HomeMy WebLinkAbout51585-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: S1585 Date: 01/24/202S Permission is hereby granted to: Mauri-Knise R Rev Trt 5765 Stillwater Ave Cutchogue, NY 1193S To: Construct interior alterations to convert an existing attached garage into an office and bathroom as applied for. Premises Located at: 5765 Stillwater Ave, Cutchogue, NY 11935 SCTM# 137.-4-5.1 Pursuant to application dated 11/25/2024 and approved by the Building Inspector. To expire on 01/24/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Alteration $374.00 CO Single Family Dwelling-Addition /Alteration $100.00 Total $474.00 Building Inspector roFa TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 " Telephone(631) 765-1802 Fax (631) 765-9502 litt s://www.soutlioldtov-nn.y.gov a tir DatB Received APPLICATIONI For Office Use Only PERMIT N0. 5 1 15 LJ 5 Building Inspector:, J P 1, Applications and forms must be filled out In their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 11- 1 S — 'Z OWNER(S)OF PROPERTY: Name: 0 >1L V�'V- `— SCTM #1000- Project Address: s b5 -r v -r G 0 V se- Phone#: 0� 2 - (Zb 2 Email:fRPANK=i4t9v%eA0RYa2c& mi4ll.. CZ Mailing Address: 'L W INT V-,Ae '.r G FF- CONTACT PERSON: Name: " � N Mailing Address: Z� , 11J 1r� Ica - 11� 01,' ` Phone#: G Email: E) DESIGN PROFESSIONAL INFORMATION: Name: 5� u L vm IV Mailing Address: 2 b Phone#: „ rEmail:K,, 19 „ )i- 1° � M81'(...., . CONTRACTOR INFORMATION: Name:, Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition Iteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other P"g W--' 4 -0 N V IS19 5kv Will the lot be re-graded? ❑Yess.�40 Will excess fill be removed from premises? ❑Yes'XNo 1 PROPERTY INFORMATION Existing use of property: I Ly Intended use of property: ` C t)W 1,--Lt. m dj P OV Of,Lt 7 N Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ❑No IF YES, PROVIDE A COPY. .CXCheck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permrt pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable law-ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and In building(s)for necessary Inspections.Falser statements made herein'are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. AApplication Submitted B Jl�N SG LquVv)r9,r j pp y(print m >4uthomized Agent ❑Owner Signature of Applicant• Date: STATE OF NEW YORK) I SS: COUNTY OF Sly ifr o C" .. , IN being duly sworn, deposes and says that ii.$)he is the applicant (Name of individual signing contract) above named, (S)he is the G. �— (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this dayof U '\ 2�r 120 FUMY M.IYNCH � Not ubic Notary Public,Stale Of New York 14m 01LY61 0109 ivaliii d in S�ff;1k oun Commission ixPares July 24, (Where the applicant is not the owner) residing at c (0 + -AA-151 L U fi7--- do, hereby authorize on AN to apply on my lbe"W Town of Southold Building Department for approval as described herein. Ib - 30 - 2 `I r" i atu�re Date Print Owner's Name 2 Generated by REScheck-Web Software Compliance Certl fficate Project Digregorio Energy Code: 2018 IECC Location: Cutchogue, New York Construction Type: Single-family Project Type: Alteration Project SubType: None Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: 5765 Stillwater ave Kenneth Schulman Cutchogue, Ny 11935 Kenneth Schulman architect pc 209 Lynn ave East northport, Ny 11731 631-368-2388 Ksarchitectl@gmail.com • trade-off Compliance: 6.9%Better Than Code Maximum UA: 58 Your UA: 54 Maximum SHGC: 0.40 Your SHGC: 0.20 The%Better or worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the QUA or pel-f rrri`iance corn i:lflianca path in RE'Schec . Each Saab-on grade assemrrmbl ^In the spmet:ified clwniate zone must meet the rrminimuni energy code insulation R-value and depth requirements, Envelue.Assemblies Gross Area Assembly or Cavity Cont. Prop. Req. Prop. Req. Ceiling: Flat Ceiling or Scissor Truss 312 30.0 0.0 0.035 0.026 11 8 Wall: Wood Frame, 16" D.C. 321 19.0 0.0 0.060 0.060 17 17 Door: Solid Door(under 50%glazing) 20 0.260 0,320 5 6 Window:Vinyl Frame SHGC: 0.20 15 0.260 0.320 4 5 Floor: All-Wood joist/Truss - 239 30.0 0.0 0.033 0.047 8 11 Window: Vinyl Frame SHGC: 0.20 15 0.260 0.320 4 5 Door: Solid Door(under 50%glazing) 20 0.260 0.320 5 6 Project Title: Digregorio Report date: 11/10/24 Data filename: Page 1 of10 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory require nts ' in the REScheck Inspection Checklist. � OEDA Dame-Title Si nat ra �� Date 4 A ^, m r ^.,Q65 NO31 P Project Title: Digregorio Report date: 11/10/24 Data filename: Page 2 of10 REScheck Software Version : REScheck-Web Inspection Checklist Energy side: 2018IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section& Re# ID Pre-Inspection/Plan Review Plans Vefie iel Veirified Complies? s? Comments/AssumptionsVallu Value 103.1, Construction drawings and GComplies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the m, 'building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ®Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate 'compliance with the IECC Commercial Provisions. ...... ..M _... ... . ................ ........................... ................................. 302.1, Heating and cooling equipment is g 9 MComplies �... 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable Btu/hr Btu/hr ❑Not Applicable approved by the code official. PP Additional Comments/Assumptions: 1 Htgh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Digregorio Report date: 11/10/24 Data filename: Page 3 of10 Section # Foundation Inspection Complies? Comments/Assumptions &Rerq.10 303.2.1 �A protective covering is installed to ❑Complies (F01112 protect exposed exterior insulation ❑Does Not -and extends a minimum of 6 in. below ; ;grade ❑Not Observable; jI11\lot Applicable 403 Snow-and ice-melting system controls,❑Complies [F 12]2 installed. ❑Does Not '❑Not Observable 41\lot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Digregorio Report date: 11/10/24 Data filename: Page 4 of10 Section Plans Verified Field Verified # Framin _ Inspection Value Value Complies Comments/Assumptions & Req.ID �.. .g/Rough-In.._ e. �._ �. — _... ... _,. .. .._._. _ ...w... 402.1.1, Door U-factor, U ZG U- INComplies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable I'?,, ❑Not Applicable 402.1.1, average).factor(area-weighted M/- U ❑Does Not See the Envelope Assemblies Glazing 9 p g t table for values. 402.3.3, [-]Not Not Observable [FR2]1 ❑Not Applicable . . ............. __.... .........................._ ........ .._........... 303.1.3 U factors of fenestration products 'INComplies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. [:]Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier MComplies [FR23]1 installed per manufacturer's ❑Does Not a instructions. ❑Not Observable ❑Not Applicable .�... 402.4.3 Fenestration that is not site builtComplies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting g g fixtures SComplies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate :52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable _ ....... .. .. 40 3.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches.Supply and ❑Not Observable return ducts in other portions of 8Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.2 Ducts, air handlers and filter ❑Complies - [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with International Mechanical Code or ❑Not Observable International Residential Code, as NNot Applicable applicable. 403.3.5 Building cavities are not used as MComplies [FR15]3 ducts or plenums. ❑Does Not � ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not y below 55 °F are insulated to >_R- ❑3 Not Observable ENot Applicable .403. � . 4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not < + ❑Not Observable NNot Applicable 403.5.3 Hot water R es i are insulated to R-� m � �IComplies pipes� � � [FR18]2 >_R-3. ❑Does Not :❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Digregorio Report date: 11/10/24 Data filename: Page 5 of10 ed _ em_.... . ....m �M �►In Mug FIIIeI VaII ._..I71—e ._.SFraimin /Ita h In Ins e�ctionue oI amrwmrents/Assum than ISwC .10 _.._ .. D . Automatic or gravity dampers are ISornplies [F 19]2 installed on all outdoor air C D'oes Not intakes and exhiausts. ❑Not Observable ®Not Applicable Additional CAmme_rxts/As;sumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) Low Impact(Tier 3,] Project Title. Digr+ gorio 'Report date: 11/10/24 Data filenanme, Rage 6 of10 Section p Plans Ver fled FieldVerified Complies? P,s?. ent sump. . mments/Assumptions Value# Insulation Inspection Com lies Co & Re ID Value 303.1 All installed insulation is labeled � -�Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable _ 402.1.1, Floor insulation R-value. R- 3E....... .... ..e R HCo mplies See the Envelope Assemblies 402.2.6 Wood ❑ Wood ❑Does Not table for values. [IN111 ❑ Steel ❑ Steel ❑Not Observable i; ❑Not Applicable 303.2, Floor insulation installed per Complies 402.2.8 manufacturer's instructions and ❑Does Not [IN211 in substantial contact with the underside of the subfloor, or floor ❑Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous :insulation is installed on the underside of floor framing and :extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a Rr� _ �_R- Complies See the Envelope Assemblies 402.2.5, mass wall with at least V2 of the table for values. Wood ❑ Wood ❑Does Not 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN311 exterior„the exterior insulation requirement applies]FR10), ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per Complies [IN411 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: ................ .. ..._.................._.............._.__ ......_.........._�.. ...........�..........._.........__._ . .......................... 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Digregorio Report date: 11/10/24 Data filename: Page 7 of10 Section Plans Verified FieldVerified ID 1--__ a & Re # Final Inspection Provisions Value Value Complies? Comments/Assumptions 402.1.1, :Ceiling insulation R-value. R- .-4 B R- WComplies See the Envelope Assemblies 402.2.1, Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [Fill' ❑Not Applicable 303.1.1.1, ;Ceiling insulation installed per wComplies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ���aplies [F122]2 insulation include baffle adjacent Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R � ❑Complies [F13]1 Jnsulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable 'Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable NNot Applicable 403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch NNot Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in []Not Observable tests, verification may need to SNot Applicable occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated ❑Complies [F124]1 :by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable INot Applicable 403.1.1 Programmable thermostats WComplies [Flg]2 installed for control of primary ❑Does Not :heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 ;Heat pump thermostat installed ❑Complies [FI10]2 :on heat pumps. ❑Does Not ❑Not Observable NNot Applicable 403.5.1 �:Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable GNot Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Digregorio Report date: 11/10/24 Data filename: Page 8 of10 on Provisions anValueVerified Field Verifiedlies' & Re ID Se ion Final —Inspection � . PI... s� Comments/As 403.6.1 All mechanical ventilation system []Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and airflow limits per Table ❑Not Observable R40_3.6._1. (NNot Applicable .403.2 Hot water boilers supplying heat .._ ....._..... ,_ ❑Complimm � es [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water [-]Not Observable temperature based on outdoor 'I@Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- *Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 03.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the Not Applicable desired water temperature in the piping. 403.5.2 Demand recirculation water ❑Com lies [F130]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water *Not Applicable piping to <= 1049F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ANot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90%or more of permanent 'MComplies [F16]1 fixtures have high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable flNot Applicable ..-�.._ .._.. .. .................______..................___� i401.3 Compliance certificate posted,. ❑Complies [F17]2 ❑Does Not ❑Not Observable JINot Applicable 2�M-edium Impac Impact(Tier 2) 3 Low t(Tier 3) 1 Hags Impact(Tier 1) Project Title: Digregorio Report date: 11/10/24 Data filename: Page 9 of10 wetion Value V ._ a�.. � .. # &Fte ID c ProvisionsµW .. aluefied nts/Assumptions Final Inspection� _ .._� Pans Ven ie Fie Complies? Comme 03, Manufacturer manuals for ❑Complies [FI1"8]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable *Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Digregorio Report date: 11/10/24 Data filename: Page 10 of10 Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 19.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 30.00 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.26 0.20 Door 0.26 Cooling Heating System: Cooling System Water Heater: Name: Date: Comments Town Hall Annex �� °�rz Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O. Box 1179 Southold, NY 11971-0959 a BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE CONSTRUCTION PRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date: S `f Owner: N Location of Property: v la 2 e— C_ U >E Please take notice that the (check applicable line): New commercial or residential structure Addition to existing commercial or residential structure Rehabilitation to an existing commercial or residential stru:ture to be constructed or performed at the subject property reference above will utilize (check applicable line): M, A.._ Truss type construction (TT) Pre-engineered wood construction (PW) Timber construction (TC) in the following location(s) (check applicable line): Floor framing, including girders and beams (F) Roof framing (R) Floor and roof framing (FR) Signature: Name (person submitting this form): � � Capacity(check applicable line): Owner Owner representative TrussReg15.docx Effective 1/1/2015 S.C.T.M. NO. DISTRICT: 1000 SECTION: 137 BLOCK: 4 LOT(S):5.1 /STILLWATER AVENU EDGE Of flAVEMEW E t —_5---- --_ —_--- W. —''m 150.00' APE N55'e15'00"S _— — EL 3.8 zoN ( s) tea c ZONE x - N�'"" `N r y I LOT 15 .:. % I ICs 'A % L 6.7 Lar16 It 71.4" .."w ... .,,I 1 UM N/F z N EL ,OE FRM. 1 DOU"&MO*LE GMM'SKI O O I .. ,, 1 LY1 {�MNG �-2D' 17 2 V w 5765 I QIi I C EL 7 3 ID D I I CA Tt FRAME U w 1w I w 03`SEL o __ 5 .: --"--D 1 .17*, EL 3.0 WOOD sotww VOW ? r 55.00' swIID''' 2.1ETWAL WETLAND BOUNDARY w AS DELINEATED BY FILED MAP 4a P LOT 1+1 r y EN—CONSULTAHM 06-02-22 LOT LId!VE BWNDARY I wYAx "w . " T, W G LET" RACK P/O LOT 14 C9 LAND NIF OF 4 MIC94M h JOAN FLMT I I a F'y, I r 1 r 1 1 NOTE 1 ° RECORDED DEED LIBER 11246 PG. 378 DIFFERS FROM LOT LMIE MOOMMM. r REAL PROPERTY TAX SERVICE AWICY OF SUFFOLK COUNTY DOCUMENTS DA70 w EUGENE CREEK SEPf. 24, 1974 REFEROCE REWMEW OF PREVIOUS LOT NUMBER AND MEWONS. C4nVAjX 7"LvAT LOT MENS9ONS AS SHOWN ARE FROM FIELD ORMAIM, COMPUTATIONS AND DATA OBTAW r FROM OTHERS. THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL 14 LOCA77ONS SHOWN ARE FROM RELD OBSERVA7101VS . AND OR DATA OBTAINED FROM OTHERS. " rLOAT FIRM MAP #36 i 03C0163H °. AREA: 10,274 SQ.FT. or 0.24 ACRES ELEVA7701V DATUM: NAVD88 `. UNAU7HOR12ED AL7ERA770N OR ADD17701V TO THIS SURVEY IS A WOLAAON OF SEC71ON 7209 OF 7HE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'SEMBOSSED SEAL SHALL NOT BE CONSIDERED70 BE A VAUD 7RUE COPY. GUARANTEES IND/GATE!) HEREON SHALL RUN ONLY 70 THE PERSON FOR WHOM THE SURVEY IS PREPARED'AND ON HIS BEHALF 70 THE 777LE CaWPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES 70 THE STRUCTURE'S ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT 7HE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES,, ADD177ONAL STRUCTURES OR AND 07HER/MPROVEMEN7S FASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECaVM ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT 7HE 77ME OF SURVEY SURVEY OR LOT 15 & P/0 LOT 14 CERTIFIED TO: FRANK DIGREGORIO; MAP OR FLEETWOOD COVE FILED: JULY 1, 1938 No.1263 S17UATED AT: CUTCHOGUE TOWN OF, SOUTHOLD KENNETH M WOYC UX LAND SURVEY N , P UPDATE & STAKE DOCK 06-27-24 REVISE PROP. CATWALK DOCK LOCATION 06-24-24 SUFFOLK COUNTY, NEW YORK Professional Land Surveying and DeaiLgu / P.O. Box 159 Aquebogue, New York 11931 STAKE PROP. SHED 02-15-23 EFILE # 4-161 scaLE: 1"=30' DAB:OCT. 24, 2014 PHONE (ew)298-iaBe FAX (631) ZM-15M ADD PROP. SHED 01-21-23 N.Y.S. LISC. NO. 050682 malntetoft the reoor&of Bobwt L Umnaae7 a Esnneth IL Xo7%at