Loading...
HomeMy WebLinkAbout50890-Z of SOOryo`o Town of Southold * P.O. Box 1179 53095 Main Rd COUNn Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45691 Date: 10/26/2024 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ADDITION AND ALTERATION Location of Property: 2135 Marlene Ln Laurel,NY 11948 Sec/Block/Lot: 144.-3-12 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 05/09/2024 Pursuant to which Building Permit No. 50890 and dated: 07/01/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built" finished basement with one bedroom, one bathroom and playroom, to existing single family dwelling as applied for. The certificate is issued to: 2135 Marlene Ln LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50890 09/11/2024 PLUMBERS CERTIFICATION: Chris Singleton 09/17/2024 4 uth r' ed ignature ��o�SufFat,r�o TOWN OF SOUTHOLD BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE • SOUTHOLD NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50890 Date: 7/1/2024 Permission is hereby granted to: 2135 Marlene Ln LLC 11 Buck Hill Ln Pound Ridge, NY 10576 To: legalize "as built" finished basement to existing single-family dwelling as applied for per SCHD approval. Additional certification may be required. At premises located at: 2135 Marlene Ln, Laurel SCTM #473889 Sec/Block/Lot# 144.-3-12 Pursuant to application dated 5/9/2024 and approved by the Building Inspector. To expire on 12/31/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $1,454.00 CO-ALTERATION TO DWELLING $100.00 Total: $1,554.00 Building Inspector ho��pF SO(/r�,ol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1]971-09.59 �� • �o sean.deviinCa-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Marlene Ln LLC Address: 2135 Marlene Ln city,Laurel st: NY zip: 11948 Building Permit* 50890 section: 144 Block: 3 Lot: 12 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor 1 st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 13 Ceiling Fixtures, Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 2 Smoke Detectors 1 Main Panel A/C Condenser Single Recpt Recessed Fixtures 14 CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 3 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 6 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " Finished Basement Inspector Signature: Date: September 11, 2024 S.Devlin-Cert Electrical Compliance Form Copy os%sf°1rc� Town Hall Annex h� ��y� Telephone(631)765-1802 54375 Main Road P. O:,�o�;1.1,79a„.. y Z South'oltl;N '11971-0959 f • �1 DIDD ���d� ; '�• r S E P 1 8. 2024 BUILDING DEPARTMENT TOWN OF SOUTHOLD BU•DWG DEPT. TOWN PF S OLID' CERTIFICATION Date: l 2 Building Permit No. o Owner: : (Please print) Plumber: OUAe-- (Please print) I certify that the solder used in the water supply system c tai less than 2/10 of 1% lead. (Ptantbers Signature) Sworn to before me this day o �, 20 Notary Public, Y1t ref/Lr-ounty AMY M.SCHLACHTER NOTARY PUBLIC,STATE OF NEW PORK Registration No.01SC5039767 Qualified in Suffolk County Commission Expires February 27;20-21 1 q souryolD # TOWN OF SOUTHOLD BUILDING DEPT. `y�OUrm 631-765-1802 <,Soto ANSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAUL KInNG [ ] FRAMING/STRAPPING [ FINAL 4S�1 - & l tit+ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: (9 '7 DATE R �� INSPECTO oF sooryolo qq G S 13 5 l�� 1p e L� # # T WN V SOUTHOLD BUILDING DEPT. courm,��' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] .INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ]..FIREPLACE & CHIMNEY . [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION. f ] FIRE RESISTANT PENETRATION [ . ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: J� �1 (,'r �ryl�skgm �- M��� DATE INSPECTOR 0 (� E � �I OCT - 7 2024 CHRISTOPHER G. T'AORIVIINA ARCHITECTY,t��449C' October 3,2024 Mr.Michael J.Verity,Chief Building Inspector Town of Southold Town Hall Annex 54375 Route 25 Southold,NY 11971 RE: Singleton Residence 2135 Marlene Lane Mattituck,NY 11952 Section 144 Block 3 Lot 12 Dear Mr.Verity, To the best of my knowledge and belief as a New York State Registered and Licensed Architect;the plumbing and thermal insulation represented in the As Built Finished Basement Drawing prepared by Paul H.Bosco,dated 4.28.2023 for Building Permit#50890;was installed in accordance with the 2010 Residential Code of New York State governing at the time of construction. Please let me know if you have any questions and feel free to contact me further if you require any additional information. 1011 D Sincerely,� Christoph G aormina w , Architect '9�F 029.464 �OQ� qF No Cc: Mr. Christopher Singleton,Owner 244 CALIFORNIA ROAD YORKTOWN HEIGHTS,NEW YORK• 10598 TAOR.�IINA244@GNfAIL.COM 914.447.1610 4, 0 CT - 7 2024 puildinn _)ep ment Town c. ou,hold Ii MELD INSPECTION REPORT DATE COMMENTS an I,OUNDATION (IST) --------------------------------- FOUNDATION (2N O ROUGH FRAMING & PLUMBING INSULATION PER N. Y. STATE ENERGY CODE -IVA CA NC v FINAL ot44/ ADDITIONAL COMMENTS so -1 -p'og J Sy jl� TOWN OF SOUTHOLD—BUILDING DEPARTMENT z Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o aa� Telephone(631) 765-1802 Fax (631) 765-9502 hqps://www.southoldtownny.gov » Date Received APPLICATION FOR BUILDING PERMIT ,1 For Office Use Only PERMIT NO. Building Inspector: MAY — 9 2024 A flications a_nd foriiis must.be fl{ed ouL iti,.their`enti[ety: Incompl'to ?��IRID' ,G DIE E <'a' lice#ions will not b'e ecce ted..Whereafie Applicant is not the wner;an. .,. 'g"O :Y fv oaf',. PP. P, 1. O;wner's'Authori"t66.form.(Page 2j.shall:be-completed.:;w: ;r :�- Date: �.. _ OF P_ PROPERTY:OWNER(S) R 3 f - -T Name: Z i �� qrl(►� Lo+� 11 SCTM# 1000- ( 3 12 Project Address: ] f'1gr �a� MA4- ,AV e-V-- Z Phone#: 6��b -4 -lee Email: G e i'l &J rely •ee," Mailing Address: (�al�V— N E `'1 f 4S• �CO TAGT 50 P R Nc�Name: , Sir+ Mailing Address: &cv— ta -q-b Phone#: &(6 -4`7—9a0c' Email: L`11�i5 S/,76 le, kn l 73 - F, - � ..7, %. :4:� �1^-":;L.. - :J•, :h, - l'ir:�,: - _- :J Jai' - L{NFORMATIO ,,t? `DESIGN�PROFESSIONA _ Name: TRH I See+ Mailing Address: Qp (�p1C 'L y'�-3 AGtle bo ve 0131 2 4 q 3 Phone#: �3� . �7�'� '� �,�� Email: ' _ o - NT Ci'O "i4TION:O RA R1INFOR M Name: Mailing Address: Phone#: Email: §.N'SED•C .RUCT(O " a•' . b; -DESCRIPT,ION'OF=PROPO ONST - sr :i:s - =-ir: vim•. :i�: - =ram• ❑New Structure ❑Addition Iteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Z<(0 Will the lot be re-graded? ❑Yes I(No Will excess fill be removed from premises? ❑Yes El No 1 O va -.ERt.Y' --1 NFORMATIO Existing use of property: i of property: jF1,1Nst, se�A,6 r - . I - 6 AAL6-7-��- Intended use- .. - - . .1- " Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? E]Yes*o IF YES, PROVIDE A COPY. y 'd' su0s-as,pi6iFld6a;J6, leforall' Check oWinii1ci6ir"jideli j���isiiinal Isresil;ohsilb lack Bok'Aftjdr,.AiadI4. 1646 6uildi, ziine.,� MA- .,'.'-.'Chaoter,236ofth'e!'T6Wi%Code.',.APPLJC-J��6k!:i�"Hii.iBi,'�" DE'f�o�thi,Buildiiii,DLioiOtMbntf6;.,�i 'Ru, :aUildirigVennit pursuant ;Ordinance • ' jbijil 1 �ii6"T�whof-SbuthiDid;g'uffi)lk�tount*,NiwYciika-nd'dthi?r,bpolic�ibI e Laws, additions;iiteratioft,or.fbi�riihbvii o I r,c fie 7he a0p.1cant agreett6,i housing code and regulationsand to admit di t; i n: ,ii: w iii nk� fbfnec6ssary,nsp ktqr�,qn,;preRn ses*i unishable-ai a Class A' Medncro�ijii nt to Section 2 Nork Stifte ftina, a Application Submitted By(print m []Authorized Agent &01"W*'ner Signature of Applicant: Date: IG j� STATE OF NEWYORK) SS: COUNTYOF EufrkNL being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Al (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 2 0 1 UFFANY J BEREZNY � 01olay Public-State of New Yc k Yotary-�ubli No.01 BE6 284112 Qualified in Suffolk county My Commission Expires 06/17/2(2! PROPERTY OWNER AUTHORIZATION ((Where the applican not the owner) /V A- Wh the a pp 'Can no t I 1, siding at cg4 Qa,,� do eby(Where to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 �Qcog of/C�0 BUILDING DEPARTMENT- Electrical Inspector �O Gy TOWN OF SOUTHOLD o ` Town Hall Annex- 54375 Main Road - PO Box 1179 o . , Southold, New York 11971-0959 ti01 �ap� Telephone (631) 765-1802 - FAX (631) 765-9502 ' ` iamesh(cDsoutholdtownny.gov seand(o�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: o, 13 2,4 . Company Name: -1-V •►t� Electrician's Name: Nr - -TL W License No.: Elec. email: Elec. Phone No: -7,eN -Yb-3" ❑I request an email copy of Certificate of Compliance Elec. Address.: SoQ/~ Ave J2-t vj-" N veto) JOB SITE INFORMATION (All Information Required) Name: �3S M q.rl tv►— 40 6A5 Address: 2(3� rlltr-lev� La-e Cross Street: Z� Phone No.: (94(0• 960-266 Bldg.Permit#: 5Z 99-D email: C iS Sf4 -i r/- 33 Tax Map District: 1000 Section: Block: 1JLot: BRIEF DESCRIPTION OFWORK, INCLUDE SQUARE F90TAGE (Please Print Clearly)., ., Square Footage: U Circle All That Apply: Is job ready for inspection?: EYES NO ❑Rough fn 4I� Final LJ ❑ Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 F2 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION • / plot) 6, G�) �L ( 0va PERMIT# Address: Switches , Outlets�� c G F I's Surface Sconces H H's *A UC Lts Fridge HW POOL Fans Mini Fr. WAD Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV Inst Hot DeHum Transfer HOT TUB/SPA Disc e Combo C � Cooktop Minisplit Blower ' AC AH Hood Blower Service 'Amps Have Used Sub Amps Have Used Comments f2c100 SURVEY OF PROPERT SITUATE MATTITUCK 'SOWN OF SOUTHOLD DWELLING SUFFg% r-O,JNTY, NEW ' PUBLIC WATER w N ss°Zo'so'• E 14s.7o' SCc�I�.�1�00-144-3-1 ELEV. — — — — — — — — — — ,n 13.6 •� O K N O SfRy�c ELEV. p 7J > GAS 17 3 A S B V I LSO Vo X o SERVICE '� R - 2 3- 0 8 2 4 _ Io o w DRIVEWAY (3) 8'0 x 6' GARAGE LEACHING POOLS 2135 MARLENE A-27' A-12' MATTITUCK, I`B-40' 8-29' 0 W O EXISTING ONE [n a 0 O STORY DWELLING I W = o W/ BASEMENT 0 > o' A-14' � r, A-23 B-22' A E 1 STORY J 3 B-29' 0 o A-16' 1 5 FAMILY BEDROO DWELLING o m O /z� ��" lO o o I 0 B-17' I m 0 TOTAL AREA: 2,228 SF C • 0_ w I O B F.F. 18.9WATER 0 I d r m SERVICE O'VENT W/ BASEMENT w Q Y C o �I o y � J2 , CID CONTROL LOT AREA: 18,376 SF Or z w v Lu L - Z I NORWECO BLOWER I —3 mo T E HYDRO-KINETIC GREEN LL (D 3 a MODEL 600 SYSTEM } O Z a zJU) _° � Q N U 0 ELEV. ELEV. PRIVATE 0 � 14.9 15.0 ROAD m O Q S 69°20'60" W 147.33' Lr aa)u w DWELLING u_ m N m ar o PUBLIC WATER o tLa) ako o v PECONIC BAY BLVD. NANO WELLS WITHIN 150' OFNEtyyO DANIEL R. FALAS(10, P.E. , OF SANITARY SYSTEM p- ,p •ALL PROPERTIES WITHIN 150' OF SUBJECT PROPERTY ARE Q so CONSULTING E?�GINEER SERVED BY PUBLIC WATER �' ONO DRAINS ON 94 STEUBEN BLVD., NESCONSET, NY 11767 SUBJECT PROPERTY (516) 317-72 V 05699 a�Z ;s DATE SCALE DRA G NO. p�FESSIQI 04-17-23 1"=20' 1 l Generated by REScheck-Web Software Compliance Certificate Project 2135 Marlene Lane_REScheck 050223 Energy Code: 2020 NYStretch - 2018 IECC Location: Mattituck, New York Construction Type: Single-family Project Type: Alteration Orientation: Bldg. faces 225 deg. from North Climate Zone: 4 (5331 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 2135 Marlene Lane Christopher Singleton Paulo Bosco Mattituck, NY 11952 2135 Marlene Lane PO Box 2473 Mattituck Southold Town, New York Aquebogue, New York 11931-2473 11952 631.375.7374 pauldrafter@pauldrafter.com - a -prescriptive requiremients, o e o 0 Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Wall, Partition to unconditioned: Wood Frame, 16" O.C. 112 20.0 5.0 0.044 0.045 5 5 Orientation: Front Wall, partition to unconditioned: Wood Frame, 16" O.C. 127 20.0 5.0 0.044 0.045 5 5 Orientation: Left side Door, Mechanical: Solid Door(under 50%glazing) 20 0.200 0.270 4 5 Orientation: Left side Wall, partition to unconditioned: Wood Frame, 16" O.C. 89 20.0 5.0 0.044 0.045 4 4 Orientation: Back Wall, partition to unconditioned: Wood Frame, 16" O.C. 113 20.0 5.0 0.044 0.045 4 4 Orientation: Right side Door, Storage Solid Door(under 50%glazing) 20 0.200 0.270 4 5 Orientation: Right side Basement Wall, Front: Solid Concrete or Masonry Orientation: Front Wall height: 7.0' 156 20.0 0.0 0.046 0.050 7 7 Depth below grade: 6.0' Insulation depth: 7.0' Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 1 of10 Prop.Gross Area Prop. Assembly or Cavity Cont. Window: Vinyl Frame SHGC: 0.40 9 0.270 0.270 2 2 Orientation: Front Basement Wall, Left: Solid Concrete or Masonry Orientation: Left side Wall height: 7.7' 192 20.0 0.0 0.045 0.050 9 10 Depth below grade: 6.7' Insulation depth: 7.7' Basement Wall, Back: Solid Concrete or Masonry Orientation: Back Wall height: 7.7' 169 20.0 0.0 0.045 0.050 7 8 Depth below grade: 6.7' Insulation depth: 7.7' Windows:Vinyl Frame SHGC: 0.40 8 0.270 0.270 2 2 Orientation: Back Basement Wall, Back:Solid Concrete or Masonry Orientation: Back Wall height: 7.0' 113 20.0 0.0 0.046 0.050 4 5 Depth below grade: 6.0' Insulation depth: 7.0' Door: Solid Door(under 50%glazing) 20 0.200 0.270 4 5 Orientation: Back Basement Wall, Right: Solid Concrete or Masonry Orientation: Right side Wall height:7.0' 192 20.0 0.0 0.046 0.050 9 10 Depth below grade: 6.0' Insulation depth: 7.0' Compliance Statement. The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2020 NYStretch-2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. / Mark Scott,Team Scott, LLC 7/4S /P� 3�C &&7 May 2, 2023 Name-Title Signature Date Project Notes: Basement Finish Only Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 2 of10 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2020 NYStretch - 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.ID 103.1, Construction drawings and :, > `" ;;""'. ;❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 :energy code compliance for the I: :building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. j 103.1, ;Construction drawings and ; =:"' " ❑Complies 103.2, 'documentation demonstrate "'s '' ❑Does Not 403.7 energy code compliance for . ❑Not Observable [PR3]1 ;lighting and mechanical systems. " Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. " a 3&1, Heating and cooling equipment is: Heating: Heating: ;❑Complies 4033 , sized per ACCA Manual S based Btu/hr Btu/hr i❑Does Not [PR2]2, on loads calculated per ACCA Cooling: Cooling: ;❑Not Observable Manual) or other methods ; Btu/hr ; Btu/hr ; approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 12'.1 Medium Impact(Tier 2) J3 Low Impact (Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions &Req.ID 402.1.1 ;Conditioned basement wall R- R- :❑Complies ;See the Envelope Assemblies [F04]1 insulation R-value.Where interior; R_ R- !'❑Does Not table for values. insulation is used�19) ,verification ' may need to occur during ❑Not Observable Insulation Inspection. Not ;❑Not Applicable ; required in warm-humid locations; in Climate Zone 3. 303.2 .Conditioned basement wall j, ❑Complies [F05]1 insulation installed per is = ❑Does Not manufacturer's instructions. E. ❑Not Observable ,.-,[]Not Applicable 402.2.9 Conditioned basement wall ft ft ;❑Complies ;See the Envelope Assemblies [F06]1 insulation depth of burial or j❑Does Not ;table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2:1., "A protective covering is installed ;,;_ F;V;-,`: . ❑Complies [FQTI]2 " 'to protect exposed exterior I ' r;= E]Does Not insulation and extends a '; '' ;,'_ :-.a1` �. `' .. ❑ , Not Observable minimum of 6 in. below grade. I :❑Not Applicable 4o309 , Snow-and ice-melting system .f' ❑Complies [F012].2 controls installed. t, ❑Does Not :❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) '2 Medium Impact (Tier 2) 3 1 Low Impact(Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FRl]1 ;❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- :❑Complies ;See the Envelope Assemblies 402.3.1, average). i❑Does Not ;table for values. 402.3.3, ❑Not Observable 402.5 [FR2]1 ;❑Not Applicable 303.1.3 U-factors of fenestration products{. .:; _ ❑Complies [FR4]1 are determined in accordance [,_ '❑Does Not 1 with the NFRC test procedure or [:]Not Observable ;taken from the default table. . [:]Not Applicable 402.4.1.1 ;Air barrier and thermal barrier G; :`Y.-:r - ❑Complies [FR23]1 ;installed per manufacturer's ❑Does Not instructions.An approved third- ❑Not Observable party will inspect all components ;and verify compliance. See } Not Applicable :section details and guidance ;from Table R402.4.1.1. �; i• ; 402.4.3 ;Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 r;❑Not Observable or has infiltration rates per NFRC i -i❑ryot Applicable 400 that do not exceed code ;limits. 402.4.5',.,IC-rated recessed lighting fixtures , ..,.• :.� ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not ;and labeled to indicate s2.0 cfm ;leakage at 75 Pa. ( _ ❑Not Observable -❑Not Applicable 403.3.1 ;Supply and return ducts in attics ; '' ❑Complies [FR12]1 !insulated >= R-8 where duct is I`I ( , ; ! ❑Does Not >= 3 inches in diameter and >= i. 5. :'_ 'r',.:, > ,.`: ' R-6 where < 3 inches. Supply and ❑Not Observable ' return ducts in other portions of t ❑Not Applicable j the building insulated >= R-6 for I diameter>= 3 inches and R-4.2 for<3 inches in diameter. j 403.3.2 !Ducts, air handlers and filter []Complies [FR13]1 boxes are sealed with :, ❑Does Not ;joints/seams compliant with ❑Not Observable International Mechanical Code or ❑Not Applicable International Residential Code, as applicable. 1= 403.3 ;Duct system in new buildings and a ❑Complies [FI32]1 additions are located in a ❑Does Not ;conditioned space in accordance ( ;❑Not Observable :with Sections R403.3.7 (1-2). P a '❑Not Applicable 403.3.8 ;Ducts are sized in accordance i " ❑Complies [FI33]1 I with ACCA Manual D and sections =❑Does Not R403.7-8. [ ? ;❑Not Observable ' f .'❑Not Applicable 403.3.5 Building cavities are not used as .❑Complies [FR15]3 ducts or plenums. - - ❑Does Not .,[]Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2, Medium Impact(Tier 2) 3 Low Impact (Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 5 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.3.7 Ducts declared to be within the I = ❑Complies [FR28]3 conditioned space are either 1) f:" 'tY ❑Does Not completely within the continuous !.. ❑Not Observable air barrier and within the building thermal envelope, 2) buried •❑Not Applicable within ceiling insulation in j accordance with Section �. . 'R403.3.6 and the air handler is i located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 i = ' cfm/100 square feet of i ' conditioned floor area served by ,the duct system, or 3)the ceiling insulation R-value installed ..'_ against and above the insulated r' _ :duct>=to the proposed ceiling insulation R-value, less the R- i value of the insulation on the HVAC piping conveying fluids ; R- R-' ;❑Complies above 105 9F or chilled fluids ;❑Does Not ` t. below 55 9F are insulated to ?R- 3 ;❑Not Observable j❑Not Applicable 403.4.1 Trotection of insulation on HVAC `s .-• `❑Complies [FR24]1 piping. i -❑Does Not :❑Not Observable '❑Not Applicable 463:5:3,. ;Hot water pipes are insulated to R- R- ;❑Complies ❑Does Not '❑Not Observable ❑Not Applicable 403.5 ;; Energy conservation measures R- R- ❑Complies [FR29]?' for SWH systems follow ElDoes Not ,guidelines in section R403.5.1-5. ❑Not Observable ❑Not Applicable '403.6. :Automatic or gravity dampers are; :;' ;❑Complies [FIZ19]?' installed on all outdoor air ❑Does Not intakes and exhausts. # _ .'❑Nat Observable :❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2. Medium Impact(Tier 2) 3 Low Impact (Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value . Complies? Comments/Assumptions & Req.ID 303.1... ,-:All installed insulation is labeled ''r--,' ❑Complies [IN13]? or the installed R-values i ❑Does Not provided. ;' ❑Not Observable ' ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a;, R- R- ;❑Complies See the Envelope Assemblies 402.2.5, ';mass wall with at least 1h of the ❑ Wood ❑ Wood ❑Does Not ;table for values. 402.2.6 ;wall insulation on the wall ;❑ Mass ;❑ Mass ;❑Not Observable ' [IN3]1 '.exterior, the exterior insulation requirement applies (FR10). ;❑ Steel ❑ Steel ❑Not Applicable 303.2 i Wall insulation is installed per =;: •'= ❑Complies [IN4]1 manufacturer's instructions. ; ❑Does Not '❑Not Observable { ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value. Complies? Comments/Assumptions & Req.ID 402.2.4 ;Attic access hatch and door R- R- ;❑Complies [FI3]1 ;insulation >_R-value of the ;❑Does Not adjacent assembly. i ;❑Not Observable ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ;❑Complies [FI17]1 :ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 :❑Complies [FI27]1 determine air leakage with ft2 ft2 i❑Does Not ;either: Rough-in test:Total leakage measured with a ;❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including ;the manufacturer's air handler enclosure if installed at time of ;test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 ;Duct tightness test result of<=4 cfm/100 I cfm/100 []Complies [FI4]1 cfm/100 ft2 across the system or ; ftz ft2 ❑Does Not <=3 cfm/100 ft2 without air ; handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated [ ❑Complies [FI24]1 by manufacturer at<=2% of 1 ❑Does Not design air flow. i ❑Not Observable "?:.. ❑Not Applicable 403.1:1 Programmable thermostats r ;_.; J; ❑Complies [Fl9]2 installed for control of primary i ❑Does Not `'heating and cooling systems and ;: initially set by manufacturer to ❑Not Observable ; code specifications. AINot Applicable 403.1:2" Heat pump thermostat installed ;::•..' '❑Complies [FI10]? "on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403-.5.1 Circulating service hot water = ❑Complies [FI11]z` `systems have automatic or i:' �❑Does Not accessible manual controls. _ :❑Not Observable 1, ;❑Not Applicable ❑Com lies 463:6.1 All mechanical ventilation system P [F125]z:• fans not part of tested and listed + []Does Not j HVAC equipment meet efficacy ❑Not Observable and air flow limits per Table ❑ R403.6.1. Not Applicable 463:2;_` 'Hot water boilers supplying heat :- >' . ;' .`'' :'_ `'` : :' ''- ❑Complies [FI26]? through one or two-pipe heating r ❑Does Not systems have outdoor setback - ❑Not Observable control to lower boiler water 1: ",. temperature based on outdoor :❑Not Applicable temperature. ' 111 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact (Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.5.1.1 :Heated water circulation systems ❑Complies [17I28]z have a circulation pump.The �': , `❑Does Not system return pipe is a dedicated r:: :• return pipe or a cold water supply'' _ ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are ; ;.; - 'not present. Controls for - circulating hot water system pumps start the pump with signal C' for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and , no demand for hot water exists. ' 403.5.1.2-:Electric heat trace systems I; ❑Complies [FI29.]? `- comply with IEEE 515.1 or UL "`` - ;:.; ❑ Does Not %515. Controls automatically ❑Not Observable adjust the energy input to the heat tracing to maintain the f.: :' ❑Not Applicable desired water temperature in the ( _ piping i, 403:5.2 Demand recirculation water '❑Complies f030]? ' • systems have controls that "' r ❑Does Not manage operation of the pump ;'• and limit the temperature of the �-• '.;- ❑Not Observable water entering the cold water >. ❑Not Applicable piping to <= 104°F. 4,03.5.4 Drain water heat recovery units " ❑Complies (. ',.. [FI31]z. have >= 40 percent efficiency if : _ _ ❑Does Not installed for equal flow or>=52 ❑Not Observable percent efficiency if installed for II unequal flow.Vertical drain water 1 ❑Not Applicable heat recovery units comply with IL, ; CSA B55.2 and tested and labeled in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat I recovery units are< 3 psi for individual units connected to one ; or two showers. Potable water- .,side pressure loss of drain water heat recovery units are < 2 psi -:for individual units connected to j three or more showers. f ' 404.1 ';90%or more of permanent ( _ ❑Complies [FI611 'fixtures have lamps with an k ❑Does Not ;efficacy >= 65 lumans/watt or F: have a total luminaire efficacy ❑Not Observable >= 45 lumens/watt. ❑Not Applicable 404.2 ;Detached one and two-family P, ❑Complies I [FI3511 !dwellings and townhouses where «. ❑Does Not ;the conditioned space is> 1,400 'sf comply with the requirements ❑Not Observable (, .-❑Not Applicable !of Appendix RA. �. 404.3 ;,One or two-family dwellings and !' : ❑Complies [F]36]1 ,townhouses with parking area t' , , :❑Does Not provided on the building site shall i -. `have a 208/240V 40-amp outlet I . ❑Not Observable ,for each dwelling unit or panel ❑Not Applicable capacity and conduit for the I ifuture installation of such an outlet. See section details. 11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. I•. '❑Does Not ,Dj ❑ Not Observable ;; , • ,�❑Not Applicable 401.3... Compliance certificate posted. * ❑Complies ❑Does Not :❑Not Observable ❑Not Applicable ' 3033 ,Manufacturer manuals for ❑Complies ( 4 .; � �, •. :�� ". •- .. [FI18]3 mechanical and water heating ( "" x,,, .;:.;`' ❑Does Not j systems have been provided. - ❑_ Not Observable_ C" ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 2135 Marlene Lane_REScheck_050223 Report date: 05/02/23 Data filename: Page 10 of10 2020 NYStretch 2018 iECC Energy Efficiency Certificate Above-Grade Wall 25.00 Below-Grade Wall 20.00 Floor 0.00 Ceiling / Roof 0.00 Ductwork (unconditioned spaces): s . . Window 0.27 0.40 Door 0.20 CoolingHeating & Heating System: Cooling System: Water Heater• Name• Date: Comments . _ ... .. _. _ __ ____ as F\ F1 O � D T7 APP OVED AS NOTED OCCUPANCY OR IDAM4.a 910 ELECTRICAL '?' B.P.# 156 USE IS UNIAWFUL INSPECTION P.EQU!RED Paul H Bosco FEE BY: WITHOUT CERTIFICAT NOTIFY BUILDING DEPARTMI�WTAT Architectural Drafter 631765-1802 8AM TO 4PM FOR'ME OF OCCUPANCY FOLLOWING INSPECTIONS: P-O.Box 2473 1. FOUNDATION-TWO REQUIRED l Acluebogue, NY 11931 FOR POURED CONCRETE 631,375.7374 2. ROUGH-FRAMING&PLUMBING pauldrafter.com 3. INSULATION M 9� '1"K� 4. FINAL-CONSTRUCTION MUST ALL PLUMB1037 BE COMPLETE FOR C.O. R'LINES N'EEb' TE�T W F 7 THE 12313T ORE COVif�& Additional ALL CONSTRUCTION SHALL MEET REQUIREMENTS OF THE CODES OF NEW Certification YORK STATE. NOT RESPONSIBLE FOR reviewed by DESIGN OR CONSTRUCTON ERRORS May Be Required. 00hdon r--nc Orin P.C. 1755 Sigsb�-,e Road ottituck, NY 11952 COMPLY WITH ALL CODES Or PLUMBER CER TIFICA T101V NEW YORK STATE &TOWN CODES ON LEAD CONTENTBEFoRt AS REQUIRED AND CONDITIONS OF CER TIFICA TE OF OCCUpA NC -----------�SOUTHOLD TONS BA SOLDER USED IN WA TER ----------- SOUTHOLD T , PLANNING BOARD SUPPLY SYSTEM CANTER '9 J4 7 P,Jul c()m 'UT""TOV' SOUTH OLD UTH' T OLD OINTi SO(UTHO OM TRUSTEES EXCEED 2110 OF I% L FA ---------- N.Y.S.DE S. co ---------- SO LD HPC SCH 5 200 50 40" F 125.00' —--—-- Property of: CtIRISTOP� ER 5INGLFTON 51tuate: SSv')k\ '7 # 2 135 Marlene Lane Vv " 1A Town of S-5outhold Christopher Sinqlet n Suffolk County, New Residence York ct, Area: I 8�37& 242 5. F:. (0.422 acre5) ADDRESs 2135 FAARLENE LANE 5CTM No. : 1000- 144-03- 12 t attituck, NY 11952 C\1 Town of Southold, NY 0 pizomcr mkw As Build Finishing Basement CONTRACTOR SQUI TIOLD TON�NLMNSRI D RAWI N GS LIST` I)PAWINO NAME Cover Page - Site Plan LLJ A--, Built Finishing Basement floor Plan = , — 1,c-'A 1,1. Plumbing Ri!Der and Section i 0 as noted finv5hinc3 Electric ment-7 13,15e Exr��tincj A5 Duilt C\j 0 ORAWNU N1 AMER PROPERTY 18,3 7 4=2 SF WIT#WD052313S ALLOWED 04-28-2023 N 2 0 0 3- 9' 10' 125.00' # 2135 MARLENE LANE PROPOSED COVERAGE Site Pisan on Survey by rlatkan Taft- Corwin III propo5ea 51te plan L�nr. Surveying 5cale: 1 :20 C3 1 .7127.20130 1 58; K'la!n Road Jome5port, NY 1 1947 Paul M Bosco Architectural Drafter P.O.Bax 24.73 777=• _ .�... ____ __.,_ ..__ _ _.._ 631.375.7874 i it 2, 10 floor Jout ( 16I O.C. pnuldrafterxom h!rah = 7- 1,� I ° II f 1=� M 4- o c Lin=nii5hed ! ; t`e iew tl4�y BATH ROOM !_ I� STORAGE ROOM � � Condon Eng'ineer`inq P.�. cIg hgt I m 2ni c r.2a' 'i 75� i �h�� c��a� -0 I I attitLck NY 11952 '7 2 F CRAWL SPACE ' <i ! 631.293.13 N %P close J.: I rip co @)Q �� I storage under ° - � � � I � ; rta�r• cage �,+_�s � 'p�; I 306 headroom m u5t ad just ` x � 1 ( to 0-8'i high minimum h t 01 8 PLAY ROOM I GI_411 i PROPFRT l'i��V'`,ER J— — — — c lci hgt rChristopher Sir c#Ietc �t ' 1 ' c(g hgt Residence exi5tin y 372 5F, 1 ( €- 1 I, - lf7 1 ADDRESS ' j BEDROOM 2135 MARLENE LANE clg hgt A03 I Mattituck, NY 11952 lj/VJl\ b/r? \•5 ( ,Y.ram.5 i 1*91*1 NOTES: 210G Town of Southold, NY 438 5E l ; Fire blocking shall be provided to cut off all concealed h9t draft openings (vertical and horizontal) and to form an PRi'IccT r,Aarr. I f effective fire barrier between basement and first floor. I As Build 71-511 f Eire blocking shall be provided in wood-frame a.'echanic Room Finishing Basement construction in the, following locations: cc� r^ access must be 20 r minutes fire-rated seif-closing In concealed spaces of stud walls and partitions, C01,irRWTuR r vulated {contractor verify in field) including furred spaces and parallel rows of studs R ... ors rc studs, s follows.. un tagge >d studs a f Ilow j S O,.AGE unl�n ahe<. T - . ' Vertical? at the cehn and floor levels < 1`V1~Cl W14lC FlOOM c �- clg hgt rrovide %° type "x" drywall board y g -- -.. ?p ryw Horizontally at intervals not exceeding 10 feet G`- ;" 4L^o>�e, and against framed will Si+t'3f1i7r.1)7'I.Ci`tit.ICr�S(;� At openings around vents, pipes. ducts. cables and ( " S AC f 2 ` � inside Mechanic Rohm wire", at ceiling and floor level. with an approved I 2x 10 floor Jo.,.�t (S) I G' o.c. .�_ � -� _ material to resist the free passage of flame and FiltnCVitid tinMr; . I hl h = 7 1 products of combustion. 9 2x4 ,tud, s m d Batt ;nsulation R-1 ..,.. - -... _.. _.:._. - F e 4� vuXUL Insulation t6 fill gaps - I III - - - - - - - - - - - � � 1 concreteb'^ -- ',;�ye� I"rE roc an con re e wails — OPTIONAL MATERIAL IAl ` s no ted why- -- - 9Ji (� — — electric tank t .: _�� _ --..-__.___ - ROXUL is a non-combustible and water repellent - Ih2" I I h t 6- foundation :;a':srlfii --------__.: g C'-10� I `fit _ _ __ _ sefni=rigid insulation batt that provides fire stopping � ' ` " . ` �••' :i .. • ; . _ •"�; �- °-� _arn:.•�ed ;:.,rn _ --I.oke. F>?��•^r �Cat'br�ri aril a..ou.atical insulation properties, i.� intended • I -- ric Iah} to be used in conjunction with a flri:sealant I �:�.`.J"oY�,;,7A ry•�€nr n.•r, ,`e.�e f,('tL'+ <?�. ^r" p prevent the - ssa f fire and !gym--- t�> prev pa ae o oke 1 ` BA-5E MENT UNFINIS1=1ED AREA 4 12 5: ; r� ' m EASEMENT I'INbME0 AFTA `J5,4 WIT# D9238S •-- - - - - bA`'JEMENT CRAWL 5r'ACE 36G c= f 04- -2023 iberglass composite 5 1Rockwel! manufacturer existing projection 44"x widthC" window well a5 built flniShec l BASEMENT floor plan - - kale: y4r► L:Lt C`T -.... RICAL.�YMB©L LEGEND E Three Way Switch--- .z, TJ/7 :.':D:rner Control fuplex Uutlet - P?t,li H Bosco i ! 15plit Wire Duplex Outlet ArchitecturalDrafter - - - -- --- - - - --- Ground Fault In,"erru ter r, _ _. —_ > 3 , p � ;� • :j P O ex 2473 ! ;Dedicated Outlet Aris.lebegue, NY 11931 E i' E 6b�tall Mounted rixture 1 {•' .375.7 74 _"---- I Keee;S ed Ceiling rixture, �k` 5TORf�GE ROOM 1 • � �.iiidr tter.car�i — . i Recessed Ceiling F�ixtuee Wet Area ... ..—._ ,� ,,,_. . ._ i the beam •� o;) s • Ier orative Fixture ° ' -- E Porcelan Mounted Ge€Img Fixture d BATH ROOM reviewed by i Porcelan Mounted Full Chan Condon En ineering, P.C. < < Vacuum Outlet I _ , CRAtNL SPACE 'I 755 Sigasee Fled Exhaust rail with (jght: - i �I — -� ,> , T :TV Gable Jack 1 , 6 : I �1 - I Thermostat f ...< ....., �` :)moke Detector' ,., Carbon Monoxide Detector J _ ....... .. _._ -., i �4R :� � R �. 1 � •' �0� NE 'Alarm co ,a Fluorescent tubes i I i I I I o ^ " d E f , , n �W 051 - 1 PLAY ROOM _ _ s ; I PROPERTY C,Gt?vFR Christopher Singleton Residence f r ADDRESS - -��- o 27 tAll.lhiF LANE attituc , NY 11952 BEDROOM Town at"Southold, DIY PROJI7(7:�A\SE • e ? ( Finishing Basement S ( ? £ CON-rRACT(IR • ! MECHAHIC ROOM sTORAGE € DRAtt NXI\A%f-.' : �. �r I tiE�f•i: An noted i ORA4t'TINd 2+1i AMER F" WIT V-ID �523BS i)r<nc�t 04-2 -2023 sr ree:T as built finished E3A5EMENT electric plan �£ scale: Y4►' = 1 '-a'1