Loading...
HomeMy WebLinkAbout51166-Z tOf$OUTyolo Town of Southold * P.O. Box 1179 +� ,0 53095 Main Rd Ulm. Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45666 Date: 10/23/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 1130 W Creek Ave Cutchogue, NY 11935 Sec/Block/Lot: 103.-13-9 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 07/25/2024 Pursuant to which Building Permit No. 51166 and dated: 09/11/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to: Todebush RD Family Trt Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51166 10/10/2024 PLUMBERS CERTIFICATION: Ut oe Signature *�ofsoo,,yp TOWN OF SOUTHOLD BUILDING DEPARTMENT ' a _ TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51166 Date: 09/11/2024 Permission is hereby granted to: Todebush RD Family Trt PO BOX 5 Cutchogue, NY To: Install a generator accessory to an existing single-family dwelling as applied for per Trustees approval. Premises Located at: 1130 W Creek Ave, Cutchogue, NY 11935 SCTM# 103.-13-9 Pursuant to application dated 07/25/2024 and approved by the Building Inspector. To expire on 03/13/2026. Contractors: Required Inspections: Fees: ACCESSORY $125.00 ELECTRIC -Residential $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total $325.00 Building Inspector '�XoF so�ryol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Jamesh _southoldtownny.gov Southold,NY 11971-0959 �oly� RUNTY, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Roger Todebush Address: 1130 West Creek Ave city:Cutchogue st: New York zip: 11935 Building Permit#: 51 166 Section: 103 Block: 13 Lot: 9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: PKJ Eletrical Corp. Electrician: Peter Jackson License No: ME-60122 SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200a Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200a UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 22kw generator with 100amp breaker, 200amp ats Notes: GENERATOR Inspector Signature: Date: October 10, 2024 1130 west creek ave E SOGIyO� �l �� l [go Wl�i7 cf lam Aue h # TOWN OF SOUTHOLD BUILDING DEPT. ro 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [. ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY;INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [x] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Gj-enle rate?� L�Aa i5MP-,qettv k e.,01 DATE ( ' INSPECTOR t t.. P E L W l' OCT 1 0 2024 FIELD INSPECTION REPORT DATE COMMENTS t� FOUNDATION (1ST) -------------------------------------- FOUNDATION (2ND) z 0 cam" ROUGH FRAMING& PLUMBING W 1 r\ vv r INSULATION PER N.Y.• STATE ENERGY CODE FINAL o\ ADDITIONA COMMENTS $ - Z �rn b O z x d b H ` ��g�fFOtk46" TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 hgps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D 1 R PERMIT N0. � I L 1010 Building Inspector: JUL Z 5 2024 sue° t�. Applications and forms must,'be filled out in their entiret .',lncomplete arfrnent applications will not be accepted: Where the.Applicant.is not,the owner;an �utld�ng®eq Town of Southo►d ',Owner's Authorization form(Page 2)shall,be compl'eted.,' Date: 3� �- c OWNERS)OF-PROPERTY:' JName: -� �v-. _.. __ SCTM#1000- 1 Project Address - Phone#: r _ Email: Mailing Address: t Sa CONTACT PERSON: `. Name: Mailing Address:.__. � �JSS�__.. _.� j� �L .._.__._. Phone#: Email: DESIGN PROFESSIONAL INFORMATION:. . ` Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: ` Name: e _ ._____.___. j� _._ ____._.._ �1 -.__ Mailing Address: �-� Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other -a.tJ-• $ l� W ill the lot be re-graded? ❑Yes %0 Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. )]-Check Box Auer Read ng�sThe owner/contractor/design professTona1 Ts responsible for all drainage and istorm waterissues as provided•by. ::ChapterT36aftheilownCode APPUCATIONISHEftEBY,MADE::to"thes,uIldingMboartmentforthe.tssuancebf,a ouildingPermit"pursuani`tothe;BuildingZone, Ordinance ofthe�tTown.of3euthold,Suffolk,Comity,NeTn!:Yorkand,other appi!s*iLaws;ordinances.orRegulattons;for.thectoristruttion'of byiwings, aildttions;eltgrations r for removar""demolitloq,as herein descrihed The applicant;ages to"comply,:witli;all epplicahle laws,prdlnances,buildaig""code,"_., housingcodeand,regu ations^aindto admit authorized inspectors on•premises and in buTldirig(s);for necessary Inspections False statements made lhenem are ""I punls6able'asa,tlass`i9 m(sdemearior pursuant to"Section 210i45 of thQ.New Yo"rk'State Penal law. e Application Submitted By(print name): j�(/Gt v `� ❑Authorized Agent ❑Owner Signature of Applicant: Date: CONNIE D.BUNCH l Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 SS: Qualified in Suffolk County COUNTY OF Commission Expires April 14,2 MZ� em 'r /--.. being duly sworn,deposes and says that(s)he"is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this dday of 20 C �'�' y q/�un C Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) j �l S Arsiding at 3 V W� G—�`'�, 1�- T'1�� do hereby authorize ` �'� ���"' �� L-�) �� ���"� 1 1 o a I Pp Y on my b half to the To f So thol ildi g De rtment for approval as;7'bed here' . I�Xl : �5 � Owner's Signature Da Print Owner's Name 2 Glenn Goldsmith,President tQF S®(/ry Town Hall Annex A.Nicholas Krupski,Vice President �O� 0�0 54375 Route 25 P.O.Box 1179 Eric Se enoski P Southold,New York 11971 Liz Gillooly Peeples G Q Telephone(631)765-1892 Elizabeth Pee P Fax(631)765-6641 COUM`�,� August 17, 2023 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Roger D. Todebush P.O. Box 5 Cutchogue, NY 11935 RE: 1130 WEST CREEK AVENUE, CUTCHOGUE SCTM#: 1000-103-13-9 Dear Mr. Todebush: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, August 16, 2023: RESOLVED that the Southold Town Board of Trustees APPROVE the Administrative Amendment to Wetland Permit#10048 to install a 25"x48" generator set on a 29"x52" pad, on the north side of the house with two (2) HVAC units; as-built bluestone walkway on cement; 6' high panel fencing on north side of residence; 12" high timber retaining wall; low profile boulder wall east of non-turf area (approximately 45'x18"); increase vegetated non-turf buffer landward by approximately 4' with additional native plantings; eliminate outdoor shower; and as depicted on the site plan prepared by Creative Environmental Design, dated August 14, 2023, and stamped approved on August 16, 2023. Any other activity within 100' of the wetland boundary requires a permit from this office. This is not an approval from any other agency. If you have any questions, please do not hesitate to contact this office. Sincerely, Glenn Goldsmith President, Board of Trustees GG/dd Glenn Goldsmith,President Town Hall Annex A.Nicholas Krupski,Vice President ® ®U ®1 54375 Route 25 ® P.O.Box 1179 Eric Sepenoski Southold,New York 11971 Liz Gillooly Telephone(631) 765-1892 Elizabeth Peeples ® �� Fax(631)765-6641 C®UNT`1,� BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE #2133 C Date: May 30,2024 THIS CERTIFIES that the construction of a two-story single-family dwelling_(1 180 sq.ft. footprint)with attached 192sq_ft seward screened in porch installation of an IA/OWTS septic system; installation of a pervious gravel driveway establishment and perpetual maintenance of a 19'wide.non- turf buffer landward of the top bank with native plantings;linstallation of a 25"x48"generator set onwa 29"x52"pad on the north side of the house with two(2)HVAC units as-built blues one walkway on cement; 6' high panel fencing on north side of residence; 12"high timbe retaining wall; Iow profile boulder wall east of non-turf area(proximately 45'xl8"). At 1130 West Creek Avenue,Cutchogue Suffolk County Tax Map#1000-103-13-9 CWorms to the application for a Trustees Permit heretofore filed in this office Dated September 24,2021 pursuant to which Trustees Wetland Permit#10048 Dated December 15,2021,was issued and Amended on August 16,2023 and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the construction of a two-story,sin Ig e=family dwelling(1 180 sq ft footprint)with attached 192sq ft seward screened in porch installation of an IA/OWTS septic system; installation of a pervious gravel driveway;establishment and perpetual maintenance of a 19' wide non-turf buffer landward of the ton bank with native plantings; installation of a 25"x48"generator set on a 29"x52"pad on the north side of the house with two(2)HVAC units:as-built bluestone walkway on cement; 6'high panel fencing on north side of residence; 12"high timbe retaining wall,• low profile boulder wall east of non-turf area(approximately 45'x18"). The certificate is issued to ROGER D.TODEBUSH owner of the aforesaid property. Authorized Signature OL BUILDING DEPARTMENT- Electrical Inspector S�FF ' q, " ��0 Gym TOWN OF SOUTHOLD c Town Hall Annex - 54375 Main Road - PO Box 1179 o • �� Southold, New York 119�1-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh southoldtownny.gov - seandC@-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Informati n Requ red) Date: Company Name: rKy 6-� L6 1 Electrician's Name: , License No.: (�(, Elec. email: �/�tt. '1- Elec. Phone No: /--� ! r� request an email cop of Certificate of Compliance Elec. Address.: �— JOB SITE INFORMATION (All Information Required) Name: +� Address: =f' Cross Street: Phone No.: 31 Q 27— 7 / g Bldg.Permit #: 151 j (�(p email: Tax Map District: 1000 Section: J d3 Block: aj Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Metbr#, ❑NewService❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 D H Frame. Pole;Work done on Service? Y- ; ] N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fridge HW POOL Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Water Bond Carbon Micro GrbDis Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc , Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments 0% G>oAtmt6r y • •11 -• I ' �"��,=alai,-�y.�•�-5 #wx - •-• .,t ,��•-• ,, ��� �i•i, � •� � '� '•. _- �. ,�=Yam=:�=,';�' � � 1 + �� ,��- "^^ . ' �'• , ' ��Yam:•-.�,•w� � -�'_�.. .����'�'_! Via. r" _ �`,t.. - �• . 1�— ..�'�,Y� ry��r, � � � v •��.�.'.���. i._.._.Y�. h ,�r,�..r.rs. � t, . � '�:;;.. \\II �� 7• ' .....,�...•—� . .r .!•-ram•�� � I• � 4 APR 09 20A + SCDHS Ref No.:R22-0077 ��=r�c fiS+T TER.GHL N SURVEY OF PROPERTY AT FLEET'S NECK TOWN OF SOUTHOLD OLD PASTURE ROAD SUFFOLK COUNTY, N.Y. 1000-103-13-09 SEPTIC LOCATIONS — \ SCALE.' 1=30 A B \ FEBRUARY 9,2021 FEBRUARY 24.2021(VARL LOCARON) 1/A ST 36' 22.5' 1 MARCH 11,2021(FLOOD ZONES ADDED) JANUARY Z 2022(PROPOSED) I ✓ANUARY 18,2022(PROPOSED) DB. 40' 31' AUGUST 21,2023(FINAL SURVEY) MARCH 29,2024(REl4SION) LP1 45' 425' DWELLING I LP2 59' ST PUBLIC WATER I _ I I SANITARY SYSTEM I svr: J., r ••-+ ..,: . .a, ,+NOLL faaJL1=rS::(1) l/A HYDROACTION AN600 SEP77C TANK i LEACHING r,%—APR 15^'N H.S.e.'.r:11t_>�=a9S2 [21 LEACHING POOLS 8' DIA. x 8'DEEP N/D/F CHRISTOPHER M GROOCOK I I tr :'.+^'•n• -..,(+•o: r.,, „ GLORIA G GRODCON ! .,ra••F^.?': =n'.r'J f.+rT_� EXPANSION �o PUBLIC DWEuw G I + y TER WELLI [1]EXPANSION POOL 8'DIA. x 8' DEEP �P'`r I PUBLIC WATER 7EST HOLE DATA Q� _..,�,wsowe c McOONALD GEOSOENLE 1E"Do 19g-A3 r� EL 16.3m 1212912020 °�`- cn EL 16.0' npw z�O Wrae wuPCO�ium1M0 `�W _` (oe7`" $ as'DARK BRONN LOAM OL BROW SANDY �W" z CL• CLAY w 6 N7T T 9 e BROW LYAIEY SAND SP CMF Rl i pw ' Y. mr+tw"r IE -- 3' wwL sett 1 ' O ,�u�•u y R1 r �y �i�� PALE BROW RNE SAND SP 5+ m ! I m nr Z EL�16.3'� N wow POPr Rn:wuL+.1 M.d 'L 197.81' wIX. 1 I Z EL aa' 1S2' It C sasoe��Y+ s w s M« rn ar `�.� n' m I i \ „':� zsw,+�w-,�e�N,:6 k zr wsw I� D�G NOTE WATER ENCOUNTERED I6Y B YELOW '� �l s Lmr or TO.c wnuww N 0 F SURFAf£ GEI(EE WICKHAI/ g ELEYARONS REFERENCED 10 NA VD BB THOMAS WICKHAM EXCEPT•I2'•CONTOUR LINE REFERENCED TO NOW'29 'wa+bE DWELLING WELL UNKNOWN KEY ASSUMED IN BASEMENT Q =REBAR ® =WELL ♦ =STAKE =TEST HOLE • =PIPE ■ =MONUMENT = HETLAND FLAG �IIa a UTILITY POLE DWELLING PUBLIC WATER FEMA ROOD ZONES FROM FTRM 36103COr634 µ41T rv. MAP EFFEC17W DAIS SEPIERUSER 25.2009 TINE LOCATIONS OF N£LLS AND CESSPOOLS SHOW HEREON ARE FROM OBSERVATIONS M• + II AND OR FROM DATA OBTAINED FROMROU THEREFORE HEREFpRE DM LOCATIONSONS AND O4 EXISTENCE AREA= 10,553 SQ FT: /5 NOT GUARANTEED. ANY AL7901110N OR ADDITIOV TO THIS SURLY IS A YIDUTION OF TO TIE LINE r?s 9 N.Ys.uC NO 496Te SECTION 7209 OF THE NEW YORK STATE EDUCANa4 LAN!EXCEPT N.Y.S.uG NO..051132-01 AS PER SECTION 7209-SUBO14MON 2 All OIRTIRGTIGNS HEREON C.P.PELVM RV£Ydt$ ARE VAUD FOR BOS MAP AND COPIES THEREOF ONLY IF SAID MAP (631)765-502p FAX P.C, 71i5-1797 ON COPIES(TEAR THE IMPRESSED SEAL OF THE SURknW NNOSE P.O.BOX 909 MONATURE APPEARS HEREON. SOUTHOLD,L�11971 ,20-090 load APPROVED AS NOTED DATE: -�I"2 B.P# COMPLY WITH ALL CODES OF 14;t a5 0Q BY: NEW YORK STATE&TOWN CODES NOTIFY BUILDING DEPARTMENT AT AS REQUIRED AND CONDITIONS OF 631-765-1802 8AM TO 4PM FOR THE SOUTHOLD TOWN ZBA FOLLOWING INSPECTIONS: _�_ SOUTHOLD TOWN PLANNING BOARD FOUNDATION-TWO REQUIRED 1004 SOUTHOLD TOWN TRUSTEES 0-17--2 3 FOR POURED CONCRETE N.YS.DEC ROUGH-FRAMING&PLUMBING ♦ SOUTHOLD HPC INSULATION SCHD FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS ELECTRICAL INSPECTION REQUIRED RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE GENERAC 16/20/22 kW "_ GUARDIAN° SERIES - rftsidential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Hating %7035-1.G007036-1 0007037-1 :;41uri u n-Bisque)-16 adv 60'17 • True Power'" Electrical Technology 0007o3a-1.G0)7039-1 'Alin,nr r,,-Bisque)-20 wti 60 Hz .G0070-12-10.0007043-10,AI!TInU n-Bisque)-22 K'A'60-17 • Two-line multilingual digital LCD Evolution""controller (English/Spanish/French/Portuguese) - • Two transfer switch options available: ¢^ 100 amp,16 circuit switch or 200 amp service rated smart switch µl' • Electronic governor • Standard Wi-Fi" connectivity available on 16kW and 20kW-1 models and 22kW models • System status&maintenance interval LED indicators _ GENERAC • Sound attenuated enclosure _ - l • Flexible fuel line connector • Natural gas or LP gas operation `r ' • 5 Year limited warranty Product shown with optional fascia kit • Listed and labeled by the Southwest Research Institute allowing c [�� us or c ST uS installation as close as 18 in(457 mm)to a structure,'" ` u(tJl "b14e Must be located away from doors,windows,and fresh air intakes and in ,,,E, LISTED accordance with local Codes. Note:CETL or CUL certtfication only applies to unbundled units and units hilps:/lassets.sivri.org/tibraryiDirectoryOfListedProducts/ ppackaged with limited circuit switches.Units packaged with the Smart Switch are Construcfionlndustryl973_DOC 204_13204-01-01_Aev9.pdf RL or UL certified in the USA only. FEATURES O 114140VATIVE ENGINE DESIGN & RIGOROUS TESTING are at the hear,of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at-±--1%. O TRUE POWER"' ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O S114GLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility qualiy power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST cRr EP.IA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINO CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smartphone,tablet,or PC.Easily access informa- tion such as the current operating status and maintenance alerts.Users can connect an account to an authorized service dealer for fast, friendly,and proactive service. With Mobile Link,users are taken care of before the next power outage. GENERAC r- PROMISE y GENERAC` 16/20/22 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval, • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows fora smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications(applicable to 22 kW units). • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution" Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key lacking roof panel for security.Litt-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC' 16/20/22 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAL` i 6/20/22 kW Specifications Generator _ Model 16 kW 20 kW 22 kW Rated maximum continuous power capacity(LP) 16,000 Watts* 20,000 Watts" 22,000 Watts* Rated maximum continuous power capacity(NG) 16,000 Walls" 18,000 Watts* 19,500 Walls* Rated voltage 240 240 240 Rated maximum continuous load current-240 volts(LP/NG) 66.7/66.7 83.3/75.0 91.7/81.3 Total HarmonicOistortion Less than 5% Main line circuit breaker 70 amp 90 amp 100 amp r Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(I b/kg) 409/186 448/203 466/211 Dimensions(L x W x H)In/cm 48 x 25 x 29/.121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load"* 67 67 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test"low-speed exercise mode" 55 55 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil rapacity Including filter Approx.1.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas fi%hr(m3 1/2 Looadad 218(6.17) 204(5.78) 228(6.46) Full Load 309(8.75) 301(8.52) 327(9.26) Liquid propane 0/hr(gal/hr)Mr] 1/2 Load 74(2.03)(7.701 87(2.37)[8.991 92(2.53)19.571 Full Load 107(2.94)[11.111 130(3.56)[13.481 142(3.90)[14.77) Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.7 4 kPa)for NG.10-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content.multiply 10/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.7 day exerciser. MANUAL Start with starter control,unit slays on.If utility[ails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage LosslRelurn to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger FaulVMissing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload!Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overciank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility poweroutage with correct maintenance performed.No overload capability is available for this rating.(.All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271). *Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/regajoule content,ambient temperature,altitude,engine power and condition.etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)above sea level;and also will decrease approximately 1%for each 10`F(6'C)above 60`F(16`C). "*Sound levels are taken from the Iron[of the generator.Sound levels taken Iron other sides of the generator may be higher depending on installation parameters. GENERAC 1-6/20/22 W Switch Options Limited Circuits Switch Features Model 6007036(16kW) No.of poles 2 • 16 space,24 circuit,breakers not included. Current rating(amps) 100 • Electrically operated,mechanically-held contacts for fast,positive connections. Voltage rating(VAC) 120/240,10 • Rated for all classes of load.100%equipment rated,both inductive and resistive. Utility voltage monitor(fixed)" -Pick-up 80% • 2-pole,250 VAC contactors. -Dropou( 65% • 30 millisecond transfer time. Retum to Utility` Approx.15 sec • Dual coil design. Exercises bi-weekly for 5 minutes* Standard ' ETL or UL Listed Standard • Rated for both copper and aluminum conductors. Total circuits available 24 • Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem breaker capabilities 8 tandems • NEMA/UL 3R aluminum outdoor enclosure al lows for indoor or outdoor mounting Circuit breaker protected Available RMS symmetrical 10,000 Flexibility. Fault current _r 250 volts • Multi listed for use with 1 in standard,tandem,GFCI and AFCI breakers from Siemens, *Function of Evolution controller Murray,Eaton,and Square D for the most flexible and cost effective install. Exercise can be set to weekly or monthly I Dimensions Height Width H1 H2 W1 W2 Depth IV HI in 26.75 30.1 10.5 13.5 1 6.91 cm 67.95 76.45 26.67 34.29 1 17.55 Wire Ranges Conductor Lug I Neutral Lug Ground Lug 1/0-#14 1 2/D-#14 2/0-#14 DEPTH Service Rated Smart Switch t eatures Model 0007037(16 kw)/G007039(20 kW)/ 0007043(22 kW) • Includes digital power management technology(DPM)standard. No.of poles 2 • Intelligently manages up to four air conditioner loads with no additional hardware. Current rating(amps) 200 • Up to eight additional large(240 VAC)loads can be managed when used in Voltage rating(VAC) 120/240,10 conjunction with Smart Management Modules(SMMs). Utility voltage monitor(fixed)` -Pick-up 80% • Electrically operated,mechanically-held contacts for fast,clean connections. -Dropoul 65910 • Rated for all classes of load.100%equipment rated,both inductive and resistive. Return to utility' Approx.13 sec • 2-pole,250 VAC contactors. Exercises bi-vreekly for 5 minutes' Standard EfL or UL listed Standard • Service equipment rated,dual coil design. Enclosure type NEMA/UL 3R • Rated for both aluminum and copper conductors. Circuit breaker protected 22,000 • Main contacts are silver plated or silver alloy to resist welding and sticking. Lug range 250 MCM-#6 *Function of Evolution controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting Exercise can be set to weekly or monthly flexibility. — Dimensions Height Width H1 H2 W1 W2 Depth . in 26.75 30.1 10.5 13.5 6.91 H Hr cm 67.95 76.45 26.67 34.29 17.55 Wire Ranges Conductor Lug Neutral Lug Ground Lug _ -DEPTH- I-Y12--I 350 MCM-#6 350 MCM-#6 2/0-#t14 GENERAC' 1 6/2Q./22 kW Available Accessories Model# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact ). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not Contact Kit be needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is importantto touch up the paintto protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.They manage large G007006-0(100 amp) electrical loads upon startup and shed them to aid in recovery when overloaded.In many cases,using SMM's can re- duce the overall size and cost of the system. G007169-0 Mobile Link®4G LTE Cellular The Mobile Link 413 LTE Cellular Accessory allows users to monitor the status of the generator from anywhere in the Accessory world,using a smart phone,tablet,or PC.Easily access information such as the current operating status and mainte- nance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service. With Mobile Link,users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs 1218.. Model UPC 637.6 mm 148.0 n] G007035 696471074161 G007036 696471074154 G007037 696471074178 G007038 696471074185 G007039 696471074192 G007042 696471074208 72'...2 mm [28.6 m] G007043 696471074215 IMA 0 O O 648 mm 1232 mm [25.5 in] [48.5 inl LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions,00 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com @2022 Generac Power Systems.Inc.All rights reserved. All specifications are subject to change without notice.Pal No.10000000194 Rev.L 03/24/2022