Loading...
HomeMy WebLinkAbout50723-Z �o�j1Su�FD pG.T Town of Southold 9/25/2024 a y� P.O.Box 1179 0 o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45582 Date: 9/25/2024 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 340 Sound Rd,Greenport SCTM#: 473889 Sec/Block/Lot: 35.4-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/12/2024 pursuant to which Building Permit No. 50723 dated 5/22/2024 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"mini-split system and"as built"combination boiler to existing;single-family dwellingas applied for. The certificate is issued to Porco,Josephine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50723 9/24/2024 PLUMBERS CERTIFICATION DATED t riz d Signature sgff lQ K o TOWN OF SOUTHOLD BUILDING DEPARTMENT Co y� TOWN CLERK'S OFFICE x "o • 4V SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50723 Date: 5/22/2024 Permission is hereby granted to: Porco, Josephine 18 Sound Rd Greenport, NY 11944 To: Legalize "as built" mini-split system and legalize "as built" combination boiler to an existing single-family dwelling as applied for per manufacturers specifications. Additional certification may be require. At premises located at: 340 Sound Rd, Greenport SCTM # 473889 Sec/Block/Lot# 35.-1-17 Pursuant to application dated 4/12/2024 and approved by the Building Inspector. To expire on 11/21/2025. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $500.00 ELECTRIC $200.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $800.00 0d) 0-� Building Inspector pF SO(/l�ol Town Hall Annex O Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 �� • �o Jamesh _southoldtownny.gov �yCOUNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Josphine Porco Address: 18 Sound Road city,Greenport st: New York zip: 11944 Building Permit* 50723 Section: 35 Block: 1 Lot: 17 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: HOMEOWNER Electrician: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition X Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 4 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 1 mini spli condeser and 4 blower heads Notes: HVAC MINI SPLITS Inspector Signature: eta40 Date: September 24, 2024 18 sound rd ho��OF SOGTy°� V a l7cV 0 If 50 ukn6t K * _ # -TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ .] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION = [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [x] ELECTRICAL (FINAL) [ ] ,CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �f��G /qc h c /-So/tfS Wit ,ate a -� ©V\. DATE 7-3 -of INSPECTOR x a +' .1 *r r• � i ' ' '� �.. '" �' !s {+. + ��� ALE }�l•� •�1 i , a ; • � .1 r � ` �• ► � P'. � it tat Or x Ti, f 1 e ° E t tf '10 + -I1 i 4� Y. ''155eee+' I4 `{ f s. �. cfl .;� tom.. � *• � "r� .� .� it 1p 1• FIELD INSPECTION REPORT DATE COMMENTS ul FOUNDATION(1ST) y ------------------------------------ n3 D FOUNDATION(2ND) ' T z 0 0 ROUGH FRAMING& y PLUMBING Q� 1 1 7 r INSULATION PER N.Y. STATE ENERGY CODE 4- FINAL ADDITIONAL C MMENTS n C (�• o, Z z � ro 11� z x r� �3 x t7 CrJ =oo�SUFFocK�oa TOWN OF SOUTHOLD—BUILDING DEPARTMENT H Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�o• �ao�� Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtowmy.gov f Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only t (� PERMIT NO. S v 7,;� ;J Building Inspector. 7� Q PR 12 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an ,�DII�T�A• o Owner's Authorization form'(Page 2)shall be completed. TDB^' ='I� 0a ;, Date: OWNER(S)OF PROPERTY: Name: -O I - -__QYG� SCTM#1000- 35'_ t 1 -7 ouK _ Project Address: Phone#: �j� ff— Email: Mailing Address: - IQ _— CONTACT PERSON: _ Name: T�Z Y 1� Mailing Address: Phone#: 20 Pt I Z Email: J P(f�Cv 2 (9 DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION . ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: l OtherSXlW O W% 9F C0w+X®-0o)\lei q V1 In'i - %D 10-S $ 1q,000 Will the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check,Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues.as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): ^ ,0 ❑Authorized Agent Rrowner Signature of Applicant: Date: I12 STATE OF NEW YORK) SS: COUNTY OFF Agh(yy, ��1((i0 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Vl (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her kn a and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn bjafore me this �[ day of 20-2 / o ry P Richard 0.Noncarrow Notary Public,State of New York 106 PROPERTY OWNER AUTHORIZATION No.01N Qualified in Suffolk Ctu 06224 County (Where the applicant is not the owner) MY Commission Expires June 2f,20 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector COG�.e TOWN OF SOUTHOLD co Town Hall Annex- 54375 Main Road - PO Box 1179 W ^ Southold, New York 11971-0959 c Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh southoldtownny.gov — seand(ab-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: 01rco Address: S B OL 4 Cross Street: Phone No.: 2V)2`+ �� 2 Bldg.Permit#: '��j email: \T,PLY-`p p @ yV-%0 J: Tax Map District: 1000 Section: 35 Block: ILot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): tStT�I\A t,� q YYl l trt i —S�1 fi S Square Footage: Circle All That Apply: Is job ready for inspection?: E YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES�O Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION r � 1 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 ^ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ja mesh(aD-southoldtownny.gov ^r seand( ,southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: I S 110t 4 4 Cross Street: Phone No.: L+ q- 1 Bldg.Permit #: Z`�j email: \3-,?pep 2 0 f ►tea& Tax Map District: 1000 Section: , S Block: Lot: 17 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): CX\ 4'V1I VA i Square Footage: Circle All That Apply: Is job ready for inspection?: ®YES ❑ NO ❑ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES �O' Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #-Meters Old:Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame M Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION c� l I PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TU B/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments 1't��s �' 4• MITSUBISHIELECTRIC - - SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSZ-GL06NA MSZ -:t -a;,;i •:; :.�'F - ::: .:;._-.. �SZ-GL.12NA MSZ :^,-.] c_..,;..•-,. . ir eTt OPERATING INSTRUCTIONS For":user, • .To use thisunitcoirectly andaafely,.b'e sure to read these operating in- structions:before;use' ��• _ ~MANUAL�DE;;INSi'RUCCIONES,'�: - '��`'� f ;Para, -� 'r • ' �'�"•f''` L t�' y' �,`Para`utilizer'esta unidad da',forma c'o recta y seguV'a, lea previamente" Espaflol ",; ':''estas'iristrueciohes''de'funcionamiento' -NQTICE.D'U'TILISAT ra ' - '. R` .a, �+'• } _{;,, ;',.'. ..,�;:" 'r 'A'•I'attention`'des client"s'' �. _ ION`•' ::;:Pour.;avoir,la!ceititude`d';utili5ei',cetappareil correctement-et en'toute- :', ,`secunte,_veuill'ez.lire cette:notice::d'instroctions avarit',de me.tre le'climati= - :seu�sous.terision ` =. L_ ` CODES` ..:,k:-•� ,..�. : ,. - .�,��°,.}�, co NEW YORK STATE:&TOWN CODES4;; ' _ 4r.�: '' :: : APPROVED AS-NOTED R UIRED ANDCONDITIONS:O :: a>' _ r!' _ =`"ti:.-, .J •.'tr�.-w.`�- fi-' -:�j,: :7�.vy." '.5'- •3 (I' k - - '( ii., .n[ .,;t, j:.,i t• -'„`11 4'' iL.(}'\�ti..i •.c>`v< J!°�..'.` /v': '1-J l'..., {u: •'-*R' If� •.�'��^ 8•p1 '� {fk( �}.. r_ ,••.7 r•--,� «+.,�Ay/U■�{y1�'1r�r{II��■tt�,wJ f�ry�Y11�1�1 �� » YWiw1W�1"�WHO 1r,' _ '�; �? `_..'- -^'r Yw•'tVYI�Y�n■FLAN�N!_V YY!��t .'t.,�. �P "';f-.t 'i i*'i�'' M f' •Y v. ' ;'i,rA�.L� r � yr:=:', °,1.• ',.,� �.':•�_��.:'".�% '�t �3 S�HOI��iIVN,Ti�EES:';rt-.�: _ - .4r - _ _ _ _ •a +s.7Fdti 'r- -n. .`�".--.- A'r _r+:;= "�:,' `_yr-��.t�- ;`S:A�,�•.^,' �j,- - bo �,'� ,'fit.--.:- _ - `•� ,! ,sl. LP_ - 4:•�' - f{i. .i r^� :�.•, .= ':; y� '.'NOTIFY BUILDING:DEPARTMENI'.A?' <63,1-765-1802-8AM .0 M,FOR-THE. :� '.1;. ;3�A�.t^ ct<::,=:.;:„ ,, ,{4, r•�� .ice, ''fah h ,�` �a �. -,,.- - r'rr u.`. WIN 'IN��P �N •i;;'r`;r'-,y;:<l,'; �-;:�';�' UI� J� - .,•.. `FOUNDA ON ,.'TWO Q RED` ,,.:-+r;-:,.�.•- " ,k,'''`"'.-. - 7- -tea•. AN IATION�� .J•SU ><tlo a Ad _A oNSTRUCTiON MUST - ..-. ;{•'� "i3; �•,i.,•'y;^.•s ^F Jrt�fication ;`, .. a:'._;;:'t _ __ COMPLETE FOR 0 O :. '. • tt ed e u>tr a'=Be�R ,N�s`� , .. y. ,Q ucoNSTAucno COCIES'OF NEW:: -- i: +:e4. �IBL:E'F R•' -R� A M. -'N �T ESPO`YO `ST 0 1 K TE•'• :I �•t •ROR$� UCTI�'N;ER , �ESIGN� NSTfI `D :OR.CO .. '4 L �ECIC TR ;. �.f �R E UIR N 4 SPE - _ N -I - - i'I`v� rt; �rj C v F•� _ tfY' °s - _ Y• S• •t ,S ".i ,4 - - d ,55 - L•V' ..t -.�.:.t.+_+`r,.•........xw.f.l::...._.-L..�:®.?...s.:.aw. - _. a.. ..].,.=�L.'t..=`_ _r'�"<•`1"s�:f-1.,41.:�!.�'-...ud>.wr.2'.t.u5:.1....':a.,.auiec `•.n+u...`^�...:.eLo...«ex - - 'v.�_.slm.1 1-2:SELECTING THE INSTALLATION LOCATION INDOORNote: ; • P Where airflow is not blocked. In rooms where inverter type fluorescent la ps Note: advisable to make a piping loop near outdoor unit YP m • Where cool(or warm)air spreads over the entire room. the signal from the wireless remote controller are used, nay not be so as to reduce vibration. • On a rigid wall to reduce the possibility of vibration. received. For increased efficiency, install the outdoor unit in a • Where it is not exposed to direct sunlight.Do not expose location where continuous direct sunlight or excessive to direct sunlight also during the period following unpack- OUTDOOR water can a avoided as much as possible. ing to before use. • Where it is not overly exposed to strong winds. If the • Where it can be easily drained. outdoor unit is exposed to a wind during defrosting,the Note: • At a distance 3 ft.(1 m)or more away from a TV and defrosting time will be longer. When operating the air conditioner in low outside tem- radio.Operation of the air conditioner may interfere with Where airflow is good and dustless. perature,be sure to follow the instructions described radio or TV reception.An amplifier may be required for Where neighbours are not annoyed by operation sound below. the affected device. I or hot(or cool)air. • Never install the outdoor unit in a place where its air • In a place as far away as possible from fluorescent and Where rigid wall or support is available to prevent the inlettoutlet side may be exposed directly to wind. incandescent lights(so the infrared remote control can increase of operation sound or vibration. • 'To prevent exposure to wind,install the outdoor unit operate the air conditioner normally). Where there is no risk of combustible gas leakage. with its air inlet side facing the wall and a baffle board • Where the air filter can be removed and replaced easily. If installing the unit in a location high above the ground, on the air outlet side. • Where it is away from the other heat or steam source. be sure to secure the unit legs. Avoid the following places for installation where air Note: Where it is at least 10 ft.(3 m)away from the antenna conditioner trouble is liable to occur. Install the indoor unit high on the wall where air can of TV set or radio.Operation of the air conditioner may Where flammable gas could leak. distribute over the entire room. interfere with radio or TV reception in areas where recep- Where there is an excessive amount of machine oil bon is weak.An amplifier may be required for the affected in the air. • •. device. Where oil is splashed or where the area is filled with • Where it is convenient to operate and easily visible. Install the unit horizontally. oily smoke(such as cooking areas and factories,in • Where children cannot easily touch it Please install it in an area not affected by snowfall or which the properties of plastic could be changed and • Select a position about 4 ft.(1.2 m)above the floor. blowing snow.In areas with heavy snow,please install damaged). Check that signals from the remote controller from a canopy,a pedestal and/or baffle boards. Salty places such as the seaside. that position are received by the indoor unit('beep' Where sulfide gas is generated such as hot spring, or'beep beep'receiving tone sounds).Then,attach sewage,waste water. remote controller holder to a pillar or wall'and install Where there is high-frequency or wireless equipment. wireless remote controller. Where there is emission of high levels of VOCs,includ- ing phthalate compounds,formaldehyde, etc.,which may cause chemical cracking. 1-3. SPECIFICATIONS 1-3-1. POWER SUPPLY AND INDOOR/OUTDOOR Electrical specifications WIRE CONNECTION MSZ-GL06NA MSZ-GL09NA MSZ-GL12NA MSZ-GL15NA • Power should be taken from an exclusive branched circuit. MODEL MSY-GL09NA MSY-GL12NA MSY-GL15NA a Wiring work should be based on applicable technical standards. INDOOR UNIT • Wiring connections should be made following the diagram. • Securely tighten screws. Power supply(V,PHASE,Hz) 208/230,1,60 Min.Circuit Ampacity (A) 1.0 Connecting wires and the ground wire Fan motor(F.L.A.) (A) 0.76 • Use solid conductor Min. AWG14 or stranded conductor Min.AWG14. OUTDOOR UNIT • Use double insulated copper wire with 600 V insulation. Power supply(V,PHASE,Hz) 208/230,1,60 • Use copper supply wire.Follow local electrical codes. Max.Fuse size(time delay)(A) 15 15 15 ' Power supply cable and ground wire Min.Circuit Ampacity (A) 9 9 10 • Use solid or stranded conductor Min.AWG14. Fan motor(F.L.A.) (A) ' 0.50 0.50 0.50 • Use copper supply wire. 'Follow local electrical codes. MSZ 6.2 6.6 7.4 (R.L.A)(A) MSY 4.9 4.9 6.8 Compressor Note: MSZ 7.7 8.2 9.3 When the indoor unit is powered from the outdoor unit,depend- (L'R'A)(A) MSY 6.1 6.1 8.5 ing on local code,a disconnect switch needs to be installed to a power supply circuit. Control voltage Inldoorounit t-Remote controller:(Wireless) Outdoor un t:DC12-24 V(Polar) ' MSZ-GL06NA is a dedicated indoor unit for multi system.Refer to the installation manual of the multi unit for details. 1-3-2. REFRIGERANT PIPES Minimum wall • To prevent condensation,insulate the two refrigerant pipes. Outside diameter thickness Insulation thickness Insulation material • Refrigerant pipe bending radius must be 4 in.(100 mm)or more. Pipe inch(mm) CAUTION For liquid 1/4(6.35) 0.0315(0.8) 5/16(8) Heat resistant foam Be sure to use the insulation of specified thickness(table on the 3/8(9.52) 0.0315(0.8) 5/16(8) plastic 0.045 Spe- right).Excessive insulation may cause incorrect installation of For gas cific gravity the indoor unit,and too little insulation may cause condensate 1/2(12.7) 0.0315(0.8) 5/16(8) to form. • The unit has flared connections on both indoor and outdoor Limits sides.• Remove the valve cover from the outdoor unit, 65 ft. 20 m_ then connect Pipe length MSZ/MSY-GL09/12/15NA ( )max. the pipe. Height difference MSZIMSY-GL09/12115NA 40 ft.(12 m)max. • Refrigerant pipes are used to connect the indoor and outdoor 10 max. units. No.of bends • Be careful not to crush or over bend the pipe in pipe bending. • Refrigerant adjustment...If pipe length exceeds 25 ft.(7.5 m), Up to 25 ft.(7.5 m) No additional charge is required. additional refrigerant(R410A)charge is required. Pip a length Additional charge is required. (The outdoor unit is charged with refrigerant for pipe length up Exceeding 25 ft.(7.5 m) to 25 ft.[7,5 m])to to the table below.) 20 g/m) Refrigerant to be added MSZ/MSY-GL09/12/15NA 1.08 oz each 5 ft.( I � J NCB Series Primary Manifold �Naviem Specification Sheet •Pipe manifold kit designed specifically for installations with Navien NCB Series combination boilers •Compatible with all NCB Series boiler models: NCB-180,NCB-180E,NCB-210,NCB-210E,NCB-240,NCB-240E •Compact design that is ideal for hydronic and radiant space heating applications •Package comes pre-assembled in order to reduce labor time and cost for installations while maximizing system efficiency without the need to fabricate a custom manifold •The SUPPLY and RETURN connections on the manifold attach directly onto the fittings located at the bottom of the boiler unit •This manifold kit contains the following features: -1"FNPT dielectric unions for the boiler SUPPLY and RETURN NCB Series Primary Manifold -1-1/4"sweat connections for heating SUPPLY and RETURN piping (#GFFM-MCOZUS-001) -Produced with durable L-copper piping -Shut-off valves provided for system isolation and ease of service -Two 1/4"service and drain ports and two 3/4"ports for use with heating system accessories •Weight: 9.0 lbs(4.1 kg) Installation Example � t ® Heating Supply♦• _- -- 4=Heating Return SUPPLY RETURN HOT COLD F/W — _ Hydronic Feed Water a r t Domestic Cold Water Supply Pump S Domestic Hot Water Supply Heating�•��i�lil--�® 5 f Heating Supply Check Return Valve Air Separator with Expansion Tank s maviem NCB Series Primary Manifold Specification Sheet Dimensions �3.50 2X V NPT DIELECTRIC UNION CONNECTION 3l4"FNPT WITH PLUG 2X 1/4"VENT&PURGE VALVE WITH 3/4"HOSE CAP &GASKET I 1"L COPPER \ 16.0 I 3/4"FNPT 1"L WITH PLUG I COPPER \ I 3/4"CTS ELBOW RED SLEEVES BLUE SLEEVES ON HANDLE ON HANDLE 1"L COPPER I 1"L COPPER 1-1/4"L COPPER NCB Series Primary Manifold s.o (#GFFM-MCOZUS-001) (all dimensions in inches) 14.a Available Connections on the NCB Series Primary Manifold For Optional Low Water Cut-Off or Temperature/PressureGauge O 0 Service/Drain Ports l Optional Port 0 0 • O 0 *Navien reserves the right to change specifications at any time without prior notice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.Navien.com Rev.5/16 i ®C�■i11�'�.�I�i ���11■�{ II''�'.0 _ � � �� ��II li=t�■,I,.._ I�1��.;. �--- i� ,��ice.��;�■b i`_ i•u� � �n[�Ilmtnlmmuln� ■ UK I 11/ •1 111 111 11/1 111 I I11 • ``: 111 11111 111 :1111 _•• .1 •I �1 : 1/1 1111 : /�)I •• •/1 s •- I MI.Ing. `KD THE LEADER IN CONDENSING TECHNOLOGY