HomeMy WebLinkAbout50920-Z `pSUFFo�,��p Town of Southold 10/9/2024 O G y� P.O.Box 1179 o • ..� 53095 Main Rd yfj�l �ao�. Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45642 Date: 10/9/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2045 Long Creek Dr., Southold SCTM#: 473889 Sec/Block/Lot: 55.-7-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/15/2024 pursuant to which Building Permit No. 50920 dated 7/10/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar to existing single family dwelling as applied for. The certificate is issued to Russell,Mahlon&Kim of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50920 9/11/2024 PLUMBERS CERTIFICATION DATED 00 Signature �SVFFot,� TOWN OF SOUTHOLD BUILDING DEPARTMENT y a TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50920 Date: 7/10/2024 Permission is hereby granted to: Russell, Mahlon 2045 Long Creek Dr Southold, NY 11971 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 2045 Long Creek Dr., Southold SCTM #473889 Sec/Block/Lot# 55.-7-5 Pursuant to application dated 6/15/2024 and approved by the Building Inspector. To expire on 11912026. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-RESIDENTIAL $100.00 Total: $325.00 Building Inspector SOUT�O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 sean.devlinCa�town.southold.ny.us DU , BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mahlon Russell. Address: 2045 Long,Creek Dr city:Southold st: NY zip: 11971 Building Permit* 50920 Section: 55 Block: 7 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy LLC License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel . A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 11.9kW Roof Mounted PV Solar Energy System w/ (28) JKM425N-54HL4-B Modules Enphase Combinerw/ (3)220Breakers & (1) 215 Breaker, 60A Fused Disco, 60A Unfused Disco Notes: Lineside Tapped Solar r Inspector Signature: Date: September 11, 2024 S.Devlin-Cert Electrical Compliance Form Copy OF SOUlyolo # TOWN OF SOUTHOLD BUILDING DEPT. • io 631-765-1802 1-:NSPECTION- I FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND. [ ] SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL4otl�✓ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION :[ ] FIRE RESISTANT CONSTRUCTION [ . ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION .[ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR - �o��oF soUlyO6 sEf/:T e�/�i # TOWN- OF SOUTHOLD BUILDING DEG . coU 631-765-1802 INSPECTI-ON . [ ]: FOUNDATION 1ST/-REBAR [ ] ROUGH PLBG. [ ]. FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [. ] CODE VIOLATION /[ ]' PRE C/O [ ]. RENTAL REMARKS: ftb-r(I e-r I YL 0 0 /Ut\La c� j Is 1n Ptje- . =cu,6 c — Z too T / 2 DATE 19 12,L4, ANSPECTOR Page 1 of 2 Current 08/06/2024 Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 G S Q U Subject: Structural Certification for Installation of Residential Solar AEG 2 9 2024 9 Job: KIM & MAHLON RUSSELL Bu11d`ngDePa Town of Sov�{otdt Project Address: 2045 Long Creek Drive, Southold, NY, 11971 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof:N/A Exp:09/30/2025 OF NEWy A. (,qo0 Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com 106793 F NP Signed on:08/06/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 32 degrees and has a max beam span of 17.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 37 degrees and has a max beam span of 26.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 26 degrees and has a max beam span of 23.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 1 of 2 2 Current 09/09/2024 S E P 1 1 2024 Renewables Element Energy LLC Engineering Building Department 7470 Sound Avenue, Mattituck, NY, lqut ®uth®ld Subject: Structural Certification for Installation of Residential Solar Job: KIM & MAHLON RUSSELL Project Address: 2045 Long Creek Drive, Southold, NY, 11971 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A 1 Exp:09/3012025 oF NEW 1, A. Current Renewables Engineering Inc. Professional Engineer info 9currentrenewableseng.com 2 106793 F NP Signed on:09/09/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 32 degrees and has a max beam span of 17.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 37 degrees and has a max beam span of 26.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 26 degrees and has a max beam span of 23.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com CZSYS6 ELEMENT ENERGY LLC. 7470 SOUND AVENUE, MATTITUCK, NEW YORK, 11952 Date: 9/9/2024 Customer Name: KIM&MAHLON RUSSELL Project Address: 2045 LONG CREEK DR, SOUTHOLD, NY 11971 REV-2 Outlined below are the list of rejections received from the plan checking department. Each revision item has a response, outlining our corrective action for your rejection,these will be marked in red in this letter and will also have red revision clouds on the permit packet/plan set. If you have any questions, please reach out. 1) Update combiner part#to Enphase X-IQ-AM1-240-5. -Combiner box part no. has been changed. 2) Update fuse to 60A fuses. - Fuse size has been changed to 60A. 3)Add unfused AC disconnect. -Unfused AC disconnect has been added and location of equipment has been changed. S E P 1 1 2024 I30ding Depav1ment Town of outhold 450couo Current Rene abler Engineering Suffolk County September 30, 2024 Subject: Post Installation Approval Letter C Job Name: KIM & MAHLON RUSSELL Project Address:2045 Long Creek Dr, Southold, NY 11971 0CT ' 7 2024 Building Department Town Of Seu`hold To Suffolk County I have reviewed the solar energy system installation in the subject topic on 09/30/2024.The units have been installed on in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Suffolk County, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, SEI/ASCE 7-16, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property, and public welfare. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. Exp:09/30/2025 Sincerely, ��OF AEG{r yO; * ��0 qo� yt Professional Engineer r 4, Current Renewables Engineering 2 0 info@currentrenewableseng.com `r�`� 106793 Signed on:09/30/2024 1760 Chicago Ave Suite J13,Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) cs --------------------------------- ---- FOUNDATION (2ND) ------------- ROUGH FRAMING& PLUMBING INSULATION PER N. Y. STATE ENERGY CODE jr Vw FINAL lr% ADDITIONAL COMMENTS Wk 0 1 15 ......------ -------- ---------- ---------- I ono`` �c�Gy TOWN OF SO'L THO LD -BUILDING DEPARTMENT w =j Town Hall Annex 54375 plain Road P. ®. Box 1179 Southold, PY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 httl2s:Hwww.southoldtownny.l?ov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only / PERMIT NO. J 0 //�90 Building Inspector: Applications and forms,must be filled out in theirentiretY.Incomplete applications will not be accepted. Where the Appkant us rant the owner,,an OwlrseesAuthorization form(Page 21 shaill be completed, Date: S Q ja�i OWNER(S)OF PROPERTY-. Name: N&JI lty, 1ZVt1S-C- n SCTM#1000- �� 0V ' 0-7 00 - 00-5 0\2o Project Address: a 0 y S LOY1 CYIIS` Dy- ' _ h� n 1 U. 11 �-7 1 Phone#: (a,3 1- 3 8 2 v -7®q I Email: �� b�- Mailing Address: a u q{ LOYV /1„K C� �Y,. �b l * - l L Z COINTACr PERSON. �,► C P V Name: Lo rrA iV n<r -b D Pe% i,— MailingAddress: -74�® SouAd a Mo-44mck . Phone#: (D .-7&7 8 Email: pe�ri4 43 e, , DESIGN PROMS9cDN AL INFORM,oATIOM Name: I Mailing Address: Phone#: Email: Name: E'7' rn ew Mailing Address: Phone#: ® ,-� Email: T y-ei4sq' CO'L's 'sb CDP, DESC9i" N.OF PROP OSEID C ONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ther I ns+e 0 -Sb hxf PV g,�J 54-c-D) [1 , 0J Y W $_- -3 �A 0 Will the lot be re-graded? ❑YesANo Will excess fill be removed from premises? ❑Yes�lUo I 1 PROPERTY INFORMATION Existing use of property: Intended use of property: / Zone or use district in whit remises is situated: Are there any ovenants and restrictions with respect to this property? ❑No IF YES, PROVIDE A COPY. eck Box Aftet�Read ng: The owner/contractor/design professional is responsible for all diainage ah4J.torm water issues as provided by Chapter 236 of the,Town Code.APPLICATION IS HEREBY MADE'to.the Building Department for the issuance of a Building Permit pursuant to the Building Zone Oidinance of the Town of Southold;Suffolk,County,New York and othe%applicable Laws,Ordinances or Regulations,for the construction of buildings; additions,alterations or for removal,or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,:building code,_ housing code and regulations and to admit authorized inspectors on premises'and in building(s)for necessary inspections,,False statements made herein are . Punishable as a Class A misdemeanor pursuant to Section 216.45 of the New York State Penal Law: Application Submitted By(print name):Lorraine ®o Penta ®Authorized Agent El Owner Signature of Applicant: A, A,-,-4h Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk Lorraine ®IPenta being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of '�GL 20 2 V No Wry Public LOUIS J ROMEO Notary Public,State of New York No.01 R06314813 Qualified in Suffolk County PROPERTY OWNER AUTHORIZATION Commission Expires November 17,20.2 6 (Where the applicant is not the owner) I, Ol 10Y) P ki-W-t it residing at_a O q 5 L-onq Cy—,eel(. � ii a ki do hereby authorize !moo rr'er.�-a -z> IOCA=�- to apply on �t��.�•�- En.e..ry y my ehalf toe Town of o thold B it ing Department for approval as described herein. X �=? -76 Owner's Signature Date hAlAw 1>i -Rus�eCL Print Owner's Name 2 ®S�FF04 BUILDING DEPARTMENT- Electra al ts r T®�/N OES 4 o Town Hall Annex - 54375 j�h,Road - PO 50q 179 i � + � A Southold, New Yo C �19X7�-R95'� �Ol ��o � Telephone (631) 765-1802 . (631) 765-950 ,� �. _. = 7 t rogerr(aD-southoldtownny.gov -- seand(&spl ttotiftownnY;gov . APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Zv Company Name: 61CMcA4 E n e,!,- L � Electrician's Name:-Jo�+mc_-, M >i iny)o e License No.: �, �� e Elec. email: Pecmo+,5 Elec. Phone No: -)o�rI33 [59I request an email copy of Certificate of Compliance Elec. Address.: o ,39 wl- OLVt, JOB SITE INFORMATION (All Information Required) Name: l n Address: a 0 1--on Cy-c-Ck_ D�' u lN H l a� Cross Street: L.—,rLl , Phone No.: (631 .51 S a '7 0 L' I Bldg.Permit#: �0 email: 9f,,>r-M4 Tax Map District: 1000 Section:0 S5. 00 Block: O?. b e Lot: 60 5.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Lk ` l W Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO -]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ® NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# [-]New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame Pole Work done on Service? Y MN Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments o IN workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that came 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTiTUCK,NY 11952 1 c.Federal Employer Identification Numb of Insured Work Locatior,of Insured(Onlymquired iftoverage is speciRcaulyijmded to 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Bolder) ShelterPoint Life Insurance Compafry TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"Ia" SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides fits following benefits: ® A Both disability and paid family leave benefits. HS.Disability benefits only. C.Paid family leave benefits only. 5. Policycovers. ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees:- Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By (Signature of insurance carriers authorized representative or NYS licensed Ireurance Agent of than kawarrce carrier) Telephone Number 516-829-8100 Name and Tice Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authwrized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate Folder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plants Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If Box 46,4C or 5B have been chedleM State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance poricies and NYS licensed insurance agents of those insurance carriers are authorized to issue Fcrm 08-120,1.Insurance brokers are NOT authorized to Issue this form. D8.120.1 (12-21) CERTIFICATE OF LIABILITY INSURANCE °" '"""7'/12 023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endomemen4s). PRODUCER CONTACT ROBERT S.FEDE INSURANCE AGENCY PHONE 23 GREEN STREET,SUITE 102 No Ex* A1C Ho: E-NWL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSU AFFORDING COVERAGE NAIC B INSURER A:ATLANTIC CASUALTY INS.CO. 624210 INSURED Element Energy LLC INSINSUR ER ERS' DBA ELEMENT ENERGY SYSTEMS UPERD:GENERAL STAR KM INSUR • 7470 SOUND AVENUE MATTITUCK,NY 11952 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR no LTR TYPE OF INSURANCE POLICYNUMBER NIDD CY EFF POLICY YYVI r LIMITS Ix I COMMERCIAL GENERAL LIABILITY L14B0036873 EACH OCCURRENCE $ 3,000,000 A X X 7/14/2023 7/14/2024 CLAIMS-MADE ©OCCUR PREMISES JFa aco rance S 100,000 WIA389203B MED EXP{ cm person) $ 5000 X Contractual Lia 7/19/2022 7/19/2024 PERSON a AOv INJURY s 3000000 GEML AGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE 3 3,000,000 POLICY X PRO.JECT LOC PRODUCTS-COUPIOP AGG $ 3000 OTHER: $ AUTOMOBILE UABRA Y EOht tote SINGE LMIT f ANY AUTO OWNED SCHEDULE BODILY INJURY(Per person) $ AUTOS ONLY AUTOS BODILY INJURY(Per accieefl) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY :LQV $ s UMBRELLALIAB OCCUR EACH OCCURRENCE $ F1 E%CESSLWB CLAIMS-MADE AGGREGATE $ QED If I RETEMiCN$ $ WORKERS COMPENSATION 124494445 AND EMPLOYERS'LIABl1TY YIN N 7/13/2023 7/13/2024 PTAT ER ANY FROPRIE RIPARTN -CUTIdE E L EACH ACCIDENT $ 1 000 000 $ OFRCERANEMBEREXCLUCED?DED? � NIA IMUNIA 1InNFq EL DISEASE-FJIEMPLOYE $ If yes,describe under DESCRIPTION OF OPFJRATIONS babe EL DISEASE-POLICY LIMIT s —I nno Mn NY State DBL DOL567527 V01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS i VEIICLES(ACORD 101,AddlIfonxl Remarks Sakedule,may be aftAe 4 9 more space in roWre#) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHCR=REPRESENTATNE 1?015. S- Fed,-, ©1988-2015 ACORD CORPORATION. All rights reserved. ernon�e»ntA/na� Th-Ae-non...... ...a 1,.,. ......:a... .... ,.r,�..s Ar+ncn /l NYSIF Now York State Insurance Fund PO Box 66699,Albany,NY 122C6 I nysif.com CERTIFICATE OF WORKERS'COMPENSATION INSURANCE (RENEWED) VIA ^^^"A" 8233366" ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER T CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07/1312023 TO 0711312024 7111/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WESSITE AT NTTPS:IPJVWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING OCCUPANCY OR ' k-r%.. APPROVE AS NOTED USE IS UNLAWFUL DATE:1,•,��'a B.P.# sa WITHOUT CERTIFICATE FEA BY:' OFF OCCUPANCY NOTIFY BUILDING DEPARTMENTAT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION COMPLY WITH ALL CODES OF a. FINAL-CONSTRUCTION MUST NEW YOR STATE&TOWN CODES BE COMPLETE FOR C.O. AS REQU ED AND CONDITIONS OF ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW SOUIHOI OTOWN DA YORK STATE. NOT RESPONSIBLE FOR �pUf i'�OLpIpINN PLANNING BQARD DESIGN OR CONSTRUCTON ERRORS N.Y.S.DEC SOUTHOLD HPC SCHD VNS4g==REQUIRED RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. , ' Page 1 of 2 -k is Current 05/12/2024 �P � �;�'� Renewables Element Energy LLC `� r 1,`,,� Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: KIM & MAHLON RUSSELL Project Address: 2045 Long Creek Drive, Southold, NY, 11971 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 ��-Of NEW 1- Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com FDA 106793 F Na Signed on:0 5/1 212 0 24 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 32 degrees and has a max beam span of 17.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 37 degrees and has a max beam span of 26.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 26 degrees and has a max beam span of 23.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Exp:09130/2025 ROOF MOUNT SOLAR PERMIT PACKAGE ��0FNEW 1 A. KIM & MAHLON RUSSELL 11 .900 KW DC GRID TIED PHOTOVOLTAIC SYSTEM r � F` 2 106793 2045 LONG CREEK DR, SOUTHOLD, NY 11971 Signed on:05/12/2024 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES: THESE DRAWINGS ARE SUBJECT TO THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC COPYRIGHT PROTECTION BY US LAW_ 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY REPRODUCTION IN ANY FORM IS POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION EXPRESSLY FORBIDDEN WITHOUT PRIOR 2020 NEW YORK STATE BUILDING CODE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES WRITTEN APPROVAL FROM CURRENT RENEwABLES ENGINEERING INC. 2020 NEW YORK STATE RESIDENTIAL CODE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED 2020 NEW YORK STATE MECHANICAL CODE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 2017 NATIONAL ELECTRICAL CODE UNDERSIGNED Current 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 ( 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT Engineering 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL j JURISDICTION AND THE UTILITY IS OBTAINED CURRENT RENEWABLES THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, ENGINEERING INC. MECHANICAL,OR BUILDING ROOF VENTS 1760 CHICAGO AVE SUITE _ AHJ:TOWN OF SOUTHOLD 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS J-13.RIVERSIDECA92507 THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PHONE(951)-405-1733 ( 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED WWWARENG CO CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S CONTRACTOR INFO 1✓` INSTALLATION INSTRUCTIONS" 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA uM UTILITY METER PM PRODUCTION METER REGULATIONS • 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" ® -..- SP MAIN SERVICE PANEL INv INVERTER 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY COMBINER SUB PANEL �����£ BUILDING INFORMATION ❑ GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. u C SUB 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. AC DISCONNECT LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE ELEMENT ENERGY LLC. 2 STORY HOUSE SINGLE FAMILY RESIDENCE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF 7470 SOUND AVENUE,MATTITUCK, MODULE REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. NEW YORK,11952 EIQ IQ CONTROLLER 2 18 CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" PH:(631)779 7993 CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U ROOF OBSTRUCTIONS ABOVE ROOF SURFACE. services@e2sys.com ATT BATTERY Licence-ME-52689 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE 36"ACCESS PATHWAYS RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN (MASTER ELECTRICIAN) APN : 1000055000700005000 QH Q.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH Licence-HI-67461 18"ACCESS PATHWAYS OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT (SUFFOLK HOME IMPROVEMENT) SHEET INDEX AC ESS DISCONNECT 20 MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, KIM& MAHLON RUSSELL ROOF ACCESS POINT STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO L c LOAD CENTER THE PURPOSE INTENDED: 2045 LONG CREEK DR, PV-1.0 COVER PAGE - RAIL SOUTHOLD,NY 11971 PV-2.0 'SITE PLAN RAFTER a LOT NO. :- 0.84 ACRES SEPTIC TANK PV SUMMARY ATTACHMENT SYSTEM SIZE PV-2.1 ,ROOF PLAN sss LEACH LINES (KWDC) STC 425 X 28 =11.900 MAIN BREAKER PTC 398.1 X 1 26 =11 147 PV-3.0 STRUCTURAL BE ENCLOSURE PROPANE TANK WIND SPEED 128 SYSTEM SIZE 960 �240 PV-4.0 ELECTRICAL 3LD TS AUTOMATIC TRANSFER WELL SNOW LOAD 25 (KWAC) g, 02 INK0 SOLAR PV-4.1 ELECTRICAL SLD SWITCH O MODULES 28 1KM425N-54H B L4- Z POWER LINES EXPOSURE CATEGORY C PV-4.2 ELECTRICAL PHOTOS MIC RO RO-Nv OTv zs © PERMANENT ANCHOR INVERTER ENPHASE IQ8MC-72-M-US NO LADDER ACCESS STRUCTURAL NOTES : ONG ISLAND POWER AUTHORITv PV-5.0 BOM (STEEP GRADE UTILITY �UPA) TC TEMPORARY ANCHOR OR GROUND LEVEL 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF PV-6.0 SIGNAGE & PLACARD OBSTRUCTIONS) THE ROOF FRAMING SUPPORTING THE PROPOSED PV INSTALLATION ONLY. KIL INSTALLER LADDER 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. PV-7.0 SPECS+ As GAS SHUT OFF 3. PV MODULES, RACKING,AND ATTACHMENT COMPONENTS MUST FOLLOW Rev Description Date MANUFACTURER GUIDELINES AND REQUIREMENTS. A INITIAL DESIGN 5/11/zoz4 S❑ STUB-OUT Hzo WATER SHUT OFF 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT ® SKYLIGHT FOR ADDITIONAL INFORMATION. O SERVICE DROP 5. PRIOR TO COMMENCEMENT OF WORK.THE SOLAR INSTALLER SHALL PROJECT# 9471 VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE DATE DRAWN 5/11/2024 RESTRICTED ACCESS JUNCTION BOX DRAWN BY ER E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND CONDUIT FOLLOWING:2x10 RAFTERS @ 16"OC SPACING WITH MAX UNSUPPORTED SHEET# P11-10 SPAN EQUAL OR LESS THAN 26 FT. TITLE COVER PAGE R324.6.1 PATHWAYS: WIND SPEED 128 Exp:09/30/2025 NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND SEPARATE ROOF PLANES, SNOW LOAD 25 Of NEW yO FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. EXPOSURE CATEGORY C 67►_9►► cAll r<Rt A.UTILITY 'P AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR / "�__� �7 UM UTILITY METER �00 4��n DRIVEWAY SIDE OF THE ROOF. PROPERTY LINE FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM _"�__ MSP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE I r CCLI SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING n THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE 4 `� c❑ COMBINER f� OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS � � AC DISCONNECT 106793 WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR BOA MECHANICAL EQUIPMENT. If \ MODULE - R324.6.2 SETBACK AT RIDGE: I ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 , \ Signed on:05/12/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN _ 36"ACCESS PATHWAYS AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. 971-311 V i COPYRIGHT PROTECTION BY US LAW FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 `� 18"ACCESS PATHWAYS REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A FsP (� EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A v ROOF ACCESS POINT WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. RENEWABLES ENGINEERING INC. I R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS C Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED / THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE Renewables AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. I Engineering J NOTES: CURRENT RENEWABLES 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED I ENGINEERING INC. ROOF ACCESS POINT 1760 CHICAGO AVE SUITE ON ACTUAL SITE CONDITION AND \ J-13.RIVERSIDE CA 92507 MEASUREMENTS. I `� / —� PHONE(951)405-1733 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS ROOF OBSTRUCTION WWW.CRENG CO INCORPORATED INTO THE 2017 NEC AND UL I I.11 I I CONTRACTOR INFO STANDARD 1741. 11 3. EXISTING ROOF VENT SHOULD NOT BE If COVERED. ROOF LINE / v & � _1138, a 0 r* E ZSYSA N ' FENCE Q ELEMENT ENERGY LLC. DRIVEWAY 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 ����,• - 1�� w services@e2sys.com Licence-ME-52689 ROOF ACCESS POINT � (MASTER ELECTRICIAN) / U (SUFFOLK HOME'IMPROVEMENT) If KIM & MAHLON RUSSELL 0 2045 LONG CREEK DR, C0 J SOUTHOLD,NY 11971 i � PV SUMMARY SYSTEM SIZE _ STC 425 X = 1.900 28 • •. 4 (KWDC) �• / PTC 398.1 X 1 26 = 1.141 j SYSTEM SIZE (KWAC) : 8.960 a240 112' 11 " 11NKO SOLAR .-I MODULES 28 1KM425N-54HL4-B MICRO-INV.QTY 28 MICRO :INVERTER ENPHASE IQ8MC-72-M-US � 4 / UTILITY ONG ISLAND POWER AUTHORITY UPA) I I / I ' PROPERTY LINE Rev Description Date A INITIAL DESIGN 5111/2024 5 1 O 1►► / PROJECT# 9471 /I { DATE DRAWN 5/11/2024 •.ti.6 SIT PLAN �✓ DRAWN BY ER E 1 SHEET# PV-2 0 TITLE SCALE: 1/32" = 1�-011 SITE PLAN LEGEND Exp.09/30/2025 ARRAY AREA ROOF TOTAL ,�-pF NEW y ARRAY ROOF ROOF AZIMUTH #OF AREA AREA AREA AREA uM UTILITY METER �P RZ A• 0 MODULES (ARSq. A (ARSq. A COVERED BY COVERED BY p0� �4 ARRAY(%) ARRAY(%) SP MAIN SERVICE PANEL #1 232° 14 294.28 4036 7.29 COMBINER #2 142° 8 168.16 4036 4.17 14.58 c❑ #3 142° 6 126.12 4036 3.12 �c AC DISCONNECT \ 106793 NPR, MODULE F - ROOF OBSTRUCTIONS . 36"ACCESS PATHWAYS Signed on:05/12/2024 THESE DRAWINGS ARE SUBJECT TO 18"ACCESS PATHWAYS COPYRIGHT PROTECTION BY US LAW. / REPRODUCTION IN ANY FORM IS ROOF ACCESS POINT EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RAIL RENEWABLES ENGINEERING INC. Ks C RAFTER Current C ATTACHMENT Renewables / Engineerirg CURRENT R LES ENGINEERINGG INC.INC. / 1760 CHICAGO AVE SUITE RIVERSIDE / J-13.RIVERSIDE CA 92507 3 .(951)-4051733 WWW.0/ WWW CRENG—� CONN TRACTOR INFO M a m IN EZSYSA ELEMENT ENERGY LLC. 7470 SOUNDNEW YORK,11 52��UCK, LI.J PH:(631)779 7993 I i I i \ c un w services@e2sys.com Licence-ME-52689 MASTER ELECTRICIAN U Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) ROOF#2 z KIM & MAHLON RUSSELL 0 2045 LONG CREEK DR, SOUTHOLD,NY 11971 PVSUMMARY ' SYSTEM SIZE(KWDC) STC 425 X 28 = 1.900 PTC 398.1 X 28 =11.147 _ (/ _ A SYSTEM SIZE 8.960 0240 MODULES pg 1INKOOLAR KM4 5N- 1M425N-5454HL4$ ROOF#3 MICRO-INV.OTY 26 JINKO SOLAR JKM425N-5HL -B (N28 R 44 MICRo) EN PHASE 1081VIC-72-M-US INVERTER _f UTILITY ONG ISLAND POWER AUTHORITY . I ' Rev Desaiption Date A INITIAL DESIGN 5/11/2024 PROJECT# 9471 DATE DRAWN 5/11/2024 DRAWN BY ER ROOF PLANL ROOF#1 SHEET# PV-2.1 2 TITLE SCALE: 3/32" = 1'-0" ROOF PLAN TABLE 1 TABLE 2 Exp:09f3O/2025 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX of NEW y, NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG A. lq S2 ATTACHMENT IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ROOF 1 32° COMP SHINGLE RAFTER 2X10 16" 64" 24" r � � s3 RAIL IRONRIDGE XR-100 RAIL ROOF 2 37° COMP SHINGLE RAFTER 2X10 16" 64" 2411 ROOF 3 26° COMP SHINGLE RAFTER 2X10 16" 64" 24" yJ'�OA 106793 NP Signed on:05/12/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Aes Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE MODULE J-13.RIVERSIDE CA 92507 PHONE.(951)105-1733 W W W.CRENG.CO S3 CONTRACTORINFO TABLE : PENETRATION rAl S2 GUIDE FOR INSTALL lm ROOF TWO OR MORE ROWS OF PANELS CZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 2.5"MIN.EMBED. ', NEW YORK,11952 I I I I I I I I I I I I I I I I I I ( PH:(631)779 7993 services@e2sys.com I I I I I I I I I I I I I I I I I I Licence-ME-52689 (MASTE (2)-#14 X 3" SELF DRILLING Lic nce-LHI-6R461 (SUFFOLK HOME IMPROVEMENT) STRUCTURAL SCREWS TO I I I I I I I I I I I I I I I s1 EXISTING STRUCTURE I I I I I I I I I I I I I I I I I I I KIM &MAHLON RUSSELL 2045 LONG CREEK DR, ENLARGED VIEW '� sOUTHOLD,NY 11971 STACKED STAGGERED FULLY STAGGERED PVSUMMARY SYSTEM SIZE(KWDC) STC 425 X 28 =11.900 ONE ROW OF PANELS RTC 398.1 1 X 1 28 =11 147 SYSTEM SIZE(KWAC) 8.960 Q240 MODULE MODULES 28 JJINMK4O2 54HL4-B MICRO-INV,QTY 28 I I I I I I I I I I I I MICRO ENPHASE IQSMC-72-M-US I I I I I I I I I I I INVERTER UTILITY ONG ISLAND POWER AUTHORITY SEE ENLARGED VIEW uPAI FULLY STAGGERED STACKED/STAGGERED ' Rev Description Date A INITIAL DESIGN 5/11/2024 ROOF PROJECT# 9471 DATE DRAWN 5/11/2024 DRAWN BY ER ATTACHMENT DETAILS SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING ELECTRICAL EQUIPMENT LIST MAN MODULE R JINKO SOLAR MAX.CONTINUOUS OUTPUT 1.33A @ 240V ��OF NE4,� 37.24 X 1.25 = 46.55AMPS 50A FUSES-OK S.NO. ITEMS DESCRIPTION QTY MODULE MODEL JKM425N-54HL4-13 �P pE MAN/ O'p JINKO SOLAR co MODULE(W) 425 1 PV MODULE 28 JKM425N-54HL4-B PSEGLI ACCOUNT NUMBER 9670589902 at41 r METER NUMBER 98610001 Dw 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 28 MODULE PTC(W) 398.1 W 099128 = MODULE Isc(A) 13.58 O� ENPHASE COMBINER BOX MODULE Voc(V) 38.95 N CTRIGP� 3 COMBINER X-IQ-AM1-240-4/4C 1 MODULE Imp(A) 13.13 AROFESSiONP� 60A FUSED RATED 4 AC DISCONNECT D322NRB SQUARE D 1 MODULE Vmp(V) 32.37 STAMPED 05/13/2024 KNIFEBLADE LOCKABLE NEMA 311 UL LISTED (E)UTILITY METER TO UTILITY GRID THESE DRAWINGS ARE SUBJECT TO 3 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR (N) ENPHASE (E)200A RATED WRITTEN APPROVAL FROM CURRENT COMBINER BOX MAIN SERVICE PANEL RENEWABLES ENGINEERING INC. 1 1PH,120/240V 60HZ 2 CELL (E)200ABREA EIR Current WIRE LESS MODEM COMMS (TOP FED) 04 , Renewable.:1 BRANCH OF 10 N IO GATEWAY Engineering PV MODULE CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE `I` r PHONE.9551 DE CA �7-405-1733 WWW.CRENG.CO 2 BRANCH OF 9 I (N)20 (N)LINESIDE TAP VIA UL CONTRACTOR INFO PV MODULE /'� LISTED CONNECTOR I I r\ (N)FUSED t 0�� AC DISCONNECT /'\ done -- L------- -- - - C2SYS9 3 BRANCH OF 9 ELEMENT ENERGY LLC. PV MODULE N r — I 7470 SOUND AVENUE,MATTITUCK, T I J I NEW YORK,11952 PH:(631)779 7993 A B C L — services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) 1-#6 GEC,BARE COPPER (E)GROUNDING ELECTRODE Licence-HI-67461 COATED CONDUCTOR #6 BARE COPPER (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL NOTE: 2045 LONG CREEK DR, 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS SOUTHOLD,NY 11971 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE(KWDC) STC azs x ze =11 soo PTC 398.1 X 1 28 =11.147 WIRE CALCULATION SYSTEM SIZE(K WAC) g,g60 @240 STARTING ADJUSTMENT MAXIMUM JINKO SOLAR STARTING TEMPERATURE MODULES 28 JKM425N-54HL4-B CONDUCTOR CONDUCTOR CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INV.OTT 28 TAG CONDUIT ALLOWABLE TEMPERATURE CORRECTION MICRO DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO ENPHASE IQSMC-72-M-US QTY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (°C) FACTOR INVERTER 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS UTILITY ONG ISLAND POWER AUTHORITY IN RACEWAY 310.15(B)(3)(a) IN RACEWAY L'PA) SKU: Q-12-RAW-300, THHN A 6 12 N/A FREE AIR 30 90, 13.3 0.96 0.8 23.04 16.63 1 8 THWN-2 BARE COPPER-(GROUND) Rev Description Date A INITIAL DESIGN 5/11/2024 2 8 THWN-2 COPPER-(L1,L2) B 3/4" PVC 55 90° 37.24 0.96 1 52.80 46.55 1 8 THWN-2 COPPER-(GROUND) PROJECT# 1 9471 3 6 THWN-2 COPPER-(L1,L2) DATE DRAWN 5/11/2024DRAWN BY ER C 1 8 THWN-2 COPPER-(GROUND) 3/4" PVC 75 90° 37.24 0.96 1 72.00 46.55 SHEET# PV-O TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING MODULE JINKO SOLAR MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST MANUFACTURER OF NEW 37.24 X 1.25 = 46.55AMPS 50A FUSES-OK S.NO. ITEMS DESCRIPTION QTY. MODULE MODEL JKM42SN-54HL4-B �P pE MA/yj O,Q 1 PV MODULE JINKO SOLAR 28 � O w JKM425N-54HL4-B PSEGLI ACCOUNT NUMBER 9670589902 MODULE(W) 425 r_ D METER NUMBER 98610001 w MODULE PTC(W) 398.1 n 099128 2 MICROINVERTER ENPHASE IQ8MC 72 M US 28 t� LLJ MODULE Isc(A) 13.58 3 COMBINER ENPHASE COMBINER BOX 1 MODULE Voc(V) 38.95 N�OA CTRIGP\ ,� X-IQ-AM1-240-4/4C MODULE Imp(A) 13.13 ROFESSIOr1P�' 60AFUSED RATED 4 AC DISCONNECT D322NRB SQUARE D 1 MODULE Vmp(V) 32.37 KNIFEBLADE LOCKABLE STAMPED 05/13/2024 NEMA 3R UL LISTED (E)UTILITY METER TO UTILITY GRID THESE DRAWINGS ARE SUBJECT TO 3 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR (N) ENPHASE (E)200A RATED WRITTEN APPROVAL FROM CURRENT COMBINER BOX MAIN SERVICE PANEL RENEWABLES ENGINEERING INC 1 1PH,120/240V 60HZ 2 CELL (E)200A8/2P MAI N Current WIRE LESS MODEM COMMS (TOP FED) 1 BRANCH OF 10 EF­11� 40 IQ GATEWAY Engineering PV MODULE N CURRENT RENEWABLES (N)15A • • 1760 ENGINEERING GO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)405-1733 • • WWW.CRENG.CO 2 BRANCH OF 9 (N)20 A��. • (N)LINESIDE TAP VIA UL CONTRACTOR INFO PV MODULE •�i N LISTED CONNECTOR (N)20 Ai-% 4 (N)FUSED •�• (14)20A�'D AC DISCONNECT a o -no • • CZSYS 3 BRANCH OF 9 �b PV MODULE N ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 A B C services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) (E)GROUNDING ELECTRODE Licence-HI-67461 CONDUCTOR #6 BARE COPPER (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL NOTE: 2045 LONG CREEK DR, 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS SOUTHOLD,NY 11971 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE(K WDC) sTc 425 x 28 = lsoo PTC 398.1 1 X 1 28 =11.147 WIRE CALCULATION SYSTEM 512E(KWAC) g,960 @240 STARTING ADJUSTMENT MAXIMUM 11NK0 SOLAR CORRECTION STARTING TEMPERATURE MODULES 28 JKMN-54HL4-B CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INV OTY 28 CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO MICRO ENPHASE IQSMC-72-M-US QTY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (-C) FACTOR INVERTER 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS unuTv ONG ISLAND POWER AUTHORITY IN RACEWAY 310.15(B)(3)(a) IN RACEWAY `IPA) 6 12 SKU: Q-12-RAW-300, THHN A N/A FREE AIR 30 90, 13.3 0.96 0.8 23.04 16.63 1 8 THWN-2 BARE COPPER-(GROUND) Rev Date A INITTIALIAL DESIGN 5/11/2024 2 8 THWN-2 COPPER-(L1,L2) B 3/4" PVC 55 90, 37.24 0.96 1 52.80 46.55 1 g THWN-2 COPPER-(GROUND) PROJECT# 9471 3 6 THWN-2 COPPER-(L1,L2) DATE DRAWN 5/11/2024DRAWN ev E R C 3/4" PVC 75 90, 37.24 0.96 1 72.00 46.55 1 8 THWN-2 COPPER-(GROUND) SHEET# PV-41 TITLE ELECTRICAL SLD EXISTING SERVICE PANEL PHOTOS OF NEWY �P ODE MgNi,Q9 * Uj , CG r D W m W 099128 = CTRICP� AROFESSIONP� STAMPED 05/13/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)d05-1733 WWW.CRENG.CO CONTRACTORINFO ,a ® 061 EPSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) KIM &MAHLON RUSSELL 2045 LONG CREEK DR, SOUTHOLD,NY 11971 PV SUMMARY SYSTEM SIZE (KVVDC) STC 425 X 28 = L900 PTC 398.1 X 26 =11 147 SYSTEM SIZE - 8.960 C8J240 (K WAC) MODULES 28 ANKO SOLAR 1 KM42SN-54HL4-B MICRO-INV.QTY 28 MICRO ENPHASE IQ8MC-72-M-US INVERTER UTILITY ONG ISLAND POWER AUTHORITY ,PA) Rev Description Date A INITIAL DESIGN 5/11/2024 PROJECT# 9471 DATE DRAWN 5/11/2024 DRAWN BY ER SHEET# PV-4 2 TITLE ELECTRICAL PHOTOS MATERIAL LIST NE(.yy �P DE MA 0 ELECTRICAL EQUIPMENTS * Ate° �G, QTY. PART TYPE PART NUMBER DESCRIPTION D LU � w R` 099128 U- 28 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B � 6 CTRICPV 28 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US 'ORo SSIoNP� 1 FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED 1 COMBINER X2-1Q-AM 1-240-4 X2-1Q-AM 1-240-4 STAMPED 05/13/2024 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS BJECTTO COPYRIGHT PROTECTIONCTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. �,L� Current Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW CRENG CO CONTRACTORINFO BREAKER FUSES TY. aline Q PART TYPE PART NUMBER DESCRIPTION 1 FUSES 50A FUSES GENERAL 50A FUSES CZSYSs 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ELEMENT ENERGY LLC. 7470 SOUND AVENUE.MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) RACKING KIM & MAHLON RUSSELL 2045 LONG CREEK DR, QTY. PART TYPE PART NUMBER DESCRIPTION SOUTHOLD,NY 11971 24 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK PV SUMMARY SYSTEM SIZE STC 425 X 28 = 1900. 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 (KWDC) PTC 398.1 X 28 = 1147 74 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK SYSTEM SIZE 8960 @240 (K WAC) 36 CLAMPS & GROUNDING UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK nM45N-54 MODULES 28 JNKO S SOLAR L4-B MICRO-INV QTV 26 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE MICRO INVERTER ENPHASE IQSMC-72-M-US 60 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP,BLACK UTILITY lip ISLAND POWER AUTHORITY UPA1 Rev Description Date A INITIAL DESIGN 5/11/2024 PROJECT# 9471 DATE DRAWN 5/11/2024 DRAWN BY E R SHEET# PV-5 0 TITLE BOM CAUTION (<1_ OFIN MULTIPLE SOURCE OF POWER �P pO�MAN�� 0,� D W m w B A osslza 2 Z� CTRIGP� PHOTOVOLTAIC n AROFESSiONP� • '' ' ' • 1 V 1 STAMPED 05/13/2024 THESE DRAWINGS ARE SUBJECT TO 690.12 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. PV ARRAY Current TURN RAPID PV SYSTEM AC DISCONNECTt Renewabl SHUTDOWN SWITCH TO • - Engineering THE "OFF" POSITION TO � `C A NORMAL OPERATING VOLTAGE 240 •THE OA E SUITE ENGINEERING INC. 1760 CHICAG AVE SUITE SHUT DOWN PV SYSTEM 690.14,690.15,690.54 K MAIN SERVICE PANEL J-13,RIVERSIDE CA 92507 AND REDUCE SHOCK SHONE (95N< 1733 WWW.CRENG.CO "WARNIN HAZARD IN THE ARRAY P M • CONTRACTOR INFO URCES690.56(C)(1)(B) C UTILITY METER SECOND SOURCEPHOTO- V• A a 13 M RATED A , A OUTPUT P CURRENT R 4 AMP COMBINER A • - OPERATING •� VOLTAGE � AC DISCONNECT E2SYS8 u ELEMENT ENERGY LLC. 690.54 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 OPTIONAL SOLAR LOAD CENTER PH:(631)779 7993 services@e2sys.com ARRAY PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL Licence-ME-52689 PANEL IS AC DISCONNECT PER NEC690.17 (MAicence-LECTR HI-67461 (SUFFOLK HOME IMPROVEMENT) KIM& MAHLON RUSSELL J/B 2045 LONG CREEK DR, SOUTHOLD,NY 11971 PV SUMMARY INVERTER OUTPUT CONNECTION K YWDCM SIZE _ STC 425 X 28 =11.900 • • RELOCATE PTC 398.1 X 28 =11.147 NEC 690.31(G)(3)&(4),CRC R324.7 SYSTEM SIZE 8960 @zao OVERCURRENT DEVICE MODULES JINKO SOLAR AMODULES 28 JKM425N-54HL4$ MICRO-INV.OTY 28 (UNLESS BUSBAR IS FULLY RATED) L — ENPHASEIOBMc-n-M-us 705.12(D)(2) PHOTOVOLTAICP• • NOTES: UTTMER [LONG ISLAND POWER AUTHORITY PA) EVERY 10'ON CONDUIT AND ENCLOSURES 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A INITIAL DESIGN 5/11/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. PROJECT# 9471 C. AERIAL FONT. DATE DRAWN 5/11/2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN 6Y ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET4 PV-60 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. S� www-jinkosolar.com Jin1<0 Engineering Drawings •- Buiidiny Your Trust p,Sola, riger N eo N-type _ curem vaxoc•s Powe.v°°°� r•�,w•�cl,�•o.pa.w.�,c•or ..-_-_._- -...._ C-1415W1 1ccYm Pm 1 j m 54HL4-B >� -' -.�.. ii� u �'.�� "_---�--_"- ,�- � m 1W THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 4/� ���� — l 20 m _ REPRODUCTION IN ANY FORM IS L l a° -�4 EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT --- _ RENEWABLES ENGINEERING INC. ALL-BLACK MODULE - p ---- - �/'� Current N-Type Positive power tolerance of 0-+37o Engineering IEC61215(2016),IEC61730(20I6) -j�Rron+: CURRENT ENGINEERING CABLES 1509001:2015:Quality Management System ----- 1760 CHICAG wem. - O AVE SUITE ISO 14001:2015:Environment Management System PHONE: RIVERSIDE-1 92507 3 , •I ran:r'n,P CeC Type N type Morwtrystaliine PHONE:(9 NG.0 5-1733 I WW W.CRENG.CO Rw PMCM t]mm 15045001:2018 .---, -p CONTRACTOR INFO Occupational health and safety management systems A-A Dimensions 1722.1134*30mm 167.79-44.65-1.18 inch) - • •• • • • • • front 3.Zmm.An,LchionCoating, Key Features Hiah hons.n sion Low Jro Tempered ® n Glass v<Gaiie''=not S".lcX I W _..,:-TAW- Junc IP68 .:...., C 2 SYSA SMBB Technology HOT Hot 2.0 Technology ® Better tight trapping and current collection to improve _ the N-type module with Hot 2.0 technology has better ELEMENT ENERGY LLC. module power output and reliability. 2.0 reliability and lower UD/LETID. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 ;SPECIFICATIONSPH:(631)779 7993 services@e2sys.com Module Type JKM425N-54HL4- Licence-ME-52689 (MASTER ELECTRICIAN) PID Resistance ++++ Enhanced Mechanical Load Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) �� Excellent Anti-PID 9 u•Rr• Certified to withstand:wind load(2400 Pascal)and snow Maximum•Poe (rmax) 42nwp performance guarantee via a s2uwF optimized mass-production process and materials load(5400 Pascal), control. KIM & MAHLON RUSSELL Maximum Power Current(imp) 13.13A 10.60 2045 LONG CREEK DR, SOUTHOLD,NY 11971 Short-circuit Current(tsc) 13.58A 10.96A PV SUMMARY ``® Durability Against Extreme Environmental e � SYSTEM SIZE Conditions CVA ` v =tea"='Y operate Tempera�rC) -40°C-+85,C (KWDC) STc azs X 26 = 1.900 High salt mist and ammonia resistance. PTC 398.1 X 28 = 1.147 Maximum series fuse rating 25A SYSTEM SIZE g.960 (H240 (KWAC) MODULES 28 IKM4INKO SOLAR I Temperature coefficients of Prnax -0,29%/°C KM425N-54HL4-B MICRO-INV.OTY 26 LINEAR PERFORMANCE WARRANTY MICRO ENPHASE IQBMC-72-M-US INVERTER Temperature Coefficients of Isc 0.045%/1C UTILITY ONG ISLAND POWER AUTHORITY LIPA) m 100% 9- 25 Year Product Warranty Rev Description Date �STC: c Irradiance i OOOW/m2 Cell Temperature 25•C AM=1.5 A INITIAL DESIGN 5/1 112 0 2 4 30 Year Linear Power Warranty NOCT: A=Irradiance 800W/m2 ® Ambient Temperature 20°C <0 AM=1.5 Wind Speed l m/s 87.4% _ a7� PROJECT# 9471 IIIIIIIIIIN 0_40/o Annual Degradation Over 30 years DATE DRAWN 511 112 02 4 3D yeO C2023 Jinko Solar Co.,Ltd.All rights reserved. Specifications included in this datosheet are subject to change without notice. JKM405-425N-54HL4-B-F3C2-EN DRAWN BY E.R Datasheet valid in Europe only. SHEET# PV-7.0 TITLE MODULE SPEC u ENPHASE. IQ8MC Microinverter INPUT DATA IDC� UNITS IQ8MC_72 M us Commonly used module pairings' w 260-460 wModule compatibility To meet compatibility.PV modules must be within the following max.input DC voltage and max.module I_ I Module compatibility can be checked at https://enphase.com/instatters/microinverters/caIGulator. MPPT voltage range v 25-45 Operating range v 18-58 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Min./Max,start voltage v 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Max.input DC voltage v 60 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.continuous operating DC current A 14 Max.input DC short-circuit currant A 25 Current t� Max.module I A 20 _ � der: Nables - `'- Overvoltage class DC port 11 Engineering DC port backfeed current mA 0 PV array configuration Ungrounded array.no additional DC side protection required;AC side protection requires max 20 A per branch circuit CURRENT RENEWABLES ENGINEERING INC. OUTPUTs• s VAC IQ8MC • 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 Peak output power VA 330 315 PHONE:(951)-405-1733 "- --" WWW.CRENG.CO Max.continuous output power VA 320 310 CONTRACTORINFO e e Nominal grid voltage(L-L) v 240,split-phase(L-LL180' 208.single-phase(L-0,120' IQ8MC Microinverter ------- -- - -Easy to install MinJMax.grid voltage' v 2t1-284 183-229 Our newest 108 Series Microinverters are the irdustry's first microgrid-iorming'.software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 defined microimrerters with split-phase power conversion capability to convert DC power to and-play connectors Nominal frequency Viz 60 99 21 r*1 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary • Power line communication(PLC) Exterrdedhequerxyriange Hz 47-68 C SYS application-specific,integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes-This chip is built in advanced 55-nm technology with high-speed AC short circuit fault current over three digital is and has superfast response times to changing loads and rid events,alleviating Faster installation with simple two wire A� 2.70 i9 � Aar g g g � cabling OyOIes ELEMENT ENERGY LLC. constraints on battery sizing for home energy systems. Max.units per 20A(L-L)branch circuit' 12 10 7470 SOUND AVENUE,MATTITUCK High productivity and ineffability Total harmonic distortion NEW YORK,11952 x5 PH:(631)779 7993 Produces power even when the grid is services@e2sys.com down* Overvoltage class AC port m Licence-M E-52689 (MASTER ELECTRICIAN) • More than one million cumulative hours AC port backfeed current me 18 Licence-HI-67461 of testing Power factor setting 1.0 (SUFFOLK HOME IMPROVEMENT) Part of the En Class II double-insulated enclosure phase Energy System, IQB Series Microinverters redefine Grid-tied power factor(adjustable) 0.85leading...0.85 lagging KIM& MAH LON RUSSELL 108 Series Microinverters integrate with reiiability standards with more than one Optimized for the latest high-powered the 10 Battery,10 Gateway,and the million cumulative hours of power-on PV modules Peak efficiency 97.4 97.2 2 Enphase App monitoring and analysis testing.enabling an ind CECweightedefflciency szo s6.5 $OU LONG CREEK DR, industry-leading _- ---- —- - software. limited warranty of up to25years. � THOLD,NY 11971 Microgrid-forming N httime power 9 po consumption mW 33 25 PV SUMMARY Complies with the latest advanced grid MECHANICAL Support sATA UNITS SYSTEM SIZE STC -425 X 28 = 1.900 Ambient temperature range -40"C to 65`C(-40`F to 149'F) (KVVDC) Remote automatic updates for the - --- PTc 3981 1X1 28 = 1 147 latest grid requirements Relative Nmid ty range 4%to 100%(condensing) SYSTEM SIZE _ Configurable to support a wide range DC connector type 3tAubliMC4 (KWAC) 8.960 �zao JINKO SOLAR Of grid profiles Dimensions(H x W x D}•Weight 212 mm(8.3')-175 mm(8.9•)-30.2 mm 0.21:1.1 kg(7-43 Ibs) MODULES 28 JKM425N-54HL4-8 Connect PV modules quickly and easily IQB Series Microinverters are UL Listed MICRO-INV.CITY 26 to the 108 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural correction-no fans MICRO integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations;Pollution degree Yes;PD3 INVERTER : ENPHASE IQBMC-72-M-US installed according to the manufacturer's UTILITY ONG ISLAND POWER AUTHORITY instructions. Enclosure Class ll double-insulated,corrosion-resistant polymeric enclosure LIPA) NOTE: 108 Microinverters cannot be mixed together with Emiron.category;UV exposure rating NEMA Type 6:outdoor previous generations of Enphase micr m—lers (107 Series.106 series.etc.)in the same system. Rev Description Date 'Mesta UL 1741 only when imtaUed with IQ System Controller 2 and 3 IQ Gateway is required to change the default grid CA Rule 21(UL 1741-SA),UL 62109-1.IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 A INITIAL DESIGN 5/11/2024 profile at the intact installation to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and Authority Having Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's Instructions. C 2023 Enphase Energy.Alf rights reserved.E nphase,the a and CC bgm.la and certain osier marks tistad alis (1)No enforced DC/AC ratb. h,>�:i/enphase.com/trademark-r salts-Ruidsl,nes are trademarks d Enphese Energy,Inc.in the LIS and other cowries. (2)Nominal voltage range can be extended beyond nominal If required by the utility. PROJECT# 9471 Data subject to change. IQBMC-MC4-DSH-00040-7A4N-US-2023-10-18 (3)Limits may vary.Rafe,to local requirements to define the number of microinverters per branch in your area. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 DATE DRAWN 5/11/2024 DRAWN BY E.R SHEET# PV-7.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER 10 Combiner 4 IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12 20 2 0 5%) X-10-AM7-240-4 and consumption monitoring(+-2.5%)Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to X2-IQ-AM7-240-4(IEEE 1547:2018) deflect heat IQ Combiner 4C IQ Combiner 4C with IQ Gateway primed circuit board for integrated revenue grade PV production metering(ANSI C1220.0 5%) THESE DRAWINGS ARE SUBJECT TO Q Combiner 4/4 C X-I0-AMl-240-4C and consumption monitoring It 2 5%)Includes Mobile Connect cellular modem(CELLMODEM-Ml-06-SP-05),a plug-and-play COPYRIGHT PROTECTION BY US LAW The iQ Combiner 4/4C with IQ Gateway and X2-10-AM7-240-4CIEEE 15472018 industrial-grade cell modem for systems up to 60 mrcroinverters(Available in the US,Canada,Mexico,Puerto Rico and the ( ) REPRODUCTION IN ANY FORM IS US Virgin Islands where there Is adequate cellular service in the installation area.)Includes a silver solar shield to match the EXPRESSLY FORBIDDEN WITHOUT PRIOR integrated LTE-M1 cell modem(included IQ Battery and IQ System Controller and to deflect heat WRITTEN APPROVAL FROM CURRENT only with IQ Combiner 4C)consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order Separately) RENEWABLES ENGINEERING INC Supported mrcroinverters I06,IQ7,and IQ8 (Do not mix IQ6/7 Micromverters with 108) interconnection equipment into a single Current Communications Kit enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-Mt-06 IncludesCOMMS-KIT-01 andCELLMODEM-M1-06-SP-05with5-year Sprint data plan ?enQ1Nd�lE'S CELLMODEM-Mt-06-SP-05 -4G based LTE-Mt cellular modem with 5-year Sprint data planG I,J1ICELLMODEM-Mt-06-AT-05 4GbasedLTE-Ml cellular modem with 5-year AT&T data planstorage installations by providing a consistent, Engineering Circud Breakers Supports Eaton BRZ10,BRZ15,BR220,BR230,BRZ40.BR250.and BR260 arcwt breakers NPwASE pre-wired solution for residential applications. BRK-10A-2-24ov Circuit breaker,2 pole.10A.Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole.15A,Eaton BR215 CURRENT RENEWABLE$ ILI I• It offers up to four 2-pole input circuits and BRK 20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 ENGINEERING INC. BRK-15A-2P-24OV-B Circuit breaker,2 pole,15A,Eaton BR2158 with hold down kit support 1760 CHICAGO AVE SUITE Eaton BR series bUSbar assembly. BRK-20A-2P-24OV-B Circuit breaker,2 pole,20A,Eaton BR2208 with hold down kit support J-13,RIVERSIDE CA 92507 y PHONE(951)-405-1733 XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4:4C WWW.CRENG.CO XA-PLUG-120-3 Accessory receptacle for Power line Carrier in IQ Combiner 4/4C(required for EPLC-01) CONTRACTOR I NFO ---------------- - - --------- - ---- X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monnoring CT A pair of 200A split core current transformers Smart ELECTRICAL PE CLAMP) ® M ELECTRICAL SPECIFICATIONS Includes IQ Gateway for communication and control RaUng — - continuous duty ���€ Includes Mobile Connect cellular modem Yr System voltage 120/240VAC.60 Hz (CELLMODEM-M1-06 SP 05),included only with Eaton BR series busbar rating 125A IQ Combiner 4C Includes solar shield to match Enphase IQ Battery Max continuous current rating 65A ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, aesthetics and deflect heat Max continuous current rating(input from PV/storage) 64A NEW PORK,11952 Supports Wi-Fl,Ethernet,or cellular connectivity Max fuse/circuit rating(output) 90A PH:(631)779 7993 Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) services@e2sys.com Licence-ME-52689 Provides production metering and consumption Max total branch circuit breaker rating(input) 80A of distributed generation'95A with IQ Gateway breaker included (MASTER ELECTRICIAN) monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Licence-HI-67461 Production metering CT 200A solid core pre installed and wired to IQ Gateway (SUFFOLK HOME IMPROVEMENT) Simple MECHANICAL DATA KIM & MAHLON RUSSELL X-IQ-AM1.240-4C Mounts on single stud with centered brackets Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mourning brackets. 2045 LONG CREEK DR, X2-IQ-AM1-240-4C(IEEE 15472018) Supports bottom,back and side conduit entry Weight 7 5 kg(16 5lbs) SOUTHOLD,NY 11971 i Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -40-C to+46-C(-40-F to 115°F) PV SUMMARY plug-in breakers(not included) Coohng Natural convection plus heat shield 1(KWAC) 8,960 ( 80A total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction STC 425 X 28 =11,900 Wire sizes 20A to 50A breaker inputs:14 to 4 AWG copper conductors PTC 398.1 X 28 =11.147 Reliable 60A breaker branch input 4 to 1/0 AWG copper conductors SYSTESYSTEg.960 �240Main lug combined output.10 to 2/0 AWG copper conductors g240JINKO 50LAR Neutral and ground 14 to 1/0 copper conductors 28 JKM425N-54HL4-B Durable NRTL-certifled NEMA type 3R enclosure Always follow local code requirements for conductor sizing. 28 Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet)Two years labor reimbursement program coverage ENPHASE IDB POWER -us INTERN ET CONNECTION OPTIONS [LONG ISLAND PowERAUTHORIrY included for both the IQ Combiner SKU's e -- ---------------- --_-___-__-____ ____-. .___-________.- -.._.._._.-___..__—...--__-.._---_-.___.____. ___ UTILITY LIPA) Integrated Wi-Fi IEEE 802 11b/g/n l X-IQ-AMt-240-4 -_ - UL Cellular CELL MODEM-M1-06-SP-OS,CFLLMODEM-M1-06-AT-OS(4G based LTE-Mlcellular modem) Note that an Mobile Connect X2-Iisted Q-AMl-240-4 and X2-IQ-AM1-240-4C comply with cellular modem Is required for all Enphase Energy System installations X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 15472018 '°UL 1741-SB,3 Ed. ( ) Ethernet Optional,IEEE 802.3,CatSE(or Cat6)UTP Ethernet cable(not included) Rev Description Date COMPLIANCE A INITIAL DESIGN 5/11/2024 _ Compliance,IQ Combiner CA Rule 21(UL 1741-SA) IEEE 15472018-UL 1741-SB,3'Ed (X2-1Q-AM1-240-4 and X2-IQ-AM7-240-4C) CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003 PROJECT# 9471 Production metering ANSI C12.20 accuracy class 0.5(PV production) ENPHAS E. Consumption metering accuracy class 2 5 DATE DRAWN 5/11/2024 To learn more about Enphase offerings,visit enphase•s�m `� Compliance,10 Gateway UL 60601 1!CANCSA 22.2 No 61010-1 DRAWN BY ER IQ-C-4-4C-DS-0103-EN-US-12-29-2022 0 2022 Enphase Energy.All rights reserved Enphase,the Enphase logo,IO Combiner 4/4C,and other names are trademarks of SHEET# PV-7.2 Enphase Energy,Inc Data sublect to change IQ-C-4-4C-DS-01 03-EN-US-1 2-29-2022 TITLE COMBINER SPEC /1r IRONRIDGE XR Rail° Family XR Rail`" Family The XR RaiP Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Sear !s Not Always 13l.:fr►n+or design loads, while minimizing material costs. Depending on your location,there is an XR Raif" to match. �^ Over their lifetime°solar panels experience countless THESE DRAWINGS ARE SUBJECT TO extreme weather events Not just the worst storms in ears COPYRIGHT PROTECTION BY US LAW. 1 y � � v R l but the worst storms in 40 years. High winds capable of REPRODUCTION IN AN FORM S + EXPRESSLY FORBIDDEN WITHOUT PRIOR ripping panels from a roof. and snowfalls weighing \, WRITTEN APPROVAL FROM CURRENT enough to buckle a panel frame. _ RENEWABLES ENGINEERING INC. XR Rails" are the structural backbone ��, Current preventing these results.They resist uplift. XR10 XR100 XR1000 �enewables protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and Commercial XR10DO is a heavyweight among Engineering and efficiently transfer loads into the rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle building structure.Their superior no snow.It achieves spans up to 6 feet, wind and snow conditions.while also extreme climates and spans up to 12 CURRENT RENEWABLES spanning capability requires fewer while remaining light and economical. maximizing spans up to 10 feet feet for commercial applications. ENGINEERING INC. _ 1760 CHICAGO AVE SUITE roof attachments, reducing the 6'spanning capability 10'spanning capability 12'spanning Capability J-13,RIVERSIDE CA92507 of roof penetrations Moderate load Capability Heavy load Capability Extreme load Capability PHONE:(951)-405-1733 number and the of root a Clear&black anodized finish Clear&black anodized finish Clear anodized finish WWW.CRENG.CO • Internal splices available Internal splices available Internal splices available CONTRACTOR INFO installation time. Rail Selection I The table below was prepared in compliance with applicable engineering codes and standards.' Values are A ^���^`S � based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B. Roof L Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. ��- ELEMENT ENERGY LLC. .• :. •. 7470 SOUNDNEW OE TT1TUCK, RK,11 52 7m, • ®� secence-ole2sy2689 Licence-ME-52689 Force-Stabilizing Curve 90 ,. (MASTER ELECTRICIAN) Sloped roofs generate both vertical and lateral Licence-HI-67461 forces on mounting rails which can cause tllerrl to 120 (SUFFOLK HOME IMPROVEMENT) ed bend and twist.The curved shape of XR Railsg None 1 � rs specialty designed to increase strength in both 140 XR10 XRW 7(R1000 K I M& M A H LO N R U SS E LL directions while resisting the twisting.This unique 160 2045 LONG CREEK DR, feature ensures greater security during extreme weather and a longer system lifetime. 90 SOUTH OLD,NY 11971 PV SUMMARY 120 SYSTEM SIZE 20 KWDC STC 425 X 28 141 140 - PTC 3981 X 28 = 1.147 SYSTEM SIZE -. .. - 160 SYSTEM8.960 Q240 11NKO SOLAR 90 MODULES 28 1KM425N-54HL4-B 30 MICRO-INV,QTY 28 ------ -- - 160 MICRO ENPHASE IQBMC-72-M-US INVERTER Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials [LONG UTILITY PA)ISLAND POWER AUTHORITY XR Rails'are IronRidge`otters All XR Rails are made of 6000-series �. � 40 compatible with a range of tiff leg aluminum alloy,then protected with an I 160 A FlashFootr"and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing 80 160 Rev Description Date attachments. applications. a more attractive appearance. 120 160 A INITIAL DESIGN 5/11/2024 -Table is meant to be a amplified spar.chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. PROJECT# 9471 DATE DRAWN 5/11@024 r :rr r DRAWN BY ER SHEET# PV-73 TITLE RAIL SPEC Adaptive, Rafter-Friendly Installation /lr IRONRIDGE QuickMount° The Respect Your Roof Deserves • THESE DRAWINGS ARE SUBJECT TO When integrating with a home,solar attachments COPYRIGHT PROTECTION BY US LAW REPRODUCTION IN ANY FORM IS must be dependable for the lifetime of the rooftop M6 g ' EXPRESSLY FORBIDDEN WITHOUT PRIOR Due to recent innovations, many asphalt shingles _- Y"'C... -- _ - - WRITTEN APPROVAL FROM CURRENT / RENEWABLES ENGINEERING INC. have bonded courses Amount that protects without the need to pry shingles can really speed things up. I Current Halo UltraGrip'(HUG`)is here to respect the roof. �,ewables Its Halo is a cast-aluminum barrier that encases the Engineering UltraGrip.our industrial-grade.foam-and-mastic seal.This allows HUG to accelerate the installation Hit the rafter?Good to •• CURRENT RENEWABLES ENGINEERING INC. process and provide the utmost in waterproofing • • • • • • • • • ' __'_' •deck 1760 CHICAGO AVE SUITE than 3 screws MISS the rafter, protection Give your roof a HUG. J-13 RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG CO CONTRACTORINFO Multi-Tiered Waterproofing Trusted Strength & Less Hassle HUG'utilizes a nluhrtiered stack of Components to provide revolutionary waterproor#1g protection The Halo cast- Structural capacities of HUG' were reviewed inis 0 01 Affriiinumsurrounds raised-penmeter pbase-afofoundation man load directions. with racking rail running surrounds the UttraGnp base-a foam- y g g U1 ed mastic seat coatlon that cross-slope or up-slope in relation to roof pitch. 9 mbm Cz S YS prevents water intrusion by adhering sea%V with the shingle surface For further details,see the HUG certification ELEMENT ENERGY LLC. 3rip'"Is part letters for attaching to rafters and decking. 7470 SOUND AVENUE,MATTITUCK, of the --kMount• NEW YORK,11952 - .,e PH:(631)779 7993 "•—^' IronRidge designed the HUG, in combination services@e2sys.com _------— - with the RD Structural Screw to streamline Licence-ME-52689 UltraGrip`Seal Technology installs, which means the following: (MASTER ELECTRICIAN) Licence-HI-67461 HUG UhraGnp utilizes a state-of-the- - (SUFFOLKHOME IMPROVEMENT) art seal design that uses a unique. foam-and-mastic combination.The prying 9 foam-backed adhesive provides an NO In shingles - No roof nail interference KIM & MAHLON RUSSELL entireynewflashingsystemI-at 25-Year Warranty No pilot holes necessary 2045 LONG CREEK DR, conforms and adheres to every nook -' ,CdG Ssa'd^teed'r; and cranny ofcomposrtronshingles, _ ._ ^�pat�:rtgdefeCs. No sealant(in most cases) SOUTHOLD,NY 11971 �' � filling gaps and shingle step-downs No butyl shims needed (up to 1/B-in height). r --- - - -- --- - - PV SUMMARY SYSTEM SIZE STC 425 X 28 =11 900 K WDC) Attachm ent PTC 398.1 X 28 =11 147 UL ' • • , . Design • RatingsSystem (SYSTEM SIZE 8,960 _240 K WAC) •� MODULES 28 1INKO SOLAR 1 KM425N-54H L4-B MICRO-INV.OTV 28 MICRO ENPHASE IQ8MC-72-M-US "- INVERTER Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to UTILITY ONG ISLAND POWER AUTHORITY LI PA) Mount HUG to the roof rafters,the roof HUG has been and certified for the UL 441 Section i UL 2703 mechanical •" fv. deck.or both with our custom-engineered RD(rafter-or-deck)Structural Screw The RD tested and rated to compliance with 27"Rain Test'and and bonding Triple Rated&Certified Structural Screw anchors HUG to the roof support 1004(Ibs)of the International TAS 100(A)-95 requirements. See to Respect the Roof- • " with an EPDM sealing washer,completing Rev Description Date u UL 2703.441(27) h the stack of waterproofing barriers See uplift and 368(Ibs) Building Code 8� Wind Driven Rain Flush Mount Manual A INITIAL DESIGN 5/11f2024 Intertek TAS 100(A)-95 backside for more installation information. Of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. PROJECT# 9471 0 2023 lronRidge,Inc.All rights reser,,ed.Visit www.ir-patents.com for patent inforrnation.Version 1 03 DATE DRAWN 511112024 DRAWN BY ER SHEET# PV-7.4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd Hayward.CA 94545 28357 Industrial Blvd. /lr I R O N R I D G E 1-800-227-9523 1-ao0-Hayward. -9 94545 IronRidge.corn I RON RI DGE 23 IrlxtRidge.coe.com Attn:Corey Geiger.COO, IronRidge Inc. Date:September 7"',2021 The parameters and adjustments allowed in the span tables are defined as the following: THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5 1. REPRODUTION IN ANY FOM EXPRESSLY FORBIDDEN WITHOUT PRIOR 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B for Risk Category II and applicable state&local WRITTEN APPROVAL FROM CURRENT ( 9 rY ) PP RENEWABLES ENGINEERING INC. This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System The county/city amendments to the IBC. No special wind topographic features are included and both topographic contents of the letter shall be read in its entirety before applying to any project design The Flush Mount System is a coefficient(Kr)and wind ground elevation factor(Ke)are taken as 1.0. Current proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails applicable Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig.7.2-1 and :3f@S• � and secured to the rails with IronRidge mounting clamps The XR Rails are side mounted to a selected roof applicable state&local county/city amendments to the IBC the local jurisdiction specified snow load is in the Engineering format of a flat roof snow,it shall first be converted to a ground snow following the local building code/ attachment with 3/8'stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables No special snow conditions are considered CURRENT RENEWABLES that is fastened to the underlying roof structure Assembly details of a typical Flush Mount installation and Its core including unbalanced,drifting,sliding,retention,or ponding snow No rain-on-snow surcharge load is ENGINEERING INC. o coin nents are shown in Exhibit EX-0015. considered.The span tables do not apply to buildings which are intentionally kept below freezing,kept just 1760 CHICAGO AVE SUITE P J-13.RIVERSIDE CA 92507 above freezing.Or unheated. PHONE.(951)-405-1733 WWW.CRENG.CO The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: CONTRACTOR INFO listed below,for the load conditions and configurations tabulated in the attached span tables. (a)For ground snow no greater than 42psf Ss s 2 Og for Site Class A.B,C,&D ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf-S6<_1.0g for Site Class A.B,C,&D 10 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:SS<_1 5g for Site Class A,B C. &D 2020 Building Code of New York State(BCNYS-2020. Published in November 2019) E��`/�O 2015 Aluminum Design Manual(ADM-2015) 5 Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in TT LJ Report SEAOC(Structural Engineer Association of Califomia)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCp) Roof zones comprising each group along with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall NEW YORK,11952 the respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load PH:(631)779 7993 &configuration condition from the span tables,or 36". Services@e2sys.com ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8`to 45°. The tabulated spans are applicable when the Licence-ME-52689 following conditions are met: 7 Allowable span length in the charts may be multiplied by a factor of 1 08 it the rails are continuous over (MASTER ELECTRICIAN) Licence-HI-67461 a minimum of three spans (SUFFOLK HOME IMPROVEMENT) 1 Span is the distance between two adjacent roof attachment points(measured at the center of the attachment fastener) B. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: KIM & MAHLON RUSSELL a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2/3 of end spans. 2045 LONG CREEK DR, 2 Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system) Spans are Calculated b) BOSS Splice can be installed at any location within a span. SOUTHOLD,NY 11971 based on 2 rail systems.and conservatively deemed acceptable for 3 rail systems 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If Pv SUMMARY o p such conditions are encountered contact support@ironridge com SYSTEM SIZE src azs x zB =n Soo 3 The underlying roof slope measured between the roof surface and horizontal plane is 8 to 45 (KWDC ETC 3981 1 X 1 28 =11 147 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured SYSTEM slzE fi.96o '—dzao (K WACI from grade,does not exceed 30 feet MODULES 28 )INKO SOLAR 1KM425N-54HL4-B MICRO-INV OTY 28 5. A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the MICRO ENPHASE ID8Mc-72-M-US INVERTER height of the array.the distance from the module top surface to the roof surface(defined as h2),shall not ONG ISLAND POWER AUTHORITY UTILITY LI PA) exceed 10 6 Module length and area shall not exceed the maximum values listed on the respective span tables. Rev Description Date A INITIAL DESIGN 511112024 7- All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge s Flush Mount Installation Manual and other applicable standards for the general roof construction practice. PROJECT# 9471 DATE DRAWN 5/112024 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-1 ©2021 IronRidge,Inc. NY Flush Mount System Certification Letter-2 DRAWN BY ER SHEET# PV-7.5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward,CA 94545 Hayward,CA 94545 IRONRIDGE lronRi ge.cor23 IRONRIDGE IronRi ge.o5m3 IronRidge.com 10. Systems using CAMO module clamps shall be installed with the following guidance: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67.5 CAMO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater Such consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting THESE DRAWINGS ARE SUBJECT TO members It is the responsibility of the installer or stem designer to verify the structural capacity and adequacy of the COPYRIGHT PROTECTION R IS LAW scenarios are shown by asterisks in the applicable span tables. P Y Y 9 fY P Y q Y REPRODUCTION IN ANY FORM IS b) CAMO will function within a module's design load ratings.Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration tE,,xPRESSAPPROVAL RBIDDEN WITHOUT CURRENT PRIOR RITTEN CAMO meets the dimensional requirements shown in the figure below and that the module selected is RENEWABLES ENGINEERING INC suitable for the environmental conditions of a particular project �of NEW 2 0 1 0 9 0 7 Sincerely, P� NG xr, �O Current — - _ iiewables µoo,JeGass,ceksr. (,� - 15:45: 16 - Engineering CURRENT RENEWABLES _O�/] O 0 ENGINEERING INC. �ESSiO�t� 1760 cHlcnco AVE SUITE Frame Compafibity: _ J-13.RIVERSIDE CA 92507 X=11-2.2 mm PHONE.(951)-405-1733 Y=15-40 mm WVeM'CRENG CO Gang Xuan, PE CONTRACTOR INFO —Y -- Senior Structural Engineer Figurer CAMO Module Flame Dimensional Requirement_ ® rM Span values for Exposed and Edge module conditions, as defined below, are included in the attached span EcSYSL) tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; ELEMENT ENERGY LLC. (2)The span value determined by site wind speed and ground snow load.Additionally, irrespective of the lesser 7470 SOUND AVENUE,MATTITUCK, span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clam usage NEW PORK.11952 P P 9 P g PH:(631)779 7993 limitation detailed in note 9 of page 2 shall apply to the respective condition. services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) 1. Exposed Module conditions: L -Hi- (SUFFOLK 67461 HOME IMPROVEMENT) A module is defined as Exposed(per Section 29 4 4 of ASCE 7-16)if the distance from any of its free KI M & MAH LON RUSSELL edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave, ridge rake.or 2045 LONG CREEK DR, hip)is greater than 0 5h(h is ASCE defined building height)AND if the distance from its free edge to any SOUTHOLD,NY 11971 other adjacent array or panel is greater than 4 feet. Pv SUMMARY SYSTEM SIZE STC 425 X 28 =11.900 The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed (KWDC) Modules. PTC 398 1 [XI 28 1=11.147 SYSTEM SIZE(K WAC) g g60 9240 2. Edge Module Conditions: MODULES 2B JKM4 SOLARN-54 JINKO -54HL4-B [IN ICRO-INV.QTY 28 ICRO ENPHASE IQ8MC-72-M-US A module is defined as an Edge Module when its distance from any side of the module to its facing VERTERperimeter roof edge(such as eave.ridge,rake,or hip)is less than 2 times the height of the array(2h2) TILITv LI(LIPA ISLAND POWER AUTHORITY where h2 is measured from the roof surface to the top surface of the module. The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules Rev Description Date Additionally,if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered A INITIAL DESIGN 5111/2024 for this span adjustment. PROJECT# 9471 2021 IronRidge.Inc NY Flush Mount System Certification Letter-3 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-4 DATE DRAWN 5n v2o24 DRAWN BY E.R SHEET# PV-7.6 TITLE CERTIFICATION ROOF MOUNT SOLAR PERMIT PACKAGE NEw yo D KIM & MAHLON RUSSELL *���oO�RT'TA. `4 * A UG 2 s 11 .900 KW DC GRID TIED PHOTOVOLTAIC SYSTEM W zo ,„ 2 Building 10 De art nt 2045 LONG CREEK DR. SOUTHOLD., NY 11971 STAMPED 08M7M24 Z`rFop 106793 �C' Town of S utho Ss0 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES: Exp:9/30/2025 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY REPRODUCTION IN ANY FORM IS POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION EXPRESSLY FORBIDDEN WITHOUT PRIOR 2020 NEW YORK STATE BUILDING CODE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES WRITTEN APPROVAL FROM CURRENT C RENEwABLES ENGINEERING INC2020 NEW YORK STATE RESIDENTIAL CODE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED C 2020 NEW YORK STATE MECHANICAL CODE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE j 2017 NATIONAL ELECTRICAL CODE UNDERSIGNED Current 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 RenewableS y 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT ^ tk SUCH AS GeoCel 2300 CLEAR SEALANT Engineering T THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED CURRENT RENEWABLES 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, ENGINEERING INC. fj MECHANICAL,OR BUILDING ROOF VENTS 1760 CHICAGO AVE SUITE AHJ:TOWN OF SOUTHOLD 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS J-13.RIVERSIDE CA 92507 THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PHONE(951)-405-1733 10, EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED WwwCRENG Co CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S CONTRACTOR INFO INSTALLATION INSTRUCTIONS" 6 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA uM UTILITY METER PM PRODUCTION METER REGULATIONS • 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. SP MAIN SERVICE PANEL INV INVERTER 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. Ez SYS9 BUILDING INFORMATION COMBINER SUB SUB PANEL 15 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. AC DISCONNECT LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE ELEMENT ENERGY LLC. NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF 7470 SOUND AVENUE,MATTITUCK, 2 STORY HOUSE SINGLE FAMILY RESIDENCE NEWYORK,11952 MODULE I(2 IQ CONTROLLER 2 REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. pH:(631)779 7993 18, CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" serv:(631) 29 799 m CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U ROOF OBSTRUCTIONS Arr BATTERY ABOVE ROOF SURFACE. Licence-ME-52689 36"ACCESS PATHWAYS 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE (MASTER ELECTRICIAN) RATED FOR EXPOSURE,TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN Licence-HI-67461 AP N : 1000055000700005000 QH Q.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)1013 OR 1213 CONDUCTORS THROUGH (SUFFOLK HOME IMPROVEMENT) 18"ACCESS PATHWAYS OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT SHEET INDEX AC ESS DISCONNECT 20 MATERIALS,,R UI ES N D RE INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, KI M & MAHLON RUSSELL ROOF ACCESS POINT STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO L C LOAD CENTER THE PURPOSE INTENDED: 2045 LONG CREEK DR, PV_1.0 COVER PAGE = RAIL SOUTHOLD,NY 11971 - _ RAFTER 0 LOT NO. :- 0.84 ACRES PV-2. SITE PLAN SEPTIC TANK -- -- -.. - - • PV SUMMARY ATTACHMENT SYSTEM SIZE PV-2.1 ROOF PLAN SSS LEACH LINES WIND SPEED 128 (KWDC) STC 425 x 28 = 1.900 PV-3.0 STRUCTURAL BE MAIN BREAKER PROPANE TANK SNOW LOAD 25 PTC 3981 x 28 = 1.147 ENCLOSURE SYSTEM SIZE EXPOSURE CATEGORY C B PV-4.0 _ELECTRICAL 3LD TS AUTOMATIC TRANSFER WELL MODULES 28 �240 11NK0 SOLAR PV�.1 ELECTRICAL SLD SWITCH STRUCTURAL NOTES: MoouLEs 1KM425N-54HL4-B j POWER LINES 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF MICRO-INV CITY 28 MICRO EN PHASE IQ8MC-72-M-US PV-4.2 ELECTRICAL PHOTOS OP PERMANENT ANCHOR ---,) NO LADDER ACCESS THE ROOF FRAMING SUPPORTING THE PROPOSED PV INSTALLATION ONLY. INVERTER (STEEP GRADE 2.THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. UTILITY ONG ISLAND POWER AUTHORITY PV 5 0 BOM TO TEMPORARY ANCHOR L OR GROUND LEVEL 3. PV MODULES, RACKING,AND ATTACHMENT COMPONENTS MUST FOLLOW PA) PV-6.0 SIGNAGE & PLACARD OBSTRUCTIONS) MANUFACTURER GUIDELINES AND REQUIREMENTS. IL INSTALLER LADDER 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT PV-7.0 SPECS+ As GAS SHUT OFF Rev INITIAL Dale FOR ADDITIONAL INFORMATION. A INITIAL DESIGN 5/11r2024 S STUB-OUT Hzo WATER SHUT OFF 5. PRIOR TO COMMENCEMENT OF WORK,THE SOLAR INSTALLER SHALL Al UPDATEDDESIGN r2o24 -- - -- - - - - - --- - VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE ® SKYLIGHT D SERVICE DROP E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND PROJECT# 9471 FOLLOWING: DATE DRAWN enrzoza -- - - - RESTRICTED ACCESS JUNCTION BOX ROOF 1:2x10 RAFTERS @ 16"OC SPACING WITH MAX UNSUPPORTED SPAN DRAWN BY ER EQUAL OR LESS THAN 17 FT. CONDUIT ROOF 2:2x10 RAFTERS @ 16"OC SPACING WITH MAX UNSUPPORTED SPAN SHEET PV-10 EQUAL OR LESS THAN 26 FT. TITLE T ROOF 3:2x10 RAFTERS @ 16"OC SPACING WITH MAX UNSUPPORTED SPAN COVER PAGE - - - EQUAL OR LESS THAN FT.23 R324.6.1 PATHWAYS: WIND SPEED 128 LEGEND NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SEPARATE ROOF PLANES, SNOW LOAD 25 FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. EXPOSURE CATEGORY C __ n AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR `� �7 UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. PROPERTY LINE �1� -�-_ FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING • COMBINER THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE ` OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS \`• El AC DISCONNECT WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT. ! MODULE R324.6.2 SETBACK AT RIDGE: / \• .............. ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN 36"ACCESS PATHWAYS AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A • THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. If 97 -3 • tIN, COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 18"ACCESS PATHWAYS REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A I • �� EXPRESSLY FORBIDDEN WITHOUT PRIOR \ . MSP C ROOF ACCESS POINT WRITTEN APPROVAL FROM CURRENT 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A � � RENEWABLES ENGINEERING INC. HORIZONTAL RIDGE. I R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS \`� c Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED / Renewables THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING.A 361NCH-WIDE PATHWAY SHALL BE ••\ / Engineering PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. 46 Ifi� NOTES: /, 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED I • CURRENT R G INC. LES ROOF ACCESS POINT E60CHIC GOAVES. ON ACTUAL SITE CONDITION AND ' \ 178A RIVERSIDE AVCA E SUITE MEASUREMENTS. J-13.RIVERSIDE-1733 7 I ; � PHONE:(951F40S7733 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS ROOF OBSTRUCTION WWW CRENG CO INCORPORATED INTO THE 2017 NEC AND UL 1 ,_11 n � CONTRACTOR INFO STANDARD 1741. 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. ROOF LINE ; V mom i� 38,_1 „ �/ EZSYSA N v �— ELEMENT ENERGY LLC. FENCE 7470 SOUND AVENUE,MATTITUCK, DRIVEWAY NEW YORK.11952 ][ PH:(631)779 7993 • .r w services@e2sys.com Licence-ME-52689 XL IROOF ACCESS POINT LU (MASTER ELECTRICIAN) Licence-HI-67461 I • . ` / ` V (SUFFOLK HOME IMPROVEMENT) ' �...':•.. (D KIM & MAHLON RUSSELL if l ��o NEw y z Q 2045 LONG CREEK DR, ����OFRj A. Z4 0 SOUTHOLD,NY 11971 % * * PV SUMMARY I ,•' • / SYSTEM SIZE STC 425 X 28 = 1.900 / ,• k PTC 398.1 X 28 = 1.147 SYSTEM SIZE 8.960 0240 (KW! 112' 11 " ••, v(O^ 106793 �`t�� MODULES 28 JINKO SOLAR _ /" V JINKO SOLAR / '��FESSION MICRO-INV.OTY 28 MICRO ENPHASE IQ8MC-72-M-US Exp:9/30/2025 INVERTER ONG ISLAND POWER AUTHORITY I / STAMPED 0=7/2024 UTILITY LI PA) i PROPERTY LINE Rev Desaiptlon Date -�� A INITIAL DESIGN 5/112024 - A UPDATED DESIGN aR2024 �- PROJECT# 9471 -��^' (� DATE DRAWN 8/72024 •h�V DRAWN BY ERSITE �1/3 A�1 -�O' ��✓ 1 SHEET TITLE SCALE: 2" = SITE PLAN ARRAY AREA LEGEND ARRAY ROOF ROOF TOTAL ROOF AZIMUTH #OF AREA AREA AREA AREA uM UTILITY METER MODULES (Sq.Ft.) (Sq.Ft.) COVERED BY COVERED BY ARRAY(%) ARRAY(%) SP MAIN SERVICE PANEL #1 232° 13 273.26 4036 6.77 COMBINER #2 142° 9 189.18 4036 4.69 14.58 c❑ #3 142° 1 6 126.12 1 4036 1 3.12 �c AC DISCONNECT DMODULE ROOF OBSTRUCTIONS 36"ACCESS PATHWAYS THESE DRAWINGS ARE SUBJECT TO 18"ACCESS PATHWAYS COPYRIGHT PROTECTION BY US LAW. / REPRODUCTION IN ANY FORM IS RAIL EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RAFTER RENEWABLES ENGINEERING INC Ks C 0 ATTACHMENT Current .- .,wabies / Engineering CURRENT RENEWABLES J ENGINEERING INC. SUITE PHO E(951 DE AVE 92507 PHONE(951)4057733 / CRENG CO CON —� CONTRACTOR INFO UM ® EcSYSA / 0 ELEMENT ENERGY LLC. I I I I I I I I I 3 I 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 c w PH:(631)779 7993 i E c um secence-ole2sy2689 Licence-ME-52689 U (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) - _ ROOF#2 O KIM & MAHLON RUSSELL J 2045 LONG CREEK DR, SOUTHOLD,NY 11971 .( PV SUMMARY -- — \�OT NEwY SKWDCM SIZE STC 425 X 28 =11.900 -- + GAP �1 r!,4 O�L RTC 398.1 X 28 =11.147 SYSTEM SIZE (KWAC) 8.960 @240 ---- ( MODULES 28 JINKO SOLAR r" 1KM425N-54HL4$ ROOF#3 MICRO-INV.OTY 28 N 28 INKO SOLAR 1KM425N-54HL4-B C '� MICRO ( ) 1 \ INVERTER ENPHASE IOBMC-72-M-US ONG ISLAND POWER AUTHORITY V 106793 UTILITY LIPA) 41 FESS � Exp:9/30/2025 Rev Desaiption Date STAMPED 08/07/2024 A INITIAL DESIGN 5/11/2024 A.1 UPDATED DESIGN 8/7/2024 41 �" PROJECT# 9471 DATE DRAWN 8/7/2024 DRAWN BY ER 2 ROOF PLANL ROOF#1 SHEET# PV-21 TITLE SCALE: 3/32" = 1'-0" ROOF PLAN TABLE 1 TABLE 2 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG Osz ATTACHMENT IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ROOF 1 32° COMP SHINGLE RAFTER 2X10 16" 64" 24"s3 RAIL IRONRIDGE XR-100 RAIL ROOF 2 37° COMP SHINGLE RAFTER 2X10 16" 64" 2411 ROOF 3 26° COMP SHINGLE RAFTER 2X10 16" 64" 24" P.��OF NEW y0n Lj� OKRA A• (4 'rL THESE DRAWINGS ARE SUBJECT TO O<e, I/* COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Clf WRITTEN APPROVAL FROM CURRENT r RENEWABLES ENGINEERING INC. CFO 106793 ��� Curren; — — — A��FESSIO�P� n Engineerirg Exp:9/30/2025 CURRENT R G INC. LES STAMPED OSM7/2024 ENGINEERING NC. 1760 CHICAGO AVE SUITE MODULE J-13.RIVERSIDE CA 92507 PHONE:(951)4057733 WW W.CRENG.CO S3 CONTRACTORINFO TABLE : PENETRATION S2 GUIDE FOR INSTALL ROOF TWO OR MORE ROWS OF PANELS EPSYSA ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTRUCK, NEW YORK,11952 2.5"MIN.EMBED. PH:(631)779 7993 I services@e2sys.com I I I I I I I I I I I I I I I I I I I Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (2)-#14 X 3" SELF DRILLING (SUFFOLK HOME IMPROVEMENT) STRUCTURAL SCREWS TO S1 EXISTING STRUCTURE KIM &MAHLON RUSSELL 4. 2045 LONG CREEK DR, SOUTHOLD,NY 11971 ENLARGED VIEW STACKED STAGGERED FULLY STAGGERED PVSUMMARY SYSTEM SIZE STC 425 X 28 =11,900 (K WDC) ONE ROW OF PANELS I PTC 398.1 1 x 1 2e = 1147 SYSTEM SIZE 8.960 6240 (KWAC) MODULE MODULES 28 1 JINKO KM4 SOLARN-54-54HL4-B MICRO-INV.QTY 28 I I I I I I I I I I I I MICRO ENPHASE IQSMC-72-M-US INVERTER UTILITY LONG ISLAND POWER AUTHORITY LI PA) FSEE ENLARGED VIEW FULLY STAGGERED STACKED/STAGGERED Rev Desvipti°n Date A INITIAL DESIGN 5/11/2024 At UPDATED DESIGN &712024 ROOF PROJECT# 9471 DATE DRAWN 8/7/2024 DRAWN BY ER ATTACHMENT DETAILS SHEET# PV-30 TITLE STRUCTURAL BACKFEED FUSE SIZING MODULE JINKO SOLAR OF NE(1, ELECTRICAL EQUIPMENT LIST MANUFACTURER MAX.CONTINUOUS OUTPUT 1.33A @ 240V 'C� �'p S. NO. ITEMS DESCRIPTION QTY. �P OE MAN/q� ,� 37.24 X 1.25 = 46.55AMPS 50A FUSES-OK MODULE MODEL JKM425N-54HL4-B ZO �9C JINKO SOLAR * U G 1 PV MODULE 28 S JKM425N-54HL4-B MODULE(W) 425 PSEGLI ACCOUNT NUMBER 9670589902 r � D � METER NUMBER 98610001 n W 2 _W 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 28 MODULE PTC(W) 398.1 09912B2 MODULE Isc(A) 13.58 ��Q < P� �O C RI 7G 3 COMBINER ENPHASE COMBINER BOX 1 MODULE Voc(V) 38.95 A�p�SS10NP� X-IQ-AM1-240-4/4C MODULE Imp(A) 13.13 60A FUSED RATED STAMPED 08/07/2024 4 AC DISCONNECT D322NRB SQUARE D 1 MODULE Vmp(V) 32.37 KNIFEBLADE LOCKABLE NEMA 3R UL LISTED (E)UTILITY METER TO UTILITY GRID THESE DRAWINGS ARE SUBJECT TO 3 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR (N) ENPHASE (E)200A RATED WRITTEN APPROVAL FROM CURRENT COMBINER BOX MAIN SERVICE PANEL © RENEWABLES ENGINEERING INC. 1 1PH,120/240V 60HZ (E)200A/2P MAIN Current 2 CELL WIRE LESS BREAKER MODEM COMMS (TOP FED) Renewakles 1 BRANCH OF 10 IQ GATEWAY Engineering PV MODULE N CURRENT RENEWABLES f ENGINEERING INC. ——————— N)15A• • 1760 CHICAGO AVE SUITE •— J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 ( •� WWW.CRENG.CO 2 BRANCH OF 9 I (N)20A/ i • (N)LINESIDE TAP VIA UL CONTRACTOR INFO PV MODULE N (N)20A I ;� LISTED CONNECTOR r------� /� I 4 ( I I I (N)FUSED •� (N)20 I I AC DISCONNECT I ; C2SYS9 3 BRANCH OF 9 I IELEMENT ENERGY LLC. PV MODULE N r------------- I 7470SOUND AVENUE.MATTITUCK, f I I NEW YORK,11952 J I PH:(631)779 7993 A B C L services@e2sys.com -- Licence-ME-52689 (MASTER ELECTRICIAN) 1-#6 GEC,BARE COPPER (E)GROUNDING ELECTRODE _ Licence-HI-67461 COATED CONDUCTOR #6 BARE COPPER (SUFFOLK HOME IMPROVEMENT) KIM& MAHLON RUSSELL NOTE: 2045 LONG CREEK DR, 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS SOUTHOLD,NY 11971 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE STC azs x zB =11900 (K WDC) PTC 398.1 X 28 =11.147 WIRE CALCULATION SYSTEM SIZE PTC •3980 (K WAC) 24 STARTING ADJUSTMENT MAXIMUM JINKO SOLAR CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE STARTING TEMPERATURE MODULES 28 JKM425N-54HL4$ CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INV QTY 28 CORRECTION MORE THAN CONDUCTOR APPLIED TO MICRO ENPHASE IQSMC-72-M-US TAG DESCRIPTION APPLIED TO CITY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (°C) FACTOR INVERTER 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS UTILITY ONG ISLAND POWER AUTHORITY IN RACEWAY 310.15(B)(3)(a) IN RACEWAY "PA) 6 12 SKU: Q-12-RAW-300,THHN q N/A FREE AIR 30 90° 13.3 0.96 0.8 23.04 16.63 Rev Description Date 1 8 THWN-2 BARE COPPER-(GROUND) A INITIAL DESIGN 5/11/2024 2 8 THWN-2 COPPER-(L1,L2) Al UPDATED DESIGN BU/2024 g 3/4"PVC 55 90° 37.24 0.96 1 52.80 46.55 1 g H N-2 PIPER-(GROUND) PROJECT# 9471 DATE DRAWN B/7/2024 3 6 THWN-2 COPPER-(L1,L2) DRAWN BY ER C 3/4" PVC 75 90° 37.24 0.96 1 72.00 46.55 1 8 THWN-2 COPPER-(GROUND) SHEET# Pv40 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING MODULE JINKO SOLAR OF NEw ELECTRICAL EQUIPMENT LIST MANUFACTURER MAX.CONTINUOUS OUTPUT 1.33A @ 240V l'O S.NO. ITEMS DESCRIPTION QTY. �P OpEM`�N/ .� 37.24 X 1.25 = 46.55AMPS 50A FUSES-OK MODULE MODEL JKM425N-54HL4-B JINKO SOLAR * 4U ? 1 PV MODULE JKM425N-54HL4-B 28 425 PSEGLI ACCOUNT NUMBER 9670589902 r g D DC MODULE(W) W METER NUMBER 98610001 n W N 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 28 MODULE PTC(W) 398.1 Z 099128 MODULE Isc(A) 13.58 crR1c 3 COMBINER ENPHASE COMBINER BOX 1 MODULE Voc IV) 38.95 'ORp�SS1ONP�' X-IQ-AM1-240-4/4C MODULE Imp(A) 13.13 60A FUSED RATED STAMPED 08/07/2024 4 AC DISCONNECT D322NRB SQUARE D 1 MODULE Vmp IV) 32.37 KNIFEBLADE LOCKABLE NEMA 3R UL LISTED (E)UTILITY METER TO UTILITY GRID THESE DRAWINGS ARE SUBJECT TO COPYRIGHT 3 REPRODUCTION NE ANY OFORM IN BY US S EXPRESSLY FORBIDDEN WITHOUT PRIOR (N) ENPHASE (E)200A RATED WRITTEN APPROVAL FROM CURRENT COMBINER BOX MAIN SERVICE PANEL RENEWABLES ENGINEERING INC. 1 1PH,1201240V 60HZ (E)200A/2P MAIN Current 2 CELL WIRELESS BREAKER MODEM COMMS (TOP FED) n 1 BRANCH OF 10 N IQ GATEWAY Engineering PV MODULE � CURRENT RENEWABLES E (N)15A ENGINEERING INC. • • 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE:(951)405-1733 •�i W W W.CRENG.CO 2 BRANCH OF 9 �(N)2011�_ • (N)LINESIDE TAP VIA UL CONTRACTOR INFO PV MODULE •�i LISTED CONNECTOR N (N)20 Am 4 /�• ® (N)FUSED •�• (N)20�� AC DISCONNECT — :�• CZSYSS 3 BRANCH OF 9 PV MODULE <NV ELEME7470 SOUND NAVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 A B C services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) (E)GROUNDING ELECTRODE Licence-HI-67461 CONDUCTOR #6 BARE COPPER (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL NOTE: 2045 LONG CREEK DR, 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS SOUTHOLD,NY 11971 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE(KWDC) src 425 x za = lsoo PTC 398.1 X 28 =11.147 WIRE CALCULATION SYSTEM SIZE 8960 (9240 (KWAC) STARTING ADJUSTMENT MAXIMUM MODULES 28 JINKO SOLAR STARTING TEMPERATURE KM425N-54HL4-B CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INV QTY 28 CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION MORE THAN 3 CONDUCTOR APPLIED TO ENPHASE IQBMC-72-M US TAG DESCRIPTION APPLIED TO MICRO CITY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (°C) FACTOR CONDUCTORS AMPACITY CONDUCTORS INVERTER ONG 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) UTILITY IN RACEWAY 310.15(B)(3)(a) IN RACEWAY ONAG)ISLAND POWER AUTHORITY 6 12 SKU:Q-12-RAW-300, THHN q N/A FREE AIR 30 90° 13.3 0.96 0.8 23.04 16.63 Rev Description Date 1 8 THWN-2 BARE COPPER-(GROUND) A INITIAL DESIGN 5111/2024 2 8 THWN-2 COPPER-(L1,L2) A.1 UPDATED DESIGN 8n/2024 B 3/4" PVC 55 90° 37.24 0.96 1 52.80 46.55 1 8 THWN-2 COPPER-(GROUND) PROJECT# 9471 DATE DRAWN 8/7/2024 3 6 THWN-2 COPPER-(L1,L2) DRAWNBY ER C 3/4" PVC 75 90° 37.24 0.96 1 72.00 46.55 1 8 THWN-2 COPPER-(GROUND) SHEET J/ I - "I TITLE ELECTRICAL SLD EXISTING SERVICE PANEL PHOTOS OF NEW �P pQE MAN/� D W m 'L oss,2e a Z CTRIGP� V O SS% STAMPED 08A17/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWWCRENG.CO CONTRACTORINFO mum EZSYS9 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL 2045 LONG CREEK DR, SOUTHOLD,NY 11971 PV SUMMARY SYSTEM SIZE - STC 425 X 28 = 1.900 (KWDC) PTC 398.1 X 28 = 1.147 SYSTEM SIZE g_g60 @240 (K WAC) MODULES 28 JINKO SOLAR MICRO-INV.QTY 28 JKM425N-54HL4-B MICRO : ENPHASE IQ8MC-72-M-US INVERTER ONG ISLAND POWER AUTHORITY UTILITY - LIPA) Rev Description Date A INITIAL DESIGN 5/11/2024 At UPDATED DESIGN 8/7/2024 PROJECT# 9471 DATE DRAWN 8f7l2024 DRAWN BY ER SHEET# PV-4.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST (�OF NEINy ,`P E MA/yyq O ELECTRICAL EQUIPMENTS D QTY. PART TYPE PART NUMBER DESCRIPTION m - 09912E 28 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B 2�``a �� TRAP` 28 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US ssl°NPR 1 FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED STAMPED Oa/07/2024 1 COMBINER X2-1Q-AM1-240-4 X2-1Q-AM1-240-4 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC Current - Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)405-1733 WWW CRENG.CO CONTRACTORINFO BREAKER / FUSES a m QTY. PART TYPE PART NUMBER DESCRIPTION C25Y5° 1 FUSES 50A FUSES GENERAL 50A FUSES 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 servicesCo)e 2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL RACKING 2045 LONG CREEK DR, QTY. PART TYPE PART NUMBER DESCRIPTION SOUTHOLD,NY 11971 24 RAILS & SPLICES XR-100-168B XR100, RAIL 16811 BLACK PVSUMMARY SYSTEM SIZE STC 425 X 28 =11.900 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 KwoC) FTC 3981 X 28 = 1.147 74 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK SYSTEM SIZE K WAC) 8960 @240 JINKO SOLAR STOPPER SLEEVE, 35MM, BLACK MODULES 28 JKM425N-54HL4-B 36 CLAMPS & GROUNDING UFO-STP-35MM-B1 MICRO-INV OTY 26 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE N'�ER ER ENPHASEQSMC-72-M-Us LONG ISLAND POWER AUTHORITY 66 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP,BLACK DTILn I LIPAI Rev Description Date A INITIAL DESIGN 5111/2024 At UPDATED DESIGN 8/7/2024 PROJECT# 9471 DATE DRAWN 8/7/2024 DRAWN BY E.R SHEET# PV-5 0 TITLE BOM CAUTION ��°F NEw y P OE MANi �.p MULTIPLE SOURCE OF POWER >k 4 Z r g D m _W oss,2e = CTRIGPX'P `C) V o SS%oN PHOTOVOLTAIC SYST — STAMPED OM7/2024 • • HP. THESE DRAWINGS ARE SUBJECT TO 690.12 I W COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. PV ARRAY Current TURN RAPID L — • Renewabtes Engineering SHUTDOWN SWITCH TO RATED • - AMPS CURRENT RENEWABLES THE "OFF" POSITION TO ACI AC NORMALOPERATING VOLTAGE •LTS ENGINEERING INC. SHUT DOWN PV SYSTEM 1-13,Rl760 ERSI AVE SUITE 690.14,690.15,690.54 MAIN SERVICE PANEL J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 AND REDUCE SHOCK WWW CRENG CO HAZARD IN THE ARRAYFr;c CONTRACTOR INFO P M , POWERUAL SOURCES UTILITY METER 690.56(C)(1)(B) SEC• D SOURCE IS PHOTO-V• A � I OUTPUTRATED AC COMBINER I I - a 13 SCONNECTE I —••� CZSYSU AC NORMAL OPERATING VOLTAGE - 240 VOLTS AC DI 7470 SOUND AVENUE,MATTITUCK, ELEMENT ENERGY LLC. 690 54 LONG CREEK DR NEW YORK,11952 OPTIONAL SOLAR LOAD CENTER PH:(631) 3 services@e2sys.c2sys.com ARRAY PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL Licence-ME-52689 PANEL IS AC DISCONNECT PER NEC690.17 (MASTER ELECTRICIAN) (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL J/B 2045 LONG CREEK DR, SOUTHOLD,NY 11971 PV SUMMARY INVERTER OUTPUT • • SYSTEM SIZE STC 425 X 28 =11.900 KWDC) PTC 398.1 X 1 28 141 • • RELOCATE NEC 690.31(G)(3)&(4),CRC R324.7 SYSTEM SIZE(KWAC) 8.960 @zao OVERCURRENT DEVICE 11NK0 SOLAR ♦ MODULES 28 JKM425N-54HL4-B MICRO-INV.OTY 28 (UNLESS BUSBAR IS FULLY RATED) • • • • • • • MICRO ENPHASE IO8MC-72-M-US 705.12(D)(2) NOTES: INVERTER UTILITY [LONG ISLAND POWER AUTHORITY LI PA) EVERY 10'ON CONDUIT AND ENCLOSURES 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Dale A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A INITIAL DESIGN 5/11/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. Al UPDATED DESIGN Ba12024 B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. PROJECT# 9471 C. AERIAL FONT. DATE DRAWN af7/2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PVbo HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. $ola'z www.jinkosolar.com Jin1<0 Engineering Drawings - - 5uildiac Your Trust -a-W. Tiger Neo N-type -- -- �.� �.� ra*vm�w.�,d..,�•w m 54H L4-B �, �qq `� tt '_------��--- - 6 ,m � THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 42 5 Watt ( ` • REPRODUCTION IN ANY FORM IS m ` � m I EXPRESSLY FORBIDDEN WITHOUT PRIOR J -m WRITTEN APPROVAL FROM CURRENT 2 RENEWABLES ENGINEERING INC. ALL-BLACK MODULE a s e ss m a m m .o• m ; i Current N-Type .�. >a' °°� a ;D I tewabies Positive power tolerance of 0-+397. Engineering CURRENT RENEWABLES IEC61215(2016),IEC61730(2016) ENGINEERING INC. CHICAGIS09001:2015:Quality Management SystemMechanical ' ' _ristics 1780 RIVERSI AVE SUITE i 1 '�`�� � J-13,RIVERSIDE CA 92507 ISO14001:2015:Environment Management System T I 4 I •! 1 I� Cell Type N type Monocrystafne PHONE:(951)-405-1733 I J '•��}�I WNM,.CRENG.CO 15045001:2018 CONTRACTOR INFO Occupational health and safety management systems •+ Dimensions 1722.1134.30mm,(67.79.44.65.1.18 rCh) Key Features •• V. 3n,,T .ofi LowW n Coatire High Trarsm®on.Low Yon Tempted Glass +c paz• dom Junction Box 0168 Rated E Z SYS9 SM89 Technology Hot 2.0 Technology ® Better light trapping and current collection to improve NOT the N-type module with Hot 2.0 technology has better module power output and reliability 2.0 refabifity and lower LID/LETID. ELEMENT ENERGY LAC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 SPECIFICATIONSPH:(631)779 7993 services@e2sys.com r.>txf.��?voe AM425ti 5AH_4-8 Licence-ME-52689 (MASTER ELECTRICIAN) ® PID Resistance +++E Enhanced Mechanical Load STC NOCT Licence-HI-67461 a — -- -- --- — -- - - (SUFFOLK HOME IMPROVEMENT) Excellent Anti-PID performance guarantee via Ea a Certified to withstand:wind load(2400 Pascal)and snow Mmdmum Power(Pmax) 42:;w� 320wc optimized mass-production process and materials :` ter„ load(5400 Pasca)- contra. — _-_-- _____ 32s7v 3019v KIM& MAHLON RUSSELL Mammum Power Cument(Imp) 38.95v 37.00v 2045 LONG CREEK DR, — -- --- SOUTHOLD,NY 11971 Shcrtcscuif Current(IX:) `®4 ^ Module Efficiency STC(%) 21 76% PV SUMMARY Durability Against Extreme Environmental ® Q �1Z'1� SYSTEM SIZE C E �ij s� �� m ne•a�g a ae aNre(Y; (KWDC) STC 425 X 28 =11 SIX)Conditions �� Maximum system vt�IYpe ;000v DC"EC; RTC 398.1 X 26 =11_147 High salt mist and ammonia resistance. _--_ ^naxir",..:rr series fuse•ar -. SYSTEM SIZE (KWAC) 8.960 @240 Power tolerance _ -. aim° MODULES 28 11NKO SOLAR Teperature coefficients of Prr� „�. 1KM425N-54HL4-B m MICRO-INV.OTY 28 LINEAR PERFORMANCE WARRANTY -0'25%�C _ MICRO ENPHASE I08MC-72-M-US Temperature coefficients of Isc �J4cm r.0 INVERTER ONG ISLAND POWER AUTHORITY 45i2^C A UTILITY LI PA) m 100% 99% 25 Year Product Warranty �$TC:1 irradiance I OOOW/m' ® Cell Temperature 25•C AM=1.5 Rev Description Date A INITIAL DESIGN 5/1172024 30 Year Linear Power Warranty NOCT; _[Irradiance 80OW/m' Z Ambient Temperature 20°C QP AM=1.5 Wind Speed Im/s At UPDATED DESIGN Br712024 0 v 87,4^, PROJECT# 9471 u years 0.4076 Annual Degradation Over 30 years DATE DRAWN 8n72024 ;a 30C2023 Jinko Solar Co.,Ltd.All rights reserved. Specifications included in this datosheet are subject to change without notice. JKM4OS-425N-S4HL4-B-F3C2-EN DRAWN BY ER Datasheet valid in Europe only. SHEET# PV-7 0 TITLE MODULE SPEC ENPHASE. IQ8MC Microinverter INPUT DATA(DC) UNITS 10PIAC-72-M-US Commonly used module pairings w 260-460 .Module compatibility To meet compatibility,PV modules must be within the following max.input DC voltage and max.module I_ Module compatibility can be checked at https://err iase.com/installers/microlnverters/calculator. MPPT voltage range v 25-45 Operating range v 18-58 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Min./Max.start voltage v 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Max.input DC voltage v 60 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.continuousoperating DC current A 14 Max.input DC short-circuit urrent A 25 Current (� Max.module I. A 20 -i ew a bl e s Overvoltage class DC port 11 Engineering DC port backteed current mA 0 Pv array configuration Ungrounded array:no additional DC side protection required:AC side protection requires max 20 A per branch circuit CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 Peak output power VA 330 315 PHONE:(951)-4057733 W W W.CRENG.CO Max.continuous output power VA 320 310 CONTRACTOR INFO Nominal grid voltage(L-L) v 240.spilt-phase(Li.),t80r 208,single-pha 8(L-LX 20' 1 Q 8 M C M i c ro i n ve rte r Easy to install Min./Max.grid voltage' v 2T1-264 — --------—-- -- -- 183-229— — - — Our newest IQ8 Series Microinverters are the industry's first microgrid-forming'.software- Lightweight and compact with plug- Max.continuous output current A 1.33 t,W defined microlnverters with split-phase power conversion capability to convert DC power to and-play connectors Nominal frequency H= 80 MEN AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary • Power line communication(PLC) 'nerded fray H= 47-68 CZSYS 10 application-specific integrated circuit(ASIC).which enables the microinverter to operate in between components E -- - grid-tied or off-grid modes.This chip is built in advanced 55-rim technology with high-speed AC short circuit fault current over three • Faster installation with simple two-wire A,� 2-70 digital logic and has superfast response times to changing loads and grid events.alleviating cabling cycles ELEMENT ENERGY LLC. constraints on battery sizing for home energy systems. Max.units per 20 A(L-L)branch circuit 3 12 10 7470 SOUND AVENUE,MATTITUCK, - NEW YORK,11952 High productivity and reliability Total harmonic distortion 5 PH:(631)779 7993 � x Produces power even when the grid is services@e2sys.com down' Overvoltage class AC port tll Licence-ME-52689 (MASTER ELECTRICIAN) More than one million cumulative hours AC port backfeed current mA 18 Licence-HI-67461 of testing Power factor setting 1.0 (SUFFOLK HOME IMPROVEMENT) Part of the En Energy S Class II double-insulated enclosure Grid-tied power factor(adjustable) 0.85 leading.-.0.85 lagging Enphase gy System, IQ8 Series Microinverters redefine K I M & MAH LO N R U SSE LL IQ8 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the 10 Battery,10 Gateway,and the million cumulative hours of power-on PV modules Peak efficiency % 97.4 97.2 2045 LONG CREEK DR, Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efttclency 97.0 96.5 SOUTHOLD, NY 11971 software. limited warranty of up to 25 years. Microgrid-forming Nighttime power consumption mw 33 25 PV SUMMARY Complies with the latest advanced grid MECHANICAL DATA UNITS SYSTEM SIZE F) KWDC) STC X 28 = 1.900 support Ambient temperature range -40`C to 65`C(-40`F to 149° ( • Remote automatic updates for the PTC 398.98.1 1 x 1 zg 1A.14747 latest grid requirements Relative humidity range 496to 10096(condensing) SYSTEM SIZE g%0 �240 connector type (KWAC) • Configurable to support awide range DC _. S1tMC4 _ _.. -------------of grid profiles Dimensions(H-W•Dk Weight 212 mm(82"•175 Trim(8.V)•302 Trim(12');1.1 kg(2.43 Ibs) MODULES 28 JINKO SOLAR Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed MICRO-INV.QTY 28 JKM425N-54HL4-B to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans F;::�4.. -- ------ NPHASE IO8MC-72-M-US integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations;Pollution degree Yea;PD3 nstalled according to file manufacturer's NG ISLAND POWER AUTHORITY instructions. Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure PA) NOTE: 108 Microfnverters cannot be mixed together with Environ.category;UV exposure rating NEMA Type 6;outdoor previous generations of Enphase microinverters COMPLIANCE (107 Series.106 Series.etc.)in the same system. Rev Description Date 'Maas UL 1741 only when installed with t0 System Controller and 3. 10 Gateway¢required to change the default grid CA Rule 21(UL 1741-SA).UL 62109-1.IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 A INITIAL DESIGN 5/11/2024 profile at the time of installation to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014.NEC 2017.NEC 2020.and NEC 2023 section 690.12 and Authority Having Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. AT UPDATED DESIGN gn/2024 C 2023 Enphaae Energy.All righs reserved.Enpfwa,the a end CC logos.10 and certain other marks listed at _____ _____ (1)No enforced DC/AC ratio. ass !nips://anphase-co— -tidemark-usage-euidNines are trademarks ot Enphass Energy,Inc.in the US and other countries. (2)Nominal voltage range ran be extended beyond nominal If required by the utility. PROJECT# 9471 Data eubiect to change KAW-MC4-DOtF00 3001-US-2023-10.18 (3)Limits may vary.Rotor to local requirements to define the number of mi—inverters per branch in you,area. IOBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 DATE DRAWN 8p/2024 DRAWN BY E.R SHEET# PV-7.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER IQ Combiner 4 IQ Combiner 4 with IQ Gateway primed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0 5%) X-I0-AMl-240-4 and consumption monitoring(±2.5%).Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to X2-IQ-AMl-240-4(IEEE 1547:2018) deflect heat --- ---- ---- ----- IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.2010 5`­: THESE DRAWINGS ARE SUBJECT TO X-10-AM1-240-4C and consumption monnonng(±2.5%).Includes Mobile Connect cellular modem(CELLMODEM-MI-06-SP-05),a plug-and-play COPYRIGHT PROTECTION BY US LAW. Q Combiner 4/4 C The IQ Combiner 4/4C with IQ Gateway and industrial-grade cell modem for systems up to 60 microinverters(Available in the US Canada.Mexico,Puerto Rico,and the X2-IQ-AM1-240-0C(IEEE 1547.2018) REPRODUCTION IN ANY FORM IS US Virgin Islands wherethere is adequate cellular service in the installation area.)Includes a silver solar shield to match the EXPRESSLY FORBIDDEN WITHOUT PRIOR integrated LTE-Ml cell modem (included IQ Battery and IQ System Controller and to deflect heat WRITTEN APPROVAL FROM CURRENT only with IQ Combiner 4C)consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) RENEWABLES ENGINEERING INC Supported microinveners 106,107,and IQ8.(Do not mix 106/7 Microinverters with I08) interconnection equipment into a single Communications Kit 0_ A Current enclosure It streamlines I Microinverters and COMMS-CELLMODEM-Ml-06 -Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan Renewables QCELLMODEM-M1-06"SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data planstorage installations by providing a consistent, CELLMODEM-Mt-06-AT-05 4GbasedLTE-Mt cellular modem with5-year AT&T data plan Engineering Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230.BR240,BR250-and BR260 circuit breakers. EN—ASE pre-wired solution for residential applications. BRK-10A-2-240V Cncud breaker,2 pole 10A Eaton BR210 BRK-t5A-2-240V Cucurt breaker,2 pole,15A.Eaton BR215 CURRENT RENEWABLES It offers up to four 2-pole input circuits and SRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 ENGINEERING INC. BRK-15A-2P-24OV-8 Circuit breaker,2 pole,15A.Eaton BR2158 with hold down kit support 1760 CHICAGO AVE SUITE Eaton BR Se(IeS bUSbaf assembly- BRK-20A-2P-240V-B Circuit breaker,2 pole,20A.Eaton BR220B with hold down kit support J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 i XA-SOLARSHIELD-ES Replacement solar shield fo,iQ Combiner 4 4C V✓NNV.CRENG.CO 1 )CA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) CONTRACTOR INFO X-10-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT A pair of 200A split core current transformers Smart (CT-200-SPLITfCT-200-CLAMP) i ELECTRICAL SPECIFICATIONS Includes IQ Gateway for communication and control - " - continuous duty — f EZSYS° Includes Mobile Connect cellular modem Svstem.voltage 120/240VAC,60 Hz (CELLMODEM-M1-06-SP-O5),included only with t Eaton BR series busbar rating 125A IQ Combiner 4C ELEMENT ENERGY LLC. includes solar shield to match Enphase IQ Battery Max continuous current avng 65A 7470 SOUND AVENUE,MATTITUCK, aesthetics and deflect heat Max continuous current rating(input from PV'storage) 64A NEW YORK,11952 Supports Wi-Ft,Ethernet,or cellular connectivity Max fusetc,rcart rating ioutpot 90A PH:(631)779 7993 • Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) services@e2sys.com Licence-ME-52689 Provides production metering and consumption Max total branch circuit breaker rating(input; 80A of distributed generation'95A with IQ Gateway breaker included (MASTER ELECTRICIAN) monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Productior metering CT 200A solid core pre installed and wired to IQ Gateway Simple MECHANICAL DATA _ — _ KIM & MAHLON RUSSELL X IQ AMl 240-4C Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16 8 cm(14.75 in x 19-5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. 2O4S LONG CREEK DR, „! Mounts on single stud with centered brackets X2-IQ-AM1-240-4C(IEEE 1547:2018) Supports bottom,back and side conduit entry weight 7 5 kg(16 5lbs) SOUTHOLD,NY 11971 t Ambient temperature range -40-C to+46-C(-40-F to 115°F) • Allows up to four 2-pole branch circuits for 240VAC PV SUMMARY plug-in breakers(not included) Coohng Natural convection plus heat shield SYSTEM SIZE 80A total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified.NEMA type 3R,polycarbonate construction (KWDC) STC 425 X 26 =11.9D0 PTC 3981 X 28 =11.147 _ We s¢es 20A to SOA breaker inputs.14 to 4 AWG copper conductors SYSTEM SIZE 11 60A breaker branch input 4 to 1/O AWG copper conductors g 960 g240 Reliable • Main lug combined output.10 to 2/0 AWG copper conductors (KWAC) Neutral and ground 14 to 1/0 copper conductors MODULES 28 JINKO SOLAR 1 KM425N-54HL4-B Durable NRTL-certified NEMA type 3R enclosure Always follow local code requirements for conductor sizing. MICRO-WV QTY 28 Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) MICRO ENPHASE IQ8MC-72-M-US I Two ears labor reimbursement program coverage INVERTER y P 9 9 INTERNET CONNECTION OPTIONS LONG ISLAND POWER AUTHORITY included for both the IQ Combiner SKU's -- -- UTILITY IPA) Integrated W i-Fi IEEE 802.t t b/g/n _ X-IQ-AM1-240-04_ UL listed Cellular CELLMODEM-M1-06-SP-OS,CELLMODEM-Mt-06-AT-05(4G based LTE-M1 cellular modem).Note that an Mobile Connect X2-IQ-AM1-240-4 and X2-I0-AMl-240-4C comply with cellular modem is required for all Enphase Energy System installations X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 15472018 UL 1741-SB,3`°Ed. ( ) Ethernet Optional,IEEE 802.3.CatSE(or Cat6)UTP Ethernet cable(not included) Rev Description Date COMPLIANCE A INITIAL DESIGN 5/11/2024 Compliance,IQ Combiner CA Rule 21(UL 1741-SA) A UPDATED DESIGN a/712024 IEEE 1547 2018-UL 1741-SB,3"Ed.(X2-I0 AM1-240-4 and X2-I0-AM7-240-4C) CAN/CSA C22.2 No.1071,Title 47 CFR,Part 15,Class B.ICES 003 PROJECT# 9471 w Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering accuracy class 2 5 DATE DRAWN 8q/2024 ENPHASE. Compliance,IQ Gateway UL 60601 CANCSA 22 2 No 61010 1 DRAWN BY E R To learn more about Enphase offerings,visit enohase.com IQ-C-4-4C-DS-0103-EN-US-12-29-2022 C 2022 Enphase Energy.All rights reserved Enphase,the Enphase logo.IQ Combiner 4/4C,and other names are trademarks of SHEET# PV-7.2 Enphase Energy,Inc Data sub)ect to change IQ-C-4-4C-DS-0103-EN-US 12 29-2022 TITLE COMBINER SPEC //r IRONRIDGE XR Rail° Family XR Rail° Family The XR Rail®Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads,while minimizing material costs. Depending on your location,there is an XR Rail®to match. Over their lifetime.solar panels experience countless THESE THESE DRAWINGS ARE SUBJECT TO extreme weather events. Not just the worst storms in years, "' COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS but the worst storms in 40 years. High winds capable of EXPRESSLY FORBIDDEN WITHOUT PRIOR FROM ripping panels from a roof, and Snowfalls weighing _ RNEWABLESVAL EON INCENGINEERING CURRENT E enough to buckle a panel frame. r�„ —���..,�'�+ Current XR Rails" are the structural backbone preventing these results.They resist uplift, \��� XR10 XR100 XR1000 �" �ewdb�eS protect against buckling and safely t XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among — Engineering and efficiently transfer loads into the rail.designed for regions with light or mounting rail.It supports a range of solar mounting rails.Its built to handle buildingstructure.Their superior _ no snow.It achieves spans up to 6 feet. wind and snow conditions,while also extreme climates and spans up to 12 CURRENT RENEWABLES su p while remaining light and economical maximizing spans up to 10 feet. feet for commercial applications- ENGINEERING INC. spanning capability requires fewer 1760 CHICAGO AVE SUITE fOOf attachments. reducing the 6'spanning Capability 10'spanning capability 12'spanning capability J-13.RIVERSIDE CA 92507 • Moderate load capability Heavy load Capability Extreme load Capability PHONE:(951)-405-1733 number of roof penetrations Clear&black anodized finish Clear&black anodized finish Clear anodized finish WWW CRENG CO and the amount of Internal splices available Internal splices available - Internal splices available CONTRACTOR INFO installation time. Rail Selection � ® n The table below was prepared in compliance with applicable engineering codes and standards.' Values are CZSYSQ based on the following criteria:ASCE 7-16. Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B. Roof u f Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. j ELEMENT ENERGY LLC. 7470 SOUND AVENUE.MATTITUCK, e • . e. NEW PORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 90 EECTRICIAN) STE Force-Stabilizing Curve (M Lic nc a LHII-67461 Sloped roofs generate both vertical and lateral 120 (SUFFOLK HOME IMPROVEMENT) forces on mounting rails which can cause them to Norte bend and twist.The Curved shape of XR RailsV 140 XR10 XR100 XR1000 KIM & MAHLON RUSSELL is specialty designed to increase strength in both / directions while resisting the twisting.This unique 160 2045 LONG CREEK DR, feature ensures greater security during extreme weather and a longer system lifetime. I SOUTHOLD,NY 11971 90 PV SUMMARY 120 SYSTEM SIZE 20 (KWOC) STC 425 X 28 = 1.900 140 PTC 398.1 1 X 1 28 = 1.147 SYSTEM SIZE` 160 (KWAC) 8960 Q240 MODULES 28 ANKO SOLAR 90 1KM425N-54HL4-B 30 MICRO-INV.CITY 28 160 MICRO ENPHASE IQBMC-72-M-US - __. --- INVERTER Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 UTILITY ON4G)ISLAND POWER AUTHORITY JUP XR Rails'are IronRidge@ offers All XR Rails are made of 6000-series 40 1 compatible with a range of tilt leg aluminum alloy,then protected with an A 60 1 FlashFoot"and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,white also providing 80 160 Rev Description Date attachments. applications. a more attractive appearance. - `-I A I INITIAL DESIGN 5/11/2024 120 160 A.1 UPDATED DESIGN 8l72024 'Table i5 meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance PROJECT# 9471 2023 AJI�' r DATE DRAWN 8/7/2024 DRAWN BY ER SHEET# PV-7.3 TITLE RAIL SPEC Adaptive, Rafter-Friendly Installation /fir IRONRIDGE QuickMount' The Respect Your Roof Deserves • � THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. When integrating with a home,solar attachments + REPRODUCTION IN ANY FORM IS must be dependable for the lifetime Of the rooftop. EXPRESSLY FORBIDDEN WITHOUT PRIOR --- -- -------_---__ y WRITTEN APPROVAL FROM CURRENT Due to recent innovations. many asphalt shingles �*) RENEWABLES ENGINEERING INC have bonded courses.A mount that protects without f the need to pry shingles can really speed things up. Current Halo UltraGrip'(HUG`)is here to respect the roof_ 1�! Its Halo is a cast-aluminum barner that encases the 3 = Engineering 1 UltraGrip.our industrial-grade,foam-and-mastic seal.This allows HUG to accelerate the installation ••• CURRENT RENEWABLES When ENGINEERING INC. process and provide the utmost in waterproofing ' • •' " ' Place another screw rafter Structural Screws are needed. 'the left' secure It If ' 1760 CHICAGO AVE SUITE protection.Give your roof a HUG.' _ • •• J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG CO CONTRACTORINFO Mufti-Tiered Waterproofing Trusted Strength & Less Hassle HUG`utilizescomponents t a milfi-provide stack of Cprthporhents to provide revolutionary waterproofing protection The Halo cast- Structural capacities of HUG were reviewed in _ aluminum.raised-perimeter foundation many load directions, with racking rail running surrounds the UltraGrip base-a foam- C SYS laced mastic seal combination that cross-slope or up-slope in relation to roof pitch. u preverhtS water intrusion by adhering with the shingle surface For further details, see the HUG certification ELEMENT ENERGY LLC. Ha'.o UltraGrip'"is part letters for attaching to rafters and decking. 7470 SOUND AVENUE,MATTITUCK, GluickMount• -' NEW 11952 PH:(631)31)77 779 7993 line. IronRidge designed the HUG, in combination services@e2sys.com —--- with the RD Structural Screw to streamline Licence-ME-52689 (MA UltraGrip Seal Technology ;�' ;� installs,which means the following: Licence-LHI 67461 HUG UttraGnp utilizes a state-of-the-, (SUFFOLK HOME IMPROVEMENT) art seal design that uses a unique, 1J foam-and-mastic combination.The No prying shingles foam-backed adhesive provides an No roof nail interference KIM & MAHLON RUSSELL entirely new flashing system that i, 25-year Warranty No pilot holes necessary 2045 LONG CREEK DR, conforms and adheres to every Product guaranteed free and cranny of composition shingles, of impairing defects. No sealant(in most cases) SOUTHOLD,NY 11971 filling gaps and shingle step-downs - - L No butyl shims needed PV SUMMARY (up to 1/8-in height). - ij SYSTEM SIZE rT (KWDC) STC 425 X 28 =11.900 Att PTC 3981 X 28 =11.147 • SYSTEM SIZE 8 960 @240 Loading DesignRatings (KWAC) •� MODULES 28 1JINKO SOLAR KM425N-54HL4-B -- - - MICRO-INV QTY 28 MICRO ENPHASE IQ8MC-72-M-US -. INVERTER Rafter&Deck Mounting Options The rafter-mounted ! Parts are designed HUG passed both Systems conform to uTlurr ONG ISLAND POWER AUTHORITY Mount HUG to the roof rafters,the roof HUG has been and certified for the UL 441 Section UL 2703 mechanical LIPA) • �• deck,or both with our custom-engineered I 27"Rain Test'and and bonding RD(rafter-or-deck)Structural Screw.The RD tested and rated to I compliance with 9 Triple Rated&Certified • {► Structural Screw anchors HUG to the roof support 1004 (Ibs)of the International TAS 100(A)-95 requirements. See Rev Description Date to Respect the Roof" • f with an EPDM sealing washer,completing uplift and 368 (Ibs) Building Code& "Wind Driven Rain Flush Mount Manual UL 270&441(27 the stack of waterproofing barriers See A INITIAL DESIGN 5/11/2D24 6Intertek TAS 100(A)-95 backside for more Installation information. Of lateral load. I ASCEJSEI-7. Test"by Intertek. for more info. A UPDATED DESIGN Sr7/2024 PROJECT# 9471 0 2023 fronRidge.Inc.All rights reserved.Visit w—ir-patents.com for patent information.Version 1.03 DATE DRAWN 8/7/2024 DRAWN BY E R SHEET# r'V-7 4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd Hayward,CA 94545 28357 Industrial Blvd. Hayward,CA RON RI DGE 1-800-227-9523 1-800 94 227 9523-1,45 IronRidge corn I RON RI DGE IronRidge.com Attn:Corey Geiger,COO,IronRidge Inc. Date:September 7"' 2021 The parameters and adjustments allowed in the span tables are defined as the following: THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1. REPRODUCTION IN ANY FORM IS Re:Structural Certification and Span Tables for the IronRidge Flush Mount System EXPRESSLY FORBIDDEN WITHOUT PRIOR 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B(for Risk Category II)and applicable state&local WRITTEN AES PPROVAL LEERING FROM RENT This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System The county/city amendments to the IBC. No special wind topographic features are included and both topographic contents of the letter shall be read in its entirety before applying to any project design The Flush Mount System is a coefficient(Kr)and wind ground elevation factor(Ke)are taken as 1.0. rooftop mounting system used to support Current proprietary p g ys pport photovoltaic(PV)modules installed in portrait or landscape 1,,� orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails 3. Snow load used in the span tables Is the ground snow and shall conform to ASCE 7-16 Fig.7.2-1 and t' �dleWak�les applicable state&local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the Engineering and secured to the rails with IronRidge mounting clamps The XR Rails are side mounted to a selected roof format of a Flat roof snow,it shall first be converted to a ground snow following the local building code/ 4 attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables No special snow conditions are considered CURRENT RENEWABLES that is fastened to the underlying roof structure Assembly details of a typical Flush Mount installation and its core including unbalanced.drifting.sliding:retention.or ponding snow No rain-on-snow surcharge load is ENGINEERING INC. components are shown in Exhibit EX-0015. considered.The span tables do not apply to buildings which are intentionally kept below freezing,kept just 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 above freezing.Or unheated. PHONE.(951)-405-1733 WWW.CRENG.CO The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being CONTRACTOR INFO listed below,for the load conditions and configurations tabulated in the attached span tables. (a)For ground snow no greater than 42psf Ss<_2 Og for Site Class A.B,C,&D ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf SS 5 1.Og for Site Class A.B,C,&D 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:SS<_1 5g for Site Class A.B,C. &D • 2020 Building Code of New York State(BCNYS-2020. Published in November 2019) EZ SYS° • 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30 3-2A to Figure 30.3-21 and are organized into three groups in U • Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCp).Roof zones comprising each group along with each roof zone's size and location are depicted in Figures 2 and 3 below each span table ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall NEW YORK,11952 the respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load PH:(631)779 7993 &configuration condition from the span tables,or 36' services@e2sys.com ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8`to 45` The tabulated spans are applicable when the Licence-ME-52689 following conditions are met: 7. Allowable span length in the charts may be multiplied by a factor of 1 08 if the rails are continuous over (MASTER ELECTRICIAN) Licence-HI-67461 a minimum of three spans. (SUFFOLK HOME IMPROVEMENT) 1_ Span is the distance between two adjacent roof attachment points(measured at the center of the attachment fastener) 8. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: KIM & MAHLON RUSSELL a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2/3 of end spans. 2045 LONG CREEK DR, 2 Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system) Spans are calculated b) BOSS Splice can be installed at any location within a span. SOUTHOLD, NY 11971 based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If Pv SUMMARY such conditions are encountered contact support@i ron ridge.Com. SYSTEM SIZE STC 425 X 28 =11 900 3 The underlying roof slope.measured between the roof surface and horizontal plane.is 80 to 450 (KWDC) FTC 398.1 X 28 =11.147 4 The mean roof height defined as the average of the roof eave height and the roof ridge height measured (KWACM SIZE 8 960 @240 from grade,does not exceed 30 feet. MODULES 28 JINKO SOLAR J KM425N-54HL4-8 MICRO-INV.CITY 28 5. A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the IMIC ROTeR ENPHASE 108MCa2-M-US height of the array.the distance from the module top surface to the roof surface(defined as h2),shall not UTILITY ONG ISLAND POWER AUTHORITY U PA) exceed 10". 6. Module length and area shall not exceed the maximum values listed on the respective span tables. Rev Description Date A INITIAL DESIGN 5/11/2024 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge s Flush A! UPDATED DESIGN e/7/2024 Mount Installation Manual and other applicable standards for the general roof construction practice. PROJECT# 9471 DATE DRAM 8/7/2024 r`2021 IronRidge.Inc. NY Flush Mount System Certification Letter-1 ©2021 IronRidge.Inc. NY Flush Mount System Certification Letter-2 DRAWN BY ER SHEET# PV-7 5 TITLE CERTIFICATION 28357 Industrial Blvd. Hayward, Industrial Blvd. Hayward,CA 94545 Hayward, -9 94545 RON RI DGE I 1-800-227-9523 I RON RI DGE fronRi ge.co 23 IronRidge.com IronRidge.com 10. Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations(orphan modules)using modules with a length greater than 67.5".CAMO The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting THESE DRAWINGS ARE SUBJECT TO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater Such A scenarios are shown by asterisks in the applicable span tables members. It is the responsibility of the installer or stem designer to verify the structural capacity and adequacy of the COPYRIGHT PROTECTION R I LAW. P Y Y 9 '7 P Y q Y REPRODUCTION IN ANY FORM IS b) CAMO will function within a module's design load ratings.Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CAMO meets the dimensional requirements shown in the figure below and that the module selected is RENEWABLES ENGINEERING INC. suitable for the environmental conditions of a particular project. Sincere) �'� - __ - 2 O 2 1 .O JQ.O 7 Current Y, ,tr1�NG X�� �G9 nnodule Gloss/Cep •� n " : _ - x enewabl e c 15:45: 16� Engineerinc CURRENT RENEWABLES 00 ENGINEERING INC. Zi'Ct. N(•� - -- O 1760 CHICAGO AVE SUITE ESStO J-13.RIVERSIDE CA 92507 Frame COmpolibily: - PHONE.(951)-405-1733 x=1.2-2.2 mm WWW.CRENG CO Y=15-40 mm Gang Xuan.PE CONTRACTOR INFO Senior Structural Engineer % ga Figure t CAMO Module Frame DJmensionai Requirements gm Span values for Exposed and Edge module conditions. as defined below,are included in the attached span EZSYS° tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; ELEMENT ENERGY LLC. 2 The span value determined b site winds speed and round snow load.Additional) 7470 SOUND AVENUE,MATTITUCK, ( ) p y p g y,irrespective of the lesser NEW YORK,11952 span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage PH:(631)779 7993 limitation detailed in note 9 of page 2 shall apply to the respective condition. services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 1. Exposed Module Conditions: (SUFFOLK HOME IMPROVEMENT) A module is defined as Exposed(per Section 29 4 4 of ASCE 7-16)if the distance from any of its free KIM & MAHLON RUSSELL edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave. ridge,rake,or 2045 LONG CREEK DR, hip)is greater than 0 5h(h is ASCE defined building height)AND if the distance from its free edge to any SOUTHOLD,NY 11971 other adjacent array or panel is greater than 4 feet- PV SUMMARY SYSTEM SIZE STC 425 X 28 =11 900 The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed (KWDC) Modules. RTC 3981 1 X 1 28 =11 147 SYSTEM SIZE 8 960 (9240 (K WAC) 2. Edge Module conditions: MODULES MICRO -INV CITY 26 J INKO 2s JKM4 SOLAR MICRO-IN SN-54HL4-B . MICRO ENPHASE IQ8MC-72-M-US A module is defined as an Edge Module when its distance from any side of the module to its facing INVERTER LONG ISLAND POWER AUTHORITY perimeter roof edge(such as eave,ridge,rake,or hip)is less than 2 times the height of the array(2h2) UTILITYUPA) where h2 is measured from the roof surface to the top surface of the module. The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules Rev Description Date Additionally.. if the roof edge Is the eave or ridge,only the rail nearest to that roof edge shall be considered A INITIAL DESIGN 5111v2024 for this span adjustment. A, UPDATED DESIGN 8/712024 PROJECT# 9471 C 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-3 C 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-4 DATE DRAWN 8,'7i2024 DRAWN BY ER SHEET# PV-,6 TITLE CERTIFICATION ROOF MOUNT SOLAR PERMIT PACKAGE - .` rjF NEW,,, KIM & MAHLON RUSSELL ��oO�R1 A. Z4 11 .900 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2045 LONG CREEK DR, SOUTHOLD, NY 11971 106793 Fop��FIE S IONP�F, 25 THESE DRAWNGS ARE SUBJECT TO AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES: Stamped 0909/2024 COPYRIGHT PIROTECTION BY US LAW. THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY REPRODUCTION IN ANY FORM IS POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 2020 NEW YORK STATE BUILDING CODE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES RENEWABLES ENGINEERING INC 0 2020 NEW YORK STATE RESIDENTIAL CODE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED 2020 NEW YORK STATE MECHANICAL CODE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE Q ( 2017 NATIONAL ELECTRICAL CODE UNDERSIGNED Current ,ry= 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 ReneWables 6 ALL ROOF PENETRATIONS TO BE SEALANT SEALED WITH A HIGH PERFORMANCE ROOF SEALANT • ;\ Engineering + 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL � JURISDICTION AND THE UTILITY IS OBTAINED CURRENT RENEWABLES 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, ENGINEERING INC. MECHANICAL,OR BUILDING ROOF VENTS 1760 CHICAGO AVE SUITE AHJ TOWN OF SOUTHOLD 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS J-13,RIVERSIDE CA 92507 _ THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PHONE I9511-405-1733 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED WWW CRENG CO CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S CONTRACTOR INFO INSTALLATION INSTRUCTIONS" 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA ram" UM UTILITY METER PM PRODUCTION METER REGULATIONS 12 MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. ® m SP MAIN SERVICE PANEL INv INVERTER 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. E2SYS9 BUILDING INFORMATION COMBINER SUB SUB PANEL 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. AC DISCONNECT LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE ELEMENT ENERGY LLC. 2 STORY HOUSE SINGLE FAMILY RESIDENCE NEC,THE INSTALLATION STAN DAR DS/MAN U FACTU RER'S RECOMMENDATIONS AND IF 7470 SOUND AVENUE,MATTFNCK, MODULE IQ CONTROLLER 2 PH:(631)779 7993 REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. NEW YORK,11952 IQ 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" services@e2sys.com CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U ROOF OBSTRUCTIONS ABOVE ROOF SURFACE. Licence-ME-52689 ATT BATTERY 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE (MASTER ELECTRICIAN) QH Q.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 1213 CONDUCTORS THROUGH AP N : 1000055000700005000 36"ACCESS PATHWAYS RATED FOR EXPOSURE:TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN Licence-HI-67461 18"ACCESS PATHWAYS E OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT (SUFFOLK HOME IMPROVEMENT) SHEET INDEX ESS DISCONNECT 20 MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, KIM& MAHLON RUSSELL ROOF ACCESS POINT STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO RAIL Lc LOAD CENTER THE PURPOSE INTENDED: 2045 LONG CREEK DR, PV-1.0 COVER PAGE - SOUTHOLD,NY 11971 RAFTER SEPTIC TANK LOT NO. :-0.84 ACRES PV-2.0 'SITE PLAN 0 PV SUMMARY PV-2. ROOF PLAN ATTACHMENT ��� LEACH LINES (K DC) SIZESTC 425 11 X 28 141900 MAIN BREAKER PV-3.0 ;STRUCTURAL BE ENCLOSURE PROPANE TANK WIND SPEED 128 PTc 3s6., x z6 = ,,a7 SYSTEM SIZE _ 8.960 0240 PV-4.0 ELECTRICAL 3LD AUTOMATIC TRANSFER WELL SNOW LOAD 25 wnc) TS MODULES - 28 11NK0 SOLAR PV-4.1 ELECTRICAL SLD SWITCH Z MICRO-INv CITY z5 EXPOSURE CATEGORY C 1KM425N-54HL4-B O POWER LINES STRUCTURAL NOTES : PV-4.2 ELECTRICAL PHOTOS O MICRO ENPHASE I D POWER P PERMANENT ANCHOR INVERTER NO LADDER ACCESS 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE [LONG)ISLAND POWER AUTHORITY PV-5.0 BOM 0 (STEEP GRADE OF THE ROOF FRAMING SUPPORTING THE PROPOSED PV UTILITY LIPA) O TEMPORARY ANCHOR OR GROUND LEVEL PV-6.0 SIGNAGE & PLACARD OBSTRUCTIONS) INSTALLATION ONLY. IL INSTALLER LADDER 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. PV-7.0 SPECS+ "z As GAS SHUT OFF 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS MUST Rev Desviption Date U511112024 FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. A UPDATINITIAL ED ESIGN 0806/202 ! S❑ STUB-OUT Hzo WATER SHUT OFF A, UPDATED DESIGN o6/os/zoza ' 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS ® A.2 UPDATED DESIGN 9l9/2024 SKYLIGHT O SERVICE DROP REPORT FOR ADDITIONAL INFORMATION. PROJECT# 9471 5. PRIOR TO THE COMMENCEMENT OF WORK, THE SOLAR INSTALLER DATE DRAWN 9/9/2024 RESTRICTED ACCESS JUNCTION BOX SHALL VERIFY THE ROOF FRAMING INFORMATION BEFORE DRAWN BY ER 130ding Department CONDUIT INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY I SHEET# PV-,0 Town Ge Southold INCONSISTENCY BETWEEN SITE VERIFICATION AND THE FOLLOWING: TITLE 2x6 RAFTERS @ 16" OC SPACING WITH A MAX UNSUPPORTED SPAN COVER PAGE EQUAL TO OR LESS THAN 26 FT. R324.6.1 PATHWAYS: WIND SPEED : 128 NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND SEPARATE ROOF PLANES, SNOW LOAD 25 FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. EXPOSURE CATEGORY C _ 67r_grr AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR �_-_ UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. PROPERTY LINE �- FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM "�__ I/ MSP MAIN SERVICE PANEL 361NCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING •• a COMBINER THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS \`• AC DISCONNECT WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT. •� MODULE R324.6.2 SETBACK AT RIDGE: \ ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 I r PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN \ I I ® 36„ACCESS PATHWAYS AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A / r I r ` I MSP I THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. 97 -3 , i COPYRIGHT PROTECTION BY US LAW. \ % I I 18"ACCESS PATHWAYS REPRODUCTION IN ANY FORM IS FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 t • EXPRESSLY FORBIDDEN WITHOUT PRIOR PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A •\ ��� I I N APPROVAL FROM CURRENT 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A ROOF ACCESS POINT WRITTEN RENEWABLES ENGINEERING INC. HORIZONTAL RIDGE. I `• I AC R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS \• I I Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE � \ / Renewable s AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE •\ // ENLARGED VIEW Engineering PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. NOTES: / CURRENT RENEWABLES 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED I `• ENGINEERING INC. ROOF ACCESS POINT � / 1760 CHICAGO AVE SUITE ON ACTUAL SITE CONDITION AND I / / J-13,RIVERSIDE CA 92507 MEASUREMENTS. ROOF OBSTRUCTION WWW CRNG CO // PHONE E1733 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS / INCORPORATED INTO THE 2017 NEC AND UL ENLARGED VIEW I � 1 n \ CONTRACTOR INFO STANDARD 1741. 3. EXISTING ROOF VENT SHOULD NOT BE / COVERED. I C // �I r II [mum 38 -1 E2SYS9 I AC ELEMENT ENERGY LLC. I I If FENCE 0 DRIVEWAY % 7470 SOUND AVENUE,MATTfTUCK, � NEW YORK,11952 ROOF LINE I PH:(631)779 7993 I '•t '; W services@e2sys.cos.com Licence-ME-52689 ROOF ACCESS POINT (MASTER ELECTRICIAN) .: Licence-HI-67461 I ,�. %v t..,.� / fVUnn (SUFFOLK HOME IMPROVEMENT) <+ : KIM & MAHLON RUSSELL i I ; O 2045 LONG CREEK DR, I � OF NEW y J SOUTHOLD,NY 11971 C:,`Q, �RI A ( 0� PV SUMMARY SYSTEM SIZE STC 425 X 28 =11.900 �O0 �N 90F (KWDC) PTC 398.1 X 26 =11.147 TYSTE 1 112 -11 KWACM SIZE 8.960 @240 r rr r I 4J 11NKO SOLAR n W MODULES 28 •^4 � U = 1KM425N-54HL4$ An MICRO-INV.QTY 28 106793 MICRO ENPHASE IQ8MC-72-M-US INVERTER SSIONP� ONG ISLAND POWER AUTHORITY UTILITY - LI PA) i Exp:9/30/2025 PROPERTY LINE Stamped 09/09/2024 Rev Description Date A INITIAL DESIGN 5/11/2024 -�_ , At UPDATED DESIGN 08/06/2024 A 2 UPDATED DESIGN 9/9/2024 105r_1 ►, - - -- _ _ /I -�- PROJECT# 9471 � ,` � �` DATE DRAWN 9/9/2024 •1 w DRAWN BY ER PLAN SITE ��` 1 SHEET# PV-2.0 TITLE )__SCALE: 1/32" = 11-OII SITE PLAN ARRAY AREA LEGEND ARRAY ROOF ROOF TOTAL #OF AREA AREA ROOF AZIMUTH AREA AREA — uM UTILITY METER MODULES (Sq.Ft.) (Sq.Ft.) COVERED BY COVERED BY ARRAY(%) ARRAY(%) EW MAIN SERVICE PANEL #1 232° 13 273.26 4036 6.77 ,`Q� Rt A SP #2 142° 9 189.18 4036 4.69 14.58 h�00� s �4OF c� COMBINER #3 142° 6 126.12 4036 3.12 * * �C AC DISCONNECT r ( MODULE f^2 `" = ROOF OBSTRUCTIONS `r 106793 � 36"ACCESS PATHWAYS oA��FESSIONP�� THESE DRAWINGS ARE SUBJECT TO ® 18"ACCESS PATHWAYS COPYRIGHT PROTECTION BY US LAW. Exp:9/30/2025 REPRODUCTION IN ANY FORM IS Stamped 09/09/2024 M S P ROOF ACCESS POINT EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RAIL RENEWABLES ENGINEERING INC RAFTER Current AC ATTACHMENT Renewables 6 Engineering \ CURRENT RENEWABLES ENGINEERING INC. 1760 C AVE SUITE ENLARGED VIEW J-13 RIVERSIDE CA 92507 PHONE:(951)405-1733 W WW.CRENG CO —� CONTRACTORINFO r� UM dom CZSYSA I / ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, Y NEW YORK,11952 I I I LU PH:(631)779 7993 • uen W services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) K. f V n (SUFFOLK HOME IMPROVEMENT) YC z KIM & MAHLON RUSSELL 2045 LONG CREEK DR, SOUTHOLD,NY 11971 [ I PV SUMMARY ? I SYSTEM SIZE KWDC) STC 425 X 28 = 1.900 J___ r — PTC 1 398.1 X 1 28 =11.147 SYSTEM SIZE 8,960 0240 (KWAC) ■ I I MODULES 28 1LAR KM429N-544HL4$ I VV I ROOF#3 — MICRO-INV.QTV 28 — (N)28 JINKO SOLAR JKM425N-54HL4-B MICRO ENPHASE IQSMC-72-M-US INVERTER LONG ISLAND POWER AUTHORITY UTILITY IPA) ACI Rev Description Date A INITIAL DESIGN 5/112024 Al UPDATED DESIGN Lj ENLARGED VIEW I A2 UPDATED DESIGN 9 9 2024 2 4 PROJECT# 9471 DATE DRAWN 9192024 DRAWN BY ER ROOF#1 ROO F 2L SHEET# PV-21 TITLE SCALE: 313ZPLAN= 1'-0" ROOF PLAN TABLE 1 TABLE 2 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG S2 ATTACHMENT IRONRIDGE QUICKMOUNT HALO ULTRA 16" 64" 24" GRIP ROOF 1 32' COMP SHINGLE RAFTER 2X10 s3 RAIL IRONRIDGE XR-100 RAIL ROOF 2 37o COMP SHINGLE RAFTER 2X10 16" 64" 24" ROOF 3 26° COMP SHINGLE RAFTER 2X10 16" 64" 24" NEW y0 o0�R1 A' (q� 'P� THESE DRAWINGS ARE SUBJECT TO COPYRIGHT* F * REPRODUCTION O NE ANY OFORM IN BY US S EXPRESSLY FORBIDDEN WITHOUT PRIOR r tic WRITTEN APPROVAL FROM CURRENT 4! RENEWABLES ENGINEERING INC. Z 106793 ��� Current p'�oFEss►oNa Renewable Engineering Exp:9/30/2025 Stamped 09/09/2024 CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE MODULE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO S3 CONTRACTORINFO TABLE : PENETRATION s2GUIDE FOR INSTALL mom ROOF TWO OR MORE ROWS OF PANELS EZSYSA ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 2.5"MIN.EMBED. PH:(631)779 7993 I 1 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) 2 -#14 X 3" SELF DRILLING Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) STRUCTURAL SCREWS TO I 1 1 1 I I I 51 EXISTING STRUCTURE I I 1 f I 1 I I I I I I I I I I I I I KIM & MAHLON RUSSELL 2045 LONG CREEK DR, SOUTHOLD,NY 11971 ENLARGED VIEW STACKED STAGGERED FULLY STAGGERED PV SUMMARY SYSTEM SIZE STC 425 X 28 = 1,900 (K WDC) ONE ROW OF PANELS PTc 398.1 X 28 SYSTEM SIZE(KWAC) 8960 @240 OLAR MODULE MODULES 28 J 5 JKM4INKO SN-54-54HL4$ MICRO-INV.OTY 28 1 1 1 1 I I 1 I 1 I 1 I MICRO ENPHASE IQSMC-72-M-US I I 1 1 I I 1 1 1 I 1 I INVERTER UTILITY ONG ISLAND POWER AUTHORITY SEE ENLARGED VIEW uPAI FULLY STAGGERED STACKED/STAGGERED Rev Description Date A INITIAL DESIGN 5/11/2024 Al UPDATED DESIGN 08/06/2024 ROOF A.2 UPDATED DESIGN 9/9/2024 PROJECT# 9471 DATE DRAWN 9/9/2024 ATTACHMENT DETAILS DRAWN BY ER SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING MODULE JINKO SOLAR OF NE(.y ELECTRICAL EQUIPMENT LIST NUFACTURER �O��MAN�' MAX.CONTINUOUS OUTPUT 1.33A @ 240V �� J S.NO. ITEMS DESCRIPTION QTY. MA "p GjP4yC �� 37.24 X 1.25 = 46.55AMPS 60A FUSES-OK MODULE MODEL JKM425N-54HL4-8 JINKO SOLAR * 4 G 1 PV MODULE 28 _ JKM425N-54HL4-B PSEGLI ACCOUNT NUMBER 9670589902 r— D LU MODULE(W) 425 W METER NUMBER 98610001 m w MODULE PTC(W) 398.1 2 099128 = 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 28 N �C9 MODULE Isc(A) 13.58 4 4 crR1cP� 3 COMBINER ENPHASE COMBINER BOX 1 MODULE Voc(V) 38.95 ARO SSIONP\1 X-IQ-AM1-240-5/5C MODULE Imp(A) 13.13 60A RATED DU222RB STAMPED 09/10/2024 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 MODULE Vmp(V) 32.37 LOCKABLE NEMA 3R UL LISTED 60A FUSED RATED THESE DRAWINGS ARE SUBJECT TO FUSED AC D322NR6 SQUARED (E)UTILITY METER TO UTILITY COPYRIGHT PROTECTION BY US LAW REPRODUCTION IN ANY FORM IS 5 DISCONNECT KNIFEBLADE LOCKABLE 1 GRID EXPRESSLY FORBIDDEN WITHOUT PRIOR NEMA 3R UL LISTED WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N) ENPHASE (E)200A RATED COMBINER BOX MAIN SERVICE PANEL Current 1PH,120/240V 60HZ 1 2 3 CELL (E)200ABRP�M MAIN Renewa e5 WIRE LESS Engineering MODEM COMMS (TOP FED) CURRENT RENEWABLES 1 BRANCH OF 10 N IQ GATEWAY PV MODULE ENGINEERING CHIC GO INC. 1760 CHICAGO AVE SUITE } my' J-13.RIVERSIDE CA 92507 --------1 kN)15A� ` • PWWW.CRENG CO r -1 CONTRACTORINFO I I I •� I 2 BRANCH OF 9 (N)20A/T� LIST DECONNECTOR I UL PV MODULE N —� (N)20A I I I I (N)FUSED •� (N)20�� I I 4 (N)AC AC DISCONNECT • CZSYS9 I I I DISCONNECT I I I • L— `t-- —————— - — I I ° °,Ib • ELEMENT ENERGY LLC. L — --- — -- I L------ ----- --- 0.fb —� 7470 SOUND AVENUE,MATTITUCK, 3 BRANCH OF 9 INEW YORK, PV MODULE N ------------ PH:631) 1 77979 3 } i services@e2sys.com C Licence-ME-52689 5 (MASTER ELECTRICIAN) q B L-------------- Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 1-#6 GEC,BARE COPPER (E)GROUNDING ELECTRODE _ COATED CONDUCTOR #6 BARE COPPER KIM& MAHLON RUSSELL NOTE: 2045 LONG CREEK DR, 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS SOUTHOLD,NY 11971 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE(K WDC) src azs x za =n.9oo PTC 398.1 X 1 28 = 1.147 WIRE CALCULATION SYSTEM SIZE 8960 9240 (K WAC) STARTING ADJUSTMENT MAXIMUM 11NK0 SOLAR STARTING TEMPERATURE MODULES 28 JKM425N-54HL4-B CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INV CITY 28 CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION MORE THAN 3 CONDUCTOR APPLIED TO MICRO ENPHASE IQ8MC-72-M-US TAG DESCRIPTION APPLIED TO CITY. SIZE(AWG) SIZE&TYPE AM PACITY RATING CC) FACTOR INVERTER 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS urlLlry ONG ISLAND POWER AUTHORITY IN RACEWAY 310.15(B)(3)(a) IN RACEWAY `IPA) 6 12 SKU:Q-12-RAW-300, THHN q N/A FREE AIR 30 90° 13.3 0.96 0.8 23.04 16.63 Rev Description Date 1 8 THWN-2 BARE COPPER-(GROUND) A INITIAL DESIGN 5/11/2024 2 8 THWN-2 COPPER-(L1,L2) A, UPDATED DESIGN oaoszoza B 3/4" PVC 55 90° 37.24 0.96 1 52.80 46.55 A2 UPDATED DESIGN 9/9/2024 1 g THWN-2COPPER-(GROUND) PROJECT# 9471 DATE DRAWN 9/9/2024 3 6 THWN-2 COPPER-(L1,L2) DRAWNBY ER C 3/4"PVC 75 90° 37.24 0.96 1 72.00 46.55 1 8 THWN-2 COPPER-(GROUND) SHEET# PV.4o TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING MODULE JINKO SOLAR OF NEw ELECTRICAL EQUIPMENT LIST MANUFACTURER y MAX.CONTINUOUS OUTPUT 1.33A @ 240V C p S.NO. ITEMS DESCRIPTION QTY. �P OBE M�7�9 37.24 X 1.25 = 46.55AMPS 60A FUSES-OK MODULE MODEL JKM425N-54HL4-B .r C * l _ 1 PV MODULE JINKO SOLAR 28 JKM425N-54HL4-B PSEGLI ACCOUNT NUMBER 9670589902 D 0 MODULE(W) 425 n W METER NUMBER 98610001 m 099128 2 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 28 MODULE PTC(W) 398.1 y� MODULE Isc(A) 13.58 4 crRIGP` tv� 3 COMBINER ENPHASE COMBINER BOX 1 MODULE Voc(V) 38.95 ARO SSIONP� X-IQ-AM1-240-5/5C MODULE Imp(A) 13.13 60A RATED DU222RB STAMPED 09/10/2024 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 MODULE Vmp(V) 32.37 LOCKABLE NEMA 3R UL LISTED 60A FUSED RATED (E)UTILITY METER THESE DRAWINGS ARE SUBJECT TO 5 FUSED AC D322NRB SQUARE D 1 TO UTILITY COPYRIGHT PROTECTION R IS LAW. GRID REPRODUCTION IN ANY FORM IS DISCONNECT KNIFEBLADE LOCKABLE EXPRESSLY FORBIDDEN WITHOUT PRIOR NEMA 3R UL LISTED WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N) ENPHASE (E)200A RATED COMBINER BOX MAIN SERVICE PANEL 1 1 PH,120/240V 60HZ Current 2 3 CELL (E)200AI2PBRE MAIN Renewabies KER MODEM WIRE LESS (TOP FED) Engineering COMMS 9 9 1 BRANCH OF 10 IQ GATEWAY CURRENT RENEWABLES PV MODULE N 1760 HICAGIO AVE SNG UITE my. J-13,RIVERSIDE CA 92507 FN)15A, ` • • PHONE-.(951)-405-1733 WWW.CRENG.CO •�• CONTRACTOR INFO 2 BRANCH OF 9 (N)20��. • �, (N)LINESIDE TAP VIA UL PV MODULE /� •�i LISTED CONNECTOR N (N)20�� • •� ® n/'\ (N)FUSED •�• I (N)20 A�. 4 (N)AC AC DISCONNECT • _ DISCONNECT CZSYS9. •�:� ELEMENT ENERGY LLC. 3 BRANCH OF 9 7470 SOUND AVENUE,MATTITUCK,NEW Y PV MODULE N 11952 � PH:(631)779 7993 services@e2sys.com 5 C Licence-ME-52689 A B (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) (E)GROUNDING ELECTRODE _ CONDUCTOR #6 BARE COPPER KIM & MAHLON RUSSELL NOTE: 2045 LONG CREEK DR, 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS SOUTHOLD,NY 11971 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE STC 425 X 28 =11 900 (KWDC) PTC 398.1 X 28 = L147 WIRE CALCULATION SYSTEM SIZE 9960 @240 (K WAC) STARTING ADJUSTMENT MAXIMUM MODULES 28 JINKOSOLAR STARTING TEMPERATURE JKM425N-54HL4-B CONDUIT ALLOWABLE TEMPERATURE TAG DESCRIPTION APPLIED TO CORRECTION CONDUCTOR CONDUCTOR CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INV QTY 28 MORE THAN 3 CONDUCTOR APPLIED TO MICRO ENPHASE IQBMC-72-M-US CITY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (-C) FACTOR INVERTER 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS UTILITY ONG ISLAND POWER AUTHORITY IN RACEWAY 310.15(B)(3)(a) IN RACEWAY `IPA) 6 12 SKU: Q-12-RAW-300, THHN A N/A FREE AIR 30 90' 13.3 0.96 0.8 23.04 16.63 Rev Desaiption Date 1 8 THWN-2 BARE COPPER-(GROUND) rDRAVMBY INITIAL DESIGN 5111/2024 2 8 THWN-2 COPPER-(L1,L2) UPDATED DESIGN 08/os/2o24 B 3/4" PVC 55 90, 37.24 0.96 1 52.80 46.55 UPDATED DESIGN 9/9/2024 1 8 H - -(GROUND) 9471 3 6 THWN-2 COPPER-(L1,L2) 9/9/2024 C 3/4" PVC 75 90' 37.24 0.96 1 72.00 46.55 ER 1 8 THWN-2COPPER-(GROUND) ELECTRICAL SLD EXISTING SERVICE PANEL PHOTOS of NEW y0 MA/V/,� r ' D W m w 099128 _2 CTRIGP� ��C9 �OFESsk STAMPED 09110/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewabfes Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG.CO CONTRACTOR INFO amm EZSYS9 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL 2045 LONG CREEK DR, SOUTHOLD,NY 11971 PV SUMMARY SYSTEM SIZE STC 425 X 28 =11.900 (KWDC) PTC 398.1 X 28 = 1.147 SYSTEM SIZE _ 8.960 0240 (K WAC) MODULES 28 JINKO SOLAR 1 KM425N-54HL4-B MICRO-INV.OTY 28 MICRO ENPHASE IQSMC-72-M-US INVERTER UTILITY ONG ISLAND POWER AUTHORITY LIPA) Rev Description Date A INITIAL DESIGN 5/11/2024 Al UPDATED DESIGN 08ID612024 A.2 UPDATED DESIGN 9/9/2024 PROJECT# 9471 DATE DRAWN 9/9/2024 DRAWN BY ER rSHEET# PV-4.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST pFNEI�,y MA o ELECTRICAL EQUIPMENTS w m D99128 a QTY. PART TYPE PART NUMBER DESCRIPTION 28 MODULE JKM425N-54HL4-B J IN KO SOLAR JKM425N-54HL4-B o CTRIGP 28 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US ADO SSiONP� 1 FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED STAMPED 09/10/2024 1 COMBINER X-IQ-AM1-240-5 5C ENPHASE IQ COMBINER 5 5C 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS COPYRIGHT PROT ARE SUBJECT TO TECTION BY US LAW REPRODUCTION IN ANY FORM IS 1 AC DISCONNECT DU222RB 60A RATED 240VAC NEMA 3R UL LISTED EXPRESSLY FORB FROM CUR M CUR WITHOUT PRIOR WRITTEN APPROVAL FROM RENEWABLES ENGINEERING INC. Current I-newables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG CO CONTRACTORINFO / QTY. PART TYPE PART NUMBER BREAKER FUSES DESCRIPTION � ® n CZSYS.- 1 FUSES 60A FUSES GENERAL 60A FUSES 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ELEMENT AVENUE, LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 service5@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL RACKING 2045 LONG CREEK DR, QTY. PART TYPE PART NUMBER DESCRIPTION SOUTHOLD,NY 11971 PVSUMMARY 24 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK KWDC)(SYSTE SIZE STC 425 X 28 = 1.900 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 Kwoo, PTC 398.1 X 1 28 = 1.147 74 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK (KWACM SIZE 8960 @240 36 CLAMPS & GROUNDING UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK KM45LAR N-54 MODULES 28 JINKO L4-B MICRO-INV.OTY 28 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE INVERTER LONG POWER_C_RO ENPHASE 68 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP,BLACK UTILITY LING ISLAND PowBR AUTHORITY URA Rev DescripWn Date LINITIAL DESIGN 5/1112024 UPDATED DESIGN 08/06/2024 UPDATED DESIGN 9t92024 9471 919/2024 ER PV-5.D TITLE BOM CAUTION ��°FNEwy P of MANj O,Q MULTIPLE SOURCE OF POWER co U G r— ' D W n r————- 2 }�099912B 2 I D I I � c� �———————— OA � crR1cP v —— R SSI PHOTOVOLTAIC STAMPED 09/10/2024 • ■■ ■ ■ • V AC DISCONNECT COMBINER 690.1 2 THESE DRAWINGS ARE SUBJECT COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current TURN RAPID L — PV SYSTEM AC DISCONNECTRenewables SHUTDOWN SWITCH TO RATED AC OUTPUT CURRENT ' t PV ARRAY Engineering THE "OFF" POSITION TO AC AC NORMAL OPERATING VOLTAGE I , VOLTS CURRENT RENEWABLES ENGINEERING INC. SHUT DOWN PV SYSTEM 690.14,690.15,690.54 1780 RIVERSICHICAGDE AVE SUITE / PHONE RIVERSIDE-1 92507 PHONE(951)-4057733 AND REDUCE SHOCK WWW CRENG CO HAZARD IN THE ARRAY A — CONTRACTOR INFO ---- 690.56(C)(1)(B) I l/ I UTILITY METER SECOND SOURCE IS PHOTO-VOLTAIC SYSTEM ■ , AC OUTPUT ■ CURRENT ■ ■ AC DISCONNECT � CZ�YS�4 NORMALAC OPERATING • . 40 • T MAIN SERVICE PANEL ELEMENT ENERGY LLC. 7470 SOD AV NUE,MATTITUCK, 690 54 NEW YORK,11952 OPTIONAL SOLAR LOAD CENTER LONG CREEK DR PH:(631)779 7993 services@e2sys.com ARRAY PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL Licence-ME-52689 EECT PANEL IS AC DISCONNECT PER NEC690.17 (MASTE LienceLHII-67461N) (SUFFOLK HOME IMPROVEMENT) KIM & MAHLON RUSSELL J/B 2045 LONG CREEK DR, SOUTHOLD,NY 11971 PV SUMMARY INVE■ ■ OUTPUT . CONNECTION • SYSTEM SIZE K WDC) STC 425 X 28 =11.900 • • RELOCATE • . PTC 398.1 X 28 = L147 THIS NEC 690.31(G)(3)&(4),CRC R324.7 SYSTEM SIZE g g60 a2ao (K WAC) OVERCURRIENT DEVICEANKO I � � MODULES 28 KM425Nb4HL4-B (UNLESS BUSBAR IS FULLY RATED) LAR L — PHOTOVOLTAIC ■• ■ SOURCE MICRO-INv.OTv ze 705.12(D)(2) NOTES. MICRO ENPHASE IQ8MC-72-M-US INVERTER UTILITY ONG ISLAND POWER AUTHORITY LI PA) EVERY 10'ON CONDUIT AND ENCLOSURES 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A INITIAL DESIGN 5/11/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. Al UPDATED DESIGN 08/06/2024 B. RED BACKGROUND COLOR WHITE TEXT AND LINE A2 UPDATED DESIGN 9/9/2024 WORK. LDATE OJECT# 9471 C. AERIAL FONT. DRAWN 9i9,2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN AWN BY ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE EET# PV-60 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. SoLan www.jinkosolar.com a n«O Engineering Drawings • • • •- • - ' • &Mding ran Trost in Saar riger Neo N-type r. _ - c.nen,vdhoo•srwa varmve 1•^4•raWre O•P•"�•N ------ c_W 5W) •c vmc.hn� - rb I ,e 54HL4-B ?` _ w • m � ,m_. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 425 Watt • REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT s RENEWABLE$ENGINEERING INC. ALL-BLACK MODULE - e s m s a z s s r Current r N-r s K ��n� � "- _ -�_ - enewable Positive power tolerance of 0-+3% Engineering CURRENT RENEWABLES IEC61215120161,IEC61730(2016) s- ENGINEERING INC. tSO9001:2015:Quality Management System Mechanical Characteristics 1760 CHICAGO AVE SUITE �-v — J-13,RIVERSIDE CA 92507 ISO 14001:2015:Environment Management System nc. r 1 'e$" "` Ce6 Type PHONE:(951)-405-1733 -i WMW.CRENG.CO occupational health and safety rnonagement systems s "" Dimensions 1722.1134r30mm i67.79.44.65.1.18 inch) CONTRACTOR INFO 32nnRolen g.'• •• ConfigurationFront Gass High Transmission.L to ernpee GITKey Features Ac��n=0- M. gown* Junction 8ohc p�t:�d CZSYS0 5MBB Technology a Not 2 0 Technology ® Better light I appng acid cur improve rent collection to prove HOT -e N-type modjle with Hot 2-0 technology has better ELEMENT ENERGY LLC. rrockde power outptrtand reliability- 2.0 reyabifty and tower UD/LETID. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 SPECIFICATIONSPH:(631)779 7993 services@e2sys.com Module Type JKM425N-54H_4-3 Licence-ME-52689 \ PID R (MASTER ELECTRICIAN) etshilance Enhanced MechardCal Load I• +a++ Licence-HI-67461 Excellent Anti-PID performance guarantee via a Certified to withstand:wind b axiad(2400 Pascal)and snow M u-Powe•(PmmQ 425wp 320wp (SUFFOLK HOME IMPROVEMENT) ® optimized mass-productton process and matenols s�isrbe control IOOd(5400 Pascaq. KIM & MAHLON RUSSELL Mawmxln Power Current Itrpl 13.13A 10-WA 2045 LONG CREEK DR, SOUTHOLD,NY 11971 SFnarlctaxt Currant(ec) 13-%A 10.96A Durat�R m m Oy AgakW Extreme Environerdal - /1 g��, lthg - - - N - - -- - SYSTEM SIZE Q. PV SUMMARY ® Cond>tlOni �1 V R7>� vaerrnE aLNSITv' Opera TenPuahJre(C) -40°C-+t15°C (KWDC) STC 425 X 28 =11.900 High salt mist and ammonia resistance. PTC 398.1 X 28 =11 147 MaiiiiM/m Series fuse rating 25A SYSTEM SIZE -K WAC) 8 960 (l9;240 ( `- - MODULES 28 11NKO SOLAR TenpJesohxe coefficients of I'max _0 n/`C 1KM425N-54HL4-B MICRO-INV.CITY 28 LINEAR PERFORMANCE WARRANTY MICRO ONGI L I ISLAND AUTHORITY Temperature ccetfinaerds nN 1sc 0,045gpC INVERTER UTILITY LONG ISLAND POWER AUTHORITY LIPA) m 100% 9996 25 Year Product Warranty y� •STC: "Hm:Irradiance I OOOW/m' Cell Temperature 25•C AM=1.5 Rev Description Date NOCT Irradiance 8WW/m' Ambient Temperature A INITIAL DESIGN 5/112024 30 Year Linear Power warranty = perature 20°C � AM=1.5 Wind Speed 1 m/s Al UPDATED DESIGN 08/06/2024 87 4% A.2 UPDATED DESIGN 9/92024 PROJECT# 9471 0 11aft Yeas 0.40%o Annual Degradation Over 30 years DATE DRAWN 9/92024 12 30 CQ023 Jinko Solar Co.,Ltd.All rights reserved. Specifications included in this datosheet are subject to change without notice. JKM405-425N-54HL4-B-F3C2-EN DRAWN BY E.R Dotasheet valid in L-urope only. SHEET# PV-7.0 TITLE MODULE SPEC ENPHASE. IQ8MC Microinverter INPUT DATA IDC UNITS Commonly used module pairings w 260-460 To meet compatibility,PV modules must be within the following max.input DC voltage and max.module I_ wModuie com patibility Module compatibiity can be checked at httpsJ/enphase.com/installers/microimerie,s/caiwialor. MPPF voltage range v 25-45 Operating range V 110-58 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Min_/Max.start voltage v 22/59 REPRODUCTION IN ANY FORM IS -- - -- -- --- - - - -- - --- - --- - - EXPRESSLY FORBIDDEN WITHOUT PRIOR Max.input DC voltage v 6o WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.corrtbriaa operating DC crarart A tt Max.ini DC short-circuit current A --- 25 Current Max.module!. A 2O Renewable _ - Overvoltage class DC port R DC port backfeed current mA D Engineering 16 PV array configuration Ungrounded array:no additional DC side protection required:AC side protection requires max 20 A per branch circuit CURRENT RENEWABLE$ ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 Peak output power 1M 330 315 PHONE:(951)405-1733 ._. __.... WWW.CRENG.CO WltoorilYuous output power of 32D 310 Nominal grid voltage v 2q,apR-plraa 0.-U.180' 208.single-phase CONTRACTOR INFO 1Q8MC Microinverter - -- ---- - 5-4 - - - - --- - - -- ------- Easy to install Min./Max.grid voltage- v 211-284 183-229 • Lightweight and compact with plug- Max.continuous output cunem A 1.33 1-49 Our newest 108 Series Microinverters are the indlutry'sfirst microgrid-forming'.software- and-play connectors defined microinverters with split-phase power conversion capability to convert DC power to Nominal frequency fb 60 id 13 ral AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary • Power line communication(PLC) Extended frequency range He 47-68 ��S / S� application-specfic integrated circuit(ASIC).which enables the microinverter to operate in between components _ _ ___—_ —__ _ __ - _-- - _— grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed AC short circuit fault current over three • Faster installation with simple two-wire A� 2J0 digital logic and has superfast response tildes to changing loads and grid events.alleviating cycles cabling ELEMENT ENERGY LLC. constraints on battery sizing for home energy systems. Max.units per 20 A(L-L)branch circuit' 12 10 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 High productivity and reliability Total harmonic distortion r5 PH:(631)779 7993 phase Produces power even when the grid is services@e2sys.com • down* Overvottage class AC port ■ Licence-ME-52689 (MASTER ELECTRICIAN) • More than one million cumulative hours AC port backfaed current mA 18 Licence-HI-67461 of testing Power factor setting 7.0 (SUFFOLK HOME IMPROVEMENT) Part of the Enphase Energy System. 108 Series Microinverters redefine Class 11 double-insulated enclosure Grid-tied poser factor(adjustable) O-BS leading...0.85 lagging K I M& M AH LO N R U SS E L L 108 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the 10 Batts 10 Gateway,and the million cumulative hours of power-on PV modules Peak efficiency Battery. Y pQ __ ---- — -- -- % 974 _ _- _ ----9 2 _ - -.. 2045 LONG CREEK DR, Enpflase ADD monitoring and analysis testing,enabling an industry-leading CEC weighted efficienty, 97.0 96.5 SOUTHOLD,NY 11971 software. Iimitedwarrarrtyofupto25years.ft Microgrid-forming Nighttime power consumption mw 33 25 PV SUMMARY Complies with the latest advanced grid MECHAWCAL DATA UNITS SYSTEM SIZE SupAmbient temperature ram __ STC 425 X 26 = 1.900 • Remote automatic u _ -d0'C to 65`C(-40"F to 149`F) (K WDC) updates for the PTC 398.1 1XI 29 = 1.147 latest grid requirements Relative humidity range 4%to 100%(cca densmg) SYSTEM SIZE Configurable to support a wide range DC connector type 8til"UC4 (KWAC) 8.960 Q240 11NKO SOLAR of grid profiles Dimensions(H•W•D}Weight 212 mm(8.31•T75 mm(6.91.302 min27:(1 1.1 kg(2.43 bs) 1KM425N-54HL4-8 Connect PV modules quickly and easily I08 Series Microinverters are UL Listed • M CA Rule 21(UL 1741-SA)and IEEE Natural convection-rotas MICRO CITY 28 to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets ue a Cooling _ ICRO ENPHASE IQ8MC-72-M-US integrated MC4 Connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for tAetloodiorlKpollution J,g Yes:PD3 INVERTER installed according to the manufacturer's UTILITY ONG ISLAND POWER AUTHORITY instructions Errebwa� Class II double-insulated.corrosion-resistant polymeric enclosure LIPA) NOTE: 108 M—m tws cannot be mi.ed togerhe,with Environ.category.UV exposure rating NEMA Type 6:outdoor Pre—generations of Enphase micr im—ters COMPLIANCE (1075enas.106 series.etc.)m the same system. Rev Description Date 10 Gar—,a regmred to change the deft grid CA Rule 21(UL 1741-SA).UL 52109-1.IEEE 15472018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 A INITIAL DESIGN 5/112024 •Meets UL 1741 only when rttetalled w,m.10 Sysrem Controller 2 and 3 profile at the time of mstaustiun to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014.NEC 2017.NEC 2020.and NEC 2023 section 690.12 and Aumo i y Having Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. A.1 UPDATED DESIGN 0 8/0 612 0 2 4 A.2 UPDATED DESIGN 9/9/2024 C2023Enphgy.An renghts —d.E ese.npntheeend CCbm.gIQandcarta,nothwr rks istedat _ (1)N cedoenlor DC/AC,at,c.aee Ener ere hadwnark,d Enphese Energy.Inc.in the LIS and other counties. (2)Nominal voltage range can be extenoed beyond nominal N required by the utility. PROJECT# 9471 Data subject to"nW IQSMC-MC4-DSH-00049-3A-EN-US-2023-10-16 (3)Limits may varv.Ref,,to low,equirements to define the numbs.of mi—i—des per branch in your area. IQSMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 DATE DRAWN 9/9/2p24 DRAWN BY ER SHEET# PV-7.1 TITLE MICROINVERTER re SPEC IQ Combiner 5/5C THESE DRAWINGS ARE SUBJECT TO ENPHASE. 0 asae,ws.,tasa.lrreu.etn N.y.:zos s3sen).lhmo.ing COPYRIGHT PROTECTION BY US LAW. te.mw REPRODUCTION IN ANY FORM IS Tsmttaseel EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT gfa,rbr5wmq(iewrr PeAed vcvtbord b•n(aaa(ed•...�..a�wv = A(ern�s.•e.y. �vcb4ecf•pEbteE1 RENEWABLES ENGINEERING INC. O f:aeb�SQ�AieF21D9 1eAsnpt•AB1CQ.1D aG51U.mserpmn••oemregfz l5%)aiEgBsvaro•eiveq(f13%t e,d,Asedeer ad�efridmdAea lover � IYYYmreeckon.pleskeAteliltl q Cmber SC aN:q(ieeeeev preaed crrur bond for rmep�ed mews PV o•o0eom _-....-_ _ _ _.. 71� Gdaweeweae�YreYo Or1a.MtfLvertlydiBMtyp.RPekokar�eor.efen .;mbrSC(ai(}4n-Zl65Ci nera•aip(.N51 C1210 e0.5%1.mnYerptun^c•tor^P(s15%)mOganle•v^�(om9(a15%) Current eeY9®E•Vrelk'bfe(Aeit ul,Y•modsn(CEL(1eA'IEYi(�fJ6-Se-0bl 4ubaae/w - 20A m50AbWer eladFYmINMBmppere}debe ,eNr rdmdaba np eoAEreekrbe J•ipelmVOMC viplmdam enewables bab. bra>..� w� .. eea�aed A* ,a Engineering manepr•rre d tti E•olwq srse•r Bait-e+C1RL Srmm Corrovtr 3/3G. eee....r�<e-a•.n.e r1 xwa+t.ett,e�.etrmn..:�.bonw nss.araos.en.. ^fie tty fenhv eMeyyat(xt.g0eeerrrbWoeratl 1.201 beebn b eeuiq q Sern eAoae,�m•..rdgtvrr AVi w m2-eooe+..twot.a+ CURRENT RENEWABLES q Gae�,a� cem,:a..i...lyoia to A/bA ENGINEERING INC. aosrmmct en...d•«w.ra�mw�ect.ao�,.e.wmos% i,�rew.s� aozmromta,rewuariseir)-a.ao•..aewtre>rp.aeewn.:r..w 1760 CHICAGO AVE SUITE x-10-Ayt-240-5 _— - _- _- —... J-13.RIVERSIDE CA 92507 x-K)-Alli}240-5C c�oro„cr r o�,y(,o,,,.we,.,vd.••p cn rwoee wn v.sw..�,•m.omss% om PHONE.(951)-405-1733 gt(etbr R one---e.rkydeeeeT,sifP.e.dn(hebo.euaa.e•ym 1./% W W W.CRENG.CO Oned• 9.Eal.nmw,poea�uewfiiato ^a.bore caca borer«...em•m..rma..negsni.•�eanar IQ Combiner 5/5C E� �-�(�kecis)ufPeir.ne�d.lneee�.ee�gmtk• CONTRACTOR INFO E+V�e(aabietaera may wd:q CorrEne•%) lB-hued LTE11(caMW moden(CFLLYOOEYiN-065P-05lwC•a S(.Y TYd,sdm P� H4Peee CbW�tlreebr�t Theq(-.artYr�/7Cm®MOgs Ydwcarnw.lbraµ/pnent krm aYrrge enaoa✓eand �i (v-weum tr! some m,(.a needsab CiRlb�•tl Yabie Coact QLlN00E\FYF06-lD-0SerCBL/00Bl-Mr-t1BaT45ti iW�eMOG1e%�etlQ ebmn�ae Kl SerceYCrCrYslen andKl GeteeaY easmamPnWptOvl6tpeaorbetenL w k.1w 10 Ge yfor PpteIVO _ DgWepll/WAputbadepumravem pre+kad ePYelfonlnr oonPeaileppEodSyr Canbrwr 3f3G dK)ButmvW caemrrcabon ud eontrd ppneuedwkd etch mddw" pli IOS 10 Corwroter 3/3G Bed toaatterY 5P. CF1lY00FY-YFObSP-05 KrbriLiE�fIc1We•mabm�lme5-w•iibdledW a(en (661D for Yode Coniea (CELL s DE"iibEYeC t -"�SP-05).orr1V (Fc11100EYi606at-05 lfi-ueea tiFil�caii�noes,n w�meS�ai6'eva o�•' Msm oarrt lAPl move Fv mn dv�Eetr•tlrgGae.ereman,obb ae.ee.ve�q As Eior•oe Mab bo e� asm thegCa•nrr 5/SG abr9 utlh(05wYS YlvdrrwWes.K2 A'mnn C-11w33G and w 'Q Cdrdnu 5C Yeee•r9PVY (boiwo Corr _Cfs.aesq 6Yu C'..mdane Pohe.�o.C+ Kl astt 5VP—Amw With,m wp grd-ear F,,Oa EnwW sv�.re .S�s,�* r Wk CZSYS EthaneLaeArrr Srwor4f BRZ1b6fit2]0&atleRllaeacutbsEracarouOre wYiloEOneru Ibee•M mnnvl�on YOIrDtlY (?rtveoreee�sbeeoea AErpwi BW(-qe-2-ZIJV.Bfe(-i5A-1-21(IY.9R-10A-8-1lGIf.9R-t5/'ZP-2lM$eed '� Proeedes pradretbrrnreiung ?AOV-811mra dYrr n'Ilccauorue'eeelionl Wee eN Mermh[�e_//aerlooeev/wrWeacwn (rererec Bade)and tatureiwnon ____ mavm.iry aA-sot�Es tYtAveere eoW MwYfor gtbe,Nur Y5C ,�,eo, tbb•mn�de 1v kra�AP1 ELEMENT ENERGY LLC. u�Nt�-0cars pG.�r�+.-�m..ta.��Y(eewawlb,c�o-..s/sc 7470 SOUND AVENUE,MATTITUCK, E'^'aO("'ees ago-Neap-mn lmm.n.dm•e.mra+mE,mnat�..r..a,a:(a.r.at.�n.r,.di NEW YORK,11952 q SeelwlboYMrYrs fO SyAase ppbaw 3/3G Yusps to oru ,d MUCGrtRed q�°^e°'� LL1HI.GeMM,3eC]2SMo.%fltTpelr('3A P✓16t�a&ICESON 1i,wi:0h po.«.d en..(Orld,emylO Sexes P de.+. .g dwsercu.eaction trertee services@e2sys.com E�apareereers oos.Kn.am ne seems) dew.(ASDjtumooruty by uso�Eur�Ncs•n�No.sno-L ct�tsn:zoeac rsa-s(a rFsi d<ernetrabeevar 17.w IMS Qom r Wllol de wftvrdfeiaesand Srpp—tronpm.ba arcade •emv m• qc P,m,ms 05(wP.-k—m Licence-ME-52689 ePere.e entry eernfKees/trarenaurp Os nP(roenergv sreaee wt.ge txoruo weso(a ap6sn ham g.d taa.e.mbedcw Poe,e� s'pp°'*+Wm1or 2roois bra' (MASTER ELECTRICIAN =cult to 240 VAC Pkgo- breekua ®m••mw '�• q5,—C_3/ scl000nic3wusot 5C20DGnic2eousm Licence-HI-67461 trotevdudedf Fai:aee•,.Mry otAK: gamrr� geATt(in.,sP- (SUFFOLK HOME IMPROVEMENT) -- .eoAtpwwtrmch wa.tr _ Yavnmraresr,aaor•a•e•+u0(ePetram PY/am•eoe) 6tA rePYee(Yr lG6 q].am rm BetlaYa�llw eEempdbasedvr�paemneg ----- KIM& MAHLON RUSSELL fa eneyW�setup Gre•cn ceoffi(mw ewaYorge: uPtokae 2-pobEmneP esr�denear Pveru'a:(W)O•eNss oi.(na eraaededl er�..otar ta.�koA.(naee.•..,gaca) eoAas�a.a°er`raoe.'�es°"'mgG.m�v°•°m`�"r°°° 2045 LONG CREEK DR, R q Caee+v oreYr g A w 6 A any GE/5r•eea•Faton.audeo •DuraWaNRTi.-certlfiedNElAAtvpe3R SOUTHOLD,NY 11971 --- er�baae P,oeeemnwn9 L? 2GOAaofdaee Pe+sWetl erd wWlmgGeewry q BeEmry SP IO lAad Cornrdsr PV SUMMARY FJlrntePamdACbe(tmr T'emte.mckdessa (lelpevm•i�eeraxr*Pp ^"" s-w•un:ted wo..anh cm+vgv.•nv+ro•^ie c':C-_1oe-c:a1P1 awd2oo/.dYro-etrteas•srt trandam.•eencEew.�mfnabm fiad.gdaraaiM lOaD-9AT Miaowwerters long a grid ou(ege W op0n -Two rears ebor r-knbeseerre.a gfWWerwernp LR 20GA dmq-alylseurwabwbrr�bgB6(erEueiuir4eeldede,flfrtlnkoa dr�9i�eer+rrpten urd ve(a9 p,.g wv..W.kAdfahoee• _-- SYSTEM (KWDC) STC 425 X 28 =11.900 Dattnry tNe me K?Cwr,bYu.SKIN -ULtla 4Ld PTC 398.1 X 28 =11.147 ® O SYSTEM SIZE 8.960 9240 (K WAC) Syesr ODULES 28 JINKO SOLAR •y„-.,n-cw..,a.uro.serer.ak..rr..weeo. ..r.(�.isr.nn.(a(�rur,ar�m�..,da. 1KM42SN-54HL4$ h"w MICRO-INV.OTY 28 wwfaetty 02023Eepbe.EirrpY.Nripflereeerrad Behr tleeW CC locos K7 eroosree•oNmrrada brodal MICRO INVERTER ENPHASE IQ8MC-72-M-US Dana//erduamnJtrednuKuem-au4eF�s1•ad�•e•b o!F.p•e.e Er�p.u•.ntle l6 re ale•v,rps oet.Yy.nmdr.ya q��x ��De,..,a.��n rocsxm.aoom:o-E...->mi•..r UTILITY ONG ISLAND POWER AUTHORITY LIPA) Rev Description Date A INITIAL DESIGN 5/11/2024 AA UPDATED DESIGN 08/06/2024 A.2 I UPDATED DESIGN 9/9/2024 PROJECT# 9471 DATE DRAWN 9/9/2024 DRAWN BY ER SHEET# PV-L2 TITLE COMBINER SPEC Alik IRONRIDGE XR Rail° Family XR Railp Family The XR RaiP� Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Railu to match. Over their lifetime, solar panels experience countless _ THESE DRAWINGS ARE SUBJECT TO extreme weather events. Not just the worst storms in years COPYRIGHT PROTECTION BY US LAW. but the worst storms In 40 years. High winds Capable Of REPRODUCTION IN ANY FORM ISEXPRESSLY FORBIDDEN WITHOUT PRIOR ripping panels from a roof, and snowfalls weighing + WRITTEN APPROVAL FROM CURRENT enough t0 buckle a panel frame. — RENEWABLES ENGINEERING INC. XR Rails" are the structural backbone Current t� preventing these results.They resist uplift, XR10 XR100 XR1000 - - enewabies protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among Engineering and efficiently transfer loads into the rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle building structure.Their superior no snow.It achieves spans up to 6 feet, wind and snow Conditions.while also extreme climates and spans up to 12 CURRENT RENEWABLES while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. ENGINEERING INC. spanning capability requires fewer 1760 CHICAGO AVE SUITE roof attachments, reducing the ll 6'spanning capability 10'spanning capability 12 spanning capability J-13,RIVERSIDE CA 22507 number of roof penetrations Moderate load capability Heavy load capability Extreme bad capability PHONE: cRENG 05 1733 Clear&black anodized finish Clear&black anodized finish Clear anodized finish WWW CO and the amount Of -. Internal splices available Internal splices available Internal splices available CONTRACTOR INFO installation time. Rail Selection The table below was prepared in compliance with applicable engineering codes and standards." Values are CZSYS based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof 9 Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. ELEMENT ENERGY LLC. . — 7470 SOUND AVENUE,MATTITUCK, •. • �' LIMA NEW YORK,11952 PH:(631)779 7993 ® sicence-ME-5 689 com Licence-ME-52689 Force-Stabilizing Curve 90 (MASTER ELECTRICIAN) Licence-HI-67461 Sloped roots generate both vertical and lateral 120 Y (SUFFOLK HOME IMPROVEMENT) forces on mounting rails which can cause them to None bend and twist.The curved shape of XR Rails ' 140 is specialty designed to increase strength in both XR10 K I M & MAH LO N R U SSE LL directions while resisting the twisting.This unique feature ensures greater security during extreme 160 2045 LONG CREEK DR, weather and a longer system lifetime. 90 SOUTHOLD,NY 11971 PV SUMMARY 120 SYSTEM SIZE 20 (KWDC) STC 425 X 28 = 1.900 +•��' 140 ' PTC 398.1 % 28 = 1,147 160 SYSTEM SIZE(KWAC) 8960 Q240 90 MODULES 28 111NKO SOLAR KM42SN-54HL4-B 30 MICRO-INV.OTY 28 160 MICRO ENPHASE IQSMC-72-M-US INVERTER UPA Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 UTILITY ON)ISLAND POWER AUTHORITY XR Rails`are IronRidgel offers All XR RailsP are made of 6D00-series 40 compatible with a range of lift leg aluminum alloy,then protected with an 160 FlashFootl�and options for flat anodized finish.Anodizing prevents surface A other pitched roof roof mounting and structural corrosion.while also providing 60 160 Rev Description Date attachments. applications. a more attractive appearance. % i - 120 160 ^� A INITIAL DESIGN 511112024 AA UPDATED DESIGN 08/06/2024 --Table is meant to be a stmplifiec span chart rot conveying general rail capabilrfies.Use approved cer1nccatwn letters for actual design guidance. A.2 UPDATED DESIGN 9/9/2024 PROJECT# 9471 t J DATE DRAWN 9/9/2024 DRAWN BY ER SHEET# PV-7 3 TITLE RAIL SPEC Adaptive, Rafter-Friendly Installation AA IRONRIDGE QuickMounf The Respect Your Roof DeservesANA mlu . THESE DRAWINGS ARE SUBJECT TO When integrating with a home.solar attachments V COPYRIGHT PROTECTION R IS LAW 9 9 REPRODUCTION IN ANY FORM IS must be dependable for the lifetime Of the rooftop. - - =---- EXPRESSLY FORBIDDEN WITHOUT PRIOR Due to recent innovations.many asphalt Shingles _ WRITTEN APPROVAL FROM CURRENT � RENEWABLES ENGINEERING INC. have bonded courses.A mount that protects without • the need to pry shingles can really speed things up. Cllffe(it Halo UliraGnp (HUG`) is here to respect the roof. ��^wable Its Halo is acast-aluminum barrier that encases the — Ena-)eerinc UltraGrip. our industrial-grade.foam-and-mastic J seal.This allows HUG to accelerate the installation - - Still ll ' CURRENT RENEWABLES process and provide the utmost in waterproofing ••• ••• •,• ENGINEERING INC. P P P 9 •nly 2 •Structural Screws are needed to•eck 1760 CHICAGO AVE SUITE mount it. protection. Give your roof a HUG. J-13 RIVERSIDE CA 92507PHONE.(951)-405-1733 W W W.CRENG.CO CONTRACTORINFO Mulb-Tiered Waterproofing Trusted Strength & Less Hassle HUG'utilizescomponents t a mufti-tiereddrevstack of components to provide revoiufionary waterproofing protection The Halo cast- Structural capacities of HUG` were reviewed in _ armmr,m,ratsed-penn-eterfoundation many load directions. with racking rail running RdS the p base foam- seal co Ec SYSO Rustic seal combination that � cross-slope Or Up-Slope In relation t0 roof pitch. u water intrusion by adhering with the shingle surface. -- -- For further details. see the HUG certification ELEMENT ENERGY LLC. raGrip"is part letters for attaching t0 rafters and decking. 7470 SOUND AVENUE,MATTITUCK, C_nckMount NEW YORK,11952 ne. - -� PH:(631)779 7993 IronRidge designed the HUG, in combination services@e2sys.com f• Licence-ME-52689 with the RD Structural Screw to streamline UftraGrip`Seal Technologyt A installs.which means the following: (MASTER -HI-6 461 g� Licence-HI-67461 HUG UttraGnp utilizes a state-ot-the- - - (SUFFOLK HOME IMPROVEMENT) art seal design that uses a unique No prying shingles foam-and-mastic combination.The K I M & M A H LO N R U SS E L L foam-backed adnesive provides an No roof nail interference entirely new flashing system that 25-Year Warranty No pilot holes necessary 2045 LONG CREEK DR, conforms and adheres to every nook P ,c-.I ,a-a-''e.J and cranny of composition shingles. of impe r ng defects. No sealant(in most cases) SOUTHOLD, NY 11971 filling gaps and shingle step-downs t - No butyl shims needed (up t0 1/8 In height)- -_—__-- PV SUMMARY SYSTEM SIZE STC 425 X 28 =11.900 (KWDC) AttachmentPTC 3981 X 28 = t-147 SYSTEM SIZE g,960 �240 i Loading DesignRatings (KWAC) MODULES 28 11NKO SOLAR 1 KM425N-54HL4-B MICRO-INV.OTY 28 MICRO INVERTER EN PHASE IO6MC-72-M-US Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to JUTILITY [LONG ISLAND POWER AUTHORITY Mount HUG"to the roof rafters.the root HUG has been and certified for the UL 441 Section UL 2703 mechanical --duPAI <,L deck,or both with our custom-engineered tested and rated to compliance with i 27"Rain Test"and i and bonding _ RD(rafter-or-deck)Structural Screw.The RD Triple Rated d Certified Structural Screw anchors HUG to the roof support 1004 (ibs)of the International TAS 100(A) 95 requirements. See to Respect the Roof•' • - l Rev Description Date p �' � with an EPDM seating washer,completing uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual IA INITIAL DESIGN 5/1 112 0 24 UL 2703.441(27) the stack of waterproofing barriers See � Intertek TAS 100(A)-95 backside for more Installation information. Of lateral load. ASCE/SEI-7. ( Test"by Intertek. for more info. Al uaonreD DESIGN oe oszoza A.2 UPDATED DESIGN 9/9/2024 PROJECT# 9471 0 2D23 lronRidge.Inc,AJI rights reserved.Visit w—ir-patents.corn for patent infornation.Version 1.03 DATE DRAWN 9/9/2024 DRAWN BY ER SHEET# PV-7.4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd 28357 Industrial Blvd. R O N R I DG E Hayward.CA 94545 Hayward,CA 94545 1-800-227-9523 I R O N R I D G E 1-800-227-9523 IronRidge.com IronRidge.com Attn:Corey Geiger,COO, IronRidge Inc. Date:September 7'^.2021 The parameters and adjustments allowed in the span tables are defined as the following: THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. M IS Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5 1. TION IN ANY F WT EXPRESSLY FORBIDDEN HOUT PRIOR 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B for Risk Category II and applicable state&local WRITTEN APPROVAL FROM CURRENT p 9 ( 9 rY ) PP RENEWABLES ENGINEERING INC. This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System The county/city amendments to the IBC. No special wind topographic features are included and both topographic contents of the letter shall be read in its entirety before applying to any project design The Flush Mount System is a coefficient(Ka)and wind ground elevation factor(Ke)are taken as 1.0 Current proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails 3. Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig.7.2-1 and �eWa�E'$p applicable state&local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the - to Ineerin and secured to the rails with IronRidge mounting clamps The XR Rails are side mounted to a selected roof format of a Flat roof snow,it shall first be Converted to a ground snow following the local building code/ 9 9 attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables No special snow conditions are considered CURRENT RENEWABLES that is fastened to the underlying roof structure Assembly details of a typical Flush Mount Installation and its core including unbalanced.drifting.sliding,retention.or ponding snow No rain-on-snow surcharge load is ENGINEERING INC. components are shown in Exhibit EX-0015. considered The span tables do not apply to buildings which are intentionally kept below freezing,kept just 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 above freezing.or unheated. PHONE(951)-405-1733 WWW CRENG CO The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: CONTRACTOR INFO listed below,for the load conditions and configurations tabulated in the attached span tables. - (a)For ground snow no greater than 42psf: S,<_2 Og for Site Class A,B,C,&D • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf S,<_1 Og for Site Class A.B,C,&D. • 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf S,<_1.5g for Site Class A,B,C, &D . 2020 Building Code of New York State(BCNYS-2020, Published in November 2019) CZ w�0 • 2015 Aluminum Design Manual(ADM-2015) 5 Roof zones are defined by ASCE 7-16 Figure 30 3-2A to Figure 30.3-21 and are organized into three groups inI 1 u • Report SEAOC(Structural Engineer Association of California)PV2 2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCp).Roof zones Comprising each group along with each roof zone's size and location are depicted in Figures 2 and 3 below each span table ELEMENT ENERGY LLC. The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point.shall 7470 SOUND AVENUE.MATTITUCK, g P NEW YORK,11952 the respective loads and configurations listed,covering wind exposure categories B,C, &D,roof zones provided in be the lesser of the following two conditions.40%of the allowable span provided for the respective load PH:(631)779 7993 &configuration condition from the span tables,or 36 services@e2sys.com ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8`to 45`. The tabulated spans are applicable when the Licence-ME-52689 following conditions are met: 7 Allowable span length in the charts may be multiplied by a factor of 1 08 if the rails are continuous over (MASTER ELECTRICIAN) Licence-HI-67461 a minimum of three Spans. (SUFFOLK HOME IMPROVEMENT) 1 Span is the distance between two adjacent roof attachment points(measured at the center of the 8. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: attachment fastener) KIM & MAHLON RUSSELL a) XR Bonded Splice cannot be installed in the center 113 of interior spans,or the outer 2/3 of end spans. 2045 LONG CREEK DR, 2 Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system) Spans are Calculated b) BOSS Splice can be installed at any location within a span_ SOUTHOLD, NY 11971 based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If PV SUMMARY such conditions are encountered contact support@ironridge.COm. SYSTEM SIZE STC 425 X 28 =11.900 3 The underlying roof slope,measured between the roof surface and horizontal plane.is 80 to 45' (KWDC) PTC 3981 X 28 =11 147 4 The mean roof height,defined as the average of the roof eave height and the roof ridge height measured SYSTEM SIZE 8.960 9240 (K WAC) from grade,does not exceed 30 feet MODULES 28 JINKO SOLAR J KM425N-541-114-13 MICRO-INV.OTY 28 CR 5. A clearance from the underside of the array to the roof surface of 2'minimum shall be provided and the IN ENPHASE IosMcaz-M-us height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not UTILITY ONG ISLAND POWER AUTHORITY LI PA) exceed 10". 6. Module length and area shall not exceed the maximum values listed on the respective span tables. Rev Description Date A INITIAL DESIGN 5/11/2024 7, All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush At UPDATED DESIGN o8/06/2024 Mount Installation Manual and other applicable standards for the general roof construction practice. A 2 UPDATED DESIGN 9/9/2024 PROJECT# 9471 DATE DRAWN 9/9/2024 C 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-1 IV 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-2 DRAWN BY E R SHEET# PV-75 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward.CA 94545 Hayward,CA 94545 RON RI DGE fronRi ge.co 23 1 RON RI DGE lronRi ge.co 23 IronRidge.com IronRidge.com 10. Systems using CAMO module clamps shall be installed with the following guidance: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67-5 CAMO consideration of the structural adequacy of the chosen roof attachments. PV modules.or the underlying roof supporting THESE DRAWINGS ARE SUBJECT TO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater Such COPYRIGHT PROTECTION A scenarios are shown by asterisks in the applicable span tables members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the S LAW. REPRODUCTION IN ANY FORM IS S b) CAMO will function within a modules design load ratings Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CAMO meets the dimensional requirements shown in the figure below and that the module selected is RENEWABLES ENGINEERING INC suitable for the environmental conditions of a particular project. PxY_ N NE�V`O 2 O 21 0 JQ O 7 Sincerely. x °�r Current MoQIIeGQSS/Celts oln ?enewables 15:45: 16Engineering CURRENT RENEWABLES ���.n T9 02O —O OO t! ENGINEERING INC. �GFESS{O�t�' 1760 CHICAGO AVE SUITE _ J-13.RIVERSIDE CA 92507 h Orrte Cornpohbify. PHONE.(951)-405-1733 x=1.2-2.2 mm WWW CRENG CO Y-15-40 rrtm Gang Xuan, PE CONTRACTOR INFO Y - Senior Structural Engineer t z Figure 1 CAMO Module Frame Dimensional Requirements a 0 Span values for Exposed and Edge module conditions, as defined below, are included in the attached span EZ SYS5 tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; ELEMENT ENERGY LLC. (2)The span value determined by site wind speed and ground snow load.Additionally,irrespective of the lesser 7478 SOUND AVENUE,MATTITUCK, NEW YORK,11952 span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage PH:(631)779 7993 limitation detailed in note 9 of page 2 shall apply to the respective condition. services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI- 1. Exposed Module conditions: (SUFFOLK HOME IMPROVROV EMENT) A module is defined as Exposed(per Section 29 4 4 of ASCE 7-16)if the distance from any of its free KIM & MAHLON RUSSELL edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge,rake,or 2045 LONG CREEK DR, hip)is greater than 0 5h(h is ASCE defined building height)AND if the distance from its free edge to any SOUTHOLD, NY 11971 other adjacent array or panel is greater than 4 feet. PV SUMMARY SYSTEM SIZE STC 425 X 28 =11.900 The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed (KWDCI Modules. PTC 398.1 X 1 28 =11 147 SYSTEM SIZE g g60 9240 (K WAC) 2. Edge Module conditions: MODULES 28 1KM4 SOLAR OS454HL4-B MICRO-INV.QTY 28 MICRO ENPHASE IQ8MC-72-M-US A module is defined as an Edge Module when its distance from any side of the module to its facing INVERTER perimeter roof edge(such as eave,ridge,rake..or hip)is less than 2 times the height of the array(2h2) UTILITY ONAGISLAND POWER AUTHORITY LIP where h2 is measured from the roof surface to the top surface of the module. The allowable spans and Cantilever shall only be applied to the portion of rail directly under Edge Modules Rev Description Date Additionally, if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered A INITIAL DESIGN 5/11/2024 for this span adjustment. Al UPDATED DESIGN 08/06/2024 A.2 UPDATED DESIGN 9/92024 PROJECT# 9471 2021 Iron Rtlge.Inc. NY Flush Mount System Certification Letter-3 Cc�2021 IronRltlge.Inc. NY Flush Mount System Certification Letter-4 DATE DRAWN 9/9/2024 DRAWN BY ER SHEET# PV-7 6 TITLE CERTIFICATION ENPHASE CZ= V . IQBMC Microinverter Our newest IQ8 Series Microinverters are the industry's first microgrid-forming',software- Easy to install defined microinverters with split-phase power conversion capability to convert DC power to Lightweight and compact with plug- AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary and-play connectors application specific integrated circuit(ASIC),which enables the microinverter to operate in Power line communication(PLC) grid-tied or off-grid modes.This chip is built in advanced 55 nm technology with high-speed between components digital logic and has superfast response times to changing loads and grid events,alleviating constraints on battery sizing for home energy systems. Faster installation with simple two-wire cabling High productivity and reliability Produces power even when the grid is down' More than one million cumulative hours Part of the Enphase Energy System, I08 Series Microinverters redefine of testing IQ8 Series Microinverters integrate with reliability standards with more than one Class II double-insulated enclosure the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Optimized for the latest high-powered Enphase App monitoring and analysis testing,enabling an industry-leading PV modules software. limited warranty of up to 25 years. Microgrid-forming Complies with the latest advanced grid / support CERTIFIED Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed Configurable to support a wide range to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and of grid profiles integrated MC4 connectors. conforms with various regulations when Meets CA Rule 21(UL 1741-SA)and IEEE installed according to the manufacturer's 1547:2018(UL 1741-SB) instructions. Note: IQ8 Series Microinverters cannot be mixed together with previous generations of Enphase microinverters •Only when installed with IQ System Controller 2 meets UL 1741, (107 Series,IQ6 Series,and so on)in the same system. C 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,C.and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject to change. 108MC-MC4-DSH-00049-2.0-EN-US-2023-09-11 IQBMC Microinverter INPUT DATA(DC) UNITS I08MC-72-M-U3 Commonly used module pairings w 260-460 Module compatibility To meet compatibility,PV modules must be within the maximum input DC voltage and maximum module Ix listed below. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 25-45 Operating range V 18-58 Minimum/Maximum start voltage V 22/58 Max.input DC voltage V 60 Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max module IK A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit Peak output power VA 330 315 Max.continuous output power VA 320 310 Nominal grid voltage(L-U V 240,split-phase(L-L),180` 208,single-phase(L-0,120' Min./max.grid voltage' V 211-264 183-229 Max.continuous output current A 1.33 1.49 Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over three cycles Arms 2.70 Max.units per 20 A(L-L)branch circuit 3 12 10 Total harmonic distortion % <5 Overvoltage class AC port III AC port backfeed current mA 18 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging Peak efficiency % 97.38 97.23 CEC weighted efficiency % 97.00 96.50 Nighttime power consumption mw 28 25 MECHANICAL DATA UNITS Ambient temperature range -40'C to 65'C(-4O'F to 149'F) Relative humidity range 4%to 100%(condensing) DC connector type StBubli MC4 Dimensions(H•W•D}Weight 212 mm MY)•175 mm(6.9")•30.2 mm 0.2"}1.1 kg(2.43 Ibs) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure Environ.category;UV exposure rating NEMA Type 6;outdoor COMPLIANCE CA Rule 21(UL 1741-34 UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C221-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https.//enphase.com/installers/microlnverters/calculator. (2)Nominal voltage range can be extended beyond nominal if required by the utility. 108MC-MC4-DSH-00049-2.0-EN-US-2023-09-11 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. Q.TRON Bill M-G2+ SERIES ocells 405-430 Wp 1108 Cells 22.0% Maximum Module Efficiency MODEL QXRON BLK M-G2+ G.HNTUM High performance Ocells N-type NF-0 solar cells Q.ANTUM NEO Technology with optimized module layout boosts module efficiency up to 22.0%. 25 A reliable investment —- Inclusive 25-year product warranty and 25-year linear Warranty performance warranty'. .0-ftft; Enduring high performance Long-term yield security with Anti LeTID Technology,Anti PID coNls Technology2,Hot-Spot Protect. Extreme weather rating High-tech aluminium alloy frame,certified for high snow(8100 Pa)and wind loads(3600 Pa). Innovative all-weather technology CD Optimal yields,whatever the weather with excellent low-light and temperature behaviour. n The most thorough testing programme in the industry Ocells is the first solar module manufacturer to pass the most comprehensive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. 'See data sheet on rear for further information. 'APT test conditions according to IEC/TS 628041:2015,method A(-1500 V,96 h) The ideal solution for. /� Rooftop arrays on 7033 d o �` I n I residential buildings USA QXRON BLK M-G2+ SERIES all Mechanical Specification ne W r.s•Im,..l Format 678 in x 44.6 in•1.18 In(including frame) 30.•p°Dn^^-1 I (1722 mm x 1134 mm x 30 mm) Weight 46.71bs(21.2kg) 1 Front Cover 0.13 in.(3.2 mm)thermally pre-stressed glass '0.1 ' losoma ""' with anti-reflection technology Back Cover Composite film ..elrwaq Frame Black anodised aluminium Cell 6 x 18 monocrystalline OANTUM NEO solar half cells t'0e� ea.mao"+q Junction box 2.09-3.98in x 1.26-2.36inx 0.59-0.71in ..5..-,.°. (53-101mm x 32-60mm x 15-18mm),Protection class IP67,with bypass diodes +paT"� a..i Cable 4 mm'Solar cable;(+)2!68.9 in(1750mm),(-)a68.9 in(1750mm) L -A oba,�,alu Connector Sttiubli MC4;IP68 all Electrical Characteristics POWER CLASS 405 MO 40 420 425 430 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STO(POWER TOLERANCE+5 W/-0 W) Power at MPP' PM„ [W] 405 410 415 420 425 430 Short Circuit Current' Isc [A] 13.33 13.41 13.49 13.58 13.66 13.74 E E Open Circuit Voltage' Va M 37.91 38.19 38.47 38.75 39.03 39.32 S Current at MPP I.W [A] 12.69 12.76 12.83 12.91 12.98 13.05 f Voltage at MPP Vw„ M 31.93 32.13 32.34 32.54 32.74 32.94 Efficiency' r) [%] 220.7 z21.0 2213 221.5 >>-21.8 222.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP Pi,, [VI/] 306.1 309.9 313.7 317.5 321.2 325.0 E Short Circuit Current IS, [A] 10.74 10.81 10.87 10.94 11.00 11.07 E Open Circuit Voltage Voc M 35.96 36.23 36.50 36.77 3704 37.31 c 2 Current at MPP Iw [A] 9.98 10.04 10.10 10.15 10.21 10.27 Voltage at MPP Vrl„ M 30.66 30.87 31.07 31.26 31.46 31.65 'Measurement tolerances PI,,,t3%;Ix;Voc t5%at STC:1000 W/m2,25 t2°C,AM 1.5 according to IEC 60904-3.2800 W/m2.NMOT,spectrum AM 1.5 OCOUS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE m ro ws � At least 98.5%oi nominal power � our during first year Thereafter max 2 as ------ ------ 0.33%degradation per year.At w I r a ! least 95.53%of nominal power y 1m --+-----y----- z ao up to 10 years.At least 90.511%of w zo nominal power up to 25 years. g w y_ a _ All data within measurement °0 w0 a5 __________ w tolerances.Full warranties in -n accordance with the warranty g o m terms of the Qcells sales w au o as w n ao a organisation of your respective 200 YEARS country. IRRADIANCE(W/m': O 'Standard turns of guarantee for Ne 5 W companies with the Typical module p-rmance under low irradiance condiuorrs in highest production®pacay n 2021(February 2021) comparaon to STC oo,4,tions(25'C,1000 W/m). Y TEMPERATURE COEFFICIENTS S Temperature Coefficient of Ix a [%/K] +0.04 Temperature Coefficient of Voc p i%/K] -0.24 109t5.4 Temperature Coefficient of Pw„ y [%/K] -0-30 Nominal Module Operating Temperature NMOT rFi (43t3°C) all Properties for System Design & Maximum System Voltage Vs s M 1000(IEC)/1000(UL) PV module classification Class II Maximum Series Fuse Rating [A DC] 25 Fire Rating based on ANSI/UL 61730 C/TYPE 2 0 Max.Design Load,Push/PU113 [Ibs/ftq 113(5400Pa)/50(2400Pa) Permitted Module Temperature -40°F up to+185°F g Max.Test Load,Push/PuIP [lbs/ft2] 169(8100Pa)/75(3600Pa) on Continuous Duty (-40-C up to+85°C) 3 See Installation Manual ■Qualifications and Certificates UL61730-18 UL61730-2,CE-compllant, Quality Controlled PV-Tl1V Rheinland, IEC 6 Patent o.IEC 3,2 5:solar (/ r♦ ® IR U.S.Patent No.9,893,215(solar cells). 0-Nus ` \ � e 'Contact your Ocells Sales Representative for details regarding the module's eligibility to be Buy American Act(BAA)compliant .-irl�a�a Qcells pursues minimizing paper output in consideration of the global environment. Nate:Irotallation instructions must be followed.Contact our techniwi service for further Information on approved Installation of this product Qcel I S Hanwha Q CELLS Americ a I nc.400 Space-Center Drive,Suite MO.Irvine,CA 92618,USA I TEL M 949 748 59 961 EMAIL hgc-InquW^cells.com I WEB v w gcers.com