Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50700-Z
O�asUFFO(,�coGy Town of Southold 10/4/2024 a P.O.Box 1179 0 co 53095 Main Rd oy o� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45621 Date: 10/4/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 400 Legion Ave,Mattituck SCTM#: 473889 . Sec/Block/Lot: 142.-2-8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/5/2024 pursuant to which Building Permit No. 50700 dated 5/17/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing accessory garage as applied for. The certificate is issued to Constantin-Guild,Jennifer&Joseph of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50700 9/9/2024 PLUMBERS CERTIFICATION DATED A o iz d ignature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE 14 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50700 Date: 5/17/2024 Permission is hereby granted to: Constantin-Guild, Jennifer 400 Legion Ave Mattituck, NY 11952 To: install-roof-mounted solar panels on existing accessory garage as applied for. At premises located at: 400 Legion Ave, Mattituck SCTM #473889 Sec/Block/Lot# 142.-2-8 Pursuant to application dated 4/5/2024 and approved by the Building Inspector. To expire on 11/1612025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Bui ing Inspector - pF SOUj�o! Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q COMM N �� sean.devlinl town.southold.ny.us Southold,NY 1 1 97 1-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jennifer Constantin- Guild Address: 400 Legion Ave city.Mattituck st: NY zip: 11952 Building Permit#: 50699&50700 Section: 142 Block: 2 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement House X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12.75kW Roof Mounted PV Solar Energy System w/ (30) JKM425N-54HL4-B Modules, (2) Enphase IQ Combiners One Has(2) 220& (1) 215, Other Has(1) 220 & (1) 215, 40A AC Disconnect, Unfused Disconnect Solar On House &Acc. Garage Inspector Signature: Date: September 9, 2024 S.Devlin-Cert Electrical Compliance Form Copy OF SOUIyo� TOWN OF SOUTHOLD BUILDING DEPT. cn 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] ,FOUNDATION 2ND [ ] NS.ULATION/roe), LKING [ ] FRAMING /STRAPPING [ FINAL5v l� [ ] FIREPLACE & CHIMNEY [ ]. -FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]. FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: f iCi DATE INSPECTOR VOL � pFSOUTyo� �� TOWN OF SOUTHOLD BUILDING DEFT. , "r,oum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION- [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Are ,f r �Pwqr7 �fC) j DATE L4 INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS ►o FOUNDATION(1ST) , H ------------------------------------ C FOUNDATION (2ND) S O - C ' H ROUGH FRAMING& PLUMBING r H INSULATION PER N.Y. STATE ENERGY CODE C C� FINAL ADDITIONAL COMMENTS 7 2z5 2-4 OL + 60 4- �L. ✓' c c�I 'mil r - -au z x �J r C x E� H x d b H -7 DO BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 vo Southold, New York 11971-0959 7. Telephone (631) 765-1802 - FAX (631) 765-9502 Fogerr��sout"colu,cwnn, �o'.i - scan a, -so uthold'ownny., v APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date. 16 Company Name: e � eMcn4 C- ner-,A !q L-L-C,) Electrician's Name--Jxi ry-yc., Mlnnll"eK! License No.: J\_1 e Elec. email: P�r-rni +5 Elec. Phone No: -ojoj [!41 request an email copy of Certificate of Compliance Elec. Address.: -7 4-7 0 -,SL)�d_ a Vt., Z In 4-\&C K_d PV JOB SITE INFORMATION (All information Required) Name- Address: a of Cross Street: 11 Q, n �J Phone No.: (Z6 1 d"5-99 . 7 OLf I Bldg.Permit#- 50700 email: Pe-r-m4s L Tax Map District: 1000 Section'. I L4 Block: 0 � Lot: o oz BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): N4 Square Footage: Circle All That Apply: Is job ready for inspection?. F-1 YES N NO F—] Rough In ❑ Final Do you need a Temp Certificate?: 1:1 YES N NO issued On Temp Information: (All information required) Service SizeF1 1 PhF—]3 Ph Size: A # Meters Old Meter# FINew ServiceF-1 Fire ReconnectE]Flood Reconnect E]Service Reconnect Elunderground Eoverhead # Underground Laterals F 1 L]2 [] H Frame F] Pole Work done on Service? Y DN Additional Information:--r -(-[L"h Y—c-. c+ c d, K PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments APPRO EO AS NOTED SATE•S .Rt 5�7W FEE -SvD� BY: _ NOTIFY BUILDING DEPARTMENT AT 631765.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIO► & 1. FOUNDATION-TWO RFO !rlFra FOR POURED CONCRF .= 2. ROUGH-FRAMING&P 0flrlf"ll"G & INSULATION 4, FINAL-CONSTRUCTION MUST BE COMPLETE.FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CO DITIONS OF SOUTHOLD WN ZBA SOUTHO TOWN PLANNING BOARD SO TOWNTRUSTEES N,YS 0 SO OLD HPG HD OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED Page 1 of 2 w1 ' 03/25/2024 Current Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Joe Constantin-Guild Residence Project Address: 400 Legion Avenue, Mattituck, NY, 11952 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC.. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, ASCE 7-16 Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 oF NEwr Current Renewables Engineering Inc. Professional Engineer E cl info@currentrenewableseng.com FAA 106793 F NP Signed on:03/25/2024 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2of2 ,Summaries: Check 1: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 21 degrees and has a max beam span of 15.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 30 degrees and has a max beam span of 14.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 3: Shingle roofing supported by 2x4 Rafter @ 24 in. OC spacing. The roof is sloped at approximately 23 degrees and has a max beam span of 8.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com CODE INFORMATION ROOF MOUNT SOLAR PERMIT PACKAGE THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC .�E.O NEwr J O E CO N STA NTI N-GUILD POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: ��P0��k1 A. 0 2020 NEW YORK BUILDING CODE-BUILDING 12.000 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-RESIDENTIAL 2020 NEW YORK BUILDING CODE-EXISTING BUILDING 2020 NEW YORK BUILDING CODE-PLUMBING y 2020 NEW YORK BUILDING CODE-MECHANICAL `f�� 1067s3 400 LEGION AVE, MATTITUCK, NY 11952 2020 NEW YORK BUILDING CODE-ENERGY CONSERVATION A'��FESSIO�P� 2020 NEW YORK BUILDING CODE-FUEL GAS Exp:9/30/2025 2020 NEW YORK BUILDING CODE-ACCESSIBILITY STAMPED 03/29/2024 2020 NEW YORK FIRE PREVENTION CODE BUILDING INFORMATION 2017 NEWYORK NATIONAL ELECTRICAL CODE THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 2 STORY HOUSE SINGLE FAMILY RESIDENCE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY:R3/U AHJ :TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC ROOF:COMP SHINGLE APN:1000142000200000000 PV SYSTEM SUMMARY: 6 Current Renewables SYSTEM SIZE(DC) STC:400 x 30=12.000KW DC Engineering PTC: 376.70 x 30= 11.301 OKW DC SYSTEM SIZE(AC) 8.70OKW AC @ 240V CURRENT RENEWABLES MODULES (30)CANADIAN SOLAR:CS6R-40OMS-HL ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW CRENG.CO MICRO-INVERTERS ENPHASE: IQ8PLUS-72-2-US AERIAL VIEW VICINITY VIEW CONTRACTOR INFO MICRO-INVERTERS CITY 30 TILT 21°, 30°, 30°,23°,23' AZIMUTH 132°,222°,42°,222°,42' ROOF COMP SHINGLE RAFTER/TRUSS SIZE 2"X10"/2"X8"RAFTER @ 16"O.C./2X4 RAFTER @ 24"O.C. RAFTER @ 24"O.C. CZSYS! ATTACHMENT TYPE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP WITH IRONRIDGE XR-100 .} :- ELEMNTE ENERGY LLC. :.�. 7470 SOUND AVENUE,MATTTTUCK, EXISTING 200 AMPS MSP WITH 200 AMPS MAIN NEW YORK,11952 MAIN SERVICE PANEL - 'BREAKER ON TOP FED PH:(631)779 7993 1 services@e2sys.com INTERCONNECTION LOAD SIDE TAP � Licence-ME-52689 i ti. (MASTER ELECTRICIAN) OCPD RATING 50 AMPS Licence-HI- ROV (SUFFOLK HOME IMPROVEMENT) UTILITY PSEGLI I!'K t Solar Individual GENERAL NOTES: Permit Package 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES SHEET INDEX 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED JOE CONSTANTIN-GUILD 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV_1.0 COVER PAGE 12.000KW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL 400 LEGION AVE, GROUNDING ELECTRODE PV-3.0 STRUCTURAL MATTITUCK,NY 11952 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" PV-4.0 ELECTRICAL 3LD Rev Description Date 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS PV-5.O ELECTRICAL SLD 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" A INITIAL DESIGN 3/23l20 4 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM A 1 UPDATED DESIGN 3/27/2024 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM A2 UPDATED DESIGN 3/300024 COMPLIES WITH 690.35. PV-7.0 SIGNAGE OPPORTUNITY IOE CONSTANTIN-GUILD 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PV-7.1 PLACARD PROJECT# NA 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.0 MICROI NVERTER CHART DATE DRAWN 33012024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY E R 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/81,ABOVE ROOF SURFACE. PV-9.0 SAFETY PLAN 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE.TYPE NM CABLE SHEET# PV-1 0 ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH PV-10.0 SAFETY PLAN TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0+ SPEC. SHEETS 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: NOT E PATHWAYS: LEGEND NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON PROPERTY LINE NE{yy ALL BUILDINGS. UM UTILITY METER �Q ?,I A. �.p AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR c, 0� n (40 DRIVEWAY SIDE OF THE ROOF. I FENCE 186' FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM �__ _- _- SP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE - --------- ----� __-__-__-_ r SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING { r n THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE r SUB SUB PANEL OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS f 18-1�I' ISO 106793 ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS DRIVEWAY r WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR i .. + �c AC DISCONNECT AROFESSIONP� MECHANICAL EQUIPMENT. f 1 R324.6.2 SETBACK AT RIDGE: w EM 81'-11" Exp:9/30/2025 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 \ - COMBINER STAMPED 03/29/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN / i � AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A Q 52'-9" I CY) F JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 z REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A O �l I WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. ,n ,% RENEWABLES ENGINEERING INC. V 23'-7" ROOF OBSTRUCTIONS R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS w AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED J ROOF ACCESS POINT THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 4�'��__ __ __—__—__�_ Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. /I 149'-1 0" •R`en.ew� - ' A PATHWAY ON STREET FENCE/GATE Engineering PROPERTY LINE OR DRIVEWAY SIDE OF ROOF B FIRE ACCESS POINT CURRENT RENEWABLES ENGINEERING INC. WEE� _ _ _ _ _ — _ PHONE E(951)OAVE SUITE 36"ACCESS PATHWAYS aHONeI 95S)DOS-733507 WWW CRENG.CO 18"ACCESS PATHWAYS CONTRACTOR INFO NOTES: ENLARGE VIEW 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND Mont MEASUREMENTS. (N)COMBINER 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS EZSYS INCORPORATED INTO THE 2017 NEC AND UL (N)AC DISCONNECT STANDARD 1741. 3. EXISTING ROOF VENT SHOULD NOT BE (E) UTILITY METER ELEMENT ENERGY LLC. COVERED- 7470 SOUND AVENUE,MATTITUCK, (E)MAIN NEW YORK,11952 PH:(631)779 7993 NOTE: SERVICE PANEL services@e2sys.com REVENUE GRADE KWH PRODUCTION METER Licence-ME-52689 CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 ROOF OBSTRUCTION (MASTER ELECTRICIAN) STANDARDS. c A. uN Licence- - (SUFFOLK HOME IMPROVEMENT) LLjsue A (E)SUB PANEL Solar Individual Q Permit Package z JOE CONSTANTIN-GUILD O (N)AC DISCONNECT Q9 12.000KW Grid Tied J Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/2 312 0 2 4 A.1 UPDATED DESIGN 312712024 A 2 I UPDATED DESIGN 3/30/2024 OPPORTUNITY I IOECONSTANTIN-GUILD PROJECT# NA DATE DRAWN 313012024 DRAWN BY ER SITE �1/32�— �1 -�O' 36"ROOF ACCESS POINT ROOF7LINE136" SHEET# PV-20 ROOF ACCESS POINT TITLE SCALE: SITE PLAN ARRAY AREA LEGEND ' EAVE TO ROOF ROOF TOTAL ROOF ROOF TYPE AZIMUTH - #OF RIDGE ARRAY AREA AREA AREA AREA MODULES DIMENSION (Sq.Ft.) COVERED BY COVERED BY (Ft) (Sq.Ft.) ARRAY(%) ARRAY(%) UM UTILITY METER RS A #1 COMP SHINGLE 132 9 14.58 189.18 2111 8.96 *� (z) C4OF #2 COMP SHINGLE 222 6 13.50 126.12 2111 5.97 sP MAIN SERVICE PANEL #3 COMP SHINGLE 42 5 13.50 105.10 1 2111 1 4.98 29.87 r W #4 COMP SHINGLE 222 5 8.50 105.10 2111 4.98 SUB SUB PANEL #5 COMP SHINGLE 1 42 5 8.50 105.10 1 2111 4.98 S 106793 �C AC DISCONNECT �oA'��FESSIONP�� Exp:9/30/2025 (N)#30 CANADIAN SOLAR: CS6R-400MS-HL C� COMBINER STAMPED 03/29/2024 JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS ROOF#5 MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N)COMBINER ROOF OBSTRUCTIONS (N)AC DISCONNECT Current (E) UTILITY METER Renewables (E) MAIN SERVICE PANEL Engineering CURRENT RENEWABLES w ROOF#3 ENGINEERING INC. F. uM ROOF#4 RIVERSIDE 1700 AVE SUITE J-13.RIVERSIDE CA 92507 Q SUB PHONE.(951)-405-1733 WWW CRENG.CO z AC (E)SUB PANEL CONTRACTOR INFO _0 ILD J (N)AC DISCONNECT ®n STRUCTURAL NOTES : EZSYS 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE 7470 ELEMENTAVENUE,MATTITUCK, PROPOSED PV INSTALLATION ONLY. NEW YORK,11952 1'-6" 7993 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. PH.(631)779 services@e2sys.cos.com 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS Licence-ME-52689 (MASTER ELECTRICIAN) MUST FOLLOW MANUFACTURER GUIDELINES AND Licence-HI-67461 REQUIREMENTS. (SUFFOLK HOME IMPROVEMENT) 3' 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. Solar Individual 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR Permit Package ROOF#1 ROOF#2 INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY JOE CONSTANTIN-GUILD INCONSISTENCY BETWEEN SITE VERIFICATION AND 12.000KW Grid Tied FOLLOWING: - ROOF 1:2x10 RAFTERS @ 16" OC SPACING WITH MAX Photovoltaic System UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. 400 LEMON AVE, - ROOF 2&3: 2x8 RAFTERS @ 16" OC SPACING WITH MAX MATTITUCK,NY 11952 UNSUPPORTED SPAN EQUAL OR LESS THAN 14 FT. Rev Description I Date - ROOF 4&5: 2x4 RAFTERS @ 24" OC SPACING WITH MAX A INITIAL DESIGN 1 3/2 312 0 24 UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. Al UPDATED DESIGN 1 3/27/2024 rDRAWN ED DESIGN 3/30/2024 JOE CONSTANTIN-GUILD NA 313012024 ROOF PLAN ER 2 PV-2 1 TITLE SCALE: 3/32" = 1'-0" ROOF PLAN ROOF ROOF ROOFING ATTACHMENT TYPE FRAMING FRAMING OC PENETRATION PENETRATION MAX O NEIy NO TILT TYPE TYPE SIZE SPACING PATTERN SPACING OVERHANG �`Pt0 Rj a ( Yak q � ROOF 1 21 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x10" 16" FULLY STAGGERED 64" * A- ROOF 2 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16' FULLY STAGGERED 64" ROOF 3 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2„x8' 16 FULLY STAGGERED 64 24" �A'�O 106793106793�P�� Ss ROOF 4 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" Exp:9/30/2025 ROOF 5 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" STAMPED 03/29/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables CANADIAN SOLAR: CS6R-400MS-HL Engineering IRONRIDGE XR-100 CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE TABLE PENETRATION PHONE RIVERSIDE-1733 7 PHONE.(951)105-1733 WWW CRENG CO a• (E)COMP SHINGLE TWO OR MORE ROWS OF PANELS GUIDE FOR INSTALL CONTRACTORINFO IRONRIDGE UICKMOUNT HALO ULTRA GRIP 2.5 MIN.EMBED. Q C c SYS6 I I I I I ELEMENT ENERGY LLC. #14 X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING 7470 SOUND AVENUE,MATTITUCK, RAFTER NEW YORK,11952 PH:(631)779 7993 S lLicence-ME552689 ENLARGED VIEW (E)2"X10"/ 2"X8" RAFTER @ 16"O.C. l (MASTER e LHII-67461 2X4 RAFTER @ 24"O.C. (SUFFOLK HOME IMPROVEMENT) STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE XR-100 Permit Package IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ONE ROW OF PANELS JOE CONSTANTIN-GUILD CANADIAN SOLAR: CS6R-400MS-HL 12.000KW Grid Tied SEE ENLARGED VIEW Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 (E) 2"X10"/2"X8" RAFTER @ 16"O.C. 2X4 RAFTER @ 24" O.C. FULLY STAGGERED STACKED/STAGGERED Rev Date A INITIALTIAL DESIGN 3l23/2024 A.1 UPDATED DESIGN 3272024 A UPDATED DESIGN 3/30/2024 ATTACHMENTDETAILS (E)COMP SHINGLE OPPORTUNITY JOE CONSTANTINGUILD PROJECTS NA DATE DRAWN 3/30/2024 DRAWN BY ER SHEETS PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING BACKFEED FUSE SIZING MAX: CONTINUOUS OUTPUT 1.21A @ 240V MAX. CONTINUOUS OUTPUT 1.21A @ 240V OF NEl7,y �P� OE Mom/,q O'P 24.20 X 1.25 = 30.25AMPS 40A FUSES-OK (N)60 A FUSED AC 12.10 X 1.25 = 15.13AMPS 20A FUSES OK Gj �O DISCONNECT * ji (� SQUARE D D322NRB WITH 20 A FUSES, LU AWG#12,SKU:Q-12-RAW-300.THHN KNIFEBLADE. - W 1-#8 AWG,EGC 7HNM-2 099128 Z (10)IQBPLUS-72-2-US - LOCKABLE,NEMA 3R, MICROINVERTERS IN 314'OR LARGER PVC CONDUIT UL LISTED ZN� �C9\ V p CTRIGP 10 CANADIAN N yf� AROFESSIO-P� SOLAR:CS6R-40OMS-HL ----------------- -------- ---------------t -- --1 I I 3-#6 AWG,THWN-2 I STAMPED 03/29/2024 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC (E)1DDARATED MAIN BREAKER CONDUIT (END FED) I THESE DRAWINGS ARE SUBJECT TO (E)100A RATED COPYRIGHT PROTECTION BY US LAW. SUB PANEL 1 PH,120240V 60HZ I REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT N E)ZODA RATED E)unury RENEWABLES ENGINEERING INC ( ENPHASE) I MAIN SERVICE PANEL METER COMBINER BOX MODEL m i 1 PH.12o240V SDHZ NO#X2-I0-AM1-240-4 IN BREAKER REA ER Current MAIN(B�FED) CELL WIRE LESS Renewabies MODEM COMMS /'� IQ GATEWAY �T� -J Engineering (10)IQ8PLUS-72-2-US - m (N)LOAD Y\ MICROINVERTERS YN)15A:/ SIDE TAP CURRENT RENEWABLES m r (N)60A FUSED ENGINEERING INC. BRANCH-2 AC DISCONNECT 10 CANADIAN SQUARE D D322NRB 1760 CHICAGO AVE SUITE N WITH 40A FUSES, PHO ERIVERSIDE �7 SOLAR.CS6R-0OOMS-HL KNIFEBLADE, L- WWW.CRENG.CO '(N)2oAm LOCKABLE,NEMA 3R. (N)LOAD (10)IQ8PLUS-72-2-US --, �1 I ILL LISTED SIDE TAP MICROINVERTERS I (N)2oA//11\\ (E11ODA2P CONTRACTOR INFO 'f� SUBPANEL BREAKER TO UTILITY aI� H OVERHEAD BRANCH:I ---- I L---------- --- �e ^ -------------- -- l FEED 10 CANADIAN ___ _ ---- �- ----- N SOLAR-.CS6R-400MS-HL t r J F-%% WIRE RUN THROUGUGH CONDUIT I a nt «� 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 1J6 GEC.BARE AWG#12,SKU:Q-12-RAW-300.THHN 1-#8 EGC,THER P 1-#8 EGC,THWN-2 COPPER FREE AIR BONDED EXISTING ---- E 2 SYS8 1-#8 AWG.EGC THW uFER TIE IN N-2 CANADIAN IN 3l4"OR LARGER PVC IN 3/4"OR LARGER PVC L IN 3W OR LARGER PVC CONDUIT MODULE MANUFACTURER CONDUIT CONDUIT - SOLAR GROUNDING ELECTRODE CONDUCTOR*6 BARE COPPER MODULE MODEL CS6R-40OMS- ELEMENT ENERGY LLC. HL 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 MODULE(W) 400 PH:(631)779 7993 MODULE PTC(W) 376.70 NOTE: services@e2sys.com MODULE Isc(A) 13.85 REVENUE GRADE KWH PRODUCTION METER CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 Licence-ME-52689 STANDARDS. (MASTER ELECTRICIAN) MODULE Voc(V) 36.80 Licence-HI-67461 MODULE Imp(A) 12.99 NOTE: (SUFFOLK HOME IMPROVEMENT) MODULE Vmp IV) 30.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE 12.000KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT # QTY. AMPACITY RATING (°C) Photovoltaic System EQUIPMENT WIRE LOCATION WIRE FACTOR APPLIEDTO MORETHAN3 CONDUCTOR APPLIED TO Y SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY 400 LEGION AVE, MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO AC DISCONNECT EXTERIOR WALL 2 12 30 90° 12.10 0.96 1 28.80 15.13 A INITIAL DESIGN 3/23/2024 3 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 12.10 0.96 1 72 15.13 Al UPDATED DESIGN 32712024 A UPDATED DESIGN N30/2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 OPPORTUNITY JOECONSTANTIN-GUILD 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 12.10 0.96 1 28.80 15.13 PROJECT# NA DATE DRAWN 3/30/2024 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 24.20 0.96 1 52.8 30.25 DRAWN BY ER 7 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 24.20 0.96 1 72 30.25 SHEET# PV40 TITLE 8 AC ELECTRICAL 3LD 9 AC BACKFEED FUSE SIZING BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.21A @ 240V MAX. CONTINUOUS OUTPUT 1.21A @ 240V OF NEw y �P� pE M`�/iq 0'p 24.20 X 1.25 = 30.25AMPS 40A FUSES-OK (N)60 A FUSED AC 12.10 X 1.25 = 15.13AMPS 20A FUSES-OK 10 `9C DISCONNECT * G SQUARE D D322NRB 44, r_- 2 ' D D, WITH 20 A FUSES, AW3#12.SKU'.Q-12-RAW-300.THHN KNIFEBLADE, 0 UJ 1-M8 AWG,EGC THAN-2 m 10 IQBPLUSERTEUS - LOCKABLE,NEMA 3R. 099128 Z ( ) IN 314"OR LARGER PVC CONDUIT Z MICROINVERTERS UL LISTED < CTR1C 10 CANADIAN N a./'e ARO SSIONP� SOLAR:CS6R-00OMS-HL 3-#6 AWG,THWN-2 STAMPED 03/29/2024 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC (E)100ARATED MAIN BREAKER CONDUIT (END FED) THESE DRAWINGS ARE SUBJECT TO (E)IODA RATED COPYRIGHT PROTECTION BY US LAW. SUB PANEL 1 PH,120240VSDHZ REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT (N)ENPHASE MANS ER VIC E RATED (E)UTIUTY RENEWABLES ENGINEERING INC COMBINER BOX MODEL • METER 1PH,120240V 60HZ NO#X2-I Q-AM 1-240-4 E)zoDA)zP MAIN BREAKER Current (TOP FED) CELL WIRELESS MODEM COMMS Renewabfes _ IQGATEWAY �I� Engineering (10)IQBPLUS-72-2-US (N)LOAD Y\ MICROINVERTERS (N)15A:� SIDE TAP CURRENT RENEWABLES mm (N)60A FUSED BRANCH-2 ^ AC DISCONNECT ENGINEERING INC. SQUARE D D322NRB 1760 CHICAGO AVE SUITE 10 CANADIAN J-13.RIVERSIDE CA 92507 N .��. WITH 40A FUSES, SOLAR:CS6R-400M5-HL � (N)20A KNIFEBLADE, PHONE-.(951)305-1733 y' . LOCKABLE,NEMA 3R, WWW.CRENG.CO (10)I08PLUS-72-2-US -- (N)LOAD UL LISTED SIDE TAP MICROINVERTERS (N)2o O� ("BREAKER AER ' CONTRACTOR INFO SUBPANEL BREAKER To unuTr ERNEAD FEED BRANCH-3 �e FEED 10 CANADIAN N SOLAR:CS6R40)M5-HL EXISTING VNRE RUN THROUGH CONDUIT �.� 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 AWC3#12,SKU:O-I2-RAW-300,THHN Lamm 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 u 1-#6AWG.EGC THWN CANADIAN IN 3/4"OR LARGER PVC IN 314"OR LARGER PVC CZ SYS IN 314"OR LARGER PVC CONDUIT MODULE MANUFACTURER SOLAR CONDUIT CONDUIT _ (E)GROUNDING ELECTRODE CONDUCTOR#6 BARE COPPER MODULE MODEL CS6R-40OMS- ELEMENT ENERGY LLC. HL 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 MODULE(W) 400 PH:(631)779 7993 MODULE PTC(W) 376.70 NOTE: services@e2sys.com MODULE Isc(A) 13.85 REVENUE GRADE KWH PRODUCTION METER CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 Licence-ME-52689 STANDARDS. (MASTER ELECTRICIAN) MODULE Voc(V) 36.80 Licence-HI-67461 MODULE Imp(A) 12.99 NOTE: (SUFFOLK HOME IMPROVEMENT) MODULE Vmp IV) 30.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING STARTING ADJUSTMENT MAXIMUM TEMPERATURE 12.000KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT # QTY. AMPACITY RATING (°C) Photovoltaic System EQUIPMENT WIRE LOCATION WIRE FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO Y SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY 400 LEGION AVE, MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO AC DISCONNECT EXTERIOR WALL 2 12 30 90° 12.10 0.96 1 28.80 15.13 A INITIAL DESIGN 3/2MG24 3 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 12.10 0.96 1 72 15.13 Al UPDATED DESIGN 3/30/2024 A.2 UPDATED DESIGN 3/30/2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 OPPORTUNITY IOECONSTANTIN-GUILD 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 12.10 0.96 1 28.80 15.13 PROJECT# NA DATE DRAWN 3/30/2024 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 24.20 0.96 1 52.8 30.25 DRAWN BY ER 7 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 24.20 0.96 1 72 30.25 SHEET# PV-5.0 TITLE 8 AC ELECTRICAL SLD 9 AC CO MATERIAL LIST °F "Ewy ELECTRICAL EQUIPMENTS D W QTY. PART TYPE PART NUMBER DESCRIPTION i oss12s 30 MODULE CS6R-40OMS-HL CANADIAN SOLAR CS6R-40OMS-HL oA CTRIG 30 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US RO ssl°NP 1 COMBINER X2-1Q-AM1-240-4/4C ENPHASE COMBINER BOX X2-IQ-AM1-240-4/4C STAMPED03/29/2024 2 AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 311 UL LISTED THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 4 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS EXPRODUCTIO FORM IS EXPRESSLY FORRBIDDEBIDDE N WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 AIM CRENG.CO BREAKER / FUSES CONTRACTOR INFO QTY. PART TYPE PART NUMBER DESCRIPTION 2 BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) 1 FUSES 40A FUSES GENERAL 40A FUSES CL-'' SYSS 1 FUSES 20A FUSES GENERAL 20A FUSES ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 RACKING (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168A XR100, RAIL 168" BLACK Permit Package 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 JOE CONSTANTIN-GUILD 42 CLAMPS & GROUNDING UFO-CL-01-Al UNIVERSAL MODULE CLAMP, BLACK 36 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL 12.000KW Grid Tied 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE Photovoltaic System 84 ATTACHMENTS QM-HUG-01-M1 HALO ULTRAGRIP, MILL 400 MATTITUCK,LEGION NY 11952 84 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev I Description I Date 84 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE A I INITIAL DESIGN 1 3/232024 At UPDATED DESIGN 1 3272024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/302024 DRAWN BY ER SHEET# PV-6.0 TITLE BOM OF NEwy O CO /� GG PHOTOVOLTAIC n n 099128 2 • ■■ ■ ■ I• �� CTRIGP� AROSSIONP� 690.12 STAMPED 03/29/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS TURN RAPID EXPRESSLY FORBIDDEN WITHOUT PRIOR • WRITTEN APPROVAL FROM CURRENT RENE WABLES ENGINEERING INC. SHUTDOWN SWITCH TO ■ ` • ■ ■ AMPS THE "OFF" POSITION TO AC - - AC NORMAL OPERATING VOLTAGE1 VOLT SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current -s AND REDUCE SHOCK "WA_ Engineering HAZARD IN THE ARRAY PMDUAL POWER SOURCES CURRENT RENEWABLES 690.56(C)(1)(B) • 1 SOURCE PHOTO- • ENGINEERING INC. 1 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 ■ , 1 OUTPUT CURRENT • , ■ PHONE.(951)405-1733 WWW.CRENG.CO CONTRACTOR INFO 690.54 OPTIONAL SOLAR LOAD CENTER ARRAY EZSYS I ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, �/� NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN)WARNING" Licence-HI-67461 INVERTER OUTPUT • • (SUFFOLK HOME IMPROVEMENT) • NOT RELOCATE THIS NEC 690.31(G)(3)&(4),CRC R324.7 Solar Individual i OVERCURRENT DEVICE Permit Package (UNLESS BUSBAR IS FULLY RATED) — — 705.12(D)(2) PHOTOVOLTAIC POWER SOURCEJOE CONSTANTIN-GUILD EVERY 10'ON CONDUIT AND ENCLOSURES 12.000KW Grid Tied Photovoltaic System NOTES' 400 LEGION AVE, MATTITUCK,NY 11952 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. Rey Description I Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 1 3/23/2024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A 1 UPDATED DESIGN 1 3127/2024 A 2 UPDATED DESIGN 1 3/30/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OPPORTUNITY I IOE CONSTANTIN-GUILD B. RED BACKGROUND COLOR WHITE TEXT AND LINE PRDJEcra N WORK. A C. AERIAL FONT. DATE DRAWN 3/30/2024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN By E.R THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE sHEETa Pv-7.0 TITLE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. OF NEW Y rP o�E MANi,�9 O'p� * c5- k r - D W m ossizB 4 CTRIGP�. v �OFESSIONP CAUTION STAMPED 03/29/2024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES PV ARRAY ENGINEERING INC. —111 E ly 1760 CHICAGO AVE SUITE SUB PANEL > J-13.RIVERSIDE CA 92507 Q PHONE.(951)-405-1733 AC DISCONNECT Z WWW CRENG CO Ef 0 O CONTRACTORINFO w .J dom MAIN SERVICE PANEL UTILITY METER C2SYS9 AC DISCONNECT ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, COMBINER NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL JOE CONSTANTIN-GUILD PANEL IS AC DISCONNECT PER NEC690.17 12.000KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Dale A INITIAL DESIGN 3/23/2024 A.1 UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/3012024 DRAWN BY E.R SHEET# PV-7.1 TITLE PLACARD 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 MICROINVERTER CHART 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current Engineering CURRENT RENEWABLES ENGINEERING INC. 4 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG CO CONTRACTORINFO 5 ® rN EZSYS6 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 6 NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.000KW Grid Tied 8 Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 9 At UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOECONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY E.R SHEET# PV-8 0 10 TITLE MICROINVERTER CHART F7SAFETY PLAN MARK UP KEY INSTRUCTIONS: a COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. AC REPRODUCTION IN ANY FORM IS AC DISCONNECT EXPRESSLY FORBIDDEN WITHOUT PRIOR 2.SAFETY PLAN MUST BE MARKED BEFORE JOB WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN MSP MAIN SERVICE PANEL RENEWABLES ENGINEERING INC 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET N UTILITY METER Current IN CASE OF EMERGENCY OP PERMANENT ANCHOR RenewaEngineering bles NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC 16 JB JUNCTION BOX CURRENT RENEWABLES NAME: ENGINEERING INC. O TEMPORARY ANCHOR 1760 CHICAGO AVE SUITE ADDRESS: J-13.RIVERSIDE CA 92507 IL INSTALLER LADDER PHONE WWW CRENG.CO:(951)-405-1733 SAFETY COACH CONTACT INFORMATION :1 STUB-OUT CONTRACTOR INFO NAME: ADDRESS: ® SKYLIGHT NO LADDER ACCESS (STEEP GRADE ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE OR GROUND LEVEL OBSTRUCTIONS CZSYS3 SAFETY PLAN AND SIGN INDICATING THAT THEY ARE _ AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR ❑ WORKING SAFELY. RESTRICTED ACCESS ELEMENT ENERGY LLC. CONDUIT 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 NAME SIGNATURE GAS GAS SHUT OFF services@e2sys.com Licence-ME-52689 20 WATER SHUT OFF (MASTER ELECTRICIAN) Licence-HI-67461 OSERVICE DROP (SUFFOLK HOME IMPROVEMENT) O POWER LINES Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.000KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 DATE: TIME: Al UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 3/30/2D24 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY E.R SHEET# PV-9.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel,and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all The site supervisor shall forecast the weather conditions at the • Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind, rain,etc.) discretion(location is annotated below). If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure. Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission, location of suitable restroom facilities with COPYRIGHT PROTECTION S LAW. REPRODUCTION IN ANY FORM IS S uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. Elevated work involving the moving or maneuvering of solar If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure leaned against a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor Renewal 'ems • Additional notes: Crew leader responsible for communication with the client: 10 Engineering Name: Mobile Equipment • Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment,operators must Yes, No): Heat Related Illness Prevention Phone: CURRENT R ENGINEERINGG INC. LES NC. maintain a certification on their person for the equipment being I • Employees shall have access to potable drinking water that is 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13,RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE (951)-405-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: WWW.CRENG.CO • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift. Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees C�SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: u • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete;a fall rescue plan must be outlined and Crew member(name/title): New employees must be acclimatized. New employees will be of what happen and when. 7470 SOUND AVENUE,MATTITUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and connect • Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift. Employees must take Licence-ME-52669 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) Licence-HI-67461 • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Define the Hazard: Method/Steps t0 prevent Incident: (SUFFOL HOME IMPROVEMENT) • Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an JOE CONSTANTIN-GUILD electrically safe condition(de-energized)unless approval has • If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 12.000KW Grid Tied • Service drops and overhead electrical hazards will be If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: Photovoltaic System indentified and protected from contact as neccessa water(location/address): EQP(name and tile): • Who will replenish the drinking water(name): 400 LEGION AVE, MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 3/23/2024 At UPDATED DESIGN 3/27/2024 A2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN ,��r CanadianSofar ENGINEERING DRAWING(mm) CS6R-400MS-HL/I-VCURVES Rear View Frame Cross Section A-A /4 14 A-A13 12 - s-ms _ 35 _ 11 -- 11 THESE DRAWINGS ARE SUBJECT TO 10 _-_----.------ - ------ .-_-10..___-___-__ COPYRIGHT PROTECTION BY US LAW. s -- 9 --- REPRODUCTION IN ANY FORM IS 614 d ,,,,,M:,.,,,,k ,:=- .e� a __________ _._ • ____.___. EXPRESSLY FORBIDDEN WITHOUT PRIOR 7 _.__ .__ WRITTEN APPROVAL FROM CURRENT 6 _ 6 RENEWABLES ENGINEERING INC. 5 s $$0 4 - 4 - --- - 3 __-_.. 3 Mounting Hole Current , " a a Penewa�bles y 51075IDE303540K505660 51015ID 25 30 35 40 45 50 55 fA .............. ■ ,oilownr s•C■ Engineering HiKu6 (All-Black) - �- ■ 4wwrw 65•C. _... _-_.--z�--------- ■ 60ewrm 4s-c■ __>s _ ,1aF _ - _s - ■ 40°w""' 6sK R CURRENT RENEWABLES ALL BLACK MONO PERC 20Di* ENGINEERING INC. 1760 CHICAGO AVE SUITE 380 W ~ 405 W ELECTRICAL DATA I STC* MECHANICAL DATA J-13,RIVERSIDE CA 92507 C56R-380/385/39 fM/400/405MS-HL Specification Data PHONE WWW CRENC CO 05 1733 C56R-380 385(390 395 400(405MS-H L Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline CONTRACTOR INFO Opt.Operating Voltage(Vmp)30.0 Y 30.2 V 30.4 V 30.6 V 30.8 V 37.0 V Cell Arrangement 708 R X(9 X 6)) Opt Operating Current(Imp)12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A Dimensions 1722 it 1134 x 35 mm MORE POWER 5 1 Industry Leading Product Warranty on Materials Open Circuit Voltage(VOC1 36.0 Y 36.2 V 36.4 V 36 6 V 36 8 V 37.0 V (67.8 x 44.6 x 1,38 in) _ Years and Workmanshlp* Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 22.4 kg(49.4 lbs) Module power u to 405 W Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 min tempered glass with anti-ref- Ila In O p p Anodized coating `�5 W Module efficiency up to 20.7% Operating Temperature -00°C-+85"C Frame Anodized aluminium alloy, C�SYS� 5` Linear Power Performance Warranty* Max.System Voltage l000v(IEUUL) )-Box 1P68,3 bypass diodes Years / Module Fire Performance TYPE 2(UL 617301000V) Cable 4 mm1 pEC),12 AWG(UL) - or CLASS C(IEC 61730) ELEMENT ENERGY LLC. Lower LCOE&system cost 1"year power degradation no more than 2% Max.Series Fuse Rating 25 A ,M Connector T6,MC4C4-EV02 or MC4-EVOZA 7470 SOUND AVENUE,MATTITUCK,Subsequent annual power degradation no more than 0.55% NEW YORK,11952lication Classification Class A Cable Length APP..-____ -_- C 1550mm(61An1(+)/1100mm(433in)(-)* PH:(631)779 7993 *Subject[o theterms and conditions contained in the applicable Canadian Solar Limbed Power Tolerance 0-+10W Q � services@e2sys.com Comprehensive LID/LeTID mitigation Warranty Statement.Also this ZS_ limited productwarrantyisavailableonlyforprod- ucts installed and operating on residential rooftops in certain regions. •Under Standard Test Conditions MC)of kradiatce of 1000 W/rw,spectrum AM 1.5 and cal tempe- Per Pallet 30 pieces Licence-ME-52689 nll technology,up to 50%lower degradation _.............. ...................................-.-._------.----__........... _. _ .. . _ .- ratumof25"c. (MASTER ELECTRICIAN) Per Container(40'HQ)780 pieces MANAGEMENT SYSTEM CERTIFICATES* *For derailed information,please contact your local Canadian solar sales and Licence-H I-67461 150 9001:2015/Quality management system technical representatives. (SU F FO LK HOME IMPROVEMENT) Better shading tolerance ISO\`F 14001:2015/Standards for environmental management system 5f/ I5045001:2018/Internationalstandardsforoccupationalhealth&safety ELECTRICAL DATA NMOT* Solar Individual TEMPERATURE CHARACTERISTICS PRODUCT CERTIFICATES* CS6R-38o/385/390/395/400/405MS•HL Specification Data Permit Package MORE RELIABLE IEC 61215/IEC 61730/CE Nominal Max.Power_(_Pmax) 284 W 298 W 291 W 295 W 299 W 303 W CEC listed(US California)/FSEC(US Florida) Opt.Operating V m 28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0.34%/°C UL 61730/IEC 61701/IEC 62716 p g oltageN p) --- -- JOE CONSTANTIN-GUILD Take-e-way Opt.Operating Current(imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Voc) -0.26%/°C Q Minimizes micro-crack impacts d'r cv(/SAC Y Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/°C usiC E 01� 0 Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A Nominal Module Operating Temperature 42 t 3°C 12.000KW Grid Tied `The specific certificates applicable to different module types and markets will vary, -under Nominal Module Operating Temperature(NMOT),irradiate of SW W/mz spectrum AM 1.5, Photovoltaic System *** Heavy snow load up to 8100 Pa, and therefore not all of the certifications listed herein will simultaneously apply to the ambient temperature 20-C,wind speed 1 m/s. products you order or use.Please contact your local Canadian Solar sales representative PARTNER SECTION )� wind load up to 5000 Pa* to confirm the specific certificates available for your Product and applicable in the regions ;............................................................_.................................................... 400 LEGION AVE, in which the products will be used. MATTITUCK NY 11952 ......................-..................._...................................._................--.......................... CST SOLAR(USA)CO.,LTD.is committed to providing high quality Rev Description Date solar photovoltaic modules,solar energy and battery storage solutions to customers.The COm Was recognized as the No.1 module supplier for *The specifications and A INITIAL DESIGN 3/23/2024 party o9 ppl pec key features contained In this datasheet may deviate slightly from our actual quality and performance/price ratio In the IHS Module Customer Insight products due to the ongoing innovation and product enhancement.CSI Solar Co.,Ltd.reserves the A 1 UPDATED DESIGN 3/27/2024 Survey.Over the past 20 years,it has successfully delivered over 70 GW right to make necessary adjustment to the information described herein at any time without further A 2 UPDATED DESIGN 3 3012024 notice. For detailed information,please refer to the Installation Manual. Of premium-quality solar modules across the world. Please be kindly advised that PV modules should be handled and Installed by qualified people who OF JOE CO NSTANTI N-GU ILD .............................................•,..•.......,...,,.._.,._,_,,,,.....,.,....,,.._._....,,.,..,..,..... have professional skills and please carefully read the safety and installation instructions before using ................................................................................................................................................ our PV modules. PROJECT# NA :................................................................................................................... CSI SOLAR(USA)CO.,LTD. _............................................................................................................................................. DATE DRAWN 3/30/2024 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94598,USA I www.csisolar.com/na I service.ca@csisolar.com DRAWN BY E.R CST SOLAR(USA)CO.,LTD. Aug 2022 I All rights reserved I PV Module Product Datasheet v1.1 C25_F23J1_NA SHEET# PV-11.0 TITLE MODULE SPEC ENPHASEe IQ8 and IQ8+ Microinverters Commonly used module pairings' W 235-350 235-440 Module compatibility _ To meet compatibility.PV modules must be within maximum input DC voltage and maximum module Ir listed below. Module compatibility can be checked at https://enphase.Com/imtallers/microinverters/calculator MPPT voltage range V 27-37 27-45 Operating range V 16-48 18-58 THESE DRAVIA NGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. Minimum/Maximum start voltage V 22/48 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Maximum input DC voltage V so 8o WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Missimum 1t1od1lel� -.._ A ___--------- _.. rrent iQ Overvoltage class DC port _ 11 ^... newables DC port backfeed current mA _ _ 0 (in Engineering PV army configuration - t.1 ungrounded array,no additional DC side protection required;AC side protection requires maximum 20 A per branch circuit. CURRENT RENEWABLES ENGINEERING Peak output power VA 245 300 1760 CH CAGO AVE SUITE Maximum continuous output power VA 240 290 J-13,RIVERSIDE CA 92507 PHONES(951)-405-1733 Nominal grid voltage(L-L) V 240,split-phase d--L),/00' WWW.CRENG.CO - IQ8 and IQ8+ Microinverters Easy to Instill Minimum andMndlnsngrid vokagez V 2f1-26 p _- ----- -----_ - __--- 4 CONTRACTOR INFO Lightweight and compact with plug- Mee mint 00 5 wo sadput cur erit A 10 - 1.21 ------ _-- Our newest I08 Microinverters are the industry's first microgrid forming.software defined and-play connectors — microinverters with it hase Nominal frequency Hz 80 spt i power conductor capability to convert o power ie AC power line communication(PLC) power efficierrtly.The brain of the semiconductor based microirtverter 1s our proprietary Extended frequency range H: 47-0 between components - - ------— --- ------ ---------- ----- -- BppIICStIOfl�peClflC Integrated circuit(ASIC),which enables the mlcranverter to operate in __- --��-�----- is grid-tied or off-grid modes.ThisAC short-circuit t�r.,to�chip is built using advanced 55-nm technology with high-speed Faster installation with simple two-wire Arms 2 digital logic and has superfast response times to changing bads and grid events.alleviating cabling three cycles EZSYSAu constraints on battery sizing for home energy systems. Maximum units per 20 A(L-U branch _ 15 13 drafts High productivity and reliability --- <5 ELEM ENT ENERGY LLC. • Produce power even when the grid is Total harmonic distortion % 7470 SOUND AVENUE,MATTRUCK, down OvervoltagedassACport ■ NEW YORK,11952 - -- - -- --— ----- PH:(631)779 7993 '€ More than one million cumulative hours AC port bed(feed current mA 30 i services(ale2sys.com o Licence-ME-52689 testing pow,erfaclaadpn9 - � (MASTER ELECTRICIAN) Class 11 double-insulated enclosure Grid-tied power factor(adjustable) - OA5 ending-•o•5 WgOW Licence-HI-67461 Part of the Enphase Energy System, I08 Series Microimrertersredefine Optimized for the latest high-powered POAmycleny % W.7 (SUFFOLK HOME IMPROVEMENT) I08 Series Microinverters integrate with the reliability standards with more than one PV modules ---- - IQ Battery,10 Gateway,and the million cumulative hours of pourer-on CEC weigtrted efficiency % 97 Enphase App monitoring and analysis testing,enabling an industry-leading Microgrid-forming Nighttime Solar Individual software. limited warranty Of up t0 25 years. g power consumption mW 23 25 Compliant with the latest advanced Permit Package grid support" Ambient temperature range -40'C to 60'C(-40'F to 140'F) • Remote automatic updates for the JOE CONSTANTIN-GUILD latest grid requirements Relative humidity range 4%to 100%(condensing) r Configurable to support a wide range DC connector type MC4 12.000KW Grid Tied Of grid profiles Dimensions(H a W a D) 212 mm(8.3 in)•175 mm(5.9 in)-30.2 mm 0.2 in) Meet CA Rule 21(UL 1741-SA)and IEEE' Photovoltaic System Connect PV modules quickly and easily I08 Series Microinverters are UL Listed Meet 1.08 kg(2.361bs) to I08 Series Microinverters using the as PV rapid shutdown equipment and 1547:2018(UL 1741-SB 3"Ed.) included Q-DCC-2 adapter cable with conform with various regulations.when Coding Natural convection-no tans 400 LEGIONAVE, 1 plug-arid-play MC4connectors. installed according to the manufacturer's NOtE: Approved for wet locations Yes MATTITUCK,NY 1952 Instructions. - toe Microlnveners cannot be mined with PD3 Pollution degree Rev Description Date previous generations of Enphase mcroinveners (107 series.106 Series.and so on)in the same Enclosure Class 11 double-insulated,corrosion-resistant polymeric enclosure A INITIAL DESIGN 3/23/2024 system. 10 Gateway is required to change the default Environmental category/UV exposure rating NEMA type 6/0utdoor A.1 UPDATED DESIGN 3/2712024 A2 UPDATED DESIGN 3/30/2024 -Meets UL 1741 only when installed with 10 System Commiler 2. grid profile at the time of installati n to meet sessessess -108 and K38-support Spit-phase.240 Vvetaeet—only. local Authority Having Jurisdiction(AHJ) OPPORTUNITY JOECONSTANTIN-GUILD requirements. b)ho mlw�w ocnc raw. PROJECT# NA C 2023 Enphase Energy.AN rights reserved.Enphem.the a and CC logos,K1 and certain other marks listed at (2)Ib rW.ox.ge rargaoen be se�biz rO r,omlrW s rsovi.aa by the utility fttmaJ/enphase.cent/treoemerk-usage-guafelings aro trademarks of Enphase,Energy.Inc ir mthe USand other co.imes.Datasubject tcchangs. 10esp-12q-D$H-0020?-20-B 0FUS-2=3-10- (At.tmro may vey.asartoww requM«n.nt•mr>.nnenw numm�otmmram rtrsmrxariM in wvr arse. 1085P-12A-D5H-00207-2.0-EN-US-2023-10-13 DATE DRAWN 3/30/2024 DRAWN BY E.R SHEET# PV-11.1 TITLE MICROINVERTER SPEC is Enphase IQ Combiner 4/4C Data Sheet MODEL NUMBER Enphase Networking IQ Combiner 4(X-IQ AM1-240-4) IQ Combiner 4 with Enphase 10 Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+1-0 5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the 10 Battery system and 10 System Controller 2 and to deflect heat. IQ Combiner 4C(X 10 AM1 240 4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-Mt-06-SP-05),aplug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enpl{,�lase The Enphase IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the 10 Battery and 10 System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) THESE DRAWINGS ARE SUBJECT TO IQ Gateway and integrated LTE-M1 cell - -------------- —---- -------- - - -- Q Combiner 4/4 C Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for COPYRIGHT PROTECTION BY US LAW. modem (included only with IQ Combiner 4C) COMMS-CELLMODEM-Ml-06 Ensemble sites REPRODUCTION IN ANY FORM IS CELLMODEM-Mt-06-SP-05 4G based LTE-Ml cellular modem with 5-year Sprint data plan EXPRESSLY FORBIDDEN WITHOUT PRIOR X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-Mt-06-AT_05 — 4G based LTE-Ml cellular modem with 5-year AT&T data plan — WRITTEN APPROVAL FROM CURRENT Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers RE NEWABLES ENGINEERING INC. X-IQ-A1M1-240-4C into a single enclosure and streamlines IQ BRK-IOA-2-240V Circuit breaker,2 pole,IOA,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A.Eaton BR215 microinverters and storage installations by BRK-20A-2P-240V Circuit breaker,2pole.20A,Eaton BR220 Current BRK-15A-2P-24OV-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support providing a consistent,pre-wired solution for BRK-20A-2P-24OV-8 Circuit breaker,2 pole 20A,Eaton BR2208 with hold down kit support Renewablf e residential applications. It offers up to four EPLC-01 XA-SOLARSHIELD-ES Replacement solar shield for IQ Comb Power line carrier bridge pair),quantrty-one pair -� ------------- - - --------- ----- — --- Engineering iner 4/4C 16 2-pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Une Carrier in 10 Combiner 4/4C(required for EPLC-01) ENoHASE CURRENT RENEWABLES busbar assembly. XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board!PCB)for Combiner 4/4C ENGINEERING INC. I X-10-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 ELECTRICAL SPECIFICATIONS PHONE(951)-405-1733 W W W.CRENG.CO Smart Rating Continuous duty • Includes IQ Gateway for communication and control system voltage 120{240 VAC 60 Hz CONTRACTOR INFO— — -- - _ Includes Enphase Mobile Connect cellular modem Eaton BR series busbar rating 125 A (CELLMODEM-M7-06-SP-05),included Only with IQ Max.continuous current rating 65 A Combiner 4C Max-continuous current rating(inpiit from PVistorage) 64A Includes solar shield to match Enphase IQ Battery Max fuse/circuit rating(output) 90 A • aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton OR series Distributed Generation(DG)breakers only(not included) �_ ��T/� Flexible networking supports Wi-Fi, - Max total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included Ethernet,or cellular Envoy breaker 10A or 15A rating GE/StemensiEaton included Optional AC receptacle available for PLC bridge - ----- -- - ---- - - ------- ----- -- -- --- ELEMENT ENERGY LLC. Provides production metering and consumption Production metering CT 200 A solid core pre-installed and wired to 10 Gateway 7470 SOUND AVENUE,MATTnUCK, monitoring Consumption monitonng CT(CT-200-SPLIT) A pair of 200 A split core currem transformers NEW YO RK,11952 PH:(631)779 7993 MECHANICAL DATA services@e2sys.com Dimensions(W xHxD) 37.5 x 49.5 x 16.8 cm(14.75•x 19 5•x 6.63").Height is 21.W(53.5 cm)with mounting brackets. Licence-M E-52689 Simple Weigh 7 5 kg(16.5lbs) (MASTER ELECTRICIAN) Licence-HI-67461 Centered mounting brackets support single Ambient temperature range -401 c to+46"C(-40"to 115-F) (SUFFOLK HOME IMPROVEMENT) stud mounting Cooling Natural convectior,plus heat shield Supports bottom,back and side conduit entry Enclosure environmental rating Outdoor.NRTL-certified.NEMA type 3R,polycarbonate construction Solar Individual Up to four 2-pole branch circuits for 240 VAC • plug-in breakers(not included) wire sizes 20 A to 50 A breaker inputs 1410 4 AWG copper conductors Permit Package X40-AM1-240-4C BOA total PV or Storage branch Circuits 60 breaker branch Input:4 to 1/0 AWG copper conductors • Main lug combined output.10 to 2/0 AWG copper conductors I Neutral and ground 14 to 1/0 copper conductors JOE CONSTANTIN-GUILD Always follow local code requirements for conductor sizing. Reliable Altitude To 2000 meters(6,560 feet) _ 12.000KW Grid Tied Durable NRTL-certified NEMA type 3R enclosure INTERNET CONNECTION OPTIONS _• Five-year limited warranty Integrated Wt-Fi 802.11b/g/n Photovoltaic System Two years labor reimbursement program coverage Cellular CELLMODEM-Mt-06 SP-05,CELLMODEM Mt-06-AT-05(4G based LTE-M1 cellular modem) NotethatanEnphase 400 LEGION AVE, included for both the IQ Combiner SKU's Mobile Connect cellular modem is required for all Ensemble installations Ethemet Optional,802.3,CatSE(or Cat 6)UTP Ethernet cable(not Included) MATTITUCK,NY 11952 UL listed - COMPLIANCE _. Rev Description Date Compliance.IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1.47 CFR,Part 15,Class B,ICES 003 A INITIAL DESIGN 3123/2024 Production metering:ANSI C12.20 accuracy class 0.5(PV production) • • Consumption metering accuracy class 2.5 A UPDATED DESIGN 327/2024 X4Q-AM1-240-4 Compliance,IQ Gateway UL 60601-1/CANCSA 222 No.61010-1 A 2 UPDATED DESIGN 3/30/2024 LAM OPPORTUNITY IOE CONSTANTIN-GUILD To learn more about Enphase offerings,visit enghhbb� s4m EN P H AS E. To learn more about Enphase offerings,visit enlDhase.com EN PHAS E. PROJECT# NA C 2022 Enphase Energy.All rights reserved.Enphase the Enphase logo.IQ Combiner 4/4C.and other names are trademarks of DATE DRAWN 3/30/2024 Enphase Energy Inc.Data subject to change.02-14-2022 DRAWN BY ER SHEET# PV-11.2 TITLE COMBINER SPEC /lam IRONRIDGE XR Rail" Family XR Rail`' Family The XR Rail S Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar IS Not Always Sunrn design loads. while minimizing material costs. Depending on your location,there is an XR Rail'A'to match. Over their lifetime. solar panels experience countless THESE DRAWINGS ARE SUBJECT TO extreme weather events. Not just the worst storms in years, COPYRIGHT PROTECTION BY US LAW REPRODUCTION IN ANY FORM IS but the worst storms in 40 years. High winds capable of EXPRESSLY FORBIDDEN WITHOUT PRIOR ripping panels from a roof, and snowfalls weighing ��\ WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. enough to buckle a panel trame. _ XR Rails R are the structural backbone 0, �_W- A preventing these results.They resist uplift. XR10 XR100 XR1000 Current D {�► protect against buckling and safely XR10 is a sleek.low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among _ ,`� 5 and efficiently transfer loads into the rail,designed for regions with fight or mounting rail.It supports a range of solar mounting rails.It's built to handle Engineering building structure.Their superior ` - no snow It achieves spans up to 6 feet, wind and snow conditions.while also extreme climates and spans up to 12 spanning capability requires fewer while remaining light and economical maximizing spans up to 10 feet. feet for commercial applications CURRENT RENEWABLES roof attachments. reducing the 6'spanning Capability 10'spanning capability 12 spanning Capability ENGINEERING INC. number Of roof penetrations Clear load capability Heavy load capability Extreme load capability 1760 CHICAGO AVE SUITE Clear&black anodized finish Clear&black anodized finish Clear anodized finish J-13,RIVERSIDE CA 92507 and the amount of PHONE:(951)-405-1733 i• Internal splices available Internal splices available Internal splices available WWW.cRENG.CO installation time. ,r CONTRACTOR INFO { Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.' Values are _ based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof all OR Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. 9 EZSYS� Rail Span ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, • • � minnow O NEW YORK,11952 PH:(631)779 7993 Force-Stabilizing Curve 90 services@e2sys.com SkDped roofs generate both vertical and lateral Licence-ME-52689 forces on mounting rails which can cause them to 120 (MASTER ELECTRICIAN) bend and twist The curved shape of XR RailsS None Licence-HI-67461 is specially designed to increase strength in both _ 14U XR10 XR100 ,XR1000 (SUFFOLK HOME IMPROVEMENT) directions while resisting the twisting This unique 160 / feature ensures greater security during extreme Solar Individual weather and a longer system lifetime. - Permit Package 120 20 JOE CONSTANTIN-GUILD 140 160 12.000KVV Grid Tied 90 Photovoltaic System I 30 160 400 LEGION AVE, Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials - MATTITUCK,NY 11952 90 XR Rails`are IronRidge°offers All XR Rails'are made of 6000-series 40 Rev Description Date compatible with , , a range of tilt leg aluminum alloy,then protected with an 160 A INITIAL DESIGN 3/23/2024 FlashFOot`and options for flat anodized finish.Anodizing prevents surface A.1 UPDATED DESIGN 3/27/2024 other pitched roof roof mounting and structural corrosion while also providing 80 160 attachments applications- La more attractive appearance -- A.2 UPDATED DESIGN 3/30/2024 120 160 _ OPPORTUNITY JOE CONSTANTIN-GUILD •Table is meant to be a simiciifiec span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. PROJECT n NA DATE DRAWN 3/30/2024 DRAWNB ER 2023 " ,��_ SHEET#Y PV-11 3 TITLE RAIL SPEC /I I RON RI DGE QuickMount ® Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home,solar attachments . • THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. COPYRIGHT PROTECTION BY US LAW. _ REPRODUCTION IN ANY FORM IS Due to recent innovations, many asphalt shingles EXPRESSLY FORBIDDEN WITHOUT PRIOR have bonded courses.A mount that protects Without - — -- W - --- .... ....- WRITTEN APPROVAL FROM CURRENT the need to pry shingles can really speed things up. - + + + RENEWABLES ENGINEERING INC Halo UltraGriW(HUG�)is here to respect the roof. • Its Halo is a cast-aluminum barrier that encases the Current UltraGrip,our industrial-grade,foam-and-mastic Rene wables seal-This allows HUG to accelerate the installation Engineering process and provide the utmost in waterproofing 9 Try it again!!!11111110 Still no luck?Install the rest. Hit the rafter? ! Miss the rafter. protection-Give your roof a HUG. od to - can • ••• on. another to the left or If It • _than 3 screws miss the rafter, CURRENT RENEWABLES • o, nd youneeded. found. •.nd final screw secure six screws to•_ ENGINEERING INC. Structural Screws are ck mount it. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG.CO Multi-Tiered Waterproofing HUG`utilizes a multi-tiered stack of CONTRACTOR INFO components to provide revolutionary Trusted Strength & Less Hassle waterproofing protection.The Halo cast- aluminum,raised-perimeterpbase foam- p foundation rids the Uttra6rip ba $ Structural capacities of HUG were reviewed in surrou ed mastic seal combination that many load directions,with racking rail running j ® _•._ ertts water intrusion by adhering ! a cross-slope or up-slope in relation to roof pitch. with the shingle surface. EZSYS9 Halo UltraGrip'"is part For further details,see the HUG certification of the QuickMount letters for attachingto rafters and decking. pro duct line. ELEMENT ENERGY 7470 SOUND AVENUE,MATTIAT'TINCK, " a IronRid designed the HUG, in combination NEW YORK,11952 g g PH:(631)779 7993 UltraGrips Seal Tech with the RD Structural Screw to streamline services@e2sys.com HUG UHraGnp utilizes a state Installs,which means the following: Licence-ME-52669 art seal design tflat uses a unique, (MASTER ELECTRICIAN) Licence-HI-67461 foarn-and-rtlasticcombination TtxY ; foam-backed adhesive provides No prying shingles (SUFFOLK HOME IMPROVEMENT) erMrey new flashing system that No roof nail interference conforms and adheres to every 25-Year Warranty and cranny ofcomposihostN Product No pilot holes necessary Solar Individual n filling gaps and shingle step - No sealant(in most cases) Permit Package (up to 1/8`in height). -� .._ No butyl shims needed JOE CONSTANTIN-GUILD Attachment Structural Water Seal UL 1 12.000KW Grid Tied . . . DesignRatings System Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUGS to the roof rafters.the roof HUG has been and certified for the UL 441 Section UL 2703 mechanical Rev Description Date a r deck or both with our custom-engineered A INITIAL DESIGN 3/2 312 0 24 Triple & —+r RD(rafter-or-deck)Structural Screw.The RD tested and rated to compliance with 27"Rain Test"and and bonding Q Tr Respect file Cwtfied Root . a Structural Screw anchors HUG to the roof support 1004(Ibs)of the International TAS 100(A)-95 requirements. See A, UPDATED DESIGN 3/30/2024 with an EPDM sealing washer,completing A2 uaonreD DESIGN 3/30/2024 UL2703.441(27) the stack of waterproofing barriers.see uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual OPPORTUNITY JOECONSTANTIN-GUILD kftftk_ TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY ER V r23 IronRidge,Inc.All rights reserved.Visit www.ir-patents.corn for patent information.Version , SHEET# PV-11.4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. Hayward,CA 94545 28357 Industrial Blvd. RON RI DGE 1-8Y Hayward,CA 94545 00-227-9523 I R O N R I D G E 1-800-227-9523 IronRidge.com IronRidge.com Attn:Corey Geiger,COO,IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following Date:September 711,2021 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1. THESE DRAWINGS ARE SUBJECT TO Re:Structural Certification and Span Tables for the IronRidge Flush Mount System COPYRIGHT PROTECTION S LAW REPRODUCTION IN ANY FORM IS S 2 Wind speed shall conform to ASCE 7-16 Fig,26 5-1 B(for Risk Category II)and applicable state&local EXPRESSLY FORBIDDEN WITHOUT PRIOR This letter addresses the structural performance and code compliance of IronRid e's Flush Mount System. The count /cit amendments to the IBC No special wind topographic features are included and both topographic WRITTEN APPROVAL FROM CURRENT P P 9 Ys Y Y PRENEWABLES ENGINEERING INC. contents of the letter shall be read in Its entirety before applying to any project design.The Flush Mount System is a coefficient(Kn)and wind ground elevation factor(Ke)are taken as 1.0 proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails 3 Snow load used in the span tables is the ground snow and shall conform to ASCE specified Fig. 1 and Current applicable state&local county/city amendments to the IBC.If the local jurisdiction specified snow load is in the and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof format of a flat roof snow,it shall first be converted to a ground snow following the local building code/ Renewables attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables No special snow conditions are considered -- Engineering that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding, retention,or ponding snow No rain-on-snow surcharge load is components are shown in Exhibit EX-0015. considered The span tables do not apply to buildings which are intentionally kept below freezing,keptjust above freezing,Or unheated. CURRENT RENEWABLES ENGINEERING INC. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 1760 CHICAGO AVE SUITE 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being. J-13 RIVERSIDE CA92507 listed below,for the load conditions and configurations tabulated in the attached span tables. PHONE(951)-405-1733 g p WWW.CRENG CO (a)For ground snow no greater than 42psf:Ss<_2.Og for Site Class A, B,C,&D. • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf SS<1 Og for Site Class A, B.C,&D CONTRACTOR INFO • 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf SS<_1.5g for Site Class A.B.C,&D • 2020 Building Code of New York State(BCNYS-2020, Published in November 2019) • 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in • Report SEAOC Structural Engineer Association of California PV2-2017 Wind Design for Solar Arra which the zones share the same External Pressure Coefficients(GC,). Roof zones comprising each group along p ( g ) g ys with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. ! a The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point.shall i C z SYS the respective loads and configurations listed, covering wind exposure categories B. C. &D, roof zones provided in be the lesser of the following two conditions 40%of the allowable span provided for the respective load ELEMENT ENERGY LLC. ASCE 7-16 for gable&hip roof profiles, and roof slopes of 8 to 45�.The tabulated spans are applicable when the &configuration condition from the span tables.or 36". 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 following conditions are met. 7 Allowable span length in the charts may be multiplied by a factor of 1 08 if the rails are continuous over PH:(631)779 7993 a minimum of three spans. services@e2sys.com Licence-ME-52689 1 Span is the distance between two adjacent roof attachment points(measured at the center of the attachment fastener) 8 No splices are allowed in the rail cantilever For each XR splice type install per the following requirements (MASTER ELECTRICIAN) Licence-HI-67461 a) XR Bonded Splice Cannot be Installed In the Center 1/3 Of Interior Spans.Or the outer 2/3 of end spans. (SUFFOLK HOME IMPROVEMENT) 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated b) BOSS Splice can be installed at any location within a span based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. Solar Individual 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If Permit Package 3 The underlying roof slope, measured between the roof surface and horizontal plane,is 80 to 450 such conditions are encountered Contact support@ironrdge com JOE CONSTANTIN-GUILD 4_ The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from grade.does not exceed 30 feet. 12.000KW Grid Tied Photovoltaic System 5. A clearance from the underside of the array to the roof surface of 2' minimum shall be provided and the height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not 400 LEGION AVE, MATTITUCK,NY 11952 exceed 10". Rev Description Date 6. Module length and area shall not exceed the maximum values listed on the respective span tables. A INITIAL DESIGN 3/23/2024 A.1 UPDATED DESIGN 3/27/2024 7 All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush A2 UPDATED DESIGN 3/30/2024 Mount Installation Manual and other applicable standards for the general roof construction practice OPPORTUNITY I IDE CONSTANTIN-GUILD PROJECT N NA DATE DRAWN 3/30/2024 DRAWN BY ER E 2021 IronRidge.Inc NY Flush Mount System Certification Letter-1 'E 2021 IronRidge Inc NY Flush Mount System Certification Letter-2 SHEET# PV-11 5 TITLE CERTIFICATION 28357 Industrial Blvd 28357 Industrial Blvd. Hayward,CA 94545 Hayward,CA 94545 RONRIDGE 1-800-227-9523 IRONRIDGE lronRi ge.co23 IronRidge com IronRidge.com 10. Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations(orphan modules)using modules with a length greater than 67.5".CAMO The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting clamps shall not be installed in regions that experience ground snow loads of 70psf and greater.Such scenarios are shown by asterisks in the applicable span tables. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration THESE DRAWINGS ARE SUBJECT TO b) CAMO will function within a module's design load ratings.Be sure the specific module being used with COPYRIGHT PROTECTION BY US LAW CAMO meets the dimensional requirements shown in the figure below and that the module selected is REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR suitable for the environmental conditions of a particular project. rF New WRITTEN APPROVAL FROM CURRENT Sincerely. Qom` �V (V `Q - 2 0 2 1 •O 9.O J RENEWABLES ENGINEERING INC. 15:45: 16 Module GioSS/Ceps 4;.'-�;A s � .- - Current r r 2 Renewabil` ,�" - -0 7 00 Engineering 9OFEssioN°'%� - Frome Compof@oi6ty' X=12-22 mm CURRENT RENEWABLES Y=15-40 mm Gang Xuan, PE 17G0 HI GO AVE SUITE Y - Senior Structural Engineer J-13.RIVERSIDE CA92507 PHONE(951)-405-1733 f- -X WWW.CRENG.CO Figurer CAMP Module Frame DimensionalRegfa'rements CONTRACTOR INFO Span values for Exposed and Edge module conditions,as defined below,are included in the attached span tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition, — — (2)The span value determined by site wind speed and ground snow load.Additionally, irrespective of the lesser CG-'SYS span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, Exposed Module conditions: H:(v1)77 n9s2 1. Ex p PH: 639 7993 services@e2sy5.Com A module is defined as Exposed(per Section 29 4 4 of ASCE 7-16)if the distance from any of its free Licence- (MASTER ELECTRICIAN) edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave, ridge,rake,or Licence-HI-67461 hip)is greater than 0 5h(h is ASCE defined building height)AND if the distance from Its free edge to any (SUFFOLK HOME IMPROVEMENT) other adjacent array or panel is greater than 4 feet. Solar Individual The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed Permit Package Modules, JOE CONSTANTIN-GUILD 2. Edge Module conditions: 12.000KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave.ridge, rake.or hip)is less than 2 times the height of the array(2h2) where h2 is measured from the roof surface to the top surface of the module. 400 LEGION AVE, MATTITUCK,NY 11952 The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Rev Description Date Additionally,if the roof edge is the eave or ridge.only the rail nearest to that roof edge shall be considered A INITIAL DESIGN 3/23/2024 for this span adjustment. At UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY I IOECONSTANTIN-GUILD C 2021 IronRidge.Inc NY Flush Mount System Certification Letter-3 Z-2021 IronRidge Inc NY Flush Mount System Certification Letter-4 PROJECT# NA DATE DRAWN 3/30/2024 DRAWN BY E R SHEET# PV-11.6 TITLE CERTIFICATION 0 011 ELEMENT ENERGY LLC. A ENDME NT CSYS8 7470 SOUND AVENUE, MATTITUCK, NEW YORK, 11952 6/14/2024 JOE CONSTANTIN-GUILD 8 2024 Job Address: 400 LEGION AVE, MATTITUCK, NY 11952 Plan revisions noted below. REV-4 Building®epatmant Town of Southold 1. Combiner box has been placed for the garage array. ROOF MOUNT SOLAR PERMIT PACKAGE CODE INFORMATION THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC .�`t,0 NEW y J O E CO N STA NT I N-GUILD POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: A. 2020 NEW YORK BUILDING CODE-BUILDING *�Q°e (4�c^� 2020 NEW YORK BUILDING CODE-RESIDENTIAL PVJUN 12.750 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-EXISTING BUILDING 2020 NEWYORK BUILDING CODE-PLUMBING 400 LEGION AVE, MATTITUCK, NY 11952 2020 NEWYORK BUILDING 2020 NEW YORK BUILDING CODE-ENERGYICAL CONSERVATION 1Ui6793NP\'��V � 8 � ssio 2020 NEW YORK BUILDING CODE-FUEL GAS xP/9/30/2025 2020 NEW YORK BUILDING CODE-ACCESSIBILITY evn STAMPED 06/1412024 2020 NEW YORK FIRE PREVENTION CODE dl17gD BUILDING INFORMATION 2017 NEW YORK NATIONAL ELECTRICAL CODE tc ,h O eP np f SO THE DRAWINGS ARE SUBJECT TO U�,r, COPYRIGHT PROTECTION BY US LAW. 2 STORY HOUSE SINGLE FAMILY RESIDENCE REPRODUCTION IN ANY FORM ISEXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U AHJ :TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC ROOF:COMP SHINGLE APN:1000142000200000000 PV SYSTEM SUMMARY: Current SYSTEM SIZE (DC) STC:425 x 30=12.750KW DCrl _ Renewables PTC:398.1 x 30=11.9430KW DC Engineering SYSTEM SIZE(AC) 9.600KW AC @ 240V CURRENT RENEWABLES MODULES (30)JINKO SOLAR:JKM425N-54HL4-B ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 WWW.CRENG.CO MICRO-INVERTERS ENPHASE: IQ8MC-72-M-US AERIAL VIEW VICINITY VIEW CONTRACTOR INFO MICRO-INVERTERS QTY 30 TILT 21°, 30°,30°,23°,23° - AZIMUTH 132° 222°42° 222° 42° ROOF COMP SHINGLE too RAFTER/TRUSS SIZE 2"X10"/2"X8"RAFTER @ 16"O.C./2X4 RAFTER @ 24"O.0 RAFTER @ 24"O.C. EZS T SU ATTACHMENT TYPE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP WITH IRONRIDGE XR-100 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTI[UCK, MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH 200 AMPS MAIN ! NEW YORK,11952 BREAKER ON TOP FED PH:(631)779 7993 INTERCONNECTION LINE SIDE TAP services---ME-5E-5268989 OCPD RATING 50 AMPS (MASTER ELECTRICIAN) Licence-HI-67461 UTILITY PSEGLI (SUFFOLK HOME IMPROVEMENT) yr GENERAL NOTES: Solar Individual 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION + Permit Package 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED SHEET INDEX JOE CONSTANT]N-GU ILD 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 6, ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 1 2.750KW Grid Tied 7, THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL PV-2.1 ROOF PLAN GROUNDING ELECTRODE 400 LEGION AVE, 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE PV-3.0 STRUCTURAL MATTITUCK,NY 11952 MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" PV-4.0 ELECTRICAL 3LD 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS Rev Description oath 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" PV-5.0 ELECTRICAL SLID A INITIAL DESIGN 3/23/2024 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BO M Al UPDATED DESIGN 3/27/2024 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM A2 UPDATED DESIGN 6n4121:1 COMPLIES WITH690.35. PV-7.0 SIGNAGE 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. OPPORTUNITY JOE CONSTANTIN-GUILD 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PV-7.1 PLACARD PROJECT# NA 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-80 M ICROI NVERTER CHART STANDARDS/MANUFACTURE . STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DATE DRAWN 6/14/2024 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/81,ABOVE ROOF SURFACE. PV-9.0 SAFETY PLAN DRAWN BY E R 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE SHEET# PV-1.0 ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)1013 OR 12/3 CONDUCTORS THROUGH PV-1 0.0 SAFETY PLAN TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0+ SPEC. SHEETS 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: NOTR324.6.1 PATHWAYS: ^LEGEND NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON PROPERTY LINE p��0 NEW�o ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER `~o0�R1 A l4O DRIVEWAY SIDE OF THE ROOF. FENCE FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM I 1 H6 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE - --- 7�----LL--------------------------- MSP MAIN SERVICE PANEL SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING TI C: W THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE i n OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS 1 81-1 I SUB SUB PANEL ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS , DRIVEWAY 106793 WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR { AC DISCONNECT AR�FESSIONP� MECHANICAL EQUIPMENT. CN �.�'. R324.6.2 SETBACK AT RIDGE: W L0 I ti' EM $ I1'-11" Exp:9/30/2025 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 > - a COMBINER STAMPED 06/14/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN OO AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A Q 52-9" M HORIZONTAL RIDGE. 7 1 (` J B JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 r COPYRIGHT PROTECTION BY US LAW. Z REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF BOTH LESS THAN A 36 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A O EXPRESSLY FORBIDDEN WITHOUT PRIOR_ MODULE WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. /n / �. RENEWABLES ENGINEERING INC. R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS LJJ \ 23-7 ROOF OBSTRUCTIONS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED J `� THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 44;71,�__ ------ ROOF ACCESS POINT Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. /I 149'-1 O" Renew"�;te5 A PATHWAY ON STREET FENCE/GATE Engineering OR DRIVEWAY SIDE OF ROOF PROPERTY LINE B FIRE ACCESS POINT CURRENT RENEWABLES ENGINEERING INC. WIIA0111'la CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE. 3 'A ATHWAYS PHONE:(951)-405-1733 WWW.CRENG.CO 18"ACCESS PATHWAYS CONTRACTOR INFO NOTES: ENLARGE VIEW 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND MEASUREMENTS. (N)COMBINER 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED INTO THE 2017 NEC AND UL CZSYS STANDARD 1741. (N)AC DISCONNECT 3. EXISTING ROOF VENT SHOULD NOT BE (E) UTILITY METER ELEMENT ENERGY LLC. COVERED. I I I Ll 7470 SOUND AVENUE,MATTITUCK, (E)MAIN NEWYORK,11952 NOTE: SERVICE PANEL PH:(631)779 services@e2sys.cos.com REVENUE GRADE KWH PRODUCTION METER Licence-ME-52689 CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 ROOF OBSTRUCTION (MASTER ELECTRICIAN) STANDARDS. c Ac uM Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) W SUB AC c Q (E)Sub PANEL Solar Individual Permit Package Z (N)COMBINER JOE CONSTANT]N-GUILD 0 (N)AC DISCONNECT 12.75OKW Grid Tied JPhotovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 A.1 UPDATED DESIGN 3/27/2024 A.2 I UPDATED DESIGN 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 SITE PLAN 36" ROOF ACCESS POINT DRAWN BY ER 1 ROOF LINE 36"ROOF ACCESS POINT SHEET# PV-2.0 SCALE: 1/32" = V-0" TITLE SITE PLAN ARRAY AREA AZIMUTH LEGEND NE{ EAVE TO ROOF ROOF TOTAL - #OF RIDGE ARRAY AREA AREA AREA AREA 0 ROOF ROOF TYPE yy MODULES DIMENSION (Sq.Ft.) COVERED BY COVERED BY (Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) `p (>I A. 0. #1 COMP SHINGLE 132 9 14.58 189.09 2111 8.96 UM UTILITY METER �00E - l410el #2 COMP SHINGLE 222 6 13.50 126.06 2111 5.97 MSP ~� #3 COMP SHINGLE 42 5 13.50 105.05 2111 4.98 29.86 MAIN SERVICE PANEL � �Ib Ck: 4J #4 COMP SHINGLE 222 5 8.50 105.05 2111 4.98 SUB SUB PANEL #5 COMP SHINGLE 42 5 8.50 105.05 2111 4.98 t� 106793 HC AC DISCONNECT '��FESSIONP�"� (N)#30 JINKO SOLAR: JKM425N-54HL4-B 5 c❑ COMBINER STAMPED 0 Exp:9/30/2024/2024 JE; JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. ROOF#5 a MOD REPRODUCTION IN ANY FORM IS MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N)COMBINER ROOF OBSTRUCTIONS (N)AC DISCONNECT Current (E) UTILITY METER Renewabies (E)MAIN SERVICE PANEL T Engineering CURRENT RENEWABLES W ROOF#3 ENGINEERING INC. C AC UM ROOF#4 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 Fa PHONE.(951)-405-1733 WWW.CRENG.CO zAc ` O (E)SUB PANEL CONTRACTOR INFO WMC OMBINER a ® (N)AC DISCONNECT EZSYSA STRUCTURAL NOTES : 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE ELEMENT ENERGY LLC. COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE 7470 SOUND NEWYOERK,11 52TTITUCK, T-6" PROPOSED PV INSTALLATION ONLY. PH:(631)7797993 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. Licence-Licence-ME-52689 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS (MASTER ELECTRICIAN) MUST FOLLOW MANUFACTURER GUIDELINES AND Licence-HI-67461 REQUIREMENTS. (SUFFOLK HOME IMPROVEMENT) 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL Solar Individual CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. Permit Package ROOF#1 ROOF#2 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE JOE CONSTANTIN-GUILD INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND 12.750KW Grid Tied FOLLOWING: Photovoltaic System - ROOF 1:2x10 RAFTERS @ 16" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. 400 LEGION AVE, - ROOF 2&3: 2x8 RAFTERS @ 16" OC SPACING WITH MAX MATTITUCK,NY 11952 UNSUPPORTED SPAN EQUAL OR LESS THAN 14 FT. Rev Dept— Date - ROOF 4&5: 2x4 RAFTERS @ 24" OC SPACING WITH MAX A INITIAL DESIGN 3/23/2024 UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. A, UPDATED DESI GN 6/14/224 A.2 UPDATED DESIGN 6t14/2024 OPPORTUNITY )OE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 ROOF PLAN DRAWN BY ER 2 SHEET# PV-2.1 TITLE SCALE: 3/32" = 1'-0" ROOF PLAN 'ROOF ROOF ROOFING FRAMING FRAMING ! OC PENETRATION MAX ATTACHMENT TYPE PENETRATION MAX p NE NO TILT TYPE TYPE SIZE SPACING PATTERN SPACING OVERHANG �P wy0 0�R1 A. 14 ROOF 1 21 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x10" 16" FULLY STAGGERED 64" ,. ROOF 2 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP r Q RAFTER 2"x8" 16" FULLY STAGGERED 64" ROOF 3 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16" FULLY STAGGERED 64" 24" A'�O106793NP���c, ssl ROOF 4 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" Exp:9/30/2025 ROOF 5 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 211X4" 24" FULLY STAGGERED 72" STAMPED 06/14/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC Curren; 0� n JINKO SOLAR: JKM425N-54HL4-B FCURRENT RENEW nninE c IRONRIDGE XR-100 ENGINEERING NCABLES 1760 CHICAGO AVE SUITE TABLE PENETRATION J-13RIVERSIDE92507 PHONE(961)dOS1733 GUIDE FOR INSTALL WWW CRENG CO a° (E)COMP SHINGLE CONTRACTOR INFO TWO OR MORE ROWS OF PANELS I 2.5,MIN.EMBED. IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ® El C2SYS8 #14 X 3"X RD STRUCTURAL WOOD SCREWS TO EXISTING I I I I I I I I I I I I I I I I I I ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTfTUCK, RAFTER NEW YORK,11952 PH:(631)779 7993 I I I I I I I I I I I I I I I I I services@e2sys.com Licence-ME-52689 ENLARGED VIEW (E) 2"x10"i 2"x8" RAFTER @ 16"O.C. I I I I I I I I I I I I I I I I I I I (MASTER ELECTRICIAN) 67461 2X4 RAFTER @ 24" O.C. Licence-HI- (SUFFOLK HOME IMPROVEMENT) STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE XR-100 Permit Package IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ONE ROW OF PANELS JOE CONSTANTIN-GUILD JINKO SOLAR: JKM425N-54HL4-B 12.750KW Grid Tied SEE ENLARGED VIEW I I I I I I I I I I I I I Photovoltaic System I I I I I I I I 400 LEGION AVE, MATTITUCK,NY 11952 (E)2"X4" RAFTER@ 24" O.C. FULLY STAGGERED STACKED/STAGGERED Rev Description I Date A INITIAL DESIGN 1 3/23/2024 At UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 16/142024 ATTACHMENTDETAILS (E)COMP SHINGLE OPPORTUNITY JOE CONSTANTIN-GUILD ]PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E.R SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING (N)ENPHASE BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.33A @ 240V COMBINER BOX MODEL MAX. CONTINUOUS OUTPUT 1.33A @ 240V NO#X2-I0-AM1-240-4 26.60 X 1.25 = 33.25AMPS 40A FUSES OKy 13.30 X 1.25 = 16.63AMPS 20A FUSES-OK OF NE(.yY CELL S 0 MODEM WIRE �P�o�E MA/y�� s � IQ GATEWAY * G MODULE MANUFACTURER JINKO SOLAR r ' D n W )16A'm r- (N)60 A FUSED AC MODULE MODEL JKM425N-54HL4-8 099128 Z DISCONNECT AwG#12.SKU:Q-t2ftAW 300,7HHN SQUARE D D322NRB MODULE(W) 425 �� CTRICI WITH 20 A FUSES, i-#8 AWG.EGc THWN-z FESSIO (10)IQBMC-72-M-US I KNIFEBLADE, MODULE PTC(W) 398.10 R P�' MICROINVERTERS w 3ra-OR LARGER PVC CONDUIT N oA 0 N I LOCKABLE,NEMA 3R, I UL LISTED MODULE Isc(A) 13.58 BRANCH-1 ("�0A'�` I STAMPED 06/14/2024 10 JINKO N I �b MODULE Voc IV) 38.95 SOLAR:JKM425N-54HL4-B __ _ __ ____ _ I I �e _ MODULE Imp(A) 13.13 -- L---- ------ --- -------------1 THESE DRAWINGS ARE SUBJECT TO -----y I MODULE Vmp(V) 32.37 COPYRIGHT PROTECTION BY US LAW. I REPRODUCTION IN ANY FORM IS 3-#10 AWG,THWN-2 3-#6 AWG,THWN-2 I EXPRESSLY FORBIDDEN WITHOUT PRIOR 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 I WRITTEN APPROVAL FROM CURRENT IN 314"OR LARGER PVC IN 3/4"OR LARGER PVC MAI BREAKER I RENEWABLES ENGINEERING INC. CONDUIT CONDUIT (END FED) I (EI100A RATE° SUB PANEL I 1 PH.12DQ4W 60HZ I Current ' Renewables (N)ENPHASE I (E)200A RATED (E)UTIUTY r COMBINER BOX MODEL I PH,120240VODH2 METER Engineering NO#X2-IQ-AM1-240-4 I NAiN REEAKER BR CURRENT RENEWABLES CELL WIRE LESS (TOP FED) ® ENGINEERING INC. MODEM COMMS 1760 CHICAGO AVE SUITE r-J J-13.RIVERSIDE CA 92507 IQ GATEWAY /T I PHONE.(951)<05-1733 /\ VVVVW CRENG CO (10CROIN ERTEUS -- N)15A:^ (N) LINESIDETAPVIA • CONTRACTOR INFO MICROINVERTERS r (N)6OA FUSED UL LISTED CONNECTOR AC DISCONNECT BRANCH10 SQUARE D D322NRB SOLAR:JKM425N�54HL4-B Nt I WITH 40A FUSES, 1 (N)LINESIDE TAP VIA UL (N)20A I KABLE, ADE, I : ` LISTED CONNECTOR -=�_ LOCKABLE,NEMA 3R, (El 1DDArn(10)IQBMC-ERTERS - N 0�T UL LISTEDUPANELBREAKER MICROINVERTERS BRANCH-3 I I TO RHEADCcSYS9 L.OVERIUITY� L----------- -------- �� Ik -------- -------------- -- FEED 10 JINKOSOLAR:JKM425N-54HL4Nt r-- - ---- ---- I J EXISTING VARE RUN ELEMENT ENERGY LLC. THROUGH CONDUIT 7470 SOUND AVENUE,MATTITUCK, 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 iBGEC.BARE NEW YORK,11952 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 COPPER FREE AIR L PH:(631)779 7993 AWG#12,SKU:Q-12-RAW-300,THHN IN 3/4"OR LARGER PVC IN 3/4"OR LARGER PVC BONDED EXISTING ----- 1-#8 AWG,EGC THWN-2 UFER TIE IN services@e2sys.com s.com IN 314-OR LARGER PVC CONDUIT CONDUIT CONDUIT _ (E)GROUNDING ELECTRODE Licence-ME-52689 CONDUCTOR 06 BARE COPPER (MASTER ELECTRICIAN) Licence-HI-67461 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE 12.750KW Grid Tied AWG CURRENT FACTOR FOR ADJUSTED CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION Photovoltaic System EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO # QTY. SIZE AMPA RATING (°C) CONDUCTORS IN FACTOR CONDUCTORS AMPACITY CONDUCTORS 400 LEGION AVE, 310.15(B)(1)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO COMBINER EXTERIOR WALL 2 12 30 90° 13.30 0.96 1 28.80 16.62 A INITIAL DESIGN 3/23/2024 A/ UPDATED DESIGN 3/2 712 0 2 4 3 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 10 40 90° 13.30 0.96 1 28.80 16.62 Az UPDATED DESIGN 6/14/2024 4 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 13.30 0.96 1 72 15.13 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA 5 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 DATE DRAWN 6/14/2024 DRAWN BY E.R 6 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.30 0.96 1 28.80 16.62 SHEET# PV-4.0 7 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 26.60 0.96 1 52.8 33.25 TITLE 8 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 26.60 0.96 1 72 33.25 ELECTRICAL KID BACKFEED FUSE SIZING BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 1.33A @ 240V (N)ENPHASE MAX. CONTINUOUS OUTPUT 1.33A @ 240V COMBINER BOX MODEL � ' 26.60 X 1.25 = 33.25AMPS 40A FUSES-OK NO#X2-IQ-AM1-24G-a 13.30 X 1.25 = 16.63AMPS 20A FUSES-OK OF NEw, CELL WIRE LESS �P Q�M"'��RI O�Q MODEM COMMS co MODULE MANUFACTURER JINKO SOLAR * G k IQ GATEWAY W MODULE MODEL KM425N-54HL4- n R` 099128 2 m (N)60 A FUSED AC MODULE(W) 425 Zz DISCONNECT �� SQUARE D D322NRB MODULE PTC(W) 398.10 CTRIC AWG#12,SKU:0-12-RAW-300,THHN .��. WITH 20 A FUSES An Q� , ,r (10)IQ8MC-72-M-US ,-#8AWG.EGCTHWN-2 KNIFEBLADE, MODULE Isc(A) 13.58 SSION MICROINVERTERS IN 3/4'OR LARGER PVC CONDUIT (N)20A LOCKABLE,NEMA 3R, UL LISTED MODULE Voc(V) 38.95 STAMPED 06/14/2024 BRANCHA N _j (NRDA.� 4.le MODULE Imp(A) 13.13 10 JINKO SOLAR:JKM425N-54HL4-B y� MODULE Vmp(V) 32.37 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR 3-#6 AWG,THWN-2 WRITTEN APPROVAL FROM CURRENT 3-#10 AWG,HWN-2THWN- 1-#8 EGC.THWN-2 RENEWABLES ENGINEERING INC 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC MAJN BREAKER ER IN 3/4"OR LARGER PVC MAIN BREAKER CONDUIT CONDUIT (END FED) (E)1 RATED Current SUB PANEL 1PM,1 SUB 20240V BOHZ Re-yew«wfes (N)ENPHASE (E)200ARATED (E)UTILIn 0`�n Engineering MAIN SERVICE PANEL METER COMBINER BOX MODEL m • 1 PH.120240V 60HZ NO#X2-IQ-AM1-240 4 (E)200A/2P CURRENT RENEWABLES MAIN BREAKER ENGINEERING INC. CELL WIRE LESS • (TOP FED) ®00, 1760 CHICAGO AVE SUITE MODEM COMMS RIVERSIDE CA 92507 PHONE.(951)-405A733 ID GATEWAY WWW.CRENG.CO (10)IQ8MC-72-M-US 1 CONTRACTOR INFO MICROINVERTERS (N),5 (N) UNESIDETAPVIA (N)60A FUSED T USTED CONNECTOR BRANCH-2 0�_ AC DISCONNECT SQUARE D DSE NRB 10 JINKO N �. WITH I40 FE FUSES, LIS LI LISTED CON TAP VIA UL mum _- SOLAR:JKM425N-54HL4-B KAB EBLADE, /` LISTED CONNECTOR w (N)20�� LOCKABLE,NEMA 3R, (E)1DDAr2P (10)IQ8MC-72-M-US -I w (N)2o�/T� UL LISTED SUBPANEL BREAKER I C z SYS9 MICROINVERTERS TO unury BRANCH-3 qfb OVERHEAD 0 JINK O °Lf�t FEED N ELEMENT ENERGY LLC. SOLAR:J KM425N-54HL4-B EXISTINGWIRE RUN 7470 SOUND AVENUE,MATTITUCK, THROUGH CONDUIT N EW YO RK,11952 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 PH:(631)779 7993 AWG*,2,SKU:0-12-RAW-300.THHN 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 services@e2sys.com -#8 AWG.EGC THWN-2 IN 3/4"OR LARGER PVC IN 3/4"OR LARGER PVC Licence-ME-52689 IN 3l4'DR LARGER PVC CONDUIT CONDUIT CONDUIT CONDUCTOR ELECTRODE (MASTER ELECTRICIAN) CONDUCTOR#6 BARE COPPER Licence-HI-67461 NOTE: (SUFFOLK HOME IMPROVEMENT) 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE SCHEDULE JOE CONSTANTIN-GUILD STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 12.75OKW Grid Tied AWG CURRENT FACTOR FOR ADJUSTED CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO Photovoltaic System # CITY. SIZE AMPA RATING (°C) CONDUCTORS IN FACTOR. ACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(1)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY 400 LEGION MATTITUCK,NY 11 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev De-pbw Date 2 AC MICROINVERTER TO COMBINER EXTERIOR WALL 2 12 30 90° 13.30 0.96 1 28.80 16.62 A INITIAL DESIGN 3/23/2024 3 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 10 40 90° 13.30 0.96 1 28.80 16.62 Al UPDATED DESIGN 3r27r2O24 A UPDATED DESIGN 6/14/2024 4 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 13.30 0.96 1 72 15.13 OPPORTUNITY JOE CONSTANTIN-GUILD 5 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 PROJECT# NA DRAWN 6114/2024 6 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.30 0.96 1 28.80 16.62 DRAWN DATE DRA A ER 7 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 26.60 0.96 1 52.8 33.25 SHEET# PV-5.0 8 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 26.60 0.96 1 72 33.25 TITLE ELECTRICAL SLD MATERIAL LIST OF NEwY P E MA/y� O,p ELECTRICAL EQUIPMENTS *�0 QTY. PART TYPE PART NUMBER DESCRIPTION z D W 30 MODULE CS6R-40OMS-HL CANADIAN SOLAR CS6R-40OMS-HL y ossin z 30 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US 1p.o < CTRIG 2 COMBINER X2-1 Q-AM 1-240-4/4C ENPHASE COMBINER BOX X2-IQ-AM1-240-4/4C A�OFEssl°NPR 2 AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED STAMPED 06/14/2024 4 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewable. Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE.(951).105-1733 WWW CRENG.CO CONTRACTOR INFO BREAKER / FUSES QTY. PART TYPE PART NUMBER DESCRIPTION 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ® nit FUSES 40A FUSES GENERAL 40A FUSES [2SYSB 1 FUSES 20A FUSES GENERAL 20A FUSES ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 RACKING (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168A XR100, RAIL 168" BLACK Permit Package 6 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 JOE CONSTANTIN-GUILD 42 CLAMPS & GROUNDING UFO-CL-01-Al UNIVERSAL MODULE CLAMP, BLACK 36 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL 12.750KW Grid Tied 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE Photovoltaic System 400 LEGION AVE, 84 ATTACHMENTS QM-HUG-01-M1 HALO ULTRAGRIP, MILL MATTITUCK, NY 11952 84 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Re Description I Jae 84 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE A UPDATED INITIALDDESIGESIGN 3/27/2024 Al UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 6/14/2024 OPPORTJNITY I JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY ER SHEET# PV-6.0 TITLE BOM ' ��pF NEI.yY �P ppE MMI/q_ O'p� PHOTOVOLTAIC SYSTEM, > EQUIPPED WITH RAPID 1• m 09912E 690.12 CTRIGPb SSIONP� L_ STAMPED 06/14/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS TURN RAPIDDISCONNECT EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT SHUTDOWN SWITCH TO RATED AC OUTPUT 39.90 • , . RENEWABLES ENGINEERING INC THE "OFF" POSITION TO AC AC NORMALOPERATING VOLTAGE1 VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current - - , AND REDUCE SHOCK = Renew- 1esEngineering HAZARD IN THE ARRAY PM DUAL • SOURCES CURRENT RENEWABLES 690.56(C)(1)(B) SECOND SOURCE PHOTO- VOLTAIC ENGINEERING INC.SYSTEM1760 CHICAGO AVE SUITE CA 92 RATED 1 OUTPUT . 39.90 • 1 . PHO EI`(95SI-405-1733507 AC r NORMAL OPERATING VOLTAGE 4 ' VOLTS WNW.CRENG.CO CONTRACTORINFO 69054 OPTIONAL SOLAR LOAD CENTER © n 0 0 ARRAY EZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, J/B NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) INVERTER Licence-HI-67461 OUTPUT CONNECTION (SUFFOLK HOME IMPROVEMENT) • NOT RELOCATEj NEC 690.31(G)(3)&(4),CRC R324.7 Solar Individual OVERCURRENT DEVICE "WARNING" Permit Package (UNLESS BUSBAR IS FULLY RATED) - — 705.12(D)(2) PHOTOVOLTAIC POVVER • JOE CONSTANTIN-GUILD EVERY 1VON CONDUIT AND ENCLOSURES 12.750KW Grid Tied Photovoltaic System NOTES. 400 LEGION AVE, 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS MATTITUCK,NY 11952 SHOWN HEREON. Rev Description I Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 3/23/2024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A UPDATED DESIGN 3/27/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. Az UPDATED DESIGN 6114/2024 B. RED BACKGROUND COLOR WHITE TEXT AND LINE OPPORTUNITY JOE CONSTANTIN-GUILD WORK. PROJECT# NA C. AERIAL FONT. DATE DRAWN 6/1412024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-7.0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. ��pF NEI,1,Y °'per * 4U G g D W m LU 099128 ZN�O cTRIGP�' A T I N ASS' CU O STAMPED 06/14/2024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC Current Renewables Engineering PV ARRAY SUB PANEL CURRENT RENEWABLES ENGINEERING INC. AC DISCONNECT W 1760 CHICAGRIVERSIDE AVE SUITE J-13.RIVERSIDE CA 92507 Q PHONE:(951).405.1733 COMBINER Z WWW CRENG CO O CONTRACTORINFO 0 L1_I J 171 MAIN SERVICE PANEL asm UTILITY METER CZ SYS9 AC DISCONNECT ELEMENT ENERGY LLC. COMBINER 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL JOE CONSTANTIN-GUILD PANEL IS AC DISCONNECT PER NEC690.17 12.75OKW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 A.1 UPDATED DESIGN 1 327/2024 A.2 UPDATED DESIGN 1 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E.R SHEET tl PV-7.1 TITLE PLACARD 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 MICROINVERTER CHART 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current 0-��n Renewables Engineering FM CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)405-1733 W WW CRENG.CO CONTRACTORINFO j3 5 E2SYSSU ELEMENT ENERGY LLC. 6 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package JOE CONSTANTIN-GUILD 8 12.750KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date 9 A INITIAL DESIGN 3/23/2024 A UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E.R 10 SHEET# PV-B 0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS- El COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. REPRODUCTION IN ANY FORM IS AC AC DISCONNECT EXPRESSLY FORBIDDEN WITHOUT PRIOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN MSP MAIN SERVICE PANEL RENEWABLES ENGINEERING INC 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET �M UTILITY METER Current IN CASE OF EMERGENCY O PERMANENT ANCHOR Renewabfes NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC Engineering JB JUNCTION BOX CURRENT RENEWABLES NAME: O TEMPORARY ANCHOR ENGINEERING 1760 CHICAGO AVE SUITE ADDRESS: arlo RIVERSIDE CA 33507 IL INSTALLER LADDER wwwcRENGDo SAFETY COACH CONTACT INFORMATIONEll S❑ STUB-OUT CONTRACTOR INFO NAME: ADDRESS: ® SKYLIGHT NO LADDER ACCESS STEEP GRADE ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE f SAFETY PLAN AND SIGN INDICATING THAT THEY ARE OR GROUND LEVEL OBSTRUCTIONS) EZSYSU AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR RESTRICTED ACCESS WORKING SAFELY. ELEMENT ENERGY LLC. CONDUIT 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 NAME SIGNATURE GAs GAS SHUT OFF PH:(631)7797993 services@e2sys.com Licence-ME-52689 20 WATER SHUT OFF (MASTER ELECTRICIAN) Licence-HI-67461 OSERVICE DROP (SUFFOLK HOME IMPROVEMENT) O POWER LINES Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.750KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 SATE TIME Al UPDATED DESIGN 3/27/2024 A UPDATED DESIGN 6114/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/14/2024 DRAVVN BY E.R SHEET# PV-9.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all • The site supervisor shall forecast the weather conditions at the Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations. Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below). If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure. Extension style ladders laced on work zone through the use of barriers and/or si na e,as • The site supervisor will utilized a portable wind meter COPYRIGHT PROTECTION BY US LAW. y p g g g p p permission,location of suitable restroom facilities with REPRODUCTION IN ANY FORM IS uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC. the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. • Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. Elevated work involving the moving or maneuvering of solar • If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure Renewables leaned a ainst a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor (� • Additional notes: Crew leader responsible for communication with the client: Engineering Name: Mobile Equipment Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment;operators must Yes, No): Heat Related Illness Prevention Phone: CURRENT RENEWABLES maintain a certification on their person for the equipment being • Employees shall have access to potable drinking water that is ENGINEERING INC. 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13,RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE(951)a05-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: WWWCRENG CO P 1 9 P 1 PP q Y 9 9 • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift. Employees may begin the Phone: Material Handling Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public. Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: • Crew member(namettitle): Shade shall be present when temperature exceeds SO degrees C�SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: • A site-specific plan for fall prevention and protection is required Crew member(name/title): SO degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description C. work is complete;a fall rescue plan must be outlined and • Crew member(namettitle): New employees must be acclimatized. New employees will be of what happen and when. ELEMENT ENERGY LL 7470 SOUND AVENUE,MATTITITUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and conned Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roofCrew member(name/title): scheduled breaks during each shift. Employees must take Licence-ME-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-HI-67461 • Asbestos-containingTransite piping ACP Do not disturb REQUIRED to allow employees an break period the need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) ( )PP 9( )- Y P Y FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an JOE CONSTANTIN-GUILD electrically safe condition(de-energized)unless approval has If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 12.75OKW Grid Tied • Service drops and overhead electrical hazards will be If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: indentified and protected from contact as neccessa water(location/address): Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 400 LEGION AVE, MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 3/23/2024 A UPDATED DESIGN 3127/2024 A.2 UPDATED DESIGN 611412024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 6/1 412 0 2 4 DRAWN BY ER SHEET# PV-10.0 TITLE SAFETY PLAN s� www.jinkosolar.com Jinl<O Building Your Trust ir,Sola.- Currant-yoltagc t Power-yultage Temperature Dependence at Tiger Neo N-t J ►Je - C-9 i4t� Ise,yM P_ 1 R - s .m 54HLf4-B - ,m IK THESE DRAWINGS ARE SUBJECT TO ' e t00 COPYRIGHT PROTECTION BY US LAW. 425 Watt f .-- - 310 Y �^ REPRODUCTION IN ANY FORM IS 10 i EXPRESSLY FORBIDDEN WITHOUT PRIOR -` WRITTEN APPROVAL FROM CURRENT ALL-BLACK MODULE t-i p -t--T- - - h- f RENEWABLES ENGINEERING INC N-Type tm., ,•, g.°. '° e u is s ,m Current Positive power tolerance of 0_+3% ReneWables Engineering IF.C61215(2016), IEC61730(2016) i IS09001:2015: Quality Management System -----------. ty CURRENTRENEWABLES �,m.-1, j ENGINEERING INC IS014001:2015: Enviro m Manag ement gement Sys,em 3 •� °"� _� I tell Type A type 11 -ensta-line 1760 CHICAGO AVE SUITE ISO45001:20Ig IM wvn x>•s J-13.RIVERSIDE CA 92507 ,-.._.._._.......r _• _- PHONE.(951)-405-1733 Occupational health and safety management systems t oar Dimensions 1722x 1134x 30•m (67.79x44-&5x 1.IS- WWW.CRENG.CO CONTRACTORINFO Front Glass 3.Gs..4non.ti-Reflectia,C+,,ag. Key Features High T - ransmissi Loa it- Tempi.,, : Junction Box IP6g gated ARM SMBB TechnologyHot 2.0 Technology ® Ratter light ?rapping and current collection to improve a+o The N-type module with Hot 2.0 technology has better E2S ■ SA dule mo power ontput and reliability. 2.0 reliability and tower LIDAYTID. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 Module Type JU426V-54111,4-11 PH:(631)779 7993 PID Resistance ++++ Enhanced Mechanical Load services@e2sys.com Licence-ME-52689 Ezce]lent Anti-PID performance guarantee ria ` Certified to withstand: wind Toed (2400 PascaU and srux optimized mass production process and materials za Ytuimu Poser (Pmax) 4251P 320pn (MASTER ELECTRICIAN) control. rune load (,AM P-0. 19y Licence- (SUFFOLK HOME IMPROVEMENT) Maximo Power current (lap) 13.13A 10.60A =` Solar Individual Short-rircuii Current (Ivc) 13.58A 10.W. Permit Package `® Durability Against Extreme Environmental Q c � C—L'" • • Conditions ® ` nlvE Operating Temperature( 'C) -4ttC--85r JOE CONSTANTIN-GUILD High salt m,st and:,mmnn is resistancc- Maximis series taae wall„g 25A 12.750KW Grid Tied Photovoltaic System le,'ratuty coefficients of P_ -0.29L/�C LINEAR PERFORNMME WARRANTY _- _ 400 LEGION AVE, Temperature coefficients of Ise 0.045%/C MATTITUCK,NY 11952 Rev Description Date 9DR f 25 Year Product Wa rranty A INITIAL DESIGN 3/23/2024 � At UPDATED DESIGN 3/27/2024 • JTC :,,,,Iyy�r radiance IOOOW/m ® Cell Temperature 25° C AM=1.5 A.2 UPDATED DESIGN 6/14/2024 * 30 Year Linear Power Warranty NOCT: 7�c Irradianre A(H)W,"m ® Ambient Temperature 20` C AM-I.5 Wind Speed I,n,'s OPPORTUNITY loll CONSTANTIN-GUILD } WAS PROJECT# NA E ? �. 40�b Annual De DATE DRAWN 6/14/2024 ear, gradation Over 30 years DRAWN BY E R y C2021 Jinko Solar Co., Ltd. All rights reserved. SHEET# PV-71.0 Specifications included in this datasheet are subject to change without notice. JRM125N-54HL4-B-F3C2-EN (IEC 2016) TITLE MODULE SPEC ENPHASE. ® I108MC Microinverter Commonly used module pairings' W 260-460 Module compatibility _ To meet compatibility,PV modules must be within the following max.input DC voltage and max.module Ia. Module compatibility can be checked at httDs://enDhase.com/installers/microinverters/calculator. MPPT voltage range V 25-45 THESE DRAWINGS ARE SUBJECT TO Operating range v 18-58 COPYRIGHT PROTECTION BY US LAW. Min./Max.start voltage V 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Max.input DC voltage v 60 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.continuous operating DC current A 14 Max.input DC short-circurt current A 25 Max.module I A 20 Current Ovwvohage class DC port - ll Renewables DC port backfeed current mA 0 = Engineering PV array configuration - Ungrounded array:no additional DC side protection required;AC side protection requires max 20 A per branch circuit CURRENT RENEWABLES ENGINEERING INC. Q 8 M C M i c ro i n ve rte r Peak output power VA 330 315 1760 RIVERSIDE AVE SUITE Easy to install Max.continuous output power VA 320 310 PHONE RIVERSIDE-1 92507 PHONE.(951)4OS1733 • Lightweight and compact withplug-and-playNominal d volt. (L-L) V 240,split-phase(L-L).1W 208,single-phase(L-U.120` WWW CRENG.CO Our newest IQS Series Microinverters are the industry'sfirst microgrid-forming`,software- grid � defined microinverters with split-phase power conversion capability to convert DC power to connectors Min./Max grid voltage, v 211-264 783-229 CONTRACTOR INFO AC power efficiently.The brain of the semiconductor-based microinveter is our proprietary Power line communication(PLC)between components Max-continuous output current 1application-specificapplication-specc integrated circuit(ASIC).which enables the microim erter to operate in grid-tied or off-grid modes.This chip is built in advanced 55-min technology with high-speed Faster installation with simple two-wire Nominal frequency Hz 60 digital logic and has superfast response times to changing loads and grid events,alleviating cabling Extended frequency range Hz 47-68 constraints on battery sizing for home energy systems. AC Short circuit fault current over three a N Arms 2-70 C 2 SYSU& High productivity and reliability cycles Enphase • Produces Power even when the grid is down* Max,units per 20 A(L-L)branch circuit` - 12 10 • More than one million cumulative hours of Total harmonic distortion <5 ELEMENT ENERGY LLC. testing 7470 SOUND AVENUE,MATTITUICK, Class ll double-insulated enclosure Overvoltage class AC port - g1 NEW YORK,11952 PH:(631)779 7993 Part of the Enphase Energy System, IQ8 Series Microinverters redefine Optimized for the latest high-powered PV AC port back feed current mA 18 services@e2sys.com IQB Series Microinverters integrate with reliability standards with more than one modules Licence-ME-52689 Power factor setting - 7.0 (MASTER ELECTRICIAN) the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Enphase App monitoring and analysis testing,enabling an industry-leading Microgrid-forming Grid-tied power factor(adjustable) - 0.85 leading...0.85lagging Licence-HI-67461 software. limited warranty of up to 25 years. (SUFFOLK HOME IMPROVEMENT) • Complies with the latest advanced grid Peak efficiency X 97.4 97.2 support CEC weighted efficiency x 97.0 96.5 Remote automatic updates for the latest grid Solar Individual requirements Nighttime power consumption mW 33 25 Permit Package Configurable to support a wide range of grid profiles Ambient temperature range -40°C to 65`C(-40`F to 149'F) J O E CO N STA N T I N-G U I L D Meets CA Rule 21(UL 1741-SA)and Relative humidity range 4%to 100%(condensing) Connect PV modules quickly and easily I08 Series Microinverters are UL Listed IEEE 1547:2018(UL 1741-56) to the 108 Series Microinverters that have as PV rapid shutdown equipment and DC connector type Staubli MC4 12.750KW Grid Tied integrated MC4 connectors. conforms with various regulations when NOTE: Dimensions(H-W•D);Weight 212 mm(8.3") 175 mm(6.9")+30.2 mm 0.2");11 kg(2.43 Ibs) installed according to the manufacturer's m Photovoltaic System instructions. toe Microveners cannot be mined together with Cooling Natural convection-no fans prevaus generations of Enphas,microlnvertem (107 Series.106 Senes.and so on)m the same Approved for wet locations;Pollution degree Yes;PD3 400 LEGION AVE, system. Enclosure Class 11double-insulated.corrosion-resistant polymeric enclosure MATTITUCK,NY 11952 10 Microimerters ship with def—ft settings that meet North America's IEEE 1547 interconnection Environ.category:UV exposure rating NEMA Type 6;outdoor Rev Description Dale standard requirements.Region-specific P adjustments may be requested by an Authority A INITIAL DESIGN 3/23/2024 Having Jurisdiction(AHJ)or utility representative. 'Meets UL 1741 only when installed with 10 System Controller 2 or 3. An 10 Gateway is requited to make these changes CA Rule 21(UL 1741-SA),UL 62109-1.IEEE 1547:2018(ILL 1741-SB),FCC Part 15 Class B.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01. A.1 UPDATED DESIGN 3/27/2024 during mstallatan. Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017.NEC 2020,and NEC 2023 section 690.12 and A2 UPDATED DESIGN 6/14/2024 O 2024 Enphase,Energy.All rights reserved.Enphase•the a And CC logos.Ia and oertain other marks listed M .- C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when Installed according to the manufacturer's instructions. __..----_._.._____-__..____-________--_________._.___._.__-- )OE CONSTA14TIN-GUILD (g No Nominal voltage age range ratio. httos://enphase.com/trademark-usaae�ultlelines are trademarb of Enphase Energy,Inc.m the U.S.and other countries. (2)Nominal voRapa range can be eatendad beyond nominal d required by the utltty. PROJECT# NA Data subject to change. IQBMC4AC4-OSH-00049-4A-EN-US-2024-02-09 (3)Limits may vary.Refer to local requirwreras to define the number of microinwrten per branch in your area IOBMC-MC4-DSH-00049-4.0-EN-US-2024-02-09 DATE DRAWN 6y14/2024 DRAWN BY E.R SHEET# PV-11.1 TITLE MICROINVERTER SPEC Enphase IQ Combiner 4/4C Data Sheet MODEL NUMBER Enphase Networking IQ Combiner 4(X-IQ-AM1 240-4) IQ Combiner with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%)Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat IQ Combiner 4C(X 10 AM1 240 4C) 10 Combiner 4C with Enphase 10 Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem - - - - ----- (CELLMODEM-M1-06 SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enphase The Enphase IQ Combiner 4/4C with Enphase the installation area)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not Included,order separately) IQ Gateway and integrated LTE-Ml cell ----- _- --- THESE DRAWINGS ARE SUBJECT TO Q Combiner 4/4 C Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-Mt-06-SP-05 with 5-year Sprint data plan for COPYRIGHT PROTECTION BY US LAW. modem(included only with IQ Combiner 4C) COMMS-CELLMODEM-MI-06 Ensemble sites REPRODUCTION IN ANY FORM IS CELLMODEM-M1-06-SP-05 -413 based LTE-Ml cellular modem with 5-year Sprint data plan EXPRESSLY FORBIDDEN WITHOUT PRIOR X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-M7-06-AT-05 4G based LTE-Ml cellular modem with 5-year AT&T data plan WRITTEN APPROVAL FROM CURRENT Circuit Breakers Supports Eaton BR210,BR215.BR220,BR230,BR240,BR250,and BR260 circuit breakers. RENEWABLES ENGINEERING INC. X-IQ-AM1-240-4C into a single enclosure and streamlines IQ BRK-IGA-2-240V Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A 2 240V Circuit breaker.2 pole,15A.Eaton BR215 microinverters and storage installations by BRK-20A-2P-240V Circuit breaker,2 pole.20A,Eaton BR220 BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR2158 with hold down kit support Current providing a consistent, pre-wired solution for BRK-20A-2P-24oV-B Circuit breaker,2 pole,20A,Eaton BR2208 with hold down kit support ion bridge pair),quantity-one pair0 EPLC- 1 Power line carrier(communication residential applications. It offers up to four -- -- - �XA SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4;4C Engineering 2-pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-Ot) E)ENPHASE i bUSbar assembly. CURRENT RENEWABLES XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner-4/4C ENGINEERING INC. • -----.-..------.------ -.-__..____—__ _ -__.__ X-10-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. 1760 CHICAGO AVE SUITE r ELECTRICAL SPECIFICATIONS J-13.RIVERSIDE CA 92507 PHONE(951)-405-1733 I Smart Rating Conti dUOUs duty WWW CRENG CO Includes IQ Gateway for communication and control System voltage 120/240 VAC,60 Hz CONTRACTOR INFO • Includes Enphase Mobile Connect cellular modem Eaton BR series busbar rating 125 A - ---- -- -- ---- - (CELLMODEM-MI-06-SP-05),included only with IQ Max continuous current rating 65 A Combiner 4C Max continuous current rating(input from PV/storage) 64A Includes solar shield to match Enphase IQ Battery Max fusercncuit rating(output) 90 A ® 01 Y _- aesthetics and deflect pheat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) C SYS Flexible networking supports Wi-Fi, -- - -- - --- _. - -----__ Max total branch circuit breaker rating(input) BOA of distributed generation(95A with IQ Gateway breaker included - I Ethernet,or cellular Envoy breaker 10A or 15A rating GE/Siemens/Eaton included Optional AC receptacle available for PLC bridge - - - -- - -- - -- --- - --- ELEMENT ENERGY LLC. Production metering CT 200 A solid core pre-installed and wired to I0 Gateway • Provides production metering and consumption 7470 SOUND AVENUE,MATTITUCK, i monitoring Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers NEW YORK,11952 MECHANICAL DATA PH:(631)779 7993 -- - _ _-- _ services@e2sys.com Simple Dimensions(WxHxD) 37.5 x 49.5 x 16.8 cm(14 75'x 19.5'x 6.63') Height is 21.06'(53 5 cm)with mounting brackets. Licence-ME-52689 weight 7 5 kg(16 5Ids) (MASTER ELECTRICIAN) Licence-HI-67461 Centered mounting brackets support single Ambient temperature range -401 Cto+46°C(-40°to 115°F) (SUFFOLK HOME IMPROVEMENT) stud mounting - • Supports bottom,back and side conduit entry Cooling Natural convection,plus heat shield Up to four 2-pole branch circuits for 240 VAC Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R polycarbonate construction Solar Individual __. plug-in breakers(not included) wire sizes 20 A to 50 A breaker inputs 14 to 4 AWG copper conductors Permit Package X-10-AMt 240.4C 80A total PV Or storage branch Circuits 60 A breaker branch input.4 to 1/0 AWG copper conductors i I Main lug combined output.10 to 2/0 AWG copper conductors • Neutral and ground'14to1/O copper conductors JOE CONSTANTIN-GUILD Always follow local code requirements for conductor sizing. Reliable Attitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS 12.750KW Grid Tied Durable NRTL-certified NEMAtype3Renclosure ----"�---_ ---- Photovoltaic System Integrated 1NfFi 802.1 tb/g/n t_ Five-year limited warranty _ —_ _ Two years labor reimbursement program coverage Cellular CELLMODEM-MI-06-SP-05,CELL MODEM-M1-06-AT-05(4G based LTE-M1 cellular modem) Note that an Enphase 400 LEGION AVE, included for both the IQ Combiner SKUs Mobile Connect cellularmodem is required for all Ensemble installations UL listed Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) MATTITU CK,NY 11952 - J COMPLIANCE Rev Description Date Compliance,10 Combiner UL 1741,CAN/CSA C22.2 No.107.1.47 CFR,Part 15.Class B,ICES 003 Production metering.ANSI C12.20 accuracy class 0.5(PV production) A INITIAL DESIGN 323/2024 Consumption metering.accuracy class 2.5 A UPDATED DESIGN 3/27/2D24 X-4K*QAW-2 Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 A 2 UPDATED DESIGN 6/14/2024 lrM OPPORTUNITY JOECONSTANTIN-GUILD ENPHASE To learn more about Enphase offerings,visit gnphaga,CO r �/ To learn more about Enphase offerings,visit�hase.com u EN P H AS E PROJECT# NA C4 2022 Enphase Energy.All rights reserved Enphase.the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of DATE DRAWN 6/14/2024 Enphase Energy.Inc.Data subject to change.02-14-2022 DRANK BY E.R SHEET# PV-11.2 TITLE COMBINER SPEC /lr. IRONRIDGE XR Rails Family XR Rail' Family The XR RaiOr Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads,while minimizing material costs. Depending on your location,there is an XR Rail'P'to match. Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years. THESE DRAWINGS ARE SUBJECT TO but the worst storms in 40 years. High winds capable of �` - COPYRIGHT PROTECTION BY US LAW ripping panels from a roof, and snowfalls weighing i REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR enough to buckle a panel frame. ` \• ENEWA APPROVAL FROM RING R ENT INC XR RailsJ are the structural backbone preventing these results.They resist uplift, XR10 XR100 XR1000 protect against buckling and safely Current XR10 is a sleek,low-profile mounting XR100 Is a residential and commercial XR1000 is a heavyweight among and efficiently transfer loads into the rail designed for regions with light or mounting rail It supports a range of solar mounting rails It's built to handle building structure.Their superior no snow It achieves spans up to 6 feet, wind and snow conditions while also extreme climates and spans up to 12 n spanning capability requires fewer EnQ i ne e'InQ while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. roof attachments, reducing the - 6 spanning capability 10'spanning capability 12'spanning capability CURRENT RENEWABLES number of roof penetrations Moderate load capability Heavy load capability Extreme load capability p Clear&black anodized finish Clear&black anodized finish Clear anodized finish ENGINEERING INC. and the amount Of 1760 CHICAGO AVE SUITE • Internal splices available Internal splices available Internal splices available J-13.RIVERSIDE CA 92507 installation time. -�`'- PHONE(951)-405-1733 WWW.CRENG.CO Rail Selection CONTRACTOR INFO t The table below was prepared in compliance with applicable engineering codes and standards.`Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft Visit IronRidge.com for detailed certification letters. ® 01 EZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, Force-Stabilizing Curve 90 NEW YORK,11952 Sloped roofs generate both vertical and lateral PH:(631)779 7993 forces on mounting rails which can cause them to Norte 120 services@e2sys.com bend and twist.The Curved shape of XR Railsa Licence-ME-52689 is specialty designed to increase strength in both 140 XR10 XR100 XR1000 (MASTER ELECTRICIAN) directions while resisting the twisting.This unique Licence-HI-67461 feature ensures greater security during extreme 160 (SUFFOLK HOME IMPROVEMENT) weather and a longer system lifetime. 90-- Solar Individual �s 20 140 Permit Package �\ 10 160 JOE CONSTANTIN-GUILD 30 90 12.750KW Grid Tied r 160 Photovoltaic System Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 400 LEGION AVE, XR Rails' are IronRidge"otters All XR Rails"are made of 6000-serves 40 MATTITUCK,NY 11952 Compatible with a range of tilt leg I aluminum alloy.then protected with an 160 FlashFoot'^and options for flat I anodized finish.Anodizing prevents surface Rev Description Date other pitched roof roof mounting and structural corrosion,while also providing 80 160 A INITIAL DESIGN 3/z3/zoza attachments. applications. a more attractive appearance 1 160 A 1 UPDATED DESIGN 3/2 712 0 2 4 --- -- - - ------------ -------------- — -- -- — ----- A UPDATED DESIGN 6/14/2024 -Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. OPPORTUNITY lOE CO NSTANTIN-GUILD PROJECT# NA r ;r r DATE DRAWN 6/14/2024 DRAWN BY ER SHEET# PV-11.3 TITLE RAIL SPEC .+'rl IRONRIDGE QuickMountt ® Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home. solar attachments THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. • • • COPYRIGHT PROTECTION BY US LAW. r. Due t0 recent innovations. many asphalt Shingles REPRODUCTION IN ANY FORM IS _ EXPRESSLY FORBIDDEN WITHOUT PRIOR have bonded courses.A mount that protects without WRITTEN APPROVAL FROM CURRENT --- the need to pry shingles can really speed things up. RENEWABLES ENGINEERING INC "-�"""-" • • • • i Halo UltraGrip'(HUG� lip ') is here to respect the roof. Current Its Halo is a cast-aluminum barrier that encases the UltraGrip. our industrial-grade.foam-and-mastic 0 taf seal.This allows HUG to accelerate the installation Engineering process and provide the utmost in waterproofing _ Hit the rafter?Good to go! Miss the rafter?Try it protection. Give your roof a HUG.' Still no luck?Install the CURRENT RENEWABLES When you find a rafter,you can move on. Place another screw to the left or right.It If more than 3 screws miss the rafter. ,D Structural Screws d_ck ENGINEERING INC. mount it. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA92507 PHONE-(951)-405-1733 WWW.CRENG.CO Multi-Tiered Waterproofing HUG'utilizes a mule-tiered stack of CONTRACTOR INFO components to provide revolutionary Trusted Strength & Less Hassle waterproofing protection.The Halo cast- aluminum,raised-perimeter foundation surrounds the UltraGrip base-a foam- Structural capacities of HUGS were reviewed in deed mastic seal combination that many load directions, with racking rail running prevents water intrusion by adhering •-- sealing with the shingle surface cross-slope or up-slope in relation to roof pitch. CZSYS8 traGrip'"is part For further details, see the HUG certification QuickMount° letters for attachingto rafters and decking. pwuuct line. - - _—_- _ g ELEMENT ENERGY LLC. •—•' --" .. _ _ 17470 SOUND AVENUE,MATTITUCK, - - ___-- - - - IronRldge designed the HUG, in combination NEW YORK,11952 PH:(631)779 7993 UltraGrip Seal Technology: with the RD Structural Screw to streamline services@e2sys.com HUG UltraGrip utilizes a state-of- installs, which means the following: Licence-ME-52689 art seal design that uses a unique, (MASTER ELECTRICIAN) foam-and-mastic combination.The;. + Licence-HI-67461 foam-backed adhesive proves an, No prying shingles (SUFFOLK HOME IMPROVEMENT) entirely new flashing system that No roof nail interference conforms and adheres to every n 25-Year Warranty and cranny of composition shing Product guaranteed tree No pilot holes necessary Solar Individual tilling gaps and shingle step-downs (up to tie'in height). of impairing defects. No sealant(in most cases) • No butyl shims needed Permit Package JOE CONSTANTIN-GUILD Attachment Structural Water Seal UL 1 DesignLoading 12.750KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rafter&Deck Mounting Options The rafter mounted Parts are designed HUG passed both Systems conform to Mount HUG' to the roof rafters.the root Rev Deecnption Date deck or both with our custom-en-engineered HUG has been and certified for the UL 441 Section UL 2703 mechanical •� • f►� g i A INITIAL DESIGN 323/2024 RD(rafter-or-deck)Structural Screw The RD tested and rated to compliance with 27"Rain Test"and and bonding ETb Triple Rated&Certified Structural Screw anchors HUG to the roof support 1004(Ibs)of the International TAS 100(A)-95 requirements. See UPDATED DESIGN 3/27/2024 to Respect the Roof- with an EPDM sealing washer,completing A 2 UPDATED DESIGN 6/14/2024 UL27o3.441 (27) the stack of waterproofing barriers.See uplift and 368 (Ibs) Building Code & "Wind Driven Rain Flush Mount Manual OPPORTUNITY ,OE CONSTANTIN-GUILD Intertek TAS 100(A)-95 backside for more installation Information. of lateral load. ASCE/SEI-7. Test"by Intertek. i for more info. PROJECT a NA DATE DRAWN 6/14/2024 j- DRAWN BY E.R rs.compatentSHEET# PV-11 4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. Hayward,CA 94545 28357 Industrial Blvd. 1-800-227-9523 //,I IRON RI DGE OHayward.-9 94545 RON RI DGE IronRidge.com IronRidge om3 Attn:Sean McDonald,CEO,IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following: Date:November 1611,2022 P 1 P Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1 The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1 5-1 2. Winds speed shall conform to ASCE 7-16 Fig 26.5-1 B(for Risk Category II and applicable state&local THESE DRAWINGS ARE SUBJECT US To P 9 9 Y ) PP COPYRIGHT PROTECTION BY US LAW. This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The county/city amendments to the IBC. No special wind topographic features are included and both topographic REPRODUCTION IN ANY FORM IS contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(K,)and wind ground elevation factor(Ke)are taken as 1.0. EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape RENEWABLEs ENGINEERING INC orientation and set parallel to the underlying roof surface PV modules are supported by extruded aluminum XR Rails 3 Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig. 7.2-1 and applicable state&local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof format of a flat roof snow, it shall first be converted to a ground snow following the local building code/ attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables No special snow conditions are considered Current that is fastened to the underlying roof structure Assembly details of a typical Flush Mount Installation and its core including unbalanced,drifting,sliding,retention,or ponding snow No rain-on-snow surcharge load is n components are shown in Exhibit EX-0015 considered.The span tables do not apply to buildings which are intentionally kept below freezing,kept just Engineering above freezing,or unheated T The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being CURRENT RENEWABLES listed below.for the load conditions and configurations tabulated in the attached span tables ENGINEERING INC. a For round snow no greater than 42 sf.SS 5 2 D for Site Class A,B,C, &D. J-13 RIVERSICHICAGDE AVE SUITE2507 O 9 9 P g J-13.RIVERSIDE CA 92507 • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Ss<_1.0g for Site Class A. B,C,&D. PHONE(951)d05-1733 WWW.CRENG.CO • 2021 International Building Code(IBC-2021) (c)For ground snow between 42 and 65psf:Ss:5 1.5g for Site Class A, B,C,&D. CONTRACTOR INFO • 2022 California Building Code(CBC-2022) • 2020 Aluminum Design Manual(ADM-2020) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in --�-- -- • Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GC,). Roof zones comprising each group along with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. a Ig The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6 The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall the respective loads and configurations listed.covering wind exposure categories B,C, &D, roof zones provided in be the lesser of the following two conditions 40%of the allowable span provided for the respective load ��SYS ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8`to 45' The tabulated spans are applicable when the &configuration condition from the span tables. or 36". 1 following conditions are met. 7 Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over ELEMENT ENERGY LLC. a minimum of three spans. 7470 SOUND AVENUE,MATTITUCK, 1. San is the distance between two adjacent roof attachment points measured at the center of the NEW PORK,11952 P J P ( PH:(637)779 7993 attachment fastener). 8. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: services@e2sys.com Licence-ME-52689 a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans, or the outer 2/3 of end spans. (MASTER ELECTRICIAN) 2 Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system) Spans are calculated b) BOSS Splice can be installed at any location within a span. Licence-HI-67461 based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. (SUFFOLK HOME IMPROVEMENT) 9 Shaded cells of the span tables Indicate conditionsinwhich UFO Mid Clamp connection capacity is exceeded. If 3 The underlying roof slope, measured between the roof surface and horizontal plane,is 8°to 45' such conditions are encountered contact techsupport@/ronndge.com. Solar Individual Permit Package 4. The mean roof height.defined as the average of the roof eave height and the roof ridge height measured from grade,does not exceed 30 feet. JOE CONSTANTIN-GUILD 5 A clearance from the underside of the array to the roof surface of 2' minimum shall be provided and the 12.750KW Grid Tied height of the array.the distance from the module top surface to the roof surface(defined as h2).shall not Photovoltaic System exceed 10 400 LEGION AVE, 6. Module length and area shall not exceed the maximum values listed on the respective span tables MATTITUCK,NY 11952 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Rev Description Date A INITIAL DESIGN 3/23/2024 Mount Installation Manual and other applicable standards for the general roof construction practice A, UPDATED DESIGN 1 3/27/2024 A.2 UPDATED DESIGN 1 6/14/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD 2022 IronRidge.Inc. CA Flush Mount System Certification Letter-1 J 2022 IronRidge.Inc. CA Flush Mount System Certification Letter-2 PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY E.R SHEET# PV-11.5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. f&L I RON RI DGE Hayward, 94545 I RON RI DGE Hayward, 94545 1-800-227-9-9523 1-800-227-9-9523 IronRidge.com IronRidge com 10. Systems using CAMO module clamps shall be installed with the following guidance: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67.5",CAMO consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting clamps shall not be installed In regions that experience ground snow loads of 70psf and greater.Such members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the scenarios are shown by asterisks in the applicable span tables aforementioned system components in regards to the applied or resultant loads of any chosen array configuration This THESE DRAWINGS ARE SUBJECT TO b) CAMO will function within a modules design load ratings Be sure the specific module being used with letter certifies the IronRidge products referenced within this document and provides no determination of the project COPYRIGHT PROTECTION BY US LAW CAMO meets the dimensional requirements shown in the figure below and that the module selected is specific conditions including site loads,building profile,&roof zones,which remain the responsibility of the installer or REPRODUCTION IN ANY FORM IS suitable for the environmental conditions of a articular project. system designer EXPRESSLY FORBIDDEN WITHOUT PRIOR P P J 9 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. MoOuie,Gloss/CeNs Current Sincerely, QPoFESS7oti Digitally signed - Gx� �Fy f — EnQlneerlrg Rome Compal3ilirty. Q) i ; by Gang X u a n JT x=1.2-2.2 mm (7 NO.6504r^ CURREQ M Date. 2022.1 1 .18 ENGINEERING LES Y=tS-40 mm 6 � ENGINEERING INC. 1760 CHICAGO AVE SUITE X ".1O� 10.55.51 08'00' J-13,RIVERSIDE CA 92507 r • . _ PHONE:(951)-405-1733 WWW.CRENG.CO ------------ . T Gang Xuan,SE Figure 1:CAMO Modulr Frame DimensiorW Requlre•,,e, CONTRACTOR INFO Senior Structural Engineer Span values for Exposed and Edge module conditions,as defined below,are included in the attached span tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge ® —.a modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; 01 (2)The span value determined by site wind speed and ground snow load.Additionally, irrespective of the lesser span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage EZSYS° limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 1. Exposed Module conditions: NEW YORK,11952 PH:(631)779 7993 services@e2sys.com A module is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free Licence-ME-52689 (MASTER ELECTRICIAN) edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge,rake,or Licence-HI-67461 hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from its free edge to any (SUFFOLK HOME IMPROVEMENT) other adjacent array or panel is greater than 4 feet. The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed Solar IndividualPermit Package Modules. JOE CONSTANTIN-GUILD 2. Edge Module conditions: 12.750KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave. ridge,rake,or hip)is less than 2 times the height of the array(2h2) where h2 is measured from the roof surface to the top surface of the module. 400 LEGION AVE, The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. MATTITUCK,NY 11952 Additionally,if the roof edge is the I or ridge,only the rail nearest to that roof edge shall be considered Pev Description Date or this span adjustment. H INITIAL DESIGN 3/23/2024 A 1 UPDATED DESIGN 3/27/2024 A2 UPDATED DESIGN 6/14/2024 OPPORTUNITY JOE CONSTANTIN-GUILD C 2022 IronRidge.Inc. CA Flush Mount System Certification Letter-3 C 2022 IronRidge.Inc. CA Flush Mount System Certification Letter-4 PROJECT# NA DATE DRAWN 6/14/2024 DRAWN BY ER SHEET# PV-11 6 TITLE CERTIFICATION