Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51018-Z
�oy�aue S�(ITyo�o Town of Southold * P.O. Box 1179 io 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45750 Date: 11/09/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3600 Pequash Ave Cutchogue,NY 11935 Sec/Block/Lot: 103.4 4-2 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 06/18/2024 Pursuant to which Building Permit No. 51018 and dated: 08/01/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to: Robert Martinez,Kathleen Martinez Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51018 11/04/2024 PLUMBERS CERTIFICATION: Au o zed ignature o�S�fFQI,rcD TOWN OF SOUTHOLD BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51018 -Date: 8/1/2024 Permission is hereby granted to: VNP Properties Inc 4248 Grand Ave Mattituck, NY 11952 To: Install-roof mount solar to existing single family dwelling as applied.for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 3600 Peguash Ave, Cutchogue SCTM #473889 Sec/Block/Lot# 103.-14-2 Pursuant to application dated 6/18/2024 and approved by the Building Inspector. To expire on 113112026. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-RESIDENTIAL $100.00 Total: $325.00 Building Inspector �o��oF so�ryol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Southold,NY 1 1 97 1-0959 .oly� � �o Jamesh _southoldtownny.gov 4UNT`I, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: VNP Properties Address: 3600 Pequash Avenue city,Cutchouge st: New York zip: 11935 Building Permit#: 51018 Section: 103 Block: 14 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: Element Energy LLC. Electrician: Jaime Minnick license No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 60a Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 14.875kw roof mounted pv solar energy system with 35 panels[JKM425N-54HL4-B] 35 micro inverters[IQ8MC-72-M-US] 1 fused disconnect, 1 enphase combiner panel Notes: SOLAR ENERGY SYSTEM Inspector Signature: Date: November 4, 2024 3600 pequash ave OE 50UTyolo * TOWN OF SOUTHOLD BUILDING DEPT. ,00rm,��'' 631-765-1802 oc $ INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND_ [ ] I LATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL `d4-V✓ [ ] FIREPLACE & CHIMNEY [ .] 'FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ ] -FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ . ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: l DATE o INSPECTOR �OF SO(/l �- o� �� 4 �� # # SOU O TOWN F THOLD BUIL G DEPT. O 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] _FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION, [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [A ELECTRICAL (FINAL) [ ] 'CODE VIOLATION, [ ] PRE C/O ' [ ]. RENTAL REMARKS: fcit f DATE I �' `t "� INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION (IST) 4t ------------------------------------- - ,- CIO FOUNDATION (2ND) ROUGH FRAMING& PLUMBING A INSULATION PER N. Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS p fc, 0 z m ----------- i f� ocr�oG,a TOWN OF SO UTHO LD—BUILDING DEPARTMENT av "Town Hall Annex 54375 !Main Road P. ®. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https:Alwww.southoldtow,nnyaov I Date Received APPLICATION FOR BUILDING PERMIT -- 4 For Office Use Only v "A I 8 2 PERMIT NO. Building Inspector: JUN 1 02 Applications and forms must be filled out in their entirety.fncomplefe A applicatfons wfil not be accepted. Where the Appikant us not the owner,an Ownees Authorization Ionn(Page 21 shali be completed, Date: (o ig/a OWNER(5)OF PROPERTY.- Name: Re 6cr� MA-4-)ng SCTM# 1000- 1 vo - l Po r a•o ao Project Address: 3 Ce p p A- aril-) a P�C. Cl-fch o 0-J 193S Phone#: (� _ 2 d -7®Lf Ico 01 Mailing Address: 3(o Q 0 LA-4,$h AVt f n ��t CO�til(AOT FIEMN; l � Name: LD rrA i'n Mailing Address: -7 47 o SouAd, a M A'4 m 5'a' Phone#: 0 3 �70q I Email: pe CCN 11 43 o DESIGN PhiOFESSIRDNALONFC8l3MATIONN Name: Mailing Address: Phone#: Email: CbINT iACr®R INMRMAMONs Mailing Address: 14 ' m Phone#: (� 0 , '"� D 4 Email: -��` S �� b ❑New Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: ther I n5-ha..0 Sb l&v- P V 5�j s-1-r-kn $ Sg_�__I Will the lot be re-graded? ❑Yes;KNO Will excess fill be removed from premises? ❑Yes)2!No 1 i PROPERTY INFORMATION Existing use of property: Intended use of property: R" Zone or use district in which premises is situated: Are there any cove is aad restrictions with respect to this proper#ja. s Mo IF YES, PROVIDE A COPY. hec Box After-Reading:;The owner/contractor/design.professional is responsible.for all drainage and'.storm-:water issues as provided by Chapter 236 of the,Town Code.,aAPPUCATION IS HEREBY MADE to the Building:Department for the issuance of a:Building'Permit pursuant to the Building Zone Ordinance of the Town of+SOUtHoldj Suffolk,County,New York and other applicable laws,Ordinances or Regulations;for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,buildingcode,, housing code and regulations and to admit authorized Inspectors on premises and in building(s)fornecessary inspections.False statements made herein.are , punishable as a Class A•misdemeanor pursuant to Section 210A5 of the New York State Penal law. Application Submitted By(print name):Lorraine Di Penta ®Authorized Agent ❑Owner Signature of Applicant: � ) ' ®ate: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine ®iPenta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20 Notary Public LOUIS J ROMEO Notary Public,State of New York No.01 R06314813 PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County (Where the applicant is not the owner) Commission Expires November 17,20.; residing at 3� a Gt,v-C— E lt�r�,,� tc wL C.o rrAr� -`G[~�► 1Uq"�� ��4 do hereby authorize h-'-!"�1 y to apply on my behalf to 0 of So old Building Department for approval as described herein. Owner's Signature LOUIS J Rto OMEO U7' ' �/1� Notary Public,State of New York ll'' No.01 R06314813 Print Owner's Name Qualified in Suffolk County Commission Expires November 17,20—7-6 2 �StFFOt,�CO BUILDING DEPARTMENT§Tri4l 9hspktor TOWN HOLD o = Town Hall Annex - 5437 in R AF01 1179 o Southold, New k 1 V -0959 { '1'.jj01 �a0� Telephone (631) 765-18 - FAX (631),7e�P-'502 .J rogerrO-southoldtownny.4ov-- seand0-so a6Idtownny.aov .tov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: G l eM CA4 E r)er-, L-L- j Electrician's Name:-JojmL, M j-ny)1 eK License No.: 5 a G R _ H E Elec. email: �e,f-m i+'5 e, c a s �S, CD)YI Elec. Phone No: ( 3ts- )l .-)v1t)3 [9I request an email copy of Certificate of Compliance Elec. Address.: -7 4-7 o 6o vyi�-. avc, M b 41AC K-_ 6;a� JOB SITE INFORMATION (All Information Required) Name: �t� r rna.rt-1. Address: �(� (�O Ll S�j Cross Street: un Jqd Phone No.: (06 t .'a-g S 0 Lf Q Bldg.Permit #: email: 9f,,M4S Tax Map District: 1000 Section: fl 3 Block: N Lot: 2 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): sa la,f- PV Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES® NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ® NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Yoe workers'STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that came 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1 c.Federal Employer Identification Number of Insured Wont Location of Insured{t?nlynsqufred ifcaverage is speciRcallylimited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life tnsuranee Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"W SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01101/2023 to 12/31/2024 4. Policy provides the following benefits: ® A Both disability and paid family leave benefits. n B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of fhe employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andtor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By w4a,&f (Signature of insurance earriees authorized representative or NYS Licensed Insurance Agent ofthat insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 6200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If Box 4e,4C or 58 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance poricies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to Issue this form. DB.120.1 (,s-s,) IIIII�►���'�i�iir��ii�iiu�iiiiuiiilfl A`�R� CERTIFICATE OF LIABILITY INSURANCE OATE,M 71�D12,20, THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorseme"s). PRODUCER HCONTACT AM ROBERT S.FEDE INSURANCE AGENCY PHONE - FAX 23 GREEN STREET,SUITE 102 EMAIL Ems' AIC No: HUNTINGTON,NY 11743 ADDRESS:ROBERTS.FEDE INSURANCE wsu AFFORDING COVERAGE NAIC a INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER B.-STATE INSURANCE FUND 523930 Element Energy LLC . INSURER c c DBA ELEMENT'ENERGY SYSTEMS s�D. GENERAL STAR MANAGEMENT CO. 7470 SOUND AVENUE IN INSVRERE. MATTITUCK,NY 11952 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. tNSR TYPE OF INSURANCE POLICY EFF POLICY EXP LTR POLICY NUMBER MIDD M LIMITS COMMERCIAL GENERAL LIABILITY L1460036873 EACH OCCURRENCE s 3,000,000 A X X 7/142023 7/14/2024 CLAIMS-MADE ©OCCUR PREMISES owrrenea S 100,000 MED EXP I one person) 3 5000 X Contractual Lia 7NA3892038 7/19M22 7/19/2024 PERSONAL a ADV INJURY s 30000DO GEML AGGREGATE UMIT APPLIES PER: GENERAL AGGREGATE S 3,000,000 POLICY a PRO- a JECT LOG PRODUCTS-COMPlOPAGG S 3000000 OTHER: S AUTOMOBILE LIABILITY FMB tSINGLE LIMIT $ ANY AUTO BODILY INJURY(Par person) S AUTOSOWN ONLY SCHEDULED ( ) S AUTOSBODILY INJURY Per weident HIRED NON-0WNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY erodent S s UMBRELLA LIAB OCCUR EACH OCCURRENCE S EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED IL I RETENTIONS $ MIORKERS COMPENSATION 124494445 PER OTM- AND EMPLOYERS' YIN YIN AT ER RIP ANY PROPRIETOARTNE&EXECUTIVE 7/13/2023 7/13r2024 B OFFICERIMIEMBER EXCLUDED? x N I/► EL EACH ACCIDENT S 1 000000 (Mandatory In NMI EL DISEASE-EA EMPLOYEE S If yea,describe under DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT s NY State DBL DBL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS I VE RCLES(ACORD 101,Addttlenal Remarks Schedule,maybe affeebw if mare space Is regulred) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORLMO REPRESENTATIVE f0beftS. Fed& ©1988-2015 ACORD CORPORATION. All rights reserved. error'yc Tkn AP`nlan ..,a I.... .... ,,:aa....r..,. .1—„4r Arran NYSMF New York State Insurance Fund PO Box 66699,Albany,NY 12206 J nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 0 0 ^^°^^^ 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 0 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 369075 07/13/2023 TO 07113QG24 17111/2023 THIS IS TO CERTIFY THAT THE POUCYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDERS REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY.INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COM/CERTICERTVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU CE FUND T DIRECTOR,INSURANCE FUND UNDERWRITING i OCCUPANCY OR APPR001 D AS NOTED USE IS. UNLAWFUL oA •�• B.P.* 5/0/d' WITHOUT CERTIFICATE 3�7 •�5� BY OF OCCUPANCY NOTIFY BUILDING DEPARTMENTAT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED �nR POURED CONCRETE 2. y -FRAMING&PLUMBING 4. FINAL-CONSTRUCTION MUST t+OMPL.Y W BE COMPLETE FOR C.O. NE YORKW"' TCODES OF ALL CONSTRUCTION SHALL MEET THE STATE 8t AS FWtF OWN CODES 3EQUIREMENTS OF THE CODES OF NEW AND CONDITIONS OF `/ORK STATE. NOT RESPONSIBLE FOR TOWNzm `hSiGN OR CONSTRUCTON ERRORS SommomALaImaBOfia soummalums NyaD �UINOLDI�C a�cra><cN,�xsrecno� o � , RETAIN STORM WATER RUNOFF_ PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Page 1 bf 2 c Current 06/17/2024 Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Robert Martinez Residence Project Address: 3600 Pequash Avenue, Cutchogue, NY, 11935 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 of NEWA. y Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com V 106793 Signed on:06/17/2024 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 20 degrees and has a max beam span of 8.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 30 degrees and has a max beam span of 11.5 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 20 degrees and has a max beam span of 15.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com A FUSE SIZING M ELECTRICAL EQUIPMENT LIST OF NEW MAX.X. CONTINUOUS OUTPUT 1.33A @ 240V Eoe MAN/,p YOB 46.55 X 1.25 = 58.19AMPS 60A FUSES-OK S. NO. ITEMS DESCRIPTION QTY. Gj �O yC JINKO SOLAR Tk G 1 PV MODULE JKM425N-54HL4-B 35 ACCOUNT NUMBER -9623031300 1- z D w METER NUMBER-98298054 n L 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 35 Z 099128 MODULE 3 COMBINER ENPHASE IQCOMBINER C7R 1 A \ MANUFACTURER JINKO SOLAR 5/5C 1ONP��� 60A RATED D322NRB ASS SQUARE D KNIFEBLADE 4 AC DISCONNECT 1 MODULE MODEL JKM425N-54HL4-B LOCKABLE NEMA 311 UL STAMPED 06/18/2024 LISTED MODULE(W) 425 MODULE PTC(W) 398.1 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. MODULE Isc(A) 13.58 REPRODUCTION IN ANY FORM I MODULE VDc(V) 38.95 (E)UTILITY METER TO UTILITY EXPRESSLY FORBIDDEN WITHOUT PRIOR GRID WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. MODULE Imp(A) 13.13 3 MODULE Vmp(V) 32.37 (N)ENPHASE (E)150ARATED Current COMBINER BOX MAIN SERVICE PANEL 1 PH,12=40V 60HZ R en e w a b!a s 1 CELL WIRELESS (E)150ABREA ER Engineering 2 A MODEM C. (TOP FED) CURRENT RENEWABLES ENGINEERING INC. 1750 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 IQ GATEWAY PHONE(951)-405-1733.WWW CRENG.CO 1 BRANCH OF 12 A - PV MODULE N CONTRACTOR INFO N)15A• I I I L (N)20A I I • 2 BRANCH OF 12 I I I LISTED ED IPDE TAP VIA UL 12 0 M (N)20A I I •� LISTED IPC CONNECTOR PV MODULE N �` 1 1 4 (N)FUSED •'my' CZSYSA I—— ——— —1 (N)20A/7� i i AC DISCONNECT ! ` J r\ (N)60A FUSE • I I ELEMENT ENERGY LLC. 7470 SOUND AVENUE.MA'mTUCK, }-------- , ■'I I NEWYORK,11952 L---------- -- ---- - PH:(631)7797993 L—————— se�ices@e2sys.com —————————————————— ———— I I Licence-ME-52689 3 BRANCH OF 11 I (MASTER ELECTRICIAN) PV MODULE N — -----J 1-#6AWG COATED Licence-HI-67461 1f r GEC,COPPER TO THE MAIN (SUFFOLK HOME IMPROVEMENn J B C GROUND ROD OR TO WATER MAIN. ROBERT MARTINEZ (E)GROUNDING ELECTRODE —_ CONDUCTOR#6 BARE COPPER 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 AHJ TOWN OF SOUTHOLD NOTE: LONG ISLAND POWER AUTHORITY 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS UTILITY (LIPA) AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. I PV SUMMARY 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH SYSTEM SIZE PROPER JUNCTION BOX AT EACH END PER 690.31A (KWDC) STC 425 X 35 = 4875 PTC 398.1 IXI351= 3,934_ SYSTEM SIZE 1120 @240 WIRE CALCULATION (KWAC) MODULES 35 )IN KO SOLAR STARTING ADJUSTMENT MAXIMUM JKM425N-54HL4-B STARTING TEMPERATURE ENPHASE CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT MICROINVERTER 35 IQ8MC-72-M-US TAG QTY. SIZE (AWG) DESCRIPTION SIZE&TYPE AMPACITY RATING (°C) APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS IN RACEWAY 310.15(B)(3)(a) IN RACEWAY 2 12 SKU: Q-12-RAW-300, THHN A N/A FREE AIR 30 90° 15.96 0.96 1 28.80 19.95 1 g THWN-2 BARE COPPER-(GROUND) Rev Description Date A INITIAL DESIGN 611812024 3 6 THWN-2 COPPER-(L1,L2) B 1 8 THWN-2 COPPER-(GROUND) 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 P ROJECTNA &18/2024 3 6 THWN COPPER-(L1,L2,N) C 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 ER 1 8 THWN COPPER-(GROUND) PV-40 ELECTRICAL KID Exp:09/30/2025 ROOF MOUNT SOLAR PERMIT PACKAGE ��OFNEwy �-1 Q1 0 A. 44 ROBERT MARTINEZ �° °F 14.875 KW DC GRID TIED PHOTOVOLTAIC SYSTEM r ti 3600 PEQUASH AVE, CUTCHOGUE, NY 11935 `rFpp� 10 6793NP���� AERIAL VIEW VICINITY VIEW 2024 CODE INFORMATION GENERAL NOTES: SignedDRAWINGS ESUB SUBJECT THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY REPRODUCTION IN ANY FORM IS POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT l 2020 BUILDING CODE OF NEW YORK STATE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES RENEWABLES ENGINEERING INC 2020 RESIDENTIAL CODE OF NEW YORK STATE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED 2020 EXISTING BUILDING CODE OF NEW YORK STATE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE Current 2020 FIRE CODE OF NEW YORK STATE UNDERSIGNED s ` 2020 MECHANICAL CODE OF NEW YORK STATE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 IE t 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT 2020 PLUMBING CODE OF NEW YORK STATE SUCH AS GeOCeI 2300 CLEAR SEALANT Engineering 20 ENERGY CONSERVATION CODE OF NEW YORK STATE 7, THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL 2017 NATIONAL ELECTRICAL CODE JURISDICTION AND THE UTILITY IS OBTAINED CURRENT RENEWABLES ENGINEERING INC. r. � � 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, 1750 cHlcnco Ave SUITE J-ta RIVERSIDE CA 92507 E� "R MECHANICAL,OR BUILDING ROOF VENTS PHONE(951)-405-1733 VNMCRENG CO �} HJ TOWN OF SOUTHOLD 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS • THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE CONTRACTOR INFO 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED LEGEND CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA uM UTILITY METER PM PRODUCTION METER REGULATIONS CZSYS 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" SP MAIN SERVICE PANEL I NNV INVERTER 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY ELEMENT ENERGY LLC. GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. 7470 SOUND AVENUE.MATTITUCK, BUILDING INFORMATION COMBINER UB SUB PANEL 15 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. NEW YORK.11952 PH:(631)779 7993 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. services@e2sys.com AC DISCONNECT LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE Licence-ME-52689 1 STORY HOUSE SINGLE FAMILY RESIDENCE NEC,THE INSTALLATION STAN DAR DS/MANUFACTURER'S RECOMMENDATIONS AND IF (MASTER ELECTRICIAN) REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. Licence-HI-6ROV ❑ 7461 MODULE IQ IQ CONTROLLER 2 (SUFFOLK HOME IMPROVEMENT) ITS CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U ROOF OBSTRUCTIONS 18 ABOVE UROO SED SUO FACEO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" ATT BATTERY 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE ROBERT MARTINEZ H AP N : 1000103001400000000 ® 36"ACCESS PATHWAYS RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN QH Q.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH 3600 PEQUASH AVE, SHEET INDEX 1$ ACCESS PATHWAYS OPEN SPACE OR TYPE THAN IN MINIMUM 3N ALUMINUM CONDUIT CUT TOWN OF SO,NY 11935 AC ESS DISCONNECT 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, AHJ TOWN OF SOUTHOLD ROOF ACCESS POINT STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO LC LOAD CENTER THE PURPOSE INTENDED: PV-1.0 COVER PAGE � JUNCTION BOX UTILITY LONG ISLAND POWER AUTHORITY (LIPA) PV-2.0 SITE PLAN - Be MAIN BREAKER a SEPTIC TANK PV SUMMARY ENCLOSURE SYSTEM SIZE STC 425 X 35 = 4.875 PV-2. I ROOF PLAN LEACH LINES Kwoc) AUTOMATIC TRANSFER SSS STRUCTURAL NOTES : RTC 398 t x as=13 saa PV-3.0 STRUCTURAL TS SWITCH 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE SYSTEM SIZE 1120 @240 PROPANE TANK (KWAC) PV-4.0 ELECTRICAL 3LD © PERMANENT ANCHOR O WELL COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE MODULES 35 JKM4INKO SOLAR PROPOSED PV INSTALLATION ONLY. MICROINVERTER 35 ENPHASE PV-4.1 ELECTRICAL SLID O 2.THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. IQ8Mo72-M-US PV ELEVATION O TEMPORARY ANCHOR Z POWER LINES NO LADDER ACCESS 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS IL INSTALLER LADDER (STEEP GRADE MUST FOLLOW MANUFACTURER GUIDELINES AND PV-4.3 ELECTRICAL PHOTOS OR GROUND LEVEL REQUIREMENTS. PV-5.0 'BOM S❑ STUB-OUT OBSTRUCTIONS) 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL PV-6.0 SIGNAGE & PLACARD ® As GAS SHUT OFF CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. Rev Desaiptlon Date SKYLIGHT 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR A INITIAL DESIGN 6/18/2024 PV-7.0 SPECS+ WATER SHUT OFF INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE H2O RESTRICTED ACCESS INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY O SERVICE DROP INCONSISTENCY BETWEEN SITE VERIFICATION AND PROJECT# NA CONDUIT FOLLOWING:ROOF 2 2x8 RAFTERS @ 16" OC SPACING WITH DATE DRAWN 611 812 02 4 RAIL MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 11.5 FT. DRAWN BY ER RAFTER ROOF 3 2x10 RAFTERS @ 16"OC SPACING WITH MAX SHEET# PV-1 O ATTACHMENT UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. TITLE COVER PAGE Exp:09/30/2025 R324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON I SEPARATE ROOF PLANES, LEGEND OF NEw y FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON 0 `P R( A. ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. I�C(1 I I /�C AVE / FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM r C QU AS A b MSP MAIN SERVICE PANEL � 36INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE r SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING COMBINER THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS fF�A 106793 t�1 ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS �c AC DISCONNECT WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR F Nr MECHANICAL EQUIPMENT. 99 -5 MODULE L� I II _ R324.6.2 SETBACK AT RIDGE: I ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 _ __ ;i ned on:06/17/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN r •' 36"ACCESS PATHWAYS THESE DRAWINGS ARE SUBJECT TO AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A `' •' COPYRIGHT HORIZONTAL RIDGE. 1 •! • -•. j REPRODUCTION IN ANY OFORM IS LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 1 '°•� -' �•°• 18��ACCESS PATHWAYS EXPRESSLY FORBIDDEN WITHOUT PRIOR PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A PROPERTY LINE I • - • ~ I WRITTEN APPROVAL FROM CURRENT 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A •" •.:: .• a. . i ROOF ACCESS POINT RENEWABLES ENGINEERING INC HORIZONTAL RIDGE. �� u •° R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS ' �'•• • ` • i Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE I i• , — — In AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE i } 55'-4" • ` / / \ Engineering PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. • I \ 1 e•-•a:•�:s s• -'•y j \ CURRENT RENEWABLES ENGINEERING INC. NOTES: 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED I y i a �° ' ° . I Q(� PHONE:(951 µ W 05-1733.NNV CRENG CO ON ACTUAL SITE CONDITION AND DRIVEWAY = .`'� I j C ' `v \1 CONTRACTOR INFO MEASUREMENTS. - 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS 1 a' •` y °' ° :° + i / / INCORPORATED INTO THE 2017 NEC AND UL STANDARD 1741. i , / ROOF ACCESS POINT � � � I Mon* 3. EXISTING ROOF VENT SHOULD NOT BE • ' ' r I MSP UM / COVERED. ROOF LINE CZSYS� I .• .-•- I \ / ELEMENT ENERGY LLC. i -.: � s .. ► i \\ / 7470 SO E �ITUCK, ROOF OBSTRUCTION �- NEW YORK, I 52 • / PH:(631)779 7993 • • 1 r _ services@e2sys.com ! • 1 Licence-ME-52689 rI •s I (MASTER ELECTRICIAN) °a 1Licence-HI-67461 FENCE J(/ +• (SUFFOLK HOME IMPROVEMENT .22'-11"I FENCE ENLARGED VIEW ROBERT MARTINEZ 16'-6" T .. 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 f14 ROOF ACCESS POINT AHJ TOWN OFSOUTHOLD UTILITY LONG ISLAND POWER AUTHORITY LO (LIPA) PV SUMMARY t SYSTEM SIZE � 1 (K WDC) STC 425 X 35=14.875 PTC 398.1 X 35=13.934 SYSTEM SIZE PROPERTY LINE KWAC) 20 �z4G I JINKO SOLAR MODULES 35 jKM425N-54H L4-B53'-10I t MICROINVERTER 35 IQ8MCASE -US I , f 1 f 1 Rev Description Date A INITIAL DESIGN 6/18/2024 L� 991-511 [DATE ROJECT# NA DRAWN 6/18/2024 RAWN BY E.R SITE PLAN SHED HEET# PV-2 0 TITLE SCALE: 3/64" = 1'-0" SITE PLAN Exp:09/30/2025 ARRAY AREA LEGEND �,ipF NEwY ARRAY ROOF ROOF TOTAL ROOF ROOF AZIMUTH #OF AREA AREA AREA AREA uM UTILITY METER �� p0��t A zq0 ,� TILT MODULES (Sq.Ft.) (Sq.Ft.) COVERED BY COVERED BY ARRAY(%) ARRAY(%) SP MAIN SERVICE PANEL #1 20° 298° 4 84.08 2439 3.45 COMBINER #2 20° 118° 3 63.06 2439 2.59 c❑ n 2 93 30° 208° 6 126.12 2439 5.17 30.16 �c AC DISCONNECT SF 106793 #4 20° 298° 11 231.22 2439 9.48 P E QU AS H AVE MODULE #5 20° 118° 11 1 231.22 2439 9.48 L' ROOF OBSTRUCTIONS - 36"ACCESS PATHWAYS Si IN Dn:RE SUBJECT THESE DRAWINGS ARE SUBJECT TO ® 18"ACCESS PATHWAYS COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS RAIL EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RAFTER RENEWABLES ENGINEERING INC. ATTACHMENT Current I C I Engineering I MSP UM I _ — 1� � � CURRENT RENEWABLES ENGINEERING INC. L —— 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA92507 PHONE:(951)-405-1733.NWVW.CRENG.CO 3'�ol J CONTRACTOR INFO 10 a Is 01 AC � 1 ' EZSYSgu ELEMENT ENERGY LLC. v 7470 SOUND AVENUE,MATTITUCK, I ( I I I I I ( I I I I I ( I I I I I I I \\ // NEWY1)7711952 ROOF#3 PH:(639 7993 Licence-ME 52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) ROBERT MARTINEZ - - - - - - - - ENLARGED VIEW 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 (N)35 JINKO SOLAR JKM425N-54HL4-B - - - AHJ TOWNOFSOUTHOLD — - - LONG ISLAND POWER AUTHORITY r UTILITY (LIPA) ,i — PV SUMMARY SYSTEM SIZE STC 425 X 35 =14,875 (KWDC) I PTC 398.1 IX 135 I=113,934 SYSTEM SIZE 1120 @240 _— - _— — — (KWAC) —.— - - — MODULES 35 JINKO SOLAR y 1KM425N-54HL4-B >. .1i MICROINVERTER 35 IO8MENPHASE C-72-M-US l � Rev Description Date A INITIAL DESIGN 6/18/2024 ROOF#1 ROOF#2 ROOF#4 ROOF#5 PROJECT# NA DATE DRAWN 6/18/2024 DRAWN BY ER ISHEET# PV_2,2ROOF PLAN TITLE SCALE: 1/8" = 1'-0" ROOF PLAN TABLE 1 TABLE 2 Exp:09/30/2025 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX p��Cif A. i f NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG ��o0�c 4pF'� S2 ATTACHMENT IRONRIDGE QUICKMOUNT HALO ULTRA 2 GRIP ROOF 1 20° COMP SHINGLE RAFTER 2"X8" 16" 64" 24" s3 RAIL IRONRIDGE XR-100 RAIL ROOF 2 20° COMP SHINGLE RAFTER 2"X8" 16" 64" 24" ROOF 3 30° COMP SHINGLE RAFTER 2"X8" 16" 64" 24" �J' 106793 ROOF 4 20° COMP SHINGLE RAFTE 2"X10" 16" 64" 24" ROOF 5 200 COMP SHINGLE RAFTE 2"X10" 16" 64" 24" Signed on:06/17/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Curren n Engineering CURRENT RENEWABLES ENGINEERING INC. MODULE 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE:(951)-405-1733.WWW.CRENG.CO S3 CONTRACTOR INFO S2 im®m TABLE . PENETRATION CZSYSA ROOF GUIDE FOR INSTALL ELEMENT ENERGY LLC. TWO OR MORE ROWS OF PANELS 7470 SOUND AVENUE,MATnTUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 2. " INEMBED. I I I I I I I I I I I I I I I I I I I I (MASTER ELECTRICIAN Licene- - (SUFFOLK HOME IMPROVEMEN T ROBERT MARTINEZ (2)-#14 x 3" SELF DRILLING 3600 PEQuasH AVE, STRUCTURAL SCREWS TO CUTCHOGUE,NY 11935 S, EXISTING STRUCTURE I I I I I I I I I I I I I I I I i I I I AHJ TOWN OF SOUTHOLD ( I I I I I I I I I I I I I I I I I I I LONG ISLAND POWER AUTHORITY ENLARGED VIEW UTILITY (LIPA) STACKED STAGGERED FULLY STAGGERED PVSUMMARY F'K STC 425 X 35=14.875 PTC 398.1 X 35=13,934 ONE ROW OF PANELS 1120 @240 35 ANKO SOLAR KM425N-54HL4-B MODULE 35 ENPHASE IQBMC-72-M-US I I I I I I I I I I I I I To I I I I I I I I I I I I I SEE ENLARGED VIEW FULLY STAGGERED STACKED/STAGGERED Rev Description Date A INITIAL DESIGN 6/18/2024 �— ROOF LDATEDRAVMM NA 6/18/2024 E.RATTACHMENT DETAILS PV-3.0 STRUCTURAL BACKFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST ��pF E(1,yp� S.NO. ITEMS DESCRIPTION CITY. �P ��MAN/ 46.55 X 1.25 = 58.19AMPS 60A FUSES-OK � �1O �G'G � JINKO SOLAR 1 PV MODULE JKM425N-54HL4 B 35 ACCOUNT NUMBER -9623031300 C: 2 • w METER NUMBER-98298054 m 099126 2 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 35 yN ENPHASE IQCOMBINER �O CTRICP� MODULE JINKO SOLAR 3 COMBINER 5/5C 1 AROSSlONP�' MANUFACTURER 60A RATED D322NRB MODULE MODEL JKM425N-54HL4-B 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 STAMPED 06/lW024 LOCKABLE NEMA 3R UL LISTED MODULE(W) 425 THESE DRAWINGS ARE SUBJECT TO MODULE PTC(W) 398.1 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS MODULE Isc(A) 13.58 (E)UTILITY METER EXPRESSLY FORBIDDEN WITHOUT PRIOR TO UTILITY WRITTEN APPROVAL FROM CURRENT MODULE VOC(V) 38.95 GRID RENEWABLES ENGINEERING INC MODULE Imp(A) 13.13 3 MODULE Vmp(V) 32.37 (N)ENPHASE (E)150ARATED Current COMBINER BOX MAIN SERVICE PANEL 1PH,120/240V 60HZ n 1 A MCELL ODEM WRELESS (E)150A/BREAKP MAINER = Engineering BREAKER 2 COMMS (TOP FED) CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 10 GATEWAY PHONE(951)405-1733 VWWI.CRENG CO 1 BRANCH OF 12 PV MODULE N KN)15A:� CONTRACTOR INFO t ---- %ti r (N)20A/T� I • LISTED IPDE TAP VIA UL O I r\ I •� LISTED IPC CONNECTOR 9MEM 2 BRANCH OF 12 I (N)20A/i\ I 4 PV MODULE N �\ I /T E2SYSV (N)FUSED • (N)20A I I AC DISCONNECT L J '/\ I (N)60A FUSE • ELEMENT ENERGY LLC. — i i •� 7470 SOUNDNEW YORK,11952�ITUCK, ———————— '1 L----- L---------- -- 4./b ---- ——————————————————— PH:(631)779 7993 I services@e2sys.com 2689 3 BRANCH OF 11 I I Licence-ME-ELECTRICIAN) PV MODULE N — -----J I (MASTER ELECTRICIAN) t r GEC,COPPER TO THE MAIN I Licence- IMPROVEMENT) (SUFFOLK HOME IMPROVEMENn J B C GROUND ROD OR TO WATER MAIN. L———————— ROBERT MARTINEZ (E)GROUNDING ELECTRODE I— CONDUCTOR#6 BARE COPPER 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 AHJ TOWN OF SOUTHOLD NOTE: 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS UTILITY LONG ISLAND POWER AUTHORITY (LIPA) AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. PVSUMMARY 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH SYSTEM SIZE PROPER JUNCTION BOX AT EACH END PER 690.31A (KWDC) STC 425 x 35 =1a 875 PTC 398.1 X 35 =13.934 SYSTEM SIZE 11.20 LID240 WIRE CALCULATION KWAC) MODULES 35 JINKO SOLAR ADJUSTMENT MAXIMUM JKM425N-54HL4$ STARTING ENPHASE STARTING TEMPERATURE MICROINVERTER 35 IQBMC-72-M-US CURRENT FACTOR FOR ADJUSTED CURRENT CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION TAG QTy. SIZE(AWG) DESCRIPTION SIZE&TYPE AMPACITY RATING (°C) APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO 310.1 ACTT 6) CONDUCTORS 310.ACTO2)(a) CONDUCTORS AMPACITY CONDUCTORS IN RACEWAY 310.15(B)(3)(a) IN RACEWAY SKU: Q-12-RAW-300, THHN A 2 12 N/A FREE AIR 30 90° 15.96 0.96 1 28.80 19.95 Rev Description Dale 1 8 THWN-2 BARE COPPER-(GROUND) A INITIAL DESIGN 6/18/2024 3 6 THWN-2 COPPER-(L1,L2) B 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 1 8 THWN-2 COPPER-(GROUND) PROJECT# NA DATE DRAWN 6/18/2024 3 6 THWN COPPER-(L1,L2,N) C 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 DRAWN BY ER 1 8 THWNCOPPER-(GROUND) SHEET# PvAo TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING OF NEIV MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST r\� Y� �Q 46.55 X 1.25 = 58.19AMPS 60A FUSES-OK S.NO. ITEMS DESCRIPTION QTY. MAN/�ZO , G, JINKO SOLAR * t� _ 1 PV MODULE JKM425N 54HL4-B 35 ACCOUNT NUMBER -9623031300 c: D W METER NUMBER-98298054 M 099128 2 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 35 z cp ENPHASE IQ COMBINER �O < CTRIGI ESSIO p MODULE JINKO SOLAR 3 COMBINER 5/5C 1 A�4p �1P MANUFACTURER 60A RATED D322NRB F MODULE MODEL JKM425N-54HL4-B 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 STAMPED 06/18/2024 LOCKABLE NEMA 313 UL LISTED MODULE(W) 425 THESE DRAWINGS ARE SUBJECT TO MODULE PTC(W) 398.1 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION MODULE ISc(A) 13.58 EXPRESSLY FORBIDDEN WITHOUT PRIOR MODULE Voc(V) 38.95 (E)UTILITY METER TO UTILITYTY ERITTEN NEWABLES EOVAL FROM NGINEERING INC ENT MODULE Imp(A) 13.13 3 MODULE Vmp(V) 32.37 (N)ENPHASE (E)150ARATED Current COMBINER BOX MAIN SERVICE PANEL ?� c 1 PH,120I240V 60HZ � - e*� 1 CELL WIRE LESS (E)150ABRE BREAKER �` Engineering 2 A MODEM COMMS TOP FED) CURRENT RENEWABLE$ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 IQ GATEWAY PHONE.(951)-405-1733,VWWV.CRENG.CO 1 BRANCH OF 12 PV MODULE N CONTRACTOR INFO (N)15A:� (N)20A./I\ � (N)LINESIDE TAP VIA UL LISTED IPC CONNECTOR 2 BRANCH OF 12 (N)20A.///[\ 4 PV MODULE N r\ �� C2SYS9 (N)FUSED �' 1 (N)20A/j\ AC DISCONNECT �/\ (N)60A FUSE ELEMENT ENERGY LLC. ��� 7470 SOUND AVENUE,MATiITUCK, NEW YORK,11952 �b • PH:(631)779 7993 services@e2sys.com Licence-ME-52689 3 BRANCH OF 11 (MASTER ELECTRICIAN) PV MODULE N Licence-HI-67461 HOME IMPROVEMENT) B C ROBERT MARTINEZ (E)GRUNDING ELECTRODE CONDUCTOR#6 BARE COPPER 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 AHJ TOWN OF SOUTHOLD NOTE: 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS UTILITY LONG ISLAND POWER AUTHORITY (LIPA) AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. PV SUMMARY 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH SYSTEM SIZE PROPER JUNCTION BOX AT EACH END PER 690.31A (KWDC) STC PTC 398 x 35=14875 .1 IX1351=113934 WIRE CALCULATION SYSTEM SIZE(K WAC) 11 20 @240 MODULES 35 JINKO SOLAR ADJUSTMENT MAXIMUM JKM425N-54HL4-B STARTING HASE STARTING TEMPERATURE MICROINVERTER 35 IQENP 8MC-72-M-US CURRENT FACTOR FOR ADJUSTED CURRENT CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION TAG QTY. SIZE(AWG) DESCRIPTION SIZE&TYPE AMPACITY RATING (°C) APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS IN RACEWAY 310.15(B)(3)(a) IN RACEWAY SKU:Q-12-RAW-300, THHN A 2 12 N/A FREE AIR 30 90° 15.96 0.96 1 28.80 19.95 Rev Description Dale 1 8 THWN-2 BARE COPPER-(GROUND) A INITIAL DESIGN 6/18/2024 3 6 THWN-2 COPPER-(L1,L2) B 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 1 8 THWN-2 COPPER-(GROUND) PROJECT# NA DATE DRAWN 6/18/2024 3 6 THWN COPPER-(L1,L2,N) C 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 DRAWN BY ER 1 g THWN COPPER-(GROUND) SHEET# Pv-4.1 TITLE ELECTRICAL SLID ELEVATION ��pF NE�,y �P o�E MAN�,p_ p'P'� I I D W TO CONDUIT RUN I I i 09912B z UNDER ROOF EAVE I I °A ` CTRIC-1 RoFESS►oNP I I STAMPED 06/18/2024 I I THESE DRAWINGS ARE SUBJECT TO FRONT CORNER MAIN SERVICE PANEL I COPYRIGHT PROTECTION R IS LAW. REPRODUCTION IN ANY FORM S OF HOME EXPRESSLY FORBIDDEN WITHOUT PRIOR (INTERIOR) i WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC Current Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)405-1733.NMMV.CRENG.CO I FROM AC FROM CONTRACTORINFO IQ COMBINER 5/5C DISCONNECT METER' I FUSE DISCONNECT n 0 ®— — i i EZSYSgu 1 , I I ELEMENT ENERGY LLC.ENPHASE 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) ROBERT MARTINEZ 3600 PEQUASH AVE, TO MSP TO MSP CUTCHOGUE,NY 11935 X. I METER (INTERIOR) AHJ TOWN OFSOUTHOLD LONG ISLAND POWER AUTHORITY UTILITY (LIPA) PV SUMMARY I THE HEIGHT OF THE (KVOCM SIZE STC 425 X 35=14.875 UTILITYMETER IS 4' SYSTEM SIZE PTC 3981 X 35 =13.934 (K WAC) 11 20 @240 JINKO SOLAR MIN 4 8" MODULES 35 JKM42SN-54HL4-B ENPHASE MIN 48" I I MICROINVERTER 35 IOSMC-72-M-US I I MAX 72" MAX 72" I I Rev Description Date A INITIAL DESIGN 6/1 812 02 4 I I P ROJECT 24 I I ELEVATION EXISTING SERVICE PANEL PHOTOS ��pF NEW y �P OBE MANz 0- t �2 cG * r ' D W m osslza 2 yN�OA CTRIrG, Rp SsloNP� STAMPED 06/18/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewabtes Engineering CURRENT RENE:WABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)405-1733.W W W.CRENG CO CONTRACTOR INFO • mar EZSYS9 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 - ` (MASTER 671461 (SUFFOLK HOME IMPROVEMENT) ROBERT MARTINEZ 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 AHJ TOWN OF SOUTHOLD LONG ISLAND POWER AUTHORITY UTILITY (LIPA) PV SUMMARY _ SYSTEM SIZE (KWDC) - STC 425 X 35 =14.875 11 PTC 398.1 X 35 = 3.934 SYSTEM SIZE(K WAC) 1120 @240 MODULES 35 JINKO SOLAR J KM425N-54HL4-B MICROINVERTER 35 ENPH ASE IO8MC-72-M-US Rev Desuiption Date A INITIAL DESIGN 6/18/2024 PROJECT NA DATE DRAWN 6/18/2024 DRAWN BY ER SHEET# PV-43 TITLE ELECTRICAL PHOTOS MATERIAL LIST pFNE�,Y o '�P� OE MAN/ 'P ELECTRICAL EQUIPMENTS " W QTY. PART TYPE PART NUMBER DESCRIPTION R` 099126 z 35 MODULE JKM425N-54HL4-B JINKO SOLARJKM425N-54HL4-B ZN�o G 35 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US Ss%oNP� 1 AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED STAMPED06/18/2024 1 COMBINER X-IQ-AM1-240-5/5C Enphase IQ Combiner 5/5C THESE ARE SUBJECT TO 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS COPYRIGHT PIROTECTION BY US LAW REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current r Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733.WWW.CRENG.CO CONTRACTORINFO BREAKER/ FUSES [2SYSgu QTY. PART TYPE PART NUMBER DESCRIPTION ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 2 FUSE 60A FUSES GENERAL 60A FUSES NEW Y1)779119 PH 799 :(6393 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) s Licence- E-5ervices-ME-5289 689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) ROBERT MARTINEZ 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 AHJ TOWN OF SOUTHOLD RACKING LONG ISLAND POWER AUTHORITY QTY. PART TYPE PART NUMBER DESCRIPTION UTILITY (LIPA) 2 RAILS & SPLICES XR-100-204A XR100, RAIL 204" CLEAR PVSUMMARY L(KWDC) STC 425 X 35 =14 875 38 RAILS & SPLICES XR-100-168A XR100, RAIL 168" CLEAR PTC 3981 X 35 =13934 14 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE XR100 (KW(KW2G JINKO11NK0 SOLAR 35 JKM425N-54HL4-B44 CLAMPS & GROUNDING UFO-CL-01-A1 UNIVERSAL MODULE CLAMP, CLEAR 35 ENPHASE IQ8MC-72-M-US 52 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL 13 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 102 ATTACHMENTS QM-HUG-01-M1 HALO ULTRAGRIP, MILL 204 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev I Description Date A INITIAL DESIGN 6/18/2024 102 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE PROJECT# NA DATE DRAWN 6/18/2024 DRAWN BY ER SHEET# PV-5.0 TITLE BOM CAUTION c�oF NE(.�y ,r,P QE MA/yj 0- MULTIPLE SOURCE OF POWER Co �CSi D n ' W m 099128 = PHOTOVOLTAIC �A � crRlcP� ��C9 • • . • . .. M �OFESSIONP 690.12 ; STAMPED 06/18/2024 Q N THESE DRAWINGS ARE SUBJECT TO Q COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR LiJ WRITTEN APPROVAL FROM CURRENT PV ARRAY d RENEWABLES ENGINEERING INC. TURN RAPID • SHUTDOWN SWITCH TO ■ ' • ■ ■ ' • Current THE "OFF" POSITION TO AC •• •• • 1VOLTS SHUT DOWN PV SYSTEMIJL� Aj 690.14,690.15,s9o.5a — Eng!^ee' AND REDUCE SHOCK CURRENT RENEWABLES ENGINEERING INC. WARNING" 1760 CHICAGO AVE SUITE J-13 RIVERSIDE CA 92507 HAZARD IN THE ARRAY PHONE(951)405-1733.WWWCRENGCO 690.56(C)(1)(B) DUAL •• ■ SOURCES CONTRACTORINFO SECOND • • PHOTO-,VOLTAIC RATED OUTPUT ■ ■ , • AMPS COMBINER AC NORMAL OPERATING VOLTAGE-240 VOLTN o E25YSgq 690.54 OPTIONAL SOLAR LOAD CENTER ELEMENT ENUI, ATT AC DISCONNECT 7470 SOUND AVENUE,MATfITUCK, ARRAY 52 MAIN SERVICE PANEL NEW s@e2sy9co PH:(631)779 7993 services@e2sys.com UTILITY METER Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) JAB PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL ROBERT MARTINEZ PANEL IS AC DISCONNECT PER NEC 690.17 3600 PEQUASH AVE, CUTCHOGUE,NY 11935 INVERTER OUTPUT CONNECTION AHJ TOWN OF SOUTHOLD • NOT RELOCATE THIS NEC 690.31(G)(3)&(4),CRC R324.7 LONG ISLAND POWER AUTHORITY • ■ ■ ■ DEVICEIENT UTILITY (LIPA) PV SUMMARY (UNLESS BUSBAR IS FULLY RATED) PHOTOVOLTAIC • • • POWER • ■ • ■ SYSTEM SIZE STC 425 X 35 = 14.875 705.12(D)(2) PTC 398.1 X 35 =13.934 SYSTEM SIZE 1120 @240 EVERY 10'ON CONDUIT AND ENCLOSURES (KWAC) MODULES 35 JINKO SOLAR JKM425N-54HL4-B MICROINVERTER 35 EN PHASE IOBMC-72-M-US NOTES: 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A INITIAL DESIGN 6/1 812 02 4 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. PROJECT# NA C. AERIAL FONT. DATE DRAWN 6/1ai2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-60 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS E A G L E Front Side Back 1!Y.rmm iG•b59 t°min No.of Half Cells 10812 x 541 M 0 D U L E 5 - - - - Dimensions 1722.1134.35mm 167.79.44,65.1.38 inch) N _ Weight 22.Okg 148.5ibsl THE MOST - Front Glass H.gh Tr Anti-Reflection Coating e� High Transmission,low Iron,Tempered Glass P N Frame Anodized Aluminum Ailoy DEPENDABLE _- -` THESE DRAWINGS ARE SUBJECT U TO - - -' Junction Box IP68 Rated COPYRIGHT PROTECTION BY US LAW. -_-� Output Cables 12 AWG,1400mm 155.12m1 or Customized Length REPRODUCTION IN ANY FORM IS _ __. _.. EXPRESSLY FORBIDDEN WITHOUT PRIOR SOLARPRODUCT _ _ _ �_ Connector Staubli MC4 WRITTEN APPROVAL FROM CURRENT _t Fire Type Type 1 RENEWABLES ENGINEERING INC. Pressure Rating 540OPa ISnowl&240OPa(Windt -_-- - --, - Curren; EAGLE 54HM G6 TEMPERATURE CHARACTERISTICS Engineering 0`�n 420-440 WATT is N-TYPE TOPCON � Length:x2mm Temperature Coefficients ofPmax -0.29%/°C -.- --Y CURRENT RENEWABLES ENGINEERING INC. Temperature Coefficients of Voc -0.25%/°C Width x 2mm P 1760 C HONE:(AVE SUITE 1-13.RIVERSIDE.0 92507 Positive power tolerance of 0-+3% n i PHONE(951)�05-1733.NNVW CRENG CO P � � Height:x imm Temperature Coefficients of Isc 0 045%7°C � Row Pitch:z 2mm ° u Nominal Operating Ceti Temperature(NOCT) 45±2°C CONTRACTOR INFO • NYSE-listed since 2010,Bloomberg Tier 1 manufacturer • Top performance in the strictest 3-1 party tabs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS r� • Automated manufacturing utilizing artificial intelligence Current-voita e&Power-Volta a Temperature Dependence CZ SYS° 9 9 P P Operating Temperature(•Cl -4D•C-r85°C � • Curves(440W1 of Isc,Voc,Pmax Maximum System voltage 1000VOC Vertically integrated,tight controls on quality us 9 -- -- ----------------- +• - -• Premium solar factories in USA.Vietnam,and Malaysia Maximum Series Fuse Rating 25A ELEMENT ENERGY LLC. r 747D SOUND AVENUE,MATTITUCK, u _.._ m NEW YORK,11952 PH.(631)779 7993 m 9 KEY FEATURES ° - °'° 's sLi elnce-ME-52689 1m PACKAGING CONFIGURATION (MASTER ELECTRICIAN) • 3 Licence-HI-67461 OSuperior Aesthetics i-� -___ _ ITwo pallets=One stacki (SUFFOLK HOME IMPROVEMENT) Black backsneet and black frame create ideal look for 31pcs/pallets,62pcs/stack.806pcs/40 HO Container residential applications. °° ° 1. •vouage(vj • ; ROBERT MARTINEZ N-Type Technology 3600 PEQUASH AVE, O N-typeceils with J;nko's in-house TOPCon technology WARRANTY CUTCHOGUE,NY11935 offers better performance and improved reliability- Ceti Temperature f°CI P Y 25-year product and 30-year linear power warranty AHJ TOWN OF SOUTHOLD Thick and ToughGLASS 1"year degradation not to exceed 1%,each subsequent year not to FRAME exceed 0.4%,minimum power at year 30 is 87.4%or greater. UTILITY LONG ISLAND POWER AUTHORITY Fire Type 1 rated module engineered with a thick frame, 3.2mm front side glass,and thick backsheet for added durability. RIPA) PV SUMMARY Shad Tolerant ELECTRICAL CHARACTERISTICS SYSTEM SIZE STC 425 X 35 =14875 Twin array design allows continued performance Module T a JKM420N-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-B JKM435N 54HL4-8 JKM440N-54HL4-8 (KWIC) even With shading by trees or debris. Type PTC 398.1 X 35 13.934 STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT SYSTEM SIZE 1120 @240 Maximum Power IPri 420W 316Wp 425W 320W 430Wp 323Wp 435Wp 327W 440W 331Wp O Protected Against AU Environments D P P D P MODULES 35 lKM4 SOLAR p Certified to withstand humidity,heat,rain,marine environments, Maximum Power Voltage tVmpl 32.16V 29.95V 32.37V 30 19V 32 58V 30.30V 32.78V 30,50V 32.99V 30.73V JKM425N-54HL4-B wind,haitstorms,and packed snow. MICROINVERTER 35 ENPHASE Maximum Power Current limp) 13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A IO8MC-72-M-US Warranty Open-circuit Voltage(Voc 38.74V 36.80V 38.95V 37.00V 39.16V 37,20V 39.36V 37.39V 39.57V 37.59V 25-year product and 30-year linear power warranty. short-circuit current Itse 13.51A 10.91A 13.58A 10.96A 13.65A 11.02A 13.72A 11 08A 13.80A 11.14A Module Efficiency STC t%1 21.51% 21.76% 22.02% 2T28% 22.53% 'STC: .W,Irradiance 1000W/m, Cell Temperature 25°C AM=1.5 s ° AM=1.5 Wind Speed 1m/s kPROJECT Description Date • IS09001:2015 Quality Standards • 15045001:20180ccupational E NOCT:-!-irradiance 800W/m �Ambient Temperature 20 C • IS014001:2015Emironmental5tarldards Health&Safety Standards CE C l u5 INITIAL DESIGN 6/18/2024 ,_-..-..., *Power measurement tolerance:x3% - _ - • IEC61215,IEC61730 certified products • UL61730 certified products _ LISTED The company reserves the final right for explanation onany of the information presented hereby.JKM420-440N-54HL4-S-F1-US � . BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US KO BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US .IinKO u NA DA AWN 6/18/2024 DRAWN BY E.R SHEET If PV-7.0 TITLE MODULE SPEC u ENPHASE. I08MC Microinverter Commonly used nodule pairings' our 260-460 wlAodule compatibility To meet compatibility,PV modules must be within the following max.input DC voltage and max.module Ir Module compatibility can be checked at rrttos://er11N1ase.com/installers/microinverters/calculator. THESE DRAWINGS ARE SUBJECT TO MPPT voltage range V 25-45 COPYRIGHT PROTECTION BY US LAW. Operating range V 15-W REPRODUCTION IN ANY FORM 1 EXPRESSLY FORBIDDEN WITHOUT PRIOR Min./Max.start voltage V 22/58 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.input DC voltage V 60 Max.continuous operating DC current A 14 _ ' I Current Max.Input DC short-circuit current A 25 Max.module l,_ A 20 Engineering Overvoltage class DC port D CURRENT RENEWABLES ENGINEERING INC. DC port backfeed current mA 0 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 ------ -- -- - - --- - — PHONE(951)-405-1733.VWMW.CRENG.CO PV array configuration Ungrounded array,no additional DC side protection required:AC side protection requires max 20 A per branch clicult CONTRACTORINFO Peak output power VA 330 315 Max.continuous output power VA 320 310 Q8 M C M i c ro i n ire rte r Nominal grid voltage(L-L) v 240.split-phase(L-L).180` 208.single-phase(L-0,120' 9MOM Easy to install Min./Max.grid voltage' v 211-264 183-229 CZ SYS Our newest I08 Series Microinverters are the indust s first micr rid�formin software- Lightweight and compact with plug- Max.continuous output current A 1.33 1A9 ry g�. and-play connectors --_ ELEMENT ENERGY LLC. defined microinverters with split-phase power conversion capability to convert DC power to Nominal frequency Hz 80 7470 SOUND AVENUE.MATTITUCK, AC power efficiently.The brain of the semiconductor-based microinwerter is our proprietary Power line communication(PLC) NEW YORK,11952 application-specific integrated circuit(ASIC).which enables the microinvuxter to operate In between components Extended frequency range H, 47-68 PH:(631)7797993----------- ------- —------------------ grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed AC short circuit fault current over three services@e2sys.com digital is and has superfast response times to changing loads and rid events,alleviating Faster installation with simple two-wire cycles A-• 2.70 Licence-ME-52689 g' logic pe po g' g g rg cabling (MASTER ELECTRICIAN) constraints on battery sizing for home energy systems. Licence-HI-67461 Max.units per 20 A Ill branch circuit 12 10 (SUFFOLK HOME IMPROVEMENT) High productivity and reliability Total harmonic distortion vb <5 Enpho- • Produces power even when the grid is ROBERT MARTIN EZ • down* Overvohage class AC port III ------------------- 3600 PEQUASH AVE, More than one million cumulative hours AC port back feed current inA 19 CUTCHOGUE,NY 11935 of testing settingt 0 Power factor setting Part of the En hale Energy S IQ8 Series Microinverters redefine Class II double-insulated enclosure AHJ TOWN OF SOUTHOLD P 9Y stem.Y Grid-tied power(actor(adjustable) 0.85leading...0.85 lagging I08 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered LONG ISLAND POWER AUTHORITY the IQ Battery.IQ Gateway,and the million cumulative hours of power-on PV modules Peak efficiency 'x 97.4 97.2 UTILITY (LIPA) Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency vc 97.0 96.5 software. limited warranty of up t0 25 years. PV SUMMARY Microgrid-forming Nighttimeconsumption mw 33 25 SYSTEM SIZE Complies with the latest advanced grid MECHANICALs. KW�) STC FTC 3 98. X 35= 3.934 425 x 35= 4.975 support _ 240 Ambient temperature range -40'C to 65°C(-40°F to 149'F) SYSTEM SIZE 1120 @240 Remote automatic updates for the K WAC) latest grid requirements Relative humidity range 4%to 100%(condensing) SOLAR MODULES 35 1 1KM4KM425N-54HL443 DC connector type Staudi MC4 ENPHASE • Configurable to support a wide range _._.._. -_ - -------------- MICROINVERTER 35 IQ8MC-72-M-US Of grid profiles Dlmenslons IN a W a Et Weight 212 mm(8.3")°175 mm(6.9")a 302 mm(L2Nr Ll kg(2A3 ids) Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Coding Natural convectiwt-no farts 472018(UL 1741-SB) — — — - integrated MC4 connectors. conforms with various regulations when 15 Approved for wet locations:Pollution degree Yes,PD.3 installed according to the manufacturer's instructions. Enclosure Class II double-insulated,corrosko resistant polymer is enclosure MOTE: IQ8 Microinverters cannot be mired together with Environ.category;UV exposure rating NEMA Type 6;outdoor previous generations of Enphase micranvertersCOMPLIANCE Rev Description Date (IQ7 Series.IQ6 Series.etc.)in the same system. 10 Gateway is regoned to change the default grid CA Rule 21(UL 1741-SA).UL 62109-1,IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C222 NO.107.1-01 A INITIAL DESIGN 6/182024 -Meets UL 1741 oMy when irnLlled with IQ 5yatsm Comrd4,2 and 3 proMa at the time of installation m meal the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and Authority HwkV JvedkOW(AH)aqusaments. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. C 2023 Enphasa Energy.All rights raarvao Enpnxse,the a and CC logos.C.and certatn other rrurks lhtw at (1)No a O.—al DC/AC ratio. PROJECT al NA httpi,.#enprl—room,✓1 demark-u sago- delinas are trademarks of Enphaw Energy,Inc.In the US and other countrias. (2)Nominal voltage range can be wended beyond ramlnal if required by the utility. IQ9MC-MCI-OSH-0004B-3.0-EN-US-2023-10-18 Data sublect to charge. KMW-kOC4-0DOH W QIFOOF3D-ENi im 16-2023-10-1a (3)Limas they m ay vary.Refer to local requlreems to define the number of mlcrdnvwtws per branch In your area. DATE DRAVVN 6/182024 DRAWN BY E.R SHEET X FN-7.1 TITLE MICROINVERTER SPEC ENPHASE. ® IQ Combiner 5/5C ITmanaen(W•N•DI 375 cm•495 c�„.18 B cn,(M)5-•)e5'•e�'7.Kp:n�s 210e'(S3S�nl with•maan.i�q bacWf nc«m.�s.rmnea,...rw.ewe.axewar..u.�awr...�.ayraafwwoa.xnr+ w'V° THESE DRAWINGS ARE SUBJECT TO n C«+b,w SIA+O-1a,4240-5) r�w+snp Ul61Ci210_OS%:.caiwnp4or�rvilavq(x25%).antlp Ba+vYnottarW(s23%). A��p;.r,+tamparature rarga -fOCbM'C f-gFb1CF) krk.aeaaf4rarfov.rf.viroae+ec+� COPYRIGHT PROTECTION BY US LAW. -EaP.+aSF nea�ah.scw.Mpe»uwr wwea caan om.ab wma,.ee..w.wtpaaew««kcnvr. �^° w+ua+mrw.P+im.pwlr aNala REPRODUCTION IN ANY FORM IS +ruregt w.Cp3p-05%).mw.urIDtnn m«itonrq 11.5%)aM C IM-1^«gnu-^9(+251) 0u ..MttLror+"NWAbr 3kpdWu0w.Nob.huetlm EXPRESSLY FORBIDDEN WITHOUT PRIOR .an..Frp�...umwc...n n�u.re,oa..�ceFu.poeu-ui-os- -os).ew..,r.e. WRITTEN APPROVAL FROM CURRENT �,*+�roa.nwY we z0Aw50Abaaksaputs;14+PAA co corMNba RENEWABLES ENGINEERING INC. - tnabw..b,rennwrr4rotro Awc�PP.cond�l.. wke.b.a M.mlaOmn4fndaawn:nmzYOAvw�vov+w.dctprf rFaAr.lwdaraadurotrocPPoe•=vnaxt«� pf er+Y P��.fucuIIbaarA pOtl.wYw mePWbmla mu�wrrW maruV.^•"�WcmnaMnvw.remore maimwwc..ena , nap.w dMaFWu.6 g Synn � c��- +sbc«�cb� Current d.lar eDAbaba anhaugr�«+trf•n(ia+awarbwYw and 4.20 Ab.aafer brfwaa..pp Serise communiu+an(mvramaf m�.wvowtY) BiakM.Ci�.00e-db•.ired rvm�urratian rrtn lD BeltcY Sp vdln 5vnan C«vraM«3/36. IIIC/a,..wrowsaMq anion SF y+bpe!ed Paw.I�nec«nnvs+r�lion b n 9was If«unslw+ .' C-Gnawer harts Cacun bwEs.2-Pae.n4.5 A 'W'+'�' Up ro 2AODnwral8,530 krU Engineering X-W-Y/F240-5 �'•a•�w w._F, eoz.)wWn(a.lewz�cwiseNa.ro.w.�aobw m.F�a�wcae+l o-d+wr+f..+w - X-110_PAIIII•240-5C p� T� �� Y �w �� wro w, CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 c^nL m.a evrrva ib.rab rmee .m,..ymn.ra�psY.+.*cvn.o�.3�w.�+a+rc.p Aa+«r 5P a„e+vrnn PHONE:(951)J05-1733,WVWJ.CRENG.CO IQ Combiner 5/5C Erp.wxwPWe Corf.cr(PrAY a�p.pcamAin.3C) 4Ci LTF-A11pWhrmod.n(CELLMODE,+-4 M-Vp 5). o5-•prr-Nabdad PWI El— �O+�P.+:.3D23.Ca:a�br Cat 6)U1P[,M.rr,ubb:ea F+NudW).,a c«..ec[ip+ctM Ems Gad Mraph I.— �t ao.a«.c sw, v sm;romcoru n-�o,re cau„r.iMoeafcvnr+ cEut-m-absp-05«CELMooEM-M De-aTos awemmpcuee.x) CONTRACTOR INFO Th.10 CwrEklw S,Ct..andolas/Kr .gL.ip.swst Moa 0.gWatci—anE -awr*—W5aaTM trawwahewkwsard gG>te aysRaBlsbn byprwndegamwftw,. k_A .ie Gsfe."t. ... , Dgnav Dry,:input/a4pA trpidaTwml *� pre-oired aaWWtarforraidsMW aPO�alfans-IC Can8is.5/SC ales Nrad eo.Crol cammwer�ioc asdmridN CELL1pOFLt Y+-CE n,..: rn ..:. ...vnwn wrtha 5-vav T-YeDbaata p+ar� Use 2A ibCi Csnae4CO----- lbg9aa.T'3/JfAD'g4CCIN54fi-0YbrpererYSp owmnaecatdnandsmtpal6k am 10 systan Cb._w 3/3G and la Ban y5P. -ys y.dey h+phafel/ebie Can.tet .__ ___.___ __._. ..___-_ __ - (CELLMODBF-MI-O65P-OS).Piy CFt1YDDFAa-Y1-Oe As-C^_ 46-has.d iF-Ml celkYa•nvder:..hac-wa.AT6T Ma Wn Accw mrrt Uvl nnaa fa.aanrWpebal.aet Otap as..VandaneeidaMoarunY9WfbOlta�liWraPP jamm Tha W ConEa.w5.•SC.IOSaTNa lflpOetwrterf.105yftwnCvnAw 3/3G,.WlOBaDay fh IQCard_5C Swa+sFsan eN?JU.}arwm C]Ia spa QEiA®iNCL71kI�SriesdaNbriss(JtX rap.araa �w �a UP wMO Cweusption Moro M 13t"CT,rdarr 0.o8aliur Cf � gy SP W—de acantpMev�w Enw Sy—, GMbwfsafdt-e.-ahem n.axD.w.w.so.«eo).M.n+wwrf F..ran eN?11o6,atT3oe.waWo6<.a,+nr..Y.. -s pp—f afie VA-� �e a.�aa� 9o_na�. CZSYS ProvidesP TMn nM v C+cvf ba.bs((:cnaaa WEMa.) Ana-2nasdwahn Met-2 2W� ,-'iW.eNC-FJ-2P.2a0/-e.srd BW-2(M-2P- Wab APi SaeM '�asielmv-r4arWrtcmri� __—___.__.__ 4e.wns Ty wad ca+wunpw. —1 API Sw sae 1«bw 1Pf vtorkg ly,_ .Ey w ,,,�yy,��y p CP„a,w yx ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUC K, SA-(lR.-PCBAt n Dnaaer�aPlaowrwv waaaa van t0la(PCB)br p C«ndnoe SISC �fe x-p-rM-wrasA um-aa.n.n�nPow.tnEmrat-e 5.wwanerw✓.(+u.er.,.a> to nat cvlicsAczz rt,.lma TmeacaL wrtTs.clwacEs o03.Now-zmsca-zae. NEW Y 11952 rci,NcsA W cant.,.wren W onaw,v tn.taern-tz2 n)o 1 re.e -1.EFE tsn 2t1tl11LL not-%aa Fe).IEEE Xi105/C31P PH'(631)1)77 779 7993 W Sar4lMOYrvaten WSysmm Cowreaw 3lSG Mouras To onesnd with cerawW Canpka tt.Pahcnon mnriq:lNSicttzO aavary dar05(wpP6cfion) seNices@e2sys.com The l,Bh-pon iarrwiOrfd-reedy WSw Prpvdes m=09r'dnfe.cpnrmeti«: baakefa xA-COW32-PCBA+ np.emnwnCOMMSi(n-D2P•^Na ekaA Dw.d(PCa)Aa p(a�d'rw 5/SC Licence-ME-52689 Uicrc wrters(108.W.and 10B Series)Wk dHy device(MID fu tk—Ifty hq 5tppwts baRwn.back.and side the a+tahwwnpracees. au[wlmocasy dstacWV end t.6—end YU �t�t�s�� �� �V SO w u �. a� (MASTER ELECTRICIAN 61 syvwn'—Ord Power m baokW power. Sappwts up kaa 2-PoL-branch to sxxamc«,edw. EP2006gt-WQUS00 Licence- IMPROVEMENT) cachet wr 240 VAC Pk+9-Ic&m*wf Syr.rop arenaowr,,Y MVIOwc.(n� (SUFFOLK HOME IMPROVEMENT) -- (nw:+ckad.d) &-c.,p tzsA town-,ir-�, rosy.r«nc«.t•Pua�7 Fpz000tm-wT4IX9D1 90AwaalPVba bcp , FJ e,ttaY EMCNARDE-YID-NA ENCWIIK9E-n-ID-NA.ENCNAR9f-3T-ID-N4 Fla:NAaGE-IOf-W-NA Fwn r ,.aa.p nkAIC ROBERT MARTINEZ .Bkhawpt,taem W-F wad+.wrkw psYa«n C«nrP8w3 scz000tticz4oDs01.sc2000nre24ousol +w easy VA-R fw,p w....,a.,.«na.o,oP..w+n.P tm.a n«a wr.«aae> 64 A coMMs-crt-o2° astray 1oeATTEar-sP-w NA 3600 PEQUASH AVE, Brve*.reaeslsoW aM/ nvV) Wtobv2•pafatitlon 80.51wr.esQ wGFIABB THOI Srw dw'Mmd P^araam(OG)kraslue. wE.br .,yfwk-W" CUTCHOGUE,NY 11935 Duabl,NRTL-.-wteted NEw type 3q barMvcur Gads rnno(rp/.) BD A P1 a,ab as Oensaea—Aw4n lC Ge—krwtar u,nneo W B.ttey 5P W Load Coaatroiler +daan�an+«.: Edgy k,wyatad AC—y�lw.�k w,dw si. Hepf prwmmeessama�aPpatacas e.A.— poa+e..rb r.r nAv1s A..oyoErsf.,..iE.mr�mPkn.a AHJ TOWN OF SOUTHOLD fold-repYcaebb WBD�AT IIieranYe!ters. d,nwya Brdd oetage to owkrdtee:wrgy -5-yea.krtned wrracrty cc..m rot and w..Neatery H.. Praa.ct nwvorap CT 2W AsPYdcora Pe+wnfeaard wea top Ga+aaey .. 2�Iabv redact lo,e both, Po¢arr. aOekckdadfvbwhthe c«w.wPraan,,.«.mn.acrtcr-zo0�aawP) A Par a2ooAdaro-.aid.�n.an,..b.r:,..a.,dw.awim<roe.. UTILITY LONG ISLAND POWER AUTHORITY (LIPA) W C.Id—SKUs p aaak.Y elaYlapLZ 200A damp-a+yloaar..laYebn.ar b p a..ynswip.ecaba wrth the O[o ® UL1741 Leted -- ____ __--... __-.__ PV SUMMARY C Oa �O� IMICROINVERTER YSTEM SIZE ------- k Aaa..wtwkraFv.waem.�.wry.y�mw..aw..r.rr.e..>••+.u:.esre e+,.law.a,>w..f.am.we,.us Y•P:tn.�.m..M..-.d.a.n. STC 425 X 35 =14.87 5 Yevhr.ted - .ik....rp.a.aa.ems WDC) RTC 398.1 X 35=13.934 ywnawy YSTEM SIZE 1120 @240 •E«v«,.nr-w.=et.ana�ar,�,mrpn�,. t.R WAC) e zoMe.a.aer.oa..u•�a�.,��e,erg..u�.weenw.Ie.�amtr.m..�n.k..a. ODULES 35 JINKO SOLAR -.t:.-.-vim-.n-. .. r.-.n.•.+w•. ..a.aa...eaec�or..�na.ua...eusm.wr z.sa.mr,,..,n.ea2ac �v5c�..Pnean.en,.t'.wan,•ou,.r...nw•w. 1KM425N-54HL4-B o.,..y..-k-.wa. .oc-sacar.aom.-ao-a..rsmu+m Ioc-sSonw-oopor ao-u+rs-2m.nr-rn ncaron«ex.-�..Pe.a,w.ae+u,cwam-m ncssmw-Doom-ao-twua-».mm ENPHASE 35 IQ8MC-72-M-US Rev Description Date A INITIAL DESIGN 6118/2024 PROJECT# NA DATE DRAWN 6/18/2024 DRAWN BY E.R SHEET# PV-72 TITLE COMBINER SPEC IRONRIDGE XR Rail° Family XR Rail° Family The XR Railg Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar is Not Always Sunny design loads,while minimizing material costs. Depending on your location,there is an XR Rail"to match. Over their lifetime,solar panels experience countless THESE DRAWINGS ARE SUBJECT TO extreme weather events.Not just the worst storms in years, COPYRIGHT REEPRO UCTION NEANYON BY US FORM IS but the worst storms in 40 years. High winds capable of EXPRESSLY FORBIDDEN WITHOUT PRIOR FROM ripping panels from a roof,and snowfalls weighing ERNEWABLES VAL ENGINEERING NEERING INCCURR ENT enough to buckle a panel frame. Current XR Rails®are the structural backbone preventing these results-They resist uplift, XR10 XR100 XR1000 p protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among Engineering and efficiently transfer loads into the rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built t0 handle° CURRENT RENEWABLES ENGINEERING INC. building structure.Their Superior no snow.It achieves spans up to 6 feet, wind and snow conditions.while also extreme climates and spans up to 12 y while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 Spanning capability requires fewer ,Cf PHONE-.(951)-405-1733,VWVW.CRENG.CO roof attachments,reducing the 6'spanning capability 10'spanning capability 12 Spanning capability CONTRACTOR INFO number Of roof penetrations Moderate load capability Heavy load Capability Extreme load capability ( Clear&black anodized finish Clear&black anodized finish Clear anodized finish and the amount of Internal splices available Internal splices available Internal splices available installation time. _ a a nit Rail Selection E2SYS10 The table below was prepared in compliance with applicable engineering codes and standards.* Values are ELEMENT ENERGY LLC. based on the following criteria:ASCE 7-16, Gable Roof Flush Mount. Roof Zones 1 &2e, Exposure B, Roof 7470 SOUNEW YORK,E I 92 TTITUCK, Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. PH:(631) sereices@e2sys.com Licence-ME-52689 ..f llllllll ", (MASTER ELECTRICIAN) :.' —._-- Licence-HI-67461 � • (SUFFOLK HOME IMPROVEMENT) Snow 90 ROBERT MARTINEZ Force-Stabilizing Curve 90 Sloped roots generate both vertical and lateral 120 3600 PEQUASH AVE, forces on mounting rails which can cause them to CUTCHOGUE,NY 11935 bend and twist.The curved shape of XR Rails None 140 XR10 XR1000 AHJ TOWN OF SOUTHOLD is Specialty designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme 160 - - - UTILITY LONG ISLAND POWER AUTHORITY weather and a longer system lifetime. (uPA) 90 PV SUMMARY 120 SYSTEM SIZE STC 425 X 35= 4.875 / 20 (KWDC) 140 EC 398.1 X 35= 3.934 SYSTEM SIZE - (KWAC) : 11.20 @240 160 IINKO SOLAR MODULES 35 1KM42SN-54HL4-B 90 MICROINVERTER 35 IQ8MEN PHASE C-72-M-US 30 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 XR Rails are tronRidge"offers All XR Rails are made of 6000-series 40 compatible with a range of tift leg aluminum alloy,then protected with an ' 160 FlashFooe-and options for flat anodized finish.Anodizing prevents surface A other pitched roof roof mounting and structural corrosion,while also providing 80 160 Rev Description Date attachments. applications. a more attractive appearance. q INITIAL DESIGN 6I78I2024 120 160 •Table is meant to be a simplified span chart for conveying general rail capabilities Use approved certification letters for actual design guidance. PROJECT# NA 0 2023 IrwRidge,Inc.Ail rights resewved.Visit—wAronridge.corn or call 0 2 4 00 DATE DRAWN 6/1 812 DRAWN BY ER ISHEET# PV-7.3 TITLE RAIL SPEC Z IRONRIDGE QuickMounta Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home. solar attachments THESE DRAW NGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop- COPYRIGHT PROTECTION BY US LAW P P � REPRODUCTION IN ANY FORM IS Due t0 recent Innovations, many asphalt shingles EXPRESSLY FORBIDDEN WITHOUT PRIOR have bonded COUFSeS.A mount that protects without - WRITTEN APPROVAL FROM CURRENTRENEWABLES ENGINEERING INC. the need to pry shingles can really speed things up. Current Halo UltraGrip`(HUG')is here to respect the roof. Its Halo is a cast-aluminum barrier that encases the ' UltraGrip,our industrial-grade.foam-and-mastic Engineering seal.This allows HUG to accelerate the installation CURRENT RENEWABLES ENGINEERING INC. process and provide the utmost In Waterproofing protection.Give your roof a HUG.' Hit the rafteO Good to go! Miss the rafter?Try it again. Still no luck?Install - 6D CHICAGO AVE SUITE J-13 RIVERSIDE CA 9250 PHONE-(951)405-1733,VWVW CRENG.CO When you find a rafter,you can move on.— Nace another screw to the left or right If If more than 3 screws miss the rafter. Only 2 RD Structural Screws are needed.001 rafter is found,install 3rd and final Screw. secure six screws to deck mount it. CONTRACTOR INFO Muni-Tiered Waterproofing HUG.-utilizes a multi-tiered stack of components to provide revolutionary Trusted Strength & Less Hassle waterproofing protection The Halo cast- C 2 SYS aluminum.raised-perimeter foundation sunoundstheUltraGrlpbase—a foam- Structural capacities of HUG` were reviewed in Cked mastic seal combination that man load directions.with rackingrail running ELEMENT ENERGY LLC. evenIS water intrusion by adhering y g 7470 SOUNDNEWA ORK,AVENUE 52 TTITUC K, ing with the shingle surface cross slope Or Up slope In relation t0 roof pitch. PH (631)799 7993 services@e2sys.com c aGrlP is Part For further details,see the HUG certification Licence-ME-52689 h auickMOunY (MASTER ELECTRICIAN) letters for attaching to rafters and decking. Licence-HI-67461 Gt line, (SUFFOLK HOME IMPROVEMENT) IronRidge designed the HUG, in combination —_ ROBERT MARTINEZ UltraGrip' Seal Technology with the RD Structural Screw to streamline HUG UHraGnp utilizes a state-of-the- Installs,which means the following: 3600 PEQUASH AVE, art seal design that uses a unique, CUTCHOGU E, NY 11935 foam-and-mastic combination.The foam-backed adhesive provides an No prying shingles AHJ TOWN OF SOUTHOLD entirely new flashing system Inat No roof nail interference conforms and adheres to every rook t25-Yearrranty LONG ISLAND POWER AUTHORITY and cranny of composition shingles. ranteed tree No pilot holes necessary UTILITY (LIpA) filling gaps and shingle step-downs - No sealant(in most cases) (up to 1/8'In height). No butyl shims needed PV SUMMARY - - - SYSTEM SIZE STC 425 X 35 =14 875 (KVVDC) RTC 398.1 IX1351=113934 Attachment Structural Water Seal UL 2703SYSTEM SIZE 1120 9240 (KWAC) Load • • • MODULES 35 JINKO SOLAR 1 K10425N-541-41-4-13 •� MICROINVERTER 35 EN PHA5E IQ8MC-72-M-US Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG to the roof rafters.the roof deck or both with our custom-engineered HUG has been and certified for the UL 441 Section UL 2703 mechanical •4 � ". ., RD(ratter-or-deck)Structural Screw The RD tested and rated to compliance with 1 27"Rain Test"and and bonding Q Triple Rated&Certified Structural Screw anchors HUG to the roof to Respect the Roof- ' i� with an EPDM sealing washer.completing support 1004 (Ibs) of the International TAS 100(A)-95 requirements. See Rev Description Date 6s Ui.2703.441(27) the stack of waterproofing barriers See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual A INITIAL DESIGN r,�,erzoza Intertek TAS 100(A)-95 backside for more installation information of lateral load. ASCE/SEI-7. i Test"by Intertek. for more into. PROJECT# NA Cc)2023 IronRidge,Inc.All rights reserved.Visit www.ir-patents.com for patent information.Vei,sion 1.03 DATE DRAWN 6/18/2024 DRAWN BY E R SHEET# PV-7 4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. I 28357 Industrial Blvd. RON RI DGE Hayward.CA 94545 Hayward, 545 1-800-227-9523 1-800 227 9523 IronRidge.com I R O N R I D G E Iron Ridge.com Attn:Corey Geiger,COO,IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following Date:September 7t",2021 Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1 The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1 5-1 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 2 Wind speed shall conform to ASCE 7-16 Fig,26 5-1 B(for Risk Category II)and applicable state&local REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The county/city amendments to the IBC. No special wind topographic features are included and both topographic WRITTEN APPROVAL FROM CURRENT contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(Kn)and wind ground elevation factor(Ke)are taken as 1.0. RENEWABLES ENGINEERING INC. proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface- PV modules are supported by extruded aluminum XR Rails 3. Snow load used in the span tables is the ground snow and shall conform to ASCE specified Fig.7.2-1 and Current and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof applicable state&local ,it shall fi amendments to the IBC. If the local jurisdiction specified snow load is in the 9 9 P format of a flat roof snow,it shall first be converted to a ground snow following the local building code) \() attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables No special snow conditions are considered EngineerinC that is fastened to the underlying roof structure- Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding,retention,or ponding snow No rain-on-snow surcharge load is components are shown in Exhibit EX-0015 considered.The span tables do not apply to buildings which are intentionally kept below freezing.kept just CURRENT RENEWABLES ENGINEERING INC. above freezing,Gf unheated. 1760 CHICAGO AVE SUITE J-13 RIVERSIDE CA 92507 g PHONE(951)405-1733 VWVW CRENG CO The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: CONTRACTOR INFO listed below,for the load conditions and configurations tabulated in the attached span tables (a)For ground snow no greater than 42psf.Ss s 2.Og for Site Class A,B,C,&D. ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Ss s 1.0g for Site Class A, B,C,&D. ®01 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:SS<1.5g for Site Class A,B,C.&D. ��SYS 2020 Building Code of New York State(BCNYS-2020, Published in November 2019) 5 - 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in which the zones share the same External Pressure Coefficients(GCp).Roof zones comprising each group along ELEMENT ENERGY LLC. Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall services@ersys com Licence-ME-52689 the respective loads and configurations listed,covering wind exposure categories B, C,&D, roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load (MASTER ELECTRICIAN) ASCE 7-16 for gable&hip roof profiles, and roof slopes of 8°to 45`. The tabulated spans are applicable when the &configuration condition from the span tables,or 36". Licence_HI.(SUFFOLK HOME IMPROVEMENT) following conditions are met: 7 Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. ROBERT MARTINEZ 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment fastener). 8. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: 3600 PEQUASH AVE, CUTCHOGUE, NY 11935 a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2/3 of end spans AHJ TOWN OF SOUTHOLD 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated b) BOSS Splice can be installed at any location within a span. based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. LONG ISLAND POWER AUTHORITY 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If UTILITY (LIPA) 3. The underlying roof slope,measured between the roof surface and horizontal plane..is 8'to 450. such conditions are encountered contact support@ironridge.com. Pv SUMMARY SYSTEM SIZE KWDC) STC 425 X 35 =14.875 ( 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured PTC 3981 IX1351=113934 SYSTEM SIZE 11 20 A240 from grade,does not exceed 30 feet. (KWAC) MODULES 35 )INKO SOLAR 1 KM425N-54HL4-B 5. A clearance from the underside of the array to the roof surface of 2'minimum shall be provided and the MICROINVERTER 35 EN PHASE IQ8MC-72-M-US height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not exceed 10'. 6. Module length and area shall not exceed the maximum values listed on the respective span tables 7 All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Rev Description Date Mount Installation Manual and other applicable standards for the general roof construction practice A INITIAL DESIGN 6/18/2024 :u 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-1 ©2021 IronRidge.Inc. NY Flush Mount System Certification Letter 2 PROJECT# NA DATE DRAWN 6/18/2024 DRAWN BY ER SHEET# PV-7.5 TITLE CERTIFICATION 28357 Industrial Blvd 28357 Industrial Blvd. Hayward,CA 94545 Hayward,CA 94545 A� IronRidge.co23m IRONRIDGE 1-800- IRONRIDGE IronORidge.om3 e.co 10. Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations(orphan modules)using modules with a length greater than 67.5",1The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no clamps shall not be installed in regions that experience round snow loads of 70 sf and greater.Such consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting P 9 P 9 P g THESE DRAWINGS ARE SUBJECT TO scenarios are shown by asterisks in the applicable span tables. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the COPYRIGHT PROTECTION BY US LAW b) I will function within a module's design load ratings Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR CAMO meets the dimensional requirements shown in the figure below and that the module selected is WRITTEN APPROVAL FROM CURRENT suitable for the environmental conditions of a particular project. at NE O O^ O RENEWABLES ENGINEERING INC w lJ.i Sincerely; P��r.NG x09 Current ModuteGloss/Ceps � n*, � _ -�` 1j- r�'+r��E'S t? UJIa ( _____ __ 15:45: 16 Engineering — � o �Oq D�r.,70 �� —0 O O CURRENT RENEWABLES ENGINEERING INC. 1760 PHICAGO AVE ONE(951)JSUITE I EJ 13 RIVERSIDE CA C092507 L�12 CONTRACTORINFO Gang Xuan.PE Senior Structural Engineer x a M r*1 Figure,:CAMOReqL*wwft E2SYS9 Span values for Exposed and Edge module conditions,as defined below, are included in the attached span ELEMENT ENERGY LLC 7470 SOUND AVENUE,MATTITUCK, tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge NEW YORK,11952 modules shall be the lesser of the following two:(1)The span value for the Exposed or Edge module condition; PH:(631)7797993 2 The span value determined b site winds speed and round snow load.Additionally, irrespective of the lesser services-ME-5 689 com ( ) P Y P 9 Y+ P Licence-ME-52689 span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage (MASTER ELECTRICIAN) limitation detailed in note 9 of page 2 shall apply to the respective condition. Licence-HI-67461(SUFFOLK HOME IMPROVEMENT) 1. Exposed Module conditions: ROBERT MARTINEZ 3600 PEQUASH AVE, A module is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free CUTCHOGUE, NY 11935 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge, rake.or AHJ TOWN OF SOUTHOLD hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from its free edge to any LONG ISLAND POWER AUTHORITY other adjacent array or panel is greater than 4 feet. UTILITY (LIPA) PV SUMMARY The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed SYSTEM SIZE STC 425 x 35 =,a 875 Modules Kvvoc) PTC 398.1 X 35 =13.934 SYSTEM SIZE 11 20 9240 (K WAC) O SOLAR 2. Edge Module conditions: MODULES 35 JKM425N-54HL4-B E N PH ASE A module is defined as an Edge Module when its distance from any side of the module to its facing MICROINVERTER 35 InsMCa2-M-US perimeter roof edge(such as eave,ridge,rake or hip)is less than 2 times the height of the array(2h2) where h2 is measured from the roof surface to the top surface of the module. The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Additionally,if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered for this span adjustment. Rev Description Date A INITIAL DESIGN 6/18/2024 "2021 IronRidge.Inc. NY Flush Mount System Certification Letter-3 Cc, IronRidge.Inc NY Flush Mount System Certification Letter-4 PRDJECT# NA DATE DRAWN 6/18/2024 DRAWN BY ER SHEET# PV-7 6 TITLE CERTIFICATION