HomeMy WebLinkAbout29432-Z FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-30234 Date: 06/08/08
THIS CERTIFIES that the building ALTERATION
Location of Property: OCEANIC AVE FISHERS ISLAND
(HOUSE NO. ) (STREET) (HAMLET)
County Tax Map No. 473889 Section 9 Block 7 Lot 11.1
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated MAY 27, 2003 pursuant to which
Building Permit No_ 29432-Z dated MAY 28, 2003
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is WIRELESS COMMUNICATIONS ANTENNA INSTALLED IN AN EXISTING CHURCH
BUILDING AS APPLIED FOR PER SPECIAL EXCEPTION ZBA 45311 DATED 5/15/03.
The certificate is issued to OUR LADY OF GRACE RC CHURCH
(OWNER) ,
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO_ 1197379 03/09/04
PLUMBERS CERTIFICATION DATED N/A
uthor zed Signature
Rev. 1/81
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 29432 Z Date MAY 28 , 2003
Permission is hereby granted to :
LADY OF GRACE RC OUR
PO BOX 425
FISHERS ISLAND,NY 06390
for
CONSTRUCTION OF A WIRELESS COMMUNICATIONS ANTENNA IN AN EXISTING
CHURCH BUILDING AS APPLIED FOR
at premises located at OCEANIC AVE FISHERS ISLAND
County Tax Map No. 473889 Section 009 Block 0007 Lot No. 011 . 001
pursuant to application dated MAY 27, 2003 and approved by the
Building Inspector to expire on NOVEMBER 28 , 2004 .
Fee $ 200 . 00
Author ze Signature
ORIGINAL
Rev. 5/8/02
Form No.6 IF
TOWN OF SOUTHOLD
BUILDING DEPARTMENT I�_
TOWN HALL ao1�
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy
is denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00,
Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$25.00
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy- Residential $15.00, Commercial $15.00
Date. NO I oil I2 001
New Construction: Old or Pre-existing Building: ✓ (check one)
Location of Property: OCEANIC AVE F-ISHEKS ISLAMD
House No. Street Hamlet
Owner or Owners of Property: LAW OF GRACE CSC. OUR
Suffolk County Tax Map No 1000, Section Oct Block Lot i I .
Subdivision Filed Map. Lot:
Permit No. Aq 1}'�jZ Date of Permit 05 3 Applicant: LAN OF (��E R `r' OUR
Health Dept. Approval: Underwriters Approval: 3f q&q (a@EQcj W)
Planning Board Approval: /
Request for: Temporary Certificate Final Certificate: V (check one)
Fee Submitted:$ So .C)r1
t
�I _I _�,Z Applicant Signature
o Im
5 5 BY THIS CERTIFICATE OF COMPLIANCE HE
NEW YORK BOARD OF FIRE UNDERWRITERS 5
5 BUREAU OF ELECTRICITY 5
5 40 FULTON STREET — NEW YORK, NY 10038 55
5 CERTIFIES THAT S
5 Upon the application of upon premises owned by 5
BBID REMODELING AND RESTOR. OUR
ALPINEDYOF GRACE
O5
FISHERS ISLAND, NEW YORK 06390, FISHERS ISLAND, NY 06390 c
5 Located at 33 ALP9ENUE FISHERS ISLAND, NY 06390
Application Number1973 Certificate Number: 1197379 5
,lc Section: Block: Lot: Building Permit: BDC: nsl 1 C5�
Described as a Commercial occupancy,wherein the premises electrical system consisting of �c
5 electrical devices and wiring, described below, located in/on the premises at: 5
5 Basement, 5
5 was inspected in accordance with the National Electrical Code and the detail of the installation,as set forth below,was 5
found to be in compliance therewith on the 9th Day of March, 2004.
5 Name OTY Rate Rating Circuit Type
5 Dj Alarm and Emergency Equipment rj
Sensor 1 0 Smoke 5
5 Combo Exit and Emergency Light 1 0 5
5 Transfer Switch 1 0 200 amp 5
5 Appliances and Accessories 5
Exhaust Fan 1 0 F.H.P. �+
5 Wiring and Devices 5
5, Receptacle 3 0 General Purpose
ISwitch 3 0 General Purpose 5
5 Fixture 2 0 Fluorescentsli
5
ISM 5
5 5
IN
ISM
S
5seal
5
1 of 1
This certificate may not be altered in anyway and is validated only by the presence of a raised seal at the location indicated. 5
5 5
0 L3rL3 3PCj@ rJ�r rL cncn cn rJrJr nrJr�r r1rJrJr ncnrJrJrltrrRPLrL3r@rL3 @r@rL3L3rL3r.rdnr�cnrr�cnc n rr� rJ�rJr�r�rJ� PLIo
05/23/2003 15:41 6317659064 ZONINGAPPEALSBOARD PAGE 01
APPEALS BOARD MEMBERSgUFFO��
Southold'''own Hall
53095 Main Road
Lydia A. Tortora, Chairwoman �T P.O.Box 1179
Gerard P. Goehringer ;
George Horning � � � Southold,New lbrk 11971-0959
ZBA Fax(6+1)765-9064
Ruth D. Oliva( #t �a� 'Telephone(631)765-1809
Vincent Orlando http://southoldtown.northfork.net
BOARD OF APPEALS
TOWN OF SOUTHOLD
May 23, 2003
Fax and Regular Mail
Lawrence C. Re, Esq.
Munley Meade Nielsen & Re
36 North New York Avenue
Huntington, NY 11743
Re: Appl. No. 5311 — Special Exception (AT&T, Fishers Island)
Dear Mr. Re:
Enclosed please find a copy of the Board's determination regarding the
above application.
The next step in the Town's zoning review-application process would he to
continue with the Planning and Building Departments for approvals. You may
want to furnish an extra copy of this determination to the other agencies if maps or
other documentation are being filed.
Thank you.
Very truly yours,
-
L(nda Kowalski
Enclosure
Copy of Decision to:
Building Department
Planning Board
05/23/2003 15: 41 6317659064 ZONINGAPPEALSBOARD PAGE 02
APPEALS BOARD MEMBERS � gt,FFO(,��
Southold Town Hall
Lydia A.Tortora,Chairwoman 53095 Main Road
Gerard P. Goehringer so P.O. Box 1179
George Horning Oy Southold,New York 11971-0959
Ruth D. OlivaO� ZBA Fax(f31)765-9064
Vincent Orlando Telephone (631)765-1809
http://southoldtown.northfork.net
BOARD OF APPEALS
TOWN OF SOUTHOLD RECEIVED 1�cf
FINDINGS, DELIBERATIONS AND DETERMINATION
MEETING OF MAY 15, 2003 MAY 2 2 2CC3
Appl. No. 5311 —AT&T WIRELESS (Our Lady of Grace Church)
Property Location: Oriental Avenue, Fishers Island; Parcel 1000-9-7-11.1.
Zone District: R-80 Residential. iovlhaldT.0Wn Clerk
FINDINGS OF FACT
The Zoning Board of Appeals held a public hearing on this application on May 1 F, 2003, at
which time written and oral evidence were presented. Based upon all testimony,
documentation, personal inspection of the property, and other evidence, the Zoning Board finds
the following facts to be true and relevant:
PROPERTY FACTS/DESCRIPTION: The applicant's property contains 2.4+- acres, located
along the north/east side of Oriental Avenue, distant 225.72 ft. east of Alpine Avenue. The
property is improved with a Church, a two-story residence (rectory), and detached garage.
APPLICANT'S REQUEST/BASIS OF APPLICATION: The Applicant, AT&T is a prospective
tenant regarding land owned and occupied by Our Lady of Grace Church, proposing a personal
communication service (PCS) facility and six panel antennas internally mounted within the
steeple of the church building. There will also be associated equipment cabinetry within the
basement of the church. Existing louvers in the steeple will be replaced with radio frequency
(RF) transparent (stealth) material that will replicate the existing louvers. Antennas will be
affixed to the interior of the upper steeple behind the stealth material. The Applicant is
requesting a Special Exception under Article 100-162A.1 for the proposed installation of a
Wireless Telecommunications Facility use, as shown on maps prepared by Neil Alexander
MacDonald, R.A. issued 5/15/03. All parking and screening will be determined by the Southold
Town Planning Board as provided under the Zoning Code site plan regulations.
WIRELESS COMMUNICATION FACILITY DEFINED: Chapter 100 (Zoning) of the Town of
Southold defines the applicant's proposed use under Section 100-162 as follows:
Any unstaffed facility for the transmission and/or reception of wireless
telecommunications services or other radio transmission and/or receiving service or use
usually consisting of a wireless communication facility array, connection cables, an
equipment facility and a support structure to obtain the necessary elevation. The support
structure is either a building, telecommunication or radio antenna or tower or other
approved structure. [Added 11-12-1997 by L.L. No. 26-1997; amended 2-2-1999 by L_L.
No. 3-1999).
05/23/2003 15: 41 6317659064 ZONINGAPPEALSBOARD PAGE 03
Page 2-May 15,2003
Appl.No.5311 -AT&T Wireless
9-7-11.1 at Fishers Island
CODE ARTICLE XVI: Section 100-160 of the Zoning Code allows wireless communication
facilities, and particularly telecommunication towers, to be reviewed and approved in keeping
with the town's existing zoning and historic development pattens, including the size and
spacing of structures and open spaces. Furthermore, the standards herein r"flect two
preferences: that wireless communication facilities are preferred in industrial areas and that
wireless communication facilities be located on existing buildings and towers rather than on
newly constructed towers- Any wireless communication facility must take into account the
aesthetic aspects of the town, including open vistas, scenic byways and historic districts. In
addition, the following provisions apply:
§ 100-161 . Scope. [Amended 12-8-1998 by L.L. No. 25-1998] The regulations of this
article shall govern and control the erection, enlargement, expansion, alteration,
operation, maintenance, relocation and removal of all wireless communication facilities.
The regulations of this article relate to the location and design of these facilities,and shall
be in addition to the provisions of the Southold Building and Zoning Codes and any other
federal, state or local laws or Federal Communication Commission (FCC) regulations
pertaining to such facilities. Nothing herein shall be construed to, apply to, prohibit,
regulate or otherwise affect the erection, maintenance or utilization of antennas or
support structures by those licensed by the Federal Communications Commission
pursuant to Chapter 47 of the Code of Federal Regulations, Part 97, to operate amateur
radio stations.
§ 100-162. Location of use. No wireless communication facility shall be used, erected or
altered in the Town of Southold when located in an R-80 Residential Zorie District,
except by (Planning Board) site plan approval, meeting the following requirements.
(1) Wireless communication facilities on buildings shall require a special exception
approval pursuant to this article. Wireless communication facilities on buildings shall be
no higher than 10 feet above the average height of buildings (excluding signs, fences
and walls) within 300 feet of the proposed facility. The building on which the wireless
communication facility is located must be located at least 100 feet from the nearest
property line and 300 feet from any landmark property or district listed by federal, state
or town agencies.
(2) Wireless communication facilities on existing telecommunications towers shall
require a special exception approval pursuant to this chapter unless otherwise allowed
by the terms of a prior special exception approval.
(3) Wireless communication facilities on telecommunication towers shall require special
exception approval pursuant to this article and shall not project higher than 10 feet
above the average height of buildings (excluding signs, fences and walls)within 300 feet
of the facility or, if there are no buildings within 300 feet, these facilities shall not project
05/23/2003 15:41 6317659064 ZONINGAPPEALSBOARD PAGE 04
Page 3—MaY 15,2003
Appl.No.5311 —AT&T Wireless
9.7.11.1 at Fishers Island
higher than 10 feet above the average tree canopy height in that radius measured from
ground level. If there are no buildings within 300 feet of the proposed facility site, all
telecommunication towers shall be surrounded by dense tree growth to screen views of
the facility in all directions. The base of the tower shall be located at least 100 feet from
the nearest property line and 300 feet from a landmark property or district listed by
federal, state or town agencies.
(4) A wireless communication facility is a permitted use, not requiring site plan approval,
if located on property owned, leased or otherwise controlled by state, federal or town
government, provided that a license or lease authorizing such facility has been approved
by that government. The height of such facility may be established by the public agency.
(5) A wireless communication facility is a permitted use, not requiring site plan approval,
if located on property owned, leased or otherwise controlled by a special district,
provided that a license or lease authorizing such facility has been approved by the
commissioners of the special district, and provided that It does not exceed the maximum
heights specified above.
Standards. In addition to the standards in Article XXVI of this Code, the Zoning Board of
Appeals finds and determines the following:
(1) The applicant is a public utility.
(2) Construction of the proposed facility or modification of the existing facility is a public
necessity, in that it is required to meet current or expected demands of the
telecommunications provider and to render adequate service to the public.
(3) The applicant has made substantial effort to locate or collocate on existing towers or,
failing that, that the applicant has made substantial effort to locate on federal, state or
town land and facilities.
(4) The facility conforms with applicable FCC regulations.
(5) There are compelling reasons, economic or otherwise, which make it more feasible
to construct the proposed facilities than alternatives.
OTHERCONSIDERATIONS: In addition to considerations under Article XXVI (Special
Exceptions) of Chapter 100, the Zoning Board of Appeals has given consideration to the
following in issuing a special exception approval for a wireless communication facility:
05/23/2003 15: 41 6317659064 ZONINGAPPEALSBOARD PAGE 05
Page 4-May 15,2003
Appl.No.5311 -AT&T Wireless
9-7-11.1 at Fishers Island
(1) The height of the proposed structure/tower is the minimum necessary to render adequate
service, inside the existing steeple of the church building. The antennas and equipment will not
be visible from the exterior as proposed.
(2) The antenna for the wireless communication facility is situated within a building and is
minimized by its proximity and little or no visibility to residential structures, residential district
boundaries and landmarks designated by town, federal or state agencies.
(3) The wireless communication facility and its antenna(s) are designed and situated to be
compatible with the nature of uses on adjacent and nearby property.
(4) The wireless communication facility has been designed to use the surrounding topography
to minimize its visual impacts.
(5) The wireless communication facility has been designed to use the surrounding tree, building
or foliage coverage to minimize its visual impacts.
(6) The wireless communication facility maximizes design characteristics to reduce o~ eliminate
visual impacts or obtrusiveness.
(7) The applicant is a public utility.
(8) Construction of the proposed facility, or modification of the existing facility, is a public
necessity in that it is required to meet current or expected demands of the telecomrrun!cations
provider and to render adequate service to the public. The applicant has established that the
facility is necessary to fill in a gap in service for its established cellular telephone customer
base, as well as allow for the overall expansion of the working range for their service in the
eastern Long Island region, and, in particular, the community of Fishers Island, in the Town of
Southold, New York.
(9) The applicant has made substantial effort to locate or collocate on existing towers or, failing
that, that the applicant has made substantial effort to locate on federal, state, or tows land and
facilities. This effort is demonstrated by the applicant's Alternate Site Analysis of two other
possible site locations in the vicinity of Fishers Island, including a pre-existing microwave facility
currently maintained by AT&T Wireless, on the western end of the island, under a long term
lease arrangement with the Fishers Island School District.
(10) The facility conforms with applicable FCC regulations.
(11) There are compelling reasons, economic or otherwise, which makes it more feasible to
construct the proposed facilities, rather than alternatives. The use of an existing church bell
steeple is cost effective to pursue, and insures that there will be no visible detrimental
05/23/2003 15:41 6317659064 ZONINGAPPEALSBOARD PAGE 06
Page 5—May 15,2003
AWL No.5311 —AT&T Wireless
9-7-11.1 at Fishers Island
environmental impact, since the appearance of the steeple will remain the same, and the
antennas will not be seen.
RESOLUTION OF THE BOARD: In considering all of the above factors and applying the
balancing test under New York Town Law 267-B, motion was offered by Member Horning,
seconded by Chairwoman Tortora, and duly carried, to
GRANT the Special Exception, as applied for and as shown on the site map prepared by
Neil Alexander MacDonald, R.A. issued 5/15/03.
This action does not authorize or condone any current or future use, setback or other feature of
the subject property that may violate the Zoning Code, other than such uses, setbacks and
other features as are expressly addressed in this action.
Vote of the Board: Ayes: Members Tortora (Chairwomen), Goehringer, Horning and
Orlando. (Absent was Member Oliva.) This Resolution was duly adopted (4-0).
Ly ' A. Tortora. Ch irwoman 5/jZ1. 103
PLANNING BOARD MEMBERS OSVffU(�C
BENNETT ORLOWSKI,UR.. P.O. Box 1179
Chairman =Q y� Town Hall, 53095 State Route 25
o Southold, New York 11971-0959
RICHARD CAGGIANO W Telephone (631) 765-1938
WILLIAM J.CREMERS O Fax(631) 765-3136
KENNETH L. ARDS
MARTIN H.SIDOR
PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
February 11,2003
Mr. Lawrence C. Re
Munley, Meade, Nielsen & Re
36 North New York Avenue
Huntington, N. Y. 11743
RE: Our Lady of Grace Church, Fishers Island
SCTM: 9-7-11.1 Zone: R-80
Proposed AT & T Wireless Antennas
Dear Mr. Re:
The Planning Board reviewed and approved your request for a Site Plan Waiver
at its Work Session on Monday, February 10,2003. Inasmuch as the proposed
antennas will be concealed within the Church building, and is similar to other
antennas which have been approved in existing churchs, the Planning Board
feels the Waiver is appropriate, since there will be no change in use or intensity
on the site.
Please contact this office if there are any further questions on this matter.
Very Truly Yours,
1 0A1XV441Z
Bennett Orlowski3O.0
Chairman
Cc. M.Verity, Building Department
/UXaQ _ 9_� _/.! TOWN OF SOUTHOLD PROPERTY RECORD CARDS /7- S
OWNER STREET VILLAGE DIST. SUB. LOT
FORMER OW ER E ACR.
b _ /,�1M i e 1�Ve. .3
S ii W TYPE OF BUILDING
,ES. SEAS. VL. FARM COMM. CB. MISC. Mkt. Value
LAND IMP. TOTAL DATE REMARKS M t /V E
0 or
h L
I
AGE BUIL NGC DITION
NEW NORMAL B OAK-, &�B E
i
FARM Acre V lue P vlo ue r
rillable 7 1
1 %r
Tillable 2
-illable 3
Voodland
,wampland FRONTAGE ON WATER
rushland FRONTAGE ON ROAD
louse Plot DEPTH
BULKHEAD
'otal DOCK
TOWN OF SOUTHOLD
---------------------------------•-------------------------X
In the Matter of the Application of
OWNER'S AUTHORIZATION
CELLULAR TELEPHONE COMPANY
d/b/a AT&T Wireless
Premises: Our Lady of Grace R.C. Church
No Number Oriental Avenue
Fishers Island,New York
SCTM# 1000-9-7-11.1
-----------------------------------------------------------X
STATE OF NEW YORK)
) SS.:
COUNTY OF SUFFOLK)"
ANDRZF7 WA<;2 GLCAI t2 being duly sworn, deposes and says:
The undersigned holds title to the premises known as District 1000, Section 9,Block 7,Lot
11.1 (the"Premises"hereafter),and do hereby authorize Cellular Telephone Company d/b/a AT&T
Wireless ("AT&T" hereafter) and its representatives to bring such applications for municipal
approvals as may be necessary for constructing or installing on the Premises such antennas,support
structures, and related equipment as AT&T may require for the establishment of its public utility
wireless telecommunication facility. As such, I will fully cooperate with AT&T and its agents in
obtaining any required Approvals.
eov-
(Owner's Si ature)
Swom to b ore me this
y o 02.
NOTARY PUBLIC
THO"116 F,p04"Y'Y lf1.
Notary Publle State of New York
No.46065W
QUaiifi0o in Sutfolk county
Term Expires 12131 ^
o�OgUFF0440
o
o� G1k
CIO :
Town Hall,53095 Main Road • .F Fax(631)765-1823
Southold,New York 1 971-0959 Telephone(631)765-1802
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
January 22, 2003
Lawrence Re A/C Omnipoint
36 North New York Avenue
Huntington, NY 11743
Dear Mr. Re:
Enclosed, please find your application for a wireless communications tower at Our Lady
of Grace Church, Oriental Avenue, Fisher's Island, Suffolk County Tax Map # 1000-9-7-
11.1. I have determined that you do not need a Notice of Disapproval from this office.
Please be aware, however, that you will still have to file an application with The Southold
Town Zoning Board of Appeals for a special exception.
If you have any questions about this matter, please call me at 631-765-1802.
ZRespe I +
Damon Peter Rallis
Building Permits Examiner
CC: File
05/26/2004 10:57 FAX 631 788 7798 FITELEP113NE 001
W2620
PysbM Island UMdy CO.
Drawer E
3%hers Island, NY 06390
631788 7251
Dates� ep
FAX#.�
From: /
Fax#631788 7798
Subject
Number of pates including tbis one
05/26/2004 10:57 FAX 631788 7798 FITELEFHONE IM002
ou
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING [ NAL
[ ] FIREPLACE & CHIMNEY
REMARKS:
67• x °
DATE INSPECTOR
1�
05/26/2004 10:57 FAX 631 788 7798 FITELCPHONE 0 003
FIELD hQSPEC1Z04�S REP.QBT DATE COMMENTS .
Ate�.++
5
FUVNDATION(151) A - ^y -
c
FOUNDATION(2ND) OC
2
c
'ROUGH FBAMA!iG R pmy
P`LVMSiLVG �
INSOLATION Y8R N.Y'. �
STA2Z 7A*rJ 'QGY CODA
MNAL
ADDMONAL COMMENTS
O
m
_ m
y
O
r_+
BUAKD OF HEALTH . . . . . . . . . . . . . . .
FORM NO. 1 3 SETS OF PLANS . . . . . . . . . . . . . . .
TOWN OF SOUTHOLD SURVEY . . . . . . . . . . . . . . . . . . . . ... . .
BUILDING DEPARTMENT CHECK . . . . . . . . . . . . . . . . . . . . . . . . .
TOWN HALL SEPTIC FORM . . .. . . . . . . . . . . . . . . .
SOUTHOLD, N.Y. 11971
TEL: 765-1802 NOTIFY:
hi
CALL . . . . . . . . . . . . . . . . . .
Examined........ 19:... ) 1f MAIL TO: . . . . . . . . . . . . . . . . . . . .
Approved....... �. LC.., 19.Z.°e�Permit No. ! �� ...
Disapproveda/c ............................. .. ....................................
....................................... .. ..........
(Building Inspector)
7 9n") APPLICATION FOR BUILDING PERMIT --'
Date. . . . . . . . . . . . . . . . . 19. . . .
INSTRUCTIONS
a. this application must be completely filled in by typewriter or in ink and submitted to the Building Inspector writ
3 sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public
streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of
this application.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Wilding Inspector will issue a Building Permit to the applicant. Such
permit shall be.kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of
Occupancy shall have been granted by-the Building Inspector.
APPLICATION IS tERERY MAIE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Tam of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for time construction of buildings, additions or alterations, or for removal or demolition, as herein
described. The applicant agrees to c6mply with all applicable laws, ordinances, building code, housing code, and
regulations, and to admit authorized inspectors on premises and in buildingfor necessary, inspections.
Cell e(Mailing
Company d/b/a AT&T Wireless
By . ................................
Ilicant, or name, if a corporation)
�S eekP.arks.Drive,Woodbury,.V.11-797
SFSkw.�q�c�l h� ress of applicant)
pm fM syr
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Lessee
..........................................................................................................."............
Our Lady of Grace R.C. Church
Nameof awner,of premises ............................
....................................
.......
........
.._.
...........
(as on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer.
.........................................................
(Nave and title of corporate officer)
Builders License No. ......................... .
Plumbers License No.
Electricians License N?_ ...........
Other Trade's License No. ....................
1. Iocation of land on which Cur. Lad of urace R.C. Church
proposedwork cell be done...........Y..................................................
No Number Oriental Avenue Fishers Island, New York 11957
................................................................................................................"......
House Naber Street Hamlet
Canty Tax Map No. 1000 Section .....9.......... Block .....Z......... Lot ... 11:1........
Subdivision ...................................... Filed Map No. ............... Lot ...............
(Name)
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy ...GbIkub...................................................................
b. Intended use and occupancy �nmdnR@d.P.U41J.G.uti]j.f.Y.fireless..tol�communi�atian.facili.ty...
consisting of antennas affixed to inside of church steeple and
related equipment cabinets installed in church basement.
Nature of work (check which applicable): New Building .......... Addition
It-pair ....... Removal ••.. Alteration ....... ...
..... ............. Demolition ............ ottherWorklnStdJ1.RU41i.G.Ut711tY.wirglests,
(Description etecommuins7deon
$120,000.00
Estimated Cost .........................
fee ............ church steeple..................................
(to be paid on filing this application)
If dwelling, number of dwelling units ..N/A...... dumber of dwelling units on each floor
N/A
Ifgara a. number of cars N/A
8
If business, commercial or mixed occupancy, specify nature and extent of each typeof use..Pr.....oposed Public UtilitY
...............
Dimensions of existing structures, if any: *Front................ Rear
Dept
* ee Plans Submitted Herewitfi.** Depth .""""""""
Neigiht idunbec of tories ........
Dimensions of same structure with alterations or additionsi Front .......
Depth ........ Rear ...............
P ...........•........ Neigtht .................... Number of Stories
. ...............
Dihrensions of entire new construction: Front
Rear ............... Depth ..............
lleight ......................... Number of Stories
. .....................
Size of lot: [Font .................... Rear .....
Deed dated December 27, 1956'**'*** "" Depth:r.......,.....
). Date of Purchase Recorded.1/14/51.. Nane of Former Owner West End Land Company, Inc.
.............................
�. Zone or use district in which premises are situated R;80, Residential Low Density
..........................
?. Does proposed construction violate any zoning law, ordinance or regulation: ........................
3. Will lot be regraded ...N(({,,,,.....,,, Will excess fill be removed from eahisea: YES
Our Lady of Grace Church Ori�ntal Ay�yenue NO
i. Names of Rorer of premises ....... Address FJS erS.1S.I.dO ,..NY........ Phone
No.
Name of Architect Wi l l i am F. Collins.,._AIA Address etau a hn o i ve ( """"'
TT �It pp 6...
Kr; �Y.� 7.f,........ Phone No.6JA-8.4.50....
Name of contractor _ Vantd�e 15 N. Mill St.
........................ Address Nyack,.NY.]0960.............Phone No.
i. Is this property within 300 feet of a tidal wetland? * YES ..........
*IF YES, SUMUD 1D{dt T[a1S1W PMUT HU HR 1ZC ABED. NO ..........
PLOT DIAGRAM
locate clearly and distinctly all buildings, whether existing or proposed, and indicate all set-back dimensions
nom property fires. Give street and block number or,description according to deed, and show street names and indicate
hether interior or corner lot.
See Plans.
PAPE or Nld Y(W,
)l1NlY Or .
SW 2�,� ..................being duly sworn, deposes and says that be _3r the applicant
indir'.tol signing contract:)
xrve nmmed,
is the ....Agent for Owner
..... ...... .... .... ......
. .....
(Contractor,. .....i
agent,. . .
corporate officer, etc.)...........................................
f said owner or owners, and is duly authorized to perform or have performed the said work and to make aril file this
pplicatioh; that all statements contained in this application are true to the best of his knowledge and belief; and
hat the work will be performed in the manner set forth in the application filed therewith.
worn to before me this m'
........2- ...:day of .. .\?"?nN1 `I� �P t?�—
' Cellular Telephone Company
Notary Public d/ /a AT& Wireless
.. ..
Notary """""""""""'
Public,State o/Ne
No. 52.4799664 rYYorlt (Si ture of Applicant)
uffolk
Comm shoran Expires May 3 � f
r
3 _ tl.+ h �¢v�I�PWLtir�'t" MMnayv
BUILDING PERMIT EXAMNER CHECK LIST
DATE RENEWED: /03
APPLICANT: C. 'DATE SUBMITTED:�5-,Qa/03
SCTM#
DISTRICT: 1,000, SECTION: ,BLOCK: �, LOT: SUBDIVISION:
ADDRESS g t Lff�CITY`--J�- �.ZONINGDISTRIM _CONFORMING?
BUILDING PERMITS OPEN/EXPIRED-
BP -Z/C/0 Z- , INFO /BP -Z/C/0 Z- , INFO
BP -Z/C/o Z- , INFO /BP -Z/C/0 Z- , INFO
PRE CO: Y OR N BP -Z/C/0 Z- ,
SINGLE & SEPARATE CERTIFICATION-REQUIRED n(o NOTES:
LATS 40,000SF-100-24.Lot recogni tion.(CREATED before June 30,1983),UNDERSIZED -25.Merger.(A nonconforming at any time after 7/1/,
REQ. LOT SIZE: ACT. LOT SIZE: Q. LOT COV. ACT. LOT COV.
REQ. FRONT PROP. FRONT REQ SIDE ACT. SIDE
REQREAR PROP. REAR REQ. HEIGHT PROP. HEIGHT
PROJECT DESCRIPTION: r `
ESTIMATED PROJECT COST: ARCHITEC E ^LvnJV
FAST TRACK _
WATERFRONT? A(lo DESCRIPTION:
PANEL #: FLOOD ZONE: , COMPLIANCE:
APPROVALS REQUIRED
SUFFOLK COUNTY HEALTH D T: YES or tl2jBED#): DTE: _/ /_ PERMIT#:
TOWN SEPTIC RECEIPT: Y or
NEW YORK STATE DEC: PRE-D 9n/75 YES o 0
SOUTHOLD TOWN TRUSTEES: S o 0
TOWN ZONING BOARD APPROV r NO
TOWN PLAN. BOARD APPROVAL• . r I 1
TOWN HISTORICAL PRE (SPLIA): YES or60
NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2) S or NO
NOTES:
FEE STRUCTURE: FOUNDATION: SF
FIRST FLOOR: SF
SECOND FLOOR: SF
OTHER: SF INIT OTHER TOTAL
TOTAL: SF FEE FEE FEE
1. ( —SF)- ( SF)= SFX $ =$ +$ +$ = $
2. ( SF)- (---SF)= SF X $ =$ +$ +$ = $
3. C_SF)- ( —SF)= SFX $ =$ +$ +$ = $
FINAL TOTAL: $
1
NEW YORK STATE CODE COMPLL ,NCE CHECKLIST
USE/OCCUPANCY CLASSIFICATION:
HEIGHT/FIRE AREA:
TYPE OF CONSTRUCTION:
DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE
FULL FRAMING DESIGN ELEMENTS:
HEADERS: Y/N WALL STUDS: Y/N
GIRDERS: Y/N CEILING JOISTS: Y/N
FLOOR JOISTS: Y/N ROOF RAFTERS: Y/N
LUMBER SPECIES AND GRADE: Y/N
DESIGN LOAD CALCULATIONS: Y/N
SHOULD INCLUDE LIVE,DEAD,SNOW,SEISMIC AND WIND(INCLUDING UPLIFT AND EXPOSURE)
WINDOW AND DOOR SCHEDULE:
MISSLE TEST REQUIREMENTS: Y/N
EGRESS, LIGHT, VENT: Y/N
LOAD PATHS: Y/N
ROOF TO FOUNDATION
NAILING/CONSTRUCTION SCHEDULE: Y/N
MEANS OF EGRESS: Y/N
PLUMBING RISER DIAGRAM: Y/N
LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N
TRUSS DESIGN: Y/N
CERTIFICATION: Y/N
ENERGY CALCS: Y/N
TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE)
VEDAS N�OTgE�D�7
B.P.I
FEE:
NOTES: /- NOTIFY BUILDING DEPARTMENT AT
765-1802 SAM TO 4 PM FOR THE
1 . THE FOLLOWING IS A PARTIAL LISTING OF ZONING DESCRIPTIONS OF THEFOLLOWING�j-FOUNDATION - TWO REOUIRED
TOWN OF SOUTHOLD: FOR PGURED CONCRETE_ WITH
PLYORK STATE & TOWN CODES
R-40 RESD NTIAUSLOW DENSITY AA MINESS o�TgUk �eNUe 3.4. FNALATIONCON NST1R `UCTI W �4 REQUIRED ANDCONDITIONS OF
R-80 RESIDENTIAL LOW DENSITY A
BE COMPLETE FOR C.O. � `7/2 3 �3 $OUTHOLD TOWN ZEA
ALL NETO
CORIICTION $HALL ME �(F $OUTHOLDTOWNPIANNINOBOARD
REO UIREMENT$ OF THCOpE$QFN
E N
O AX LOT.
OT DESSIGN OR CONSTRUCTION ERR II ` SOUIHOLD TOWN TRUSTEES
NOTE: Oa°'1°- S.DEC
INFORMATION SHOWN HEREIN IS BASED UPON A SURVEY PREPARED BY: BARRETT, B
BONACCI & VAN WEELE, P.C. CIVIL/ENGINEERS/SURVEYORS/PLANNERS, 175A TAN °T OQ/ ab"-0`5',11 TAX LOT T
COMMERCE DRIVE HAUPPAUGE, N.Y. 11788 (631 ) z-35-1022 (ON DECEMBER
27,2002 PROJECT NO: A021059
Q �COR
TAX L°T '°° ° OCCUPANTA} LOT I°°°-+°-e-e TAX L°T USE IS U FUL
1°°°-1°-e-s
°os eLOT1° WITHOUT CERTIFICAT
R - 4 0 OT °°°;o_ o^; OCC PANSY
100' RADIUS LIST OF OWNERS: ADDITIONAL OWNERS WITHIN 300': a -eTAX
1°.3 1°00 LOT
*1 , 1000-009-07-011 . 1 9. 1000-009-07-009 011 . 1000-009-04-022.02 11 . 1000-010-08-002 & 004 n e 0 LOTAXl;°a_e
OUR LADY OF GRACE RC CHURCH TIMOTHY W LAUGHLIN JOAN CHAVES EDMUND C & MARGARET HEDGE / u T. 2_ +
P 0 BOX 425 19142 EAST HINSDALE AVENUE 5 CARYN LANE P 0 BOX 297 GLNMAINE AVENUE ° 102 OD ZD
FISHERS ISLAND NY 06390 AURORA CO 80016 WEATOGUE CT 06089 FISHERS ISLAND NY 06390 J� /' ALPINE qVE [dV
USE: CHURCH USE: RESIDENCE USE: RESIDENCE USE: RESIDENCE / _ / •' ,' '•C ' .... •� NUE @ M�6r Wlfikl HAPTER 46
. . . . . . . . . . . . . .
2. 1000-009-04-023 2. 1000-010-08-003 °r l' '.'.'.'.'.'.'.'.'.'.'.'.'�'.' '.'.'.' ' '.'.'.'.' UNDERWRITERSCERTIFICA E §®dfkl®6H TOWN 0®®E,
I °°°-°-e-,e, / � � . . . . . .�.� . . . . . . ` o°d-„ REQUIRED
2. 1000-010-08-010.01 *10. 1000-009-07-009.02 SHILLO THOMAS JOHN C & VIRGINIA BEGGS I
RAYMOND A & ELIZABETH M YAKAITIS ALBERT H GORDON P 0 BOX 161 P 0 BOX 646
P 0 BOX 623 AL GRACIE SQUARE 4.'.'.'.'.'. ' . .'. .' HATCHED AREA IN ICATES
FISHERS ISLAND NY 06390 NEW YORK NY 10028 FISHERS ISLAND NY 06390 FISHERS ISLAND NY 06390 pyPIN E • • • • • • SUBJECT PROPER FOR
USE: RESIDENCE USE: VACANT
USE: RESIDENCE USE: RESIDENCE VENUE ' ' 000As �rili ` " 'a SITE PLAN SEE D TAIL 1 ,
ORI TAL A . . . . . . . . ..'.'.'.'.` SHEET SP-2
3. 1000-010-08-010.02 *1 1 . 1000-009-07-010 3. 1000-009-05-009 13. 1000-010-08-005 • • • • • • • • • • • • • • • • • • • • •� AU STRUOTIONSHALL
MARY GORDON ROBERTS ODIE & MARY K STRYNK °r f
+°°°-•-J-+° THEREOUIREMENTSOFTHE
MORTON L KENYON FISH -RS ISLAND LIBRARY 10 GRACIE SQUARE P 0 BOX 143 I I ' ' ' ' O
P 0 BOX 366 III LOT .'.'.'.'.'.'. M COL�ESOFNEWYORKSTATE.
c/o BETH CONNOLLY NEW YORK NY 10028 FISHERS ISLAND NY 06390 E-I T". L°T �,°�-e_,-1,r � • • •
19 FRANKLIN STREET FISHCRS ISLAND NY 06390 USE: RESIDENCE USE: RESIDENCE 00 . . . . . .'.'l'. .'. .
NEW LONDON CT 06320 USE: LIBRARY o . . . . . • . • . . . .,• . •�
USE: RESIDENCE 4. 1000-009-05-011 .011 14. 1000-010-08-006 & 007 0 RiF�
*12. 1000-09-12-007.01 246 M INC ANDREW J & SUSAN AQUILA I pp /
4. 1000-010-08-010.03 MARGARET M BOGERT 26 HIGH WOOD ROAD & DOROTHY MANNETTIu r"><°L°'r" '
JF
E "`""" '
JOHN H & DEBORAH A DOUCETTE EAST 66TH STREET BLOOMFIELD CT 06002 223 AVERY HILL ROAD P� O \ "N°LOi 16l R - 80
P 0 BOX 77 NEW YORK NY 10021 USE: HOTEL LEDYARD CT 06339 a
FISHERS ISLAND NY 06390 USE: RESIDENCE USE: RESIDENCE
AuLOr
USE: RESIDENCE 5. 1000-009-05-012 AV U�••
DAI LOTI-IIAN r° e •
MARY GORDON ROBERTS
5. 1000-010-08-009 ORIENTAL AVENUE
5. 1000-010-08-011 10 GRACIE SQUARE
ALEXANDER K & ELLEN R TAYLOR
JOHN C GOSS NEW YORK NY 10028
3425 OVERBROOK LANE USE: RESIDENCE N WALTER STREET \
NEWTON MA 02459 /
HOUSTON TX 77027 Z °r
USE: RESIDENCE � �°°°-°_J-e.z ��
USE: RESIDENCE 6. 1000-009-07-007 .Ax 2-71V
TAM LOT
1°°°_,_I
100°-9-J-J /
JOHN R & BARBARA (C KIMBERLY
7
6. 100-010-08-012 9225 GERMANTOWN AVENUE 16. 1000-010-08-013
FRANCIS KERNAN JR PHILADELPHIA PA 19118 ROBERT E & EG WALL
c/o INDELLI & COMPANY USE: RESIDENCE P 0 BOX 595 \ \ u69 /
5 OLD ROAD FISHERS ISLAND NY 06390
ELMSFORD NY 10523 7. 1000-009-12-006.011 USE: RESIDENCE
USE: RESIDENCE JOHN W METTLER III \ w
CORNELIA DALEY /
*7. 1000-009-05-016.01 950 3RD AVENUETAM L°T
ST JOHNS EPISCOPAL CHURCH NEW YORK NY 10022 \ \ 1O°°-° o�"-e O el /
FISHERS ISLAND NY 06390 USE: RESIDENCE
USE: CHURCH
8, 1000-009-05-017 8. 1000-09-12-008.01 \ /
HAY HARBOR CLUB INC
10 BOXX 195 GLEN J NORTON P O BOX 477
FISHERS ISLAND NY 06390 FISHERS ISLAND NY 06390 NPL w
USE: RESIDENCE USE: GOLF COURSE
* DESIGNATED AS LANDMARKS PER TOWN OF SCUTHOLD 9. 1000-010-08-001 .01 Y
HENRY H & LYNNE G FISHER O
712 MOUNTAIN ROAD w
WEST HARTFORD CT 06117
USE: RESIDENCE
tN
10. 1000-010-08-001 .02
HENRY LUCE III
720 5TH AVENUE SUITE 1500
NOTE:
NEW YORK NY 10019
USE: RESIDENCE IF THIS SHEET X 17",
REFER
KETO ADJACENT
GRAPHIC so' zoa
Y MAP CALE, NORTH
1"=100'-0"
_ Q
-_.__ FC PROJECT NO
Racy 02-4926 AT&T WIRELESS SERVICES
FISHERS ISLAND AT&T
WILLIAM F. COLLINS, AIA 903 006 201 v o
� � � ' ;', �� �* SITE PLAN AND NOTES
- A R C H I T E C T S, L L P Q 1/11/03 ISSUED FOR FILING PL, JM aE ' ,
ORIENTAL AVENUE AT&T WIRELESS SERVICES, INC.
10.1 TECHNOLOGY DRM SETAUKET,NY117;3 FISHERS ISLAND, NY 11957 NO. DATE REVISIONS By CHK APP'D u e JOB NO. SITE N0. DRAWING NUMBER REV
VOICE: 631-689.8450 FAX: 631-689.8451' 16 PARAMUS, NJ 007652 UE
SCALE: AS NOTED DESIGNED DRAWN: PL 24445 903006201 903 006 201 SP- 1 A
NOTES:
1 , ELEVATIONS SHOWN HEREIN ARE IN AN ASSUMED DATUM. d� AQP/l�Fq �
2. PROPERTY LINES SHOWN FOR FORMER TAX LOT 16 ARE BASED UPON TAX MAP,
DIMENSIONS ARE THEREFORE APPROXIMATE. THE EASTERLY LINE OF FORMER TAX
LOT 16, AS SHOWN WAS HELD PARALLEL WITH THE EASTERLY LINE OF FORMER
TAX LOT 11 , AS PER L.8499, P. 467. 0 s 36'°1'ao"
E
3. THIS SURVEY WAS PREPARED FOR A SPECIFIC PURPOSE AND IS NOT INTENDED
TO BE USED FOR A TRANSFER OF TITLE OR ANY OTHER FINANCIAL PURPOSE. Q 25 � (SEE NOTE
J�
4U.6
NOTE: ,�(/� ro ]61 449
INFORMATION SHOWN HEREIN IS BASED UPON A SURVEY PREPARED BY: BARRETT, s, 4
BONACCI & VAN WEFLE, P.C. CIVIL/ENGINEERS/';URVEYORS/PLANNERS, IL75A
COMMERCE DRIVE HAUPPAUGE, N.Y. 11788 (631 ) 435- 1022 (ON DECEMBER `° I o P
27,2002 PROJECT NO: A021059 `Q JI 106 4-5
W 5 G RACE �, 2a 0 61 STOR ,� I
/ ,U .56
NOTE: O
5]2 092
FOR KEY PLAN SHOWING ADJOINING LAND USES, STRUCTURES, ZONING LANDMARK 55,5
AND OWNERSHIP WITHIN 300' SEE DETAIL 1 , SHEET SP- 1 aa,5 o
y STOR'y a
ON
1
_ 44 o (ftE510ENGE)
p5 6 D„ T x LOT 1000-10-8-11
NOTE: N 5 25.000 / ° .2
LOT COVERAGE = 10% 1 Q R
(NO CHANGE)
44.2 O sa
LANDSCAPE COVERAGE = 88%
(NO CHANGE) TAX LOT 1000-9-7-10 h 1 4L7 DO
1 - 7- 1 . 5
4 R
as
J9.G
I 1
21 I 46
R >T
7 I I
PjE LU 1 O R L Y a e 5 RGGE GER
W000 IB.1 I
v 44B �/ T PORCH
pV� X /� LO RT & GRAVEL ARKING AREA 4e'6
.10 0 7- 11 )
e I EXISTING CHURCH BUILDING
2 a5 4 J5. �Qf
LL B
4G 5
2 R R C)
FRAME9.
1 STORY I Z
V BUILDING 40.4 . 1_i (CHURCH) a 1 W
41 ]
a ` 208SHADED AREA INDICATES NEW EQUIPMENT ROOM
oG� 4 � LOCATED IN CHURCH BASEMENT AND STEEPLE P PI
CONTAINING ANTENNAS ABOVE
^ 1R 'R� ' 5 B' 59'm'
V 'A 1Oy99, l� 3 444 247' ..
]]9 461 46.J I �I 1
e R
TAX Lor loon—to—a—lz
roR
4
'Qf� I 1 I III
O � ,
OUR LPC \
GRACE 6,5
CHH URCH
WORSHIP SCHEDULE I� Q N 3 109
(F M RL
F/I/G 61 s X 1 EXISTING CHURCH SIGN, SEE ELEVATION BELOW
F
SIGN ELEVATION
N T.S, v 375
I
9 I 1
Jv I
/V 2g.18 15 5
Ja a
2 \ I TN
sEE O .
\° NOTE:
IF THIS SHEET IS 11 " X 17",
ENLARGED SITE PLAN REFER TO ADJACENT GRAPHIC 0' 15' 30' Bo'
SCALE: i" = 30'-0"
S.0 T.M DISTRICT 1000 — SECTION 9 — BLOCK ] — LOT 11.1 SCALE. NORTH
Q
FC PROJECT NO
_ �To A 02-4926 AT&T WIRELESS SERVICES
FISHERS ISLAND _ AT&T
WILLIAM F. COLLINS, AIA. 90.3 '2
��s0') _
A R C H I T E C T S, L L F' ENLARGED SITE PLAN AND NOTES
ORIENTAL AVENUE Q 1/17/W ISSUED FOR PILING PL, JM AE n ;' _ .' �, ,ir
10.1 TECHNOLOGY DRIVE SErA[1IAT&T WIRELESS SERVICES, INC. - " -
VOICE: 631fi89-8450 FAR: 631-689-8459 FISHERSISLAND, NY 11957 15 EAST MIDLAND AVENUE No, DATE REVISIONS By CHK APP'D 226 ��1 ' JOB NO. SITE NO DRAWING NUMBER REV
PARAMOS, NJ 07652 SCALE. AS NOTED DESIGNED PRAWN: PL \-Up �I�� � %� 24445 903006201 903 006 201 SP-2 A
NEW 200 AMP "APPLETON"
EXISTING ELECTRICAL METER GENERATOR RECEPTACLE AT
MOUNTED TO EXTERIOR GRADE ABOVE
EXISTING LOUVERS TO BE REPLACED FACADE OF BUILDING AT BIG 1 4" NEW AT&T 200 AMP
1 2 WITH NEW RF TRANSPARENT LOUVER GRADE / POWER PANEL
NQ7',,�V PANELS, TYP. OF (3) LOCATIONS AT NEW 200 AMP AT&T �__
UPPER STEEPLE DISCONNECT MOUNTED EXISTING ELECTRICAL PANEL
BELOW NEW SUB-METER AND PLYWOOD BACKBOARD
EXISTING SMOKE DETECTOR
SECTOR "B" ANTENNAS MOUNTED NEW AT&T SUB-METER TO BE REMOVED AND
2 BEHIND NEW RF TRANSPARENT LOUVER REPLACED WITH NEW
P— P— �— _.._. _ _.
PANELS, TYP. OF ALL SECTORS NEW COAXIAL ANTENNA -
CABLES ROUTED ON SMOKE DETECTOR
I FUTURE
36'-4"f A.G.L. P UNISTRUT UP THROUGH w PTMA \ FRAME TO BEXISTING OERAND REMOVEEDOAND
84 'h -4"f A.'kS L. FLOORS TO STEEPLE � L
RAD. CL OF ANTENNA ABOVE N KAE F> REPLACED
IDOOR TH EAND
-0
EXISTING CEILING SYSTEM PET ASITEI FRAME, TYP.
31 '-0"f A. .L. TO BE REMOVED AND LCA INET
REPLACED WITH NEW DASHED LINES INDICATE SECTION
X79'-0"f A.l"f A.I �.S.L. 1 1 2" HR. FIRE RATED OF EXISTING DOOR JAMB, WALL
FLOr OR OF ZIPPER
STEEPLE — CEILING AND DOOR TO BE REMOVED
_ NEW THROUGH WALL -- EXISTING WOOD PLANK FLOORING
9'-8"f A.( ',.L. EXHAUST FAN TO TO BE REMOVED. SEE NOTE THIS
' t L. = REPLACE EXISTING DETAIL
X67'-8A.1A.( ;,L.
FLOOR_ OF LOWER r — WINDOW AND FRAME
NEW 48"x48" TELCO
STEEPLELBACKBOARD
_
NEW COAXIAL ANTENNA CABLE ------------
DASHED LINE INDICATES
--
ROUTED ON UNISTRUT UP THR )UGHEXISTING CHURCH ORGAN
1 NEW 3'-0" LOUVERED PUMP TO BE RELOCATED
P_ FLOORS FROM NEW AT&T EQUIROOM IN BASEMENT TO UPPER MENT DOOR i WITHIN ROOM IF NECESSARY
i �
STEEPLE ANTENNAS ABOVE-
1 '-7"t A.C .L. REMOVE EXISTING ALUMINUM r STORE
49'-7"t AM.S.L. SCREEN DOOR
I � 2" NEW FULL HEIGHT 2 HR.
TO EQUIP. _ TEXISTING STORM DRAIN TO BE t i' 1 '-4' FIRE-RATED
ROOM CLG, CLEARED OF DEBRI AND To SHAFT WALL, TYP.
0'-0"1 BE MADE FUNCTIONAL I!
"n
48'-0' f A M.S.L. EXISTING STAIRS TO DASHED LINES INDICATE SECTION
GRr ADE EXTERIOR GRADE FROM
NEW AT&T EQUIPMENT OF EXISTING DOOR JAMB, WALL
ROOM AND DOOR TO BE REMOVED, TYP.
EXISTING HAND
-6'-2"± E ,G.L. BELOW GRADE ENTRANCE TO RAILING
41 '- 10"t"t A.M.S.L. NEW AT&T EQUIPMENT ROOM
EQY UIP. ROC M F.F.E. IN BASEMENT
,,6,
CONTRACTOR TO REMOVE EXISTING WOOD FLOORING
SYSTEM DOWN TO EXISTING CONCRETE SLAB. EXISTING k
CONCRETE SLAB TO BE PATCHED, REPAIRED AND NOTE:
MADE LEVEL PRIOR TO PLACEMENT OF NEW VINYL IF THIS SHEET IS 11 X 17",
COMPOSITE TILE FLOORING. REFER TO ADJACENT GRAPHIC
SCALE.
NORTH/EAST ELEVATION f� ENLARGED BASEMENT EQUIPMENT PLAN 1,33' 2.66' 533' NORTH
1 SCALE 1/8" = 1' 3/8"-Y
FC PROJECT NO
FISHERS ISLAND AT&T4 ,y 02-4926 AT&T WIRELESS SERVICES
WILLIAM F. COLLINS, AIA 903 006 2010
ARC R I T E C T S, L I, P ELEVATION AND DETAILS
ORIENTAL AVENUE Q 1/17/03 ISSUED FOR FILING FE, JM AE
O1
10-1 THCHNOfAOY DRIVE BETAOKET,NY 111!)3 FISHERS ISLAND, NY 11957 15 EAST MIDLAND AVENUE AT&T WIRELESS SERVICES, INC. No, DATE REVISIONS BY CHK APP'o ��E Or t^ -iJOB N0. SITE N0, DRAWING NUMBER REV
VO7C8: 631699-8450 FAR: 631.689-9450 PARAMUS, NJ 07652
SCALE As NOTED DESIGNED DRAWN: PE 24445 903006201 903 006 201 SP-3 A
•
AT &T
D
AT&T WIRELESS SERVICES , L . L . C .
SITE NUMBER : 903 006 201
SITE NAME : FISHERS ISLAND
DIRECTIONS
DRAWING INDEX REV, TAKE LONG ISLAND EXPRESSWAY(495) EAST TO EXIT 73. CONTINUE ON TO ROUTE 58 EAST, IT WILL TURN PROJECT INFORMATION
INTO ROUTE 25 EAST. FOLLOW SIGNS TO TRUCK ROUTE 25 (ALDRICK LANE), TAKE NORTH TO TRUCK ROUTE
25/CR 48 EAST. CONTINUE ALL THE WAY TO THE END. TAKE THE "ORIENT POINT FERRY" TO THE FERRY
903 006 201 T- I TITLE SHEET B TERMINAL IN NEW LONDON, CONNECTICUT. TAKE THE "FISHERS ISLAND FERRY" FROM NEW LONDON, CT. TO SCOPE OF WORK: AN UNMANNED TELECOMMUNICATIONS FACILITY INCLUDING
FISHERS ISLAND. DRIVE OUT OF FERRY TERMINAL AND TURN LEFT ONTO GREENWOOD AVE. AT THE END OF TELECOMMUNICATION EQUIPMENT IN BASEMENT AND
903 006 201 A- I PIANS AND NOTES B GREENWOOD, MAKE A LEFT ONTO WHISTLER AVE. CONTINUE ON WHISTLER AVE. UNTIL YOU GET TO RELATED ANTENNAS MOUNTED IN STEEPLE. C
EQUESTRIAN BLVD. MAKE A RIGHT ONTO EQUESTRIAN BLVD. UNTIL IT MEETS WITH OCEAN VIEW DRIVE. SITE ADDRESS: ORIENTAL AVENUE
903 006 201 A-2 ELEVATION, ENLARGED EQUIPMENT PLAN, A CONTINUE ON OCEAN VIEW DRIVE TO NEATHULIE AVE. MAKE A RIGHT ON NEATHULIE AVE. CONTINUE ON FISHERS ISLAND, NY 11957
NEATHULIE AVE. TO ETTRICK ST. AND CONTINUE STRAIGHT ACROSS ORIENTAL AVE. TO OUR LADY OF GRACE
AND ARCHITECTURAL DETAILS CHURCH ON EAST SIDE OF ORIENTAL AVE. PROPERTY OWNER: OUR LADY OF GRACE CHURCH
903 006 201 A-3 ARCHITECTURAL DETAILS B PHONE: (631 ) 788-7353
903 006 201 A-4 ARCHITECTURAL DETAIL! f VICINITY MAP ADDRESS: ORIENTAL AVENUE, FISHERS ISLAND, NY 11957
A "''Vilp t i,'r- '1.;�i1 ' '1 u1u°Vitt i ' 1'11 , 11v'.' ' 1a i I `t'i{ 111"I 'dIl"I ll'21,11111 ''r''h°I+ +y't-ttw,l1:" �s� ' qn, 1,';,1; CONTACT PERSON: BILL GLENDON, (ATTORNEY)
1d IYI IIS M 1 � Y � �vl I , 1 � Ir iu it I " I , II 1,11 it i
z, ' e a a �I 1111 VI � Y1 i -, !ul r 1 , 1 t. t ) fii#'�e,�ll + ' + I In ray llt'd11 � +IlIF
903 006 201 E- I ELECTRICAL RISER DIAGR \MS AND ELECTRICAL NOTES B h ' a l3 iu ,III ' I''li' ' T 4 ,, !1 "'' PHONE: (914) 725-3442
,$it ,�. 4 xl ysv se a i 'I Ir '1 'I{FF ` ' �ry �' '
pl .".,''
Jlll.,l,Ik,F11 ,.FI'!J'4 11 tn'1?I,1+:11Y'61x {. l,r 1 ,4x"1�1 LgIlI y
APPLICANT:
903006201 E-2 ELECTRICAL DETAILS NOTES A
AT&T WIRELESS SERVICES, INC,
15 EAST MIDLAND AVENUE
lulli h- d1 ili lll.'1n ill, I4s'Ir�IM1 ,I;ISvJ{I r, '11,11 1� , : ' it 1 ,II�IV 't1"1111 ` ' fi''.i� : i 1,,.in r- F 'l 5 E19b J' `F, F';4
903 006 201 E-3 TELCO/ELEC/GROUNDING PLANS, NOTES AND DETAILS B 1 ; 1 ti,' PARaMus, NJ 07652
Pi Ign iillilitl,,'�'ii �I � ' I! {l ,✓t a, v"IF u� : I I: 1 , I x v -++i+ "t ., 1 W4!,�ys�'
- A rYsl , , IFrv1j+Lt�is1 , iy_ t a, -:,1} i �^','�ftliil`„li , ,ij: ttl' SvJyl.., Il : II� '_: .^t , [F` , ['Itiy �" '�uil}�, .� LATITUDE: 41' 15' 39.6„
903006201 E 4 ENLARGED LIGHTING/ELI :CTRIC PLANS, AND A fl,, , ,Y r ;s E lr,,l{ 4 IJ. G y
v'1i: 1 , ,., a-:: 3 t„Ir u„ k"AC art 17* `; �'a
LONGITUDE: 72' 00' 31 . 1 „
GROUNDING DETAILS
ELEVATION: 49'-0" AMSL*
6 P cNnIF, 1, ` f{y'1,�: I � ,iV H'y. r ^HI 11 ty''ti h` lir lkla l' .. q' t Vul .vtl ' r 'a -
903 006 201 E-5 ANTENNA CABLING SCHEMATIC AND DETAILS B ;l lY 'I h'�°Ir!+,ra,1 1t111� 11 „N glia Ic, 1 i..1 1L, 111 1;r , ; ;.,! , -11 I' � ' . �` , fi . m? JURISDICTION: OWN of SOU
rHOLD
_M1r m ly �iiill l�IlII pry6- t rt, F�,' ', 1iy + ,. a 1{.
'�7MP TAX I.D. NUMBER: SECTION: 9 BLK: 7 LOT: 1 1 . 1
ZONING DISTRICT: R-80
� .Cr `"• '•. �I III, 1.�, " ,1 !�r� , :',1 , ' r I� r ) 1 Iu II'"�+� if eTl� � -u' I ,.[ tra tier
CURRENT USE: RESIDENTIAL BUILDING
'�11''71�11 Pi��,I�7,�p,I1 .I�IR� � t , dU�VP�N r,Id�' 19x11 +'-`, I Ii11q:bV!hMl P11vrP : M .. " I'I rl !'�11� il�V r�y:�llr 'y11 'i 1
PROPOSED USE: RESIDENTIAL BUILDING
14q'°�', �II'I� 1�1�It�+14J�'uG Vr ,a.. II ,N RII II r�4 , r B
f y all li ti w I I. r,r i I II 1 le
*THE REFERENCED AMSL INFORMATION SHOWN HEREIN HAS BEEN OBTAINED UTILIZING 3-
D
TOPOQUADS TOPOGRAPHIC MAPPING SOFTWARE BY "DELORME". ACTUAL ELEVATIONS MAY VARY
„n1 >rtia11 M11 i rVlll It 'K 1. y r i1� Itli '. 1 tlt, 1 , I�11�s t, A 4 , l ll ,,;�
;`� ' �' Iii; 11o•r+I' � loeiih � r A � I r I 111+ � II � u 1 ,,,,. 1, I,re I; API p� a' � �" a J i � ! ACCORDING TO POINTS OF REFERENCE.
7
11Iwl�^ I r rJ t"1 : I I 1 1 1 1. I i b II 11a, 1111 �r a 4 n: ISK'I I 51,i1x.vf.� p tli 11 11'Ir 1[`' i '
1'li; lil �gi 11 -Iiy 191 Wli itl'pifiil rll 'Va"'V 11 ',tial"I II , u1 ,I 1 ..I Id1II ' .' 1 , �1j1 �I , f�/. V 1, ilrva
, '"�'}I. 1�4„77 I,1 Y� .!,mh1`t 1. I�i 1�, It 1_V 1 ,1 Illli'!1n11111,1 �{i.AJil sr1(i�'.,I I ,dill ' ,I.j:)JII 11� 6,11ya 'si�.�L�lr I'7i l dil 1'4 rill'"
I'Y'j41I''�1(
't.;"
� SITE QUALIFICATION PARTICIPANTS
11 I d I " � i III Ile{'' 11 �' !: � I "I �' °.II 11 IfIU° 1 ✓t ,4,, 11 IP 'i1t1 ,Ili I S=e,
9111,1 'IIVI 1i,[r I.2 :�' 111x16 igirf 9 e 111'6'. lel7�v-, �.'fA{111 ,171 4,' i n MI P lql,, ih�ll�'I��J. 1 t 14. II I, 1 1 h it l rl'r Qn:l, W f 1,1. 1 .(r 1 p;.,
NAME COMPANY NUMBER
ill-.,�- 7 "LOv r [il„ 1i,l�r l,�fe'i .v1. lu I1'yl rr,i 11 l�:� .d��''I'ill,
N { - , :,lrr ;:? li 11 .5. :';I�ir' h b' i�J ,I1 y ,'I�f'ii '','IJi111i Ila r��C'i
r ,,a .a+ llj a Inrl,lusl ,u�l;:i'.!.!;h, ul lhr !ul.rx, 111111, li;.l. itrll :orm +r1 � ' � ;hl ` ` ' ��� 1 I I �,' � NEIL A. MACDONALD WILLIAM F. COLLINS, AIA ARCHITECTS, LLP (631 689-8450
el1'yI II��'iJI u11 f II �i P It, 1 111i11 ,h a ylll l 11 a 1' Lr )
l 1
ty
ts4' ;Il' SAC MATT BARTLETT HIGHLANDER CONSULTANTS INC. (631 ) 581 -8105
} tUi4 YlJr. yh' a +' iii r 1x11 1: II 11111+ i '1v tq vu'1i a,�l .1r 1, Lsi�11111 { _'9P ul n11'I: i 1
RF SERHAD GUVEN AT&T (201 ) 336-3696
i'. , .., .,t:. ,;,r sr�� CON JOHN THEISSEN BECHTEL TELECOMMUNICATIONS 631 753-6143
' (jjtB,•EI[ to}g "AA 1 k' 6u t ' nroJ111 III 1 pr, t 'v 4 rN� 1 1 a 1 .r;pl A l 11 i_tl� ,�, a iN}p1 l l ryif, Irl ( 11. 4' ivi'41(¢ i ( )
ljlrA9hr`,3i , 1. fE It ,, li - _ ':',Li 1 �kul, id I I:-nlll'1��I,� II ;:� 1- 1. � IrI' A
LANDLORD N/A N/A N/A
Q FC PROJECT NO
"
FISHERS ISLAND DER
Ai ti, 02-4926
AT&T WIRELESS SERVICES
=--.- o :�y
WILLIAM F. COLLINS, AIA 903 006 201 AT&T
-
-m2l - - A R C H I T E C T S, L L P 0 s/is/o} slued FOR zoN1Nc Ac,au AF n
' * TITLE SHEET
ORIENTAL AVENUE 10/30/02 ISSUED FOR REVIEW PL AF II
1al lEc@Ioc oar 50 sa X: 631,N9.9459 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. NO, DACE REVISIONS By CHK APP'O 06 JOB NO. SITE NO. DRAWING NUMaER Rev
VOICE: 631-639-8450 PAX: 631fi89�8459 75 EAST MIDLAND AVENUE �J��� f„
PARAMUS, NJ 07652 SCALE AS NOTED DesicNED DRAWN. xsx 24445 903006201 903 006 201 T- 1 B
5 4 3 2 DFN=STV[160,021 .DWG 22 H 34 T SIZE
6
PSC= .
—= _
-----------
1900 TX/RX 1900 TX/RX
NOTES: CELL SITE INSTALLATION NOTES:
1 . ALL MATERIAL ON THE TABLE BELOW SHALL
BE PROCURED BY BECHTEL. THE FOLLOWING INSTALLATION NOTES HAVE BEEN COMPILED FROM THE 1 . ALL ANTENNA COAXIAL CABLES AND JUMPERS SHALL BE INSTALLED WITHOUT
EXISTING PROJECT DOCUMENTS (I.E. PROJECT SPECIFICATIONS, EQUIPMENT LOOPS AND/OR PIGTAILS.
2. THE CONTRACTOR SHALL NOT EXCEED THE VENDOR DOCUMENTS, ETC.) FOR USE. THESE NOTES SHALL BE UTILIZED FOR
CABLE LENGTHS SHOWN ON THE DRAWING THE CONSTRUCTION OF THE CELL SITES TO ENSURE COMPLIANCE WITH THE
WITHOUT RF ENGINEERING APPROVAL. PROJECT DESIGN AND SPECIFICATION REQUIREMENTS. 2. ANTENNA COAXIAL CABLE GROUND KITS SHALL NOT BE INSTALLED ON THE
3 LISTED ARE AREAPPROXIMATIONS A. GROUNDING: JUMPER BETWEEN THE ANTENNA AND MAIN LINE CABLE.
DUALPOLE SECTOR BASED ON THESE
ANTENNA, TYP, LAND LINK PARABOLIC INTENDED TO BE USED FOR ORDERING CABLE. 1 . ALL METAL CONDUIT FOR GROUNDING DOWN CONDUCTORS SHALL BE BONDED N
3. ANTENNA COAXIAL CABLE GROUND KITS SHALL BE INSTALLED AS CLOSE TO
ALL CABLE LENGTHS MUST BE V.I.F. T BOTH ENDS. D
TO THE GROUND SYSTEM A
DISH ANTENNA THE CONNECTOR AS POSSIBLE AT EACH ANTENNA. IF THIS IS NOT FEASIBLE
7/16" DIN TYPE FEMALE 2. GROUNDING CONDUCTORS SHALL BE CONNECTED TO THE MAIN WATER PIPE THE GROUND KIT SHALL BE INSTALLED IMMEDIATELY AFTER THE BEND ON THE
CONNECTOR (ANTENN4) 4. COLOR CODE ALL MAIN USING A BURNDY TYPE GAR—TC CLAMP.
CABLES AT TWO LOCATIONS: FIRST STRAIGHT RUN OF CABLE. THE GROUND KIT SHALL BE INSTALLED ON
TOP JUMPER CABLE 5/8" DIN TYPE "N" NEAR ANTENNA, 3. KOPR—SHIELD ANTI—OXIDATION COMPOUND SHALL BE USED ON ALL STRAIGHT SECTION OF CABLE ONLY AND NOT ON BENDS.
MA FEMALE CONNECTOR NEAR EQUIPMENT GROUNDING CONNECTIONS.
(IF REQUIRED) (ANTENNA) 4- ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE 4. ANTENNA COAXIAL CABLE SHALL BE INSTALLED TO COMPLY WITH THE
5. ANTENNAS SHALL BE PROCURED AND CADWELD PROCESS. MANUFACTURER'S MINIMUM BEND RADIUS SPECIFIED IN THE FOLLOWING TABLE,
INSTALLED WITH DOWNTILT BRACKETSAND THE CONTRACTOR SHALL INSTALL RACEWAY FOR COAXIAL CABLE USING THE
HEAVY DUTY CLAMPS SUPPLIED BY ANTENNA 5- ALL CADWELDS SHALL BE INSTALLED USING THE PROPER CONNECTION/MOLD PROPER FITTINGS NECESSARY TO ENSURE THAT THE MINIMUM BEND RADIUS
MAIN COAXIAL CABLE MANUFACTURER UNLESS OTHERWISE NOTED, AND MATERIALS FOR THE PARTICULAR CONNECTION AND/OR APPLICATION, REQUIREMENTS ARE MET. POVIDE A DRIP LOOP AT ANTENNA.
6. TOP AND BOTTOM JUMPERS SHALL BE
SUPPLIED AND INSTALLED BY THE EQUIPMENT TEE CONNECTION SWEEP CONNECTION POST CONNECTION
GROUND BAR O� MAIN COAXIAL CABLE MANUFACTURER. COAXIAL CABLE MINIMUM BEND RADIUS
(NEAR ANTENNAS) —aZ ANTENNA POST
7. CONTRACTOR SHALL VERIFY ANTENNA TYPE CADWELD
GROUNDING KIT 34 AND AZIMUTH WITH CONSTRUCTION MANAGER rCADWELD CABLE SIZE MINIMUM BEND MINIMUM BEND RADIUS IN
E—a PRIOR TO STARTING CONSTRUCTION. MANUFACTURER CABLE TYPE
#2 AWG BCW i CADWELD #2 AWG BCW (DIAMETER) RADIUS IN TRAY 4" OR 6" CONDUIT
8. CONTRACTOR SHALL PROVIDE AN #2 AWG BCW SL�
AGROUND BAR 509 INDEPENDENT TESTING AGENCY TO PERFORM ANDREWS LDF5-50A 7/8" 10° CONTACT COAX MANUF.
GROUNDING KIT 5134 j E—a
El-34 (NEAR ANTENNAS) COAXIAL SWEEP TEST AND REPORT, AND ANDREWS LDF6-50 1 1 4" 15" CONTACT COAX MANUF.
PROVIDE THE NECESSARY QUALIFIED /
PERSONNEL AND EQUIPMENT NEEDED TO 6. ALL BOLTED GROUNDING CONNECTIONS SHALL BE INSTALLED WITH A LOCK
GROUND BAR ASSIST IN ANY REPAIRS AND WEATHER WASHER UNDER THE NUT. HARDWARE FOR BOLTED CONNECTIONS SHALL BE ANDREWS LDF7-50A 1 5/8" 20" CONTACT COAX MANUF.
(AT EQUIP.) 501 PROOFING. CONTRACTOR IS TO PROVIDE MINIMUM OF 3/8" DIAMETER AND SHALL BE STAINLESS STEEL.
BECHTEL WITH A MINIMUM OF 48 HOURS C
#2 AWG INSULATED NOTICE PRIOR TO TIME OF SWEEP TEST AND 7. OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISHING A "CHOKE" POINT. 5. ALL ANTENNA COAXIAL CABLES SHALL BE MARKED IN ACCORDANCE WITH THE
#2 AWG INSULATED GROUND WIRE FURNISH RESULTS WITHIN 48 HOURS OF GROUNDING WIRE SHALL NOT BE INSTALLED OR ROUTED THROUGH HOLES IN REQUIREMENTS IN BECHTEL ENGINEERING STANDARDS DOCUMENT
GROUND WIRE COMPLETION. ALL SWEEP TESTING TO BE
COPPER PLATE DONE IN ACCORDANCE WITH SPECIFICATION ANY METAL #24445-801 -3DS—GET-0002-001
SECTION 24.
5 EQUIPMENT GROUND BAR 6. THE CONTRACTOR SHALL ORIENT THE COAXIAL CABLES ON THE ICE BRIDGE TO
. 5os 9. ALL INDICATIONS OF NORTH ARE FOR MATCH WITH THE ORIENTATION OF THE COAX ENTRY HATCH PLATE ON THE
BASEMENT (AT EQUIP,) E—a REFERENCE ONLY. CONTRACTOR TO VERIFY SHELTER.
IN FIELD TRUE NORTH PRIOR TO SECTOR
4 EQUIPMENT ANTENNA INSTALLATION. 7. ONLY ANDREWS GROUNDING KITS SHALL BE USED ON ANDREWS CABLE. THE
FOLLOWING IS A LIST OF PART NUMBERS FOR GROUNDING KITS.
6
BOTTOM JUMPER CABLE —A #2 AWG BCW NOMINAL ANDREWS
DEPICTS CHOKE POINT (NOT ACCEPTABLE) CABLE SIZE ANDREWS STANDARD
LAND LINK ALPHA SECTOR BETA SECTOR GAMMA SECTOR TOTAL (DIAMETER) CABLE TYPE
( ) GROUND KIT
TEM ITEM DESCRIPTION AZIMUTH 36. 15' AZIMUTH 70' AZIMUTH 240' AZIMUTH 310' QUANTITY
N0. 8, FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUNDING 7/8" LDF5-50A SGL5- 1084
TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX (SEE NOTE 1 ) CONDUCTOR SHALL NOT BE USED. CLIPS OF THE FOLLOWING MATERIALS AND
1 ANTENNA ANDREW ALLGON ALLGON ALLGON ALLGON ALLGON TYPES MAY BE USED TO FASTEN AND SUPPORT GROUNDING CONDUCTORS. 1 1 /4" LDF6-50 SGL6-1084
(SEE NOTE 5) 5+ 1
AS—BUILT SERIAL #
P3F-52 7250.03 7250.03 7250,03 7250.03 7250.03 1 5/8" LDF7-50A SGL7-10134
_
MECHANICAL UPTILT 0.06' 0' 0' 0' 0' O' PLASTIC CLIPS
ANTTEONNA WNTILT JUMPER 8, SNAP—IN HANGERS USED FOR 7/8" ANDREWS CABLE SHALL BE ANDREWS
LDF4-504 LDF4-504 LDF4—SOA LDF4-504 LDF4-504 30 FT SNAP—IN HANGERS. SNAP—IN HANGERS USED FOR 1 1 /4" AND 1 5/8" B
2 (ANDREW) N/A 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2'" (6 FEET) 1 /2" (6 FEET) ANDREWS CABLE MAY BE ANDREWS SNAP—IN HANGERS R EQUIVALENT
(LENGTH) ° METAL CLIPS WHICH DO NOT COMPLETELY SURROUND THE GROUNDING HANGERS FROM ANOTHER VENDOR.
ATTACHED MALE DIN INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED CONDUCTOR
2A CONNECTOR L5PNM—RPC W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2
(ANDREW) 9. HOISTING GRIPS USED FOR 7/8", 1 1 /4" AND 1 5/8" ANDREWS CABLE MAY
MAIN COAX BE ANDREWS OR EQUIVALENT HOISTING GRIPS FROM ANOTHER VENDOR. FOR 1
3 (LENGTH) (1 ) 5/8°0(65') (2) 7/8"065') (2) 7/e"0(72') (2) 7/8"0(72') (2) 7/e"0(85') (2) 7/8"0(85') 758 FT m 5/8" COAXIAL CABLE, A STAINLESS STEEL HOSE CLAMP MUST BE INSTALLED
(ANDREW) LDF4.5-50 LDF5— OA LDF5-50A LDF5-50A LDF5— DA LDF5-50A + 65 FT
WITH THE HOISTING GRIP.
• UNATTACHED FEMALE 9
4 DIN CONNECTOR T.B.D. L7PDF—RPC L7PDF—RPC L7PDF—RPC L7PDF—RPC L7PDF—RPC 10
(ANDREW) STANDARD GROUND BARS SHALL BE FURNISHED AND INSTALLED. THEY SHALL C . MANUFACTURED MATERIAL:
UNATTACHED MALE 10. NOT BE FABRICATED OR MODIFIED IN THE FIELD.
5 DIN CONNECTOR T.B.D L4PDM—RPC L4PDM—RPC L4PDM—RPC LdPIDM—RPC L4PDM—RPC 10 ALL GROUND WIRES SHALL BE INSTALLED WITHOUT LOOPS (PIGTAILS) AND 1 . WHEN SPECIFIC MANUFACTURER'S ITEMS ARE SPECIFIED, THEY MAY BE
(ANDREW) SHARP BEND RADIUS.
ANTENNA JUMPER REPLACED BY SIMILAR, EQUIVALENT ITEMS WITH PRIOR ENGINEERING APPROVAL,
LDF4-504 LDF4-504 LDF4-504 LDF4-504 LDF4-504 LDF4-504 36 FT
6 (ANDREW)
/2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET)
(LENGTH) B. ANTENNA COAXIAL CABLES (WAVEGUIDE)
7 ID TAG ALPHA 2 ALPHA 1 BETA 1 BETA 2 GAMMA 1 GAMMA 2 NOTE: THE RF TRANSMISSION LINE INSTALLED BETWEEN THE RADIO CABINET,
8 COLOR CODE THREE GREEN ONE GREEN ONE BLUE THREE BLUE ONE WHITE THREE WHITE FURNISHED BY RBS EQUIPMENT SUPPLIER, AND THE ANTENNA CONSISTS OF A
TWO GREEN TWO BLUE FOUR BLUE TWO WHITE FOUR WHITE COAXIAL CABLE, SOMETIMES REFERRED TO AS A WAVEGUIDE.
ANTENNA SC WE
A
1 SCALE: N.T.S.
Ec PROJECT No AT&T WIRELESS SERVICES
- «_ 02-4926
FISHERS ISLAND "�
c 'nom
WILLIAM F. COLLINS, AIA 903006201 0 s/ts/w ssued roR zaNiNc Ac.d AE ANTENNA CABLING SCHEMATIC
_ A R C H I T E C T S, L L P
ORIENTAL AVENUE Qn io/aD/oz issued FOR REVIEW PL i AE Tr Aa_ AND DETAILS ,
lo-1TECHNOLOGY DRIVE SETAUKET,NY11739 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. NO. DATE REisloes ev cNN APP'o r, 0269" O Job NO. SITE ND. DRAWING NUMBER REV
15 EAST MIDLAND AVENUE \6 I��
VOICE: 631-689.8450 FAX: 631fi89-&159 PARAMUS, NJ 07652 SCALE: As NOTED DESIGNED DRAWN: zxx �� 1� 24445 903006201 903 006 201 E-5 I B
6 4 3 2
DEN=srV[160,021 Dwc 22 x 34 D SIZE
5
PSC,=
li
—8 Mpg
AT &T
D
AT&T WIRELESS SERVICES , L . L . C .
SITE NUMBER : 903 006 201A
SITE NAME : FISHERS ISLAND
DIRECTIONS
DRAWING INDEX REV. TAKE LONG ISLAND EXPRESSWAY(495) EAST TO EXIT 73. CONTINUE ON TO ROUTE 58 EAST, IT WILL TURN PROJECT INFORMATION
INTO ROUTE 25 EAST. FOLLOW SIGNS TO TRUCK ROUTE 25 (ALDRICK LANE), TAKE NORTH TO TRUCK ROUTE
25/CR 48 EAST. CONTINUE ALL THE WAY TO THE END. TAKE THE "ORIENT POINT FERRY" TO THE FERRY
903 006 201 T— I TITLE SHEET I TERMINAL IN NEW LONDON, CONNECTICUT. TAKE THE "FISHERS ISLAND FERRY" FROM NEW LONDON, CT. TO SCOPE OF WORK: AN UNMANNED TELECOMMUNICATIONS FACILITY INCLUDING
FISHERS ISLAND. DRIVE OUT OF FERRY TERMINAL AND TURN LEFT ONTO GREENWOOD AVE. AT THE END OF TELECOMMUNICATION EQUIPMENT IN BASEMENT AND C'
903 006 201 A— I PLANS AND NOTES I GREENWOOD, MAKE A LEFT ONTO WHISTLER AVE. CONTINUE ON WHISTLER AVE. UNTIL YOU GET TO RELATED ANTENNAS MOUNTED IN STEEPLE.
EQUESTRIAN BLVD. MAKE A RIGHT ONTO EQUESTRIAN BLVD. UNTIL IT MEETS WITH OCEAN VIEW DRIVE. SITE ADDRESS: ORIENTAL AVENUE
903 006 201 A-2 ELEVATION, ENLARGED EQUIPMENT PLAN, I CONTINUE ON OCEAN VIEW DRIVE TO NEATHULIE AVE. MAKE A RIGHT ON NEATHULIE AVE. CONTINUE ON FISHERS ISLAND, NY 11957
NEATHULIE AVE. TO ETTRICK ST. AND CONTINUE STRAIGHT ACROSS ORIENTAL AVE. TO OUR LADY OF GRACE
AND ARCHITECTURAL DETAILS CHURCH ON EAST SIDE OF ORIENTAL AVE. PROPERTY OWNER: OUR LADY OF GRACE CHURCH
PHONE: (631 ) 788-7353
903 006 201 A-3 ARCHITECTURAL DETAILS I VICINITY MAP ADDRESS: ORIENTAL AVENUE, FISHERS ISLAND, NY 11957
903 006 201 A-4 ARCHITECTURAL DETAILS 0 t CONTACT PERSON: BILL „GLENDON, (ATTORNEY)
1 •I k1 �y\,��! 1� � I I I I
903 006 201 E— I ELECTRICAL RISER DIAGIPAMS AND ELECTRICAL NOTES I PHONE: (914) 725-3442
I
APPLICANT: AT&T WIRELESS SERVICES, INC.
903006201 E-2 ELECTRICAL DETAILS ANIS NOTES 0 '”` 15 EASE MIDLAND AVENUE
903 006 201 E-3 TELCO/ELEC/GROUNDING PLANS NO-�`�SAND DETAILS
SAF PARAMUS, NJ 07652
Y
Id, IIF ' A — 11 .F�
�y �'„ II LATITUDE: 41' 15' 40"
903 006 201 E-4 ENLARGED GROUNDING DETAILS LIGHTING/ELECTRIC PLAN, AND JI _ ;Y`� LONGITUDE: 72 00' 52"r
;I ELEVATION: 49'-0" AMSL*
903 006 201 E-5 ANTENNA CABLING SCHEMATIC AND DETAILS I socs� ISia allll
n
• .I JURISDICTION: TOWN Or SOUTHOLD
.�. � ;�� TAX I.D. NUMBER: SECTION: 9 BLK: 7 LOT: 1 1 . 1
SI � 1�IIOCAT�O � tl� _ ZONING DISTRICT: R-80
I i.e)I I p„F' II
II .I.IIII°1�I�Il�lll�ll�lliltllll, tv �� p1QI(� I�IIiWlll�l�l Ilili�lll�'w�Ir���od�'9II�ul�lllll�lllm11111 CURRENT USE: CHURCH
II II �1;1 11 1V
PROPOSED USE: CHURCH B
DPY ' li ,, " ti a FI I ;II 1 IIII '1 ill
Ill
' c �
,/' �'• AYE .� ` 1 ' � ' I .,�, *THE REFERENCED AMSL INFORMATION SHOWN HEREIN HAS BEEN OBTAINED UTILIZING 3—D
�I,I�II141, ';I71'llv ' 111r'I h TOPOQUADS TOPOGRAPHIC MAPPING SOFTWARE BY "DELORME ACTUAL ELEVATIONS MAY VARY
ACCORDING TO POINTS OF REFERENCE.
V \\e• W
1
TN
1.
�I�+6ry1aIII ' IIu II I" '
�1,,11;!�VII= TT
y� ai
SITE QUALIFICATION PARTICIPANTS
ifilllllV III I11'III�I'
�r/ ;l NAME COMPANY NUMBER
�s = i A/E NEIL A. MACDONALD WILLIAM F. COLLINS, AIA ARCHITECTS, LLP (631 ) 689-8450
t1 -S�E471l pp•_Gr } —
{/ _ I SAC PAUL PECKENS BECHTEL TELECOMMUNICATIONS (201 ) 294-6717
�s
RF SERHAD GUVEN BECHTEL TELECOMMUNICATIONS (201 ) 755-4297
Ishersisland CON GIL VERONESI BECHTEL TELECOMMUNICATIONS (412) 680-0922
l , A
LANDLORD N/A N/A N/A
FC PROJECT NO
FISHERS ISLAND "— Q 07/09/03 ISSUED FOR CONSTRUCTION JM AF TT 'SID Agcy 2-4926 AT&T WIRELESS SERVICES
AT&T 06/0.5/03 ISSUED FOR CONSTRUCTION C AF R �`y O
WILLIAM F. COLLINS, AIP, 903 006 201 A
— Q 5/15/D] ISSUED FOR ZONING AG,JM AF TT TITLE SHEET
A R C H I T E C T S, L L ; ' 11; ;
ORIENTAL AVENUE Q ID/30/W ISSUED FOR REVIEW PL A u _
10.1 TECHNOLOGY DRIVE SETAUKET,NY11733AT&T WIRELESS SERVICES, INC. NO. DATE REVISIONS By CHK API p 02694A JOB NO. SITE NO. DRAWING NUMBER REV
FISHERS ISLAND, NY 1 1957 15 EAST MIDLAND AVENUE \TR
VOICE: 631.689-8450 FAX: 631.689-8459 PARAMUS, NJ 07652
SCALE: AS NOTED DESIGNED DRAWN: PL 24445 903O06201A T- 1 1
DFN=STV[160,021 .DWG 22 z 34 D SIZE
6 5 4 3 2 PSG—
:
EXISTING STUD WALL SEE SCHEDULE SEE SCHEDULE
EXISTING MASONRY WALL N N
NEW 2 HR. SHAFT WALL DOOR AND HARDWARE SCHEDULE OR AND HARDWARE SCHEDULE
HOLLOW METAL DOOR \` NEW 1 /2" GYPSUM
FRAME BOARD ON RESILIENT DOOR #1 : 3'-0" x 6'-8" x 1 3/4" 16 GAUGE 24^ DOOR #2: 3'-0" x 6'-8" x 1 3/4" 16 GAUGE
CHANNEL INSULATED METAL, 1 1 /2 HR. "B" INSULATED METAL WITH 24"x24° STORM
HOLLOW METAL DOOR AS \\ \ LABEL. PROVIDE UL RATED WIDE-ANGLE PROOF LOUVER W/ BIRD SCREEN. PAINT
SCHEDULED (FISHEYE) PEEPHOLE. PAINT SUMMIT SUMMIT GRAY.
THRESHOLD BELOW GRAY. FRAME: 3'-0" x 6'-8" 16 GAUGE HOLLOW
FRAME: 3'-0" x 6'-8" 16 GAUGE HOLLOW METAL 1 1 /2 HR. FPSC. CAULK WATER
nJAMB (HEAD SIMILAR) nJAMB (HEAD SIMILAR) w METAL 1 1 /2 HR. "B" LABEL. CAULK w N TIGHT AROUND EXTERIOR PERIMETER.
WATER TIGHT AROUND EXTERIOR
U J J PAINT SUMMIT GRAY.
PERIMETER. PAINT SUMMIT GRAY. HINGES: 1 1 /2 PAIR 4 1 /2"x4 1 /2"xSTD.
EXISTING STUD WALL ww HINGES: 1 1 /2 PAIR 4 1 /2"x4 1 /2"xSTD. o WEIGHT, BALL BEARING HINGES WITH
BEYOND u2„ & 2„ WEIGHT, BALL BEARING HINGES WITH 2„ 2' CONCEALED SETSCREW TO LOCK IN
HOLLOW METAL FRAME -- CONCEALED SETSCREW TO LOCK IN HINGE PIN. STANLEY NO. FB8191 .
BEYOND w HINGE PIN. STANLEY NO. F1313191 . LLJ
HOLLOW METAL DOOR AS NEW VCT FLOORING 3 V) bi DOOR #2 SCHLAGE L-SERIES LOCK AND DEAD
DOOR #1 SCHLAGE L-SERIES LOCK AND DEAD LOCKSET: BOLT ASSEMBLY, MODEL# L94P.
SCHEDULED — 1 LOCKSET: BOLT ASSEMBLY, MODEL# L94P. 3
CLOSER: LCN 4010
SWEEP WITH RAIN DRIP CLOSER: LCN 4010 STOP: CANVAS OR RUBBER COVERED CHAIN
THRESHOLD SET IN STOP: STEEL BRUSHED CHROME FINISH STOP.
SEALANT RUBBER FLOOR STOP . WEATHER-
WEATHER- STRIP: VINYL BULB TYPE AT HEAD AND JAMBS.
THRESHOLD STRIP: CONTINUOUS SMOKE PROOF GASKETING. SILL
UTHRESHOLD U 2 4 PROT: BRUSH TYPE.
THRES-
HOLD: ALUMINUM THRESHOLD IMBEDDED IN
DOOR #1 DOOR #2DOOR #1 DOOR #2 SEALANT.
SCALE: 1 1/2"=1'-0" SCALE: 1 1/2"=1'-0"
SCALE: 3/4=1'-0=1'-0' SCALE. 3/4"=1'-0'
DOOR DETAILS
1 SCALE: AS NO
TED
ANTENNA
MFG: DECIBEL
PART NO. : 731DG65V1EXM
o —
1 MOUNTING BRACKET
MFG: DECIBEL
PART NO. : DB380 (INCLUDED)
i
7" 1 1
FRONT VIEW SIDE VIEW TOP VIEW
ANTENNA DETAIL
L SCALE. iT=1 -0
Q _ FC PROJECT NO
AT&T ��a�D A'-c 02-4926 AT&T WIRELESS SERVICES
FISHERS ISLAND �,5 °ER ���
903 006 201 A
WILLIAM F. COLLINS, AIA os/os/m ISSUED FOR CONSTRUCTION w AF Tr 'U ' � ARCHITECTURAL DETAILS
A R C H I T E C T S, L L P A 10/X1/02 ISSUED FOR REVIEW PL AF TT
ORIENTAL AVENUE
10-1 TECHNOLOGY DRIVE SETAUKET,NY 11733 AT&T WIRELESS SERVICES, INC. NO. DATE REVISIONS Rr CHH APP'D V y\ 026944 / JOB NO. SITE NO. DRAWING NUMBER REV
FISHERS ISLAND, NY 1 1957 15 EAST MIDLAND AVENUE F
VOICE: 631-689-8450 FAX: 631-689-8459 PARAMUS, NJ 07652 <- !"
SCALE: A9 NDTED DESIGNED DRAWN: PL 24445 903006201 A A-4 0
6 5 4 3 DFN=STV[160,02] DWG 22 k 34 SIZE
PSC=
INNOVATIVE TECHNOLOGY, INC . TO RADIO CABINET NOTES:
(NOKIA/ERICSSON) Tl SURGE SUPPRESSOR 1 . MOUNT S66M1 -50 BLOCK W/89B BRACKET IN TELCO
BOX OR ON TELCO BACKBOARD OR IN NEW 3R
TRANSIENT VOLTAGE SURGE SUPPRESSOR ATLANTIC SCIENTIFIC No. 4WH O O
90700 (SEE NOTE 2) ENCLOSURE AT OUTDOOR SITES.
PORT MARKED::: 2. WIRE TO PROVIDE CONTINUITY WHEN CIRCUIT IS NORMAL."PROTECTED" DIN RAIL ATLANTIC 3. INSTALL BRIDGING CLIPS (SIEMON-SA- 1 -25 OR 2 o NA
MODEL DESCRIPTION PEAK AMPS SCIENTIFIC 21607 EQUIVALENT) AS REQUIRED. 3 0
RJ48 (TYP) 4. TURN BACK AND STORE UNUSED CONDUCTORS.PTX080-3Y101 NSS 80,000 4 o JNA
SURGE SUPPRESSOR THREE PHASE PLASTIC WHT GRN o 5 o D
SURGE SUPPRESSOR NOTCH NOTES: "ELECTRICAL CONTRACTOR SHALL ALLOW FOR ONE GRN WHT o 6 0 ) NA
1 scALE: N.T.S. ADDITIONAL TRIP TO RE-TERMINATE 66 PUNCHDOWN BLOCK WHT BRN
WIRING ONCE REVISED DETAIL# 1022 IS ISSUED BY BRN WHT o 8 o NA
BECHTEL."
PANEL "PI " S LT
sT WHT o 110 0 , NA
1 NSS 3P30 GFI RECEPTACLE 1P15 2 LABEL }
RED BLU o 11 0
3 ♦ SMOKE DETECTOR 1P15 4 1 WHT/BLU m BLU RED o 12 0 NA
_ BLU/WHT
5 ♦ EXHAUST FAN 1P15 6 20 WHT/ORG vw0 RED ORG o 13 0
7 NOKIA #1 2P40 CORD REEL P15 8 2 ORG/WHT - ¢ ORG RED o 14 o J INTRUSION
PORT MARKED 21 RED GRN o 15 0
9 v TELCO RECEPTACLE 1P15 10 WHT/GRN z ED
"UNPROTECTED" 3 0 ¢ GRN RED — 16 — HIGH TEMP cn
11 NOKIA #2 2P40
INTERIOR ucHTs/Eb:T 1P1s 12 RJ48 TYP 6 AWG GRN/WHT 0 L)
( ) # 22 ED Of RED BRN o 17 0 Of
13 ♦ INTERIOR RECEPTACLES 1P15 14 BONDED TO MGB OR O WHT/BRN o X o g
4 BRN RED o 18 0 LOW TEMP ¢
NOTES: GROUNDED ENCLOSURE BRN/WHT ¢
15 NOKIA 3 2P40 MOTION SENSOR 1P15 16 N w o
# TO TELCO 23 p m w RED SLT o 19 Z
17 ♦ SPACE 18
1 . MOUNT DIN RAIL TO NIU 5 WHT/SLT m w = SLT RED 20 — SMOKE
TELCO BOARD SLT/WHT - V) a
19 SPACE SPACE 20 2. DIN RAIL HOLDS 1 -4 N °
00 24 m ¢ Lo BLK BLU o 21 o w
21 SPACE SPACE 22 UNITS o ° 6 RED/BLU 0 Of BLU BLK o 22 o J NSS FAIL wo
3. NSS MAY BE ORIENTED TO o BLU/RED 0 o
23 SPACE SPACE 24 SUIT SITE REQUIREMENTS. 0 25 w BLK ORG o 23 0 -
w o o RED/ORG bi ¢ 0 RECT 24V G
25 SPACE SPACE 26 > v ° 7 1- Y - ORG BLK o 24 o MAINS
[ w ° 0 26 ORG/RED oz d BLK GRN o 25 0
27 SPACE SPACE 28 Qz 0 0 ¢ 1
29 SPACE SPACE 30 01 T1 ESURGE SUPPRESSOR cz 0 RED/GRN � LJ o J RECT 24V
0 8 w w GRN BILK
o 26 o J CHARGER
° GRN/RED 0
D- 0 ° 27 LL BLK BRN o 27 0
NOTE: o X o 0 9 RED/BRN 0cn BRN BLK o 28 r— Jl FUSE DIST
1 . CONTRACTOR SHALL PROVIDE BRANCH CIRCUITS TO ALL EQUIPMENT SHOWN CDS DATACOM INC. ATLANTA CABLE SALES INC (ACS) 0 BRN/RED o
ON PANEL SCHEDULE AND FLOOR PLANS FOR A COMPLETE INSTALLATION. VENDOR Z I- 0 28 z BLK SLT w w o PANEL
o 29
214-340-9199 800-241 -9881 z In 0 RED/SLT I-- No 1 AIR COND
0 ¢ 0 10 SILT BLK o 30 J
PANEL SPECIFICATIONS OUTDOOR DOUBLED ENDED P# C00411484-XXX P# 010717-1 -XXX 0 0 SLT/RED 0 _o YEL BLU o 31 0
FAIL 0
120/208V, 3 PHASE, 4 WIRE INDOOR DOUBLED ENDED P# C00411467-XXX P# 010716-1 -XXX o 0 29 0 11 BLK/BLU I wJ BLU YEL o 32 0 PSAX
MAINS: 200A PANEL CIRCUIT BREAKER OUTDOOR SINGLE ENDED P# C00411483-XXX P# 010717-XXX z p ° o BLU BLK ¢ JJ
LL I— 30 / 1— � YEL ORG o 33 0
INDOOR SINGLE ENDED P# C00411450-XXX P# 010716-XXX ° ¢ w 1 TECH ON
ENCLOSURE: NEMA 3R, SURFACE, 20" WIDE CABINET MODEL# NQOD430L225CU r- v o ° 12 BLK/ORG Y o ORG YEL o 34 o J SITE
POLES: 30 XXX = LENGTH IN FEET o ORG/BLK 0 Li
z 31 o W YEL GRN o 35 0
PANEL SHALL BE 42K AIC OR BETTER AND HAVE BOLI ON BREAKERS AND J Z 0 0 BLK GRN On o o BATTERY
WELDED GROUND BAR KIT. COVER SHALL BE LOCKABLE WITH HINGED DOOR 23478 B WHT 00 0 13 / GRN YEL 36 ) ACTIVE
N DOOR. WHT BLU R m olr i ° 32 GRN/BLK
TX °STRAIGHT 0 0 37 0
2 THROUGH ° BLK/BRN
PANEL SCHEDULE 3 NC CABLE 14 BRN/BLK a o 0 3g o 0
ORG WHT T CONFIGURATION" 33 w
2 SCALE: N.T S. 5 WHT ORG R RX 15 BLK/SLT a- o 0 40 0 0
ELECTRICAL SYMBOLS ABBREVIATIONS 6 NC O 34 SLT/BLK 41 0 0
o 0
7 N 16 YEL/BLU c0 0 0 42 0 o B
® GROUND ROD WITH ACCESS AWG AMERICAN WIRE GAUGE 8 NC 35 BLU/YEL 10 0 0 43 0 0
RJ48C o 0
8 CHEMICAL GROUND ROD BCW BARE COPPER WIRE g PIN CONNECTOR PIN ASSIGNMENT 17 YEL/ORG 44 0 0
DWG DRAWING CONNECTOR 18" GROUND PIGTAIL ORG/YEL o 0 45 0 0
® GROUND ROD TS CABINET ONLY BY BTS VENDOR) CDS DATACOM P/N 36 YEL/GRN o 0 46 0 0
0-1 DISCONNECT SWITCH EMT ELECTRICAL METALLIC TUBING (GND @ BC03610075-OOXX 18 0
GEN GENERATOR NOTES: (SEE NOTES 1 ,2,3) 37 GRN/YEL o 47 0 0
METER IGR INTERIOR GROUND RING (HALO) 1 . CABLE IS A NOKIA SPECIFIC DESIGN. WIRING IS UNIQUE AND SHALL BE USED FOR 19 YEL/BRN o 0 48 0 0
IMC INTERI IEDIATE METALLIC CONDUIT NOKIA ULTRASITE INSTALLATIONS ONLY. DRAIN o 0 49 0 0
CIRCUIT BREAKERMGB MASTER GROUND BAR o 0 50 0 0
2. SELECTED CABLE MUST BE FROM A VENDOR LISTED IN THE ABOVE TABLE
■ CADWELD TYPE CONNECTION PCS PERSONAL COMMUNICATION (NO SUBSTITUTIONS ARE PERMITTED) NOTES 0 O 0
SYSTEM 3. OBTAIN CABLE AND CONNECTOR ASSEMBLY FROM:
COMPRESSION TYPE CONNECTION PTS POWER TRANSFER SWITCH 3. DOUBLE ENDED CABLES ARE STANDARD. SINGLE ENDED OPTIONAL TO MEET UNIQUE CDS DATACOMM NOTE 3
SITE REQUIREMENTS.
GROUNDING WIRE PVC RIGID (SCH. 40) POLYVINYL SHAWN LONG
CHLORIDE CONDUIT 4. CABLE IS A STRAIGHT-THROUGH WITH IDENTICAL CONNECTOR PIN-OUT ON BOTH 972-424-7234 DIRECT
XefREPRESENTS DETAIL NUMBER RRGS WY RACEWAY GALVANIZED STEEL ENDS. 972-424-7620 FAX
�-REFERENCE SHEET NUMBER 2. CABLE AND 37-PIN CONNECTOR COME PREWIRED FROM
5. CABLE END WITH 18" GROUND PIGTAIL SHALL BE INSTALLED AT NOKIA BTS. CDS DATACOM.
TYP TYPICAL 3. 'OOXX' = CABLE LENGTH IN FEET.
ELECTRICAL SYMBOLS 6. ORDER LENGTH AND TYPE (OUTDOOR, INDOOR) AS APPROPRIATE FOR SITE S66M1 -50
REQUIREMENTS
AND ABBREVATIONS T1 CABLE AND CONNECTOR PIN-OUTI� ALARM CABLE 02 66 BLOCK ALARM ASSIGNMENTS A
O SCALE: N.T S. O1 SCALE: N.T.S. OZ SCALE: N.T.S.
_ Q FC PROJECT NO
FISHERS ISLAND �\yt�a o q�yh -4926 AT&T WIRELESS SERVICES
WILLIAM F. COLLINS, AI'A 903 006 201 A AT&T -�,
06/05/03 ISSUED FOR CONSTRUCTION W AF n -- "s ELECTRICAL DETAILS AND NOTES
ARCH I T E C T S, L I, P ORIENTAL AVENUE Q 10/30/02 ISSUED FOR REVIEW PL AF Tr n `
10.l TECHNOLOGY DRIVE SETAUKET,NY II'!33 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC. NO, DATE REVISIONS BY CHK APP'D `�PT� USR�/ ,ii JOB N0, SITE N0. DRAWING NUMBER IREV
VOICE: 631-689-8450 FAX: 631-681 15 EAST MIDLAND AVENUE -
PARAMus, NJ mss2 � 24445 903006201A E-2 0
SCALE: AS NOTED DESIGNED DRAWN: PL
2 DFN=STV[160,021 DWG 22 z 34 D SIZE
6 5 4 3 PSD-
NEW AT&T 200 AMP ELECTRIC
SUB-METER AT GRADE NOTE:
NEW ELECTRICAL CONDUIT ROUTED AT&T 2 0 AMP POWER PANEL E 1 #2 AWG STRANDED, INSULATED COPPER WIRE
MAY BE USED IN LIEU OF SOLID BCW FOR
FROM NEW AT&T SUB-METER TO NEW BONDING DEVICES FROM INSIDE SHELTER TO
t AT&T EQUIPMENT NEW AT&T 200 AMP "APPLETON" EMERGENCY THE EXTERIOR GROUND ROD .
E-1
EXISTING ELECTRIC UTILITY METER GENERATOR RECEPTACLE AT GRADE
AT GRADE EXISTING ELECTRICAL PANEL AND PLYWOOD
BACKBOARD E-1
GROUNDING NOTES:
NEW AT&T 200 AMP CAUTION!: AT ALL SITES THE CONTRACTOR MUST VERIFY THAT THE SYSTEM IS EFFECTIVELY GROUNDED AND MEETS THE NEC ARTICLE 250
DISCONNECT EXISTING SMOKE DETECTOR REQUIREMENTS AND ACCEPTABLE TO THE LOCAL INSPECTOR/AUTHORITY. NEC ARTICLE 250-84 SPECIFIES GROUNDING RESISTANCE OF 25 OHMS OR
LESS FOR THE GROUNDING SYSTEM. THE PROJECT REQUIREMENT IS FIVE (5) OHMS.
NEW TELCO COAXIAL CABLE ROUTED FROM
NEW LAND LINK PARABOLIC ANTENNA IN
I FuiuRE� — NOTE:
NEW AT&T EQUIPMENT iwcoMBal STEEPLE ABOVE TO NEW TELCO BOARD 1 . METALLIC OBJECTS LOCATED WITHIN 6'-0" OF GROUNDING HALO SHALL BE BONDED TO GROUNDING HALO
ROOM �----� �
I iNOKIA \ T
NOKIA
Ua2. PROVIDE STRAIN RELIEF AND PROTECTION FROM SHARP MATERIAL FOR INDIVIDUAL CABLES. PROVIDE #6 GROUND CONDUCTORS WITH TWO-HOLE
IBI�Ne%
CONNECTORS TO CABLE RACK SECTIONS TOGETHER
NEW EXHAUST FAN NEW 4'x4'x 5/8" FIRE RESISTANT PLYWOOD F2. GROUND
ES:
�K BACKBOARD NUMBER OF GROUNDING RODS REQUIRED, REFER TO AT&T WIRELESS SERVICES, INC. TECHNICAL SPECIFICATIONS FOR FACILITY GROUNDING.
ON6� WIRES SHALL BE ROUTED INTO THE EQUIPMENT ROOM FOR CONNECTION TO THE FOLLOWING:
BOND GROUND WIRE TO INTERIOR GROUND RING HALO AT A MINIMUM OF FOUR PLACES AND LOCATE CONNECTIONS ON OPPOSITE SIDES OF
THRIFT EQUIPMENT ROOM.
STORE - BOND GROUND WIRE TO MASTER GROUND BAR FOR INTERIOR EQUIPMENT SPECIFICATION FOR FACILITY GROUNDING, THE NEC AND LOCAL CODE
U✓ d REQUIREMENTS. ,
EXISTING STAIR FROM - BOND GROUND WIRE TO AC POWER SERVICES AND SURGE ARRESTOR IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR FACILITY
BASEMENT GROUNDING C
3. #2 AWG STRANDED, INSULATED COPPER WIRE MAY BE USED IN LIEU OF SOLID BCW FOR BONDING DEVICES FROM INSIDE EQUIPMENT ROOM TO THE
EXTERIOR GROUND RODS.
FOR ELECTRICAL AND GROUNDING
SYMBOLS AND ABBREVIATIONS SEE
DETAIL 500 SHEET E-2
tN 503 NEW GROUND ROD
4
ORIENTAL AVENUE CADWELD CONNECTION, (TYP) 514
TELCO/ELEC PLAN o
e NEW THROUGH WALL EXHAUST FAN TO
@ BASEMENT LEVEL �I)TE: ° z' 4' s' REPLACE EXISTING WINDOW o : FUTURE
`\
1 SCALE: 1 4" = F THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH z 1-___ �
1/4"—i,_ol. p iRK-EI _
LTRA
�ISITD
LCABINEi� G
— #2 AWG STRANDED INSULATED (INSULATION
INSPECTION WELL/W COPPER TO BE UV RESISTANT) OR BARE, SOLID, B
RU GROUND AND TEST LOOP
TINNED COPPER WIRE, TYP. 2 PER
TB 503 CABINET
NC TVSS PANE
c L -4 �, , G
FOR SURGE SUPPRESSOR
N '
S
No z ALARM, CONNECT TO COMMON NC
, eL
AND NORMALLY CLOSED c OaA
GROUND WIRE ROUTED FROM INTERIOR C,
TERMINAL BLOCKS. NORMALLY _q GROUND RING HALO TO EXTERIOR GROUND ME
UTILITY POWER FAIL BIN,7 NEW INTERIOR GROUND RING
CLOSED IN NORMAL POWER
CLOSED CONTACTS WILL BE No ROD HALO, (HALO BY SHELTER MANUF.)
FOR UTILITY POWER ALARM, CONNECT
TO COMMON AND NORMALLY CLOSED CONDITIONS. CONTACTS WILL 504 MASTER GROUND BAR
OPEN IF TVSS PANEL FAILS.
TERMINAL BLOCKS. NORMALLY CLOSED
0_
CONTACTS WILL BE CLOSED IN NORMAL TB �
POWER CONDITIONS, CONTACTS WILL 5
OPEN IF UTILITY POWER FAIL. NOTE: TB LOCATED WITHIN PANEL "P1 " 6 EXISTING STAIR FROM BASEMENT
UTILITY POWER FAIL
MANUF: POTTER & BRUMFIELD
MODEL:# K10P- 11A15- 120 ZN
AND BASE 27E487
0' 4' 8' 16'
,UTILITY POWER FAIL TVSS FAIL �(q)UIPMENT GROUNDING PLAN NOTE: A
�+ scAEE: N.T.s. O SCA E: NT.s. 2t 4 = t -o' IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH
FC PROJECT NO
FISHERS ISLAND AT&T , NT/M/R3 ISSUED FOR CONSTRUCTION JM AF ❑ " . ;;
/y ,.E�` � 4826 AT&T WIRELESS SERVICES
WILLIAM F. COLLINS, AIA 903 006 201 A QO 06/ovo3 ISSUED FOR CONSTRUCTION OJ AF n
A R C H I T E C T S, LLP QS 5/15/03 ISSUED FOR ZONING gc,JM aF n H'� ' �''^ TELCO/ELEC/GROUNDING
ORIENTAL AVENUE a 6 PLANS, NOTES AND DETAILS
10-1 TECHNOLOGY DRIVE SETAUKET,NY11733 Q tG/3G/Gz ISSUED FOR REVIEW PL AF n .I' s : 1�; v ),
VOICE: 631-689-8450 FAX: 631-689-8459 FISHERS ISLAND, NY 11957 AT&T WIRELESS SERVICES, INC.
15 EAST MIDLAND AVENUE N DDATE REVISIONS BY CHK APP'D `•fpr 028994 ��,j; JOB N0. SITE NO. DRAWING NUMBER R
EV
PARAMUS, NJ 07652 '�• (7p l,i •I „�
SCALE: AS NOTED DESIGNED PRAWN; PL 24445 903006201A E-3
6 4 3 DEN—SN[16D.02] DWG _Mx 34 7-SIZE
PSC-
z \
REMOVE EXISTING SMOKE
P1 - 14
DETECTOR COPPER WIRE TEST LOOP GRADE
�
FUTURE 1 -8 NEW POWER PANEL "P1 " EZ PRECAST CONCRETE INSPECTION
"COMA EX HAND HOLE ASSEMBLY WITH N
FUTURE NEW CORD REEL CAST IRON FLANGE AND COVER
NOKIA
HSE F2 WITH WORD 'GROUND' CAST _z
P1 - 10 INTO COVER. CADWELD
P1 -6 P1 -4 GRADE
NEW SMOKE DETECTOR, NEW 4' D TEL 8" THICK -"- D
PLYWOOD TELCO BOARD —
GRAINGER OR EQUAL F CADWELD CABLE —I —�
MODEL# 3KN55/57 ElW TO ROD. _ �_ #2 AWG BCW
El - � NEW MOTION SENSOR SOLID, TINNED
' 4 — —
P1 - 11 , Ex CLEAN SAND GROUND
P1 - 11 , 13I ' P1 -12 NEW EMERGENCY LIGHT FILL
P1 - 15,17
THERMOSTAT
COPPER WIRE GROUND ROD
NEW EXIT SIGN, TYP. GROUND RING n COPPER CLAD
STEEL 5/8"o
x10'-O" LONG
EXISTING STAIR FROM
BAS EM N ET
GROUND ROD COPPER
CLAD STEEL 3/4" X
BASEMENT PLAN 10'-0" LONG.
LIGHTING SCHEDULE c
SYM. MANUFACTURER / MODEL # TYPE FIXTURE LAMP NO. LAMPS MOUNTING HEIGHT REMARKS
WATTAGE TYPE WATTS DETAIL @ GROUND TEST WELL DETAIL @ GROUND ROD
F2 LEGION CAT. # 4304-232-ACP-ESB/EBO -BA FLUOR. 62 F032-TS 2-32 SURFACE/ STEM SURFACE/STEM MOUNTED NARROW WRAP 2 SCALE: N.T.s. 0 scALe N.T.S.
EX ATLITE CAT # XLN 18SR2U-BA LED. 2 LED 1 -2 WALL/ CEILING EMERGENCY EXIT SIGN, SHADING INDICATES
FACES, ARROW INDICATES DIRECTION
EM ATLITE CAT # 12ACNY2-BA INCAND. 36 12V PAR36 2- 12 WALL/ CEILING 2 HEAD EMERGENCY UNIT X
ST AWG TO GROUND BAR ANTENNA CABLE (D 11
tN STRANDED �
INSULATED
TWO HOLE LONG
ENLARGED LIGHTING BARREL LUG TELCO OR POWER CABLES
WEATHERPROOFING KIT
AND ELECTRIC PLAN NOTE: 2' 4' METALLIC (SEE NOTE 3)
1 IF THIS SHEET IS 11 " X 17", REFER TO ADJACENT GRAPHIC SCALE. NORTH CONDUIT
SCALE: �/a =� -o BURNDY TYPE GAR-TC GROUND CABLE GROUND KIT
17a�,=1�_U��
CONNECTOR (CAT# GAR3903TC)
#6 AWG STRANDED COPPER GROUND
4 � 1 METALLIC CONDUIT
CABLE POWER OR WIRE (GROUND ED TO GROUND BAR),
#6 AWG FROM ANTENNA (SEE NOTE 1 & 2) B
CABLE GROUND KIT #6 AWG STRANDED
0 7/16„ 374 0 0 0 INSULATED GROUND CABLE. CONNECTION OF CABLE GROUND
STRIP INSULATION IN
2 0 0 0 0 0 0 METALLIC AREA OF CADWELD KIT TO ANTENNA CABLE
0 0 0 0 0 0 CONDUIT
3 0o ° 0 o CADWELD OR BOND 6
08 GROUNDING # NOTES:
0 0 GROUND WIRE TO SAME 1 , DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT
i o E-a BUSHING GROUND BAR TO WHICH
1 GROUND CABLE IS ATTACHED, GROUND WIRE DOWN TO GROUND BAR.
�00� C
00 �OO p c - LEGEND METALLIC CONDUIT WITH 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR
GROUND WIRE RECOMMENDED BY CABLE MANUFACTURER.
Op 1 . COPPER GROUND BAR, 1 /4" X 4" X 20", NEWTON INSTRUMENT CO. CAT.
NO, B-6142, HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK
TWO HOI E LUG, TO 2. INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061 -4 SHALL NOT BE USED.
BE USESWITH 3. 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT NO. 3015-8
#2 AWG BCW TO
BUILDING OR GROUND 4. WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056
RING/HA .O 5. 5/8- 11 X 1 " H.H.C.S. BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012- 1
Q„ GROUND WIRE TO GROUND ROD AGROUND BAR DETAIL CONDUIT BONDING DETAIL i DETAIL @ CABLE GROUNDING KIT A
VV SCALE: N.T.S. V SCALE: N.T.S. <0 y" SCALE: N T.S. ■ v SCALE: N T.S
-� Q c PROJECT No AT&T WIRELESS SERVICES
�ae�,i
FISHERS ISLAND = AT&T /� � DEp ,\, 2-4x26
903 006 201 A _ /1 QC W/�3/0] ISSUED FOR CONS RUCTION M AF T k
WILLIAM F. COLLINS, AIA — ENLARGED LIGHTING/ELECTRIC
0 Ofi/DS/O] ISSUED FOR CONSTRUCTION GJ AF TT _ - ' S
ARCHITECTS, LLP � Q : 4a * PLAN AND GROUNDING DETAILS
ORIENTAL AVENUE ,�L 10/30/02 ISSUED FOR REVIEW PL AF 7F
1a1 TECHNOLOGY DRIVE SETAUKET,rn11733 AT&T WIRELESS SERVICES, INC. �`�0 026
FISHERS ISLAND, NY 1 1957 NO, DATE REVISIONS By CHK APP'D n JOB N0. SITE NO, DRAWING NUMBER REV
VOICE: 631-689-8450 FAX: 631-689-8459 15 EAST MIDLAND AVENUE \F
PARAMUS, NJ 07652 OF NF�T�.
SCALE: AS NOTED DESIGNED DRAWN: PL - 24445 903006201A E-4 1
DFN=SN[160,021 .DWG
6 5 4 3 2 22 x 34 D SIZE
7' t
PSC=
900 TX/RX 1900 TX/RX
NOTES:
1 . ALL MATERIAL ON THE TABLE BELOW SHALL CELL SITE INSTALLATION NOTES:
BE PROCURED BY BECHTEL. THE FOLLOWING INSTALLATION NOTES HAVE BEEN COMPILED FROM THE I . ALL ANTENNA COAXIAL CABLES AND JUMPERS SHALL BE INSTALLED
2. THE CONTRACTOR SHALL NOT EXCEED THE EXISTING PROJECT DOCUMENTS (I.E. PROJECT SPECIFICATIONS, EQUIPMENT WITHOUT LOOPS AND/OR PIGTAILS.
1 CABLE LENGTHS SHOWN ON THE DRAWING VENDOR DOCUMENTS, ETC.) FOR USE. THESE NOTES SHALL BE UTILIZED
WITHOUT RF ENGINEERING APPROVAL. FOR THE CONSTRUCTION OF THE CELL SITES TO ENSURE COMPLIANCE
QUADPOLE SECTOR 3. CABLE LENGTHS LISTED ARE APPROXIMATIONS WITH THE PROJECT DESIGN AND SPECIFICATION REQUIREMENTS. 2. ANTENNA COAXIAL CABLE GROUND KITS SHALL NOT BE INSTALLED ON
THE JUMPER BETWEEN THE ANTENNA AND MAIN LINE CABLE.
ANTENNA, TYP. BASED ON THESE PLANS AND ARE NOT A. GROUNDING:
LAND LINK PARABOLIC INTENDED TO BE USED FOR ORDERING CABLE.
7/16" D N TYPE FEMALE DISH ANTENNA ALL CABLE LENGTHS MUST BE V.I.F. ALL METAL CONDUIT FOR GROUNDING DOWN CONDUCTORS SHALL BE 3. ANTENNA COAXIAL CABLE GROUND KITS SHALL BE INSTALLED AS CLOSE
CONNECTOR (ANTENNA) BONDED TO THE GROUND SYSTEM AT BOTH ENDS. TO THE CONNECTOR AS POSSIBLE AT EACH ANTENNA. IF THIS IS NOT D
4. COLOR CODE ALL MAIN 2. GROUNDING CONDUCTORS SHALL BE CONNECTED TO THE MAIN WATER FEASIBLE THE GROUND KIT SHALL BE INSTALLED IMMEDIATELY AFTER THE
5
TOP JUMPER CABLE CABLES AT TWO LOCATIONS: PIPE USING A BURNDY TYPE GAR-TC CLAMP.
2A (IF REQUIRED) NEAR ANTENNA,
BEND ON THE FIRST STRAIGHT RUN OF CABLE. THE GROUND KIT SHALL
NEAR EQUIPMENT 3. KOPR-SHIELD ANTI-OXIDATION COMPOUND SHALL BE USED ON ALL BE INSTALLED ON STRAIGHT SECTION OF CABLE ONLY AND NOT ON
GROUNDING CONNECTIONS. BENDS.
2 -////-MAIN COAXIAL CABLE 5. ANTENNAS SHALL BE PROCURED AND 4- ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE 4. ANTENNA COAXIAL CABLE SHALL BE INSTALLED TO COMPLY WITH THE
INSTALLED WITH DOWNTILT BRACKETS AND CADWELD PROCESS.
2AHEAVY DUTY CLAMPS SUPPLIED BY ANTENNAMANUFACTURER'S MINIMUM BEND RADIUS SPECIFIED IN THE FOLLOWING
MAIN COAXIAL CABLE MANUFACTURER UNLESS OTHERWISE NOTED. 5- ALL CADWELDS SHALL BE INSTALLED USING THE PROPER CONNECTION / TABLE. THE CONTRACTOR SHALL INSTALL RACEWAY FOR COAXIAL CABLE
4 GROUNDING KIT < 13A MOLD AND MATERIALS FOR THE PARTICULAR CONNECTION OR USING THE PROPER FITTINGS NECESSARY TO ENSURE THAT THE MINIMUM
E-a 6. TOP AND BOTTOM JUMPERS SHALL BE N AND/
SUPPLIED AND INSTALLED BY THE EQUIPMENT APPLICATION. BEND RADIUS REQUIREMENTS ARE MET. PROVIDE A DRIP LOOP AT
3 GRouIvelNG KIT E134 MANUFACTURER. TEE CONNECTION SWEEP CONNECTION POST CONNECTION ANTENNA.
GROUND BAR (NEAR sos
ANTENNAS), SEE DETAIL @ 7. CONTRACTOR SHALL VERIFY ANTENNA TYPE ANTENNA POST
GROUND BAR sos AND AZIMUTH WITH CONSTRUCTION MANAGER COAXIAL CABLE MINIMUM BEND RADIUS
(NEAR ANTENNAS) E a PRIOR TO STARTING CONSTRUCTION. CADWELD
CADWELD MINIMUM BEND MINIMUM BEND
8. CONTRACTOR SHALL PROVIDE AN CABLE SIZE RADIUS IN
/' CADWELD #2 AWG MANUF. CABLE TYPE RADIUS IN
GROUND BAR 22 INDEPENDENT TESTING AGENCY TO PERFORM #2 #2 BCW (DIAMETER) TRAY 4" OR 6" CONDUIT
(AT EQUID.) E_4 COAXIAL SWEEP TEST AND REPORT, AND AWG AWG
SEE DETAIL PROVIDE THE NECESSARY QUALIFIED BCW BCW ANDREWS LDF5-50A 7/8" 10" CONTACT COAX MANUF.
#2 AWG INSULATED PERSONNEL AND EQUIPMENT NEEDED TO
#2 AWG INSULATED GROUND WIRE ASSIST IN ANY REPAIRS AND WEATHER 6. ALL BOLTED GROUNDING CONNECTIONS SHALL BE INSTALLED WITH A LOCK ANDREWS LDF6-50 1 1 /4" 15" CONTACT COAX MANUF.
GROUND WIRE PROOFING. CONTRACTOR IS TO PROVIDE WASHER UNDER THE NUT. HARDWARE FOR BOLTED CONNECTIONS SHALL ANDREWS LDF7-50A 1 58" 20" CONTACT COAX MANUF.
_ _ BECHTEL WITH A MINIMUM OF 48 HOURS BE MINIMUM OF 3/8" DIAMETER AND SHALL BE STAINLESS STEEL. /
COPPER PLATE NOTICE PRIOR TO TIME OF SWEEP TEST AND C
EQUIPMEIJT FURNISH RESULTS WITHIN 48 HOURS OF
GROUND BAR COMPLETION. ALL SWEEP TESTING TO BE 7. OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISHING A "CHOKE" POINT.
BASEMENT (AT EQUIP.) E°y DONE IN ACCORDANCE WITH SPECIFICATION GROUNDING WIRE SHALL NOT BE INSTALLED OR ROUTED THROUGH HOLES
EQUIPMENT SECTION 24. IN ANY METAL
4 4 9. ALL INDICATIONS OF NORTH ARE FOR 5. ALL ANTENNA COAXIAL CABLES SHALL BE MARKED IN ACCORDANCE WITH
REFERENCE ONLY. CONTRACTOR VERIFY
SE
6 IN FIELD TRUE NORTH PRIOR TO SECTOR THE REQUIREMENTS IN BECHTEL ENGINEERING STANDARDS DOCUMENT
5 BOTTOM JUMPER CABLE
5 ANTENNA INSTALLATION. #24445-801 -3DS-GET-0002-001
.
6. THE CONTRACTOR SHALL ORIENT THE COAXIAL CABLES ON THE ICE
BRIDGE TO MATCH WITH THE ORIENTATION OF THE COAX ENTRY HATCH
LAND LINK ALPHA SECTOR BETA SECTOR GAMMA SECTOR TOTAL I PLATE ON THE SHELTER.
ITEM ITEM DESCRIPTION AZIMUTH 36. 15 AZIMUTH 70' AZIMUTH 240' AZIMUTH 310' QUANTITY
N0. TX/RX TX/RX TX/RX TX/RX TX/RX TX/RX (SEE NOTE 1 #2 AWG BCW 7. ONLY ANDREWS GROUNDING KITS SHALL BE USED ON ANDREWS CABLE.
ANTENNA
DEPICTS CHOKE POINT THE FOLLOWING IS A LIST OF PART NUMBERS FOR GROUNDING KITS.
1 ANDREW DECIBEL DECIBEL DECIBEL DECIBEL DECIBEL (NOT ACCEPTABLE)
(SEE NOTE 5) P3F-52-N7A 731DG65V1EXM 731DG65V1EXM 731DG65V1EXM 731DG65V1EXM 731DG65V1EXM 5+ 1
AS-BUILT SERIAL # 8. FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUNDING
MECHANICAL CONDUCTOR SHALL NOT BE USED. CLIPS OF THE FOLLOWING MATERIALS NOMINAL ANDREWS
DOWNTILT UPTILT 0.06' 0' 0' 0' 0' 0' AND TYPES MAY BE USED TO FASTEN AND SUPPORT GROUNDING CABLE SIZE ANDREWS STANDARD
ANTENNA JUMPER CONDUCTORS. (DIAMETER) CABLE TYPE GROUND KIT
2 (ANDREW) N/A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-5DA
(LENGTH) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /�2" (6 FEET) 1 /2" (6 FEET) 60 FT PLASTIC CLIPS 7/8" LDF5-50A SGL5- 10B4
ATTACHED MALE DIN INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED 1 1 /4" LDF6-50 SGL6- 10B4
2A CONNECTOR (1 ) LSPNM-RPC W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2 W/ITEM #2 1 5/8" LDF7-50A SGL7- 10B4 B
(ANDREW)
AIN COAX ° METAL CLIPS WHICH DO NOT COMPLETELY SURROUND THE
3 (LENGTH) (1 ) 5/8"0 (65- 1 (2) %" ((65') (2) %"0 (72') (2) �/8"0 (72') (2' /a"d (85') (2) 7/8"0 (85') 763 FT 7/8"0) GROUNDING CONDUCTOR 8. SNAP-IN HANGERS USED FOR 7 8 ANDREWS CABLE SHALL BE ANDREWS
(ANDREW) LDF4.5-50 LDF5-50A LDF5-50A LDF5-50A LDF5-50A LDF5-50A 65 FT (5/8"0 SNAP-IN HANGERS. SNAP-IN HANGERS USED FOR 1 1 /4" AND 1 5/8"
UNATTACHED MA 1 ) DIN F MALEANDREWS CABLE MAY BE ANDREWS SNAP-IN HANGERS OR EQUIVALENT
4 DIN CONNECTOR Q) EQ. L5PDF-RPC L5PDF-RPC L5PDF-RPC L5PDF-RPC L5PDF-RPC 20 HANGERS FROM ANOTHER VENDOR.
(ANDREW) -4.5RDF-RCI
UNATTACHED MALE (2) N MALE
5 DIN CONNECTOR ANT L4PDM-RPC L4PDM-RPC L4PDM-RPC L.4PDM-RPC L4PDM-RPC 20 9. HOISTING GRIPS USED FOR 7/8", 1 1 /4" AND 1 5/8" ANDREWS CABLE
(ANDREW) L4.5PNM-RC 9. STANDARD GROUND BARS SHALL BE FURNISHED AND INSTALLED. THEY MAY BE ANDREWS OR EQUIVALENT HOISTING GRIPS FROM ANOTHER
ANTENNA JUMPER SHALL NOT BE FABRICATED OR MODIFIED IN THE FIELD. VENDOR. FOR 1 5/8" COAXIAL CABLE, A STAINLESS STEEL HOSE CLAMP
6 (ANDREW) LDF4-50A C(2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A (2) LDF4-50A 60 FT MUST BE INSTALLED WITH THE HOISTING GRIP.
(LENGTH) 1 /2" (6 FEET) 2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 1 /2" (6 FEET) 10. ALL GROUND WIRES SHALL BE INSTALLED WITHOUT LOOPS (PIGTAILS) AND
SHARP BEND RADIUS.
7 ID TAG ALPHA 2 ALPHA 1 BETA 1 BETA 2 GAMMA 1 GAMMA 2 C. MANUFACTURED MATERIAL:
8 COLOR CODE 3 GREEN G EEN
TW ONE BLUE TWO BLUE ONE WHITE TWO WHITE B. ANTENNA COAXIAL CABLES �WAVEGUIDE)
TWO GREEN 1 . WHEN SPECIFIC MANUFACTURER'S ITEMS ARE SPECIFIED, THEY MAY BE
1 NOTE: THE RF TRANSMISSION LINE INSTALLED BETWEEN THE RADIO REPLACED BY SIMILAR, EQUIVALENT ITEMS WITH PRIOR ENGINEERING
CABINET, FURNISHED BY RBS EQUIPMENT SUPPLIER, AND THE ANTENNA APPROVAL.
CONSISTS OF A COAXIAL CABLE, SOMETIMES REFERRED TO AS A
/ANTENNA SCHEDULE WAVEGUIDE. A
FC PROJECT NO
Q 07/09/03 ISSUED FOR CONSTRUCTION JN AT TT ;\ -4926 AT&T WIRELESS SERVICES
FISHERS ISLAND AT&T DER411
�--� Qp 06/05/09 ISSUED FOR CONSTRUCTION
WILLIAM F. COLLINS, AIA 903 006 201 A - f ' ANTENNA CABLING SCHEMATIC
A R C H I T E C T S, LLP s/1s/m IssueD FOR zonlNc Ac,JN AF Tr
ORIENTAL AVENUE J r AND DETAILS
QA 10/30/01 ISSUED FOR REVIEW PL AF TI � _
10.1 TEC14NOLOGY DRIVE SE'CAUKET,NY 11733 AT&T WIRELESS SERVICES, INC.
VOICE: 631-689-8450 FAX: 631-689-8459 FISHERS ISLAND, NY 11957 15 EAST MIDLAND AVENUE NO. DATE REVISIONS BY CHH APP'D \e ly JOB NO. SITE N0, DRAWING NUMBER REV
PARAMUS, NJ 07652 OF 24445 903006201 A E-5 1
SCALE: AS NOTED DESIGNED DRAWN: PL
6 5 4 3
2 DFN=STV[160,02] DWG 22 x N SIZE
PSC=