Loading...
HomeMy WebLinkAbout51535-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51535 Date: 01/09/2025 Permission is hereby granted to: Siarhei Palianok 1975 Skunk Ln Cutchogue, NY 11935 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. Premises Located at: 1975 Skunk Ln, Cutchogue, NY 11935 SCTM#97.4-9 Pursuant to application dated 11/12/2024 and approved by the Building Inspector. To expire on 01/09/2027. Contractors: Required Inspections: Fees: CO-RESIDENTIAL $100.00 ELECTRIC -Residential $125.00 SOLAR PANELS $100.00 E $325.00 1-4 ��� Building Inspector � ,uFnK TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 htt aJw . ttitloldtcwntt Date Received APPLICATION FOR BUILDING PERMIT V For Office Use Only r : k ' PERMIT NO. Building Inspector. �,�")�� 2 � W��4 Applications and and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant'is not the owner',an Owner's Authorization form(Page 2)shall be completed. Date:10/28/24 OWNER(S)OF PROPERTY: Name:Ina Palianok scTM # 1000-097.00-04.00-009.000 Project Address:1975 Skunk Ln. Cutchogue, NY 11935 Phone#:631-800-6325 :=Email:polensi@gmaii.com Mailing Address:1975 Skunk Ln Cutchogue, NY 11935 CONTACT PERSON: Name:Trinity Solar- Samuel Magliaro Mailing Address: 5th Ave Unit 1A, Ronkonkoma, NY 11779 Phone#:(631 )319-7233 Email:brittany.gaumer@trinity-solar.com DESIGN PROFESSIONAL INFORMATION: Name:Trinity Solar- Ayracon V. Almaraz Mailing Address:2211 Allenwood Rd. Wall, NJ 07719 Phone#:(631)319-7233 Email:Ayracon.Almaraz@trinity-solar.com CONTRACTOR INFORMATION: Name:Trinity Solar- Samuel Magliaro Mailing Address:2180 5th Ave Unit 1A, Ronkonkoma, NY 11779 Phone#:(631 )319-7233 Email:brittany.gaumer@trinity-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure FgAdcliti w ❑lAlteration ❑R+ pair ❑Demol'i'tion Estimated Cost of Project: ❑Other �otr.r'"� $38,622.82 Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Intended use of property:Solar Panels Zone or use district in which premises is situated. Are there any covenants and restrictions with respect to this property? ❑Yes El No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Trinity Solar- Samuel Magllar0 Authorized Agent ❑Owner Signature of Applicant: 144y-"P,� Date: `v 1 STATE OF NEW YORK) SS: COUNTY OF j,�IIA QQ) �6 being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the COA (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of bv'eV4 , 20 a Notary blic SARAH YARBROUGH NOTARY PUBLIC-STATE OF NEW ORK PROPERTY OWNER AUTHORIZATIO No.01YA6441255 (Where the applicant is not the owner) Qualified in Suffolk County My Commission Expires 09-26-2 26 Ina Palianok residing at 1975 Skunk Ln. Cutchogue NY 1935 TrinitySolar- Samuel Magliaro do hereby authorize to apply on my behalf to the To of thold Building Department for approval as described herein. Owner's Signatsciire Date �W Print Owner's Name 2 tfd " BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 °rc� Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro!Lerr@southoldtownny.gov - seand a,south oldtownn . ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date. 10/28/24 Company Name: Trinity Solar Name: Richard Guarneri License NO.: ME-57843 email: Rich.guarneri@trinity-solarcom Address: 2180 5th Ave Unit IA,Ronkonkoma,NY 11779 Phone NO.: (631)319-7233 JOB SITE INFORMATION (All Information Required) Name: Ina Palianok Address: 1975 Skunk Ln.Cutchogue,NY 11935 Cross Street: Main Rd, Phone NO.: 631-800-6325 Bldg.Permit email: Tax Map District: 1000 Section: 097.00 Block: 04,00 Lot:0o9 o0o BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation ofa utility approved,grid inter-tied,flush mount,rootlnounted,25 Hanwha 410 solar panels,10,25kW photovoltaic electricity generating system Circle All That Apply: Is job ready for inspection?: YES /@ Rough In Final Do you need a Temp Certificate?: YES /(q Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect - Service Reconnected - Underground - Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Forrn.xls r°n E•�pFr s t.Aohrrncnrs � SJ d f Z y v V ''o i N" ,. W *or ° Z 3. srfroFw ZZI.37 a Kossner „ tolm$ ., MAP OF 'AND R AT PECONIC 'TOWN OF SOuTHOLD,fit.Y SGALB: 40`. jo- r dC+*ibe Home'9"o9,C omsi "—chi rnumu Title Yrtsuv*nr.e omp0" "d 4jjee3wakixr� $c nkr as sJrrvd,qtd,Sapf&-b�w Z,196! ;y VAN TUY'L& S rN Lie4msed Land Surveyors Gm*onN �.�porf , Maw York , r qA tl .,W.-- .-•. -...............,w...7 .�.--...... .r........ .. ' DATE(MM/DD/YYYY) c"R,R.. P CERTIFICATE OF LIABILITY INSURANCE 5/28/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAMEA 9 9 Alexander Gillikin Arthur J. Gallagher Risk Management Services, LLC i gNta 856 482 9900 FAX Nq 866-482 1888 300 Fellowship Road E-MAIL m, Suite 200 IaDRss t�rryHlll BSI7.Ctd Ch ltllwAJ corn v_ ___ (, DING COVERAGE ,_.N_IC# INSURED Laurel NJ O80 TRINHEA-03.....INSURERA Gotham Insurance Union Fife Insurance_Com an of Pittsbur _ 25569 m. INSURER B: Trinity Solar LLC INSURER Endurance ��p y �� 194�$ y rance American Specialty Ins Co 2180 Fifth Avenue, Unit 1A : L Underwriters Inc { 1,9917 Ronkonkoma, NY 11779 INSURERD Liberty"Insurance Unde ..,,, INSURER E:Columbia Casualty Compaq_ ,- 3112,7 INSURER F: COVERAGES CERTIFICATE NUMBER:364362391 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. i TR . . __...... TYPE OF INSURANCE POLICY NUMBER MWO Dry YYY I P DD EWY' LIMITS A X COMMERCIAL GENERAL LIABILITY GL202100013378 6/1I2023 6/1/2025 EACH OCCURRENCE $2,000,000 ,,,-- CLAIMS-MADE . OCCUR _PRPV, [' suurr „m$100,000 X MED EXP(Any oneperson) $5.000 PERSONAL&ADV INJURY $1 000 000 G. P ENLAGGREGATELIMITAPPLIES 0 PER. _ENERALAGGREGATE $2„000,000 POLICY( X JE Q OTHER: I LOC PRODUCTS-COMP/OP AGG $2,000 000 AUTOMOBILE LIABILITY CA 2960145 6/1/2024 6/1/2025 mBODILY INJUINGLELNMYT - COMBINED S 000 000 B - X... p ANY AUTO rWa aoc7d�an6 RY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) S AUTOS ONLY AUTOS HIRED NON-OWNED PRCIPERTYC7A914AGE g r- n --,,,, AUTOS ONLY � �AUTOS ONLY I -� � ��L• - CLAIMS-MADE 1000231834-08 6I1I2024 6I1I2025 AGGREGAT s5,000,000 A UMBRELLALIAB X OCCUR EX202300001871 6/1/2023 6/1/2025 EACHOCCURRENCE C m-- ELD30006989102 6/1/2024 6/1/2025 D X EXCESS LIAB E $5,000 000 E DED RETIE.. ... ..�.. m�...-..�..... .�.. ..... ^` NTION$ 7039650582 6/1/2024 6/1/2025 Limit of$5,000,000 $19 000,000 B WORKERS COMPENSATION WC 013588107 6/1/2024 6/1/2025 X PER OTH AND EMPLOYERS'LIABILITY YNN STATUTEH ACCIDENT E'R $1,000,000 OF IC R MEMBER EXCLUDE/D ECUTIVE N/A .(Mandatory mNH) XE.L,DIS Tmm ... ,.. EASE-EAEMPLOYEE.$1,000,00.1)..........................m, If yes,describe under DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT $1,000,000 B -Automobile CA 2960145 6/1/2024 6/1/2025 All Other Units $250/$500 Comp/Collusion Ded,. I{Truck-Tractors and Semi-Trailers $250/$500 I' I DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Route 25 AUTHORIZED REPRESENTATIVE Southold NY 11971 I ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD INEW Workers' CERTIFICATE OF ATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a. Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Trinity Solar,LLC 631-319-7233 2180 Fifth Avenue,Unit 1A 1c.NYS Unemployment Insurance Employer Registration Number of Ronkonkoma,NY 11779 Insured 49-230977 Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i,e,a Wrap-Up Policy) Number 22-3292324 ........... 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) National Union Fire Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box 1 a" 54375 Route 25 Southold, NY 11971 WC 013588107 3c.Policy effective period 6/1/2024 to 6/1/2025 3d.The Proprietor, Partners or Executive Officers are included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder,This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers' Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Michael Price _ (Print name of authorized representative or licensed agent of insurance carrier) Approved by: _ `/`i.(�ZC�2�/"2G�� 6/l/ 024 (Signature) (Date) Title: C.E.O.North America Telephone Number of authorized representative or licensed agent of insurance carrier: Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb,ny.gov Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured, 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. C-105.2 (9-17) REVERSE Workers' CERTIFICATE OF INSURANCE COVERAGE Art Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured TRINITY SOLAR, LLC 2180 FIFTH AVENUE, UNIT 1A 631-319-7233 RONKONKOMA, NY 11779 Work Location of Insured(Only required if coverage is specifically limited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Town of Southold Standard Security Life Insurance Company of New York 54375 Route 25 3b.Policy Number of Entity Listed in Box 1 a Southold, NY 11971 R71757-000 3c.Policy Effective Period 7/1/2013 to 6/1/2025 4. Policy provides the following benefits: 0 A.Both disability and Paid Family Leave benefits. B.Disability benefits only. C.Paid Family Leave benefits only. 5. Policy covers: 0 A.All ofthe employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law., B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as descr`' d above. Date Signed 6/2/2024 By (Signature of insurance carrier'saothoti �.tl Gepans mpta'ts?rat or NYS licensed insurance agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT:lf Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier, this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 46,4C or 5B of Part 1 has been checked) - State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers' Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120,1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) III II11111111111111111111111111111111111111111 IIIII DB 120.1 (12-2_) Additional Instructions for Form D13-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage (Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c, whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first,two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first,two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (12-21)Reverse a i, u z` AA v Suffolk County Department of Labor, Licensing & r Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 01/29/2014 No. H-52821 �g SUFFOLK COUNTY _ _ '3mem Improvement Contractor License se M .£ � , This is to certify that William F Condit - doing business as Trinity Solar LLC _ having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws rules and regulations of the County of Suffolk State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR in the Countyof Suffolk. a _ HIM NOT VALID WITHOUT Restrictions Additional Businesses IS DEPARTMENTAL SEAL " 1111-Solar AND A CURRENT CONSUMER AFFAIRS i ID CARD Al 14 �t Wayne T. Rogers 1 Commissioner - r Suffolk County Dept,of Labor,Licensing&ConsumerA ffalra HOME IMPROVEMENT LICENSE Nana 4rUfLU AM F CONDIT Business Name This Certiffes that the Trinity soMar UC of s�IP Ise er duty eased Ucense Number H-52821 by the tsurro�r tstaek Issued': 0112912014 W`J'T- Rogers Expires: N141J2 2d Commissioner Suffolk County Dept.of Labor,Licensing&Consumer Affairs VASTER ELECTRICAL LICENSE Name RICHARD GUANERI Business Name This cerifies:hat the nearer is duly licensed Tdn-ty Solar Ir•c. :)y the County of suffolk License Number:ME-57643 Rosalie Drago Issued: 12/15/2016 Commissiorer Expires: 12/1l2024 ' -� ss�ssots 515S35 INSTALLATION OF NEW SKUNK LANE*. o� NfW ROOF MOUNTED PV SOLAR SYSTEM • ��� 1975 SKUNK LANES CUTCHOUGE, NY 11935 ��,� 100315 R�FESS10��' Ex : 12 31 2026 A Issued/Revisions 1 PS ISSU ED TO TOWNSHIP FOR PERNHT ID/18/2024 nVICINITY MAP SITE NO. DESCRIPTION DATE SCALE: NTS Project Title: OCCUPANCY OR :: !.a SIARHEI PALIANOK;INA PALIANOK- }` -"-_ TRINITY ACCT#:2024-09-11.71270 USE IS UNLAWFUL Project Address: WITHOUTCERTIFICATE 1975 SKUNK LANE CUTCHOUGE,NY 11935 -- OF OCCUPANCY 41.0249,-72.4640 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEETINDEX - 1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES Drawing Title: RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC - - COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLT AMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM ` DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE 2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE MCB MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MDP MAIN DISTRIBUTION PANEL EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MLO MAIN LUG ONLY DRAWING DATE: 10/18/2024 DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTED COMPLY WITH ALL CODES OF DRAWN BY: 8L IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. MTG MOUNTING N NEUTRAL REVISED BY: 3. THE INSTALLATION READING AND IS PHOTOVOLTAIC SYSTEM SHALL C 16 ALL INFORMATION SHOWN MUST BE NEC NATIONAL ELECTRICAL CODE APPROVED AS NOTED NEW YORK STATE&TOWN COD RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NIC NOT IN CONTRACT UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. NO# NUMBER i AS REQUIRED AND CONDITIONS ystem Information: ES COMPONENT AND INVERTER MANUALS ARTICLE 690E 705. NTS' NOT TO SCALE a DC SYSTEM SIZE: 10.25kW PRIOR A INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS OCP OVER CURRENT PROTECTION DATE: �-� B•P* C(U�j'{.InL D TOWN ZIA CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE ABBREVIATIONS P POLE W V���V W �ta� AC SYSTEM SIZE: 7.6kW ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL cC ns� `/ V ODULE COUNT: 25 POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AMP AMPERE PEI PH m PULL BOX FEE 3� "'VO B i• MOW TOWN PLANNING 8 ODULES USED: HANWHP,410 THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AL ALUMINUM PVC POLY-VINYL CHLORIDE CONDUIT NOTIFY BUILDING DEPARTMENT AT �,Jry ��ry��������Q MODULE SPEC#: Q.PEAK DUO BLK ML-G10+410 PWR POWER SOU11i0l.DTOM If1WIGW 4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF AMP.FRAME UTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR QTY QUANTITY _ CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED ST 631-765-1802 SAM TO 4PM FOR THE EEL N y�,L UTILITY ACCr#: 9641045303 ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL FOLLOWING INSPECTIONS: UTILITY METER M 98300921 SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT (GENERIC TERM OF JSWBD SWITCHBOARD COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY,PROVIDE AS TYP TYPICAL 1, FOUNDATION-TWO REQUIRED Mum DEAL TYPE: SUNNOVA ., , 5. FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND SPECIFIED) U.O.I. UNLESS OTHERWISE INDICATED F(;R POURED CONCRETE THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX WP WEATHERPROOF MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT XFMR TRANSFORMER 2. r�;)tj aH-FRAMING&PLUMBING Rev.No. Sheet TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER +72 MOUNT 72 INCHES TO BOTTOM INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC cU COPPER OF ABOVE FINISHED FLOOR OR 3. INSULATION RETAIN STORM WATER RUNOFF _ IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE P 1 PV 1 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH 4. FINAL-'CONSTRUCTION MUST BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING BE COMPLETE FOR C.O. PURSUANT TO CHAPTER 236 CONVENTIONS HE ANY LOCAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ALL CONSTRUCTION SHALL MEET THE .OF THE TOWN CODE. ELECTRICAL CODE. ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING ., WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION IMPROVEMENTS SHOWN REIN HE SHALL FU FUSE I TE FS LE SWITCH GOVERN. REQUIREMENTS OF THE CODES OF NEW 7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: GND GROUND YORK STATE. NOT RESPONSIBLE FOR • INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER "UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY (CYCLES PER DESIGN OR CONSTRUCTON ERRORS 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) ELI , dai n 4 GENERAL NOTES ' `�-�R-'.r •�' �� ��S O L A R IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. - 2211 Allenwood Road 877-786-7283 Wall,New Jersey07719 www.Trinity-Solar.com E ' ECOFASTEN CLAMP NOTES:•REFER TO MODULE SPECS FOR MODULE DIMENSIONS (REFER TO SPEC SHEET FOR DETAILS) •DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE NEW PV SOLAR MODULE,TYPICAL SOLAR MODULE SOLAR MODULE (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) - ECOFASTEN"L"FOOT ECOFASTEN RAIL NEW MOUNTING FOOT/ATTACHMENT (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) ♦ POINTS,TYPICAL (REFER TO _ X \ ta5 1 i 90 ENGINEERING LETTER FOR SPACING io ¢ - - \ IC- NEW . AND DETAILS) ECOFASTEN SLOT BRACKET BE ERPI DICUL (REFER TO SPEC SHEET FOR DETAILS) N TO BE MOUNTED PERPINDICULAR TO STRUCTURE(REFER TO ECOFASTEN ECOFASTEN CORRUGATED BRACKET SELF TAPPING SCREW s SPECIFICATIco ON I DATA SHEET FOR' (REFER TO SPEC SHEET FOR DETAILS) (REFER DETAILS) TO SPEC SHEET FOR DETAILS) NEW END CLIP,TYPICAL O 0 EXISTING CORRUGATED METAL /p�2 c� (REFER TO ECOFASTEN SPECIFICATION I I �♦ �— �♦ /DATA SHEETFOR DETAILS) (REFER TO ENGINEERS LETTER FOR SPECS) SOLAR MODULES SHALL NOT EXCEED PEAK HEIGHT. tJ� ff11 V NEW MID CLIP,TYPICAL EXISTING RAFTER - 1�l0315 (REFER TO ECOFASTEN SPECIFICATION _ (REFER TO ENGINEERS LETTER FOR SPECIFICATION /� [• c` /DATA SHEET FOR DETAILS) - G S nATTACHMENT&CLIP DETAIL PV MODULE ATTACHMENT ON CORRUGATED METAL ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE Exp: 12/31/2026 ARRAY SCHEDULE Issued/Revisions BACK P. ISSUED TO TOWNSHIP FOR PERMIT N0. DESCRIPTION DATE Project Title: R1 SIARHEI PALIANOK;INA PALIANOK- TRINITY ACCT#:2024-09-1171270 n;n n1z __ ';;a„. Project Address: UD 1,in, AC 1975 SKUNK LANE CUTCHOUGE,NY 11935 41.0249,-72.4640 lR5 . Drawing Title: - _;'-''-; '- ' ---- -"- --- - - • aka �� = --' - ----' �' - , EP m PROPOSED PV SOLAR SYSTEM 1' 11111Z1ZZZZZ LID //L` _—___ __ Drawing Information DRAWING DATE: 10/18/2024 DRAWN BY: BL ---_-- _ - - REVISED BY: System Information: DC SYSTEM SIZE: 10.25kW ±tLt __ _ _ _ AC SYSTEM SIZE: 7.6kW MODULE COUNT: 25 MODULES USED: HANWHA 410 MODULE SPEC#: Q.PEAK DUO BLK ML-G10+410 FRONT UTILITY COMPANY: PSEG-LI - UTILITY ACCT#: 9641645303 NOTES: - UTILITY METER#: 98300921 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEALTYPE: SUNNOVA WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. •° 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Rev.NO. Sheet 4.) AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(E) - ROOF 1 5.) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES:0PITCH 6.) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. ORIENTATION: ATI P 1 PV 2 ORIENTATION:74° ROOF2 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE MODULES:0 CITY SPEC# ORIENTATION:166° R1 INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE SP INDICATES NEW PV ONLY SUBPANEL ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE (UTILITY ACCESSIBLE) TO BE INSTALLED 25 HANWHA 410(Q.PEAK DUO BILK ML-G30+410) ROOF MODULES:0 PITCH:30° INDICATES NEW PV SOLAR MODULE.RED MODULES 1 USE760OH-USMNBL75 y,,. • ORIENTATION:346° I (vl I INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS. DC INDICATES NEW DC DISCONNECT O I I REFER TO EQUIPMENT SCHEDULE FOR SPECS. 15 ECOFASTEN 2012035 CF STD US RAIL AL MLL 171.5 aooF a MODULES:6 OTHER OBSTRUCTIONS INDICATES EX NDICATES ORIENTATION: EP LOCATION:I STING ELECTRICAL PANEL INSIDE I p I INSTALLED OUTSIDE.-ODUCTION METER TO BE SD INDICATES EXISTING SERVICE DISCONNECT PITCH: 254 I , I - ROOF SOLAR MODULES:19 INDICATES NEW INVERTER TO BE PITCH:34 INDICATES NEW FUSED PV DISCONNECT TO BE 2211 Allenwood Road 877-786-7253 ORIENTATION:74 INSTALLED OUTSIDE(UTILITY ACCESSIBLE) � INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH - 2211 New Jersey 07719 www.Tri 877-olar.D 83 REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall, Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH O NEC 2017 SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 25-410W MODULES W/1 SOLAR EDGE U650 PER MODULE L 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON 15 ADC MAX PER STRING �Q'GO V. (�,�� ASHRAE MINIMUM MEAN EXTREME DRY BULB 81.x811 * .� TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO 1 STRING OF 12 MODULES IN SERIES-380 Vmax --- ------ --------------------------------------------------------- INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT 1 STRING OF 13 MODULES IN SERIES-380 Vmax JUNCTION i 9z TEMP=-16"C I 3.)HIGHEST CONTINUOUS AMBIENTTEMPERATURE BASED '2 STRINGS TO BE TERMINATED INSIDE INVERTER 1 ON ASHRAE HIGHEST MONTH 2%DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO I 100315 INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= I N 33"C I S1O` 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN I TEMPERATURES DO NOT EXCEED47"C IN THE UNITED I STATES(PALM SPRINGS,CA IS 44.1-C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED 1 Issued/Revisions SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS I (ALL OF UNITED STATES) _ I 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I Pi ISSUED TO TOWNSHIP FOR PERMIT 3o/1e/2024 NEC 690.12(A)THR0UGH(D) N0. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title: SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) I $IARHEI PALIANOK;INA PALIANOK- 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: 1 POSITIVE CONDUCTORS=RED EXISTING I TRINITY ACCT#:20 24-09-11712 70 NEGATIVE CONDUCTORS=BLACK EXISTING MAIN BREAKER LOAD CENTER NEC 230.5(C)(2) 120/240V 2P40A BACK FEED BREAKER Project Address: UTILITY METER NEC 705.12(B) 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV 240V 10 NOS' I WIRE TYPE RH W-2 OR EQU IVELANT AND SHALL BE 200A MAIN BREAKER 200ABUSBAR INTERNAL REVENUE GRADE MONITORING 1975 SKUNK LANE I PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT CONTAINED WITHIN SOLAR EDGE INVERTER i CUTCHOUGE,NY 11935 SUNLIGHT.SUB ARRAY CONDUIT LONGER24"SHALL SOLAR EDGE PN.RWND-3D-240-MB 41.0249,-72.4640 CONTAIN<_20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN:5 9 CURRENT CARRYING CONDUCTORS. IL 9. Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS OTHERWISE NOTED s I 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON PROPOSED PV SOLAR SYSTEM ROOFTOP AND SHALL BE LIMITED TO 12"IF USED ` 60 UNFUSED UNFUSED DISCONNECT DISCONNECT D OUTDOORS 240V 10 240V _il INVERTER#1 11.)0VERCURRENT PROTECTION FOR CONDUCTORS Drawing Information �mmmmem memmmm CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE �� ---a+ DRAWING DATE: 10/18/2024 LOCATED WITHIN 10'OFTHE POINT OF CONNECTION NEC 705.31 ) I I DRAWN BY: BL r---T-- ---- �� I REVISEDBV: 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A I I o l 7T. ] e I I a i--J UTILITY AND THE OTHER AN INVERTER,PV BACKFEED - B L - B _ L E Ll L2 N 1 IJ' System Information: - BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY r m z m r --------------------------- m e m m m m - memmmm I NEC 705.12(B)(2)(3)(b) L-----------� 1 1 I I I DC SYSTEM SIZE: 10.25kW SQUARED SQUARE D I L!�- --� AC SYSTEM SIZE: 7.6kW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY DU222RB DU222R8 I I GENERATION CIRCUITS AND NO UNUSED POSITIONS OR E---------J MODULE COUNT: 25 LOADS MODULES USED: HANWHA 410 MODULE SPEC#: Q.PEAK DUO BLK ML-G10+410 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING UTILITY COMPANY: PSEG-LI UTILITY ACCT#: 9641045303 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER#: 98300921 REQUIRED CONDUCTOR AMPACITY PER STRING DEALTYPE: SUNNOVA [NEC 690.8(B)(1)1:(15.00'1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA 410(Q.PEAK DUO BLK ML-G10+410) AMBIENTTEMP:33"C,TEMP DERATING FACT0R:.96 Rev.No. Sheet RACEWAY DERATING=4 CCC:0.80 Imp 10.89 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR (40'.96)0.80=30.72A Vmp .37.64 TO MEET OR EXCEED NEC AND LOCAL ARID REQUIREMENTS �� 30.72A'-18.75A,THEREFORE WIRE SIZE ISVALID Voc 45.37 A #6THWN-2T0GEC I Pi TOTAL AC REQUIRED CONDUCTOR AMPACITY 11sc 11.2 B I"CONDUIT W/2-118 THWN-2,1410 THWN-2,1-#10THWN-2 GROUND _32.00A'1.25=40.00A C 1"CONDUIT W/4-410 THWN-2,.1-#10 THWN-2 GROUND AWG#8,DERATED AMPACITY INVERTER#1-USE760OH-USMNBL75 AM BI ENT TEM P:30°C,TEMP DERATING:1.0 RACEWAY DERATING`3 CCC:N/A DC AC D 1"CONDUIT W/4-#10 THWN-2,1-#10THWN-2 GROUND 55A•1.0=55A Imp 26.97 Pout 7600 E 1"CONDUITW/2-#BTHWN-2,1410THWN-2,1-#10THWN-2GROUND 55A'-40.00A,THEREFORE AC WIRE SIZE IS VALID Vmp 380 Imax 32 F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY OSOLA TOTAL INVERTER CURRENT:32.00A Isc 30 Vnom 240 qR CALCULATION FOR CURRENT: CURRE Voc 480 OCPDmin 40 NT PROTECTION G 1"CONDUIT W/2-#6THWN-2,1-#6THWN-2,1-#B THWN-2 GROUND 32.00A'1.25=40.00A 2211 Allenwood Road 877-786-7283 -->40A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 www.Trinity-Solar.com CTC)n i October 30,2024 SOLAR Trinity Solar No.2024-09-1171270 Southold Town,NY RE:SIARHEI PALIANOK;INA PALIANOK Town Hall Annex Building54375 Route 25 P.O.Box 1179 1975 skunk lane Southold,NY 11971 Cutchouge,NY 11935 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic(PV)system on the existing roof framing components at the above-referenced location.Trinity Solar,LLC has confirmed this structure is permitted by the local jurisdiction and has provided all relevant documentation regarding the existing structure.As of the date of this evaluation,no concerns nor deficiencies related to the existing structure have been reported.Therefore,this assessment is based on the premise the existing structure is in good condition and capable of supporting the existing loads.This evaluation is strictly limited to the support of the PV system and does not extend to any other structural elements not directly involved in the solar panel installation.If any discrepancies from the actual conditions are identified,or if concerns regarding the existing structure arise,this office must be notified prior to proceeding with the installation.All spans listed below are horizontal projections. 1.Existing Roof Framing: •Conventional roof framing at R4 and R5:2X6 at 16 o.c.;existing rafter span is the max unsupported span=14'-0" 2.Roof Loading: •3.00psf-New PV array load(PV panels,mounting rails,and hardware) •6.14psf-Existing roof dead load(1.47psf-2X6 at 16"o.c.roof rafters,4.67psf-roof covering) •20psf-Ground snow load -per AHJ(Authority Having Jurisdiction) •Exposure Category B,130mph design wind speed 3.Existing Roof Modification: •R4 and R5-No modification required.Existing roof framing is acceptable for PV installation. 4.Attachments: •The maximum allowable spacing of the ECOFASTEN-L-FOOT*attachments can't exceed more than 48".Attachments to be fastened using quantity(1) 5/16"x 4"Lag Bolt with a minimum penetration depth of 3"-this is adequate to resist all stated demand loads above.Install attachments,rails,and panels per manufacturer requirements.Stagger attachments to distribute load. *ATTACHMENT TO BE SECURED TO RAFTERS NO LESS THAN 2x4 IN SIZE WITH A MINIMUM 7/16"DECK.CONTRACTOR TO INFORM THIS OFFICE IF ANY ITEM ABOVE DIFFERS FROM SITE CONDITIONS. The installation,described above,is in general conformance with the manufacturers'specifications and complies with all applicable laws,codes,and ordinances as specified by applicable codes,including the 2020 Residential Code of New York State and ASCE 7-16. It should be noted that only PV-supported roofs are reviewed.Trinity Solar is not responsible for any construction flaws or defects that may currently exist in areas of the structure that are not directly related to the PV installation. Regards, Ayracon Almaraz,PE Structural Engineer-Trinity Solar V. 1k � sue * 100315 tv�� AR�FESStONp�' License No.100315,expiration date:12/31/2026 Trinity Solar 2180 5th Avenue,Unit 11 Ronkonkoma,NY 1(631)319-7233 NOTES: 1.)COMPLIES WITH NEC 2017 2.)REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 3.)STICKERS,LABELS,AND PLACKAROS SHALL BE OF SUFFICIENT DURRABILITY TO WITHSTAND THE ENVIROMENT INVOLVED To he located on all DCjunctlon boxes and every 10'on DC conduit y� • • • - SOLAR NEC690.31(G) •"`• NEC 690.56(C)(1)(A) DC function Be. r_ •• • • • . MOM•• 1 1 ' 690.56(C)(3) NEC 690.4(B) 'im ercer+a .gym X:R Service Disconnect • : .= 690.56(C)(3) NEC 690.13(e) NEC 690.53 Soladeck utility • • • • p rvema:u nwar v+zup NEC 690.4(B) II/ J�'u, III L�Te'-J NEC 690,13(B)NONE I NEC 690.56(L)(1J(A) If System is Backfed Breaker NEC 690.54 NEC 690.53 T NEC 705.12(B)(2) I t - DC Disconnect NEC 690.54 Utility Meter Socket 1 �, '� hremcu apd Hoop) ` nw. C690.13(B) NEC 690.54 (+,!( a•.NEC 690.13(B) i JI DC Conduit Main Service Panel Solar Meter Socket Photovoltaic Load Center Inverter(s) Enphase Envoy Box AC Disconnect To Combine Inverters) AK DUO BLK ML-G10+ SERIES ■Mechanical Specification 0'PB)9 mm7 Format 74.0 in x 41.1 in x 1.26ir(including frame) aanoea,..I is a'as 5mml (1879 mm x 1045 mm x 32 rrm) Weight 48.5 lbs(22.0 kg) Front Cover 0.13 in(3.2mm)thermally pre-stressed glass " a-.1n,iPmPr.°°1a c.smml x492'n8omml with anti-reflection technology 3a 2'(,as mm� Back Cover Composite film Frame Black anodised aluminium Cell 6 x 22 monocrystalline Q.ANTUM solar half cells � °s2'f252 mm1 Junction box 2.09-3.98in x 1.26-2.36in x 059-0.71in (53-101mm x 32-60mm x 15-18mm).IP67,wth bypass diodes aml maraca __ Cable 4 mm2 Solar cable;(+)>g9.21n(1250 min),(-)_>49.2 in(1250 min) 1 I o a1a O6S efi min' Connector Sta 12s'p2 mint ubli MC4;IP68 r O e as-n4smml T ■Electrical Characteristics POWER CLASS 385 390 395 400 .405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STCI(POWER TOLERANCE-5 W/-0 W) Power at MPP' PM„ [W] 385 390 395 400 405 410 Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 11.20 E Open Circuit Voltage' Voc M 45.19 45.23 45.27 45.30 45.34 45.37 S Current at MPP IWPP [A] 10.59 10.65 10.71 10.77 10.83 10.89 Voltage at MPP V., M 36.36 36.62 36.88 37.13 37.39 37.64 Efficiency' r1 [%] z19.6 219.9 220.1 z20.4 >>>20.6 2:20.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP P,f„ [W] 288.8 292.6 296.3 300.1 303.8 307.6 'c Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 9.03 Open Circuit Voltage Vac M 42.62 42.65 42.69 42.72 42.76 42.79 2 Current at MPP I-P [A] 8.35 8.41 8.46 8.51 8.57 8.62 Voltage at MPP VI-P [V] 34.59 34.81 35.03 35.25 35.46 35.68 'Measurement tolerances P.,P±3%;Isc;Voc±S%at STC:1000 W/m",25±2°C.AM 1.5 according to IEC 60904-3•2800 W/m2,NMOT,spectrum AM 1.5 r Ocells PERFORMANCE WARRANTY .PERFORMANCE AT LOW IRRADIANCE +� At least 98%of nominal power +m during first year.Thereafter max. u o ss -- --- 0.5%degradation per year.At w c least 93 u.5%ot nominal power u +m --,-----y-------- i up to 10 years.At least 86%of onominal power up to 25 years. wz 5 0° All data within measurement 90 w w¢ tolerances.Full warranties in G accordance with the warranty f terms of the Qcells salesse a o 0 as 10 1s 20 2s organisation of your respective xoa 400 sea sealoan YEARS country. IRRADIANCE IWhn) 'Standard terms of guarantee for the 5 PV companies with the Typcal module performance under low uradumce conddwns m highest production capacity m 2021(February 2021) comparison to SIC conditions(25'C,1000 W/m). TEMPERATURE COEFFICIENTS _ Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc _ R [%/K] -0.27 1 09±5.4 Temperature Coefficient of PMPP y b/K] -0.34 Nominal Module Operating Temperature NMOT rF] (43+3°C) ■Properties for System Design o Maximum System Voltage Vsys M 1000(IEC)/1000(UL) PV module classification Class II a Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 0 Max.Design Load,Push/PUII2 [Ibs/ft2] 75(3600Pa)/55(2660Pa) Permitted Module Temperature -40"F up to+185°F on Continuous Duty (-40"C up[o+85"C) Max.Test Load,Push/Pull3 [Ibs/ft2] 113(5400 Pa)/84(4000 Pa) - 3 See Installation Manual ■Qualifications and Certificates UL 61730,CE-compliant. _ Quality Controlled PV-TUV Rheinland, _ IEC 61215:2016,IEC 61730:2016, w ww _ U.S.Patent No.9,t .215(solar cells), Vtltl1111•• :a atsaa IDIII12 2; N Ocells pursues minimizing paper output in consideration of the global environment. Note:Installation instructions must be followed.Contact our technical service for f-her information on approved installation of this product ���I I V Hnnwn;�Q CELLS Am-ca Inc 400 Spectrum Center Dnve.Sude t400,Irvine.CA 92618.USA I TEL*1 949 748 5996 1 Ctr1AIL hgc.inquiryedgcells.com I tNC6 v mgcells.com OPEAK DUO BLK IIN IVIL-G10+ SERIES Qcells 385-410 Wp 1132 Cells 20.9% Maximum Module Efficiency MODEL Q.PEAK DUO BILK ML-G10+ 4n Breaking the 20%efficiency barrier HQ.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. A reliable investment Inclusive 25-year product warranty and 25-year linear We raillty performance warranty'. Enduring high performance Long-term yield security with Anti LeTID Technology, ocells Anti PID Technologyz and Hot-Spot Protect. Extreme weather rating High-tech aluminium alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). Innovative all-weather technology - Optimal yields,whatever the weather with excellent low-light and temperature behaviour. 6 busbar 12 busbar cell technology cell technology n The most thorough testing �i•/\,J( programme in the industry Qcells is the first solar module manufacturer to pass the most comprehensive quality programme in the industry:The new"Quality Controlled PW of the independent certification institute TUV Rheinland. See data sheet on rear for further nformalion. APT test mrdirons according to IEC/TS 62804-1:2015,method A(-1500V,96 h) The ideal solution for: Rooftop arrays on TG°q''d"°"a residential buildings USA" �U® . EcoFasten For InstaLlers. By Installers. COMPLETE RAIL-BASED RACKING SYSTEM ClickFit is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In rail assembly,the Composition Shingle, Tile,Metal rails can be connected to any of EcoFasten's composition shingle,tile, and metal roof mounts in seconds without ---- — —--- --- — --___s' the need for fasteners or tools. The ClickFit system is made of robust materials such as aluminum and coated Rail-Based i steel, to ensure corrosion-resistance and longevity. ClickFit conforms to UL 2703 and has been tested in extreme weather conditions including wind,fire, and snow. f Structural-Attach FEATURES & BENEFITS Direct-Attach • Tool-less,fastener-free rail attachment • Fully integrated bonding • Click-On Mid&End Clamps • Compatible with a variety of EcoFasten roof attachments FAST INSTALLING SYSTEM FEATURING �zs YEAR WARRANTY � c CLICK-IN RAIL ASSEMBLY wmtwi F WITI INTERNAL SPLICE Tool-free bonded internal Splice installs in seconds. MLPE MOUNT Attach Module Level Power MID CLAMP Electronics to the top of the rail. ,rx Click-on mid clamp features integrated bonding pins and fits modules 30-50 m m in width. END CLAMP Click-on end clamp fits modules END C A P 30-50mm in width. The slide-on end caps allow the end clamps to be accurately positioned on the rail in seconds, while providing an aesthetically- pleasing, finished install. L- FOOT k The ClickFit rail simply clicks into our proprietary composition ; r shingle & the L-foot without the need to use fasteners or tools. : i s F COMPOSITION S H I N G LE Combine.the versatile ClickFit L-Footwith'the watertight' "- GF-1 flashing for a fast 1 installation on composition shingle roofs. GF-1 FLASHING&L-FOOT TILE ROOFS Use the adjustable ClickFit Tile. E ' { Hook for attaching the ClickFit I system to the roofs.Works with ' Flat, S, and W the profiles.. - r CLICKFIT TILE HOOK STANDING SEA ETAL 0 _FS_ ... _—____.__._ _-- _ __ e Combine the ClickFit L-Foot with SimpleBlock°-U for a fast installation on standing # seam metal roofs. I SIMPLEBLOCK-U �1 1 T l� IMAGE NUMBER DESCRIPTION LqUAONX�Trff QUANITY PRODUCT PART ' PART PALLET ASSEMBLED WITH(1)BF GROMMET AND INCLUDES(1)5/16"EPOM BONDED WASHER - GF1M GAL BLK 810 cF1 exlo"BLK GLV so 3200 W/2"HL PLCMT .- GF1-GAL-BLK-812 GFi BX12"GALVALUME BLK 50 2600 FLASHING ALL HARDWARE INCLUDED WITH OO 1500004 CFL-FOOTASSY 100 5000 (NO HARDWARE NEEOEO) 1500005 CF TILE HOOK US 20 480 1510045 CF TILE HOOK SUB-(LASHING 20 2160 TILE HOOK FLSH-F ST TILE HOOK FLASH 12 576 FLAT SIERRA TAN TILE HOOK FLSH-VV ST TILE HOOK FLASH 12 576 W SIERRA TAN TILE HOOK FLSH-S ST TILE HOOK FLASH 12 576 S SIERRA TAN SIMPLEBLOCK-U-AL 2"SIMPLEBLOCK SSR-AL 25 4400 ALL HARDWARE INCLUDED WITH OO 1500004 CFL-FOOTASSY 50 5000 (NO HARDWARE NEEOEOI 1500033 CF RAIL 2130MM N/A 108 (-7 FT CF RAIL 3166MM 1500034 N/A 108 (-10 4 FT) 1500035 CF RAIL 4202MM N/A 108 (-13.8 FT) 1008061 CF RAIL SPLICE 100 3200 1510070 CF WIRE MGMT CLIP 1000 TBO d 1500028 MODULE UMP R,8 IN 25 25000 (204 Er� 1510057 CF MLPE MOUNT 400 17600 PRODUCT PART 9 PART BOX PALLET IMAGE NUMBER 1 DESCRIPTION QUANTITY QUANTITY 1510041 CF ENOCAP,BLK LABELED 100 4800 1510015 CF HO ENDCLAMP 20 5600 30MM,BLK 1510015 CF HO ENDCLAMP 50 5600 32MM,BLK 1510017 CF HO ENDCLAMP 50 5600 35MM,BLK 1510018 CF HO 38MM,B KMP 50 6600 1510019 CF HO ENDCLAMP 50 5600 40MM,BLK 1510020 CF HD ENDCLAMP 60 6600 45MM,BLK 1510011 CF HD MIDCLAMP 50 5600 30-40MM,BLK Af 1510012 CF HD MIDCLAMP 50 5600 40-50MM,BLK ROCK-IT V3 SKIRT A55 35MM R M& SKIRT V3 8 256 &40MM 65" ROCK-IT V3 SKIRT A79 ROCK-IT SKIRT 79 8 256 35MM&40MM 79" ROCK-IT V3 SKIRT A60 ROCK-IT SKIRT V3 8 256 VPPPPPP 35MM&40MM 80" ROCK-IT V3 SKIRT B65 ROCK-IT SKIRT V3 B 256 32MM&38MM 65" ROCK-IT V3 SKIRT B79 ROCK-IT SKI B 256 32MM&38MM 79 79" ROCK-IT V3 SKIRT BBO ROCK-IT SKIRT3 8 256 3BMM 8 32MM&38MM 0 1500003 CF UNIVERSAL SKIRT 50 6750 CLAMP BLK POLY KIT LAS SCREW 4 POLY KIT LAG 50 480 SCREW 4"(50) SCRW OP 15-13XO3 ROOFING SCRW 1000 60000 #15 X 3"DRILL PT INCLUDES(1)2"LAG :O 1510001 CONOUITMOUNT-BRKT 50 10350 fA !>y CONOUITMOUNT-TILE CONDUIT MOUNT-TILE SYSTEM 60 4320 i 4 CLICKFIT i�- - - _'�n�„� �����- ��y �C.-arr � -��v'ti.�."��-_� ��yy,'ti Y>�\,'�T�`+� ". ..-�.,•�c—�.rn---^.��v�- �.t.,__-. oe f� 'il�'31.T2�'`��c�i�-��`R�Ipl.L � �.� v _.'M• \\mil �r'-�� �- l �.,� \ 'lc-�.s�, .gyp \ '\V` ❑, n'.+�`?c,+� ,\�\\"\� \\\ \.:tip •\� - �_. �'�-�~-� \� � b- 0.6 •• • • • • • • v -Single Phase Inv ' erter z . I with HD-Wave Technology m for North America- SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US SE10000H-US SE11400H-US m { 7C7 0 o i i o O O solar=.. D O solar3 _110— ® j ® 10 1 ! Optimized installation with HD-Wave technology / Specifically designed to work with / UL1741 SA certified,for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency / Extremely small / Quick and easy inverter commissioning directly / guilt-in module-level monitoring from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5%accuracy) solaredge.com solar=@@ �t .y ® Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US APPLICABLE TO INVERTERS WITH SEXXXXH-XXXXXBXX4 PART NUMBER ;OUTPUT- Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min:Nom.-Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.5' Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output _ 16 - 24 - - 48.5 A Current @208V Power Factor 1,adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds •INPUT Maximum DC Power @240V 4650 5900 7750 1 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V-; 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V' - 9 13.5 - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W For other regional settings please contact SolarEdge support �n A higher current source may be used;the inverter will limit its input current to the values stated ✓r✓ / Single Phase Inverter Wit H D-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optionaf'1 Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety 1-111741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B ,INSTALLATION SPECIFICATIONS ' AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/AWG Range 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60'1 `F/-C Protection Rating NEMA 4X(Inverter with Safety Switch) t31 Revenue grade inverter P/N:SExxxxH-USOOOBNC4 Full power up to at least 50'C/122`F;for power de-rating information refer to:https.,//www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf m SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Ro H S other trademarks mentioned herein are trademarks of their respective ovmers.Date:52019N01/ENG NAM.Subject to change without notice.