Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51199-Z
�o�a�F soulyo�o Town of Southold * * P.O. Box 1179 w �0 53095 Main Rd �y�nu►ir��,�' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45751 Date: 11/09/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property. 1275 Bight Rd Orient,NY 11957 Sec/Block/Lot: 14.-2-11.13 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 08/07/2024 Pursuant to which Building Permit No. 51.199 and dated: 09/17/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to: 1275 Bight Road LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51.199 11/04/2024 PLUMBERS CERTIFICATION: A ho zed Signature �o�,�oFSQ�ryo(° TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51199 .Date: 09/17/2024 Permission is hereby granted to: 1275 Bight Road LLC 6840 SE Harbor Cir Stuart,FL 34996 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. Premises Located at: 1275 Bight Rd, Orient, NY 11957 SCTM# 14.-2-11.13 Pursuant to application dated 08/07/2024 and approved by the Building Inspector. To expire on 03/19/2026. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total S325.00 Building Inspector oF so�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 �� • �o Jamesh D-southoldtownny.gov BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION. Issued To: 1275 Bight Road LLC. Address: 1275 Bight Road city:Orient st: New York zip: 11957 Building Permit#: 51199 Section: 14 Block: 2 Lot: 11.013 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Element Energy LLC. Electrician: Jaime Minnick License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 70a Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 17kw roof mounted solar energy system with 40 panels Dinko solar jkm425n-54hi4-b] 40 microinverters[ enphase ig8mc-72-m-us, 1 fused disconnect,1 enphase combiner panel Notes: SOLAR ENERGY SYSTEM Inspector Signature: J99k Date: November 4, 2024 1275 bight rd ��a SO 5� TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/-REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND . [ .] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 5014,P [ ] FIREPLACE & CHIMNEY. [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ :} FIRE RESISTANT.PENETRATION' [ ' ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ,]. RENTAL REMARKS: OIL ` OtZ -C • 0' lli l DATE INSPECTOR ho�a0FS0UTyolo Alt `QQ ta7 s � TOWJZF SOUTHOL BUILLING DEPT.' "Cou�nN 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR . [ ] ROUGH PLBG. [ ] .FOUNDATION 2ND. [' `.:]' INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ]. FIRE SAFETY INSPECTION [ ] _ FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT.PENETRATION ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [, ] PRE.C/O [ ] RENTAL REMARKS: 6o a r BoK& Sere-u.)ul- &'5LOAl DATE 10 INSPECTOR 10/23,^_l 4:". RAND2.Jpe" 1 • �t J b'1V c .Y K ea a https://dri ve.goo-le.com/drive/u/0/folders/[a9ZHXd7bCpokYb[3s-tu2nB2rBDE7om_ I/I 10/23/24,4:58 PM RAND SCREW I jpg i w t>> hitps://drive.google.com/dri ve/u/0/folders/I a9ZHXd7bCpokYbl3s-tu2nB2rBDE7om_ 1/I - s % "J 1 -4 t)t tqq Page 1 of 1 Southold town ��� 9� rt'011116 � Current Renewables 10i21i2024 Engineering Subject: Structural Observation Report Job: Rand Residence Project Address: 1275 Bight Road, Orient, NY, 11957 Attn.: To Whom It May Concern After inspecting the installation of the above referenced project, it is the opinion of Current Renewables Engineering to certify that to the best of our knowledge, belief, and professional judgment the PV installation is in conformance with the Structural Calculations. Verification of all relevant installation methods and materials was provided by Element Energy LLC. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. Exp:09/30/2025 c tof NEW y Current Renewables Engineering Inc. Professional Engineer info currentrenewableseng.com 106793 Signed on:10/21/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com 'IELD INSPECTION REPORT DATE COMMENTS rr � r FOUNDATION (1ST) — - --- - C FOUNDATION (2ND) z -- o J, k3l� ROUGH FRAMING& PLUMBING S 4J 1 W d . � r INSULATION PER N.Y. STATE ENERGY CODE — •a�•� O/L �- C•D. s/�.Gk.din� e � FINAL ADDITIONAL COMMENTS q.Zo •2� a.� — �p t-Co f-�L �c-c fk l O 2� 0 k - � 3 0 z � x d b H TO,VN OF SO!UTHO]LD—B!I:TILDlfIYG DEPARTMENT x. Town Hall Annex 54375 Main road P. 0. Box 1179 Southold NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 hgns:. �wc��osostEhol�lto�4nn, Doti i l I Date Received APPLICATION FOR BUILDING PERMIT i For Office Use Only PERMIT NO. Building Inspector: AUG � ,D��a�rroes�t Applications and forms crust be filled o at in their entirety.Incomplete 1la�lr�g ,outsnold applications hill not be accepted. IVVhere the G'wylnees Authvirliation foor a, IP`-ge 2)shaft be completed, OWN i ERM OF PROPERTY; Name. 11 1 I1"t"i ^Gl SCTM# 1000- Li. o(D ()z -otll—o (,l , 013 Project Address: �a 5 �' AJ C4 1 1 9 s Phone#: s 2 d 7,c)14 Email: Ill ru D - Mailing Address: I CONTACT PE O . iName: Lo 1r-rA,,.n.c t Pe. Mailing Address: —7 4?o 'v �d a I Phone#: (V Email al Name: I Mailing Address: Phone#: Email: CONTRACTOR INFO WATION.-, Name: 1 �.D'l� y)t�q L4 Mailing Address: � 4 Phone#: 0 2 0 - 13 4 ) Email: DESCRiPlION OF PROPOtED CON57R1ff ON ❑Nevv Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ther I n54-A-d �z.y- P V $ 41 .T rZ q 0, Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? ❑Yes�N° o I I 1 I: PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ONO IF YES,PROVIDE A COPY. D Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPUCATION 5 HEREBY MADE to the Building Department for the issuance of a Building Perms pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applk able laws,ordinances,building code, housing code and regulations and to admit authorised inspectors on premises and in buildingis)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section Z10AS of the New York State Penal Law. Application Submitted B not name •Lorraine DiPenta Pp Y(P • name):Lorraine Agent ❑Owner Signature of Applicant: Date: &A STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine Di Penta being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this e— ;;Z�� 9-v—� day of -� c� I 20 2 t_r Not Public PROPERTY OWNER AUTHORIZATION LOUIS J ROMEO Notary Public,State of New York (Where the applicant is not the owner) No.01 R06314813 Qualified in Suffolk County n Q ^ p Commission Expires November 17,20�6 ,te I, ' r `1 t lt� � / \(� /W� residing at }�� �j i'U �l-r� 1d do hereby authorize CI-tLl'YLenL sHf✓ -t> i" nia.-to apply on my behalf to the Town of Southold Building artment for approval as described herein. Owner's Signature 6ate G k Ck e �� ,Q LOUIS J ROMEO " �` �rlotary Public,State of New York Print Owner's Name No.01R06314813 Qualified in Suffolk County Commission Expires November 17,20rL' 2 g�GF BRIO D(ING DEPARTMENT- fEle c�r c TOWN OF SOUTH Town Hall Annex - 54375 Main Ro POO& 1179 v' x • Southold, New York 1197 59 Telephone (631) 765-1802 - FAX (631) 7 V 50a\j0od r®gerr(ci)southoldtownny.gov seand(c_southoldit'Wnny_pov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Au Information Required) Date: � 2 Company Name: EleMCA4 E n f,rr (-L.(j Electrician's Narne:UiA. License No.: In26 3�,4 Elec. email: Per'r i (a, Cad yS, e_o4 Elec. Phone No: ;-p�r,3 [ZI request an email copy of Certificate of Compliance Elec. Address.: -3 4-7 o ,S9 vrj). otv& ii b ie_, JOB SITE INFORMATION (All Information Required) Name: ry1rcha-e-1 R ot Address: I a- �' h PK k () � - 1 -7 Cross Street: PAC_+ - Phone No.: (0,5 A � °�. 0 Lt Bldg.Permit#: email: 1PZ M 4 Tax Map District: 1000 Section: 0 1 y •00 Block: ®;Z , co Lot: o I ooL3 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES �NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES®NO Issued On TernP Information: (All information required) Service Size®1 Ph®3 Ph Size: A #Meters Old deter# New Service[:]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? 0 Y FIN Additional Information: PAYMENT DUE WITH APPLICATION A���® CERTIFICATE OF LIABILITY INSURANCE DATE(MM7/16/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT ROBERTS. FEDE INSURANCE AGENCY NAME: PHONE - FAX 23 GREEN STREET,SUITE 102 Alc No Ext: AIC No): E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS. FEDE INSURANCE INSURERS AFFORDING COVERAGE NAIC# INSURERA:ADMIRAL INSURANCE COMPANY 24856 INSURED INSURERB:STATE INSURANCE FUND 523930 Element Energy LLC INSURERC:SHELTER POINT POINT _BT43�17- DBA ELEMENT ENERGY SYSTEMS INSURER D:GENERALSTAR AGEMENT CO. 37362 7470 SOUND AVENUE INSURER E MATTITUCK, NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR I ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DD/YYYY) (MMIODNYYYI LIMITS COMMERCIAL GENERAL LIABILITY CA00005380701 EACH OCCURRENCE $ 1,000,000 A X X 7/14/2024 7/14/2025 DAMAGET RENTED CLAIMS-MADE TI OCCUR PREMISES Eacccurrence $ 300,000 IMA389203C MED EXP(Any one person) $ 5000 X 7/19/2024 7/19/2025 &ADV INJURY $-PERSONAL1000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY E]jE O LOC PRODUCTS-COMP/OP AGG $ 1/2 0000 00 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANYAUTO BODILY INJURY(Per person). $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Peraccdent $ UMBRELLA UAB OCCUR EACH OCCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION 124494445 AND EMPLOYERS'LIABILITY Y/N STATUTE ERH ANY PROPRIETOR/PARTNER/EXECUTIVE 7/13/2024 7/13/2025 B OFFICERIMEMBER EXCLUDED? N/A E.L.EACH ACCIDENT $ I 1 OOO OOO Mandatoryin E.L.DISEASE-EA EMPLOYE $ f yes,describe u under nd 1,000-000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL DBL567527 1/01/2024 12/31/201 Statutory DESCRIPTION OF OPERATIONS!LOCATIONS!VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached It more space Is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED- CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold, NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE R(J - S. Fede, C 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Yo T Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1 c.Federal Employer Identification Number of Insured Work Location Of Insured(Only requi2d if coverage is specifically limited to Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN STREET 3b. Policy Number of Entity Listed in Box"1a" SOUTHOLD, NY 11971 DBL567527 3c.Policy effective period 01/01/2024 to 12/31/2025 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. S. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I.am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2024 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title LeStOn WeISh,Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 46,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 413,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) III III 111iiiuiiiiiUiiiiiiiiiiii�iiiiiiiiiiimiii1111, 1 N Y S ' F New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) A^AAA^ 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 [Gil SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 962287 07/13/2024 TO 07/13/2025 7/11/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF .THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF .INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SURANCEFUND D I RECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 743799006 V OCCUPANCY OR APPROVED AS NOTED USE IS UNLAWFUL DATE. •/'�a B.R#t 57/ WITHOUT CERTIFICATE FEE` 3oZ S BY: OF OCCUPANCY NOTIFY BUILDING DEPARTMENTAT 631-765-1802 8AM TO 4PM FOR THE r)i I nlAtING INSPECTIONS: ATION-TWO REQUIRED {RED CONCRETE FRAMING&PLUMBING _N�ION FINAL-CONSTRUCTION MUST �EV YORK STATE$TOWN WITH ALL CODES OF �. BE COMPLETE FOR C.O. AS REQUIRED AND CONDITIONS OF 1LL CONSTRUCTION SHALL MEET THE 'EQUIREMENTS OFTHE CODESOF NEW XMIflTomm ORK STATE. NOT RESPONSIBLE FOR :%wwwammom SIGN OR CONSTRUCTON ERRORS SOUtiICI,QIOWN IDIiA�. mum sm e RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Page 1 of 2 08/06/2024 Current Renewables Element Energy LLC Engineering 7470,Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Rand Residence Project Address: 1275 Bight Road, Orient, NY, 11957 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 .��OF NE41 y A. Z4 O'p•F Current Renewables Engineering Inc. Professional Engineer W info@currentrenewableseng.com ti 106793 ��� F W Signed on:08/06/2024 1760 Chicago Ave Ste J13, Riverside, CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 i Summaries: i Check 1 : Shingle roofing supported by 2x6 Rafter @ 16 in..OC spacing. The roof is sloped at approximately 34 degrees and has a Max beam span of 8.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are req"ired. . Check 2: Shingle roofing supported by 2x6 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 17 degrees and has a max beam span of 10.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2X10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 15 degrees and has a max beam span of 22.8 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. . i I I i i I - i I I i 1760 Chicago Ave Ste J13, Riverside, CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1 : Shingle roofing supported by 2x6 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 34 degrees and has a max beam span of 8.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x6 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 17 degrees and has a max beam span of 10.0 ft between supports. Roof is adequate to support the imposed .loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 15 degrees and has a max beam span of 22.8 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside, CA 92507 (951)405-1733 info@currentrenewableseng.com Exp.09/30/2025 ROOF MOUNT SOLAR PERMIT PACKAGE ��pFNEWI, A. M I C H A E L RAND * e �goO,P 17.000 KW DC GRID TIED PHOTOVOLTAIC SYSTEM I 106793 1275 BIGHT RD, ORIENT, NY 11957 Signed on:08/06/2024 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES: THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY REPRODUCTION IN ANY FORM IS � WRITTEN POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION APPROVAL EXPRESSLY FORBIDDEN MCURENT WITHOUT PRIOR� 2020 BUILDING CODE OF NEW YORK STATE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES RENE ABLES E INC ENGINEERING 2020 RESIDENTIAL CODE OF NEW YORK STATE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED 2020 EXISTING BUILDING CODE OF NEW YORK STATE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 2020 FIRE CODE OF NEW YORK STATE UNDERSIGNED Current 2020 PLUMBING CODE OF NEW YORK STATE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 Rene W auje�. pert)/$ Dr 2020 MECHANICAL CODE OF NEW YORK STATE 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT 2017 NEW YORK STATE ELECTRICAL CODE SUCH AS GeoCel 2300 CLEAR SEALANT Engineering Iq 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED- CURRENT RENEWABLES ENGINEERING INC. ay 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, 1760 CHICAGO AVE SUITE J-13 RIVERSIDE CA 92507 MECHANICAL,OR BUILDING ROOF VENTS PHONE(951)-405-1733 WWWCRENGCO AHJ TOWN OF SOUTHOLD 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE CONTRACTOR INFO LEGEND 10 EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA ®El uM UTILITY METER PM PRODUCTION METER REGULATIONS Cz5\/S 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" ii SP MAIN SERVICE PANEL INv INVERTER 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY ELEMENT ENERGY LLC. AUTOMATIC BUILDING INFORMATION TS TRANSFER SWITCH UB SUB PANEL 15. MODULES GROUNDED INVERTER,IN THE CONFORM TOAND ARE L STED UNDER UL 170 NTH 690.35 7a7o sDNE UND AVENUE. TTnUCK, W YORK.11 52 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PH:es e2s s.co 7993 COMBINER secence- E-52689 LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE Licence-ME-52689 2 STORY HOUSE SINGLE FAMILY RESIDENCE NEC,THE INSTALLATION STAN DARDS/MANUFACTURER'S RECOMMENDATIONS AND IF (MASTER ELECTRICIAN) AC DISCONNECT REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. Licence- IMPROVEMENT) IQ CONTROLLER 2 I('� (SUFFOLK HOME IMPROVV EMENT) 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8'. CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U MODULE ABOVE ROOF SURFACE. ❑ ElBATTERY 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE MICHAEL RAND AP N 1000014000200011013 ROOF OBSTRUCTIONS RATED FOR EXPOSURE,TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN 1275 BIGHT RD, No36"ACCESS PATHWAYS OH O.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT ORIENT,NY 11957 SHEETINDEX M 18"ACCESS PATHWAYS AC ESS DISCONNECT 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDAR S,RULES A D REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO AHJ TOWN OF SOUTHOLD LC LOAD CENTER THE PURPOSE INTENDED: LONG ISLAND POWER AUTHORITY PV-1.0 COVER PAGE ROOF ACCESS POINT UTILITY (LIPA) PV-2.0 SITE PLAN _ MBE MAIN BREAKER O SEPTIC TANK WIND SPEED 128 PV SUMMARY ENCLOSURE SNOW LOAD 25 SYSTEM SZE STC 4zs x ao = z000 SSS (KWDC) PV-2.1 ROOF PLAN _ AUTOMATIC TRANSFER LEACH LINES PTc 3sB i x ao= ssza PV-3.0 STRUCTURAL Ts EXPOSURE CATEGORY C SWITCH PROPANE TANK SYSTEM SIZE PV-4.0 ELECTRICAL 3LD OP PERMANENT ANCHOR (::D WELL MODULES 40 JINKOSO 1KM425N-54-54HL4-B MICROINVERTER 40 EN PHASE PV-4.1 ELECTRICAL SLD TC TEMPORARY ANCHOR O POWER LINES QBMC-72-M-US PV-4.2 ELECTRICAL PHOTOS 17 NO LADDER ACCESS IL INSTALLER LADDER (STEEP GRADE PV-5.0 BOM _ OR GROUND LEVEL PV-6.0 SIGNAGE & PLACARD S❑ STUB-OUT OBSTRUCTIONS) PV-7.0 SPECS+ ® SKYLIGHT As GAS SHUT OFF R0 INITIAL V Description DESIGN 81/2024 ❑ H2O WATER SHUT OFF A RESTRICTED ACCESS e 0 SERVICE DROP PROJECT# NA CONDUIT DATE DRAWN 8/6/2024 RAIL DRAWN BY ER RAFTER SHEET# PV-1 o ATTACHMENT TITLE JUNCTION BOX COVER PAGE R32 NOT L.1 PATHWAYS: LEGEND Exp 09/30/2025 NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SEPARATE ROOF PLANES, ENLARGED VIEW EOF NE►y FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON p� �, ALL BUILDINGS. A. •P AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM \ SP MAIN SERVICE PANEL cr 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE \ r_ SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING \ AUTOMATIC n �v THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE ( F-c C UM I TS TRANSFER SWITCH V= OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS �`A 106793 (� ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS \ C❑ COMBINER A P� WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR \ TS MSP F N MECHANICAL EQUIPMENT. \ /� AC DISCONNECT - ROOF ACCESS POINT R324.6.2 SETBACK AT RIDGE: i Signed on.08/06/2024 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 MODULE PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN ROOF OBSTRUCTION AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A \ ROOF OBSTRUCTIONS THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. \ COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PATIO \ 36"ACCESS PATHWAYS REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A POOL \ 18"ACCESS PATHWAYS ERITTEN APPROVAL ENGINEERING FROM CURRENT HORIZONTAL RIDGE. \ 309'-10" INC R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS r \ ROOF ACCESS POINT AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED PROPERTY LINE \ Current THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE / Renewabies AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE I \ %• Engineering PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. \ 52'-10" \ • CURRENT RENEWABLES ENGINEERING INC. NOTES: 1 \ / 1760 CHICAGO AVE SUITE J-13 RIVERSIDE CA 92507 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED '� \ �• PHONE:(951)105-1733,V1NWV.CRENG.CO ON ACTUAL SITE CONDITION AND I \ MEASUREMENTS. i LF CONTRACTORINFO 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS SHED DRIVEWAY = INCORPORATED INTO THE 2017 NEC AND UL 1„ t: O• STANDARD 1741. 93 55' 11" dum 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. 1 ,• (� E2SYS9 NOTES: ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MAT(TUCK, 1. METER LOCATION CAN NOT BE DETERMINED. "�;s: Q NEW YORK,11952 / PH:(631)779 7993 serices@e2sys.com NOTE: I — i Licence-ME-52689 NO FENCES OR GATES SURROUND THE PROPERTY (MASTER ELECTRICIAN) I _,••.. 82'-11 = Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) If coMICHAEL RAND I •°:'' 1275 BIGHT RD, ORIENT,NY 11957 DRIVEWAY f AHJ TOWN OF SOUTHOLD !; • LONG ISLAND POWER AUTHORITY I�� :; - �►.. A. . i UTILITY (LIPA) 1 ' + PV SUMMARY r f `may 1 M n SYSTEM SIZE I r a • 59 8 src azs x ao = 000 CD (Kwoc ) IA PTC 398.1 X 40 =15.924 SYSTEM SIZE (KWAC) 12.80 @240 ` 1 MODULES 40 11NKO SOLAR 1KM425N-54HL4-B MICROINVERTER 40 1 ENPHASE 296-10" 8MC-72-M-US ROOF LINE ROOF ACCESS POINT Rev Descnplion Date STRUCTURAL NOTES A. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE 0 INITIAL DESIGN 8/6/2024 ROOF FRAMING SUPPORTING THE PROPOSED PV INSTALLATION ONLY.2. THESE PLANS ARE NOT A STAMPED FOR WATER LEAKAGE.3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS MUST B FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS.4. PLEASE SEE THE ACCOMPANYING PROJECT# NA STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION.5. PRIOR TO COMMENCEMENT DATE DRAWN e/6/2024 SITE PLAN OF WORK, THE SOLAR INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND DRAWN BY ER 1 NOTIFY THE E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING:ROOF 1: SHEET# Pv-20 eb 2x6 RAFTERS @ 16" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. ROOF 2: TITLE SCALE: 3/128" _ -O�� 2x6 RAFTERS @ 16" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 10 FT.ROOF 3: SITE PLAN 2x10 RAFTERS @ 16" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 22.8 FT. ARRAY AREA ROOF#4 LEGEND Exp. 025�pF N/2 ROOF TOTAL ROOF ROOF AZIMUTH #OF (AREA) AREOA AREA AREA I / uM UTILITY METER h�Po��I A. z�o0, TILT MODULES (Sq.Ft.) (Sq.Ft.) COVERED BY COVERED BY / c c uM ARRAY(%) ARRAY(%) sP MAIN SERVICE PANEL #1 34' 160' 12 252.24 5181 4.87 _ _ _ _ _ _ AUTOMATIC r L 17' 250' 3 63.06 5181 1.22 16.23 .' — TRANSFER SWITCH 15, 250' 15 315.30 5181 6.09 �' — — — I cCOMBINER .!'15' 250° 10 210.20 5181 4.06 _ _ �0 106793 � _I ,o F NPR I AC DISCONNECT MODULE Signed on:08/06/2024 ROOF OBSTRUCTIONS THESE DRAWINGS ARE SUBJECT TO 36"ACCESS PATHWAYS COPYRIGHT PROTECTION BY US LAW. / REPRODUCTION IN ANY FORM IS ® 18°ACCESS PATHWAYS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT / -- RAIL RENEWABLES ENGINEERING INC. ( Fc C UM : ) --- RAFTER Current t� TS MSP �/ _ _ _ - - ATTACHMENT Renewatles Engineering / I I CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 4PHONE:(951}4051733.WWW.CRENG.CO ENLARGED VIEW CONTRACTOR INFO I t. ®El � i I EZSYS9 —1 oill _ _ I ELEMENT ENERGY LLC. (� I 7470 SOUND AVENUE,MA77ITUCK, NEW YORK,11952 Q PH:(631)779 7993 services@e2sys.com ROO 3 I Licence-ME-52689 I (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) MICHAEL RAND _ t m 1275 BIGHT RD, ORIENT,NY 11957 ROOF# - AHJ TOWN OF SOUTHOLD UTILITY LONG ISLAND POWER AUTHORITY (N)40 JINKO SOLAR JKM425N-54HL4-B i (LIPA) PV SUMMARY SYSTEM SIZE STC 425 X 40=17.000 3 / I (KWDC) SYSTEPTC 398.1 X 40=15.924 KWACM SIZE 1280 @240 .41 MODULES 40 JINKO SOLAR yy JKM425N-54HL4-8 MICROINVERTER 40 ENPHASE IQ8MC-72-M-US i Rev Description Date 0 INITIAL DESIGN 81612024 A UA 3' B PROJECT# NA J DATE DRAWN 8/6/2024 DRAWN BY E.R ROOF PLAN ROOF#1 _ SHEET# PV-21 TITLE SCALE: 3/32` = 1'-T' �� i_ __ __+ _ ROOF PLAN TABLE 1 TABLE 2 Exp.09/30/2025 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX OF NEW,,, NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG ��Q 0��t A. lq 0 s2 ATTACHMENT IRONRIDGE QUICKMOUNT HALO ULTRA O o GRIP ROOF 1 34 COMP SHINGLE RAFTER 2 X6 16" 64" 24" s3 RAIL IRONRIDGE XR-100 RAIL ROOF 2 170 COMP SHINGLE RAFTER 2"X6" 16" 64" 24" ROOF 3 150 COMP SHINGLE RAFTER 2"X10" 16" 64" 24" �J�� 106793 ROOF 4 15' COMP SHINGLE RAFTER 2"X10" 16" 64" 24" A F r1P Signed on:08/06/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 0:;*,: Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE(951)-405-1733.VWVW.CRENG CO MODULE CONTRACTORINFO S3 TABLE : PENETRATION ®El S2 TWO OR MORE ROWS OF PANELS GUIDE FOR INSTALL EZSYS RGY ROOF 7470 SOUNDNAVENEUE,MALTnTUCK, NEW YORK.11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 I I I I I I I I I I I I I I I I I I (MASTER ELECTRICIAN) Licence-HI-67461 2.5"MINEMBED. III III 1II III III III III III III III III III III III III III III III III II (SUFFOLK HOME IMPROVEME NT ) M CM MICHAEL RAND SELF DRILLING 1275 BIGHT RD, (2)-#14 X 3 ORIENT, NY 11957 TUAL SCREWS TO AHJ TOWN OFSOUTHOLD S1 ::: EXISTING STRUCTURE STACKED STAGGERED FULLY STAGGERED UTILITY LONG ISLAND POWER AUTHORITY (LIPA) ENLARGED VIEW ONE ROW OF PANELS SYSTEM SIZE PV SUMMARY (KWDC) STC 425 1.14.1= 17.000 PTC 398.1 X 40=15.924 SYSTEM SIZE 12,80 @240 E. (KWAC) I I I I I I I I MODULES 40 11NK0 SOLAR 1 KM425N-54H L4-B I I I I I I I I MICROINVERTER 40 ENPHASE MODULE ! IQBM`-72-M-US FULLY STAGGERED STACKED/STAGGERED —� r SEE ENLARGED VIEW Rev Description Date 0 INITIAL DESIGN 8/612024 A B PROJECT# NA ROOF DATE DRAWN 8/62024 DRAWN BY ER ISHEET# PV-3.0 ATTACHMENT DETAILS TITLE STRUCTURAL BACKFEED FUSE SIZING ACCOUNT NUMBER:9683042153 OF NEt1, MAX. CONTINUOUS OUTPUT 1.33A @ 240V METER NUMBER: 098276332 �Q���E MAN7q yO,Q 53.20 X 1.25 = 66.50AMPS 70A FUSES-OK (E)UTILITY * 4/ G 14/ METER t— ' D W 3 c� 1 2 099128 W 2 A (N)ENPHASE 2 COMBINER BOX (E)200A AUTOMATIC ® ��O CTRICP� TRANSFER SWITCH AROFESSIONP� 1 BRANCH OF 10 CELL WIRE LESS PV MODULE IN MODEM COMMS STAMPED 08/06/2024 IQ GATEWAY (E)200A/2P MAIN BREAKER THESE NGS ARE SUBJECT TO 2 BRANCH OF 10 N)15. COPYRIGHT PIROTECTION BY US LAW. PV MODULE — (N)2oAm REPRODUCTION IN ANY FORM IS —� /\ EXPRESSLY FORBIDDEN WITHOUT PRIOR (N)20A/'f\ (N)LINESIDE TAP VIA UL WRITTEN APPROVAL FROM CURRENT TO(E) LISTED CONNECTORS RENEWABLES ENGINEERING INC. (N)2OA/1\ i 4//''�� GENERATOR (N)FUSED Current 3 BRANCH OF 10 (N)20A AC DISCONNECT • ~ PV MODULE N, r-- — (N)70AFUSES Renewables _J GENERATOR TO UTILITY _— _-------- Engineering I L---- � L---------- --- al.fb ---- ------ ------------- BREAKER GRID 6 —— CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 4 BRANCH OF 10 I PHONE(951}405-1733 VWWW CRENG CO N —J 6AWG COATED GEC,COPPER PV MODULE , -——— GROUNDING CONDUCTOR I —— CONTRACTOR INFO _J B C I — I (E)200A RATED — MAIN SERVICE PANEL 1 PH,120/24DV 60HZ (E)200A/ NOTE: I 2P MAIN EXISTING WIRE CZSYS 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS I BREAKER AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. I (TOP FED) I ELEMENT ENERGY LLC. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH I I 7470 SOUND AVENUE,MATTITUCK, PROPER JUNCTION BOX AT EACH END PER 690.31A I I NEW YORK,11952 • I PH:(631)779 7993 • I services@e2sys.com 689 MODULE ELECTRICAL EQUIPMENT LIST i i LicenceELECTR CIA JINKO SOLAR (MASTER ELECTRICIAN) • Licence-HI-67461 MANUFACTURER I i (SUFFOLK HOME IMPROVEMENT) S. NO. ITEMS DESCRIPTION QTY. I I MODULE MODEL JKM425N-54HL4-B 1 PV MODULE 40 JINKO SOLAR I I MICHAEL RAND I I JKM425N-54HL4-B I I 1275 BIGHT RD, MODULE(W) 425 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 40 j I ORIENT, NY 11957 MODULE PTC(W) 398.1 I MODULE Isc(A) 13.58 3 COMBINER ENPHASE IQ COMBINER 1 I AHJ TOWN OFSOUTHOLD 5/5C I MODULE Voc(V) 38.95 100A RATED D223NRB I UTILITY LONG ISLAND POWER AUTHORITY MODULE Imp(A) 13.13 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 L________________ (UPA)PV SUMMARY LOCKABLE NEMA 3R UL (E)GROUNDING ELECTRODE SYSTEM SIZE MODULE Vmp(V) 32.37 LISTED CONDUCTOR#6 BARE COPPER KWDC) STC 425 X 40 = 7000 PTC 398.1 X 40 = 5.924 SYSTEM SIZE 1280 @240 WIRE CALCULATION (KWAC) MODULES 40 1INKO SOLAR STARTING ADJUSTMENT MAXIMUM KM425N-54HL4-B STARTING TEMPERATURE ENPHASE CURRENT FACTOR FOR ADJUSTED CURRENT MICROINVERTER 40 IQ8MC-72-M-US CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION TAG QTY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (�C)DESCRIPTION FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS IN RACEWAY 310.15(B)(3)(a) IN RACEWAY 8 12 SKU: Q-12-RAW-300, THHN A N/A FREE AIR 30 90° 13.3 0.96 0.7 20.16 16.63 1 8 THWN-2 BARE COPPER-(GROUND) Rev Description Date 0 INITIAL DESIGN 8/6/2024 3 6 THWN-2 COPPER-(L1,L2,N) A B 3/4" PVC 75 90, 53.2 0.96 1 72.00 66.50 B 1 8 THWN-2 COPPER-(GROUND) PROJECT# NA 3 6 THWN-2 COPPER-(L1,L2,N) DATE DRAWN 8/6/2024 C 3/4" PVC 75 90° 53.2 0.96 1 72.00 66.50 DRAWN BY ER 1 8 THWN-2 COPPER-(GROUND) SHEET# PV-4.0 TITLE ELECTRICAL KID BACKFEED FUSE SIZING ACCOUNT NUMBER:9683042153 OF NEW MAX. CONTINUOUS OUTPUT 1.33A @ 240V METER NUMBER: 098276332 �QAl MgN�q-YO'P 53.20 JXT1 25 = 66-50AMPS 70A FUSES-OK (E)UTILITY Qui METER f ' D 3 W m _W 1 099128 2 2 A (N)ENPHASE E 200A AUTOMATIC 2� O COMBINER BOX ( ) ® F� CTRICP� TRANSFER SWITCH �O v 1 BRANCH OF 10 CELL WIRE LESS �40FE55�0�.1P PV MODULE N MODEM COMM STAMPED 08/06/2024 IQ GATEWAY (E)200A/2P MAIN BREAKER THESE DRAWINGS ARE SUBJECT TO 2 BRANCH OF 10 KN)15A:� COPYRIGHT PROTECTION BY US LAW. IN ANY M IS PV MODULE (N)2oA./I� EXPREESS ION YT FORBIDDEN WITHOUT PRIOR ,(N)20A./(� (N)LINESIDE TAP VIA UL WRITTEN APPROVAL FROM CURRENT // LISTED CONNECTORS RENEWABLES ENGINEERING INC. TO(E) (N)2D •/ 4 //'�� GENERATOR (N)FUSED • Current 3 BRANCH OF 10 I(N)20A AC DISCONNECT PV MODULE N (N)7oAFUSES • • Renewables BR 10KER GENERATOR TO UTILITY Engineering BREAKER GRID q� CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733.WVJW CRENG.CO 4 BRANCH OF 10 PV MODULE CONTRACTOR INFO B Lo (E)200A RATED MAIN SERVICE PANEL 1 PH,120/240V 60HZ (E)200A/ EXISTING WIRE NOTE: 2P MAIN CZSYS 1)CONDUITAND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS BREAKER AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. (TOP FED) ELEMENT ENERGY LLC. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH • • 7470 SOUND AVENUE,MATTITUCK, PROPER JUNCTION BOX AT EACH END PER 690.31A NEW YORK,11952 •�• PH:(631)779 7993 • services@e2sys.com 689 MODULE ELECTRICAL EQUIPMENT LIST LicenceELECTR CIA JINKO SOLAR •/ �• (MASTER ELECTRICIAN) • Licence-HI-67461 MANUFACTURER (SUFFOLK HOME IMPROVEMENT) S. NO. ITEMS DESCRIPTION QTY. • MODULE MODEL JKM425N-54HL4-B 1 PV MODULE 40 JINKO SOLAR MICHAEL RAND JKM425N-54HL4-B 1275 BIGHT RD, MODULE(W) 425 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 40 ORIENT, NY 11957 MODULE PTC(W) 398.1 MODULEIsc(A) 13.58 3 COMBINER ENPHASE IQ COMBINER 1 AHJ TOWN OFSOUTHOLD 5/5C MODULE VOC(V) 38.95 100A RATED D223NRB UTILITY LONG ISLAND POWER AUTHORITY (LIPA) MODULE Imp(A) 13.13 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 PV SUMMARY LOCKABLE NEMA 3R UL (E)GROUNDING ELECTRODE SYSTEM SIZE MODULE Vmp(V) 32.37 LISTED CONDUCTOR *6 BARE COPPER (KWDC) STC 425 X 40= 7.000 PTC 398.1 IXI401= 5924 SYSTEM SIZE 1280 @240 WIRE CALCULATION (KWAC) MODULES - 40 /INKO SOLAR STARTING ADJUSTMENT MAXIMUM JKM425N-54HL4-B STARTING TEMPERATURE MICROINVERTER 40 ENPHASE CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT IQSMC-72-M-US TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO QTY. SIZE(AWG) SIZE&TYPE AMPA RATING ('C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(1)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY SKU: Q-12-RAW-300, THHN A 8 12 N/A FREE AIR 30 90° 13.3 0.96 0.7 20.16 16.63 1 8 THWN-2 BARE COPPER-(GROUND) Rev INITIAL D DESIGN Date 0 INITIAL DESIGN 8/612024 3 6 THWN-2 COPPER-(L1,L2,N) A B 3/4" PVC 75 90° 53.2 0.96 1 72.00 66.50 B 1 8 THWN-2 COPPER-(GROUND) PROJECT* NA 3 6 THWN-2 COPPER-(L1,L2,N) DATE DRAWN 8/6/2024 C 3/4" PVC 75 90° 53.2 0.96 1 72.00 66.50 DRAWN BY ER 1 8 THWN-2 COPPER-(GROUND) SHEET* PV-41 TITLE I ELECTRICAL SLD EXISTING SERVICE PANEL PHOTOS ��OFNEV �P OQE MAN/"9 O�� CG r ' D m W_W oss,2a = CTR%rG- �C9 SSIONP STAMPED 08/06/2024 THESE DRAWINGS ARE SUBJECT TO •f ��� PROTECTIONCOPYRIGHT LAW � �i REPRODUCTION IN ANY FORM S if f •� a � EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RE NEWABLES ENGINEERING INC. Current fits Renewabies Engineering ray+ . # f i r1 s" t 4 GENERATOR i CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 J / r,f ,,:/T PHONE(951)-405-1733 WM CRENG CO Sv b `" CONTRACTOR INFO m .�� aE2SYS6®n ELEMENT ENERGY LLC. 7470 SOUND AVENUE.MATTITUCK, NEW YORK,11952 f� �� f PH:(631)779 7993 i s � / _ services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) yy Licence-HI-67461 f N = (SUFFOLK HOME IMPROVEMENT) MICHAEL RAND 1/ 1275 BIGHT RD, ORIENT, NY 11957 ' AHJ TOWN OF SOUTHOLD UTILITY LONG ISLAND POWER AUTHORITY (UPA) PV SUMMARY ,• SYSTEM SIZE STC 425 X 40 = 7.000 (KWDC) PTC 398.1 IX1401 115924 SYSTEM SIZE -(KWAC) 12 80 @240 MODULES 40 JIN KO SOLAR 1KM425N-54HL4-B MICROINVERTER 40 ENPHASE IQ8MC-72-M-US Rev Description Date 0 INITIAL DESIGN 816/2024 A B PROJECT# NA DATE DRAWN 8/6/2024 DRAWN BY ER SHEET# PV-4.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST pF NE�,y �P�O��`MgN/'�CO�'� ELECTRICAL EQUIPMENTS * D QTY. PART TYPE PART NUMBER DESCRIPTION m 099128 - 40 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B �oA << 40 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US RO ssioNP� 1 AC DISCONNECT D223NRB 100A RATED 240VAC NEMA 3R UL LISTED STAMPED08/06/2024 1 COMBINER X-IQ-AM1-240-5/5C Enphase IQ Combiner 5/5C THESE ARE SUBJECT TO 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS COPYRIGHT PIROTECTIONBYUSLAW REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE (951)-405-1733.WWW CRENG.CO CONTRACTORINFO ■Rii� BREAKER / FUSES E2SYS QTY. PART TYPE PART NUMBER DESCRIPTION ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATITFUCK, 1 FUSES 70A FUSES GENERAL 70A FUSES NEW YORK.11952 PH:(631)779 7993 4 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) Licence- Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) MICHAEL RAND 1275 BIGHT RD, ORIENT, NY 11957 RACKING AHU TOWN OF SOUTHOLD QTY. PART TYPE PART NUMBER DESCRIPTION UTILITY LONG AND POWER AUTHORITY 44 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK PV SUMMARY SYSTEM SIZE (KWDC) STC 425 X 40 = 17.000 16 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 PTC 3981 IXI401=115924 SYSTEM SIZE 12 80 @240 108 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK (KWAC) MODULES 40 JINKO SOLAR 56 CLAMPS & GROUNDING UFO-STP-30MM-B1 STOPPER SLEEVE, 30MM, BLACK ENPHASE 54HL4-B MICROINVERTER 40 IQ8MC-72-M-US 14 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 118 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK 236 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.01- 118 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE Rev Description Date 0 INITIAL DESIGN 8/6/2024 A B PROJECT# NA DATE DRAWN 8/6/2024 DRAWN BY ER SHEET# PV-5.0 TITLE BOM CAUTION ��OF NEl�,y �P ooE nnaa�,�v O�� MULTIPLE SOURCE OF POWER r— � • D W m w 099128 � PV ARRAY CTRIGP�. Ro SS1 PHOTOVOLTAIC SYSTEM, M STAMPED 08l06/2024 EQUIPPED WITH RAPID SHUTDOWN, THESE DRAWINGS ARE SUBJECT TOA 690.12 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 0 RENEWABLES ENGINEERING INC. = Curren; — • m Renewaut� TURN RAPID � SHUTDOWN SWITCH TO /� RATED A • " 0 A ' Engineering "OFF�� A V � •' � OPERATING • � • � • CURRENT RENEWABLES ENGINEERING INC. "OFF POSITION TO1760 CHICAGO AVE SUITE J-13 RIVERSIDE CA 92507 PHONE.(951)-405-1733,WWW.CRENG CO SHUT DOWN PV SYSTEM 690.14,690.15,690.54 CONTRACTOR INFO AND REDUCE SHOCK _ HAZARD IN THE ARRAY SECONDPm DUAL POWER SOURCES 51 • • •- VOLTAIC SYSTEM E25Y59j OUTPUT_T RATED AC CURRENT , , . NORMALAC OPERATING • • MAIN SERVICE PANEL RGY LLC. 7470SOUNDNAVENEUE,MATTITUCK, NEW YORK.11952 PH:(631)779 7993 com COMBINER servicesLicence-ME-5.689 69054 AC DISCONNECT (MASTER ELECTRICIAN) Licence OPTIONAL SOLAR LOAD CENTER UTILITY METER 9) m—(SUFFOLK HOMEE IMPROVEMENT) 0 ARRAY PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL MICHAEL RAND PANEL IS AC DISCONNECT PER NEC690.17 1275 BIGHT RD, ORIENT,NY 11957 �/� AHJ TOWN OF SOUTHOLD UTILITY (OPNAGISLANDPOWERAUTHORITY PV SUMMARY INVERTER OUTPUT • • (KWDCM SIZE _ STC 425 X 40 =17.000 PTC 398.1 X 40 = 5.924 • • RELOCATE SYSTEM SIZE NEC 690.31(G)(3)&(4),CRC R324.7 (KWAC) 1280 @240 OVERCURRENT DEVICE MODULES 40 IINKO SOLAR • RNING IIKM425N-54HL4-B (UNLESS BUSBAR IS FULLY RATED) L — MICROINVERTER qp ENPHASE 705.12(D)(2) PHOTOVOLTAIC POWER • ' IQ8MC-72-M-US NOTES: EVERY 10'ON CONDUIT AND ENCLOSURES 1. nec ARTICLES 690 AND 705 AND nec SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Descnption A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR 0 INITIAL DESIGN 8/612024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. A B. RED BACKGROUND COLOR WHITE TEXT AND LINE B WORK. PROJECT# NA C. AERIAL FONT. DATE DRAWN a/a/zoza 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY ER THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE SHEET# PV-60 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. ;.� ENGINEERING DRAWINGS I MECHANICAL CHARACTERISTICS EAGLE Front Side Back ,. ,., a Ss_.,_- t �_L- No.of Halt Cells 10812 z 541 M 0 D U L E S - --- ----_-- --p Dimensions 1722=1134•35mm 167.79-44.65=1.38 inch] M Weight 22 Okg(48 51bs1 THE MOST Front Glass H.gh Tr Anti-Reflection Coating a": � High Transmission,Low Iron,Tempered Glass _ Frame Anodized Aluminum Alloy THESE DRAWINGS ARE SUBJECT TO Junction Box IP68 Rated DEPENDABLE COPYRIGHT PROTECTION S LAW REPRODUCTION IN ANY FORM IS S Output Cables 12 AWG,1400mm 155.12in1 or Customized Length EXPRESSLY FORBIDDEN WITHOUT PRIOR SOLAR^ ^^O D U ^ - WRITTEN APPROVAL FROM CURRENT OLA K PRODUCT IV � Connector 5taubli MC4 RENE WABLES ENGINEERING INC. Fire Type Type 1 - ; Pressure Rating 540OPa(Snow)&240OPa(Wind) Current EAGLE 54HM G6 CIO ) TEMPERATURE CHARACTERISTICS Engineering 420-440 WATT N-TYPE TOPCON I Temperature Coefficients ofPmax -0.29%/°C CURRENT RENEWABLESENGINEERINGINC. v.o 1 Length:i 2mm 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 r""1' Width:32mm Temperature Coefficients of Voc -0.25%/•C PHONE:(951 µ05-1733.NMNJ.CRENG.CO Positive power tolerance of 0-+3% I (1' - - P """* Height:t 1mm I � 9 Temperature Coefficients of Isc 0.045%/°C Row Pitch::2mm CONTRACTOR INFO e ..n Nominal Operating Cell Temperature(NOCTI 45t2•C • NYSE-Listed since 2010.Bloomberg Tier 1 manufacturer - nt - • Top performance in the strictest 3"party labs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS a__ • Automated manufacturing utilizing artificial intelligence Ez SYS9. Current-Voltage&Power-Voltage Temperature Dependence Operating Temperature I•C) -40°C-+85°C • Vertically integrated,tight controls on quality Curves(44OW) of Isc,Voc.Pmax Maximum System Voltage t000VDC ELEMENT ENERGY LLC. Maximum Series Fuse RaLn 25A 7470 SOUND AVENUE,MATTITUCK, M • Premium solar factories in USA,Vietnam,and Malaysia �� m g NEW YORK.11952 s PH:(631)779 7993 r _ s i¢ services@e2sys.com Licenc -ME-52689 ne€ '`" `r (MASTER MALST nee-ELECTRICIAN) KEY FEATURES a ` PACKAGING CONFIGURATION $" (SUFFOLK HOME IMPROVEMENT) O Superior Aesthetics >o l I (Two pallets_One stack) Black backsheet and black frame create ideal Look for • ve 15 m s 31pcs/pallets,62pcs/stack,806pcs/40 HO Container M ICHAEL RAND e s a x; ao residential applications. Voltage IV) " I 1275 BIGHT RD, N-Type Technology O s I ORIENT, NY 11957 N-type cells withJlnk°•sin-houseTOPCon technology E i e x. " '� '" ! WARRANTY offers better performance and improved reliability. Celt Temperature("Cl AHJ TOWN OF SOUTHOLD 25-year product and 30-year linear power warranty OThick and Tough 1•'year degradation not to exceed 1%,each subsequent year not to LONG ISLAND POWER AUTHORITY ��• Fire Type 1 rated module engineered with a thick frame, exceed 0.4%,minimum power at year 30 is 87.4%or greater. UTILITY (LIPA) 3.2mm front side glass,and thick backsheet for added durability. I PV SUMMARY SYSTEM SIZE (D Shade Tolerant ELECTRICAL CHARACTERISTICS (KWDC) STC 425 X 40= ,000 win array design allows continued performance Module Type JKM420N-54HL4-B JKM425N-54HL4-B JKM43ON-54HL4-B JKM435N-54HL4-8 JKM440N-54HL4-B PTC 3981 IX1401=115924 even with shading by trees or debris SYSTEM SIZE 1280 @240 STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT (KWAC) OLAR Protected A ainst All Environments Maximum Power IPmax) 420Wp 316Wp 425Wp 320Wp 430W 323Wp 435Wp 327W 440W 331W MODULES 40 11NKO5N-54 /^•'Q•. g p p p p JKM425N-54HL4-B ty' /rJ' Certified to withstand humidity,heat,rain,marine environments, Maximum Power Voltage IVmp) 32.16V 29.95V 32.37V 30.19V 32.58V 30.30V 32.78V 30.50V 3299V 30.73V ENPHASE 9 MICROINVERTER 40 wind,haltstorms,and packed snow. Maximum Power Current[imp) 13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 73.27A 10.72A 13.34A 10.77A IQ8MC-72-M-US Warranty Open-circuit VoltagelVoc) 38.74V 36.80V 38.95V 37.00V 39.16V 37.20V 39.36V 37.39V 39.57V 37.59V 25-year product and 30-year Linear power warranty. Short-circuit Current(Iscl 13.51A 10.91A 13 58A 10.96A 13.65A 11 02A 13.72A 11.08A 13 80A 11 14A Module Efficiency STC(%1 21.51% 21.76% 22.02% 22.28% 22.53% •STC: a Irradiance 1000W/m' Cell Temperature 25°C (f) AM-1.5 Rev Description Date • 1509001:201501.12litySt2ndartls • 15045001:20180ccupa8onal - _-- 1' ® NOCT: a Irradiance 800W/m' Ambient Temperature 20°C AM=1.5 Wind Speed 1m/s o INITIAL DESIGN 6/6/2024 • IS014001:2015ErnmonmentatStand3rds Health&Safety Standards CE C i#L u3 A • IEC61215.IEC61730 certified products • UL61730 certified products 'Power measurement tolerance:t3% - LISTED e any reserves the final right for explanation onan of the information resented hereby.JKM420-440N-54HL4-B-F7-US SOfQ4 The company y P y pf�^. PROJECT# NA BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US a n= BUILDING YOUR TRUST IN SOLAR.WWWJINKOSOLAR.US Jinl<O DATE DRAWN 8/6/2024 DRAWN BY ER SHEET# PV-7.0 TITLE MODULE SPEC ENPHASE. I08MC Microinverter Comnnonly used module pairings IN 260-460 wModule compatibility To meet compatibility,PV modules must be within the following max.input DC voltage and max.module I. Module compatibility can be checked at https://enphase.com/installers/microin"rtws/calculatw. MPPT voltage range v 25-45 THESE DRAWINGS ARE SUBJECT TO --- _ - -- _-- ----- --_- -- - ------_-_-----—- COPYRIGHT PROTECTION BY US LAW. Operating range v REPRODUCTION IN ANY FORM IS Min./Max.start voltage V 22/66 EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT Max.input DC voltage v 80 RENEWABLES ENGINEERING INC. Max.continuous operating DC currant A 14 Current Max.input DC short-circuit current A 23 Max.module) A 20 Rernewables ----- -- -Overvokage class Ix port II Engineering DC pan backfeedcurm t mA 0 CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PV awry configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit PHONE:(951)-405-1733,WMN.CRENG.CO CONTRACTORINFO Peak output power VA 330 315 Max.continuous output power VA 320 310 Nominal grid voltage(L-L) v 240.split-phase(L-L).180' 208.single-phase(L-L),120` gm®m Q8 M C M i c ro i n ve rte r Easy to install Min./Max.grid voltage v 211-264 183 229 C Z SYS9 Our newest I08 Series Microinverters are the industry's first microgrid-forming`,software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 defined microinverters with split-phase r conversion capability to convert DC and-play connectors power pa ltt1' power to Nominal frequency Hz 60 ELEMENT ENERGY LLC. AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) 7470 SOUND AVENUE,MATlRUCK, application-specific integrated circuit(ASIC).which enables the microinverter to operate in between components Extended frequency range Hx 47-88 - NEW PORK,11952 grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire AC short circuit fault g A 2.70 enera over three senficesoe2sys.com • digital logic and has superfast response times to changing loads and grid events,alleviating cabling Cycles � Licence-ME-52689 Constraints on battery sizing for horse energy systems. (MASTER ELECTRICIAN) Max.units par 20 A(L-U branch circuit' 12 10 Licence-HI-67461 High productivity and reliability Total harmonic distortion <5 (SUFFOLK HOME IMPROVEMENT) Enphase s< Produces power even when the grid is down* Overvoltage class AC port MICHAEL RAND . • More than one million cumulative hours AC port backfeed current mA 18 1275 BIGHT RD, of testing ORIENT NY 11957 Power factor setting to Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure AHJ TOWN OF SOUTHOLD Grid-tied power factor(adjustable) 0.85 leading...0.851aggirg I08 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery.IQ Gateway.and the million cumulative hours of power-on PV modules Peak efficiency x 97A 972 LONG ISLAND POWER AUTHORITY - - - - --- - ---- UTILITY Enphase App monitoring and analysis testing,enabling an industry-leading (LIPA) CEC weighted efficiency x 97.0 98S software. limited warranty of up to 25 years. Microgrid-forming Nighttime power consumption mYY 33 25 PV SUMMARY • Complies with the latest advanced grid SYSTEM SIZE STC 425 X 40= 7.000 MECHANICAL KWDC) support .. PTC 398.1 X 40= 5.924 Ambient temperature range -WC to 65°C(-40°F to 149°F) • Remote automatic updates for the - — ------------ ----------- SYSTEM SIZE 12.80 @240 latest grid requirements Relative humidity range 4%to 100%(condensing) (KWAC) JINKO SOLAR Configurable to support a wide range DC connector type Still MC4 MODULES 40 1KM425N-S4HL4-8 ___... -..__ -._ ENPHASE Connect PV modules quickly and easily IQB Series Microinverters are UL Listed of grid profiles Dintermora IN-W•M Weight: 212mmW31-175 mm(6.9h•302 mm(12"Y t1 kg(2A3 lbs) MICROINVERTER 40 IQ8MC-72-M-US to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans Integrated MC4 connectors. Conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations:Pollution degree Yes;PD3 installed according to the manufacturer's instructions. Enclosure Class 11 double-insulated,corrosion-resistant polymeric enclosure NOTE ---------.----. _-----_- --_.._.- _._._----- -. . • 108 Microinverters cannot be mixed together with Environ.category;UV exposure rating NE"Type 6;outdoor previous geneamons of Enphase m—reverters COMPLIANCE 1,Series.106 sans.etc.)in the same system. Rev Description Date •Meets UL 1741 only when Installed with IG System Controller 2 and 3. 10 Gateway is requred to change the default grid CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 0 INITIAL DESIGN &6/2024 profile at the time of installation to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020.and NEC 2023 section 690.12 and Aurhorfty Having Jurisdiction(AH.)requ—ems. C221-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the nanufaeLrer's instructions. A O 2023 Enphase Energy.All rights reserved.Enphlala,the a and CC logos.'a and certain other marks listed at (1)No enforced DC/AC ratio, httpsi//enphase.com/trademark-usaoe-pwdelines me tradernerks o1 Enpha Energy.lnc.in the US and other countries. (2)Nominal voltage range can be extended beyond nommal if required by the utility. PROJECT# NA Data subject to charge. 108MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 (3)Limits may vary.Refer to local requirements to deflne the number of mlcrolmeneis per branch In your area IOBMC-MC4-DSH-0004aJA-EN-US-2023-10-te DATE DRAWN 8/6/2024 DRAWN BY E R SHEET# Pam%' TITLE MICROINVERTER SPEC THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. ENPHASE IQ Combiner 5/5C REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Deriar�orr pA(.R.A 3)5cm•1a.5 an.6a«n(L.]5'.N5'•8.6T�. WRITTEN APPROVAL FROM CURRENT W.grc yab9safN RENEWABLES ENGINEERING INC. q C«rtrtrrSrttttgf 4wr M�^reEcrci,EwrE 1«^rgn.E re.wvwV�a GV PaCucton ____.. _ __- -_--._--_—._._. .___ /:.ConA•..eS�Y-q+IYL].0-5, nWnV(AMSgQ.20�A3%L Ea�nptcr:m«rwr.g115YAWg8e,r�Ymonwr.9(x25%7. --.-_ _.--.-�_.. .. ............. ...._"._.... Mich.Yr.dv irlGb Aelic,ll. A"'b"'°�"nrg. -aoC w aoc Noswt.rFl g Cw,8vr 5c.MF q Oesa�r Pr oon bwrdtr.ee¢aYd:e+s 9—w P'vd — fey ~�� Current Eµm,ASE nMwvro G/E4i Cl2TO z05%l.mr�.rpmnmmtar^p(r25%)a.dq B.nwvm«b«nq L35%). - _____ -..-. �/q C«.aJvs SC(x_q�rEEF2a0-SCI E�aoe,e_,.+«.nwn.i,aop Outrb«.NLLL<v,�ird,EOM tree 3N Pelturbvwr emwncfa+ Renewables M.b..E+pwse NsbAs Ca,.a R..mRdw(CFIIYOOEEf-,n-OB-Sc-0S)4icxtl...,�..r aolw slrrbbdafl.0 Erna 20A w50A beaswipacMwa AyyG oeoPw cordas«s eo. wd.di4ueatovoAnGmEowmde«, — Engineering WnstO - Arn hrocmbr4 a,w,a:nwvoAMAG�wv��v«s N.,br wdga,d:l4,e LrocePPw ca,e,ctas q GaEnwr Ydw Piatferm tr latalwrwp r'wrwP^o*tr aa,patr.rw.rwnmamenwwrce,v�b A)�asldlo.IRd rm...a,wwr.rdtra.rd�m.>o Erp..1E 7'Sn - — -"-"--""'-"------------ --- ------ -`-"-"---- CURRENT RENEWABLES ENGINEERING INC. 9pAGwWrMMw;yx.tborrgoawrybreskw.ro far Z(IAbrW«bistaEE9 Canmvibtivi(Irr-PYrrY.aer.�9MlY1 B�nM-n CTRl t.u.tl br wrr�lmmm.vMan�rtf�Xrg9arterYSV wdtl�101yR�^CabdiEr BinEa. gkiesYba.wr,wsurdq Bs¢Lerr SP 3/3G.Mp•wed oenw.ir4 comn✓YaUv.b g5��1i�-m�urA 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 q Garewe.Meets Gan bre•Aw.2yda a)A/bA AE.,ui Epwz.eoonw.rs tas3o Ar) PHONE.(951 µ05-1733.WWW.CRENG CO "°"°«R wit.dw+aw-g+d.aeidc«ecT.eeaa+suowaos% CONTRACTOR INFO •. X-ICIAMI-240-5 C_onc, Two c«�n4�«:mwr^Gd•"DCfafiO.a MTtlw Gm..ccvweWw35% MrV�EMS-F Ba2]b/W^IArYnd2A6W/59ir)bavREnYHNdr Owd9.a.y.11�ier�E..-. X-I10-WF240-510 ge.,r.r Cl avn.Eaay.+red..ro a.yrwaeonn erea�.acar.rwa:z3% +R-FMw6m..arrad gmCwrwl C.R.boom Candbawo tr wee camrvevOm wM q SeYwr:Curnaan 3/3G ero,ro q e.ne.vsR LLEal.nnrwptooer4wtl"F IQ Combiner 5/5C Ers+lwr EEdar Co..rcrla+h wn,:gCart.r:SC) KiH,esM ETF-Atl ceelrr nodwe qFJ.LE10CfM-MtO6SPH)S)wahe9 saver T-ibbidW pW IaEr.rwE Ootvr.9�eJ.Ce,SE(wCtlgtllPi'.Lrwr�e.iE.FeotwdE.Edlb.w.wwi0bth. Arcesaorwsart Spwe oorr,ra'n..dwstr,ti coMasYrt-02bord Eqa cb O. ghn.:...a RON �)nc^i.des tO Gatawey wr D:.\yiWi dVDY eolaR Bq TheIOCab-5/5Corbd m .}Qnaospe weand CZSYSA —% 00Swn Iiiad 10 Ciih ,iatan byp.0itli g.m . OIpW Irp,.Mr4utb orboPwmeonad pr k.d-6.t—br rmki—appi-d—10 CerrbYs 55 d C i—w4mcl coro corraeruKation and c of cEueooEwn-06-svos .G-r.>.euE-.n unr.mad.n.�m.sprTaloarem P- L=2,0 Mobbci reL COME-9f-0E4 io BarY3/3T/NIOr.COYbOf-OZtr 0amwd• .mn.raarc.Donnd Y —p tik-with 10SVM—Centrol.r 3y3G.0 IO Batewy 5P irdrden Enph.-li Correct M- �Ar � iATE-ui-11— swa�Arsr yu Rr.r,, ELEMENT ENERGY LLC. Acno PR.n(AP)moda Fore«aweam bwwaw,dw lOObwwY tiro anrotaadsac.raa.ptiw ETphan lTer.w App (CELLMODEM-Mf08-SP-05).only 7470 SOUND AVENUE,MATTITUCK, The lO Cartbher 55C)O writs Mlaoiwertera.lO System Comroier 3/3Q and with 10 combber 5C Suapons F.wn eRzxx srnwns ozuearo GE/aBBTtgLzux Swwscecu,ae.E.rsuz..«as.ms gPO1f, UPwaoC4EYnCka 10Ild—V CT.wdar.s+aAa.9w.CT NEW YORK,11952 Kz Batt.rr sP I.ovlde a wr4leie g:d-.pr�1,c ErWt,ee Er.r9r sre*a^r ca.r e...ee..u+r-,rw-r.n n.a.zit sit Ao. eRzzoe.eRz3ae..ne eazAoe o:�n e..E�. -sr4vata Bwriele rniwartna W so-ro uY PH:-FL m.gwYr wsih,h.nelo-ae..orc Ethernet.«eesdar eoew.En.eee.w..ew� services@e2sys.co.com rovi.Pd®Production notern9 ce�urt.ew.se«a.wew Eron•sei eaa-ax-z-zaov.tart-LSA-z-zaw.eat-zoA-zP-zaw.eaa-LSA-zo-2awHa.anti vet•-zit•-zo- wap,wi se.wwro...sw-..e.a.�..� Licence-ME-52689 2aav-S(e.ae da,.ta n e„e-4r�.w.-.enm) (r avwaw gad.)and lion Eovi w se.Gut.�r rn:Awr maataty sA-SazValEin-Es A.Piiii n erraadaagcRoee�s/sc (MASTER ELECTRICIAN) Licence-HI-67461 AI:-EHV1-P(,'flr.s q Geuwr reWiensrt n�rwa orcu,bona/PCer br q CmEor 5/5C SUFFOLK HOME IMPROVEMEN Fq m Ywal1 lJO-IU-fO-RSA Nde-arvnkrt mr4e*br wiM faun i11-B Serves c.un brWara(wN z+ew.) LL f1Q t]W2S@Z Mn WiL Ta1.0 Cpl.cbt 4C1r6106 oa3,MOIF20F9CA-20W. IQ Th.h,0s EACrOYrvarTers 10 Provide,a Cantrd An 3G bnwkii to Orte still wm,ce,itered gConb.r wam gGalwrwy C_wffi P..*GL12u Iw.ER061fS{g6Y.2ON(LLP 05 3d EdJ.EEE 21)3oSC5D MICHAEL RAND The tam-�wwared vn..c Qd-.e+dr tO saes Prw(das necrogd.c«cor.ecE;on dMce nr.�et: xacowsz cceA-s R.Rra�.�,cows-rtrtm vr.•ea«a.,boa,a(Rce)(«g cac...s/sc e�iw,o�wewrbnr�.o.:g:aNs+eRao.a«.�u.w as tw naa.aa,) M'vawstere(108.Iw_and 106 Serves) WID)fun.i ifY W deterzng mWify the iet Wm Wow. grid f.iarm ard..an,I-*ft it sg Sriii botmm Dark and side the home eneTy system trap gdd pacer tO COi ora Rnno WA w MQ.iwwi.. ne.g2.WIO.swrsl.ttaanwrYrs 1275 BIGHT RD, b.�ry P_ -Supports up w tax 2-pole_ dcuxa fa 240 VAC Pkg4n �tt•rs syawn w,am••,dhea.ra ,zon.o wc.eo.r nayr.a13wrei. Erreoocn,-E�.auooORIENT, NY 11957 — — (, bck,ded) -� -BOAI—PVlxanchc�cuita 0�erraap RSA 10 'n # EP3O0G101 '0130� AHJ TOWN OF SOUTHOLD . iw/l finwerbq gkAq OBIIEwy ENCNARGE-SP-NA.EMCIWIC.E-q-ID-NA EMCH4AGE-3t-9�IA.ENCHIRC.F-,Oi-IDJ4 -Bkwtmth-based WrFi provsiontq Iaeasr W-Raetup A glf m.fbrtarS SCZOODnIC�aMbOI.5C20001nC�Aabp� couNs-cn oz LONG ISLAND POWER AUTHORITY y IErard.uariblsd.rwdlwswrye) V, 2-,—F.wnm+.sw,•.wQ«WIMBngi5«.. g—(M) ^«+Ever geATTEar-51" UTILITY g.i.bl. edYlrotYc4dsA _..- -- (LIPA) IQ Battery 5P 10 Lo.d Controller -Durable NRTL-certmed NEMA tvpe 3a Er•n•n+rrnaierertcn«an a..E...n:q(.poi eoao, A..en gGn..ur a.*E..,.Kw.e PV SUMMARY RdY im g7e !AC baea.y system.Miudes Hdpa prwrrcae.w,ml.ppk.--.,V. encbzure nGweeer trWw nA«SAmno GE'Srnwe/Eam nc4.ded SYSTEM SIZE m fYb+eolaca.bie qeD-enl Mad- g�o,rtapem wib.ie arrw cm�ti«' s 1Kwoc) STC 425 X 40= 7.000 anC wolom,benery life RoOctm n,sawng C 200 A soro cite pe+.AeAse and wee re q Gsvew. -2-veer ldta rdmb„raenKnt program PTC 398.1 1X 40= 5.924 coverage included for both the c«rar _mo—M cl M-20o-ciAEi) AP d2DOAcYmp-shr anedrunM«mwsertcidad wnhrK tv ro Conrb.wr � SYSTEM SIZE 12 80 (9240 a B.n.rt mww„re n 200 A crmP+rrr=,..ws 1-1—tr q earur.mnw�ng Tcwoee wnn,ne b« (KWAC) ® N 0 M uLna1 Leted MODULES 40 "IN KO SOLAR 1KM425N-54HL4-B •cw.,e_w.,.w,....�...a�4e.. Kr�eo,rc�......e...err..we>vrc.,�..u.�,u.o,e,..R.A..w.,.. w,yn w.�.o....w...e.�m ENPHASE MICROINVERTER 40 IQ8MC-72-M-US 5-yeu ll.tW.mrrenty 'FRCW61�apa+lC aarrwr,Y Rrbnetat a�drM,P#�/a9ha...�n.��ns�.Mer-LrefOumw_a/war.�mY P.oa a'ilal W�E:wgr 4.ya.�rwl FyF�awee.e a Yoo.b wwe�ur ome m•rr.. .n 'Fo.wAw��m•boN q Cu�br fa/6C c«roYAry+kM1,M 2-b..�e.r�.�c,ti�bwv.euu n s ._m_n/c.VFl���aeaei+ruMEMrE�eF Yc.nt�e uS ro ovw m.vY. M.aoomNowb.E/mn:drEMrmnm. oee.).•rbwryw K,r}3C-D9,000a�Df.+47$•b6U qC}SC-eln4WW-•MM-iB-24N-aBU '�a Ca,br62Cwnw p.-obob.IM COMe[rt-M iOC-}SCE,-ODOO.an-EN-ue-1u7A-0e-U Rev Description Date 0 INITIAL DESIGN 8/8/2D24 A B PROJECT# NA DATE DRAWN 8/8/2024 DRAWN BY ER SHEET# PV-7.2 TITLE COMBINER SPEC /A IRONRIDGE XR Rail" Family XR RaiIF Family The XR RaiFr Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location,there is an XR Rail"to match. Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in ears, THESE DRAWINGS ARE SUBJECT TO y � _ COPYRIGHT PROTECTION BY US LAW. but the worst storms In 40 years. High winds Capable of - REPRODUCTION IN ANY FORM IS ripping panels from a roof, and snowfalls weighing i EXPRESSLY FORBIDDEN WITHOUT PRIOR PP 9 P 9 9 / WRITTEN APPROVAL FROM CURRENT enough to buckle a panel frame. / _ RENEWABLES ENGINEERING INC XR Rails" are the structural backbone Current preventing these results.They resist uplift, XR10 XR100 XR1000 ienewables protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 Is a heavyweight among Engineering and efficiently transfer loads into the rail.designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle building structure. Their superior _ no snow.It achieves Spans up to 6 feet. wind and snow conditions,while also extreme climates and spans up to 12 CURRENT RENEWABLES ENGINEERING INC. spanning capability requires fewer while remaining light and economical maximizing spans up to 10 feet feet for commercial applications 1760 CHICAGO AVE SUITE J-13 RIVERSIDE CA 92507 PHONE (9511-4051733 WWWVVCRENGCO roof attachments, reducing the 6 spanning capability 10'spanning capability 12 spanning capability number of roof penetrations Moderate load capability Heavy load capability Extreme load capability CONTRACTOR INFO ':� Clear&black anodized finish Clear&black anodized finish Clear anodized finish and the amount of Internal splices available Internal splices available Internal splices available installation time. Rail Selection amm EZSYS9 The table below was prepared in compliance with applicable engineering codes and standards.' Values are ELEMENT ENERGY LLC. + based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B. Roof 7470 SOUND AVENUE,MATTITUCK, Slopeof 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRid e.com for detailed certification letters. H:( 31)7791952 9 9 9 g PH:(631)779 7993 services@e2sys.com Licence-ME-52689 . (MASTER ELECTRICIAN) ... , • • -y'^^,._w • Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Force-Stabilizing Curve 90 MICHAEL RAND Sloped roots generate both vertical and lateral 120 1275 BIGHT RD, None forces on mounting rails which can cause them to ORIENT, NY 11957 bend and twist The curved shape of XR Rails—R 140 XR10 XR100 XR1000 is specially designed to increase strength in both AHJ TOWN OF SOUTHOLD directions while resisting the twisting This unique feature ensures greater security during extreme 160 UTILITY LONG ISLAND POWER AUTHORITY weather and a longer system lifetime 90 (LIPA) PV SUMMARY 120 SYSTEM SIZE STC 425 X 40 = 7 000 20 (KWDC) e 140 RTC 3981 X 40 = 5.924 SYSTEM SIZE(KWAC) 1280 @240 160 MODULES 40 ANKO SOLAR -- - -- -- ----- 1KM425N-54HL4-B 90 MICROINVERTER 40 ENPHASE IO8M30 C-72-1 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 XR Rails"are IronRidge'offers All XR Rails'are made of 6000-series 40 compatible with a range of tiff leg aluminum alloy,then protected with an ` 160 FlashFoot°and options for flat anodized finish Anodizing prevents surface - A other pitched roof roof mounting and structural corrosion,while also providing 80 160 Rev Description Date attachments applications a more attractive appearance � 0 INITIAL DESIGN 6/6/2024 120 160 Table Is meant to be a simplified span chart for conveying general rail capabilities.Use approved certrflcatwn letters for actual design guidance. B PROJECT# NA DATE DRAWN 8/6/2024 2023 IronRidge,Inc.All rights reserved.Visit wwwAronridge.com or call 1-800-227-9523 fcir more information.Version 1.22 DRAWN BY ER SHEET# PV-7.3 TITLE RAIL SPEC IRONRIDGE QuickMountg of Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves y When integrating with a home, solar attachments must be dependable for the lifetime of the rooftop. ' t J _ THESE DRAWINGS ARE SUBJECT TO �../ COPYRIGHT PROTECTION BY US LAW. Due to recent Innovations, many asphalt shingles REPRODUCTION IN ANY FORM IS have bonded courses.A mount that protects without EXPRESSLY FORBIDDEN WITHOUT PRIOR the need to pry shingles Can really speed things up. - - -" . • "^ WRITTEN APPROVAL FROM CURRENT • -♦ � RENE WABLES ENGINEERING INC. Halo UltraGrip-(HUG`) is hereto respect the roof. - Its Halo is a cast-aluminum barrier that encases the Current UltraGrip, our industrial-grade.foam-and-mastic Renewables Seal-This allows HUG to accelerate the installation — Engineering process and provide the utmost in waterproofingHit the rafter?Good to go! no resCURRENT RENEWABLES ENGINEERING INC. protection. Give your roof a HUG.` 1760 CHI SUITE J-13.RIVERSIDE CA 92507 When you find • • -on Place right it It PHONE NE (951}dOS1733.VJVY✓V CRENG CO Only 2 RD Structural Screws are needed. i rafter is found.install 3rd and final screw. secure six screws to deck mount it. CONTRACTORINFO �' Multi-Tiered Waterproofing HUG' utilizes a multi-tiered stack of 0 ffil components to provide revolutionary Trusted Strength & Less Hassle a waterproofing protection.The Hato cast- EZSYS aluminum,raised-perimeter foundation surrounds the UltraGrip base—a foam- Structural capacities of HUG" were reviewed in ckedmasficseal combination that many load directions, with racking rail running ELEMENT ENERGY LLC. prevents water intrusion by adhering sealing with the shingle surface cross-Slope or Up-slope in relation to roof pitch. 7c7o SOUND W YORK,AVENUE. 52TTITUCK, PH:(631)779 7993 Halo uir c For further details. see the HUG certification services@e2sys.com :. F Of Lhe�;; •'�-."- Licence-ME-52689 letters for attaching to rafters and decking. (MASTER` PrOCI UCt I!ne --- - Licence -67461 (SUFFOLK HOME IMPROVEMENT) ——- IronRidge designed the HUG, in combination UltraGrip Seal Technology with the RD Structural Screw to streamline MICHAEL RAND HUG UltraGrip utilizes a state-ot- installs, which means the following: 1275 BIGHT RD, art seal design that uses a unique, . foam-and-mastic combination The-' ORIENT, NY 11957 foam-backed adhesive provides an No prying shingles entirely new flashing system that AHJ TOWN OF SOUTHOLD conforms and adheres to every nook ;1,� Warranty No roof nail interference 25-Year Warran No pilot holes necessary LONG ISLAND POWER AUTHORITY and cranny of composition shingles, P,oduc'._oaranleec bee filling gaps and Shingle step-downs — UTILITY LIPA) (up to 1/8'in height). �Y21�p1(g1Jjd�fBCts No sealant(in most cases) No butyl shims needed PV SUMMARY SYSTEM SIZE STC 425 X 40 = 7.000 (KWDC) ETC 398.1 X 40 = 5.924 Attachment structural Water Seal UL 2703 SYSTEM SIZE (KWAC) 1280 @240 Loading • RatingsJINKO SOLAR MODULES 40 JKM42SN-54HL4-B •r MICROINVERTER 40 ENPHASE Q8 MC-72-M-U S Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG, tothe roof rafters.the roof deck.or both with with our custom-engrneered HUG has been and certified for the UL 441 Section UL 2703 mechanical • • RD(rafter-or-deck)Structural Screw.The RD tested and rated to compliance with 27"Rain Test"and and bonding QTriple Rated&Certified • Structural Screw anchors HUG to the roof support 1004 Ibs of the International TAS 100(A -95 requirements. See to Respect the Roof" c • with an EPDM sealing washer,completing pp ( ) ) u Rev Description Date UL2703,441(27) the stack of waterproofing barriers.See uplift and 368 (Ibs) Building Code 8 "Wind Driven Rain Flush Mount Manual o INITIAL DESIGN 86/z024 Intertek TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. A B G" L NA TWE 8/6/2024 0 • r ER PV-74 TITLE ATTACHMENT SPEC