Loading...
HomeMy WebLinkAbout50735-Z �gHFFDL,f�OG ti Town of Southold 10/4/2024 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45618 Date: 10/4/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 80 Soundview Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 100.4-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated r 4/15/2024 pursuant to which Building Permit No. 50735 dated 5/23/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Kouvaras,George&Elizabeth of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50735 9/20/2024 PLUMBERS CERTIFICATION DATED Aut orize Sign o�SUF Ic TOWN OF SOUTHOLD ha oy BUILDING DEPARTMENT N z ' TOWN CLERK'S OFFICE "oy • o��� SOUTHOLD, NY col aav, BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50735 Date: 5/23/2024 Permission is hereby granted to: Kouvaras, George 29 Sunnyvale Rd Port Washington, NY 11050 To: install generator as applied for. s At premises located at: 80 Soundview Ave, Mattituck SCTM #473889 Sec/Block/Lot# 100.-1-1 Pursuant to application dated 4/16/2024 and approved by the Building Inspector. To expire on 11/22/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector SOUTyoI Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 sean;devlin(a�town.southold.ny.us OM- BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: George Kouvaras Address: 80 Soundview Ave city:Mattituck st: NY zip: 11952 Building Permit* 50735 Section: 100 Block: 1 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Instone Electric License No: 66421 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 24kW Generac Generator w/ (2)150a Transfer Switches Notes: Generator Inspector Signature: Date: September 20, 2024 S.Devlin-Cert Electrical Compliance Form Copy OE SOUIy�� TOWN OF SOUTHOLD BUILDING DEPT. courm►�'�' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND _ [ ] IN ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [. ] FIRE SAFETY INSPECTION [ .] "FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] .ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Q C. ir Ga l o c o. a,s i" - DATE '? INSPECTOR pF SO(/lyOlo 0—7 V # * TOWN-OF SOUTHOLD BUILDING DEPT. coum,N 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION -FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ . ] PRE C/O [ ] RENTAL REMARKS: � � DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS r n FOUNDATION(IST) H ------------------------------------ C FOUNDATION(2ND) z QO o H ROUGH FRAMING& G PLUMBING (V I � r INSULATION PER N.Y. STATE ENERGY CODE G •aAAAI A C,1eQ,e ,zces FINAL ADDITIONAL COMMENTS z m q� H � O z x r� H x C trJ H =��g11FFUL��oGy2 TOWN OF SOUTHOLD—BUILDING DEPARTMENT H x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.izov w.= " Date Received APPLICATION FOR BUILDING PERMIT ,w, r For Office Use Only 4Y- PERMIT NO. ��`� Building Inspector: ti .i pR 2024 Applications and forms must be filled out in their entirety.incomplete applications will not be accepted. Where the Applicant is not the owner;any :Owner's Authorization form(Page 2)shall be completed.. Date: IS 12,q OWNER(S).OF.PROPERTY:. Name: SCTM#1000- �,.7���C.rOU�!►/�/�{ASS Project Address Phone#: Email: )1LoU Jac AQ V-Grn CcnSuk c cw Mailing Address: CONTACT PERSON: Name:Brooke Epperson Mailing Address:PO Box 1 52, Mattituck, NY 11952 Phone#:631 603 9092 Email:bepperson@amparchitect.com DESIGN PROFESSIONAL INFORMATION: Name:Anthony Portillo� _ Mailing Address:PO Box 152,,Mattituck, N.Y. 11952 Phone#:631 603 9092 Email:aportillo@amparchitect.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION'" ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: _Other $. Z ooc� Will the lot be re-graded? ❑YesgNo -- Will excess fill be removed from premises? ❑Yes gNo 1 1 FOR ATIOR. 'y 960W Existing use of.property:Q, n Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to ... this property? E]Yes No IF YES,PROVIDE A COPY. 6�16knkriltdri nage4an,i d" Md'r,,199uiias:p6iv "t''did 506 1W , "', I pil4s vp ".4 4 R. E Y,, P*rt 46f �v -A . .1 . I . .. t ,'8 k MA -'014kt �.tq sqa ik�I- '..'- .,. I k#A bont 6t'e, n .0­1L.Ions Pottion,otbu rbin''P.�t",on pr' 210.45 f th. L Application Submitted By(print name). IWARuthicirlized Agent Downer Signature of Applicant Date: STATE OF NEWYORK) SS: COUNTYOF ��Dlf-�D&/**- _being duly sworn, deposes and says that(s)heis the applicant (Name of indivirual signing contract)above named, (S)he is the (Contra c4oYAgent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her k,nowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 202H Al A No#C�-, ic 6 jkaE AUPENANGER, NOTARY RA3LjC 5TATE OF NEW YOR ANGER NOTARY 0 F NEW YOR 0 �y r Regis;`PROPERTY OWNER AUTHORIZATION Regis 1UU 019644 Q NO-01AU001 9644 OU t Qualified in 5LQQdk County (Where the applicant is not the owner) Co i Commission�--'Yhnuary 9,2028 residing at go SoLk V\a\j Av PIV\Lke, MCAL AUK Lk, gy, kkqS-qdo hereby authorize q M P A ,,\teck— to apply on my behalf to the T wn of Sout old Building Department for approval as descr&T rein. 7. sS ignature Date Q1 "� 11 3 0 r-�e kawio ra) Hint Owner's Name 2 SCENE ,D SEP 1 7 2024 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD �j�,� G�� ' Town Hall Annex-54375 Main Road-PO Box t C)F S®M®U`' _ Southold, New York 11971-0959 Telephone(631)765-1802-FAX(631)765-9502 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Au information Required) Date: Company Name: 1 NS\o t E �-7 -e Co V Electrician's Name: Sh Av CN S o License No.: 1-kE Elec. email: Cope. S•ko C%e et N c'�c-�c. .►J e Elec. Phone No: g%(,, E26 request an email copy of Certificate of Compliance Elec. Address.: ckck Lk mac'v-%\,n cVk�e U X, Wi 3 5 JOB SITE INFORMATION (Ail information Required) Name: Geo.c 2, koov R S Address: gO S00i) v ►eQ \)e. nvi�ttkoc- Cross Street: Phone No.: (oyCo 3Ll . -11-tGO BIdg.Permit#: 63:3& email: �Acsco�lle Ha�,cb� Tax Map District: 1000 Section: 100 Block: I Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): a4K C3e. i�C0C square Footage: Circle All That Apply: Is job ready for inspection?: dYES❑NO Rough In dFinai Do you need a Temp Certificate?: F1 YES gNO Issued On Temp lnformatlon: (All Information required) Service Sized1 Ph❑3 Ph Size: 300 A #Meters Old Meter# ❑New ServiceOFire ReeonnectOFlood ReconnectoGervice ReconnectOUnderground Overhead #Underground Laterals 1 2 0 H Frame F1 Pole Work done on Service? DY N Additional Information: PAYMENT DUE WITH APPLICATION 13-149 LOT AREA = 28,823 SQ.FT. (0.662 ACRES) 16-154 22-12 DATUM NAVD 1988 1000-99-3-1 1000-99-1-1 1000-99-3-2 - dwelling/well dwelling/well well greater than 150' well greater than 150' dwelling/public water from property from property �stin9 W° (74.2) viv S OND 74, t 66•hr 75.8 01 `51 N 1 5 < 6 76 78 ` o O bw=77.8' q� O tw=79.5' O� tw 81.4' bw=79.0' bw 78.6' tw=81.6' n � k X N (O a $� tw=$3.0 O .... � n ITT Q o tD CO �,o1K {1 — 7 2 0 `� �'oso�H 3 ea�791 tIv 97. �O to o \ 1 , 1 o underground utilities °h. 35 652! 10•�> C O (�I as flogged and painted 0 66.5 el FR r v� O I by others man �LTE ��{ 2 s'$ ) '\ 4 CDn I 411 w I v {80.4} ip (5P �g,1 pCD atlO '� J moSonN m 1 d decK I � rnW 0 ►ri pot iv E 82 00 00 0 00 3 c � O O 50 M water A meter ® Z 75 (79.5) 6 (76.6) on (75.8) I76 _ S 73'00'30"W 152.50' LOT NUMBER 6 NOTE: dwelling/well Location of water mains & adjoiners water supply 1000-100-1-2 by others and are not well guaranteed. 0 REVISED 4-13-2022 TEST HOLE BY McDonald GeoServices UPDATED SURVEY, TOPO and ADDED HEALTH DEPT. INFO. 1-21-2022 ELEV.= 80.4 THE OMETS(OR.DIMENSIO"SHOWN HEREON FROM THE STRUCTURES Ta THE PROPERTY UNES ARE FOR A SPECIFIC PURPOSE AND USE AND THEREFORE ARE NOT JOB No. 13-149 FILE No. SALTAIRE ESTATES 0 INTENDED TD GUIDE 1HE ERECTION OF FENCES.RETAINING WALLS,POOLS.PATIOS, 1' DARK BROWN LOAM OL PLANTING AREAS.ADDITION m BUILDINTIS OR ANY OTHER coNsTRUCRON. TOPOGRAPHICAL SURVEY FOR GEORGE AND UN UTOF�N�RKO STATE EDUCATION O INIS LAW.��19 A Y1OLMON OF SMMON LOT NUMBER 5 ELIZABETH KOUVARAS MAP OF SALTAIRE ESTATES BROWN and PALE BROWN SURVLYGUAWISPREPARRM..AND ON WS SE SWL}P°W THE MTEPCOMPANY.G N FOR WHOM THE SITUATED AT MATTITUCK SILTY SAND AMM_..&1_�MNO.INSRIUIION USIFD HEREON.AND TO 1NE ASSIGNGES OF THE SM OR Su8mnnmom=uENr OWNER&.°w �` NOT TRANSFERns�e 10 aoDmDwa TNsnnm°Ns TOWN OF SOUTHOLD, SUFFOLK COUNTY, N.Y. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SM OR SCALE 1" = 30' DATE 11-3-2016 49' EMBOSSED SEAL W U.NOT BE CONSIDERED T°BE A VALID TRUE COPY FILED MAP No. 4682 DATE 8-3-1966 PALE BROWN FINE SAND CERTIFIED ON L �F N. SP �P eW TAX MAP No.(REF ONLY) 1000-100-1-1 DISK 2013 1.TI?ANoy 55' �® HAROLD F. TRANCHON JR. P.C. 09n� p2 LAND SURVEYOR 0. A COMMENTS: NO WATER ENCOUNTERED C_ y P.O. BOX 616 1866 WADING RIVER—MANOR RD. WADING RIVER, `✓m 117 g3 edf. LIC. 8992 63�1-929-4 95 . 04 HAROLD F. carar �� ENN. LIC. No. 2115—E 575000'50"yy ___ 152 50' - _ WATER SUPPLY LINE ---- ___-- - - ----------------------------- m 1,000 OALLON BURIED I 1 PROPANE TANK I l w _-Z -I--- - IIX I I GENERATOR ON i i 40'0 CONCRETE PAD; 13 Q rHT.'- INGROUND SWIMMING C�ENERAC' GUARDIAN I POOL (UNDER p SERIES 24KW cv In SEPARATE �- ' I .01APPLICATION) l o(1 EL.=82' I—�— --- -------- m I _ z � I ID i BLUE5TONE m I PATIO I I I '•- I N A I I CONDENSERS ON CONCRETE PAD I I`I, I COVERED PORCH EL.=84,1 2-5TORY WO. FR. G.O. // O WELLING ARAGEEMENT I ` vo BEDROOMS) I , 25°, F.F. EL.=84.5' GARAGE SLAB EL.=&2.1' EL.=84J I l EL.=82'1\ ZVI' � 1 � - COVERED PORCH f - v BURIED w I m I GAS LINE O W ' I � Q ❑❑❑ �� v IEL.=&2' EL.=82' I ,' Lu ASPHALT`� DRIVEWAY ❑ ,1,86. Q -4) o l ❑----------- /\0 4Q'El „ �. - ' / i EL.=78',1' DRIVEWAY 66 A� ENTRANCE N6,o5\,00 v EL.=74;- � o I PLAN -A 50ALE: ry 20,-0„ "a,® PROPOSAL FOR: MARK UP DATE: COMMENTS DATE: 04/12/24 KOUVARAS THESE PLANS ARE FOR DESIGN PURPOSES ONLY AND SHALL NOT BE USED FOR RESIDENCE JAARCMTECTURE CONSTRUCTION.THE DESIGNS PRESENTED HEREIN ARE THE PROPERTY OF AMP PAGE: ARCHITECTURE,LLC AND SHALL NOT BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION FROM ANTHONY PORTILLO,RA,LEED AP.THESE PLANS ARE SD 1 80 SOUNDVIEW AVENUE LLC PROTECTED AGAINST ANY UNAUTHORIZED USE UNDER FEDERAL LAW BY THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990(AWCPA),WHICH IL MATTITUCK,N.Y.11952 HASSEVERE PENALTIES. APP MO AS NOTED DATE•s B.P.# �6 FEE ! BY: NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REOt lJPFD FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBiiAG 3. INSULATION 4. FINAL-CONSTRUCTION MUST ELECTRICAL BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE INSPECTION REQUIRED REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDITIONS OF J, E WN ZBA WN PLANNING BOARD $ WN TRUSTEES C OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERfiIFICATL OF OCCUPANCY 1 -GENERAC° 20/22/24 kW 2024 GUARDIAN@ SERIES _ ?TG-PE q Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power'" Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz • Two-line multilingual digital LCD Evolution T"" controller G007209-0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor w '' '�; ,• • Standard Wi-Fig connectivity a • System status&maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENER'AC'..: _ • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.` 7; `Mustbe located away from doors,windows,and fresh air intakes and in accordance with local codes. ON or C �L Us nl I' https://assets.swri.org/libraryIDirectolyOfListedProducts/ us <X�,J Constructionindustry/973 DoC 204_13204-01-01_Rev9.pdf e LISTED Note:CETL or C U L certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER•"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEW- TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators, Mobile Link Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator.Included with model G007210-0. GENERAC GENERAC' �:.�.^. ... ��k PW Rom^! GENERAC� 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch(if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution—Controls • AUTO/MANUAIJOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. GENERAL 20/22/24 kW Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERACm 20/22/24 kW Specifications Generator Model G007038-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G007043-3 G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) 20,000 Watts* 22,000 Watts' 00,000 Watts' 22,000 Watts* 24,000 Watts* Rated maximum continuous power capacity(NG) _ 18,000 Watts* 19,500 Watts* 18,000 Watts* 19,500 Watts* 21,000 Watts* [Rated voltage 240 —s" Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 tTotal H` —armonic Distortion _ Less than 5% _ Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp ,Phase �� 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) T�a 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CC_A minimum "—i Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206 Dimensions(L x W x H)in/cm __ 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" 67 67 67 67 67 Sound output in d6(A}at 23 ft(7 m)with generator in QUlet-TestP'low-speed exercise mode** 5.5 _ 57 55 57 S7 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylindus 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic r mpression rat'io�'� 4 9,51 '— Starter 12 VDC Oil capacity including filter Approx.1.9 qt/1.8 L Operating rpm 3,600 fuel consumption Natural gas 113/hr(m3/hr) 1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane 0/hr(gai/hr)[Uhr] 1/2 Load 87(2.37)[8.99] 92(2.53)[9,57] 86(2.36)[8.95] 92(2.53)[9.57] !_ Full Load 130(3.56)[13.48] 142(3.90)114.77] 136(3.74)[14.15] 142(3.90)114.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO ' Automatic start Fututility failure.Weekly',Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. r OFF _ Stops unit.Power is removed.Control and charger still operate: Ready to Run/Maintenance messages Standard rEngine run hours indication -' Standard —� Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenancelogs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard ChargerFaulUMissingACwarning Standard Low Battery/Battery Problem Protection and Battery Condition indication-- Standard Automatic Vojiage Regulation with Over and Under Voltage Protection "` Standard Under-Frequency/Overload/Stepper Overcurrent Protection w Standard Safeiy FusedlFuse Protilem Protection _ - Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard FOvermank/Overspeed(@ 72 Hz)/rpm Sense LossShutdown Standard High Engine Temperature Shutdown Standard Internal FauFt lncerecl Wiring proiection Standard r Common external fault capability Standard FField upgradable firmware '^ _ Standard *Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,ISO3046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 10*F(6'C)above 60'F(16'Q. GENERAC3 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007039-1,G007039-3(20 I(W) • Intelligently manages up to four air conditioner loads with no additional hardware. G007043-2,6007043-3(22 kW)--_, ,No,of poles - 2 Y� ) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) µ 200 with Smart Management Modules(SMMs). 'Voltage rating(yAC) 120/240,10' • Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor(fixed)* • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Pick-up 80% -Dropout 65% • 2-pole,250 VAC contactors. �RReturn to Utility* Approx-13,sec r ' • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes* Standard �ETL or UL listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. "Circuit breaker protected _ 22,000, • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly 200 Amps 120/240,1a Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.8 1 30.1 10.5 13.5 6.9 cm 67.95 1 76.43 26.67 34.18 17.5 Hz "' ' I Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 L c DEPTH -Wp- PWRview Automatic Transfer Switch Features Model GO07210-0(24 kW) • Integrated PWRview monitor provides real-time energy usage data through PWRview app. tsNa of poles 2, Current rating(amps) 200 • Intelligently manages up to four air conditioner loads with no additional hardware. Voltage rating(VAC) 120/240;10 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(fixed)* with Smart Management Modules(SMMs). -Pick-up 80% • Electrically operated,mechanically-held contacts for fast,clean connections. -Dropout rum Approx.5%to Utility* r rox3 sec • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes* v Standard • 2-pole,250 VAC contactors. r TL or UL listed _ Standard• • Service equipment rated,dual coil design. Enclosure type NEMA 3R(Circuit breaker protected 22;000 • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly • Heavy duty Generac Contactor is an ETL recognized device. — w' Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width H2 H1 H2 W1 W2 I Depth in 26.8 1 30.1 10.5 13.5 1 6.9 cm 67.95 1 76.43 26.67 34.18 117.5 Wire Ranges DEPTH-I Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 210-#14 GENERAC' 20/22/24 kW Available Accessories _ (Model# M Product Description G005819-0 126R Wet Cell Battery ,E ev ry standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for !`.use with all air-cooled standby product(excluding PowerPact°). G007101-0 Battery Pad Warmer iPad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- lessary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be IContact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703 0 Bisque Touch-Up Paint Kit ;If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). 5007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor 'LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. 6007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-4G LTE Mobile Link"Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured! appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 637.6 mm 1218 mm [25.1 in] [48.0 in] G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 7272mm [28 6In] G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 p G o 0 G007209-0 696471071511 — G007210-0 696471078220 648 mm 1232 mm [25 51n] [48.5 1n1 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RACF Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000937814 Rev.B 07/30/2020