Loading...
HomeMy WebLinkAbout29432-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-30234 Date: 06/08/08 THIS CERTIFIES that the building ALTERATION Location of Property: OCEANIC AVE FISHERS ISLAND (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 9 Block 7 Lot 11.1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MAY 27, 2003 pursuant to which Building Permit No_ 29432-Z dated MAY 28, 2003 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is WIRELESS COMMUNICATIONS ANTENNA INSTALLED IN AN EXISTING CHURCH BUILDING AS APPLIED FOR PER SPECIAL EXCEPTION ZBA 45311 DATED 5/15/03. The certificate is issued to OUR LADY OF GRACE RC CHURCH (OWNER) , of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO_ 1197379 03/09/04 PLUMBERS CERTIFICATION DATED N/A uthor zed Signature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29432 Z Date MAY 28 , 2003 Permission is hereby granted to : LADY OF GRACE RC OUR PO BOX 425 FISHERS ISLAND,NY 06390 for CONSTRUCTION OF A WIRELESS COMMUNICATIONS ANTENNA IN AN EXISTING CHURCH BUILDING AS APPLIED FOR at premises located at OCEANIC AVE FISHERS ISLAND County Tax Map No. 473889 Section 009 Block 0007 Lot No. 011 . 001 pursuant to application dated MAY 27, 2003 and approved by the Building Inspector to expire on NOVEMBER 28 , 2004 . Fee $ 200 . 00 Author ze Signature ORIGINAL Rev. 5/8/02 Form No.6 IF TOWN OF SOUTHOLD BUILDING DEPARTMENT I�_ TOWN HALL ao1� 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$25.00 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential $15.00, Commercial $15.00 Date. NO I oil I2 001 New Construction: Old or Pre-existing Building: ✓ (check one) Location of Property: OCEANIC AVE F-ISHEKS ISLAMD House No. Street Hamlet Owner or Owners of Property: LAW OF GRACE CSC. OUR Suffolk County Tax Map No 1000, Section Oct Block Lot i I . Subdivision Filed Map. Lot: Permit No. Aq 1}'�jZ Date of Permit 05 3 Applicant: LAN OF (��E R `r' OUR Health Dept. Approval: Underwriters Approval: 3f q&q (a@EQcj W) Planning Board Approval: / Request for: Temporary Certificate Final Certificate: V (check one) Fee Submitted:$ So .C)r1 t �I _I _�,Z Applicant Signature o Im 5 5 BY THIS CERTIFICATE OF COMPLIANCE HE NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 55 5 CERTIFIES THAT S 5 Upon the application of upon premises owned by 5 BBID REMODELING AND RESTOR. OUR ALPINEDYOF GRACE O5 FISHERS ISLAND, NEW YORK 06390, FISHERS ISLAND, NY 06390 c 5 Located at 33 ALP9ENUE FISHERS ISLAND, NY 06390 Application Number1973 Certificate Number: 1197379 5 ,lc Section: Block: Lot: Building Permit: BDC: nsl 1 C5� Described as a Commercial occupancy,wherein the premises electrical system consisting of �c 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 Basement, 5 5 was inspected in accordance with the National Electrical Code and the detail of the installation,as set forth below,was 5 found to be in compliance therewith on the 9th Day of March, 2004. 5 Name OTY Rate Rating Circuit Type 5 Dj Alarm and Emergency Equipment rj Sensor 1 0 Smoke 5 5 Combo Exit and Emergency Light 1 0 5 5 Transfer Switch 1 0 200 amp 5 5 Appliances and Accessories 5 Exhaust Fan 1 0 F.H.P. �+ 5 Wiring and Devices 5 5, Receptacle 3 0 General Purpose ISwitch 3 0 General Purpose 5 5 Fixture 2 0 Fluorescentsli 5 ISM 5 5 5 IN ISM S 5seal 5 1 of 1 This certificate may not be altered in anyway and is validated only by the presence of a raised seal at the location indicated. 5 5 5 0 L3rL3 3PCj@ rJ�r rL cncn cn rJrJr nrJr�r r1rJrJr ncnrJrJrltrrRPLrL3r@rL3 @r@rL3L3rL3r.rdnr�cnrr�cnc n rr� rJ�rJr�r�rJ� PLIo 05/23/2003 15:41 6317659064 ZONINGAPPEALSBOARD PAGE 01 APPEALS BOARD MEMBERSgUFFO�� Southold'''own Hall 53095 Main Road Lydia A. Tortora, Chairwoman �T P.O.Box 1179 Gerard P. Goehringer ; George Horning � � � Southold,New lbrk 11971-0959 ZBA Fax(6+1)765-9064 Ruth D. Oliva( #t �a� 'Telephone(631)765-1809 Vincent Orlando http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD May 23, 2003 Fax and Regular Mail Lawrence C. Re, Esq. Munley Meade Nielsen & Re 36 North New York Avenue Huntington, NY 11743 Re: Appl. No. 5311 — Special Exception (AT&T, Fishers Island) Dear Mr. Re: Enclosed please find a copy of the Board's determination regarding the above application. The next step in the Town's zoning review-application process would he to continue with the Planning and Building Departments for approvals. You may want to furnish an extra copy of this determination to the other agencies if maps or other documentation are being filed. Thank you. Very truly yours, - L(nda Kowalski Enclosure Copy of Decision to: Building Department Planning Board 05/23/2003 15: 41 6317659064 ZONINGAPPEALSBOARD PAGE 02 APPEALS BOARD MEMBERS � gt,FFO(,�� Southold Town Hall Lydia A.Tortora,Chairwoman 53095 Main Road Gerard P. Goehringer so P.O. Box 1179 George Horning Oy Southold,New York 11971-0959 Ruth D. OlivaO� ZBA Fax(f31)765-9064 Vincent Orlando Telephone (631)765-1809 http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD RECEIVED 1�cf FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF MAY 15, 2003 MAY 2 2 2CC3 Appl. No. 5311 —AT&T WIRELESS (Our Lady of Grace Church) Property Location: Oriental Avenue, Fishers Island; Parcel 1000-9-7-11.1. Zone District: R-80 Residential. iovlhaldT.0Wn Clerk FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on May 1 F, 2003, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: PROPERTY FACTS/DESCRIPTION: The applicant's property contains 2.4+- acres, located along the north/east side of Oriental Avenue, distant 225.72 ft. east of Alpine Avenue. The property is improved with a Church, a two-story residence (rectory), and detached garage. APPLICANT'S REQUEST/BASIS OF APPLICATION: The Applicant, AT&T is a prospective tenant regarding land owned and occupied by Our Lady of Grace Church, proposing a personal communication service (PCS) facility and six panel antennas internally mounted within the steeple of the church building. There will also be associated equipment cabinetry within the basement of the church. Existing louvers in the steeple will be replaced with radio frequency (RF) transparent (stealth) material that will replicate the existing louvers. Antennas will be affixed to the interior of the upper steeple behind the stealth material. The Applicant is requesting a Special Exception under Article 100-162A.1 for the proposed installation of a Wireless Telecommunications Facility use, as shown on maps prepared by Neil Alexander MacDonald, R.A. issued 5/15/03. All parking and screening will be determined by the Southold Town Planning Board as provided under the Zoning Code site plan regulations. WIRELESS COMMUNICATION FACILITY DEFINED: Chapter 100 (Zoning) of the Town of Southold defines the applicant's proposed use under Section 100-162 as follows: Any unstaffed facility for the transmission and/or reception of wireless telecommunications services or other radio transmission and/or receiving service or use usually consisting of a wireless communication facility array, connection cables, an equipment facility and a support structure to obtain the necessary elevation. The support structure is either a building, telecommunication or radio antenna or tower or other approved structure. [Added 11-12-1997 by L.L. No. 26-1997; amended 2-2-1999 by L_L. No. 3-1999). 05/23/2003 15: 41 6317659064 ZONINGAPPEALSBOARD PAGE 03 Page 2-May 15,2003 Appl.No.5311 -AT&T Wireless 9-7-11.1 at Fishers Island CODE ARTICLE XVI: Section 100-160 of the Zoning Code allows wireless communication facilities, and particularly telecommunication towers, to be reviewed and approved in keeping with the town's existing zoning and historic development pattens, including the size and spacing of structures and open spaces. Furthermore, the standards herein r"flect two preferences: that wireless communication facilities are preferred in industrial areas and that wireless communication facilities be located on existing buildings and towers rather than on newly constructed towers- Any wireless communication facility must take into account the aesthetic aspects of the town, including open vistas, scenic byways and historic districts. In addition, the following provisions apply: § 100-161 . Scope. [Amended 12-8-1998 by L.L. No. 25-1998] The regulations of this article shall govern and control the erection, enlargement, expansion, alteration, operation, maintenance, relocation and removal of all wireless communication facilities. The regulations of this article relate to the location and design of these facilities,and shall be in addition to the provisions of the Southold Building and Zoning Codes and any other federal, state or local laws or Federal Communication Commission (FCC) regulations pertaining to such facilities. Nothing herein shall be construed to, apply to, prohibit, regulate or otherwise affect the erection, maintenance or utilization of antennas or support structures by those licensed by the Federal Communications Commission pursuant to Chapter 47 of the Code of Federal Regulations, Part 97, to operate amateur radio stations. § 100-162. Location of use. No wireless communication facility shall be used, erected or altered in the Town of Southold when located in an R-80 Residential Zorie District, except by (Planning Board) site plan approval, meeting the following requirements. (1) Wireless communication facilities on buildings shall require a special exception approval pursuant to this article. Wireless communication facilities on buildings shall be no higher than 10 feet above the average height of buildings (excluding signs, fences and walls) within 300 feet of the proposed facility. The building on which the wireless communication facility is located must be located at least 100 feet from the nearest property line and 300 feet from any landmark property or district listed by federal, state or town agencies. (2) Wireless communication facilities on existing telecommunications towers shall require a special exception approval pursuant to this chapter unless otherwise allowed by the terms of a prior special exception approval. (3) Wireless communication facilities on telecommunication towers shall require special exception approval pursuant to this article and shall not project higher than 10 feet above the average height of buildings (excluding signs, fences and walls)within 300 feet of the facility or, if there are no buildings within 300 feet, these facilities shall not project 05/23/2003 15:41 6317659064 ZONINGAPPEALSBOARD PAGE 04 Page 3—MaY 15,2003 Appl.No.5311 —AT&T Wireless 9.7.11.1 at Fishers Island higher than 10 feet above the average tree canopy height in that radius measured from ground level. If there are no buildings within 300 feet of the proposed facility site, all telecommunication towers shall be surrounded by dense tree growth to screen views of the facility in all directions. The base of the tower shall be located at least 100 feet from the nearest property line and 300 feet from a landmark property or district listed by federal, state or town agencies. (4) A wireless communication facility is a permitted use, not requiring site plan approval, if located on property owned, leased or otherwise controlled by state, federal or town government, provided that a license or lease authorizing such facility has been approved by that government. The height of such facility may be established by the public agency. (5) A wireless communication facility is a permitted use, not requiring site plan approval, if located on property owned, leased or otherwise controlled by a special district, provided that a license or lease authorizing such facility has been approved by the commissioners of the special district, and provided that It does not exceed the maximum heights specified above. Standards. In addition to the standards in Article XXVI of this Code, the Zoning Board of Appeals finds and determines the following: (1) The applicant is a public utility. (2) Construction of the proposed facility or modification of the existing facility is a public necessity, in that it is required to meet current or expected demands of the telecommunications provider and to render adequate service to the public. (3) The applicant has made substantial effort to locate or collocate on existing towers or, failing that, that the applicant has made substantial effort to locate on federal, state or town land and facilities. (4) The facility conforms with applicable FCC regulations. (5) There are compelling reasons, economic or otherwise, which make it more feasible to construct the proposed facilities than alternatives. OTHERCONSIDERATIONS: In addition to considerations under Article XXVI (Special Exceptions) of Chapter 100, the Zoning Board of Appeals has given consideration to the following in issuing a special exception approval for a wireless communication facility: 05/23/2003 15: 41 6317659064 ZONINGAPPEALSBOARD PAGE 05 Page 4-May 15,2003 Appl.No.5311 -AT&T Wireless 9-7-11.1 at Fishers Island (1) The height of the proposed structure/tower is the minimum necessary to render adequate service, inside the existing steeple of the church building. The antennas and equipment will not be visible from the exterior as proposed. (2) The antenna for the wireless communication facility is situated within a building and is minimized by its proximity and little or no visibility to residential structures, residential district boundaries and landmarks designated by town, federal or state agencies. (3) The wireless communication facility and its antenna(s) are designed and situated to be compatible with the nature of uses on adjacent and nearby property. (4) The wireless communication facility has been designed to use the surrounding topography to minimize its visual impacts. (5) The wireless communication facility has been designed to use the surrounding tree, building or foliage coverage to minimize its visual impacts. (6) The wireless communication facility maximizes design characteristics to reduce o~ eliminate visual impacts or obtrusiveness. (7) The applicant is a public utility. (8) Construction of the proposed facility, or modification of the existing facility, is a public necessity in that it is required to meet current or expected demands of the telecomrrun!cations provider and to render adequate service to the public. The applicant has established that the facility is necessary to fill in a gap in service for its established cellular telephone customer base, as well as allow for the overall expansion of the working range for their service in the eastern Long Island region, and, in particular, the community of Fishers Island, in the Town of Southold, New York. (9) The applicant has made substantial effort to locate or collocate on existing towers or, failing that, that the applicant has made substantial effort to locate on federal, state, or tows land and facilities. This effort is demonstrated by the applicant's Alternate Site Analysis of two other possible site locations in the vicinity of Fishers Island, including a pre-existing microwave facility currently maintained by AT&T Wireless, on the western end of the island, under a long term lease arrangement with the Fishers Island School District. (10) The facility conforms with applicable FCC regulations. (11) There are compelling reasons, economic or otherwise, which makes it more feasible to construct the proposed facilities, rather than alternatives. The use of an existing church bell steeple is cost effective to pursue, and insures that there will be no visible detrimental 05/23/2003 15:41 6317659064 ZONINGAPPEALSBOARD PAGE 06 Page 5—May 15,2003 AWL No.5311 —AT&T Wireless 9-7-11.1 at Fishers Island environmental impact, since the appearance of the steeple will remain the same, and the antennas will not be seen. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Horning, seconded by Chairwoman Tortora, and duly carried, to GRANT the Special Exception, as applied for and as shown on the site map prepared by Neil Alexander MacDonald, R.A. issued 5/15/03. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Tortora (Chairwomen), Goehringer, Horning and Orlando. (Absent was Member Oliva.) This Resolution was duly adopted (4-0). Ly ' A. Tortora. Ch irwoman 5/jZ1. 103 PLANNING BOARD MEMBERS OSVffU(�C BENNETT ORLOWSKI,UR.. P.O. Box 1179 Chairman =Q y� Town Hall, 53095 State Route 25 o Southold, New York 11971-0959 RICHARD CAGGIANO W Telephone (631) 765-1938 WILLIAM J.CREMERS O Fax(631) 765-3136 KENNETH L. ARDS MARTIN H.SIDOR PLANNING BOARD OFFICE TOWN OF SOUTHOLD February 11,2003 Mr. Lawrence C. Re Munley, Meade, Nielsen & Re 36 North New York Avenue Huntington, N. Y. 11743 RE: Our Lady of Grace Church, Fishers Island SCTM: 9-7-11.1 Zone: R-80 Proposed AT & T Wireless Antennas Dear Mr. Re: The Planning Board reviewed and approved your request for a Site Plan Waiver at its Work Session on Monday, February 10,2003. Inasmuch as the proposed antennas will be concealed within the Church building, and is similar to other antennas which have been approved in existing churchs, the Planning Board feels the Waiver is appropriate, since there will be no change in use or intensity on the site. Please contact this office if there are any further questions on this matter. Very Truly Yours, 1 0A1XV441Z Bennett Orlowski3O.0 Chairman Cc. M.Verity, Building Department /UXaQ _ 9_� _/.! TOWN OF SOUTHOLD PROPERTY RECORD CARDS /7- S OWNER STREET VILLAGE DIST. SUB. LOT FORMER OW ER E ACR. b _ /,�1M i e 1�Ve. .3 S ii W TYPE OF BUILDING ,ES. SEAS. VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS M t /V E 0 or h L I AGE BUIL NGC DITION NEW NORMAL B OAK-, &�B E i FARM Acre V lue P vlo ue r rillable 7 1 1 %r Tillable 2 -illable 3 Voodland ,wampland FRONTAGE ON WATER rushland FRONTAGE ON ROAD louse Plot DEPTH BULKHEAD 'otal DOCK TOWN OF SOUTHOLD ---------------------------------•-------------------------X In the Matter of the Application of OWNER'S AUTHORIZATION CELLULAR TELEPHONE COMPANY d/b/a AT&T Wireless Premises: Our Lady of Grace R.C. Church No Number Oriental Avenue Fishers Island,New York SCTM# 1000-9-7-11.1 -----------------------------------------------------------X STATE OF NEW YORK) ) SS.: COUNTY OF SUFFOLK)" ANDRZF7 WA<;2 GLCAI t2 being duly sworn, deposes and says: The undersigned holds title to the premises known as District 1000, Section 9,Block 7,Lot 11.1 (the"Premises"hereafter),and do hereby authorize Cellular Telephone Company d/b/a AT&T Wireless ("AT&T" hereafter) and its representatives to bring such applications for municipal approvals as may be necessary for constructing or installing on the Premises such antennas,support structures, and related equipment as AT&T may require for the establishment of its public utility wireless telecommunication facility. As such, I will fully cooperate with AT&T and its agents in obtaining any required Approvals. eov- (Owner's Si ature) Swom to b ore me this y o 02. NOTARY PUBLIC THO"116 F,p04"Y'Y lf1. Notary Publle State of New York No.46065W QUaiifi0o in Sutfolk county Term Expires 12131 ^ o�OgUFF0440 o o� G1k CIO : Town Hall,53095 Main Road • .F Fax(631)765-1823 Southold,New York 1 971-0959 Telephone(631)765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD January 22, 2003 Lawrence Re A/C Omnipoint 36 North New York Avenue Huntington, NY 11743 Dear Mr. Re: Enclosed, please find your application for a wireless communications tower at Our Lady of Grace Church, Oriental Avenue, Fisher's Island, Suffolk County Tax Map # 1000-9-7- 11.1. I have determined that you do not need a Notice of Disapproval from this office. Please be aware, however, that you will still have to file an application with The Southold Town Zoning Board of Appeals for a special exception. If you have any questions about this matter, please call me at 631-765-1802. ZRespe I + Damon Peter Rallis Building Permits Examiner CC: File 05/26/2004 10:57 FAX 631 788 7798 FITELEP113NE 001 W2620 PysbM Island UMdy CO. Drawer E 3%hers Island, NY 06390 631788 7251 Dates� ep FAX#.� From: / Fax#631788 7798 Subject Number of pates including tbis one 05/26/2004 10:57 FAX 631788 7798 FITELEFHONE IM002 ou BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ NAL [ ] FIREPLACE & CHIMNEY REMARKS: 67• x ° DATE INSPECTOR 1� 05/26/2004 10:57 FAX 631 788 7798 FITELCPHONE 0 003 FIELD hQSPEC1Z04�S REP.QBT DATE COMMENTS . Ate�.++ 5 FUVNDATION(151) A - ^y - c FOUNDATION(2ND) OC 2 c 'ROUGH FBAMA!iG R pmy P`LVMSiLVG � INSOLATION Y8R N.Y'. � STA2Z 7A*rJ 'QGY CODA MNAL ADDMONAL COMMENTS O m _ m y O r_+ BUAKD OF HEALTH . . . . . . . . . . . . . . . FORM NO. 1 3 SETS OF PLANS . . . . . . . . . . . . . . . TOWN OF SOUTHOLD SURVEY . . . . . . . . . . . . . . . . . . . . ... . . BUILDING DEPARTMENT CHECK . . . . . . . . . . . . . . . . . . . . . . . . . TOWN HALL SEPTIC FORM . . .. . . . . . . . . . . . . . . . SOUTHOLD, N.Y. 11971 TEL: 765-1802 NOTIFY: hi CALL . . . . . . . . . . . . . . . . . . Examined........ 19:... ) 1f MAIL TO: . . . . . . . . . . . . . . . . . . . . Approved....... �. LC.., 19.Z.°e�Permit No. ! �� ... Disapproveda/c ............................. .. .................................... ....................................... .. .......... (Building Inspector) 7 9n") APPLICATION FOR BUILDING PERMIT --' Date. . . . . . . . . . . . . . . . . 19. . . . INSTRUCTIONS a. this application must be completely filled in by typewriter or in ink and submitted to the Building Inspector writ 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this application. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Wilding Inspector will issue a Building Permit to the applicant. Such permit shall be.kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy shall have been granted by-the Building Inspector. APPLICATION IS tERERY MAIE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Tam of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for time construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to c6mply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in buildingfor necessary, inspections. Cell e(Mailing Company d/b/a AT&T Wireless By . ................................ Ilicant, or name, if a corporation) �S eekP.arks.Drive,Woodbury,.V.11-797 SFSkw.�q�c�l h� ress of applicant) pm fM syr State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Lessee ..........................................................................................................."............ Our Lady of Grace R.C. Church Nameof awner,of premises ............................ .................................... ....... ........ .._. ........... (as on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer. ......................................................... (Nave and title of corporate officer) Builders License No. ......................... . Plumbers License No. Electricians License N?_ ........... Other Trade's License No. .................... 1. Iocation of land on which Cur. Lad of urace R.C. Church proposedwork cell be done...........Y.................................................. No Number Oriental Avenue Fishers Island, New York 11957 ................................................................................................................"...... House Naber Street Hamlet Canty Tax Map No. 1000 Section .....9.......... Block .....Z......... Lot ... 11:1........ Subdivision ...................................... Filed Map No. ............... Lot ............... (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ...GbIkub................................................................... b. Intended use and occupancy �nmdnR@d.P.U41J.G.uti]j.f.Y.fireless..tol�communi�atian.facili.ty... consisting of antennas affixed to inside of church steeple and related equipment cabinets installed in church basement. Nature of work (check which applicable): New Building .......... Addition It-pair ....... Removal ••.. Alteration ....... ... ..... ............. Demolition ............ ottherWorklnStdJ1.RU41i.G.Ut711tY.wirglests, (Description etecommuins7deon $120,000.00 Estimated Cost ......................... fee ............ church steeple.................................. (to be paid on filing this application) If dwelling, number of dwelling units ..N/A...... dumber of dwelling units on each floor N/A Ifgara a. number of cars N/A 8 If business, commercial or mixed occupancy, specify nature and extent of each typeof use..Pr.....oposed Public UtilitY ............... Dimensions of existing structures, if any: *Front................ Rear Dept * ee Plans Submitted Herewitfi.** Depth ."""""""" Neigiht idunbec of tories ........ Dimensions of same structure with alterations or additionsi Front ....... Depth ........ Rear ............... P ...........•........ Neigtht .................... Number of Stories . ............... Dihrensions of entire new construction: Front Rear ............... Depth .............. lleight ......................... Number of Stories . ..................... Size of lot: [Font .................... Rear ..... Deed dated December 27, 1956'**'*** "" Depth:r.......,..... ). Date of Purchase Recorded.1/14/51.. Nane of Former Owner West End Land Company, Inc. ............................. �. Zone or use district in which premises are situated R;80, Residential Low Density .......................... ?. Does proposed construction violate any zoning law, ordinance or regulation: ........................ 3. Will lot be regraded ...N(({,,,,.....,,, Will excess fill be removed from eahisea: YES Our Lady of Grace Church Ori�ntal Ay�yenue NO i. Names of Rorer of premises ....... Address FJS erS.1S.I.dO ,..NY........ Phone No. Name of Architect Wi l l i am F. Collins.,._AIA Address etau a hn o i ve ( """"' TT �It pp 6... Kr; �Y.� 7.f,........ Phone No.6JA-8.4.50.... Name of contractor _ Vantd�e 15 N. Mill St. ........................ Address Nyack,.NY.]0960.............Phone No. i. Is this property within 300 feet of a tidal wetland? * YES .......... *IF YES, SUMUD 1D{dt T[a1S1W PMUT HU HR 1ZC ABED. NO .......... PLOT DIAGRAM locate clearly and distinctly all buildings, whether existing or proposed, and indicate all set-back dimensions nom property fires. Give street and block number or,description according to deed, and show street names and indicate hether interior or corner lot. See Plans. PAPE or Nld Y(W, )l1NlY Or . SW 2�,� ..................being duly sworn, deposes and says that be _3r the applicant indir'.tol signing contract:) xrve nmmed, is the ....Agent for Owner ..... ...... .... .... ...... . ..... (Contractor,. .....i agent,. . . corporate officer, etc.)........................................... f said owner or owners, and is duly authorized to perform or have performed the said work and to make aril file this pplicatioh; that all statements contained in this application are true to the best of his knowledge and belief; and hat the work will be performed in the manner set forth in the application filed therewith. worn to before me this m' ........2- ...:day of .. .\?"?nN1 `I� �P t?�— ' Cellular Telephone Company Notary Public d/ /a AT& Wireless .. .. Notary """""""""""' Public,State o/Ne No. 52.4799664 rYYorlt (Si ture of Applicant) uffolk Comm shoran Expires May 3 � f r 3 _ tl.+ h �¢v�I�PWLtir�'t" MMnayv BUILDING PERMIT EXAMNER CHECK LIST DATE RENEWED: /03 APPLICANT: C. 'DATE SUBMITTED:�5-,Qa/03 SCTM# DISTRICT: 1,000, SECTION: ,BLOCK: �, LOT: SUBDIVISION: ADDRESS g t Lff�CITY`--J�- �.ZONINGDISTRIM _CONFORMING? BUILDING PERMITS OPEN/EXPIRED- BP -Z/C/0 Z- , INFO /BP -Z/C/0 Z- , INFO BP -Z/C/o Z- , INFO /BP -Z/C/0 Z- , INFO PRE CO: Y OR N BP -Z/C/0 Z- , SINGLE & SEPARATE CERTIFICATION-REQUIRED n(o NOTES: LATS 40,000SF-100-24.Lot recogni tion.(CREATED before June 30,1983),UNDERSIZED -25.Merger.(A nonconforming at any time after 7/1/, REQ. LOT SIZE: ACT. LOT SIZE: Q. LOT COV. ACT. LOT COV. REQ. FRONT PROP. FRONT REQ SIDE ACT. SIDE REQREAR PROP. REAR REQ. HEIGHT PROP. HEIGHT PROJECT DESCRIPTION: r ` ESTIMATED PROJECT COST: ARCHITEC E ^LvnJV FAST TRACK _ WATERFRONT? A(lo DESCRIPTION: PANEL #: FLOOD ZONE: , COMPLIANCE: APPROVALS REQUIRED SUFFOLK COUNTY HEALTH D T: YES or tl2jBED#): DTE: _/ /_ PERMIT#: TOWN SEPTIC RECEIPT: Y or NEW YORK STATE DEC: PRE-D 9n/75 YES o 0 SOUTHOLD TOWN TRUSTEES: S o 0 TOWN ZONING BOARD APPROV r NO TOWN PLAN. BOARD APPROVAL• . r I 1 TOWN HISTORICAL PRE (SPLIA): YES or60 NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2) S or NO NOTES: FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR: SF SECOND FLOOR: SF OTHER: SF INIT OTHER TOTAL TOTAL: SF FEE FEE FEE 1. ( —SF)- ( SF)= SFX $ =$ +$ +$ = $ 2. ( SF)- (---SF)= SF X $ =$ +$ +$ = $ 3. C_SF)- ( —SF)= SFX $ =$ +$ +$ = $ FINAL TOTAL: $ 1 NEW YORK STATE CODE COMPLL ,NCE CHECKLIST USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: HEADERS: Y/N WALL STUDS: Y/N GIRDERS: Y/N CEILING JOISTS: Y/N FLOOR JOISTS: Y/N ROOF RAFTERS: Y/N LUMBER SPECIES AND GRADE: Y/N DESIGN LOAD CALCULATIONS: Y/N SHOULD INCLUDE LIVE,DEAD,SNOW,SEISMIC AND WIND(INCLUDING UPLIFT AND EXPOSURE) WINDOW AND DOOR SCHEDULE: MISSLE TEST REQUIREMENTS: Y/N EGRESS, LIGHT, VENT: Y/N LOAD PATHS: Y/N ROOF TO FOUNDATION NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) VEDAS N�OTgE�D�7 B.P.I FEE: NOTES: /- NOTIFY BUILDING DEPARTMENT AT 765-1802 SAM TO 4 PM FOR THE 1 . THE FOLLOWING IS A PARTIAL LISTING OF ZONING DESCRIPTIONS OF THEFOLLOWING�j-FOUNDATION - TWO REOUIRED TOWN OF SOUTHOLD: FOR PGURED CONCRETE_ WITH PLYORK STATE & TOWN CODES R-40 RESD NTIAUSLOW DENSITY AA MINESS o�TgUk �eNUe 3.4. FNALATIONCON NST1R `UCTI W �4 REQUIRED ANDCONDITIONS OF R-80 RESIDENTIAL LOW DENSITY A BE COMPLETE FOR C.O. � `7/2 3 �3 $OUTHOLD TOWN ZEA ALL NETO CORIICTION $HALL ME �(F $OUTHOLDTOWNPIANNINOBOARD REO UIREMENT$ OF THCOpE$QFN E N O AX LOT. OT DESSIGN OR CONSTRUCTION ERR II ` SOUIHOLD TOWN TRUSTEES NOTE: Oa°'1°- S.DEC INFORMATION SHOWN HEREIN IS BASED UPON A SURVEY PREPARED BY: BARRETT, B BONACCI & VAN WEELE, P.C. CIVIL/ENGINEERS/SURVEYORS/PLANNERS, 175A TAN °T OQ/ ab"-0`5',11 TAX LOT T COMMERCE DRIVE HAUPPAUGE, N.Y. 11788 (631 ) z-35-1022 (ON DECEMBER 27,2002 PROJECT NO: A021059 Q �COR TAX L°T '°° ° OCCUPANTA} LOT I°°°-+°-e-e TAX L°T USE IS U FUL 1°°°-1°-e-s °os eLOT1° WITHOUT CERTIFICAT R - 4 0 OT °°°;o_ o^; OCC PANSY 100' RADIUS LIST OF OWNERS: ADDITIONAL OWNERS WITHIN 300': a -eTAX 1°.3 1°00 LOT *1 , 1000-009-07-011 . 1 9. 1000-009-07-009 011 . 1000-009-04-022.02 11 . 1000-010-08-002 & 004 n e 0 LOTAXl;°a_e OUR LADY OF GRACE RC CHURCH TIMOTHY W LAUGHLIN JOAN CHAVES EDMUND C & MARGARET HEDGE / u T. 2_ + P 0 BOX 425 19142 EAST HINSDALE AVENUE 5 CARYN LANE P 0 BOX 297 GLNMAINE AVENUE ° 102 OD ZD FISHERS ISLAND NY 06390 AURORA CO 80016 WEATOGUE CT 06089 FISHERS ISLAND NY 06390 J� /' ALPINE qVE [dV USE: CHURCH USE: RESIDENCE USE: RESIDENCE USE: RESIDENCE / _ / •' ,' '•C ' .... •� NUE @ M�6r Wlfikl HAPTER 46 . . . . . . . . . . . . . . 2. 1000-009-04-023 2. 1000-010-08-003 °r l' '.'.'.'.'.'.'.'.'.'.'.'.'�'.' '.'.'.' ' '.'.'.'.' UNDERWRITERSCERTIFICA E §®dfkl®6H TOWN 0®®E, I °°°-°-e-,e, / � � . . . . . .�.� . . . . . . ` o°d-„ REQUIRED 2. 1000-010-08-010.01 *10. 1000-009-07-009.02 SHILLO THOMAS JOHN C & VIRGINIA BEGGS I RAYMOND A & ELIZABETH M YAKAITIS ALBERT H GORDON P 0 BOX 161 P 0 BOX 646 P 0 BOX 623 AL GRACIE SQUARE 4.'.'.'.'.'. ' . .'. .' HATCHED AREA IN ICATES FISHERS ISLAND NY 06390 NEW YORK NY 10028 FISHERS ISLAND NY 06390 FISHERS ISLAND NY 06390 pyPIN E • • • • • • SUBJECT PROPER FOR USE: RESIDENCE USE: VACANT USE: RESIDENCE USE: RESIDENCE VENUE ' ' 000As �rili ` " 'a SITE PLAN SEE D TAIL 1 , ORI TAL A . . . . . . . . ..'.'.'.'.` SHEET SP-2 3. 1000-010-08-010.02 *1 1 . 1000-009-07-010 3. 1000-009-05-009 13. 1000-010-08-005 • • • • • • • • • • • • • • • • • • • • •� AU STRUOTIONSHALL MARY GORDON ROBERTS ODIE & MARY K STRYNK °r f +°°°-•-J-+° THEREOUIREMENTSOFTHE MORTON L KENYON FISH -RS ISLAND LIBRARY 10 GRACIE SQUARE P 0 BOX 143 I I ' ' ' ' O P 0 BOX 366 III LOT .'.'.'.'.'.'. M COL�ESOFNEWYORKSTATE. c/o BETH CONNOLLY NEW YORK NY 10028 FISHERS ISLAND NY 06390 E-I T". L°T �,°�-e_,-1,r � • • • 19 FRANKLIN STREET FISHCRS ISLAND NY 06390 USE: RESIDENCE USE: RESIDENCE 00 . . . . . .'.'l'. .'. . NEW LONDON CT 06320 USE: LIBRARY o . . . . . • . • . . . .,• . •� USE: RESIDENCE 4. 1000-009-05-011 .011 14. 1000-010-08-006 & 007 0 RiF� *12. 1000-09-12-007.01 246 M INC ANDREW J & SUSAN AQUILA I pp / 4. 1000-010-08-010.03 MARGARET M BOGERT 26 HIGH WOOD ROAD & DOROTHY MANNETTIu r"><°L°'r" ' JF E "`""" ' JOHN H & DEBORAH A DOUCETTE EAST 66TH STREET BLOOMFIELD CT 06002 223 AVERY HILL ROAD P� O \ "N°LOi 16l R - 80 P 0 BOX 77 NEW YORK NY 10021 USE: HOTEL LEDYARD CT 06339 a FISHERS ISLAND NY 06390 USE: RESIDENCE USE: RESIDENCE AuLOr USE: RESIDENCE 5. 1000-009-05-012 AV U�•• DAI LOTI-IIAN r° e • MARY GORDON ROBERTS 5. 1000-010-08-009 ORIENTAL AVENUE 5. 1000-010-08-011 10 GRACIE SQUARE ALEXANDER K & ELLEN R TAYLOR JOHN C GOSS NEW YORK NY 10028 3425 OVERBROOK LANE USE: RESIDENCE N WALTER STREET \ NEWTON MA 02459 / HOUSTON TX 77027 Z °r USE: RESIDENCE � �°°°-°_J-e.z �� USE: RESIDENCE 6. 1000-009-07-007 .Ax 2-71V TAM LOT 1°°°_,_I 100°-9-J-J / JOHN R & BARBARA (C KIMBERLY 7 6. 100-010-08-012 9225 GERMANTOWN AVENUE 16. 1000-010-08-013 FRANCIS KERNAN JR PHILADELPHIA PA 19118 ROBERT E & EG WALL c/o INDELLI & COMPANY USE: RESIDENCE P 0 BOX 595 \ \ u69 / 5 OLD ROAD FISHERS ISLAND NY 06390 ELMSFORD NY 10523 7. 1000-009-12-006.011 USE: RESIDENCE USE: RESIDENCE JOHN W METTLER III \ w CORNELIA DALEY / *7. 1000-009-05-016.01 950 3RD AVENUETAM L°T ST JOHNS EPISCOPAL CHURCH NEW YORK NY 10022 \ \ 1O°°-° o�"-e O el / FISHERS ISLAND NY 06390 USE: RESIDENCE USE: CHURCH 8, 1000-009-05-017 8. 1000-09-12-008.01 \ / HAY HARBOR CLUB INC 10 BOXX 195 GLEN J NORTON P O BOX 477 FISHERS ISLAND NY 06390 FISHERS ISLAND NY 06390 NPL w USE: RESIDENCE USE: GOLF COURSE * DESIGNATED AS LANDMARKS PER TOWN OF SCUTHOLD 9. 1000-010-08-001 .01 Y HENRY H & LYNNE G FISHER O 712 MOUNTAIN ROAD w WEST HARTFORD CT 06117 USE: RESIDENCE tN 10. 1000-010-08-001 .02 HENRY LUCE III 720 5TH AVENUE SUITE 1500 NOTE: NEW YORK NY 10019 USE: RESIDENCE IF THIS SHEET X 17", REFER KETO ADJACENT GRAPHIC so' zoa Y MAP CALE, NORTH 1"=100'-0" _ Q -_.__ FC PROJECT NO Racy 02-4926 AT&T WIRELESS SERVICES FISHERS ISLAND AT&T WILLIAM F. COLLINS, AIA 903 006 201 v o � � � ' ;', �� �* SITE PLAN AND NOTES - A R C H I T E C T S, L L P Q 1/11/03 ISSUED FOR FILING PL, JM aE ' , ORIENTAL AVENUE AT&T WIRELESS SERVICES, INC. 10.1 TECHNOLOGY DRM SETAUKET,NY117;3 FISHERS ISLAND, NY 11957 NO. DATE REVISIONS By CHK APP'D u e JOB NO. SITE N0. DRAWING NUMBER REV VOICE: 631-689.8450 FAX: 631-689.8451' 16 PARAMUS, NJ 007652 UE SCALE: AS NOTED DESIGNED DRAWN: PL 24445 903006201 903 006 201 SP- 1 A NOTES: 1 , ELEVATIONS SHOWN HEREIN ARE IN AN ASSUMED DATUM. d� AQP/l�Fq � 2. PROPERTY LINES SHOWN FOR FORMER TAX LOT 16 ARE BASED UPON TAX MAP, DIMENSIONS ARE THEREFORE APPROXIMATE. THE EASTERLY LINE OF FORMER TAX LOT 16, AS SHOWN WAS HELD PARALLEL WITH THE EASTERLY LINE OF FORMER TAX LOT 11 , AS PER L.8499, P. 467. 0 s 36'°1'ao" E 3. THIS SURVEY WAS PREPARED FOR A SPECIFIC PURPOSE AND IS NOT INTENDED TO BE USED FOR A TRANSFER OF TITLE OR ANY OTHER FINANCIAL PURPOSE. Q 25 � (SEE NOTE J� 4U.6 NOTE: ,�(/� ro ]61 449 INFORMATION SHOWN HEREIN IS BASED UPON A SURVEY PREPARED BY: BARRETT, s, 4 BONACCI & VAN WEFLE, P.C. CIVIL/ENGINEERS/';URVEYORS/PLANNERS, IL75A COMMERCE DRIVE HAUPPAUGE, N.Y. 11788 (631 ) 435- 1022 (ON DECEMBER `° I o P 27,2002 PROJECT NO: A021059 `Q JI 106 4-5 W 5 G RACE �, 2a 0 61 STOR ,� I / ,U .56 NOTE: O 5]2 092 FOR KEY PLAN SHOWING ADJOINING LAND USES, STRUCTURES, ZONING LANDMARK 55,5 AND OWNERSHIP WITHIN 300' SEE DETAIL 1 , SHEET SP- 1 aa,5 o y STOR'y a ON 1 _ 44 o (ftE510ENGE) p5 6 D„ T x LOT 1000-10-8-11 NOTE: N 5 25.000 / ° .2 LOT COVERAGE = 10% 1 Q R (NO CHANGE) 44.2 O sa LANDSCAPE COVERAGE = 88% (NO CHANGE) TAX LOT 1000-9-7-10 h 1 4L7 DO 1 - 7- 1 . 5 4 R as J9.G I 1 21 I 46 R >T 7 I I PjE LU 1 O R L Y a e 5 RGGE GER W000 IB.1 I v 44B �/ T PORCH pV� X /� LO RT & GRAVEL ARKING AREA 4e'6 .10 0 7- 11 ) e I EXISTING CHURCH BUILDING 2 a5 4 J5. �Qf LL B 4G 5 2 R R C) FRAME9. 1 STORY I Z V BUILDING 40.4 . 1_i (CHURCH) a 1 W 41 ] a ` 208SHADED AREA INDICATES NEW EQUIPMENT ROOM oG� 4 � LOCATED IN CHURCH BASEMENT AND STEEPLE P PI CONTAINING ANTENNAS ABOVE ^ 1R 'R� ' 5 B' 59'm' V 'A 1Oy99, l� 3 444 247' .. ]]9 461 46.J I �I 1 e R TAX Lor loon—to—a—lz roR 4 'Qf� I 1 I III O � , OUR LPC \ GRACE 6,5 CHH URCH WORSHIP SCHEDULE I� Q N 3 109 (F M RL F/I/G 61 s X 1 EXISTING CHURCH SIGN, SEE ELEVATION BELOW F SIGN ELEVATION N T.S, v 375 I 9 I 1 Jv I /V 2g.18 15 5 Ja a 2 \ I TN sEE O . \° NOTE: IF THIS SHEET IS 11 " X 17", ENLARGED SITE PLAN REFER TO ADJACENT GRAPHIC 0' 15' 30' Bo' SCALE: i" = 30'-0" S.0 T.M DISTRICT 1000 — SECTION 9 — BLOCK ] — LOT 11.1 SCALE. NORTH Q FC PROJECT NO _ �To A 02-4926 AT&T WIRELESS SERVICES FISHERS ISLAND _ AT&T WILLIAM F. COLLINS, AIA. 90.3 '2 ��s0') _ A R C H I T E C T S, L L F' ENLARGED SITE PLAN AND NOTES ORIENTAL AVENUE Q 1/17/W ISSUED FOR PILING PL, JM AE n ;' _ .' �, ,ir 10.1 TECHNOLOGY DRIVE SErA[1IAT&T WIRELESS SERVICES, INC. - " - VOICE: 631fi89-8450 FAR: 631-689-8459 FISHERSISLAND, NY 11957 15 EAST MIDLAND AVENUE No, DATE REVISIONS By CHK APP'D 226 ��1 ' JOB NO. SITE NO DRAWING NUMBER REV PARAMOS, NJ 07652 SCALE. AS NOTED DESIGNED PRAWN: PL \-Up �I�� � %� 24445 903006201 903 006 201 SP-2 A NEW 200 AMP "APPLETON" EXISTING ELECTRICAL METER GENERATOR RECEPTACLE AT MOUNTED TO EXTERIOR GRADE ABOVE EXISTING LOUVERS TO BE REPLACED FACADE OF BUILDING AT BIG 1 4" NEW AT&T 200 AMP 1 2 WITH NEW RF TRANSPARENT LOUVER GRADE / POWER PANEL NQ7',,�V PANELS, TYP. OF (3) LOCATIONS AT NEW 200 AMP AT&T �__ UPPER STEEPLE DISCONNECT MOUNTED EXISTING ELECTRICAL PANEL BELOW NEW SUB-METER AND PLYWOOD BACKBOARD EXISTING SMOKE DETECTOR SECTOR "B" ANTENNAS MOUNTED NEW AT&T SUB-METER TO BE REMOVED AND 2 BEHIND NEW RF TRANSPARENT LOUVER REPLACED WITH NEW P— P— �— _.._. _ _. PANELS, TYP. OF ALL SECTORS NEW COAXIAL ANTENNA - CABLES ROUTED ON SMOKE DETECTOR I FUTURE 36'-4"f A.G.L. P UNISTRUT UP THROUGH w PTMA \ FRAME TO BEXISTING OERAND REMOVEEDOAND 84 'h -4"f A.'kS L. FLOORS TO STEEPLE � L RAD. CL OF ANTENNA ABOVE N KAE F> REPLACED IDOOR TH EAND -0 EXISTING CEILING SYSTEM PET ASITEI FRAME, TYP. 31 '-0"f A. .L. TO BE REMOVED AND LCA INET REPLACED WITH NEW DASHED LINES INDICATE SECTION X79'-0"f A.l"f A.I �.S.L. 1 1 2" HR. FIRE RATED OF EXISTING DOOR JAMB, WALL FLOr OR OF ZIPPER STEEPLE — CEILING AND DOOR TO BE REMOVED _ NEW THROUGH WALL -- EXISTING WOOD PLANK FLOORING 9'-8"f A.( ',.L. EXHAUST FAN TO TO BE REMOVED. SEE NOTE THIS ' t L. = REPLACE EXISTING DETAIL X67'-8A.1A.( ;,L. ­FLOOR_ OF LOWER r — WINDOW AND FRAME NEW 48"x48" TELCO STEEPLELBACKBOARD _ NEW COAXIAL ANTENNA CABLE ------------ DASHED LINE INDICATES -- ROUTED ON UNISTRUT UP THR )UGHEXISTING CHURCH ORGAN 1 NEW 3'-0" LOUVERED PUMP TO BE RELOCATED P_ FLOORS FROM NEW AT&T EQUIROOM IN BASEMENT TO UPPER MENT DOOR i WITHIN ROOM IF NECESSARY i � STEEPLE ANTENNAS ABOVE- 1 '-7"t A.C .L. REMOVE EXISTING ALUMINUM r STORE 49'-7"t AM.S.L. SCREEN DOOR I � 2" NEW FULL HEIGHT 2 HR. TO EQUIP. _ TEXISTING STORM DRAIN TO BE t i' 1 '-4' FIRE-RATED ROOM CLG, CLEARED OF DEBRI AND To SHAFT WALL, TYP. 0'-0"1 BE MADE FUNCTIONAL I! "n 48'-0' f A M.S.L. EXISTING STAIRS TO DASHED LINES INDICATE SECTION GRr ADE EXTERIOR GRADE FROM NEW AT&T EQUIPMENT OF EXISTING DOOR JAMB, WALL ROOM AND DOOR TO BE REMOVED, TYP. EXISTING HAND -6'-2"± E ,G.L. BELOW GRADE ENTRANCE TO RAILING 41 '- 10"t"t A.M.S.L. NEW AT&T EQUIPMENT ROOM EQY UIP. ROC M F.F.E. IN BASEMENT ,,6, CONTRACTOR TO REMOVE EXISTING WOOD FLOORING SYSTEM DOWN TO EXISTING CONCRETE SLAB. EXISTING k CONCRETE SLAB TO BE PATCHED, REPAIRED AND NOTE: MADE LEVEL PRIOR TO PLACEMENT OF NEW VINYL IF THIS SHEET IS 11 X 17", COMPOSITE TILE FLOORING. REFER TO ADJACENT GRAPHIC SCALE. NORTH/EAST ELEVATION f� ENLARGED BASEMENT EQUIPMENT PLAN 1,33' 2.66' 533' NORTH 1 SCALE 1/8" = 1' 3/8"-Y FC PROJECT NO FISHERS ISLAND AT&T4 ,y 02-4926 AT&T WIRELESS SERVICES WILLIAM F. COLLINS, AIA 903 006 2010 ARC R I T E C T S, L I, P ELEVATION AND DETAILS ORIENTAL AVENUE Q 1/17/03 ISSUED FOR FILING FE, JM AE O1 10-1 THCHNOfAOY DRIVE BETAOKET,NY 111!)3 FISHERS ISLAND, NY 11957 15 EAST MIDLAND AVENUE AT&T WIRELESS SERVICES, INC. No, DATE REVISIONS BY CHK APP'o ��E Or t^ -iJOB N0. SITE N0, DRAWING NUMBER REV VO7C8: 631699-8450 FAR: 631.689-9450 PARAMUS, NJ 07652 SCALE As NOTED DESIGNED DRAWN: PE 24445 903006201 903 006 201 SP-3 A • NEW COAXIAL ANTENNA NEW SECTOR "A" LINE OF NEW COAXIAL ANTENNA1 _l CABLES ROUTED UP ON ANTENNA EXISTROOFINGS GABLE CABLES ROUTED UP UNISTRUT THROUGH EXISTING HORN, TYP. THROUGH CEILING ON o EXISTING FIRST FLOOR EXISTING EXISTING LOUVERS TO BE UNISTRUT TO EXISTING STORAGE ROOM CEILING STORAGE ROOM REPLACED WITH RF FIRST FLOOR STORAGE rFuroR < EXISTING NEW COAXIAL NEW AT&T AND LOWER STEEPLE TRANSPARENT LOUVER ROOM ABOVE iWGOdAI /—EQUIPMENT AREA ABOVE SANCTUARY ANTENNA CABLES — , uTuaE ROUTED UP FROM // PANELS, TYP. OF (3). I INKA ✓% ._ _ ROOM O AREA LOWER STEEPLE /j SEE DETAIL 2, THIS �LTRASWRNe, l %,. SHEET _ s _ BELOW ON UNISTRUT r j TO NEW AT&T � . . 'Il /, ' ' NEW LAND LINK 3 EXISTING STATUES, j ANTENNAS MOUNTED ( PARABOLIC ANTENNA �— EXISTING �� EXISTING UPPTO ER IDE FACE STEEPLE OF CONTRACTOR TO RELOCATE EXITING TYP. OF (3) Cr HORN TO ACCOMMODATE POSITIONING THRIFT WORSHIP STORE AREA OF NEW PARABOLIC ANTENNA �� If� ,� —�_ NEW SECTOR —_ LIL EXISTING ACCESS ANTENNAS CONTRACTOR TO PROVIDE CONTINUOS 2x6 WD. HATCH TO STEEPLE �' �L BRIDGING BETWEEN FLOOR JOISTS WITHIN HATCHED ABOVE DASHED LINE INDICATES , AREA, AND SOLID BLOCKING AT BEARING POINTS. EXISTING WOOD PATCH ROOFING MEMBRANE AS REO'D FRAMING MOUNTED Q FROM CEILING ABOVE---/ LINE INDICATES HIGH POINT IN NEW SECTOR "B" SLOPED FLOOR ANTENNAS z EXISTING ACCESS HATCH TO LOWER EXISTING STAIRS ' EXISTING STAIRS STEEPLE BELOW FROM BASEMENT FROM BASEMENT LINE OF k EXISTING GABLE ROOF BELOW BASEMENT PLAN FIRST FLOOR PLAN UPPER STEEPLE PLAN ANTENNA CABLE ROUTING PLANS NOTE: ° 2 4 s NORTH 1 SCALE: 1 4 = 1 -o IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. 1/4"=1'-0'- NEW /4"=1,-0'- NEW 7"x4"X3/8" NOTES: GALVANIZED STEEL RIGGERS TO DELIVER ANTENNA THROUGH LOUVER ANGLE, TYP. SECURED ROUGH OPENING AT TIME OF LOUVER REPLACEMENT. 9 1 /4" WITH 3/8" LAG BOLTS, 10'-6" _ 5 -0' BOL- AT EACH EXISITNG 1 '-11 1 /4" 2'_0" 2'-7 1 /2" 2'-0" 1 '-11 1 /4" 2'- 10" NEW "S6" TRIPOD, 1 '-5" 2'-0" 1. STUU LOCATION WHERE 6 6 "MICROFLECT" A OCC JRS PART#91013 NEW 3"x3"X1 /4" ° c� ° GAL\ ANIZED STEEL ANGLE SECURED TO B 7"x4 "x3/8" ANGLE WITH 1 '_6" 1 '-6" 1 /4" CONTINUOUS WELD, V.LF NEW LAND LINK V.I.F TYP PARABOLIC ANTENNA, GALVANIZED "ANDREW" STEEL U-BOLT, TYP. _ PART#P35-52 STEEL i NEW PANEL ANTENNA,---__. _� SEE DET. 1 /E-5 \_ EXISTING WOOD FRAMING 1 9 _�, ll---_— N ' 4 fl: n MOUNTED FROM CEILING. EXISTING HORN, TYP. OF (4' HORN NOT SHOWN FOR EXISTING WOOD FRAMING, o REASONS OF CLARITY u TYP., V.I.F. NEW RF TRANSPARENT r B LOUVER PANELS, TYP. NEW 2-3/8" O.D. OF (3), SEE NOTE GALVANIZED STEEL PIPE, THIS DETAIL TYP, 5/8" DIA. COAXIAL NEW RF TRANSPARENT 1 '-3" ANTENNA CABLE TOUTED LOUVER PANELS, TYP. ON UNISTRUT ALONG OF (3), SEE NOTE THIS " sss INTERIOR WALL OF DETAIL CD UPPER STEEPLE, TYP. I IIIBOLT AT EACH EXISITNG 7/8"0 COAXIAL ANTENNA _ STUD LOCATION WHERE ° ° 71 CABLES ROUTED ON ° ° ° ° ° ° OCCURS ° UNISTRUT ALONG 555 ° INTERIOR WALL OF � ° ° 7/7UPPER STEEPLE, TYP. ---------_-i_ BOLT AT EACH EXISITNG A 6'- 10" CONTRACTOR TO PROVIDE 5'-3" A 4'- 10" STUD LOCATION WHERE R.O., YP. NECESSARY SHIMS A TYPICAL SECTION OCCURS AN AL SECTION TO MAKE NEW "s6" r. TYPICAL ELEVATION NOTES: NOTES:ANTENNA MOUNTING DETAILS BTYPICALELEVATION CONTRACTOR RESPONSIBLE INSTALLATION FOR PARABOLIC ANTENNA TRIPOD PMOUNTING DETAIL ANTENNANMOUNTNGEDDETAIL, 2 SCALE: 3 4" = V-0" OF RF TRANSPARENT PANELS. 3 SCALE: 3/4" = V-0" SEE DETAIL 2 THIS SHEET. Q� Q _ FC PROJECT NO FISHERS ISLAND _ AT&T �flcO ` 02-4926 AT&T WIRELESS SERVICES Q I� ,DER yiT WILLIAM F. COLLINS, AIA 903 006 201 / wPa F� QB 5/15/OJ ISSUED FOR ZONING AgJ1A AF TI ARCHITECTURAL DETAILS -- A R C H I T E C T S, L L P ORIENTAL AVENUE Q 10/30/02 ISSUED FOR REVIEW PL AF 7 AT&T WIRELESS SERVICES, INC. 10.1 TCCE 40LOGYDRM SETAUKET,NY11733 FISHERS ISLAND, NY 11957 15 EAST MIDLAND AVENUE NO DATE REMSIONS BY CHK APP'D \ c 026 ,. JOB NO. SITE NO. DRAWING NUMBER REV VOICE: 631-689-9450 FAX: 631-689-8459 15 NJ 07652 SCALE: AS NOTED DESIGNED DRAwN xxx ^` f - 24445 903006201 903 006 201 SP-4 B AT &T D AT&T WIRELESS SERVICES , L . L . C . SITE NUMBER : 903 006 201 SITE NAME : FISHERS ISLAND DIRECTIONS DRAWING INDEX REV, TAKE LONG ISLAND EXPRESSWAY(495) EAST TO EXIT 73. CONTINUE ON TO ROUTE 58 EAST, IT WILL TURN PROJECT INFORMATION INTO ROUTE 25 EAST. FOLLOW SIGNS TO TRUCK ROUTE 25 (ALDRICK LANE), TAKE NORTH TO TRUCK ROUTE 25/CR 48 EAST. CONTINUE ALL THE WAY TO THE END. TAKE THE "ORIENT POINT FERRY" TO THE FERRY 903 006 201 T- I TITLE SHEET B TERMINAL IN NEW LONDON, CONNECTICUT. TAKE THE "FISHERS ISLAND FERRY" FROM NEW LONDON, CT. TO SCOPE OF WORK: AN UNMANNED TELECOMMUNICATIONS FACILITY INCLUDING FISHERS ISLAND. DRIVE OUT OF FERRY TERMINAL AND TURN LEFT ONTO GREENWOOD AVE. AT THE END OF TELECOMMUNICATION EQUIPMENT IN BASEMENT AND 903 006 201 A- I PIANS AND NOTES B GREENWOOD, MAKE A LEFT ONTO WHISTLER AVE. CONTINUE ON WHISTLER AVE. UNTIL YOU GET TO RELATED ANTENNAS MOUNTED IN STEEPLE. C EQUESTRIAN BLVD. MAKE A RIGHT ONTO EQUESTRIAN BLVD. UNTIL IT MEETS WITH OCEAN VIEW DRIVE. SITE ADDRESS: ORIENTAL AVENUE 903 006 201 A-2 ELEVATION, ENLARGED EQUIPMENT PLAN, A CONTINUE ON OCEAN VIEW DRIVE TO NEATHULIE AVE. MAKE A RIGHT ON NEATHULIE AVE. CONTINUE ON FISHERS ISLAND, NY 11957 NEATHULIE AVE. TO ETTRICK ST. AND CONTINUE STRAIGHT ACROSS ORIENTAL AVE. TO OUR LADY OF GRACE AND ARCHITECTURAL DETAILS CHURCH ON EAST SIDE OF ORIENTAL AVE. PROPERTY OWNER: OUR LADY OF GRACE CHURCH 903 006 201 A-3 ARCHITECTURAL DETAILS B PHONE: (631 ) 788-7353 903 006 201 A-4 ARCHITECTURAL DETAIL! f VICINITY MAP ADDRESS: ORIENTAL AVENUE, FISHERS ISLAND, NY 11957 A "''Vilp t i,'r- '1.;�i1 ' '1 u1u°Vitt i ' 1'11 , 11v'.' ' 1a i I `t'i{ 111"I 'dIl"I ll'21,11111 ''r''h°I+ +y't-ttw,l1:" �s� ' qn, 1,';,1; CONTACT PERSON: BILL GLENDON, (ATTORNEY) 1d IYI IIS M 1 � Y � �vl I , 1 � Ir iu it I " I , II 1,11 it i z, ' e a a �I 1111 VI � Y1 i -, !ul r 1 , 1 t. t ) fii#'�e,�ll + ' + I In ray llt'd11 � +IlIF 903 006 201 E- I ELECTRICAL RISER DIAGR \MS AND ELECTRICAL NOTES B h ' a l3 iu ,III ' I''li' ' T 4 ,, !1 "'' PHONE: (914) 725-3442 ,$it ,�. 4 xl ysv se a i 'I Ir '1 'I{FF ` ' �ry �' ' pl .".,'' Jlll.,l,Ik,F11 ,.FI'!J'4 11 tn'1?I,1+:11Y'61x {. l,r 1 ,4x"1�1 LgIlI y APPLICANT: 903006201 E-2 ELECTRICAL DETAILS NOTES A AT&T WIRELESS SERVICES, INC, 15 EAST MIDLAND AVENUE lulli h- d1 ili lll.'1n ill, I4s'Ir�IM1 ,I;ISvJ{I r, '11,11 1� , : ' it 1 ,II�IV 't1"1111 ` ' fi''.i� : i 1,,.in r- F 'l 5 E19b J' `F, F';4 903 006 201 E-3 TELCO/ELEC/GROUNDING PLANS, NOTES AND DETAILS B 1 ; 1 ti,' PARaMus, NJ 07652 Pi Ign iillilitl,,'�'ii �I � ' I! {l ,✓t a, v"IF u� : I I: 1 , I x v -++i+ "t ., 1 W4!,�ys�' - A rYsl , , IFrv1j+Lt�is1 , iy_ t a, -:,1} i �^','�ftliil`„li , ,ij: ttl' SvJyl.., Il : II� '_: .^t , [F` , ['Itiy �" '�uil}�, .� LATITUDE: 41' 15' 39.6„ 903006201 E 4 ENLARGED LIGHTING/ELI :CTRIC PLANS, AND A fl,, , ,Y r ;s E lr,,l{ 4 IJ. G y v'1i: 1 , ,., a-:: 3 t„Ir u„ k"AC art 17* `; �'a LONGITUDE: 72' 00' 31 . 1 „ GROUNDING DETAILS ELEVATION: 49'-0" AMSL* 6 P cNnIF, 1, ` f{y'1,�: I � ,iV H'y. r ^HI 11 ty''ti h` lir lkla l' .. q' t Vul .vtl ' r 'a - 903 006 201 E-5 ANTENNA CABLING SCHEMATIC AND DETAILS B ;l lY 'I h'�°Ir!+,ra,1 1t111� 11 „N glia Ic, 1 i..1 1L, 111 1;r , ; ;.,! , -11 I' � ' . �` , fi . m? JURISDICTION: OWN of SOU rHOLD _M1r m ly �iiill l�IlII pry6- t rt, F�,' ', 1iy + ,. a 1{. '�7MP TAX I.D. NUMBER: SECTION: 9 BLK: 7 LOT: 1 1 . 1 ZONING DISTRICT: R-80 � .Cr `"• '•. �I III, 1.�, " ,1 !�r� , :',1 , ' r I� r ) 1 Iu II'"�+� if eTl� � -u' I ,.[ tra tier CURRENT USE: RESIDENTIAL BUILDING '�11''71�11 Pi��,I�7,�p,I1 .I�IR� � t , dU�VP�N r,Id�' 19x11 +'-`, I Ii11q:bV!hMl P11vrP : M .. " I'I rl !'�11� il�V r�y:�llr 'y11 'i 1 PROPOSED USE: RESIDENTIAL BUILDING 14q'°�', �II'I� 1�1�It�+14J�'uG Vr ,a.. II ,N RII II r�4 , r B f y all li ti w I I. r,r i I II 1 le *THE REFERENCED AMSL INFORMATION SHOWN HEREIN HAS BEEN OBTAINED UTILIZING 3- D TOPOQUADS TOPOGRAPHIC MAPPING SOFTWARE BY "DELORME". ACTUAL ELEVATIONS MAY VARY „n1 >rtia11 M11 i rVlll It 'K 1. y r i1� Itli '. 1 tlt, 1 , I�11�s t, A 4 , l ll ,,;� ;`� ' �' Iii; 11o•r+I' � loeiih � r A � I r I 111+ � II � u 1 ,,,,. 1, I,re I; API p� a' � �" a J i � ! ACCORDING TO POINTS OF REFERENCE. 7 11Iwl�^ I r rJ t"1 : I I 1 1 1 1. I i b II 11a, 1111 �r a 4 n: ISK'I I 51,i1x.vf.� p tli 11 11'Ir 1[`' i ' 1'li; lil �gi 11 -Iiy 191 Wli itl'pifiil rll 'Va"'V 11 ',tial"I II , u1 ,I 1 ..I Id1II ' .' 1 , �1j1 �I , f�/. V 1, ilrva , '"�'}I. 1�4„77 I,1 Y� .!,mh1`t 1. I�i 1�, It 1_V 1 ,1 Illli'!1n11111,1 �{i.AJil sr1(i�'.,I I ,dill ' ,I.j:)JII 11� 6,11ya 'si�.�L�lr I'7i l dil 1'4 rill'" I'Y'j41I''�1( 't.;" � SITE QUALIFICATION PARTICIPANTS 11 I d I " � i III Ile{'' 11 �' !: � I "I �' °.II 11 IfIU° 1 ✓t ,4,, 11 IP 'i1t1 ,Ili I S=e, 9111,1 'IIVI 1i,[r I.2 :�' 111x16 igirf 9 e 111'6'. lel7�v-, �.'fA{111 ,171 4,' i n MI P lql,, ih�ll�'I��J. 1 t 14. II I, 1 1 h it l rl'r Qn:l, W f 1,1. 1 .(r 1 p;., NAME COMPANY NUMBER ill-.,�- 7 "LOv r [il„ 1i,l�r l,�fe'i .v1. lu I1'yl rr,i 11 l�:� .d��''I'ill, N { - , :,lrr ;:? li 11 .5. :';I�ir' h b' i�J ,I1 y ,'I�f'ii '','IJi111i Ila r��C'i r ,,a .a+ llj a Inrl,lusl ,u�l;:i'.!.!;h, ul lhr !ul.rx, 111111, li;.l. itrll :orm +r1 � ' � ;hl ` ` ' ��� 1 I I �,' � NEIL A. MACDONALD WILLIAM F. COLLINS, AIA ARCHITECTS, LLP (631 689-8450 el1'yI II��'iJI u11 f II �i P It, 1 111i11 ,h a ylll l 11 a 1' Lr ) l 1 ty ts4' ;Il' SAC MATT BARTLETT HIGHLANDER CONSULTANTS INC. (631 ) 581 -8105 } tUi4 YlJr. yh' a +' iii r 1x11 1: II 11111+ i '1v tq vu'1i a,�l .1r 1, Lsi�11111 { _'9P ul n11'I: i 1 RF SERHAD GUVEN AT&T (201 ) 336-3696 i'. , .., .,t:. ,;,r sr�� CON JOHN THEISSEN BECHTEL TELECOMMUNICATIONS 631 753-6143 ' (jjtB,•EI[ to}g "AA 1 k' 6u t ' nroJ111 III 1 pr, t 'v 4 rN� 1 1 a 1 .r;pl A l 11 i_tl� ,�, a iN}p1 l l ryif, Irl ( 11. 4' ivi'41(¢ i ( ) ljlrA9hr`,3i , 1. fE It ,, li - _ ':',Li 1 �kul, id I I:-nlll'1��I,� II ;:� 1- 1. � IrI' A LANDLORD N/A N/A N/A Q FC PROJECT NO " FISHERS ISLAND DER Ai ti, 02-4926 AT&T WIRELESS SERVICES =--.- o :�y WILLIAM F. COLLINS, AIA 903 006 201 AT&T - -m2l - - A R C H I T E C T S, L L P 0 s/is/o} slued FOR zoN1Nc Ac,au AF n ' * TITLE SHEET ORIENTAL AVENUE 10/30/02 ISSUED FOR REVIEW PL AF II 1al lEc@Ioc oar 50 sa X: 631,N9.9459 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. NO, DACE REVISIONS By CHK APP'O 06 JOB NO. SITE NO. DRAWING NUMaER Rev VOICE: 631-639-8450 PAX: 631fi89�8459 75 EAST MIDLAND AVENUE �J��� f„ PARAMUS, NJ 07652 SCALE AS NOTED DesicNED DRAWN. xsx 24445 903006201 903 006 201 T- 1 B 5 4 3 2 DFN=STV[160,021 .DWG 22 H 34 T SIZE 6 PSC= . NEW SECTOR "A" GENERAL NOTES: ANTENNA MOUNTED 7z� BEHIND NEW RF = LINE OF EXISTING EXISTING STRUCTURE, TRUE NORTH, AND MISCELLANEOUS 11 THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND TRANSPARENT � a= GABLE ROOF BELOW INFORMATION WERE TAKEN FROM VARIES SOURCES OF MATERIALS ACCORDING TO THE MANUFACTURER'S � � 0 0INFORMATION, I.E.: FIELD MEASUREMENTS, PHOTOGRAPHS SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOUVER PANEL oAND INFORMATION FROM AT&T. THIS PLAN DOES NOT LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. NEW COAXIAL � • � Lo REPRESENT AN ACTUAL SURVEY PERFORMED BY WILLIAM F. ANTENNA CABLES �n � � COLLINS, AIA ARCHITECTS, LLP OR ANY OTHER THIRD 12. CODE AND STANDARDS: ROUTED FROM NEW ~ NEW LAND LINK PARTY. ALL CONSTRUCTION SHALL MEET OR EXCEED ALL AT&T EQUIPMENT —= _ EXISTING ELECTRICAL METER NEW 200 AMP "APPLETON" 1 MOUNTED TO EXTERIOR GENERATOR RECEPTACLE E_1 E 1 FACADE OF BUILDING AT GRADE 8'-9 1 /4" NEW AT&T EL AMP ATTACH WITH 2 POWER PANEL E-t ( ) # 14X3" LONG GALVANIZED NEW 200 AMP AT&T WOOD SCREWS OR 3/8" GALVANIZED LAG DISCONNECT MOUNTED EXISTING ELECTRICAL PANEL BOLTS FOR USE IN WOOD FRAMING BELOW NEW SUB-METER �J - ' AND PLYWOOD BACKBOARD EXISTING LOUVERS TO BE cn REPLACED WITH NEW RF NEW AT&T SUB-METER EXISTING SMOKE DETECTOR ( ) / I- — UNISTRUT P1000 OR EQUAL 1 5 8" x 1 5/8" TRANSPARENT LOUVER RE LA REMOVED AND Ln o REPLACED WITH NEW 4 v1 WITH HOT-DIPPED GALVANIZED FINISH NEW COAXIAL ANTENNA =_' _-"_''='= oz — UNISTRUT PIPE CONDUIT CLAMPS P2558 OR PANELS, TYP. OF (3) s55 CABLES ROUTED ON SMOKE DETECTOR O EQUAL PIPE/ LOCATIONS AT UPPER - I FUTURE STEEPLE O EXISTING DOOR AND DOOR N PIPE OR CONDUIT UNISTRtTO THROUGH Mrs 1 �_ FLOORSTEEPLEIW DMA , FRAME TO BE REMOVED AND SECTOR "B" ANTENNAS ABOVE FFur�RE _ REPLACED WITH NEW 3'-0" MOUNTED BEHIND NEW RF N KIA FIRE-RATED DOOR AND a EXISTING CEILING SYSTEM LT ASITEI r - FRAME, TYP. EXSTING WALL OR CEILING A_ TRANSPARENT LOUVER TO BE REMOVED AND L ABINET� T PANELS, TYP. OF REPLACED WITH NEW DASHED LINES INDICATE SECTION ALL SECTORS 1 1 /2 HR. FIRE RATED OF EXISTING DOOR JAMB, WALL NOTE: 36'-4"t A.G.L. CEILING AND DOOR TO BE REMOVED TYPICAL FOR WALL OR CEILING MOUNTED APPLICATIONS. '700RAD. (L OF ANTENNA NEW THROUGH WALL 6 �_ r EXISTING WOOD PLANK FLOORING _ EXHAUST FAN TO 2'-Q TO BE REMOVED. SEE NOTE THIS 30'-11 "f A.G.L. REPLACE EXISTING DETAIL FLOOR OF UPPER _ WINDOW AND FRAME �NEW T STEEPLE L - - BA KBOARD TELCO ODSCAEIA�L @CONDUIT SUPPORT ----------- NEW COAXIAL ANTENNA NEW SECTOR "A" LINE OF 555 NEW COAXIAL ANTENNA //'\/5/5\5 ANTENNA EXISTING GABLE —s — CABLES ROUTED UP F _s _ CABLES ROUTED H ON _ ROOF BELOW UNISTRUT THROUGH EXISTING HORN, TYP. THROUGH CEILING ON o � EXISTING FIRST FLOOR EXISTING EXISTING LOUVERS TO BE UNISTRUT TO EXISTING _:._- -- STORAGE ROOM CEILING STORAGE ROOM REPLACED WITH RF FIRST FLOOR STORAGE 'FUTURE NEW AT&T AND LOWER STEEPLE EXISTING 2 7 sss NEW COAXIAL TRANSPARENT LOUVER ROOM ABOVE IwcoMAl EQUIPMENT AREA ABOVE O SANCTUARY - - - ANTENNA CABLES _— ; ITIRE� ROOM AREA ROUTED UP FROM ' � �i i PANELS, TYP. T S • "o"A LOWER STEEPLE SEE DETAIL 2, THIS CABIN � —5 SHEET BELOW ON UNISTRUT i , ./ TO NEW AT&T AN NEW LD LINK a 1 _ EXISTING STATUES, ANTENNAS MOUNTED 1 d,_ PARABOLIC ANTENNA -s ID EXISTING � EXISTING TO INSIDE FACE OF TYP. OF (3) UPPER STEEPLE CONTRACTOR TO RELOCATE EXITING THRIFT WORSHIPII HORN TO ACCOMMODATE POSITIONING STORE �_ — AREA �_ I OF NEW PARABOLIC ANTENNA EXISTING ACCESS NEW SECTOR "C" LL —_ _ ANTENNAS CONTRACTOR TO PROVIDE CONTINUOS 2x6 WD. HATCH TO STEEPLE xf BRIDGING BETWEEN FLOOR JOISTS WITHIN HATCHED ABOVE L—�U DASHED LINE INDICATES /_., AREA, AND SOLID BLOCKING AT BEARING POINTS. EXISTING WOOD PATCH ROOFING MEMBRANE AS REQ'D II FRAMING MOUNTED II I O FROM CEILING ABOVE LINE INDICATES L.. E NEW SECTOR "B" HIGH POINT IN ANTENNAS SLOPED FLOOR z EXISTING ACCESS HATCH TO LOWER EXISTING STAIRS EXISTING STAIRS STEEPLE BELOW FROM BASEMENT FROM BASEMENT LINE OF jN EXISTING GABLE ROOF BELOW BASEMENT PLAN FIRST FLOOR PLAN UPPER STEEPLE PLAN ANTENNA CABLE ROUTINGm PLANS NOTE: a, 2' 4' a NORTH 1 SCALE: 1 4" = 1 '-0' IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. 1/4"=1 '-0" NEW ; "x4"X3/8" NOTES: GALVAIJIZED STEEL RIGGERS TO DELIVER ANTENNA THROUGH LOUVER ANGLE , TYP. SECURED ROUGH OPENING AT TIME OF LOUVER REPLACEMENT. 9 1 /4" 5 -0 WITH 5/8" LAG BOLTS, 611 10'-6" BOLT \T EACH EXISITNG V- 11 1 /4" 6 2'-0" 2'-7 1/2" 2'-0" 1 -11 1 /4" NEW °S6" TRIPOD, 1 '-5' 6 2'-0" STUD _OCATION WHERE "MICROFLECT" A OCCUFS PART#91013 NEW : "ZED S 4" ° GALVAIJIZED STEEL ANGLE SECURED TO B 7"x4"x3/8" ANGLE WITH *lV- V-6" 1 /4" CONTINUOUS WELD, NEW LAND LINK s V.I.F YPPARABOLIC ANTENNA, "ANDREW" 1 /2% GALVANIZED FPART#P35-52 \„ STEEL U-BOLT, TYP. NEW PANEL ANTENNA,----_. N EJ 1 ' 9' --� { SEE DET. 1 /E-5 EXISTING WOOD FRAMING MOUNTED FROM CEILING. V — % EXISTIIIG HORN, TYP. OF (4) LnIt HORN NOT SHOWN FOR \ REASONS OF CLARITY Ln EXISTIf IG WOOD FRAMING, TYP., /.I.F. NEW RF TRANSPARENT B LOUVER PANELS, TYP. NEW 2 -3/8" O.D. OF (3), SEE NOTE GALVAIJIZED STEEL PIPE, THIS DETAIL TYP.— 5/8" DIA. COAXIAL NEW RE TRANSPARENT ANTENNA CABLE TOUTED LOUVE'2 PANELS, TYP. ON UNISTRUT ALONG OF (3), SEE NOTE THIS sss INTERIOR WALL OF DETAIL o UPPER STEEPLE, TYP. BOLT AT EACH EXISITNG 7/8"4 COAXIAL ANTENNA STUD LOCATION WHERE CABLES ROUTED ON ° ° OCCURS ° UNISTRUT ALONG sss INTERIOR WALL OF ° ° ° ° ° ° ° UPPERSTEEPLE, TYP, � ______—______'-=_________ '___==-=-L=====___ BOLT AT EACH EXISITNG A 6'- 10" CONTRACTOR TO PROVIDE 5'-3" A 4'- 10" STUD LOCATION WHERE R.O., TYP. NECESSARY SHIMS oCCURs nTYPICAL SECTION To MAKE NEW "S6" TYPICAL ELEVATION TYPICAL SECTION ., n NOTES: UTYPICAL ELEVATION CONTRACTOR RESPONSIBLE FOR TRIPOD PLUMB, V.LF. U FOR STANDARD PANEL ANTENNA MOUNTING DETs41LS B FABRICATION AND INSTALLATION PARABOLIC ANTENNA MOUNTING DETAIL ANTENNA MOUNTING DETAIL, 2 SCALE 3/4" = V-0" OF RF TRANSPARENT PANELS. 3 SCALE: 3 4' = 1 —o ' SEE DETAIL 2 THIS SHEET. ZI WFC PROJECT NO FISHERS ISLAND AT&T 02-4926 AT WIRELESS SERVICES WILLIAM F. COLLINS, AIA 903006201 s/is/m ISSUED Ac,dM Ar ARCHITECTURAL DETAILS A R C H I T E C T S, L L P Elm ORIENTAL AVENUE Q 10/30/02 issusD FOR REVIEW 104 TECHNOLOGY DRIVE SETAUKET,NY1193J FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. "D DATE REASiORS ev cw< Amro JOB NO. SITE NO. DRAWING NUMBER REv VOICE: 631-689.8450 FAX: 631689-8459 75 EAST NAVENUE J PARAMOSS,, NJ s7ssz score As NOTED DEsicNeo DRAWN xxx "'- 24445 903006201 903 006 201 A-3 I B EXISTING STUD WALL SEE SCHEDULE SEE SCHEDULE EXISTING MASONRY WALT_ N N NEW 2 HR. SHAFT WALL DOOR AND HARDWARE SCHEDULE DOOR AND HARDWARE SCHEDULE HOLLOW METAL DOOR "i NEW 1 /2" GYPSUM BOARD ON RESILLIENT DOOR #1 : 3'-0" x 6'-8" x 1 3/4" 16 GAUGE 24" DOOR #2: 3'-0" x 6'-8" x 1 3/4" 16 GAUGE ,I FRAME CHANNEL INSULATED METAL, 1 1 /2 HR. "B" INSULATED METAL WITH 24"x24" STORM HOLLOW METAL DOOR AS I LABEL. PROVIDE UL RATED WIDE-ANGLE PROOF LOUVER W/ BIRD SCREEN. PAINT SCHEDULED (FISHEYE) PEEPHOLE. PAINT SUMMIT SUMMIT GRAY. THRESHOLD BELOW GRAY. FRAME: 3'-0" x 6'-8" 16 GAUGE HOLLOW FRAME: 3'-0° x 6'-8° 16 GAUGE HOLLOWN METAL 1 1 /2 HR. FPSC. CAULK WATER nJAMB (HEAD SIMILAR) nJAMB (HEAD SIMILAR) w METAL 1 1 /2 HR. "B" LABEL. CAULK LL] TIGHT AROUND EXTERIOR PERIMETER. WATER TIGHT AROUND EXTERIOR U v J J PAINT SUMMIT GRAY. D PERIMETER. PAINT SUMMIT GRAY. HINGES: 1 1 /2 PAIR 4 1 /2"x4 1 /2"xSTD. EXISTING STUD WALL o HINGES: 1 1 /2 PAIR 4 1 /2"x4 1 /2"'xSTD. o WEIGHT, BALL BEARING HINGES WITH BEYOND = WEIGHT, BALL BEARING HINGES WITH C CONCEALED SETSCREW TO LOCK IN HOLLOW METAL FRAME Un 2 2 CONCEALED SETSCREW TO LOCK IN Ln 2 2 BEYOND w HINGE PIN. STANLEY N0. FBB191 . HINGE PIN. STANLEY NO. FBB191 . 3 w w DOOR #2 SCHLAGE L-SERIES LOCK AND DEAD HOLLOW METAL DOOR AS NEW VCT FLOORING n DOOR1 SCHLAGE L-SERIES LOCK AND DEAD # LOCKSET: BOLT ASSEMBLY, MODEL# L94P, 7 c_ SCHEDULED 1 LOCKSET: BOLT ASSEMBLY, MODEL# L94P. 3 CLOSER: LCN 4010 SWEEP WITH RAIN DRIP CLOSER: LCN 4010 STOP: CANVAS OR RUBBER COVERED CHAIN THRESHOLD SET IN STOP: STEEL BRUSHED CHROME FINISH STOP, RUBBER FLOOR STOP . WEATHER- SEALANT WEATHER- STRIP: VINYL BULB TYPE AT HEAD AND JAMBS. STRIP: CONTINUOUS SMOKE PROOF GASKETING. SILL UTHRESHOLD 4 THRESHOLD 2 4 PROT: BRUSH TYPE. THRES- HOLD: ALUMINUM THRESHOLD IMBEDED IN DOOR #1 DOOR #2DOOR #1 DOOR #2 SEALANT. SCALE: 1 1/2"=l '-0" SCALE: 1 1/2"=V-0" SCALE: 3/4"=V-0" SCALE, 3/4"=V-0" DOOR DETAILS 1 SCALE: AS NOTED Q FC PROJECT NO FISHERS ISLAND - 02-4926 AT&T WIRELESS SERVICES Q '., /S)ER ,ykcy/F WILLIAM F. COLLINS, AIA 903 006 201 AT&T ARC H I T E C T S, LLARCHITECTURAL DETAILS ORIENTAL AVENUE -- P � = � # QA 10/]x/42 ISSUED FOR REVIEW PE AF II _ . AT&T WIRELESS SERVICES, INC. • V 10.1 TECHNOLOGY DRIVE EEX: 631,689-8459 FISHERS ISLAND, NY 11957 No. 6aiE REVISIONS 6Y cRN aPP'6 626944 _/JOB NO SITE 680. DRAWING NUMBER REV 75 EAST MIDLAND AVENUE p O VOICE: 63189-8456 FAX: 631-b89-8459 PARAMUS, NJ 07652 F scnEE: as NOTED DESIGNED DRAWN xxx OF Nb`N 24445 903006201 903 006 201 A-4 A LEGEND : NOTES: RU — RELAY TO MONITOR UTILITY POWER 1 . SUBCONTRACTOR SHALL PROVIDE 200AMP, THREE OA NEW 2.5" C WITH 4-4/0 & 1 # 6 THHN CU NEW LAND LINK PARABOLIC PHASE, 120/208 VAC, 60HZ SERVICE FOR AWS SITE ANTENNA 2, SUBCONTRACTOR SHALL COORDINATE WITH UTILITY NOTE: COMPANY BEFORE THE START OF CONSTRUCTION. USE THREADED COUPLINGS ONLY POWER CONDUIT SHALL BE PROVIDED AND INSTALLED GROUND PIPE AT EACH END PER UTILITY NEW 30"x30"x10" TELCO BOX 3. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT WITH GFI RECEPTACLE FED REFER TO DRAWINGS PROVIDED BY PANEL NOTE NOTE NOTE NOTEMANUFACTURER. E1 E2 E3 E4 FROM NEAREST SERVICE. 4. ALL SERVICE EQUIPMENT AND INSTALLATIONS SHALL 2" CONDUIT WITH 4 PR. COMPLY WITH THE N.E.C. AND UTILITY COMPANY AND URG NEW CAT 5 CABLES & LOCAL CODE REQUIREMENTS. KwH NEW A REST R ANE TELCO BOX (SEE NOTE 9) PULLSTRING 5. SUBCONTRACTOR SHALL INSTALL SUFFICIENT LENGTHS 200A P1 WITH A 66—B3-50 BLOCK FRAME REF. DETAIL# 1022 SHEET E-2 OF LFMC INCLUDING ALL CONDUIT FITTINGS (NUTS, SWITCH A REDUCING BUSHINGS, ELBOWS, COUPLING, ETC) FOR ALARM ASSIGNMENT FOR CONTINUATION NECESSARY FOR CONNECTION FROM THE NEMA BOX NOTE NOTE RELAY ALARM CABLES SEE DETAIL 1 , TO THE EXTERIOR NOKIA POWER CABINET. _ E6 E5 #2 AWG GROUND FROM PANEL TO SHEET E-1 NOTE CEN NOTE CONDUCTOR ULTRASITE CABINET, 6. SUBCONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE E8 REG E7 4 —PAIR #22-24 AWG IN EQUIPMENT WITH FAULT CURRENT RATINGS GREATER BASEMENT SEE NOTE 8 3/4" CONDUIT SEE NOTE 11 6200A FUSED THAN THE AVAILABLE FAULT CURRENT FROM THE DISCONNECT POWER UTILITY. 7. POWER, CONTROL AND EQUIPMENT GROUND WIRING IN NOTE 2 TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR 3/4" LFMC 1 /2" LFMC (#14 AWG AND LARGER), 600V, OIL RESISTANT THHN NEW RISER DIAGRAM SEE NOTE 5 2.5" C WITH 4-4/0 OR THWN-2, CLASS B STRANDED COPPER CABLE & 1 # 6 THHN CU RATED FOR 90-C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, R 200A 8• CUT, COIL AND TAPE A 3 FOOT PIGTAIL FROM END OF E1 . COORDINATE ALL NEW WORK WITH LIPA FOR THE E5. PROVIDE AND INSTALL SURGE ARRESTOR SEE---/ LFMC FOR TERMINATING BY BTS EQUIPMENT ADDITION OF THE NEW 200 AMP SERVICE, INNOVATIVE TECHNOLOGY INC„ IT PROTECTOR NOTE 10 MANUFACTURER. E2. PROVIDE AND INSTALL NEW SUB—METER #PTE/80/PTXO80. NOKIA NOKIA 9. SUBCONTRACTOR SHALL FURNISH AND INSTALL A E6. PROVIDE AND INSTALL NUMBER 2 COPPER ULTRASITE POWER 40A 30"x30"x10" NEMA 3R ENCLOSURE WITH INTERNAL 200AMP, 3—PHASE E3. PROVIDE AND INSTALL NEW 200 AMP, 3 POLE GROUND AND 3/4" x10' GROUND RODS FOR CABINET CABINET 5/8" THICK PLYWOOD BACKBOARD. SUBCONTRACTOR " CONDUIT WITH(2) 4 PAIR, POWER PANEL "P1 ", SHALL COORDINATE WITH LOCAL TELCO UTILITY PRIOR FUSED DISCONNECT SWITCH WITH SOLID NEUTRAL NEW SERVICE. MAXIMUM RESISTANCE TO (BACK) (BACK) 40 SEE NOTE E-6 RATED FOR SERVICE ENTRANCE EQUIPMENT. FUSE GROUND SHALL BE 5 OHMS. PROVIDE AND CAT 5, UTP CABLE FOR TO PROCURING AND INSTALLATION S OF ENCLOSURE AND TELCO SERVICE (REF. DET.# DETAIL 1 THIS COMPONENTS. SUBCONTRACTOR SHALL FURNISH AND WITH THREE BUSSMAN FRN 200 FUSES. INSTALL ADDITIONAL GROUND RODS NOT LESS SHEET INSTALL SURGE PROTECTION DEVICES (BY ATLANTIC THAN 6' APART TO MEET MINIMUM GROUNDING 1016 SHEET E-2); (1 ) 26 40 E4. PROVIDE AND INSTALL NEW SQUARE "D" NEMA 3R, CONDUCTOR EXTERNAL SCIENTIFIC; ZONE BARRIER SERIES; PART N0, 90700 SURFACE, 20" WIDE CABINET MODEL# REQUIREMENTS, ALARM CABLE (REF. DET.# WITH MOUNTING DIN RAIL PART NO. 21607). BOND NQOD43OL225CU PANEL P1 . PANEL SHALL BE E7. PROVIDE AND INSTALL BRANCH CIRCUIT WIRING TO 1020) SURGE PROTECTION DEVICE DIN RAIL TO THE RATED 200A, 120/208 VOLT, 3 PHASE WITH A GFCI RECEPTACLE, FIRE DAMPER/ FAN, NOKIA ENCLOSURE WITH #6 AWG INSULATED WIRE 200A MAIN BREAKER, ALL COPPER BUS, BOLT ON CABINETS, ETC. PER OWNERS REQUIREMENTS. (REFERENCE STANDARD DETAIL 1015). BOND ENCLOSURE TO THE SITE GROUND RING OR BAR WITH BREAKERS AND DOOR IN DOOR HINGED COORDINATE WITH PROJECT MANAGER AS CONSTRUCTION. NECESSARY. #2 AWG SUPPLEMENTAL, #2 AWG COPPER WIRE. E8. PROVIDE AND INSTALL 200A, 3 PHASE, 4 WIRE EQUIPMENT GROUND (3) 40A 2P 2W+G 10. SUBCONTRACTOR SHALL PROVIDE SN6%4" (MIN.) NEMA PIN AND SLEEVE GENERATOR RECEPTACLE. CONDUCTOR _ _ 3R STEEL ENCLOSURE AND MOUNT TO CONDUIT RACK RECEPTACLE SHALL BE "APPLETON" SEE NOTE CKT NOTE AT REAR OF CABINET. 5 ADJA20044-200 SERIES WITH MOUNTING BOX. LOCATE RECEPTACLE ON EXTERIOR OF SHELTER AT A LOCATION APPROVED BY PROJECT MANAGER. ELECTRICAL RISER DIAGRAM2S SINGLE LINE DIAGRAM 1 SCALE: N.T S. ELECTRICAL NOTES: 1 . CONDUIT ROUTINGS ARE SCHEMATIC, CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 2. THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT 3. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. 4. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. • 5. ALL DISCONNECT SWITCHES SHALL BE SIZED AND HAVE NEMA ENCLOSURE AS STATED ON THE DRAWINGS. SWITCHES SHALL BE QUICK MAKE, QUICK BREAK, GENERAL DUTY, HORSEPOWER RATED. FUSES SHALL BE BUSSMAN TYPE RK- 1 CURRENT LIMITING, TIME DELAY—DUAL ELEMENT. 6, RELOCATE AND RECONNECT, AS REQUIRED BY CONSTRUCTION, OUTLETS, LIGHTS, OR OTHER ELECTRICAL EQUIPMENT ENCOUNTERED DURING CONSTRUCTION. EXISTING ELECTRICAL EQUIPMENT, WHICH IS TO REMAIN BUT IS ON THE SAME CIRCUIT AS EQUIPMENT BEING REMOVED, SHALL BE RECONNECTED AND LEFT IN OPERATING CONDITION. FC PROJECT AT&T0 NEPED A11?6 02-4926NO AT&T WIRELESS SERVICES FISHERS ISLAND — T �y o� 4�0 � WILLIAM F. COLLINS, AIA 903006201 �� R Q 5/15/03 ISSUED FOR ZONING AG.JM Ar r w ELECTRICAL RISER DIAGRAMS � * AND ELECTRICAL NOTES A R C H I T E C T S, LLP ammill"­ Q 10/30/02 ISSUED FOR REVIEW K A!, 7 .r. ORIENTAL AVENUE AT&T WIRELESS SERVICES, INC. 026 " JOB NO. SITE NO. DRAWING NUMBER REv 10-ITECENOLAOYO6IVE SErAUXET,NY1173a FISHERS ISLAND, NY 11957 No. Dare REvislorvs Rr GRN AaP'D rF , VOICE: 631.689-8450 FAX: 631689-8459 15 EAST MIDLAND AVENUE PgRAMue, NJ 07652 scAUE. as NOTED— DESIGNED DRAWN: %%% �� N` 24445 903006201 903 006 201 E- 1 I B INNOVATIVE TECHNOLOGY, INC , TO RADIO CABINET NOTES: (NOKIA/ERICSSON) TI SURGE SUPPRESSOR 1 . MOUNT 66-B3-50 BLOCK IN TELCO BOX OR ON ATLANTIC SCIENTIFIC NO. TELCO BACKBOARD. TRANSIENT VOLTAGE SURGE `.SUPPRESSOR 90700 (SEE NOTE 2) WHT/BLU 0 O 1 2. WIRE TO PROVIDE CONTINUITY WHEN CIRCUIT IS NORMAL, COMMERCIAL TO AC SERVICE PORT MARKED ( BLU WHT 2 ENTRANCE CABINET "PROTECTED" DIN RAIL ATLANTIC PWR FAIL MODEL DESCRIPTION PEAK AMPS RJ48 (TYP) SCIENTIFIC 21607 3. INSTALL BRIDGING CLIPS (SIEMENS-SA- 1 -25 OR WHT ORG EQUIVALENT) AS REQUIRED. ( ORG/WHT PTX080-3Y101 TVSS 80,000 WHT GRN 5 SURGE SUPPRESSOR THREE PHASE PLASTIC 4. TURN BACK AND STORE UNUSED CONDUCTORS. TVSS FAIL TVSS FAIL GRN WHT 6 NOTCH WHT/BRN SURGE SUPPRESSOR BRN/WHT 1 SCALE: N.T.S. WHT/SLT CSLT/WHT PANEL °P1 „ RED/BLU LABEL ( BLU/RED TVSS 3P30 GFI RECEPTACLE 1P15 2 3 ♦ SMOKE DETECIOR1P15 4 ALARM CABLE / RED ORG NOTE 4 TO ULTRASITE, (` ORG/RED 5 ♦ EXHAUST FAN 1P15 6 (REFERENCE 7 NOKIA #1 2P40 CORD REEL 1P15 8 DETAIL 1020 RED GRN PORT MARKED THIS SHEET) ( GRN/RED 9 ♦ TELCO RECEPTACLE IP15 10 "UNPROTECTED" RED BRN 11 NOKIA #2 2P40 INTERIOR LIGHTS/II iP5 12 RJ48 (TYP) #6 AWG C BRN/RED 13 ♦ INTERIOR RECEPTACLES 1P15 14 BONDED TO)ENCLOSURE RED/SLT NOTES: GROUNDED SLT/RED 15 NOKIA #3 2P40 MOTION SENSOR 1P15 16 TO TELCO 1 . MOUNT DIN RAIL TO BLK BLU 17 ♦ SPACE 18 NIU BLU BLK TELCO BOARD / 19 SPACE SPACE 20 2. DIN RAIL HOLDS 1 -4 / BLK/ORG 21 SPACE SPACE 22 UNITS ORG/BLK 3. TVSS MAY BE ORIENTED TO 23 SPACE SPACE 24 SUIT SITE REQUIREMENTS. BLK/GRN LK 25 SPACE SPACE 26 GRN/B 27 SPACE SPACE 28 T1 SURGE SUPPRESSOR 29 SPACE SPACE 30 01 SCALE: N.Ts. N OTE: 1 , CONTRACTOR SHALL PROVIDE BRANCH CIRCUITS TO ALL EQUIPMENT SHOWN VENDOR CDS DATACOM INC. ATLANTA CABLE SALES INC.(ACS) WHT/BLU ON PANEL SCHEDULE AND FLOOR PLANS FOR A COMPLETE INSTALLATION, 2114-340-9199 800-241 -9881 1 BLU/WHT COMMERCIAL PANEL SPECIFICATIONS OUTDOOR DOUBLED ENDED P# C00411484—XXX P# 010717-1 —XXX 20 POWER FAIL WHT/ORG 120/208V, 3 PHASE, 4 WIRE INDOOR DOUBLED ENDED P# C00411467—XXX P# 010716-1 —XXX 2 1 AL13 MAINS: 200A PANEL CIRCUIT BREAKER OUTDOOR SINGLE ENDED P# C00411483—XXX P# 010717—XXX 21 ORG/WHT J 200A BUS WHT/GRN ENCLOSURE: NEMA 3R, SURFACE, 20" WIDE CABINET UIODEL# NQOD43OL225CU INDOOR SINGLE ENDED P# 000411450—XXX P# 010716—XXX 3 GRN/WHT TVSS FAIL POLES: 30 XXX = LENGTH IN FEET 22 J WHT/BRN PANEL SHALL BE 42K AIC OR BETTER AND HAVE BOIT ON BREAKERS AND 1234 ]8 4 BRN/WHT 1 AL15 WELDED GROUND BAR KIT, COVER SHALL BE LOCKAB -E WITH HINGED DOOR 1 BLU HT T 23 J IN DOOR. 2 WHT BLU R TX THROUGH 5 WHT/GRY AL16 N PANEL SCHEDULE 3— NG CABLE 24 GRY/WHT 1 0 � 4 0 HT T CONFIGURATION" 6 RED/BLU AL17 m o J 2 SCALE: N.T.S. 5 W ORG RX 25 BLU/RED ) � ED 6 NC RED/ORG \ AL18 g D ELECTRICAL SYMBOLS ABBREVIATIONS NC 7 J _ 7 ORG/RED 1` ® Of GROUND ROD WITH ACCESS AWG AMERICAN WIRE GAUGE 8 NC o 0 26 Do w RED/GRN AL19 I w ^ e BCW BARE COPPER WIRE RJ48C CONNECTOR PIN ASSIGNMENT 0 0 8 GRN/RED ) n [ CHEMICAL GROUND ROD 8 PIN DWG DR0ING CONNECTOR 18" GROUND PIGTAIL 27 RED/BRN AL20 U7 o m un GROUND ROD (GND @ BTS CABINET ONLY BY BTS VENDOR) 0 0 9 EMT ELECFRICAL METALLIC TUBING o 0 28 BRN/RED o a = DISCONNECT SWITCH NOTES: w GEN GENERATOR o RED/GRY ¢ °O O O O O METER IGR INTERIOR GROUND RING (HALO) 1 . CABLE IS A NOKIA SPECIFIC DESIGN. WIRING IS UNIQUE AND SHALL BE USED FOR o 0 0 10 1 AL21 NOKIA ULTRASITE INSTALLATIONS ONLY. 0 ° 29 GRY/RED ) NOTE 3 IMC INTEF MEDIATE METALLIC CONDUIT 11 BLK/BLU \ AL22 P CIRCUIT BREAKER MGB MASTER GROUND BAR 2. SELECTED CABLE MUST BE FROM A VENDOR LISTED IN THE ABOVE TABLE 0 0 30 BLU/BLK J CADWELD TYPE CONNECTION PCS PERSONAL COMMUNICATION (NO SUBSTITUTIONS ARE PERMITTED) 0 0 12 BLK/ORG AL23 SYSTI.M 3. DOUBLE ENDED CABLES ARE STANDARD. SINGLE ENDED OPTIONAL TO MEET UNIQUE mo5o 31 ORG/BLK COMPRESSION TYPE CONNECTION SITE REQUIREMENTS. PTS POWER TRANSFER SWITCH BLK/GRN GROUNDING WIRE PVC RIGID (SCH. 40) POLYVINYL 19 REFERENCE POINT 66- B3-50 HT—THROUGH WITH IDENTICAL CONNECTOR PIN—OUT ON BOTH O DRAIN CHLORIDE CONDUIT 4. CABLE IS A STRAIG ) NC REPRESENTS DETAIL NUMBER RGS RIGID GALVANIZED STEEL ENDS. +— REFERENCE SHEET NUMBERMALE 37 PIN D CONNECTOR RWY RACEWAY 5. CABLE END WITH 18" GROUND PIGTAIL SHALL BE INSTALLED AT NOKIA BTS. TYP TYPICALREAR VIEW (CONNECT TO 6. ORDER LENGTH (XXX) AND TYPE (OUTDOOR, INDOOR) AS APPROPRIATE FOR SITE ULTRASITE EXT. ALARM INPUT) ALARM CABLE (ASU84881 ELECTRICAL SYMBOLS REQUIREMENTS (CDS DATACOM P/N 002510313—OOXX) AND ABBREVATIONS 01 T1 CABLE AND CONNECTOR PIN-OUT 02 ALARM CABLE 02 66 BLOCK ALARM ASSIGNMENTS O SCALE: N.T.S. SCALE. N.T.S. SCALE: N.T.S. -•_ YVFC PROJECT NO "`- %- 02-4926 AT&T WIRELESS SERVICES FISHERS ISLAND _ A &TODER ���``�� WILLIAM F. COLLINS„AIA 903006201 n�� ELECTRICAL DETAILS AND NOTES -- A R C H I T E C T S, L L P 0 m/.w/oz ISSUED FOR REVIEW PU AF TT ` �, — ORIENTAL AVENUE AT&T WIRELESS SERVICES, INC. ozs ay' y/ 1411'ECEEQOIAOY DRIVE 9BTAUKHT,NY Il733 FISHERS ISLAND, NY 1195] No DATE RE�nsiDNs BY CHK APP'D �TF { JOB NO SITC N0. DRAWING NUMBER REV 75 EABT MIDLAND AVENUE �F PIF" - � VOICE: 631.689-8450 FAX: 631-6894459 PARAMUS, NJ 07652 SCAUE: AS NOTED DESIGNED DRAWN XXX � 24445 903006201 903 006 201 E-2 A NOTE: #2 AWG STRANDED, INSULATED COPPER WIRE NEW ELECTRICAL CONDUIT ROUTED NEW AT&T 200 AMP POWER PANELE,1 MAY BE USED IN LIEU OF SOLID BCW FOR FROM NEW AT&T SUB-METER TO NEW BONDING DEVICES FROM INSIDE SHELTER TO THE EXTERIOR GROUND ROD . tEXISTING AT&T EQUIPMENT NEW AT&T 200 AMP "APPLETON" GENERATOR RECEPTACLE ELECTRICAL UTILITY METER EXISTING ELECTRICAL PANEL AND PLYWOOD NEW AT&T SUB-METER BACKBOARD GROUNDING NOTES: CAUTION!: AT ALL SITES THE CONTRACTOR MUST VERIFY THAT THE SYSTEM IS EFFECTIVELY GROUNDED AND MEETS THE NEC ARTICLE 250 NEW AT&T 200 AMP REQUIREMENTS AND ACCEPTABLE TO THE LOCAL INSPECTOR/AUTHORITY. NEC ARTICLE 250-84 SPECIFIES GROUNDING RESISTANCE OF 25 OHMS OR DISCONNECT MOUNTED EXISTING SMOKE DETECTOR LESS FOR THE GROUNDING SYSTEM. THE PROJECT REQUIREMENT IS FIVE (5) OHMS. —\ BELOW NEW SUB-METER NEW TELCO COAXIAL CABLE ROUTED FROM NEW LAND LINK PARABOLIC ANTENNA IN FUTURE li �\ NATE: UEI STEEPLE ABOVE TO NEW TELCO BOARD NEW AT&T EQUIPMENT DNA 1 . METALLIC OBJECTS LOCATED WITHIN 6'-0" OF GROUNDING HALO SHALL BE BONDED TO GROUNDING HALO WC ROOM INOKIAFNOMA I - 2. PROVIDE STRAIN RELIEF AND PROTECTION FROM SHARP MATERIAL FOR INDIVIDUAL CABLES. PROVIDE #6 GROUND CONDUCTORS WITH TWO-HOLE PcnewEr CONNECTORS TO CABLE RACK SECTIONS TOGETHER NEW EXHAUST FAN 5/8FIRE RESISTANT NOTES: BACKBOARD " PLYWOOD 1 . FOR NUMBER OF GROUNDING RODS REQUIRED, REFER TO AT&T WIRELESS SERVICES, INC. TECHNICAL SPECIFICATIONS FOR FACILITY GROUNDING. I 2. GROUND WIRES SHALL BE ROUTED INTO THE EQUIPMENT ROOM FOR CONNECTION TO THE FOLLOWING: - BOND GROUND WIRE TO INTERIOR GROUND RING HALO AT A MINIMUM OF FOUR PLACES AND LOCATE CONNECTIONS ON OPPOSITE SIDES OF L THRIFT EQUIPMENT ROOM. i% STORE - BOND GROUND WIRE TO MASTER GROUND BAR FOR INTERIOR EQUIPMENT SPECIFICATION FOR FACILITY GROUNDING, THE NEC AND LOCAL CODE REQUIREMENTS. - BOND GROUND WIRE TO AC POWER SERVICES AND SURGE ARRESTOR IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR FACILITY EXISTING STAIR FROM GROUNDING BASEMENT 3. #2 AWG STRANDED, INSULATED COPPER WIRE MAY BE USED IN LIEU OF SOLID BCW FOR BONDING DEVICES FROM INSIDE EQUIPMENT ROOM TO THE EXTERIOR GROUND RODS. FOR ELECTRICAL AND GROUNDING SYMBOLS AND ABBREVIATIONS SEE DETAIL 500 SHEET E-2 . ZN so4 NEW GROUND ROD ORIENTAL AVENUE f l cADWELD CONNECTION, ( YP) 514 0 TELCO/ELEC PLAN s NEW THROUGH WALL EXHAUST FAN TO -� o' 2' 4' e' - REPLACE EXISTING WINDOW UM°=E1 @ BASEMENT LEVEL NOTE; NORTH z I-F ! F THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. o > uo AEI - 1�4"-1'-0" LTR0.S1 0 �cA"'"NTS #2 AWG STRANDED INSULATED (INSULATION TO BE UV RESISTANT) OR BARE, SOLID, INSPECTION WELL/W COPPER TINNED COPPER WIRE, TYR. 2 PER _y GROUND AND TEST LOOP r- CABINET RU sos TB Nc TVSS PANEL 4 c FOR SURGE SUPPRESSOR NO z ALARM, CONNECT TO COMMON Nc GROUND WIRE ROUTED FROM INTERIOR ^ AND NORMALLY CLOSED C °S4 GROUND RING HALO TO EXTERIOR GROUND NEW INTERIOR GROUND RING TERMINAL BLOCKS. NORMALLY No ROD HALO, (HALO BY SHELTER MANUF.) UTILITY POWER FAIL CLOSED CONTACTS WILL BE FOR UTILITY POWER ALARM, CONNECT FOR IN NORMAL POWER 5os MASTER GROUND BAR CONDITIONS. CONTACTS WILL a I �' TO COMMON AND NORMALLY CLOS .D OPEN IF TVSS PANEL FAILS. TERMINAL BLOCKS. NORMALLY CL03ED TB CONTACTS WILL BE CLOSED IN NO MAL s POWER CONDITIONS, CONTACTS WIL _ OPEN IF UTILITY POWER FAIL. NOTE: TB LOCATED WITHIN PANEL "P1 " s EXISTING STAIR FROM BASEMENT UTILITY POWER FAIL ZN MANUF: POTTER & BRUMFIELD MODEL:# K10P- 11A15- 120 0 4' 8. 16' AND BASE 27E487 1/4"=1'-0" UTILITY POWER FAIL TVSS FAIL ryry EQUIPMENT GROUNDING PLAN NOTE: scALE: N.T.S. 0 SCALE. N.T.S. 4. scA�E. 1 4" = 1'-0' IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH FC PROJECT NO AT&T WILLIAM F. COLLINS, AIA 903 006 201 02-4926 AT&T WIRELESS SERVICES FISHERS ISLAND � �o R��,``'a — " �" °e.� TELCO/ELEC/GROUNDING - QB 5/15/03 ISSUED FOR ZONING AG.JM AF n �r' i 5 PLANS, NOTES AND DETAILS A R C H I T E C T S, L L F 10/50/02 ISSUED FOR REVIEW PL AF n ORIENTAL AVENUE AT&T WIRELESS SERVICES, INC. NO. DAM REVISIONS BY cNz APP'D JOB N0. SITE No. DRAWING NUMBER REV 10-1 TECFWOLOOY DRIVE 9ETAUXET,NY 11733 D2GD4 FISHERS ISLAND, NY 1 1957 VOICE; 631-689-8450 FAX: 631-689-&59 15 EAST MIDLAND AVENUE \ p y PARAMOS, NJ 07652 �F y ,� SCALE: as NOTED DesICNED DRawN: zxx -Or Nc. 24445 903006201 903 006 201 E-3 B 4 DFN=S7V[160,02] DWG 22 H N T SH 6 5 3 2 PSC= REMOVE EXISTING SMOKE DETECTOR COPPER WIRE TEST LOOP GRADE P1 -14 P1 -8 NEW POWER PANEL "P1 " EZ PRECAST CONCRETE INSPECTION PururE HAND HOLE ASSEMBLY WITH UNT.. E% wcDb> NEW CORD REEL CAST IRON FLANGE AND COVER `iio�U(i.` WITH WORD 'GROUND' CAST ? cna'T F2 P1 -10 INTO COVER. r CADWELD - 1 P1 -6 P1 -4 GRADE NEW 4'x 4'x5/8" THICK NEW SMOKE DETECTOR, Fz PLYWOOD TELCO BOARD _ GRAINGER OR EQUAL CADWELD CABLE Til — — ITIi Ili MODEL# 3KN55/57 TO ROD. #2 AWG BCW NEW MOTION SENSOR SOLID, TINNED P1 -7,9 CLEAN SAND GROUND Ex NEW EMERGENCY LIGHT FILL P1 - 11 , 13 � - P1 -12 P1 - 15, 17 THERMOSTAT In GROUND ROD 0 COPPER WIRE COPPER CLAD NEW EXIT SIGN, TYP. a- GROUND RING STEEL 5/8"0 x10'-0" LONG 31. r^F".i.S rya •.ry.:': .0�, � EXISTING STAIR FROM BASEMNET GROUND ROD COPPER CLAD STEEL 3/4" X BASEMENT PLAN 10'-0" LONG. LIGHTING SCHEDULE LAMPS SYM. MANUFACTURER / MODEL # TYPE FIXTURE LAMP N0, MOUNTING HEIGHT REMARKS WATTAGE TYPE WATTS DETAIL @GROUND TEST WELL DETAIL @ GROUND ROD F2 LEGION CAT. # 4304-232-ACP-ESB/EBO-13A FLUOR. 62 F032-T8 2-32 SURFACE/ STEM SURFACE/STEM MOUNTED NARROW WRAP 2 SCALE: N.T.S. O SCALE: N.T.S. ® EX ATLITE CAT XLN 1 8SR2U—BA LED. 2 LED 1 -2 WALL/ CEILING EMERGENCY EXIT SIGN, SHADING INDICATES # FACES, ARROW INDICATES DIRECTION EM ATLITE CAT # 12ACNY2—BA INCAND. 36 12V PAR36 2- 12 WALL/ CEILING 2 HEAD EMERGENCY UNIT N STRANDED TO GROUND BAR ANTENNA CABLE s 1j�2T�24� INSULATED TWO HOLE LONG ENLARGED LIGHTING BARREL LUG TELCO OR POWER CABLES WEATHERPROOFING KIT AND ELECTRIC PLAN N_DTE: 0' 2' 4' 8, METALLIC (SEE NOTE 3) 1 IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH CONDUITBURNDY O SCALE: 1/4"=t '-C" /4"=t '-G" CONNECTOR R CABLE GROUND KIT (CAT# GAR3903TC) #6 AWG STRANDED COPPER GROUND METALLIC CONDUIT WITH POWER OR WIRE (GROUNDED TO GROUND BAR), 4 5 1 TELCO CABLE (SEE NOTE 1 & 2) #6 AWG FROM ANTENNA °3. #6 AWG STRANDED CABLE. CABLE GROUND KIT 7/16 /4 0 INSULATED GROUND N CONNECTION OF CABLE GROUND r 2 '�KK/JJ ° o STRIP INSULATION IN KIT TO ANTENNA CABLE ° ° 0 0 ° o METALLIC AREA OF CADWELD 00 °° ° �o 0 0 ° CONDUIT ° I CADWELD OR BOND #6 NOTES: 3 0° ° 0) ° 1 pg GROUNDING GROUND WIRE TO SAME 0 ° E-4 BUSHING GROUND BAR TO WHICH 1 . DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT j' GROUND CABLE IS ATTACHED. GROUND WIRE DOWN TO GROUND BAR. 000 METALLIC CONDUIT WITH 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR 0 0 000 O QD LEGEND GROUND WIRE RECOMMENDED BY CABLE MANUFACTURER. 0 1 . COPPER GROUND BAR, 1/4" X 4" X 20", NEWTON INSTRUMENT CO. CAT. NO, B-6142, HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. TWO HOLE LUG, TO 2. INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061 -4 BE USED WITH 3. 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT NO. 3015-8 #2 AWG 1:3CW TO4. WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 BUILDING OR GROUND RING/HALO 5. 5/8- 11 X 1 " H.H.C.S. BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012-1 o GROUND WIRE TO GROUND ROD O GAROUND BAR DETAIL 1 CONDUIT BONDING DETAIL 13 DETAIL @ CABLE GROUNDING KIT OS SCALE: N.T.S. SC QNEC PROJECT NO can °tir 02-4926 ATBcT WIRELESS SERVICES FISHERS ISLAND = _ of AT&T ENLARGED LIGHTING/ELECTRIC WILLIAM F. COLLINS, AIA 903 006 201 PLAN AND GROUNDING DETAILS A R C H I T E C T S, L L P10130102/zo/Dz ISSUED FOR Renew PL aE 7 ORIENTAL AVENUE '�� 70.1TECIINOLODYDRIVE SETAUKETav CHK APP'D,NY11733 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. 02fi" '% D NO. DATE REVISIONS � � JOB N0. SITE N0. RAWING NUMBER REV VOICE: 631689-8450 FAX: 6316PARAMuS,59-8459 15 EAST O AVENUE NJ 07652 scale: as umeU Desmrueo DRAWN: xxz 24445 903006201 903 006 201 E-4 A DFN=STV[160,021 .DWG 22 x 34 SIZE 6 5 4 3 2 PSG= 1900 TX/RX 1900 TX/RX NOTES: CELL SITE INSTALLATION NOTES: 1 . ALL MATERIAL ON THE TABLE BELOW SHALL BE PROCURED BY BECHTEL. THE FOLLOWING INSTALLATION NOTES HAVE BEEN COMPILED FROM THE 1 . ALL ANTENNA COAXIAL CABLES AND JUMPERS SHALL BE INSTALLED WITHOUT EXISTING PROJECT DOCUMENTS (I.E. PROJECT SPECIFICATIONS, EQUIPMENT LOOPS AND/OR PIGTAILS. 2. THE CONTRACTOR SHALL NOT EXCEED THE VENDOR DOCUMENTS, ETC.) FOR USE. THESE NOTES SHALL BE UTILIZED FOR CABLE LENGTHS SHOWN ON THE DRAWING THE CONSTRUCTION OF THE CELL SITES TO ENSURE COMPLIANCE WITH THE WITHOUT RF ENGINEERING APPROVAL. PROJECT DESIGN AND SPECIFICATION REQUIREMENTS. 2. ANTENNA COAXIAL CABLE GROUND KITS SHALL NOT BE INSTALLED ON THE 3 LISTED ARE AREAPPROXIMATIONS A. GROUNDING: JUMPER BETWEEN THE ANTENNA AND MAIN LINE CABLE. DUALPOLE SECTOR BASED ON THESE ANTENNA, TYP, LAND LINK PARABOLIC INTENDED TO BE USED FOR ORDERING CABLE. 1 . ALL METAL CONDUIT FOR GROUNDING DOWN CONDUCTORS SHALL BE BONDED N 3. ANTENNA COAXIAL CABLE GROUND KITS SHALL BE INSTALLED AS CLOSE TO ALL CABLE LENGTHS MUST BE V.I.F. T BOTH ENDS. D TO THE GROUND SYSTEM A DISH ANTENNA THE CONNECTOR AS POSSIBLE AT EACH ANTENNA. IF THIS IS NOT FEASIBLE 7/16" DIN TYPE FEMALE 2. GROUNDING CONDUCTORS SHALL BE CONNECTED TO THE MAIN WATER PIPE THE GROUND KIT SHALL BE INSTALLED IMMEDIATELY AFTER THE BEND ON THE CONNECTOR (ANTENN4) 4. COLOR CODE ALL MAIN USING A BURNDY TYPE GAR—TC CLAMP. CABLES AT TWO LOCATIONS: FIRST STRAIGHT RUN OF CABLE. THE GROUND KIT SHALL BE INSTALLED ON TOP JUMPER CABLE 5/8" DIN TYPE "N" NEAR ANTENNA, 3. KOPR—SHIELD ANTI—OXIDATION COMPOUND SHALL BE USED ON ALL STRAIGHT SECTION OF CABLE ONLY AND NOT ON BENDS. MA FEMALE CONNECTOR NEAR EQUIPMENT GROUNDING CONNECTIONS. (IF REQUIRED) (ANTENNA) 4- ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE 4. ANTENNA COAXIAL CABLE SHALL BE INSTALLED TO COMPLY WITH THE 5. ANTENNAS SHALL BE PROCURED AND CADWELD PROCESS. MANUFACTURER'S MINIMUM BEND RADIUS SPECIFIED IN THE FOLLOWING TABLE, INSTALLED WITH DOWNTILT BRACKETSAND THE CONTRACTOR SHALL INSTALL RACEWAY FOR COAXIAL CABLE USING THE HEAVY DUTY CLAMPS SUPPLIED BY ANTENNA 5- ALL CADWELDS SHALL BE INSTALLED USING THE PROPER CONNECTION/MOLD PROPER FITTINGS NECESSARY TO ENSURE THAT THE MINIMUM BEND RADIUS MAIN COAXIAL CABLE MANUFACTURER UNLESS OTHERWISE NOTED, AND MATERIALS FOR THE PARTICULAR CONNECTION AND/OR APPLICATION, REQUIREMENTS ARE MET. POVIDE A DRIP LOOP AT ANTENNA. 6. TOP AND BOTTOM JUMPERS SHALL BE SUPPLIED AND INSTALLED BY THE EQUIPMENT TEE CONNECTION SWEEP CONNECTION POST CONNECTION GROUND BAR O� MAIN COAXIAL CABLE MANUFACTURER. COAXIAL CABLE MINIMUM BEND RADIUS (NEAR ANTENNAS) —aZ ANTENNA POST 7. CONTRACTOR SHALL VERIFY ANTENNA TYPE CADWELD GROUNDING KIT 34 AND AZIMUTH WITH CONSTRUCTION MANAGER rCADWELD CABLE SIZE MINIMUM BEND MINIMUM BEND RADIUS IN E—a PRIOR TO STARTING CONSTRUCTION. MANUFACTURER CABLE TYPE #2 AWG BCW i CADWELD #2 AWG BCW (DIAMETER) RADIUS IN TRAY 4" OR 6" CONDUIT 8. CONTRACTOR SHALL PROVIDE AN #2 AWG BCW SL� AGROUND BAR 509 INDEPENDENT TESTING AGENCY TO PERFORM ANDREWS LDF5-50A 7/8" 10° CONTACT COAX MANUF. GROUNDING KIT 5134 j E—a El-34 (NEAR ANTENNAS) COAXIAL SWEEP TEST AND REPORT, AND ANDREWS LDF6-50 1 1 4" 15" CONTACT COAX MANUF. PROVIDE THE NECESSARY QUALIFIED / PERSONNEL AND EQUIPMENT NEEDED TO 6. ALL BOLTED GROUNDING CONNECTIONS SHALL BE INSTALLED WITH A LOCK GROUND BAR ASSIST IN ANY REPAIRS AND WEATHER WASHER UNDER THE NUT. HARDWARE FOR BOLTED CONNECTIONS SHALL BE ANDREWS LDF7-50A 1 5/8" 20" CONTACT COAX MANUF. (AT EQUIP.) 501 PROOFING. CONTRACTOR IS TO PROVIDE MINIMUM OF 3/8" DIAMETER AND SHALL BE STAINLESS STEEL. BECHTEL WITH A MINIMUM OF 48 HOURS C #2 AWG INSULATED NOTICE PRIOR TO TIME OF SWEEP TEST AND 7. OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISHING A "CHOKE" POINT. 5. ALL ANTENNA COAXIAL CABLES SHALL BE MARKED IN ACCORDANCE WITH THE #2 AWG INSULATED GROUND WIRE FURNISH RESULTS WITHIN 48 HOURS OF GROUNDING WIRE SHALL NOT BE INSTALLED OR ROUTED THROUGH HOLES IN REQUIREMENTS IN BECHTEL ENGINEERING STANDARDS DOCUMENT GROUND WIRE COMPLETION. ALL SWEEP TESTING TO BE COPPER PLATE DONE IN ACCORDANCE WITH SPECIFICATION ANY METAL #24445-801 -3DS—GET-0002-001 SECTION 24. 5 EQUIPMENT GROUND BAR 6. THE CONTRACTOR SHALL ORIENT THE COAXIAL CABLES ON THE ICE BRIDGE TO . 5os 9. ALL INDICATIONS OF NORTH ARE FOR MATCH WITH THE ORIENTATION OF THE COAX ENTRY HATCH PLATE ON THE BASEMENT (AT EQUIP,) E—a REFERENCE ONLY. CONTRACTOR TO VERIFY SHELTER. IN FIELD TRUE NORTH PRIOR TO SECTOR 4 EQUIPMENT ANTENNA INSTALLATION. 7. ONLY ANDREWS GROUNDING KITS SHALL BE USED ON ANDREWS CABLE. THE FOLLOWING IS A LIST OF PART NUMBERS FOR GROUNDING KITS. 6 BOTTOM JUMPER CABLE —A #2 AWG BCW NOMINAL ANDREWS DEPICTS CHOKE POINT (NOT ACCEPTABLE) CABLE SIZE ANDREWS STANDARD LAND LINK ALPHA SECTOR BETA SECTOR GAMMA SECTOR TOTAL (DIAMETER) CABLE TYPE ( ) GROUND KIT TEM ITEM DESCRIPTION AZIMUTH 36. 15' AZIMUTH 70' AZIMUTH 240' AZIMUTH 310' QUANTITY N0. 8, FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUNDING 7/8" LDF5-50A SGL5- 1084 TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX (SEE NOTE 1 ) CONDUCTOR SHALL NOT BE USED. CLIPS OF THE FOLLOWING MATERIALS AND 1 ANTENNA ANDREW ALLGON ALLGON ALLGON ALLGON ALLGON TYPES MAY BE USED TO FASTEN AND SUPPORT GROUNDING CONDUCTORS. 1 1 /4" LDF6-50 SGL6-1084 (SEE NOTE 5) 5+ 1 AS—BUILT SERIAL # P3F-52 7250.03 7250.03 7250,03 7250.03 7250.03 1 5/8" LDF7-50A SGL7-10134 _ MECHANICAL UPTILT 0.06' 0' 0' 0' 0' O' PLASTIC CLIPS ANTTEONNA WNTILT JUMPER 8, SNAP—IN HANGERS USED FOR 7/8" ANDREWS CABLE SHALL BE ANDREWS LDF4-504 LDF4-504 LDF4—SOA LDF4-504 LDF4-504 30 FT SNAP—IN HANGERS. SNAP—IN HANGERS USED FOR 1 1 /4" AND 1 5/8" B 2 (ANDREW) N/A 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2'" (6 FEET) 1 /2" (6 FEET) ANDREWS CABLE MAY BE ANDREWS SNAP—IN HANGERS R EQUIVALENT (LENGTH) ° METAL CLIPS WHICH DO NOT COMPLETELY SURROUND THE GROUNDING HANGERS FROM ANOTHER VENDOR. ATTACHED MALE DIN INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED CONDUCTOR 2A CONNECTOR L5PNM—RPC W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2 (ANDREW) 9. HOISTING GRIPS USED FOR 7/8", 1 1 /4" AND 1 5/8" ANDREWS CABLE MAY MAIN COAX BE ANDREWS OR EQUIVALENT HOISTING GRIPS FROM ANOTHER VENDOR. FOR 1 3 (LENGTH) (1 ) 5/8°0(65') (2) 7/8"065') (2) 7/e"0(72') (2) 7/8"0(72') (2) 7/e"0(85') (2) 7/8"0(85') 758 FT m 5/8" COAXIAL CABLE, A STAINLESS STEEL HOSE CLAMP MUST BE INSTALLED (ANDREW) LDF4.5-50 LDF5— OA LDF5-50A LDF5-50A LDF5— DA LDF5-50A + 65 FT WITH THE HOISTING GRIP. • UNATTACHED FEMALE 9 4 DIN CONNECTOR T.B.D. L7PDF—RPC L7PDF—RPC L7PDF—RPC L7PDF—RPC L7PDF—RPC 10 (ANDREW) STANDARD GROUND BARS SHALL BE FURNISHED AND INSTALLED. THEY SHALL C . MANUFACTURED MATERIAL: UNATTACHED MALE 10. NOT BE FABRICATED OR MODIFIED IN THE FIELD. 5 DIN CONNECTOR T.B.D L4PDM—RPC L4PDM—RPC L4PDM—RPC LdPIDM—RPC L4PDM—RPC 10 ALL GROUND WIRES SHALL BE INSTALLED WITHOUT LOOPS (PIGTAILS) AND 1 . WHEN SPECIFIC MANUFACTURER'S ITEMS ARE SPECIFIED, THEY MAY BE (ANDREW) SHARP BEND RADIUS. ANTENNA JUMPER REPLACED BY SIMILAR, EQUIVALENT ITEMS WITH PRIOR ENGINEERING APPROVAL, LDF4-504 LDF4-504 LDF4-504 LDF4-504 LDF4-504 LDF4-504 36 FT 6 (ANDREW) /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) (LENGTH) B. ANTENNA COAXIAL CABLES (WAVEGUIDE) 7 ID TAG ALPHA 2 ALPHA 1 BETA 1 BETA 2 GAMMA 1 GAMMA 2 NOTE: THE RF TRANSMISSION LINE INSTALLED BETWEEN THE RADIO CABINET, 8 COLOR CODE THREE GREEN ONE GREEN ONE BLUE THREE BLUE ONE WHITE THREE WHITE FURNISHED BY RBS EQUIPMENT SUPPLIER, AND THE ANTENNA CONSISTS OF A TWO GREEN TWO BLUE FOUR BLUE TWO WHITE FOUR WHITE COAXIAL CABLE, SOMETIMES REFERRED TO AS A WAVEGUIDE. ANTENNA SC WE A 1 SCALE: N.T.S. Ec PROJECT No AT&T WIRELESS SERVICES - «_ 02-4926 FISHERS ISLAND "� c 'nom WILLIAM F. COLLINS, AIA 903006201 0 s/ts/w ssued roR zaNiNc Ac.d AE ANTENNA CABLING SCHEMATIC _ A R C H I T E C T S, L L P ORIENTAL AVENUE Qn io/aD/oz issued FOR REVIEW PL i AE Tr Aa_ AND DETAILS , lo-1TECHNOLOGY DRIVE SETAUKET,NY11739 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. NO. DATE REisloes ev cNN APP'o r, 0269" O Job NO. SITE ND. DRAWING NUMBER REV 15 EAST MIDLAND AVENUE \6 I�� VOICE: 631-689.8450 FAX: 631fi89-&159 PARAMUS, NJ 07652 SCALE: As NOTED DESIGNED DRAWN: zxx �� 1� 24445 903006201 903 006 201 E-5 I B 6 4 3 2 DEN=srV[160,021 Dwc 22 x 34 D SIZE 5 PSC,= li —8 Mpg AT &T D AT&T WIRELESS SERVICES , L . L . C . SITE NUMBER : 903 006 201A SITE NAME : FISHERS ISLAND DIRECTIONS DRAWING INDEX REV. TAKE LONG ISLAND EXPRESSWAY(495) EAST TO EXIT 73. CONTINUE ON TO ROUTE 58 EAST, IT WILL TURN PROJECT INFORMATION INTO ROUTE 25 EAST. FOLLOW SIGNS TO TRUCK ROUTE 25 (ALDRICK LANE), TAKE NORTH TO TRUCK ROUTE 25/CR 48 EAST. CONTINUE ALL THE WAY TO THE END. TAKE THE "ORIENT POINT FERRY" TO THE FERRY 903 006 201 T— I TITLE SHEET I TERMINAL IN NEW LONDON, CONNECTICUT. TAKE THE "FISHERS ISLAND FERRY" FROM NEW LONDON, CT. TO SCOPE OF WORK: AN UNMANNED TELECOMMUNICATIONS FACILITY INCLUDING FISHERS ISLAND. DRIVE OUT OF FERRY TERMINAL AND TURN LEFT ONTO GREENWOOD AVE. AT THE END OF TELECOMMUNICATION EQUIPMENT IN BASEMENT AND C' 903 006 201 A— I PLANS AND NOTES I GREENWOOD, MAKE A LEFT ONTO WHISTLER AVE. CONTINUE ON WHISTLER AVE. UNTIL YOU GET TO RELATED ANTENNAS MOUNTED IN STEEPLE. EQUESTRIAN BLVD. MAKE A RIGHT ONTO EQUESTRIAN BLVD. UNTIL IT MEETS WITH OCEAN VIEW DRIVE. SITE ADDRESS: ORIENTAL AVENUE 903 006 201 A-2 ELEVATION, ENLARGED EQUIPMENT PLAN, I CONTINUE ON OCEAN VIEW DRIVE TO NEATHULIE AVE. MAKE A RIGHT ON NEATHULIE AVE. CONTINUE ON FISHERS ISLAND, NY 11957 NEATHULIE AVE. TO ETTRICK ST. AND CONTINUE STRAIGHT ACROSS ORIENTAL AVE. TO OUR LADY OF GRACE AND ARCHITECTURAL DETAILS CHURCH ON EAST SIDE OF ORIENTAL AVE. PROPERTY OWNER: OUR LADY OF GRACE CHURCH PHONE: (631 ) 788-7353 903 006 201 A-3 ARCHITECTURAL DETAILS I VICINITY MAP ADDRESS: ORIENTAL AVENUE, FISHERS ISLAND, NY 11957 903 006 201 A-4 ARCHITECTURAL DETAILS 0 t CONTACT PERSON: BILL „GLENDON, (ATTORNEY) 1 •I k1 �y\,��! 1� � I I I I 903 006 201 E— I ELECTRICAL RISER DIAGIPAMS AND ELECTRICAL NOTES I PHONE: (914) 725-3442 I APPLICANT: AT&T WIRELESS SERVICES, INC. 903006201 E-2 ELECTRICAL DETAILS ANIS NOTES 0 '”` 15 EASE MIDLAND AVENUE 903 006 201 E-3 TELCO/ELEC/GROUNDING PLANS NO-�`�SAND DETAILS SAF PARAMUS, NJ 07652 Y Id, IIF ' A — 11 .F� �y �'„ II LATITUDE: 41' 15' 40" 903 006 201 E-4 ENLARGED GROUNDING DETAILS LIGHTING/ELECTRIC PLAN, AND JI _ ;Y`� LONGITUDE: 72 00' 52"r ;I ELEVATION: 49'-0" AMSL* 903 006 201 E-5 ANTENNA CABLING SCHEMATIC AND DETAILS I socs� ISia allll n • .I JURISDICTION: TOWN Or SOUTHOLD .�. � ;�� TAX I.D. NUMBER: SECTION: 9 BLK: 7 LOT: 1 1 . 1 SI � 1�IIOCAT�O � tl� _ ZONING DISTRICT: R-80 I i.e)I I p„F' II II .I.IIII°1�I�Il�lll�ll�lliltllll, tv �� p1QI(� I�IIiWlll�l�l Ilili�lll�'w�Ir���od�'9II�ul�lllll�lllm11111 CURRENT USE: CHURCH II II �1;1 11 1V PROPOSED USE: CHURCH B DPY ' li ,, " ti a FI I ;II 1 IIII '1 ill Ill ' c � ,/' �'• AYE .� ` 1 ' � ' I .,�, *THE REFERENCED AMSL INFORMATION SHOWN HEREIN HAS BEEN OBTAINED UTILIZING 3—D �I,I�II141, ';I71'llv ' 111r'I h TOPOQUADS TOPOGRAPHIC MAPPING SOFTWARE BY "DELORME ACTUAL ELEVATIONS MAY VARY ACCORDING TO POINTS OF REFERENCE. V \\e• W 1 TN 1. �I�+6ry1aIII ' IIu II I" ' �1,,11;!�VII= TT y� ai SITE QUALIFICATION PARTICIPANTS ifilllllV III I11'III�I' �r/ ;l NAME COMPANY NUMBER �s = i A/E NEIL A. MACDONALD WILLIAM F. COLLINS, AIA ARCHITECTS, LLP (631 ) 689-8450 t1 -S�E471l pp•_Gr } — {/ _ I SAC PAUL PECKENS BECHTEL TELECOMMUNICATIONS (201 ) 294-6717 �s RF SERHAD GUVEN BECHTEL TELECOMMUNICATIONS (201 ) 755-4297 Ishersisland CON GIL VERONESI BECHTEL TELECOMMUNICATIONS (412) 680-0922 l , A LANDLORD N/A N/A N/A FC PROJECT NO FISHERS ISLAND "— Q 07/09/03 ISSUED FOR CONSTRUCTION JM AF TT 'SID Agcy 2-4926 AT&T WIRELESS SERVICES AT&T 06/0.5/03 ISSUED FOR CONSTRUCTION C AF R �`y O WILLIAM F. COLLINS, AIP, 903 006 201 A — Q 5/15/D] ISSUED FOR ZONING AG,JM AF TT TITLE SHEET A R C H I T E C T S, L L ; ' 11; ; ORIENTAL AVENUE Q ID/30/W ISSUED FOR REVIEW PL A u _ 10.1 TECHNOLOGY DRIVE SETAUKET,NY11733AT&T WIRELESS SERVICES, INC. NO. DATE REVISIONS By CHK API p 02694A JOB NO. SITE NO. DRAWING NUMBER REV FISHERS ISLAND, NY 1 1957 15 EAST MIDLAND AVENUE \TR VOICE: 631.689-8450 FAX: 631.689-8459 PARAMUS, NJ 07652 SCALE: AS NOTED DESIGNED DRAWN: PL 24445 903O06201A T- 1 1 DFN=STV[160,021 .DWG 22 z 34 D SIZE 6 5 4 3 2 PSG— NEW SECTOR "A" GENERAL NOTES: ANTENNA MOUNTED BEHIND NEW RF Q �� LINE OF EXISTING 1 . EXISTING STRUCTURE, TRUE NORTH, AND MISCELLANEOUS 1 1 . THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND GABLE ROOF BELOW INFORMATION WERE TAKEN FROM VARIES SOURCES OF MATERIALS ACCORDING TO THE MANUFACTURER'S TRANSPARENT _ Y INFORMATION, I.E.: FIELD MEASUREMENTS, PHOTOGRAPHS SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOUVER PANEL p�Q� J w S AND INFORMATION FROM AT&T. THIS PLAN DOES NOT LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. sss NEW COAXIALIvo o`n �`� REPRESENT AN ACTUAL SURVEY PERFORMED BY WILLIAM F. _ ANTENNA CABLES n IZ-o z Q o COLLINS, AIA ARCHITECTS, LLP OR ANY OTHER THIRD 12. CODE AND STANDARDS: ROUTED FROM NEW = � " z NEW LAND LINK 3 2. THIS PROPOSAL IS FOR THE PLACEMENT OF PARTY. ALL CONSTRUCTION SHALL MEET OR EXCEED ALL AT&T EQUIPMENT PARABOLIC ANTENNA APPLICABLE NATIONAL AND LOCAL CODES, INCLUDING BUT AT&T EQUIPMENT PARABOLIC ANTENNA ROOM AT BASEMENT TELECOMMUNICATIONS EQUIPMENT IN AN EXISTING NOT LIMITED TO THE FOLLOWING: BASEMENT SPACE, AND THE PLACEMENT OF PANEL -BUILDING CODE OF THE STATE OF NEW YORK BELOW EXISTING ACCESS HATCH ANTENNAS IN AN EXISTING UPPER SECTION OF STEEPLE. -NATIONAL ELECTRIC CODE (NEC) TO LOWER STEEPLE -NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) SECTOR "C" BELOW 3. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND -AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) LE MAGNETIC _ INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY -AMERICAN STANDARDS ASSOCIATION (ASA) NORTH DASHED LINES INDICATE AT&T TECHNICIANS. -UNDERWRITERS LABORATORIES UL (3 1 EXISTING WOOD SUPPORT 4. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM -NATIONAL ELECTRIC MANUFACTURES ASSOCIATION (NEMA) NEW SECTOR "C" �I % FRAME SUSPENDED FROM THIS PROPOSAL. eANTENNAS STEEPLE ROOF JOISTS 5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE MOUNTED BEHIND L_— — J� ABOVE NOT PROPOSED. NEW RF EXISTING HORN, TYP. 6. ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE TRANSPARENT OF (4) PERFORMED IN ACCORDANCE WITH THE PROJECT LOUVER PANEL SPECIFICATIONS. BE RESPONSIBLE v LINE OF EXISTING 7 ALL BCPERMITSTOANDSHALL NSPECTIONS REQUIRED FORINSPECTIONS OBTAINING NEW SECTOR "B" w GABLE ROOF BELOW CONSTRUCTION. 2 ANTENNAS MOUNTED CD 8. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING - BEHIND NEW RF a; Q ANY DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. TRANSPARENT LOUVER o�z 9. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS PANEL co N a FROM THE SITE ON A DAILY BASIS. 10. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS NOTE: AND PLAN DIMENSIONS. CONTRACTOR SHALL NOTIFY THE IF THIS SHEET IS 11 " X 17", ENGINEER AND BECHTEL OF ANY DISCREPANCIES PRIOR TO REFER TO ADJACENT GRAPHIC ORDERING MATERIALS OR PROCEEDING WITH CONSTRUCTION. C SCALE. UPPER STEEPLE PLAN `.� 2' ' 6 NORTH 1 scALE. 1 a" = 1 EXISTING i/ UP THRIFT NEW 200 AMP "APPLETON" STORE EMERGENCY GENERATOR RECEPTACLE AT GRADE ABOVE NOTE: NOTE: QEW AT&- 200 AMP ELECTRIC CONTRACTOR TO PROVIDE SITE 'SPECIFIC SIGNAGE IN FIRE STOP ALL CONDUIT AND CABLE PENETRATIONS UB—MET' :R AT GRADE ABOVE ACCORDANCE WITH AWS LIBERTY PROJECT TECHNICAL THROUGH WALLS AND FLOORS AS PER DETAILS 7/A-2 EXISTING STAIR SPECIFICATION FOR SITE SIGNAGE DOCUMENT NO. EXISTING ELECTRIC UTILITY 24445-801 —3PS—A002-00006 METER Al GRADE ABOVE NEW TELCO COAXIAL CABLE ZLZ3��4ROUTED FROM NEW LAND I o LINK PARABOLIC ANTENNA IN STEEPLE ABOVE I i FINISH SCHEDULE B I I NEW COAXIAL ANTENNA ' SPACE o WALLS CEILING I 555 CABLES ROUTED ALONG a WEST NORTH EAST SOUTH REMARKS CEILING ON UNISTRUT I I m MAT FIN MAT FIN MAT FIN MAT FIN MAT HGT I r-- I PAINT EXIST. NEW AREA VCT R GB P GB P GB PGB P GB 7'-9" CEILING ' LEGEND R = 4" RUBBER BASE GB = GYPSUM BOARD VCT = NEW VINYL COMPOSITION P = PAINT I FLOOR TILE, STATIC FREE) NEW AT&T I I EX = EXISTING EQUIPMEI' T ROOM a I FINISHES EXISTING STAIR I I I PAINT COLORS: WALL AND TRIM: 'BENJAMIN MOORE', REGAL AQUAVELVET, OR EQUAL I I tN RUBBER 'ROPPE' 4" OR 6" HIGH RUBBER COVE l -----�J WALL BASE: COLOR: BLACK #00 FLOORING: 'ARMSTRONG', IMPERIAL TEXTURE ORIENTAL AVENUE 12" X "CLASSIC WHITE° 12' X 12" X 1 /8" V.C.T. PARTIAL BASEMENT PLAN 0' 2.66' 5.33' 10.66' NORTH FINISH SCHEDULE A NOTE: 2 scALe 3 16 = 1'-0 - IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. 6 s"=1'-a„ scALE: N.T.S FC PROJECT NO o a 0 -4926 AT&T WIRELESS SERVICES FISHERS ISLAND AT&T 0 /09/03 ISSUED FOR CONSTRUCTON JM AF IT �(rG _ Q 066/05/03 ISSUED FOR CONSTRUC110N GJ PF Ti _ W I L L I A M F. COLLINS, AIA 903 006 201 A �� s/1s/D3 Issu6D FOR ZONING AO,JM AF TT l= `'' PLANS AND NOTES A R C H I T E C T S, L I. P ORIENTAL AVENUE � LS�LE: lapo/as ISSUED FOR REVIEWPL AF TTo1xECEsocoornElvE saxnuxEr, Nru133 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. 0269% JOB NO. sITE No. DRAWING NUMBER IREVDATE REWSIONS DY LHN APP'D j�VOICE: 634fi89-8450 FAX: 631-689-Ba59 15 EAST MIDLAND AVENUE nrPARAMUS, NJ 07652 AS NOTED DESIGNED DRAWN: PL 24445 903006201 A A- 1 DFN=sTV[160,021 DWG 22 x 34 D SIZE 6 5 4 3 2 PSD_ : NE AT&T 200 AMP SUB-MET R NEW 200 AMP "APPLETON" E-1 MOUNTED ON EXTERIOR FACADE OF EMERGENCY GENERATOR 01 , BUILDING BESIDE EXISTING ELECTRIC RECEPTACLE MOUNTED TO METER AT GRADE -9 1 /4„ EXTERIOR FACADE OF ATTACH WITH EXISTING ELECTRIC METER BUILDING AT GRADE (2) #14X3" LONG GALVANIZED WOOD SCREWS OR 3 8" GALVANIZED LAG MOUNTED TO EXTERIOR FACADE � �, wa.�,; NEW AT&T 200 AMP i / OF BUILDING AT GRADE '' it" POWER PANEL E—i / BOLTS FOR USE IN WOOD FRAMING EXISTING LOUVERS TO BE NEW 200 AMP AT&T EXISTING ELECTRICAL PANEL / c REPLACED WITH NEW RF _; AND PLYWOOD BACKBOARD M — UNISTRUT P1000 (OR EQUAL) 1 5/8" x 1 5/8" TRANSPARENT LOUVER DISCONNECT u5 -D PANELS, TYP. OF 3 NEW OA ATE A EXISTING SMOKE DETECTOR n o WITH HOT-DIPPED GALVANIZED FINISH O s55 - j— I TO BE REMOVED AND / oo — UNISTRUT PIPE/CONDUIT CLAMPS P2558 OR LOCATIONS AT UPPER - CABLES ROUTED ON e EUYuSREPLACED WITH NEW a o EQUAL STEEPLE UNISTRUT UP THROUGH W DMA SMOKE DETECTOR � o� PIPEOR CONDUIT FLOORS TO STEEPLE I - - EXISTING DOOR AND DOORSECTOR "B" ANTENNAS I - ABOVE F uRE�MOUNTED BEHIND NEW RF EXISTING CEILING SYSTEM " I N KIATFRAME TO BE REMOVED AND TRANSPARENT LOUVER REPLACED WITH NEW 3'-0" is1 PANELS, TYP. OF 5 TO BE REMOVED AND Lc mere fFIRE-RATED DOOR AND � EXISTING WALL OR CEILING REPLACED WITH NEW FRAME, TYP.ALL SECTORS1 1 2" HR. FIRE RATED > . " INOTE: / DASHED LINES INDICATE SECTION TYPICAL FOR WALL OR CEILING36'-4"± A.G.L. CEILING � r0 OF EXISTING DOOR JAMB, WALL MOUNTED APPLICATIONS.RAD. CL OF ANTENNA NEW THROUGH WALL A AND DOOR TO BE REMOVED I- ___- EXHAUST FAN TO 230'- A.G.L. --- REPLACE EXISTINGEXISTING WOOD PLANK FLOORING ELOOR OF UPPER - WINDOW AND FRAME TO BE REMOVED. SEE NOTE THIS STEEPLE — CiA3DETAIL DETAIL @CONDUIT SUPPORT NEW 48"x48" TELCO - _ -BACKBOARD DASHED LINE INDICATES NEW 3'-0" LOUVERED9 -7"± A.G.L. — DOOR cABWN ;t' EXISTING CHURCH ORGAN FLOOR OF LOWER A iPUMP TO BE RELOCATED UNISTRUT P1000 X 12" ATTACH WITH STEEPLE WITHIN ROOM IF NECESSARY (2) 3/8"0 EXPANSION ANCHOR REMOVE EXISTING ALUMINUM �THRIFTM (MIN. EMB. DEPTH = 1 5/8") NEW COAXIAL ANTENNA - ------------ - a CABLES ROUTED ON - __ SCREEN DOOR STORE V 2 UNISTRUT P1000 X 12" ATTACH WITH 2 UNISTRUT UP THROUGH a W EXISTING STORM DRAIN TO BE 2 / 1 '-4' NEW FULL HEIGHT 2 HR. CLEARED OF DEBRIS AND TO O FIRE-RATED a (2)#14 X3" LG. GALV. WD. SCREWS FLOORS FROM NEW AT&T BE MADE FUNCTIONAL SHAFT WALL, TYP. OR 3/8" GALV. LAG BOLTS FOR EQUIPMENT ROOM IN o USE IN WOOD FRAMING BASEMENT TO UPPER EXISTING STAIRS TO STEEPLE ANTENNAS DASHED LINES INDICATE SECTION =A EXTERIOR GRADE FROM OF EXISTING DOOR JAMB, WALL ANTENNA CABLE WITH ± A.G.L. - NEW AT&T EQUIPMENT AND DOOR TO BE REMOVED, TYP. APPROPRIATE SIZE TO EQUIP. -- = ROOM ROOM CLG. -- -- - EXISTING HAND STANDARD HANGERS J 0'-0"± RAILING GRADE r „n;,,,,,. , : NOTE: CONTRACTOR TO REMOVE EXISTING WOOD FLOORING NOTE: NOTE: MASONRY WALL F.= . SYSTEM DOWN TO EXISTING CONCRETE SLAB. EXISTING -2°± B.G.L. BELCW GRADE ENTRANCE TO CONCRETE SLAB TO BE PATCHED, REPAIRED AND IF THIS SHEET IS 11 " X 17", STUD WALL SUPPORT SPACING: 4'-0" O.C. MAX. (MIN. 6 THICKNESS) NEW AT&T EQUIPMENT ROOM MADE LEVEL PRIOR TO PLACEMENT OF NEW VINYL REFER TO ADJACENT GRAPHIC EQUIP. ROOM F.F.E. N B, SEMENT SCALE. COMPOSITE TILE FLOORING. NORTHEAST ELEVATION < ENLARGED BASEMENT EQUIPMENT PLAN 0' 1.33' 2.66' 5.33' NORTH #5SCALE!CABLE SUPPORT 2 SCALE: 3 8" = 1'-0" 3/8"=1'-0" 3 1 /2" CAULK BOTH SIDES EXISTING SUB AND 7 5/8 FINISH FLOOR V.I.F. EXISTING BRICK WALL WITH 3M FIRE BARRIER EXISTING MASONRY WALL CP 25WB CAULK. EXISTING WOODPROVIDE CLEARANCE FOR 3 1 /2" MINERAL WOOL PACKING. JOISTS, V.I.F. DAMPER EXPANSION ON BOTH WOOD JOISTS ABOVE NEW R-30 BATT SIDES AND TOP AS REQUIRED '3M' MOLDABLE PUTTY MIN. 1 " THICK FLUSH NSULATION, TYP. WITH WALL SURFACES. MIN. 1 /2" THICK CR RUNNERS TOP AND CROWN AROUND PENETRATING ITEM. REFER TO BOTTOM, TYP. EXPANSIONMANU FACTURES RECOMMENDED INSTALLATION BOLT TO SLAB AT 24" O.C. -.? \ INSTRUCTIONS. 17 (2) LAYERS 1 /2" ----- P METALLIC PIPE/CONDUIT OR SLEEVE GYPSUM BOARD PANELS FIRE-CODE "C" - 3M' MOLDABLE PUTTY. Ln FIRESTOPPING @ PIPE PENETRATIONS 1 " DEPTH MIN. 1 /2" 1 " GYP. BD. LINER PANEL CROWN, TYP. BOTH 1 1 /2" USG 25 GA. C-H SIDES _ STUD AT 24" O.C. NEW 1/2" GYPSUM BOARD, OSHA APPROVED MOTOR SIDE GUARD EXISTING WOOD FIRE-CODE "C' 4" RUBBER BASE CORE JOISTS, TYP. 1 ( 1 ) NEW RC-1 RESILLIENT 2" GALVANIZED ANGLE IRON / FINISH FLOOR SLAB CHANNEL AT EVERY 24" O.C.J. SUPPORTS WITH CONCRETE ANCHOR EXPANSION BOLTS NEW METALLIC L` SLEEVE 1 WALL TYPE 1 CEILING TYPE NEW STORM PROOF GRAVITY P] 2 HR. RATED SHAFT WALL-UL DES U438 T 1 1 /2 HR. RATED CEILING-UL DES L51C LOUVER WITH BIRD SCREEN O ANTENNA CABLES, (AGAINST EXISTING WALL) ° ~ TYP. 2HR. SHAFT WALL /�M 1 1 /2HR. CEILING O EXHAUST FAN/FIRE DAMPER ODETAILS @ FIRESTOPPING f 'r / scALE: 1 1 2 = 1 ^o / SCALE: 1 1T2" = 1 O 6 SCALE: 1 1/2"=V-0" 7 _ _ _ FIRESTOPPING @ CABLE THROUGH FLOOR SLEEVE �/ FG PROJECT NO Q- Cs, 2-4926 AT&T WIRELESS SERVICESFISHERS ISLAND DE WILLIAM F. COLLINS, AIi', sos oos toy A AT&T 07/00/03 ISSUED FOR CONSTRIJUION JM AF n Q os/os/o3 ISSUED FOR CONSTROCTION cd AF n ' V ELEVATION, ENLARGED EQUIPMENT PLAN ARCHITECTS, L L _' AND ARCHITECTURAL DETAILS ORIENTAL AVENUE � A TO/JD/02 ISSUED FOR RENEW PL AF n r tat TECHNOLOGY DRIVE SETAUXET,IVY 11733AT&T WIRELESS SERVICES, INC. FISHERS ISLAND, NY 11957 NO. DATE REVISIONS BY CNK APP'D v 026044 JOB NO. SITE N0. DRAWING NUMBER VOICE: 631-689-8450 FAX: 631-689-8459 15 EAST MIDLAND AVENUE REV PARAMOS, NJ 07652 SCALE: AS NOTED DESIGNED DRAWN. PIL \' np ^ 24445 903006201 A A-2 1 6 4 3 2 UFN=STV[160,02] .DWG 22 x 34 D SIZE 5 PSG= NEW SECTOR "A" LINE OF NEW COAXIAL ANTENNA <6> EXISTING GABLE 555 NEW COAXIAL ANTENNA -] 555 CABLES ROUTED UP ON ANTENNA ROOF BELOW —5 - CABLES ROUTED UP --- ''m UNISTRUT THROUGH THROUGH CEILING ON o EXISTING FIRST FLOOR EXI IN EXISTING HORN, TYP. EXISTING LOUVERS TO BE UNISTRUT TO EXISTING - STORAGE ROOM CEILING STORAGE ROOM REPLACED WITH U FIRST FLOOR STORAGE 2 555 NEW COAXIAL FUTURE NEW AT&T AND LOWER STEEPLE EXISTING TRANSPARENT LOUVER ROOM ABOVE I °MTs ' EQUIPMENT AREA ABOVE SANCTUARY ANTENNA CABLES PANELS, TYP. OF (3). �1LMA O FlCDMA ROOM AREA ROUTED UP FROM I,., ;,. ! SEE DETAIL 2, THIS NORIA LOWER STEEPLE pLTRASREI - BELOW ON UNISTRUT i,7 = -� _ '; ' SHEET LCABIN TO NEW AT&T �I;.��',,_- _ NEW LAND LINK 3\ 5 AA ANTENNAS MOUNTED l II PARABOLIC ANTENNA/ EXISTING STATUES, ID TO INSIDE FACE OF r-- ��— EXISTING EXISTING CONTRACTOR TO RELOCATE EXITING TYP. OF (3) UPPER STEEPLE THRIFT WORSHIP HORN TO ACCOMMODATE POSITIONING � AREA �_ OF NEW PARABOLIC ANTENNA t STORE �, II'v i / II <6> NEW SECTOR "C" CONTRACTOR TO PROVIDE CONTINUOS 2x6 WD. EXISTING ACCESS I II a ANTENNAS BRIDGING BETWEEN FLOOR JOISTS WITHIN HATCHED ry HATCH TO STEEPLE Li_ _Jj AREA, AND SOLID BLOCKING AT BEARING POINTS. ABOVE DASHED LINE INDICATES EXISTING WOOD PATCH ROOFING MEMBRANE AS REQ'D FRAMING MOUNTED O 0 FROM CEILING ABOVE LINE INDICATES D. A NEW SECTOR "B" HIGH POINT IN 4 ANTENNAS SLOPED FLOOR z EXISTING ACCESS NOTE: HATCH TO LOWER CONTRACTOR TO STEEPLE BELOW EXISTING STAIRS EXISTING STAIRS RELOCATE AND OR FROM BASEMENT FROM BASEMENT REPOSITION EXISTING LINE OF SN HORNS AS REQUIRED. EXISTING GABLE ROOF BELOW BASEMENT PLAN FIRST FLOOR PLAN UPPER STEEPLE PLAN ANTENNA CABLE ROUTING PLANS NOTE: 2 a' i NORTH 1 SCALE: 1/4 = 1 -o F THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NEW W'x4"X1 /2" NOTES: GALVANIZED STEEL RIGGERS TO DELIVER ANTENNA THROUGH LOUVER 9 1 /4" ANGLE, TYP. SECURED 1 ROUGH OPENING AT TIME OF LOUVER REPLACEMENT. 5'-0" WITH 3/8" LAG BOLTS, 0'-6° 1 '-5' 2'-0" BOLT AT EACH EXISTING 1 '- 11 1 /4" 2'_0" 2'-7 1 /2" 2'-0" V-11 1 /4" NEW ' S6' TRIPOD, A STUD LOCATION WHERE MICROFLECT' OCCU 6 PART#91013 NEW ! I"x4"X1 /2" GALVANIZED STEEL Cf ANGLE. SECURED TO \� A 1 '-6" 9"x4"x1 /2" ANGLE WITH 1 '-6" NEW LAND LINK 5 V.I.F. -- 1 /4" CONTINUOUS WELD, V.I.F. PARABOLIC ANTENNA, TYP. "ANDREW" ----- -- 1 /2"¢ GALVANIZED —77 77 -- — �y — FPART#P35-52 \ . v dl STEEL U-BOLT, TYP. �� ��; , �� 6 ' NEW PANEL ANTENNA, , SEE DET. 1 /E-5 � hp' , EXISTING WOOD FRAMING1 ,L1 v�IDF MOUNTED FROM CEILING. EXISTING HORN, TYP. OF (4) t � fjGt -- — %, " ", — `n HORN NOT SHOWN FOR t ,I s � _ I REASONS OF CLARITY u7 3a , '$, 1; m H�1�{ c0 N j' ­Ji; 'I EXISTING WOOD FRAMING, �,rrs k �i NEW RF TRANSPARENT TYP., V.LF. bs "Ir LOUVER PANELS, TYP. NEW 2-3/8" O.D. „aK,i —I ilsllOF (3) SEE NOTE ,` �' n1'� THIS DETAIL GALVANIZED STEEL PIPE TYP.- 5/8„ DIA. COAXIALI'E'' — NEW ANTENNA RF TRANSPARENT ONUNISTRUTTED ALONG LOUVI-R PANELS, TYP, INTERIOR WALL OF —OF (3), SEE NOTE THIS - - - CD oe 555 UPPER STEEPLE, TYP. DETAIL_ BOLT AT EACH EXISTING 7/8"0 COAXIAL ANTENNA ° STUD LOCATION WHERE CABLCS ROUTED ON OCCURS UNISTRUT ALONG 555 INTERIOR WALL OFA UPPED STEEPLE, TYP. 4'- 10 BOLT AT EACH EXISTING A 6 - 10 CONTRACTOR SWI NECESSARY HI PROVIDE MS STUD LOCATION WHERE NOTE: R.O., TYP. TYPICAL SECTION TO MAKE NEW "S6" r,-,TYPICAL NOTES: A TYPICAL SECTION OCCURS NOTES: A TRIPOD PLUMB, V.I.F. BFOR STANDARD PANEL ANTENNA MOUNTING DETAILS EXISTING CEILING MOUNTED B TYPICAL ELEVATION CONTRACTOR RESPONSIBLE FOR ANTENNA MOUNTING DETAIL, WOOD FRAME AND HORNS OF RFATRANSPARENTTPANELION S. 3 PARABOLIC ANTENNA MOUNTING DETAIL SEE DETAIL 2 THIS SHEET. 2 SCALE: 3 4 = 1 -o NOT SHOWN FOR CLARITY. _ FC PROJECT NO AT&T WIRELESS SERVICES JM AF n �Eo R ''� 0 -4926 FISHERS ISLAND AT&T 06/09/03 ISSUED FOR CONSTRUCTION �� \ _ 06/05/03 ISSUED FOR CONSTRUCTION GJ AF TT G'! WILLIAM F. COLLINS, AIA 903 006 201 A QB 5/15/03 ISSUED FOR ZONING AG,JM AF y,: ARCHITECTURAL DETAILS A R C H I T E C T S, L L P ORIENTAL AVENUE m/3D/O2 IssucD FOR REVIEW PL AF Tr 1 , !,' AT&T WIRELESS SERVICES, INC. N0. DAM REVISIONS BY CHK APP' 9 026944 t OB N0. SITE N0. DRAWING NUMBER REV 10-1 TECHNOLOGY DRIVE SETAUKET,NY 16133 FISHERS ISLAND, NY 11957 15 EAST MIDLAND AVENUE \' C VOICE: 631-689-8450 FAX: 63Ifi89-&G59 Oma ' 24445 903006201A A-3 1 PARAMOS, NJ 07652 SCALE: AS NOTED DESIGNED DRAWN: PL p p DFN=SN[1 60,021 .DWG 2L $ 34 � c[ 4 3 2 PSG- 6 5 EXISTING STUD WALL SEE SCHEDULE SEE SCHEDULE EXISTING MASONRY WALL N N NEW 2 HR. SHAFT WALL DOOR AND HARDWARE SCHEDULE OR AND HARDWARE SCHEDULE HOLLOW METAL DOOR \` NEW 1 /2" GYPSUM FRAME BOARD ON RESILIENT DOOR #1 : 3'-0" x 6'-8" x 1 3/4" 16 GAUGE 24^ DOOR #2: 3'-0" x 6'-8" x 1 3/4" 16 GAUGE CHANNEL INSULATED METAL, 1 1 /2 HR. "B" INSULATED METAL WITH 24"x24° STORM HOLLOW METAL DOOR AS \\ \ LABEL. PROVIDE UL RATED WIDE-ANGLE PROOF LOUVER W/ BIRD SCREEN. PAINT SCHEDULED (FISHEYE) PEEPHOLE. PAINT SUMMIT SUMMIT GRAY. THRESHOLD BELOW GRAY. FRAME: 3'-0" x 6'-8" 16 GAUGE HOLLOW FRAME: 3'-0" x 6'-8" 16 GAUGE HOLLOW METAL 1 1 /2 HR. FPSC. CAULK WATER nJAMB (HEAD SIMILAR) nJAMB (HEAD SIMILAR) w METAL 1 1 /2 HR. "B" LABEL. CAULK w N TIGHT AROUND EXTERIOR PERIMETER. WATER TIGHT AROUND EXTERIOR U J J PAINT SUMMIT GRAY. PERIMETER. PAINT SUMMIT GRAY. HINGES: 1 1 /2 PAIR 4 1 /2"x4 1 /2"xSTD. EXISTING STUD WALL ww HINGES: 1 1 /2 PAIR 4 1 /2"x4 1 /2"xSTD. o WEIGHT, BALL BEARING HINGES WITH BEYOND u2„ & 2„ WEIGHT, BALL BEARING HINGES WITH 2„ 2' CONCEALED SETSCREW TO LOCK IN HOLLOW METAL FRAME -- CONCEALED SETSCREW TO LOCK IN HINGE PIN. STANLEY NO. FB8191 . BEYOND w HINGE PIN. STANLEY NO. F1313191 . LLJ HOLLOW METAL DOOR AS NEW VCT FLOORING 3 V) bi DOOR #2 SCHLAGE L-SERIES LOCK AND DEAD DOOR #1 SCHLAGE L-SERIES LOCK AND DEAD LOCKSET: BOLT ASSEMBLY, MODEL# L94P. SCHEDULED — 1 LOCKSET: BOLT ASSEMBLY, MODEL# L94P. 3 CLOSER: LCN 4010 SWEEP WITH RAIN DRIP CLOSER: LCN 4010 STOP: CANVAS OR RUBBER COVERED CHAIN THRESHOLD SET IN STOP: STEEL BRUSHED CHROME FINISH STOP. SEALANT RUBBER FLOOR STOP . WEATHER- WEATHER- STRIP: VINYL BULB TYPE AT HEAD AND JAMBS. THRESHOLD STRIP: CONTINUOUS SMOKE PROOF GASKETING. SILL UTHRESHOLD U 2 4 PROT: BRUSH TYPE. THRES- HOLD: ALUMINUM THRESHOLD IMBEDDED IN DOOR #1 DOOR #2DOOR #1 DOOR #2 SEALANT. SCALE: 1 1/2"=1'-0" SCALE: 1 1/2"=1'-0" SCALE: 3/4=1'-0=1'-0' SCALE. 3/4"=1'-0' DOOR DETAILS 1 SCALE: AS NO TED ANTENNA MFG: DECIBEL PART NO. : 731DG65V1EXM o — 1 MOUNTING BRACKET MFG: DECIBEL PART NO. : DB380 (INCLUDED) i 7" 1 1 FRONT VIEW SIDE VIEW TOP VIEW ANTENNA DETAIL L SCALE. iT=1 -0 Q _ FC PROJECT NO AT&T ��a�D A'-c 02-4926 AT&T WIRELESS SERVICES FISHERS ISLAND �,5 °ER ��� 903 006 201 A WILLIAM F. COLLINS, AIA os/os/m ISSUED FOR CONSTRUCTION w AF Tr 'U ' � ARCHITECTURAL DETAILS A R C H I T E C T S, L L P A 10/X1/02 ISSUED FOR REVIEW PL AF TT ORIENTAL AVENUE 10-1 TECHNOLOGY DRIVE SETAUKET,NY 11733 AT&T WIRELESS SERVICES, INC. NO. DATE REVISIONS Rr CHH APP'D V y\ 026944 / JOB NO. SITE NO. DRAWING NUMBER REV FISHERS ISLAND, NY 1 1957 15 EAST MIDLAND AVENUE F VOICE: 631-689-8450 FAX: 631-689-8459 PARAMUS, NJ 07652 <- !" SCALE: A9 NDTED DESIGNED DRAWN: PL 24445 903006201 A A-4 0 6 5 4 3 DFN=STV[160,02] DWG 22 k 34 SIZE PSC= NOTES : LI : 0 0 1 . SUBCONTRACTOR SHALL PROVIDE 200AMP, THREE PHASE, 120/240 VAC, 60HZ SERVICE FOR AWS SITE. E ALL CONTACTS TO ALARM CONTACTS E CONTINUITY WHEN TVSS COMMERCIAL GENERATOR 2. SUBCONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY BEFORE THE START OF CONSTRUCTION. POWER CONDUIT SHALL BE PROVIDED T IS NORMAL AND LOSS 0 11 —COM 11 —COM AND INSTALLED PER UTILITY REQUIREMENTS. NTINUITY WHEN CIRCUIT 1 2 4—NO 4—NO 0 Q 0 12—NC3. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY PANEL MANUFACTURER. DUCTOR SHALL HAVEL3 . PLTC0O04. ALL SERVICE EQUIPMENT AND INSTALLATIONS SHALL COMPLY WITH THE N.E.C. AND UTILITY COMPANY AND LOCAL CODE REQUIREMENTS. TION.E AND STORE ANY05. SUBCONTRACTOR SHALL INSTALL SUFFICIENT LENGTHS OF LFMC INCLUDING ALL CONDUIT FITTINGS (NUTS, REDUCING BUSHINGS, ELBOWS, CONDUCTORS. COUPLING, ETC) NECESSARY FOR CONNECTION FROM THE NEMA BOX TO THE INTERIOR BTS CABINET. 6. SUBCONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE EQUIPMENT WITH FAULT CURRENT RATINGS GREATER THAN THE AVAILABLE FAULT 0 0 CURRENT FROM THE POWER UTILITY. 7. POWER, CONTROL AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG AND LARGER), 600V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90-C (WET AND DRY) OPERATION; LISTED OR LABELED 0 0 FOR THE LOCATION AND RACEWAY SYSTEM USED. 8. CUT, COIL AND TAPE A 5 FOOT PIGTAIL FROM END OF LFMC FOR TERMINATING BY BTS EQUIPMENT MANUFACTURER. 0 O o O DETAIL 1022, SHEET E-2 9. SUBCONTRACTOR SHALL FURNISH AND INSTALL A NEMA 3R ENCLOSURE WITH INTERNAL 5/8" THICK PLYWOOD BACKBOARD. SUBCONTRACTOR 0 O 0 ONCNC NC NC 21 22 SHALL FURNISH AND INSTALL SURGE PROTECTION DEVICES (BY ATLANTIC SCIENTIFIC; ZONE BARRIER SERIES; PART NO. 90700 WITH MOUNTING DIN RAIL PART NO. 21607). BOND SURGE PROTECTION DEVICE DIN RAIL TO THE ENCLOSURE WITH #6 AWG INSULATED WIRE 0 0 22-24AWG SOLID (REFERENCE STANDARD DETAIL 1015). BOND ENCLOSURE TO THE SITE GROUND RING OR BAR WITH #2 AWG COPPER WIRE. 0 0 (SEE NOTE 3) 10. SUBCONTRACTOR SHALL PROVIDE 6"x6"x4" (MIN.) NEMA 3R STEEL ENCLOSURE AND MOUNT TO CONDUIT RACK AT REAR OF CABINET. 0 COMM PWR FAIL KD® &GENERATOR RUN rn LEGEND : NEW LAND LINK PARABOLIC ® & cn ® MI — MECHANICAL INTERLOCK ANTENNA (s) 41 TVSS FAIL ® � cN i RU — RELAY TO MONITOR UTILITY POWER N RG — RELAY TO MONITOR GENERATOR POWER NEW 30"x30"x10" TELCO AC SERVICE ENTRANCE ]RR 4, (s) BOX WITH GFI RECEPTACLE UTILITY 120/240VAC e� CABINET ALARM ASSIGNMENTS EAST COAST AC SVC ENTRANCE CABINET FED FROM NEAREST 200A 10 3W OG CTB SERVICE. scnLE: N.Ts. ALARM TERMINAL BLOCK ASSIGNMENTS 2" CONDUIT WITH 4 PR. TELCO BOX (SEE: NOTE 9) CAT 5 CABLES & OA NEW 2.5" C WITH 4-4/0 1 6 THHN CU WITH A 66—B3— 30 BLOCK PULLSTRING E1 . COORDINATE ALL NEW WORK WITH LIPA E5. PROVIDE AND INSTALL SURGE ARRESTOR REF. DETAIL# 10: 2, SHEET FOR THE ADDITION OF THE NEW 200 AMP INNOVATIVE TECHNOLOGY INC., IT E-2 FOR ALARM ASSIGNMENT HwH NOTE cEN NOTE SERVICE. RELAY ALARM CABLES SUB—METER NOTE E2 REC Eg PROTECTOR #PTE/80/PTX080. #2 AWG GROUND FROM PANEL TO 200A 0 (BY SUBCONTRACTOR) E1 GRADE E2. PROVIDE AND INSTALL NEW 200 AMP E6. PROVIDE AND INSTALL NUMBER 2 COPPER CONDU 'TOR _ ULTRASITE CABINET, SUB—METER GROUND AND 3/4" x10' GROUND RODS SEE NOTE 8 4—PAIR #22-24 AWG IN NOTE: E3. PROVIDE AND INSTALL NEW 200 AMP, 3 FOR NEW SERVICE. MAXIMUM RESISTANCE 3/4" CONDUIT 120/240VAC 200A 10 3W USE THREADED NOTE POLE FUSED DISCONNECT SWITCH WITH TO GROUND SHALL BE 5 OHMS. PROVIDE 1 /2" LFMC COUPLINGS ONLY NOTE E4 SOLID NEUTRAL RATED FOR SERVICE AND INSTALL ADDITIONAL GROUND RODS 3/4" LFMC SEE NOTE 5 200A FUSED GROUND PIPE AT E3 ENTRANCE EQUIPMENT. FUSE WITH THREE NOT LESS THAN 6' APART TO MEET EACH END NEW BUSSMAN FRN 200 FUSES. p DISCONNECT URG ANE MINIMUM GROUNDING REQUIREMENTS. 00 A REST R P1 E4. PROVIDE AND INSTALL NEW SQUARE "D" E7. PROVIDE AND INSTALL BRANCH CIRCUIT swTCH A NEMA 3R, SURFACE, 20" WIDE CABINET WIRING TO GFCI RECEPTACLE, FIRE I 200AMP, 1 -0 MODEL# NQOD43OL225CU PANEL P1 . DAMPER GENERATOR RECEPTACLE NOTE NOTE PANEL SHALL BE RATED 200A, 120/208 / FAN, NOKIA CABINETS, ETC. PER E / OWNERS REQUIREMENTS. COORDINATE WITH _ E6 E5 VOLT, 3 PHASE WITH A 200A MAIN SEE U R NOTE BREAKER, ALL COPPER BUS, BOLT ON PROJECT MANAGER AS NECESSARY. NOTE 10 SEE DETAIL 1023 FOR--,, 200 _ 200A BASEMENT E7 BREAKERS AND DOOR IN DOOR HINGED E8, PROVIDE AND INSTALL 200A, 3 PHASE, 4 NOKIA I NOKIA I ALARM TERMINATORS MI N G CONSTRUCTION. SEE DETAIL 923A, THIS WIRE PIN AND SLEEVE GENERATOR ULTRASITE I POWER NEW RISER DIAGRAM SHEET. RECEPTACLE. E ADJA200ACL SHALL SERIES WITH CABINET CABINET 40 MOUNTING BOX. LOCATE RECEPTACLE ON (BACK) (BACK) I 20OAMP, 3—PHASE ELECTRICAL RISER IA RAM EXTERIOR OF SHELTER AT A LOCATION 1 " CONDUIT WITH (2) 2 DISTRIBUTION PANEL \ / scALE: N.ts' APPROVED BY PROJECT MANAGER. PAIR, CAT 5, UTP CABLE 40 3/4" LFMC I FOR TELCO SERVICE (REF. ELECTRICAL NOTES: DET.# 1016, SHEET E-2); 40 15A #2 AWG GROUNDING (1 ) 26 CONDUCTOR 1 . CONDUIT ROUTINGS ARE SCHEMATIC, CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. ELECTRODE CONDUCTOR EXTERNAL ALARM CABLE 2, THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF — (REF. DET.# 1020, SHEET CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. E-2) OKA TVSS 3. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS #2 AWG SUPPLEMENTAL, ARE PERMITTED. EQUIPMENT GROUND 4. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. CONDUCTOR 6- 1 /C #8 AWG+ THHN 1 - 1 /C #10 AWG THHN 5. ALL DISCONNECT SWITCHES SHALL BE SIZED AND HAVE NEMA ENCLOSURE AS STATED ON THE DRAWINGS. SWITCHES SHALL BE QUICK MAKE, QUICK BREAK, GENERAL DUTY, HORSEPOWER RATED, FUSES SHALL BE BUSSMAN TYPE RK-1 CURRENT LIMITING, TIME DELAY—DUAL ELEMENT. 030SCINGLE LINE DIAGRAM GREEN INSULATED GROUND 1 " 0 IMC LE: N.T,S. #2- 1 /C 14 AWG THHN 1 - 1 /C 14 AWG THHN 6. RELOCATE AND RECONNECT, AS REQUIRED BY CONSTRUCTION, OUTLETS, LIGHTS, OR OTHER ELECTRICAL EQUIPMENT ENCOUNTERED DURING CONSTRUCTION. EXISTING A GREEN INSULATED GROUND 3/4" CONDUIT ELECTRICAL EQUIPMENT, WHICH IS TO REMAIN BUT IS ON THE SAME CIRCUIT AS EQUIPMENT BEING REMOVED, SHALL BE RECONNECTED AND LEFT IN OPERATING CONDITION. FC PROJECT NO FISHERS ISLAND —�— �D A'" AT&T � 07/09/03 ISSUED FOR CONSTRUCTION JM AF 7 Fry 0 -4926 AT&T WIRELESS SERVICES DER 903 006 201 A a 06/0./0) SSUED FOR CONSTRUCTION GJ AF TT F WILLIAM F. COLLINS AIA ELECTRICAL RISER DIAGRAMS A R C H I T E C T S, L L P � Q 5/15/0.1 ISSUED FOR ZONING gG,JM AF TT ORIENTAL AVENUE 0 Tap9/09 ISSUED FOR REVIEWPL AF "1 * AND ELECTRICAL NOTES 10-1 TECHNOLOGY DRIVE SETAUKET,NY11733 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. VOICE: 631.689-8450 FAX: 631-689-8459 NO. DATE REMSIONS Dr cRN APP'D 9w 026944 O` 15 EAST MIDLAND AVENUE �.�,F .� JOB NO, SITE NO, DRAWING NUMBER REV PARAMOS, NJ 07652 SCALE: AS NOTED DESIGNED DRAWN: PL ^r m I 24445 903006201 A E- 1 1 6 5 4 3 2 DFN=STV[160,021 DWG 22 x 34 D SIZE PSC— INNOVATIVE TECHNOLOGY, INC . TO RADIO CABINET NOTES: (NOKIA/ERICSSON) Tl SURGE SUPPRESSOR 1 . MOUNT S66M1 -50 BLOCK W/89B BRACKET IN TELCO BOX OR ON TELCO BACKBOARD OR IN NEW 3R TRANSIENT VOLTAGE SURGE SUPPRESSOR ATLANTIC SCIENTIFIC No. 4WH O O 90700 (SEE NOTE 2) ENCLOSURE AT OUTDOOR SITES. PORT MARKED::: 2. WIRE TO PROVIDE CONTINUITY WHEN CIRCUIT IS NORMAL."PROTECTED" DIN RAIL ATLANTIC 3. INSTALL BRIDGING CLIPS (SIEMON-SA- 1 -25 OR 2 o NA MODEL DESCRIPTION PEAK AMPS SCIENTIFIC 21607 EQUIVALENT) AS REQUIRED. 3 0 RJ48 (TYP) 4. TURN BACK AND STORE UNUSED CONDUCTORS.PTX080-3Y101 NSS 80,000 4 o JNA SURGE SUPPRESSOR THREE PHASE PLASTIC WHT GRN o 5 o D SURGE SUPPRESSOR NOTCH NOTES: "ELECTRICAL CONTRACTOR SHALL ALLOW FOR ONE GRN WHT o 6 0 ) NA 1 scALE: N.T.S. ADDITIONAL TRIP TO RE-TERMINATE 66 PUNCHDOWN BLOCK WHT BRN WIRING ONCE REVISED DETAIL# 1022 IS ISSUED BY BRN WHT o 8 o NA BECHTEL." PANEL "PI " S LT sT WHT o 110 0 , NA 1 NSS 3P30 GFI RECEPTACLE 1P15 2 LABEL } RED BLU o 11 0 3 ♦ SMOKE DETECTOR 1P15 4 1 WHT/BLU m BLU RED o 12 0 NA _ BLU/WHT 5 ♦ EXHAUST FAN 1P15 6 20 WHT/ORG vw0 RED ORG o 13 0 7 NOKIA #1 2P40 CORD REEL P15 8 2 ORG/WHT - ¢ ORG RED o 14 o J INTRUSION PORT MARKED 21 RED GRN o 15 0 9 v TELCO RECEPTACLE 1P15 10 WHT/GRN z ED "UNPROTECTED" 3 0 ¢ GRN RED — 16 — HIGH TEMP cn 11 NOKIA #2 2P40 INTERIOR ucHTs/Eb:T 1P1s 12 RJ48 TYP 6 AWG GRN/WHT 0 L) ( ) # 22 ED Of RED BRN o 17 0 Of 13 ♦ INTERIOR RECEPTACLES 1P15 14 BONDED TO MGB OR O WHT/BRN o X o g 4 BRN RED o 18 0 LOW TEMP ¢ NOTES: GROUNDED ENCLOSURE BRN/WHT ¢ 15 NOKIA 3 2P40 MOTION SENSOR 1P15 16 N w o # TO TELCO 23 p m w RED SLT o 19 Z 17 ♦ SPACE 18 1 . MOUNT DIN RAIL TO NIU 5 WHT/SLT m w = SLT RED 20 — SMOKE TELCO BOARD SLT/WHT - V) a 19 SPACE SPACE 20 2. DIN RAIL HOLDS 1 -4 N ° 00 24 m ¢ Lo BLK BLU o 21 o w 21 SPACE SPACE 22 UNITS o ° 6 RED/BLU 0 Of BLU BLK o 22 o J NSS FAIL wo 3. NSS MAY BE ORIENTED TO o BLU/RED 0 o 23 SPACE SPACE 24 SUIT SITE REQUIREMENTS. 0 25 w BLK ORG o 23 0 - w o o RED/ORG bi ¢ 0 RECT 24V G 25 SPACE SPACE 26 > v ° 7 1- Y - ORG BLK o 24 o MAINS [ w ° 0 26 ORG/RED oz d BLK GRN o 25 0 27 SPACE SPACE 28 Qz 0 0 ¢ 1 29 SPACE SPACE 30 01 T1 ESURGE SUPPRESSOR cz 0 RED/GRN � LJ o J RECT 24V 0 8 w w GRN BILK o 26 o J CHARGER ° GRN/RED 0 D- 0 ° 27 LL BLK BRN o 27 0 NOTE: o X o 0 9 RED/BRN 0cn BRN BLK o 28 r— Jl FUSE DIST 1 . CONTRACTOR SHALL PROVIDE BRANCH CIRCUITS TO ALL EQUIPMENT SHOWN CDS DATACOM INC. ATLANTA CABLE SALES INC (ACS) 0 BRN/RED o ON PANEL SCHEDULE AND FLOOR PLANS FOR A COMPLETE INSTALLATION. VENDOR Z I- 0 28 z BLK SLT w w o PANEL o 29 214-340-9199 800-241 -9881 z In 0 RED/SLT I-- No 1 AIR COND 0 ¢ 0 10 SILT BLK o 30 J PANEL SPECIFICATIONS OUTDOOR DOUBLED ENDED P# C00411484-XXX P# 010717-1 -XXX 0 0 SLT/RED 0 _o YEL BLU o 31 0 FAIL 0 120/208V, 3 PHASE, 4 WIRE INDOOR DOUBLED ENDED P# C00411467-XXX P# 010716-1 -XXX o 0 29 0 11 BLK/BLU I wJ BLU YEL o 32 0 PSAX MAINS: 200A PANEL CIRCUIT BREAKER OUTDOOR SINGLE ENDED P# C00411483-XXX P# 010717-XXX z p ° o BLU BLK ¢ JJ LL I— 30 / 1— � YEL ORG o 33 0 INDOOR SINGLE ENDED P# C00411450-XXX P# 010716-XXX ° ¢ w 1 TECH ON ENCLOSURE: NEMA 3R, SURFACE, 20" WIDE CABINET MODEL# NQOD430L225CU r- v o ° 12 BLK/ORG Y o ORG YEL o 34 o J SITE POLES: 30 XXX = LENGTH IN FEET o ORG/BLK 0 Li z 31 o W YEL GRN o 35 0 PANEL SHALL BE 42K AIC OR BETTER AND HAVE BOLI ON BREAKERS AND J Z 0 0 BLK GRN On o o BATTERY WELDED GROUND BAR KIT. COVER SHALL BE LOCKABLE WITH HINGED DOOR 23478 B WHT 00 0 13 / GRN YEL 36 ) ACTIVE N DOOR. WHT BLU R m olr i ° 32 GRN/BLK TX °STRAIGHT 0 0 37 0 2 THROUGH ° BLK/BRN PANEL SCHEDULE 3 NC CABLE 14 BRN/BLK a o 0 3g o 0 ORG WHT T CONFIGURATION" 33 w 2 SCALE: N.T S. 5 WHT ORG R RX 15 BLK/SLT a- o 0 40 0 0 ELECTRICAL SYMBOLS ABBREVIATIONS 6 NC O 34 SLT/BLK 41 0 0 o 0 7 N 16 YEL/BLU c0 0 0 42 0 o B ® GROUND ROD WITH ACCESS AWG AMERICAN WIRE GAUGE 8 NC 35 BLU/YEL 10 0 0 43 0 0 RJ48C o 0 8 CHEMICAL GROUND ROD BCW BARE COPPER WIRE g PIN CONNECTOR PIN ASSIGNMENT 17 YEL/ORG 44 0 0 DWG DRAWING CONNECTOR 18" GROUND PIGTAIL ORG/YEL o 0 45 0 0 ® GROUND ROD TS CABINET ONLY BY BTS VENDOR) CDS DATACOM P/N 36 YEL/GRN o 0 46 0 0 0-1 DISCONNECT SWITCH EMT ELECTRICAL METALLIC TUBING (GND @ BC03610075-OOXX 18 0 GEN GENERATOR NOTES: (SEE NOTES 1 ,2,3) 37 GRN/YEL o 47 0 0 METER IGR INTERIOR GROUND RING (HALO) 1 . CABLE IS A NOKIA SPECIFIC DESIGN. WIRING IS UNIQUE AND SHALL BE USED FOR 19 YEL/BRN o 0 48 0 0 IMC INTERI IEDIATE METALLIC CONDUIT NOKIA ULTRASITE INSTALLATIONS ONLY. DRAIN o 0 49 0 0 CIRCUIT BREAKERMGB MASTER GROUND BAR o 0 50 0 0 2. SELECTED CABLE MUST BE FROM A VENDOR LISTED IN THE ABOVE TABLE ■ CADWELD TYPE CONNECTION PCS PERSONAL COMMUNICATION (NO SUBSTITUTIONS ARE PERMITTED) NOTES 0 O 0 SYSTEM 3. OBTAIN CABLE AND CONNECTOR ASSEMBLY FROM: COMPRESSION TYPE CONNECTION PTS POWER TRANSFER SWITCH 3. DOUBLE ENDED CABLES ARE STANDARD. SINGLE ENDED OPTIONAL TO MEET UNIQUE CDS DATACOMM NOTE 3 SITE REQUIREMENTS. GROUNDING WIRE PVC RIGID (SCH. 40) POLYVINYL SHAWN LONG CHLORIDE CONDUIT 4. CABLE IS A STRAIGHT-THROUGH WITH IDENTICAL CONNECTOR PIN-OUT ON BOTH 972-424-7234 DIRECT XefREPRESENTS DETAIL NUMBER RRGS WY RACEWAY GALVANIZED STEEL ENDS. 972-424-7620 FAX �-REFERENCE SHEET NUMBER 2. CABLE AND 37-PIN CONNECTOR COME PREWIRED FROM 5. CABLE END WITH 18" GROUND PIGTAIL SHALL BE INSTALLED AT NOKIA BTS. CDS DATACOM. TYP TYPICAL 3. 'OOXX' = CABLE LENGTH IN FEET. ELECTRICAL SYMBOLS 6. ORDER LENGTH AND TYPE (OUTDOOR, INDOOR) AS APPROPRIATE FOR SITE S66M1 -50 REQUIREMENTS AND ABBREVATIONS T1 CABLE AND CONNECTOR PIN-OUTI� ALARM CABLE 02 66 BLOCK ALARM ASSIGNMENTS A O SCALE: N.T S. O1 SCALE: N.T.S. OZ SCALE: N.T.S. _ Q FC PROJECT NO FISHERS ISLAND �\yt�a o q�yh -4926 AT&T WIRELESS SERVICES WILLIAM F. COLLINS, AI'A 903 006 201 A AT&T -�, 06/05/03 ISSUED FOR CONSTRUCTION W AF n -- "s ELECTRICAL DETAILS AND NOTES ARCH I T E C T S, L I, P ORIENTAL AVENUE Q 10/30/02 ISSUED FOR REVIEW PL AF Tr n ` 10.l TECHNOLOGY DRIVE SETAUKET,NY II'!33 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. NO, DATE REVISIONS BY CHK APP'D `�PT� USR�/ ,ii JOB N0, SITE N0. DRAWING NUMBER IREV VOICE: 631-689-8450 FAX: 631-681 15 EAST MIDLAND AVENUE - PARAMus, NJ mss2 � 24445 903006201A E-2 0 SCALE: AS NOTED DESIGNED DRAWN: PL 2 DFN=STV[160,021 DWG 22 z 34 D SIZE 6 5 4 3 PSD- NEW AT&T 200 AMP ELECTRIC SUB-METER AT GRADE NOTE: NEW ELECTRICAL CONDUIT ROUTED AT&T 2 0 AMP POWER PANEL E 1 #2 AWG STRANDED, INSULATED COPPER WIRE MAY BE USED IN LIEU OF SOLID BCW FOR FROM NEW AT&T SUB-METER TO NEW BONDING DEVICES FROM INSIDE SHELTER TO t AT&T EQUIPMENT NEW AT&T 200 AMP "APPLETON" EMERGENCY THE EXTERIOR GROUND ROD . E-1 EXISTING ELECTRIC UTILITY METER GENERATOR RECEPTACLE AT GRADE AT GRADE EXISTING ELECTRICAL PANEL AND PLYWOOD BACKBOARD E-1 GROUNDING NOTES: NEW AT&T 200 AMP CAUTION!: AT ALL SITES THE CONTRACTOR MUST VERIFY THAT THE SYSTEM IS EFFECTIVELY GROUNDED AND MEETS THE NEC ARTICLE 250 DISCONNECT EXISTING SMOKE DETECTOR REQUIREMENTS AND ACCEPTABLE TO THE LOCAL INSPECTOR/AUTHORITY. NEC ARTICLE 250-84 SPECIFIES GROUNDING RESISTANCE OF 25 OHMS OR LESS FOR THE GROUNDING SYSTEM. THE PROJECT REQUIREMENT IS FIVE (5) OHMS. NEW TELCO COAXIAL CABLE ROUTED FROM NEW LAND LINK PARABOLIC ANTENNA IN I FuiuRE� — NOTE: NEW AT&T EQUIPMENT iwcoMBal STEEPLE ABOVE TO NEW TELCO BOARD 1 . METALLIC OBJECTS LOCATED WITHIN 6'-0" OF GROUNDING HALO SHALL BE BONDED TO GROUNDING HALO ROOM �----� � I iNOKIA \ T NOKIA Ua2. PROVIDE STRAIN RELIEF AND PROTECTION FROM SHARP MATERIAL FOR INDIVIDUAL CABLES. PROVIDE #6 GROUND CONDUCTORS WITH TWO-HOLE IBI�Ne% CONNECTORS TO CABLE RACK SECTIONS TOGETHER NEW EXHAUST FAN NEW 4'x4'x 5/8" FIRE RESISTANT PLYWOOD F2. GROUND ES: �K BACKBOARD NUMBER OF GROUNDING RODS REQUIRED, REFER TO AT&T WIRELESS SERVICES, INC. TECHNICAL SPECIFICATIONS FOR FACILITY GROUNDING. ON6� WIRES SHALL BE ROUTED INTO THE EQUIPMENT ROOM FOR CONNECTION TO THE FOLLOWING: BOND GROUND WIRE TO INTERIOR GROUND RING HALO AT A MINIMUM OF FOUR PLACES AND LOCATE CONNECTIONS ON OPPOSITE SIDES OF THRIFT EQUIPMENT ROOM. STORE - BOND GROUND WIRE TO MASTER GROUND BAR FOR INTERIOR EQUIPMENT SPECIFICATION FOR FACILITY GROUNDING, THE NEC AND LOCAL CODE U✓ d REQUIREMENTS. , EXISTING STAIR FROM - BOND GROUND WIRE TO AC POWER SERVICES AND SURGE ARRESTOR IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR FACILITY BASEMENT GROUNDING C 3. #2 AWG STRANDED, INSULATED COPPER WIRE MAY BE USED IN LIEU OF SOLID BCW FOR BONDING DEVICES FROM INSIDE EQUIPMENT ROOM TO THE EXTERIOR GROUND RODS. FOR ELECTRICAL AND GROUNDING SYMBOLS AND ABBREVIATIONS SEE DETAIL 500 SHEET E-2 tN 503 NEW GROUND ROD 4 ORIENTAL AVENUE CADWELD CONNECTION, (TYP) 514 TELCO/ELEC PLAN o e NEW THROUGH WALL EXHAUST FAN TO @ BASEMENT LEVEL �I)TE: ° z' 4' s' REPLACE EXISTING WINDOW o : FUTURE `\ 1 SCALE: 1 4" = F THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH z 1-___ � 1/4"—i,_ol. p iRK-EI _ LTRA �ISITD LCABINEi� G — #2 AWG STRANDED INSULATED (INSULATION INSPECTION WELL/W COPPER TO BE UV RESISTANT) OR BARE, SOLID, B RU GROUND AND TEST LOOP TINNED COPPER WIRE, TYP. 2 PER TB 503 CABINET NC TVSS PANE c L -4 �, , G FOR SURGE SUPPRESSOR N ' S No z ALARM, CONNECT TO COMMON NC , eL AND NORMALLY CLOSED c OaA GROUND WIRE ROUTED FROM INTERIOR C, TERMINAL BLOCKS. NORMALLY _q GROUND RING HALO TO EXTERIOR GROUND ME UTILITY POWER FAIL BIN,7 NEW INTERIOR GROUND RING CLOSED IN NORMAL POWER CLOSED CONTACTS WILL BE No ROD HALO, (HALO BY SHELTER MANUF.) FOR UTILITY POWER ALARM, CONNECT TO COMMON AND NORMALLY CLOSED CONDITIONS. CONTACTS WILL 504 MASTER GROUND BAR OPEN IF TVSS PANEL FAILS. TERMINAL BLOCKS. NORMALLY CLOSED 0_ CONTACTS WILL BE CLOSED IN NORMAL TB � POWER CONDITIONS, CONTACTS WILL 5 OPEN IF UTILITY POWER FAIL. NOTE: TB LOCATED WITHIN PANEL "P1 " 6 EXISTING STAIR FROM BASEMENT UTILITY POWER FAIL MANUF: POTTER & BRUMFIELD MODEL:# K10P- 11A15- 120 ZN AND BASE 27E487 0' 4' 8' 16' ,UTILITY POWER FAIL TVSS FAIL �(q)UIPMENT GROUNDING PLAN NOTE: A �+ scAEE: N.T.s. O SCA E: NT.s. 2t 4 = t -o' IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH FC PROJECT NO FISHERS ISLAND AT&T , NT/M/R3 ISSUED FOR CONSTRUCTION JM AF ❑ " . ;; /y ,.E�` � 4826 AT&T WIRELESS SERVICES WILLIAM F. COLLINS, AIA 903 006 201 A QO 06/ovo3 ISSUED FOR CONSTRUCTION OJ AF n A R C H I T E C T S, LLP QS 5/15/03 ISSUED FOR ZONING gc,JM aF n H'� ' �''^ TELCO/ELEC/GROUNDING ORIENTAL AVENUE a 6 PLANS, NOTES AND DETAILS 10-1 TECHNOLOGY DRIVE SETAUKET,NY11733 Q tG/3G/Gz ISSUED FOR REVIEW PL AF n .I' s : 1�; v ), VOICE: 631-689-8450 FAX: 631-689-8459 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. 15 EAST MIDLAND AVENUE N DDATE REVISIONS BY CHK APP'D `•fpr 028994 ��,j; JOB N0. SITE NO. DRAWING NUMBER R EV PARAMUS, NJ 07652 '�• (7p l,i •I „� SCALE: AS NOTED DESIGNED PRAWN; PL 24445 903006201A E-3 6 4 3 DEN—SN[16D.02] DWG _Mx 34 7-SIZE PSC- z \ REMOVE EXISTING SMOKE P1 - 14 DETECTOR COPPER WIRE TEST LOOP GRADE � FUTURE 1 -8 NEW POWER PANEL "P1 " EZ PRECAST CONCRETE INSPECTION "COMA EX HAND HOLE ASSEMBLY WITH N FUTURE NEW CORD REEL CAST IRON FLANGE AND COVER NOKIA HSE F2 WITH WORD 'GROUND' CAST _z P1 - 10 INTO COVER. CADWELD P1 -6 P1 -4 GRADE NEW SMOKE DETECTOR, NEW 4' D TEL 8" THICK -"- D PLYWOOD TELCO BOARD — GRAINGER OR EQUAL F CADWELD CABLE —I —� MODEL# 3KN55/57 ElW TO ROD. _ �_ #2 AWG BCW El - � NEW MOTION SENSOR SOLID, TINNED ' 4 — — P1 - 11 , Ex CLEAN SAND GROUND P1 - 11 , 13I ' P1 -12 NEW EMERGENCY LIGHT FILL P1 - 15,17 THERMOSTAT COPPER WIRE GROUND ROD NEW EXIT SIGN, TYP. GROUND RING n COPPER CLAD STEEL 5/8"o x10'-O" LONG EXISTING STAIR FROM BAS EM N ET GROUND ROD COPPER CLAD STEEL 3/4" X BASEMENT PLAN 10'-0" LONG. LIGHTING SCHEDULE c SYM. MANUFACTURER / MODEL # TYPE FIXTURE LAMP NO. LAMPS MOUNTING HEIGHT REMARKS WATTAGE TYPE WATTS DETAIL @ GROUND TEST WELL DETAIL @ GROUND ROD F2 LEGION CAT. # 4304-232-ACP-ESB/EBO -BA FLUOR. 62 F032-TS 2-32 SURFACE/ STEM SURFACE/STEM MOUNTED NARROW WRAP 2 SCALE: N.T.s. 0 scALe N.T.S. EX ATLITE CAT # XLN 18SR2U-BA LED. 2 LED 1 -2 WALL/ CEILING EMERGENCY EXIT SIGN, SHADING INDICATES FACES, ARROW INDICATES DIRECTION EM ATLITE CAT # 12ACNY2-BA INCAND. 36 12V PAR36 2- 12 WALL/ CEILING 2 HEAD EMERGENCY UNIT X ST AWG TO GROUND BAR ANTENNA CABLE (D 11 tN STRANDED � INSULATED TWO HOLE LONG ENLARGED LIGHTING BARREL LUG TELCO OR POWER CABLES WEATHERPROOFING KIT AND ELECTRIC PLAN NOTE: 2' 4' METALLIC (SEE NOTE 3) 1 IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH CONDUIT SCALE: �/a =� -o BURNDY TYPE GAR-TC GROUND CABLE GROUND KIT 17a�,=1�_U�� CONNECTOR (CAT# GAR3903TC) #6 AWG STRANDED COPPER GROUND 4 � 1 METALLIC CONDUIT CABLE POWER OR WIRE (GROUND ED TO GROUND BAR), #6 AWG FROM ANTENNA (SEE NOTE 1 & 2) B CABLE GROUND KIT #6 AWG STRANDED 0 7/16„ 374 0 0 0 INSULATED GROUND CABLE. CONNECTION OF CABLE GROUND STRIP INSULATION IN 2 0 0 0 0 0 0 METALLIC AREA OF CADWELD KIT TO ANTENNA CABLE 0 0 0 0 0 0 CONDUIT 3 0o ° 0 o CADWELD OR BOND 6 08 GROUNDING # NOTES: 0 0 GROUND WIRE TO SAME 1 , DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT i o E-a BUSHING GROUND BAR TO WHICH 1 GROUND CABLE IS ATTACHED, GROUND WIRE DOWN TO GROUND BAR. �00� C 00 �OO p c - LEGEND METALLIC CONDUIT WITH 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR GROUND WIRE RECOMMENDED BY CABLE MANUFACTURER. Op 1 . COPPER GROUND BAR, 1 /4" X 4" X 20", NEWTON INSTRUMENT CO. CAT. NO, B-6142, HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK TWO HOI E LUG, TO 2. INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061 -4 SHALL NOT BE USED. BE USESWITH 3. 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT NO. 3015-8 #2 AWG BCW TO BUILDING OR GROUND 4. WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 RING/HA .O 5. 5/8- 11 X 1 " H.H.C.S. BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012- 1 Q„ GROUND WIRE TO GROUND ROD AGROUND BAR DETAIL CONDUIT BONDING DETAIL i DETAIL @ CABLE GROUNDING KIT A VV SCALE: N.T.S. V SCALE: N.T.S. <0 y" SCALE: N T.S. ■ v SCALE: N T.S -� Q c PROJECT No AT&T WIRELESS SERVICES �ae�,i FISHERS ISLAND = AT&T /� � DEp ,\, 2-4x26 903 006 201 A _ /1 QC W/�3/0] ISSUED FOR CONS RUCTION M AF T k WILLIAM F. COLLINS, AIA — ENLARGED LIGHTING/ELECTRIC 0 Ofi/DS/O] ISSUED FOR CONSTRUCTION GJ AF TT _ - ' S ARCHITECTS, LLP � Q : 4a * PLAN AND GROUNDING DETAILS ORIENTAL AVENUE ,�L 10/30/02 ISSUED FOR REVIEW PL AF 7F 1a1 TECHNOLOGY DRIVE SETAUKET,rn11733 AT&T WIRELESS SERVICES, INC. �`�0 026 FISHERS ISLAND, NY 1 1957 NO, DATE REVISIONS By CHK APP'D n JOB N0. SITE NO, DRAWING NUMBER REV VOICE: 631-689-8450 FAX: 631-689-8459 15 EAST MIDLAND AVENUE \F PARAMUS, NJ 07652 OF NF�T�. SCALE: AS NOTED DESIGNED DRAWN: PL - 24445 903006201A E-4 1 DFN=SN[160,021 .DWG 6 5 4 3 2 22 x 34 D SIZE 7' t PSC= 900 TX/RX 1900 TX/RX NOTES: 1 . ALL MATERIAL ON THE TABLE BELOW SHALL CELL SITE INSTALLATION NOTES: BE PROCURED BY BECHTEL. THE FOLLOWING INSTALLATION NOTES HAVE BEEN COMPILED FROM THE I . ALL ANTENNA COAXIAL CABLES AND JUMPERS SHALL BE INSTALLED 2. THE CONTRACTOR SHALL NOT EXCEED THE EXISTING PROJECT DOCUMENTS (I.E. PROJECT SPECIFICATIONS, EQUIPMENT WITHOUT LOOPS AND/OR PIGTAILS. 1 CABLE LENGTHS SHOWN ON THE DRAWING VENDOR DOCUMENTS, ETC.) FOR USE. THESE NOTES SHALL BE UTILIZED WITHOUT RF ENGINEERING APPROVAL. FOR THE CONSTRUCTION OF THE CELL SITES TO ENSURE COMPLIANCE QUADPOLE SECTOR 3. CABLE LENGTHS LISTED ARE APPROXIMATIONS WITH THE PROJECT DESIGN AND SPECIFICATION REQUIREMENTS. 2. ANTENNA COAXIAL CABLE GROUND KITS SHALL NOT BE INSTALLED ON THE JUMPER BETWEEN THE ANTENNA AND MAIN LINE CABLE. ANTENNA, TYP. BASED ON THESE PLANS AND ARE NOT A. GROUNDING: LAND LINK PARABOLIC INTENDED TO BE USED FOR ORDERING CABLE. 7/16" D N TYPE FEMALE DISH ANTENNA ALL CABLE LENGTHS MUST BE V.I.F. ALL METAL CONDUIT FOR GROUNDING DOWN CONDUCTORS SHALL BE 3. ANTENNA COAXIAL CABLE GROUND KITS SHALL BE INSTALLED AS CLOSE CONNECTOR (ANTENNA) BONDED TO THE GROUND SYSTEM AT BOTH ENDS. TO THE CONNECTOR AS POSSIBLE AT EACH ANTENNA. IF THIS IS NOT D 4. COLOR CODE ALL MAIN 2. GROUNDING CONDUCTORS SHALL BE CONNECTED TO THE MAIN WATER FEASIBLE THE GROUND KIT SHALL BE INSTALLED IMMEDIATELY AFTER THE 5 TOP JUMPER CABLE CABLES AT TWO LOCATIONS: PIPE USING A BURNDY TYPE GAR-TC CLAMP. 2A (IF REQUIRED) NEAR ANTENNA, BEND ON THE FIRST STRAIGHT RUN OF CABLE. THE GROUND KIT SHALL NEAR EQUIPMENT 3. KOPR-SHIELD ANTI-OXIDATION COMPOUND SHALL BE USED ON ALL BE INSTALLED ON STRAIGHT SECTION OF CABLE ONLY AND NOT ON GROUNDING CONNECTIONS. BENDS. 2 -////-MAIN COAXIAL CABLE 5. ANTENNAS SHALL BE PROCURED AND 4- ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE 4. ANTENNA COAXIAL CABLE SHALL BE INSTALLED TO COMPLY WITH THE INSTALLED WITH DOWNTILT BRACKETS AND CADWELD PROCESS. 2AHEAVY DUTY CLAMPS SUPPLIED BY ANTENNAMANUFACTURER'S MINIMUM BEND RADIUS SPECIFIED IN THE FOLLOWING MAIN COAXIAL CABLE MANUFACTURER UNLESS OTHERWISE NOTED. 5- ALL CADWELDS SHALL BE INSTALLED USING THE PROPER CONNECTION / TABLE. THE CONTRACTOR SHALL INSTALL RACEWAY FOR COAXIAL CABLE 4 GROUNDING KIT < 13A MOLD AND MATERIALS FOR THE PARTICULAR CONNECTION OR USING THE PROPER FITTINGS NECESSARY TO ENSURE THAT THE MINIMUM E-a 6. TOP AND BOTTOM JUMPERS SHALL BE N AND/ SUPPLIED AND INSTALLED BY THE EQUIPMENT APPLICATION. BEND RADIUS REQUIREMENTS ARE MET. PROVIDE A DRIP LOOP AT 3 GRouIvelNG KIT E134 MANUFACTURER. TEE CONNECTION SWEEP CONNECTION POST CONNECTION ANTENNA. GROUND BAR (NEAR sos ANTENNAS), SEE DETAIL @ 7. CONTRACTOR SHALL VERIFY ANTENNA TYPE ANTENNA POST GROUND BAR sos AND AZIMUTH WITH CONSTRUCTION MANAGER COAXIAL CABLE MINIMUM BEND RADIUS (NEAR ANTENNAS) E a PRIOR TO STARTING CONSTRUCTION. CADWELD CADWELD MINIMUM BEND MINIMUM BEND 8. CONTRACTOR SHALL PROVIDE AN CABLE SIZE RADIUS IN /' CADWELD #2 AWG MANUF. CABLE TYPE RADIUS IN GROUND BAR 22 INDEPENDENT TESTING AGENCY TO PERFORM #2 #2 BCW (DIAMETER) TRAY 4" OR 6" CONDUIT (AT EQUID.) E_4 COAXIAL SWEEP TEST AND REPORT, AND AWG AWG SEE DETAIL PROVIDE THE NECESSARY QUALIFIED BCW BCW ANDREWS LDF5-50A 7/8" 10" CONTACT COAX MANUF. #2 AWG INSULATED PERSONNEL AND EQUIPMENT NEEDED TO #2 AWG INSULATED GROUND WIRE ASSIST IN ANY REPAIRS AND WEATHER 6. ALL BOLTED GROUNDING CONNECTIONS SHALL BE INSTALLED WITH A LOCK ANDREWS LDF6-50 1 1 /4" 15" CONTACT COAX MANUF. GROUND WIRE PROOFING. CONTRACTOR IS TO PROVIDE WASHER UNDER THE NUT. HARDWARE FOR BOLTED CONNECTIONS SHALL ANDREWS LDF7-50A 1 58" 20" CONTACT COAX MANUF. _ _ BECHTEL WITH A MINIMUM OF 48 HOURS BE MINIMUM OF 3/8" DIAMETER AND SHALL BE STAINLESS STEEL. / COPPER PLATE NOTICE PRIOR TO TIME OF SWEEP TEST AND C EQUIPMEIJT FURNISH RESULTS WITHIN 48 HOURS OF GROUND BAR COMPLETION. ALL SWEEP TESTING TO BE 7. OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISHING A "CHOKE" POINT. BASEMENT (AT EQUIP.) E°y DONE IN ACCORDANCE WITH SPECIFICATION GROUNDING WIRE SHALL NOT BE INSTALLED OR ROUTED THROUGH HOLES EQUIPMENT SECTION 24. IN ANY METAL 4 4 9. ALL INDICATIONS OF NORTH ARE FOR 5. ALL ANTENNA COAXIAL CABLES SHALL BE MARKED IN ACCORDANCE WITH REFERENCE ONLY. CONTRACTOR VERIFY SE 6 IN FIELD TRUE NORTH PRIOR TO SECTOR THE REQUIREMENTS IN BECHTEL ENGINEERING STANDARDS DOCUMENT 5 BOTTOM JUMPER CABLE 5 ANTENNA INSTALLATION. #24445-801 -3DS-GET-0002-001 . 6. THE CONTRACTOR SHALL ORIENT THE COAXIAL CABLES ON THE ICE BRIDGE TO MATCH WITH THE ORIENTATION OF THE COAX ENTRY HATCH LAND LINK ALPHA SECTOR BETA SECTOR GAMMA SECTOR TOTAL I PLATE ON THE SHELTER. ITEM ITEM DESCRIPTION AZIMUTH 36. 15 AZIMUTH 70' AZIMUTH 240' AZIMUTH 310' QUANTITY N0. TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX (SEE NOTE 1 #2 AWG BCW 7. ONLY ANDREWS GROUNDING KITS SHALL BE USED ON ANDREWS CABLE. ANTENNA DEPICTS CHOKE POINT THE FOLLOWING IS A LIST OF PART NUMBERS FOR GROUNDING KITS. 1 ANDREW DECIBEL DECIBEL DECIBEL DECIBEL DECIBEL (NOT ACCEPTABLE) (SEE NOTE 5) P3F-52-N7A 731DG65V1EXM 731DG65V1EXM 731DG65V1EXM 731DG65V1EXM 731DG65V1EXM 5+ 1 AS-BUILT SERIAL # 8. FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUNDING MECHANICAL CONDUCTOR SHALL NOT BE USED. CLIPS OF THE FOLLOWING MATERIALS NOMINAL ANDREWS DOWNTILT UPTILT 0.06' 0' 0' 0' 0' 0' AND TYPES MAY BE USED TO FASTEN AND SUPPORT GROUNDING CABLE SIZE ANDREWS STANDARD ANTENNA JUMPER CONDUCTORS. (DIAMETER) CABLE TYPE GROUND KIT 2 (ANDREW) N/A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-5DA (LENGTH) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /�2" (6 FEET) 1 /2" (6 FEET) 60 FT PLASTIC CLIPS 7/8" LDF5-50A SGL5- 10B4 ATTACHED MALE DIN INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED 1 1 /4" LDF6-50 SGL6- 10B4 2A CONNECTOR (1 ) LSPNM-RPC W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2 1 5/8" LDF7-50A SGL7- 10B4 B (ANDREW) AIN COAX ° METAL CLIPS WHICH DO NOT COMPLETELY SURROUND THE 3 (LENGTH) (1 ) 5/8"0 (65- 1 (2) %" ((65') (2) %"0 (72') (2) �/8"0 (72') (2' /a"d (85') (2) 7/8"0 (85') 763 FT 7/8"0) GROUNDING CONDUCTOR 8. SNAP-IN HANGERS USED FOR 7 8 ANDREWS CABLE SHALL BE ANDREWS (ANDREW) LDF4.5-50 LDF5-50A LDF5-50A LDF5-50A LDF5-50A LDF5-50A 65 FT (5/8"0 SNAP-IN HANGERS. SNAP-IN HANGERS USED FOR 1 1 /4" AND 1 5/8" UNATTACHED MA 1 ) DIN F MALEANDREWS CABLE MAY BE ANDREWS SNAP-IN HANGERS OR EQUIVALENT 4 DIN CONNECTOR Q) EQ. L5PDF-RPC L5PDF-RPC L5PDF-RPC L5PDF-RPC L5PDF-RPC 20 HANGERS FROM ANOTHER VENDOR. (ANDREW) -4.5RDF-RCI UNATTACHED MALE (2) N MALE 5 DIN CONNECTOR ANT L4PDM-RPC L4PDM-RPC L4PDM-RPC L.4PDM-RPC L4PDM-RPC 20 9. HOISTING GRIPS USED FOR 7/8", 1 1 /4" AND 1 5/8" ANDREWS CABLE (ANDREW) L4.5PNM-RC 9. STANDARD GROUND BARS SHALL BE FURNISHED AND INSTALLED. THEY MAY BE ANDREWS OR EQUIVALENT HOISTING GRIPS FROM ANOTHER ANTENNA JUMPER SHALL NOT BE FABRICATED OR MODIFIED IN THE FIELD. VENDOR. FOR 1 5/8" COAXIAL CABLE, A STAINLESS STEEL HOSE CLAMP 6 (ANDREW) LDF4-50A C(2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A 60 FT MUST BE INSTALLED WITH THE HOISTING GRIP. (LENGTH) 1 /2" (6 FEET) 2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 10. ALL GROUND WIRES SHALL BE INSTALLED WITHOUT LOOPS (PIGTAILS) AND SHARP BEND RADIUS. 7 ID TAG ALPHA 2 ALPHA 1 BETA 1 BETA 2 GAMMA 1 GAMMA 2 C. MANUFACTURED MATERIAL: 8 COLOR CODE 3 GREEN G EEN TW ONE BLUE TWO BLUE ONE WHITE TWO WHITE B. ANTENNA COAXIAL CABLES �WAVEGUIDE) TWO GREEN 1 . WHEN SPECIFIC MANUFACTURER'S ITEMS ARE SPECIFIED, THEY MAY BE 1 NOTE: THE RF TRANSMISSION LINE INSTALLED BETWEEN THE RADIO REPLACED BY SIMILAR, EQUIVALENT ITEMS WITH PRIOR ENGINEERING CABINET, FURNISHED BY RBS EQUIPMENT SUPPLIER, AND THE ANTENNA APPROVAL. CONSISTS OF A COAXIAL CABLE, SOMETIMES REFERRED TO AS A /ANTENNA SCHEDULE WAVEGUIDE. A FC PROJECT NO Q 07/09/03 ISSUED FOR CONSTRUCTION JN AT TT ;\ -4926 AT&T WIRELESS SERVICES FISHERS ISLAND AT&T DER411 �--� Qp 06/05/09 ISSUED FOR CONSTRUCTION WILLIAM F. COLLINS, AIA 903 006 201 A - f ' ANTENNA CABLING SCHEMATIC A R C H I T E C T S, LLP s/1s/m IssueD FOR zonlNc Ac,JN AF Tr ORIENTAL AVENUE J r AND DETAILS QA 10/30/01 ISSUED FOR REVIEW PL AF TI � _ 10.1 TEC14NOLOGY DRIVE SE'CAUKET,NY 11733 AT&T WIRELESS SERVICES, INC. VOICE: 631-689-8450 FAX: 631-689-8459 FISHERS ISLAND, NY 11957 15 EAST MIDLAND AVENUE NO. DATE REVISIONS BY CHH APP'D \e ly JOB NO. SITE N0, DRAWING NUMBER REV PARAMUS, NJ 07652 OF 24445 903006201 A E-5 1 SCALE: AS NOTED DESIGNED DRAWN: PL 6 5 4 3 2 DFN=STV[160,02] DWG 22 x N SIZE PSC=