONDUCTOR CONDUIT RUN (No loads,monitoring only) (� TYPE GAUGE QUANTITY TYPE SIZE LENGTH 2P2OA 2P15A 02926 Circuit#1 Eq;-a.aw.r.y EXISTING EXISTING ENPHASE BRANCH CIRCUIT#1 Circuit 70A 1 Enphase Q-Cable 12 6 N/A N/A 15' EXTENDED ENPHASE BRANCH CIRCUIT#2 MAIN 2P20A 2 Type NM 10 6 N/A N/A 30' EXISTING ENPHASE BRANCH CIRCUIT#3 Circuit#s PROPOSED ENPHASE BRANCH CIRCUIT#4 2P20A Combiner 2P2De 3 HWN-2 10 6 PVC SCH.80 1.25" 15' � � � � Circuit#4 IOCombiner Sense GC 8 1 PVC SCH.80 1.25" 15' �`j SENSE MONITO EGC G G INo oaa:,moa tonag«+r G � � MAIN to NPROPOSED 2` ENPHASE A/C SERVICE to 1 Enphase O-Cable 12 2 N/A N/A 15' ROOF ATTIC EXTERIOR IO COMBINER DISCONNECT PANEL CD 2 Type NM 10 2 N/A N/A 30' SERVICE RATED 4' ENCLOSURE �- 3 HWN-2 10 2 PVC SCH.80 1.25" 15' MIN.60A J Z 4 HWN-2 4 3 PVC SCH.80 1.25" 10' MIN.22kAIC Z Ln 0 O Q) r GC 8 1 PVC SCH.80 1.25" 10, DISCONNEERIOR ANS BUILDING Q -0 '� U 5 HWN-2 3 3 PVC SCH.80 1.25" 10' GROUNDING 2 (1) O ELECTRODE O 6 33EC 4 1 N/A N/A 10' LL E c M Circuit# PV Module Oty. Micro-Inverter Qty. Maximum AC Operating Current UJI Y m � v 1 SN20-72MBE-390V 12 Enphase IQ8PLUS-72-2-US 12 14.52 A N m ICY m 2 SN20-72MBE-390V 8 Enphase I08PLUS-72-2-US 13 15.73 A a SL65-54BHJ-400V 5 CD 3 SN20-72MBE-390V 8 Enphase I108PLUS-72-2-US 8 9.68 A 4 SL65-54BHJ-400V 12 Enphase IWLUS-72-2-US 12 14.52 A Maximum AC Operating Current(Total) 54.45 A E1 = 1 ONE-LINE DIAGRAM PHOTOVOLTAIC AC DISCOli`i� LABEL LOCATION: LABEL LOCATION: �G\c AEEoq�S' MAXIMUM AC OPERATING CURRENT SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Service Disconnect MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE �\ n_C CURRENT VALUES ON DISCONNECT LABEL. DISCONNECT IF APPLICABLE. NOMINAL AC OPERATING CURRENT m 10 5 NEC 2017 70 . NEC 2017 690.54/NEC 2017 690.13(6) 07Sec i • • Disconnect WARNING - - c ELECTRIC SHOCK HAZARD NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO DO NOT TOUCH TERMINALS Primary Service Disconnect • - 1114 THE BUILDING MAIN SERVICE DISCONNECT. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED Service Panel This building is equipped with an IN THE OPEN POSITION • • in Main Interconnected Electric Power `✓ SUNATION PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE Production Source `J WHENEVER THEY ARE EXPOED TO SUNLIGHT DO • REMOVESUNation Solar Systems Source Tyne: 171 Remington Blvd. Solar Photovoltaic Ronkonkoma,New York11779 (631)-750-9454 Disconnect is Located. Interior.. Basement: Garage. Exterior. NYSERDA 4 3 5 5 Front:_ - Rear. LH Side. INSTALLER R'1 Side: Other Location: NUMBER SUNation Solar Systems SOLAR SYSTEM EQUIPPED JOB NUMBER 631-750-9454 www.sunation.com WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN 02926 SWITCH TO THE PHOTOVOLTAIC "OFF'POSRKMI TO rro as SHUTDOWN PV SYSTEM EQUIPPED WITH WID AND REDUCE THE SHOCK HAZARD SHUTDOWN IN ARRAY LLI LO N O O T C\I T T Z Z U LO O 1 a� Q -0 ` U O U O LL E Z C J N W � Y � H � U N a) m 0 O O Cz E2= 1 PV LABELS GAS i EREpq • \ �tAEt 'C) z m 817 I 1HIfl111(lf =, ` SUN ION - -" SUNation Solar Systems 171 Remington Blvd. - -� _ Ronkonkoma,New York 11779 � (631)-750.9454 NYSER DA435 INSTALLER 5 NUMBER JOB NUMBER 02926 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF L _rn 0 t I O CC aj u- E c1s _ J — _a Y c ' - N _ O 1 C SOUTH VIEW EXISTING PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G1 = 1 PVPHOTOS E rxaxxm', r, 'b Y •""""`. ,.`" :' r'"` -a�++r.: �."F�€a' �€ � '�:n"a£:'F"'`d """ ""i .."„x"", .."s. ".....',-, ..,.� ; Y �"�'3ei� '�'3x •� 'a.'s a'v< s" e Fk\,':::r� I,. ;; x .q €.g _ � i3 \'� 's•3', €s d.+kSF :�.a� € ...:�,a m�F ;X�°3 ,�,r� g �: '°� � �s...s, F"r� `�`�`s'�`�,&•rx.. "�.�, \ z= �'� `� �t� .� `3�a€nF � �a�a, :: r a%s.-'6' �r §s''n � >r;�,��3�^ >>�"� G a ��.ua�,..us� '�&e x `, s ems,."•ka szw.»>. ws�'�,. `�.�,x.• S�,„�.��t' `'k 3s`"�.x.�'��..: t;"�F'� �'�'�` 2 �. s?��,� �F i �. i.k„` •,,,sa s. ,� €� +h"5 a �I >`''� .,°1va. y `'`���- ���k..2• \ "�i�+n*�s .�r� "�`. �`�3;. �,�` ti er`�\� �• .���� .3�+�a � �a FEATURES®� Enhanced External Load/Impact IN� Snow Load:5,400 Pa Wind Load:2,400 Pa Fire Safety Spread of Flame Class A Burning Brand Class C PID Resistance Enhanced Potential Induced Degradation ® UP l Resistance Higher power output 0—+5Wp Higher than rated power ��1111 01r W I� Excellent performance under ® � low light conditions Cloudy days,mornings and evening Various Options Available El Black or Silver Frame WARRANTY CERTIFICATIONS 12-years Product Warranty IEC 61215,61730/UL 61730 25-years Linear Performance Warranty ISO 9001 :Quality Management System ISO 14001 : Environmental Management System 100 S-Energy's Linear Performance Warranty OHSAS 18001 :Occupational Health&Safety System 4 s " o ----------- ------- i> ss J z CE w s" a .>4�ic'r .:xr '�i e�„3" ❑ C us .....:::. .......,. .......: ..'.a o s 10 is zo zs hdu y Suxd Id i:�� ��:i� e �� a� ��``�nr1� F x ��� '�.� � ."'i �k s ''3 a• 's �' �v�s�v c 3.� �' e� � �s �s'e r` R t' � .l' :iv F �"eeo�n'FY(��✓.rf���l�' �*� �� �� ..:kr ny..E:.��ic� � w� ,y�y5'�po 3i;3` ,�:} >• � a�� �"�n�'�j'a�� �L e'�x �•s�' ........... �r��F I.� Yt \���� �� ,:� ���,�.. \F�� �,�? .�.;',. ��. € r�� i�n��� ���1 5�:�� ;r.:' �. � � ;s ��'• � �>�g �3 F ;w „4 ,. §� s�;.,-,.� <<..�•, .x.,. ::.. � s .�, a � t ,� ,�; € ...:'„�$,��Fw_ss.�...a�:':w •,.:w,..:.>..�.�• � d�ww� ..� „ems, t�v��'s, �'a r. ('was IV20-72MAENBENCE 1,000v � = S-Ener9Y 385W•39OW•395W Monocrystalline PV Module •a�.'.,r"�'w.�'.mrri"�"';".�.;,•�..•• i tix"'i..:,ck,,:'&a%�i:A�"�"„'".. •'-'"�m:,...."a..�:eaw% 'nxu,�x;,�,:,�;,,,..:,:..k,.,::a::. •�w ..,,. .:.,m.......,.. .,.e;,..c�,a.�i:�'.�.x�."•2.xt�"'��*iw":&a�^"a�.�"'kM:a'��+"s' ^�"�vx�E3si?'v°'..'nL ELECTRICAL CHARACTERISTICS STCrU:a +oaown f anm he.°w.w�sr A+a+'sa 3N1p i2tvWE/MBE/MCE 385V SN10 72iiMAEJMBEJMtE 390N SN1012MAE/MBE/MCE395V Rated Power(Pmax)Power 385W 390W 395W Voltage at Pmax!Nmp)• 4t).2V 40.4U ,. 4D.6V Current at Pmax(Imp) 9.58A 9.66A 9.74A Warranted Minimum Pmax; 385W 3901N 395W Short-Circuit Current(Isc) 10.09A 10.18A 10.27A Opel-Circuit Voltage(Voc) 48.7Y 48,9U 49.1U Module Efficiency• 19.39/0 19.64% 19.89% Operating Module Temperature 40°C"to"+85*4c Maximum System Voltage 1,000V Fuse Rating 26A Maximum Reverse Current 27A Power Tolerance• MECHANICAL CHARACTERISTICS Junclion box 10x10 i0.39x0.39: _ — ...._............--....._..._. _..... ........_ Solaf;Celis j Monocrystalline Cells 158.75x158.75mm Orsinoge hies l 1 4 p'.ccz t Numberaf Cells 72 Cells(6x12 Matrix) t 1:09(0,554,35)j Drm2nsions 1,982 x 1,002 x 40mm Ftoc: ir:Place ect i� Frartt t oad 5 40oP, € Rearl oad 2,400Pa Weight a 22.kg Fronf'Glassj 3.2mm High-Transmittance Low Iron Tempered Glass �6 i0.24 M E " 9 pi od Frame Anodized Aluminum Frame(Silver!Black) 2 place i — i Box IP68 with 3 bypass diodes Outpuf Cables PV W re{PV1-F),1?AWG(4mm�,Cable Length:90omm ` t ` Connectors MC4 Compatible TEMPERATURE CHARACTERISTICS 952r37e��........ : ............................_._........ TBmperature coefficient of Isc 0.05%!°C ._..._..__......._........_......... _ { ....._......_.._......_... i EDWINA) Temperature coefficient of 5loc 029%/°C Temperature coefficient of power' 0.39%/°C NOG'f(TatrZu C•,�irramance ao4ri/m�;Wind lmrsi �� 45±2°C '- PACKING CONFIGURATION , Container 2q 44` nv ns Modules Per Pallet 27pcs 27pcs i Modu / %P Per Container 10pallets 22palets oM .._.,........................... o o -. Modules Per Container 270pos 594pcs , ° vom�eN b ° 0 v ug v Pmax measurementWeIrance:t 3°h• installation instruction pupplied.Wilhjhe module must be S-Energy uses triple A class simulator, duty falldi ied.Forfurther information which is not REMARK$ NOTES mentioned on installation guides or directions,please - Specf cation suhjectto change without prior notice. ' contactto'aurtechnicsi service department.. S-Energy reserves the rights Of final interpretation E mai(:'inquiry@s energy,com"• Yt>� t�x, y. � >c�`� ; : �.``�vt �� �"� 3 r C ����� ��ti��� `' ?` \��°�,���E'•� 6��h���•��€�������� gas x'��" ENPHASE. m m IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling Enphase F High productivity and reliability �i Z5 Produce power even when the iyear limited grid is down warranty • More than one million cumulative Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest L_ SAFETY advanced grid support Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements 1 Q8SP-DS-0002-01-EN-US-2021-10-19 IQ8 and IQ8+ Microinverters INPUT DATA 1 .1 i.. Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currentz[module]so] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1 1: O: Peak output power VA 245 I 300 Max continuous output power VA 240 IJ 290 Nominal(L-L)voltage/range3 V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20.A(L-L)branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -400C to+60°C(-40°F to+140°F) Relative humidity range 49/o to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.Seethe compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IOBSP-DS-0002-01-EN-US-2021-10-19 SERIES 100 FLASHED L FOOT SnapNrack PV Mounting Systems The SnapNrack line of solar mounting systems is designed to reduce total y` � �rY ,� �� 44, . installation costs. The system featuresu > technical innovations proven on more than 20OMW of solar projects to simplify installation and reduce costs. r� < Flashed L Foot Simplified " U SnapNrack Series 100 Flashed L Foot Kit is an innovative 5' K solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a '` single fastener flashed to an attachment composition Flashed L Foot in 3 Simple;Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place-order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact . SnapNrack- Patent Pending FW @UhU ng _._._.__.. -� i Flashed L Foot Kit Assembled(1°spacer sold separately) Flashed L Foot Kit Parts(1"spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions ,-SNAPNRACK CHANNEL NUT )/ rSNAPNRACK 92 DEGREE L•FOl3T,CLEAR ,-5/1613 FLANGE NUT y f -5/1613X lIN BOLT WITH J� SPLiT LOCK WASHER -SNAPNRACK COMPOSITION FLASMNG 8 3.13 \-SNAMACK L-FOOT BASE SnapNrack Flashed Foot Technical Data Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack! PV MounUng Systems (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. SERIES 100 UL ROOF MOUNTSYSTEM SnapNrack •lar Mounting Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. ; Pitched Roof Arrays Simplified --'- --� The SnapNrack Series 100 UL Roof Mount System r is an efficient,visually appealing, photovoltaic (PV) module installations stem.Series 100 UL is Listed --- to the UL Standard 2703 for Bonding, meaning that I s:Ste Simple in 4 stem f S all system components have been Certified by UL for Roo Y p p electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware. The System's components provide Tool (configure.snapnrack:com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, i and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height,'Roof Type, Wind and Snow Loads) i the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of" Materials.. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Bolt with Split- Splice Insert Split-Lock Washer Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base <' Mid Clamp SnapNrack SnapNrack Bonding Bonding SnapNrack Adjustable End Bonding Stainless Channel Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG ---- - - - Copper Wire - ' SnapNrack Ground Lug -— — Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap C4— UECWedge Stainless Steel Bolt with Flat Washer IV IF IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding19 Standoff 1 �� Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber _ Steel Flange Nut Bonding Channel Nut Channel •+kF ainless Rain Collar Serrated Stainless Nut a Standoff nge Nut SnapNrackSteel Flange Bolt SnapNrack Stainless Flan pox Mill Finish 92 Degree g L Foot Bolt SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(I-Hole SnapNrack Base Shown) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding L SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Foot SnapNrack Series 100 UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. &Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved. L'�/ 0 0 4(Mow ° o !Hum IRmRRII"IRORmMlNd IMMUE IIHMIalm11ENINIllmii a a ©o' : HNNIN111�INlNiBmIIBdBmNIIBdIINNmBNNINd NRNINIIHIINNIIIHIIIINIIIImm1NI�IIdN111RIIINIII HR o m ingeImHRIR11HH1111 I1 HUNN �11 N I NIIIIll Im mmlin ImmmdHII IIIImNNIINI in IIH I Hlmll IHHmHBNIB,@ HIIII NI IHHIIHHIB ISBNNIIIIIIl IRHI i1IHi NR mmHIPHIIHIRE NIHIImi um IN IIRIHHIImRiIHHIH1Rl mHle H I I HNI HHmRIBI1mHH 1111111111110 HI�IIHlIIIHIINI111mIIN1N1 111111E HRmI�IINRo I10III dN Ipnil I IHI�INI R ml IIIIII11111R IiIgIII IIII land lull RHmIINm01111NIVI111�1111 IN IIII mIIHi Idl IIIII III�IN IIRIIII�llll lmd NRII�ImIRIImIRIHRIdmRRNIP oil HE Im .ImIII�I H�pRR ImRIHIIgIRAmIIRNNNd �o 0 o a o . HIIIImRImRImR�Im�HlmmdARRNmHRmRH IRRRmIdHmIRIHImR(�IHRNRmdmNRHHRI�IA NHMII miimIIIIHmo mIImImIHHHIHIHHHH mIHIHIIHIINIINIIIIIIlH!IIIHNIINiHIIHIIHIINN III • °- Hmp1�m1MR 1HImim1HIIIIRIdHImINH IINIRRIIHIIlNINIHIIIINN1H11mmIdIIHHmHmIRm • o o s o o- m . G . - �IIH�mimilm 111HiNmHNHNmm0lm HmmmHmlBmHHHNmHm�IHmmm�II mmINmlHHmm�NBmBNmIHHHmH HmmmmRlmNmmmN®HmiHRRRmmlmml lmHmHHmNImHlHmm®R MillHR® Blll®I mmHm®mOH®®NII HQNmB�HB®mml®B BOB u�n 17911 r—� r r n r r a�r- FEATURES { l :1 ii 1 �111 ` 1 Im .'I19. il k, Ir �:ll it it l,; i Up to 25%more energy yield due to the back side power generation Low LID mono PERC Bloomberg.1 0 I� ^NEW EhTNGY Flti,WCEJ� ?� �� Fo C E CPbifacial cell technologycus W-i Excellent performance under low light conditions WARRANTY Cloudy days,mornings and evening -YEARS PRODUCT WARRANTY Enhanced External Load/Impact �i -YEARS LINEAR PERFORMANCE WARRANTY _ Snow Load:5,400 Pa 6 Wind Load:2,400 Pa O°* 71 PID Resistance 94- Enhanced Potential Induced Degradation 9"2 S f _ Resistance r Fire Safety Spread of Flame Class A Burning Brand Class C o, s o s zo =s so l S-Energy Industry Standard I; 4� C�STN��. , cif o o��y�/�y n n�2 n� - • � d� o - p A 2 U�wY,m now- mm,uc��y�b��,,�.,._.,���.�,„ �/ I I �� �`^°� lt' �"'°'°r l-° � LS'rru�.�t�:ln�luw�P/ 0 1 {n.o •o"_- o 0 0 0 • 0 0 0 a o- o • o .o. utrmE�G :i GQ(� �: 0 4�9g o o c o�,o .o. � �,® v111111 i.v✓ r ■ 9-01-+i I.J1 9 SyssSJ-cnery.Y 19500V Monocrystalline PV Module 3 9 0 W • 3 9 5 W • 40OW - 40.5 W ELECTRICAL CHARACTERISTICS STCflrmd ceL000wim aduh,ee a gmrerscAM=,.n. Il . S165 546G1/BHI-390V SL65-546GJ/BH1-395V SL65-,546GJ/BHJ=400V SL65 54BGJ/BH1-405V I Imo_ Rated Power(Pmax) 39OW 395W 40OW 405W Voltage at Pmax(Vmp)` 30.82V' 31 AOV 31.17V 31.36V- Current at Pmax(Imp) 12 56A 12 75A _-12 84A j 12 92A — -- — Warranted Minimum Pmax 390W 395W 400W -_ 405W Short Circuit Current(Isc) 13 50A I 13.59A 13 68A 13 78A _ ) _. Open Circuit Voltage(Voc) 36 84V F 37 03V 37 20V 37 36V Module Efficiency 19.97% 20.23% 20.48% 20.74% O'eeatin ModuleTem erature 40�to+85n P g P Maximum System Voltage 1,500V Fuse Ratmg, 30A Maximum Reverse Current r 4 5A Power Tolerance 6 o+5W ELECTRICAL CHARACTERISTICS backside powergain(reference to 40OW front) *BifacialityZgo% Pmax `. 426W xr 446W - 45OW' -46oW 500W Voltage at Pmax(Vmp) 31 2oV 31 20V _ 31 20V 31 30V 31 30V — I __. _ —_ 1_ .. Current atPrrlax(Imp) f ;1347A 14)2A 1476A 15.35A 1599A Short Circuit Current(Isc) _ 14 36A 15.05A - 15 73A-- i 16.42A 17.1 OA I Open Circuit Voltage(Vc c) -37 20V - 37 20V ' - 37 20V 37 30V - 37 Pmax gain 5% I 10% 15° zo% zs% MECHANICAL CHARACTERISTICS 1134 I44.s5) Solar&l15 : Monocrystalline Bifadal Cells 182x91 mm (" I Numberof Cells 54 Haff Cells(6x18 Matroc)' ©©®© I D a dons: 1,722 x 1,134 x 30mm !Front/Rear Load 5 400Pa/2 400Pa Quoting hole I We ht 21.4 ig t kg l ©©©© l.Gkiss 3 2mm High Transmittance Low Iron Tempered Glass ©©©© Back Sheet Transparent Back sheet(White/Black) uo Hine zra A Frame Anodized Aluminum Frame(Silver/Black) ©©©® 21P67 with 3 bypass diodes ®©©© I OutpytCables PVWire(PV7 H 12AWG(4mrr�)CableLengih:SOQmm ®©©® E _ *cable length can be custom¢ed ©®©© e= Connectors` 'j MC4Original,Compatible EM®©©© TEMPERATURE CHARACTERISTICS ©©©© 16EA°ge hole 4empera0nec6efficient'of1sc 0.048% 1093 [43.03] TemperaturecoeffiderrtofVoc� 0 270%/'b Unil:mm i [inch] Temperature coeffiuentof power 0 320°//b MI NOCT(l'air20C;t7diancea6dW162,Wind lm/s) - :45±2 C ammma.x PACKING CONFIGURATION S e Container 20' 40' a s Modules PerPal1k. 36pcs _P 35pcs —gym _ Pallets PerConbiner_ 6pallets 24pallets =gym-"::;u� Modules Per Container. 216pcs 864pcs wM� d M Pmax measurement tolerance ±2.5%, Installation instruction supplied with the module must be S Energy uses triple A class simulator. duly followed.For further information which is not ; REMARKS Specifigy use subjee A c ass simchange wi tor. prior notice. NOTES mentioned on installation guides or directions;please S-Energy reserves the rights of final interpretation. contact:lnqur y@s-etechnical service department. •E-mail:Inquiry@s-energy.com ENPHASE, OE Elm IQ8 and IQ8+ Microinverters Our newest I108 Microinverters are the industry's first micro grid-forming,software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors . 55nm technology with high speed digital logic and has super-fast response times power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC).between components energy systems. . Faster installation with simple - i two-wire cabling hase ew High.productivity and reliability . • Produce power even when the year limited grid is down warranty • More than one million cumulative - Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability hours Of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest SAFETY advanced grid support' Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide - range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements I Q8S P-DS-0002-01-E N-US-2021-10-19 IQ8 and IQ8+ Microinverters INPUT DATA 1OC1 108-60-2-US1' Commonly used modulepairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell j I j MPPT voltage range v j 27-37 29-45 j Operating range V 1 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 I Max DC current'[module Iscj A 15 Overvoltage class DC port i II DC.port backfeed current mA i 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit j OUTPUT D J 1' .1 A" Peak output power VA I 245 300 I i Max continuous output power VA 240 290 I I Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit° + 16 I 13 I Total harmonic distortion <5% Overvoltage class AC port i III AC port backfeed current MA 30 i Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85leading-0.85lagging Peak efficiency 1 97.5 97.6 CEC weighted efficiency / 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -400C to+60°C(-40°F to+140°F) I, Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 I Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating I NEMA Type 6/outdoor 1 CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014;NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBSP-DS-0002-01-EN-US-2021-10-19 SERIES 100 FLASH- ED L FOOT SnapNrack Residential PV Mountin.g Systems The SnapNrack line of solar mounting 9 } $ t "} rUs of v o- h w Yoh �f -T 51�.7- "f,�✓' s-5 .c-r %' Ste. systems is designed to reduce total �,� �.����� - � � .. �. �.�-�`�� installation costs. The system features - �aW-�� technical innovations proven on more �1 < than 20OMW of solar projects to simplify installation and reduce costs. b Flashed L Foot Simplified - q` SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over 4 Y the life of the system. The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L.Foot in '3 Simple'Steps' shingle roof with no required cutting of shingles. The L 1) Locate the rafter and drill the pilot-hole - Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and -attach--the L root • 1" slotted bolt connection • 1" spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which,can be found at • No Cutting of shingles www•snapnrack.com/contact SnapNrack- Patent Pending pd MOo unang apoUma - i I I I .1 zn Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1'spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACK CHANNEL NIIr /-SNA.PNRACK 92 DEGREE L-FOQr,CLEAR i 5116-16 FLANGE NUT / 5/16.18X SIN BOLT WITH SPLIT LOCK WASHER �SNAPNRACK COMPOSMON FLASHING 4' � 3.43 `SNAPNRACK L-FOOT BASE .B8 SnapNrack Flashed Foot TechnicalData Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapN rack- FV Mounting syztem!s (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. re) ?ni-4 h%,Cn—KI—L,P\/Mnitntinn C,—tom All rinhtc rac --i SERIES 100 UL ROOF MOUNT S.napNrack Solar Mounti�ng Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) kil:11 xr � ? - module installation system. Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for ROOF System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware. The System's components provide Tool (configure.snapnrack.com) and.select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 2) Identify Site-Conditions(Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type,°Wind and Snow Loads) j the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically,generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules V` LISTED PV Mounting System Patent Pending 2703 421ainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Railpl -Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNrack Bonding �. � _ SnapNrack " Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding a RBoncln� iSnapNrack Adjustable End Bonding Stainless Channel Nut Clamp Bottom Ch nn I N Stainless Hardware with Bolt with a e ut Split Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding washer Adjustable End Clamp p g SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap � M r ��®���� ��,o UEC Wedge Stainless Steel Bolt � with Flat Washer SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly A SnapNrack Serrated Stainless�� SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut > Steel Flange Bolt Stainless SnapNrack a.- SnapNrack Mill Finish 92 Degree Flange L Foot Bolt Standoff v SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack ®: SnapNrack Metal Roof Base Shown) ; ' Mill Finish L Foot Base Assembly L Foot Base Flashing SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack Series • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish • Clear and black anodized aluminum • Mill Finish on select components Installation • Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com Printed on recycled paper using soy based inks.