Loading...
HomeMy WebLinkAbout50772-Z �o�OSUFF�I�cpG. Town of Southold 10/3/2024 a y� P.O.Box 1179 0 o • t 53095 Main Rd by o�,1 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45613 Date: 10/3/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 905 Willow Dr, East Marion SCTM#: 473889 Sec/Block/Lot: 22.-5-12 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/22/2024 pursuant to which Building Permit No. 50772 dated 5/31/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Bletsas,John&Kathy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50772 9/12/2024 PLUMBERS CERTIFICATION DATED N n n th rize ignature TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50772 Date: 5/31/2024 Permission is hereby granted to: Bletsas, John 37-20 58th St Woodside, NY 11377 To: Install a generator accessory to an existing single-family dwelling as applied for as per manufacturers specifications. At premises located at: 905 Willow Dr, East Marion SCTM #473889 Sec/Block/Lot# 22.-5-12 Pursuant to application dated 4/22/2024 and approved by the Building Inspector. To expire on 1113012025. Fees: ACCESSORY $125.00 CO-RESIDENTIAL $100.00 ELECTRIC $100.00 Total: $325.00 Building Inspector ho��pF SOUT��I 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q (c� y �o sean.devlintown.southold.ny.us Southold,NY 11971-0959 couff ,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: John Bletsas Address: 905 Willow Dr city,East Marion st: NY zip: 11939 Building Permit#: 50772 Section: 22 Block: 5 Lot: 12 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Instone Electric Corp License No: 66421 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 150X2 UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 26kW Generac Generator w/ (2)150A Transfer Switches Notes: Generator Inspector Signature: ate: September 12, 2024 S.Devlin-Cert Electrical Compliance Form OFSOGTyOIo Sv 2 TW � V ✓ " . � i � - * * N- ;.S OUTHOLD BUILDING DEPT. �o O Courm,�� 631-765-1802 INSPECTION ' [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ]'.FIREPLACE & CHIMNEY [ ] .FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) . ELECTRICAL (FINAL) [ - ] CODE VIOLATION ] PRE.C/O [ ] RENTAL REMARKS: � DATE 2-C INSPECTOR �� OF SOUTyo� # . # TOWN OF. SOUTHOLD BUILDING DEPT. coo►m,��' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] .IN LATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] . FIREPLACE'& CHIMNEY [ ] "FIRE.SAFETY INSPECTION [ " ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH)- [ ] ELECTRICAL (FINAL) [ ] .CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: r\ n I DATE Of - INSPECTOR s � do fix`.Ai �? +, , IN I � owly� �►� ���a��- i�` R �,•.S-'!fie-1 ax �� . r )III �'�� A � i, a _ �► rh or s .. s L I P F o�o�SOfFO�AcOGy�2 TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box H 79 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.g_ov Date Received APPLICATION FOR BUILDING PERMIT _... For Office Use Only PERMIT NO.�10 I ! Building Inspector: APR 2 2 2024 Applications and forms must be filled out in their entirety.Incomplete V1111ay ? ? , applications will not be accepted. Where the Applicant is not the owner,an FT �;r ;i n' �i' ; Owner's Authorization form(Page 2)shall be completed. Date:4/22/24 OWNER(S)OF PROPERTY: Name:John Bletsas SCTM#1000-22-05-12 Project Address:905 Will Drive, East Marion Phone#:917 681 1953 Email:jbletsas@bletsasplumbing.com Mailing Address: CONTACT PERSON: Name_Brooke Epperson Mailing Address:PO Box 152, Mattituck, NY 11952 Phone#:631 6039092 Email:bepperson@amparchitect.com DESIGN PROFESSIONAL INFORMATION: Name:Anthony Portillo Mailing Address:p0_Box 152,_Mattituck, N.Y. 11952 Phone#:631 603 9092 Emaik aportillo@a mparchitect.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: [il0therGenerator $3,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION t Existing use of property: n Intended use of property.Single Family Residence ' Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 Nonconforming this property? ❑Yes BNo I F YES,PROVIDE A COPY. Check Box After Reading: Theowner/contractor/destgn professional 19 responsible forall drainage and storm water issues as proWdad by Chapter 296 of the Town Code.APPLICATION IS HE MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and otherappBroble Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable taws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary,Inspections.False statements made herein are pun4hable as a Class A misdemeanor pursuant to Section 218AS of the New York State Penal Lew. Application Submitted By((pprint name):AMP Architecture, , ®Authorized Agent ❑Owner Signature of Applicant: ( , / Date: ZZ 2� �- 1 STATE OF NEW YORK) SS: COUN OF Suffolk ). o Q�, :� _being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing c ntract)above named, (S)he is the, Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this' -&L—day of AyY1` 20 2-4 ` :)rLt 'A !� Notar ubii DARCEE AUFENANGEI NOTARY PUBLIC,STATE OF NEVi YORK PROPERTY OWNER AUTHORIZATION Registration No.01AU001 44 (Where the applicant is not the owner) Qualified in Suffolk Coun Commission Expires.January. 2028 I, j04 C�► J �s residing at J ►, c�(,� t/l t�� ,�A— OU(i 30 do hereby authorize -to.apply on my behalf to the T wn of Southold Building Department for approval as described herein. Io Zo . Owner's Signature Date SA Print Owner's Name 2 v_ iLs` U�Ll Vr ' BUILDING DEPARTMENT- Electrical Inspg r O C J� P 1 '! ?024 TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0966'.'�a nTp-,m, s��y Telephone (631) 765-1802 - FAX (63'1`) 765-9" .� lamesh(cDsoutholdtownny.gov -- seand(D.southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: �p Zt`rZ Company Name: -InStb e- { G C.v r' Electrician's Name: hrfcli1 ne- License No.: Me - ( oq 2( Elec. email: Sftne 6D 5tUn,C-ekQ yiC • rc+ Elec. Phone No: 6I6- 4s62-- .9.3LJ(o -request an email copy of Certificate of Compliance Elec. Address.: 9CH -11>n S-AYf JOB SITE INFORMATION (All Information Required) Name: -J-olgy B I eioJ o-'s Address: 9 o6 T_ a-&`k MCA-Irlbn Cross Street: Smax—S j Phone No.: Bldg.Permit#: G Z email: bl-e- CLA '���j •C( Tax Map District: 1000 Section: 2Z Block: Lot: %2 �J BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): C-5v CAL C CU-) 210 Y-W fOe,,ra � Square Footage: Circle All That Apply: Is job ready for inspection?: [�rYESF-] NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ®NO Issued On Temp Information: (All information required) Service Size 1 Ph❑3 Ph Size: 3 0 0 A # Meters 1 Old Meter# New Service❑Fire Reconnect[—]Flood Reconnect❑Service Reconnect Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? 0 Y MN Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments "Road 6 o PROJECT / ZONING-DATA m a LLa za TAX MAP # 1000-22-05-12 Z z m a 1 ZONING DISTRICT R-40 CONFORMIN6 0 3 uai g o \� a j w 0 x W cm NN 1 LOT AREA 0A ACRES i a W LL I c zaoW"m'a \` QwF JZz n05 I \ O x a >w 0 0 0 O APPROVED AS NOTED N w_w iiWm�¢a zw000= 5-31-2+ `7 N V__Z DATE;.i B.P.;It 50 '� � s o z a a s \ FEE f/�a= BY: oLLwQ� xw -zo z w z o a w \ a z2 oQ�w i NOTIFY BUILDING DEPARTMENT AT a w 0 631-765-1802 SAM TO 4PM FOR THE Z U fm O U x O x O Co Q �U Q Q d 6 x FOLLOWING INSPE6TIONS: FOUNDATION=TWO REQUIRED FOR POUREDFONCRETE I v ' ROUGH-FRAMING&PLUMBING EXISTING I POOL HOUSE INSULATION N I I BECOMPLETE FOR C.O. -- ' U ALL CONSTRUCTION SHALL MEET THE EX15TI NO ® ' REQUIREMENTS OF THE CODES OF NEW —j m I1N Qoo ROUND� YORK STATE. NOT RESPONSIBLE FOR I DESIGN OR CONSTRUCTION ERRORS U C I , — Q I COMPLY WITH ALL CODES OF a N R YORK STATE&TOWN CODES JRED AND CONDITIONS OF Q EXISTING ��n p/���� sou1H01.nT�Us 2 STORY I �, mw I 26.6 DWELLING PROPOSED 'OENERAC I I ILYUM 26KW' GENERATOR ON Iswmwc CONCRETE PAD I � M W � AC CONDENSORS 0 >: 1 ELECTRICAL o 0 z Additional EXISTING I ,�.�, INSPECTION REQUIRED -j U) g LU 1 DRIVEWAY 1 Certafication m Lo o o May Be Required. o I I oyU A'r` 6:• o W �----- -- ----------_----- -—- -_-__� 561 o20'OO"E 1151.00, _ N W I L L O W D R I V E PROPOSED SITE PLAN SCALE: I'=50'-0" ❑ a (') 6nMYrmml,µg�m'vel Ort�m letr6 sn6v6�tWsa.vYCM,rA9v nt 4Y M!*�amwm,wa)aeu¢Sva+,r2mrrta,Vm4num WD"TG 4®4W¢l N6 fv•lN.M[^W�[am!.H 1®WOTBa11104i1•rlRa"IM06<m,0 ra6r.Al a96on6 SNK•Wn WIELw•m Wd 9aK•ve�SW"WA24.c 9utt•Or 6EW®0®� mt mrx(�)�m[�NN • • K R6n,ra od M WN•c,viu®um a w!m,q(W ve sA2 mlos�GClfanir•¢K/m!lioW mtrum,ulAD N%b+.,p W D¢A v M Lagm v4rFu@a mIT4W6,Y¢n0!xu9vipf W 4'OSfu.wfPYID•a Sl•�pl OetIS(!1 D!lNRll a R![3 M.loVC ruo6 6'a <aq Ymmr,m¢M�¢Iri 16l al9ir Wmwr,rartV®r4W mMw. a� 400 Ostrander Avenue,Riverhead,New York 11401 te1.C 31.TZf.T303 fax.631.=7.0144 admire®youngenginBeringLom N 41t#t0� 5�44� Howard r1 Young,Land Surveyor 11iomos G.r olpert,Professional Engineer Douglas E.Adam,Professional Engineer Daniel A.Weaver,Lend Surveyor c a SITE DATA w � AREA=4g133 SQ.FT. •SUBDIVISION-°HIGHPOINT ATEAST MARION,SECTION 1 FILED IN THE OFFICE OF THE CLERK OF SUFFOLK COUNTY ON JAM H.1984 AS FILE NO.7680. S WSF QQ S612 , �Opo o� awF ti o� oC' ryp , �6d,f f WS - r4 20 W+� Jn Lot 12 �'' s3 ae6• R. Subdivision- "Highpoitrt at East Marion,Section 1" 6q•99• SURVEYOR'S CERTIFICATION WSF O 0� *WE HEREBY CERTIFY TOJOHN BLETSAS &MARY BLETEAS 4,14'aW ti t R THAT THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE CODE OF W� d 6 PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK STATE f $ad 31� dux •or .a ASSOCIATION OF PROFESSIONAL LAND SURVEYORS. �s• �� �k p TF-OpN h �F ARD �/I, rO.f g Q HOWARD W.YOUNG,N.M.L.S.NO. B93 C''v 00 orj ; DANIEL A WEAVER,N.YS.LS.NO.50M Z' D SURD ' Go, "per P�o SURVEY FOR JOHN BLETSAS &'KATHY BLETSAS ! Q LOT 12"HIGHPOINT AT EAST MARION,SECTION P) LL at East Marion,Town of Southold s Suffolk County,New York WSW FOUNDATION LOCATION SURVEY County Tax Map um(ria 1000 se tin '22 swa 05 Coe 12 g \ FIELD SURVEY COMPLETED AUG.01,2023 MAP PREPARED AUG.02,2023 Record of Revisions \ REVISION DATE LEGEND C CC =CONCRETE CURB S CH =CHIMNEY CMF =CONCRETE MONUMENT FOUND - CMS =CONCRETE MONUMENT SET m 40 0 20 40 Bo 120 i WSF WOOD STAKE FOUND _ - WSS =WOOD STAKE SET g • =END OF DIRELTION/DISTANCE Scale:P 40' JOB NO.2023-0094 1 OF 1 DWG.2023_0094_foundationjoc •i ' GENERAC° 26 kW GUARDIAN° SERIES Residential Standby Generators Air-Cooled Gas Engine 0105- Standby Power Rating ' INCLUDES: G007290-01 G007291-0(Aluminum-Bisque)-26 kVV 60 Hz • True Power'" Electrical Technology • Two-line multilingual digital LCD Evolution'"" controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wi-Fi®connectivity • System status&maintenance interval LED indicators -;� • Sound attenuated enclosure • Flexible fuel line connector _ p • Natural gas or LP gas operation GENERAC'.' • 5 Year limited warranty • Base fascia • Listed and labeled for installation as close as 18 in(457 mm)to a I structure.' 'Must be located away from doors,windows,and fresh air intakes and in ON O n accordance with local codes. us or CLISTEDus `-'�U EST eke Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER'"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS:One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. W GENERAC Qga s 4 p uP R O M I S Eb,...• MobJc GENERAC' 26 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown'system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unitthat operates 25%more efficiently than a revolving armature generator. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution`" Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC� 26 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERACm 26 kW Specifications Generator Model G007290-0 G007291-0 (26 kW) Rated maximum� continuous power rapacity(LP) � 26,000 Watts' Rated maximum continuous power capacity(NG) _ 22,500 Watts' Rated maximum continuous load current—240 volts(LP/NG) 108.3/93.8 of ' Total Harrnonic Distortion Less than 5% Main line circuit breaker 110 amp Phase �w 1 --� Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 �Ba eft ry requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum- Unit weight(lb/kg) _ 518/235 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 231t(7 m)with generator operating at normal load" 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test"low-speed exercise mode** 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number r of cyjind`ers 2 Displacement 999 cc Cylinder block Aluminumw/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio - 9.5:1 Starter 12 VDC Oil capacity including filter '' • Approx.1.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas ft3/hr(m?/hr)1/2 Load 188(5.32) I Full Load 333(9.43) i Liquid propane It3/hr(gal/hr)[Uhr] ))[ 1/2 Load 75(2.06)[7.78] Full Load 132(3.63)[13.73] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49--2.99 kPa)for LP gas. For BTU content,multiply 0/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD _ Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-wwekly,or Monthly selectable exerciser. MANUAL Stan with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard RUr/AlamdMaintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). j Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger FaulUMissing AC wa_rnmg Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard LAutomatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard �afety Fused/Fuse Problem Protection __ Standard �----� Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard ,Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown _ _ _ Standard ^^� High Engine Temperature Shutdown Standard �Intwmal FaulVlncorrect Wiring protection �Y� Stwndard �_� Common external fault capability Standard Field upgradable firmware �� Standard Rating definitions—Optional Standby:Applicable for supplying backupp' poer forth duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating.(All ratings in accordance with 8S5514,ISO3046,0L2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level and approximately 1% for each 10°F(6°C)above 60°F(16°C)."Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergencyapplications. GENERACO 26 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007291-0(26 kW) " • Intelligently manages up to four air conditioner loads with no additional hardware. INo,of poles 2 —� Current rating(amps) 200 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Voltage rating(VAC) 120/240,10 with Smart Management Modules(SMMs). Utility voltage monitor(fixed)* • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% -Dropout 65% • Main breakers are rated for 80%continuous load. iReturn to Utility' Approx.13 sec • 2-pole,250 VAC contactors. ETL or UL listed Standard • Service equipment rated,dual coil design. Enclosu'retype NEMA/UL3R • Rated for both aluminum and capper conductors. Circuit breaker protected 22,000Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weeky,or monthly Dimensions 200 Amps 120/240,1ra Open Transition Service Rated Height Width H1 H2 W1 W2 Depth H2 HI in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 1 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug -DEPTH- -W2- 250 MOM-#6 350 MOM-#6 210-#14 GENERAC� 26 kW Available Accessories 04 Model# Product Description G007101-0 Battery Pad Warmer�iPad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- lessary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer armer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where (heavy icing occurs. 1 ' of G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lockout a single large electrical load that may not be Contact Kit (needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured lappearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paintto correctly maintain ortouch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a lGenerac automatic standby generator(oil not included). G007009-0 LTE LP Tank Fuel Level The LTE enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the LP Monitor tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-413 LTE Mobile Link Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. G007301-0 High Altitude Kit A high altitude kit may be required when operating over 2,000 ft(610 m)above sea level per U.S.EPA regulations.Op- erating the engine with the incorrect engine configuration at a given altitude may increase emissions and decrease fuel efficiency and performance. Dimensions & PCs Model UPC 637.6 mm [25.1 In, [48.0 In] G007290-0 696471087307 G007291-0 696471087314 727.2 mm [28.6 in] 99�� i 0 0 O 648 mm 1232 mm [25.5In] 148.5 im LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com 0-.2022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0002026894 Rev.D 09/19/2022