Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50269-Z
OUF 1 Town of Southold 10/5/2024 a y _ P.O.Box 1179 o _ 53095 Main Rd ��j�l yao Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45634 Date: 10/5/2024 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 605 Circle Dr,East Marion SCTM#: 473889 Sec/Block/Lot: 21.-3-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/15/2023 pursuant to which Building Permit No. 50269 dated 1/29/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations and additions, including outdoor shower and landings,to existing single family dwelling with unfinished basement as applied for. The certificate is issued to 605 Circle Dr LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50269 9/12/2024 PLUMBERS CERTIFICATION DATED 6/21/2024 amaritan Plumbing c Au or ze gnature �O�SUFent�.�o TOWN OF SOUTHOLD ay BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • �'� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 5026.9 Date: 1/29/2024 Permission is hereby granted to: Bulis, Maria 10 Glenville St Unit 210 Greenwich, CT 06831 To: construct alterations (inclusive.of outdoor shower) to existing single-family dwelling as applied for. At premises located at: 605 Circle Dr, East-Marion SCTM #473889 Sec/Block/Lot# 21.-3-7 Pursuant to application dated 12/15/2023 and approved by the Building Inspector. To expire on 7/30/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $367.00 CO-ALTERATION TO DWELLING $100.00 Total: $467.00 Building Inspector pf SOUT��I Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G . Q Southold,NY 11971-0959 ��ly �o sean.devlinitown.southold.ny.us COUMy,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Maria Bulis Address: 605 Circle Dr City:East Marion st: NY zip: 11939 Building Permit#: 50269 Section: 21 Block: 3 Lot: 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: BWO Electric License No: 64604ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor X Pool New X Renovation X 2nd Floor Hot Tub Addition Survey X Attic X Garage INVENTORY Service 1 ph X Heat Duplec Recpt 2$ Ceiling Fixtures $ Bath Exhaust Fan 2 Service 3 ph Hot Water 30A GFCI Recpt 12 Wall Fixtures 5 Smoke Detectors 3 Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 20 CO Detectors Sub Panel A/C Blower 1 Range Recpt 40A Ceiling Fan 4 Combo Smoke/CO 3 Transfer Switch UC Lights $' Dryer Recpt 30A Emergency Strobe Heat Detectors Disconnect Switches 26 4'LED Exit Fixtures [I Sump Pump Other Equipment: Fridge, Oven, DW, Micro, MiniSplit, W/D, 200A Panel 40 Circuits/ 31 Used, Leviton 200A Metermain Panel 8 Circuits / 0 Used Notes: One Story w/ Unfinished Basement Inspector Signature: Date: September 12, 2024 S.Devlin-Cent Electrical Compliance Form Copy y o�oS�fFoc,��o r Town Hall Annex hy► >Gy i� Telephone(631) 765-1802 54375 Main Road P. O. Box 1179 ti Southold, NY 11971-0959 0 , O BUILDING DEPARTMENT L5 D TOWN OF SOUTHOLD JUN 2 6 2024 CERTIFICATION BU,I9ING DEFT T TQ '.F SOIL ��/—; y Date: Building Permit No. S 0 ko Owner: EZ1 N �- (Please print) Plumber: S 0IM A 8 0 (Please print) �l 6 DIS - n I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. zIDLfl� -7 919 �] (Plumbers Signature) Sworn to before me this t/ I THOMAS J.McCARTHY Notary Public.State of New York day of 20 Suffolk County•No.5004190 COMM1661 t Expires November 23,i0 o„� Notary Public, v County 1 rag so �u7 OF SO BUI 1 l� - Cf 4WN UTHOLD LDING DEPT. cou 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION-2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]' FIRE:RESISTANTPENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) (. ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: (>ef � G A�_ DATE INSPECTOR so # .* ,-TOWN OFSOUTHOLD BUILDING DEPT. louff 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION=- [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �v -}ter' U N �1• �F� jrc_v)4_d_"' �r /, of !� l2 2 Ll DATE INSPECTOR OF SO(/Tyolo # # . TOWN OF SOUTHOLD BUILDING DEPT. • ao coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ]' ROUGH PLBG. [." ] FOUNDATION.2ND [ ] 1 LATION/CAULKING [ ] FRAMING /STRAPPING [ .FINAL [ ] -FIREPLACE & CHIMNEY ' [ 'I FIRE SAFETY INSPECTION [. ] FIRE'RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [: ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: r DATE 10 ti0 INSPECTOR LaChapelle Architecture Observations: Non-load bearing framing at new bedroom 2 was required,and observed to be in conformance with applicable portions of NYS Building Code. Rough plumbing observed was in conformance with applicable portions of NYS Building Code. The approved documents call for existing ceiling and wall cavities exposed during construction to be filled with insulation.This is in conformance R503.1.1—i.e.existing ceiling and wall cavities exposed during construction must be filled with insulation,though the values for new construction need not be met if energy use of the structure is not increased. R-15 mineral wool insulation(>R3/inch)was observed installed in exposed wall and ceiling cavities in conformance with the approved drawings and with code.Installation was workmanlike and continuous. Cavities were completely filled. 4 Fig. 1—R15 mineral wool insulation installed in evistin_g ivall stud cavities, bedroom 1 Firestopping was observed at penetrations from the basement to the first floor,though several abandoned plumbing penetrations remain open (see Fig.3). 4 Open penetrations must be sealed;provide photos P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com p. 2/5 LaChapelle Architecture JUN 2 0 9024 BL r . Fib. 2-firestopping Fig. 3—open bole in floor P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com p 3 LaChapelle Architecture Front steps must have nosing between 3/4"and 1-1/4"deep. Jur+ -,)94 4 Fix front stair nosing,confirm at final inspection d a, V g. 4—flnnl'.flail'iiosigo P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com p.4/5 LaChapelle Architecture Windows were observed to meet U-factor and S1IGC maximums in the 2020 Energy Conservation Code of New York State,and to meet the specification in the approved drawings. Thank you for tK�z selecting quality Andersen products ANDERSEN t 1, '- . _ n.?81-59 0 0.55 S—windows, U=0.32 or better.SH(1 . ED AR ��ACHgA -end report- CCi �P� R- ';�' n OF NE`N P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com P. 5/5 ,SO 2 co9 LaChapelle Architecture : FC20 V FI June 131h,2024 J U N 2 0 2024 � Inspection Report BUILDING DEPT. TOWN ;F SOUT lsal Project: 605 Circle Drive East Marion,NY 119739 Inspection Type: (Tbose selected for this job are in bold, those inspeaed on ibis date are checked) ❑ Footing reinforcement or pier excavation prior to pour ❑ Footing keyway with foundation wall reinforcement ❑ Foundation before backfill ❑ Foundation damp proofing ® Framing,tie down/strapping and plumbing ❑ Underground plumbing R1 Perimeter insulation ❑ Rough electric ® Rough plumbing ® Insulation and caulking ❑ Solid fuel-burning heating appliances,chimneys,flues or gas vents N Energy Code compliance ❑ Final inspection Inspection date: June 5th,2022 Observations by: Jake LaChapelle Executive Summary: Framing,rough plumbing,insulation,caulking,and new windows and doors observed were found to be in conformance with applicable code requirements and the documents. Follow up inspection needed? Final electrical and final. P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@lachapellearctiitec=e.com lachapellearchitecture.com p.1/5 FIELD INSPECTION REPORT DATE COMMENTS c 4 � N � FOUNDATION (IST) ------------------------------------ FOUNDATION (2ND) N � z 0 ROUGH FRAMING& PLUMBING `may J C'd LA d r INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 5 22 C cdrtL 4 ci O z 1 -Q- e.( cd ly NO �z x e b H f 014 TOWN OF SOUTHOLD—BUILDING DEPARTIMM Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631)765-9502 https://www.southoldtownnv.eov Date Rmelved APPLICATION FOR BUILDING PERMIT For office Use Only DEC 1 5 2023 PERMIT NO. 56 � Building Inspector: Applications and forms must be filled out in their entirety.Incomplete J applications will not be accepted. Where the Applicant is not the owner,an " Owner's Authorization form(Page 2)shall be completed. Date:December 12th,2023 r OWNER(S)OF PROPERTY: Name:Eric Bulis SCTM#1000-21.-3-7 Project Address:605 Circle Drive East Marion, NY 11939 Phone#:(917) 886-5367 1 Email: Mailing Address:69 Riverdale Ave, Unit 603, Greenwich, CT 06831 CONTACT PERSON: Name:Jake LaChapelle Mailing Address:PO Box 1251, Mattituck, NY 11952 Phone#:(646)251-5058 Email:jake@lachapellearchitecture.com DESIGN PROFESSIONAL INFORMATION: ; Name:Jake LaChapelle AIA; LaChapelle Architecture PLLC Mailing Address:PO Box 1251, Mattituck, NY 11952 Phone#:(646) 251-5058 Email:jake@lachapellearchitecture.com CONTRACTOR INFORMATION: Name:Charlie Thorp Mailing Address:'p.0. Box 396, East Marion, NY 11939 Phone#:(631) 926-4615 1Email:n/a DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure OAddition ®Alteration ❑Repair ODemolition Estimated Cost of Project: ❑Other $100.000 Will the lot be re-graded? OYes @No Will excess fill be removed from premises? OYes BNo PROPERTY INFORMATION Existing use of property:Seasonal/reSldential Intended use of property:no change Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 Med-Density Residential this property? Dyes ®No IF YES,PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,Newyork and other applicable laws,Ordinances or Regulations,for the construction of buildings, . additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In buildings)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print m Jake LaChapelle AIA ®Authorized Agent Downer Signature of Applicant- Date: CONNIE D. BUNCH Notary Public,State of New York (( STATE OF NEW YORK) No.01 BU6185050 Qualified in Suffolk County SS:COUNTY OF folk Commission Expires April 14,2�c � Jake LaChapelle AIA being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn �,before me this � L l `day of .20� MD Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I Eric Bulls residing at 69 Riverdale Ave - Unit 603 Greenwich, CT 06831 do hereby authorize Jake LaChapelle AIA to apply on my behalf to the Town of Southold Building Department for approval as described herein. J��1 � f23 wnei's Signature Date Eric Bulls Print Owner's Name 2 *' guFFA�kZN BUILDING DEPARTMENT- Electrical Inspector V'- , TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road --PO,Box 1179 Southold, New York 11971-0959 4,� i` �'� y Telephone (631) 765-1802 - FAX (631) 765-9502 ' rogerr(D-southoldtownny.gov - seand(cDsoutholdtownny.g'ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: c;2 i �az�.4/ Company Name: WO , Electrician's Name: 1�V-v c,E License No.: (,a p cl Elec. email: Elec. Phone No: (3( 8;3q ERrrequest an email copy of Certificate of'Compliance Elec. Address.: 3©a & `err► JOB SITE INFORMATION (All Information Required) Name: Lcm 0 C ,iq fAr"A1\/ \r us— Address: cK.G�� Cross Street: ¢1 v gyp. V IC;W Phone No.: g 17 to -5' Bldg.Permit#: 50 a Le dc� email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): -rD-rRf' C7"V Z r4.V%d R.bW 1QZL N-ew 4o0 5E2.VI C.= Square Footage: co Circle All That Apply: Is job ready for inspection?: YES O'NOough In Final Do you need a Temp Certificate?: YES F-] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service Fire ReconnectOFlood Reconnect OService Reconnect Underground QOverhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ire c-- ► 0 to PERMIT# Address: Switches Outlets GFI's Surface �� I Sconces H H's UC Lts �il Fridge HW POOL Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Water Bond Carbon Micro GrbDis Lights Heat Pucks ERV - HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cookt p I`Jlinisplit I Blower AC AH I So)' Hood Blower Service Amps '2� Have Di s e d Sub Amps Have Used Commentso (�Cf /� � �1/'� y� � r APPR0 ED AS NOTED oA P.# _ Lt 8IN.G FEE BY: •�1�t PLl1MEIPJG 11VHS7E• ;� .:. NOTIFY BUILDING DEPARTMENT AT r ` :`WATER LINES NEED .: C4RF CO,UERING N.. 631-765-1802 8AM TO 4PM FOR THE •.• : FOLLOWING INSPECTION& 1. FOUNDATION-TWO NE0 1PED FOR POURED CONCRE')'t_ 2. ROUGH-FRAMING&F LU,vif'INIG 3. INSULATION 4 FINAL-CONSTRUCTION MUST PLUMBER CERTIFICATIOI. BE COMPLETE FOR C.O. ON LEAD-CONTENT BEFOPL ALL CONSTRUCTION SHALL MEET THE CERTIFICATE OF OCCUPAN" REQUIREMENTS OF THE CODES OF NEW SOLDER USED IN WA TEA YORK STATE. NOT RESPONSIBLE FOR -DESIGN OR CONSTRUCTON ERRORS SUPPLY SYSTEM CAN EXCEED 2110 OF 1% L EA U COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLD TO ZBA ELECTRICAL SOUTHOLD T N PLANNING BOARD INSPECTION REQUIRED SOLON OWN TRUSTEES VS.D SO LD HPC S All exterior lighting installed, replaced or repaired shall conform OCCUPANCY OR to Chapter 172 USE IS UNLAWFUL of the Town Code WITHOUT CERTIFICAT' OF OCCUPANCY ) • P„ e T i I GEROSA/BULIS RESIDENCE DRAWING LIST 605 CIRCLE DRIVE 605 CIRCLE DRIVE EAST MARION,NY 11939 A1.00 DRAWING LIST, SYMBOLS,ABBREVIATIONS, &INSPECTIONS A2.00 NOTES EAST M A R I O N, N Y A3.00 ENERGY CODE COMPLIANCE A4.00 SITE PLAN t1 A5.00 BASEMENT PLAN TRUE p O d oq SCTM#-1000-21.-3-7 A6.00 GROUND FLOOR PLAN- DEMOLITION NORTH A7.00 GROUND FLOOR PLAN -CONSTRUCTION oa7a" A8.00 GROUND FLOOR RCP &ELECTRIC PLAN ® oA9.00 NORTH&EAST ELEVATIONS PROJECT A10.00 SOUTH &WEST ELEVATIONS (3o3R84°) F,P Q A11.00 INTERIOR ELEVATIONS Al2.00 DETAILS TAX MAP SCTM#4000-21.-3-7 # ISSUE/REVISION DATE NOTE: DO NOT SCALE FROM DRAWINGS .00 FILING SET 12.12.2023 SYMBOLS REGULATORY NOTES ABBREVIATIONS DRAWN BY.J.LACHAPELLE 1. THIS APPLICATION FOR BUILDING PERMIT IS FILED WITH THE A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY:J.LACHAPELLE LEVEL TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN 1X'x 17"SHEET O WINDOW THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAY BE PRINTED NOT TO SCALE A EL. +31'-3" HT HEIGHT `--ELEVATION ABOVE 0'-0" 2. THE CONTROLLING CODE IS THE 2020 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC ODOOR YORK STATE AND THE 2020 ENERGY CONSERVATION CODE OF P.O.Box 1251 NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL Mattituck,NY 11952 1 ELEVATION NUMBER C.J. CONSTRUCTION JOINT MTL METAL (646)251-5058 jake@lachapellearchitecture.com 1O PARTITION TYPE A6 SHEET NUMBER 3. REFERENCE HEREIN TO 'BC'SHOULD BE CONSTRUED TO MEAN CLG CEILING THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CMU CONCRETE MASONRY UNIT PTD PAINTED CONIC CONCRETE 4. THIS SINGLE-FAMILY HOME OCCUPANCY CLASSIFICATION IS CONT. CONTINUOUS RCP REFLECTED CEILING PLAN A3 1 DETAIL NUMBER RESIDENTIAL GROUP R-3 UNDER BC CHAPTER 3. CONT'D CONTINUED R.O. ROUGH OPENING �REO ARC A4 SHEET NUMBER 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE V(B) DBL DOUBLE O.C. ON CENTERF<< n (UNPROTECTED WOOD FRAME) UNDER BC TABLES 601 AND 602. D.H. DOUBLE HUNG 1 -1 DIM. DIMENSION SIM. SIMILAR 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED DIA. DIAMETER S.S. STAINLESS STEEL _I J HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS,CODES, DISC. DISCONTINUOUS STL. STEEL AND REGULATIONS. DWG DRAWING ;4�T�0 03393� p``L STAIR DIRECTION ELEC. ELECTRIC TYP. TYPICAL f OF NON LABELS INSPECTIONS E ENGINEER V.I.F. VERIFY IN FIELD �T THERMOSTAT � '� EQ.Q. EQUAL TIIIODNAWIN05mIN5fRUMFAITOFSFHYICEmONEMALY9THEPROPERf1OiL1CNAPELLE UPDN EXIST. EXISTING W/ WITH ARCHREC HE PLLC flE0A0.0 ESSOFYAE XEflT 2PflmEC fOfl WH0HRI5 PNEPARFDR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE EUDU ED.noamcEs,uTEwnaxs an DE enoxs Ma+DEMmEExcEV Dr ACWJE LE ANCHREMMOPLLC SPDPE .MAT NOTEEIAEO[ROTHFNPANOFSPoNOnIPAPNOIECRi, W WATER DETECTOR WD. WOOD iOfl ADDRION TOlH15 PNOIFCf Or OTIffA PAH1IEE,OF1 FOfl COMPIEiIONOFTNISPNOIER BY anrtN vaRRFs.xnHaR Tx E xwRFn wFaErrt a FAnuPELLE aflcxnEeru�vuc. REQUIREMENTS OF BCNYS 1704&1705. OCOPYgDHT]DtE{ACIWPELIEa1iCMTEDTDNEPtm FL FLOOR WWM WELDED WIRE MESH SC SMOKE+CARBON MONOXIDE DETECTOR PERIMETER INSULATION DRAWING LIST, SMOKE AND CO DETECTORS SHALL COMPLY ROUGH ELECTRIC ABBREVIATIONS, WITH UL 268;7th ADDITION INSULATION AND CAULKING SYMBOLS,& NOTES CENTER LINE ENERGY CODE COMPLIANCE SCOPE OF WORK FINAL SHEET NO: BREAK LINE THE GENERAL INTENT OF THE WORK IS RENOVATION OF THIS EXISTING SINGLE-FAMILY HOUSE. NO CHANGE OF USE OR OCCUPANCY IS AlmOO PROPOSED. SHEET 1 OF 12 'GENERAL NOTES GENERAL NOTES PVC TRIM NOTES GEROSA/BULIS 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 11. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED 1. ALL EXTERIOR TRIM TO BE PVC,1'OR GREATER NOMINAL RESIDENCE ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND THICKNESS. 605 CIRCLE DRIVE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK.ALL EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE EAST MARION,NY 11939 PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY INSPECTOR. 2. USE 'CORTEX' HIDDEN FASTENING SYSTEM BY TIMBERTECH w/ PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE PLUGS AND#8 SCREWS;SELECT SCREW LENGTH APPROPRIATE FOR FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL 12. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT TRIM THICKNESS AND SUBSTRATE. WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY)AND SYSTEMATIC MANNER. INSURANCE REQUIREMENTS. 3. ANTICIPATE THERMAL MOVEMENT IN USE OF PVC TRIM; PROVIDE a JOINTS FOR EXPANSION AND CONTRACTION,AS WELL AS NORTH 2. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE 13. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE SUFFICIENT FASTENING TO AVOID WARPING AND OIL-CANNING IN ° a BUILDING CODES,ALL WORK MUST CONFORM TO FIRE BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER WARM WEATHER. ® DEPARTMENT REGULATIONS,UTILITY COMPANY AND RECEIPT OF WRITTEN CONSENT. PROJECT REQUIREMENTS,AND BEST TRADE PRACTICES. 4. USE MINIMUM (2) FASTENERS EVERY 16- FOR TRIM BOARDS UNDER (sea°) 0 9 14. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE 8- IN WIDTH AND(3) FASTENERS EVERY 16' FOR TRIM BOARDS 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS OVER 8' IN WIDTH. FASTENERS MUST PENETRATE SUBSTRATE 1 ZB TAXMAPSCTM#-1000-21.37 FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY MINIMUM. # ISSUE/REVISION DATE DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. TO THE ARCHITECT. 5. GLUE TRIM TO SUBSTRATE WHENEVER PRACTICAL, USING LIQUID .00 FILING SET 12.12.2023 15. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IN NAILS OR SIMILAR ADHESIVE. 4. CONTRACTOR SHALL TAKE THEIR-OWN DIMENSIONS AND FIELD ADVANCE TO PROVIDE FOUNDATION SURVEY AS SOON AS VERIFY ALL DATA CONTAINED HEREIN.THE DIMENSIONAL DATA CONCRETE IS PLACED,AND SUBMIT TO SOUTHOLD BUILDING 6. USE SCARF JOINTS AND APPLY CELLULAR PVC CEMENT TO ONE CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION DEPARTMENT WHERE REQUIRED. SURFACE. FASTEN AT BOTH SIDES OF JOINT. USE CEMENT w/CURE ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION TIME LESS THAN 2 HRS. EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A 16. PRIOR TO COMMENCING OPERATIONS ON SITE THE DRAWN BY:J.LACHAPELLE RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT 7. SAND RIPPED EDGES TO CLOSE OPEN CELLS(DISCOURAGES WATER CHECKED BY*J.LACHAPELLE THOSE SHOWN.CONTRACTOR SHALL NOTIFY ARCHITECT OF 'ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS ABSORPTION AND RESULTANT ORGANIC GROWTH). NOTE:THIS IS AN11"x17°SHEET DISCREPANCIES AS THEY ARISE. ADDITIONALLY INSURED: DRAWINGS MAYBE PRINTED NOT TO SCALE - LACHAPELLE ARCHITECTURE PLLC 8. CLEAN PVC TRIM ACCORDING TO MANUFACTURER INSTRUCTIONS 5. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY -CONTRACTOR TO CONTACT OWNER FOR OTHER PRIOR TO PAINTING. PRIME AS NECESSARY. LaChapelle Architecture PLLC FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK ADDITIONALLY INSURED NAMES SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY P.O.Box 1251 9. USE PAINTS(WHERE REQUIRED)w/LIGHT REFLECTANCE VALUE Mattituck,NY 11952 DRAWINGS. KIND UNTIL THE ABOVE IS PROVIDED. (LRV)OVER 55. USE SPECIALLY-FORMULATED VINYL-SAFE PAINT w/ (646)251-5058 jatuck,Nhap 1952chitecture.com SOLAR REFLECTIVE PIGMENTS. 6. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. 10. REPAIRS CAN BE MADE w/DAP'CRACK SHOT'FOR PAINTED TRIM. 7. THE STRUCTURAL MODIFICATIONS TO THE HOUSE INCLUDED REPAIRS ARE NOT ALLOWED ON UNPAINTED TRIM. REp ,4R HEREIN MAKE THIS A LEVEL 2 ALTERATION UNDER EXISTING C 5 LACHAp hi BUILDING CODE (EBC)CHAPTER 6. REQUIREMENTS OF BC CHAPTER 7 AND 8 APPLY AS A RESULT.CONTRACTOR SHALL 44, <<�, CAREFULLY OBSERVE THE REQUIREMENTS OF SECTION 806. 8. STRUCTURAL OBSERVATION IS NOT REQUIRED UNDER BC 1704.6 BECAUSE THE BUILDING IS NOT IN THE INDICATED RISK 9T��• 03393 CATEGORIES AND NOT A HIGH-RISE BUILDING. OF N9 9. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD TIIBDRAYAN05AN INSTF M 0%'0 SENV CEANDNEMA N9 BEPROPER m A<NAiELLE CHIfECTN3E FLLC PEONtDIFSB 0f WHEIHEfliME Pfl01Em foR WlOCN B IB FREPAREO E: ElQ W TED,NO CHANC ES.AITEPgTONS,OR DEIFIIONS MAY BE MADE IXCFR BY IACNAPELLE INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW aNSHTEcruaE c ws DRAx NC Awrnor BE usEO BrmNU PARREBEORD NEnrflorems. FOR ADDDN)N f0TN6 ME m BYm1ENFARIIEB.WIPoRCONPLLTIDNOFr EPRmECr BY o_PARIl6,MTHOm TIE WImfENCWKENi Oi IAGiARIIEARCIIRECfVAEPLIL 450.THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR mD�RBDHr=D=.�D„A�LLE^R�mED�EP t THIS OCCUPANCY R-3. 10. INTERCONNECTED SMOKE DETECTOR ALARMS SHALL BE NOTES PROVIDED IN CONFORMANCE WITH 'FIRE CODE'1103.8 AND CARBON MONOXIDE DETECTION EQUIPMENT MUST BE PROVIDED IN CONFORMANCE WITH 'EXISTING BUILDING CODE' SHEET NO: SECTION 804, IF NOT ALREADY PRESENT IN THE BUILDING. A2,00 SHEET 2 OF 12 ENERGY CODE NOTES WINDOW NOTES DOOR NOTES GEROSA/SULIS 1. THE WORK PROPOSED HERE MUST CONFORM TO ECCNYS R503 1. EXISTING WINDOWS ARE NOT'GANGED' FOR THE MOST PART, 1. SUBMIT A LIST OF ROUGH OPENINGS AND PROPOSED NEW DOOR RESIDENCE REQUIREMENTS FOR ALTERATIONS. BUT ARE INDIVIDUAL UNITS INSTALLED INDEPENDENTLY WITH SIZES PRIOR TO PURCHASE FOR OWNER/ARCHITECT REVIEW. 605 CIRCLE DRIVE 2x POSTS BETWEEN THEM. REMOVE EXISTING WINDOWS TO INCLUDE ACCESSORIES FOR OWNER CONFIRMATION. EAST MARION,NY 11939 2. IN ACCORDANCE WITH R503.112 EXISTING CEILING,WALL,OR EXPOSE FRAMING AND SUBMIT A LIST OF R.O.'S AND PROPOSED FLOOR CAVITIES EXPOSED DURING CONSTRUCTION OF AN WINDOW SIZES PRIOR TO PURCHASE FOR OWNER/ARCHITECT 2. SCRAPE, PRIME,AND PAINT ALL EXISTING INTERIOR DOORS THAT ALTERATION NEED NOT MEET THE REQUIREMENTS OF THE REVIEW.INCLUDE ACCESSORIES FOR OWNER CONFIRMATION. HAVE BEEN NOTED BELOW TO BE RETAINED. ECCNYS, PROVIDED THAT THE EXPOSED CAVITIES ARE FILLED w/ ® o INSULATION. 2. PROVIDE ANDERSEN TRU-SCENE WINDOW SCREENS 3. PROVIDE HARDWARE AT ALL NEW DOORS, PROVIDE NEW TRUE o 3. AS REQUIRED BY ECCNYS R503.1.4 NEW LIGHTING SYSTEMS MUST THROUGHOUT. LOCKSETS AT RETAINED EXISTING INTERIOR DOORS. NORTH CONFORM TO SECTION R404.1:ALL NEW FIXTURES WILL CONTAIN 3. PROVIDE NEW PVC TRIM AT ALL WINDOW EXTERIORS AND NEW 4. AT ALL EXISTING AND NEW DOORS PROVIDE NEW WOOD TRIM AT ® HIGH-EFFICIENCY LAMPS. WOOD TRIM, SILL,APRON AT INTERIORS; SEE DET.1/Al2. ALL INTERIORS; SEE DET.1/Al2. PROVIDE PVC TRIM AT EXTERIOR. PROJECT WINDOW & DOOR SCHEDULE, ENERGY CODE COMPLIANCE `33Ra4�' Q U-FACTOR/R-VALUE SHGC TAX MAP SCTM#-1000.21.-3-7 ID ASSEMBLY MAKE/MODEL DIMENSIONS HARDWARE NOTES QTY ECCNYS PROPOSED ECCNYS PROPOSED # ISSUE/REVISION DATE A DOUBLE HUNG WINDOW ANDERSEN 400 TW2642 32"w x 52"h PER OWNER LOW-E4 9 0.32 0.30(PASS) 0.40 0.31 (PASS) .00 FILING SET 12.12.2023 B CASEMENT WINDOW ANDERSEN 400 CX145� 32"wx 52"h PER OWNER LOW-E4 5 0.32 0.30(PASS) 0.40 0.31 (PASS) C TRIPLE CASEMENT WINDOW ANDERSEN 400 CX245 70"w x 52"h PER OWNER LOW-E4 2 0.32 0.28(PASS) 0.40 0.32(PASS) D CASEMENT WINDOW ANDERSEN 400 C125 24"w x 28"h PER OWNER LOW-E4 2 0.32 0.30(PASS) 0.40 0.31 (PASS) DRAWN BY:J.LACHAPELLE 1 FRONT ENTRY DOOR REEB THERMA-TRU 36"x 80" PRIVACY, DEADBOLT LH, FIBERGLASS w/RH STORM DOOR 1 0.32 0.25(PASS) 0.40 0.17(PASS) CHECKED BY.J.LACHAPELLE 2 REAR ENTRY DOOR REEB THERMA-TRU 32"x 80" PRIVACY, DEADBOLT RH, FIBERGLASS w/STORM DOOR 1 0.32 0.25(PASS) 0.40 0.17(PASS) NOTE:THIS IS AN 11"x 17"SHEET 3 SLIDING PATIO DOOR ANDERSEN 72"x 80" PER OWNER LOW E4 TEMPERED 1 0.32 0.30(PASS) 0.40 0.28(PASS) DRAWINGS MAY BE PRINTED NOT TO SCALE 4 COAT CLOSET DOOR EXISTING 26"x 80" PASSAGE RH,SCRAPE&PAINT 1 LaChapelle Architecture PLLC 5 LAUNDRY CLOSET DOOR EXISTING 26"x 80" PASSAGE RH,SCRAPE&PAINT 1 P.O.Box 1251 Mattituck,NY 11952 6 MASTER BEDROOM DOOR REEB PR8782 30"x 80" PRIVACY RH,2-PANEL SHAKER,PTD. 1 (646)251-5058 jake@lachapeilearchitecture.com 7 LINEN CLOSET DOOR EXISTING 30"x 80" PASSAGE DBL DOOR,SCRAPE&PAINT 1 8 MASTER BATHROOM DOOR REEB PR8782 28"x 80" PRIVACY RH,2-PANEL SHAKER, PTD. 1 9 MASTER CLOSET DOOR EXISTING 60"x 80" PASSAGE LH,SCRAPE&PAINT 1 10 BEDROOM 2 CLOSET DOOR REEB PR8782 42"x 80" OVERHEAD TRACK DBL BIPASS,2-PANEL SHAKER, PTD. 1 �5���ACI 11 BEDROOM 2 DOOR REEB PR8782 28"x 80" PRIVACY RH,2-PANEL SHAKER, PTD. 1 a 12 BEDROOM 3 DOOR REEB PR8782 28"x 80" PRIVACY LH,2-PANEL SHAKER, PTD. 1 13 BATHROOM 2 DOOR REEB PR8782 28"x 80" PRIVACY LH,2-PANEL SHAKER, PTD. PLEASE PROVIDE DEDUCT ALTERNATE FOR ANDERSEN 200 SERIES INSTEAD OF 400 SERIES WINDOWS �T Q 03393 LIGHT FIXTURE SCHEDULE • MUST MEET R310 EMERGENCY EGRESS OPENING REQUIREMENTS N Ew ID FIXTURE TYPE MAKE/MODEL TEMPERATURE WET LOCATION FULL CUTOFF NOTES TMS DltAWINGIBPN INSTHGMEM OFSESMCEANDREMNN9 TNF PROPEFBYOF LPCMAPELLE AA PPCHIfECNPE PLLC PEOGROLESSOFNMEMEPTNEPROIECf fOR WNICHIT IS PREPPAED IS E%ENTED.NO CNMIGEB,pLTEAATIONSORDFLLlIONG MAYBfi MnDE E%CEPf BYLACHPPELLF EXTERIOR SCONCE LNC HA03156 MAX.3,000K YES YES LANTERN SCONCE,WEATHER/CORROSION RESISTANT,PROVIDE LED BULBS ARCXNECTUREP LTNSONAM NG MAYNOTBE BBEOB OMEA PAR ES FORD HER PROIEC 4, iOPPOD1IlON TO MIS PPOIECTGYOT16A PGRRES,ORFOP COMP(kTION OGTMB PPOIECT BY OMEP PPRDES,YJIFXOOi ME W W"Ex CONSENTOi IACNAPELLEgfiClpR4TLPtE P4C. ®COPDLGNT F0F0IOLW8EL3EYPLNRFCTUP'e PLLC BB INTERIOR SCONCE KICHLER 624-NI 2,700K YES N/A BRUSHED NICKEL,ENSURE J-BOX IS HIDDEN BY FIXTURE, PROVIDE LED BULBS CC INTERIOR SCONCE KICHLER 628-NI 2,700K YES N/A BRUSHED NICKEL,ENSURE J-BOX IS HIDDEN BY FIXTURE,PROVIDE LED BULBS ENERGY CODE DD INTERIOR RECESSED WAC R3ARDT-N827-WT 2,700K NO N/A WHITE FINISH COMPLIANCE EE INTERIOR COMB.VENT FAN PANASONIC 1115VKL2 3,000K YES NIA WHITE FINISH,COMBINATION BATHROOM VENT FAN-MIN. 100 CFM,MAX. 1.5 SONES SHEET NO: FF LINEAR UNDER-CABINET WAC PRO 2 MAX.3,000K NO N/A TAPE LIGHT, MOUNT DRIVER ON TOP OF CABINETS GG CEILING FAN w/LIGHT SELECTION BY OWNER 2,700K NO N/A PROVIDE HANGER,WALL CONTROLLER,PROGRAM REMOTE A3mOO PLEASE PROVIDE DEDUCT ALTERNATE AT(3)BEDROOMS:ACCESS LIGHT[NG'CONGA'5008OLEDDLP-BS/OPL INSTEAD OF CEILING FAN SHEET 3 OF 12 � 0 � � G EROS�►/SU LIS E le RESIDENCE 515 CIRCLE DRIVE U 605 CIRCLE DRIVE J A N 2 6 2024 EAST MARION,NY 11939 .000 / €, P S / �s baC:t��-iifia@Ce o 0-00 TRUE TRIM TREE CANOPY - ,� OVER PARKING AREA ` 615 CIRCLE DRIVE / NORTH o ° o q F o (2) PARKING SPOTS NEW 324 SF PAVER PROJECT PATIO AT GRADE ` ` / (33.84° ') 4 b q 0000 40-0 0-00 _... '. REPAIR EXIST. 16 SF /` TAX MAP SCTM#-1000-2L3-7 <o?�G -- FRONT STEP o" 14' E # ISSUE/REVISION DATE ,,, ,, T .,.., •T_ ' b .00 FILING SET 01.26.2024 ` 4"CRUSHED-BEACH - PEBBLE PARKING �i ' //,// ` DRAWN BY:J.LACHAPELLE w/R.R.TIE `..'. ., .. CHECKED BY:J.LACHAPELLE y/605 CIRCLE DRIVE e j//� APPROX. L/OC. OF EXIST. NOTE:THIS IS ANil"x17^SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE SANITARY SYSTEM RESET AND SQUARE STAIR: %�/ � /" �/��� LaChapelle Architecture PLLC 7T@10 ME% REMOVE COOKING GAS P.O.Box 1251 REPAIR RAILING AS /�°' 0 0 NECESSARY � Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com NEW PAVER WALKWAY; 3'x3' REAR ENTRY 36"WIDE STAIR / EXIST. ONE-STORY NEW BLUESTONE WALK E D ARC RESIDENCE TO OUTDOOR SHOWER ��\P �ACHgAFyi� NEW 4"CONCRETE PAD <<�n REINFORCED w/WWM FOR -) ` NEW ELECTRIC HEAT PUMP ` O Un , 03393 y0�� OF N APPROX. LOC. OF E`N EXIST.WELL-HEAD STHIGDMwIN0 INGDiOmENr0F6=CE DREMNMTHEPROPEREr0 Vtl4V aRCNREmUR6 PLLCflEG/IROLESSOfYMEiNERTNE PIImERF0NWr11CHRI5 PREPAFE015 NOCMNVGEe.ALTFRgnON6,OROELEnpN- DEmaDEE%C— UKNA E 670 CEDAR DRIVE usN rtmunE Puc.rNsoraw NG may NoreE usEo erm¢R PaRn sFoao NnMNECS FOR aoonux TD TNI6 PRa Fcr Dr orx ER PaRnEs,oR F oR comPtFrloN m rms PRaiEm 6r mNEPPARnE5,N11HODf 1XENIORENCON6II"m LAQIARllE NiCWIFCTL9lE PLLC m COPttCGM 2D]I IACNaPELE pRCImECN R6 PLLC SITE PLAN 00001, ` / PROJECT TRUE SHEET NO: OSITE FLAN NOT A MEASURED SURVEY-DATA DERIVED FROM AERIAL IMAGES SEPT.30, 1977 CERTIFICATE OF OCCUP69CY WAS ISSUED FOR NORTH NORTH A4mOO SCALE: TV 20' AND PREVIOUS SURVEYS FOR ADJACENT PROPERTIES THIS"PRIVATE ONE FAMILY DWELLINCv WITH ADDITION". (14.34') SHEET 4 OF 12 -SCOPE NOTES: DEMOLISH AND PROPERLY REPLACE EXIST.2x4 G EROSA/SU LIS 1.FURNACE TO BE REPLACED BY OTHERS w/ELEC.HEAT PUMP DISPOSE OF FUEL OIL TANK, BRACES AND FOOTING 2.PROVIDE MOLD REMEDIATION BY QUALIFIED CONTRACTOR PUMPS,AND PIPING w/NEW 2x4 FRAMING RESIDENCE PRIOR TO START OF ANY BASEMENT WORK @16"O.C.;NEW SILL 3.PROVIDE VALVES/MANIFOLD IN BASEMENT AND GRADE TO NEW S.S.PIPE RAILING AT PLATE AND TOP PLATE; 605 CIRCLE DRIVE ALLOW OWNER TO DRAIN AND BLOW OUT WATER SUPPLY BASEMENT STAIR TO EAST MARION,NY 11939 NEW CONT.FOOTING SYSTEM IN HOUSE FOR WINTERIZATION UNDERSIDE OF HATCH EXIST.B SEMENT SIM.TO DET.2/Al2 4.COORDINATE WITH ARCHITECT TO SELECT AND APPLY NEW INTERCONNECTED CARBON STAIR: 'DRY-LOCK'COATING AT BASEMENT MASONRY WALLS �,� DEMO EXIST.8"CMU MONOXIDE DETECTOR 5.PROVIDE 10-MIL CLASS A PLASTIC SHEETING VAPOR BARRIER 9 R @ 82 COLUMN ON CONCRETE SUCH AS STEGO-WRAP FOR ALL CRAWL SPACES;SEAL AT ALL (2)NEW CEILING PORCELAIN 8 T @ 814" FOOTING AFTER NEW TRUE p O oa q� BASE FIXTURES,OR PER NORTH PENETRATIONS AND PERIMETER FOOTINGS PLACED OWNER p o a o — — — —— — — — — — — — — — — — — — — — — ® o " PROJECT O EXIST.8 CMU RETAINING �,,._ _® $ UP NORTH S] WALL,APPROX.4'-10"TALL I TAX MAP SCTM#-1000-21.-3.7 NEW GFCI OUTLETS @ 48 AFF I I V I I I # ISSUE/REVISION DATE CRAWLSPACE NEW 200A ELECTRIC I I BREAKER PANEL I I I I I .00 FILING SET 12.12.2023 EXIST.FUEL OIL FURNACE REMOVAL&REPLACEMENT SEMENT GFCI L------- -- BY OTHERS;PROVIDE POWER FOR MITSUBISHI GFCI M-SERIES#SVZ-KP36NA DUCTED FAN COIL UNIT _ OXX EXIST.8"CMU WALL ON 12" APPROX. V-7" � I DRAWN BY:J.LACHAPELLE � DEEP CONCRETE FOOTING EXIST. CRAWLSPACE I CHECKED BY:J.LACHAPELLE 5'-0" 5'-0" <5'_p" ! STEEL LALLY 4'-3" 41-3" I DRAWINGS NOTE:THIS IMAY EPRNTEDNOTTOSCALE I -- -- -- -- -- COLUMN -- - I ir - ...:. - -J ---- ' -----; i— ;_----; L___ LaChapelle Architecture PLLC W BASEMENT FLOOR i P.O.Box 1251 REPLACE EXIST. EXIST.(2)2x6 GIRDER i O EL.-7'-10" Mattituck,NY 11952 FOOTINGS WITH REPLACE EXIST. (646)251-5058 jake@lachapellearchitecture.com NEW TYP. i i o FOOTING WITH i NEW TYP. EXIST.BRICK CHIMNEY BASE i GFCI EXIST.HWH,NEW GFCI GFCI -------------------------------------------- REMOVEI �FZED ARC RHEEM 65 GAL. HYBRID HEAT AS-H y EXIST.2x6 JOISTS PUMP HOT WATER HEATER; I I I �F� AAFI " @ 16"OVERHEAD CONDENSATE PUMP TO i i APPROX.11'-2" Of I DRAIN;VENT TO ROOM; i i I I EXIST.2x6 JOISTS @ 16"OVERHEAD . PROVIDE LEAK DETECTION i rn k � � I --------� I /1/'C). 0339D y0� I --- OF NE`N IL - - - - - - - - - - - - - - - - - - - - =- - - = - - =- - - - - - - - - - - - - - - - - - - - - - - - - - - - J REPLACE EXIST. EXISTING AREA OF NEW DEHUMIDIFIER;PROVIDE REPLACE EXIST.2x4 BRACES AND REPLACE EXIST. TMSD"WU"ERi°iFFRFRDRFRD"EDP YDi�"PFUE VENTILATION LOUVER AT DROPPED FRAMING AT DEDICATED OUTLET AND FOOTING w/NEW 2x4 FRAMING VENTILATION LOUVER AT � �°RFDARDFUDi�RE"ERT�P�'E°`DRFR F PPD� E%ECUIED.NOOHARGF5,0.LTFRATIOHS,OROELEIIOHSMAYBE MAOFE%CEPf BYIACHLPFLE AROXDFDTURF PLLC iH15 DRAWING MAY NOi BE USED DY OTHER PARf65 i0R OM FA PROIFCrs, CRAWLSPACE WALL w/ BATHROOM ABOVE CONDENSATE PUMP TO /�16"O.C.•NEW SILL PLATE AND CRAWLSPACE WALL w/PTD. //]) ' OMFRPA"fiFS.QCOPYPoGMtWO I'MIALXAPELLEARCWiECiUIIE�"FRUIg PLLC PTD.ALUMINUM LOUVER EXTERIOR OR DRAIN TOP PLATE;NEW CONT.FOOTING ALUMINUM LOUVER PROVIDE POWER FOR SIM.TO DET.2/Al2 BASEMENT PLAN MITSUBISHI M-SERIES #SUZ-KA36NAHZ OUTDOOR HEAT PUMP TRUE PROJECT SHEET NO: 0 NORTH NORTH OBASEMENT PLAN EXISTING (14.34') SCALE: 1/4" = T-0" PARTITION A5,00 SHEET 5 OF 12 SCOPE NOTES: 1.REMOVE EXISTING ELECTRICAL;SEE AB FOR NEW LAYOUTS �� r` DEMOLISH BILCO REFRAME AT NEW GEROSA/BULIS CELLAR HATCH; DOOR AND WINDOWS RESIDENCE (� V PROTECT CONCRETE RELOCATE WALL EgST MARIO DRIVE IVE 605 CIRCLE DR�\ REMOVE FIRST STEP; WALLS AND STAIR REGISTER AND DUCT PROTECT LANDING& / PER A711939 KNEE WALLS i DEMOLISH ALL FINISHES EXIST.STAIR: /� �� AT KITCHEN INCLUDING REMOVE ALL CARPET; DEMOLISH ALL DEMOLISH ALL PROTECT EXISTING EXISTING WINDOWS EXISTING INTERIOR DN 2R @ 7Z' / CABINETS,TRIM,GWB, WOOD FLOORS VINYL FLOORING AND EXTERIOR DOORS 1T 12 �� /�' TRUE o v q 1 N 47'-4" NORTH 0 a 2 a}�32 x 49.5 D.H — — — — — — — MODIFY FRAMING — --6L'x3511_aH L2 II _D_K— — — — 39"x 49.5lDJi — — — o 9 C3 a o FOR 36"DOOR PROJECT 0 O H \,xx xxxxxx x x x x x x x x x x x NORTH 9 x x x x x x x x x x x x x x x x x (33.sa°)x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x TAX MAP SCTMS-1000.21.37 fz x x x x x x x x x x x x x x x x x� -x x x x x x x x x x x x x x x x x x x�I # ISSUE/REVISION DATE x x x x x x x x x x x x x x x x x x x x KITCHEN ) �I _ x x x x x x x x x x x x x x x x x x x x �� �� x x x x x x x x x x x x x x x x x x x W .00 FILING SET 12.12.2023 o I 14-$ 'z 9-1 I C) I N x x x x x x x x x x x x x I �-- x x x x x x x BEDROOM2xxxxxxx x I co A x LIVING ROOM i xxxxxxx9lxx9,xln xxxxxxx r xxxxxxx 'xYlx xx.7xxxxxxxxx Cl) 18'-8"x 9'-11" I x x x x x x x x x x x x x x x x x x x x 11 o aI REFR. i �x x x {SREL©CATE WALL x " x I DRAWN BY.J.LACHAPELLE —_� Vi1T xx kZ�GjSt' x — YY�11 R,ANO O PROTECT EXIST. i ^ x x x x x x x PER A7 x x x x x x x z I CHECKED BY:J.LACHAPELLE _ _ _ _ _ _'_ �" x x x x x x x x x x x x x x x x x x x x I NOTE:THIS IS AN 11"x 17"SHEET WOOD FLOORS — — — — — — — ro DRAWINGS MAY BE PRINTED NOT TO SCALE THROUGHOUT DEMOLISH I DOORFRAME GROUND FLOOR BATHROOM 2 0I x AND HEADER DEMOLISH HEADER I1,3 Co _ LaChapelle Architecture PLLC AT KITCHEN ONLY I - I � P.O.Box 1251 _ ONCE BEDROOM _ Mattituck,NY 11952 LL1S BUJT'TADfD ----------- ----'--- I (646)251-5058 jake@lachapellearchitecture.com CEILING JOIST LOADS TRANSFERRED xxxxxxxxxxxxxxxxxxxxx I w = x x x x x x x x x x x x x x x x x x x x I N= oDINING ROOM xxxxxxxxxxxxxxxxxxxx I � D qRC' I13'-11"x12'-7" x xxxxxxxxxxxxxxxxxxx I MASTERBEDROOM 1 o x xxxxxxxxxxxxxxxxxxx XI I IE I PROTECT EXIST. x x x x x x x x x x x x x x x x x x x x x I v P l 12-11 x9-3 xxxxxxx xxxxxxx = ��+ � N Cl) WOOD FLOORS x x x x x x x B( 'EDRYOOM}�3 x x x x x x x ' x x x x x x x `k— St x x x x x PROTECT EXIST. THROUGHOUT - ' x x I WOOD FLOORS xxxxxxxxxxxxxxxxxxxxx s THROUGHOUT i Ho o '� xxxxxxxxxxxxxxxxxxxxx x x x x x x x x x x x x x x x x x x x ��c 0339 �xx x x x x x x I I L _ - - - - - -(!2)-@-32LLx49.5°-".- - - - - - - 24 26`D.H-- - - - -(3)-@-26'x-46"O.H- - - - �- - - - - - -s2' 4 5�.+r - - - - TNiE DRAN1N019fJ1INRRCMENi CFM EPNDREMAIN MPROPERIrof LACXPPELLE MODIFY FRAMING FOR DEMOLISH BATHROOM BATHROOM 1 SAW CUT WOOD FLOORING IRCHI EC UNEP CPEMRC FSSOf KMEMER HE PRC ER CP NM CN RIEPPEPAPEC S DEMOLISH REMOVE ALL Exarto.nou wcExurtPanaN;oR o¢Enoxs mnreEumEFxcEr Bx ACWJELE LARGER WINDOW FIXTURES&FINISHES, AS NECESSARY TO °WA—MM^� Y N�T����TM�P�RPE=foP�NEwPRo V oomoNro nnv mmEerarmrenPamEs,ow faP anPLEnon atxls PPoIEn er REARSTAIR CARPET; PROTECT ONEn P?R ES.Y�TNIXRnE2023 NCONS A AG CWREARCNREC CRERL PROTECT mG GROUND CNREPLLC LINE OF EAVE INCLUDING TILE AND GWB INSTALL BOTTOM PLATES AND LANDING EXISTING WOOD OVERHEAD FOR NEW PARTITIONS FLOORS EXIST. DN FLOOR PLAN- OUTDOOR DEMOLITION SHOWER s TRUE PROJECT SHEET No: GROUND FLOOR PLAN - DEMOLITION 0 �Illllll� NORTH NORTH EXISTING DEMOLISH WALL REGISTER (14.34°) 1 SCALE: 1/4" = T-0" PARTITION PARTITION OR A6mOO ADJUST FRAMING SHEET 6 OF 12 ►-7�I-I�I�I�I7�I�I7-ICI-I-��I�I�I` ►�j�j�j�j�j�j�j�j�j�j�j�j�j�j�j�j�j� ►�j�j���j�j�jj go ge j�j�j�j� •- • y�I�I�I�����I�I�I�I���I�I�7�7�I�TI�I�I�I�I����►I�I�7���I�I���I���I���I���I�I�I�I���I��I1I�I�I���I�I�I�I��� • , • ULIS ••• ••- -• ► �j� �j���j�j��� • a •.- -.. - . .•-�L�i`a���i� i�i�i�i�i % ��������������������������� �� ����� ������� ����`���`�`��i� �i�i�i� � i�i�i�i�i�i� RESIDENCE mom ••- . � - .•- i�i�i�i �i�i�i�i�i�i�i:'vim ' ' • �i�i�i�i�i�i�i�i�i�i"- • i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i� �������������ti�����%���� �������������������������������i 605 CIRCLE DRIVE �i�i�i�iJi�ii�►�i�i� . - . . - -• r�i�i�i�i�i,.i� ►►,��j�j� j�j�j� ------------ mill JIM ►sssss., . •- • • ; ►.•.•.•.•.•.•.s.•.• .•,►.•.•, :.• . • •- '• • . • • • DIMENSIONS SLIDE . •- � �� � �, I►� i�i� i�i�i i i ♦ ♦i i i i i i i i�i�i�i�i��i�i�i�i�i i i i i i i ♦i�i����� " -. �� ►i�i�i�i�i�i�i ��, :i�i�i�i���i�i�i�i�i�i�;i�i�i� rI o �� �lcic • �I�I�I�I� �I�I �I�I�I�I�I�I .n r—t�I�I.�I�I� _ • il `�i'������1�I►�� �i i�i�►�i���ili�i. .�-i�i�►i�i��i�i.11�1� 1���� � �� ADDITIONAL-, • MOUNTMODIFY IA -WOOD FRAMING FOR PROVIDE APPROX.30"x9O"PAINTED 3/4" BIRCH PLY PANEL, :• /�. I •= O ABOVE TOP-LOADING WASHER;#38481 BY m___ _ 1 �® • BRUSHED-NEW HAT SHELF AND 1.31 m 1 O i mow• DUTY HANGER ROD jJ1 LIVING ROOM Em DRAWN BY,J.LACHAPELLE • —lll:l Mpl I I Iwo I m ri 1-1,1111siolo I Il 11 10 LaChapelleP.O.Box 1251 1.31"BRUSHED MINERAL WOOL NICKEL HEAVY DUTY HANGER ROD BEDROOM 2 WALLS �� �i� C • . top ADDITIONAL 03393 -WINDOW - \I_I�L�■�_/ •- FLO PLAN- OR • �••- CONSTRUCTION SHEET NO: ..• O '• 102 a tolol' 'WAJATOO • •- • •- SHEET 7 OF 12 SCOPE NOTES NOTE:COORDINATE LAYOUT OF CEILING FANS AND RECESSED LIGHTING GEROSA/RU LIS 1.PROVIDE NEW LIGHT FIXTURES AND SWITCHING THROUGHOUT TO AVOID INTERFERENCE;REVIEW WITH ARCHITECT AND OWNER 2. PROVIDE NEW CONVENIENCE OUTLETS THROUGHOUT AS INDICATED;RETAIN RESIDENCE CODE-COMPLIANT WIRING AND REPLACE NON-COMPLIANT WIRING;EXISTING 605 CIRCLE DRIVE OUTLET LOCATIONS ARE SHOWN,NEW LOCATIONS INDICATED w/'ADD' PROVIDE TIMER/INTERNET PATCH CEILING AT AREAS OF PROVIDE DUCT FROM REMOVE AND PATCH EAST MARION,NY 11939 3.PROVIDE NEW SWITCHED(HALF-HOT)OUTLETS IN BEDROOMS AS INDICATED ADDRESSABLE CONTROL DEMOLITION,HEADER REMOVAL, OVER-THE-RANGE ATTIC HATCH 4.PROVIDE(2)NEW GFI OUTLET CIRCUITS IN KITCHEN, PLUS NEW APPLIANCE FOR EXTERIOR LIGHTS AND NEW PARTITIONS MICROWAVE TO ROOF DUCT BATHROOM OUTLET CIRCUITS AS NEEDED PROVIDE(2)2x6 HEADER PROVIDE ACCESS PROVIDE 2 NEW 2xl0 VENT FAN TO EXIST. 5.REPAIR GWB CEILING AT ALL REMOVALS,NEW PARTITIONS,AND EXISTING ( ) AT REFRAMED DOOR IN WALL FOR LOW HEADERS AT NEW VENT AT EXTERIOR o BLEMISHES;SKIM TO LEVEL 5 FINISH VOLTAGE HVAC CASEMENT WINDOWS AN WALL TRUE ® 0 0 oa q CONTROL WIRES SLIDER;2 JACK STUDS NORTH O AA O oa GFCI 0 0 - $D$D$i / $E$D$$$/--- NRTH PROJECT � ® q D D \ DRNER LOCATION FOR UNDER I j/I RELOCATE (33.84 CABINET LIGHTS TO BE CHOSEN GFCI Wm BY ELECTRICIAN AND OWNER ��/ I i -- TAX MAP SCTM#-1000-21.3-7 QJ \ , ADD �QD 0QD ', ADD REF ODD .ADD I'/I i'I DD\}\ `\ ODD AD QUAD GFCI # ISSUE/REVISION DATE ,1 '--------'' ------ ; --------------- ' LIW./FP.' AT END `` ; I/ BELOW i ` ' /' ` .00 FILING SET 01.26.2024 i . FF �\`J/� COUNTER � i f ADD OD ® GFCI /II GG GG % RANGE ij j� FF __ __ � GFCI II DRAWN BY:1.LACHAPELLE FF MIC. FF /ADD,& CHECKED BY:J.LACHAPELLE ,_--------- ----- t% '� —% — — •/ /GFCI �VE 44 UN 0 TER //'- NOTE:THIS IS AN 11"x SHEET ` O .\ ; ` I� •'� ,, // j / ,/ / DRAWINGS MAYBE PRINTED NOT TO SCALE RELOCATE ODD DD ;DO ADD ' LaChapelle Architecture PLLC $$ - - D P.O.Box 1251O - `` -2 / a ti uc /D��// (545) 51 5058 jake@lachapellearchitecture.com Iacha eIIearch itectureco m/i ADD/// / ✓ AD CI CC/ F'O DD - ADD \-------- -- j / ADD "l , DO / DD ADD ADD RELOCATE'GG U �ERED AR sc / -{ / EE /BB ®� I/ 1' �O /// ADD"GFCI O GG DO DD / / RELOCATE / ADD RELOCATE t�O , I F 0339 �( �Q NEW , FVI TWSDMNirvD pAN INSIPDMFM OFBFRr10EAN0 pEMAINBTRE PRWEPYY Df LACXAPELLE pRCNIIECNRE PLLC REGARDLESS OF WHETNERTNE PPOIEmf01]WNICN"IB PpEPA4ED R FALBf ED.XO CNANG FS.ALTERATIIXIS,Dp DELEYICN9 MAY BE MADE IXCEPE BY IMHAPEl1E COPE NOTES(CONY.) NEW FOLD-DOWN ATTIC LADDER, ARCHYEC]UREPLLC ISMWEW"MAY NOTBE DSEDBYC HERVA 0N0FRDYRERPpffV fDRADDrtIory io iRis PRaEmermwRVARYIES,aR fopwMPLEnorvaf rRls PPorzn Br 6. PROVIDE NEW 2x6 CROSS FRAMING(STABILIZE w/BLOCKING)PERP. DUCT BATHROOM FAN WARNER OR SIM.; PROVIDE ZIPPERED ° Pia"" ""TME NF EM CO SER C4 ACHAPEUEAR REmDRE PLLC � DUPLEX ELECTRICAL RECEPTACLE mCOPYfBCNE]D]CUYINPEl1EYK1A}ECNPEPl1C TO EXISTING JOISTS IN AREAS ADJACENT TO NEW ATTIC HATCH AND TO ROOF INSULATED ATTIC STAIR COVER FASTEN 1/2"PLYWOOD TO NEW FRAMING TO PROVIDE APPROX.250 REPLACE CEILING IN QUAD ELECTRICAL RECEPTACLE GROUND SF OF STORAGE BATHROOM 1 SC SMOKE+CARBON MONOXIDE DETECTOR;INTERCONNECTED FLOOR RCP & 7.PROVIDE SWITCH AT TOP OF ATTIC HATCH LADDER AND(4)ATTIC ELECTRIC PLAN LIGHTS SPACED DOWN THE LENGTH OF THE RIDGE BEAM; PROVIDE ❑T NEW THERMOSTAT OUTLET AT TOP OF HATCH TRUE PROJECT $ NEW SWITCH SHEET NO: $ NEW SWITCH w/DIMMING-COORDINATE TO FIXTURE NORTH NORTH OGROUND FLOOR REFLECTED CEILING PLAN $ NEW 3-WAY SWITCH (14.34') A8,00 SCALE: 1/4" = T-0" $, NEW SWITCH w/VENT FAN TIMER SHEET 8 OF 12 REMOVE WINDOW BOXES AND SHUTTERS AT ROOF HOOD FOR PROVIDE 5/4"PVC TRIM AT EXTERIOR TO MATCH EXISTING, REPLACE ROOF, G EROSA/BU L,IS NORTH ELEVATION WINDOWS;REPAIR OR KITCHEN EXHAUST RETAIN EXIST.J-BEAD AND EXISTING SIDING-MODIFY SIDING GUTTERS, LEADERS REPLACE SIDING AT REMOVED FASTENERS ONLY AS NECESSARY AT WINDOW REPLACEMENTS; TYP. RESIDENCE 605 CIRCLE DRIVE EAST MARION,NY 11939 TRUE NORTH O D ® o PROJECT NOTH (33R ") 0 0 q TAX MAP SCTM#-1000-21.-3-7 # ISSUE/REVISION DATE I--J I---�r— --� \ --------- L- -J ---- --------- \ r- ---------- .00 FILING SET 12.12.2023 i PATCH AT REMOVAL OF PROTECT EXIST.HOSE BIBB DRAWN BY:J.LACHAPELLE ONORTH ELEVATION FUEL OIL TANK FILL PROTECT EXIST.DRYER REMOVE AND REATTACH SHUTTERS AT THIS CHECKED BY.J.LACHAPELLE 1 SCALE: 1 4 = 1 -0 VENT HOOD WINDOW;REPAIR OR REPLACE SIDING AT NOTE:THIS IS AN 11"x 17"SHEET REMOVED FASTENERS DRAWINGS MAY BE PRINTED NOT TO SCALE LaChapelle Architecture PLLC ROOF REPLACEMENT NOTES PROVIDE 5/4"PVC TRIM AT EXTERIOR TO MATCH P.O.Box 1251 1.SUBMIT PRODCUT DATA FOR PROPOSED ROOFING EXISTING, RETAIN EXIST.J-BEAD AND EXISTING Mattituck,NY 11952 SYSTEM TO ARCHITECT AND OWNER AND OBTAIN SIDING-MODIFY SIDING ONLY AS NECESSARY AT (646)251-5058 jake@lachapellearchitecture.com ACCEPTANCE PRIOR TO DEMOLITION OF ROOF WINDOW REPLACEMENTS; TYP. 2.RIP EXISTING ASPHALT SHINGLE ROOF AND REFRAME FOR ADDITIONAL WINDOW; UNDERLAYMENT FELT RELOCATE JACK AND KING STUDS NEW(2)2x8 3. PATCH EXISTING SUBROOFING AS NECESSARY 12 RE A R HEADER,NEW SILL AND ADDITIONAL CRIPPLES AC H t y 4.PROVIDE ICE&WATER CONTINUOUS AT EAVES 5 � \`� �L qp 5.PROVIDE(2)LAYERS OVERLAID 30# OR SYNTHETIC NEW FULL-HEIGHT 4x4 POST BETWEEN ROOFING FELT, IN CONFORMANCE WITH R905 WINDOWS 6. PROVIDE ASPHALT SHINGLES PER OWNER SAMPLE IF 7. PROVIDE COPPER OR OTHER ACCEPTABLE METAL STEP AND COUNTER FLASHING LET INTO BRICK CHIMNEY ,r 9T�Q 03393� OQ�, �0 NE`N � THIS ORALNNG ISAN INSIHUNEM OIGFIMCE IWDREMAINSIXEPROPERFY OF ICCNAVELLE AflCN1iEC1URE PNL REGAItOLEs;OF N1IETNFR THE PROIECI FOR VMICN R IS PREPARED B E%ECUIED.NOCNNiGEG,LLTERPTIIXI3,pRDFlMM NAY 6E1-IMCEPTDYWC ECT MPMIECIUPE PLLGTXt$OPANING NU1T lIOTGFOSED 6IOTIRA PARREG FOROINER PYN)IECT; fORADDIfiON iOTNlS Pp01ECT UYOTIfAPARRES,OR FOR COMPIFION OFTMGPROIECf 9Y aMEfl cc--- PARDES, -OUf INENRI"fN CONGENT01 WGNAPELLEARCMRECTURE PLLO. Ni]02$LACNAPFLLEARCWRCTUREPLLC NORTH & EAST ELEVATIONS EAST REPLACE ALUMINUM LOUVER SHEET NO: O SCALE 1/4ATIONC A9mOO SHEET 9 OF 12 REPLACE ROOF, PROVIDE 5/4"PVC TRIM AT EXTERIOR TO MATCH EXISTING, PROVIDE COPPER OR OTHER ACCEPTABLE ROOF HOODS FOR G EROSA/BU LIS GUTTERS, LEADERS RETAIN EXIST.J-BEAD AND EXISTING SIDING-MODIFY SIDING METAL STEP AND COUNTER FLASHING LE BATHROOM EXHAUST ONLY AS NECESSARY AT WINDOW REPLACEMENTS; TYP. INTO BRICK CHIMNEY RESIDENCE 605 CIRCLE DRIVE EAST MARION,NY 11939 TRUE O 08 q NORTH O _ O o .q o E3 Li n PROJECT NORTH V( 9 (33.84°) \ \ \ \ \ TAX MAP SCTM#-1000-21.-3-7 \ Lj \ \ \ # ISSUE/REVISION DATE \ .00 FILING SET 01.26.2024 — — REFRAME FOR MODIFIED WINDOW ARRANGEMENT; DRAWN BY:J.LACHAPELLE CEMENT PATCH AT BLOCKED NEW SHOWER VALVE AND RELOCATE JACK AND KING STUDS,NEW(2)2x8 CHECKED BY:J.LACHAPELLE OSOUTH ELEVATION OPENING IN FOUNDATION TO HANDLES AT OUTDOOR SHOWER HEADER, NEW 4x4 POST BETWEEN WINDOWS, NEW 1 SILL AND ADDITIONAL CRIPPLES NOTE:THIS IS AN 11"x 17^SHEET SCALE: 1/4" = T-0" ACHIEVE UNIFORM FINISH DRAWINGS MAY BE PRINTED NOT TO SCALE PROTECT EXIST. HOSE BIBB LaChapelle Architecture PLLC P.O.Box 1251 PROVIDE 5/4"PVC TRIM AT EXTERIOR TO MATCH Mattituck,NY 11952 EXISTING, RETAIN EXIST.J-BEAD AND EXISTING (646)251-5058 jake@iachapellearchitecture.com SIDING-MODIFY SIDING ONLY AS NECESSARY AT WINDOW REPLACEMENTS; TYP. 12 REFRAME FOR ADDITIONAL WINDOW; RE D 4.0 5 RELOCATE JACK AND KING STUDS,NEW(2)2x8 OAS v ACHq,oC'Si HEADER,NEW SILL AND ADDITIONAL CRIPPLES REMOVE AND REATTACH SHUTTERS AT WEST NEW FULL-HEIGHT 4x4 POST ELEVATION WINDOWS; REPAIR OR REPLACE SIDING AT REMOVED FASTENERS BETWEEN WINDOWS REMOVE WINDOW BOXES; REPAIR OR REPLACE 0 �T 0. 03397D O SIDING AT REMOVED FASTENERS OF NE\N T45DR41NNG6 lNSIRUMENTOF SERNC DREMNN5TNEPNOPE 0FLPCHOPELLE ARCNR D.NtE PLLC REGMDLE55 OF WHERIERTIIE PPOIECf FOR WIIICN R IS PPEPARED IS E%ECDIEO.NO CHnNGEG,ALTEPAli0N5,0ft DDETIONS MAYOE MODE FSCFPTBY IPCf41Pf11E pRGUIECTME PLLD.TILLS DPF.WING MATNOTeE ICED DTOMFR PORRE9 PoP GMFRPROlEC15. O f011RDDR10N R11Hb PROIECTGY OTIYA PORf1E5,MfGRCOMPLEDON OYTI65 PRD1ECI RY OINDI PAR11E9,1NTN W T TXE NN REN CONSEM OF lAG W f31E NRCHRECiUFL PLLL —————————— mCOPYPJGM]031ILDlNPELLEiRCHRECNPEPLLC SOUTH &WEST ELEVATIONS Em- - SHEET NO: EXISTING ELECTRIC SERVICE METER, REPLACE ALUMINUM LOUVER O2 WEST ELEVATION GENERATOR CONNECTION,AND A10,00 SCALE: 1/4" = T-0° OTHER UTILITIES SHEET 10 OF 12 NOTE:THOUGH MAKE AND MODEL ARE PROVIDED FOR GEROSA/BULIS SOME APPLIANCES AND FIXTURES, PLEASE COORDINATE APPROX.30"x30"GLASS WITH OWNER AS SELECTIONS MAY CHANGE MODIFY EXISTING SHOWER ENCLOSURE RESIDENCE CROWN MOLDING VENTING TO ALLOW HARDIBACKER SUBSTRATE 605 CIRCLE DRIVE 0 A Y 3 RECESSED FOR SHOWER INSERT ON EAS M RION N 119 9 o 0 0 0 ....... MEDICINE CABINET 7715f TWO SIDES AND FLOOR ' KETCHAM DELUXE A w SERIES MEDICINE NEW 2x6 "-'- CABINET,24"X30", BLOCKING AT SKIM&PAINT EXPOSED GWB APPROX. , .. . WALLS&CEILING I I POLISHED EDGE, SHOWER HEAD � 24"x18"VANITY RECESSED a AND MIXER uO PTD.WOOD WAINSCOTING TRUENO a RTH O °,a„ 9 ° KOHLER HIGHLINE ❑ 9 o °'- ARC ROUND- 32'k32"SHOWER REPLACE GWB IN BATHROOMS (WALLS&CEILING) FRONT SINGLE BASE&BACKWALL PROJECT �° gIts /F R77 PROVIDE 2x6 BLOCKING AT NORTH , FLUSH TOILET KIT (3384') Q q . TOWEL RACKS&TOILET PAPER "° � (K-78279) HOLDER TAX MAP SCTM#-1000-21.3-7 5-�2 6'-0" k 5'-62' 6'-0" OBATHROOM 1 - NORTH BATHROOM 1 - EAST BATHROOM 1 - SOUTH BATHROOM 1 - WEST # ISSUE/REVISION DATE SCALE: 1/4" = T-0" O SCALE: 1/4" = T-0" O SCALE: 1/4" = T-0" O SCALE: 1/4" = T-0" .00 FILING SET 12.12.2023 HARDIBACKER SUBSTRATE FOR NEW TILE ON THREE SIDES CROWN MOLDING • DRAWN BY:J LACHAPELLE n C CHECKED BY•J LACHAPELLE NEW 2x6 MOUNT 48„�8„ 00000000 BLOCKING i, FRAMED MIRROR : SKIM&PAINT EXPOSED GWB NOTE:THIS IS AN11"x17^SHEET �-' AT SHOWER WALLS DRAWINGS MAY BE PRINTED NOT TO SCALE KOHLER PTD.WOOD WAINSCOTING HEAD AND .0.. MIXER/ ARC HIGHLINE LaChapelle Architecture PLLC DIVERTER REPLACE GWB IN BATHROOMS P.O.Box 1251 ELONGATED ° `''- BOWL (WALLS&CEILING) Mattituck,NY 11952 °-'- PROTECT SINGLE PROVIDE 2x6 BLOCKING AT (646)251-5058 jake@lachapellearchitecture.com EXIST.TUB; FLUSH TOWEL RACKS&TOILET PAPER REPAIR TOILET HOLDER �- T-71" 2'-6" `,I RUST 4'4' -;� (K-78279) 2'-6" �. 7'-741 4,��1 ED O5 BATHROOM 2 -NORTH DRAINAROUND 6 BATHROOM 2 - EAST BATHROOM 2 - SOUTH 8 BATHROOM 2 - WEST ��`'��RAC/_/ SCALE. 1/4 — 1 0 O SCALE: 1/4" — 1 -0 O SCALE: 1/4" = T-O" O SCALE: 1/4" = T-O" �� �(Irl C) 1a GE JVM6175YKFS UPPER CABINET MICROWAVE OVER REFRIG. do GE GAS640RMSS NEW o�O c GAS RANGE ------------ -----1 UNDERMOUNTI I a = I % f FULL DEPTH I I I rwso umrva lsax wsmumEN opsEm cE ANoaEmpnu HE PNOPEm ar ucwPEua ARCNNECTU(@ PLLC REOARO----ER THE PAOIECT EOP YRCCH"IS PREPAAEO IS EaCUTEp.NO CHM2GF5,WEFA,IONS,OROELFIIONS MAYBE MADE F%CEDE BTIACENPELLE 1O " SINK REFRIG. I LACNNECTCRE P"f.TH6 DMNiND MATNOT DE USED BT DTXER PARfIE9 E0ROIXEi1PHOlEC,S, 611 I !�W0.PDiRIOE8,1YtI��'211EYMirENPW�"xSQRaF'IACN�4PEL�'LE'ARC"DEhME'�PLLC.N' ®CCIY 1 M2022LICHAP ARCHNECTUREP ® Q• m® Cf.) I I I REMOVE GWB I I INTERIOR o AND PROVIDE ELEVATIONS • 2x6 BLOCKING 18"DISHWASHER ® _________—______ AS NEC.FOR J 11. 11 1.02 '_0'1 �1�9 2'-0" �2'-6'� 2'-02" 141 — 2'-0" — CABINETS �1'-0"� 3'-0 2'-7"--� 1'-10" SHEET NO: O KITCHEN EA1T 10 KITCHEN SOUTH 11SCALE:KITCHEN E SCALE: _ 0I SCALE: _ _O" %4 — 1 —01 A1l.00 SHEET 11 OF 12 4 FRAME OR BLOCK TO G EROSA/RU LIS EXISTING JOISTS RESIDENCE BATHROOMS: ;:,<; TYPICAL ROOMS: 605 CIRCLE DRIVE 2'GYPSUM BOARD AT NEW == PROTECT AND PATCH ADJACENT EAST MARION,NY 11939 BATHROOMS CEILINGS;SKIM, -`s PRIME,&PAINT EXISTING GWB CEILINGS USE e"HARDIBACKER BOARD AT 5 CROWN AND BASE MOLDING PER p�p WALLS RECEIVING TILE;GWB OWNER 0 ELSEWHERE 8'GYPSUM WALL BOARD;SKIM, TRUE 0 oa q o WAINSCOTTING IN BATHROOMS PRIME,&PAINT-WHERE REPLACED NORTH MINERAL WOOL BATT INSULATION AT PERIMETER WALLS TO FILL CAVITIES (R13); MINERAL WOOL SOUND BATT NORTHcr O ® q VINYL PLANK INTERLOCKING _ AT NEW BEDROOM 2 INTERIOR WALLS (33.84°) Q0 O FLOORING 0, WOOD 2x4 FRAMING AT INTERIOR TAX MAP SCTM#-1000.21.3 7 SOUND-ABSORBENT PARTITIONS; USE SELECT UNDERLAYMENT STRUCTURAL TO MINIMIZE # ISSUE/REVISION DATE WOOD THRESHOLD OUT-OF-PLANE ISSUES IN NEW WALL oo FLUNG SET 12.12.2023 SEAL AT BASE AND HEAD OF WALL AND REFINISH ADJACENT AT ALL PENETRATIONS PER CODE, WOOD FLOOR PRIOR TO APPLICATION OF TRIM EXISTING WOOD SUBFLOOR REFINISH EXISTING WOOD FLOORS, REPLACE AS NECESSARY FASTEN STANDOFF SIMPSON(OR SIM.) DRAWN BY:J.LACHAPELLE Um umm BASE TO EXISTING GALV.STANDOFF BASE CHECKED BY:J.LACHAPELLE GIRDER OR JOIST; CAST INTO OR EPDXY NOTESHIM TO TRANSFER BOLTED(MIN. EMBED DRAWINGS S IMAY A BE PRINTED SHEEP DRAWINGS MAYBE PRINTED NOT TO SCALE EXISTING JOISTS LOAD 8")INTO FOOTING WINDOWS&DOORS: PROVIDE 4"x1"INTERIOR TRIM,PLUS 3i CORNER MOLDING(RBS WM2O6 OR SIM.)AT PERIMETER 4 10"D►A. LaChapelle Architecture PLLC O TYPICAL PARTITION DETAIL -1-1"x 44' CONCRETE P.O.Box 1251 SILL(RBS WOWSOO2 OR SIM.)AT WINDOWS SCALE: 3" _ T-O" -5"APRON ATWINDOWS BARS0 PIER; (TO'L' 8jake@lach 11952 o (646)251-5058 jakeQlachapellearchitecture.com FOOTING; 3,000 PSF MIN. I° 18"x18"x12" �cR ADH RC` SQUARE �� �� 4,oF'yi� FOOTING; lc� r °d I ° ° I' REINFORCED `'� -4 w(2)#4 BAR I P d d . ° ;I IN EACH s DIRECTION; y �, 3,000 PSF �F 03393� ° ° MIN. OF NEW ° °' e\ Y/ rxas DRnwlrDls nn ttuTRBNErrt aE SERvxEwNDRENurrtrNE PROPrnrc orExRaPEUE ° MEC PLLC REO°RDLP 0 YMElMERTiEPR01ECYPCRWM lH PRE EDES '° ENECUEEO.NO CX°NGEB,°EIERNRON;OR DElEfIONSNAY BE MPOE FXCEPf BYIACHAPELLE d '� � 1RCpfECfURE RLC.iNIBDMVNIG MAYMOEBEVEFO BY OMER PMYIEE fOROfiffA PROIECl0, f011 POORIONTDTHIS PROrtCi BY OO&R PARIIES.OR FOR[OMPlEf10N OPTHIS PR0IECT BY ' / \ OMER PFRREB,WIfX0Uf 1NE WNIYERCONSENYOPIKHMELLENKfPfELNl0:PLLC. ..G d ®COPYi00M]D]0 L°CN°PELLFPRMRELfIIREPLIC DETAILS SET CONCRETE FOOTING ON UNDISTURBED SOIL SHEET NO: O TCALEAL FOOTLING DETAIL Al2,00 SHEET 12 OF 12