Loading...
HomeMy WebLinkAbout49315-Z of soulyo`o Town of Southold * P.O. Box 1179 io 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 45693 Date: 11/01/2024 THIS CERTIFIES that the building ACCESSORY Location of Property: 2095 Nassau Point Rd Cutchogue, NY 11935 Sec/Block/Lot: 104.-13-3 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 03/15/2023 Pursuant to which Building Permit No. 49315 and dated: 05/30/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to: Little Ducks Realty LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 49315 7/2/2024 PLUMBERS CERTIFICATION: th ize Signature Co TOWN OF SOUTHOLD aye BUILDING DEPARTMENT TOWN CLERK'S OFFICE co oy • o�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49315 Date: 6/30/2023 Permission is hereby granted to: Little Ducks Realty LLC 100 Davids Dr Hauppauge, NY 11788 To: install generator as applied for. At premises located at: 2095 Nassau Point Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 104.-13-3 Pursuant to application dated 3/15/2023 and approved by the Building Inspector. To expire on 11/28/2024. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $23 5.00 Building Inspector ho��OF SO!/l�ol 0 Town Hall Annex . Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 971-0959 �� • �o sean.devlinl'a�town.southold.ny.us c4UNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Little Ducks Realty LLC Address: 2095 Nassau Point Rd city:Cutchogue st: NY zip: 11935 Building Permit#: 49315 Section: 104 Block: 13 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE'NATIONAL ELECTRIC CODE Contractor: Electrician: LC Electric License No: 38043ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 400A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 38kW Kohler Generator w/400A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: July 2, 2024 S.Devlin-Cert Electrical Compliance Form �o�aOF SOUIyo� * ' TOWN OF SOUTHOLD BUILDING" DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ I/AISULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL bWAV%4P-**o" [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [. ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) . [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL (I P4 r REMARKS: DATE (o�i INSPECTOR I� �I s A, OF 50//l # TOWN OF SOUTHOLD BUILDING DEPT. couff", 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)- [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS:. DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS w � FOUNDATION (1ST) y ------------------------------------ 5 C FOUNDATION (2ND) z gJ o G a ROUGH FRAMING& �'M PLUMBING y W r INSULATION PER N.Y-. STATE ENERGY CODE G FINAL ADDITIONAL COMMENTS zt o IZ3 S e CQ a5 C.0�-. z m �A H . x d b H o�g1)FFO('��oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o a�l� Telephone (631) 765-1802 Fax(631) 765-9502 hops://www.southoldtowmy.gov Date Received APPLICATION FOR BUILDING PERMIT q/� or Office Use Only PERMIT NO. l v Building Inspector: l MAR 15 2023 Applications`arid`forms must be filled out in their entirety:Incomplete_ BUIlOINGOEPT. 4app,Iications wilLnot:°6e=accepted.:Where:the=Applicant;is:notaFie;owner,an_ w- TOWNOFSOUTHOLD Owner's;Authoriiation form.(Page 2)sliall be:completed - .._ , -- ,_ .. Date:3/14/23 Name:Little Ducks Realty, LLC, Christine Paparella SCTM#1000-104-13-3 ProjectAddress:2.0_95_Nassau Point Rd,_Cutchue,NY—11935 Phone#: Co2,; Z` �� - --og Email Mailing Address: �(/l(l�-wyt �/1b1Ij')/l Q,4-, Y-f!J IVY 11-7�0__ CONTACT PERSON:.-_, Name:Nicholas Cunha Mailing Address:100 Davids Dr, Hauppauge,.-.NY 11788 Phone#: 631 201-7685 Email:ncunhq(@-broadwavnqtiona1.com DESIGN°PROFESSIONAL IN FOR.IVIATION:.' - Name:John Gramlich Mailing Address:PO BOX 820, Yaphank, NY 11980 Phone#:(631) 381-1752 Email_jcgramlich@gmail.com -- - - CONTRAC°TOR Name: lO�� Mailing Address: Phone#: Email: _:DESCRIPTION OF.PROP.OSED:CONSTRUCTION_ ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther Generator $40,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes *No 1 1 - PROPERTY.IN FORMATION - _ Existing use of property:Single Family Residential Intended use of property:Single Family_Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_4��-� _ - � this property? ❑Yes RNo IF YES, PROVIDE A COPY. "R"check Box Afteraead'ing: The owner/contractor/design.professional is responsible:f_or'all:iJ�einage'and storm-wafer:issues'_as:proviiled°6y _3 _ -- -Chapte?23fi of tlie'.T-own.Code APPLICATION=IS=HEREBY IVIADE,to`ttie;Building:department focWthe:issuance:of_a:Bull`dmg Permit-pursuanteto-theBu�Idij mg;Zo_ne a-.Ordi—ance.of.th-Town of:5outh'oldi-Suffolk County;New York and other applicable Law's Ordinances o`rsRegulations;:for tfieconstruction of hwldings' L' _ additions;alterations or for removal-o_r•:demolitiomas herein described:TFie applicanYagrees to`comply with.all-applicableaaws,ordinances;building code, •ghousi_ng=cade;andredulations a_nd t- admit authonzed'mspectors on:premises a_nd�in'building(s):for-necessary-inspection:=Falsestat'errients made herein are; ;;punishal5le'asa'Clas_s,.-misdemeanor'pursuanttosgltL :210.45_oftheNewYorkStatePena1UFW.-`. = :" := 77 Application Submitted By(print name):/1�,,4���-(�'i�PCtVC V-0j1 I GL ❑Authorized Agent ®Owner Signature of Applicant: Date: j STATE OF NEW YORK) SS: COUNTYOF s✓(7`o��� ) CAei frf IQ- PQpola//A being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the & AV cl" 41 (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1 day of MA2h ,20 1) NofHotary MES R R11.6 rk PROPERTY OWNER AUTHORIZATION OIR16409ic-State 319eW�Where the a licant is not the owner in Suf►esk ep nty 28,( pp ) n Expires Sep 28,2024 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 F'✓�fEQ� BUILDING DEPARTMENT- Electrical Inspector s k�oy TOWN OF SOUTHOLD O Town Hall Annex- 54375 Main Road - PO Box 1179 00 z Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh(a�southoldtownny.gov seand(Q-southoldtownny.Qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN.INFORMATION (All Information Required) Date: Company Name: Electrician's Name: L.-G l L� r License No.: `���U �j M Iec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) b Name: Address:Cross Street: Street: Phone No.: Bldg.Permit#: 1Pemail: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO —]Rough In [] Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph 73 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame 0 Pole Work done on Service? 0 Y ON Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's , UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV Inst Hot DeHum Transfer HOT TUB/SPADisc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments IWorkers' Certificate of Attestation of Exemption ATE Compensation from New York State Workers' Compensation and/or Board Disability and Paid Family Leave Benefits Insurance Coverage "This form cannot be used to waive the workers'compensation rights or obligations of any party.** The applicant may use this Certificate of Attestation of Exemption ONLY to show a government entity that New York State specific workers'compensation and/or disability and paid family leave benefits insurance is not required. The applicant may NOT use this form to show another business or that business's insurance carrier that such insurance is not required. Please provide this form to the government entity from which you are requesting a permit,license or contract. This Certificate will not be accepted by government officials one year after the date printed on the form. In the Application of Business Applying For: (Legal Entity Name and Address): Building Permit Little Ducks Realty LLC 100 Davids Dr From:Town of Southold Hauppauge,NY 11788-2043 PHONE:631-737-3140 FEIN:XXXXX4986 The location of where work will be performed is 2095 Nassau Point Rd,Cutchogue,NY 11935. Estimated dates necessary to complete work associated with the building permit are from May 2,2022 to April 30,2023. The estimated dollar amount of project is over$100,000 Workers'Compensation Exemption Statement: The above named business is certifying that it is NOT REQUIRED TO OBTAIN NEW YORK STATE SPECIFIC WORKERS'COMPENSATION INSURANCE COVERAGE for the following reason: The business is a LLC,LLP,PLLP or a RLLP;OR is a partnership under the laws of New York State and is not a corporation. Other than the partners or members,there are no employees,day labor,leased employees,borrowed employees,part-time employees,unpaid volunteers(including family members)or subcontractors. Partners/Members: Christine Paparella Disability and Paid Family Leave Benefits Exemption Statement: The above named business is certifying that it is NOT REQUIRED TO OBTAIN NEW YORK STATE STATUTORY DISABILITY AND PAID FAMILY LEAVE BENEFITS INSURANCE COVERAGE for the following reason: The business MUST be either: 1) owned by one individual; OR 2) is a partnership(including LLC,LLP,PLLP,RLLP,or LP)under the laws of New York State and is not a corporation; OR 3) is a one or two person owned corporation,with those individuals owning all of the stock and holding all offices of the corporation(in a two person owned corporation each individual must be an officer and own at least one share of stock); OR 4) is a business with no NYS location. In addition,the business does not require disability and paid family leave benefits coverage at this time since it has not employed one or more individuals on at least 30 days in any calendar year in New York State. (Independent contractors are not considered to be employees under the Disability and Paid Family Leave Benefits Law) I,Christine Paparella,am the Member with the above-named legal entity. I affirm that due to my position with the above-named business I have the knowledge,information and authority to make this Certificate of Attestation of Exemption. I hereby affirm that the statements made herein are true,that I have not made any materially false statements and I make this Certificate of Attestation of Exemption under the penalties of perjury. I further affirm that I understand that any false statement,representation or concealment will subject me to felony criminal prosecution,including jail and civil liability in accordance with the Workers'Compensation Law and all other New York State laws. By submitting this Certificate of Attestation of Exemption to the government entity listed above I also hereby affirm that if circumstances change so that workers'compensation insurance and/or disability and paid family leave benefits coverage is required,the above-named legal entity will immediately acquire appropriate New York State specific workers' compensation insurance and/or disability and paid family leave benefits coverage and also immediately furnish proof of that coverage on forms approved by the Chair of the Workers'Compensation Board to the government entity listed above. SIGHERE Signature: Date: 3�/��Z3 ,G�^,�,,4,tyr4 ;,y;� 'v'K.�4��- a. r' :>:ys".. `. .JS '�y,; :./"�.,)s-�i�'�<✓ .,i�ti /�., 1yY - ....'... ..'C >; .R,;;?" ,,>�i(ti: ,�. :t�'` e _rC"L: .\X•` �< •i.:'.,'i' '` ;r"., +c \'"?.:'fit "-, —,.�'},_? '%`r, yam. �Egemptiori�,Certlfcate�Numl%r` �-r� �` r...�._�.��r � � ,.,-.�T�•;`°z:��'•�:.�� ,�. �,, �:= ,. .�,,,� a•,� � .,^,,. �.,•y. ,_.�. r.,moo t.eY-,`,j J• 'i.?".,r.' .%'�,.r:X.�_y�•�,,• � "f w'C✓':`3: .i.,. .-� T.:.`.<`,:•-.,..%'h..{,�-�:`-'�••• `�,'.•r`''':i •��" �'� ``.��i`" Z'�/..."i`�?�f�4 ,' `'��'i•,:.T� 'K�\'`.v, ;. 4. `-�S N y�ti Y�'". 1/`s•� ti: _ q_ �, ':� .Y da .. 7, `� ,� �: � �.. '� s •:�.,^:.�`,"�...'r`� �� r','e'.y .?r ram., 4. ;.,, ;.'::� ., `:<. ..�ter;"�:';�'� .�.?;.��,; �....;�,•,rti.•,-,t... ,,.' ,,,...:k..�.,��� �,. ;'�'� ,�-•r'�-1` "� "s:_;�.r'" �. T .�F'�,.+r�,•- �:%•..,^'s..TM..r .ia�:,,.- .�.t,, a,,._ .t rs: ;, w.�.:�.i'�.,.�:t. �.�"�y' +_�+"•7i�.,,-.�;�:__.. �'`�'._:; Y�r_ •ice ?�_.__��'._.w..,.'.••• .f� .._.Ci::�,_..._.�.� ..••4;. .sx' CE-200 01/2018 � , v r 1 I�1 PAPARELLA RESIDENCE WL _ ►ae= / r41e= ©© /m I ►�.— j ■ V ���� - - ,�`� � �'\,`• ■Illl��s�pin,il Vim• :i�y�7_ �;�lj " �i��'.i/, i/ IJ,G To LKPAPARELLA TANK �. •.r 7 f ... 1-' m s `1. APPR VED AS NOTED DATE: X,�66 B.P.# FEE: *5FBY: NOTIFY_BUILDING DEPARTMENT AT 765-1602 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: . 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING ELECTRICAL 3. INSULATION INSPECTION REQUIRED 4. FINAL - CONSTRUCTION MUST BE COMPLETE F 7R C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S u_u_I F01-01 I OWN PMG BOARD SGUWl aT0WNfiRUSTEES l OCCUPANCY OR USE18 UNLAWFUL WFT lUT:CERTlFlCAT�. �F�OtCUPANCY r KOHLER. Model: 38 R C LC Multi-Fuel Natural Gas/LPG 09001 Standard Features _ 4 KONLER° • Kohler Co. provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are prototype-tested, factory-built,and production-tested. ,a w • The generator set accepts rated load in one step. • A standard five-year or 2000 hour limited warranty covers all systems and components. • Quick-ship(QS) models with selected features are available. See your Kohler distributor for details. ► = • Meets 291 kph (181 mph)wind load rating. • GFCI service outlet installed on the junction box. e+:+ • RDC2 Controller / o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT transfer switch). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying household demand. The Kohler® Advantage o (Digital voltage regulation protects your valuable • High Quality Power electronics from harmonic distortion and unstable power Kohler home generators provide advanced voltage and quality. frequency regulation along'with ultra-low levels of o Two-line,backlit LCD screen is easy to read in all lighting harmonic distortion for excellent generator power quality to conditions, including direct sunlight and low light. protect your valuable electronics. • Engine Features o Powerful and reliable 2.2 L turbocharged liquid-cooled • Extraordinary Reliability engine Kohler is known for extraordinary reliability and o Electronic engine management system. performance and backs that up with a premium five-year or o Simple field conversion between natural gas and LPG 2000 hour limited warranty. fuels while maintaining emission certification. • Aluminum Enclosure • Innovative Cooling System Attractive aluminum enclosure allows installation as close ° Electronically controlled fan speeds minimize generator set sound signature. as 18 inches from your home or small business. • Certifications • Quiet Operation o The 60 Hz generator set engine is certified by the Kohler home generators provide quiet, neighborhood- Environmental Protection Agency(EPA)to conform to the friendly performance. New Source Performance Standard (NSPS)for stationary spark-ignited emissions. o cUL/UL listing,CSA certification standard are available (60 Hz only). o Accepted by the Massachusetts Board of Registration of Plumbers and Gars Fitters. o Meets NFPA 37'requirements for 18 in.offset for installation. • Approved for stationary standby applications in locations Generator Set Ratings served by a reliable utility source. Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 4E8.3 120/240 1 60 38/38 159 38/38 ­159 120/240 1 60 34/34 142 34/34 142 120/208 3 60 38/48 132 38/48 132 4D8.3 127/220 3 60 38/48 125 38/48 J 125 120/240 3 60 38/48 114 38/48 114 277/480 3 60 38/48 57 38/48 57 * 50 Hz options available.Contact your Customer Service representative. RATINGS:All three-phase units are rated at 0.8 power factor.All single-phase units are rated at 1.0 power factor.Due to manufacturing variations,the ratings tolerance is±5%. Standby Ratings:Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads with an average load factor of 80%for the duration of a power outage.No overload capacity is specified for this rating.Ratings are in accordance with ISO3046/1,BS 5514,AS 2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:Altitude:Derate 1.3%per 100 In(328 ft.)elevation above 200 m(656ft).Temperature:Derate 3.0%per 10°C(18°F)temperature above 25°C(TVF).Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Contact your local Kohler generator distributor for availability. G4305 (38RCLC) 6/21 t Alternator Specifications Specifications Alternator • NEMA MG1, IEEE,and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Exciter type' Brushless,Wound-Field • Sustained short-circuit current of up to 300%of the rated Leads:quantity,type current for up to 10 seconds. 4E8.3 4,120/240 4D8.3 12,Reconnectable • Sustained short-circuit current enabling downstream circuit Voltage regulator Solid State,volts/Hz breakers to trip without collapsing the alternator field. Material Class H . Self-ventilated and drip-proof construction. Temperature rise 130°C,Standby Bearing:quantity,type 1,Sealed • Windings are vacuum-impregnated with epoxy varnish for Coupling Flexible Disc dependability and long life. Unbalanced load capability 100%of Rated Standby Current • Superior voltage waveform from a two-thirds pitch stator and One-step load acceptance 100%of Rating skewed rotor. Peak motor starting kVA: (35%dip for voltages below) • Total harmonic distortion (THD)from no load to full load with 240 V 4E8.3(4 lead) 74 (60 Hz) a linear load is less than 4%. 480 V,380 V 4D8.3(12 lead) 120(60Hz) 88(50Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type Residential Powertrain Exhaust temperature at rated kW,dry KG2204T,2.2 L,4-Cycle exhaust, °C(°F) 633(1171) Turbocharged Maximum allowable back pressure, Cylinder arrangement In-line 4 kPa(in.Hg) 7.5(2.2) Displacement,L(cu.in.) 2.2(134.25) Bore and stroke,mm(in.) 91 x 86(3.5 x 3.4) Fuel Compression ratio 10.5:1 Piston speed,m/min.(ft./min.) 310(1016) 258(847) Fuel System Main bearings:quantity,type 5,plain alloy steel Fuel type Natural Gas or LPG Rated rpm 1800 1500 Fuel supply line inlet 1 in.NPT Max.power at rated rpm,kW(HP) Natural gas fuel supply pressure,kPa LPG 47.8(64.1) NA (in.H2O) 1.2-2.7(5-11) Natural Gas 47.6(63.9) NA LPG vapor withdrawal fuel supply Cylinder head material Cast Iron pressure,kPa(in.H2O) 1.2-2.7(5-11) Piston type and material High Silicon Aluminum Fuel Composition Limits* Nat.Gas LP Gas Crankshaft material Nodular Iron Methane,%by volume 90 min. — Valve(exhaust)material Forged Steel Ethane,%by volume 4.0 max. — Governor type Electronic Propane,%by volume 1.0 max. 85 min. Frequency regulation,no-load to Propene,%by volume 0.1 max. 5.0 max. full load Isochronous C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,steady state t1.0% Sulfur,ppm mass 25 max. Frequency Fixed Lower heating value, Air cleaner type Dry MJ/m3(Btu/ft3),min. 33.2(890) 84.2(2260) Engine Electrical * Fuels with other compositions may be acceptable.If your fuel is outside the listed specifications,contact your local distributor for Engine Electrical System further analysis and advice. Ignition system Electronic Battery charging alternator: Lubrication Ground(negative/positive) Negative Lubricating System Volts(DC) 14 Type Full Pressure Ampere rating 90 Oil pan capacity,L(qt.)§ 4.2(4.4) Starter motor rated voltage(DC) 12 Oil added during oil change(on average), Battery,recommended rating for-18°C(0°F): L(qt.)§ 3.3(3.5) -Qty.,cold cranking amps(CCA) One,630 Oil filter:quantity,type§ 1,Cartridge Battery voltage(DC) 12 Oil cooler Remote Battery group size 24 § Kohler recommends the use of Kohler Genuine oil and filters. G4-305 (38RCLC) 6/21 t Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Ambient temperature,°C(°F) 45(113) Engine jacket water capacity,L(gal.) 2.65(0.7) Radiator system capacity,including Voltage:Freq: 60.0 Hz 240V O O O engine,L(gal.) 13.2(3.5) Water pump type Centrifugal �mt3 o O O Fan diameter,mm(in.) qty.3 @ 406(16) Fan power requirements(powered by engine battery charging alternator) 12VDC,18 amps each Operation Requirements Air Requirements 60 Hz 50 Hz The RDC2 controller provides integrated control for the Radiator-cooled cooling air, generator set, Kohler@ Model RXT transfer switch, m3/min.(scfm)t 51 (1800) 51 (1800) programmable interface module(PIM),and load management. Combustion air,m3/min.(cfm) 2.1 (74) 1.8(64) Air over engine,m3/min.(cfm) 25(900) 25(900) The RDC2 controller's 2-line LCD screen displays status f Air density=1.20 kg/m3(0.075 Ibm/ft3) messages and system settings that are clear and easy to read, even in direct sunlight or low light. Fuel Consumption* Natural Gas,m3/hr.(cfh)at%load 60 Hi 50 Hz RDC2 Controller Features 100% 13.9 (492) 11.6 (409) • Membrane keypad 75% 11.4 (404) 9.5 (335) 50% 9.3 (327) 7.8 (275) o OFF,AUTO,and RUN push buttons 25% 5.8 (205) 4.8 (169) o Select and arrow buttons for access to system Exercise 3.4 (121) 2.8 (99) configuration and adjustment menus LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz • LED indicators for OFF,AUTO,and RUN modes 100% 5.6 (197) 4.7 (166) • LED indicators for utility power and generator set source 75% 4.5 (160) 3.8 (134) availability and ATS position(Model RXT transfer switch 50% 3.2 (114) 2.7 (95) required) 25% 2.1 (76) 1.8 (64) • LCD screen Exercise 1.2 (41) 1.0 (35) o Two lines x 16 characters per line * Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP vapor,93 MJ/m3(2500 Btu/ft3) visibility in all lighting conditions LP vapor conversion factors: 8.58 ft.3=1 lb. • Scrolling system status display 9.535 m3=1 kg. o Generator set status 36.39 ft.3=1 gal. o Voltage and frequency o Engine temperature Sound Enclosure Features o Oil pressure • Sound-attenuating enclosure uses acoustic insulation that o Battery voltage meets UL 94 HF1 flammability classification and repels o Engine runtime hours moisture absorption. • Date and time displays • Internally mounted critical silencer. • Smart engine cooldown senses engine temperature • Skid-mounted,aluminum construction with two removable • Digital isochronous governor to maintain steady-state speed access panels. at all loads •_.Fade-,scratch-,and corrosion-resistant Kohler@ cashmere • Digital voltage regulation: ±1.0% RMS no-load to full-load powder-baked finish: • Automatic start with programmed cranking cycle Sound Data • Programmable exerciser can be set to start automatically on any future day and time,and to run every week or every two Model 38RCLC 8 point logarithmic average sound levels are weeks 53 dB(A)during weekly engine exercise and 61 dB(A) during • Exercise modes full-speed generator diagnostics and normal operation. For o Unloaded exercise with complete system diagnostics comparison to competitor ratings,the lowest point sound levels o Unloaded full-speed exercise f are 52 dB(A)and 59 dB(A) respectively* o Loaded full-speed exercise (Model RXT ATS required) All sound levels are measured at 7 meters with no load. • Front-access mini USB connector for SiteTech- connection * Lowest of 8 points measured around the generator.Sound levels at other points around generator may vary depending on installation parameters. • Integral Ethernet connector for Kohler('OnCue(D Plus • Built-in 2.5 amp battery charger • Remote two-wire`start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-305 (38RCLC) 6/21 .5 KOHLER® PhoneKOHL 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Starting Aids§ o Displays diagnostic messages for the engine, generator, ❑ Block Heater,120 V,1 Ph Model RXT transfer switch, programmable interface ❑ Block Heater,240 V,1 Ph module(PIM),and load management device ❑ Oil Pan Heater,120 V,1 Ph o Over 70 diagnostic messages can be displayed ❑ Oil Pan Heater,240 V,1 Ph j • Maintenance reminders § One block heater or oil pan heater is recommended for ambient • System settings temperatures below 0°C(32°F). At temperatures below-1 WC(0°F), o System voltage,frequency,and phase installation of both heaters is recommended. o Voltage adjustment Automatic Transfer Switches and Accessories o Measurement system, English or metric ❑ Model ROT Automatic Transfer Switch • ATS status(Model RXT ATS required) ❑ Model RXT Automatic Transfer Switch o Source availability ❑ Model RXT Automatic Transfer Switch with Combined o ATS position(normal/utility or emergency/generator) Interface/Load Management Board o Source voltage and frequency ❑ Load Shed Kit for RDT or RXT. • ATS control (Model RXT ATS required) ❑ Power Relay Modules(use up to 4 relay modules for each o Source voltage acid frequency settings load management device) o Engine start time delay Maintenance o Transfer time delays ❑ Maintenance kit(includes air filter,oil,oil filter,and spark plugs) o Fixed pickup and dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable interface module(PIM)status displays ( Literature o Input status(active/inactive) ❑ General Maintenance Literature Kit o Output status(active/inactive)- ❑ Overhaul Literature Kit • Load control menus ❑ Production Literature Kit o Load status Warranty o Test function ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty Generator Set Standard Features ❑ Extended 10-Year/2000 Hour Comprehensive Limited Warranty • Aluminum sound enclosure with enclosed silencer • Battery rack and cables Dimensions and Weights • cUL/US listed,CSA certified Overall Size,L x W x H,mm(in.): 1880 x 836 x 1169 • Electronic, isochronous governor (74 x 32.9 x 46.0) • Flexible fuel line Shipping Weight,wet,kg(lb.): 621 (1370) • Gas fuel system (includes fuel mixer, electronic secondary weight includes generator set with engine fluids, sound enclosure, gas regulator,two gas solenoid valves,and flexible fuel line silencer,and packaging. between the engine and the skid-mounted fuel system components) • GFCI service outlet, 120/240 V for customer connection • Integral vibration isolation • Line circuit breaker H • NEC prime mover shutdown switch • Oil drain extension • OnCue®Plus Generator Management System W� L • Operation and installation literature • RDC2 controller with built-in battery charger NOTE:This drawing is provided for reference only and should not be • Standard five-year or 2000 hour limited warranty used for planning installation.Contact your local distributor for more detailed information. Available Options DISTRIBUTED BY- Controller Accessories ❑ Lockable Emergency Stop(lockout/tagout) ❑ Programmable Interface Module(PIM) (provides 2 digital inputs and 6 relay outputs) Electrical System ❑ Battery ❑ Battery Heater ❑ OnCueg Plus Wireless Radio Kit ©2021 Kohler Co.All rights reserved. G4-305 (38RCLC) 6/21