Loading...
HomeMy WebLinkAbout50913-Z i2v- ��o�g11fFO4CpG� Town of Southold 9/13/2024 a P.O.Box 1179 ,- 0 co 53095 Main Rd �� � Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45545 Date: 9/13/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 595 Kerwin Blvd,Greenport SCTM#: 473889 Sec/Block/Lot: 53.-3-17.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/14/2024 pursuant to which Building Permit No. 50913 dated 7/9/2024 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar to existing single family dwelling as applied for. The certificate is issued to Clark,William of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50913 8/22/2024 PLUMBERS CERTIFICATION DATED Aut riz d Si n tore o�soEK TOWN OF SOUTHOLD �a BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE "oy • c��� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50913 Date: 7/9/2024 Permission is hereby granted to. Clark, William 595 Kerwin Blvd Greenport, NY 11944 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 595 Kerwin Blvd, Greenport SCTM #473889 Sec/Block/Lot# 53.-3-17.4 Pursuant to application dated 5/14/2024 and approved by the Building Inspector. To expire on 1/812026. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-RESIDENTIAL $100.00 Total: $325.00 Building Inspector pE SOUr�ol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �o sean.devlinc@-town.southold.ny.us Southold,NY 11971-0959 �yCOUNV5 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: William Clark Address: 595 Kerwin Blvd City:Greenport st: NY zip: 11944 Building Permit#: 50913 section: 53 Block: 3 Lot: 17.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy LLC License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump F1 Other Equipment: 6.8kW Roof Mounted PV Solar Energy System w/ (16)Jinko Solar JKM425-54HL4-B Modules, Enphase Combiner w/ (2)220Circuits & (1)115 for Monitor, On Backfed 30A Breaker Notes: Solar Inspector Signature: Date: August 22, 2024 S.Devlin-Cert Electrical Compliance Form Copy pf SOpT�°� # TOWN OF.SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION , [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL SO(A/ [ ] FIREPLACE & CHIMNEY [ '] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: l l X�� Ll dA t ) DATE SS INSPECT044 I*C OF SOUTyolo # TOWN OF SOUTHOLD BUILDING .DEPT. o m� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR� [ ] ROUGH PLBG. [ ] ,FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY : [ ] FIRE SAFETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL(ROUGH) `� ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE_C/O [ ] RENTAL REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) ---------------------------------------- FOUNDATION (2ND) —--------- ROUGH FRAMING & PLUMBING ----------- INSULATION PER N.Y. STATE ENERGY CODE lb,WTI FINAL ADDITIONAL COMMENTS Cp 97 4------ 0 rn ------------ ------------ TOE OF SOU T]EIOLD —BUILDING DEPARTMENT � C. Town Mall Annex 54375 Main road P. 0. Box 1179 Southold NY 11971-0959 'y�ol Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.izov Date Received I -';) E G7;11 E 0 W E APPLICATION FOR BUILDING PERMIT i For Office Use Only PERMITfVO. CO //3 Building Inspector: I 3A MAY 1 4 2024 Applications and forms must be filled out in their entirety.Incomplete appficatfans will not be accepted. There the Applicant is not the owner,an �Cii 161 f i �;r,,ir iic,s Owner's Authorization farm(Page 2)shall be complfted. Date: 5 & OWNER(S)OF PROPERTY: NameZCO-4 G6LKK— SCTM# 1000- bS3.00 -03 .00 -01-7 .v0 Project Address:S C1 1�"i n y N N r L 1 4 i Phone#: l- 2 - 7®y" Email: ��� �D4 S a's cS-Cc On Mailing Address: 5 OL 5 KxLywi-n $1 f , a _l CONTACT lal:@'i O N.- ;7 Name: LD rr A i'nf bs Mailing Address: -7 410 S UlAd 61VY2 ��.�-.�-1 �b y, �� Q j� Phone#: (.3 1 3 9 2 1-7 0.q / I Email: Parma 4,5 e, z,, . -D SIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: OmTRAcroR INFORMATION: Name: EA e�IneA Y)t,�m L4 Mailing Address: �or ?y v MA44 VCr, Nr Y/ I I q� Phone#: 62 0 , 39 -1 D 4 Email: DE:SCROPTION.OP PkOP65tD CONSTRUCTION ❑Blew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Will the lot be re-graded? ❑YesANo Will excess fill be removed from premises? ❑Yes);eNo I f 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? 1! s ❑No IF YES, PROVIDE A COPY. E]Xheck Box After Reading: The owner/contractor/desigq professional is responsible for alt drainage and storm water issues as provided by ' apter 236 of the Town Code.,APPLICATION IS HEREBY MADE to the Building Department for the'issuance of a"Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,Cdunty,,IUew York and other applicable Laws,Ordinances or RegulationsJai the constructiodof buildings,. .additions,alterations or'for removal or demolition as herein described.The applicant agrees t'o-cornply with all applicable laws,ordinances,building code,: housing code and regulations and,to admit authorized inspectors on premises and in 6uilding(s);for necessary inspections.False statements made herein are punishable as a Class A mis8emeanar pursuant to Section 21D 45 of the New York State Penal Law. Application Submitted B (print name):Lorraine Lorraine Di Penta pp Y�p ) ®Authorized Agent ❑Owner Signature of Applicant: �(�� �J � Date: Ll [ y STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine DI Penta being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this J 1 day ofIt�l . I 20_�:v 09 1A 0 Not y Public PROPERTY OWNER AUTHORIZ TIO DEBRAASEPULVE )A OTARY PUBLIC,STATE OF NEW YORK (Where the applicant is not the o ner) Registration No.01 SE6012697 Qualified in Sufi'Ilk Cou ty [[33 iVly Commission Expirescz I, Co 4-+ CLO-Y K residing at�I 'R I y aL Ga!S 0rl,10 N )1 4444 do hereby authorize L.oYYcu��l�� n �/g7lc.� to apply on my be f to the T wn of outhold Building Department for approval as described herein. Owner's Signature Date -�'+- ci�rk DEBRA A SEPULYEDA Sc O NOTARY PUBLIC,STATE OF NEW PORK .. Print Owner's Name Registration No.OISE6012697 Qualified in S aco My Commission Expires gufEO(�► Al n BUILDING i$i 0E'ARTMENT- Electrical Inspector c Y 1 4 2024 }TOWN OF SOUTHOLD o i Town Hall Annex - 54375 Main Road - PO Box 1179 o -Southold, New York 11971-0959 4 O� Telephone (631) 765-1802 - FAX (631) 765-9502 Ol '�' �� rogerr(cDsoutholdtownny.gov — seanda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5 13 02 Company Name: 6 I M cA4 Ene r L-L,cj Electrician's Name:-Joi-rrrv(_, M )^y n1 eK License No.: (erg _ ��t Elec. email: Per-m o+5 ��,� �Sb C,)# Elec. Phone No: �a t.7 ;-y��,3 [9I request an email copy of Certificate of Compliance Elec. Address.: -7 4-7 0 �� �„ 0,VC., fil °+�cV, PV V, I JOB SITE INFORMATION (All Information Required) Name: ' C-o+E ClaC Address: q-S Kt-y-W;Y1 11 Cross Street: m 'n R Phone No.: (0 3 1 � °$$ . D L' Bldg.Permit #: email: ;�g Tax Map District: 1000 Section: OS 5, Block: O 3 , 0 b Lot: 01 q, 0 b BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print,Clearly): .Sr,s-�a-t► -F 1 us 1-3 �o �_ rn o�.�.n-�-cam. �o l a.►— P �S S�ih� .:�. y Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ® NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ® NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service[:]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 M H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 122C6 I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 0 � AAAAAA 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 0 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTTf UCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07/13/2023 TO 07/13/2024 7/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION. LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY.INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/NVWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION ANDIOR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND t/ DIRECTOR,INSURANCE FUND UNDERWRITING NERA W 1 workers'STATE I Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1,To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that caffieli 1a.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1 c. 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier i (Entity Being Listed as the Certificate Holder) I 5helterPoint Life Insurance Company TOWN OF SOUTHOtD 54375 MAIN ROAD '3b.Policy Number of Entity Listed in Box-1a" SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides the following benefits: ® A Both disability and paid family leave benefits. B.Disability benefits only. C_Paid family leave benefits only. 5. Policy covers: ® A All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or rwensed agent of the insurance carrier referenced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By (Signature of insurance carrier's authorized representative er NYS licensed Insurance Agent of that insurance carrier) Telephone Number 51&829-8100 Name and Tine Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If sox 46,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Soard Employee,' Telephone Number Name and Title I i Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Fcrm 06-120,1.Insurance brokers are NOT authorized to issue this form. \ I i DB-120.1 (12-21) 11Jill,����i�raii��riiii�iiiiiuiiiiilfl CERTIFICATE OF LIABILITY INSURANCE DATE IM 7I�,D/io 2'/y2y(, THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSUREli AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(W)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A Statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER zli NAME: ROBERT S.FEDE INSURANCE AGENCY PHONE - FAX - - 23 GREEN STREET,SUITE 102 MIC.N ExI, WC No' E-LHUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE wsu AFFORDWG COVERAGE NAIL It INSURER A,ATLANTIC CASUALTY INS.CO. 524210 INSURED :STATEASURANCE FUND 523930 SUFMR N Element Energy LLC B suRER c- SHELTER POINT PUINT —UT43r— DBA ELEMENT ENERGY SYSTEMS INSURER D.GENERAL STAR WANAGEMENT . 7470 SOUND AVENUE BNSURERE: MATTITUCK,NY 11952 RNSIIRER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REOUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, WSR I TYPE OF INSURANCE POLICY EFF POLICY UP LTR POLICY NUMBER /DD MM1ODrfYYY1 LIMITS A COMMERCIAL GENERAL LIABILITY X X L1450036873 7/14/2023' 7/14,2024 NCH OCCURRENCE $ 3,��,0�1} CLAIM$-1IAOE �OCCUR PREMISES 4E.2acnrrrwoe S 100,000 IMA3892?3B MED EXP(A are person) S 5000 X Contractual Lia 7/19/2022 7/19/2024 PERSONAL 1101 11JURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 3 3,000,000 POLICY a ECT LOC PRODUCTS-COMWOPAGG t 3000000 OTHER: 3 AUTOMOBILE LIABILITY COMMINED SINGLE LIMIT : ANY AUTO BODILY INJURY(Per person) s OWNED SCHEDULED BODILY INJURY{Per ealderrt) >< AUrOSONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per..k s UMBRELLALUU9 OCCUR 'EACt1OCCURRENCE S EXCESS LWIf CLAIMS-MADE AGGREGATEH $ DED I I RETENIICN s $ WORKERS COMPENSATION 124494445 TART ER s AND EMPLOYER LIABILITY YIN 7/13/2023 7/13/2024 ANY PROPRIETORIPARTNERIEXECUTME EL EACH ACCIDENT $ '1 000 0m AE B OFFICERAMSER EXCLUDED? N I A (Mandatory in NNi EL DISEASE-EA EMPLOYEE 3 If yes,desube under DESCRIPTION OF OPERATIONS beiWv EL DISEASE-POLICY LIMIT i NY State DBL DSL567527 1101120M 1213112024 Statutory DESCRIPTION OF OPERATIONS/LOCATOR[VEHICLES IACDRD 101,AddXHmal Remarks SadadWe,may In attaeRad I emm spaea Is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certlificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHO_R7IM REPRESENTATIVE efi oC 1988-2015 ACORD CORPORATION. All rights reserved. er-nDn 7t 11AIArn-tk Tr.e Amon APPROVED AS.NOTED OCCUPANCY OR DATE" ' ' •a A 50 USE IS UNLAWFUL FEE BY: WITHOUT CERTIFICATE NOTIFY BUILDING TO 4PM FOR �� � �� � 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. COMPLY WITH ALL CODES OF ALL CONSTRUCTION SHALL MEET THE NEW YORK S ATE&TOWN ODES REQUIREMENTS OF THE CODES OF NEW AS REQUIR YORK STATE. NOT RESPONSIBLE FOR AND CONDITIONS OF DESIGN OR CONSTRUCTON ERRORS SOUMOLD TOWN ZBA SOUTIM TOWN PLANNING BOARD SOUIHOLDTOWN TRUSTEES N,Y.S.DEC SOUMOLD HPC SCHD RETAIN STORM WATER RUNOFF: PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Page 1 of 2 05/08/2024 Current Renewables Element Energy LLC 4b Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Scott Clark Residence Project Address: 595 Kerwin Boulevard, Greenport, NY, 11944 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report :-`for details regarding calculations performed and limits of scope of work and liability. The p design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/3012025 OF NEW 1, Current Renewables Engineering Inc. Professional Engineer Ckz info@currentrenewableseng.com y CFO 106793 � F Nam Signed on:05/08/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com L Page 2of2 Summaries: Check 1: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 16 degrees and has a max beam span of 15.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com ROOF MOUNT SOLAR PERMIT PACKAGE SCOTT CLARK Q . 6.800 KW DC GRID TIED PHOTOVOLTAIC SYSTEM MAY 1 4 202 595 KERWI N BLVD, GREEN PORT, NY 11944 4 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES: THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC REPRODUCTION IN ANY FORM IS 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY EXPRESSLY FORBIDDEN WITHOUT PRIOR POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION WRITTEN APPROVAL FROM CURRENT s 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 2020 NEW YORK STATE BUILDING CODE RENEWABLES ENGINEERING INC. 2020 NEW YORK STATE RESIDENTIAL CODE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 2020 NEW YORK STATE MECHANICAL CODE 2017 NATIONAL ELECTRICAL CODE(NEC) UNDERSIGNED Current •' 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 3IenewabiE 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT • T . SUCH AS GeoCel 2300 CLEAR SEALANT Engineering 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED CURRENT RENEWABLES 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, ENGINEERING INC. MECHANICAL,OR BUILDING ROOF VENTS 1760 CHICAGO AVE SLATE rr ` AHJ:Village of Greenport 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS J-13,RIVERSIDE CA 92507 (�+q� THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PHONE:(951}405-1733 LEGEND 10 EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED WWw.CRENG CO CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S CONTRACTOR INFO INSTALLATION INSTRUCTIONS" 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA uM UTILITY METER PM PRODUCTION METER REGULATIONS r, 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" Ann& .ir�7L - MSP MAIN SERVICE PANEL INV INVERTER 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. -•-- 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY BUILDING INFORMATION COMBINER SUB GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35 C SYS C SUB PANEL 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741, C MODULE BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE ELEMENT ENERGY LLC. 1 STORY HOUSE SINGLE FAMILY RESIDENCE NEC,THE INSTALLATION STAN DARDS/MAN U FACTURE R'S RECOMMENDATIONS AND IF 7470 SOUND AVENUE,MATTITUCK, ROOF OBSTRUCTIONS REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. NEW YORK,11952 KIQ IQ CONTROLLER 2 18 CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" PH:(631)779 7993 CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U i' 36"ACCESS PATHWAYS ABOVE ROOF SURFACE. services@e2sys.com BATTERY 19, IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE Licence-ME-52689 APN : �' 18"ACCESS PATHWAYS RATED FOR EXPOSURE,TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN (MASTER ELECTRICIAN) QH Q.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)1013 OR 12/3 CONDUCTORS THROUGH Licence-HI-67461 1000053000300010000 ROOF ACCESS POINT OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT (SUFFOLK HOME IMPROVEMENT) RAIL AC ESS DISCONNECT 20, MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, SCOTT CLARK SHEET INDEX STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO RAFTER Lc LOAD CENTER THE PURPOSE INTENDED. 595 KERWIN BLVD, ❑ ATTACHMENT GREENPORT,NY 11944 PV-1.0 COVER PAGE = SEPTIC TANK PVSUMMARY PV-2.0 SITE PLAN _ _ MBE MAIN BREAKER LOT SIZE :-0.83 Acres SYSTEM SIZE ENCLOSURE � LEACH LINES sTc 425 x 16 = soo PV-2.1 ROOF PLAN Ts AUTOMATIC TRANSFER PROPANE TANK SYSTEM SIZE s12. 3 X 16 = .370 PV-3.0 STRUCTURAL SWITCH (KWAC) >zo �240 40 WELL 16 DULS 11NKO SOLAR PV-4.0 ELECTRICAL 3LD OP PERMANENT ANCHOR WIND SPEED 128 _ OROENv QrY 1s xn4azsN-saHLa-s O M POWER LINES SNOW LOAD 25 MICRO ENPHASE IQ8MC-72-M-US PV-4.1 ELECTRICAL SLD O EW T TEMPORARY ANCHOR NO LADDER ACCESS EXPOSURE CATEGORY C �0F N INVERTER`P� ONG ISLAND POWER Al PV-4.2 ELECTRICAL PHOTOS 0 (STEEP GRADE R� 4• UTILITYILIPAI INSTALLER LADDER OR GROUND LEVEL � (q�� PV-5.0 BOM OBSTRUCTIONS PV-6.0 SIGNAGE&PLACARD STUB-OUT O GAS SHUT ) `, Rey ° Date GAs OFF r PV-7.0 SPECS+ ® 1 11 A INITIAL DESIGN 582024 SKYLIGHT Hzo WATER SHUT OFF 2 ;a J' 106793 PROJECT# 8858 RESTRICTED ACCESS O7 SERVICE DROP op�4FESS10NP� DATE DRAWN 5/812024 CONDUIT AC DISCONNECT DRAWN BY ER JUNCTION BOX Exp:9/30/2025 SHEET# PV-10 STAMPED 05/08/2024 TITLE COVER PAGE R324.6.1 PATHWAYS: WIND SPEED : 128 NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND SEPARATE ROOF PLANES, SNOW LOAD 25 FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. EXPOSURE CATEGORY C AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR ^� ' UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. 1 FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM ��� i MSP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE .�� 1 C❑ COMBINER OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS � MODULE WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR I MECHANICAL EQUIPMENT. ROOF OBSTRUCTIONS R324.6.2 SETBACK AT RIDGE: i ® 36"ACCESS PATHWAYS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN 1 ® 18'ACCESS PATHWAYS THESE DRAWINGS ARE SUBJECT TO AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A 1 COPYRIGHT PROTECTION BY US LAW. HORIZONTAL RIDGE. PROPERTY LINE 1 ROOF ACCESS POINT REPRODUCTION IN ANY FORM IS FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 , i EXPRESSLY FORBIDDEN WITHOUT PRIOR PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A ' WRITTEN APPROVAL FROM CURRENT 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A I 1 RENEWABLES ENGINEERING INC. HORIZONTAL RIDGE. ' R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS I I Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 1 I t�O NEW y Renewab�es AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE I i �` A• Z4 O� Engineering PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. NOTES: I * titi * CURRENT RENEWABLES r ENGINEERING INC. 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED 1760 CHICAGO AVE SUITE ON ACTUAL SITE CONDITION AND i , 1.1 MEASUREMENTS. ' r PHONE: E:(951IDECA92507 � n (V PHONE:(951)405-1733 www.CRE 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS I I 2 793 COONN 10679 �� TRACTOR INFO INCORPORATED INTO THE 2017 NEC AND UL , STANDARD 1741. I 239'-6" SSI�NP� 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. I I Exp:9/30/2025 a ® rM STAMPED 05/OS/2024 Cz SYS 1 ' ILA 1 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTRUCK, N I I NEW YORK,11952 PH:(631)7717993 i I services@e2sys.com Licence-ME-52689 i (MASTER ELECTRICIAN) 1 Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) j MSP UM SCOTTCLARK I i 595 KERWIN BLVD, I , GREENPORT,NY 11944 FENCE i I C PV SUMMARY / SYSTEM SIZE 1:1(CWDO) STC 425 X 16 = .800 FENCE/GATE SHED 1 PTC 398.1 X 16 = .37D 1 ' ' I SYSTEM SIZE 5.120 @240 I (KWAC) 11NKO SOLAR ENLARGED VIEW MODULES 16 1KM425N-54HL4-B ROOF ACCESS POINT MICRO INV.QTY : 16 • ' '1 1 1 INVERTER ENPHASE IQ8MC-72-M-US i 551-91 2 LONG ISLAND POWER AUTHORITY .►. I UTILITY (LIPA) ROOF OBSTRUCTION I I ROOF LINE Re Des pbon ow i ROOF ACCESS POINT A I INITIAL DESIGN SIEM24 1 1 j 1 1 R I L5MM24 mm 0 351-211 I E.R SITP �1 -0' PROPERTY LINE PV-2A 1 SCALE: 1/32" = 119'-3" SITE PLAN KERWIN BLVD ARRAY AREA LEGEND ARRAY ROOF ROOF TOTAL ROOF AZIMUTH #OF AREA AREA AREA AREA STRUCTURAL NOTES : uM UTILITY METER MODULES (Sq.Ft.) (Sq.Ft.) COVERED COVERED BY 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF ARRAY(%) ARRAY(%) FRAMING SUPPORTING THE PROPOSED PV INSTALLATION ONLY. MSP MAIN SERVICE PANEL #1 124° 16 336.32 1162 28.94 28.94 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. COMBINER 3. PV MODULES. RACKING, AND ATTACHMENT COMPONENTS MUST FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. MODULE 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ROOF OBSTRUCTIONS ADDITIONAL INFORMATION. 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR INSTALLER SHALL VERIFY THE ROOF ® 36"ACCESS PATHWAYS FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY ® 18-ACCESS PATHWAYS INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 2x8 RAFTERS @ 16" OC THESE DRAWINGS ARE SUBJECT TO SPACING WITH MAX UNSUPPORTED SPAN EOUAL OR LESS THAN 15 FT. RAIL COPYRIGHT PROTECTION BY US LAW. RAFTER REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR ATTACHMENT WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering lc CURRENT RENEWABLES p��pF NEw yo ENGINEERING INC. 1760 CHICAGO AVE SUITE r—� O�RT A. �q /P� J-13,RIVERSIDE CA 92507 —J PHONE:(951}405-1733 3, �O. �N of WWWCRENGCO * * CONTRACTORINFO Clf a '6 p'POFESSIONP� EZSYS Exp:9/30/2025 S ELEMENT ENERGY LLC. TAMPED OS/08/2024 7470 SOUND AVENUE,MATTITUCK, UM NEW YORK,11952 PH:(631)779 7993 C services@eZsys.com ` I Licence-ME-52689 (MASTE L cent a ELECTRICIAN) (SUFFOLK HOME IMPROVEMENT) SCOTT CLARK 595 GR ENPORTINY11944 I I I ! I I I I I I I I I I PV SUMMARY I ROOF#1 SYSTEM SIZE STC 425 X 16 = 8,00 (KW DC) ! PTC 398.1 X 16 = .370 - SYSTEM SIZE(KWAC) 5.120 @240 SOLAR MODULES 16 /M4025N-54HL4-B MICRO-INV.QTY 16 MICRO :INVERTER ENPHASE IQSMC-72-M-US (N)16 JINKO SOLAR JKM425N-54HL4-B unuTv ;OP;ISLAND POWER AUTHORITY Rev Description Date A INITIAL DESIGN 5/82024 K E R W I N B LV D PROJECT# 8858 DATE DRAWN 5/8/2024 I- ROOF PLAN DRAWN BY ER 2 SHEET p PV 2 1 TITLE SCALE: 3/16" = 1'-0" ROOF PLAN TABLE 1 TABLE 2 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG s2 IRONRIDGE QUICKMOUNT HALO ULTRA ATTACHMENT O GRIP ROOF 1 160 COMP SHINGLE RAFTER 2X8 16" 64" 24" 0 RAIL IRONRIDGE XR-100 RAIL �A\�O�R`A. (4 ;j!,� r 1 Cl= THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. � REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR v(� 106793 (��\ WRITTEN APPROVAL FROM CURRENT Q tr RENEWABLES ENGINEERING INC. SSIONP� Exp:9/30/2 Current 025 STAMPED 0/ 025 Renewables Engineering RAFTER MOUNT ! CURRENT R LES ENGINEERINGG INC.INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951 Y405-1733 WNW.CRENG.CO CONTRACTORINFO MODULE _ TABLE: PENETRATION S3 GUIDE FOR INSTALL S2 TWO OR MORE ROWS OF PANELS CZSYS I ELEMENT ENERGY LLC. ROOF 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@eZI I I I I I I I I I I I I I Licence-MEs52689 S1 BED . (MASTER ELECTRICIAN) I Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) SCOTT CLARK 595 KERWIN BLVD, NOTE.INSTALL IRONRIDGE HALO ULTRA GREENPORT,NY 11944 GRIP ATTACHMENT"RAFTER CONNECTION'PER MANUFACTURER'S STACKED STAGGERED FULLY STAGGERED PV SUMMARY WRITTEN INSTRUCTIONS(2-#14 X 3"X RD SYSTEM STE SIZE src azs x 1s = .Boo STRUCTURAL WOOD SCREWS TO EXISTING RAFTER) ENLARGED VIEW ONE ROW OF PANELS PTC 398.1 X 16 1+370 SYSTEM SIZE(KWAC) 5.120 @240 MODULES 16 IINKO SOLAR 1KM425N-54HL4-B MICRO-INV.QTY 16 MODULE I I I I I I I I I I I I MICRO ENPHASE IQBMC-72-M-US I I I I I I I I ( I I I INVERTER UTILITY LONG ISLAND POWER AUTHORITY (LIPA) FULLY STAGGERED STACKED/STAGGERED SEE ENLARGED VIEW RN Desmption D. A INITIAL DESIGN 5!&1024 S1 PROJECT# 8058 ROOF DATE DRAWN 5W024 DRAWN BY E.R SHEET# PV-3.0 TITLE ATTACHMENT DETAILS STRUCTURAL BACKFEED BREAKER SIZING ELECTRICAL EQUIPMENT LIST �pF NE(l,Y MAX.CONTINUOUS OUTPUT 1.33A @ 240V �Q'� �MAN/ 0 21.28 1XI 1.25 1 = 26.60AMPS 130A BREAKER-OK S. NO. ITEMS DESCRIPTION QTY. ZOO `"1 9C �r SEE 705.12 OF 2017 NEC JINKO SOLAR D w 200 1XI 1.20 1240 JKM425N-54HL4-B ACCOUNT NO : 9672025750 240 200 j = 140AALLOWABLE BACKFEED Z i099128w 2 MICROINVERTER ENPHASEIQ8MC-72-M-US 16 METER NO: 98413254 N IG c�� C7R1GP� ENPHASE COMBINER BOX AROFESSIONP� 3 COMBINER X2-IQ-AM1-240-4 1 STAMPED 05/08/2024 (E)UTILITY METER TO UTILITY GRID E SUBJECT TO 3 COPYRIGTHESE HT PIROTECNGS RTION BY US LAW. REPRODUCTION IN ANY FORM IS (N) ENPHASE (E)200A RATED • EXPRESSLY FORBIDDEN WITHOUT PRIOR COMBINER BOX MAIN SERVICE PANEL WRITTEN APPROVAL FROM CURRENT 1PH,120/240V 60HZ RENEWABLES ENGINEERING INC. (E)200A/2P MAIN CELL WIRELESS BREAKER Current MODEM COMMS (TOP FED) -i IQ TGA EWAY n 1 � Engineering Z A ;!(N)15A,� CURRENT RENEWABLES (- 1 ENGINEERING INC. TO OTHER�� 1760 CHICAGO AVE SUITE 1 BRANCH OF 8 IN I I LOAD PHONE 95111)-405-1733-13,RIVERSIDE CA �7 PV MODULE I I •� WWw.CRENG Co (N)20A/ I I • �R I I (N)30A 12P PV l •/T� CONTRACTOR INFO I (N)2DA_/1 I I BREAKER • Fl 2 BRANCH OF 8 ------- �J L-------- . PV MODULE N Cc SYS_ B ELEMENT ENERGY LLC- 7470 SOUND AVENUE,MATTITUCK, MODULE JINKO SOLAR NEW PORK,11952 _ MANUFACTURER (E)GROUNDING ELECTRODE i PH:(631)779 7993 CONDUCTOR#6 BARE COPPER services@e2sys.com MODULE MODEL JKM425N-54HL4-B Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 MODULE(W) 425 (SUFFOLK HOME IMPROVEMENT) MODULE PTC(W) 398.1 SCOTT CLARK MODULE Isc(A) 13.58 NOTE: 595 KERWIN BLVD, MODULE Voc(V) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS GREENPORT,NY 11944 MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. MODULE Vmp(V) 32.37 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A SIZE(KWDC) STC 425 x 16 =6800 KWDC) PTC 398.1 1 X 1 16 =6.37C WIRE CALCULATION (KWAC) 5.120 @240 STARTING ADJUSTMENT MAXIMUM JINKO 50LAR STARTING TEMPERATURE MODULES 16 JKM425N-54HL4-B CURRENT : s CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION FACTOR FOR ADJUSTED CURRENT MICRO-INV CITY 1 TAG DESCRIPTION MORE CONDUCTOR APPLIED TO MICRO ENPHASEIQ8MC-72- -us � QTY. SIZE (AWG) SIZE&TYPE AMPACITY RATING (°C) APPLI ED TO M FACTOR INVERTER CONDUCTORS CONDUCTORS AMPACITY CONDUCTORS N ISLANDwERAIfrHORrry 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY UTILITY LIRA) ---. — A 2 12 SKU: Q-12-RAW-300, THHN N/A FREE AIR 30 90° 10.64 0.96 1 28.80 13.30 plJo� Date 1 8 THWN-2 BARE COPPER-(GROUND) RAINITIALev D ESIGN 5W024 3 10 THWN-2 COPPER-(L1,L2) B 3/4" PVC 40 90° 21.28 0.96 1 38.40 26.60 IS 1 8 THWN-2 COPPER- (GROUND) PROJECT sass ATE DRAWN 5/8/2024 RAWN BY ER HEET## PV-4.0 TITLE ELECTRICAL 3LD BACKFEED BREAKER SIZING MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST ��pF NEINyp 21.28 X 6 60AMPS 30A BREAKER-OK 125 = 2 . �P p0E MAN/q S.NO. ITEMS DESCRIPTION QTY. � SEE 705.12 OF 2017 NEC JINKO SOLAR * L S * 200 X 1.20 = 240 1 PV MODULE JKM425N-54HL4-B 16 ACCOUNT NO : 9672025750 - D w 0 W 240 200 = 40A ALLOWABLE BACKFEED � 2 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 16 METER NO: 98413254 �' CTRICI ENPHASE COMBINER BOX AROFESS1pI�p� 3 COMBINER X2-IQ-AM1-240-4 1 STAMPED 05/08/2024 (E)UTILITY METER TO UTILITY GRID NGS ARE SUBJECT TO 3 } COPYRIGHTHESE T PIROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS (N)ENPHASE (E)200A RATED EXPRESSLY FORBIDDEN WITHOUT PRIOR COMBINER BOX MAIN SERVICE PANEL WRITTEN APPROVAL FROM CURRENT 1 PH,120/240V 60HZ RENEWABLES ENGINEERING INC. (E)200A 12P MAIN CELL WIRE LESS BREAKER MODEM COMMS (TOP FED) Current IQ GATEWAY n 1 I — engineering 2 A I(N)15A� • • CURRENT RENEWABLES m " ENGINEERING INC. TO OTHER •�• 1760 CHICAGO AVE SUITE LOAD— --• J-13,RIVERSIDE CA 92507 1 BRANCH OF PV O MODULE N �• PWWW.CRENG C01733 I(N)20 6� /'� (N)30A/2PPV .•/���. CONTRACTOR INFO (N)20A� BREAKER 2 BRANCH OF 8 PV MODULE N CZ SYS� B ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTfTUCK, MODULE JINKO SOLAR MANUFACTURER GROUNDING ELECTRODE _ NEW PORK,1195 (E) PH:(631)779 7993 CONDUCTOR#6 BARE COPPER services@e2sys.com Licence-ME-52689 MODULE MODEL JKM425N-54HL4-B (MASTER ELECTRICIAN) Licence-HI-67461 MODULE(W) 425 (SUFFOLK HOME IMPROVEMENT) MODULE PTC(W) 398.1 SCOTT CLARK MODULE Isc(A) 13.58 NOTE: 595 KERWIN BLVD, MODULE Voc(V) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS GREENPORT,NY 11944 MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH SYSTEMPV SUMMARY MODULE Vmp(V) 32.37 (KWDC) PROPER JUNCTION BOX AT EACH END PER 690.31A SIZESTc 425 x 00 16 = 8KWDC) -- — — -- WIRE CALCULATION SYSTEM SIZE(KWAC) 5.120 @zao STARTING ADJUSTMENT MAXIMUM MODULES 16 JINKO SOLAR STARTING TEMPERATURE JKM425N-54HL4-B CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INv QTY 16 CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION MORE THAN 3 CONDUCTOR APPLIED TO MICRO TAG DESCRIPTION APPLIED TO FACTOR INVERTER ENPHASE IQ8MC-72-M-US QTY. SIZE (AWG) SIZE&TYPE AMPACITY RATING (°C) CONDUCTORS CONDUCTORS AMPACITY CONDUCTORS ONG IS AND PowER AUTHORITY uTlu Y (uPA> 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY SKU: Q-12-RAW-300, THHN A 2 12 N/A FREE AIR 30 90° 10.64 0.96 1 28.80 13.30 Rev Description Date 1 8 THWN-2 BARE COPPER-(GROUND) A INITIAL DESIGN 5/11/2024 3 10 THWN-2 COPPER-(L1,L2) B 3/4" PVC 40 90° 21.28 0.96 1 38.40 26.60 MTITLE 1 g THWN-2 COPPER-(GROUND) 24 1 ELECTRICAL SLD EXISTING SERVICE PANEL PHOTOS ��pF NE�y� �P OOP MA/y�A O11 * � wit m w 099128 ��11? ZN�O Z CTRIr- ARO�Ss�oNP� STAMPED 05/08/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLE$ENGINEERING INC. /10 Current Engineering CURRENT RENEWABLES ���I.' ENGINEERING INC. j 1760 CHICAGO AVE SUITE _ T J-13,RIVERSIDE CA 92507 h PHONE:(951)405-1733 WWW.CRENG.CO . CONTRACTOR INFO r ` MEE Ez SYS! - ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 ♦ (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) r SCOTT CLARK 595 KERWIN BLVD, GREENPORT, NY 11944 PV SUMMARY SYSTEM SIZE STC 425 X 16 = 800 (KWDC) PTC 398.1 X 16 = .370 STEM SIZE(—AC) 5.120 @240 MODULES 16 11NK0 SOLAR JKM425N-54HL4-B MICRO-INV.OTY 16 - MICRO : ENPHASE"._C-72-M-US INVERTER UTILITY LIPA) Rev De cnPtlon Date A INITIAL DESIGN 5/82024 PROJECT# BB58 -` DATE DRAWN 5WO24 = DRAWN BY E.R SHEET# PV-42 TITLE ELECTRICAL PHOTOS MATERIAL LIST OF NEINy � p �P�oQrG MANi,4 * 0 ,t ELECTRICAL EQUIPMENTS 7 Qn• PART TYPE PART NUMBER DESCRIPTION m 0991�28 z 16 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B oA` RIB 16 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US ROFESSI 1 COMBINER X-IQ-AM 1-240-4/4C X-1Q-AM 1-240-4/4C STAMPED 05/08/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Engineerinc CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)405-1733 WWW.CRENG.CO CONTRACTOR INFO Q BREAKER/ FUSES DESCRIPTION n. Wl PART TYPE PART NUMBER 1 BREAKER 30A 2-POLE BREAKER(S) GENERAL 30A 2-POLE BREAKER(S) CZSYS_- 2 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) SCOTT CLARK RACKING 595 KERWIN BLVD, Qn. PART TYPE PART NUMBER DESCRIPTION GREENPORT,NY 11944 12 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK PV SUMMARY SYSTEM SIZE STC 425 X 16 = 800 8 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 `""°°' E PTC 398.1 X 16 = .370 (KW 28 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK SYSTEM SZE 5.120 @,240 8 CLAMPS & GROUNDING UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK MODULES 16 JINKO SOLAR JKM425N-54HL4-B MICRO-INV.QTY : 16 2 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE MICRO ENPHASE IQ8MC-72-M-US INVERTER 28 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK UTILITY 'OPA'IS AND PowER AUTHORITY Rev Descnphon Date A INITIAL DESIGN 5,8/2024 PROJECTtt 8858 DATE DRAWN 5/8/2024 DRAWN BY ER SHEET# PV-5.0 TITLE BOM CAUTION ��oF M NEl1,y Q� � A 0,p MULTIPLE SOURCE OF POWER /�/��i � G * , D W m w MPHOTOVOLTAIC 2N��,p_ � crR1GP�'SS,oNP� STAMPED 05/01✓2024 690.12 CID Z THESE DRAWINGS ARE SUBJECT TO SOLAR PV SYSTEM EQUIPPED COPYRIGHT PROTECTION BY US LAW. RAPID IS SHUTDOWN ]G EXPRESSLY FORBIDDEN WILLJ REPRODUCTION IN ANY THOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. TURN RAPID PDISCONNECT1� Curren SHUTDOWN SWITCH TO RATED OUTPUT THE"OFF" POSITION TO AC AC NORMALOPERATING VOLTAGEVOLTS Engineering SHUT DOWN PV SYSTEM 690.14,690.15,690.54CURRENT AND REDUCE SHOCK ENG NEER NG INC. 1760 CHICAGO AVE SUITE HAZARD IN THE ARRAY PM PV ARRAY J-13,RIVERSIDE CA 92507 DUAL POWER • . • . WWW.CPHONE: ENG.51 05-1733 690.56(C)(1)(B) WWW.CRENG.CO SECOND • • •-VOLTAIC SYSTEM CONTRACTORINFO RATED • OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE -240 VOLTS a ® 11191 _ _ COMBINER MAIN SERVICE PANEL •• 690.5a C2 SYSgu OPTIONAL SOLAR LOAD CENTER UELEMENT ENERGY LLC. TILITY METER- ARRAY 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL Licence-ME-52689 1117) ER ELECTRICIAN) jlu PANEL IS AC DISCONNECT PER NEC690.17 (MLicence H 674611 (SUFFOLK HOME IMPROVEMENT) 11WARNING66 SCOTT CLARK INVERTER OUTPUT CONNECTION595 KERWIN BLVD, • • RELOCATE • • GREENPORT, NY 11944 NEC 690.31(13)(3)&(4),CRC R324.7 PV SUMMARY • DEVICE SYSTEM SIZE • (KWDC) STC 425 X 16 =6.600 (UNLESS BUSBAR IS FULLY RATED) PTG 39e.1 1 X 1 16 = .370 705.12(D)(2) PHOTOVOLTAIC POWER SOURCE TE (KWAC) 5.120 @240 11NKD SOLAR EVERY 10'ON CONDUIT AND ENCLOSURES MODULES 6 1KM425N-54HL4-B MICRO-INV-QTY 16 MICRO EN PHASE IQ8MC-72-M-US NOTES. INVERTER UTILITY N I LAN POWER AUTHORITY LIPA) 1. nec ARTICLES 690 AND 705 AND nec SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Dewrioem Date A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A INITIAL DESIGN 518r2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE PROJECT p BBSB WORK. C. AERIAL FONT. DATE DRAWN 518rz024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN D1L1WN BY E.R THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET fI PV-6.0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. Engineering Drawings www.jinkosolar.com J%nK0 Bui,dinc your Trust m Soler Cu rtl Vol,oge L Pa vo°oge T•^ ,Iw Dep•d•�<.°f Tiger Neo N-type HISW1 cvoc Pmaa 54HL4-B _ THESE DRAWINGS ARE SUBJECT TO F y ,m COPYRIGHT PROTECTION BY US LAW. 4 ���� — I • -30 REPRODUCTION IN ANY FORM IS „IL � 6 .,.o� � r° EXPRESSLY FORBIDDEN WITHOUT PRIOR T _ • :m ro WRITTEN APPROVAL FROM CURRENT _� RENEWABLES ENGINEERING INC. ALL-BLACK MODULE Currer- N-Type �. ,„. ,ar Positive power tolerance of 0-+3 Englnee'In 7o CURRENT RENEWABLES IEC61215(2016).IEC61730120161 umpnam.r. ENGINEERING INC. _______ - 1760 CHICAGO AVE SUITE 1509001:2015:Quality Management System T- �''••`�"'^ Mechanical Characteristics J-13,RIVERSIDE CA 92507 ISO 14001:2015:Environment Management System i 1 3W •I 1p�^s�"^� Ceb. ?ype N type Morro-crystoline PHONE.(951)-a05-1733 I WWW.CRENG.CO ISO45001:2018 L CONTRACTOR INFO Occupational health and safety management systems •* Dimensions 1722-1134-30mm(67.79.44.65.1.18 inch) Key FeaturesPackaging • • Front � 3.2mmsion.Low Iron, mp Coating. a High Transmission.Low kon,Tempered Glass (Twc Paled=One Stack I Junction Box tP68 yo,,�d Cz SYS� FW1SMBB Technology Hot 2.0 Technology or Better light trapping and current collection to improve HOT The N-type module with Hot Z.0 technology has better ELEMENT ENERGY LLC. module power output and reliability. 2.0 reliability and lower UDAETID. 7470 SOUND AVENUE,MATTTTUCK, NEW YORK,11952 SPECIFICATIONSPH:(631)779 7993 services@e2sys.com Module Type JKM425N-54HL4-8 Licence-ME-52689 (MASTER ELECTRICIAN) PID Resistance ++++ Enhanced Mechanical Load 51c . Licence-HI-67461 kH Excellent Anti-ID performance guarantee via a Certified to withstand:wind load(2400 Pascal)and snow Maximum Po—!Pmpzl e25wc 370wp (SUFFOLK HOME IMPROVEMENT) optimized mass-production process and materials s.�.., load(5400 Pascal). a control. �•LY4ailo•elWrtpl 3237V 3MI9'V -----__ _-— ` SCOTT CLARK Maximum POwer Current(imp) 13.13A 10.60A 595 KERWIN BLVD, 4"' - GREENPORT,NY 11944 Short-circuit Current(Isc:) 13.58A 13. ,bk ®� Durability Against Extreme Environmental ! P �Y STC.IxI - - -- -- SYSTEM SIZE :P STC SUMMARY25 X 16 = .am ® CE - 0 Pps i�ou�iTY -Operating Temne,ohnel°C) -40'C-+85-C (KWDC) Conditions l�tiff' PTC 398.1 X 16 High salt mist and ammonia resistance. Maximum series fuse rati,rg 21,1 SYSTEM SIZE S.12f1 �� (KWAC) MODULES 16 IIKM4INKO SOLAR KM425N-54HL4-B 'e"tPerat�re MICRO-INV.CITY 16 LINEARPERFORMANCE WARRANTY Temperatuo aaelKclenth;of voc _0.25V__C MICRO INVERTER ENPHASEIQ8MC-72-M11S 'e'loomture coefficient of Isc ONG ISLAND POWER AUTHORITY UTILITY LIPA) 100% WORllsr o14 teirtperature INOCT) 45d.2°C 99% 25 Year Product Warranty $TC: :Irradiance 1 OOOW Cell Temperature 25°C <1 AM=1.5 Rev Desc ptbn Date A INITIAL DESIGN 502024 30 Year Linear Power Warranty NOCT: *Irradiance sooty/m Ambient Temperature 20°C AM=1.5 Wind Speed Im/s D W w 87.4% PROJECT# 8858 `o 07 u am,z y� 0.40%Annual Degradation Over 30 years QJ2023 Jinko Solar Co.,Ltd.All rights reserved. DATE DRAWN 5f6J2024 m Specifications included in this dotasheet are subject to change without notice. JKM405-425N-54HL4-B-F3C2-EN DRAWN BY ER Datasheei valid in Europe only. SHEET a PV-7 0 TITLE MODULE SPEC ENPHASE IQ8MC Microinverter INPUT DATA CDC) UNITS 108NIC-72-101-US Commonly used module pairings v/ 260 460 wModule compatibility To meet compatibility,PV modules must be within the following max.input DC voltage and max.module Ir Module compatibility can be checked at httpsY/enphase.com/installers/microinvenws/calculator. THESE DRAWINGS ARE SUBJECT TO MPPT voltage range v 25-45 COPYRIGHT PROTECTION BY US LAW. REPRODUCTIONFORM Operating range v 18-58 EXPRESS Y FORBIDDEN WITHOUTT PRIOR Min./Max,start voltage v 22758 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.Input DC voltage v 80 Max.continuous operating DC current A 14 Current j Max.input DC short-circuit current A 25 " v Max.module ly A 20 Engineering Over voltage class DC port 8 xt4':" ' OCporaceecurre Ina 0 ---- -----_---- ENGR NEERIRENIEWABLES port current PV array configuration Ungrounded ar no additional DC side Protection requires max 20 A per branch cYdlt 17 3.CIVERSI AVE SUITE g g ray, prof rogtied;AC side protection r J-13,RIVERSIDE CA 92507 PHONE:(951}405-1733 W W W.CRENG.CO Peak output power VA 330 315 CONTRACTOR INFO Max.continuous output power VA 320 310 Q 8 M C M i c ro i n ve rt e r Nominal grid voltage(L-L) v _— 240,split-phase(L-L7,�' __ 208,single-phase(L-L).120' Easy to install Min./Max.grid voltage- V 211-264 183-229 Our newest IQ8 Series Microinverters are the irldustry's first micrt3grid-forming',software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 C SYS defined microinverters with split-phase power conversion capability to convert DC power to rind play connectorsNomal frequency rd 60 in AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range Rt 47-68 application-specific integrated circuit(ASIC).which enables the microinverter to operate in between components ELEMENT ENERGY LLC. grid-tied or off-grid modes.This chip built in advanced 55-ism technology with high-speed • Faster installation with simple two-wire AC short circuit fault current over three A,� 2.70 7470 SOUND AVENUE,MATTITUCK, digital logic and has superfast response times to changing bads and grid events.alleviating cycles constraints on battery sizing for home energy systems. cabling NEW Y 11952 Max.units per 2OA(L-U branch circuit' 12 10 PH:(631)1)77 7797993 serHigh productivity and reliability Total harmonic distortion Licence-ME- 2689 Licence-ME-52689 Produces power even when the grid is (MASTER ELECTRICIAN) down' Overvoltage class AC port III Licence-HI-67461 More than one million cumulative hours AC port backfeed current mA 18 (SUFFOLK HOME IMPROVEMENT) of testing Power factor setting 1•0 _ _ _ SCOTT CLARK Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class If double-insulated enclosure Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging I08 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered 595 KERW I N BLVD, the IQ Battery,IQ Gateway.and the million cumulative hours of power-on PV modules Peak efficiency 97A 972 GREEN PORT,NY 11944 Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency . 97.0 9" software. limited warranty of up to 25 years. Microgrid-forming Pv u Nighttime power consumption mw 33 25 SYSTEM SIZE MMARY • Complies with the latest advanced grid MECHANICAL DATA UNITS (KWDC) : STC 425 X 16 =6800 support Case Ambient temperature range ^40Y'to 85°C(-40°F to 149'F) PTC 398.1 X 16 = 370 • Remote automatic updates for the SYSTEM SIZE 5.120 @240 latest ridr requirements Relative humidity range 4%to 100%(condensing) (KWAC) 0 JINKO SOLAR Configurable to support a wide range DC connector type StSubli MC4 MODULES 16 J6 1 KM42SN-54HL4-B of grid profiles Dimensions(H•W.D);Weight 212 mm(8.3")•175 mm(6.9")°30.2 mm(1.2");1.1 kg(2.43 Ids) MICRO-INV. 7Y t Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed MICRO : ENPHASE I08MC-72-M-us to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans INVERTER 11 integrated MC4 connectors. conforms with various r 1547:2018(UL 1741-SB) UTILITY LONG ISLAND POWER AUTHORITY e9 regulations when Approved for wet locations;Pollution degree Yes;PD3 LIPA) installed according to the manufacturer's instructions. Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure NOTE: -__.— --------_---- - .-_ ---- 108 MicrPmerters cannot be mixed together with Environ.category;UV exposure rating NEMA Type 8;outdoor Rev Description Data previous genentlons of Enphaae mdromverters (107 Series.106 Series.etc.)in the same system. A INITIAL DESIGN 5/8/2024 'Meets UL 1747 Doty when installed with 109ysUm Controller 2 and 3. IQ Gateway is required to change the default grid CA Rule 21(UL 1741-SA),UL 62109-1.IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 profile at the time of installation to meet the local Certifications This product is UL Listed as Pv rapid shutdown equipment and conforms with NEC 2014.NEC 2017,NEC 2020,and NEC 2023 section 690.12 and Authority Hawng Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. se PROJECT# O 2023 Erptlase Energy.All rights reserved.Enphasa.the a and CC logos.10.and certain other marks listed at (1)No enforced DC/AC ratio. 8858 httosJ/erwhaw.wm/trademark-use -yMd_rws an tndamarks of Enphase,Energy.Inc.in the US and other countries. (2)Nominal voltage range can be extended beyond nominal It mWired by the Utility. DATE DRAWN 5/8t2024 Data subject to diaries IQBMC MC4-DSH-0004e-10-EN-U8-2023-1D-1e (3)Limits may vary Refer to localnqulremants to tlefina them ,or mlc 6...rters par bra our branch;,y area. IQ8MC-MC4-DSH-00040-�.O-EN-US-202S-10-1a DRAWN BY ER SHEET# PV-7.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER IQ Combiner 4 IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20 t 0.5%) X-IQ-AMI 240-4 and consumption monitoring it 2.5%)Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to X2-IQ-AM 1-240-4(IEEE 1547:2018) deflect heat ----- IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20 t 0 5%) THESE DRAWINGS ARE SUBJECT TO X-IQ-AM1-240-4C and consumption monitoring It 2.5%).Includes Mobile Connect cellular modem(CELLMODEM-Mt-06-SP-05),a plug-and-play COPYRIGHT PROTECTION BY US LAW. IQ Combiner 4/4C The IQ Combiner 4/4C with IQ Gateway and industrial-grade cell modem for systems up to 60 microinverters(Available in the US Canada,Mexico Puerto Rico,and the REPRODUCTION IN ANY FORM IS X2-IQ-AMt-240-4C(IEEE 1547:2018) US Virgin Islands where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the EXPRESSLY FORBIDDEN WITHOUT PRIOR integrated LTE-M1 cell modem(included IQ Battery and IQ System Co—'re,andtodenect heat WRITTEN APPROVAL FROM CURRENT ACCESSORIES AND REPLACEMENT PARTS (not included,order Separately) RENEWABLES ENGINEERING INC only with IQ Combiner 4C)consolidates Supported microinverters 106,IQ7,and I08.(Do not mix 106/7 Microinverters with I08) Interconnection equipment into a single �, Current Communications Kit COMMS-CELLMODEM-M1-06 Includes COMMS-KIT-01 and CELL MODEM-M1-06-SP-05 with 5-year Sprint data plan enclosure It streamlines IQ Microinverters and w►abieS CELLMODEM-M1-06-SP-05 4G based LTE-Mt cellular modem with 5-year Sprint data plan- Storage Installations by providing a Consistent, CELLMODEM-M 1-06-AT-05 4G based LTE-M1 cellular modem wrth 5 year AT&T data plan Engineering Circuit Breakers Supports Eaton BR210,BR215.BR220,BR230,BR240,BR250.and BR260 circuit breakers. pre-wired solution for residential applications. BRK-1OA-2-240V Circuit breaker,2 pole,10A Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 CURRENT RENEWABLES BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 ENGINEERING INC. ri It offers up to four 2-pole input circuits and Circuit breaker,2 le,15A,Eaton BR2158 with hold down kit support 1760 CHICAGO AVE SUITE BRK-15A-2P-240V-B J-13,RIVERSIDE CA 92507 Eaton BR Series buSbar assembly. BRK-20A-2P-24OV-B Circuit breaker.2pole,20A,Eaton BR2208 with hold down kit support PHONE(951)405 T733 XA-SOLARSHIELD-ES Replacement solar shield to,IQ Combiner 4'4C WWW.CRENG.GO r• XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) CONTRACTOR INFO X-IQ-NA-HD 125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT A pair of 200A split core current transformers - Smart (CT-200-SPLIT/CT-200-CLAMP) ELECTRICAL SPECIFICATIONS a Includes IQ Gateway for communication and control pawn — Continuous duty I Includes Mobile Connect cellular modem g _ (CELLMODEM-M1-06 SP-OS),included only with System voltage 120/240VAC,60 Hz C�SYS IQ Combiner 4C Eaton BR series busbar rating 125A Max continuous curren+rating 65A ELEMENT ENERGY LLC. Includes solar shield to match Enphase IQ Battery 7470 SOUND AVENUE,MATTTTUCK, aesthetics and deflect heat Max corninuous current rating(input from PV/storage) 64A NEW YORK,11952 1, Supports Wt-Fi,Ethernet,or cellular connectivity Max fuse/circuit rating(output) 90A PH:(631)779 7993 services@e2sys.com Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton OR series Distributed Generation(DG)breakers only(not included) Licence-ME-52689 Provides production metering and consumption Max total branch c cuwt breaker rating(input) 80A of distributed generaton'95A w,th IG Gateway breaker included (MASTER ELECTRICIAN) monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Licence-HI-67461 Production metering CT 200A solid core pre installed and wired to IQ Gateway (SUFFOLK HOME IMPROVEMENT) Simple MECHANICAL DATA SCOTT CLARK X-10-AM1-240-4C Mounts on single stud with centered brackets Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14 75 in x 19.5 in x 6.63 in)Height Is 53.5 cm(21.06 in)with mounting brackets 595 KERW I N BLVD, X2-IQ-AM1-240-4C(IEEE 1547:2018) Supports bottom,back and side conduit entry Weight 75 kg(16 5 ins) GREENPORT,NY 11944 Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -40°C to+46-C(-40-F to 115-F) PV SUMMARY plug-in breakers(not included) Cooling Natural convection,plus heat shield SYSTEM SIZE (KWDC) STC 425 X 16 =600.8 BOA total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified.NEMA type 3R,polycarbonate construction PTC 396.1 1 X 1 16 =6.370 { Wire sizes 20A to 50A breaker inputs 14 to 4 AWG copper conductors SYSTEM SIZE • 60A breaker branch input.4 to 1/0 AWG copper conductors (KWAC) 5.120 Q240 Reliable Main lug combined output.10 to 2/0 AWG copper conductors Neutral and ground 14 to 110 copper conductors MODULES 16 i1NKO SOLAR 1KM425N-54HL4-B I Durable NRTL-certified NEMA type 3R enclosure Always follow local code requirements for conductor sizing. MICRO-INV.CITY 16 • Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) MICRO ENPHASE IQ8Mca2-M-US t 1 Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS INVERTER LONG ISLAND POWER AUTHORITY ncluded for both the IQ Combiner SKU's - -- --------- — - -- --— "-'- UTILITY Integrated Wi-Fi IEEE 802 11 b1g/n LIPA) X-IQ-AM1-240-4 UL listed cehula CELL MODEM-Mt-06-SP-OS,CELLMODEM-Mt-06-AT-05(413 based LTE-M1 cellular modem).Note that an Mobile Connect X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with cellular modem is required for all Enphase Energy System installations X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 1547 2018 "UL 1741-SB,3 Ed p ( ) Ethernet Optional,IEEE 802 3.CatSE(or Cat6)UTP Ethernet cable(not included) Rev Description Date COMPLIANCE A INITIAL DESIGN 518/2024 _ Compliance,IQ Combiner CA Rule 21(UL 1741-SA) IEEE 15472018-UL 1741-SB,3"Ed (X2-10-AM1-240-4 and X2-I0-AMt-2404C) CAN/CSA C22.2 No 107.1,Title 47 CFR,Part 15,Class B,ICES 003 PROJECT# 8858 �h�ii�s� Production metering.ANSI C12.20 accuracy class 0.5(PV production) YR�CY Consumption metering accuracy class 2-5 DATE DRAWN 5/8/2024 To learn more about Enphase offerings,visit ennDhase.c9iD ENPHASE. Compliance,IQ Gateway UL 60601 l,CANCSA 222 No 61010-1 DRAWN BY ER IQ-C-4-4C-DS-0103-EN-US-12-29-2022 C 2022 Enphase Energy.All rights reserved Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of SHEET# PV-72 Enphase Energy,Inc Date subject to change IQ-C-4-4C-DS-0103-EN-US 12-29-2022 TITLE COMBINER SPEC /lr IRONRIDGE XR Rail'' Family XR Rail"' Family The XR Rail-' Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location,there is an XR Rail''to match. Over their lifetime. solar panels experience countless THESE DRAWINGS ARE SUBJECT To extreme weather events. Not just the worst storms in ,ears COPYRIGHT PROTECTION BY US LAW. y REPRODUCTION IN ANY FORM IS but the worst storms in 40 years. High winds capable of i N EXPRESSLY FORBIDDEN WITHOUT PRIOR ripping panels from a roof, and snowfalls weighing WRITTEN APPROVAL FROM CURRENT t RENEWABLES ENGINEERING INC. enough to buckle a panel frame. - XR Railsli'are the structural backbone Current preventing these results.They resist uplift, 11 XR10 XR100 XR1000 enewabit. protect against buckling and safely i xR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among Enalneerinc and efficiently transfer loads into the rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails It's built to handle building structure-Their superior no snow.It achieves spans up to 6 feet. wind and snow conditions while also extreme climates and spans up to 12 CURRENT RENEWABLES Spanning capability r6gUlreS fewer while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. ENGINEERING INC. 1760 CHICAGO AVE SUITE roof attachments, reducing the 6'spanningcapability 1 O'spanning capability 12'spanningcapability J-13,RIVERSIDE CA 92507 number Of roof penetrations Moderate load capability Heavy load capability Extreme load capability PHONE (951)405-T733 • Clear 8 black anodized finish Clear 8 black anodized finish Clear anodized finish WWW.CRENG.CO and the amount of Interral splices available Internal splices available Internal splices available CONTRACTOR INFO_ installation time. Rail Selection rM The table below was prepared in compliance with applicable engineering codes and standards.' Values are �' based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof CZ S Tv S Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. ELEMENT ENERGY LLC. ■ 7470 SOUND AVENUE,MATTfTUCK, •. NEW YORK,11952 PH:(631)779 7993 services@e2sys.com / Licence-ME-52689 Force-Stabilizing Curve 90 (MASTER ELECTRICIAN) Licence-HI-67461 Sloped roofs generate both vertical and lateral 120 (SUFFOLK HOME IMPROVEMENT) forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails None 140 XR10 XR100 XR1000 SCOTT CLARK is specially designed to increase strength in both directions while resisting the twisting.This unique 160 595 KERW I N BLVD, / feature ensures greater security during extreme weather and a longer system lifetime. 90 GREENPORT, NY 11944 PV SUMMARY 120 SYSTEM SIZE 20 (KWDC) STC 425 X 16 = 800 140 1[ENPHIASE 398.1 X 16 = 370 SYSTEM SIZE @240 160 (KWAC) - MODULES JINKOSOLAR 90 i..-; J KM425 N-54H L4-B .� MICRO-INV.QTY 160 MICRO IQ8MC-72-M-US INVERTERCompatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 UTILITY s AND POWER AUTHORITY XR Rails'are IronRidge`offers All XR Rails'are made of 6000-series 40 compatible with a range of tilt leg aluminum alloy,then protected with an 160 F ashFoot"and options for flat anodized finish.Anodizing prevents surface A other pitched roof roof mounting and structural corrosion,while also providing 80 160 Rev Description Data attachments. applications. a more attractive appearance. A INITIAL DESIGN 5/8/2024 120 160 - - 'Table is meant to be a simplified span chart for conveying general rail Capabilities Use approved certification letters for actual design guidance. PROJECT# 8858 DATE DRAWN 5IBY2024 0 2023 IronRidge,Inc.All rights reseived.Visit ww—sronridge.com or call 1-800-227-9523 for more information.Version 1.22 DRAWN BY ER - SHEET# PV-7.3 TITLE RAIL SPEC IRONRIDGE QuickMounf 0 Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves ^� When integrating with a home, solar attachments 11 (= THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. v _ COPYRIGHT PROTECTION BY US LAW. p REPRODUCTION IN ANY FORM IS Due to recent innovations, many asphalt shingles — _____ EXPRESSLY FORBIDDEN WITHOUT PRIOR ou have bonded courses.A mount that protects without E' WRITTEN APPROVAL FROM CURRENT p RENEWABLES ENGINEERING INC. the need to pry shingles can really speed things up. Halo UltraGrip'(HUG`) is here to respect the roof. 141", C'urrent Its Halo is a cast-aluminum barrier that encases the UltraGrip,our industrial-grade. foam-and-mastic Engineering seal.This allows HUG to accelerate the installation process and provide the utmost In waterproofing _ CURRENT RENEWABLES Miss Hit the rafter?Goodthe Still ENGINEERING INC. protection. Give your roof a HUG.` When you , got you can , _on Place another o the o o 1760 CHICAGO AVE SUITE _ •nly 2 R•Structural Screws are needed. screw. J-13,RIVERSIDE CA 92507 PHONE.(951)-4051733 WW W.CRENG.CO CONTRACTOR INFO Multi-Tiered Waterproofing ,_— HUG utilizes a multi-tiered stack of components to provide revolutionary Trusted Strength & Less Hassle waterproofing protection.The Halo cast- . aluminum,raised-perimeter foundation Structural capacities of HUG` were reviewed in �-- surrounds the UftraGnp base—a foam- p ed mastic seal combination that many load directions,with racking rail running C?SYS M _ _ prevents water intrusion by adhering cross-slope or up-slope in relation to roof pitch. 1 Ilr Sealing with the shingle surface. _11traGn ELEMENT ENERGY LLC.p` is part For further details,see the HUG certification 7470 SOUND AVENUE,MATTIUCK, QuickMount° letters for attaching to rafters and decking. NEW YORK,11952 oe. PH:(631)779 7993 IronRidge designed the HUG, in combination services@e2sys.com Licence-ME-52689 UltraGrip Seal Technology with the RD Structural Screw to streamline (MASTER ELECTRICIAN) HUG UltraGrip utilizes a state-ot-the- installs, WI11Ch means the fOIIOWIng: Licence-HI-67461 art seal design that uses a unique. (SUFFOLK HOME IMPROVEMENT) foam-and-mastic combination.The foam-backed adhesive provides an _ No prying shingles SCOTT CLARK entirely new flashing system that No roof nail interference conforms and adheres to every node 25-Year Warranty No pilot holes necessary 595 KERWIN BLVD, and cranny of composition shingles, Product guaranteed free GREENPORT,NY 11944 filling gaps and shingle step-downs — of impairing defects. No sealant(in most cases) (up to 1/8'in height) { No butyl shims needed PV SUMMARY SYSTEM SIZE (KWDC) STC 425 X 16 = 800 Attachment ' PTC 398.1 X 16 = 370 SYSTEM SIZE 5.120 @240 Loading DesignRatings (KWAC) • MODULES 16 11NKO SOLAR •� 1KM42SN-54HL4-B — MICRO-INV.OTY 16 MICRO ENPHASE IQ8MC-72-M-US INVERTER Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG p assed both Systems conform to UTILITY LONG ISLAND POWER AUTHORITY Mount HUG`to the roof rafters.the roof g LIPA) • deck,or both with our custom-engineered HUG has been and certified for the UL 441 Section UL 2703 mechanical RD(ratter-or-deck)Structural Screw.The RD tested and rated to compliance with 27"Rain Test"and and bonding Triple Rated&Certified Structural Screw anchors HUG to the roof su ort 1004 Ibs of the International TAS 100 A -95 re uirements. See om to Respect the Roof" with an EPDM sealing washer,completing pp ( ) ( ) q Rev Desc Pin Date uL 2703,441 (27) the stack of waterproofing barriers See uplift and 368 (Ibs) Building Code& "Wind Driven Rain Flush Mount Manual A INITIAL DESIGN 518/2024 Intertek TAS 100(A)-95 backside for more installation information of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. - PROJECT# 8858 �� DATE DRAWN 5/8/2024 0 2023 IronRidge,Inc.All rights reserved.Visit www.ir-patents.com for patent information.Version r DRAWN BY ER SHEET# PV-7.4 TITLE ATTACHMENT SPEC