Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50242-Z
Of sour Town of Southold * P.O. Box 1179 ,0 53095 Main Rd Ulm Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45732 Date: 11/03/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 6190 Great Peconic BE Blvd Laurel,NY 11948 Sec/Block/Lot: 128.-2-5 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 12/19/2023 Pursuant to which Building Permit No. 50242 and dated: 01/23/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to: Mary Hoeltzel Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50242 07/10/2024 PLUMBERS CERTIFICATION: 0Auto ize Signature TOWN OF SOUTHOLD o�suFFoc�.�oG BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50242 Date: 1/23/2024 Permission is hereby granted to: Hoeltzel, Mary 213 Orchard Way Wayne, PA 19087 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 6190 Great Peconic Bay Blvd, Laurel SCTM # 473889 Sec/Block/Lot# 128.-2-5 Pursuant to application dated 12/19/2023 and approved by the Building Inspector. To expire on 7/24/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 i: Building Inspector O��pF SO(/�yol h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �o sean:devlinl-town.south old.ny.us Southold,NY 1 1 97 1-0959 Q Cow T`I,��' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mary Hoeltzel Address: 6190 Great Peconic Bay Blvd city,Laurel st: NY zip: 11948 Building Permit* 50242 Section: 128 Block: 2 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunation License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan . Service 3 ph Hot Water GFCI Recpt .Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 17.01 kW-Roof Mounted PV Solar Energy System w/ (42) REC405PureBlack Module: (3) Tesla Solar Inverters 7.6kW, 125A Combiner Panel w/(3) 40A Breakers, Lineside Tapped in Generator Transfer Switch Solar Inspector Signature: �' Date: July 10, 2024 S.Devlin-Cert Electrical Compliance Form OF SOGTyO6 * * TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CHULKING [ ] FRAMING /STRAPPING [ FINAL� totte/ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] -FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: in (/ DATE O INSPECTOR OF SOUTyO� 502 �� TA4 TOWN O SOUTHOLD. BUILDING DEPT. 10ou ,�E'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ _] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE:RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: DATE 6 "INSPECTOR Fisher n ineering Services, P.C. 509 Sayville Blvd• Sayville-New York 11782 ( Phone:(631)7864419 February 9,2024 R ECEOVE Town of Southold J U N 2 7 2024 Post Installation Certification Subject: Engineer Statement for Solar Roof Installation Building Department Agoglia-Hoeltzel Residence- 6190 Peconic Bay Blvd, LauTVrM#Spf sd Permit No: 50242 Installation Date:2/2/2024 Inspection Date: 2/7/2024 To whom it may concern, The roof.mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the as-built plans and is certified by William G.Fisher,PE to be in compliance with the minimum requirements of the Town,the 2020 Residential Code of New York State,2018 International Residential Code(2018 IRC),Long Island Unified Solar Permit Imitative(LIUSPI),and National Electric Code 2017,and the provisions of ASCE 7-16. NE ;Sincerely; ` William G.Fisher,P.E. Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•inspections FIELD INSPECTION REPORT DATE COMMENTS Q � N FOUNDATION(IST) H Nam. -----------=------------------------ _ FOUNDATION(2ND) z 4 y ROUGH FRAMING& y PLUMBING 1 r INSULATION.PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS . o ( �l 0% -�j- e rn N O �z e b y o��gt1FF0(K�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y� h x Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.goov_ Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: ..S DEC 1 9 2023 Do Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an walla €ng ?e a4ltto@3lr Owner's Authorization form(Page 2)shalir be completed. Touai 6 Of SvWhold Date: I R( l S a3 OWNER(S)OF'PROPERTY: Name:Mary-Hoeltzel _. _ . .._- s7 #1000-128-2-5 Project Address.6190 Peconic Bay Blvd, Laurel,. NY 11948 Phone#:917-334-4111 Email:info nfo_@�Allockbuilders.com _ -"- _ -. . __ Mailing Address:6190 Peconic Bay-_Blvd,Laurel, NY 11948 CONTACT PERSON: Name: Tammy Lea/Sunation Solar Systems Mailing Address: 171.-Remington Blvd., Ronkonkoma,_NY 11779 Phone#:631-750-9454 x 3y Email:permitting@sunation.com DESIGN PROFESSIONAL INFORMATION: Name:William Fisher Mailing Address:509 Sayville Blvd, Sayville, NY 11782 Phone#:631-786-4419 Imail:.bill@,f,isher-nv.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:_p 9@ erin sunation.com - - . _.mitt--. - DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 51.0 6m.nb Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes WNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. ❑.Check Box After-Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant.to.the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the,construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on,premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A.misdemeanor pursuant to Section 210.45 of the New York State Penal.Law. Application Submitted By(print name)- Scott Maskin BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file,therewith. Sworn before mee this /5-K-�day of 11e CDW lz✓ ,20 No#dWRyftblic, State of New York Registration #01V15068399 Qualified in Suffolk Cnu,Ity My Commission Expires ��,. 28, 20a6 PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Mary Hoeltzel residing at 6190 Peconic Bay Blvd Laurel do hereby authorize Scott Maskin to apply on my behalf to the Town of S uthold ilding Department for approval as described herein. -a-& -,)-6 23 Owner's ignat r I Date M q fai fq0��-�2�c.� Print wner's Name 2 D E C E ll I �s���11fFOl,��o BUILDING DEPARTM Ele al n �{�O. G� TOWN OF SOUTHOLD o Town Hall Annex- 54375 Mai INSouthold, New YorkW,1-195.uti oid Telephone l rogerrO-southoldtownnv6a v- se ndOsou ho dtO ownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Sunation Solar Systems, Inc. Electrician's Name: Scott Maskin License No.: 33412-ME Elec. email:closeout@sunation.com Elec. Phone No: 631-750-9454 ❑✓ I request an email copy of Certificate of Compliance Elec, Address.: 171 Remington Blvd., Ronkonkoma, NY 11779 JOB SITE INFORMATION (All Information Required) Name: MAr.1 A p l:n - HOC Itt c 1 Address: Qqo C on:C ow Laaml y I I Q yQ Cross Street: Phone No.: Cqf S" - /}1 BIdg.Permit#: J50 2L/Z email: i Arc Mc►1I oCk ba*Ucn Tax Map District: 1000 Section: IZI Block: Lot: BRIEF-DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): S�oIQ�. Square Footage. Circle All That Apply: Is job ready for inspection?: YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: YES❑NO Issued On Temp Information: (All information required) Service Size❑1 Ph 73 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 72 n H Frame Pole Work done on Service? MY N Additional Information:. PAYMENT DUE WITH APPLICATION rtc I \WQ ,r E C E E nn r... V , BUILDING DEPARTMElect' alInsp" ' �O� c0� TOWN OF SOUTHOLD o `. Town Hall Annex- 54375 Mair ugWl- -MOL)(411,79 Southold, New York r9i9L; ,o.; ® a ;Sr Telephone (631) 765-1802- FAX (631) 765-9502 1 rogerr(a southoldtownny.ctov seand ,)southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Sunation Solar Systems, Inc. Electrician's Name: Scott Maskin License No.: 33412-ME Elec. email:closeout@sunation.com Elec. Phone No: 631-750-9454 ❑✓ 1 request'an email copy of Certificate of Compliance Elec. Address.: 171 Remington Blvd., Ronkonkoma, NY 11779 JOB SITE INFORMATION (All Information Required) Name: 14M.1 p l : w - HOC I tZ c Address: &M QL on t&-ir+cl `I 1 I Q yQ Cross Street: Phone No.: q} _ Bldg.Permi Fj0 ISM MIS email: ;nil4 katl oCri�o11c13 rC Tax Map District: 1000 Sec ion: I Z Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 5ola� Square Footage: Circle All That Apply: Is job ready for inspection?: 0✓ YES❑ NO Rough In ❑ Final Do you need a Temp Certificate?: 0 YES❑NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground[]Overhead #Underground Laterals D 1 2 R H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION 346 RJ uu fh PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Waver Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments v"owc A workers! CERTIFICATE OF INSURANCE COVERAGE Compensation Board .NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured SUNATION SOLAR SYSTEMS 631-750-9454 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"1 a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/01/2022 to 09/30/2024 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. AfDate Signed 9/26/2023 By wid (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 413,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 1111111�1 III I III DB 120.1 (12-21) Additional Instructions for Form D13-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law.The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage(Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier. This Certificate is issued as a matter of information only and confers no rights upon the certificate holder. This Certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first,two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (12-21)Reverse MMO .4® CERTIFICATE OF LIABILITY INSURANCE DATE z(M 02� THIS CERTIFICATE 15 ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE JSI UING INSURER(S),'AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT AME CT The Horton Group PHONE FAX 10320 Orland Parkway .708-845-3000 AIC No): Orland Park IL 60467 AD REss: Certificates thehorton rou .com INSURE S AFFORDING COVERAGE NAIC0 INSURER A:Evanston Insurance Company 35378 INSURED SUNASOL-01 INSURERB:The Continental Insurance Company 35289 SUNation Solar Systems,Inc. 171 Remington Blvd_ INSURERC:Axis Surplus Insurance Co. 26620 Ronkonkoma NY 11779 INSURER 0:Travelers Property&Casualty Company of America 25674 INSURER E:Bums&Wilcox Ltd. I INSURER F: I COVERAGES CERTIFICATE NUMBER:703220016 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY±REQUIREMENT.TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HE iEIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS.OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOLSUBR pOLICYNUMBER MMOIUDD EFF MOMIUOY EXP I LIMITS LTR A X COMMERCIAL GENERAL LIABILITY Y Y 121 CTR 0212775-00 2/11/2023 2/11/2024 EACH!OCCURRENCE S 1,000,000 DAMAGE TO RENTED CLAIMS-MADE OCCUR ! PREMISES Es oaurmnce S 300,000 i MED EXP(Any one person) S 10,000 PERSONAL BADV INJURY S 1,000,000 r GEn AGGREGATE LIMIT APPLIES PEP: { GENERAL AGGREGATE S2,000,000 t POLICY[fl JECTT LOC PRODUCTS-COMP/OP AGG '$2,000 000 OTHER: i j s B AUTOMOBILE LIABILITY Y Y 7018308202 2/11/2023 2/11/2024 COMBINED SINGLE LIMIT S1,000,000 Ea acddent X ANY AUTO BODILY INJURY(Per person) S OWNED X SCHEDULED' BODILY INJURY(Per ac6dant) S AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE S AUTOS ONLY AUTOS ONLY Per ecddent I I S C X UMBRELLA LIAB X OCCUR i Y Y P-001-000795195-02 2/11/2023 2/11/2024 EACH OCCURRENCE S3,000,000 EXCESS LIAB CLAIMSAWE AGGREGATE $3.000.000 DEO I I RETENTIONS I S WORKERS COMPENSATION PER OTH- AND EMPLOYER5LUIBILITY YIN STATUTE ER. ANYPROPRIETOR/PARTNERIEXECUTIVE E.L.EACH ACCIDENT S OFFICERIMEMBEREXCLUE NIA t (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE S It os,describe under DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT $ D Builders Risk Y Y QT-630-2T010874-TIL-23 2111/2023 2111/2024 Limit; 500,000 E Professional/PollutionLiability 1000704865 2/11/2023 2/11/2024 LImlti $1,000.000 D Leased/RentedEquipment QT-630-2T010874-TIL-23 2/11/2023 2/11/2024 Umtj $250,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101.Additional Remarks Schedule,may be attached if more apace Ia required) Additional Named Insureds:SUNation,Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liabilit5r Automobile and Pollution Llability coverage when required by written contract Waiver of subrogation applies to general liability,Automobile and Pollution liabi ity in favor of the stated additional insureds when required by written contract.Excess follows form. Town of Southold is included as an additional insured as required by Written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION I I SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 `- 2�� ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD 11 N Y S 1 F PO Box 66699,Albany,NY 12206 New York State Insurance-Fund I nySlf.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE """""" 753118816 0• 0 GCG RISK MANAGEMENT INC AN NFP COMPANY 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 0� SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 598021 01101/2023 TO 01/01/2024 12/08/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY.AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND /"" 4 DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 959308854 111311111110000000010001103012211I�ul�ll�lu Form WC-CERT-NOPRINT Version 3(08/2912019)[WC Policy-21606702] U-26.3 64 [00000000000130301221][ODOI-000021606702][##Z][16o3o-19][Ce t.Noa-CERT_1][01-00001] Suffolk County Dept.of Labor,Licensing&Consumer Affairs t HOME IMPROVEMENT LICENSE s� Name I SCOTT A MASKIN 4 i r .. Business Name • i s certifies that the firer is duly licensed SUNATION SOLAR SYSTEMS INC } :he County of sufolk License Number:H44104 Rosalie Drago Issued: 03/06/2008 Commissioner Expires: 3/1/2024 S ° 1 I 1 ,t t i I� f Suffolk County Dept. of Labor, Licensing & Consumer Affairs MASTER ELECTRICAL LICENSE Name SCOTT A MASKI N ... Business Name This certifies that the SUNATION SOLAR SYSTEMS INC bearer is duly licensed License Number ME-33412 by the County of suffolk Issued: 06/24/2003 R Drag.- Expires: 06/01/2025 Commissioner �F OF rNFly n2N �P \\or• v.,f��� 0 I SERVICE t I D/C Series String(typ.) —a PSEG-G U01,Meta, ; Accou�lP-d65dO6d9a] - � INVERTER M Me1erP.9essssn �F` '� _ rzarzdov OA a.0746�9 TESIA 1538000-45-A INVERTER 11 F - � UNGROUNDED WITH , '--1 Module J-Box(ryp.(I INTEGRAL DC ISOLATOR SWITCH 120240 VAC.1-PHASE MAX 32 AMP O SUPPLY-SIDE i FISHER ENGINEERING, �PV Module(ryp.) I 1, CONNECTON EXISTING SERVICES,P.C. EGO Altactled To Ballast Tray(ryp.) 1 GENERATOR 509 Sayville Boulevard 0 I Sayville,New York,11782 • r I Licensee No.074659 / I (631)-786-4419 • • • • ? 125A 3 MAIN J I MAIN Bill@Fisher-NY.com CONDUIT AND CONDUCTOR SCHEDULE INVERTER#1-DO STRING#1 } MAIN 1 I i _° SUNe�`��®N TAG CONDUCTOR CONDUIT RUN INVERTER 01-DC STRING 12 INVERTER#1-DC STRING#3 DC Relay TYPE GAUGE QUANTITY TYPE SIZE LENGTH AC INPUT OUTPUT .2P40A.•' * �- 1 V Wife 10 18 N/A WA 60, INVERTER#2.DC STRING#a—J -ap�pAu SUNation Solar Systems GC 10 2 N/A N/A 60' j G \ -� - I 171 Remington Blvd. INVERTER#2-DCSTRING#5—� I Ronkonkoma,New York 11779 2 HWN-2 8 9 PVC SCH.80 1.5" 10' SOLAR (631)-750-9454 INVERTER#2-DC STRING#6— INVERTER G GC 10 3 PVC SCH.80 1.5" 10' I l 3 HWN-2 1 3 PVCSCH.�112,1�11 �10 ITESIA1538000-45-AINVERTER02 PaNe� 7LG G NYSERDA 4 GC INVERTER#3-DC STRING#7 I PHOTOVOLTAIC AUTOMATIC 6 1 PVC SCH. I j ! I I I UNGROUNDED WITH I TRANSFER MAIN b1AIN INSTALLER A0155 �` INTEGRAL DC ISOLATOR SWITCH SERVICE INVERTER#3-DC STRING#8 SERVICE 1 1 1 I 120240 VAC.1-PHASE SWITCH PANEL PANEL NUMBER INVERTER#3-DC STRINGC� I I i � i MA%32 AMP II 4 I M I i JOB NUMBER j I BUILDING O I I I GROUNDING GROUN No DING 23477 / - II ELECTRODE ELECTRODE �'aT • I t II II i I • DC AC I INPUT OUTPUT Olo L J J SOLAR INVERTER T TESLA 153800045-A INVERTER 93 I - N ' UNGROUNDED WITHINTEGRAL DC ISOLATOR SWITCH LJ \ 120240 VAC,1-PHASE I M MAX32AMP \ 0 z0 cts N > C . . . ® O N a Maximum AC _ Z aD= 75 String# PV Module Qty. Inverter Operating Current I w = 0 U 1 DC AC N m 1 REC405AA 5 INPUT OUTPUT 2 REC405AA 5 Tesla Solar Inverter#1 32.OA — — — G SOLAR 0•c Cz INVERTER _ V Q 3 REC405AA 4 4 REC405AA 5 rL 0 rn 5 - REC405AA 5 Tesla Solar Inverter#2 32.OA 6 REC405AA 4 7 REC405AA 5 8 REC405AA 5 Tesla Solar Inverter#3 32.OA 9 REC405AA 4 Maximum AC Operating Current(Total) 96.OA E1 = 1 ONE—LINE DIAGRAM Fisher Engineering Services, P.C. 509 Sayville Blvd • Sayville •New York 11782 Phone: (631)786-4419 February 9, 2024 Town of Southold Post Installation Certification Subject: Engineer Statement for Solar Roof Installation Agoglia-Hoeltzel Residence 6190 Peconic Bay Blvd, Laurel, NY 11948 Permit No: 50242 Installation Date:2/2/2024 Inspection Date: 2/7/2024 To whom it may concern, The roof mounted photovoltaic'system at the above referenced residence has been generally observed to be installed properly in accordance with the as-built plans and is certified by William G.Fisher,PE to be in compliance with the minimum requirements of the Town, the 2020 Residential Code of New York State, 2018 International Residential Code(2018 IRC),Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2017,and the provisions of ASCE 7-16. NE�y YD Sincerely, William G. Fisher, P.E. Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections PLAN KEY ®-I/T METER 6Q QSE RVICRVICE� CONNECT PROPOSED RESIDENTIAL PV1-0 � COVER SHEET -SUPPLY SIDID E CONNECTION A11-1 PARTIAL ROOF PLAN 1 AUTOMATIC TRANSFER SWITCH PHOTOVOLTAIC SYSTEM Al-4 ROOF ACCESS PLAN El-GAS METER S1-1 STRUCTURE ®'MAIN SERVCEPANEL B PAN -suELESS 171 RE IN SOLAR SYSTEMS INSTERDA ALLER 4355 E1-1 ONE-LINE DIAGRAM 171 REMINGTON BOULEVARD INSTALLER -WIRELESS ROUTER E2-1 PV LABELS ®.INVERTER RONKONKOMA,NEW YORK 11779 NUMBER G1-1 PV PHOTOS ©-ENPHASE 10 COMBINER ©-PANEL PHOTOVOLTAIC Agog lia-Hoeltzel Residence -ELECTRIC VEHICLE CHARGER 6190 Peconic Bay Boulevard, Laurel, NY 11948 ®-ENPHASE ENVOY -SENSE CONSUMPTION MONITOR AC DISCONNECT Drawn By: C. Blank - 12/13/23 ®- •\ -TESLA GATEWAY ®-TESLA POWERWALL /.' OF A/ Fly ENPMASEIOSYSTEMCONTROLLER FISHER ENGINEERING SERVICES, P.C. Q-ENPHASE IO LOAD CONTROLLER O ®-ENPHASE 1010 BATTERY Q 509 Sayville Boulevard 3 ®-ENPHASE K)3BATTERY j� Sayville, New York, 11782 //^ i Licensee No. 074659 ®-GENERATION PANEL p -� / En-BACKED UP LOADS CENTER W �� �� ' \� (631)-786-4419 u74o-�', V Bill@Fisher-NY.com O-VENT PIPE N -EXTERIOR LOCATION z 18'-VENi1lATgN - -1ST FLOOR LOCATION T Building Review Note -BASEMENT LOCATION o • -GARAGE LOCATION = Town building examiner has received the enclosed document for minimum acceptable o „\ ` plan submittal requirements of the town as specified in the building and/or Residential Code of the State of New York. This review does not guarantee compliance with that code. that responsibility i guaranteed s a anteed under the e P sal an i LL _ Y 9 d signature of the New York State licensed design professional of record. That seal and signature has been i 7 i r interpreted as an attestation that,to the best of the licensee's belief and information PROPOSED PV SYSTEM \v, 71 the work in this document is: _� • Accurate T ,�, 4}I Conforms with governing codes applicable at the time of submission ^Ts"' M P ! `+^PROPOSED PV MODULES • Conforms with reasonable standards of practice and with view to the Module Type/Qty: (42) REC405 Pure Black Pa,NY NY safeguarding of life,health,property and public welfare is the responsibility of the Module Dimension: 71.69"x 40"x 1.18" E"' APPROVED AS NOTED licensee. ® Module Weight!PSF: 45 Ibs/2.3 PSF Structural Statement DAfi_- 3 B.P.# Micro Inverter: (3)Tesla Solar Inverter 7.6kW P • The existing structure is adequate to support the new loads imposed by the FEE / BY. photovoltaic module system including uplift and shear. The existing rafter sizes System DC Rating: 17.01 kW NOTIFY BUILDING DEPARTMENT AT and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. Estimated AC Production: 17,912 kWh/yr 631-765-1802 8AM TO 4PIV FOR THE PV Notes Production Source: Aurora FOLLOWING INSPECTIONS: 1. This PV system has been designed to meet all current and applicable fire 1. FOUNDATION-TWO R►-,D; -D prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be FOR POURED CO-) GREi provided where necessary. An in depth description of each applicable code 2 ROUGH-FRAtV1fVG&F'L ; reference and exception for any codes is depicted on the PV-1 plate of this drawing package. S. INSULATION 2. Roof shall have no more than a single layer of roof covering in addition to the 4. FINAL-CONSTRUCTION MUST solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more BE COMPLETE FOR C.O. than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf ALL CONSTRUCTION SHALL MEET THE 5. Any plumbing vents are not to be cut or covered for solar equipment installation. REQUIREMENTS OF THE CODES OF NEW Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN inspection. SCALE:N.T.S. YORK STATE NOT �pppyRR��'ErESSPP1ON��-�SIBB��LLEEp FOR This PV system has been designed to meet the minimum design standard for building MIM 1 fl 1-1L� I�VLJC�7 OF and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. NEW YORK STATE &TOWN CODES PV1 AS REQUIRED AND CON ITIONS OF O COVER PAGE JOB# 23477 JEC ZBA OCCUPANCY Off, PLANNINGBOARD USE IS UNLAWFUL ELECTRICAL REVISION # N/A TRUSTEES WITHOUT CERTIFICAT INSPECTION REQUMM SUNATION REVISED BY N/A OF OCCUPANCY OF NFl1, O P n �Oo N0.074659 STRING #1 STRING #2 STRING #3 (�(/ INVERTER 1 INVERTER 1 INVERTER 1 FISHER ENGINEERING „y• RIDGE SERVICES,P.C. 509 Sayville Boulevard Sayville,New York,11782 RIDGE CAPPING Licensee No.074659 �— (631)-786-4419 — � (NP') Bill@Fisher-NY.com c PFV �U "° SL44ATION / "`2 EVER` ----r- � SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 i NYSERDA INSTALLER 4-1 3 5 5 NUMBER 23'-5y2" I JOB NUMBER 23477 C O) } Z r) Z m co PHOTOVOLTAIC MODULE -0 'm IN (TYP.) Ir Y O N N m STRING #7 z =$' ci GUTTER -STRING #5 - STRING #6 ROOF AREA m m ro m INVERTER 3 INVERTER 2 INVERTER 2 O C7 STRING #4 STRING #9 STRING #8 a INVERTER 2 INVERTER 3 INVERTER 3 Co Roof# Roof Description Modules Azimuth Tilt Pitch Attachment Spacing: Portrait Attachment Spacing: Landscape 3/16" = 1'-0" Interior Edge Corner Interior Edge Corner 1 Southwest Roof 42 239' 450 12/12 48" 32" 16" 64" 48" 48" Al 1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS �� nF /V jNY) R324.6 Roof access and pathways. Roof access, pathways and �Q \\� r setback requirements shall be provided in accordance with Sections h 0 R324.61 through R324.6.2.1. Access and minimum spacing shall be ? P - required to provide emergency access to the roof,to provide pathways to specific areas of the roof, provide for smoke ventilation opportunity , areas and to provide emergency egress from the roof. ��o tiO 07 Exceptions: 1. Detached, nonhabitable structures, including but not limited to FISHER ENGINEERING detached garages, parking shade structures, carports, solar SERVICES,P.C. trellises and similar structures, shall not be required to provide 509 Sayville BoulevardSayville,New York,11762 roof access. 74659 2. Roof access, pathways and setbacks need to be provided Licensee No.(631)-786-4419419 where the building official has determined that rooftop Bill@Fisher-NY.com operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two units vertical in 12 units horizontal(17-percent slope)or less SUNATION�l [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SJUNation Solar Systems roof panes from lowest roof edge to ridge and not less than 36 inches 171 Remington Blvd. (914 mm)wide, shall be provided on all buildings. Not fewer than one \ j Ronkonkoma,New York 11779 (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, a pathway not less than 36 inches (914 mm) wide shall be provided from the lowest roof edge - NYSEROA 43 5 5 to the ridge on thee same roof plane as the photovoltaic array, on an INSTALLER adjacent roof plane, or straddling the same and adjacent roof planes. ; — �__ NUMBER Pathways shall be over areas capable of supporting fire fighters JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit, or mechanical equipment. 'a 23477 Pathways on opposing roof slopes shall not be located along the same w plane as the truss, rafter, or other such framing system that supports Awes the pathway. N0°° 0 Exception: W \ i ro 1. Access pathways shall not be required on roof slopes containing � o, Z - - photovoltaic modules, panels, or an array where the opposing ,e°-vENTi�ATioN } or adjacent roof slope is an access roof. L Z co w \ r / Z _ a Access Roof-A roof surface that: o v T co x H 2 m r i 1. Can be accessed from the ground by the fire service. Q ` \ � � N °� m 2. Is capable of providing fire service access to the ridge or peak o O �/ �" of an opposing or adjacent roof surface that contains LL �, photovoltaic modules, panels,or an array. Z 0 m° 3. Is relatively free of vents,skylights,conduits,mechanical �,% i ' y% ;' / w m m N om 3 equipment and other such obstructions. a o C 4. Does not contain photovoltaic modules, panels or an array, or is s o T (G) a single ridge roof where the maximum edge to edge width of 0 ATS =_ the photovoltaic panel system does not exceed 33 percent of MSP MSP (a2)PROPOSED PV MODULES o PPV NV NV NV the ridge length. m - (EX7) ®[NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be (EXT) located less than 18 inches(457 mm)from a horizontal ridge. [ 324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches (914 mm)wide shall be provided to the emergency escape and rescue opening. N.T.S. A1 =4 ROOF ACCESS PLAN 46 • y �� OF NFL Typical Attachment Method RIDGE Fs I NN\- / PHOTOVOLTAIC SNAP'N'RACK ULTRA RAIL 23'-5.5" �L-FOOT AND RAIL ASSEMBLY FISHER ENGINEERING MODULE 509 SERVISayvlCES, P.C. rd \ ® Sayville,New York,11782 3/4" MODULE SPACING Licensee No.074659(631)-786-4419 BETWEEN ROWS AND Bill@Fisher-NY.com COLUMNS(TYP.) (2)S.S.304 5.OMM X 60MM \ WOOD SCREW FASTENER I d SUN/�TION \\ \ \ RT-MINI ROOF RAIL ATTACHMENT I SUNation Solar Systems MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 RAFTER (1)LAYER ASPHALT (631)-750-9454 2" X 1t)" � 16" O.C. SHINGLE(TYP.) � INNYSERDA \ / NUMBER i/ JOB NUMBER PLYWOOD DECKING 23477 )TYP SOFFIT ( . WOOD FRAMING—� EXTERIOR WALL (TYP.) ATTACHMENT TYPE APPLIED TO-ROOF"TYP" 15'-2" w ROOF SECTION (TYP.) SCALE: N.T.S. } � Z N C: M C � T � Z N SOLAR MODULE FRAME 0 NOTE:3/4"SPACING 0 r T BETWEEN MODULE ROWS Q AND COLUMNS. HEIGHT ADJUSTABLE 0LL m Roof# Rafter Size/Spacing Max Span Material Layers Sheathing ENDCCLAMPP) Z O 0 U 1 2" x 10" /16" O.C. 15'-2" Com osite Shingles (TYP.) LU = m p 9 1 Plywood t m mvo SNAP'N'RACK6.0" ULTRA RAILOm�i (1YP.) Q ECZ HEIGHT OFF OF 0 Q ROOFSURFACE (3) (T MINI2 O Typical Module mP' 0' YP PEST WRAP CUT r Side Profile AWAYFOR cfl CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE SEISMIC DESIGN WINTER DESIGN ICE BARRIER GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE MEAN ANNUAL LOAD SPEED(MPH.) EFFECTS SPECIAL WIND ZONE ZONE UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX REQUIRED TEMPERATURE 20 PSF 140 B YES 2 8 SEVERE 3'.0.1 MODiEAVY ERRATE TO 15 DEG N/A SEE PLANS [i I =I EXAMINER 599 51 STRUCTURE �F OF /NV 120/240v �Q\�o rn G.Fs��O UTILITv SERVICE y' D/C Series String(typ.) Emu,o n . . - ■ Me PSEG.LI UOYIy l,, M Attnunl a 4050 903 Meta e-966969. INVERTER lmrzaov �Ay0. `�9 °C TESLA 1538000-45-A INVERTER#1 0746 F., - UNGROUNDED WITH S Module J-Box(typ.) INTEGRAL DC ISOLATOR SWITCH 120/240 VAC.1-PHASE MAX 32 AMP i SUPPLYSIDE FISHER ENGINEERING PV Module(typ.) O CONNECTION EXISTING SERVICES,P.C. EGC Attached To Ballast Tray.(typ j GENERATOR 509 Sayville Boulevard 0 Sayville,New York,11782 � Licensee No.074659 (631)-786-4419 • • 2 125A 1 3 MAIN MAIN Bill@Fisher-NY.com INVERTER#1-DC STRING 2 MAIN J CONDUIT AND CONDUCTOR SCHEDULE SUNATION INVERTER#1-DC STRING#2— TAG CONDUCTOR CONDUIT RUN • �� Au� � 'v INVERTER#1-DC STRING#3 DC AC TYPE GAUGE QUANTITY TYPE SIZE LENGTH INPUT OUTPUT 2P4oA 1 V Wire 10 18 N/A N/A 60' _ ~,� SUNation Solar Systems INVERTER#2-DC STRING#4 G w ., GC 10 2 N/A W 171 Remington Blvd. 1 SOLARA 0' INVERTER#z-DC STRING#s Ronkonkoma,New York 11779 2 HWN-2 8 9 PVC SCH.80 1.5" 10' SOLAR GC 10 3 PVC SCH.80 15. 10' INVERTER#2-DC STRING#6— INVERTER G (631)-750-9454 3 HWN-2 1 3 PVC SCH.80 2.50" 10' I TESLA 1538000.45-A INVERTER;p2 PgNEL G G G NYSERDA INVERTER#3-DC STRING#7 UNGROUNDED WITH PNDrovoLTglc AUTOMATIC 3 5 5 F 4 GC 6 1 PVC SCH.80 2.50" 10' TRANSFER SERVICE '�'" INSTALLER INVERTER#3-DC STRING#8—� INTEGRAL DC ISOLATOR SWITCH SERVICE 120/240 VAC,1-PHASE SWITCH PANEL PANEL NUMBER INVERTER s3-DC STRING#9 MAX 32 AMP I 4 JOB NUMBER EGC 1 O BUILDING BUILDING GROUNDING GROUNDING 23477 t r r r ELECTRODE ELECTRODE • DC AC WPUT OUTPUT 00 SOLAR T INVERTER T TESLA 153800045-A INVERTER#3 UNGROUNDED WITH z co INTEGRAL DC ISOLATOR SWITCH N N 120/240 VAC,1-PHASE U MAX 32 AMP I U � r F © Z O N (6 � J 0 Q 1 - � 1 • I (D j (6 O N a) m Maximum AC • • z m String# PV Module Qty. Inverter Operating Current uw m U = AC F 1 1 REC405AA 5 'NPR OUTPUT o co 2 REC405AA 5 Tesla Solar Inverter#1 32.OA - -- — G Q INVERTER 0 Q 3 REC405AA 4 11 4 REC405AA 5 CD rn 5 REC405AA 5 Tesla Solar Inverter#2 32.OA 6 REC405AA 4 i 7 REC405AA 5 8 REC405AA 5 Tesla Solar Inverter#3 32.OA 9 REC405AA 4 E1 = 1 Maximum AC Operating Current(Total) 96.OA ONE-LINE DIAGRAM OF LABEL LOCATION: Service LABEL LOCATION: �P`� M GN'� O AR • • • CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN DISCONNECTPOWER SOURCE =0 CEILINGS/FLOORS OR MORE THAN 10'. PANEL SPLICEICOMBINERS: 1 AT ANY COMBINER BOX IF USED 1 of NEC 2017 705.10 NEC 2017 690.31(G)(3)/NEC 2017 690.33(E)(2) q ti0•GJ46S9 Second DisconnectA WARNING OFFS a�F Located next to Meter • an FISHER ENGINEERING SERVICES,P.C. DO 509 Sayville Boulevard NOT DISCONNECT Sayville,New York,11782 NDERLOAD Licensee No.074659 LABEL LOCATION: (631)-786-44196111@Fisher-NY.com This building is equipped with an MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN SERVICE SUNATION DISCONNECT PANEL AND UTILITY METER Interconnected Electric Power • • • • LABEL LOCATION: Production Source NEC 2017 705.10 SUNation Solar Systems MAXIMUM AC • • • 171 Remington Blvd. •• AC DISCONNECTING MEANS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE Ronkonkoma,New York 11779 OPERATING AND CURRENT VALUES ON DISCONNECT LABEL. Source Type (631)-750-9454 NOMINAL Solar Photovoltaic NEC 2017 690.54/NEC 2017 690.13(B) Disconnect is Located Interior NYSERDA 4355 Basement_ Garage-_ Extenor_ INSTALLER -# -- Front:_ Rear._ LH Side: NUMBER WARNING* RHSide_ Omer Location. JOB NUMBER Service Disconnect SUNation Solar Systems �, ____• ww.sun0-9454 23477 "�""'""'"._ �ww.sunahon.ccm • ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS Primary ServiceDisconnect TERMINALS ON BOTH THE LINE AND Located _ Service Panel LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE PHOTOVOLTAIC SYSTEM WHENEVER THEV ARE EXPOED TO SUNJGFR INVERTER/AC DISCONNECT/DC DISCONNECT: 1 AT EACH OF THE OD EQUIPPED . NOTED LOCATIONS SHUTDOWN NEC 2017 690.56(C)(1)(a) r PV SYSTEM DC DISCONNECT } LABEL LOCATION: Z Cr) SOLAR SYSTEM EQUIPPED OPERATING CURRENT DC DISCONNECT: 1 AT EACH INTEGRATED DC DISCONNECT. COMPLETE VOLTAGE co T AND CURRENT VALUES ON DC DISCONNECT LABEL. WITH RAPID SHUTDOWN OZ N OPERATING • VOLTAGE -0 (D MAXIMUM SYSTEM VOLTAGENEC 2017 690.53/NEC 2017 690.13(B) TURN RAPID SHUTDOWN f' N SWITCH TO THESHORT CIRCUIT CURRENT Y "OFF'POSM(:)N TO I arss Cz C: SHUTDOWN PV SYSTEM cc Cz AND REDUCE THE LL m SHOCK HAZARD Z p -- N ARRAY W 0 m WARNING WARNINGmED ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD Q C: CU CU a� THE DC CONDUCTORS OF THE DC CONDUCTORS OF � THIS PHOTOVOLTAIC SYSTEM THIS PHOTOVOLTAIC SYSTEM O ARE UNGROUNDED AND ARE UNGROUNDED AND Cn MAY BE ENERGIZED MAY BE ENERGIZED cTp E2ml PV LABELS �F NFL r jQ•\\�o m G.,r�� �O `A 3 P T NOW FISHER ENGINEERING SERVICES,P.C. 509 Sayville Boulevard Sayville,New York,11782 Licensee No.074659 {� r- (631)-786-4419 Bill@Fisher-NY.com SUNNTION SUNation Solar Systems 171 Remington Blvd. Ronkonkoma.New York 1 1779 (631)-750-9454 SER INSTALLLEE R 4-155 IN NUMBER r JOB NUMBER ARRAY LOCATION(S) ARRAY LOCATION(S) AT 23477 SATELLITE IMAGE VIA GROUND VIA ROOF 00 pr D E L T A � �d � Z M N N O c15 N cc Co o _ CY) i �li j CO SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP 1G1 = 1 ---- — - —'— PV PHOTOS J v,. Fisher Engineering Services, P.C. 509 Sayville Blvd -.Sayville -New York 11782 Phone: (631) 786-4419 December 14, 2023 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Agoglia&'Hoelzel Residence- 6190 Peconic Bay Boulevard, Laurel,NY 11948 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system (photovoltaic system)-and its installation.satisfies the structural roof framing design load requirements of the 2020- Residential Code of New York State(2020 RCNYS), Long Island Unified Solar Permit Initiative (LIUSPI), 2017 National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting,the rails shall be securely,anchored to the roof utilizing lag screws that have been designed for wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x10" on 16" c.c., with an actual span of 15'-2", with plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, NEw ro William G. Fisher, P.E. Licensed Professional Engineer `� Q i Architectural Design-Residential-Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight-Expediting-Inspections S SOLAR'S MOST TRUSTED REC �z 1.., kX S s � r l t % 44 t` .a h x} S poau r EXPERIENCE PEE 400wp 25 YEAR PROTRUST T / 20.E F T2 WARRAN�Y� ti LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE REC PRODUCT 5PECIFICATI brN5 0 SOLAR'S MOST TRUSTED � 1821±2.5 D7.7±0.1] I 28[1.11 901[35.51 460[18.11 QCERTIFICATIONS IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) ..........................................._................................................................................................................................... + ISO14001:2004,ISO 9001:2015, I OHSATS 18001:2007,EC 62941 \ 1100[43.3] OVE .EI� Intertek 6.0±0.2 .� [0.24±0.011 cs WARRANTY o s o ® m Standard' REC ProTrust .......... .... ....... ...._......_.......... o +i Installed byan REC Certified Solar Professional No Yes Yes 0 11±0.2 a ......... .. ...................................................................._.................._..........................._... ._.. [0.43±0.01] System Size All -�25kW 25SOOkW ... ............................................. Product Warranty(yrs) 20 25 25 ...................................._........................_..... - .. ... ......- zo.s±o.s - PowerWarranty(yrs) 25 2S 25 F -- -._;..__........ ....._................... [0.8±0.02] 1200[47.21 - Labor Warranty(y�s)....................__._...__°..__.__........._25.._...._.._.._10.......... ....................... ' Power in Year 1 98% 98% 98% ------ - ......_._..._............._._......_................._.._..... Annual Degradation 0.25% 0.25% 0.25% --c' _._....... - ..................._... t zas[o.9] 671±3I26.4±0.12] __._._._.._.Power in Year2S 92% [ 92% 92% - 30[1.2] See warranty documents for details.Conditions apply Measurements in mm[in] GENERAL DATA QMAXIMUM RATINGS 132half--cut RECheterojunctioncells St5ubliMC4PV-KBT4/KST4,12AWG(4mm') Operational temperature: -40...+185°F(-40...+85°C)' . ...........................................-................................................................... Celltype: with lead-free,gaplesstechnology Connectors: inaccordancewithlEC62852 Maximum system voltage: 1000V 6strings of 22 cells inseries IP68 only when connected ............................•_.......................................................................................... ........................................... .. ................................................ ............ . .........................,................................I.............I............... Maximumtest load(front): +7000Pa(146lbs/sgft)" 0.13in(3.2mm)solar glasswith 12AWG(4mm')PVwire,43+47in(1.1+1.2m) ......................................................................................................................: Glass: Cable:anti-reflection surface treatment accordance with EN50618 Maximumtest load(rear): -4000Pa(83.5lbs/sgft Backsheet: Highly resistant polymer(black) Dimensions: 71.7x40x1.2[n(1821x1016x30mm) Maxseriesf..... .ing: 25A ............................................................................................................ .......................................................... ................................................. Max reverse current: 25A, o Frame: Anodized aluminum(black) Weight: 45lbs(20.5 kg)' SeeinstaIlationmanuat for mount!nginstructions. ................................................................................................................. ................................................................................................................3-part,3bypassdiodes,IP68rated' Design load=Testload/1.5(safetyfactor) L ; Junction box: inaccordance with IEC62790 Origin: Made in'Singapore e° ELECTRICAL DATA Product Code':RECxxxAA Pure _ 9 TEMPERATURE RATINGS' Power Output-PMAX(Wp) 385 390 395 400 405 Nominal Module Operating Temperature: 44°C(±2°C)' A ............................................................. ... .................................................................................................I............................. ........-...................................-......................................................................... . Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 TemperaturecoefficientofPMAX: -0.26%/'C ................................................................. ..................................................................................................................................... ...................................................................................................................... `o NominalPower Voltage-VMPP(V) 41.2 41.5 41.8 42.1 42.4 Temperature coeffic[en'tofVoc: -0.24%/'C ................._............_.-........-........_. ................_.......-..............-....................-................_....................__....._...,..._..........._.......................... ...................................................................................................................... �c u Nominal Power Current-IMPP(A) 9:35 9.40 9.45 9.51 9.56 Temperature coefficient oflsc: 0.04%/'C ...................................................................... . ....... ......... Ln Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 'The temp era turecoefficients state dareIinearvaIues ............. ... ...........................I.. ............................................................................ ... .............................................................. Short Circuit Current-Isc(A) 10.10 10.15 10.20 . 10.25 10.30 - ...._.......... ....................-..............................- -........................................... Power Density(W/sgft) 19.3 19.6 19.8 20.1 20.3 LOW LIGHT BEHAVIOUR .............................. ..... .20.8 Zl.l 21.3 1. .................. .................. ................... ................... Panel Efficiency(%) 21.9 Typical low irradiance performance of module atSTC: N 0 Power Output-PMAX(Wp) 293 297 301 305 309, a NominalPowerVoltage-VMPP(V) 38.8 39.1 39.4 39.7 40.0 ' ................................................... ...................... . .. . . .. ........................................................_.............................-....................... 0 .................. .....g' Nominal Power Current IMPP(A) 7.55 7.59 7.63 7.68 7.72 � m_______________________i...__--__!---------! N Z ..................................................................... ....... ........................:............................................................................................................ w Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46.1 Short Circuit Current-Isc(A) 8.16 8.20 8.24 8.28 8.32 Imadiance(W/m'r a Values at standard test conditions(STC:air massAM 1.5,irradiance 10.75 W/sq ft 0000 W/m'),temperature?-PF(25°C),based on a production spreadwith a tolerance of Pm,V°C&Isc*3%within one watt class.Nominal module operatingtemperature(NMOT:air mass AM 15,irradiance 800 W/m',temperature 687(20°C),windspeed 3.3 ft/s(1 m/s).'Where)°a indicates the nominal power class(PM„X)at STC above. Founded in 1996,REC Group is an international pioneering solar energy 1 REC company dedicated to empowering consumers with clean,affordable RE solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar www.recgroup.com panels it manufactures. Headquartered in Norway with operational tl headquarters in Singapore,REC also has regional hubs in North America, Europe,and Asia-Pacific. dssla Solar Inverter with Solar Shutdown Device Tesla Solar Inverter completes the Tesla home solar system, converting DC power from solar to AC power for home consumption. Tesla's renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels. Once installed, homeowners use the Tesla mobile app to manage their solar system and monitor energy consumption, resulting in a truly unique ecosystem experience. KEY FEATURES • Built on Powerwall technology for 0.5%revenue-grade metering for Solar Renewable exceptional efficiency and reliability Energy Credit(SREC)programs included • Wi-Fi, Ethernet,and cellular connectivity 3.8 kW and 7.6 kW models available with easy over-the-air updates • Designed to integrate with Tesla Powerwall and Tesla App T=S L ri ar ,r - a March 5,2023 Tesla Solar Inverter Technical Specifications - Electrical Specifications: Model Number 1534000-xx-y 1538000-xx-y Output (AQ Output(AC) 3.8 kW 7.6 kW Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V 3,840 VA at 240 V 7,680 VA at 240 V Maximum Continuous Current 16 A 32 A Breaker(Overcurrent Protection) 20 A 40 A Nominal Power Factor 1 -0.9(leading/lagging THD(at Nominal Power) <5% Electrical Specifications: MPPT 2 4 Input (DQ Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60-550 VDC DC MPPT Voltage Range 60-480 VDC' Maximum Current per MPPT(IMP) 13 Az Maximum Short Circuit Current per 17 Az MPPT(Isc) Maximum current. 2 Where the DC input current exceeds an MPPT rating,jumpers can be used to allow a single MPPT to intake additional DC current up to 26 A IMP/34 A Isc• Performance Peak Efficiency 98%at 208 V 98.4%at 208 V Specifications 98.1%at 240 V 98.6%at 240 V CEC Efficiency 97.5%at 208 V 97.5%at 208 V 97.5%at 240 V 98.0%at 240 V Allowable DC/AC Ratio 1.7 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi (2.4 GHz,802.11 b/g/n), Ethernet 3, Cellular(LTE/4G)4 Factory-Installed Revenue Grade Meter Revenue Accurate(+/-0.5%)3 AC Remote Metering Support Wi-Fi(2.4 GHz,802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter(AFCI), Rapid Shutdown Supported Grid Types 60 Hz,240 V Split Phase 60 Hz,208 V,Wye 3 Applicable to Tesla Solar Inverter with Site Controller(1538000-45-y)only. 4 Cellular connectivity subject to network operator service coverage and signal strength. Tesla Solar Inverter and Solar Shutdown Device Datasheet 2 r Tesla Solar Inverter Technical Specifications Mechanical Specifications Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in) 00 00 00 4 ME L w o0 00 00 00 00 00 660 00 00 mm o0 00 - 0 OO 00 158-10 411 mm 101 N mm Weight 52Ibs I I I Mounting Options Wall mount(bracket) s Door and bracket can be removed for a mounting weight of 37 lb. Environmental Specifications Operating Temperature -300C to 450C(-220F to 1130F)6 Operating Humidity(RH) Up to 100%,condensing Storage Temperature -300C to 700C(-220F to 158°F) Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Rating Type 3R Ingress Rating IP55(Wiring compartment) Pollution Rating PD2 for power electronics and terminal wiring compartment, PD3 for all other components Operating Noise @ 1 m <40 db(A) nominal,<50 db(A)maximum 6 For the 7.6 kW Tesla Solar Inverter,performance may be de-rated to 6.2 kW at 240 V or 5.37 kW at 208 V when operating at temperatures greater than 450C. Compliance Information Grid Certifications UL 1741,UL 1741 SA, UL 1741 SB, IEEE 1547-2018, IEEE 1547.1 Safety Certifications UL 1741 PVRSS, UL 1699B, UL 1998(US),UL 3741 Emissions EN 61000-6-3(Residential), FCC 47CFR15.109(a) Tesla Solar Inverter and Solar Shutdown Device Datasheet 3 Solar Shutdown Device 1 Technical Specifications The Solar Shutdown Device is a Mid-Circuit Interrupter(MCI) and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC.When paired with Tesla Solar Inverter,solar array shutdown is initiated by any loss of AC power. Electrical - Nominal Input DC Current Rating(IMP) 12 A Specifications Maximum Input Short Circuit Current(Isc) 19 A Maximum System Voltage(PVHCS) 600 V DC RSD Module Maximum Number of Devices per String 5 Performance Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years Environmental Ambient Temperature -40°C to 50oC(-40°F to,122°F) Specifications Storage Temperature -30oC to 70°C(-22°F to 158°F) Enclosure Rating NEMA 4X/IP65 Compliance Certifications UL 1741 PVRSE, UL 3741, Information PVRSA(Photovoltaic Rapid Shutdown Array) RSD Initiation Method PV System AC Breaker or Switch Compatible Equipment See Compatibility Table below Mechanical Model Number MCI-1 Specifications Electrical Connections MC4 Connector _A_ 250 mm _ Housing Plastic Pail Screw Dimensions 125 mm x 150 mm x 22 mm 650 mm 150 mmM8 Bolt (5inx6inxlin) Weight 350 g (0.77 lb) od Screw Mounting Options ZEP Home Run Clip __ __ M4 Screw(#10) -- -- ---- ---- M8 Bolt(5/16") Nail/Wood screw 22 mm �125 mm- m UL 3741 PV Hazard Control (and PVRSA) Compatibility Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with Tesla Solar Inverter and Solar Shutdown Devices.See Tesla Solar Inverter Rapid Shutdown: Module Selection Based on PV_ Hazard Control System Listing for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS (where xxx=405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules 7 Tesla Tesla TxxxH (where xxx=395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 or Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. Tesla Solar Inverter and Solar Shutdown Device Datasheet 4 The Sna Nrack line of solar mounting :. .-- .;. systems is designed to r educe total a=��;a�x` �.;.x, ,��:.����-; �--�=>: -.•?. installation costs. The system features •tyC.'''fml...c.'A?�".�.��t� technical innovations proven on more „emu ` than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified .: SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps' shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact SnapNrack- Patent Pending H@UI"flRPn)O arobma j Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1°spacer sold separtely Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions ISNAPNRACK CHANNEL NUT 1 �SNAPMtACK 92 DEGREE L•FOOT,CLEAR l 511618 FIANCE NUT �a +�SPLITS LOCK WASHER SPLIT LOCK WASHER —SNAPNRACK COMPOSmON RASMNG Q♦ 3.13 `SNAPNRACK IFODT BASE ,38 SnapNrack Flashed Foot Materials 6000 Series Aluminum L Foot&Base I Stainless Steel Hardware Galvanized Steel Flashing I Material Finish Clear and black anodized aluminum IWeight 0.16 Ibs Design Uplight Load 200 Ibs Uplift I Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack, (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. SERIES 100 RO- OF MOUNT . • • • • Solutlo.ns The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive T -= =}• down costs and improve installation quality on more than 350 MW of solar installations. Pitched Roof Arrays Simplified A: f� rj The SnapNrack Series 100 UL Roof Mount System :� �,:f :,,�,,,,,;�x:,-� ��;•�- .z�,,,.�,4Rs-�. is an efficient,visually appealing, photovoltaic(PV) module installation system. Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional f 1) Go to the online Series 100 Configuration grounding hardware. The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules �`. LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Standard Rail SnapNrack Bonding Split-Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNrack Bonding �- SnapNrack Adjustable End SnapNrack �� Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding . Bonding SnapNrack Adjustable End Stainless Channel Nut Bonding Bolt with Clamp Bottom Channel Nut Stainless Hardware with • Split-Lack Washers Split Lock SnapNrack Bonding SnapNrack Bonding J SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave r � UEC Pull Strap �� _ UEC Wedge Stainless Steel Bolt with Flat Washer IV F IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack "•, Stainless SnapNrack +nr 92 Degree Flange Mill Finish L Foot Bolt Standoff ga y i SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff Base(1-Hole SnapNrack Base Shown) SnapNrack Lashingck Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing I Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to LIL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions I (877) 732-2860 www.SnapNrack.com I A Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved. I Fisher Engineering Services, P.C. g g 509 Sayville Blvd• Sayville •New York 11782 Phone: (631) 786-4419 December 14, 2023 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Agoglia&Hoelzel Residence- 6190 Peconic Bay Boulevard, Laurel,NY 11948 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system(photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2020-Residential Code of New York State (2020 RCNYS),.Long Island Unified Solar Permit Initiative(LIUSPI), 2017 National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the roof utilizing lag screws that have been designed for wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"xl0" on 16" c.c.,with an actual span of 15'-2", with plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, ,✓� NE William G. Fisher, P.E. Licensed Professional Engineer o�c Architectural Design•Residential-Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections a "x SOLAR'S MOST TRUSTED REC �d Iv F 7 MM CY t S2+ � v yYi .F:x' fin. err zap��• �:. Q � EXPERIENCE REE ~w 400wp 25 YEAR PROTRUST ; 20.3 �T2 " WARRA(V� LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE q REC PROOUET • • • SOLAR'S MOST TRUSTED 1821±2.5[71.7±0.1] �i 28[1.1] 901[35.51 460118.1] j CERTIFICATIONS -I IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) ❑ �-s + ISO 14001:2004,ISO 9001:2015,OHSAS 18001:2007,IEC 62941 1100[43.3] - OVE °0- Intertek 6.0±0.2 [0.24±0.01] Q WARRANTY Standard: RECProTrust +i InstalledbyanRECCertified No Yes Yes o tt+oz SolarProfessional .................._..........................._..................................... _.._._._...___.._...._.._.. --..__..__......_.: o'[0.43±0.01] System5ize All e25kW 25-500kW ............... .. ......... ...._......................._................ ._sees. Product Warranty(yrs) 20 25 25 _.__._..................................._..._.................._.-- -..._...._.__._...---- t Power Warranty(yrs) 25 [ 25 25 10.8±0.021 \ 1 1200[47.21 - Labor Warranty(yrs) 0 25 10 a� .............................................._._..._........,._.................----............._........_...... ' Power in Year 1 98% 98Vo 98% ....................... _. - ! ' Annual Degradation %%0.25% 0.25 0.25 0 0 0 22.5(0.91 I 671±3(26.4±0.121 ........sees ......................_................o _o... .... 45[1.8] Power in Year 25 92% 92/0 92/a _30[1.2] See warranty documents for details.Conditions apply Measurements in mm[in] GENERAL DATA QMAXIMUM RATINGS _ 132half-cut REC heterojunction cells StaubliMC4PV-KBT4/KST4,12AWG(4mrn2) 0pe rat ionaltemperature: 40...+185°F(40...+85°C) ................................."...........:........................................................ ..... Celltype: with lead-free,gaplesstechno(ogy Connectors: in accordance withIEC62852 Ma ximum.. .systemv... .oltage:. 1000...V 6stringsof22 cells inseries' IP68onlywhenconnected ...................................................................................... .......................... ............................................. .......................................................... . ............................................................................................sees... Maximum test load(front): +7000Pa(1461bs/sgft)• .... ... Glass: 0.13in(3.2mm)solarglasswith Cable: 12AWG(4mm2)PVwire,43+47i6(1.1+1.2m) - -- ....- -- --- --................................. -----.....--- Maximum test load rear: -4000Pa 83.51bs s ft anti reflection surface treatment accordancewithEN50618 (rear): ( ..q ) Backsheet: Highly resistant polymer(black) Dimensions: 71.7 x40 x1.2 in,(1821 x 1016 x 30 mm) Max series fuse rating: 25A se rase ............................................................................................................... ..............-... ........................................................................................ Max reverse current: 25A o Frame: Anodized aluminum,(black) Weight: 45 lbs(20.5 kg) 'See installation manual for mountinginstructions. ............................................................................ .....:... ...... ................................................................................................................. D / I ) r 3-part,3 bypass diodes,IP68rated Design =Testload 1.5(safety Junction box:, inaccordancewithlEC62790 Origin: Made iriSingapore ELECTRICAL DATA Product Code':RECxxxAA Pure 9 TEMPERATURE RATINGS' Power Output-PMAx(Wp) 385. 390 395 400 405 Nominal Module Operating Temperature: 44°C(±2°C). .............. ............................................................ .... .......................................................................... -.................................................... Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Temperature coefficient ofPMax: -0.26%/°C ............ ................................................................................................................................................_..............sees ................. ... ........................................................................................... o Nominal Power Voltage-VMPP(V) 41.2 41.5 41.8 42.1 42.4 Temperature coefficient ofVoc: -0.24%/°C .................:.................................................................................................................._........................._..........:.......a.... . .....................................................,................................................................. u Nominal Power Current-IMPP(A) 9.35 9.40 9.45 9.51 9.56 Temperature coefficientoflsc: 0.04%/°C F ................ .. . . .. ..... .. ........... ........................... .. ........................... Ln Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 'The temperature coefficients stated are linearvalues .......................................................... ...................................._..sees........................... .... ....._..................................................... Short Circuit Current-Isc(A) 10.10 10.15 10.20 10.25 . 10.30 ........................................s e e s . ...... .............................:...._............................................................................I.......................... Power Density(W/sgft) - 19.3 19.6 . 19.8 20.1 20.3 �LOWLIGHTBEHAVIOUR ................................................... ....... ......................................................................_..................................................-........................... yP P N Panel Efficiency(%) 20.8 21.1 21.3 21.6 21.9 Typical performance T Power output-PMM(WP) 293 297 301 305 309 a ..................................................... .....................-...................................... F Nominal Power Voltage-VMPP(V) 38.8 39.1 39.4 39.7 40.0 o p ........_.........._.._........................................... .........._...... .............................._........................._................................................. d o 2 Nominal Power Current-IMPP(A) 7.55 7.59, 7.63 7.68 7.72 m------------------------=----------[-.-_--. Z ....................................................................................................................................".............................................................................. w o Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46.1 ....................... ................................................. ...............................................................................:..................................I................. . Short Circuit Current-I A 8.16 8.20 8.24 8.28 8.32 m ; m -� sc O Imadtance(W/m J Values at standardtest conditions(STC:air mas5AM1.5,irradiance 10.75 W/sq ft(1000 W/m'),temperature 77F(25°C),based on a production spreadwith a tolerance of P.,Vor&Ix±3%within one watt class.Nominal module operatingtemperature(NMOT:air mass AM 1.5,irradiance 600 W/m',temperature 68°F(20'C),windspeed 3.3 ft/s(1 m/s).'Where xxx indicates the nominal power class(PM.)at STC above. Founded in 1996,REC Group is an international pioneering solar energy r_ company dedicated to empowering consumers with clean,affordable R solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar www•recgroup.com panels it manufactures. Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America, Europe,and Asia-Pacific. tc �• t)6 Teslia Solar Inverter with Solar Shutdown Device Tesla Solar Inverter completes the Tesla home solar system, converting DC power from solar to AC power for home consumption. Tesla's renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels. Once installed, homeowners use the Tesla mobile app to manage their solar system and monitor energy consumption, resulting in a truly unique ecosystem experience. KEY FEATURES • Built on Powerwall technology for 0.5%revenue-grade metering for Solar Renewable exceptional efficiency and reliability Energy Credit(SREC) programs included • Wi-Fi, Ethernet, and cellular connectivity 3.8 kW and 7.6 kW models available with easy over-the-air updates • Designed to integrate with Tesla Powerwall and Tesla App l r. -li yu �'xa+ S' 1 ' .aV. March 5, 2023 1 i J► Tesla Solar Inverter Technical Specifications Electrical Specifications: Model Number 1534000-xx-y 1538000-xx-y Output (AQ Output(AC) 3.8 kW 7.6 kW Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V 3,840 VA at 240 V 7,680 VA at 240 V Maximum Continuous Current 16 A 32 A Breaker(Overcurrent Protection) 20 A 40 A Nominal Power Factor 1 -0.9(leading/lagging THD(at Nominal Power) <5% Electrical Specifications: MPPT 2 4 Input (DQ Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60-550 VDC DC MPPT Voltage Range 60-480 VDC' Maximum Current per MPPT(IMP) 13 Az Maximum Short Circuit Current per 17 Az MPPT(Isc) Maximum current. 2 Where the DC input current exceeds an MPPT rating,jumpers can be used to allow a single MPPT to intake additional DC current up to 26 A IMP/34 A ISC. Performance Peak Efficiency 98%at 208 V 98.4%at 208 V Specifications 98.1%at 240 V 98.6%at 240 V CEC Efficiency 97.5%at 208 V 97.5%at 208 V 97.5%at 240 V 98.0%at 240 V Allowable DC/AC Ratio 1.7 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi (2.4 GHz,802.11 b/g/n), Ethernet;, Cellular(LTE/4G)4 Factory-Installed Revenue Grade Meter Revenue Accurate(+/-0.5%)3 AC Remote Metering Support Wi-Fi(2.4 GHz,802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter(AFCI), Rapid Shutdown Supported Grid Types 60 Hz,240 V Split Phase 60 Hz,208 V Wye 3 Applicable to Tesla Solar Inverter with Site Controller(1538000-45-y)only. 4 Cellular connectivity subject to network operator service coverage and signal strength. Tesla Solar Inverter and Solar Shutdown Device Datasheet 2 •Cr. Solar Shutdown Device 1 Technical Specifications The Solar Shutdown Device is a Mid-Circuit Interrupter(MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC.When paired with Tesla Solar Inverter, solar array shutdown is initiated by any loss of AC power. Electrical Nominal Input DC Current Rating (IMP) 12 A Specifications Maximum Input Short Circuit Current(Isc) 19 A Maximum System Voltage(PVHCS) 600 V DC RSD Module Maximum Number of Devices per String 5 Performance Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years Environmental Ambient Temperature -40°C to 500C(-40°F to 122°F) Specifications Storage Temperature -30oC to 700C(-22°F to 158°F) Enclosure Rating NEMA 4X/IP65 Compliance Certifications UL 1741 PVRSE,UL 3741, Information PVRSA(Photovoltaic Rapid Shutdown Array) RSD Initiation Method PV System AC Breaker or Switch Compatible Equipment See Compatibility Table below f Mechanical Model Number MCI-1 Specifications Electrical Connections MC4 Connector __ __ 250 mm --- __- Housing Plastic M4 Screw Dimensions 125 mm x 150 mm x 22 mm 650 mm 150 mm M8 Bolt (5 in x 6 in x I in) Weight 350 g (0.77 lb) Nail/ - - Wood Screw Mounting Options ZEP Home Run Clip ._ .,� M4 Screw(#10) M8 Bolt(5/16") Nail/Wood screw •22 mm �125 mm� UL 3741 PV Hazard Control (and PVRSA) Compatibility Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with Tesla Solar Inverter and Solar Shutdown Devices.See Tesla Solar Inverter Rapid Shutdown: Module Selection Based on PV Hazard Control System Listing for guidance on installing Tesla Solar Inverter and Solar,�hutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS(where xxx=405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules' Tesla Tesla TxxxH (where xxx=395,to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 or Q:PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 7 Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. Tesla Solar Inverter and Solar Shutdown Device Datasheet 4 `- l Tesla Solar Inverter Technical Specifications Mechanical Specifications Dimensions 660 mm x 411 mm x 158 mm(26 in x 16 in x 6 in) 00 00 00 =o 4o9 LR oi= 00 00 00 o0 00 00 660 =o mm o0 U 00 N----411 mm �'rnm Weight 52lbs I Mounting Options Wall mount(bracket) 6 Door and bracket can be removed for a*mounting weight of 37 lb. Environmental Specifications Operating Temperature -30°C to,450C:(-,22°F to 113°F)6 operating Humidity(RH) Up to 100%,condensing Storage Temperature -300C to•-70°C(-�22°F to 158°F) Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor-rated Enclosure Rating Type 3R Ingress Rating IP55(Wiring compartment) Pollution Rating PD2 for power electronics-and terminal wiring compartment, PD3 fo'r all other`components Operating Noise @ 1 m <40 db(A) nominal,'<50 db(A)maximum 6 For the 7.6 kW Tesla Solar Inverter,performance may be de-rated fo,6.2 kW at 240 V or 5.37 kW at 208 V when operating at temperatures greater than 451C:zs;, f Compliance Information I Grid Certifications UL 1741, UL 1741 SA,UL 1741 SB,IEEE 1547-2018, IEEE 1547.1 Safety Certifications UL 1741 PVRSS, UL 1699B,UL 1998(US),UL 3741 Emissions EN 61000-6-3(Residential), FCC 47CFR15.109(a) Tesla Solar Inverter and Solar Shutdown Device Datasheet 3 i SERIES 100 FLASHED L FOOT Sn,apNra.ck Residential • Systems The SnapNrack line of solar mounting '` systems is designed to reduce total Sd"F; 4> M.N�N�a ,...N� lrr.7y"✓. !Y4 SRi^`��j£'..+. installation costs. The system features technical innovations proven on more than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified s: SnapNrack Series 100 Flashed L Foot Kit is an innovative t% solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Y g Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate.the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the-L Foot. • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at www.snapnrack.com/contact - • No Cutting of shingles SnapNrack- Patent Pending pW M0U[NU[M o avotsm"iB w i i 1 Flashed L Foot Kit Assembled(1"spacer sold separately) Flashed L Foot Kit Parts(1"spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACK CHANNEL NLrr rSNAPNRACK 92 DEGREE L-FOOr,CLEAR / F 5116-18 FLANGE NUT -5/16-18 X 11N BOLT WITH SKIT LOCK WASHER .-SNAPNRACK COMPOSmON FLASHING 0 3.13 SNAPNRACK L-FOOT BASE .Be SnapNrack Flashed Foot Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack, PV, Md doming Systems (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. Y S S• • • ROOF - M -OUNT SnapNrack Solar . Sol utions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System :{o�-ei ixy Jx'x:.yT i �.,f jy,ac`...... is an efficient,visually appealing, photovoltaic(PV) - .-;. � -:��'��: -��nx-✓�:,;, .<.;rXr-- module installation system.Series 100 UL is Listed - - - --- - — - ----- - - to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in,bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules �` LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Bolt with Split Splice Insert Split-Lock Washer Lock Washer - SnapNrack Bonding SnapNrack 4Adjustable End SnapNrack _�` Splice Clamp Top Bonding - Base Mid Clamp ' � SnapNrack SnapNrack Bonding - Bonding SnapNrack Adjustable End Stainless Channel Nut Clamp Bottom Bonding Stainless Hardware with Bolt with JChannel Nut Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack BondingWasher Adjustable End Clamp SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF • MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap �UECWedge Stainless Steel Bolt with Flat Washer F IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Banding Standoff !4 Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Bonding Channel Nut Rubber Steel Flange Nut - Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack stainless SnapNrack °Oj 92 Degree Flange Mill Finish Bolt Standoff L Foot of SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) m SnapNrack Metal Roof L Foot Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding Roof a s Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrackPatent Pending • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to LIL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) Sna,pNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com Cf Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved.