Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
49847-Z
gOFFOIkc Town of Southold �A o 10/12/2024 ao Gym P.O.Box 1179 o _ 53095 Main Rd Southold,New York 11971 4'flpl ��r CERTIFICATE OF OCCUPANCY No: 45648 Date: 10/12/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1700 Inlet Way, Southold SCTM#: 473889 Sec/Block/Lot: 92.4-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/19/2023 pursuant to which Building Permit No. 49847 dated 10/6/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Kaplan,David&Elayna of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49847 3/26/2024 PLUMBERS CERTIFICATION DATED zi Autfioriz&Signature �4�S�FEat�,co t TOWN OF SOUTHOLD oy� BUILDING DEPARTMENT x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF'APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49847 Date: 10/6/2023 Permission is hereby granted to: -Kaplan, David 25 Woodgreen Ln East Hills, NY 11577 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. r At premises located at: 1700 Inlet Way, Southold SCTM #473889 Sec/Block/Lot# 92.-1-7 Pursuant to application dated 9/19/2023 and approved by the Building Inspector. To expire on 4/612025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 1 Building Inspector. . t: pF SO!/Tyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road CO- P.O.Box 1179 �o sean.devlina-town.southold.ny.us Southold,NY 11971-0959 O. cOUNT`I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: David .Kaplan Address: 1700 Inlet Way city:Southold st: NY zip: 11971 Building Permit#: 49847 Section: 92 Block: 1 Lot: 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: EmPower CES License No: 65990ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 10.4kW Roof Mopunted PV Solar Energy System w/ (26)SPR-400W ACPV Modules, AC Combiner Panel w/ (4)20A 22013reakers & 60A Main, SunPower Monitor Notes: Solar Inspector Signature: Date: March 26, 2024 S. Devlin-Cert Electrical Compliance Form fq so 7 t 70c� TOWN OF OUTHOLD BUILDING DE PT. "COY 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ .] .FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ . ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: J�IVA-t/ V.AnEZ.;M fC, DATE INSPECTOR 1 �NOF SO(/Th°� # # TOWN OF-SOUTHOLD,BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND . [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL gd/a,r— [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) , - [ .] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: L C WI v l ns b&A DATE INSPECTOR ?IELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) OC1 ------------------------------------- FOUNDATION (2ND) z o H 1 ROUGH FRAMING& 1 PLUMBING 1 INSULATION PER N.Y. STATE ENERGY CODE t,/s Ito¢ �•sihCc . CIA. 2 C O. joee 44 FINAL 0•//a ADDITIONAL COMME TS LiI�1��� E� L _ C +d ri s ° rn C � �b z x C .d H ��o�Su+Fnc,r�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.aov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D PERMIT NO. Building Inspector: SEP 1 9 2023' Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is'not the owner,an., Building Department Owner's-Authorization form(Page 2)shall be completed. Town of Southold Date: OWNER(S)OF PROPERTY: Name: David Kaplan SCTM#1000-092.00-01.00-007.000 Project Address:1700 Inlet Way_, Southhold, NY 11971 Phone#: 5.1.6.6-8.0_6.85.0 Email:criLaplan,@.p.r)toriline.net Mailing Address: 1700 Inlet Way, Southhold, NY 11971 CONTACT PERSON: Name: Ines Fernandez (EmPower CES, LLC.) Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESIGN PROFESSIONAL INFORMATION: Name: Gregory. D. Sachs Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com CONTRACTOR INFORMATION: Name: EmPower CES, LLC. Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 Email: permitting@empower-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 20ther Roof mounted solar panels $30,914.25 Will the lot be re-graded? ❑Yes 1XNo Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property: Residential 1_Family Intended use of property: Residential 1 Family Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑YesXNo IF YES, PROVIDE A COPY. IN Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION 15 HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Ines Fernandez RAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) Ines Fernandez being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Ryan M.Moser NOTARY PUBLIC,STATE OF NEW YORK day of ,20 Z3 Registration No. 01M06412506 Commissip fagamber 28,2024 PROPERTY OWNER AUTHORIZ N (Where the applicant is not the owner) I� David Kaplan residing at 1700 Inlet Way, Southhold, NY 11971 do hereby authorize Ines Fernandez . to apply on my behalf to th T of Southold Building Department for approval as described herein. J15L 3 0 ignature Date �11 �Ah Print Owner's Name 2 I ;�.•OFF04t . BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 co Southold, New York 1197'1-0959 �. �b : ' Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCa)southoldtownny.gov= seand(&-southoldtownny.gov f APPLICATION FOR ELECTRICAL INSPECTION -` ELECTRICIAN INFORMATION (All Information Required) Date: 1/11/2022 Company Name: _EmP_ower CES,_LLC. Name: -Timothy Crott License No.: ME-65990 email: ermittin e_m_ ower-solar.com Address:_ 4589 Austin Blvd,.,`Island_Par k,_NY 11558__. Phone No.: (516)-544-4592 JOB SITE INFORMATION (All Information Required) Name: David Kaplan--.- Address: - 1700-Inlet Wa _-Southhold NY 11971 Cross Street: ' Phone No.:_ (516) 680-6850 _ Y Bldg.Permit#: Cn email:djkaplah@optpplinp.net Tax Map District:_ 1000. SecIliori 092.0-0— Block: 01.00 Lot:007.0.00 BRIEF DESCRIPTION OF WORK (Please Print Clearly) _ a Installation of_roof-mounted solar-panels_(Zs)SPR-400w ACPV_modules 10.40kW total system size, i Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued,On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _ -A # Meters _ Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional_Information:` - PAYMENT_D.UE-WITH-APPLICATION Request for Inspection Formals SURVEY OF PROPERTY CEDAR POINT DRIVE EAST SITUATED AT BAYVIEW TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-92-01-07 A SCALE 1"=20' 41 NOVEMBER 15, 2006 AUGUST 24. 2021 UPDATE SURVEY AND ADD PROPOSED ADDITIONS t l AREA = 16,744 sq. ft. q Oo nE UNO 0.384 ae. w,N �' �p• CERTIFIED TO: ''r d`• "•e: �. BARBARA ANN KAPLAN BARBARA ANN KAPLAN,AS TRUSTEE OF THE TRUST AGREEMENT DATED MAY 15. 1996 ,j� KNOWN AS THE ROBERT AND BARBARA KAPLAN PERSONAL RESIDENCE TRUST No. 1 . .••`• •rd� �� NOTE: ' LOT NUMBERS SHOWN REFER TO MAP No. 1 OF EDWIN H. BROWN, FILLED �NaAP, IN THE OFFICE OF THE CLERK OF SUFFOLK COUNTY AS MAP No. 802 AND TO MAP OF CEDAR BEACH PARK, FILLED IN THE OFFICE OF THE CLERK OF SUFFOLK COUNTY AS MAP No. 90 m o QD d8 41 41 y 0 s U6• \e O S ', •�J. t�9 r .000 vn oN' ,s d QP � LOT a.� �Oe �� g gy sl 60T gs yRP 0 Q� r mt f 2g p �tl L 4�V s�•�saiw.Tmramrs�""�a�s N 7 4.0745" OF g< y� 127 39, �, 5 '" N.YS.U<.No.504e7 Nathan Taft Corwin III , at Land Surveyor �Nra v.rvtlogs aa®scv_m -oIm1E dosepn� Suvssm Tm.=J.bvgm.Jr-LA A In9e9no LS. i vExs�x�ox m1 nm vm�iEY LHe Slvrep 52.flan.— C—ft tr'on LOwA 'imLt 4ID pg�aa„lsim 1awx um PHONE I27-2090 Fa[(631)27-1727 M. NFCLS MAD AT NA9LVC ADDRESS THE m W W o 19A'SsrnAOE 1599 U.In Rood P.O.0.16 THE OxSTQICE OP OpR W MfAYS Ja_V.,•Nn Yoh 11947 Ja wort.N-Yoh 11947 ANO/00.-um'cN1s O7 ecmw.V ANI.XOi SN9MN ARE NOi UX;NW . E-Yml:NCanL.TOvd.can 26-362A NYSIF PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nySlf.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A A 522407627 Miff... m AMWINS BROKERAGE OF NEW YORK 200 ELWOOD DAVIS ROAD SUITE 200 LIVERPOOL NY 13088 0• V SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER EMPOWER CES LLC TOWN OF SOUTHOLD 4589 AUSTIN BLVD 54375 ROUTE 25 ISLAND PARK NY 11558 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2546 624-4 256986 05/01/2023 TO 05/01/2024 04/25/2023 THIS IS'TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO: 2546 624-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY AFFORDS COVERAGE TO THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. DAVID SCHIEREN GREG SACHS EMPOWER CES LLC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,I(URANCE FUND UNDERWRITING VALIDATION NUMBER: 1057999100 litlipi�II�100000000000114 8356911I1I1 Form WC-CERT-NOPRINT Version 3(08/29)2019)[}VC Policy-25466244) U-26.3 69 [00000000000114B35691][0001-000025466244][#*2][16124-21)[CerLNoP-CERT_1][01-00001] i Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name I� GREGORY SACHS Business Name s certifies that the firer is duly licensed EMPOWER CES LLC DBA :he County of suffolk License Number: H-50211 Rosalie Drago Issued: 06/30/2012 Commissioner Expires: 5/1/2024 Suffolk County Dept.of �.; Labor,Licensing&Consumer_Affairs a MASTER ELECTRICAL LICENSE Name TIMOTHY M GROTTY Business Name This certifies that the Empower CES LLC DBA nearer is duly licensed :)y the County of suffolk • License Number:ME-65990 Rosalie Drago Issued: 1"/12/2021 Commissioner Expires: 11/01/2023 ' c J , 1 2 3 4 5 6 7 8 9 10 11 12 13 UTILITY EMPOWER METER S O L A R I I O 4589 AUSTIN BLVD o ISLAND PARK,NY 11558 TO TEL:516-837-3459 UTILITY FAX:516-706-1789 GRID www.empower-solar.com BRANCH C BRANCH B BRANCH A � � (7)SPR40OW MODULES - (9)SPR40OW MODULES (10)SPR-40OW MODULES THE INFORMATION DISCLOSED HEREIN IS THE SOLE H TOTAL DC STC POWER:2.80 kW TOTAL OC STC POWER:3.60 kW TOTAL DC STC POWER:4.0 kW H PROPERDUC IONO R CET,LLGTION OF THIS ENPHASE IQ7HS-66 MICRO INV 9 ENPHASE IQ7HS-66 MICRO INV 10 ENPHASE IQ7HS-66 MICRO INV Li L2 N REPRODUCTION OR DISTRIBUTION OF THIS (7) () ( ) MATERIAL IS STRICTLY PROHIBITED WITHOUT TOTAL AC POWER:2.688 kW TOTAL AC POWER:3.456 kW TOTAL AC POWER:3.84 kW CT AC4 PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIO CONTINUE AS CONTINUEAS CONTINUEAS REQUIRED FOR INV.... REQUIRED FOR INV.... REQUIRED FOR INV.... SPECIFIED STRINGING SPECIFIED STRINGING SPECIFIED STRINGING G AC7 AC1 AC1 n G OF //��(� (1)SPR40OW MODULE (1)SPR40OW MODULE (1)SPR40OW MODULE TO �� o?,Y D �O (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2 HOUSE oo LOADS AC1 AC1 AC1 F (1)SPR40OW MODULE (1)SPR40OW MODULE (1)SPR40OW MODULE Z �- (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 MAIN SERVICE PANEL . V Li Act Act Act 1 -PHASE 120/240V �OFEsslo'A � E SUNPOWER E DATA AC DISCONNE MONITORINGWLIL2 60A,2P CB LABEL DESCRIPTION LABEL DESCRIPTION AC1 SPR AC CABLE AC2 1"PVC ,2P CB(2)#12 AWG (6)#10 AWG D REV: DESCRIPTION: DATE: D (1)#10 AWG,EGC20A,2P CB G AC3 PROJECT NAME: AC3 3/4"PVC AC4 1 1/4"PVC TO RACKING (3)#10 AWG (3)#6 AWG GROUND NEMA 3R r' 20A,2P CB (1)#10 AWG,EGC (1)#4 AWG,GEC KAPLAN RESIDENCE ENCLOSURE (1)#6 AWG, EGC n 20A,2P C PROJECT LOCATION: C C 1700 INLET WAY SOUTHOLD,NY 11971 AC2 PROJECT* PROJ.PHASE: PERMIT DATE: 09/08/2022 NOTES: B g DESIGNED BY: N 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) CHECKED BY: XX 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 1 Jill SCALE: NTS 4.SIZE GEC AND EGC AS PER NEC 240.66.NEC240.122 RESPECTIVELY TITLE: 5.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. THREE LINE AC COMBINING MLO PANEL ELECTRICAL SCHEMATIC TOTAL SYSTEM SIZE: 10.40 kW 1-PHASE 120/240V A (26)SPR-40OW MODULES A SHEET: (26)ENPHASE IQ7HS-66 MICRO-INV. S E-02 1 2 3 4 5 6 7 8 9 10 11 12 13 OCCUPANCY OR APPROVED AS NOTED IS UNLAWFUL DATE• o- 3 B.P� � USE LATE ��BY: _ WITHOUT CERTIFICATE NOTIFY BUILDING DEPARTMENTAT OF OCCUPANCY 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION cofwKy 4. FINAL-CONSTRUCTION MUST VEW YORK STATE gr'low .C'�OF 8E COMPLETE FOR C.O. ODE$ _ ALL CONSTRUCTION SHALL MEET THE AS REQUIRED.:AND CdNR�TIONS OF REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS SOUTHbID T41MV PLANNIN 'S1iNOlOTOWN;TR ,STEES RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. i 4 Gregory Sachs, PE 4589 Austin Blvd, (516)-544-4115 Island Park, NY 11558 permitting@empower-solar.com September 8,2023 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 1700 INLET WAY,SOUTHHOLD,NY 11971 can support the additional load of the solar energy system, in addition to wind,snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar energy system installation. Table 1 Rafter Snow Wind Max Span Layers of Roof Surface (ft) spacing Cross Section Load Speed Kneewall Collar Ties Shingles (in) (psf) (mph) Flat 1 21.00 16 Nominal 2x12 20 130 No No 1 Sincerely, Gregory Sachs, PE 0F NEW Y D. rOD w 0 4531 AROFESS\O�P Gregory Sachs, PE 999 Stewart Avenue (516)-544-4592 Suite 210 permitting@empower-solar.com Bethpage, NY 11714 June 27th, 2024 D E C E u V E Town of Southold JUL - 1 2024 Building Department 54375 Route 25 Building Department Southold, NY 11971 Town of Southold Permit#:49847 1700 Inlet Way Southold, NY 11971 Section: 092.00 Block:01.00 Lot:007.000 To Whom It May Concern: The Solar Electric installation at 1700 Inlet Way, Southold, NY 11971 ( Kaplan Residence) has been inspected and meets the New York State Building Code standards for construction and the provisions of ASCE 7.The solar panels have been secured to the roof as per the manufacturer's attachment detail shown on the approved drawings, and are in compliance with the structural engineer's requirements.The project is consistent with the specifications set forth in the permit application. Sincerely, If OR sac O Q�•,f e w �__. • Y t� • ^ 2Q {�cFNS-DP" Gregory Sachs, PE 1 2 3 4 5 8 - 7 •8 9 10 11 12 13 - - EMPOWEP SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL:516-837-3459 RESIDENTIAL FAX:www.empower-solar.com 6-706-1789 www.empower-solar.com H SOLAR PROJECT H PROPERTYME INFORMTIONPoWER CLOSEDCIES.LLC.UIN IS THE SOLE OF EMIZE REPRODUCTION OR DISTRIBUTION OF THIS PROJECT TEAM. MATERIAL SPECIFIC PERMISSION N PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL OWNER: David Kaplan R Y * AGO 'D S, PHONE: (516)680-6850 ENGINEER OF RECORD: �� 1 ,v 7♦ F SOLAR INSTALLER: GREGORY SACHS,PE F m EMPOWER SOLAR N _ 1 W 4589 AUSTIN BLVD 4589 AUSTIN BLVD ISLAND PARK,NY 11558 V ISLAND PARK,NY 11558 5 3� PHONE:516-837-3459 E O�s r- PHONE:516-837-3459 E SlON D `�,'�• D REV: DESCRIPTION: DATE: PROJECT LOCATION DATA: SHEET INDEX: PROJECT NAME: David Kaplan ADDRESS:1700 Inlet Way,Southhold, ST-01 COVER SHEET # f •., `�'r �' i NY 11971 S-01 EQUIPMENT LOCATIONS PROJECT LOCATION: S-02 STRUCTURAL 1700 Inlet Way,Southhold, C SE-01 ELECTRICAL C NY 11971 SCTM:1000-092.00-01.00-007.000 PROJECT#. PROD.PHASE: PERMIT DATE: 8/30/2023 BElio B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS MAP TITLE: COVER SHEET A A SHEET: ST-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 AV EMPOWER SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 TEL:516-837-3459 FAX:516-706-1789 www.e m p o w e r-soI ar.eom SETBACK LEGEND THE INFORMATION DOOMED HEREIN M THE SOLE H ® z H PROPERTYOFEMPOWER CES,LLC.UNAUTHORRED 3611 CLEAR PATH REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION T PROFESSIONALS 5 ® 18"RIDGE SETBACK 1 � 1 G 4 ® ACCESS ROOF G F 2 g'�PGpRY D �t0 F O FLAT-1 ROOF: �1°l _ 3 26 SUNPOWER 400W-ACPV-(WAR)PANELS _ TOTAL POWER:10.40 kW ^` ORIENTATION:157°;PITCH:0° '=� Q0 W+HA TYPE 2:ROOFTECH Q �-4 5 31 ` Q O SOLAR ACCESS:97% TSRF:81% E E O'�SSIONP�-� D DRIVEWAY D REV: DESCRIPTION: DATE: PROJECT NAME: EQUIPMENT LEGEND: KAPLAN RESIDENCE Ell MODULES PROJECT LOCATION: c OO c 17001NLET WAY SOUTHHOLD,NY 11971 2 UTILITY METER(EXTERIOR WALL) O PROJECT# PROJINVERTERS DATE.PHASE PERMIT DATE: 09/08/2023 B B DESIGNED BY: ED CHECKED BY: 4] SOLAR DISCONNECT(EXTERIOR WALL) S SCALE: NTs TITLE: MAIN SERVICE PANEL(INTERIOR WALL) EQUIPMENT LOCATIONS ROOF LAYOUT A NOT TO SCALE A SHEET: S-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 6 9 10 11 12 13 EMPOWER SOLAR VD SUNPOWER MODULES 4ND PARKAUST,NY 115 ISLAND PARK,NY 11558 0 ON INVISIMOUNT RACKING TEL:516-837-3459 SHINGLES FAX:516-706-1789 ww IN.em power-so I r.coIn H THE INFORIMTON DISCLOSED HEREIN LS THE SOLE RAFTERS H REPRO PRODUCTION ON 0 DISTRIBUTION UTION OFF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL *5 �GoRY6 TYPICAL ROOF SECTION -; ' co NOT TO SCALE (u A SUNPOWER PANEL SPECS ��c'•SS)3 N►�` E MODULE POWER(Wdc) QTY MODEL# LENGTH WIDTH DEPTH WEIGHT TABLE S-1.1:MAX.ATTACHMENT SPACING E C O SPR-400 26 SPR-M-SERIES-AC 73.7" 40.6" 1.57" 48.0 LB PORTRAIT: 5'-4" LANDSCAPE: 8'-0" SPR-A-SERIES-AC 72.2" .40.0" 1.57" 46.5 LB SPR-E/X-SERIES-AC 61.4" 41.2" 1.81" 42.9 LB D D REV: DESCRIPTION: DATE: NOTES: PROJECT NAME: 1. TOTAL SYSTEM DC POWER:10.40 kW 2.RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION David Kaplan MANUAL 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS PROJECT LOCATION: C AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED ACCORDING TO TABLE S-1.1 C 1700 Inlet Way,Southhold, 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS NY 11971 CODE REQUIREMENTS 5.INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6.SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT PROJECT#. ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROJ.PHASE: PERMIT BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE DATE: 8/30/2023 B TIME OF CONSTRUCTION B DESIGNED BY: ED 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, CHECKED BY: GS SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30- SCALE: NTS WIND LOADS -COMPONENTS AND CLADDING (C&C) AND FOR CONFORMANCE WITH THE TITLE: 2020 RESIDENTIAL CODE OF NEW YORK STATE.THIS CERTIFICATION DOES NOT APPLY TO STRUCTURAL ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION A 8.THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A 9.REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA SHEET: S-02 1 2 3 4 6 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER NOTES: , SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o - 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR TEL:516-837-3459 ELECTRIC SYSTEM) FAX:516-706-1789 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-solar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING'SPLIT-BOLT CONNECTOR' H 3.IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE MAYBE H PROPERTYOFEEMNPOWEFCES,HEREIN Lc UNAUTH RUED REPRODUCTION OR DISTRIBUTION OF THIS DERIVED FROM MAIN SERVICE PANEL MATERIAL IS STRICTLY PROHIBITED WITHOUT 4.CONNECT UTILITY SIDE TO PANEL LUGS PRIOR SPECIFIC WR TEN PERMISSION PROFESSIONAL S 5.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 6.SIZE GEC AND EGC AS PER NEC 250.66,NEC 250.122 RESPECTIVELY — — 7.PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOLAR 250.64(B),NEC 250.120(C) G ARRAY 1 8.FINAL SCHEMATIC SPECIFIC TO THIS INSTALLATION AVAILABLE UPON ,��OF Nstp REQUEST '�PGOFtY INVERTER(S) AC DISCONNECT F A 0`8453% E E SION��'� ` STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D D REV: DESCRIPTION: DATE: PROJECT NAME: INTERIOR EXTERIOR INTERIOR EXTERIOR David Kaplan PROJECT LOCATION: C C 1700 Inlet Way,Southhold, MAIN TAP BREAKER MAIN NY 11971 SERVICE ENCLOSURE O 1 PANELETTE SERVICE G)PANEL PANEL PROJECTtk. UTILITY UTILITY PROJ.PHASE: PERMIT METER METER DATE: 8/30/2023 e B DESIGNED BY: ED 1 CHECKED BY: GS SCALE: NTS TITLE: ELECTRICAL A A SHEET: SE-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 UTILITY EMPOWER METER SOLAR I 0—To—> 4589AUSTINBLVD ND PARK,NY 11568 TEL:516-837-3459 UTILITY FAX:516-706-1789 BRANCH BRANCH BRANCH GRID www.empower-solar.com (7)SPR40OW MODULES (9)SPR-40OW MODULES (10)SPR40OW MODULES THE INFORMATION DISCLOSED HEREIN IS THE SOLE H TOTAL DC STC POWER:2.80 kW TOTAL DC STC POWER:3.60 kW TOTAL DC STC POWER:4.0 kW L1 L2 N H PROPERWOFEMPOWER CES.U.C.UNAUTHORIZED (7)ENPHASE IQ7HS-66 MICRO INV (9)ENPHASE IQ7HS-66 MICRO INV(10)ENPHASE IQ7HS-66 MICRO INV REPRODUCTION OR DISTRIBUTION OF THIS TOTAL AC POWER:2.688 kW TOTAL AC POWER:3.456 kW TOTAL AC POWER:3.84 kW G MATERIAL IS STRICTLY PROHIBITED WITHOUT A(A PRIOR SPECIFIC WRITTEN PERMISSION CONTINUE AS CONTINUEAS CONTINUEAS PROFESSIO REQUIRED FOR INV.... REQUIRED FOR INV.... REQUIRED FOR INV.... SPECIFIED STRINGING SPECIFIED STRINGING SPECIFIED STRINGING G AC1 AC1 AC1 G O C n r E� . (1)SPR40OW MODULE (1)SPR40OW MODULE (1)SPR-40OW MODULE TO QRy (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2 HOUSE_AC1 t—AC1 t—AC1 LOADS V 2 - (n F (1)SPR40OW MODULE (1)SPR40OW MODULE (1)SPR40OW MODULE (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 (1)ENPHASE MICRO INV. INV.1 Z _ MAIN SERVICE PANEL 0 ?.� _ C� Act Act Act 1 -PHASE 120/240V A 4 3 E SUNPOWER E RO�SSIONP� DATA AC DISCONNEC- MONITORING JUL2 60A,2P CB LABEL DESCRIPTION LABEL DESCRIPTION LL AC1 SPR AC CABLE AC2 1"PVC 15A,2P CB D (2)#12 AWG (6)#10 AWG (1)#10 AWG,EGG D REV: DESCRIPTION: DATE: AC3 3/4"PVC AC4 1 1/4"PVC G AC320A,2P CB TO RACKING PROJECT NAME: (3)#10 AWG (3)#6 AWG GROUND (1)#10 AWG,EGC (1)#4 AWG,GEC NEMA 3R 20A,2P CBKAPLAN RESIDENCE (1)#6 AWG,EGCTENCLOSURE 20A,2P CB PROJECT LOCATION: C C 1700 INLET WAY AC2 SOUTHOLD,NY 11971 PROJECT#: PROD.PHASE: PERMIT NOTES: DATE: 09/08/2022 B B DESIGNED BY: IV 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE CHECKED BY: XX 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) SCALE: NTS 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY 0-0-04 5.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. TITLE: THREE LINE AC COMBINING MLO PANEL ELECTRICAL SCHEMATIC TOTAL SYSTEM SIZE:10.40 kW 1 -PHASE 120/240V A (26)SPR-40OW MODULES A SHEET: (26)ENPHASE IQ7HS-66 MICRO-INV. S E-02 1 2 3 4 5 6 7 8 9 10 11 12 13 ARM SERIES wa AREE" WSMDi-395 to WSMDi-415 One with the sun I ELECTRICAL CHARACTERISTICS Pmax(W) Vmp(V) Imp(A) Isc(A) Voc(V) Models Module Eff.('Yo1 STC I NOCT STC NOCT STC NOCT STC NOCT STC NOCT WSMD-395 395 296.E 37.77 34.70 10.47 8.55 11.24 9.08 45.00 42.10 19.78 WSMD-400 400 300.6 38.00 34.90 10.54 8.62 11.32 9.14 45.22 42.30 20.03 WSMD-405 405 304.4 38,22 35.10 10,61 8.68 1 11.40 9.21 1 45.44 42.50 1 20.26 WSMD-410 410 308.2 38.44 35.30 10.68 8.74 11.48 9.27 45.66 42,70 20.53 WSMD-415 415 312.1 1 38.66 1 35.40 1 10.75 1 8.B1 11.57 9.34 1 45.88 42.90 20.78 `Standard Test Conditions(STCI-1 O00 W/m2 irradiance,Air Mass 1.5 and 25'C cell temperature.Nominal Operating Cell Temperature NO-800 W/m2 irradiance,Air Mass 1.5,Ambient temperature 20T and Wind speed 1 ills. Average power reduction of 4.5%at 200 W/m2 as per IEC 60904-1.Measuring Uncertainty±3%. System Voltage 11500 V Series Fuse Rating 22 A I MECHANICAL CHARACTERISTICS Length x Width x Thickness(L x W x T) 1924 mm(L)x 1038 mm(W)x 35 mm IT) Weight 22 k s Solar Cells per Module(Units)/Arrangement 132 cells/(11x6 I 1 11x6) Solar Cell Type&Size Mono PERC,B3 x 166 mm Front Glass 3.2 mm Low Iron and Tempered glass with ARC coating Encapsulate PID Free&UV Resistant Junction Box(Protection degree/Material l IP613/Weatherproof PPO Cable&Connector(Protection degree/Type) IP68 rated/Staubli MC4 Connector Cable cross-section&Length 4 mm'&1200mm Frame Anodized Aluminium Alloy,Anodization thickness>_15 micron Fire rating Type 2 I DESIGN SPECIFICATIONS THERMAL CHARACTERISTICS Temperature coefficient of Current(Iscl,a l%/aCI 0.055 I I Temperature coefficient of Voltage(Voc),B(91o/aCl -0.285 Temperature coefficient of Power(Pm),y(%/cCI -0.365 NOCT PC) 43±2 Operating temperature range('Cl 40 to 85 uar ,.00 • .00� - � � a i _ Waaree Energies Ltd.is amongst the top Solar Energy Companies and has the country's largest Solar PV Module manufacturing capacity of 5 GW.In addition,it 1 is committed to provide top notch EPC services, project development,rooftop solutions,solar water pumps and also in an Independent Power Producer.Waaree has its presence in over 325+locations nationally and 68 countries globally. .If you need specific product certificates.and if module installations are to deviate from our guidance specified in our installation manual,please contact your local Waaree sales and technical representatives. 12 Years Product Warranty •27 Years Power Output Warranty •The electrical data given here is for reference purpose only. •Please confirm your exact requirements with the sales representative while placing your order. •Refer installation Manual instructions&Wearee warranty statement for terms&conditions. •Waaree Reserves the right to change the specifications without prior notice.z www.waaree.com - WEUE&PD/395-415/132/MP/HC/CMZ/01/27.07.2022 Data Sheet Enphase Microinverters Region:AMERICAS Enphase IQ7HS The high-powered smart grid-ready Microinverter Enphase IQ7HS Microinverter' with integrated MC4 connectors dramatically simplify the installation process while achieving the highest system efficiency. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014,2017&2020) Efficient and Reliable Optimized for high powered 66-cell*modules • Highest CEC efficiency of 97.0% More than a million hours of testing Class II double-insulated enclosure f. UL listed Smart Grid Ready Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) *The IQ7HS is required to support 66-cell modules. To learn more about Enphase offerings,visit enphase.com EN PHAS E. Enphase IQ7HS Microinverter INPUT DATA(DC) IQ7HS-66-M-US Commonly used module pairings' 320 W-460 W+ Module compatibility 66-cell PV modules Maximum input DC voltage 59 V Peak power tracking voltage 3B V-43 V Operating range 20 V-59 V Min/Max start voltage 30 V/59 V Max DC short circuit current(module Isc) 15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @240 VAC @208 VAC Peak output power 384 VA 369 VA Maximum continuous output power 384 VA 369 VA Nominal(L-L)voltage/rangez 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 1.60 A(240V) 1.77 A(208V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 to 68 Hz 47 to 68 Hz AC short circuit fault current over 3 cycles 4.82 A 4.82 A Maximum units per 20 A(L-L)branch circuits 10 9 Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V CEC weighted efficiency 97.0 i 96.5/, MECHANICAL DATA Ambient temperature range -400C to+60°C Relative humidity range 4%to 100%(condensing) Connector type Staubli made MC4 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA type 6/outdoor Altitude 2000m FEATURES ---------- --— _ _ . _. _ - — -- -- - ------- ---- Communication Power Line Communication(PLC) Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance CA Rule 21 (UL 1741-SA),HECO v1.1 UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014,NEC- 2017 section 690.12,NEC 2020 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. 1.No enforced DC/AC ratio.Seethe compatibility calculator at https7//enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com ©2022 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. *'� E N P H A S E 10-18-2022 u PH SunPowerO' Residential Simple and Fast Installation .; Integrated module-to-rail grounding Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even module spacing UL 2703 Listed integrated grounding Flexible Design - Addresses nearly all sloped residential roofs - Design in landscape and portrait with up to 8' rail span Pre-drilled rails and rail splice Rails enable easy obstacle management Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Elegant Simplicity Best-in-class system aesthetics Premium,low-profile design SunPowerc" InvisiMountTm is a SunPower-designed Black anodized components rail-based mounting system. The InvisiMount system Hidden mid clamps and new capped,flush addresses residential sloped roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. Part of Superior System The InvisiMount product was specifically envisioned and Built for use with SunPower DC and AC modules Best-in-class system reliability and aesthetics engineered to pair with SunPower modules.The resulting • New optional rooftop transition flashing,rail- system-level approach amplifies the aesthetic and mounted J-box,and wire management rail clips installation benefits—for homeowners and for installers. Combine with SunPower modules and SunPower FnergyLink'I monitoring app IMF s u n p o w e r.c o m InvisiMount Module'/Mid Clamp and Rail Module'/End Clamp and Rail Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly(for DCsystems only) sow 40* InvisiMount Component Details InvisiMount Operating Conditions Mid Clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature -401 C to 901 C(-40°F to 194'F) End Clamp Black anodized aluminum 6000 series 110 g(3.88 oz) 3000 Pa uplift Max Load(LRFD) 6000 Pa downfoi ie Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) Rail Splice Aluminum,alloy 6000 series 830 g/m(9 oz/ft) Ground Lug 304 stainless steel • Supported by Assembly (A2-70 bolt:tin-plated copper lug) 106.5 g/m(3.75 oz) Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal interface for other roof attachments InvisiMount Component LRFD Uplift 664 Ibf Mid Clamp Shear 5401bf InvisiMount Warranties And Certifications Uplift 899lbf 25-year product warranty End Clamp Warranties Shear 2201bf 5-year finish warranty Rail Moment:upward 548lbf-ft UL 2703 Listed Moment:downward 580lbf-ft Certifications • Class A Fro Rated Rail Splice Moment:upward 548 Ibf-ft Moment:downward 580 Ibf-ft • of Attachment Hardware Warranties Uplift 1000 Ibf L-foot Refer to roof attachment hardware manufacturer's documentation. Shear 390 Ibf 'Module frame that is compatible with the InvisiMount system required for hardware interoperability. z SunPower recommends that all Equinox"',InvisiMount'"",and AC module systems always be designed using the SunPower Design Tool.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD) design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPO\tVFR(1-800-786-7693). sunpower.com ,ation.AJI Rights Reserved.SUN POWER,the SUN POWER logo,EQUINOX,and IN - :-:,er Corporation. 509506 RevE he property of their respective owners.Specifications included in this datash:-