50479-Z
*°f SOUly°�° Town of Southold * * P.O. Box 1179 woe 53095 Main Rd vl a Southold, New York 11971 CERTIFICATE OF OCCUPANCY No:' 45819 Date: 12/11/2024 THIS CERTIFIES that the building ALTERATION Location of Property: 1415 Harbor Ln Cutchogue, NY 11935 Sec/Block/Lot: 97.-6-10 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/21/2024 Pursuant to which Building Permit No. 50479 and dated: 03/26/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Alterations consisting of a finished basement (no bedrooms) and a conditioned attic storage loft, at an existing single-family dwelling as applied for. The certificate is issued to: Neal Bauman ,Kellie Ferguson Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 150479 11/04/2024 PLUMBERS CERTIFICATION: Derek Hennessey 11/07/2024 Au ho ' d Signature �S�fFei�co TOWN OF SOUTHOLD �o BUILDING DEPARTMENT y TOWN CLERK'S OFFICE • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50479 Date: 3/26/2024 Permission is hereby granted to: Daley, Eric 23 Schoolhouse Ln Morristown, NJ 07960 To: construct alterations to existing single-family dwelling as applied for. At premises located at: 1416 Harbor Ln, Cutchogue SCTM #473889 Sec/Block/Lot# 97.-6-10 Pursuant to application dated 2/21/2024 and approved by the Building Inspector. To expire on 9125/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $595.00 CO-ALTERATION TO DWELLING $100.00 Total: $695.00 Building Inspector o��OF SO!/��ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 97 1-0959 Jamesh _southoldtownny.yov 4iJNTY, �1 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Niel Baumann Address: 1415 Harbor Lane city:Cutchogue st: New York zip: 11935 Building Permit#: 50479 Section: 97 Block: 6 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Neil Coleman Electric Electrician: Neal Coleman License No: ME-4928 SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor Pool New Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 600a Heat Duplec Recpt Ceiling Fixtures 5 Bath Exhaust Fan 2 Service 3 ph Hot Water 30a GFCI Recpt Wall Fixtures 3 Smoke Detectors 2 Main Panel 3 200 A/C Condenser Single Recpt Recessed Fixtures 12 CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan 2 Combo Smoke/CO 1 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump 1 Other Equipment: 2 washers, 2 1 Oft Electric baseboards,1 3ft electric baseboard, 1 6ft electrc baseboar Notes: BASEMENT RENO Inspector Signature: Date: November 4, 2024 1415 harbor In 11;�Calsf fat Town Hall Annex Telephone(631) 765-1802 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 ps- BUILDING DEPARTMENT NOV - 7 2024 1 TOWN OF SOUTHOLD B�TK L D I N C,2):,,zy T. 7,1 Q;'Vi 1,N S 0 UT, jv 0 1 CERTIFICATION Date: Building Permit No. J 0 ( q Owner: (Please print) Plumber: (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers Signature) Sworn to before me this day of 20,:)* 0—,b,Aft^/ —k eXA1161\ CONNIE-D.BUNCH Notary Public,State of New York No.01 BU61 86050 Qualified In Suffolk County Notary Public, County Cornmisslon Expires April 14,'2)� 50M o�afjf s0 yO TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING : FRAMING /STRAPPING [ ] FINAL [ ] .FIREPLACE &.CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 2h 'elup-hlKq DATE INSPECTOR OF 50GlHp� <��� Li # # T6 N OF SOUTHOLD BUILDING_ DEPT. �31-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR' [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ]-.FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION . [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Uoa r�N DATE INSPECTOR. 5 oF souryo� * - TOWN OF SOUTHOLD BUILDING DEPT.- c OOrm��'ao 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ s'ULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [. ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT-CONSTRUCTION [. ] FIRE RESISTANT PENETRATION [ ] .ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: f S U' �✓� OK-. I�- GaUe'ez - DATE 8- 5 — 7` INSPECTOR . OE SOUTyO6 5 �5 C / a�oar 4 tV # # TOWN OF SOUTH . LD BUILDING. DEPT. 631-765-1802 1NSPECTIO N [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] -FIRE SAFETY INSPECTION- [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) . ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ,BkSev�.evr. J DATE l " 4c2L( INSPECTOR SO(/Ty�lo * TOWN OF SOUTHOLD.BUILDING-DEPT. "coum, 631-765-1802 . -INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ _] FOUNDATION 2ND_ [ " ]:INSULATION/CAULKING . [ ] FRAMING /STRAPPING FINAL X45. [ ] FIREPLACE &.CHIMNEY [ ] °FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION . [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 5j d e q_ _cAga44nc_k- +0 4_ ►it s .-h 1 u4hi DATE lv INSPECTOR Final Inspection Checklist nn amended plans for all changes AAe,& -1V C'z4A / �vO�7ll�S errn.�r blower door and manuals AS bu"AAL" / n HD green stamp - G2' -- e664' f 1 % h p Truss placard G plumber solder electrical certificate fixtures installed? appliances installed? running water? V HVAC running? • shut off switch door knobs installed? railings and banisters? Gripable? 61/4" max perimeter -clean and safe? —�house number posted? heat pipes insulated? basement dry? columns bolted? stormwater control? Runoff contained;finish grade contained? relief valve hard piped to 6"? smokes&COs? �--� self close @ garage? �- storm shutters? garage heat detection �—protection of basementfloors fall protection energy certificate on panel generator transfer switch at panel and at unit(permit needed for generator) light bulbs-90% LED required dishwasher hose secured? exterior trim (pine) painted or sealed vacuum system-in garage cant be plastic thermostats must be programmable pool? -door alarms,window restrictors hvac ducts unobstructed and free flowing AIMEE LOPEZ ARCHITECT, AIA 822 LINCOLN PLACE,#2 1 BROOKLYN NY,11216 IT.917.549.4282 NOV 2 0 2024 November 10,2024 TC 'A'�V Southhold Building Department 54375 NY-Route 25 Southhold NY 11971 Re: 1415 Harbor Lane Cutchogue, NY 11935 New York, NY Building Permit#47108 Attn: Amanda Nunemaker I have inspected all plumbing below the slab as indicated on permit number#50479 and it meets New York State Code. Sz Aimee Lopez, R.A.AIA EDo A 32 wr '! — fAIRw a � e r •— W t * bra r r .,� .. ,me.µ. �• . 11- �. domoo woo M� x AP lip ?. of, rat 4«dOo r a Yp;;.i. Nt 7 r i �► ''M�,,s 1-v".'�¢,e',f ✓17i✓ ;�, .+'� `+` .N � �!„t' �-•9•j`. It =� ��:r'�'s�^,C... •�4 .71 r r ,ter TY IA all 41� Ik ow r a r K V f� W,� i r. I'll Al L' el h�+ -41 vl „I, � `}'. Si l i d ii✓✓"•',ey-.' R. I �+f�'Y f. r• y x- a� 6wo * yv'pi}j�'v�I•�r::� ♦ - a \�;F-.�� ;r 1 R ��. �� w '•}�tea ,�y�". � �`Tti - •� ti '�,a w + '�:�c4� 3�'.'t, 4 '� t 'c�!3►'���'1Y_- -..+lay''...i k y'^vM►'►.` i'�:�C."`Sw� ,.' `'ice°_ ✓:' r�r+' � r r t;.' r1 i � v • ls� ,' .•t�';J `/".i��7C1��T � � `a�.. � " � �` 4�� �`i� >. am.y ��.�- c`?_i ''Cr� ,'Z..7?;i� •w' .X - •• .�w"� �� V t .� ..c T.�o� Y�•'��M Y �'{' �l• ` T� 't 'ram a �`�y':•](.�_ tt •�`�a iu "^ Ku t�� t � w"1rt1 l ,L�..-i7�,fl►j� :a �• �r+�'7L., w ." _ �`.1,a•'�� ,.1 � t},� r�r„'( -may+F` *� � �'! 1 ,a _i✓' w i ♦ .ate - �• ■ �_��"�� ,Y, ,• : i � r hr: f 1.. � .J w _ -mil E. �.,•.. w Vill TAW 41 AM 5 f�: is - �, �� •. N RIV t r r yam• �, • __ r .s Air 14 � 1 ... Jj 4; , Or to ia� •, AN AO t • " A 'Rk t ,,' . ..a 1 k { �I l s t '1 ti . � r Y , f� Ar 1V e . 1 ir1r 1 f ,' '. �'�►.rr°'�!'.- ^ram � .. '/��" �` . w� --r 6t � 1. �' �� � 6R M 4^�y / l � o '' � .. ". f � � � � �� �.., ,�_ �� � � - Ltd � � .��a * � �.,. } �`` ` � A F ,� �. �,- -� P. , # � ' �r ;,� � . + � a _� ��' . __ �. ' ..,,:- _ # ., .. _. '. �ti� � � � . :. M Id lb lop Vann W. & 4 1 t a , � vf��y �r W •�C/ i v t Isms S_ r ° M', f✓ 41 s a` Oilt _s t: f l FIELD INSPECTION REPORT DATE COMMENTS O '9 FOUNDATION (1ST) J H ------------------------------------ � C FOUNDATION (2ND) ee ih //7 s/,0c h 'v1vA4,1.w1w ir lvrrahi' 2essvrc ��s !�. , D� � H ROUGH FRAMING& 4?7a An V • PLUMBING 1 v/ -on Dh , D cove-2. C �r INSULATION PER N.Y. rr STATE ENERGY CODE •�•d2 U ` so C LT FINAL ' ADDITIONAL COMMENTS 9 Co41 .-9 .coo / J b 16D t t-7 # ! ! -Wloo fo( c o RZ It- �k• 2`fp le _r . , m 1• PI m s t Ce.' . - !' h. Cer H l� O z H x d b H SufFock TOWN OF SOUTHOLD—BUILDING DEPARTMENT H Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 ?y o! Telephone(631)765-1802 Fax(631)765-9502 hops://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT or Office Use Only PERMIT NO. 56-� � Building Inspector: Z F E R 2 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an ?9!d>t`= 7eiic �tce nis Owner's Authorization form(Page 2)shall be completed. -town o `3,oL.l-iold Date: OWNER(S)OF PROPERTY: Name: Neal Baumann + Kellie Ferguson SCTM#1000- 97-6-10 Project Address: 1415 Harbor Lane- Cutchougue NY 119356 Phone#: 917.371.3695 Email:nbaumann@mac.com Mailing Address: 137 Duane Street Apt 3C- NY,NY 11013 CONTACT PERSON: Name:Jason Michael Fay-Agent Mailing Address: PO Box 74-Mattituck Ny 11952 Phone#:347.463.3168 Email:jason@readestreetstudio.com DESIGN PROFESSIONAL INFORMATION: Name:Aimee Lopez-Architect Mailing Address: 822 Lincoln Place Apt2-Brooklyn NY 11216 Phone#: 927.549.4282 Email:amee@aimeelopezarchitect.com CONTRACTOR INFORMATION: Name:TBD Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition 2Alteration 211epair ❑Demolition Estimated Cost of Project: ❑Other $400,000 Will the lot be re-graded? ❑Yes ONo Will excess fill be removed from premises? ❑Yes 2No EXISTING HOUSE TO BE RENOVATED/MODIFIED IN EXISTING FOOT PRINT+SHELL -NO MAJOR CHANGE TO EXTERIOR REPLACEMENT OF EXISTING SLIDING GLASS BASEMENT DOOR-SOME REPAIR TO EXISTING EXTERIOR STAIR+WALKWAYS INSTALLATION OF EXHAUST FANS ON ROOF- DEMOLITION OF EXISTING BUILT OUT BASEMENT -RECONFIGURASTION OF EXISTING MECHANICAL SYSTEMS -MINOR EXISTING KITCHEN RECONFIGURATION-DEMOLITION OF SECOND.FLOOR/MEZZANINE/ATTIC SPACE TO BECOME LEGAL STO GE PROPERTYINFORMATION Existing use of property: RESIDENTIAL Intended use of property: RESIDENTIAL Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R80 this property? ❑Yes 21No IF YES, PROVIDE A COPY. ® Check Box After Reading: The owner/contractor/,design professional Is responsible for all drainage and storm water Issues.as provlded by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,,for the construction of buildings, additions,.alterations or for removal.or demolition.as herein described.The:applicant agrees to cornply with all applicable laws,ordinances,bullding,code, housing code and regulations and to admit authorized inspectors-on premises and In bullding(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(pri t nam ): JASON MICHAEL FAY ®Authorized Agent ❑Owner Signature of Applicant: Date: Z ,Z \ •�� STATE OF NEW YORK) SS: COUNTY OF being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above n ed, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and r that the work will be performed in the manner set forth in the application file t ewith. Sworn before me this 11 rday of 20 MA Notary Puk ic- - CE NOTARY PUBLIC, ATE OF NEW YORK Qualified Suffolk County PROPERTY OWNER AUTHORIZATION Registration j Noon ires March 89 0 (Where the applicant is not the owner) I� NEAL BAUMANN + KELLIE FERGUSON residing at 1415 HARBOR LANE, CUTCHOUGE, NY 11935 do hereby authorize - JASON MICHAEL FAY to apply on my •� alf to the Town of Southol Building Department for approval as described herein. 7 F /1-:5 t/ Owner's Signat re Date AI 4L Sau�y A0 &2 r",Z 0.0f Print Owner's Name 2 C � a � ® S�FFDI'/ BUILDING DEPARTMENT-Electrical` Spector _ 2024 Gym TOWN OF SOUTHOLD , �UL o ft Town Hall Annex- 54375 Main Road Box 1179 o . Southold, New York 11971-0959nUilding Department Telephone (631) 765-1802 - FAX (631) 6�0QM1 Souta°ld jamesh(cDsoutholdtownny.gov— seandcd-)southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali Information Required) Date: June 26,2024 Company Name: Neal Coleman Electric Electrician's Name: Neal Coleman License No.: ME-4928 Elec. email:info@Nealcolemanelectric.com Elec. Phone No: 631-369-7239 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 3619 Middle Country Rd Calverton, NY 11933 JOB SITE INFORMATION (All Information Required) Name: Baumann Address: 1415 Harbor Lane Cutchogue, NY 11935 Cross Street: Road C Phone No.: 631-369-7239 BIdg.Permit#: 50479 email:info@Nealcolemanelectric.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Minor renovation and finished basement wiring. New 600 AMP service underground S•oo Square Footage: la ;J Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑✓ Rough In ❑ Final Do you need a Temp Certificate?: s/ YES NO Issued On TG�'P a 'le ❑ ❑ ' -�--1�3 11a1 Temp Information: (All information required) Service Size�1 Ph❑3 Ph Size: 600 A # Meters 1 d Meter# ❑✓ New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect Kderground❑Overhead # Underground Laterals M 1 ✓2 ✓ H Frame n Pole Work done on Service? ✓ Y N Additional Information: PAYMENT DUE WITH APPLICATION 7 ( t IN Pd 4115 Q C 4110'7815 y2e, c, )o-�&59 BUILDING DEPARTMENT-Electrical spector TOWN OF SOUTHOLD' jut' V4 f =` Town Hall Annex - 54375 Main Road Box 1179 ' Southold, New York 11971-095 ading nepay"t Telephone (631) 765-1802 - FAX (631) T6$,,,9W �[ v wnn .. of )amesh(a�southoldtownny Gov � seand(�seuth�ldte v N APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: June 26,2024 Company Name: Neal Coleman Electric Electrician's Name: Neal Coleman License No.: ME-4928 Elec. email:info@Nealcolemanelectric.com Elec. Phone No: 631-369-7239 El request an email copy of Certificate of Compliance Elec. Address.: 3619 Middle Country Rd Calverton, NY 11933 JOB SITE INFORMATION (All Information Required) Name: Baumann Address: 1415 Harbor Lane Cutchogue, NY 11935 Cross Street: Road C Phone No.: 631-369-7239 Bldg.Permit#: 50479 email: info@Nealcolemanelectric.com Tax Map District: 1000 Section: q7 Block: 0 Lot: V© BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Minor renovation and finished basement wiring. New 600 AMP service underground Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO Rough In El Final. � Tbm? e ,�%e� y Do you need a Temp Certificate?: 0 YES ❑ NO Issued On �+E-�"1�3 ••1 �`�•��- Temp Information' (All information required) Service Size�1 Ph�3 Ph Size: 600 A # Meters .1 d Meter# 21 New Service[]Fire Reconnect[]Flood Reconnect❑Service Reconnect nderground❑Overhead # Underground Laterals 1 ✓2 ✓ H Frame Pole Work done on Service? ✓ Y N Additional Information: PAYMENT DUE WITH APPLICATION -7 ( ( 04 Pd . 5 ffC41107815 PERMIT# Address: Switches �� Outlets G F I's —i-�I� Surface `4 ` � Sconces 1 Ll HH's UC Lts Fridge HW l POOL Fans It Mini Fr. W/D-,o2 Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV t` HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have )J Used Commentero7y0 (/ 13 T l cat 6 � bbqr� 600 AIM 5�r� a G 5 cQ00 AKA taKe- t 5 ACORV CERTIFICATE OF LIABILITY INSURANCE DATE(MMiDD1YYYY) 06/17/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Alexis D'Angelo NAME: Pro Insurance Agency,Inc. PHONE No, , (631)361-5005 ac No: (866)888-0900 21 Bennetts Road AD ss: certificates@hpproins.com Suite 202 INSURER(S)AFFORDING COVERAGE NAIC# Setauket NY 11733 INSURERA: Allied World Assurance Co Inc 19489 INSURED INSURERS: Clifford Woolley Construction Corp. INSURERC: 153 Powell Ave INSURER D: Bldg 1 Unit 6 INSURER E: Southampton NY 11968 INSURER F: COVERAGES CERTIFICATE NUMBER: MASTER 24-25 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMEDABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN iS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, TR TYPE OF INSURANCE g D POLICY NUMBER MMIUDC EFF MMlD Y P LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENC 50,000 E $ 1,000,000 CLAIMS-MADE ©OCCUR PREMISES Ea occurrence $ MED EXP y one person) $ 5,000 A 5061059300 10/25/2023: 10/25/2024 PERSONAL BADVINJURY $ 1,000,000 GEN'LAGGREGATE UMITAPPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY El PRO- LOC PRODUCTS-COMPIOPAGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ e accident) ANYAUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (per 'e $ UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION I PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETORIPARTNERIEXECUrIVE ❑ NIA E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached It more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold Building Dept ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Main Rd. PO Box 1179 AUTHORIZED REPRESENTATIVE Southold NY 11971 O 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE r ^^"A^^ 113030839 CLIFFORD WOOLLEY CONSTRUCTION CORP 163 POWELL AVE UNIT 6 ' SOUTHAMPTON NY 11968 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER CLIFFORD WOOLLEY CONSTRUCTION CORP TOWN OF SOUTHOLD BLDG DEPT 153 POWELL AVE UNIT 6 54375 MAIN RD SOUTHAMPTON NY 11968 PO BOX 1179 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12613 602-8 906909 05/09/2024 TO 03/01/2025 6/18/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2613 602-8, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT Clifford Woolley CLIFFORD Woolley CONSTRUCTION CORP A ONE PERSON CORP THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. BY CAUSING THIS CERTIFICATE TO BE ISSUED TO THE CERTIFICATE HOLDER, THE POLICYHOLDER UNDERTAKES TO PROVIDE THE CERTIFICATE HOLDER 15 CALENDAR DAYS' NOTICE OF ANY CANCELLATION OF THE POLICY. NEW YORK STAT SUR NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:22404228 U-26.3 FRENCHWOOD° GLIDING PATIO DOORS WATCH" P a 0 T E C T 1 0 N Table of Frenchwood®Gliding Patio Door Sizes Scale 1/8"(3)=11-0"(305)-1:96 Door Dimension 2 83/8" 4'-111/4" 4'-111/4" 9'-9" 9'-9" (822) (1505) (1505) (2972) (2972) Mlnlmum p,_9, 5,_0 - 5,_0, ^--?—9'-10— Flo" Rough Opening _,(838)_ �(1524), �(1524)�_ (2997) (2997) Unobstructed Glass 21118" 211/8" 211/8" 21 Ma" 52" 21 IV 211/8" (single panel only) (537) (537) (537) (537) (1321) 1 (537) (537) Custom-size patio doors are available in 1/s"(3)Increments. 4 heights 4- 11 4- See pages 138-139 for custom sizes,specifications and information on shipping patio FWGD 2968S 5068L 5068R 91068-3 91068-4 doors greater than 95 1/2"(2426). FWGD 29611S 50611L 50611R 910611-3 910611-4 FWGD 2980S 5080L 5080R 91080-3 91080-4 FWGD 29100S 50100L 5010OR 910100-3 910100-4 Door Dimension 3'-23/8" 5'-111/4" 5'-111/4" 11'-9" 11'-9" (974) (1810) (1810) (3581) (3581) Mlnlmum 3'-3" 6'-0" 6'-0"—_ 11'-10" 11'-10" Rough-0pdning (991) (1829) (1829) (3606) (3600) Unobstructed Glass 271/8" 271/8" 271/8" 271/8" 64" 271/8" 271/8" (single panel only) (689) (689) (689) (689) 1 (1626) 1 (689) (689) 4 heights -► -► FWGD 3368S 6068L 6068R 111068-3 111068-4 FWGD 33611S 60611L 60611R 11,10611-3 1110611-4 FWGD 3380S 6080L 608OR 111080-3 111080.4 FWGD 33100S 60100L 6010OR 1110100-3 1110100-4 Door Dimension 3'-83/8" 6'411/4" 6'411/4" (1126) (2114) (2114) Minimum T-9" r-0" T-o" Arrows indicate direction of panel operation as viewed from the exterior.Stationary(S) Rough Opening (1067) (2133) �(213.3) doors Can be Used as an IndlvldU81 patio door Or as a Sidelight.Single-panel patio doors Unobstructed Glass 331/e" 331/8" 331/8" are factory-assembled.Two-panel doors up to 95 1/2"(2426)in height are available (single panel only) (841) (841) (841) unassembled or can be factory-assembled and will arrive at the jobsite ready t0 install. Two-panel doors greater than 95 1/2"(2426)in height and three-and four-panel doors 4 heights -►, are available unassembled only. - Details shown on pages 112-113.Grille patterns shown on page 123: KI FWGD 3968S 7068L 7068R FWGD 396115 70611L 0611R FWGD 3980S 7080L 7080 FWGD 39100S 70100L 7010OR 4'-23/e" 7'-111/4' 7'-111/4" 15'-9" 1 Door Dimension (1279) (2419) (2419) (4801) — - -- Minimum 4'-3" S'-0"-U ^ 8'4" 15'-10" Rough Opening (1295) (2438) (2438) r (4826) Unobstructed Glass 391/8" 391/8" 391/8" 391/8" (singe panel only) (994) (994) (994) (994) -'Door Dimension"always refers to outside frame to frame dimension. -'Minimum Rough Opening"dimensions 4 heights .47 "► may need to be Increased to allow for use of building wraps,flashing,sill panning, a brackets,fasteners or other Items.See Installation information an page 170. •Dimensions in parentheses are in millimeters. FWGD 4368S 8068L 8068R 151068-4 FWGD 43611S 80611L 806119 1510611-4 FWG13 4380S 8080L 8080R 151080-4 FWGD 43100S 80100L 80100R, 1510100-4 110 �ANDERSEN" WINDOWS & DOORS Four Patio Door Heights -� 22 - o 0 FWGDXX68 ©FWGDXX611 ©FWGDXXSO 0 FWGDxx100 Stationary Frenchwood®Gilding Frenchwood®Gilding Patio Door Opening and Area Specifications Patio Door Area Specifications Num-be rol w �ClearOpeninninin Full OpenPosiBon ' " �f "- "'-` Door Panels in Clear Opening Glass Vent `Overall Doar j Door Glass Overall Door Open Number Area Width t Area ( Position Sq.Ft/(mz) Inches mm Inches Height Area Sq.Ft./(m2) Sq.Ft/(m2)J Sq.Ft Area./(m2) I Number Area Area Sq.RAM Sq.Ft./(ml) FWGD5068' 1 11.16 (1.04) 211/4' (540) 751/2" (1918)4 18.61 (1.73) 11.16 (1.04) } 32.71 (3.04) FWGD2968S 9.31 (0.86) 17.86 (1.66)-) E.FWGD6068 _ 1 i 14.31 (1.33). 27 1/4" (692) 751/= (1918) 23.90 (2.22) j 14.31 (1.33) j 39.34 (3.65) FWGD3368S_ 11.95 (1.11) 21.17 (1,97)4 FWGD7068 1 1 17.45 (1.62)'1 33 r/," (845) ) 75 yi (1918) 29.19 (2.71) ;17.45 (1.62) j 45.96 (4.27) -FWGD3968S 14.59 (1.36) ;24.48 (2.27) {FWGD8068" _ 1 It'20.60 (1.91) 39 y4" (997) ; 751/2' (1918) i 34.47 (3.20) i 20.60 (1.91), 52.59 (4.89) -FWGD43685 _ 17.24 (1.60)'127.79- (2.58) } FWGD91068-4 2 j 22.60 (2.10) 431/rs" (1094) 1 751/2 (1918)1 37.22 (3.46) 22.60 (2.10)! 64.59 (6.00) FWGD29611S - 9.73 (0.90) 1•18.50 (1.72) FWGD91068-3 1 ;11.16 (1.04)( 211/4" (540) 751/2" (1918) 41.51 (3.86) i 11.16, (1.04)f 64.59 (6.00) 4GD33611S 12.49 (1.16) 1 21.93. (2.04) FWG691068-3 2 1 22.32 (2.08) 211/,' (540) 751/2" (1918); 41.51 (3.86) i 22.32 (2.08) ( 64.59 (6.00) FWGD39611S 15.25 (1.42) 1 25.37 (2.36) F66111068-4- 2 28.89 (2.68) 1 55 yes" (1399) j 751/2 (1918)i 47.80 (4.44) 28.89 (2.68) 177.84 (7.23) FWG043611S 18.02 (1.67) 1 28.80, (2.68). FWGD111068-3. l L 14.31 (LB) 271/. (692) i 75 y2° (1918)` 52.08 (4.84) 14.31 (1.33)S. 77.84 (7.23) FWGD2680S 11.65 (1.08) 1 21.45 (199)i FWGD111068-3 2 1.28.62 (2.66)i 27 yP (692) i 751/2- (1918)j 52.08 (4.84) 28.62 (2.66) j 77.84 (7.23) FING03380S 14.96 (1.39) 121.94 (2.04) FWGD151068-4 2 41.49 (3.86) 1 791/," (2008) 1751/1". (1918) 68.94 (6.40) 1 41.49 (3.85) }104.34 (9.69) FWGD398OS - 18.27 (1.70) i 29.41 (2.73) ) FWGD50611 1 11.58 (1.08)_1 21114" (540) 1781/16". (1992) j 19.46 (1.81) 7 11.58 (1.08) j 33.89 (3.15) FWGD4380S 21.58 (2.00) 33.39 (3.10) FWGD60611. 1 14.85 (1.38)'j 27 ys (692) i 787/1s (1992),y 24.98 (2.32) 14.85 .(1.38),140.76 (3.79) FWGD29100S n 15.17 (1.41) 1 26.84 (2.49) FWGD70611 _ 1 i 18.12. (1.68)) 331/i (845) i 78 7/rs" (1992)! 30.51 (2.83) ! 18.12 (1.68) 47.62 (4.42) FWGD33100S 19.48 (1.81) 31-.82 (2.96) 1 -FWGD80611- 1 21.39' (1.99)`j 391/" (997) 78.7/1fi' (1992) 36.03 (3.35) 21.39 (1.99)t 54.49 (5,06) FWGD39100S 23.79 (2.21) E 36.80 (3.42) FWGD910611-4- 2 j 23.46. (2.18)'1 43 y1s° (1094) {78'/�a" (1992)( 38.91 (3.61) 23.46 (2.18) 66.93 (6.22) FWGD43100S 28.10 (2.61) j 41.78. (3:88) FWGD910611-3 1 11.58 (1.08)i 211/, (540) i 78 yrs (1992)j 43.39 (4.03) 11.58 (1.08)q 66.93 (6.22) •Dimensions in parentheses are to square meters. FWGD910611-3 2 i.23:16 (2.16) j 211/i (540) i 787/rs' (1992); 43.39 (4.03) (23.16 (2.16) 66.93 (6.22) FIN91110611-4. _ 2 29:99 (2.79)} 55 yrs" (1399) j 78 7/is° (1992)-[ 49.96 (4.64) 29.99, (2.79)j 80.66 (7.49) FWGD3110611-3 1 114.85 (1.38)''f. 27-2/4° (692) 78.7/16"` (1992)j 54.44 (5.06) 14.85 (1.38)j 80.66 (7,49) MGD11106113 2 29.70. (2.76) 1 271/4° (692) 78 1/rs (1992) 54.44 (5.06) i 29.70 (2.76)j 80.66 (7.49) FWGD1510611-4 2 43.07' (4.00),1 79 1/1s (2008) (781/rs". (1992). 72.07 (6.70) 43.07 (4.00) j 108.12 (10.04) FWGD5080 1 13.52 (1.26) l, 21 y4" (540) 91.1/2': (2324) 1 23.31 (2.17) f`13.52 (1.26) j 39.29 (3.65) FWGO6080 1 17.33 (1.61) 271/a (692) j 911/z' (2324) 29.93 '(2.78) 1 17.33 (1.61)1 47.25 (4.39) -FWG07080- 1 21.15` (1.96)_� 331/. (845) 91 y," (2324) 7 36.55 (3.40) j-21:15 (1.96).1 55.21 (5.13) FWG08080 1 i 24.96 (2.32) 1 39 y4" (997) ! 91 y;' (2324){ 43.17 (4.01) !24.96 (2.32) 1 63.17 (5.87) FWGD91080-4 - i 2 j 27.38 (2.54) [ 431/1s" (1094) 91 (2324) 46.61 (4.33) !27.38 (2.54) 1 77.59 (7.21) FWGD91080-3 1 1 13.52 (1.26) 121 y, (540) 1 91 y2" (2324),) 51.97 (4.83) 1 13.52 (1.26)i 77.59 (7.21) FWG091080.3. 2 j 27.04 (2.52)} 211/a° (540) 911/2" (2324)i 51.97 (4.83) 27.04' (2.52) 177.59 (7.21) FWGD111080-4 2 1.35.01 (3.25) 551/1s" (1399) ; 911/2" (2324)) 59.85 (5.56) 35.01 (3.25) f 93.51 (8.69) FWGD111080-3 1 1 17.33 (1.61)3 27 7/. (692) ? 91% (2324) 1 65.21 (6.06) 1-17.33 (1.61)1 93,51 (8.69) FWGID111080-3 2 1 34.66 (3.22) j 271/4- (692) 1 91.1/2" (2324).1 65.21 (6.06) 134.66 (3.22)1 93.51 (8.69) FWGD151080-4 2 1 50.27 (4.67) j 791/1s" (2008) 1 911/2" (2324)1 86.33 (8.02) 1.50.27 (4.67) 1125.34 (11.64) FWGD50100 1 j 17.04 (1.58).1 21 y," (540) i 1151/2- (2934)1 30.35 (2.71) 1,17.04 (1,58)? 49.17 (4.57) - !f FWGD60100 - 1 }21.86 (2.03) ( 27 ye (692) i 115 y2" (2934)) 38.97 (3.47) 1 21.86 (2.03) ! 59.13 (5.49) I FWG070100{ 1 v 26.67 (2.48) S 331/4" (845) 1 115 y," (2934) 1 47.59 (4.24) 1 26.67 (2.48) 1 69.09 (6.42) tt FWGD80100 1 1 31.48, (2.93)} 39 ya' (997) {115 yZ (2934); 56.21 (5.01) j 31.46 -(2.93) 1 79.04 (7.34) FWGD9101004- 2 j 34.54., (3.21)'1 43 y1s" (1094) ?1151h (2934)1 60.69 (5.41) j 34.54 (3.21).j 97.09 (9.02) FWGG910100-3- . 1 ( 17:04 (1.58) 1 21 yP (540) 1151/i (2934)1 67.68 (6.03) ( 17.04„(1.58)1 97.09 (9.02) �MGD910100-3 2 1 34.08 •(3.16)i 211/4" (540) 1151h" (2934)i 67.68 (6.03) {,34.08. (3.16) 1 97.09 (9.02), FWGD1110100-4 2 1 44.16 (4.10)•j 55 y1j (1399) ;115 1/{ (2934) 1 77.93 (6.95) )44.16. (4.10) 1117.01 (10.87) FWGD1110100-3 1 1 21.86 (2.03)! 271/j (692) i 115-/2" (2934)j 84.92 (7.57) (21.86 (2.03) 1117.01 (10.87) FWG61110100-3. 2 !-43.72' (4.06) i 27 1/4' (692) •j 115 1/2" (2934)tc 84.92 (7.57) 1'43.72 (4.06);117.01 (10.87) FWGD1510100-4 2 i 63.41' '(5.89)1 79 y1e" (2008) 1'1151h" (2934) 1112.41 (10.02) {63.41, (5,89) 156.84 (14.57) •Dimensions in parentheses are in millimeters or square meters. 111 PRODUCT PERFORMANCE r WATCH• P R O T E C T 1.0 N Performance Grade,Air Infiltration and Sound Transmission Ratings A-Series Patio Doors with Performance Grade(PG)Upgrades-Low-E40 Impact-Resistant Glass Types For current performance information,please visit andersenwindows.com. ___.._.�___- ----_-.-- - Standard Standartl Glass I Corresponding Glass Sound Duldoor/Indoor f AAMA/WDMA/CSA 101/IS2/'WO Design Pressure TAS 201.202. Transmission Transmission Alr Infiltration Andersen Product ; Performance Grade(PG) (DP) 203 Class(SfQ Class(01TC) CFM/hT' 4 Frenchwood'Gllding Patlo'Door ! Single,Stationary(80) - { Class LC-PG65 Size Tested 50.4"x 95.5" 65/80 _ i 65/70 i 36 , ' 31 <0.2 1 l Two-Panel(611) - i Class LC-PG70 Size Tested 95.3"x82.5" , -70/80� 70/80 31 ! 29 i <0.2 4 Two-Panel(80) - - Class LC-PG70 SlzeTested 95.3°x 95.5° C 70/70 70/70 i 31 .j 29 ( <0:2 r Three-Panel(611) Class LC-PG65 Size Tested 141.0"x 82.5" - 65/70 �� 65/70 t t <0.2 Three-Panel(80) Class LC-PG50 Size Tested 141.0"x 95.5° 1 50/50 50/50 t I t <0.2 I Four-Panel(611) - Class LG-PG65 Size Tested 189.0"x 82.4" 65/70 65/70 _ t t <0.2 i 4.rour-Panel(80) Class LC-PG50 SlzeTested 189.0"x 95.5° j 50/50 ! 50/50 t t f. <0.2 ,f Frenchwood'Hlaged,inswing Patio Door, 'Single,Stationary(611) - Class LC-PG65 Size Tested 38:0"x 82.5" 65/80 1 65/80 ;34 ,� 30 ' <0.2 Single,Stationary(80) 1 Class LC-PG65 Size Tested 38.0"x 95.5" 65/70 65/70 � 34 30 <0.2 - Single,Active(611), Class LC-PG65 Size Tested 38.0"x 82.5° 65/80 65/80 34 30, <6.2 Single,.Active(80) ( Class LC-PG65 Size Tested 38.0"x 95.5" 65/70 1 65/70 .-34 30 <.0.2: iwo-Panel,AP/PA(611) _ + Class LC-PG65 SlzeTested 75.3"x 82.5" ,. 65/80 f 65/80 -33 i 30 ' <0:2 E Two-Panal,AP/PA(80) - - Class LC-PG65 Size Tested 75.3"x 95.5" +, 65/70" 65/70 33 30 <.0.2 Two-Panel,AS/SA/SS(611)" Class LC-PG65 Size Tested 75.3"x 82.5" 65/80, - I 33 30 10.2 Two-Panel,.AS/SA/SS(80) Class LC-PG65 Size Tested 75.3"x 95.5" { , 65/70 ( - 33 30 i <0.2 �-Frenchwood'Hinged outswing Patio Door - •� Single,Stationary(611,80) , Class LC-PG65 Size Tested 38.0"x 95.5" R 65/80 65/80 f -35 I 30 <0:2 Single,Active(611). Class R-PG65 Size Tested 38.0"x 82.5° �• 65/80 65/80 } 35 q 30 <0.2 4 Single,Active(80) Class R-PG65 Size Tested 38.0"x 95.3" I -65/70 65/70 35 30 <0.2 Twa-Panel(611) - _ Class LC-PG65 Size Tested 75.3°x 82.5" 65/80 65/80 34. .3 30 <0.2 1 Two-Panel(80) -. - I Class LC-PG65 SlzeTested 75.3"x 95.5" 65/70 65/70 Z " 34 - 30 ( c0.2 1 Frenchwood'Patio Door Sidelights,&Transoms: " Transom - - i Class LC-PG70 SlzeTested 112.01 x 27.0° 70/80 - 70/80 - t ; t <0.2, 4 Sidelight Transom' Class LC-PG70 Size Tested 18.0"x 27.0" f 70/80 - 70/80 t ' i t '<0.2 i Sidelight(611,80) f Class LC-PG70 Size Tested 18.0"x 95.5" 70/80 70/80 f t i t i c0.2 For a listing of helpful links related to performance,test reports and regulations,visit andersenwindows.com/coastalperformance. •'Performance Grade(PG)"ratings may vary from tested performance rating for larger or smaller units of a particular type. •°Sound Transmission Class(STC)"&"Outdoor/IndoorTransmisslon Class(OITC)'ratings are for Individual units based on Independent tests and represent entire unit.HigherSTC/onC values may be available with other glazings. •This data Is accurate as of October 2019.Due to ongoing product changes,updated test results or new industry standards,this data may change overtime. -Where designated,Andersen products are certified and labeled to the requirements of the Hallmark Certification Program.Actual performance may vary based on variations in manufacturing,shipping,Installation,environmental conditions and conditions of use. •Contact your Andersen supplier or go to andersenwindows.com for more information. •All Impact resistant glass units,except sidelight transom,tested to Large Missile D,Wind Zone 4 and High Velocity Hurricane Zone(HVHZ)requirements of Florida. t Data not available. 162 �ANDERSEN'" WINDOWS & DOORS Performance Grade,Air Infiltration and Sound Transmission Ratings A-Series Patio Doors with Performance Grade(PG) Upgrades—Monolithic Impact-Resistant Glass Types For current performance information,please visit andersenwindows.com. +j- Standani Standard Glass Corresponding Glass Sound OutdpdrJlndoor AAMA/WDMA/CSA 101/152/A440 Design Pressure TAS 201,202, Transmission 7mnsmission Air Infiltration Andersen`Product j Performance Grade(PG) (DP) 203 Class(SfC) Class(ORC) CFM/Fri fFrenchwood'GIIding Patio Door , i Single,Stationary(611,80) — j — i 65/80 + — — 10.2 Two-Panel(fill) — — 70/80 ( — — { <0.2 i Two-Panel(80) ) I — 70/70 — — I <0.2 i Three-Panel(fill) { — — i 65/70 — ! — i <0.2 ! Y Three-panel(80) — t — i 50/50 — ! — <0.2 Four-Panel(fill) 65/70 — I — 4 <0.2 Four-Panel(80) — i — 50/50 i — i — -<.02 i Frenchwood'Hinged Inswing Patio Door - - (Single,Stationary(611) j — — l 65/80 e — — <0.2 i Single,Stationary(80) I , ' 65/70 — ! — ' 10.2 I Single,Active(fill) I — - { 65/80 i — — <0.2 Single,Active(80). - ! — — I 65/70 — <0.2 Two•Panel,AP/PA(611) ` — — ' 65/80 — — 10.2 (Two-Panel,AP/PA(80) l — { — f 65/70 — , — ! <0.2 Two-Panel,AS/SA/SS.(611) i Two-Panel,AS/SA/SS(80) Frenchwood'Hinged Outswing.Patio Door I Single,Stationary(611,80) — 1 — 65/80 — — 1 <A.2 Single,Active(fill) ! — i — 65/80 I — 1 <0.2 Single,Active(80) I — i — 1 65/70 l — — <0.2 { }iwo•Panel(fill) 65/80 — — ! <0.2 Two-Panel(80) - � — � — ! 65/70 ( — ` — <0.2 !Frenchwood'Patio Door.Sidelights&Transoms `Transom — ! — i 70/80 { — — <0.2 Sidelight Transom — — ' 70/80 i — i — k <0.2 I Sidelight(fill,80) 70/80 1 — i — < <0.2 For a listing of helpful links related to performance,test reports and regulations,visit andersenwindows.com/coastalperformance. •"Performance Grade(PG)"ratings may vary from tested performance rating for larger or smaller units of a particular type. •"Sound Transmission Class(STC)"&'Outdoor/Indoor Transmission Class(OITC)"ratings are far individual units based on Independent tests and represent entire unit.Higher STC/OITC values may be available with other glavngs. •This data Is accurate as of October 2019.Due to ongoing product changes,updated test results or new Industry standards,this data may change overtime. •Where designated,Andersen products are certified and labeled to the requirements of the Hallmark Certification Program.Actual performance may vary based on variations In manufacturing,shipping,installation,environmental conditions and conditions of use. •Contact your Andersen supplier or go to andersenwindows.com for more Information. •All impact resistant glass units,except sidelight transom,tested to Large Missile D,Wind Zane 4 and High Velocity Hurricane Zone(HVHZ)requirements of Florida. 163 PRODUCT PERFORMANCE r WATCH' P a 0 T E C T 1 0 H Center of Glass Performance Data-Low-E4®Impact-Resistant Glass For current performance information,please visit andersenwindows.com. %RH Fading Andersen'Product j VT' SC' SHGC3 RHG4 TO, Tdws @center' IGSTe ASerles Windows - - - Casement i 70% -0.47 0.41 j -98 1 <1% 1 23% j 59% I 55°F ;Awning { 70% ( - 0:47 ._I 0.41 f 98 ,( <1% 23% 59% 1 55°F Double-Hung- I 70% ! 0.47 0.41 I 98 C <1% i 23% ' 59% ? 55"F !Stationary Transom 70% 0:47 ) 0.41 97 I <1% 21% 57% 1 '54°F �Venting Transom, ( 70% 0.47 0.41 98 � �<1% 23% 59% 55°F i Picture 70% E 0.47 ` 0.41 ' 97 f <1% ( 21% ` 57% 54°F j Specialty ; 70% 0.47 i 0.41 ( 97 i <1% 6 21% 57% { 54"F �ASerles Frenchwood*PaUe Doors,PaUo DoorTmnsoms&Sidelights and Venting Transom Windows Gliding I. 70% '0.47 1 0.41 ', 97 <1% 21% i 57% 54°F y Hinged inswing 70% ? •0.47 , 0.41 I 97 i <1% 21% 57% 1 54°F j Hinged 0utswing 70% 0.47 0.41 i 97 1 <1% 21% I 57% 54°F l Transom 69% 0.46 0.40 97 i <1% 17% y 57% 54°F Sidelight 70% 1 0.47 1 0.41 i 98 ` <1% 1 21% 57% I 54°F .i i VentingTransom 70% 0.47 0.41 98 <1% 21% 57% 54°F Center of Glass Performance Data-Low-EW SmartSun'Impact-Resistant Glass For current performance information,please visit andersenwindows.com. Fading. %RH Andersen'Product uf' SC' $HGC' RHG4 TUvs Tdwe @center' 1GST8 A3edes-Windows Casement ; 63% 0.32 ? 0.28 67 i <1% 17% 59% j 55°F _ i.Awning - 1 63% 0.32 0.28 1 67 <1% 17% 59% j 55°F i Double-Hung 63% ! 0.32 1 0.28 1 67 <1% 17% 59% 55°F I i Stationary Transom 63% (. 0.32 0.28 67 1 <1% 16% j 57% 54°F j Venting Transom _ a 63% ( '0.32 ( 0.28 j 67 <1% 17% 59% ! 55°¢ i Plcture 63% 0.32 0.28 67 i <1% ( 16% f 57% 54°F 1 Specialty 63% 0.32 i 0.28 ; 67 I <1% 16%. 57% 54°F ASerles Frenchwood'Patio Doors,.Patio'DoorTmnsoms&Sidelights and Venting Transom Windows i Gilding 63% f 0.32 0.28 +; 67 <1% f 16% r 57% 54°F i Hinged Inswing 63% j 0.32 f 0.28 67 <1% 16% 57% Z 54°F i Hinged Outswing 63% I 0,32 I 0.28 + 67 ! <1% l 16% 57% 54°F j Transom ) 63% i 0.32 I 0.28 67 i <1% 14% 59% I 55°F Sidelight .1 63% 0.32 i 0.27 ! - 67 j <1% i 16% I 57% I 54°F f Venting Transom 't 63% 0.32 1 0.27 67 { <1% 16% ! 57% ' 54°F i For a listing of helpful links related to performance,test reports and regulations,visit andersenwlndows.com/coastalperformance. -"Low-E4'°,"low-E4'SmartSun'and"Low-E4-Sun"are Andersen trademarks for"Low-E"glass. •Based on NFRC testing/simulation conditions using Windows v7.3.4.0 and NFRC validated spectral data.0°F outside temperature,70°F Inside temperature and a 15 mph wind. 1)Visible Transmittance(VT)measures how much light comes through the glass.The higher the value,from 0 to 1,the more daylight the glass lets in.Visible Transmittance Is measured over the 380 to 760 nanometer portion of the solar spectrum.2)Shading Coefficient defines the amount of heat gain through the glass compared to a single lite of clear'/."(3 mm)glass.3)Solar Heat Gain Coefficient(SHGC)defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released Inward.The lower the value,the less hearts transmitted through the glass.4)Relative Heat Gain Is the amount of heat gain through a glazing Incorporating U-Factor and Solar Heat Gain Coefficient.5)Transmission Ultra-Violet Energy(TUV).The transmission of short-wave energy In the 300-380 nanometer portion of the solar spectrum.The energy can cause fabric fading.6)Transmission Damage Function(TOW).The transmission of UV and visible light energy In the 300-600 nanometer portion of the solar spectrum.The value Includes both the UV and visible light energy that can cause fabric fading.This rating has also been referred to as the Krochmann Damage Function.This rating better predicts fading potential than UV transmission alone.The lower the Damage Function rating,the less transmission of short-wave energy through the glass that can potentially cause fabric fading.Fabric type is also a key component of fading potential.7)Percent relative humidity before condensation occurs at the center of glass,taken using center of glass temperature.8)inside glass surface temperatures are taken at the center of glass. -This data is accurate as of October 2019.Due to ongoing product changes,updated test results or new Industry standards,this data may changeover time.Contact your Andersen supplier for current performance Information or upgrade options. •Contact your Andersen supplier orvisit andersenwindows.com/nfrc for center of glass performance data on windows with laminated glass,patterned glass,tempered glass and products ordered with capillary breather tubes. 164 1"ANDERSEN`" WINDOWS & DOORS Andersen'NFRC Certified Total Unit Performance(continued) For current performance information,please visit andersenwindows.com. r--® ) ; Andersen'Product r• Impact-ResistantGlass Type'? U-Factor' SHGC= VTo l AndeisenTProduct ;. Impact ReslstantGlassType • I U-Factor' 'SHGCz VT'. i Without Grilles `0:28 0.34 0.56 - - Without Grilles( .0.32 0.24 0.40 w ) Simulated Divided Light Grilles 0.28.- 031 051 Simulated Divided LightGnlles 3 0:32 0.21 0.34 ff 9 Firelight-LightGdlles , 0.30 031 051 ' Flnelight"Light Grilles .0.33 r 0.21 034 , •' Full Divided Light Grilles 0.29 • 0.31 0.51 Full Divided Light Grilles Without Grilles ••0,24;-,l 0.33 • 0.56 .. "x Without Grilles : '0.29 0.23 0.39 Simulated Divided Light Grilles 'b.24" t 0.30 0.50-` Simulated Divided Light Galles .0.29- i 0.20 0.33 , -9 Flnelight Light Grilles 0.25 - 0.30 0 50 -+ 3 s Flnelight light Grilles , 0.30' 0.20 0.33 Full Divided Light Grilles 0.26 0.30 0.50 a Full Divided Light Galles 0:31 0.20 0.33' - A-Series Without Grilles; .0.29° 021 0.30' - Without Galles ',0.32 0.15 0.22 Dlrect-Set Specialty ((( �, Windows c Simulated Divided Light Grilles+.'0.29 - 019 0 27 Simulated Divided Light Galles 0.32 0.13 0.19 1(>3ssu fLto:50eq R a RnelightUghtGrilles �. 0.29; 019 : 027 pSeries Firelight Light Grilles; 0.33 - 0.13 0.19 gr334 m?to'as5 m') Full Divided Li ANo N 12s•. Full Divided Grilles" 0.30 019 0 27 Fienchwood'Hinged` Light Galles . 0.33 i 0.13 0.19 Without Grilles 0.28 - 0.23 ' 0.51. Inswing Patio Doors Without Gilles r _0.32 0.16 0.36 " ZZ ' Simulated Divided Light G011es ,'0.28 0.21 0.45, AND-N-92 j3. f Simulated Divided Light Grilles r 0.37 0.14 . 0.31 « Firelight Light Grilles ' `0'.28, , 0.21 0.45 �.E-'; Flnelight Light Grilles? "0.33•..t 0.14 0.31 Full Divided Light Grilles: 0.29 0.21 " •0.45' " Full Divided Light Grilles '033 0.14 0.31 Without Grilles,`.0:23:`. 0.23 '0.50;-'' - Without Galles ',0:28 0.16 0.35, Simulated Divided Light Grilles .0.23'; 0.20 :0.45. Simulated Divided Ught Grilles ( ;0.28 0.14 0.30 En ; .Firelight Light Grilles 1 0.25 020 045 " 9 es�;`, Finellght Light Grilles i '0.29 0.14 0.30 "3 Full Divided Light Grilles • 0:25 .A '0.20 0.45 Full Divided Light Grilles'`0.31 0.14 0.30 Without Galles '0.30 0.31 t.'-0.50:' • Clear-Without Grilles„"0.67 0.23 0.34- ' v_ Simulated Divided Light Gilles;--0.30 0,27.. ; 0.45- - .-"Clear-Simulated Divided UghtGrilles'. .0.67 0.20 0:29 Flnelight"Light Grilles 0.31:' 0.27 j 0.45 r 11 E Gmy-Without Grilles 0.67 -` 0.20 0.17 ! Full Divided Light Galles Gray-Simulated Divided Light Grille 1 :0.67 0.18 .0.14 Without Grilles e" '10:26 0.29 0.50.':.' , Without Grilles '0.32 ,« 0.24 0.40...'' �Z�,.' Simulated Divided Light.Grilles '0.26 0.26 = 0.44"` w Simulated Divided UghtGrilles' 0.32 `; 0.21 0.34 Firelight Light Grilles 0:27 „ 0.26 { 0.44:•` -,t Flnelight"Light Grilles I '0.33" 0.21 -0.34 - full Divided Light Grilles ' I - .a.' `" = • :� Full Divided Light Grilles . 0.33 ' 0.21 .0.34 A•Sedes - 'SashSeE"Specialty, `: Without Grilles 0.30.- 0.19 0.27 Without Grilles ••0.28-_-,, 0.23 0.39 Windows Simulated Divided Light G411es I 0.30 , 0.17 i 0.24 Simulated Divided Light Grilles :0.28 0.20 0 33 (>3ssq.n.m5osga, 3 Firelight Light Grilles 0.32'.' 0.17 ;, 024 ' _. Finellght Light Grilles .029 0.20 0:33 ' .ara34 m=tq ass m�) 9 Full Divided Light Grilles -:- , •� 3 ' Full Divided Light Grilles .,'0:30 ; 0.20 0.33' + ANo-N,t2a _ Without Grilles•"0.29, 0.21 '0.45 - ,,� Without Grilles 0.32, ' 0.15 ! 0.22 Simulated.Divided Light Grilles;-•0.29 0.19 0.40, ' - �. ; Simulated Divided Light Grilles •0.32'" 0.13 "0.19-- Fnelight Ught Grilles: 0.31: 0.19 ; 0.40 3 I Firelight Light Grilles 0.33 F 0.13 0.19 p Series Full Divided Light Grilles• - ;i French woo A'Hinged Full Divided Light Grilles 0.33. 0.13 , ,0.19, Without Grilles'. 'ME' 0.20 0.47�_� Otitswing Petld Doors,. , Without Grilles +. 0.31 0.17 0.36' S Simulated Divided Light Grilles °0.25 0.18 •0.40 ANo N-o3 7 d'Y. ? Simulated Divided Ugh[Grilles 0.31 0.15 0,31 " Ex,. FinellghtLightGrilles s 0.27. 0.18 040: aN Flnelight LightG411es' •0:32- ` 0.15 031" 3 Full Divided Light Grilles ,;; - Full Divided Light Grilles 0.32' 0.15 0.31.. Without Grilles 0.32 ' 0.26 044 Without Grilles 0.28 0.16 , 0.35 Simulated Divided LJ Gales , 0.32 0.23 018, l I � Simulated Divided Light Grilles '• ,0 28 0.14 0.30 C m Flnelight'Light Grilles' 0.33 r 0.23 0 38'•; 3 s x Flnelight Light Grilles ' 0.29 0.14 0.30, Full Divided Light Grilles 0.33 0.23 038•,.`r N3' Full Divided UghtGdlles -:0.30 r 0.14 0:30_ Without Grilles -0.28 :r 0.25 ,0:43. Clear-Without Grilles i' 0.67• 0.23 0.34• "•- ".3': Simulated Divided Light Grilles - 0.28 ; 0.22 ••0.37. - ' " , or_`.Clear-Simulated Divided Light Grilles t• 9.67.. ; 0.20 r, 0.29' _ • i Flnelight Light Grilles '. 0.29'. .j 022 037"", E.• Gmy-WiNoutGNlles �0.67 0.21 0.17 •' - 3-: Full Divided Light Grilles 0:30 . 0.22 0.37 .+ u' Gray-Simulated Divided Light Grille -.-0.67- 0.18 034. .? _ Without Grilles,- 0.32, + 0.17 •0.24' Simulated Divided Light Grilles , •0.32'., 0.15 0.21 continued on next page -eries - 3- ' Flnelight Light Grilles '-033 '.I 0.15 0.211 Frenchwood'Gllding Full Divided Light Grilles -;0.33 - 0.15 0.21,11 Path)Doors Without Grilles .0.31 0.18 0.40 arlo N so , Simulated Divided Light Grlles ; 0.31` 0.16 '0.34" 9 E. Firelight Light Grilles' -.0.32 --+ 0.16 0.34 Full Divided Light Grilles ', 0.32- + 0:16 :-•0:34 ' " Without Grilles 0.28- t 0.17 ,,0.39-'+ .. Simulated Divided Light Grilles '0.28 .: 0.15 0.33 -9 Firelight Light Galles 0.29` 0.15 t .0.33 ' 3 j Full Divided Light Grilles 0.30•-..' 0.15 f 0.33 E Clear-Without Grilles -0:71 .,` 0.25 0.38 Clear-Simulated.Divided Light Golles' 0.71'r 0.22 0.32 Gmy-WithoutGdlles 0.71 - 0.22 018:'„ Gray-Simulated Divided Light Grille' 0.71. 0.20 .0.16 For a listing of helpful links related to performance,test reports and regulations,visit andersenwindows.com/coastaiperformance. •"Low-E4'","Low-E4'SmartSun`","Low-E4'Sun"andHeatLock'are Andersen trademarks for"Law-E•glass. - 1)U-Factor defines the amount of beat loss through the total unit in BTU/hr/ft?°F.The lower the value,the less heat Is lost through the entire product.Window values represent non-tempered glass.Use of tempered glass can Increase U-Factor ratings.See an dersenwindows.com/nfrc for specific performance values.Door values represent tempered glass.2)Solar Heat Gain Coefficient(SHGC)defines the fraction of solar radiation admltted through the glass both directly transmitted and absorbed and subsequently released Inward.The lower the value,the less heat Is transmitted through the product.3)Visible Transmittance(VT)measures how much light comes through a product(glass and frame).The higher the value,from 0 to 1,the more daylight the product lets in over the product's total unit area.Visible Transmittance Is measured over the 380 to 760 manometer portion of the solar spectrum. •NFRC ratings are based on modeling by a third-party agency as validated by ad independent test lab In com pl iance,with NFRC program and procedural requirements. •This data Is accurate as of October 2019.Due to ongoing product changes,updated test results or new Industry standards or requirements,this data may change over time.Ratings are for sizes specified by NFRC for testing and certification.Ratings may vary depending on unit size,use of tempered glass,different grille options,glass for high altitudes,etc. Vale es are for single units with given pane thickness and 3/4"(19mm)grilles for windows and 1"(25mm)grilles for door products. 167 DRAWING LIST KEY MAP ABBREVIATIONS DRAWING SYMBOLS _ o NOTE FIN Finish ' DRAWING LIST S.C.T,M. # DISTRICT:1000 SECTION:97 BLOCK:6 LOT:10 R-80 DWELLING ABV Above PVC Polyvinyl Chloride Q w AC Air Conditioner FLR/FLR'G Floor/Flooring R&S Rod&Shelf �'— BUILDING ----------------- SETBACK LINE ISSUED-DOB ACT Active F,0 Face Of R/RAD Radiator SECTION T-100 TITLE SHEET,DRAWING LIST+SITE PLAN o AD Access Door FPSC Fire Proof Self Closing F— z RD Roof Drain V J 2 ADJ Adjustable RG Footing REF Refrigerator WALL 0 W WASTE STACK Y o AFF Above Finished Floor H Fin Tube REINF Reinforced = C D-100 DEMOLITION PLAN AP Access Panel G Gas SECTION U ISSUED-DOB RE61'D Required APP OVED AS NOTES Q BD Board Galy Galvanized —1 0 LID LEADER DRAIN � BEX Bath Exhaust GC General Contractor RM Room ��` ENLARGED OA •3 F'# Sd # w a0�j�25 BO Bottom Of GYP BD/GWB Gypsum Wall Board RV Roof Vent DETAIL/PLAN Q Q A-100 BASEMENT CONSTRUCTION PLAN+CONSTRUCTION DETAILS ISSUED-DOB BRG Bearing Hz0 Water S Sink O FD FLOOR DRAIN �- �i BT Bidet HD Head SC/SL Self-closing/ XX X EXTERIOR FEE J 6C� BY: O Q w A-101 FIRST FLOOR FRAMING AND MECHANICAL PLAN ISSUED-DOB HM Hollow Metal kf-latchin NOTIFY BUILDING DEPARTMENT AT J BTM Bottom SD Shower Dram ELEVATION O V VENT STACK 631 765-1802 8AM TO 4PM FOR THE W A-102 FIRST FLOOR CONSTRUCTION PLAN+CONSTRUCTION DETAILS ISSUED-DOB CAB Cabinet HP High Point SD/CM Smoke&Carbon X SECOND FLOOR CONSTRUCTION+ROOF PLANS ISSUED-DOB CBU Cement Backer Unit Hot Water Heater ROOM NAME FOLLOWING ION ECTIONrS: w o A-103 S CL/CLOS Closet IM Ice Maker Monoxide Detector X XX X INTERIOR CONSTRUCTION PLAN 1. FOUNDATION-TWL►Rc nr''�FD CLG Ceiling INSUL Insulation SE Security ELEVATION FLOOR FINISH FOR POURED CONIGR"'TE: Q N CMU Conc.mas,unit INT Interior Sim Shower X r n P,,, SIM Similar ROOM NAME 2. ROI.GH-FRAMi,aG& PLL: 'F�i��..i A-200 BASEMENT REFLECTED CEILING+ELECTRICAL PLANS ISSUED-DOB F� CNTR Center JMB Jamb ELEVATION REFLECTED CEILING PLAN 3. INSULATiON CONIC Concrete RV/L Lavatory ST/STL Steel - CEILING FINISH 4. FINAL-CONSTRUCTION MUST F� STV Satelite INDICATOR JS Jamb Switch A-201 FIRST FLOOR REFLECTED CEILING+ELECTRICAL PLANS ISSUED-DOB o Fs� CS Clinical Sink STEX Stove Exhaust BE COMPLETE FOR C.O. o A-202 SECOND FLOOR REFLECTED CEILING+ELECTRICAL PLANS ISSUED-DOB CONT Continuous MAH Mahogany T Toilet 90 MC Medicine Cabinet TB Towel Bar DXX DOOR AND FRAMED ---------H2O--------WATER LINE ALL CONSTRUCTION SHALL MEET THE —� CT Ceramic Tile CREST Crestron MECH Mechanical Telephone OP'G NO. REQUIREMENTS OF THE CODEC OF NEW —� PORK STATE. NOT RESPONSIBLE FOR 0 CTV Cable MIN Minimum D Dryer Mnfld Manifold � Top Of XX LP--- ------ LIQUID PROPANE GAS LINE DESIGN OR CONSTRUCTON ERRORS � � DH Double Hung Toilet Paper Holder WINDOW N0, M.O. Masonry Opening TR Towel Ring DIM Dimension WD Mounted TRANS Transparent COMPLY WITH ALL CODES OF en o DR H Door Head W ----------WASTE LINE o DTL Detail ►+ L Metal TYP Typical CABINET ITEM NEW YORK STATE &TOWN CODES12�LU w CONSULTANT DW Dishwasher NAT Natural UON Unless Otherwise Noted AS REQUIRED AND CONDITIONS OF w DWG Drawing NIC Not In Contract VCT Vinyl Composition Tile ----------PP-------__._ PERFORATED DRAIN PIPE e� «� OC On Center —•---•—• , � w DWR Drawer �' N ZBA w � Q OFE Owner Furnished SURVEYOR �, E Electric Equipment W Washer Field CENTERLINE SOUfHOLLDD�06VN PLANNING BOARD 113 '0 ��> KENNETH WOTCHUCK EA Each WA Waste �� S STORM DRAIN PROPERTY OF: �, EL/ELEV Elevation 0FCI Owner Furnished WC Water Closet ALIGNMENT SOLI HO' EON/N TRUSTEES L PO BOX 153 NEAL BAUMANN+KELLI FERGUS &Contractor Installed WD Wood EP Electrical Panel N,YS.D' AQUEBOGUE NY 11931 1415 HARBOR LANE EQ Equal 'OPP H Opposite Hand WDWK Woodwork DIRECTION OF MATERIAL HB HOSE BIB SO LD HPO OFFICE: 631,298.1588 CUTCHOUGE NY 11935 EQUIP Equipment ik LAM Plastic Laminate WH Window Head EXSTG/EX Existing If1YWD W.O. Wall Oven Plywood HHS HOSE BIB W/HAND HELD EXP Exposed IK)P Poplar VS Vent Stack -________- CONSTRUCTION SPRAY REVIEWING STRUCTURAL ENGINEER EXT Exterior IT Pressure Treated BELOW —0 GAS All exterior lighting JOSEPH FISCHETTI,PE ID Floor Drain NTD Painted 1725 HOBART ROAD FAI F ----- Fresh Air Intake — CONSTRUCTION —— EXISTING OCCUPANCY OR re airled led shal con o0 SOUTHOLD,NY 11971 FF Finish Floor ABOVE CONTOUR USE IS UNLAWFUL to Chapter 172 OFFICE: 631-765-2954 — — —'— PROPERTY LINE --'--' NEW CONTOUR WITHOUT CIERTIFICATC of the Town Code U,O,N, OF OCCUPANCY SITE PLAN- 1 :20 PLUMBER CERTIFICATION ELECTRICALUJ . I ON LEAD CONTENT BEFORE INSPECTION REOUIR CERTIFICATE OF OCCUPANCY SOLDER USED IN WATER SUPPLY SYSTEM CANN0 EXCEED 2110 OF 1% LEAL. Blower door and ductwork testing required. LAND OF WILLIAM & ELEANOR FO TE ,. PLOMBINC-1 ALL PLU"12-IN a WAS'7E L N I LAND OF PETER C. NEED ,, , STERLING &WATER LIMES TIDAL WETLAND BOUNDARY AS CD N TIIr� . F.aRE.C©v �Int>a ; ' DELINEATED BY EN-CONSULTANTS N 67046'00" E II 4'WIRE FENCE ALONG LINE 542,00' DEC, 22, 2016 '—'2'Nx x x x x x x x x x x x x N,2N Must provide M,anua]s TIMBER WALL O/L D, J and S as per NYS Energy e Cod s z I LLJ WELL y N \ o FRM,GARAGE r Q 6 � o W/LOFT ; ! CP o E f FRM• 8 � � 0 6 SHED o �p DRAIN 28,3' I I 4 , p j o CONC.RE , 6 FF�q. /� o ` ' w STONE DRIVEWAY WALL 18 0 i o 1i 1.3' , 14 , O TIMBER CURB PLAN w STONE DRNEWAV TIMBER CURB - �, NORT Li GATE STONEDRNEWAY GATE p00R �'' OODIBRICK �q�K ,I w J 0�5 v, SHOWER 132f � n WOOD FLOATINGWAL STK. 4'WOOD RAIL FENCE ` STEPS = L.P.GAS � .�' 13,1, 13�� � W Op ALK RAMP v� b'x20' CD 0 FLOATING n oaf GATE WOOD DOCK POOL 0 Qw �qtF EQUIPMENT p ��� a 1 STY FRAME DECK 55 W p GATE DWELLING OCR FFL 20.1 p C_CP .P. 1 4 , W 2; C.P. Co t n O o- Lj CO No CESSPOOL&WELL + DWECK OOD z LOCATIONS PROVIDED 1�•5' c c D o BY PRECISION MARK-OUTS INC. I , 0 ?- —' p O g o 0 12/30/16 �q�CN SPA ` = 0 w o z z J ' 6 Q =C3� CY_ m w , IW = 0 `- LL' Q 1 12 Ja2' 10 z � � � Q 1 t4 ,� 18 16 o L.P.GAScli N b 46'00" E 5.3'N 4'WOOD RAIL FENCE OLU STK. 77,72 STK, 32.51" STK. STK. a 8'N STK. 1.3'N r �\ ��. m O o „ STK. 590 00' STK. STK, STK. ; � Q D S 67 46 00 W MAP OF EAST CREEK ESTATES #12120 DER ARC, -EXISTING HOUSE TO BE RENOVATED/MODIFIED IN EXIST;FOOT PRIM+SHELL ��,�� P�MEE Lpp��'S'/J�� LAND OF DAVID RURBARA HAZARD -NO MAJOR CHANGE TO EXTERIOR-REPLACEMENT OF EISTING SLIDING GLASS BASEMENT DOOR-SOME REPAIR TO EXISTING EXTRIOR STAIR+WALKWAYS- , 14' INSTALLATION OF EXHAUST FANS ON ROOF, -DEMOLMON OF EXISTING BUILT OUT BASEMEN -CONSTRUCTION OF NEW BUILT OUT BASEMENT CONFIGURTION N z k WITH NEW CODE COMPLIANT STAIRCASE TO FIRST FLOOR 04329 -RECONFIGURASTION OF EXISTING MECHANICAL SYSTEMS -MINOR EXISTING KITCHEN RECONFIGURATION �� seal -DEMOLITION OF SECOND FLOOR/MEZZANINE/ATTIC SPACE'0 BECOME LEGAL STORAGE \� P A T- 100 0 U C) N � S U 0 0 J Vow pf Q Q � w LLJ N a � � v w " 00 .. e ..._..- W o � U in ' � z CRAWL SPACE N N O 0 REMOVE EXISTING TREE STUM P ---� BEDROOM 3 EXISTING WOOD 0 REMOVE EXISTING 12"H RAILROAD TIE STEP , U n --- --� ,r - - - � W REMOVE EXISTING FAILING CONIC SLAB+ � DRAIN GRATE cn a w "D Q ' m �0 r- REMOVE EXISTING FRAMING ri I +EXISTING ELECTRICAL SUB PANEL I REMOVE SLIDING DOOR+ CLST �I '1 I PORTION OF FRAMED WALLS _ CLST u _ HALL 2 it ' EXISTING WOOD p REMOVE EXISTING -_ AREA OF FLOOR+ROOF 11 I EXISTING OPEN REC ROOM BATH 2 ° TO INSTALL NEW BATH EXHAUST u EXISTING TILE III BEDROOM 2 EXISTING WOOD REMOVE ALL EXISTING UNUSED MECHANICAL EQUIP TYP. BEDROOM I 0\I CRAWL SPACE EXISTING WOOD REMOVE EXISTING SINK,CAB,MIRROR+TILE FLOOR w IFII1i I--lI+III'ii\I I-i/i-IfIiiI�IICI L L-IFI--__-----II__-----II+Ii+�''I-_------_-----.'-���-fl lIIjI,'/1IiIIii 1iI'/'�n�,i❑I'oIZ_J IIiIIIIi''III IIII II;I_v,-_TiIIlIIIIiI'I''II IIIi I;1 0 III-;III' ---_-----_---- - r+m rr .._-. I ❑- - � - - _I II IrI�I I I I II,_ ��►i II I IIII II II -- ❑------------ r�E- 21 mczc—�Q�O(o AREA OF SLAB i 4- -IT:BE REMOVED HALL 1 k�_1_ iL LIJ 1 _1 1EXISTING WOOD 1I , 4 41- 4 1-I+ }-I-IEXISTING MECHANICAL EQUIP iIII i iiREMOVETO REMAIN Luu� iuli �iLu -- -------- n T� I I+--------- EXISTING CST CABNET T-n II1r HARDWARE �V R- r 11+ EL O�E EXISTING BATHREM Lu WALLS,SHOWER, �\5 CD NREMOVE PORTION)OF SLAB ENCLOFREfif*SH $ --------------r N FOR NEW SUMP/PUMP OFIXTURES --_____________. L------ --_-REMOVE EXISTING ::1 APPLIANCESREMOVE PORTION Of EMOVE EXISTIN' GUPPER+BASE CABINETS I AS REQUIRED FOR KITCHEN N REA OF FLOOR+ROOTDNG RM, REMOVE ALL FLOOR FINISH TOSLAB TY,, UPDATES SEE SHT A600 EXISTING WOOD 0 INSTALL NEW KITCHEN EXHA�S� ONG BATH REMOVE EXISTING KITCHEN REMOVE EXISTING SINK+FAUCET EXISTING WOOD EXISTING DECK HVAC DUCT WORK --------- EXISTING WOOD, _ // o REMOVE EXISTING ROLLER SHADE Lu r-7 _ --- ------- REMOVE EASING COUNTERTOP L--- - - - - -- --- -- REMOVE CD EXISTING REMOVE ALL BUILT IN BEDS o+CLOSETSEXISTI G<AUND - RAC AS REQUIRED TO BE LREMOVE EXISTING NDRY �---- REMOVE EXISTING EGA� TORAGE i r STAIR WALLS+CAETS WALLS FINISHES,FI FIX] ,------ REMOVE EXISTINGAPPLIANCES oBASE AS REQUIRED FOR NEW CLOSET � MFPLAN NORT- - p q Ip' TRUE NORTH SR/0JIzU� JnE NOR� T H +STRUCTURE EXISTING STAIR REMOVE PORTICJOF FLOOR+STRUCTURE AS REQUIRED FOR NEW CODECCMPLIANT STAIRCASE LIVING RM. -REMOVE EXISTING RAISED CONIC, ----- EXISTING WOOD `_____ EXISTING WOOD-- U ENTRY/SITTING RM. XISTNGSTOMGE ;o --- -- -- CRAWLSPACE REMOVE ALL FLOOR FINISH _ _ ___ W �- �' TO SLABTYP, EXISG MECH/STORAGE --------- - ----- W REMOVE ALL EXISTING UNUSED EXIST NG MECH AL EQUIP C�MECHANICAL EQUIP TYP.TOREMAIN W Lo w CVD EXISTING EP TO REMAIN O= ow 10 <� = � a, o W0 LLB O " w FQ EX AC EISTING H TTUB U EQUIP, EXT'HVAC EXT'G HVAC EUIP, EQUIP, SLAB ON GRADE SUN RM. o EXISTING WOOD a5 SE L N04329� N S e L al BASEMENT DEMOLITION PLAN 2 FIRST FLOOR DEMOLITION PLAN 2 SECOND FLOOR DEMOLITION PLAN D- 1 00 SCALE: 1/4 = 1 0 SCALE: 1/4 - 1 0 SCALE: 1/4 1 0 EXISTING EXTERIOR WALLS THE CONTRACTOR IS TO VERIFY ALL MEASUREMENTS IN FIELD+ANY - --••--•. o EXISTING SUB FLOOR+FINISH FLOOR DISCREPANCIES ARE TO BE BROUGHT TO THE ARCHITECT/TEAM PRIOR TO CONSTRUCTIONS. 1 ^ Lu 10' } I --- l ALL CONCRETE 3,500 PSI AFTER 28 DAYS MIN, , ' I F--- z r, NEW PTD WOOD STAIR 1 U z `N EXISTING 2X8 FLOOR JOISTS ALL REBAR ASTM A-615 GRADE 60 13 RISERS @ 7,375"±-12 TREADS @ 10" �, �_ o , (COMPLIES W/2015 IRC R311.75) G�, 1 = o w I FOOTINGS ARE TO BE ON UNDISTURBED VIRGIN SOIL. c) m cV EXIST = REPLACE'ALL EXISTING BATT INSULATION \ Q I / � - ALL SNAP OFF FORM TIES ARE TO BE REMOVED AND REMAINING OPENINGS ARE TO BE --' IV Q ------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - �i 6'STEP (R30) SEALED/GROUTED I W Q 1 NEW 1/2'MOISTURE RESISTANT GYP.BOARD O Q LL -- co 1__ . _ N I I I I NEW 31/2'BATT INSULATION(R13) " BACK FILL ALONG FOUNDATION WALLS IS TO BE CLEAN MATERIAL+IS TO MECHANICALLY COMPACTED IN 6"LIFTS TO 95%OF MAX DRY DENSITY p _ � o - - REPAIR/REPLACE EXISTING BRICK 6" NEW 2"BOARD INSULATION(R12,4) N (2 2X8 H A R j N I I I I LANDINGS AND bXb �- FOLLOW COLD WEATHER CONCRETE TREATMENT RELATIVE TO ADD MIXTURES IN ACCORDANCE WITH II _ _ - -- -- - Qcli CRAWL SPACE AS REQUIRED WALLS I_ NEW - �_-- I I I EXISTING 8'SOLID FILLED BLOCK WALL ACI 212,3R USE AIR ENTRAINING AD MIXTURES PER ASTM C260,AASHTO M 154 OR WATER REDUCING+ SET-CONTROLLING ADMIXTURES PER ASTM C494,AASHTO M 194 ONLY,D NOT E co 0 0 USE CALCIUM HAND IU•TOM WOOD I I I I _ I I I I I 'IL!�PTD WOOD I I I III it I I I EXIST = �= CHLORIDE OR OTHER CORROSIVE TYPE ADMIXTURES �! f STJ(CK BALUSTERS 6"STEP w - C> it ( O LIES W/2015 RC R311.7,8) o = z_ I U NEW CONC RAT SLAB EXIST z - x --� OVER EXISTING DIRT i 6"STEP J II �I' X Lu J RIEPAIR EXISTING 12"STEP = I' STRUCTURAL DETAILS PROVIDED BY. I O i I I CRAWL SPACE I I o - Vyl/2 NEW b"H STEPS z = JOSEPH FISCHETTI,PE00 I I I I z +I _ NEW (2)7,25 LVL FLU . T MATCH EXISTING TIMBER - _ ( }; I w I I i I I �„ o NE I NEW CONC.SLAB w AD SOUTHOLD�NY lO 9771 NEW 725 LVL(FLUSH) - - - - - o 6'STEP I I EXISTING LOCATION _ TERED -- o `_ FOR EXISTING DEFLEC I N w I I 2 Sim I 6 EW DRAIN CONNECTED = TYPICAL FOUNDATION NOTES r TO EXISTING DRYWELL A100 I i A100 f= i p - - — - — L------------------- - -------------- -------- ----- ------ -------- ---- � Q LL ' --- - NEW / MOISTURE RESISTANT GYP BOARD - - o I - I M _ _ _ - - - - - I I - I ' ' 1 VI _ - NEWANDERSONIMPACT I - REMOVE PORTION OF " " " 'RATEDSLIDINGDOOR _ EXISTING SLAB AS REQUIREDA100 ' 8-7" 5'b 7' 0 1 5 IN EXISTING MASONRY OPENING OMPACT SOIL+REPLACE SLAB o _ _ _,I I#FWGD70611 - AFTER FOOTING+WALL IN INSTALLED I I- - - - - - - - - - - - - - - NEW SLAB ON GRADE ' — — LSCZ I , I NEW12'H20 I NE 12'H20 I I - - - - - - - - - - - I I +, a w , TRINGERHANGER o ' INFILL+SEAL UP ALL EXISTING OPENINGS I ' BASEBOARD - - -. - BASEBOARD I I - _ _ _ _- _ _ _ _ _ _ _ _ - _ _ - - _ _ _ _ - - _ +, i i o z I, - I I +� z NEVV(2)7.25 LVL(FLUSH) X I I 12"± � LL I TO CRAWL SPACE INSTALL WOOD ACCESS i i - REC ROOM , I EXISTING SLAB ' ' - I I X8"FOOTING I i DOOR IF REQUIRED TYP. I I o Vinyl J I EXISTING 16" 8"POURED CONC.WALL , y Floor I I NEW PTD WOOD STAIR NEW - 2 13 RISERS @ 7,375"± 12 TREADS @ 10" I DRAIN UNDISTURBED EXISTING SOIL - NEW 4" SLAB ON GRADE - I I A100 -- 1 I (COMPLIES W/ ce �0si TO REMAIN INTACT I n N 3�( of I XISTI G SLAB- i . I I I - - _ G . G � POURED CONC,FOOTING G / KEY ,4 Y i I CRAWL SPACE I I, - { I I 1' X (3)#4 CONTINUOUS N W 2X NEW 4"COLUMN r_�._, I W/24"X24"X8 FOOTING + I I STING SOIL TO REMAIN UNDISTURBED 1 I - -- - - - -REINFORCEDW/ .- I (4)#5 EACHWAY 3"FROM - ' - _ --_ - _ - _ ---- -_-- - - r I WHERE POSSIBLE+PACKED SOLID EXISTING URBED o b —---—� - BOTTOM OF FOOTING - - -- - _ - -- -- -- -- - -- -_- ,r. _ ' I AREA OF BASEMENT 7 A100 - - ` 3 `� TO BE LOWERED ' I A10o c� I ' Aloo SIM 3' 11' S'3" 2 EXTERIOR WALL SECTION @ PROPOSED DROPPED SLAB 3 SECTION DTL" @ PROPOSED DROPPED + EXST SLAB 5 SECTION DTL" @ PROPOSED DROPPED + EXST SLAB SCALE;3/4"= 1'0" SCALE.3/4"= 1'0" SCALE;3/4"= 1'0" I _.. � I ------- --- - --—————— -- - - ---- _ _2" — 3 I I I I __—_-- — I—EXISTING COLI�MN.s - -: } I I I ' I+FOOTIING - - - - - - - - Q - -. ;' I NEW 2'H2O I _-_- EXISTING I _ - - ' r---------- ' HVAC � -' I . . �. . . .,.` - �_. I BASEBOARD a --- EQUIP `_' a - EXISTING FIRST FLOOR TO REMAIN — — — —.— Lu ' ----------- --------1 I SEWER _� $ITBU I EJ TOR PUMP CLST -Vinyl Flo D06 1�VC , i o o EXISTING T NEW(2)7.25 LVL BOX BEAM EXISTING 2X8 FLOOR JOISTS EXISTING 2X8 FLOOR JOISTS SEPTIC 1 1 5 A602 1 A I D05 yl Flo I f , r, I I Il,i 1 'a' °; f 1 ' 'I I f'I r� I 7 I i 1 1 I —1, N"^• - I I � 1 I I f 1 1 1 1 �01 I 1 'j i' �' 1 i I 1 I i'i i 1 i• I N i 1 ll 1 l 1 i j' 1 1 ll I 1 j 1 ,---- '1 I 1 l 1 1�' I 1 1 I „1 1 1 1 I � I � _ I j _ 11 I i 1 I I 1 1''J � I I 11 ��l I 1 � � ' 1 I l r11l- 1 1 liii 'li 1 I' 11 � �.'; J J „ I 4 i I I) j l I •,.1� 1 Dol 12'lt'1 HALL R - - - - - -- -- - - 5 3 VI Floor' $ E3 u I o Tie M E ST NG 4"COLUMN `' 1 r _1_ I I - I - +FOOTING - 1 o = DOb �� D04 D03 '— NEW PTD WOCD STAIR W/WOOD HANDRAIL+ I I I O z = _ - D02 I _Q03 c� c� z - 1, z PTD WOOD STOCK BALUSTERS - - II - I i = � _ +I +I I1J 13 RISERS @ 7.375"±-12 TREADS @ 10" AIR HALL . _ !, i' CD 1 c� x - - - -(COMPLIESW, =. I tiny! ku /D YIER w ; z z oo - - "' z �- r n�ti�51 ' ' tt11 PTD GYP +, z - J a " w o - - - - - - - - - ----- -- -- - - — — — 1 — — t U� S I � 00 Z ^ U w w ——————— i��.- - t o 0 0 0 >�_ EW 4 1 0 III h---- ---- TII I z i--------------- _ - ! I; /D YIER 3 II , pp } q t ^ U 1C� - ___I _ _ _ _ ____r _ ,r rl PANTY I I I _R I I I o I I' I I o I I , I I - _ I I I I- _ I I NEW 4 COLUMN �' - +I — -= TI [L-1 '� _ == -I i I I DRANK NEW - - - — - - - - —'' ----- - - - -Vln I Floor' IWJ 24 X24"X12 FOOTING I 1 I - - (I I -�1E�OLWOOD�IAIQS_ d L -- M I I I - REINF REINFORCED W OC I - / - II I (4)#5 EACHWAY 3"FROM -- - - - - - - �, FRIG DRY N LAUNDRY PLAN BOTTOM OF FOOTING i i N CLOSET Vinyl Floor =__-_,' i I l I I NORT TRUE I - NORTH I _ EXISTING SLAB EXISTING FIOUNDATION WALL CRAWL SPACE 3' " 3'2"± +� 11'8"± I ? ; _..-SEE DETAIL 2 ZJ_ SEE DETAIL 3 +FOOTING It Iv THIS SHEET SIM W LOWERED SLAB OOD S THIS SHEET-Sim NE NEW W TAIRS ' I INFILL+SEAL UP ALL EXISTING OPENINGS INTO CRAWL SPACE-INSTALL WOOD ACCESS DOOR IF REQUIRED TYP. i A I,a ,1u II u I I I I 100 a uI u u 1 I I I I-- - I _I BASEMENT SECTION NORTH/SOUTH RECROOM ( VESTIBULE I HALL I LAUNDRY STORAGE I I L___ ' SCALE;3/8"= 1'0' I ' I MECHANICAUSTORGE ; U PTD.CONC, D07 1 I I I I • EXISTING FIRST FLOOR TO REMAIN Z + EXIS ING BOIL I ' W z EXISTING STORAGE � I I HOLDING T K ELECTRICAL PANEL PTD. ONC. I = I EXISTING 2X8 FL JOISTS NEW ANDERSON IMPACT RATED SLIDING DOOR W LO z ' I I �� I i EXISTING DUC K MASONRY OPENING z � `--------------------- ---------------- -------- - ------- --- ------- ------, ' FWGD7061 / _-.. EXISTING(3)2X8 E M _ 0 "- w yL_ ( >— � p --------------------- -----------i i----------------------- -----------------I I C!� Z z z 1 6 ='^ m w 0 0 A100 = - --.._ - - V Lv Q U U CRF WL I k' 1 j I ;p - - I" I W = O E i-u 1 I I I INFILL+SEAL UP ALL EXISTING OPENINGS SPACE II @ I I I I l I L•t- = c w cn I I I I it I I I I � I III I ; 4 I I Ln INTO CRAWL SPACE INSTALL WOOD ACCESS I k I NEW IFFIT ♦ U o O I: REMOVABLE ACCESS I I I DOOR IF REQUIRED TYP, II; DOOR I' li I, o m U s I ; 6 . f I k I 6 I I II F_ I 1 U I I I ' k k 1 g ; I II I II ill I I i I I I.s I I I CD , II z ti , I_I_I I' I I I I Q II li I SLAB ON GRADE I I I I kI w w I y ! J , I _ I I I I I I w I' <� I C9 I O a y I I I i i ., I I - S III I I ,I I I S ^ z I II II I - � 1 J J I I I I I 1'gg I a �r E I I I a � r— I R �M E D Ape P\ EE Lo I I ' x Rm L----------------------------------- I . I ' r----------------- ---- ------------ ------- T 04329 SEE DETAIL 2 NEW LOWERED SLAB NEW 4'COLUMN W/24"X24"X8 FOOTING SEE DETAIL 2 ^ _?C F �� THIS SHEET-SIM REINFORCED W/(4)#5 EACHWAY 3" THIS SHEET-SIM Seal FROM BOTTOM OF FOOTING I/V BASEMENT CONSTRUCTION PLAN i BASEMENT SECTION NORTH SOUTH - RECROOM A-100 SCALE;3"= 1'0" 7 SCALE:3/8"= 1'0" 0 U Q � U L1/ N r I I V z c Z� N 0 0 I 2 w Q N Q �W - — — — — — — — — — — — — — — — — — — — — — — — — — — — — . ¢_ Q I I 0 - ------------------------ 1 J n -0 I I W J Q E w I I G_ EXT'G t EXT'G Q co N 1ST FL00:- 1ST FLOOR SUPPLY 1 I SUPPLY I I I I I 1 I I I I I I I I I I I I I O E i ..................................I � � MECHANICAL NOTES � 0 ALL EXISTING HEATING AND AIR CONDITIONING SYSTEMS TO STAY IN PLACE+ARE TO BE w I MODIFIED OR EXTENDED FOR NEW BASEMENT LAYOUT,IF CHANGES ARE REQUIRED/MADE DURING w CONSTRUCTION TO ANY EQUIPMENT-ARCHIECT/DESIGNER WILL PROVIDE REQUIRED INFORMATION w 1 I AND FILING TO THE BUILDING DEPARTMENT AS PER CODE. LJJ Q -------- ---------- -- ----------------- --- - ---- -----NE19L(2)Z2il�lLBQXJ3E6M ---- -- - — — — — — t........................................................ ............. - r ' 1 0 r------------------a - ----------- -- ---- ------ - EXT'G ' _ ST FLOOR 1 1ST FLOOR i i 1 SUPPLY I ' I 0 1 1 I ' CELLAR P c m CELLAR SUPPLY I I I 1 I I X I � I ' 1 1 EXIST PLUMBING WASTE LINES TO BE I i EXISTING DECK FRAMING — 1 "OWL HEIGHT To REMAIN As Is L....... NAILING SCHEDULE � 1 r I _ I ROOF/CEILING FRAMING COMMON EXISTING 2 x 8 FLOOR JOISTS—►i I E i I EXT'G i JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING I 1 ST FLOOR I RAFTER TO TOP PLATE(f0E-NAILED 3-8d PER RAFTER C?L �`J� CEILING JOIST TO TOP PLATE(TOE-NAILED 3-8d PER JOIST CEILING JOIST TO PARALLEL RAFTER(FACE-NAILED) 4-16d PER LAP NJL I CEILING JOIST LAPS OVER PARTITIONS(FACE-NAILED 4-16d PER LAP 1 i ' ©N'i i COLLAR TIE TO RAFTER(FACE-NAILED) 3-8d PER TIE - BLOCKING TO RAFTER(TOE-NAILED) 3-8d EACH END IT ' ' I I RIM BOARD TO RAFTER(END-NAILED) 2-16d EACH END .................. ........ ................................. '' EXIST PLUMB,NG AST LINES TO BE - — — - - - - -_- -- --- -- --REWORKED FOR MAX LNG HEIGHT i WALL FRAMING I I - ------------------ ---- --'-i JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING r 1 - - -------------- ___• I ' ' ' TOP PLATE TO TOP PLATE(FACE NAILED) 2-16d(1 PER FOOT 1 I 1 TOP PLATES AT INTERSECTION(FACE NAILED 4-16d JOISTS-EACH SIDE �XT,:� STUD TO STUD(FACE NAILED) 2 16d 12"O,C, ' 51 �i i -I'� EXISTING 2 x 8 FLOOR JOISTS 1 I ' SUP. LY I ' ' - - - - - - 1 HEADER TO HEADER(FACE NAILED) 16d 16"O.C.ALONG EDGES ' ------------- «i-- EXIST R T I--I- - _ _____ ------_------ i EXT'G TOP OR BOTTOM PLATE TO STUD(END NAILED) 2 16d 1 PER STUD TO PLATE,10"WALL HEIGHT MAX 1ST FLOOR BOTTOM PLATES TO FLOOR JOISTS,BANDJOIST 2-16d(1,2) PER FOOT ' L-J J FAN RUST- I SUPPLY ENDJOIST,OR BLOCKING(FACE NAILED) 3-16d AT BRACED WALL PANEL --------------------1 1 - i I - FLOOR FRAMING ¢ - ' JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING o EXISTING 2 x 8 FLOOR JOISTS I I JOIST TO SILL,TOP PLATE OR GIRDER(TOE NAILED) 4 Sd PER JOIST 1 I BRIDGING AND/OR BLOCKING TO JOIST(TOE-NAILED) 2-8d EACH END JEVI'J;✓O IFIED;HVAC 7U114"LIN ____ ' ' BLOCKING TO JOIST(TOE-NAILED) 2-8d EACH END BLOCKING TO SILL OR TOP PLATE(TOE NAILED) 3-16d EACH BLOCK LEDGER STRIP TO BEAM(FACE-NAILED) 3-16d EACH JOIST TING_ DEFLECTION I I JOIST ON LEDGER TO BEAM(TOE NAILED) 3 8d PER JOIST I I BAND RIM JOIST TO JOIST(END-NAILED) 3 16d PERJOIST I II 1 I BAND RIM JOIST TO SILL OR TOP PLATE(TOE-NAILED) 2-16d(1) PER JOIST 1 I I I ROOF SHEATHING I j 1 I JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING STRUCTURAL PANELS 3/4'CSX PLYWOOD 10d 3"EDGE/6"FIELD IIJSH I I DIAGONAL BOARD SHEATHIMNG 1"X6"OR 178" 2-8d PER SUPPORT 1 -- 1 I DIAGONAL BOARD SHEATHING 1"X10"OR WIDER 3-8d PER SUPPORT NEW(1)7.25'LVL LUS )SIST ED ! XISTING _ _ J I CEILING SHEATHING I I I ' JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING Q � 1 1 _ i I r. ----------------------L ' (2)7.25 LVL(FL I GYPSUM WALL BOARD 5d COOLERS(3) 7"EDGE/10"FIELD o -- I I WALL SHEATHING c� ¢ ' JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING z w DRYER VENTS o I m - T IN EXISTING LOCATION STRUCTURAL PANELS 5/8"CDX PLYWOOD 10d 4"EDGE/8°FIELD 1 1 J ! �, I GYPSUM WALL BOARD 5d COOLERS(3) 7"EDGE 10"FIELD o I I - ER _ I I DIAGONAL BOARD SHEATHIMNG 1"X6"OR 178" 2-8d PER SUPPORT I I - ! I �'! FXT'G DIAGONAL BOARD SHEATHING 1"X10"OR WIDER 3-8d PER SUPPORT o 1 11 H_OOR IST FLOOR ' I ' V UPPLY FLOOR SHEATHING 0 I .KT'G o I! JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING I ,1 STRUCTURAL PANELS 3/4"CSX PLYWOOD 8d 6"EDGE/12"FIELD ST'L R I 0 I Nl N i STRUCTURAL PANELS GREATER THAN 1" 10d 6"EDGE/12"FIELD 1 I 1 0 ' ^ ^ I PLAN DIAGONAL BOARD SHEATHIMNG I"X6"OR 178" 2-8d PER SUPPORT TRUE j DIAGONAL BOARD SHEATHING 1710"OR WIDER 3-8d PER SUPPORT NORT !� ,.,., Lu NEW EXHAUST ' EXISTING DECK FRAMING ;: NORTH c TO REMAIN AS IS o ; ; N it ; TYP. FRAMING NOTES I o 1 I o (2)7.25 VL ' -- ' o t XT'G AL LUMBER IS TO BE N0,2 OR BETTER DOUGLAS FIR LARCH(N)WITH THE FOLLOWING z i i �: IST FLOOR MIN SPECIFICATIONS 1 N r x I °'UPPLY ' XT'G 1 ' E "' E) 'G(3) X8 B M(L W) ' Fb=825 PSI I ! ST FL ," i i - - ' i Fv=95 PSI V J I I Fc perp=625 PSI Q 1 1 w 1 I E= 1,600,000 PSI Z --EXISTING 2 x 8 FLOOR JOISTS ► i ALL PARALLAM(PSL)LUMBER TO HAVE THE FOLLOWING MIN SPECIFICATIONS Q = I � 1 i Fb=2,900 PSI V) w EL PA =L = 90P Lii L - ------� I w + Fv 2 PSI --- ---------------- 1 � Fc perp=760 PSI Z Q - I E=2,000,000 PSI U' z_ ------------------------------ 0 I- �----------------------'----------- � . ----------- ALL 1 EXT'G I 7 U1 z Q I I 1ST FLOOR I ; I Fb=2,600 PSI = w Lam`' ''^^ m SUPPLY i I i Fv=285 PSI V O I I I Fc perp=750 PSI Q E= 1,900,000 PSI 1 EXISTING DECK FRAMING ALL PRESSURE TREATED LUMBER IS TO BE MCQ N0.2 OR BETTER YELLOW SOUTHERN PINE ♦ a�_ TO REMAIN AS IS Z r— 1 I I i i Fb=975 PSI Fv=90 PSI Z Fc perp=660 PSI C EXISTING SLAB ON GRADE ' 6 I I E= 1,700,000 PSI - I 1 i ALL TJI'S IS TO BE 230 Q o ..................................................................... ALL BEAMS FABRICATES WITH MULTIPLE LAMINATED VENEER LUMBER BOARDS ARE TO - I BE NAIILED/BOLTED AS PER MANUFACTURER'S SPECIFICATIONS _ _� ALL STRAPS,CONNECTORS,PLATES,BOLTS,NAILS ETC,ARE TO BE GALVANIZED OR STAINLESS STEEL. � UNLESS OTHER WISE NOTED, C�� P�MEE L�AF`y1�\ I I I 1 ALL DESIGNATED CONNECTORS,STRAPS,ETC TO BE SIMPSON(UNLESS OTHER WISE NOTED)+INSTALLED PER -' 1 MANUFACTURER'S SPECIFICATIONS, * < I ' L-------------------- ------------ ---� ' ALL WALL SHEATHING TO BEI5/32 INCH APA RATED EXPOSURE I PLYWOOD+SHALL BE NAILED WITH 10D COMMON NAILS 6"O,C,EDGES AND 12"O,C,FIELD >' I — — — _ 04 `- -------------------------------------- -� ALL BOLTS NUTS AND WASHERS ARE TO BE HOT DIPPED GALVANIZED UNLESS OTHERWISE NOTED, 0 o �( I I j CONTRACTOR TO INSTALL SIMPSON HURRICANE TIES+STRAPS AS PER LOCAL BUILDING CODE, Seal I I LOOR STRUCTURAL PLAN j 2 STRUCTURAL + MECHANICAL NOTES A-101 An_ l'O" INTERIOR DOOR SCHEDULE DOOR PANEL DOOR DETAILS REMARKS Q N0, TYPE HD%R FINISH MATERIAL QTY. WIDTH HEIGHT THICK. HEAD JAMB SILL PTD WOOD PTD WOOD FLAT - PAINTED WOOD i n FLAT PANEL LOUVER DOOR FLAT PANEL DO1 A Q Paint Wood 1 2'8 6'8 ± 13 4 DTL 3 DTL 3 SIM DTL 4 DOOR U N DOUBLE DOOR ,- w D02 B o Paint Wood 1 2'6" 6'8" ± 13 4" DTL 3 DTL 3 SIM DTL 4 o I j D03 A un Paint Wood 1 21' 6'8" ± 13 4" DTL 3 DTL 3 SIM DTL 4 o-- = o w I - D04 A Wood Wood 1 2'8" 6,8" 13 4' DTL 5 DTL 5 SIM DTL 4 SIM Q I D05 C Wood Wood 2 2 1 10 6 8 13 4 DTL 3 DTL 3 SIM DTL 4 PTD WOOD - PTD WOOD —PTD WOOD N Q FRAME FRAME FRAME W LL' - - - - - - -- - - - - - - - - - - D06 A Wood Wood 1 2'6 6 8 13 4 DTL 3 DTL 3 SIM DTL 4 a. w i 1 D07 A Paint Wood 1 2'8" 6'8" ± 13 4" DTL 3 DTL 3 SIM DTL 4 TYPE A TYPE B O z co I TYPE C w o EXISTING 0 00 04IR Lu INTERIOR DOOR SCHEDULE + ELEVATIONS N I SCALE: l/4"= 1'0" Q � LINE OF EXISTING STRUCTURE LINE OF EXISTING STRUCTURE 1 I U BEDROOM 3 i �� SOLID PAINTED WOOD PANEL NEW GYP GEILING+FRAMING % LOUVER DOOR MAY OCCUR. ,- I EXISTING WOOD � ' � / SEE DOOR TYPE NEW GYP GEILING+FRAMING w O I ( CASING OR FRAMED OPENING MAY BLOCKING AS REQ, Q HEADER AS REQUIRED I II I � � � � q � OCCUR BEYOND 3/q� � o TILE ON THINSET MAY OCCUR - �171 POCKET DOOR 0 HARDWARE o GYP BD.TYP,MRGWB AT TILED WALLS ' �' o _ '' PAINT INTERIOR ,- j CEMENT BD AT SHOWERS VINYL FLOOR ON EXISTING SLAB �„ POCKET BLACK W w j F PTD CONIC.MAY OCCUR I (EX)H20 (EX)H20 � � I B.O.F.O.HEAD / N BASEBOARD BASEBOARD i L / 6'8"A.F.F, / --- ------ _-B4O.RO.HEAD_____ w o j I STEP -- - - - - - - Cl> - 6'8"A.F.F. p `` SOLID PAINTED OR ^ o' - - - _----- ---- (EX)H20 " ' , PTD,WOOD TRIM '�% ( WOOD FLAT PANEL Lv z (EX)H20 CI$T I I --------- PTD,WOOD TRIM l / POCKET DOOR BASEBOARD l BASEBOARD I I .� PTD DOOR STOP AT PTD DOORS OD PANEL INSTAL NEW EXHAUST CLST I I - // LOUVER DOOR MSOLID PAINTED OAYY OCCUR, FAN TO ROOHALL 2 SEE DOOR TYPE / EXISTING WOOD l — EXISTING TILE BEDROOM 2 ---- -- 3 TYPICAL DOOR HEAD DETAIL 4 TYPICAL OOR SILL DETAIL POCKET DOOR HEAD DETAIL — EXISTIN WOOD _ SCALE:3- 1 0 SCALE:3 = 11011 5 SCALE:3"= 1'0" I n n BEDROOM 1 /0 I — - -- 1 1/2 3/8 EXISTING WOOD � SHIM AS REQ I I M NEW VANITY ------ - - -- - _ � z PTD.WOOD TRIM PTD,WOOD TRIM ui o I HALL 1 EXISTING WOOD NEW FLOOR TILE REPLACE, - CLST EXISTINGBATH 1 ------- KITCHEN - j HARDWARE___ TO MATCH - - -- --- - (EX)H20 BASEBOARD i SOLID PAINTED OR WOOD --- --- — — - - --------- -----. - _ = - - - - - _ .fie-..= � --- --- ----------- 1/2n 3/On w cll 1 O SINGLE PANEL � N —_--_____--__. Q II i POCKET DOOR o CD !I _- u _-- ` REPAIR EXISTING WOOD FLOOR ____.___-_..-_____ _._ PTD,WOOD TRIM I _ CD - ---! _ EXISTING DECK GYP BD, NEW 36" DINING RM. EXISTING-WOOD h; INDUCTION nO�l/E REPAIR EXISTING BRICK I I if RANGE EXISTING WOOD - POCKET T DOOR JAMB DETAIL .. i WALKWAY TO BE LEVEL ( y -- ---------- - 6 EXI3TINGHIENN � SCALE:3°= 1'0° EXISTING WINDOW OD ! I 'T' - MATCH EXISTING REPAIR CRANK MECHANISM )I NEW �' SADDLE TO EXISTING SINK FLOOR STAIN "T NEW H2O = _ _ -------- ------------ NEW 36"FRIG - II !„ BASEBOARD - , NEW MILLWORK jf;', 11 6 III I - CLOSET _ 1 y �'I (_I: I ------ - ---- - 0 0 - - r NEW PTD WOOD STAIR W/WOOD HANDRAIL+ ! PLAN PTD WOOD STOCK BALUSTERS --- ----- -- TRUE NORT N to l 13 RISERS Q 7,375"±-12 TREADS Q 10' NORTH (COMPLIES W/f@1R�f2SI n�j�` ---------- _ �0 0 U N RM c�R- I --- ----- --- EXISTING WOOD ENTRY/SITTING RM. - - e I — IJ EXISTING WOOD D I \ _ I I A100 MATCH EXISTING _ - , U SADDLE TO EXISTING Z z FLOOR STAIN I -- - ---- W ------- (EX)H20 z BASEBOARDcn (EX)H20 - - --- -- I W O BASEBOARD - -------- ---- ----- w U� - - - - - - - - - - - - - - - - -- ----- - -.�. O � zo - -- I � � z Oz --- - - - --- 0 w U O F__I I - - - ---- (D c� � Q � � 0� (EX)ELEC UP I --- / BASEBOARD / W _� O ,- z EXT'G HVAC i -- -- .- - / + o �OU (Ex)ELEc Q Q EXISTING HOT TUB d- � BASEBOARD ---- EQUIP, -- ---- Z EXT'G HVAC EXT'G HVAC ;'I -- - ---"- / U I EQUIP, EQUIP, -- --- z SUN RM. / - - --- - --- / EXISTING WOOD / m FLED q (�\ P�ME -._.... - I 18 lh N 0432 REMOVE WINDOW FILMI RESIDUE OFF / / �0 �y EXTERIOR OF WIf DOW / / Seal FIRST FLOOR CONSTRUCTION PLAN j A- 102 SCALE: 1/4"= 1'0" 0 U z N �.L1 uJ i r Y 0 U O w I m L w I z00 N W O Wco 0 Q I Q N N � I I i ; j I I I EXISTING ROOF TO REMAIN I I I w Iw j I i N 00 I w �, o , ; i II i1 I' NEW BATH EXHAUST - - - --- - - -- -- - - ® NEW EXHAUST ENCLOSE+INSTALL ` BATH' Ii - --- - -- --- -- - , UP TO ROOF ( OPEN TO BEDROOM BELOW - -- - - - - ---- I I I - I �BEDROOIMEZMNEST GE-j EXISTING SKYLIGHT -- _ -- EXISTING WOOD AB vE - - EXISTING ROOF TO REMAIN - - - - EXISTING SKYLIGHT U - - - - - y/ w , I . rr1✓ , �Q ; w - - EXISTINGROOF T 00 0 REMAIN I ENCLOSE+INSTALL - -- --- -- -- ---- I NEW KITCHEN STOVE EXHAUST - - - ---- I UP TO ROOF -- - -- - - - - -- - - -- NEW KITCHEN EXHAUST Lu / I o 0 I - I i EXISTING SKYLIGHT EXISTING SKYLIGHT - - — - - - I II _ (ABOVE (ABOVE I i \� EXISTING ROOF TO REMAIN EXISTING SKYLIGHT EXISTING SKYLIGHT w L_ r � �� I - -- Lu PATCH WALLS+A EQ D I FROM BUILT IN+C SET DEMOLITION onCIO ST �WGO'OEXISTRID v" ` - bfi I -- --- --- ------ - -- - -- - - I - ORTH PLAN NOR T � TRUE I � ABOVE XISTIZ SKYLIGHT [EXSTING SKYLIGHT - - - N OVE I - - -- I, E— E— EXISTING SKYLIGHTEXISTING SKYLIGHT , EXI 11 G S GH - - - EXISTING REMAIN ROOF TOREM --�- , I - -- - - - - -- - -- - W o I - I I I I _ • W z , - - _- - - - - W Lo I , I , I � ; z Q o� o 0 I - - - o I - - -- - W = 0 F- z u- Lo = aOz j - - - - - + d U wQ j i G o EXISTING ROOF TO REMAIN m it I . I �FtED ARC j u EELOA F lc� j 0432 ct I I Seal " m I I SECOND FLOOR CONSTRUCTION PLAN j ROOF PLAN A-103 SCALE: 1/4"= 1'0" 2 SCALE: 1/4"= 1 0" —a Wall Phone I TV Location o -HDMI as Required L-- -- -CAT 5&CAT 6(2 each) -Cable E— z -Power V w TV Box Location o HDMI as Required = w NB -CAT 5&CAT 6(2 each) V I— —.- -Cable Q W' Power Q - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Inferred i n ye � � ----------------------- O.- N ' I Ethernet-2 ports at z co each location LL o FS Siren LU � J , CRAWL SPACE H D Heat DetectorZZ CRAWL SPACE , ""- ' I I I I OS3 J i i i i ® Water Detector I AL(AV) [0--I Audio/Video Alarm Keypad I I I I I AL(A)E-1 Audio Alarm Keypad © Motion Dector V� Volume Control 0 sP Recessed Ceiling Speakers in o I � U OS3 Exterior Recessed o s Ceiling Speakers I 1 L.LJ u Bookcase Speaker r I I m n I 1 1 w Sub-WooferEXISTING EXTERIOR SCONCE Q --- P Recessed WallSpeakerQ `' > I WS u I O r - r - - - - - - - - - - - - - 7 I r------------------ - -- - ---------- ----------- ------ --, I F Z - - __. = -= - - - - - - - - - - - - - - - - - - - - - - - - - 1'. >: I Wall Mounted,Speaker I I 1 I - -`=- - - -__- - - - - - - - - - - - - - - - - - - - - - - - - -- - _: -- - I I I I I I Et Wall Exterior a EsP Mounted Speaker rll I h HT. 7'3,....--...•. , A A A — — _ A _ I , I 1 , SP Planter Speaker - - - - - - - -I•- _ - - _ _ _ - - - . - - 1 NIWI , I I I N --SOPPLY-- Thermostat 4CLNG.HT.-7'11'± I PECIR OM REC ROOM - - - - - - - - - --� - - - - - � - - Pt C-Vp i iKLNG,HTI-8'1"± i I I I -$ I I I I Ptd,Gyp, , Junction Box i I 1 Duplex Outlet ----':- ,III1IIi1 --- I � IF NOTE D TO BE A OF CI A SWITCHED-TOP O UTL ET) Q Outlet l---- CRAWLSPACECRAWL SPACE , Ground FaultGFI Interrupt Outlet Exterior Outlet(waterproof) t erproof)_ � Exterior Recessed LU -- ------ RWP Waterproof Outlet A A - I{ Dedicated Outlet .. -0usB USB Outlet CM ---------- ---- -------------- -- 0 i - - r k,=� '_r - i'' -.•� -aL«II I-,.J,•-.-.IIII II.-. IIII;I�--i• �i----: '--.L,----O�-S l. -I -<----$-O-C-L-N_G-_,-H II1 1ii.ilI','--"+ _-J--S-i-I"-�I-=_--—_--l ,S --,IIII--''~,--,,•1 j-" I_.-- -_•�I I;- '.,•--'II--,- , ._: iIIIIIIIIIIIIIIIII•1 ,Y11IIIi1II�I,I1II. •' 1III,II1IIIIIiIIII1I I-- -IIIIi,'I,III L ij_IS�IijlI -- Duplex Floor loor O„ u t l— e t -a --,- • --------------- - - - Gas Connector Wire Mold w/Power& -.-1 Data - tQ TrnTrrrrrrrTrrrr -a (See Low,Voltage For#Of Outlet s\/ P-',r o vQo-id eEXISTING t------- ----------- _- - - - --- Receptacle Every 12') ------- --------- HVA - OS3 P� BULE Smoke/rCarbonmonoxide Detector ---- -- fl Lu PGyp THXHAIJ PtdA SEWER A Gy EJECTOR PUMP Smoke Detector Tied Into Fire Alarm- - /oN4VZCm~ VESITBULE �oN AYp' C LN� HT. ATH Lutron Home Works Switchy, GFI New Double Pole Switch Jamb Switch CM A A Recessed Ceiling Fixture [SID LII S HALL � Exterior Recessed -'•-•- --- ----- ------ P�d.Gyp, - Ceiling Fixture Surface Mounted OS3 Ceiling Fixture oaOSl WASHER RYER UNIT Pendant Mounted Fixture A r - - - - - - - - - - - -- -- - - - - - - - - CNtZoZ- ZQ�) OS2 i----------- -------- --- INR - - - - WASHER RYER UNIT �CLNG,HT. 7' Ceiling Fan ` PANTRY _ A A o - - - - - - - - , LU L o"'Closet/IMillwork FixtureLAUNDRYPtd,Gyp. Wall Mounted Fixture LAUNDRY Ptd,G�p, Picture /art LightEXHAUSTA / PE P L`A' UVr"N � — D` C, R yO_U-_/Q_ EUP DRY CEANER UNIT NORT Recessed Linear Ceiling Fixture NORI�I IT � ' �IH CRAWL SPACE SPACE Wall Mounted Fixture I ❑ RWL Recessed Wall Light MECHANICAUSTORGE MECHANICAUSTORGE -_ L Fl Path Light ------ ------ GFI L 0'-0" Ceiling Height Above Floor T�� OS3 00S3 Supply Grille® Ljj IIXII_ ' Return Grille . ---------------- EXIS ING BOIL ® Access Panel WA- OS3 STORAGEOS3 EXISTINGHO DING T STORAGE SS Self Switching Fixture CD 0 ELECTRICAL PANEL WL Fixture Centered W U --------------------- � ------------------------ inS ace Qc — /771 )OJ ---- ------------------L------------ --------- ------------------------ yZ Cl� �/ Zw RELOCATED p , I SWTH+OUTLT , EXISTING BASEMENT � SUB PANEL LOCATIONS DIAGRAM ZQ w1 1/2"±TO WIDEST DEVICE W = 0 � •9 Lm LU KEYPAD,PHON + wES& DOOR CASING o -THERMOSTAT _SWITCH. SLAB ON GRADE SLAB ON GRADE -OUTLT-.Horizontal - -0 C?I (May Occur In Base See < ai SEE ELEVATIONS FOR GENERAL o.E LOCATIONS AND SPECIAL EQUIPMENT �M�E LOP RCP FOR EQUIPMENT AT CEILING n L----------------- ------------------ AllLightsShallBeOnDimmers-ElectricianTo Coordinate Demmer Types W/Proper L---------------------- ------------------- Loading&Light Fixture 4329 All Smoke/carbon Monoxide Detectors Shall pF Se ai; L be installed per code BASEMENT REFLECTED CEILING PLAN 2 BASEMENT ELECTRICAL PLAN A-200 1 SCALE: 1/4"= 1 0' SCALE, 1/4 = 10 -Q Wall Phone TV Location o 0 -HDMI as Required Q C) -CAT 5&CAT 6(2 each) w I ' I -Cable F= 27 Q -Power U z ^ V Box cation 0 THDMI as Required = o o TVB -CAT 5&CAT 6(2 each) ag m Q I I -Cable Q w -Power N Q l I -Inferred Eye a- W n 0J — j Ethernet-2 ports at -� z N j each location LW o 7 I Siren z l HD Heat Detector Qcli j I ® Water Detector I I : AL(AV) Audio/Video Alarm Keypad I AL(A) kD-I Audio Alarm Keypad V BEDROOM 3 I I I ' BEDROOM 3 � EXISTING GYP I D Motion Dector NO WORK TO EXISTING I I I NO WORK TO EXISTING LIGHTING OR SWITCHING l I ! ELECTRICAL V Volume Control 0 I I l i j j j sP Recessed Ceiling Speakers o j I j j s Exterior Recessed o Ceiling Speakers Li � sP Bookcase Speaker w I I sw Uj Sub-Woofer LU c o _ I w c, Q T T - WSP Recessed Wall SpeakerCV 0 l CLST ! CLST ;--- ; ' - Wall Mounted.Speaker - i Exterior Wall CLST I I CLST - I ---=J" - \ \ - — — ESP Mounted Speaker I FA A ST HALL 2 I Planter Speaker HALL 2 l EXISTING GYP I ( BA 2 NO WORK TO EXISTING I --- -- O N TO EXIS ELECTRICAL TV BATH 2 I ELECTRICAL -- ----- Thermosilat EXISTING GYP; BEDROOM 2 I I BEDROOM 2 EXISTI G GYP Junction Box I NO WORK t0 EXISTING i COMBINE NE WITCH I _� — N&M 0 EXISTING I , I — —ELE RICAL --- - Duplex Outlet W/EXISTING WI CH BANK i� I i LIGHTING-OR SWITCHING I -I o I'- � (IF NOTED TO BE ��- �� I I I �\� I ---- - ---- -__-- SWITCHED-TOP OUTLET) BEDROOM 1 \ ! j U� I EXISTING GYP BEDROOM 1 ! i ---- Quad Outlet NO WORK TO EXISTING NO WORK TO EXISTING I -- - --- Ground IFault I ELECTRICAL -- GFI LIGHTING OR SWITCHING - ----- - - Interrupt Outlet �WP Exterior Outlet(waterproof) Eml Exterior Recessed ' I --`� ----- --- -- Waterproof Outlet I HALL 1 I o -�- - I NO WORK L EXISTING '" I 'I __ _- _ -0 Dedicated Outlet EXISTING GYP I G -- -------- - -❑USB USB Outlet ELECTRICAL - I I I BATH 1 Q Duplex Floor Outlet CLST -- - — j CLST WORK TO EXISTING Gas Connector =__ ELECTRICAL --- -- - I Wire Mold w/Power&Data _ _ ----- (See Low Voltage For#Of Outlets/Provide iI Receptacle Every 12") - - - - - - -- - - - ----- - - ------ -- M Smok arbonmonoxlde Detector =- - -: g _ D I _ ------------------- e II; _ IIII �_ -_ N UST ( REPLACE_ _- ¢ l I i = - -NEW- _ SD Smoke Detector Tied Into Fire Alarm ij,EXISTING_- ___ tt o l - NEW 36" NEW a. l DINING RM. I !!i; - INDUCTION HOOD= - --- ----- -- - Lutron Home Works Switch _ I - EXISTING GYP I i i ° RANGE - EXISTING DECK------------ ,, 1 - DINING RM. _ �16WORK7aEXi5Tih1G- $ New Double Pole Switch EWGFI NO WORK TO EXISTING ELECTRICAL--- KITCHEN WORK TO EXISTING I KITCHEN -- -- --- - 0 Jamb Switch KffCHEN 'll i PER CODE ELECTRICAL �S EXISTING GYP LIGHTING OR SWITCHING I I ! NO WORK TO EXISTING u - -- Recessed Ceiling Fixture fIaJ {: I ' T Exterior Recessed LIGHTING OR SWITCHING u a ❑— j n --- ---- Ceiling Fixture !,I NEW OUTLETS -- - Surface Mounted z jai!-'� CeilingFi;xture - - I - --- Mounted Fixture I - - - _ - -- Pendant M t ¢ - - - - - -- - - - --- -- _ NEW GFI _ - - - - - I I � 4{I� �ll� - - - - - j -------- - ----- --- --- - - ZD Ceiling Fan ' (REPLACE - - - ---- - -- -- o ——— l - _I EXISTING - - ----- 0 0 _ Wall Mounted fixture N COMBINE NEW - - - j _ _ _ -- - © Closet/MIllwork Fixture "' I • W/EXISTING SWI1K- - - I - - - - I ----- - - - _ -- - - Picture/arf Light PLAN Recessed Linear Ceiling Fixture NORT TRUE NORTHj - - - - - - - i - - - I -- Wall Mounted Fixture _ _ - ----- WING RM. j RWL WING RM. I ENTRY/SITTING RM. - - _ EXISTING GYP j � I EMRY/SITTING RM. - - - - -a I NO WORK TO EXISTING ___ -__ Recessed wall Light I EXISTING GYP NO WORK TO EXISTING - ELECTRICAL __ NO WORK TO EXISTING NO WORK TO EXISTING LIGHTING OR SWITCHING j I ELECTRICAL 6PL Path Light j LIGHTING OR SWITCHING " ' ------ 0'-0° Ceiling Height Above Floor I -- -- -- ® Supply Grille W Return Grille j I j ---- --- - -- ® Access Panel W 0 z SS Self Switching Fixture =, I - --- - --- Cn - - - - -- I _ W � U f- Fixture Centered Lv w � U z r- w v -- 1 - --- ---- ----- Cn Lv z z _, j -------- m wLU -- ---------__-.__ SWITCH+OUTLET n- _..- ---------------- LOCATIONS DIAGRAM Q O0 U j I I j -- -------- 1 1/2"±TO WIDEST DEVICE W Z 0 LJL Cw IXISTING HOT -----_ K ------ -- - ----I —__ ____.._____ ._.—__-- �— J EXT'G HVAC KEYPAD,PHONES& 'I' � � � w DOOR CASING EQUIP. I --THERMOSTAT. EXT'G HVAC EXT'G HVAC -- ---- ------ Z U EQUIP. EQUIP, - --------- _2WITCH.- - - 1 SUN RM. I --------- - - SUN RM, EXISTING GYP G NO WORK TO EXISTING -- -------- -OUTO� Horizontal.- .-fl - -y 04 = o - - NO WORK TO EXISTING ___ ________--_ —_____— _ (Ma Occur In Base See { LIGHTING OR SWITCHING I E_ECTRICAL evs -- m 45 EE ELEVATIONS FOR GENERAL ¢ C _ J SEE RCP FOR EQUIPMENT AT CEILING �� P LOCATIONS AND SPECIAL EQUIPMENT N ��5 �MEE Lpp j n� I is -All Lights Shall Be On Dimmers-Electrician To N --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 - - - - - Coordinate Dimmer Types W/ Proper oa329 pQ`' 17 Lj Loading&Light Fixture pF N Vey j -All Smoke/carbon Monoxide Detectors Shall hVA Seal be installed per code FIRST FLOOR REFLECTED CEILING PLAN i FIRST FLOOR ELECTRICAL PLAN i A-201 SCALE: 1/4- 1'0 2 SCALE: 1/4"= 1'0" --a Wall Phone o TV Location 0 HDMI as Required N w -CAT 5&CAT 6(2 each) -Cable V z -Power } w TVBox Location 0 0 -HDMI as Required U w NB -CAT 5&CAT 6(2 each) Lv N -Cable Q w -Power N ¢ Q -Inferred Eye - U w Q _ Ethernet-2 ports at O z N each location w o 0 Siren Lq H D Heat Detector Q 0 WW Water Detector AL(AV) k❑-{ Audio/Vi'deo Alarm Keypad AL(A)❑k -1 Audio Alarm Keypad V F- - -�- 0 ©D Motion Dector VO Volume Control _0 SP Recessed Ceiling Speakers 0 C) Exterior Recessed c o Ceiling Speakers 175 C) SP Bookcase Speaker r v> a, SW Sub-Woofer W o Li WSP Recessed Wall Speaker ^ o LL_ P Wall Mounted,Speaker Exterior Wall ' ESP Mounted Speaker NEW BATH EXHAUST SP Planter Speaker UP TO ROOF TV EXISTING SKYLIGHT I Thermostat MEZZANINE ST GE EDR E Junction Box BEDROOM 2 I�(�M MNIN�S AGE" EXISTING GYP, Duplex Outlet NO WORK TO EXISTING NO WORK TO EXISTING , - ELECTRICAL (IF NOTED TO BE LIGHTING OR SWITCHING Q SWITCHED-TOP OUTLET) U E- Quad Outlet Ground Fault GFI Interrupt Outlet �WP Exterior Outlet(waterproof) Exterior Recessed L RWP Waterproof Outlet o Dedicated Outlet -._-�.. --DUSB USB Outlet Q Duplex Floor Outlet Gas Connector Wire Mold w/Power&Data (See Low Voltage For#Of Outlets/Provide NEW KITCHEN STOVE EXHAUST Receptacle Every 12") UP TO ROOF ( M 8 Smoke/C:arbonmonoxide Detector Ljj N SD Smoke Detector Tied Into Fire Alarm � o aLutron Home Works Switch New Double Pole Switch i Jamb Switch EXISTING SKYLIGHT EXISTING SKYLIGHT ❑ ❑ ❑ Recessed Ceiling Fixture _ Exterior Recessed Ceiling Fixture ❑; Surface Mounted z Ceiling Fixture "' Pendant(Mounted Fixture w ST GEZD o , CeilingFa n n EXISTG GYP, NO WOR 0 EXISTING LIGHTING SWITCHING CH Wall Mounted Fixture ST'TGE _ o NO WORK Tbb EXISTING © Closet/Millwork Fixture "' ELECTRICAL Picture/art Light PLAN Recessed)Linear Ceiling Fixture NORT TRUE EXISTING SKYLIGHT EXISTING SKYLIGHT ❑ ❑ I I ❑ NORTH Wall Mounted Fixture ❑ RWL -- I Recessed Wall Light �PL Path Light 0'-0" Ceiling Height Above Floor Supply Grille pp Y II W U i Return Grille z Ur ® z Access Panel W � ED SS Self Switching FixtureCn U LLj � Fixture Centered CVD U U w ❑ In Space Z Q _, O J > Ly Z ❑ LU ❑ = 0 ,w o� SWITCH+OUTLET m O LOCATIONS DIAGRAM Q �, LJL Q M + W = 0pU 1 1/2_TO WIDEST DEVICE- - �z 3 U_ KEYPAD,PHONES& -DOOR CASING + o cw L j -THERMOSTAT - - ------------ - U -SWITCH. 'Q Qi CD CUTLET-.Houzontol- (May Occur In Base See evs \-- \ m b irr 0 SEE ELEVATIONS FOR GENERAL LOCATIONS AND SPECIAL EQUIPMENT z, ��ERED ARcy SEE RCP FOR EQUIPMENT AT CEILING �\ P�N,EE Lop Fz a -All Lights Shall Be On Dimmers-Electrician To Coordinate Dimmer Types W/ Proper �k Loading&Light Fixture 9�� 04 9 -All Smoke/carbon Monoxide Detectors Shall Seal be installed per code SECOND FLOOR REFLECTED CEILING PLAN 2 SECOND FLOOR ELECTRICAL PLAN A-202 SCALE: 1/4= 1 0 SCALE, 1/4- 1 0