Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51127-Z
S11ff0 Town of Southold ao� oo� 10/9/2024 0 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45641 Date: 10/9/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 1640 Calves Neck Rd, Southold SCTM#: 473889 Sec/Block/Lot: 70.4-39.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/16/2024 pursuant to which Building Permit No. 51127 dated 8/29/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Martin,Liam&Lisa of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 51127 7/8/2024 PLUMBERS CERTIFICATION DATED A hor' d Signature ofsa�ryo`o TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE umv. SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51127 Date: 08/28/2024 Permission is hereby granted to: Liam Martin PO BOX 165 Orient, NY To: install generator as applied for. Premises Located at: 1640 Calves Neck Rd,Southold, NY 11971 Section\Block\Lot#70.-4-39.1 Pursuant to application dated 07/16/2024 and approved by the Building Inspector. To expire on 02/27/2026. Contractors: Required Inspections: Fees: ACCESSORY $125.00 ELECTRIC-NEW CONSTRUCTION $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total 325.00 Building Inspector oF so�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(c-town.southold.ny.us Southold,NY 11971-0959 COUNT` i BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Liam Martin Address: 1640 Calves Neck Rd city,Southold st: NY zip: 11971 Building Permit#: 51 127 Section: 70 Block: 4 Lot: 39.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Peconic Power Systems License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 26kW Generac Generator w/200A Whole House Transfer Switch Notes: Generator 2q Inspector Signature: Date: July 8, 2024 1640 Calves Neck Electrical hO�aOF SOUTyO� # TOWN OF SOUTHOLD BUILDING DEPT. Couto, 631-765-1802 �- INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]- SULATIONG [ ] FRAMING /STRAPPING [ FINAL &A= [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ : ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: DATE INSPECTO Q41f so TOWN OF SOUTHOLD BUILDING DEPT. ,roum" 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: le tj /V J DATE 2 INSPECTOR ` FIELD INSPECTION REPORT DATE COMMENTS � b r FOUNDATION (1ST) ------------------------------------- FOUNDATION (2ND) 67 ' r z S C ' ^y ROUGH FRAMING& PLUMBING (p z 'c J - ray C r � INSULATION PER N.Y. y STATE ENERGY CODE r J FINAL ADDITIONAL COMMENTS 2 °l �- o r Z rm y O z x � d b y TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 y Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownnv.go Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D PERMIT NO. Building Inspector: �DD J U L 1 6 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Ow n"er's Authorization form(Page 2)shall be completed. BUMDING DEFT. T 11 OWN -)F SOUTH0 Date: OWNER(S)OF PROPERTY: Name: SCTM# 1000- Project Address:t(OLIC) CANYeS t\)OaXb&N &59-k�- \\J Y k Phone#: Email: Mailing Address: ( ((Oqo A)&A CONTACT PERSON: Name: Mailing Address: S\-'sr S ��A Y, 3-o Phone#: 51 Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: llV�� 0A of�'eYA Phone#: c31.1 CONTRACTOR INFORMATION: Name: t Mailing Address: .R66 S-L)(A "'K() A \Nk/ Phone#: 1; Email- DESCRIPTION OF PROPOSED CONSTRUCTION E]NewStructure DAddition EAlteration ORepair DDemolition Estimated Cost of Project: $ VD,0 Will the lot be re-graded? E]Yes*No Will excess fill be removed from premises? E]Yes .43No PROPERTY INFORMATION Existing use of property: Intended use of property: - - - 1(knu— - - - --- - -- -.-__ - - - Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes RNo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections:False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By( t n ): v�'f I gAuthorized Agent El Owner Signature of Applicant: Date: 1 / CONNIE D.BUNCH - STATE OF NEW YORK) Notary Public,State of New York No,01BU6185060 S1 aualified in Suffolk County q�-��c/ COUNTY OF b\� ) Commission Expires April 14,2� ZS 4� —I,, -,ltelLe being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the C Yd-C✓-6y (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this bq+�day of � � 20,Aq Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at (¢�b ��eS � 11i0�i N/ do hereby authorize � to apply on my behalf to the Town of Southold Building Department for approval as described erei . //Own "s Signature ate Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector �4 G TOWN OF SOUTHOLD }a„ A N z d Town Hall Annex- 54375 Main Road PO Box 1179 r, Southold, New York 11971-0959 4, ao1 , Telephone (631) 765-1802 - FAX (631) 765-9502 ia mesh(ab-southoldtownny.gov - seand(a)-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: S' Z Company Name: QCd t(- � s Electrician's Nameld2A slahoi\,CA, License No.: ME-- HS05-C Elec. email: Elec. Phone No:.Sj�-30-�/21 ❑1 request an email copy of Certifi ate of Compliance Elec. Address.: 315 CbM p &) C� v2 / - JOB SITE INFORMATION (All Information Required) Name: I A aytALi S a. Address: Cross Street: v Phone No.: Bldg.Permit email: �, C Tax Map District: 1000- Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: © YES ❑ NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New service[:]Fire Reconnect[-]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M1 2 D H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION d.Copyright 2023,Alphonse Pesca Jr,Co.,Inc.land Surveying,All Rights Reserved. 2.Unaubmicad alteration or addition to a survey map bearing a licensed lard surveyces seal is a violation of section 7209,subdivision 2,of the New York State Education Law. 3.Only boundary survey maps with the curveyors and tced seal are genuine We and coned copies of the surveyors original work and opinion. 4.Certifications on Eris boundary survey map signify that the map was prepared in eawrda cewith the cu rehl existing Code of Practice for Land Surveys adopted by the New Yak State Association of Professional Laid Surveyors,Inc.The certification is limited to persons for whom the boundary survey map is prepared,to the tide aanparry,to the governmental agency,and to the lending institution fisted on this bo ndary curvey map. 5.The certifications herein are not transferable. 6.The location of underground improvements or encroachments are not always known and often must be estimated.If any underground improvements or encroachments exist or we shown,the improvements or onaaachmenls are not covered by this certi6sate. 7.The offsets or dimensions shown from the foundation to the property fines are for specific purpose and use and therefore are not intended to guide the erection of fences,retaining Wells,pods,planting areas, addition to structures and any other construction. px— � E 5 �. L I2 ?"2woo^E W to r 0: a o C STORY 14.V o iwo� a 19.9 HIGH 46.r Z 1 STORY tSTORY FRAME DWELLING gar 50.8' C 3,ORY Le x nr. 64.4' ra,�w G Neu TAX / eb LOT 98.1 C) � a d r W W G? t?T 14. tp S50®22'00"yy� — �- Fein y m NOTES: Non4sible easements,recorded or unremded ere not shown. -Underground foundations a substructures nolvisihle are rot shown. SURVEY FOR LOCATION: 1640 CALVES NECK ROAD kgngp pgrP� Jr. TOWN OF SOUTHOLD '( COUNTY OF SUFFOLK STATE OF NEW YORK Omfessfonal i+lanD OurveVor �ti e P W yp9 MAP OF DESCRIBED PROPERTY boa °F O 9 N.Y.S.Uc.No.048365 DIST.:1000 SEC.:70 BLOCK.4 LOT:39.1 O SURVEY DATE:OCTOBER 5,2023 JOB:23-442 5 CIRCLEDALE LANE "�y 048386 HOLBROOK,NEW YORK 11741 sF0 LAND`'JP ®=30' 718-486-5408 631-585-5317 \ �V V r AP ROVED AS NOTED DATE• B.P.it FEES ,Y) BY: NOTIFY BUILDING DEPARTMENT AT 631-765.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUM.BING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR ELECTRICAL DESIGN OR CONSTRUCTON ERRORS INSPECTION REQUIRED COMPLY ALL CODES NEW YORK STATE&TOWN C DFES AS REQUIRED AND CONDITIONS OF SOMLD WN ZBA SOUTHO OWN PLANNING BOARD $OUTH TOWN TRUSTEES N.Y EC OLD HPC HD OCCUPANCYOR USE IS UNLAWFUL WITHOUT CERTIFICA- OF OCCUPANCY GENERAC® GUARDIAN® SERIES 26 k� Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating INCLUDES: G007290-0,G007291-0(Aluminum-Bisque)-26'kW 60 Hz • True Power'"Electrical Technology • Two-line multilingual digital LCD Evolution'"controller(English/Spanish/French/Portuguese) • 200 amp service•rated transfer`switch available' • Electronic governor �— O • Standard Wi-FiO connectivity. �r I • System status&maintenance interval LED indicators 4 Sound attenuated enclosure �- • Flexible fuel line connector _ •1 t"nRkT-�� • Natural gas or LP gas operation GENERAC' „— • 5 Year limited warranty • Base fascia • .-Listed and labeled for installation as close as 18 in(457,mm)to a structure.* O *Must be located awayfrom doors,windows,and fresh air intakes and in accordance with local codes. c E1V 1 • C u�DS `Note:CETL orCUL certification onlyap lies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are EFL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are-at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success,in providing.the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace•of.mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions, loads to the engine.Digital voltage regulation at_0% O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O _SINGLE SOURCE SERVICE RESPONSE from Generac'z extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. 0 , TEST CRITERIA: O._..GENERAC TRANSFER SWITCHES:Long life and reliability.are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with.select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smarlphone,tablet,or PC.Easily access information such as the current operating status'and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. �IGENERAC PROMISE smngg 'AmE110Y161vg1@mleLb;V f G'E N EA46' 26.kW Feature's.and.Benefits- Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and,'plasma molt' rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls • Rigid construction and added durability provide long engine life. • "Electronic ignition/spark advance These features combine to assure smooth,quick starting every time.' • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damag ng voltage spikes. • UL 2200 listed For your safety. ' Transfer.Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized sou{ce of power. • NEMA 3R' Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient Tower management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution" Controls_ W"AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at- glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons• Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay. Prevents nuisance start-ups of the engine,adjusts le 2-1500 seconds from the factory default setting of 5 seconds byi'q oil ified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. 4 Engine cool-down Allows'engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal`drying and;damage between power outages by running the�generator for 5 inihutes every other week.Also offers a selectable setting for'weekly'or monthly operation providing flexibility and potentially lower fuel costs to the owner. ` • Smart battery charger Delivers charge to the battery only when needed of varying,rates depending on outdoor air temperature., Compatible with lead acid and AGM-sfyie bakeries.' • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency, Unit :. • SAE weather protective enclosure Sound'attenuated enclosures ebsute'quiet operation and protection against mother nature; withstanding wind's up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to,prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457.mm)away from a structure. • GENERAC® 26 kW- Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line,connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for ' complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view with battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC®. 26 kW 9 Specifications Generator VI Model G007290-0 G007291-0 _ (2618� Rated maximum continuous power capacity(LP) 26,(26 Rated maximum continuous power capacity(NG) 22,500 Wafts` Ratedvoltage 240 Rated maximum continuous load current-240 volts(LP/NG) I 108.3/93.8, Total Harmonic Distortion i— Less than 5% Main line circuit breaker { 110 amp Phase 1 — Number of rotor poles 2 Rated AC frequency s 60 Hz Power factor 1.0 Battery requirement(not included) 12 Vo_It_s,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 8/235 Dimensions(LxWxH)in/cm 48x25x29/518/235 63.5x73.7 —� Sound output in dB(A)at 23 it(7 m)with generator operating at normal load"" 67 Sound output in dB(A)at 23 ft(7 m)with generator in Quiet-Test"low-speed exercise mode— 57 Exercise duration j 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement { 999 cc Cylinder block t Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system —�—Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter !I{ 12 VDC Oil capacity including filter Approx.19 qt/1.8 L Operating rpm ---�J� 3,600 Fuel consumption Natural gas ft3/h /1/2 Load { 188(5.32) Full Load 333(9.43) Liquid propane fO/hr(gal/hr)[Uhr]1/2 Load 75(2.06)[7.78] Full Load 132(3.63)[13.731 Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,1O-12 in water column(2.49-2.99 kPa)for LP gas. For BfU content,multiply fta/hrx 2500(LP)or fta/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD llSimple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. F—OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages y Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds { Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning { Standard RunlAlarm/Maintenance logs _ 50 events each i Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out T Starter cannot re-engage until 5 sec after engine has stopped. Smart Baftery.Charger Standard Charger Faulumissing AC warning Standard Low Battery/Baftery Problem Protection and Battery Condition indication J Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Ovedoad/StepperOvercurrent Protection { Standard Safety Fused/Fuse Problem Protection Standard' Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Lass Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability J Standard Field upgradable firmware Standard ^� Rating definitions-Optional Standby:Applicable for supplying backup power forthe duration of the utility power outage with correct maintenance performed. "No overload capability is available for this rating.(All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3;5%for each 1,000 ft(304.8 m)above sea level and approximately 1% for each 10 IF(6°C)above 60 IF(16°C)."'Sound levels are taken from the front of the generator.Sound levels taken from other sides ofi the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergency applications g N 9 GENERAC® 26 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007291-0(26 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. No.of poles 2 �� Current rating(amps) '200 • Up to eight additional large(240 VAC)loads can be managed when used in corijuricuun Voltage rating(VAC) 120/240.10 with Smart Management Modules(SMMs). ' ' ' - . •Utility voltage monitor(fixed)* • Electrically operated,mechanically-held contacts for fast;clean connections.. -Pick-rrp„ 80% -Dropout, 65% • Main breakers are rated for 80%continuous load. Return to Utility* Approx.13 sec • 2-pole,'250 VAC contactors. ETL or UL IWO Standard • Service equipment rated,.,dual coil design. Enclosure type NEMAtUL 313 • Rated for both aluminum,and copper conductors. Circuit breaker protected "'22,000 - Lug range 250 MCM-#6 .Main contacts are silver plated,or,silver alloy to resist welding and sticking. r *Function of Evolution controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting fleAbility: Exercise can be set to weekly,bi-weekly,or monthly Dimensions 200 Amps 120/240;.1a , Open Transition Service Rated Height ., Width H1 H2 -' W1 W2 Depth„ _ e, . in 26.8 30.1 10.5 13.5 6.9 cm 67.95• 76.43 26.67 34.18' 17.5 1 Wire Ranges Conductor Lug Neutral Lug ., Ground Lug,,•, 250 MCM-#6 350 MCM-#6. 2/0 #14, o �"�—� GENERAL 26, kW-". Available Accessories Model# Product Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). - lE G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs.' ' G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well,as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit .If the generator enclosure is scratched or damaged,it is important to touch up the paint to'protect from future corrosion. The touch-up paint kit includes the necessary paint-to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a - Generac automatic standby generator(oil not included). . a G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to;run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery,when°overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. " G007169-0-4G LTE Mobile Link'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby_generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and:insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. �i Dimensions & UPCs Model UPC n] aao W G007290-0 696471087307 i G007291-0 696471087314 I 727.2 mm r26.6 In] i I 0 I a O 0 i e46 mm h 1432 mm 0.6 In] [46.61m LEFT SIDE VIEW y FRONTVIEW Dimensions shown are approximate.See installation manual for exact dimension's.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. i i J� i I it GENE RAC® Generac Power Systems,Inc. - S45 W291290 HWY.59,Waukesha,WI 53189 - generac.com ©2022 Generac Power Systems,Inc.Al rights reserved.Al specifications ara�subject to change without notice. Part No.A0002026894 Rev.0 04/26/2022 III 1 II GENERAC ° Automatic Transfer Switches Service and non-Service,rated Automatic Smart Transfer Switches - 100 400 Amps, Single Phase Y a C �L us ®. LISTED `PUL only applies to non-service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an EvolutionT"' or Nexus TM Controller.The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non-service equipment rated configurations.The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an'aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint.The Heavy,Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands.All switches are covered by a 5 year limited warranty. " Non-service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. GENERAC® ' GE N E,RAC® j10.0=4 WORM - Singlo"Phase Automatic Smart',Transfer SwrrtcW Functions 1;. All timing and sensing functions originate in the generator controller Utility voltage drop-out.....:................ .... ......................................................................... �.. . • .....<65% ............10 second facto set,adjustable between 2-1500 sec ................. ............ ...............;...,.................�....... . Timer`to generator start..:......................................................`......:.................... factory j � onds.by`a,qualified dealer"` Engine warm up delay................................................................................................................ . ,.. ......::5:seconds ............................................1.... ..... • Standby voltage sensor............................................................................................................................................................:::............. ...................65%for 5 seconds• . ..; Utility voltage pickup.................. >80% Re-transfer time delay'................:....:.::......::....:......:.....:..........:..:...............................................................................................:....,.' . :............:.15'seconds............. ...... . _ Enginecool-down timer............................................................................................................................................................................................................60 seconds Exercjse'r..................................................:............................:.....:.......................................................................5 or 12 minutes adjustable weekly/Bi-weekly/Monthly** The transfer switch can be operated manually without power applied. 'When used in conjunction with units utilizing Evolution-controls —Adjustable via the controller Specifications Model RXSC100A3 `RXSW100A3" RXSW150A3 RXSC200A3 RXSW200A3'' 'RXSW300A3 RXSC40OA3 RXSW400A3 Amps 100 100 150 - 200 200 300 400 400 Voltage 120/240,1e 120/240,to 120/240,1e 120/240,1m 1201N0,1e 120/240,to 120/240,ie 120/240,to Load Transition Type Open Transition Open Transition Open Transition Open Transition Open Transition Open Transition Open Transition Open Transition (Automatic) Service Rated Service Rated Service,Rated Service Rated Service Rated Enclosure Type NEMA/UL 3R NEMA/UL 311 NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R• NEMA/UL 311 NEMA/UL 313 NEMA/UL 3R UL Rating UUCUL UL UL UUCUL UL UL UUCUL UL Withstand Rating (Amps) 10,000 1 10,000 1 22,000 1 10,000 1 22,000 22,000 1 22,000 22,000 Lug Range ;. 1/0-#14 250 MCM-#6 -600 MCM-#4 or 1/0-250 MCM w, H2 H1 Model RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW30bA3 RXSC400A3 RXSW400A3 H1 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42.91/1089.9 31.25J793.8 42.91/1089.9 Height ; oEarH ,3" wz (inJmm) H2 20/508 20/508 30/762 20/508 301762,; 48/1219.2 36/914.4, ;48/1219.2 W1 W1 12.5/317.5 12.51317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 '16'69/'423.9 Width ;1 ' (inJmm) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2' Depth(inJmm) 7.09/180.1 7.09/180.1 6.3/160.1 -7.09/180.1, 6.3/160.1 10.06/255.5 _10.06/255.5 10.06/255.5 H2 Ht, Weight(lbslkilos) 20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 DEPTH W2 GEN ERAC Generac Power Systems;Inc.' N5•W29290 HWY 59 Waukesha,WI 53189 • generac.com ©2017 Generac Power Systems;Inc. All rights reserved:'All specifications are subject to change without notice.Bulletin 10000013459-A 04/24/17