Loading...
HomeMy WebLinkAbout50699-Z O�ogulFot�-coG. Town of Southold 10/4/2024 P.O.Box 1179 o o _ 53095 Main Rd yfjal o�., Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45620 Date: 10/4/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 400 Legion Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 142.-2-8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/5/2024 pursuant to which Building Permit No. 50699 dated 5/17/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Constantin-Guild,Jennifer&Joseph of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50699 9/9/2024 PLUMBERS CERTIFICATION DATED A hor z d S gnature �SUFFotK�o TOWN OF SOUTHOLD BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE oy • V SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50699 Date: 5/17/2024 Permission is hereby granted to: Constantin-Guild, Jennifer 400 Legion Ave Mattituck, NY 11952 To: install roof mounted solar panels to existing single-family dwelling as applied for. At premises.located at: 400 Legion Ave, Mattituck SCTM #473889 Sec/Block/Lot# 142.-2-8 Pursuant to application dated 4/5/2024 and approved by the Building Inspector. To expire on 11/1612025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector O��OF SOUr�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �. �Q sean.devlina-town.southold.nv.us Southold,NY 1 1 97 1-0959 Oly�0UM�1,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jennifer Constantin- Guild Address: 400 Legion Ave - city:Mattituck st: NY zip: 11952 Building Permit#: 50699&50700 Section: 142 Block: 2 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement House X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12.75kW Roof Mounted PV Solar Energy System w/ (30):JKM425N-54HL4-B Modules, (2) Enphase IQ Combiners One Has(2) 220& (1) 215, Other Has(1) 220 & (1) 215, 40A AC Disconnect, Unfused Disconnect Solar On House &Acc. Garage Inspector Signature: d Date: September 9, 2024 S.Devlin-Cert Electrical Compliance Form Copy OF SO(/1,�°�o * # TOWN OF SOUTHOLD BUILDING -DEPT. cou ,N 631-765-1802 /� ' INSPECTION ©6aj [ -] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/ UL-Ke"10�NG [ ] FRAMING /STRAPPING [ FINALsai w�tXX,.tn� [ . ] FIREPLACE & CHIMNEY [ ] FIRE"SAFE INSPECTION [ "]" FIRE RESISTANT,CONSTRUCTION [ j FIRE RESISTANT PENETRATION [ "] ELECTRICAL (ROUGH) [ ] .ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: t DATE -INSPECTOR OF 50UTyolo �V (p 1 C6 9 Q TOWN OF SOUTHOLD BUILDING DEPT. IOU�m�a� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] .FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] 'FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE.RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) _ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:6,Ls. ' P1 C>. /� _ �t &nil -� &, Gr ( P � DATE ct INSPECTOR i4.:_ EC� EQ �IE Current � � Rene able OCT - 7 2024 Engineering Building Depertment rown 0,1 0 ratiac9t9 Town of Southold September 12, 2024 Subject: Post Installation Approval Letter Job Name: Joe Constantin-Guild Residence Project Address: 400 Legion Ave, Mattituck, NY 11720 To Town of Southold: I have reviewed the solar energy system installation in the subject topic on 06/13/2024.The units have been installed on in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, SEI/ASCE 7-16, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property, and public welfare. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. �Po�Of NEW yo Sincerely, ��oO�RT A. Professional Engineer Current Renewables Engineering info@currentrenewablesen FO 106793 gcom SSIONP� Exp:9/30/2025 STAMPED 9/12/2024 1760 Chicago_Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 Page 1 of 2 03/25/2024 Current Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Joe Constantin-Guild Residence Project Address: 400 Legion Avenue, Mattituck, NY, 11952 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, ASCE 7-16 Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 OF NEW Y Current Renewables Engineering Inc. Professional Engineer w info@currentrenewableseng.com y 106793 F �P Signed on:03/25/2024 1760 Chicaqo Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewablesenq.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 21 degrees and has a max beam span of 15.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 30 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x4 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 23 degrees and has a max beam span of 8.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicaqo Ave Ste J13, Riverside, CA 92507 (951)405-1733 info@currentrenewablesenq.com FIELD INSPECTION REPORT DATE COMMENTS �i ro FOUNDATION(IST) H ------------------------------------ Q C FOUNDATION (2ND) � z 0 ROUGH FRAMING& C, y PLUMBING 7 cp INSULATION PER N.Y. H STATE ENERGY CODE 1�1 Q ` FINAL ADDITIONAL COMMENTS S00 Z m G` Y y q� O (Jl z x y x C Cr7 ro i TOWN OF SOUTH OLD LD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. ®. Box 1179 Southold NY 1 1 97 1-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https•//wwtiv.southoldtow ny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only l� �';��•<:+�i� �,' ._.., � � '� PERMIT NO. Building Inspector: APR - 5 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. There the Applicant is not the owner,an is a�7.17111* 1"(71 DR"' 'L' IF Owner's Authorization form(Page 2)shall be completed, T �'P Date: /aA OWNER(S)OF PROPERTY: Name-1. 0 h C UY�S-t it) -C Ul/ TICTM#1000- l l�f-a , 00 ` 0a. 00 - c�c��. a9 o Project Address: G�-�� �e 6,Vr--) tiles &-+ t'� ,C . 1^ j 5 Phone#: �3 I.. � � 2 Qy' ) Email: $�� ir ,✓Nav�l� �S<CO3 Mailing Address: d-eq)"07 /a � M"I-i_1 ,,CIQ AJ. 1 ' 5� CONTACT PlERSOM c/l Z v` , l Name: Lo Mailing Address: -7410 SvLod avy', Ma-444� e, V. M5;�, Phone#: (03 � 3 9 9 �-7 0 q B Email: ll�S DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRAC rOR INFORMATION: Name: Mailing Address: 14q6 .S®"d O vY-) MA4 �vcr 0167 Phone#: 63 , 3Q '-� D Email: P�ira4sQ, ca's cS ' Corn DESCAJPT1ON OF PROPOSE®CONSTRU&80N ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated roject: then_ So)&C Pv s,a,�.�-,� I a k vy ous�- Will the lot be re-graded? ❑YesANo Will excess fill be removed from premises? ❑Yes'�00 t 1 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covena is and restrictions with respect to this property? ❑Yes C IF YES, PROVIDE A COPY. heck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the.Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,county,New York and'other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law: Application Submitted By(print name): �a y-r-�j�� � I'��p-�u authorized Agent ❑Owner Signature of Applicant: Date: LOUI OME STATE OF NEW YORK) Notary Public,State of New York SS: No.01 R06314813 rr Qualified in Suffolk County n �, COU NTY OF VI t �.� L ) Commission Expires November 17,20 L�17�IZI l �' 0 PI 1 �z� ��+ �� being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the oK)+Y-K&d, (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowl bb � Oelief• and gMEO� that the work will be performed in the manner set forth in the application file therewith Notary Public,State of Newyork Quallf ed in Suffolk County S Sworn before me this Commission Expires November 17,2q,2 day of 14N 20 ry Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, P)'l ConS4i rl--�e) `C�ti I Id residing at 4C O L! )"orl Q 1 LL7Yr(ti�/�.e> M&A+L" , N L It a5Z do hereby authorize EL&1L�&,L EY)L, j L.(--C>Al to apply on my behalf to the Town of Southold Building Department for approval as described herein. H Owner's Signature Date r yrr �V rll Notary LOUIS J ROMEO V '350, 14 60�� /�� � Nota Public,State of New York No.01R06314813 Print Owner's Name Qualified in Suffolk County Commission Expires November 17,20 � / 200 2 BUILDING DEPARTMENT- Electrical Inspector 49. TOWN of SOUTHOLD v� Town Hall Annex - 54375 Main Road - PO Box 1179 18 • Southold, New York 11971-0959 '�,�j p� Telephone (631) 765-1802 - FAX (631) 765-9502 roperr�southoldtownny.gov - sea nd��southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: e j eM CA4 Electrician's Name-.J0 rrw_., License No.: �, �� - �� Elec. email: P�C'rn i -k5 L Ca S �.Sb Cori Elec. Phone No: ;-)ojc13 L9I request an email copy of Certificate of Compliance Elec. Address.: � ,i-7 o cso vA d. ave, -, . Imo.. JKJ JOB SITE INFORMATION (All Information Required) Name: .J U cam, t�Sn - C Address: 2 cep ,� 45iSZ- Cross Street: M kJ n fQ _ Phone No.: (03 1 .51�Q a 77 O L Bldg.Permit #: SDloq email: pr oil- Tax Map District: 1000 Section: H Block: 0 3-- Lot: (; (V ` BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?-. ❑ YES ® NO ❑Rough In ❑ Final Do you need a Temp Certificate?-. ❑ YES ® NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# []New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? Y' N Additional Information:- T_nS+a II - - [L"h r-c o+ ,•n o,,�,�+(�, �;��a� 1�✓ PAYMENT DUE WITH APPLICATION PERMIT# Address: f " Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments r. A4 R CERTIFICATE OF LIABILITY INSURANCE DATEIMM7/1fDWYy 023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: K the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCERCONTACT ROBERT S.FEDE INSURANCE AGENCY NAME: PHONE pAX 23 GREEN STREET,SUITE 102 E-MAIL No EA: Ak Ne: - HUNTINOTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSU AFFORDING COVERAGE NAIC 0 �A:ATLANTIC CASUALTY INS.CO. 524210 INSURED b IA[I:INSURANCE FUND 523930 Element Energy LLC INSURERB' INSURER DBA ELEMENT ENERGY SYSTEMSc 7470 SOUND AVENUE MATTITUCK,NY 11952 04SURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE °Ovim POLICY NUMBER IF EFr �OLFCY EXP LIMITS COMMERCIAL GENERAL LIABILITY L1460036873 AX X 7/1412023 7/14I2024 EACH OCCURRENCE s 3,000,000 CLAIMS•MAOE IX-1OCCUR PREMISES Eaawrrence $ 100,000 �IA3ss2ose MED EXP{ cm Pusorr) s 5000 rG.FIRILAGGREGATE Contractual Lia 7l1912022 7I19/2Q24 PERSONAL a a0v INJURY s 3000000 LIMITAPPLIES PER GENERAL AGGREGATE 3 3.000,000 PRO- CY JECT F1 LOCPRODUCTS-COIUPlOPAGG $ER: s AUTOMOBILEUAWAY 0 f SI1GLELIMIT $ ANY AUTO BODILY INJURY(Par peraorl) $ AUTOS OWNED SCUTOSHEDULED BODILY INJURY(Per S HIRED ONLY NON-OWNED AUTOS ONLY AUTOS ONLY arrJdenh YY PROPERTY DAMAGE $ $ U MBRELLA OCCUR EACH OCCURRENCE $ S LU16H CLAIMS-MADE AGGREGATE $ RETENTION% $ WORKERSCGMPENSATIDN 124494445 PER ER AND ROPRIEERS'LIRTNERIABLITy Y1N 7/1312023 7113/2024 ANY PRCPRIETORlPARTNERIF�(ECUTA(E B OFRCERMMENI ER EXCLUDED? ED NIA E.L EACH ACCIDENT $ 1 OOt}O00 If ya,desu in Mpg wd EL DISEASE-EA EMPLOYE $ If yea,desuibe under DESCRIPTION OF OPERArONS below El DISEASE-POL{CY LIMB $ NY State DBL DBL567527 1/01/2023 12/3112024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS 7 VEHICLES OCORD 1DI,AOdttlonal Remarks SchedWe,msy ba attsehed B elere apaCe is reqWred) CERTIFICATE HOLDER IS ADDITIONAL INSURED Cerrttiificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis Including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORMED REPRESENTATIVE ROh, r S. Fede, O 1988-2015 ACORD CORPORATION. All rights reserved. ernlan�c»nearni� Tao A'-non.�...,, ..,a r .,, ,. ..,:a. . ,. _.o. „r Arncn NYSIF New York State Imurance Fund PO Box 66699,Albany,NY 122i16 nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) A A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 D HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07113/2023 TO 07/1312024 17)11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLiCYHOLDEITS REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS-REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:f/WWYII.NYSIF.COMICERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTED OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND T,�Y t/ DIRECTOR,INSURANCE FUND UNDERWRITING Y px workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND RAID FAMILY LEAVE BENEFITS LAW PART i.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that came 1a.Legal Name 8 Address of Insured(use street address only) 1 h.Business Telephone Number of insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work Location,of Insured(onlyregWred ifcoverage is specifically limited to or Social Security Number certain locations in New York State,be.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"1a' SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides the following benefits: ® A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. S. Policy covers. ® A.All of fhe employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or ctasses of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 BY W41,ht (Signature of insurance carrier's aud,orized representative or NYS Licensed insurance Ageot of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: ff Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. tf Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. h must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 6200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4e,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By lSignature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance porcies and NYS licensed insurance agents of fhose insurance carriers are authorized to issue Form OB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12 21) 11I ��rllIII�II�IIIII�IIiIIIlIIII���1 CZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE, MATTITUCK, NEW YORK, 11952 Date: 9/11/2024 Customer Name: JOE CONSTANTIN-GUILD Project Address: 400 LEGION AVE, MATTITUCK, NY 11952 REV-5 Outlined below are the list of rejections received from the plan checking department. Each revision will be marked in red in this letter and will also have red revision clouds on the permit packet/plan set. If you have any questions, please reach out. - Enphase IQ combiner 5 has been added in planset instead 3. -Notation of existing wire run through conduit mentioned. - Interconnection changed to breaker. -Removed fused disconnect and added one disconnect for branch 2&3. -Reflected on site plan as well. . o APPROVED AS NOTED Aq DA •-5 B.P.# Q FEE J� BY: - a�, NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQt l!c'F--D FOR POURED CONCRE I'-- 2. ROUGH-FRAMING&(LU;w 3t),,,3 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW.YORK STATE &TOWN CODES AS REQUIRED AND CONDITIO OF SOUTHOLD TOWN SOUTHOLD T PLANNING BOARD SOUTHO OWN TRUSTEES TEES . EC UTHOLD HPC CHO OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED Page 1 of 2 03/25/2024 Current Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Joe Constantin-Guild Residence Project Address: 400 Legion Avenue, Mattituck, NY, 11952 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, ASCE 7-16 Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 of NEW,,, A. Z4 ;4,:- Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com ti MIA 106793 F NP Signed on:03/25/2024 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 SUmmaries: Check 1: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 21 degrees and has a max beam span of 15.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 30 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x4 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 23 degrees and has a max beam span of 8.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com ROOF MOUNT SOLAR PERMIT PACKAGE CODE INFORMATION THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC Q NEW y POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: ��PO�Rt A J 0 E CO N STA NT I N-GUILD 2020 NEW YORK BUILDING CODE-BUILDING 2020 NEW YORK BUILDING CODE-RESIDENTIAL 12.000 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-EXISTING BUILDINGCkf r 6. i �, W 2020 NEW YORK BUILDING CODE-PLUMBING 400 LEGION AVE MATTITUCK NY 11952 2020 NEWYORK BUILDING 2020NEWYORKBUILDINGCODE-ENERGYICONSERVATION JCAL �pAROF679oNP\��c� ESSI 2020 NEW YORK BUILDING CODE-FUEL GAS /2025 2020 NEW YORK BUILDING CODE-ACCESSIBILITY ExpED 0 2020 NEW YORK FIRE PREVENTION CODE STAMPED 03/29/2024/29 BUILDING INFORMATION 2017 NEW YORK NATIONAL ELECTRICAL CODE THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 2 STORY HOUSE SINGLE FAMILY RESIDENCE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U AHJ :TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC ROOF:COMP SHINGLE APN:1000142000200000000 PV SYSTEM SUMMARY: Current SYSTEM SIZE(DC) STC:400 x 30=12.000KW DC Renewables PTC: 376.70 x 30= 11.3010KW DC Engineering SYSTEM SIZE(AC) 8.700KW AC @ 240V CURRENT RENEWABLES ENGINEERING INC. MODULES (30)CANADIAN SOLAR:CS6R-400MS-HL 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW CRENG CO MICRO-INVERTERS ENPHASE: IQ8PLUS-72-2-US AERIAL VIEW VICINITY VIEW CONTRACTORINFO MICRO-INVERTERS CITY 30 TILT 21°, 30°,30°,23°,23° ` AZIMUTH 132°,222°,42°,222°,42° Eg ® n ROOF COMP SHINGLE RAFTER/TRUSS SIZE 2"X10"/2"X8"RAFTER @ 16"O.C./2X4 RAFTER @ 24"O.C. RAFTER @ 24"O.C. Ez SYS9 ATTACHMENT TYPE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP WITH IRONRIDGE XR-100 , ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, EXISTING 200 AMPS MSP WITH 200 AMPS MAIN P' NEW YORK,11952 MAIN SERVICE PANEL BREAKER ON TOP FED PH:(631)779 7993 services@e2sys.com INTERCONNECTION LOAD SIDE TAP Licence-ME-52689 (MASTER ELECTRICIAN) OCPD RATING 50 AMPS Licence-HI-67461 `- (SUFFOLK HOME IMPROVEMENT) UTILITY PSEGLI Solar Individual GENERAL NOTES: Permit Package 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION ' 2 THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES SHEET INDEX JOECONSTANTIN-GUILD 3, PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 12.000KW Grid Tied 6, ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL 400 LEGION AVE, GROUNDING ELECTRODE PV-3.0 STRUCTURAL MATTITUCK,NY 11952 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" PV-4.0 ELECTRICAL 3LD Rev I Description I Date 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS PV-J.O ELECTRICAL SLID INITIAL DESIGN 3232D2a 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" 13, PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM At UPDATED DESIGN 3272024 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM Az I UPDATED DESIGN 3/30/2024 COMPLIES WITH 690.35. PV-7.0 SIGNAGE OPPORTUNITY I IOE CONSTANTIN-GUILD 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PV-7.1 PLACARD PROJEGTtt NA 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 17 ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.0 MICROI NVERTER CHART DATE DRAWN 3/30/2024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY E.R 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/81,ABOVE ROOF SURFACE. PV-9.0 SAFETY PLAN SHEET# Pv-,o 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE,TYPE NM CABLE PV-10.0 SAFETY PLAN ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0+ SPEC. SHEETS COVER PAGE 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: R32 NOT L.1 PATHWAYS: LEGEND NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SEPARATE ROOF PLANES. FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON PROPERTY LINE ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER 0 DRIVEWAY SIDE OF THE ROOF. I FENCE 186' FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM 361NCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE - --- ---- ---- --------------------------- — MAIN SERVICE PANEL S I SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS SUB PANEL I �• ':'� 18-10 I y O ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS �. DRIVEWAY , ��`O 106793 WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR r I AC DISCONNECT p�0 NPR MECHANICAL EQUIPMENT. . _ +,` FE SS1� CV :• '+•'•��'�' r /2025 R324.6.2 SETBACK AT RIDGE: L1J +�•'.•'•`'' �' 81'-11 C❑ COMBINER Exp: D 03/29 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 STAMPED �3/29/2U24 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN Q . 52r-9�r 19 AN 16 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO 1 � HORIZONTAL RIDGE. � i COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 O REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR 36 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A , WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. , RENEWABLES ENGINEERING INC. V � 23'-7" � ROOF OBSTRUCTIONS R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS UJI ` AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 44;7��__ _ ROOF ACCESS POINT Current RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE \ PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. / 149'-1 0" Re-- A -PATHWAY ON STREET FENCE/GATE Engineering OR DRIVEWAY SIDE OF ROOF PROPERTY LINE B -FIRE ACCESS POINT CURRENTRENEWABLES ENGINEERING INC. 36"ACCESS PATHWAYS WEE� PHONE E (951)O AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO 18"ACCESS PATHWAYS M CONTRACTOR INFO NOTES: ENLARGE VIEW 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND MEASUREMENTS. (N)COMBINER a M 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED INTO THE 2017 NEC AND UL (N)AC DISCONNECT EZSYS! STANDARD 1741. 3. EXISTING ROOF VENT SHOULD NOT BE (E) UTILITY METER ELEMENT ENERGY LLC. COVERED. 7470 SOUND AVENUE,MATTITUCK, (E)MAIN NEW YORK,11952 7993 NOTE: SERVICE PANEL PH:(631)779 services@e2sys.cos.com REVENUE GRADE KWH PRODUCTION METER Licence-ME-52689 CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 STANDARDS. c AC um ROOF OBSTRUCTION (M LSTeEtReELECT6RICIAN) (SUFFOLK HOME IMPROVEMENT) sue 1..1..1 FIT] A (E)SUB PANEL Solar Individual Q Permit Package z JOE CONSTANTIN-GUILD _0 (N)AC DISCONNECT V 12.000KW Grid Tied W Photovoltaic System J - 400 LEGION AVE, 1z MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 At UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 3/30/2024 OPPORTUNITY JOE CONSTANTIN-GUILD 71 PROJECT# NA DATE DRAWN 313012024 SITE PLA�1 -0' 36"ROOF ACCESS POINT ROOF LINE DRAWN BY ER &�SCALE- 36" ROOF ACCESS POINT SHEET# iiiia-20 TITLE 1/32" = SITE PLAN ARRAY AREA LEGEND EAVE TO ROOF ROOF TOTAL _ #OF RIDGE ARRAY AREA AREA AREA Of NEW,,,, ROOF ROOF TYPE AZIMUTH AREA MODULES DIMENSION (Sq.Ft.) COVERED BY COVERED BY PEE w jO (Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) � #t COMP SHINGLE 132 UM UTILITY METER � oO�R`A. lq 9 14.58 189.18 2111 8.96 Q #2 COMP SHINGLE 222 6 13.50 126.12 2111 5.97 SP MAIN SERVICE PANEL �!",, #3 COMP SHINGLE 42 1 5 13.50 105.10 2111 1 4.98 1 29.87 r rr #4 COMP SHINGLE 222 5 8.50 105.10 2111 4.98 #5 COMP SHINGLE 42 5 8.50 105.10 2111 4.98 UB SUB PANEL yf 106793 �c AC DISCONNECT p'�OFESSIONP� (N)#30 CANADIAN SOLAR: CS6R-400MS-HL C COMBINER Exp:9/30/2025 STAMPED 03/29/2024 JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS ROOF#5 MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N)COMBINER ROOF OBSTRUCTIONS (N)AC DISCONNECT Current (E) UTILITY METER Renewabies (E)MAIN SERVICE PANEL Engineering CURRENT RENEWABLES w ROOF#3 ENGINEERING INC. c I AC CUM 1760 CHICAGO AVE SUITE Q SU6 ROOF#4 J-13.RIVERSIDE CA 92507 PHONE.(951)-4051733 WWW.CRENG.CO z AC (E)SUB PANEL CONTRACTOR INFO L1J (N)AC DISCONNECT mum J STRUCTURAL NOTES :NOTES : EzSYS9 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE Em COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE 7470SO NN DAVENUE,MATTITUCK, PROPOSED PV INSTALLATION ONLY. NEW YORK,11952 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. PH.(6s1) services@e2s2sys.cos.com 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS Licence-ME-52689 MUST FOLLOW MANUFACTURER GUIDELINES AND (MA Licence- 67461 I ffl1I I REQUIREMENTS. (SUFFOLK HOME IMPROVEMENT) 3' 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. Solar Individual 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR Permit Package ROOF#1 ROOF#2 INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY JOE CONSTANTIN-GUILD INCONSISTENCY BETWEEN SITE VERIFICATION AND 12.000KW Grid Tied FOLLOWING: - ROOF 1:2x10 RAFTERS @ 16" OC SPACING WITH MAX Photovoltaic System UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. 400 LEGION AVE, - ROOF 2&3: 2x8 RAFTERS @ 16" OC SPACING WITH MAX MATTITUCK,NY 11952 UNSUPPORTED SPAN EQUAL OR LESS THAN 14 FT. Rev Dept— Date - ROOF 4&5: 2x4 RAFTERS @ 24" OC SPACING WITH MAX A INITIAL DESIGN 3/2 312 0 2 4 UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. Al UPDATED DESIGN 3/272024 A2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN N302024 2 ROOF PLAN DRAWN BY ERtp SHEET# PV-2 1 TITLE SCALE: 3/32" = V-0" ROOF PLAN ROOF ROOF ROOFING FRAMING FRAMING OC PENETRATION MAX ATTACHMENT TYPE PENETRATION MAX p NEW NO TILT TYPE TYPE SIZE SPACING PATTERN SPACING OVERHANG h�P�O 9LI A lgy0;� * ROOF 1 21 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x10" 16" FULLY STAGGERED 64" A ROOF 2 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16" FULLY STAGGERED 64" ROOF 3 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16" FULLY STAGGERED 64" 24" OA,p10 6793NP�`��� ESSI ROOF 4 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" Exp:9/30/2025 ROOF 5 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" STAMPED 03/29/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renew., CANADIAN SOLAR:CS6R-400MS-HL Engineering CURRENT RENEWABLES IRONRIDGE XR-100 ENGINEERING INC. 1760 CHICAGO AVE SUITE TABLE PENETRATION PHONE E(951IDE-1733CA 7 PHONE(951Id0&1733 GUIDE FOR INSTALL WWWG COOT CONTRACTORINFO 4• (E)COMP SHINGLE TWO OR MORE ROWS OF PANELS � mum 2.5 MIN.EMBED. QUICKMOUNT UICKMOUNT HALO ULTRA GRIP I I I I I I I I I I I I I I I I I I I C2SYS8 I I I I I I I I I I I I I I I I I I I I ELEMENT ENERGY LLC. #14 X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING 7470 SOUND AVENUE,MATTITUCK, RAFTER NEW YORK,11952 Tz PH:(631)779 7993 Licence-ME52689 (E) 2"X10"/2"X8" RAFTER @ 16"O.C. I I I I I I I I I I I I I I (MASTER ELECT7 ELECTRICIAN) ENLARGED VIEW 2X4 RAFTER @ 24"O.C. U Licence- 66 LK HOME IMPROVEMENT) STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE XR-100 Permit Package IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ONE ROW OF PANELS JOE CONSTANTIN-GUILD CANADIAN SOLAR: CS6R-400MS-HL 71 12.000KW Grid Tied SEE ENLARGED VIEW I I I I I I I ( I I I I I Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 (E) 2"X10"/2"X8" RAFTER @ 16"O.C. 2X4 RAFTER @ 24" O.C. FULLY STAGGERED STACKED/STAGGERED Rev Description Date A INITIAL DESIGN 3/232024 A UPDATED DESIGN 3272024 A UPDATED DESIGN 3/302024 ATTACHMENTDETAILS (E)COMP SHINGLE OPPORTUNITY IOE CONSTANTINI UILD PROJECTO NA DATE DRAWN 3/302024 DRAWN BY E.R SHEET It PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING BACKFEED FUSE SIZING MAX'CONTINUOUS OUTPUT 1.21A @ 240V MAX. CONTINUOUS OUTPUT 1.21A @ 240V ��oF NEW MANjq .Q 24.20 X 1.25 = 30.25AMPS 40A FUSES-OK (N)60A FUSED AC 12.10 X 1.25 = 15.13AMPS 20A FUSES-OK DISCONNECT SQUARE D D322NRB 44/ WITH 20 A FUSES, AWG#12,SKU'.Q-12-RAW-300,THHN KNIFEBLADE, n W (10)IQ8PLUS-72-2-US 1-#8 AM LOCKABLE ,EGC THAN-2 m D9912$ _2 - IN 3/4.OR LARGER PVC CONDUIT ,NEMA 3R, 2 MICROINVERTERS ILL LISTED BRANCH-1 4I� �OA CTRIGP`' 10 CANADIAN N7 ___ ____ ___-- Ofb __________ ___ -------- ,r� SS101" SOLAR:CS6R40OMS-HL � I 3-#6 AWG,THWN-2 I STAMPED 03/29/2024 1-#8 EGC,THWN-2 (E)10DA RATED IN 3l4"OR LARGER PVC MAIN BREAKER CONDUIT (END FED) I THESE DRAWINGS ARE SUBJECT TO (E)1 RATED SUB PANEL I COPYRIGHT PROTECTION BY US LAW. SUB 1 PH.120240V 60HZ I REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT (N)ENPHASE I MANS ER VICE PANED (E)UTILITY RENEWABLES ENGINEERING INC METER COMBINER BOX MODEL m i 1PH,120240VWHZ NO#X24Q-AM1-240-4 (E)200A/2P MAIN ® Current CELL WIRELESS ; I (TOPTOP FED) {� c MODEM COMMS I Rei ewa'moL7,les - IQGATEWAY r-J Engineering r\ (10)IQ8PLUS-72-2-US - m (N)LOAD MICROINVERTERS (N)15: (N)60A FUSED SIDE TAP CURRENT RENEWABLES r AC DISCONNECT ENGINEERING INC. BRANCH-2 I I SQUARE D D322NRBCHICAG 10 CANADIAN N I I WITH 40A FUSES: 1 760 RVERSI AVE SUITE I SOLAR:CSGR-400MS-HL ,• I KNIFEBLADE, �7 PHONE 95SI-0O5-1733 LOCKABLE,NEMA 3R, L- WWW.CRENG.CO (N)LOAD )20 (10)IQ8PLUS-72-2-US --- I � i i UL LISTED SIDETAP MICROINVERTERS (El100A/2P CONTRACTOR INFO SUBPANEL BREAKER TO UTILITY I ( 4.�b OVERHEAD BRANCH-3 ---- I L---- �� ------------- -- _ FEED 10 CANADIAN N ---- SOLAR:CS6R-0OOMS-HL ♦ r - J EXISTING WIRE RUN THROUGH CONDUIT mum 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 1J6GEC,BARE AWG#12.SKU.0-12-RAW-300,THHN 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 COPPER FREE AIR �_ ��� 1-#8 AM,EGC THWN-2 CANADIAN IN 314"OR LARGER PVC IN 3/4"OR LARGER PVC BONDED EXISTING I-------- IN3/4"OR LARGER PVC CONDUIT MODULE MANUFACTURER CONDUIT CONDUIT LIFER TIE IN z SOLAR (E)GROUNDING ELECTRODE CONDUCTOR#6 BARE COPPER MODULE MODEL CS6R-40OMS- ELEMENT ENERGY LLC. HL 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 MODULE(W) 400 PH:(631)779 7993 MODULE PTC(W) 376.70 NOTE: services@e2sys.com MODULE Isc(A) 13.85 REVENUE GRADE KWH PRODUCTION METER CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 Licence-ME-52689 STANDARDS. (MASTER ELECTRICIAN) MODULE VQc(V) 36.80 Licence-HI-67461 MODULE Imp(A) 12.99 NOTE: (SUFFOLK HOME IMPROVEMENT) MODULE Vmp(V) 30.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE 12.000KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CORRECTION CURRENT FACTOR FOR ADJUSTED CURRENT # QTY. AMPACITY RATING (°C) Photovoltaic System EQUIPMENT WIRE LOCATION WIRE APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO Y SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY 400 LEGION AVE, MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description IDate 2 AC MICROINVERTER TO AC DISCONNECT EXTERIOR WALL 2 12 30 90° 12.10 0.96 1 28.80 15.13 A INITIAL DESIGN I 3/23r2o24 3 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 12.10 0.96 1 72 15.13 Al UPDATED DESIGN 1 3/27/2024 A.2 I UPDATED DESIGN 1 3/30/2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 OPPORTUNITY JOE CONSTANTIN-GUILD 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 12.10 0.96 1 28.80 15.13 PROJECT# NA DATE DRAWN 3/302024 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 24.20 0.96 1 52.8 30.25 DRAWN BY ER 7 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 24.20 0.96 1 72 30.25 SHEET# PV-40 TITLE 8 AC ELECTRICAL 3LD 9 AC BACKFEED FUSE SIZING BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.21A @ 240V MAX. CONTINUOUS OUTPUT 1.21A @ 240V ��OF NEW, �P O�MANiq� � 24.20 X 1.25 = 30.25AMPS 40A FUSES-OK (N)6OA FUSED AC 12.10 X 1.25 = 15.13AMPS 20A FUSES-OK co �O 9G, xr DISCONNECT * A. SQUARE D D322NRB r OC WITH 20 A FUSES. g DLU AVVG*12,SKU:0-12-RAW-300,THHN KNIFEBLADE, n LU (10)IQ8PLUS-72-2-US - 1-#8 AWG,EGC THWN-2 LOCKABLE,NEMA 3R, m 09912E Z MICROINVERTERS IN 3/4'OR LARGER PVC CONDUIT ILL LISTED 2(P BRANCH-1 gIe �OA CTRIGP� 10 CANADIAN N q�L RG SSIQNP� SOLAR:CS6R-400MS-HL 3-#6 AWG,THWN-2 STAMPED 03/29/2024 1-#B EGC,THWN-2 IN 3/4"OR LARGER PVC (E)10DARATED MAIN BREAKER CONDUIT (END FED) (E)100A RATED THESE DRAWINGS ARE SUBJECT TO SUB PANEL COPYRIGHT PROTECTION BY US LAW. IPH,12D240V SOH2 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT ENPHASE (E)200A RATED (E)UTIUTV RENEWABLES ENGINEERING INC (N) MAIN SERVICE PANEL METER COMBINER BOX MODEL IPH 120240V 60HZ NO#X2-IQ-AM1-240-4 (E)20DA 12P MAIN BREAKER Current CELL WIRELESS (TOP FED) MODEM COMM, Renewable,`''. IQGATEWAY Engineering (10)IQBPLUS-72-2-US - (N)LOAD MICROINVERTERS (N)15A* (N)60A FUSED SIDE TAP CURRENT RENEWABLES AC DISCONNECT ./�. ENGINEERING INC. BRANCH-2 SQUARE D D322NRB 1760 CHICAGO AVE SUITE 10 CANADIAN NV WITH 40A FUSES, . . FSOLAR:CS6R-400MS-HL KNIFEBLADE, PHONE RIVERSIDE-1 92507 PHONE.(951)<OS-1733 I(N)20. LOCKABLE,NEMA 3R, WWW CRENG.CO /1 (NI LOAD (10)IQ8PLUS-72-2-US --- UL LISTED SIDE TAP MICROINVERTERS c (N)20�� SUBPANELBREAKER CONTRACTOR INFO To unury V.fbn OVERHEAD BRANCH-3 �� FEED 10 CANADIAN N SOLAR:CS6R-4OOMS-I L EX STING HARE RUN THROUGH CONDUIT [mom 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 AWG#12,SKU:Q-12-RAW-300,THHN 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 C Z SYS� 1-#8 AM,EGC THWN-2 CANADIAN IN 3/4"OR LARGER PVC N 3/4"OR LARGER PVC IN 3/4-OR LARGER PVC CONDUIT MODULE MANUFACTURER SOLAR CONDUIT CONDUIT _ (E)GROUNDING ELECTRODE CONDUCTOR#6 BARE COPPER MODULE MODEL CS6R-4OOMS- ELEMENT ENERGY LLC. HL 7470 SOUND AVENUE,MATTITUCK, M NEW YORK,11952 MODULE(W) 400 PH:(631)779 7993 MODULE PTC(W) 376.70 NOTE: services@e2sys.com MODULE Isc(A) 13.85 REVENUE GRADE KWH PRODUCTION METER CERTIFIED TO ANSI C12.1-2008 OR ANSI CA 2.20 Licence-ME-52689 STANDARDS. (MASTER ELECTRICIAN) MODULE Voc IV) 36.80 Licence-HI-67461 MODULE Imp(A) 12.99 NOTE: (SUFFOLK HOME IMPROVEMENT) MODULE Vmp IV) 3D.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE 12.000KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CORRECTION CURRENT FACTOR FOR ADJUSTED CURRENT q QTY. AMPACITY RATING (°C) Photovoltaic System EQUIPMENT WIRE LOCATION WIRE FACTOR APPLIEDTO MORETHAN3 CONDUCTOR APPLIED TO Y SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY 400 LEGION AVE, MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO AC DISCONNECT EXTERIOR WALL 2 12 30 90° 12.10 0.96 1 28.80 15.13 A INITIAL DESIGN 3/2 312 0 2 4 3 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 12.10 0.96 1 72 15.13 Al UPDATED DESIGN 1 312712024 A 2 UPDATED DESIGN 1 3/30/2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 LDRAWNBY /oEcorvsrANnN-GUILD 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 12.10 0.96 1 28.80 15.13 NA 3/30/2024 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 24.20 0.96 1 52.8 30.25 ER7 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 24.20 0.96 1 72 30.25 PV-5.0 8 AC ELECTRICAL SLD 9 AC MATERIAL LIST pFNEbyy �Q�ooE M_ �� ELECTRICAL EQUIPMENTS D w 0 QTY. PART TYPE PART NUMBER DESCRIPTION 2 099128 2 30 MODULE CS6R-40OMS-HL CANADIAN SOLAR CS6R-40OMS-HL CTRICP� 30 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US AR°�SS%ONP`' 1 COMBINER X2-1 Q-AM 1-240-4/4C ENPHASE COMBINER BOX X2-IQ-AM1-240-4/4C STAMPED03/29/2024 2 AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED THESE DRAWINGS ARE SUBJECT TO — COPYRIGHT PROTECTION BY US LAW. 4 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS EXPRESSLY FORRBIBI PRODUCTIO ANY FORM IS EXDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. oCurrent Renewabies Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO BREAKER / FUSES CONTRACTOR INFO QTY. PART TYPE PART NUMBER DESCRIPTION 2 BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) Imum- 1 FUSES 40A FUSES GENERAL 40A FUSES CZSYSSU 1 FUSES 20A FUSES GENERAL 20A FUSES ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 RACKING (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168A XR100, RAIL 168" BLACK Permit Package 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 JOE CONSTANTIN-GUILD 42 CLAMPS & GROUNDING UFO-CL-01-Al UNIVERSAL MODULE CLAMP, BLACK 36 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL KW Grid Tied Photo 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE Photovoltaic System 84 ATTACHMENTS QM-HUG-01-M1 HALO ULTRAGRIP, MILL 400 MATTITUCK,LEGION NY 11952 84 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev I Description Date 84 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE A INITIAL DESIGN 3/23/2024 A I UPDATED DESIGN 3/27/2024 A2 UPDATED DESIGN 3/30/2024 OPPORTUNITY IOECONSTANTIN-GUILD PROJECT# NA DATE DRAWN 313 012024 DRAWN BY ER SHEET# PV-6.0 TITLE BOM OF NEW C9 OpE MANi�9 * D W n PHOTOVOLTAIC 2� D99128 • '' 1 ' ' 1 1• F— VV CTR%GP� ARO SS1oNP� 690.12 STAMPED 03/29/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR TURN RAPID PV SYSTEM AC DISCONNECT WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. SHUTDOWN SWITCH TO RATED AC OUTPUT CURRENT THE "OFF" POSITION TO AC •' •' • 1 • SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current Renewables AND REDUCE SHOCK _ _ Engineering HAZARD IN THE ARRAY PM DUAL POWER SOURCES CURRENT RENEWABLES 690.56(c)(1)(B) NG INC. • , SOURCE PHOTO- • VOLTAIC 1E760 CF CAGIO AVE SUITE J-13,RIVERSIDE CA 92507 ■ , 1 OUTPUT CURRENT 1 ■ PHONE:(951)-405-1733 _ WWW CRENG.CO NORMALAC OPERATING VOLTAGE / VOLTS CONTRACTOR INFO 690.54 OPTIONAL SOLAR LOAD CENTER ARRAY CZSYS° ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, �J/B NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN)WARNING" Licence-HI-67461 INVE■ ■ OUTPUT • • (SUFFOLK HOME IMPROVEMENT) D• NOT RELOCATE THIS NEC 690.31(G)(3)&(4),CRC R324.7 Solar Individual OVERCURRENT DEVICE Permit Package (UNLESS BUSBAR IS FULLY RATED) L - • 705.12(D)(2) PHOTOVOLTAIC POWER • JOE CONSTANTIN-GUILD EVERY 10'ON CONDUIT AND ENCLOSURES 12.000KW Grid Tied Photovoltaic System NOTES. 400 LEGION AVE, MATTITUCK,NY 11952 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. Rev Description Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 3/23/202 A, UPDATED DESIGN 4 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR 3/ /2024 A UPDATED DESIGN 1 3/303D/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OPPORTUNITY IOE CONS7ANTIN-GUILD B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. PROJECT# NA C. AERIAL FONT. DATE DRAWN 3/3012024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY E.R THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-7 0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. of NEWN _ C P 00E MAN/�v o�� r— • D W m o99129 LU2 CTRIrG1 R1U' ARO�ss1oNP� CAUTION STAMPED 03/29/2024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewabies Engineering CURRENT RENEWABLES PV ARRAY ENGINEERING INC. W 1760 CHICAGO AVE SUITE SUB PANEL > J-13,RIVERSIDE CA 92507 Q PHONE.(951)-405-1733 AC DISCONNECT Z WWW CRENG CO FIR _0 CONTRACTORINFO 0 W J MAIN SERVICE PANEL mum UTILITY METER CZSYS8 AC DISCONNECT ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATiITUCK, COMBINER NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL JOE CONSTANTIN-GUILD PANEL IS AC DISCONNECT PER NEC690.17 12.000KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/2 312 0 241 A.1 UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY E.R SHEET# PV-7.1 TITLE PLACARD 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 MICROINVERTER CHART 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO CONTRACTORINFO 5 LE a a nt EZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 6NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.000KW Grid Tied 8 Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 9 Al UPDATED DESIGN 3272024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY ER 1 O SHEET# PV-8.0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS: a COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. AC REPRODUCTION IN ANY FORM IS 2. SAFETY PLAN MUST BE MARKED BEFORE JOB AC DISCONNECT EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN MSP MAIN SERVICE PANEL RENEWABLES ENGINEERING INC. 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET �M UTILITY METER Current IN CASE OF EMERGENCY O Rei-ewables PERMANENT ANCHOR — EngineeringNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC JB JUNCTION BOX CURRENT RENEWABLES NAME: EEO TEMPORARY ANCHOR ENGINEERINGINC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 ADDRESS: PHONE.(951)-405-1733 IL INSTALLER LADDER WWWCRENG.CO SAFETY COACH CONTACT INFORMATION S❑ STUB-OUT CONTRACTOR INFO NAME: ADDRESS: ® SKYLIGHT NO LADDER ACCESS (STEEP GRADE mom ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE OR GROUND LEVEL OBSTRUCTIONS) EZSYS AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR RESTRICTED ACCESS WORKING SAFELY. ELEMENT ENERGY LLC. CONDUIT 7470 SOUND AVENUE,MATTI7ITUCK, NEW YORK,11952 NAME SIGNATURE GAS GAS SHUT OFF PH:(631)779 7993 services(•ale2sys.cos.cam Licence-ME-52669 20 WATER SHUT OFF (MASTER ELECTRICIAN) Licence-HI-67461 SERVICE DROP (SUFFOLK HOME IMPROVEMENT) 7 O POWER LINES Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.000KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 DATE. TIME Al UPDATED DESIGN 327/2024 A.2 UPDATED DESIGN 313012024 OPPORTUNITY I JOE CONSTANTIN-51LILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY E.R SHEET# PV-9.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all The site supervisor shall forecast the weather conditions at the Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below). If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure.Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission, location of suitable restroom facilities with COPYRIGHT PROTECTION S LAW REPRODUCTION IN ANY FORM IS S uneven, loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. • Elevated work involving the moving or maneuvering of solar If Offsite,add location name and address: bars locked in the open position,A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure leaned a ainst a structure). Workers. Forecasted weather maximum temp(degrees F): Contact your Site Supervisor n RelneW a :i@5 • Additional notes: Crew leader responsible for communication with the client: Engineering Name: Mobile Equipment • Client and public is excluded from work area by barricades(N/A, CURRENT RENEwABLES • Only Qualified operators will operate equipment,operators must Yes, No): Heat Related Illness Prevention Phone: ENGINEERING INC. maintain a certification on their person for the equipment being Employees shall have access to potable drinking water that is 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13 RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE(951)-405-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: wwwCRENG CO P l 9 P 1 PP q Y 9 9 • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift.Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public. Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: 1dMn* • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees C SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: u • A site-specific plan for fall prevention and protection is required • Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete.a fall rescue plan must be outlined and • Crew member(name/title): New employees must be acclimatized. New employees will be of what happen and when. 7470 SOUND AVENUE,MATTITUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and connect Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift. Employees must take Licence-ME-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-W-67461 Asbestos-containingTransite piping ACP Do not disturb REQUIRED to allow employees an break period the need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) ( )PP 9( )- Y P Y FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an JOE CONSTANTIN-GUILD electrically safe condition(de-energized)unless approval has • If yes,list specific tasks and protection in place. What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 12.000KW Grid Tied • Service drops and overhead electrical hazards will be • If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: indentified and protected from contact as necces water(location/address): Photovoltaic System sa EQP(name and tile): 400 LEGION AVE, • Who will replenish the drinking water(name): MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 3/23/2024 A UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 3/30/2094 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN ,�tr CanadianSolar ENGINEERING DRAWING(mm) CS6R-40OMS-HL/I-VCURVES Rear View Frame Cross Section A-A ,� 14' t3 _.._ _.__._.13 12 12 35 _ 11 11 THESE DRAWINGS ARE SUBJECT TO to _ to .--.._-_.._ _______ COPYRIGHT PROTECTION BY US LAW. 9 _ 9 REPRODUCTION IN ANY FORM IS 614,9 ---- -- s _. s ..._.__ __ -_ __ _ EXPRESSLY FORBIDDEN WITHOUT PRIOR 7 7 _- ___. WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 5 5 3 a Mounting Hole Current v o L__.. _ .vI v 3+ry, 5 10 15 20 25 3o 3540E WS fiO 5 10 15 20 25 30 35 40 45 50 55 rA Renewables - lowwm: 5Y■ Engineering ■ aw w1w 25'C■ HiKu6 (All-Black) 31 - eaaw'�w'm `-c s _ ■ 4m - e5'c■ CURRENT RENEWABLES • 2oow'_ ENGINEERING INC. ALL BLACK MONO PERC 1760 CHICAGO AVE SUITE ELECTRICAL DATA I STC* MECHANICAL DATA J-13,RIVERSIDE CA 92507 380 W " 405 W CS6R-380/385/390/395/400/405MS-HL Specification Data PWWW CRENG CO 1733 CS6 R-380 1 385 1 390 1 395 1 400 1 405 M S-H L Nominal Max.Power(Pmax) 380 W 385 W 390 W 3%W 4W W 405 W Cell Type Mono-crystalline CONTRACTOR INFO Opt Operating Voltage(Vmp)30.0 V 301 V 30.4 V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X Sill Opt Operating Current(Imp)12.69 A 1 Z.77 A 12.84 A 12.91 A 12.99 A 13.07 A Dimensions 1722 it 1134 x 35 mm Industry Leading Product Warranty on Materials Open Circuit voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V (67.8 x"A x 1.38 in) MORE POWER ( Years and Workmanship* Short Circuit Current(Isc) 1355 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 22.4 kg(49.4lbs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti-ref- Module power u to 405 W lective coati no 405 W p y /`5 Operating Temperature 1 ODO (IEC/UL) Frame Anodized aluminium allay, Y Module efficiency up to 20.7% f � � C�S T SA _. 25 Linear Power Performance Warranty* Max.System Voltage 10ooV(IEC/UL) )-Box IP68,3 bypass diodes Years Module TYPE 2(UL 61730/000V) Fire Performance Cable 4 mm'(IEC),12 AWG(UL) ® Of CLASS C(IEC 61730) ELEMENT ENERGY ATTI Lower LCOE&system cost 1"year power degradation no more than 2% - Connector T6,MC4,MC4 EV02 or MC4 EV02A 7470 SOUND AVENUE,MATTITUCK, Max.Series Fuse Rating 25 A NEW YORK,11952 Subsequent annual power degradation no more than 0.55% Application Classification Class A Cable Len th + PH:(631)779 7993 APP g 1550mm(61Ain)()/1100mm(43.3irq(� pricluding Connector) *Subject to the terms and conditions contained in the applicable Canadian Solar Limited power Tolerance 0-+10 W _--_ _ services@e2sys.com Comprehensive LID/LeTID mitigation Warranty,sta tement.Also this 25-year limited product warranty is available only for prod- ucts installed and operating on residential rooftops in certain regions. *Under Standard Test conauons;MTQ of Irradiance of 10DO W/rr11,spectrum AM 15 and cell temps Per Pallet 30 pieces Licence-M E-52689 technology,up to 50%lower degradation ...................... .-....................................................... -- --- - ratreof25'G (MASTER ELECTRICIAN) - Per Container(40'HQ)780 pieces MANAGEMENT SYSTEM CERTIFICATES* *For detailed information,please contact your local Canadian Solar sales and Licence-H I-67461 technical representatives. (SUFFOLK HOME IMPROVEMENT) ISO 90012015/Quality management system Better shading tolerance ISO 14001:2015/Standards for environmental management system ISO 4SW1:2018/International standards for occupational health&safety ELECTRICAL DATA INMOTM Solar Individual • C56R-380/385/390/395/400/405M5-HL TEMPERATURE CHARACTERISTICS PRODUCT CERTIFICATES Permit Package MORE RELIABLE IEC 61215/IEC 61730 Jr CE Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data CEC listed(US California)/FSEC(US Florida) Opt Operating Voltage(Vmp)28.1 V 28.3 V 28A V 28.6 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0.34%/°C UL 617M/IEC 61701/IEC 62716 JOE CONSTANTIN-GUILD Takee-way Opt.Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Voc) -0.26%/°C Minimizes micro-crack impacts = Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/°C l/SP. C ■ p 9 12.000KW Grid Tied - cv�s` � V= Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A Nominal Module Operating Temperature 42 t 3°C L •The specific certificates applicable to different module types and markets will vary, *Under Nominal Module operating Temperature(NMOT),irradiance of sw W/rry spectrum AM 1.5, Photovoltaic otovolta is System Heavysnow load u t0 8100 Pa, and therefore not all of the certifications listed herein will simultaneously apply to the ambient temperature 20'C,wind speed 1 m/s. *** p products PARTNER SECTION p wind load u to 5000 Pa* t you 400 LEGION AVE, p [o confirm the specific certificates available for your Product and applicable in the regions :...............................................................•............................•..............."'•..: in which the products will be used. i MATTITU CK,NY 11952 ............................................................................................................................... i CSI SOLAR(USA)CO.,LTD.B eornmitted to providing high quality Rev Description Date solar photovoltaic modules,solar energy and battery storage solutions to A INITIAL DESIGN 3/23/2024 customers.The company was recognized as the No.1 module supplier for *The specifications and key features contained in this datasheet may deviate slightly from our actual quality and performance/price ratio In the IHS Module Customer Insight Products due to the on-going innovation and product enhancement.CSI Solar Co.,Ltd.reserves the A 1 UPDATED DESIGN 312712024 Survey.Over the 20 right to make necessary adjustment to the information described herein at any time without further A 2 UPDATED DESIGN 3/30/2024 rvey past years,it has successfully delivered over 70 GIN notice. •For detailed information,Please refer to the installation Manual. Of premium-quality solar modules across the world. Please be kindly advised that PV modules Should be handled and Installed by qualified people who OPPORTUNITY JOE CONSTANTIN-GUILD have professional skills and please carefully read the safety and installation instructions before using ...................................................................................................................._.._........................................................................................................................................ our PV modules. i PROJECT# NA :......_.........................................................................................................: CSI SOLAR(USA)CO..LTD. ............................................................................................................................................................................................................ .................................................. DATE DRAWN 3/3 012 0 2 4 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94598,USA I www.CSisolar.com/na I service.ca@csisolar.com J DRAWN BY E R CSI SOLAR(USA)CO.,LTD. Aug 2022 I All rights reserved I PV Module Product Datasheet v1.1 C25_F23 1 NA SHEET# PV-11 D TITLE MODULE SPEC ENPHASE. IQ8 and IQ8+ Microinverters Commonly used module pairings' W 235-350 235-440 Module compatibility _ To meet compatibility,PV modules must be within maximum input DC voltage and maximum module Ip listed below. Module compatibility can be checked at httos://enphawzomrnstallers/microinve ters/calculator MPPT voltage range V 27-37 27-45 O THESE DRAWINGS ARE SUBJECT TO Operating range V 16-48 18-58 COPYRIGHT PROTECTION BY US LAW. Minimum/Maximum start voltage V 22/48 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Maximum input DC voltage V 50 80 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Maximum module I A 20 Current Over voltage class DC port — 11 Renewabtes DC port backfeed current mA 0 Engineering PV array configuration - 1.1 ungrounded array;no additional DC fide protection required;AC side protection requires maximum 20 A per branch circuit. 7 CURRENT RENEWABLES Peak output wait VA 245 300 ENGINEERING INC. _ 1760 CHICAGO AVE SUITE Maximum continuous output power VA 240 290 J-13.RIVERSIDE CA 92507 PHONE:(951)405-1733 Nominal grid voltage(L-L) V 240.split-phase(L-0.180` WWW.CRENG.CO IQ8and IQ8+ Microinverters Easy to install Minimum and Maximum grid wltaga' v 211-264 CONTRACTORINFO • Lightweight and compact with plug- Maximumoontia+aa output current A 1.0 1.21 - Our newest 108 Microinverters are the industry's first microgrid-forming,software-defined and-play connectors Nominal frequency H2 60 powernv cien with split-phase power conversion capability to convert o power ie AC • Power line communication(PLC) 47-68 power efficiently.The brain of the semiconductor-based microinverter is our proprietary Extended frequency range Hz between components ---_--.___._ application- __.._._- spec ' integrated circuit ASIC,which enables the miCroinverter to operate in imam AC short-circuit Halt arrant over grid-tied or off-grid modes.This chip is built using advanced 55-nm technology with high-speed Faster installation with simple two-wire Arms 2 Cc SYS digital logic and has superfast response times to changing bads and rid events.alleviating cabling three cycles t9 09 Po n9 9 9 9 9 constraints on battery sizing for home energy systems. Maximum units per 20A(L-ubranch _ 16 13 circuit3 High productivity and reliability Produce power even when the grid is Total harmonic distortion % <5 ELEMENT ENERGY 7470 SOUND AVENUE,MATATTTTUCK, down* Overvoltage class AC port - • NEWYORK,11952 PH:(631)779 More than one million cumulative hours AC port backfeed current mA 30 services@e2sys.cos.com of testing Power factor setting _ W Licence-ME-52689 Class II double-insulated enclosure Grid-tied facto.(adjustable) - 0 .(�( D.es (MASTER ELECTRICIAN) Power ) leading legging Licence-HI-67461 Part of the Enphase Energy System, 108 Series Microinverters redefine Optimized for the latest high-powered 108 Series Microinverters integrate with the reliability standards with more than one PV modules Peak efficiency % 97.7 (SUFFOLK HOME IMPROVEMENT) 10 Battery,10 Gateway,and the million cumulative hours of power-on CEC weighted efficiency % 97 Enphase App monitoring and analysis testing,enabling an industry-leading Solar Individual warranty limited warn[y of up to 25 years. Microgrid-forming Nighttime power consumption mW 23 25 • Compliant with the latest advanced Permit Package grid support" Ambient temperature range -40'C to 60'C(-40'F to 140'F) • Remote automatic updates for the JOE CONSTANTIN-GUILD latest grid requirements Relative humidity range 4%to 100%(condensing) r MCa Configurable to support a wide range DC connector type • 12.000KW Grid Tied of grid profiles Dimensions(H•W.D) 212 mm(8.3 in)•175 mm(6.9 in)•30.2 mm(1.2 in) Meet CA Rule 21(UL 1741-SA)and IEEE' Photovoltaic System Connect PV modules quickly and easily I08 Series Microinverters are UL Listed Weight 1.08 kg(2.381bs) to 108 Series Microinverters using the as PV rapid shutdown equipment and 1547:2018(UL 1741-SB 3'°Ed.) Cooling Naturalconveetion-no fens 400lEGION AVE, included 0-DCC-2 adapter cable with conform with various regulations.when MATTITUCK,NY 11952 plug-and-play MC4 connectors. installed according to the manufacturer's NOTE: Approved for wet locations Yes instructions. 108 Micmmverters canrwt be mixed with Pollution degree PD3 Rev Description Date previous generations of Enphase micromverters (107 Series.106 Series.antl soon)in the same Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure A INITIAL DESIGN 323/2024 system. ID Gateway is r Environmental category/UV exposure rating NEMA type 6/Outdoor A UPDATED DESIGN 3/27I2024 squired to change the default A.2 UPDATED DESIGN 3/30/2024 'Meets UL 1741 only when matelled with ID System Comrolbr 2. grid profile at the time of irptelletion to rfre6t 'US ant 038 wpport spla-phase,240 V Ioatallatlons only. local Auttwnty Having Jurisdiction(AHJ) OPPORTUNITY JOE CONSTANTIN-GUILD mqu-mems. ro no.nro.c.a pci.c,mw. PROJECT# NA O 2D23 Enphase Energy.AlI rphts reserved.Enphess,the a and CC Iogos,10,and cousin other marks toted at _ _ (2)Nv�i,ui.dt•pe,.,ga�e�be•.r•,�ao o•rana �.a raa,.e i pry me vtati, httpaJ ase/enph .com/trademark-usage-guidelines ere trademrxs e of Enptuse Energy.Inc in. the US and other coumnes.Data subject to change. 108SP-12A-DSH-00207-2.0-EN-(b-2043.10-13 108SP-12A-D5H-00207-2.0-EN-US-2023-10-13 DATE DRAWN 3/3012024 DRAWN BY E.R SHEET A PV-11.1 TITLE MICROINVERTER SPEC Enphase IQ Combiner 4/4C Data Sheet MODEL NUMBER Enphase Networking IQ Combiner 4(X-10-AM1-240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20 a 0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the 10 Battery system and IQ System Controller 2 and to deflect heat IQ Combiner 4C(X 10 AM1 240 4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1 06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enphase The Enphase IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the 10 Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) THESE DRAWINGS ARE SUBJECT TO IQ Gateway and Integrated LTE-M1 cell --- -- --- - ------ -- ----- - Q Combiner 4/4 C Ensemble Communications Kit Includes COMMS-KIT-01 and CELL MODEM-M1-06-SP 05 with 5-year Sprint data plan for COPYRIGHT PROTECTION BY US LAW. modem(included only with IQ Combiner 4C) COMMS-CELLMODEM-Ml-06 Ensemble sites REPRODUCTION IN ANY FORM IS CELLMODEM-Ml-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan EXPRESSLY FORBIDDEN WITHOUT PRIOR X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-M7-06-AT-05 4G based LTE-Ml cellular modern with 5-year AT&T data plan_ —_ WRITTEN APPROVAL FROM CURRENT Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240.BR250,and BR260 circuit breakers. RENEWABLES ENGINEERING INC. X-IQ-AM1-240-4C into a single enclosure and streamlines IQ BRK-10A-2-240V Circuit breaker 2 pole.IOA.Eaton BR210 BRK-15A-2 240V Circuit breaker,2 pole,15A,Eaton BR215 microinverters and storage installations by BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 Current BRK-15A-2P-24OV-0 Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support providing a consistent, pre-wired solution for BRK-20A-2P-24OV-8 Circuit breaker,2 pole 20A,Eaton BR2206 with hold down kit support 0_��n Renewable residential applications. It offers up to four EPLC-Ol Power kite carrier(communication bridge pair), pair _ ------ -__XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C Engineering 2-pole input circuits and Eaton BR series I XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-Ot) ENPHASE CURRENT RENEWABLES bUSbar assembly. XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board;PCB}for Combiner 4/4C ENGINEERING INC. �• I X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 n : ELECTRICAL SPECIFICATIONS PHONE(951)-405-1733 VJWW.CRENG.CO Smart Raving Continuous duty i CONTRACTORINFO Includes IQ Gateway for communication and control system voltage 120/240 VAC,60 Hz 1 Includes Enphase Mobile Connect cellular modem Eaton BR series busbar rating 125 A (CELLMODEM-M1-06-SP-05),included only with IQ Max.continuous current rating 65 A Combiner 4C Max.continuous current rating(input from PV/storage) 64A Includes solar shield to match Enphase IQ Battery Max fuse/circuit rating(output) 90 A Ann* aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) �_ SYS Flexible networking supports Wi-Fi, ------ T Max total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included Ethernet,or cellular Envoy breaker 10A or 15A rating GE/Siemens/Eaton included • Optional AC receptacle available for PLC bridge ---- ------------------ ------- --------- — - - ELEMENT ENERGY LLC. • Provides production metering and consumption Production metering CT 200 A solid core pre-installed and wired to 10 Gateway 7470 SOUND AVENUE,MATTITUCK, monitoring Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers NEW YORK,11952 PH:(631)779 7993 MECHANICAL DATA services@e2sys.com Dimensions(WaHxD) 37.5 x 49.5 x 16.8 cm(14.75•x 19 5'x 6.630).Height is 21.06'(53.5 cm)with mounting brackets. Licence-ME-52689 Simple Weight 7 5 kg(16 5 1bs) (MASTER ELECTRICIAN) Licence-HI-67461 Centered mounting brackets support single Ambient temperature range -40"Cto+a6"C(-40°to 115-F) (SUFFOLK HOME IMPROVEMENT) stud mounting ( Cooking Natural convection,plus heat shield Supports bottom,back and side conduit entry Enclosure environmental rating Outdoor.NRTL-certified,tified,NEMA type 3R,polycarbonate construction Solar Individual Up to four 2-pole branch circuits for 240 VAC • plug-in breakers(not included) wire sizes 20 A to 50 A breaker inputs 14 to 4 AWG copper conductors Permit Package 60 A breaker branch input.4 to 1/0 AWG copper conductors X-IQ-AM1-2404C 80A total PV or storage branch circuits Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground 14 to 1/0 copper conductors JOE CONSTANTIN- UILD Always follow local code requirements for conductor sizing. Reliable Altitude To 2000 meters(6,560 feet) _ 12.000KW Grid Tied Durable NRTL-certified NEMA type 3R enclosure INTERNET CONNECTION OPTIONS --- --�- �� ----- stem S y Five-year limited warranty Integrated Wi-Fi 802.11b/g/n Photovoltaic7 Two years labor reimbursement program coverage Cellular CELLMODEM-Mt-06-SP-05,CELLMODEM-Ml-06-AT-05(4Gbased LTE-Ml cellular modem) Note that an Enphase 400LEGIONAVE, included for both the IQ Combiner SKU's Mobile Connect cellular modem is required for all Ensemble installations Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) MATTITUCK,NY 11952 UL listed t• COMPLIANCE Rev Description Date Compliance,10 Combiner UL 1741,CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class 8-ICES 003 A INITIAL DESIGN 31231202' Production metering:ANSI C12.20 accuracy class 0.5(PV production) • Consumption metering.accuracy class 2.5 A UPDATED DESIGN 3/27/2024 Compliance,IQ Gateway ILL 60601-1/CANCSA 22.2 No.61010-1 A2 UPDATED DESIGN 3/30/2D24 L2 X-10 AM1-240 d— ----- OPPORTUNITY IOE CONSTANTIN-GUILD To learn more about Enphase offerings,visit en Phas€&� E N PH AS E. To learn more about Enphase offerings,visit enohase.com E N P H AS E. PROJECT# NA C 2022 Enphase Energy.All rights reserved.Enphase the Enphase logo IC Combiner 4/4C,and other names are trademarks of DATE DRAWN 313012024 Enphase Energy.Inc.Data subject to change.02-14-2022 DRAWN BY E.R SHEET# PV-11.2 TITLE COMBINER SPEC !`� IRON RIDGE XR Rail° Family XR Rail° Family The XR Rail°Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads,while minimizing material costs. Depending on your location,there is an XR Rail®to match. Over their lifetime,solar panels experience countless .. THESE DRAWINGS ARE SUBJECT TO extreme weather events. Not just the worst storms In years, j - REPRODUCTION IN ANYOFORM Its LAW. but the worst storms in 40 years. High winds capable of aaaa EXPRESSLY FORBIDDEN WITHOUT PRIOR FROM CURRENT ripping panels from a roof, and snowfalls weighing RNEW ALES EO VAL E B NGIINEERING INC. enough to buckle a panel frame. — f, XR Rails@ are the structural backbone - - XR10 XR100 XR1000 Current preventing these results.They resist uplift, ` _ Renewables protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among and efficiently transfer loads Into the rail,designed for regions with light or mounting rail.tt supports a range of solar mounting rails.It's bulk to handle " Engineering building structure.Their superior no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. spanning capability requires fewer CURRENT RENEWABLES roof attachments,reducing the 6'spanning capability 10'spanning capability 12'spanning capability ENGINEERING INC. number Of roof s,reducing Moderate load capability Heavy load capability Extreme load capability 1760 CHICAGO AVE SUITE • Clear&black anodized finish Clear&black anodized finish Clear anodized finish PHONE: RIVERSIDE-1 92507 PHONE:RIVERSIDE CA 93 and the amount of Internal splices available Internal splices available Internal splices available WWW CRENG CO installation time. CONTRACTOR INFO Rail Selection --- - - The table below was prepared in compliance with applicable engineering codes and standards.'Values are IN based on the following criteria:ASCE 7-16,Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof a Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. EZSYSA • • , •- ELEMENT 7670 SOUND AVENUE,MATTITUCK, Snow(PSF) • � � NEW Y 9 PH:(631)779 79 7993 Force-Stabilizing Curve 90 services@e2sys.com Licence-ME-52689 Sloped roofs generate both vertical and lateral 120 (MASTER ELECTRICIAN) '.a forces on mounting rails which can cause them to bend and twist The curved shape of XR Rails None Licence- IMPROVEMENT) is specially designed to increase strength in both 140 XR10 XR100 XR1000 (SUFFOLK HOME MPREMENT) directions while resisting the twisting.This unique feature ensures greater security during extreme 160 weather and a longer system lifetime. Solar Individual 90 Permit Package 120 20 140 JOE CONSTANTIN-GUILD 16600 12.000KW Grid Tied 90 Photovoltaic System 30 160 • 400 LEGION AVE, MATTITUCK,NY 11952 90 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails' are IronRidge@offers All XR RailO are made of 6000-series 40 Rev Description I Date compatible with a range of tiff leg aluminum alloy,then protected with an 160 A INITIAL DESIGN I 3r23t2024 FlashFoot' and options for flat anodized finish.Anodizing prevents surface A t UPDATED DESIGN 24 A other pitched roof ■■■ roof mounting and structural corrosion,while also providing 80 160 3rz72o attachments. applications. a more attractive appearance. _ - A.z UPDATED DESIGN 3/3012024 120 160 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT 0 NA - •Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. DATE DRAWN 3/3012024 DRAW ER 2023 - - r .a SHEET BY PV-11.3 TITLE RAIL SPEC /lr IRONRIDGE QuickMount' ® Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home,solar attachments • • - THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. • , COPYRIGHT PROTECTION BY US LAW. Y FORM IS Due to recent innovations, many asphalt shingles _ _ _ . exPR�ss�TFOReiooEN WITHOUT PRIOR have bonded courses.A mount that protects without - WRITTEN APPROVAL FROM CURRENT the need to pry shingles can really speed things up. RENEWABLES ENGINEERING INC. Halo UltraGriV(HUG'-')is here to respect the roof. • /''�F ' Its Halo is a cast-aluminum barrier that encases the O CurrentUltraGrip,our industrial-grade.foam-and-mastic ReneWab{e5 seal.This allows HUG to accelerate the installation Engineering process and provide the utmost in waterproofing Hit the rafter?Good to ! Miss the rafter?Try it again. Still no luck?Install the rest. protection.Give your roof a HUG.` When • • • •• on. • or . more CURRENT RENEWABLES ENGINEERING INC. Only 2 RD Structural Screws are needed. rafter I,,found.install 3rd and final screw secure six screws to deck mount it. 1760 CHICAGO AVE SUITE RIVERSIDE CA 92507 PHONE WWW.CRENG.CO Muni-Tiered Waterproofing HUG"utilizes a multi-tiered stack of CONTRACTOR INFO components to provide revolutionary Trusted Strength & Less Hassle waterproofing protection.The Halo cast- aluminum,raised-perimeter foundation _M4 surrounds the UltraGrip base—a foam- Structural capacities of HUG" were reviewed in _ asked mastic seal combination that many load directions, with racking rail running --- �- prevents water intrusion by adhering seali ng with the shingle surface. cross slope or up slope in relation to roof pitch. CZSYS9. Halo UltraGrip'"is part - For further details, see the HUG certification of the QuickMount• letters for attachingto raft and decking. _-- product lie.n rafters g. ELEMENT ENERGY 7470 SOUND AVENUE,MATTIATTITUCK, - ---- a designed the HUG, in combination NEW YORK,11952 IronRld g g PH:(631)779 7993 UltraGrip'Seal Technoi with the RD Structural Screw to streamline services@e2sys.com 71 HUG UltraGrip utilizes astate-of- installs,which means the following: Licence-ME-52689 art seal design that uses a unique.. r � r (MASTER ELECTRICIAN) foam-and-mastic combination.Thg Licence-HI-67461 foam-backed adhesive provides V No prying shingles (SUFFOLK HOME IMPROVEMENT) entirely new flashing system that No roof nail interference conforms and adheres to every nook. L Year warranty and cranny ofcomposllonShingles, ( ductguaranteedtree No pilot holes necessary Solar Individual filling gaps and shinglestep4owns - is • No sealant(in most cases) Permit Package (up to 1/8'in height). No butyl shims needed 10E CONSTANTIN-GUILD LoadingAttachment Structural Water Seal UL 2703 12.000KW Grid Tied Design Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG'to the roof ratters.the roof HUG has been and certified for the UL 441 Section UL 2703 mechanical Rev De—pT., Date • • deck,or both with our custom-engineered A INITIAL DESIGN 3/23/2024 RD(rafter-or-deck)Structural Screw.The RD tested and rated to compliance with 27"Rain Test"and and bonding O Triple Rated&Certified with an EPDM sealing washer,completing a 1 UPDATED DESIGN 3/27/2024 Structural Screw anchors HUG to the root' support 1004(Ibs)of the International TAS 100(A)-95 requirements.See to Respect the Roof'" A 2 UPDATED DESIGN 3/30/2024 P ' UL 2703,441(27) the stack of waterproofing barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual OPPORTUNITY JOE CONSTANTIN-GUILD In irtak TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more into. PROJECT# NA ra DATE DRAWN 3/30/2024 ra DRAWN BY E.R SHEET# PV-11 4 O�2023 IronRidge.Inc.All rights reserved.Visit www.ir-patents.corn for patent inforniation.Version 1.03 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. 28357 Industrial Blvd. A C d ayw H( ar94545 ayw 23 Hayward,CA 94545 IRONRIDGE IronRidge.com IRONRIDGE IronRidge.om3 Attn:Corey Geiger,COO, IronRidge Inc. Date: September 7"',2021 The parameters and adjustments allowed in the span tables are defined as the following: 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1. THESE DRAWINGS ARE SUBJECT TO Re:Structural Certification and Span Tables for the IronRidge Flush Mount System COPYRIGHT PROTECTION S LAW REPRODUCTION IN ANY FORM IS S 2. Wind speed shall conform to ASCE 7-16 Fig.26-5-1 B(for Risk Category 11)and applicable state&local EXPRESSLY FORBIDDEN WITHOUT PRIOR This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The count /cit amendments to the IBC No special wind topographic features are included and both topographic WRITTEN APPROVAL FROM CURRENT P PY Y Y PeRENEWABLES ENGINEERING INC. contents of the letter shall be read In its entirety before applying to any project design.The Flush Mount System is a coefficient(Ke..)and wind ground elevation factor(Ke)are taken as 1 0 proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape y g pp y 3 Snow load used in the span tables is the ground snow and shall conform to ASCE specified Fig,now and Current orientation and set parallel to the underlying roof surface. PV modules are supported b extruded aluminum XR Rails applicable state&local county/city amendments t0 the IBC. If the local jurisdiction specified snow load is in the and secured to the rails with IronRidge mounting clamps The XR Rails are side mounted to a selected roof format of a flat roof snow, it shall first be converted to a ground snow following the local building code/ RelnewaWes attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables.No special snow conditions are considered Engineering that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding, retention,or ponding snow. No rain-on-snow surcharge load is components are shown in Exhibit EX-0015. considered.The span tables do not apply to buildings which are intentionally kept below freezing,kept just above freezing,Or unheated. CURRENT RENEWABLES ENGINEERING INC. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 1760 CHICAGO AVE SUITE 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being. J-13,RIVERSIDE CA92507 listed below,for the load conditions and configurations tabulated in the attached span tables WWWCRENc eo 173s (a)For ground snow no greater than 42psf:S5 5 2.Og for Site Class A, B,C,&D. b For round snow greater than 65 sf SS<_1 0 for Site Class A.B.C, &D. CONTRACTOR INFO • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) ( ) 9 9 P 9 • 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:SS 5 1.5g for Site Class A,B,C, &D -- • 2020 Building Code of New York State(BCNYS-2020, Published in November 2019) • 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in • Report SEAOC Structural Engineer Association of V2-2017 Wind Design for Solar Arras which the zones share the same External Pressure Coefficients(GCp) Roof zones comprising each group along p ( g California)) g y with each roof zones size and location are depicted in Figures 2 and 3 below each span table. The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length.measured from the rail end to the nearest attachment point,shall CZSYSLi the respective loads and configurations listed,covering wind exposure categories B, C, &D. roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load P &configuration condition from the span tables.or 36 ELEMENT ENERGY ASCE 7-16 for gable&hip roof profiles, and roof slopes of 8°to 45'. The tabulated spans are applicable when the g 7470 SOUND AVENUE,MATTITTITUCK, NEW YORK,11952 following conditions are met. 7 Allowable span length in the charts may be multiplied by a factor of 1,08 if the rails are continuous over PH:(631)779 7993 a minimum of three spans services@e2sys.com Licence-ME-52689 1 Span is the distance between two adjacent roof attachment points(measured at the center of the (MASTER ELECTRICIAN) attachment fastener) 8 No splices are allowed in the rail cantilever For each XR splice type install per the following requirements Licence-HI-67461 a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2/3 of end spans (SUFFOLK HOME IMPROVEMENT) 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system). Spans are Calculated b) BOSS Splice can be installed at any location within a span based on 2 rail systems.and conservatively deemed acceptable for 3 rail systems. Solar Individual 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If Permit Package 3 The underlying roof slope, measured between the roof surface and horizontal plane.is 80 to 450 such conditions are encountered contact support@ironrdge com JOE CONSTANTIN-GUILD 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from grade,does not exceed 30 feet. 12.000KW Grid Tied Photovoltaic System 5- A clearance from the underside of the array to the roof surface of 2'minimum shall be provided and the 400 LEGION AVE, height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not MATTITUCK,NY 11952 exceed 10 Rev Description Date 6. Module length and area shall not exceed the maximum values listed on the respective span tables. A INITIAL DESIGN 3/2312024 At UPDATED DESIGN 312712024 7, All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush P NPD PORITY I J DESIGN 3/30/2024 Mount Installation Manual and other applicable standards for the general roof construction practice PROJECT T U# or coNSTANrw GUILD PROJEC # NA DATE DRAWN 3130/2024 DRAWN BY E R ,:c-2021 IronRidge.Inc NY Flush Mount System Certification Letter-1 C 2021 IronRidge.Inc NY Flush Mount System Certification Letter-2 SHEET# PV-11.5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward.CA 94545 Hayward,CA 94545 RON RI DGE 1-800-ge.co 23 I RON RI DGE IronRi ge.cor23 IronRidge.com IronRidge.com 10. Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations(orphan modules)using modules with a length greater than 67.5",CAMO The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no clamps shall not be installed in regions that experience ground snow loads of 70psf and greater.Such consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting scenarios are shown by asterisks in the applicable span tables. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the b) CAMO will function within a module's design load ratings.Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. THESE DRAWINGS ARE SUBJECT To COPYRIGHT PROTECTION BY US LAW. CAMO meets the dimensional requirements shown in the figure below and that the module selected is REPRODUCTION IN ANY FORM IS suitable for the environmental conditions of a particular project. y 2021 21 0 9 0 EXPRESSLY FORBIDDEN WITHOUT PRIOR Sincerely, P1� NG N Xe �0-419 /--- WRITTEN APPROVAL ENT NEWABLES ENGINEERING NC E Module Gloss/Cells 0 f- UJ 15:45: 16 Current VP <0 �, _._ I Renewables �U�ESSIONt�'04 -0 7'00' Engineering home Compat�bi4ty X=1.2-2.2mm Y=1 CURRENT R LES 5-40mm Gang Xuan, PE ENGINEERING 60 HICGINC. AGO AVE SUITE Y Senior Structural Engineer J-13.RIVERSIDE A 92507 PHONE.(951)d05-1733 WVVW.CRENG.CO —T F,gure t CAMO Module Frame Dimensional Requirements CONTRACTORINF Span values for Exposed and Edge module conditions,as defined below, are included in the attached span tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; (2)The span value determined by site wind speed and ground snow load.Additionally, irrespective of the lesser EZSYS span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 1. Exposed Module conditions: NEW YORK,11952 PH:(631)779 7993 services@e2sys.com 89 A module is defined as Exposed(per Section 29 4 4 of ASCE 7-16)if the distance from any of its free Licence- (MASTER ELECTRICIAN) N) edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave, ridge, rake,or Licence-HI-67461 hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from Its free edge to any (SUFFOLK HOME IMPROVEMENT) other adjacent array or panel is greater than 4 feet. Solar Individual The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed Permit Package Modules JOE CONSTANTIN-GUILD 2. Edge Module conditions: 12.000KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave, ridge. rake.or hip)is less than 2 times the height of the array(2h2) where h2 is measured from the roof surface to the top surface of the module. 400 LEGION AVE, MATTITUCK,NY 11952 The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Rev Description Dale Additionally, if the roof edge is the eave or ridge.only the rail nearest to that roof edge shall be considered q INITIAL DESIGN 3/23/2024 for this span adjustment A.1 UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD 'c%2021 IronRidge Inc NY Flush Mount System Certification Letter-3 C 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-4 PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY ER SHEET# Pv-11 6 TITLE CERTIFICATION ii (1(\ ROOF M I INT SOLAR PERMIT PACKAGE CODE INFORMATION N _ O v THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC ��Of Ely1k J O E CO N STA N T I N-GUILD POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: ��Q O�91 A. 0 2020 NEW YORK BUILDING CODE-BUILDING * �o - 2020 NEW YORK BUILDING CODE-RESIDENTIAL 12.750 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-EXISTING BUILDING l% 2020 NEW YORK BUILDING CODE-PLUMBING 400 LEGION AVE MATTITUCK NY 11952 2020NEWYORKBUILDINGCODE-MECHANICAL F�� 106793 2020 NEW YORK BUILDING CODE-ENERGY CONSERVATION 'QOFESSIONP 2020 NEW YORK BUILDING CODE-FUEL GAS Exp:9/30/2025 2020 NEW YORK BUILDING CODE-ACCESSIBILITY 2020 NEW YORK FIRE PREVENTION CODE STAMPED 06/14/2024 BUILDING INFORMATION 2017 NEWYORK NATIONAL ELECTRICAL CODE THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 2 STORY HOUSE SINGLE FAMILY RESIDENCE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U AHJ : TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC. ROOF:COMP SHINGLE APN:1000142000200000000 PV SYSTEM SUMMARY: Current Renewables SYSTEM SIZE (DC) STC:425 x 30= 12.750KW DC Engineering PTC: 398.1 x 30=11.9430KW DC SYSTEM SIZE (AC) 9.600KW AC @ 240V CURRENT RENEWABLES MODULES (30)JINKO SOLAR: JKM425N-54HL4-B ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENGCO MICRO-INVERTERS ENPHASE: IQ8MC-72-M-US AERIAL VIEW VICINITY VIEW CONTRACTORINFO MICRO-INVERTERS QTY 30 TILT 21°, 30°, 30°, 23°,23° AZIMUTH 132°, 222°,42°,222°, 42° ROOF COMP SHINGLE CZSYSU RAFTER/TRUSS SIZE 2"X10"/2"X8"RAFTER @ 16"O.C./2X4 RAFTER @ 24"O.C. RAFTER @ 24"O.C. f. ATTACHMENT TYPE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP WITH IRONRIDGE XR-100 { ELEMENT ENERGY LLC. EXISTING 200 AMPS MSP WITH 200 AMPS MAIN �r 7470 SOUND AVENUE,MATTITUCK, Q. '�, NEW YORK,11952 MAIN SERVICE PANEL PH:(631)779 7993 BREAKER ON TOP FED services@e2sys.com INTERCONNECTION LINE SIDE TAP, BACKFEED BREAKER Licence-ME-52689 + 4 (MASTER ELECTRICIAN) OCPD RATING 50 AMPS yY Licence-HI-67461 1 (SUFFOLK HOME IMPROVEMENT) UTILITY PSEGLI Solar Individual GENERAL NOTES: Permit Package 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 3 PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED SHEET INDEX JOE CONSTANTIN-GUILD 4, ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5 ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 12.750KW Grid Tied 6, ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS Geccel 2300 CLEAR SEALANT 7 THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL 400 LEGION AVE, GROUNDING ELECTRODE PV-3.0 STRUCTURAL MATTITUCK,NY 11952 10, EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PV-4.0 ELECTRICAL 3LD Rev Description Date 11, A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS PV-5.0 ELECTRICAL SLD A INITIAL DESIGN 3/2312024 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM A 1 UPDATED DESIGN 3/27/2024 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM A z 1 UPDATED DESIGN 6/14/2024 COMPLIES WITH 690.35. PV-7-0 SIGNAGE OPPORTUNITY IOE CONSTANTIN-GUILD 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703, PV-7.1 PLACARD 16 INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PROJECT# NA 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.0 M ICROI NVERTE R CHART DATE DRAWN 6/14/2024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY E R 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/81,ABOVE ROOF SURFACE. PV-9.0 SAFETY PLAN 19, IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE SHEET# ALLOWED IN PROTECTED LOCATIONS WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH PV-10.0 SAFETY PLAN TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0+ SPEC. SHEETS 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: .1 PATHWAYS:NOT L NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND ' SEPARATE ROOF PLANES, �� NEw FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON PROPERTY LINE �E Z' ALL BUILDINGS. �P O AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER o0��j A' Z9a DRIVEWAY SIDE OF THE ROOF. I FENCE 1 86' I * F FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM __ ___________ _ MSP MAIN SERVICE PANEL CLI 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE r II SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING ( { n 1ki THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE t • •• SUB PANEL y OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS I' DRIVEWAY " 1 8'-10 I SUB J'FO 106793 - ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS �p WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR CV I AC DISCONNECT SSI�NP MECHANICAL EQUIPMENT. R324.6.2 SETBACK AT RIDGE: w ' $1'-11" Exp:9/30/2025 COMBINER FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 STAMPED 06/14/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A Q 52-911 JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. 41 COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 Z REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A O /t I a MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A \ WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. /n ,% RENEWABLES ENGINEERING INC. 23'-7" ROOF OBSTRUCTIONS R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS w AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED J 14� ROOF ACCESS POINT THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 4:7 __—__�__�__ __—__—_____—__—__ __ __—__—__�_ Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. /I 149'-1 0" Renewables A PATHWAY ON STREET FENCE/GATE Engineering PROPERTY LINE OR DRIVEWAY SIDE OF ROOF B FIRE ACCESS POINT CURRENT RENEWABLES ENGINEERING INC. WEArEmA PHONE E (951)O AVE SUITE 36"ACCESS PATHWAYS PNONEV sssl-4DS�DE CA 33507 WWW.CRENG.CO 18"ACCESS PATHWAYS CONTRACTOR INFO NOTES: ENLARGE VIEW 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND MEASUREMENTS. (N)COMBINER 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS EZSYS INCORPORATED INTO THE 2017 NEC AND UL (N)AC DISCONNECT STANDARD 1741. 3. EXISTING ROOF VENT SHOULD NOT BE (E) UTILITY METER ELEMENT ENERGY LLC. COVERED. 7470 SOUND AVENUE,MATTITUCK, (E) MAIN NEW YORK,11952 PH:(631)779 7993 NOTE: SERVICE PANEL services@e2sys.com REVENUE GRADE KVVH PRODUCTION METER Licence-ME-52689 CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 ROOF OBSTRUCTION (MASTER ELECTRICIAN) STANDARDS. c Ac "M Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) SUB W � (E) Sub PANEL Solar Individual Q Permit Package Z O JOE CONSTANTIN-GUILD V� (N)COMBINER 12.750KW Grid Tied J Photovoltaic System 400 LEGION AVE, - MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 A 1 UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 IT E�1/3 AN 36"ROOF ACCESS POINT DRAWN BY ER ROOF LINE 36" ROOF ACCESS POINT SHEET# Pv-zo 1 TITLE SCALE: 2" = 1'-0" SITE PLAN ARRAY AREA LEGEND - EAVETO ROOF ROOF TOTAL AZIMUTH #OF RIDGE ARRAY AREA AREA AREA AREA P��OF NEW,,, ROOF ROOF TYPE MODULES DIMENSION (Sq.Ft.) COVERED BY COVERED BY (Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) UM UTILITY METER #1 COMP SHINGLE 132 9 14.58 189.09 2111 8.96 #2 COMP SHINGLE 222 16 1 13,50 1 126.06 1 2111 s.97 MSP MAIN SERVICE PANEL #3 COMP SHINGLE 42 1 5 1 13.50 105.05 2111 4.98 29.86 #4 COMP SHINGLE 222 1 5 8.50 105.05 1 2111 4.98 #5 COMP SHINGLE 42 5 &50 105.05 2111 4.98 SUB SUB PANEL �Op 106793 �V �c AC DISCONNECT SSI�NP Exp:9/30/2025 (N)#30 JINKO SOLAR:JKM425N-54HL4-B COMBINER STAMPED 06/14/2024 .1 B JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS ROOF#5 MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N)COMBINER ROOF OBSTRUCTIONS (N)AC DISCONNECT Current (E) UTILITY METER R Renewables (E) MAIN SERVICE PANEL Engineering CURRENT RENEWABLES RING INC. w c Ac urn ROOF#3 E 6D HI AGO AVE SUITE ROOF#4 J-13,RIVERSIDE CA 92507 Q sue PHONE(951)-405-1733 WWW.CRENG.CO z (E) SUB PANEL CONTRACTOR INFO I IT- LU (N)COMBINER EZSYS STRUCTURAL NOTES ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE NEW YORK,11952 COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE PH:(631)779 7993 services@e2sys.com PROPOSED PV INSTALLATION ONLY. Licence-ME-52689 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. (MASTER ELECTRICIAN) Licence-HI-67461 . .7HI 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS (SUFFOLK HOME IMPROVEMENT) 3, MUST FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. Solar Individual 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL Permit Package ROOF#1 ROOF#2 CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR JOE CONSTANTIN-GUILD INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE 12.750KW Grid Tied INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY Photovoltaic System INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 400 LEGION AVE, - ROOF 1:2x10 RAFTERS @ 16" OC SPACING WITH MAX MATTITUCK,NY 11952 UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. Rev Description Date - ROOF 2&3: 2x8 RAFTERS @ 16" OC SPACING WITH MAX A INITIAL DESIGN 3/23/2024 UNSUPPORTED SPAN EQUAL OR LESS THAN 14 FT. Al UPDATED DESIGN 3/27/2024 - ROOF 4&5: 2x4 RAFTERS @ 24" OC SPACING WITH MAX A UPDATED DESIGN 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 RO O 2 F P LA N DRAWN BY E R SHEET# PV-21 TITLE SCALE: 3/3Z = 1'-0" ROOF PLAN MAX ROOF ROOF ROOFING ATTACHMENT TYPE FRAMING FRAMING OC PENETRATION PENETRATION MAX OF NEW y~ NO TILT TYPE TYPE SIZE SPACING PATTERN SPACING OVERHANG *�'�P�O�RS q, �4o0,p ROOF 1 21 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2„x10 16 FULLY STAGGERED 64vw ROOF 2 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 1611 FULLY STAGGERED 64" ROOF 3 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 211 106793 x8" 16" FULLY STAGGERED 64" 2411 ,o ROFESSIONP ROOF 4 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 2411 FULLY STAGGERED 72" Exp:9/30/2025 ROOF 5 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" STAMPED 06/14/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables JINKO SOLAR: JKM425N-54HL4-B = Engineering CURRENT RENEWABLES IRONRIDGE XR-100 ENGINEERING INC. 1760 CHICAGO AVE SUITE TABLE PENETRATION PHONE (951IDECA925D7 PHONE.(951)ADS-1733 GUIDE FOR INSTALL lvvww CRENG CO CONTRACTORINFO 41" ; (, (E) COMP SHINGLE TWO OR MORE ROWS OF PANELS IRONRIDGE UICKMOUNT HALO ULTRA GRIP 2.5"MIN.IEMBED. O Q I I I I I I I I I I I I I I I I I I I I C2SYS9 I I I I I I I I I I I I I I I I I I I I#14 X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING ELEMENT ENERGY LLD. 7470 SOUND AVENUE,MATTITUCK, RAFTER 3 NEW YORK,11952 PH:(631)779 7993 I I I I I I I I I I I I I I I I I I I I Licence-ME-52689 (E) 2°x10°/ 2"x8" RAFTER @ 16"O.C. I I I I I I I I I I I I I I I I I 1 I I (MASTER L ELECTRICIAN) (SUFFOLK HOME IMPROVEMENT)EMENT)ENLARGED VIEW 2X4 RAFTER @ 24" O.C. STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE XR-100 Permit Package IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ONE ROW OF PANELS JOE CONSTANTIN-GUILD JINKO SOLAR: JKM425N-54HL4-B 12.750KW Grid Tied =:H �:I.i c:6 c=l=. c:2. =2= =I:. I Q_ SEE ENLARGED VIEW I I I I I I I I I I I I I Photovoltaic System I I I I I I I I I I I I I 400 LEGION AVE, \ MATTITUCK, NY 11952 (E)2"X4" RAFTER@ 24" O.C. ` FULLY STAGGERED STACKED/STAGGERED Rev escnption Date A INITIAL DESIGN 312312024 Al UPDATED DESIGN 3/27/2024 A 2 UPDATED DESIGN 6114/2024 ATTACHMENT DETAILS (E) COMP SHINGLE OPPORTUNPROJECT Y oec°NSTANn" °"° PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY ER SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING (N)ENRHASE BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 1.33A @ 240V COMBINER BOX MODEL MAX. CONTINUOUS OUTPUT 1.33A @ 240V �� Y 26.60 X 1.25 = 33.25AMPS 40A FUSES-OK NO#X2-I0-AM1-2404 13.30 X 1.25 = 16.63AMPS 20A BREAKER-OK pF NEWO CELL V:IRE LESS �Q� OQE MA/y�R MODEM CORINIS 10 GATEWAY 41, CG MODULE MANUFACTURER 11NK0 SOLAR � m n W gN115A•im1 MODULE MODEL JKM425N-54HL4-13 099128 Z ^ I I MODULE(W) 425 NCO CTRICP� AWGM12.SKI 0-12RAW-300 THHN ,10)108MC-72-M-US - 1-96AWG.EGC THWN-2 MODULE PTC(W) 398.10 ADO MiCRO1NVERTERS SSIONP� IN 3WOR LARGER PVC CONDUIT tNj20AT MODULE Isc(A) 13.58 cN20A BRANCH-1 MODULE Voc(V) 38.95 STAMPED 06/14/2024 10 JINKO SOLAR.JKM42SN-54HL4-B N 1 I MODULE Imp(A) 13.13 --- ------------ L---- -------------- p( THESE DRAWINGS ARE SUBJECT TO ----- MODULE Vm V) 32.37 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR 3-#10 AWG.THWN-2 WRITTEN APPROVAL FROM CURRENT 1-#8 EGC.THWN-2 IE,'Oak RATED RENEWABLES ENGINEERING INC. IN 3i'4"OR LARGER PVC •+BREAK R CONDUIT IEND'ED) (EI 100A RATED SJe PANEL Current Renewables (N)ENPHASE • (E)MARArD MAIN Engineering • SERME PANEL NETER COMBINER BOX MODEL T +++++ p+ NO#X2-IO-AM1-2404 iT fE?�'2P CURRENT RENEWABLES /\ raN BREAKER CELL ,HIRE-ESS �.� (Toaa�, ® ENGINEERING INC. MODEtA C�, S BREAKER •2 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 10 GATEWAY PWWW CRENG CO 1733 00)Q8MC-724A-US - CONTRACTOR INFO MICROINVERTERS 15A_ (N160A FUSED rrl, AC DISCONNECT BRANCH-2 I SQUARE 0 0322NRS 1G JINKWITH 40A FUSES. (N)UNESIDE TAP VIA UL C+ S _AR:JKfal425N-SaHL4-B r KNIFEBLADE.LOCKABLE.NEMA 3R. LISTED CONNECTOR, --� I 'JL LISTED sJBPANEt BREAKER ,1CI+Q8MC-72-M-US --- m M+GROIN`:ERTERS T41� C2SYS9 BRANCH:-3 - -------- ---- I I FEED K�z L------- ------- � ---- ------- -- s3�R.JasMSaLaa �------ 1 EMMIG.WNEAM ELEMENT ENERGY LLC. THROJOHCON"T I 7470 SOUND AVENUE,MATTITUCK, 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 +46 GEC.SAW I NEW YORK,11952 1-#8 EGC.THWN-2 1-#8 EGC..THWN-2 t07?ERFREEA1R I PH:(631)779 7993 AWGR12..Sx:;.0-12stAwJ04 WN--, iN 3i4"OR LARGER PVC IN 14"OR LARGER PVC ��� IN L services@e2sys.com "BAT £t;C THWN-2 IN 3.4-3IR LARGER PVC CDNDJIT CONDUIT CONDUIT 'E,GROUNONG ELECTRODE Licence-M E-52689 CO'+DUCTOR'K'1EIARECIOPPER (MASTER ELECTRICIAN) Licence-HI-67461 NOTE_ (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A JOE CONSTANTIN-GUILD WIRE SCHEDULE STARTING STARTING ADJUSTMENT MAXIMUM TEMPERATURE 12.750KW Grid Tied AWG CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION FACTOR FOR ADJUSTED CURRENT Photovoltaic System ## EQUIPMENT WIRE LOCATION QTY. AMPACITY RATING (°C)WIRE FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO SIZE 310.15(B)(16) CONDUCTORS IN 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS 400 LEGION AVE, RACEWAY 310.15(B)(3)(a) IN RACEWAY MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO COMBINER EXTERIOR WALL 2 12 30 90° 13.30 0.96 1 28.80 16.62 A UPDATNITIAL ED ESIGN 3/27/2024 A.1 UPDATED DESIGN 3/27/2024 3 AC COMBINER TO POI EXTERIOR WALL 3 10 40 90° 13.30 0.96 1 28.80 16.62 A UPDATED DESIGN 6/14/2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.30 0.96 1 28.80 16.62 DATE DRAWN 6/14/2024 DRAWN BY E.R 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 26.60 0.96 1 52.8 33.25 -SHEET# PV-40 7 AC AC DISCONNECT TO P01 EXTERIOR WALL 3 6 75 90° 26.60 0.96 1 72 33.25 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 1.33A @ 240V (N)ENPHASE MAX. CONTINUOUS OUTPUT 1.33A @ 240V COMBINER BOX MODEL NO#X2-10-AM1-240-4 13.30 X 1.25 = 16.63AMPS 20A BREAKER-OK OF NE(.1, 26.60 X 1.25 = 3325AMPS 40A FUSES-OK �P�� MAN/ y0 CELL WIRE LESS (� �Q� �� r� MODEM COMMS MODULE MANUFACTURER JINKO SOLAR * � E Z VO GATE`AAY r W MODULE MODEL KM425N-54HL4- m LL 099128 Z MODULE(W) 425 MODULE PTC(W) 398,10 �A CTRIGP AWG#12,SKU.O-12RAW-300,THEN .��. MODULE Isc(A) 13.58 RO�SSIGNP� 0 0)108MC-72-M-US-- 1-08AWG.EGC THMM-2 MK;ROINVERTERS IN 3W OR LARGER PVC COIDIHT )20A MODULE Voc(V) 38.95 STAMPED 06/14/2024 BRANGWI Y2O/a MODULE Imp(A) 13.13 10 JINKO N SOLAR;JK W25N-54HL4-B MODULE V RE SUBJECT TO mp IV) 32.37 THESE DRAWINGS A COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 3-#10 AWG.THNM-2 RENEWABLES ENGINEERING INC. 1-#8 EGC,THWN-2 (Et 100A RATED IN 3/4"OR LARGER PVC MAIN BREAKER CONDUIT teD FED' ,EI1011ARATED Current S1>B , j �� aPa,.12Wr+xrsz � .�ertewables (N)ENPHASE (Ey2KKRATED Engineering ,E T-=R COMBINER BOX MODEL • u rl SERVICE w eaEr_R �; ,vR.,m�4Ov enlz NO#X2-10-AM1-240-4 ; CURRENT RENEWABLES wv sRE ENGINEERING INC. 1760 CHICAGO AVE SUITE R40DEfi5 COt�GiS ggLq /1� J-13,RIVERSIDE CA92507 /\ PHONE'.(951)-405-1733 • WWW.CRENG.CO VO GATE'W'AY (1o>KzaMc na�>u /� A CONTRACTOR INFO MICROINVERTERS (N)SOAFUSED �\ • 1 8RAN"..H-2 � t�♦1 AC DISCONNECT r1• 10 JINKO V .� SQUARE 40 D 0322NR6 {.) ,��, WITH RE FUSES. :� M LINESIDE TAP VIA UL SOLAR:JKM425N-54FIL4-B KMFEBLADE, 11.1-AigY. LOCKABLE,NEMA 3R. !E„�,a,� glum LISTED CONNECTOR _ (10 i iO3MC-72-M-US UL LISTED &WA�BREAKER MICR0IN'✓ERTERS {N,�.:� CTo UrLffy ZSYS9 BRANCS-3 t q� FEED 10 JINKO Y ELEMENT ENERGY LLC. SOLAR:JKM425N-54HL4-e ��WtR=RUN 7470 SOUND AVENUE,MATTITUCK, rRaiC.,Cavun' NEW YORK,11952 3-#8 AWG,THIMN-2 3-#6 AWG,THVVN-2 PH:(631)779 7993 1-#8 EGC.THWN-2 1-#8 EGC,THWN-2 services@e2sys.com AWG-12 SKU o-12-RAW-300 THHN IN 3W OR LARGER PVC IN 314'OR LARGER PVC Licence-ME-52689 1-98 A%VG E 3C THWN-2 IN 14-oR LARGER Pvc CONDUIT CONDUIT CONDUIT IEIGROUINDMG ELECTRODE (MASTER ELECTRICIAN) CONOUCTOR 46aARECOPPER Licence-HI-67461 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 12.750KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT Photovoltaic System EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO Y # QTY. SIZE AMPAC) RATING (`C) CONDUCTORS IN FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15{B)(1 6) RACEWAY 310.15(B){2){a) 310.15(B)(3)(a) IN RACEWAY 400 LEGION AVE, MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90' 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO COMBINER EXTERIOR WALL 2 12 30 90` 13.30 0.96 1 28.80 16.62 A INITIAL DESIGN 3/23/2024 3 AC COMBINER TO POI EXTERIOR WALL 3 10 40 90• 13.30 0.96 1 28.80 16.62 Al UPDATED DESIGN /14/2024 6 A UPDATED DESIGN 114/2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90' 13.85 0.96 1 28.80 17.31 OPPORTUNITY JOE CONSTANTIN-GUILD 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.30 0.96 1 28.80 16.62 PROJECT# NA DATE DRAWN 6/14/2024 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 26.60 0.96 1 52.8 33.25 DRAWN BY ER 7 AC AC DISCONNECT TO P01 EXTERIOR WALL 3 6 75 90` 26.60 0.96 1 72 33.25 SHEET# PV-50 TITLE ELECTRICAL SLD MATERIAL LIST FNE ELECTRICAL EQUIPMENTS *P�0�EMA1y���op* QTY. PART TYPE PART NUMBER DESCRIPTION _ w �30 MODULE CS6R-400MS-HL CANADIAN SOLAR CS6R-40OMS-HL y 099128 w 30 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US o CTRICP� 2 COMBINER X2-1 Q-AM 1-240-4/4C ENPHASE COMBINER BOX X2-IQ-AM1-240-4/4C A�OFEss'l NPR 1 AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED STAMPED 0611412024 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables _ Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE (951)-405-1733 VN/JJV.CRENG.CO CONTRACTORINFO BREAKER / FUSES QTY. PART TYPE PART NUMBER DESCRIPTION 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) 1 FUSES 40A FUSES GENERAL 40A FUSES CZSYSU 1 PV BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A FUSES ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 RACKING (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168A XR100, RAIL 168" BLACK Permit Package 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 JOE CONSTANTIN-GUILD 42 CLAMPS & GROUNDING UFO-CL-01-Al UNIVERSAL MODULE CLAMP, BLACK 12.75W Grid Tied Photo 36 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL Photovoltaic System 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 400 LEGION AVE, 84 ATTACHMENTS QM-HUG-01-M1 HALO ULTRAGRIP, MILL MATTITUCK, NY 11952 84 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev Description Date A INITIAL DESIGN 3/23/2024 84 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE Al UPDATED DESIGN 1 3/27/2024 A UPDATED DESIGN 1 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY ER SHEET# PV-6.0 TITLE BOM X c)F NEw MA ,�CO,p n n c, o PHOTOVOLTAIC SYSTEM 099 EQUIPPED WITH RAPID SHUTDOWN ZN�O�o CTRIGP� ��C9 690.12 RO Ss10NP� LWOLAR PV SYSTEM EQUIPPED STAMPED 06/14/2024 TH RAPID SHUTDOWN THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR TURN RAPID PV SYSTEM AC DISCONNECT WRITTEN APPROVAL FROM CURRENT SHUTDOWN SWITCH TO RATED AC OUTPUTCURRENT 39.90 AMPS RENEWABLES ENGINEERING INC. THE "OFF" POSITION TO AC AC NORMALOPERATING VOLTAGE1 VOLTS Current SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Renewables AND REDUCE SHOCK _ Engineering HAZARD IN THE ARRAY 690.56(C)(1)(B) PM DUAL • POWER • • SOURCES • CUR NET E NEW NCABLES ENGSECOND SOURCE PHOTO-VOLTAIC 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 RATED, 1 OUTPUT 39.90 PHONE:(951)-405-1733 WWW.CRENG.CO NORMALAC OPERATING VOLTAGE VOLTS 240 CONTRACTORINFO 69054 OPT'ONAL SOLAR LOAD CENTER ARRAY EZSYSU ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, J/^ NEW YORK,11952 [� PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) WARNING" Licence-HI-67461 INVERTER OUTPUT CONNECTION (SUFFOLK HOME IMPROVEMENT) • NOT RELOCATENEC 690.31(G)(3)&(4), CRC R324.7 Solar Individual • "WA _ Permit Package (UNLESS BUSBAR IS FULLY RATED)705.12(D)(2) PHOTOVOLTAIC POWER SOURCEJOE CONSTANTIN-GUILD EVERY 1U ON CONDUIT AND ENCLOSURES 12.750KW Grid Tied Photovoltaic System NOTES. 400 LEGION AVE, MATTITUCK, NY 11952 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. Rev Description Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 3/23/2024 A UPDATED DESIGN 3/27/2024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A UPDATED DESIGN 6/14/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OPPORTUNITY IOE CONSTANTIN-GUILD B. RED BACKGROUND COLOR WHITE TEXT AND LINE PROJECT# NA WORK. DATE DRAWN 6114/2024 C. AERIAL FONT. DRAWN BY E R 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THEETa PV-zo THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE TITLE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. A OF NEwY N1A 0 m w 099128 2 ZN�O CTRIC- SS% CAUTION STAMPED 0611412024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewabfes Engineering PV ARRAY CURRENT RENEWABLES SUB PANEL ENGINEERING INC. LLJ 1760 CHICAGO AVE SUITE COMBINER > J-13,RIVERSIDE CA 92507 Q PHONE.(951)-405-1733 Z VWM.CRENG.CO O CONTRACTORINFO 0 w J MAIN SERVICE PANEL UTILITY METER E2SYS8 AC DISCONNECT ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, COMBINER NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL JOE CONSTANTIN-GUILD PANEL IS AC DISCONNECT PER NEC690.17 12.750KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 A.1 UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E.R SHEET# PV-7.1 TITLE PLACARD 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 MICROINVERTER CHART 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current Renewables Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 VVWW.CRENG.CO CONTRACTORINFO 5EE Li EP.SYS9 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 6 NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.750KW Grid Tied 8 Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description IDate A INITIAL DESIGN 1 3/23/2024 9 A.1 UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 1 6/14/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E R 1 O SHEET# PV-8 0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS: c COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. Ac REPRODUCTION IN ANY FORM IS 2. SAFETY PLAN MUST BE MARKED BEFORE JOB AC DISCONNECT WRITTEEXPRESN YFORVALFRBIDDEN MCUR WITHOUT PRIOR STARTS AS PART OF THE PRE-PLAN WRITTEN APPROVAL FROM CURRENT MSP MAIN SERVICE PANEL RENEWABLES ENGINEERING INC 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET �M UTILITY METER Current O IN CASE OF EMERGENCY (z enewabies P PERMANENT ANCHOR Engineering NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC JB JUNCTION BOX CURRENT RENEWABLES NAME: ENGINEERING INC. TO TEMPORARY ANCHOR 1760 CHICAGO AVE SUITE ADDRESS: PHo EIV95SI-405-733507 IL INSTALLER LADDER WAW CRENG CO SAFETY COACH CONTACT INFORMATION STUB-OUT CONTRACTOR INFO NAME: MADDRESS: � SKYLIGHT NO LADDER ACCESS STEEP GRADE ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE OR GROUND LEVEL OBSTRUCTIONS) C2S T S8� SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. RESTRICTED ACCESS ELEMENT ENERGY LLC. CONDUIT 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 NAME SIGNATURE PH:(631)779 7993 GAs GAS SHUT OFF services@e2sys.com Licence-ME-52689 H2O WATER SHUT OFF (MASTER ELECTRICIAN) Licence-HI-67461 SERVICE DROP (SUFFOLK HOME IMPROVEMENT) 7 O POWER LINES Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.750KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description I Date A INITIAL DESIGN 1 3/23/2024 DATE. TIME. Al UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 1 6/14/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E.R SHEET# PV-9.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. • The safety of the Client and the Public must be maintained at all • The site supervisor shall forecast the weather conditions at the • Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below).If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure.Extensions le ladders laced on work zone through the use of barriers and/or si na e,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with COPYRIGHT PROTECTION R IS LAW. style P 9 9 9 P P P REPRODUCTION IN ANY FORM IS uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. • Restroom facilities will be(circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. • Elevated work involving the moving or maneuvering of solar • If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind Current L.� climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure Rene W abl e$ leaned against a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor • Additional notes: • Crew leader responsible for Communication with the client: Engineering Name: Mobile Equipment • Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment;operators must Yes,No): Heat Related Illness Prevention Phone: CURRENT R G INC. LES maintain a certification on their person for the equipment bein • Employees shall have access to potable drinking water that is ENGINEERING INC. pg Y P g 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13,RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): • All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE (951)-4o5-1733 WWW.CRENG.CO hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift.Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to • Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the • Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: ® —•-- • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees E Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: CZ SYS9U • A site-specific plan for fall prevention and protection is required • Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete;a fall rescue plan must be outlined and • Crew member(name/title): New employees must be acclimatized.New employees will be of what happen and when. 7470 SOUND AVENUE,MATTITUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and connect • Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift.Employees must take Licence-ME-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) Licence-HI • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are PROV • Asbestos-containing(Transite)piping(ACID)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and • Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed • Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an JOE CONSTANTIN-GUILD electrically safe condition(de-energized)unless approval has If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 12.75OKW Grid Tied • Service drops and overhead electrical hazards will be 0 If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: Photovoltaic System indentified and protected from contact,as neccessa . water(location/address): y EQP(name and tile): • Who will replenish the drinking water(name): 400 LEGION AVE, MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 3/23/2024 A UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN Sofia z www.jinkosolar.comPerformance t Dependence Building Your Trust S t',r:ar.-Vol:_gr t i'ovcr Vol la it 1:•uwc-at dr�!) <.r„ .,. Tiger Teo N-type 54HL4-B - I =`p 1 V •' ;z� THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 425 Watt REPRODUCTION IN ANY FORM IS drrta EXPRESSLY FORBIDDEN WITHOUT PRIOR m WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. I ' ! °° s ,° •s zo z> so ss w° ; b t -i ALL-BLACK MODtIE N_Type Current Rlenewables Positive power tolerance of 0—+3% Engineering IFC61 2 1 5 1201 6), iEc61730(201R7 "'0" '" CURRENT RENEWABLES TS09M11.2015: qua-ily management 4y'lcmMechanical Characteristics ENGINEERING INC. AGO AVE SUITE T SOi4(101:2(115. Envt runmonl ManaBruu•nl S,s:rm ,..�.- -�� U - ..•. '.I.� RIVERSIDE CA 92507 11 11 A 1760 CHIC r 1 J-13, I Sfl4 001:201R ... .. PHONE-.(951)-405-1733 occupational healih and salt y munagomcnt sys'ems 17.2x 11:;1 3umm 'F7.i9�I bl.6S�1.1R is ca: WWW.CRENG.CO CONTRACTORINFO Key Features Fmnt i.9mn,Anr.-R.flort ion Coal infi. H,gh lraosnaGi,c, Ltw ir'- 'l ami-•cr:•d Dias=n S)IBB Technology HO Hot 2.0 Technology CZSYSU 6rttrr IighT tt-apPing and cur cn rent llertion to improve Thr F-Ive modal, wi. b 11ol 2.0 ha, brtler ® wdule powrt'uctpu- and reliability. 2.0 rel iahi li*y and lnrrr I IhLF:Ih. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 godalr;s;,r ;h\I- : _. PH:(631)779 7993 services@e2sys.com PID Resistance Enhanced Mechanical Load Licence-ME-52689 ��It t'I•`t'llcn.. dut vz od verCnproces Ruarantrt; o ( ) L CerliPied to wiltslaod: wind load i'2400 P;,seal) and snow ka,mom Power lPun:1 1r51fP 32t4('p MASTER ELECTRICIAN via �mizcd mass-vu,ducl loin process and materials 21°'`' Licence-HI-67461 R sun r. load (59(q f'as,.ull. (SUFFOLK HOME IMPROVEMENT) 10.601. Solar Individual short- rn• :I,r; a.SR:t 10.9rr: Permit Package Durability Against Extreme Environmental \® rvercaE aosmvouulry oucta_,ns c-meeratur: Ci -r`= -> g C E ` JOE CONSTANTIN-GUILD �\ Cond i t i ons High �aL• mis' �sid autmar.'a resistalrre. :u aarmnm ser;. ta::�at;:� 12.750KW Grid Tied Photovoltaic System 1�mprrv:4tfr;urfl:ri":L u'�Wn] iL'Lif:.'9C LINEAR PERFORMANCE WARRANTY aoo LESION Tay-'-:a:'uc�:�tir.�,•r�l,e:lot• 0.0+6't'=c MA TTITUCK, NY 11952 - Rev Description Date lUflk 999t4 A INITIAL DESIGN 1 312/ 25 fear Product Wa rranty T A.1 UPDATED DESIGN 3/27/2024 *STC Lredianer 1000R''m ® Cell Tempe-ature 25' C AW1. A2 UPDATED DESIGN 6/14/2024 30 Year Linear Power Warrantv 1\70CT: Irradiant,, 8000•m ® Ambient lemperature 20` C A51=1.5 1,;.,1 il* d OPPORTUNITY OE CONSTANTIN GUILD PROJECT# NA WAS DATE DRAWN 6/14/2024 E veers 0• !]j0% Annual Degradation Over 30 years DRAWN BY E.R 1 as au C2021 Jinw S-lai Co.. Ltd. All rights reser,ec. SHEET# PV-11.0 Specifications included in this datesheet are suh,iect to change without notice. JK.k1125\-54HL4-B-F3C2-E\ i!PC 10:= TITLE MODULE SPEC ENPHASE. 1�11 IQ8MC Microinverter INPUT DATA r Commonly used module pairings w 260-460 Module compatibility _ To meet compatibility,PV modules must be within the following max.input DC voltage and max.module I . Module compatibility can be checked at https://enphase.comf*installers/microinverters/calculator. MPPT voltage range v 25-45 DRAWINGSTHESE Operating range V 18-58 COPYRIGHT PROTECTION BY US LAW. Min./Max.start voltage v 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Max.input DC voltage v 60 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.continuous operating DC current A 14 P Max.input DC short-circuit current A 25 Max.module) A 20 Current Overvoltage class DC port - x Renewables DC port backfeed current mA 0 Engineering PV array configuration - Ungrounded array;no additional DC side protection required:AC side protectior requires max 20 A per branch circuit OUTPUT DATA r;VAC CURRENT RENEWABLES ENGINEERING INC. Peak output power VA 330 315 1760 CHICAGO AVE SUITE IQ8MC Microinverter PH E (951IDECA92507 E8sy t0 inst811 Max.continuous output power vA 320 310 PHONE: 951)-0OS-1733 WWW.CRENG.CO Our newest 108 Series Microinverters are the industry's first microgrid-forming',software- Lightweight and compact with plug-and-play Nominal grid voltage 11-0 V 240,split-Phase(L-L),180` 208,single-phase(L-0.120` defined microinverters with split-phase power conversion capability to convert DC power to connectors Min./Max.grid voltage= V 211-264 183-229 CONTRACTOR INFO AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC)between application-specific integrated circuit(ASIC).which enables the microinverter to operate in components Max.continuous output current A 1.33 1.49 grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Nominal frequency xx 60 • Paster installation wrath simple two-wire I, digital logic and has superfast response times to changing loads and grid events,alleviating cabling constraints on battery sizing for home energy systems. Extended frequency range Hz 47-68 AC short circuit fault current over three High productivity and reliability AC Arms 2.70 r_ w�U Enphase • Produces power even when the grid is down' Max.units per 20 A(L-L)branch circuit, - 12 10 ` More than one million cumulative hours of Total harmonic distortion ELEMENT ENERGY LLC. testing % `5 7470 SOUND AVENUE,MATTITUCK, • Class It double-insulated enclosure Overvoltage class AC port - III NEW YORK,11952 PH:(631)779 7993 Part of the Enphase Energy System, 108 Series Microinverters redefine Optimized for the latest high-powered PV AC port backfeed current mA 18 services@e2sys.com 108 Series Microinverters integrate with reliability standards with more than one modules Power factor setting 1.0 (MASTER ELEC- Licence-ME-52689 TRICIATRICIAN) the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Licence-HI-67461 Enphase App monitoring and analysis testing,enabling an industry-leading Microgrid-forming Grid-tied power factor(adjustable) - 0.85 leading...0.851agging software. limited warranty of up to 25 years. (SUFFOLK HOME IMPROVEMENT) • Complies with the latest advanced grid Peak efficiency % 97.4 972 support CEC weighted efficiency % 97.0 96.5 • Solar Individual Remote automatic updates for the latest grid s requirements Nighttime power consumption mW 33 2" Permit Package Configurable to support a wide range of grid n L_CERTIFIED-A profiles Ambient temperature range -40°Cto65°C(-40"Fto149"F) JOE CONSTANTIN-GUILD • Meets CA Rule 21(UL 1741-SA)and Relative humidity range 4%to 100%(condensing) Connect PV modules quickly and easily I08 Series Microinverters are UL Listed IEEE 15472018(UL 1741-SE) to the 108 Series Microinverters that have as PV rapid shutdown equipment and DC connector type Staubli MC4 12.750KW Grid Tied integrated MC4 connectors. conforms with various regulations when NOTE: Dimensions(H•W•D);Weight 212 mm(8.3")•175 Trim WEI')•30.2 mm(1.2");1.1 kg(2.43lbs) Photovoltaic System installed according to the manufacturer's instructions. IQB Microinverters cannot be mined together with Coding Natural convection-no fans previous generations of Enphase mlcrolnverters (107 Series,106 Series,and so on)in the same Approved for wet locations;Pollution degree Yes;PD3 4OO LEGION AVE, system. Enclosure Class 11double-insulated.corrosion-resistant polymeric enclosure MATTITUCK, NY 11952 IQ Microinverters ship with default settings that meet North America's IEEE 1547 interconrl Environ.category;W exposure rating NEMA Type 6;outdoor Rev Descnption Date standard requirements Region-specific adjustmentsmay be requested by an Authority A INITIAL DESIGN 3/23/2024 Having Jurisdiction(AH)or atilay representative Al UPDATED DESIGN 3127/2024 *Meets UL 1741 only when installed with IQ System.Controller 2 or 3. An IQ Gateway is required to make these changes CA Rule 21(UL 1741-SA).UL 62109-1.IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01. during Installation. Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and A.2 UPDATED DESIGN 6/1 412 02 4 C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. OPPORTUNITY l0E CONSTANTIN-GUILD 02024 Enphase Energy.All rights reserved.Enphase.the a and CC logos,l0.and certain other marks leted at (1)No enforced DC/AC ratio. htlm,//enchwe.com/Jademwk-usace-awdeii are trademarks of Enphase Energy,Inc.in the U.S.and other countries. (2)Nominal voltage range can be extended beyond nominal I°required by the utility. PROJECT# NA Data subject to change. IQBMC-MC4-DSH-00049-4.0-EN-US-2024-02-09 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch In your ama. IQBMC-MC4-DSH-00049-4.0-EN-US-2024-02-09 DATE DRAWN 6/14/2024 DRAWN BY E.R SHEET# PV-11.1 TITLE MICROINVERTER SPEC ROOF MOUNT SOLAR PERMIT PACKAGE CODE INFORMATION THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC �� OF NEW, J 0 E CO N STANTI N-GUILD POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: ��P0�R1._A. 2020 NEW YORK BUILDING CODE-BUILDING * Qo 12.750 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-RESIDENTIAL w Y 2020 NEW YORK BUILDING CODE-EXISTING BUILf34NG b, 2020 NEW YORK BUILDING CODE-PLUMBING 400 LEGION AVE, MATTITUCK106793 , NY 11952 2020 NEW YORK BUILDING CODE-ENERGY 2020 NEWYORK BUILDING ICONSER�A-fl-� �( �CAL �OpROFESSIONP���� 2020 NEW YORK BUILDING CODE-FUEL GAS Q L53 UIV� Exp:9/30/2025 2020 NEW YORK BUILDING CODE-ACCESSIBILITY STAMPED 09/11/2024 2020 NEW YORK FIRE PREVENTION CODE BUILDING INFORMATION 2017 NEW YORK NATIONAL ELECTRICAL CODE S E P 13 2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 2 STORY HOUSE SINGLE FAMILY RESIDENCE REPRODUCTION WANE FORM IS nTT7� �7/� �7 EXPRESSLY FORBIDDEN WITHOUT PRIOR f.�1111�Di1'i V DEPT.✓T. WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U AHJ : TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC. ROOF:COMP SHINGLE APN:1000142000200000000 TGZ� '-)F SOLM101-� PV SYSTEM SUMMARY: Current SYSTEM SIZE(DC) STC:425 x 30= 12.750KW DC Renewables PTC: 398.1 x 30=11.9430KW DC Engineering SYSTEM SIZE(AC) 9.600KW AC @ 240V CURRENTRENEWABLES MODULES (30)JINKO SOLAR:JKM425N-54HL4-B ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WW W CRENG.CO MICRO-INVERTERS ENPHASE: IQ8MC-72-M-US AERIAL VIEW VICINITY VIEW CONTRACTORINFO MICRO-INVERTERS QTY 30 TILT 21°,30°, 30°,23°,23° Y AZIMUTH 132°,222°,42°,222°,42° Ila Im nit ROOF COMP SHINGLE RAFTER/TRUSS SIZE 2"X10"/2"X8"RAFTER @ 16"O.C./2X4 RAFTER @ 24"O.C. RAFTER @ 24"O.C. - EZSYSA ATTACHMENT TYPE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP WITH IRONRIDGE XR-100 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH 200 AMPS MAIN jw NEW YORK,11952 BREAKER ON TOP FED " . PH:(631)779 7993 -s services@e2sys.com INTERCONNECTION LINE SIDE TAP/PV BREAKER Licence-ME-52689 O (MASTER ELECTRICIAN) CPD RATING 50 AMPS Licence-HI- ROV UTILITY PSEGLI (SUFFOLK HOME IMPROVEMENT) GENERAL NOTES: Solar Individual 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION ` Permit Package 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED SHEET INDEX JOE CONSTANTIN-GUILD 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 12.750KW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL PV-2.1 ROOF PLAN GROUNDING ELECTRODE 400 LEGION AVE, 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE PV-3.0 STRUCTURAL MATTITUCK,NY 11952 MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PV-4.0 ELECTRICAL 3LD Rev Description Date 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" PV-5.0 ELECTRICAL SLID A INITIAL DESIGN 3)23)2024 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM A 1 UPDATED DESIGN 3/27/2024 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM A 5 UPDATED DESIGN 9/12/2024 COMPLIES WITH 690.35. PV-7.0 SIGNAGE 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. OPPORTUNITY oecoNSTANnN-GUILD 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PV-7.1 PLACARD PROJECT# NA 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.0 MICROI NVERTER CHART DATE DRAWN 9/12/2024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAM BY E R 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8"ABOVE ROOF SURFACE. PV-9.0 SAFETY PLAN 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE SHEET# PV-1 0 ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH PV-10.0 SAFETY PLAN TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0+ SPEC. SHEETS 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: R32 NOT L.1 PATHWAYS: LEGEND - NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON L SEPARATE ROOF PLANES, OF NE FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON PROPERTY LINE �,, W y ALL BUILDINGS. �P RZ A O AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM WITH UTILITY METER l qo p� DRIVEWAY SIDE OF THE ROOF. I FENCE 186' I e '` FOR EACH ROOF PLANE TH A PHOTOVOLTAIC ARRAY,A MINIMUM MSP 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE -- -- —--- ------ " MAIN SERVICE PANEL ------- -'--" * " SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING { r W THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE I �^ a OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS I . 18'-1 0" I SUB SUB PANEL 106793 ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS DRIVEWAY WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR rn I AC DISCONNECT A'Q�FESSIONP� MECHANICAL EQUIPMENT. I R324.6.2 SETBACK AT RIDGE: LU Effl 81'-11" Exp:9/30/2025 COMBINER FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 STAMPED 09/11/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN i W I~ AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A Q 52-9' ch I �B HORIZONTAL RIDGE. JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A O I MODULE WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. /n / %% RENEWABLES ENGINEERING INC. R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS \LUJ \� 23'-7" I ROOF OBSTRUCTIONS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED J ,� THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 44;���__ __�_ __ ____�____�_____ __ ________�_ ROOF ACCESS POINT Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. /I 149'-10" I RenewaWe5 A PATHWAY ON STREET FENCE/GATE PROPERTY LINE Engineering OR DRIVEWAY SIDE OF ROOF B FIRE ACCESS POINT CURRENT RENEWABLES ENGINEERING INC. WISFEAa CHICAGO AVE SUITE 36"ACCESS PATHWAYS J-13,RIVERSIDE CA 92507 PHONE: PHONE:(951)d05-1733 NANW.CRENG.CO 18"ACCESS PATHWAYS CONTRACTOR INFO NOTES: ENLARGE VIEW 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND MEASUREMENTS. [man* 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS EZSYSA INCORPORATED INTO THE 2017 NEC AND UL (N) NON FUSED AC DISCONNECT STANDARD 1741. 3. EXISTING ROOF VENT SHOULD NOT BE (E) UTILITY METER ELEMENT ENERGY LLC. COVERED. 7470 SOUND AVENUE,MATTITUCK, (E)MAIN SERVICE PANEL NEW YORK,11952 NOTE: (N) FUSED AC DISCONNECT PH:(631)779 7993 serREVENUE GRADE KWH PRODUCTION METER Licence- ME-52689 CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 (N) COMBINER Licence-METRICIA ROOF OBSTRUCTION (MASTER ELECTRICIAN) STANDARDS. FA F. Licence-HI-67461 (SUFFOLK HOMEIMPROVEMENT) � SUB W Q c (E)SUB PANEL Solar Individual Permit Package Z O (N) COMBINER JOE CONSTANT[N-GUILD ILD 12.750KW Grid Tied J Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 ev I D.—ption I Date A INITIAL DESIGN 3/23/2024 i UPDATED DESIGN 3/27/2024 5 I UPDATED DESIGN 902/2024 PPORTUNITY JOE CONSTANTIN-GUILD OJECT# NA )ATE DRAWN 9/12/2024 SITE PLAN 36" ROOF ACCESS POINT ROOF LINE HEFT BY ER 1 36"ROOF ACCESS POINT HEET# Pv-zo TLE SCALE: 1/32" = V-O" SITE PLAN ARRAY AREA LEGEND EAVE TO ROOF ROOF TOTAL #OF RIDGE ARRAY AREA AREA AREA AREA 0 NEN,y ROOF ROOF TYPE AZIMUTH DIMENSION ENSION (Sq.Ft.) COVERED BY COVERED BY (Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) UM UTILITY METER h`Oe�R1 A 44 O'p� #1 COMP SHINGLE 132 9 14.58 189.09 2111 8.96 * Q #2 COMP SHINGLE 1 222 6 13.50 126.06 2111 5.97 sP MAIN SERVICE PANEL #3 COMP SHINGLE 42 5 13.50 105.05 1 2111 4.98 29.86 J sus e 793 ? #4 COMP SHINGLE 222 5 8.50 105.05 SUB PANEL C 2111 4.98 � - . � #5 COMP SHINGLE 42 5 8.50 105.05 2111 4.98 106 f� Cv �c AC DISCONNECT �FESSIONP� Exp:9/30/2025 (N)#30 JINKO SOLAR: JKM425N-54HL4-B C� COMBINER STAMPED 09/11/2024 ..)B JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS ROOF#5 MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT ROOF OBSTRUCTIONS RENEWABLES ENGINEERING INC. (N) NON FUSED AC DISCONNECT Current (E) UTILITY METER - (N) FUSED AC DISCONNECT (E)MAIN SERVICE PANEL (Iij- Engineering (N)COMBINER CURRENT RENEWABLES W ROOF#3 ENGINEERING INC. Ac urn ROOF#4 J-13 RIVERSICHICAGDE AVE SUITE J-13,RIVERSIDE CA 92507 Q sus PHONE(951)405-1733 WWW.CRENG.CO z (E)SUB PANEL CONTRACTOR INFO 0 W (N) COMBINERa R 061 J STRUCTURAL NOTES : EZSYSA 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE ELEMENT ENERGY LLC. PROPOSED PV INSTALLATION ONLY. 7470 souNo AVENUE,MATffTllcK, NEW YORK,11952 T-6" 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. PH:(631)779 7993 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS services@e2sys.com Licence-ME-52689 MUST FOLLOW MANUFACTURER GUIDELINES AND (MASTER ELECTRICIAN) REQUIREMENTS. Licence-HI-67461 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL (SUFFOLK HOME IMPROVEMENT) 3' CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. Solar Individual 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR Permit Package ROOF#1 INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE ROOF#2 INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY JOE CONSTANTIN-GUILD INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 12.750KW Grid Tied - ROOF 1:2x10 RAFTERS @ 16" OC SPACING WITH MAX Photovoltaic System UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. - ROOF 2&3: 2x8 RAFTERS @ 16" OC SPACING WITH MAX 400 LEGION AVE, UNSUPPORTED SPAN EQUAL OR LESS THAN 14 FT. MATTITUCK,NY 11952 - ROOF 4&5: 2x4 RAFTERS @ 24" OC SPACING WITH MAX Rev Description Date UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. A INITIAL DESIGN 3/23/2024 A UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 9/12/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 9/1 212 0 2 4 ROOF PLAN DRAWN BY E R 2 SHEET# PV-21 LOF SCALE: 3/32" = V-0" PLAN MAX ROOF ROOF ROOFING FRAMING FRAMING OC PENETRATION MAX NO TILT TYPE ATTACHMENT TYPE TYPE SIZE SPACING PATTERN PENETRATION OV RHANG P' E,OF NEWyO SPACING ��o0�9,5 A. Z4 .per ROOF 1 21 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x10" 16" FULLY STAGGERED 64" n li ROOF 2 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16" FULLY STAGGERED 64" 106 ROOF 3 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16" FULLY STAGGERED 64" 24" �DA�OFESSIONP���c� ROOF 4 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" Exp:9/30/2025 ROOF 5 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" STAMPED 09/11/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables JINKO SOLAR:3KM425N-54HL4-B Engineering CURRENT RENEWABLES IRONRIDGE XR-100 ENGINEERING INC. 1760 CHICAGO AVE SUITE TABLE PENETRATION PHONIVERSIDECA92507 PHONE'(961)-403-1733 GUIDE FOR INSTALL WWW CRENG CO CONTRACTORINFO a (E)COMP SHINGLE TWO OR MORE ROWS OF PANELS 2.5"MIN'EMBED. IRONRIDGE QUICKMOUNT HALO ULTRA GRIP CZSYS. I I I I I I I I I I I I I I I I I I ELEMENT ENERGY LLC. #14 X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING 7470 SOUND AVENUE,MATTrIUCK, RAFTER NEW YORK,11952 PH:(631)779 7993 I I I I I I I I I services@e2sys.com Licence-ME-52689 (E) 2°x1o"/ 2"x8" RAFTER @ 16"O.C. I I I I I I I I I I I I I I I I I I (MASTER eHII-6741 O.C. (SUFFOLK HOME IMPROVE MENT)ENLARGED VIEW 2X4 RAFTER @ 24 STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE XR-100 Permit Package IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ONE ROW OF PANELS JOE CONSTANTIN-GUILD JINKO SOLAR:JKM425N-54HL4-B 12.750KW Grid Tied SEE ENLARGED VIEW I I I I I I I I I I I I I Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 (E)2"X4" RAFTER@ 24" O.C. FULLY STAGGERED STACKED/STAGGERED Rev Desrsiption Date A INITIAL DESIGN 3/23/2024 A UPDATED DESIGN 3/27/2024 AS UPDATED DESIGN 9/12/2024 ATTACHMENTDETAILS (E)COMP SHINGLE OPPORTUNITY J OE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY E.R SHEET# PV-3 0 TITLE STRUCTURAL BACKFEED BREAKER SIZING (SYSTEM#1) BACKFEED FUSE SIZING (SYSTEM 42) MAX. CONTINUOUS OUTPUT 1.33A @ 240V (N)ENPHASE MAX. CONTINUOUS OUTPUT 1.33A @ 240V COMBINER BOX MODEL 13.30 X 1.25 = 16.63AMPS 20A BREAKER-OK NO#X-IQ-AM1-240-5 26.60 X 1.25 = 33.25AMPS 40A FUSES-OK �,-OF NElvy SEE 705.12 OF 2017 NEC rES �P pE,- 0 100 X 1.20 = 120 �Zo `" 120 - 100 = 20A ALLOWABLE BACKFEED MODULE MANUFACTURER 11NKO SOLAR !u G D WSYSTEM #1 MODULE MODEL KM425N-54HL4- 09912E� MODULE(W) 425 �� CTRIGAWG#12,SKU:Q-12-RAW-300.THHN MODULE PTC(W) 398.104 IQ8MC-72-M-US i-#8AWG.EGCTHWN-2 '0r, S,S1 MICROINVERTERS IN 3/4'OR LARGER PVC CONDUIT MODULE ISc(A) 13.58 MODULE Voc(V) 38.95 STAMPED 09/11/2024 BRANCH-1 -------,,C JINKO425N- N MODULE Imp(A) 13.13 HESE DRAWINGS ARE SUBJECT TO SOLAR:JKM425N-54HL4-B L-____- ___-___, MODULE Vmp(V) 32.37 •OPYRIGHT PROTECTION BY US LAW. ----- I EPRODUCTION IN ANY FORM IS - XPRESSLY FORBIDDEN WITHOUT PRIOR RITTEN APPROVAL FROM CURRENT 3-#10 AWG,THWN-2 I 1-#8 EGC,THWN-2 I :E NEWABLES ENGINEERING INC. (E)t00A RATED IN 3/4"OR LARGER PVC I MAIN BREAKER CONDUIT I (END FED) I (E)iSUBP RATED L Current SUB PANEL 1 PH.120/240V 60HZ y (N)ENPHASE I (E)2ODARATED E)UrIL,r Engineering MAIN SERVICE PANEL METER 6 1 COMBINER BOX MODEL I m PH.120124OVMHZ NO#X-I0-AM1-240-5 I %'� R Cj URRENT RENEWABLES T N IDEA/2P BREAKER NGINEERING INC. CELL WIRE LESS I (TOP FED) I60 CHICAGO AVE SUITE SYSTEM #2 MODEM COMMS I '-13.RIVERSIDE CA 92507 IN)2OPV A�RP , ` HONE.(951)-405.1733 IQ GATEWAY I CRENG.CO ('0)I08MC-72-M-US m I CONTRACTOR INFO MICROINVERTERS I Nil 5-/� rFT (N)60A RATED (N)60 A FUSED AC I /j\ ` BRANCH-2 I 40 AC DISCONNECT DISCONNECT L______ e JINKO N m SQUARE D D322NR8 SOLAR.JKM425N-54HL4-B r1 I SQUARE D DU222RB LISTED LI D CON TAP VIA UL I KNIFEBLADE. WITH 40 A FUSES, i-\ __-_--_ N)20A/1� I LOCKABLE,NEMA KNIFEBLADE, LISTED CONNECTOR ..- - /� LOCKABLE,NEMA 3R, IEI 100A/2P ('3)IQ8MC-72-M-US - I I 3R,UL LISTED UL LISTED SUBPANEL BREAKER MICROINVERTERS I (N)20�T I I L_ TO UTILITY C2SYS8 �1 ■I I dI a FEED EAD BRANCH-3 I L------ --- ----- �� ------ -------- ---- '�JWKO N __------ f !J 1 ELEMENT ENERGY LLC. L--___ SOLAR.JKM425N-54HL4-B ♦ r EwsTINGwIaEauN 7470 SOUND AVENUE,MATTITUCK, J I THROUGH CONDUIT I NEW YORK,11952 3-#6 AWG,THWN-2 PH:(631)779 7993 3-#8 AWG,THWN-2 1-#8 EGC,THWN-2 services@e2sys.com I AWG#12,SKU:Q-12-RAW C T THHN I 1-#S EGC,THER P IN 3/4"OR LARGER PVC L-----IR------ IIL 1_88 AWG.EGC THNM-2 J IN 314"OR LARGER PVC - GEC.BARE Licence-ME-52689 IN 3/4'OR LARGER PVC CONDUIT CONDUIT COPPER FREE AIR (E)GROUNDING ELECTRODE (MASTER ELECTRICIAN) CONDUIT BONDED EXISTING UFER TIE IN CONDUCTOR N6 BARE COPPER Licence-HI-67461 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING ADJUSTMENT MAXIMUM 12.750KW Grid Tied STARTING TEMPERATURE AWG CURRENT FACTOR FOR ADJUSTED CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION # EQUIPMENT WIRE LOCATION CITY. WIRE AMPACITY RATING (°C) APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO Photovoltaic System SIZE 310.15(B)(16) CONDUCTORS IN 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS RACEWAY 310.15(B)(3)(a) IN RACEWAY 400 LEGION AVE, 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90e 13.85 0.96 1 28.80 17.31 MATTITUCK,NY 11952 2 AC MICROINVERTER TO COMBINER EXTERIOR WALL 2 12 30 90, 13.30 0.96 1 28.80 16.62 eV Desuiption IDate A INITIAL DESIGN 1 3/23/2024 3 AC COMBINER TO NON FUSED EXTERIOR WALL 3 8 55 90, 26.6 0.96 1 52.8 33.25 Al UPDATED DESIGN 1 3/27/2024 AC DISCONNECT NON FUSED A.5 UPDATED DESIGN 9112/2024 4 AC TO FUSED AC DISCONNECT EXTERIOR WALL 3 8 55 90° 26.6 0.96 1 52.8 33.25 PPORTUNITV I JOE CONSTANTIN-GUILD AC DISCONNECT 5 AC FUSED AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90, 26.6 0.96 1 72 33.25 PROJECT# NA ATE DRAWN 9/12/2024 6 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 RAWN BY ER 7 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.30 0.96 1 28.80 16.62 HEET# PV4.0 TITLE 8 AC COMBINER TO POI EXTERIOR WALL 3 10 40 90e 13.30 0.96 1 38.4 16.62 ELECTRICAL 3LD 1 1 1 BACKFEED BREAKER SIZING (SYSTEM#1) BACKFEED FUSE SIZING (SYSTEM#2) MAX. CONTINUOUS OUTPUT 1.33A @ 240V (N)ENPHASE MAX. CONTINUOUS OUTPUT 1.33A @ 240V 13.30 X 1.25 = 16.63AMPS 20A BREAKER-OK COMBINER BOX MODEL 26.60 X 1.25 = 33.25AMPS 40A FUSES-OK OF NEW M SEE 705.12 OF 2017 NEC NO#X-IQ-AM1-240-5 (�G YO 100 X 1.20 = 120 CELL WIRE LESS �P`IOO� NY/�G MODEM COMMS MODULE MANUFACTURER ANKO SOLAR * h G * 120 - 100 = 20A ALLOWABLE BACKFEED r IQ GATEWAY MODULE MODEL JKM425N-54HL4-13 0 D W SYSTEM #1 m °�"� _ _ N)15A:� MODULE(W) 425 MODULE PTC(W) 398.10 N�OA CTRICP� � O � AWG#12,SKU Q-t2-RAW-3D0.THHN ,�`, MODULE Isc(A) 13.58 R �gS!ONP (1 D)IQBMG72-M-US 1-#B AWG,EGC THWN-2 IN 3/4"OR LARGER PVC CONDUIT MODULE VQc(V) 38.95 MICROINVERTERS /1 STAMPED 09/11/2024 BRANCH-1 IN)20A MODULE Imp(A) 13.13 10 JINKO n MODULE Vmp(V) 32.37 ESE DRAWINGS ARE SUBJECT TO SOLAR:JKM425N-54HL4-B OPYRIGHT PROTECTION BY US LAW. PRODUCTION IN ANY FORM IS XPRESSLY FORBIDDEN WITHOUT PRIOR RITTEN APPROVAL FROM CURRENT 3-tt10 AWG,THWN-2 NEWABLES ENGINEERING INC. 1-#8 EGC,THWN-2 (E)100A RATED IN 3/4"OR LARGER PVC MAIN BREAKER CONDUIT (END FED) (E)100A RATED Current SUB PANEL 1 PH,12(240V 60H2 _ - (N)ENPHASE MAN6E)20DARAATEDL (E)UTLITP Engineering COMBINER BOX MODEL IPH 120/24OV60HZ METER NO#X-IQ-AM1-240-5 'JRRENT RENEWABLES T (E)200A 12P GINEERING INC. I\ MAIN BREAKER SYSTEM #2 CELL WIRE LESS 1 CHICAGO AVE SUITE MODEM 13,RIVERSIDE CA 92507 COMMS P 10NE:(951)�OS-1733 2DAfDEA2R IQ GATEWAY Pv BREAKER WW.CRENG.CO U>IQ6MG7z-M-us -, TT CONTRACTORINFO MICROINVERTERS N)15A1 (N)BOA RATED (N)60 A FUSED AC BRANCH-2 DISCONNECT I 40 AC DISCONNECT r\° SQUARE D D322NR6 1 J JINKO N ,��, SQUARE D DU222RB WITH 40 A FUSES, . . (N)LINESIDE TAP VIA UL SOLAR:JKM425N-54HL4-8 KNIFEBLADE, LISTED CONNECTOR _ N)20:� KNIFEBLADE, LOCKABLE,NEMA LOCKABLE,NEMA 3R (E)1EAXER mum (+3)IQSMG72-M-US 3R,UL LISTED UL LISTED 6UBPANEL BREAKER MICROINVERTERS CZSYS TO UTILITY BRANCH- 0 °�'f a T OVERHEAD 10 JINKO N ° �b FEED ELEMENT ENERGY LLC. SOLAR:J KM425N-54 H L4-B EKI STING WIRERUN 7470 SOUND AVENUE,MATTITUCK, THROUGH CONDUIT NEW YO RK,11952 3-#6 AWG,THWN-2 PH:(631)779 7993 3-#8 AWG,THWN-2 1-#8 EGC,THWN-2 services@e2sys.com AWG#12,SKU 0-12-RAW-IT-, 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC - LARGER EGC CONDUIT I IN 3/4"OR LARGER PVC - Licence-ME-52689 TRICIA L J CONDUIT IN 3/4"OR LARGER PVC CONDUR CONDUIT (E)GROUNDING ELECTRODE (MASTER ELECTRICIAN) CONDUCTOR#5 BARE COPPER Licence-HI-67461 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 718"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANT]N-GUILD STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 12.750KW Grid Tied AWG CURRENT FACTOR FOR ADJUSTED CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO Photovoltaic System # QTY. SIZE AMPA RATING (°C) CONDUCTORS IN FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(1)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY 400 LEGION AVE, 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 MATTITUCK,NY 11952 2 AC MICROINVERTER TO COMBINER EXTERIOR WALL 2 12 30 90° 13.30 0.96 1 28.80 16.62 Yev Description Date INITIAL DESIGN 3/2 312 0 2 4 3 AC COMBINER TO NON FUSED EXTERIOR WALL 3 8 55 90° 26.6 0.96 1 52.8 33.25 1 UPDATED DESIGN 3/2712024 AC DISCONNECT 5 UPDATED DESIGN 91122024 4 AC NON FUSED TO FUSED AC DISCONNECT EXTERIOR WALL 3 8 55 90° 26.6 0.96 1 52.8 33.25 AC DISCONNECT PPORTUNITY IOE CONSTANTIN-GUILD OJECT# NA S AC FUSED AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90` 26.6 0.96 1 72 33.25 TE DRAWN 9112/2024 6 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 <RAWN BY ER 7 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.30 0.96 1 28.80 16.62 HEET# PV-5.0 TILE 8 AC COMBINER TO POI EXTERIOR WALL 3 10 40 90° 13.30 0.96 1 38.4 16.62 ELECTRICAL SLD MATERIAL LIST FNE ELECTRICAL EQUIPMENTS ,r,P OE MANj �.p QTY. PART TYPE PART NUMBER DESCRIPTION * ~� °G� � D W 30 MODULE CS6R-40OMS-HL CANADIAN SOLAR CS6R-40OMS-HL y 099128 30 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US ��oA << 2 COMBINER X-IQ-AM1-240-5/5C ENPHASE COMBINER BOX X-IQ-AM1-240-5/5C R°�SSAdtJP 1 NON FUSED AC DISCONNECT DU222RB 60A RATED 240VAC NEMA 3R UL LISTED STAMPED 09/11/2024 1 FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED ESE DRAWINGS ARE SUBJECT TO C)PYRIGHT PROTECTION BY US LAW. PRODUCTION IN ANY FORM IS 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS E:PRESSLY FORBIDDEN WITHOUT PRIOR /RITTEN APPROVAL FROM CURRENT R:NEWABLES ENGINEERING INC. Current Renewables Engineering C IRRENT RENEWABLES GINEERING INC. 17 A CHICAGO AVE SUITE -'3.RIVERSIDE CA 92507 j;_;p P ON (951)<OS-1733 NW.CRENG.CO CONTRACTOR INFO BREAKER / FUSES QTY. PART TYPE PART NUMBER DESCRIPTION mum 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) —..- 1 FUSES 40A FUSES GENERAL40A FUSES CZSYSA 1 PV BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 C If I (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168A XR100, RAIL 168" BLACK Permit Package 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 JOE CONSTANTIN-GUILD 42 CLAMPS & GROUNDING UFO-CL-01-Al UNIVERSAL MODULE CLAMP, BLACK KW Grid Tied 36 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL Photovoltaic System 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 400 LEGION AVE, 84 ATTACHMENTS QM-HUG-01-M1 HALO ULTRAGRIP, MILL MATTITUCK,NY 11952 84 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev Description Date A INITIAL DESIGN 3/2 312024 84 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE A.1 UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 1 9/12/2024 OPPORTUNITY JOE CONSTANTM-GUILD PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY E.R SHEET# PV_60 TITLE BOM OF NEW r\P E MA/y/ O,Q PHOTOVOLTAIC SYSTEM, w EQUIPPED ' 1 1• y oss,za CTRICP�' U' 690.12 A�O�SSIONP� STAMPED 09/11/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR TURN RAPID PV SYSTEM AC DISCONNECT WRITTEN APPROVAL FROM CURRENT SHUTDOWN SWITCH TO RATED OUTPUT CURRENT ■ RENEWABLE$ENGINEERING INC. THE "OFF" POSITION TO AC AC NORMALOPERATING • 1 VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current Renewables AND REDUCE SHOCK "WARNING" Engineering HAZARD IN THE ARRAY 690.56(C)(1)(B) DUAL POWER • ■CES ENGINEERING CCURRENT ABLES SECOND SOURCE PHOTO- VOLTAIC 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 RATED OUTPUT CURRENT ■ 39.90 • ■ ♦ 1 � � � PHONE.(951)-405-1733 r WWW.CRENG.CO AC NORMAL OPERATING VOLTAGE - 240 VOLTS CONTRACTORINFO 690.54 OPTIONAL SOLAR LOAD CENTER a a ARRAY CZSYSs ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, JAB NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 ♦ ■ L (MASTER ELECTRICIAN) Licence-HI-67461 INVERTER OUTPUT • • (SUFFOLK HOME IMPROVEMENT) 1• NOT RELOCATE THIS NEC 690.31(G)(3)&(4),CRC R324.7 Solar Individual OVERCURRENT DEVICE Permit Package (UNLESS BUSBAR IS FULLY RATED) `- — 705.12(D)(2) PHOTOVOLTAIC POWER • ■ JOE CONSTANTIN-GUILD EVERY 10'ON CONDUITAND ENCLOSURES 12.750KW Grid Tied Photovoltaic System NOTES. 400 LEGION AVE, MATTITUCK,NY 11952 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. Rev Description Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 3/232024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR Al UPDATED DESIGN 3/27/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. A UPDATED DESIGN 9/12/2024 B. RED BACKGROUND COLOR WHITE TEXT AND LINE OPPORTUNITY OE CONSTANTIN-GUILD WORK. PROJECT# NA C. AERIAL FONT. DATE DRAWN 9/12/2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# Pv- o HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. � -OF NEFW �P OBE MA/yj� 0 * 4u cZ r— D W m099128w Zip�O � crR1cP`' � SSIdNP�' CAUTION STAMPED 09/11/2024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current -wabies Engineering PV ARRAY CURRENT RENEWABLES ENGINEERING INC. W 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 Q PHONE.(951)-405-1733 COMBINER Z W W W CRENG CO O CONTRACTORINFO Hl 0 SUB PANEL LLJ J COMBINER im® m MAIN SERVICE PANEL FUSED AC DISCONNECT •• CZSYS9 UTILITY METER ELEMENT ENERGY LLC. NON FUSED AC DISCONNECT 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL JOE CONSTANTIN-GUILD PANEL IS AC DISCONNECT PER NEC690.17 12.750KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description I Date A INITIAL DESIGN 1 312312024 A.1 UPDATED DESIGN 3/27/2024 A.5 UPDATED DESIGN 1 9/12/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY E.R SHEET# PV-7.1 TITLE PLACARD 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 MICROINVERTER CHART 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current 4b Renewable.- Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG.CO CONTRACTORINFO 5 a EM EZSYSA ELEMENT ENERGY LLC. 6 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.750KW Grid Tied 8 Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 9 A UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 9/12/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY ER 1 O SHEET# PV-8 0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS: El COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. Ac REPRODUCTION B ANY FORM IS AC DISCONNECT EXPRESSLYFORBIDDEN WITHOUT PRIOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN MSP MAIN SERVICE PANEL RENEWABLES ENGINEERING INC . 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET �M UTILITY METER Current IN CASE OF EMERGENCY O Renewables P PERMANENT ANCHOR = Engineering NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC JB JUNCTION BOX CURRENT RENEWABLES NAME: I TO ENGINEERING TEMPORARY ANCHOR CHICAO AVE INC.1ITE ADDRESS: J-13 RIVERSIDE CA92507 IL INSTALLER LADDER PWWW CRENG C01733 F SAFETY COACH CONTACT INFORMATION STUB-OUT CONTRACTOR INFO NAME: Li ADDRESS:— ® SKYLIGHT NO LADDER ACCESS (STEEP GRADE ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE OR GROUND LEVEL OBSTRUCTIONS) CZSYS0 SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR ❑ WORKING SAFELY. RESTRICTED ACCESS ELEMENT ENERGY LLC. CONDUIT 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 NAME SIGNATURE GAS GAS SHUT OFF PH:(631)779 7993 services@e2sys.com Licence-ME-52689 20 WATER SHUT OFF (MASTER ELECTRICIAN) Licence-HI-67461 OSERVICE DROP (SUFFOLK HOME IMPROVEMENT) O POWER LINES Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.750KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 DATE TIME: A 1 UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 9/1 212 0 2 4 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY ER SHEET# PV-9 0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel,and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all The site supervisor shall forecast the weather conditions at the Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations. Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below). If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure.Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with COPYRIGHT PROTECTION S LAW. REPRODUCTION IN ANY FORM IS S uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT prior to work start,at midday and prior to solar panel ensure all employees have access at an point. RENEWABLES ENGINEERING INC. Extension ladders must be used with walk-through devices or falling objects. rooftop)p y p the ladder must extend 36"above the stepping off point. Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. Elevated work involving the moving or maneuvering of solar If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall Cease at 25mph(sustained wind)until wind Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure leaned against a structure). Workers. Forecasted weather maximum temp(degrees F): Contact your Site Supervisor 01n • Additional notes: Crew leader responsible for communication with the client: Engineering Name: Mobile Equipment Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment;operators must Yes, No): Heat Related Illness Prevention Phone: CURRENT R G INC. LES maintain a certification on their person for the equipment being Employees shall have access to potable drinking water that is ENGINEERING INC. P 9 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13,RIVERSIDE CA92507 • Type(s)of mobile equipment(Type/Make/Model): All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE:(951)-405-1733 WWW.CRENG.GO hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift. Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: Im ig n • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees Cz SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: u • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete;a fall rescue plan must be outlined and • Crew member(name/title): New employees must be acclimatized. New employees will be of what happen and when. 7470 SOUND AVENUE,MATTITUCK. discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and connect • Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift. Employees must take Licence-ME-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-HI-67461 • Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACM-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed • Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an JOE CONSTANTIN-GUILD electrically safe condition(de-energized)unless approval has If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 12.75OKW Grid Tied • Service drops and overhead electrical hazards will be • If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: indentified and protected from contact as neccessa water(location/address): Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 400 LEGION AVE, MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 323/2024 A.1 UPDATED DESIGN 3/27/2024 A.5 UPDATED DESIGN 9/12/2024 OPPORTUNITY JDE CONSTANTIN GUILD PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN www.jinkosolar.com JinK0_ &Wding Your Trust it Solar Current-Voltage t Power-Voltage Teeperature Dependence a. Isc,Voc,Pass Tiger Neo N—type _ C °f9 i415R' me 54R4—B _ - - w u m t I.n THESE DRAWINGS ARE SUBJECT TO - + - a•e me COPYRIGHT PROTECTION BY US LAW. 425 Watt _ f'• �m i REPRODUCTION IN ANY FORM IS a—.-- •�d y °a 1 EXPRESSLY FORBIDDEN WITHOUT PRIOR .m ! r I WRITTEN APPROVAL FROM CURRENT � • RE NEWABLES ENGINEERING INC ALL—BLACK MODULEIJ i I N-Type a p rm Current Yolv�r(Y•. Gtl Tgvamre L� Positive power tolerance of 0— 3% n ~ Engineering IEC61215(2016), IEC61730(2016) CURRENT RENEWABLES 1509001:2015: Qual itr Management System -T """t ENGINEERING INC. IS014001:2015: Environment ron nagement ys'- t Ya 5 eon � 1 1760 CHICAGO AVE SUITE y •� Ir�^�!' ueisa.zr lA<;i Typr '•type Yana-cnstnl!inr p I 111SSJJJJ I 'i. a s_y J 13,RIVERSIDE- 92507 15045001:2018 PHONE:(951)-4051733 a I Occupational health and safety management systems na Dimensions 1722x 1134 x,ttmm (67.79x44-6.Sx 1.18 inrhl WWW.CRENG.CO CONTRACTORINFO Key Features L FronT Glass 3.2a•.Ant sci Retied ion('namting. — ransmit on. LowIroa ampered Glass wo pe!teta=One st•d High T ) luatttw so. IP68 Rated Alm no SMBB Technology *mein Hot 2.0 Technology _ FQ Better light trapping and current eolleetion to improve i_j The N-type module.ith Hot 2.0 technology has better E2SYSA module primer output and reliability. 2.0 reliability and lower LIWIETID. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 lbduie TYce 19M29i 5�B 4-g PH:(631)779 7993 services@e2sys.com PID Resistance Enhanced Mechanical Load Licence-ME-52689 ® a 44 Luellent Anti-PID performance guarantee vie - Q (MASTER ELECTRICIAN) Pe g Certified to withstand: wind load (2400 Pascal) and sons Ytuirr Po►cr (Pro) L.Sllp 320Yp optimized mass production process and materials ;,° load (y400 Paaall Licence-HI-67461(SUFFOLK HOME IMPROVEMENT) Yaximm Power Current (Imp) 13.13A 10.60A Solar Individual Short.-rircait Current "an) 13.W 10.%A Permit Package ® Durability Against Extreme Environmental sm ®• Conditions troerats re Ta.peratatY( t) +DC-��C JOE CONSTANTIN-GUILD High sal, mist and ammonia resistance_ Yazi--series fuse rating 25A 12.750KW Grid Tied Photovoltaic System Temperature coefficients of Paaa '0.2%,/°C LINEAR PERFORMANCE WARRANTY _ 400 , N AVE, Temperature coefficients of)sc 0.045%`C MATTITUCKCK NY 11952 Rev Description 43'20 pk R!R A INITIAL DESIGN E25 Year Product Wa rranty y •�. A UPDATED DESIGN JTC:# I irradiance 100(�Y.'m Cel l Temperature 25' C � AY=1.5 A.5 UPDATED DESIGN 30 Year Linear Power Warranty NOCT: 7�c Irradiance B00N m Ambient Temperature 20� C $01 AM-1.5 Rind Speed Im,'s OPPORTUNIT OE CONSTANTIN G PROJECT# NA WAS DATE DRAWN 9/1 212 0 2 4 E Nomm '—, 0. 40% Annual Degradation Oyer 30 years DRAWN BY ER 1 An C2021 Jinko Solar Co., Ltd. All rights reserved. a Specifications included in this datasheet are subject to change without notice. JKM425N-54HL4-B-F3C2-&N (IEC 2016) SHEET tt Pv-1to TITLE MODULE SPEC !n ENPHASE. ® IQ8MC Microinverter INPUT DATA DC] UNITS 108MC-72-M-US Commonly used module pairings w 260-460 Module compatibility _ To meet compatibility.PV modules must be within the following max.Input DC voltage and max.module I-. Module compatibility can be checked at nttps-/,, tpfasa.com/installers/mlcrcnvertws/calcWatw. MPPT voltage range V 25-45 THESE DRAWINGS ARE SUBJECT TO Operating range V 16-58 COPYRIGHT PROTECTION BY US LAW. Min./Max.start voltage v 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Max-input DC voltage v 60 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max.module) A 20 Current �j Overvoltage class DC port - II , .. j ble S DC port backfead current mA O Engineering PV array configuration - Ungrounded array:no additional DC side protection required;AC side protection requires max 20 A per branch circuit CURRENT RENEWABLES ENGINEERING INC. Peak output power VA 330 315 1760 CHICAGO AVE SUITE Q8 M C Microinverter Easy to install PH RIVERSIDE-1 92507 Max.continuous output power ya 320 370 PHONE: 951 405-1733 Lightweight and compact with plug-and-play Nominal grid voltage(L-L) V 240.split-phase(L-L),IW 208.single-phase(L-L).120` W W W CRENG.CO Our newest 108 Series Microinverters are the industry's first mierogrid-forming•,software- connectors CONTRACTOR INFO defined microinverters with split-phase power conversion capability to convert DC power to Min./Max.grid voltage V 211-264 183-229 AC power efficiently.The brain of the semiconductor-based microinverter LS our proprietary Power line communication(PLC)between Max.continuous Output current A 1.33 1.49 application-specific integrated circuit(ASIC).which enables the microinverter to operate In components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with smple two-wrre Nomina:frequency NZ 60 digital logic and has superfast response times to changing bads and grid events.alleviating cabling Extended frequency range Nz 47-68 constraints on battery sizing for home energy systems. AC short circuit fault current over three Arms 2.70 HGgh productivity and reiabifity cycles CZ SYS4 .- Produces power even when the grid is down• Max.units per 20 A(L-L)branch circuit 12 10 • More than one million cumulative hours of Total harmonic distortion <5 ELEMENT ENERGY LLC. testing 7470 SOUND AVENUE.MATTITUCK, Class II do +n uble- sulated enclosure Overvoltage class YORK,11952ass AC port - it PH:(631)779 7993 Part of the Enphase Energy System, IQ8 Series Microinverters redefine - Optimized for the latest high-powered PV AC port backfeed current mA 18 services@e2sys.com -52689 IQ8 Series Microinverters integrate with reliability standards with more than oils modules _ Licence-ME ELECTRICIAN) ty Power factor setting to the IQ Battery,10 Gateway,and the million cumulative hours of power-on (MASTER ELECTRICIAN) Enphase App monitoring and analysis testing,enabling an industry-leading Mlicrogtid-forming Grid-tied power factor(adjustable) - 0.85 leading...0.85lagging Licence-HI-67461 software. limited warranty of up to 25 years. Peak efficient % 97.4 972 (SUFFOLK HOME IMPROVEMENT) • CorrplrAss with the latest advanced grid Y support CEC weighted efficiency % 97.0 96.5 • Remote automatic updates for the latest grid Solar Individual ` Nighttime power consumption mW 33 25 requirements Permit Package • Configurable to support a wide range of grid profiles Ambient temperature range -40°C to 65"C(-WF to 149'F) JOE CONSTANTIN-GUILD Meets CA Rule 21(UL 1741-SA)and Relative humidity range 4%to 100%(condensing) Connect PV modules quickly and easily 108 Series Microinverters are UL Listed IEEE 15472018(UL T741-SB) to the 108 Series Microinverters that have as PV rapid shutdown equipment and DC connector type StaubliMC4 12.750KW Grid Tied integrated MC4 Connectors. conforms with various regulations when wart. Dimensions(H"W"D):Weight 212 mm(8.3")"175 in.(6.9")•30.2 min(1.2"):1.1 kg(2.43lbs) Photovoltaic System installed according to the manufacturer's • KMMic7omveners carrot be—ad together with Coding Natural convection-no fans instructions. previous gen ratmns of Enphaea micro(nverters 1107 trim.106 Series and ae on).m the same Approved for wet locations;Pollution degree Yes:PD3 400 LEGION AVE, system. Enclosure Clam 11 double-insulated.corrosion-resistant polymeric enclosure MATTITUCK,NY 11952 10 Microirwertes sMp with default settings that meet North America's IEEE 1547 interconnection Environ.category:UV exposure rating NEMA Type 6:outdoor standard regmremems Ragmn pecmc Rev Description Date adjusunints may be requested by an Authority A INITIAL DESIGN 3/23/2024 Having jurisdiction(AHJ)or utility representatrve. An 10 Gateway rs regoaed to mate these changes CA Rule 21(UL 1741-SA).UL 62109-1.IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class G.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01. A UPDATED DESIGN 3127/2024 'Meets UL 174t Doty when irsstalled with ro system Controller 2 w 3 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017.NEC 2020,and NEC 2023 section 690.12 and durmgantallatan. P ap xaq P A UPDATED DESIGN 9/1212024 C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. OPPORTUNITY )OE CONSTANTIN-GUILD se G 2024 Enpha Energy.All rights reserved.Enphaae.the a and CC logos.IQ and tartan otter marks listed at .__ (17 No enforced DC/AC ratio. M.kgs/(gnpnaze.com�:rpeemar k-u_ e-cu�oeli=e_are hidirmarks of Enphaae Energy.Inc.in the US and other coumnes. (2)Nominal whage range oar be extended beyond nominal If required by the utility. PROJECT# NA Data subject to change. IOBMC 4AC4-DSH-00049-4D-EN-(1S-2024-02-09 (3)Limits may vary.Rafe,to local requirements to define the number of microinrrtars pot branch m your area. 10aMC-MC4-OSH-00049-4.0-EN-US-2024-02-09 DATE DRAWN 9/12/2024 DRAWN BY ER SHEET# PV-11.1 TITLE MICROINVERTER SPEC l \ \ N I \ X X X X X X X Y N Y Y X Y Y Y `<' Y Y Y Y y Y-,,<-Y ENPHASE. ® IQ Combiner 5/5C .01 MODEL NUMBER IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV 10 Combiner 5(X-I0-AMt-240-5) production metering(ANSI C12.20±0.5%),consumption monitoring(±2.5%).and IQ Battery monitoring(±2.5%).Includes a silver solar shield to deflect heat. ENPHASE IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade IQ Combiner SC(X IQ-AM1 240-SC) PV production metering(ANSI C1220±0.5%),consumption monitoring(±2.5%).and IQ Battery monitoring(±2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-Mt-06-SP-05)'.Includes a silver solar shield to deflect heat. WHAT'S IN THE BOX ESE DRAWINGS ARE SUBJECT TO PYRIGHT PROTECTION BY US LAW. IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive.remote -PRODUCTION IN ANY FORM IS maintenance.and management of the Enphase Energy System .PRESSLY FORBIDDEN WITHOUT PRIOR 'RITTEN APPROVAL FROM CURRENT Busbar 80 A busbar with support for one IQ Gateway breaker and four 20 A breakers for NEWABLES ENGINEERING INC. installing 10 Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker.2-pole,10 A/15 A X-10-AM7-240-5 Production CT Pre-wired revenue-grade solid-core CT.accurate up to±0.5% Current R X-10-AMl-240-5C Consumption CT Two consumption metering clamp CTs,shipped with the box.accurate up to±2.5% '`e,.`. `r a b1es IQ Battery CT One battery metering clamp CT.shipped with the box,accurate up to±2.5% Engineering CTRL board Control board for wired communication with IQ System Controller 3/3G and the J�IGINEIERING RENT RENEWABLES IQ Combiner 5/5C IQ Battery 5P INC. 4G-based LTE-Ml cellular modem(CELLMODEM-Mt-06-SP-05)with a 5-year T-Mobile IVERSICHICAG AVE s2507ITE Smart Enphase Mobile Connect(only with IQ Combiner SC) IVERSIDE CA 92507The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and data plan E'(951)-405-1733 streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent. Includes IQ Gateway for CRENG co pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control communication and control Accessories kit Spare control headers for the COMMS KIT-2 board communication and is compatible with IQ System Controller 3/3G and 10 Battery 5P. Includes Enphase Mobile Connect ACCESSORIES AND REPLACEMENT PARTS INOTINCLUDED, •r CONTRACTOR INFO (CELLMODEM-MI-06-SP-05),only The IQ Combiner 5/5C,10 Series Microinverters.10 System Controller 3/3G,and with IQ Combiner 5C CELLMODEM-MI-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan IQ Battery 5P provide a complete grid-agnostic Enphase Energy System. • Supports flexible networking:Wi-Fi. CELLMODEM-Mt-06-AT-05 4G-based LTE-Mt cellular modem with a 5-year AT&T data plan Ethernet•or cellular Supports Eaton BR2XX.Siemens Q2XX,and GE/ABB THQL2IXX Series circuit breakers Provides production metering Circuit breakers(off-the-shelf) (XX represents 10,15.20,30,40,50.or 60).Also supports Eaton BR220B,BR230B.and Cc SYS (revenue grade)and consumption BR240B circuit breakers compatible with the fold-down kit. monitoring / Circuit breakers(provided by Enphase) BRK-10A-2-240V,BRK-15A-2-24OV,BRK-20A-2P-24OV.BRK-15A-2P-24OV-8,and / BRK-20A-2P-24OV-B(more details in the-Accessories"section) ELEMENT ENERGY LLC. 6 Easy to install 7470 SOUND AVENUE,MATTI UCK, XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C NEW YORK,11952 Y IQ Series Microinverters 10 System controller 3/3G • Mounts to one stud with centered 99 7 779 3 The high-powered smart grid-ready IQ Series Provides microgrid interconnection device brackets XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board(PCB)for IQ Combiner 5/5C PH:(63services1)1)779 .c 3 Microinverters(I06,107,and I08 Series) (MID)functionality by automatically detecting om Supports bottom,back,and side X-I0-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws) Licence-ME-52689 simplify the installation process. grid failures and seamlessly traroitioning conduit entries (MASTER ELECTRICIAN) the home energy system from grid power to XA-COMMS2-PCBA-5 Replacement COMMS-KIT-2 printed circuit board(PCB)for 10 Combiner 5/5C Licence-HI-67461 backup power. Supports up to four 2-poie branch (SUFFOLK HOME IMPROVEMENT) circuits for 240 VAC plug-in breakers ELECTRICAL SPECIFICATIONS ' (not included) Rating BOA Y 80 A total PV branch circuits Solar Individual System voltage and frequency 120/240 VAC or 120/208 VAC.60 Hz Y Permit Package Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Busbar rating 125 A Fault current rating 10 WC JOE CONSTANTIN-GUILD Y Reliable Maximum continuous current rating 10 Battery 5P 10 Load Controller Durable NRTL-certified NEMA type 3R (input from PV/storage) 64 A 12.750KW Grid Tied Full integrated AC batter system.Includes Hel s prioritize essential appliances during a enclosure y � y y p p � g Up to four 2-pole Eaton BR,Siemens Q.or GE/ABB THQL Series distributed generation Photovoltaic System six field-replaceable 108D-BAT Microinverters. grid outage to optimize energy consumption 5-year limited warranty Branch circuits(solar and/or storage) (DG)breakers only(not included) 3 and prolong battery fife. 2-year labor reimbursement program 400 LEGION AVE, Y coverage included for both the Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IQ Gateway breaker included MATTITUCK,NY 11952 ❑ IQ Combiner SKUs' IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included v Y NOM ` UL1741 Listed Production metering CT 200 A solid core pre installed and wired to IQ Gateway Description Date INITIAL DESIGN 3/23/2D24 0 � Consumption monitoring CT(CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box 1 UPDATED DESIGN 3/27/2024 IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering,included with the box UPDATED DESIGN 9/1 212 02 4 Y 5-year limited warranty PORTUNITY IOE CONSTANTIN-GUILD Y P OJECT# NA Y 'For country-specific warranty information.see the httrw.//eMFage com/msWkwa/resources/warranty page. m D E DRAVM 9/12/2024 A plug-end-play irdustrlel-grade cell otlem for systems of up to BO mlcrdver ntera.Available In the United Stales.Canada,Mexico.Puerto Rico,and the US Virgin Islands.where there Is adequate O 2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain o1Mr narks listed at cellular service in the Installation area. D WIN BY E.R Y Mp.//enphss.com/trademark-usage-awtlelines aretrademarks of Enphsaa E—gy,krc inthe LLS and~countries. ET# PV-11.2 Y Data subject to change. IOC-5-5C-DSH-00007-5.0-EN-US-2024-0B-16 IOC-5-5C-DSH-00007-5.0-EN-US-2024-08-16 LE Y COMBINER y SPEC /fir IRONRIDGE XR Rail`a' Family XR Rail0 Family The XR Rail," Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads,while minimizing material costs. Depending on your location,there is an XR Rails to match. Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years. owl- THESE DRAWINGS ARE SUBJECT TO but the worst storms in 40 years. High winds capable Of ��`�,,. _ _ _ - COPYRIGHT PROTECTION BY US LAW. ripping panels from a roof, and snowfalls weighing i REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR enough to buckle a panel frame. _ WRITTEN APPROVAL FROM CURRENT RE NE WABLES ENGINEERING INC. XR Rails R are the structural backbone XR10 XR100 XR1000 preventing these results.They resist uplift, protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and Commercial XR1000 is a heavyweight among Current and efficiently transfer loads into the rail,designed for regions with light or mounting rail It supports a range of solar mounting rails It's built to handle _ :Ibles buildingt Their superior no snow It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 structure. r while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. Engineering spanning capability requires fewer roof attachments. reducing the 6'spanning capability 10'spanning capability - 12'spanning capability CURRENT RENEWABLES number of roof penetrations Moderate load capability Heavy load capability Extreme bad capability ENGINEERING INC. p Clear&black anodized finish Clear&black anodized finish Clear anodized finish 1760 CHICAGO AVE SUITE and the amount of Internal splices available Internal splices available Internals splices available p J-13,RIVERSIDE CA 92507 installation time. PHONE:(951)405.1733 W W W.CRENG CO Rail Selection CONTRACTOR INFO t The table below was prepared in compliance with applicable engineering codes and standards.'Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount. Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. EZSYS Snow(PSF) Wind(MPH)- -- �� ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTfTUCK, Force-Stabil-Izing Curve 90 NEW YORK,11952 7993 Sloped roofs generate both vertical and lateral PH:(631)779 s.co forces on mounting rails which can cause them to Non120 Licence- ME-52689 bend and twist The curved shape of XR RaiIS9 � 140 XR10 XR100 Licence-ME ELECTRICIAN) is specially designed to increase strength in both (MASTER ELECTRICIAN) Chrections while resisting the twisting.This unique Licence-HI-67461 feature ensures greater security during extreme 160 (SUFFOLK HOME IMPROVEMENT) weather and a longer system lifetime 90 12o Solar Individual 20 Permit Package \ 140 JOE CONSTANTIN-GUILD 160 90 12.750KW Grid Tied 30 160 _ Photovoltaic System Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 400 LEGION AVE, XR Raile are lronPklge�otters All XR Rails'^are made of 6000-senes i 40 MATTITUCK,NY 11952 Compatible with a range of tiff leg aluminum alloy.then protected with an 160 FlashFooY°and options for flat anodized finish Anodizing prevents surface Rev Description Date A other pitched roof roof mounting and structural corrosion,while also providing 80 160 A INITIAL DESIGN 3232D24 attachments. applications. a more attractive appearance. 120 160 AA UPDATED DESIGN 3272D24 - A UPDATED DESIGN 91122024 Table is rneant to be a simplified span Chart for corweyft general rail capabilities.Use approved certification letters for actual Design guidance. OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA 0 2023 lronRidge,Inc.All rights reserved.Visit-iromidge.com,or call ;rimore DATE DRANK 9/122024 DRAWN BY E.R SHEET# PV-11.3 TITLE RAI L SPEC IRONRIDGE QuickMount° Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home.solar attachments • • `� THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. • , i��J COPYRIGHT PROTECTION BY US LAW Due to recent innovations. many asphalt shingles REPRODUCTION IN ANY FORM IS P g — - R EXPRESSLY FORBIDDEN WITHOUT PRIOR have bonded COUfS2S.A mount that protects without - WRITTEN APPROVAL FROM CURRENT the need to pry shingles can really speed things up. • • • ! RENEWABLES ENGINEERING INC Halo UltraGrip (HUG`) is here to respect the roof. Its Halo is a cast-aluminum barrier that encases the Current UltraGrip.our industrial-grade.foam-and-mastic _ Rene' seal.This allows HUG to accelerate the installation Engineering process and provide the utmost in waterproofing Hit the rafter? ... to go! Miss the rafter?Try it protection. Give your root a HUG. again. screwsmore han 3 CURRENT RENEWABLES neededWhen you find a rafter,you can move n. Place another screw to the left or right.If Oniv 2 RD Structural Screws are � •_ mount it. ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE(951)-405-1733 WWW.CRENG.CO uTiered Waterproofing HUG HUG utilizes a multi-tiered stack of CONTRACTOR INFO cortiponents to provide revolutionary Trusted Strength & Less Hassle Waterproofing protection.The Halo cast- raised-perimeter foundation fheUltraGhp base—a foam- Structural capacities of HUG` were reviewed in �qy� mastic seal combination that many load directions.with racking rail running ® n meter intrusion by adhering ••— with the shingle surfacecross-slope or up-slope in relation to roof pitch- with z SYS9. For further details. see the HUG certification of the letters for attaching to rafters and decking. ELEMENT ENERGY LLC. prOC�` 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 -- - IronRidge designed the HUG. in combination PH:(631)779 7993 URraGrip` Seal Technology with the RD Structural Screw to streamline services@e2sys.com HUG UnraGnp utilizes a state-of- installs, which means the following: Licence-ME-52689 art Seal design that uses a unique. (MASTER ELECTRICIAN) foam-and-mash combination.The Licence-HI-67461 foam-backed adhesive provides an ' No prying shingles (SUFFOLK HOME IMPROVEMENT) entirely new flashing system that No roof nail interference conforms and adheres to every nook 25-Year Warranty NO ilot holes necessar and cranny of composition shingles, �,'.,, ( Pro-,I,c'? a,ant.�e."1-ee p y Solar Individual tilling gaps and shingle step-downs - of-Mpd,r,ny reiec,=s No sealant(in most cases) Permit Package (up to 1/8'in height) No butyl shims needed JOE CONSTANTIN-GUILD Attachment Structural Water Seal UL 2703 12.750KW Grid Tied Loading Design Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG`-to the roof ratters.the roof e Section mecan cal Rev Descnpl,on Date HUG has been and certified for the UL 441 Sti UL 2703 hi deck.or both with our custom-engineered � I A INITIAL DESIGN 3123/2024 RD(rafter-or-deck)Structural Screw.The RD tested and rated to i compliance with 27"Rain Test"and and bonding Triple Rated&Certified A.1 UPDATED DESIGN 3/27/202a P � Structural Screw anchors HUG to the root support 1004(Ibs)of I the International TAS 100(A)-95 requirements. See to Respect the Root" /� with an EPDM sealin9 P 9 washer.coin letm A 5 UPDATED DESIGN 9/12/2024 G. UL 2703.441(27) the stack of waterproofing barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual OPPORTUNITY I lOE CO NSTANTIN-GUILD k tek TAS 1OO(A)-95 backside for more installation information. Of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. 1PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY E.R �- - nc.Allrightsreserved. www. on. r SHEET# PV-11 4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. 28357 Industrial Blvd. I RON RI DGE Hayward.CA 94545 Hayward CA Hayward.CA 94545 1-800-227-9 IronRidge.com IRONRIDGE IronRidge om3 Attn:Sean McDonald,CEO,IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following Date:November 16".2022 Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1. 2. Winds speed shall conform to ASCE 7-16 Fig 26.5-1 B for Risk Category II and applicable state&local THESE DRAWINGS ARE SUBJECT TO P 9 ( 9 Y ) PP COPYRIGHT PROTECTION BY US LAW. This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The county/city amendments to the IBC No special wind topographic features are included and both topographic REPRODUCTION IN ANY FORM IS contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(Kr,)and wind ground elevation factor(KE)are taken as 1.0. EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape RENEWABLES ENGINEERING INC orientation and set parallel to the underlying roof surface PV modules are supported by extruded aluminum XR Rails 3- Snow load used in the span tables is the ground snow and shall conform to ASCE specified edFig now and applicable state&local county/city amendments to the IBC- If the local jurisdiction specified snow load is in the and secured to the rails with IronRidge mounting clamps The XR Rails are side mounted to a selected roof format of a flat roof snow,it shall first be converted to a ground snow following the local building code/ attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables. No special snow conditions are considered Current that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced.drifting,sliding, retention,or ponding snow. No rain-on-snow surcharge load is cl) Re components are shown in Exhibit EX-0015. considered The span tables do not apply to buildings which are intentionally kept below freezing,keptjust Enalneering above freezing or unheated The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being CURRENT RENEWABLES listed below for the load conditions and configurations tabulated in the attached span tables ENGINEERING 1760 CHICAGO AVE SUITE (a)For ground snow no greater than 42psf.Ss<2 Og for Site Class A, B,C.&D. J-13 RIVERSIDE CA 92507 • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Ss<_1.Og for Site Class A. B,C,&D. PHONE WWW CRENG CO 1733 • 2021 International Building Code(IBC-2021) (c)For ground snow between 42 and 65psf:Ss<_1_5g for Site Class A, B,C. &D. CONTRACTOR INFO • 2022 California Building Code(CBC-2022) • 2020 Aluminum Design Manual(ADM-2020) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in (Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCa). Roof zones comprising each group along • Report Sminu with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length..measured from the rail end to the nearest attachment point-shall respective load EZS provided for the res n bl p p YS� ll f th 40%dit o e allowable spa t ll f f th le sser esser o e following two conditions the respective loads and configurations listed. covering wind exposure categories 8,C, &D. roof zones provided in be I u ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8`to 45' The tabulated spans are applicable when the &configuration condition from the span tables. or 36" following conditions are met 7 Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over ELEMENT ENERGY LLC. a minimum of three spans 7470 SOUND AVENUE,MATTMJCK, NEW YORK.11952 1. Span is the distance between two adjacent roof attachment points(measured at the center of the PH:(631)779 7993 attachment fastener). 8. No splices are allowed in the rail cantilever.For each XR splice type install per the following requirements: services@e2sys.com Licence-ME-52689 a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2/3 of end spans. (MASTER ELECTRICIAN) 2- Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system) Spans are calculated b) BOSS Splice can be installed at any location within a span. Licence-HI-67461 based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. (SUFFOLK HOME IMPROVEMENT) 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If 3. The underlying roof slope. measured between the roof surface and horizontal plane,is 8°to 45 such conditions are encountered contact techsuppod@ironridge com. Solar Individual Permit Package 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from grade,does not exceed 30 feet. JOE CONSTANTIN-GUILD 5. A clearance from the underside of the array to the roof surface of 2'minimum shall be provided and the 12.750KW Grid Tied height of the array the distance from the module top surface to the roof surface(defined as h2).shall not Photovoltaic System exceed 10". 400 LEGION AVE, 6. Module length and area shall not exceed the maximum values listed on the respective span tables. MATTITUCK,NY 11952 Rev 7, All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush A INITIAL IAL DESIGN Date 3/23/2024 Mount Installation Manual and other applicable standards for the general roof construction practice Al UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 911212024 OPPORTUNITY I IOECONSTANTIN-GUILD T 2022 IronRidge Inc CA Flush Mount System Certification Letter-1 r.2022 IronR,dge.Inc. CA Flush Mount System Certification Letter-2 PROJECT# NA DATE DRAWN 9/12/2024 DRAWN BY E.R SHEET# PV-11 5 TITLE CERTIFICATION Preliminary Technical !r CanadianSolar Information Sheet HiKu6 (All-Black) ALL BLACK MONO PERC 380 W - 405 W CS6R-380 1 385 1 390 1 395 1 400 1 405MS-HL MORE POWER 25 Industry Leading Product Warranty on Materials Years and Workmanship* 405OWModule power up to 405 W �-•-.,, 405 W Module efficiency up to 20.7% l t 25 Linear Power Performance Warranty* Years Lower LCOE&system cost 1"year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% *Subject to the terms and condmons contained,n the applicable Canadian Solar Limited warranty Statement.Also Mrs 25-year limited product warranty is available only for prod- Comprehensive LID/LeTI D mitigation ucts installed and operating on residential rooftops in certain regwns. technology,up to 50%lower degradation ...... ._..... _. . .. .... ....._.. ...................... MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015/Quality management system Q Better shading tolerance ISO 14001:20151 Standards for environmental management system ISO 45001:20181 International standards for occupational health&safety PRODUCT CERTIFICATES* MORE RELIABLE 11C 61215/IEC 61730/CE J INMETRO UL 617301 IEC 61701/IEC 62716 Take-e-way Minimizes micro-crack t im acs 11p�., pV1 ■ LJ p _ c�t.sC f % *The specific certircates applicable to different module types and markets will vary, and therefore not all of the certifications'fisted herein will simultaneously apply to the Heavy snow load up to 7000 Pa, products you order or use.Please contact your local Canadian Solar sales representative wind load up to 5000 Pa* to confirm.the speufK certificates available for your Product and applicable in the regwns in which the products will be used. ..........I.................. ....................................................... ...................... CSI SOLAR(USA)CO.,LTD.is committed to providing high quality solar photovoltaic modules,solar energy and battery storage Solutions;to customers.The company was recognized as the No.1 module supplier for quality and performancelprice ratio in the IHS Module Customer Insight •Pending testing confirmation.For detailed information. Survey.Over the past 20 years,it has successfully delivered over 67 GW please refer to the Installation Manual of premium-quality solar modules across the world. CS]SOLAR(USA)CO.,LTD. 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597, USA I www.csisolar.com/na I service.ca@csisolar.com ENGINEERING DRAWING(mm) CS6R-400MS I-V CURVES A A Rear View Frame Cross Section A-A 14 --14 13 A-A 12 -12-- 10 -,a------- �41V Hole TI k9 84 7 M�bng Hole ----------------- 3 3 2 2- --------------- - ---------- -- I --- -- T Mounting Hole J 1*4 S 10 I5 20 25 X 35 40 45 50 55 60 5 10 15 20 25 30 35 40 45 SO 55 W ■ 1 000 wini, 5-c ■ ■ wo win,, 25'C ■ 600W- 45'c ■ ■ 400 w1rW 65-C ■ ILIA 200 w/m, ELECTRICAL DATA STC- MECHANICAL DATA CS6R 380MS 385MS 39OMS 395MS 40OMS 405MS Specification Data Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp)30.0V 30.2V 30.4V 30.6V 30.8V 31.0 V Cell Arrangement 108[2 X(9 X 6)] Opt.Operating Current(Imp)12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A 1722 x 1134 x 35 mm Open Circuit Voltage(Voc) 36.0 V 36.2 V 36. Dimensions 4 V 36.6 V 36.8 V 37.0 V (67.8 x 44.6 x 1.38in) Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 21.3 kg(47.0 lbs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti- Operating Temperature -40*C-+85*C reflective coating Max.System Voltage 1500V(IEC/UQ or 1000V 0EC/UQ Frame Anodized aluminium alloy, J-Box IP68,3 bypass diodes Module Fire Performance TYPE 1(UL 61730 150OV)or TYPE 2(UL 61730 Cable 4 mm'(IEC),12 AWG(UL) 1 OOOV)or CLASS C(IEC 61730) Max.Series Fuse Rating 25A Connector T6 or MC4 series Application Classification Class A Cable Length 1550 mm(61.0 in)(+) Power Tolerance 0-10W (Including Connector) 850 mm(33.5 in)(-)* *Under Standard Test Conditions(STC)of irradiance of 1000 W/rrv,spectrum AM 1.5 and cell tempe- Per Pallet 30 pieces rature of 25*C- Per Container(40'HQ) 780 pieces -For detailed information,please contact your local Canadian Solar sales and technical representatives ELECTRICAL DATA I NMOT* CS611 38OMS 385MS 390MS 395MS 40OMS 405ms TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data Opt.Operating Voltage(Vmp)28.1 V 283V 28AV 28.6V 28.8V 29.0V Temperature Coefficient(Pmax) -0.34%/*C Opt.Operating Current(Imp)10-12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A --- Temperature Coefficient(Voc) -0.26%1*C Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/*C Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A*Under Nominal Module operating Temperature(NMOT),irradiance ofOW W/rrii-spectrum AM 1.5, Nominal Module Operating Temperature 42>t 3"C ambient temperature 2(rC.vend speed 1 m/s. PARTNER SECTION The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovaboin and product enhancement.CS1 Solar Co..Ltd.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using ng our PV modules. CSI SOLAR(USA)CO.,LTD. June 2022 1 All rights reserved PV Module Product Datasheet v1.5C25_F23j2_NA ENPHASE CMMM 1 Q 8 and I Q 8} Microinverters Easy to VauA Our newest!Da Wicroir rsr?ers are the r dustrj's first microgritt-`arming,sof wars- igixt arC Lampsct wirth defined microinverters with sofrt-phase pourer conversior"abWrty to corvert DC ping-r-piay correctors poyver to AC power efficierrt:;y.?he brain of L+le semiconductor-vase,✓microinvar±sr yref ireicari?cr.- is our proprietary appiicatior-specific ir:tecrated circuit WlCi which enables use microinverter too (PLC"ovweer components Renate in grid-tied or off-yrd rnoe'es. ...rs chip is boil#in�+ranee 55nm technology witi^High speed digital logic and has super-fast response tsmes =aster ,mstailiatior,willh_*noe to changing±pads and grid events,alleviating constraints on batter/siring,cr rorr+e t'ac-'Mws oacorg energy systErns. Hkjii Pfoducttv*y and raiabii;t, - M'SeLce--ewer s-)er IYr?er`'re gid is dowr l Worell',an crie.*rAftr-_-mulavvs _ 'SC W 9 r..`�tBStiltCj Cass'F ftubie-insUated Part of the Enphase energy System,IC8 Series r_8 Serres.Wcromverters redefine reliability ?±?aiOsuf3 ,A'icrcmverters integrate with the Enphase A Batter, standards with more than one million cumulative Enphase iQ Gateway,and the Enphase �Gt rRiZtd are j2f33t"iCP- prlas App monitcrirtg hours of power-art testing,enabling an industry- and analysis software. leading!imited Marranty of up to 25 years. PJWered Pl/m. odwe8 MCTOgId*W111iIv Ccrnpiies°Aftn the sates? acvarcec grid support" Remote aLtomadic mates for the latest grid requirements Connect PV modules quickly and easily to I08 Series IQ8 Series Microinverters are UL Listed as Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down E --o�urable to support-a Mde daft p Equipment and conform with cable with plug-n-play MC4 connectors. carious regulations,when installed according to range of grid;profiles manufacturer's instructions. -Wets CA Rule 77'UL 1741-Sat) requirements m 2022 Enphase Energy.All rights reser,ed.Enphase,the Enphase logo,I08 Mcroinverters,and other 'Only when' nstalled with 10 System Controller 2. names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. '•IQ8 and IQBPIus supports split phase,240V lQ8SP-OS-0002-01-EN-US-2022-03-17 installations only. IQ8 and IQ8+ Microinverters Commonly.,sed module pairings Al 235-350 235-44C Module compatibility 80 cell/120 halt-cell 60-ceil/12C half-cell.66-cell/132 half-cell and 72-cell/144 halt-cell MPPT voltage range v 27-37 29-45 Operating range v 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage v 50 60 Max DC current"[module isc] A 15 Overvoltage class DC port 11 DC port backfeed current MA 0 PV array ccrfguration ix1 Ungrounded array.No additional DC side protection required;AC side protecticr regwres max 2CA per branch circuit OUTPUT DATA(ACI MPLUS-72-2-US Peak output power VA 245 3CC Max continuous output power VA 24C 29C Nominal(L-L)voitage/range' v 240/211-264 Max continuous output currert A Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit" 16 13 Total harmonic distortion <5% OvPrvnitage rJass AC pert III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -40cC to+60OC(-40cF to+14COF) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm MY)x 175 mm(6.9')x 302 mm(121 Weight 1.08 kg(2.381bs) Coding Natural convection-no fans Approved for wet locations yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Erviren.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-20118 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at httpsJ/lirk.erphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range car be extended beyond nominal if required by the itility.(4;Limits may vary.Refer to;coal requiremerts to defire the rumber cf micrcirverters per branch,r.your area. 108SP-OS-0002-01-EN-US-2022-03-17 IRONRIDGE Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested � PE Certified QAll components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Hating Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty UO Entire system and components meet Twice the protection offered by newest effective UI_2703 standard. competitors. XR10 Rail XR100 Dail XR1000 Rail Bonded S;pNces is A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • S'spanning capability 8'spanJfinish • 12'spanning capability • Self-drilling screws • Moderate load capability Heavy l • Extreme load capability • Varying versions for rails • Clear and black finish • Clear a • Clear anodized finish • Forms secure bonding UFOs ��- Stopper Sleeves Grounding Lugs Microinverter Kilts 9 �v Universal Fastening Objects Snap onto the UFO to turn ys to Mount Mis or FOs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled &tubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 Flash Foot2 Conduit Mount Slog=mkt BerxNn g Hardware mik Flash and mount XR Rails Flas d mount conduit, - esign for rapid rail Bond and attach XR Rails with superior waterproofing. _,stybt, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases insfail • Twist-on Cap eases install Secure rail connections T& Square Bolt options • Wind-driven rain tested • Wnd-driven rain tested • Slot for vertical adjusting Nut uses 7/16"socket Mill and black finish • Secures 3/a"or 1"conduit • Clear and black finish • Assembled and lubricated Design Assistant NABCEP Certified Training Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems.