Loading...
HomeMy WebLinkAbout51601-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51601 Date: 02/03/2025 Permission is hereby granted to: 265 Arshamomaque LLC 3 Sandie Ln Manorville, NY 11949 To: Construct new single family dwelling as applied for,with Trustees&DEC NJ letters and SCHD approval. Premises Located at: 265 Arshamomaque Ave, Southold, NY 11971 SCTM# 56.-2-14 Pursuant to application dated 12/02/2024 and approved by the Building Inspector, To expire on 02/03/2027. Contractors: Required Inspections: Fees: CO Single Family Dwelling-New $100.00 Single Family Dwelling.NEW $3,168.50 Total 3 268.50 Building Inspector We TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 littps://www.sotith Idtownn , ors Date Received PERMITAPPLICATION FOR BUILDING i, For Office Use Only PERMIT NO. 604 Building Inspector. Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S) OF PROPERTY: Name:265 Arshamomaque LLC SCTM# 1000-56-2-14 Project Address:265 Arshamomaque Avenue Southold NY 11971 Phone#:631-905-4789 Emall:David@djcustomhomes.com Mailing Address:3 Sandie Lane Manorville NY 11949 CONTACT PERSON: Name:David Roberts Mailing Address:3 Sandie Lane Manorville NY 11949 Phone#:631-905-4789 Email:david@djcustomhomes.com DESIGN PROFESSIONAL INFORMATION: Name:Keri Kazel Architects Mailing Address:2 Windmere court Speonk NY 11972 Phone#:631-874-7377 Email:Keri@kazelarchitects.com CONTRACTOR INFORMATION: Name:DJ Custom Homes Mailing Address:3 Sandie Lane Manorville NY 11949 Phone#:631-905-4789 1Email:david@djcustomhomes.com DESCRIPTION OF PROPOSED CONSTRUCTION RNew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $650,000 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? iRYes ❑No 1 PROPERTY INFORMATION Existing use of property:Vacant Lard Intended use of property:Single Family Home Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 I this property? ❑Yes JONo IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print na David Roberts ❑Authorized Agent BOwner Signature of Applicant: Date: 6/24/2024 STATE OF NEW YORK) COUNTY OF 1f being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the 0 ('� (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 2� 31�day of X/C� ` ��' B Notary Public rrr.all� E RIAA FERREMI -State of rlew Yank () FIEWIT IC I UT RIZ I IIO"IFE6430360inSuffolkCorunty (Where the applicant is not the owner) n Expires guar 14,!2026 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein„ Owner's Signature Date Print Owner's Name 2 Town Hall Annex Telephone(631)765-1802 54375 Main Road m s Fax(631)765-9502 P.O. Box 1179 m Southold, NY 11971-0959 � ° d rxc BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE CONSTRUCTION PRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date: � ;0"tZAz' Owner: '""`. Location of Property: D 4 . Please take notice that the (check applicable line): New commercial or residential structure Addition to existing commercial or residential structure Rehabilitation to an existing commercial or residential structure to be constructed or performed at the subject property reference above will utilize (check applicable line): Truss type construction (TT) Pre-engineered wood construction (PW) Timber construction (TC) in the following location(s) (check applicable line): - Floor framing, including girders and beams (F) Roof framing (R) Floor and ro^fframing (FR) Signature: Name (perso submitting this form): Z* ' Capacity(check applicable line): Owner Owner representative TrussReg15.docx Effective 1/1/2015 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division of Environmental Permits,Region 1 SUNY Cup Stony Brook,50 Circle Road,Stony Brook,NY 11790 P:(631)444-03651 F:(631)444-0360 www.dec.ny.gov LETTER OFNO-JURISDICTION June 20, 2024 265 Arshamomaque LLC 3 Sandie Lane Manorville, NY 11949 Re: Application ID 1-4738-05010/00001 265 Arshamomaque Avenue Southold SCTM # 1000-56-2-14 Dear Applicant: Based on the application your agent submitted and additional New York State Department of Environmental Conservation (DEC) information, DEC has made the following determinations. The proposed project, as shown on the survey of the property by Peconic Surveyors, P.C. last revised May 23, 2024, is more than 100 feet from NYS regulated freshwater wetlands and beyond the jurisdiction of Article 24 Freshwater Wetlands. Please be advised, the wetland located on the east end of the referenced property and shown on the survey, is not currently designated a NYS regulated freshwater wetland.As a result, all activities proposed by this project are located outside of DEC freshwater wetland jurisdiction (100 feet). On January 1, 2025, changes to the NYS Freshwater Wetlands Act, Article 24 of the Environmental Conservation Law will go into effect. These changes will establish a new definition of a NYS regulated freshwater wetland, and the wetland on this lot may become a jurisdictional wetland. At that time, if it is determined to be a jurisdictional wetland, any regulated activities proposed in or within 100 feet of the wetland would require a DEC Freshwater Wetlands Permit. The portion of the referenced property upland (west) of the "Top of Bank", as shown on the aforementioned survey, is beyond the jurisdiction of Article 25 Tidal Wetlands and an Article 25 permit is not required. Please be advised, however, that no construction, disturbance, clearing, discharge, or sedimentation of any kind may take place within 100 feet of NYS regulated freshwater wetlands or below the "Top of Bank" without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Freshwater Wetland and Tidal Wetland jurisdiction which may result from your project. Such precautions may include maintaining an adequate work area between your project (i.e., a 15' to 20' wide construction area) and the 100-foot freshwater wetlands adjacent area or erecting a temporary fence, barrier, or hay bale berm. Be advised, any additional work or modification to the project as described above within 100 feet of the freshwater wetland or below the "Top of Bank", may require DEC authorization. Please contact this office if such activities are contemplated. N '' YORK Department of Oppm� aareav Environmental Conservation DEC has documented the summer occurrence of the Northern Long Eared Bat (NLEB) (Myotis septentrionalis), a species listed as "endangered" by both New York State and the US Fish & Wildlife Service, within 3 miles of the project location. We have determined that tree cutting at this location between March 1 and November 30 of any calendar year may result in the"take" of these endangered species within the meaning of Environmental Conservation Law (ECL) §11-535. The term "take" is defined in part as the direct killing or injury of individual members of a protected species, interference with critical breeding, foraging, migratory or other essential behaviors, or the adverse modification of the species' habitat. The "take" of a species listed as endangered or threatened is prohibited in the absence of a permit from this Department issued pursuant to ECL §11-535. To avoid an Endangered Species t°take" or the need for an incidental take permit, no tree cutting activities can be conducted at the project site between the dates of March 1 and November 30 of any calendar year. If you have questions about the presence of protected species on or near your property, the potential effects of activities on these species or your responsibilities as a landowner or project sponsor under the Endangered Species Regulations, please contact the Regional Wildlife Manager at (631) 444-0310. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from local municipalities or other agencies. Vent truly yours, Sherri L. Aicher Regional Permit Administrator SLA/mrp C: David Roberts BEH BMHP Wildlife File SURVEY OF PROPERTY AT SOUTHOLD TOWN OF SOUTHOLD N SUFFOLK COUNTY, N.Y.1000-56-02-14 SCALE. 1'=30' FEBRUARY B, 2024 MARCH 13, 2024 (REVISIONS) APRIL 1, 2024 (PROPOSED SEP77C SY57rM ADDED) MAY 23, 2024 (CONTOUR LINES ADDED) 7EST HOLE DATA p M.DLWALD OEOSOMCE 3/4/2a24 EL 21.8' DARK BRONW LOAM QL QS' GROW SRT ML PALE:BROW FOL,low N rm VACANT LOT 4 150'\VANDs1Y raz) LINE 100'TOP OF BMK 1 FL ARD SA L2 2 i _ xf I T ice, E Z N t LOT 5 1 an wo $ � � � - ,. �,�"`"'� '•-dam� � - � � 6 � �Y 347.37 ° so KEY l 1 bys�« '�, s 31 p REBAR 5B3'20'10'W LOT 6 PUBLIC WATER Certified ♦ -sTmE $ au1 DWELLING WITH266 Arsh Tomaque, LLC B .TEST HOLE American Dream Abstract, Inc. 0 a p/Pr First American Title Insurance Company —MONUMENT —K?LAND nAO UNLITY POLE _ —WXANDS AREA-26,361 SO. Ff. ` cavnwR 1R�s AND EIEVATKAVs RFEERENTED TO NAM ee ' N.Y,S M. NO: 49618 ANY ALMNATION Orr.ADfMTTOH TO THIS SURKY 15 A WOLA.NON PECONIC SVRWYORS, P.C. NOTE PROPOSED SEPDC SYSY M DESQVED BY ORIERS O SECTIM 720 THE NEW MORK STATE EDUCAT 1 LAiY. LOT NUMBERS REFS, TO 'MAP OF s7E1X I ESTA1 a� EXCEPT PER SEC710A �- IDDt14S Z ALL CERM7CATIONS (631) 765-5020 FAX (631) 765-1797 HMON ARE VAUD FOR THIS 94P AND COPIE5 VHMEOF Oft y IF P.O. BOX 909 BLOCK 2 FILED IN THE SUFFOLK COUNTY CLERKS OL`F10E ON WHOSE D OR CDR%`$BEAR EnRs H MPRESSE0 SEAL OF E SURWYOR 230 N.R 7 971 TLO9-202 MARCH 16, 1946 AS FILE NO. 1472. C�J( Generated by EScheck-Web Software Compliance Certificate Project 265 Arshamomaque Ave Southold, NY 11971 Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 3,159 ft2 Glazing Area 18% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: 265 Arshamomaque Ave Southold, 265 Arshamomaque Ave Southold, Energy Rating Service, Inc Matt NY 11971 NY 11971 Wahl Islip Terrace, NY 11752 631- 566-8439 energyratingservice@yahoo.com Compliance: 7.1%Better Than Code Maximum UA: 534 Your UA: 496 Maximum SHGC: 0.40 Your SHGC: 0.30 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or,performance compliance path nn RCSchec °. Each slab-on­grm de assernbly in the specified climate zone must nie t'tire nininimur°n energy code irnsula'don R-var ue and depth requirements. Envelope Assemblie Prop.Gross Area Assembly or Cavity Cont. Req. Prop. Roof Rafters: Cathedral Ceiling 2,139 38.0 0.0 0.027 0.026 58 56 Wall 1: Wood Frame, 16" o.c. 37 19.0 0.0 0.060 0.060 2 2 Wall 2: Wood Frame, 16" o.c. 8 19.0 0.0 0.060 0.060 0 0 Wall 3:Wood Frame, 16" o.c. 39 19.0 0.0 0.060 0.060 1 1 Window 1: Other 15 0.300 0.320 5 5 SHGC: 0.30 Wall 4: Wood Frame, 16" o.c. 8 19.0 0.0 0.060 0.060 0 0 Wall 5: Wood Frame, 16" o.c. 18 19.0 0.0 0.060 0.060 1 1 Wall 6: Wood Frame, 16" o.c. 21 19.0 0.0 0.060 0.060 1 1 Wall 7:Wood Frame, 16" D.C. 8 19.0 0.0 0.060 0.060 0 0 Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 1 of12 Prop.Gross Area . • Assembly or Cavity Cont. Perimeter Wall 8: Wood Frame, 16" ox. 42 19.0 0.0 0.060 0.060 2 2 Window 2: Other 15 0.300 0.320 5 5 SHGC: 0.30 Wall 9: Wood Frame, 16"o.c. 8 19.0 0.0 0.060 0.060 0 0 Wall 10: Wood Frame, 16" o.c. 18 19.0 0.0 0.060 0.060 1 1 Wall 11: Wood Frame, 16" o.c. 215 19.0 0.0 0.060 0.060 11 it Window 3: Other 30 0.300 0.320 9 10 SHGC: 0.30 Wall 12: Wood Frame, 16" o.c. 97 19.0 0.0 0.060 0.060 4 4 Window 4: Other 30 0.300 0.320 9 10 SHGC: 0.30 Wall 13: Wood Frame, 16" o.c. 147 19.0 0.0 0.060 0.060 9 9 Wall 14: Wood Frame, 16" o.c. 46 19.0 0.0 0.060 0.060 3 3 Wall 15: Wood Frame, 16" o.c. 147 19.0 0.0 0.060 0.060 9 9 Wall 16: Wood Frame, 16" o.c. 97 19.0 0.0 0.060 0.060 3 3 Window 5: Other 52 0.300 0.320 15 17 SHGC: 0.30 Wall 17: Wood Frame, 16" o.c. 10 19.0 0.0 0.060 0.060 1 1 Wall 18: Wood Frame, 16" ox. 50 19.0 0.0 0.060 0.060 2 2 Window 6: Other 15 0.300 0.320 5 5 SHGC: 0.30 Wall 19: Wood Frame, 16" ox. 10 19.0 0.0 0.060 0.060 1 1 Wall 20: Wood Frame, 16" o.c. 34 19.0 0.0 0.060 0.060 2 2 Wall 21: Wood Frame, 16" o.c. 58 19.0 0.0 0.060 0.060 3 3 Window 7: Other 15 0.300 0.320 5 5 SHGC: 0.30 Wall 22: Wood Frame, 16" ox. 32 19.0 0.0 0.060 0.060 2 2 Wall 23: Wood Frame, 16" ox. 81 19.0 0.0 0.060 0.060 3 3 Window 8: Other 30 0.300 0.320 9 9 SHGC: 0.30 Wall 24: Wood Frame, 16" o.c. 66 19.0 0.0 0.060 0.060 4 4 Wall 25: Wood Frame, 16" ox. 8 19.0 0.0 0.060 0.060 0 0 Wall 26: Wood Frame, 16" ox. 39 19.0 0.0 0.060 0.060 1 1 Window 9: Other 15 0.300 0.320 5 5 SHGC: 0.30 Wall 27: Wood Frame, 16" o.c. 8 19.0 0.0 0.060 0.060 0 0 Wall 28: Wood Frame, 16" o.c. 42 19.0 0.0 0.060 0.060 3 3 Wall 29: Wood Frame, 16" o.c. 83 19.0 0.0 0.060 0.060 5 5 Wall 30: Wood Frame, 16" ox. 112 19.0 0.0 0.060 0.060 6 6 Window 10: Other 12 0.300 0.320 4 4 SHGC: 0.30 Wall 31: Wood Frame, 16" ox. 106 19.0 0.0 0.060 0.060 6 6 Wall 32: Wood Frame, 16" o.c. 165 19.0 0.0 0.060 0.060 10 10 Wall 33: Wood Frame, 16" o.c. 496 19.0 0.0 0.060 0.060 22 22 Window 11: Other 42 0.300 0.320 13 14 SHGC: 0.30 Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 2 of 12 Gross Area Cavity Cont. Prop. Req. Prop. Req. Assembly or Window 12: Other 65 0.300 0.320 20 21 SHGC: 0.30 Window 13: Other 26 0.300 0.320 8 8 SHGC: 0.30 Wall 34:Wood Frame, 16" o.c. 15 19.0 0.0 0.060 0.060 1 1 Wall 35:Wood Frame, 16" ox. 130 19.0 0.0 0.060 0.060 6 6 Window 14: Other 15 0.300 0.320 5 5 SHGC: 0.30 Window 15: Other 15 0.300 0.320 5 5 SHGC: 0.30 Wall 36:Wood Frame, 16" o.c. 109 19.0 0.0 0.060 0.060 4 4 Window 16: Other 50 0.300 0.320 15 16 SHGC: 0.30 Wall 37: Wood Frame, 16" o.c. 92 19.0 0.0 0.060 0.060 4 4 Window 17: Other 32 0.300 0.320 10 10 SHGC: 0.30 Wall 38: Wood Frame, 16" o.c. 94 19.0 0.0 0.060 0.060 4 4 Window 18: Other 30 0.300 0.320 9 10 SHGC: 0.30 Wall 39:Wood Frame, 16" o.c. 15 19.0 0.0 0.060 0.060 1 1 Wall 40: Wood Frame, 16" o.c. 56 19.0 0.0 0.060 0.060 3 3 Wall 41: Wood Frame, 16" ox. 74 19.0 0.0 0.060 0.060 3 3 Window 19: Other 31 0.300 0.320 9 10 SHGC: 0.30 Wall 42: Wood Frame, 16" ox. 9 19.0 0.0 0.060 0.060 1 1 Wall 43: Wood Frame, 16" o.c. 18 19.0 0.0 0.060 0.060 1 1 Wall 44: Wood Frame, 16" ox. 62 19.0 0.0 0.060 0.060 4 4 Wall 45:Wood Frame, 16" o.c. 139 19.0 0.0 0.060 0.060 7 7 Window 20: Other 15 0.300 0.320 5 5 SHGC: 0.30 Window 21: Other 15 0.300 0.320 5 5 SHGC: 0.30 Wall 46: Wood Frame, 16" o.c. 18 19.0 0.0 0.060 0.060 1 1 Wall 47:Wood Frame, 16" o.c. 9 19.0 0.0 0.060 0.060 1 1 Wall 48:Wood Frame, 16" o.c. 145 19.0 0.0 0.060 0.060 7 7 Window 22: Other 24 0.300 0.320 7 8 SHGC: 0.30 Wall 49: Wood Frame, 16" ox. 80 19.0 0.0 0.060 0.060 4 4 Door 1: Solid 21 0.290 0.320 6 7 Wall 50:Wood Frame, 16" o.c. 65 19.0 0.0 0.060 0.060 1 1 Door 2: Solid 21 0.280 0.320 6 7 Window 23: Other 10 0.300 0.320 3 3 SHGC: 0.30 Window 24: Other 10 0.300 0.320 3 3 SHGC: 0.30 Overhang:All-Wood Joist/Truss 10 30.0 0.0 0.033 0.047 0 0 Basement Ceiling:All-Wood joist/Truss 1,811 30.0 0.0 0.033 0.047 60 85 Garage Ceiling:All-Wood Joist/Truss 211 30.0 0.0 0.033 0.047 7 10 Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 3 of12 Compliance Statement., The proposed building design described here is consistent with the building plans, specifications„and other calculations submitted with the permit application„The proposed building has been designed to meet the 2018 IECC requirements in REScheclr Version REScheck-Web and to comply with the mM51f uirements : e in h W V4! fr�i *Wahl matthe w' 'cell„, #HERS Rater 2572845 �� +� Date: 04:25:34-0 "00' ...�........... ...............�..�....�.�..,.. ...........,..... ........,.....,. ........�_. ...-.,w.w... �., Name-Title Signature Date ........ ........................ __....... ._. ..-..-... Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 4 of12 CANL REScheck Software Version : REScheck-Web �J( Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Re .ID 1103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the !building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and '❑Complies 103.2, 'documentation demonstrate '❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple :❑Not Applicable dwelling units must demonstrate !compliance with the IECC 'Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies ' 403.7 'sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not j[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable A , Manual J or other methods Btu/hr Btu/hr approved by the code official ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 5 of12 eion 4 Foundation Inspection Complies? Comments/Assumptions &Re, .ID 303.2.1 A protective covering is installed to ❑Complies [FOil]2 protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ❑ grade. Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system controls ❑Complies [FO12]2 installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 6 of12 Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Door U-factor, U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U U- ❑Complies !See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 '❑Not Applicable 303.1.3 U-factors of fenestration products "❑Complies [FR4]1 are determined in accordance ❑Does Not > with the NFRC test procedure or ,taken from the default table. z❑Not Observable ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 'Fenestration that is not site built ,[]Complies [FR20]1 is listed and labeled as meeting ;❑Does Not iAAMA/WDMA/CSA 101/I.S.2/A440; ❑Not Observable - ,or has infiltration rates per NFRC , 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures, ❑Complies [FR16]2 sealed at housing/interior finish `=❑Does Not and labeled to indicate :52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 `for< 3 inches in diameter. 403.3.2 Ducts, air handlers and filter ❑Complies [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with International Mechanical Code or ❑Not Observable International Residential Code, as< ❑Not Applicable ;applicable. 403.3.5 Building cavities are not used as EComplies [FR15]3 ducts or plenums. ❑Does Not a []Not Observable ❑Not Applicable 40 3.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 9F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- ❑Not Observable 3, ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 'Ho 3 p p R- El omplies 403 5.3 Hot water pipes are insulated to R- Does Not ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 7 of12 Section Plans Verified field'Verified Framing d hough-in Inspection Value Value Cc �mlallesiw Comments/Assumptions & Re .ID 403.6 Automatic or gravity dampers are, Dcompnes fFRI912 installed on ail outdoor air 111)oes Not intakes and exhalants. [-]Not Observable '[]Not Applicable Additional Comments/Assumptions, 1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Lour lmpact{Tier 3) Project Title: 26 Arshamornaque Ave Southold, NY 11971 Report date: 0:4/24/24 Data filename: Page 8 of 12 Sect Plans Verified Field Verified Insulation Inspection Value Value ,Cor»plles7' Comments/Assumptions lteti ip 303.1 !All installed insulation is labeled ❑Complies [IN13)2 :or the installed R-values ❑Does Not provided. s❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable f ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.8 manufacturer's instructions and []Does Not [IN2]1 in substantial contact with the `❑Not Observable underside of the subfloor, or floor "framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/z of the ❑ Wood ❑ Wood ElDoes Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ;❑Not Observable [IN3]1 exterior,the exterior insulation ) requirement applies (FR10). Steel ❑ Steel �, ❑Not Applicable 303.2 Wall insulation is installed per ,❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1)___i 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 9 of12 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID g ❑Complies see the Envelope Assemblies 402.2.1, Ceiling insulation R value. ❑R Wood Wood ❑Does Not table for values. 402.2.2, ❑ Steel �, Steel ❑Not Observable 402.2.6 ❑Not Applicable [FI1] 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. '[]Does Not [F12]1 Blown insulation marked every ❑Not Observable 300 ft2. <❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ;❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. i❑Not Observable ; ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air ; handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ftz ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in []Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2.1 Air handler leakage designated ❑Complies [17124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications, ❑Not Applicable . ' �403.1.2 Heat pump thermostat installed ;❑Complies [FI10]2 on heat pumps. ❑Does Not ,[:]Not Observable ❑Not Applicable j 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ;❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) __j Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 10 of12 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 403.E 1 falls not mechanical ventilation system ; ❑Complies z of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits per Table ;[:]Not Observable R403.6.1. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ;❑Not Observable temperature based on outdoor ❑Not Applicable ,temperature. 403.5.1.1 'Heated water circulation systems ` []Complies [F128]z 'have a circulation pump.The iElDoes Not system return pipe is a dedicated return pipe or a cold water supply: �❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal ;for hot water demand within the ; occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ;❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically ❑Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable ,desired water temperature in the piping. i _�a W 403.5.2 Demand recirculation water []Complies [F130]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water ❑Not Applicable piping to <= 1049F. 403.5.4 Drain water heat recovery units ❑Complies [F[31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water ; heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90%or more of permanent ❑Complies [F16]1 fixtures have high efficacy lamps. yDDoes Not ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. i❑Does Not ❑Not Observable ❑Not Applicable 401.3 'Compliance certificate posted, ❑Complies [F17]2 '❑Does Not ❑Not Observable ❑Not Applicable 1 wHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 11 of12 ---------- Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Assumptions &Req.11) 303.3 Manufacturer manuals for Tkomplies [F11813 'mechanical and water heating ,,MDoes Not systems have been provided. []Not Observable ENot Applicable Additional Comments/Assumptions: Project Title; 265 Arshamomaque Ave Southold, NY 11971 Report date: 04/24/24 Data filename: Page 12 of 12 C2018 IECC En�ergy �.(j Efficiency Certificate Isom= MEMO= Above-Grade Wall 19.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Window 0.30 0.30 Door 0.29 miggilijill Heating System: Cooling 'System: Water Heater: all, gownig Name• Date: Comments ACCA Manual DJS HVAC Load Calculations for Residence 265 Arshamomaque Ave Southold, NY 11971 L q i�;""iYIYIW Ras touNM RHVACfWAC LOADS Prepared By; Matt Wahl Energy Rating Service, Inc Islip Terrace, NY 11752 631-566-8439 Wednesday, April 24, 2024 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. ..m.._ ... ......... Rhvac-Residential&right Commercial'HVAC Loads - Elite Software Development,Inc. Energy Rating Service ACCA Manual DJS Islip Terrace„NY 11752 Pa e'2 ..._ General 1 r eot lnf rmati n Project Title: ACCA Manual DJS Project Date: 04/23/2024 Client Name: Residence Client Address: 265 Arshamomaque Ave Client City: Southold, NY 11971 Company Name: Energy Rating Service, Inc Company Representative: Matt Wahl Company City: Islip Terrace, NY 11752 Company Phone: 631-566-8439 Company E-Mail Address: energyratingservice@yahoo.com el; n Ct Reference City: Suffolk County AFB, New York Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 40 Degrees Elevation: 67 ft. Altitude Factor: 0.998 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 10 9 n/a n/a 70 n/a Summer: 83 71 56% 50% 75 30 Che l Ff ure Total Building Supply CFM: 2,600 CFM Per Square ft.: 0.804 Square ft. of Room Area:. 3,232 Square ft. Per Ton: 833 Volume (ft3): 38,888 BiAl n `Loads Total Heating Required Including Ventilation Air: 52,110 Btuh 52.110 MBH Total Sensible Gain: 41,478 Btuh 89 % Total Latent Gain: 5,109 Btuh 11 % Total Cooling Required Including Ventilation Air: 46,587 Btuh 3.88 Tons (Based On Sensible + Latent) Notas Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. D:\ ...\265 Arshamomaque Ave_04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM ............... .............. Rhv I ac Residential&Light Commerotall HVAC Loade Elite Software Development,Inc. ACCA Manual DJS Vac Os "g g LEnergy Rating Service S rvic I Isli Terrace Y errace N sii T Y 11752 8e e 3 ....................................... Load Preview Pe ort Sy sy� Sys Ne�� ft. Se La Net S hit 01g; Ac�, Duc Scope Ton /Toll �Are G Gai, GaJ L Siz, Lose CFMA CFM CFMj .................. ........ fi ............. I............. Building 3.88 833 3,232 41,478 5,109 46,587 52,110 2,600 2,600 2,600 System 1 1.41 1,027 1,443 15,359 1,511 16,870 22,617 1,200 1,200 1,200 12x1'A Ventilation 483 1,126 1,609 3,621 55 55 55 Zone 1 1,443 14,876 385 15,261 18,996 1,200 1200 1,200 12x1 1-Bonus Room 304 3,362 117 3,479 5,603 354 271 271 3­6 2-Bed 3 223 2,947 80 3,027 3,466 219 238 238 3- 3-Bed 2 223 3,600 67 3,667 3,366 213 290 290 3!-- 4-Bath 68 325 0 325 193 12 26 26 1-Al 5-Common Bath 84 614 20 634 1,039 66 49 49 1- 6-Balcony 301 977 25 1,002 1,702 108 79 79 1_6 7-Bed 4 241 3,052 76 3,128 3,627 229 246 246 3•• System 2 2.48 722 1,789 26,119 3,598 29,717 29,493 1,400 1,400 1,400 12x2f Ventilation 483 1,126 1,609 3,621 55 55 55 Supply D uct Latent 331 331 Return Duct 0 58 58 120 Zone 1 1,789 25,636 2,083 27,719 25,752 1,400 1,400 1,400 12x2( 8-Bed 2 160 3,438 0 3,438 3,015 164 188 188 2­6 9-MBed 195 3,744 0 3,744 4,037 219 204 204 2• 10-MBath 195 774 0 774 1,723 94 42 42 1.'5 11-Laundry 73 1,055 0 1,055 992 54 58 58 1_5 12-Kitchen 322 4,678 883 5,561 2,121 115 255 255 3- 1 3-Great Room 492 7,386 400 7,786 9,201 500 403 403 4_6 14-Dining 175 2,919 600 3,519 3,187 173 159 159 2­6 15-Pwdr 22 285 0 285 41 2 16 16 1-- 16-Foyer 154 1,356 200 1,556 1,435 78 74 74 1_6 D:\ ...\265 Arshamomaque Ave04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM Rhvac-Residential&Ught Commercial HVAC Loads Elite Software Developmont,1%'a e "0* ACC Manua)D Energy Rating Service A Manua)DiS j Pa e 4 Page 4 Islip Terrace,NY 11752 Duct g Preview Room or Minimuc Maximum Rough Dw Duo Duc Htg Clg Act, Duct Reg �T Flow Flow Fqw__ So Fact Veloc,�_ Lengl� Size Name Vetoc V loci 0�i L/1 0 Lots Duct --- -------- System 1 Supply Runouts Zone 1 1-Bonus Room Built-in 0 750 0.01 0.1 460.4 354 271 3­6 2-Bed 3 Built-in 0 750 0.01 0.1 403.6 2191= 238 3­6 3-Bed 2 Built-In 0 750 0.01 0.1 493 213r 290 3­6 4-Bath Built-In 0 750 0.01 0.1 300.3 12 0 26 1­4 5-Common Bath Built-In 0 750 0.01 0.1 363 66m� 49 1­5 6-Balcony Built-In 0 750 0.01 0.1 401.5 108 79 1­6 7-Bed 4 Built-in 0 750 0.01 0.1 417.9 229 246 3­6 Other Ducts in System 1 Supply Main Trunk Built-in 0 900 0.003 0.1 847.1 1,200M 1,200 12x1 7 System 2 Supply Runouts Zone 1 8-Bed 2 Built-In 0 750 U1 0.1 478.1 164 188 2­6 9-MBed Built-in 0 750 0.01 0.1 520.6 219 204 2­6 1 G-MBath Built-in 0 750 0.01 0.1 310.1 94 42 1­5 1 1-Laundry Built-in 0 750 0.01 0.1 422.7 54 58 1_5 12-Kitchen Built-In 0 750 0.01 0.1 433.7 15 255 3­6 13-Great Room Built-In 0 750 0.01 0.1 513.6 500 403 4­6 14-Dining Built-In 0 750 0.01 0.1 406 173 159 2­6 15-PMr Built-In 0 750 0.01 0.1 178.3 2 16 1­4 16-Foyer Built-In 0 750 0.01 0.1 377.1 781 74 1­6 Other Ducts in System 2 Supply Main Trunk Built-in 0 900 0.003 0.1 840 1,40mm 1,400 12x20 Summary --------------- ....... ......... .............. System 1 Heating Flow: 1200 Cooling Flow: 1200 System 2 Heating Flow: 1400 Cooling Flow: 1400 D:\ ...\265 Arshamomaque Ave04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM Rh^vac-Residential&Light Commercial HVAC Loads Elite Software Developmen Inc,Energy Rating Service ACCA Manual DJS Isli Terrace;NY 11752 9e e Total B ri92g Summ iry Loads Q po e Area Sere Lat 5qn Total l es ri it"Con Quan Loss Gain Gain Gain U:0.30, SHGC:0.30: Glazing-U:0.30, SHGC:0.30, U-value 609.7 10,975 0 15,250 15,250 0.3, SHGC 0.3 11 P: Door-Metal - Polyurethane Core, U-value 0.29 21 365 0 116 116 11 F: Door-Wood- Solid Core With Metal Storm, U-value 21 353 0 112 112 0.28 12E-Osw:Wall-Frame, R-19 insulation in 2 x 6 stud 2833.9 11,562 0 2,003 2,003 cavity, no board insulation, siding finish, wood studs, U-value 0.068 r38: Roof/Ceiling-Roof Joists Between Roof Deck and 2409.5 4,626 0 771 771 Ceiling or Foam Encapsulated Roof Joists, Custom, R-38 open cell 1/2 lb. spray foam, 10.5 inches in 2 x joist cavity, U-value 0.032 20P1-30op: Floor-Over open crawl space or garage, 209.3 439 0 22 22 Passive, spray foam insulation, R-30 open cell 1/2 lb. spray foam insulation, 8 inches in 2 x 10 joist cavity, any cover, U-value 0.035 19A-30p: Floor-Over enclosed crawl space, No insulation 1810.7 3,100 0 414 414 on exposed walls, sealed or vented space, passive, R-30 blanket,mU-value 0.034 .. ._.. ma _...__..._ _._�..r... ... _�. .. ._.... .. .. .�_.._ ._ .......... _ _ Subtotals for structure: 31,420 0 18,688 18,688 People: 7 1,400 1,610 3,010 Equipment: 683 15,714 16,397 Lighting: 800 2,728 2,728 Ductwork: 2,618 389 643 1,032 Infiltration:Winter CFM: 164, Summer CFM: 19 10,829 385 165 550 Ventilation:Winter CFM: 110, Summer CFM: 110 7,242 2,252 966 3,217 AED Excursion: 0 0 965 965 Total Building Load Totals: 52,110 5,109 41,478 46,587 Check Figures Total Building Supply CFM: 2,600 CFM Per Square ft.: 0,804 Square ft. of Room Area: 3,232 Square ft. Per Ton:. 833 Volume (ft3): 38,888 Bu�uldii� Loads Total Heating Required Including Ventilation Air: 52,110 Btuh 52.110 MBH Total Sensible Gain: 41,478 Btuh 89 % Total Latent Gain: 5,109 Btuh 11 % Total Cooling Required Including Ventilation Air: 46,587 Btuh 3.88 Tons (Based On Sensible + Latent) rotas Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. D:\ ...\265 Arshamomaque Ave_04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM ........ ....... ............ Rhvac-Ftest ttal L19,ht omrnerolal H AC;Loads _v_ Elite Softwa re Development,Inc.' Energy Rating,,Service ACCA Manual DJS lsli 1Cerrace NY' 1175 --Lase-6 �... ...... ............................. ...... .... m F err n ent Data - 5 stem 1 - 2nd Floor Cooling System Type: Standard Air Conditioner Outdoor Model: RA1 636AJ1/RH1 P3617STA Indoor Model: RA1636AJ1/RH1P3617STA Outdoor Manufacturer: RHEEM Indoor Manufacturer: RHEEM Capacity: 33,200 Efficiency: 14.5 SEER This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 83F, SOWB: 71 F, WODB: 10F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain:. 15,359 Btuh, Lat. gain: 1,511 Btuh, Sen. loss: 22,617 Btuh, Entering clg. coil DB: 75.4F, Entering clg. coil WB: 62.9F, Entering htg. coil DB: 67.2F, Clg. coil TD:20F, Htg. coil TD: 70F, Req. clg. airflow: 678 CFM, Req. htg. airflow:247 CFM D:\ ...\265 Arshamomaque Ave_04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM ........ _. ----- h -Ike 'Ontiat Light Commercial I�VAC Loade Elite Sottanr re l tevAlopment,,Inc. Energy Rating Service ACCA Manual Di ili Terrace NY 11752 I'e e 7 .._ .00r Cooling System Type: Standard Air Conditioner Outdoor Model: RA1642AJ1/RH1P4821STA Indoor Model: RA1 642AJ1/RH1 P4821STA Outdoor Manufacturer: RHEEM Indoor Manufacturer: RHEEM Capacity: 41,000 Efficiency: 14.5 SEER This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB:83F, SOWB: 71 F, WODB: 10F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 26,119 Btuh, Lat. gain: 3,598 Btuh, Sen. loss: 29,493 Btuh, Entering clg. coil DB: 75.3F, Entering clg. coil WB: 62.9F, Entering htg. coil DB: 67.6F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1168 CFM, Req. htg. airflow: 335 CFM D:\ ...\265 Arshamomaque Ave_04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM _. .. ..... Rhvao-Residential&Llght+Connmerolal HVAC Loads Mite Software Development,Inc. Energy Rating Service ACCA Manual DJS Islip"Terrace NY 11752 Page 8 Manual S Performance Data - , stem 1 - 2nd Floor oasaind Deai n'Corlditidh Cooling: Outdoor Dry Bulb: 83 Sensible Gain: 15.359 Outdoor Wet Bulb: 71 Latent Gain: 1.511 Indoor Dry Bulb: 75 Total Gain: 16.870 Indoor RH: 50 Load SHR: 0.91 Supply Airflow: 1,200 Entering Dry Bulb: 75.4 Entering Wet Bulb: 62.9 Heating: Outdoor Dry Bulb; 10 Sensible Loss: 22.617 Indoor Dry Bulb: 70 Entering Dry Bulb: 67.3 Indoor RH: 30 Supply Airflow: 1,200 E� uf`rnent`Perforr Performance,Data at,§y§tema D si m C nditions- This system's equipment was selected in accordance with ACCA Manual S. Cooling: Model Type: Standard Air Conditioner, Outdoor Model: RA1636AJ1/RH1 P3617STA, Indoor Model: RA1636AJ1/RH1 P3617STA Nominal Capacity: 33.200, Manufacturer: RHEEM Entered Inter olation Data: EDB : Total Power 75.4 OF EWB Air Flow ODB OF CFM of Capacity Input Sensible: MBtuh kW S!T Capacity' M Btu h 62:.w.. .. 120 83. ...._ 33.2 2.86 0.78.., �ow.w. 2 ,..�.... ,we......, .. 3 Interpolation Results: Percent Load of Load Sensible Capacity: 26.000 15.359 169% Latent Capacity: 7.200 1.511 477% Total Capacity: 33.200 16.870 197% Power Input: 2.86 Heating: Model Type: Propane Furnace, Model: , Nominal Capacity: 64.000, Manufacturer: WEIL MCLAIN Results: Percent Load of Load Heating Capacity: 64.000 22.617 283% D:\ ...\265 Arshamomaque Ave_04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM ............__ Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Energy Rating Service ACCA Manual DJS Islip Terrace NY 11752 Page 9 Manual S Performance Data - . stem 2 -mmmm1st Floor Loads and Design Conditions Cooling: Outdoor Dry Bulb: 83 Sensible Gain: 26.119 Outdoor Wet Bulb. 71 Latent Gain: 3.598 Indoor Dry Bulb: 75 Total Gain: 29.717 Indoor RH: 50 Load SHR: 0.88 Supply Airflow: 1,400 Entering Dry Bulb: 75.3 Entering Wet Bulb: 62.9 Heating: Outdoor Dry Bulb: 10 Sensible Loss: 29.493 Indoor Dry Bulb: 70 Entering Dry Bulb: 67.6 Indoor RH: 30 Supply Airflow: 1,400 ui rrierlt'Perfotmfince'Data'at System Design Conditions This system's equipment was selected in accordance with ACCA Manual S. Cooling: Model Type: Standard Air Conditioner, Outdoor Model: RA1642AJ1/RH1 P4821 STA, Indoor Model: RA1642AJ 1/RH 1 P4821 STA Nominal Capacity: 41.000, Manufacturer: RHEEM Entered Interpolation Data: .. EDB Total Power 75.3°F EWB Airlo+ , ODB ...w...._........ � OF CFM of Capacity' Input' Sensible MBtuh kW , S/T Capacity) MBtuh 62. .w._., 140� v,._,.-83�w ,.41 3.28 0.732, 3 Interpolation Results: Percent Load of Load Sensible Capacity: 30.000 26.119 115% Latent Capacity: 11.000 3.598 306% Total Capacity: 41.000 29.717 138% Power Input: 3.28 Heating: Model Type: Propane Furnace, Model: , Nominal Capacity: 86.000, Manufacturer: WEIL MCLAIN Results: Percent Load of Load Heating Capacity: 86.000 29.493 292% D:\ ...\265 Arshamomaque Ave_04232024 ACCA Manual DJS.rh9 Wednesday, April 24, 2024, 4:28 AM .............................. ........................ D-1—PD: Whisper0reen@ Setect w Fan, 110-130-150 CFI HERO@ 15CH-EC Fresh Air Applia jj�� 7.-J-t 7;P Item M:463253 Vdri—th ZINDAHAIER MERV 3(d.f..It) PRODUCT n'MILS 7 JT.IF.rT--r- •ir,• -I—F-•.<i: -.ir zc r--.rr -T.jiC-1-i:AJ.7-.I.7 l.T SIMILAR MODEL DawrAill PD:: ECO-Touch@ Auto IAQ control "C :Ic,.,!Jr-CT .:jr.r,r= :Jr'D.-T' TVC L,- I I U U1 1,'LIL: Item k.414727 �A I :j'n CxLir?;ic Sr 17 m r i r OR APPROVED SIMILAR MODEL ............. obb Kft"" �ACTOIR ou"r"n as FORIM, AFTACH 0.4,0. 1AIWING ON JOBSITT 11:OR 11'.)IRECTIONS TO SUB COIN FIRACTORS IAQ INDOOR AIR QUALITY - V1 REQUIRED:110 GPD/BEDROOM = 550 GPD J. PONTIERI, P.E., D.P.C. PROVIDED: FUJI CEN-7 =700 GPD ENGINEERING & CONSULTING SANITARY LEACHING POOL DESIGN* 16 Commercial Blvd. E �O REQUIRED FOR 5 BEDROOM SYSTEM:400 SF OF LEACHING AREA Suite 1A Medford, NY 11763A4' PROVIDED: (2) PROPOSED 8 FT DIAMETER LEACHING POOLS x 8' E.D. 637.320.7040 telephone (2) LEACHING POOL x 25.1 SF/VF x 8 VF = 401.6 SF OF LEACHING AREA. Office@jp-ce.com 50%EXPANSION C7 097 8E (1) PROPOSED 8 FT DIAMETER LEACHING POOL NOT TO BE INSTALLED AT THIS TIME P'E'G10 rro� O '� t 95 h5w�9fiN.t#'A9 a SUE SECI ION 7;W CAE AR ME PE 1505 47�TEUk DESIGN REQUIREMENTS ARE BASED OFF OF SCDHS STANDARDS FOR ANYD ct)MENT114AI S'FR NSTNEgALUAFA RPESME7�hU.�EHi CONSULTING ENGINEERs ANY��'��������5 WAT°��� ���5E+4G.43E�`aRc7FE559t7N4'vV. APPROVAL OF PLANS AND CONSTRUCTION FOR SEWAGE DISPOSAL SYSTEMS ENGINEER UNLESS THEPkR$ON1$ACING ONDERTHE GIPIELJJON Or A EUE'�MED FE.d9F•E55IONAL ENGINEER FOR SINGLE-FAMILY RESIDENCES DATED DECEMBER 29, 2017. PROJECT 265 Arshamomaque, LLC ('2)PROPOSED 8 FT DIAMETER (1)FUTURE 265 Arshamomaque Avenue LEACHING POOI.x 8' E.D. EXPANSION POOL rOVa NY 11971 FINISHED GRADE SC D H S Ap p Southold, 90 Town of Southold ............ ... . SCTM No.:1000-56-02-14 ISSUE DATE ISSUED FOR - � 3/20/24 SCDHS Review TFF L K MENT OF HEALTH SERVICES ® ® ®® um ® ® ®®® FPSUFFOLK L OF CONSTRUCTION FOR A ® ® ® ®Elm ® ® ® ®®® SINGLE FAMILY RESIDENCE O LY '-1 & LP-2 EX R-24-0419 DATE 1/6/25 , . �...... G - """'"" THESE DRAWINGS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OFJ.PONTIERI,P.E.,D.P.C.ANY INFRINGEMENTS ON THIS COPYRIGHTED APPROVEDMATERIAL WILL BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW .�.�--- -01 DRAWING T1T"LE 6 BEDROOMS PROJECT#: 2024-1 N.T.S. FOR MAXIMUM OF Sanitary EXPIRES THREE YEARS FROM DATE OF APPROVAL DRAWN BY: DP System Plan DATE: March 19, 2024 DRAWING NUMBER SCALE • As Noted - 1 1 OF 2