Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50889-Z
guFFOd Town of Southold 9/12/2024 P.O.Box 1179 o _ +� 53095 Main Rd ti01 �a Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45543 Date: 9/12/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1687 Rocky Point Rd,East Marion SCTM#: 473889 Sec/Block/Lot: 30.-3-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/9/2024 pursuant to which Building Permit No. 50889 dated 7/l/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels as applied for The certificate is issued to Donson,Nathaniel&Miriam of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50889 08/29/2024 PLUMBERS CERTIFICATION DATED AuttiorizJ4 dignature o�Su�Fot,t�o TOWN OF SOUTHOLD aye BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE oy •� �'��� SOUTHOLD, NY 6Jpl�" BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 60889 Date: 7/1/2024 Permission is hereby granted to: Donson, Nathaniel 898 Helen St Teaneck, NJ 07666 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1687 Rocky Point Rd, East Marion SCTM #473889 Sec/Block/Lot# 30.-3-11 Pursuant to application dated 5/9/2024 and approved by the Building Inspector. To expire on 12/31/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector �o��OF SOU��OIo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlini-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Nathaniel Donson Address: 1687 Rocky Point Rd city.East Marion st: NY zip: 11939 Building Permit#: 50889 Section: 30 Block: 3 Lot: 1 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunation Solar License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED F1 Exit Fixtures Sump Pump Other Equipment: 15.54kW Ropof Mounted PV Solar Energy System w/ (37)REC420AApure Modules, Enphase Gateway Combiner w/ (4)220Breakers & (1)215For Monitor, 60A Disconnect, Lineside- Notes: Tapped in Main Panel Solar Inspector Signature: Date: August 29, 2024 S.Devlin-Cent Electrical Compliance Form SOGIyo� TOWN'OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECT ION [ ]- FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [✓]'FINAL art [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)' [ ] CODE VIOLATION [ ] PRE.C/O [ ] RENTAL REMARKS: dl 2 eizeQ- DATE 0' a�-v? INSPECTOR OF SOUIyO� 57o ES9 1 (G9 61� 421a cj_� <pj- * TOWN OF SOUTHOLD BUILDING DEPT. "coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE-& CHIMNEY [ ] ,FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]- FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ]. RENTAL REMARKS: o—rrA DATE INSPECTOR 1 f Fisher Engineering Services, P.C. 509 Sayville Blvd - Sayville-New York 11782 Phone: (631) 786-4419 July 19, 2024 Town of Southold Post Installation Certification Subject: Engineer Statement for Solar Roof Installation EDonson Residence - 1687 Rocky Point Road, East Marion,NY 11939 Permit# 50889 Installation Date: 7/11/2024 Inspection Date: 7/15/2024 To whom it may concern, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the as-built plans and is certified by William G. Fisher, PE to be in compliance with the minimum requirements of the Town,the 2020 Residential Code of New York State, 2018 International Residential Code (2018 IRC), Long Island Unified Solar Permit Imitative(LIUSPI), and National Electric Code 2017, and the provisions of ASCE 7-16. �EpF NEW!-0 . Sincerely, William G. Fisher, P.E. ECE � � C Licensed Professional Engineers A UG 2 2 2024 Building Department Town of Southold Architectural Design•Residential•Light Commercial Additions-Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections FIELD INSPECTION REPORT DATE COMMENTS t v1.b C) t� FOUNDATION (IST) ------------------------------------ FOUNDATION (2ND) z 0 H ROUGH FRAMING& O PLUMBING y . O INSULATION PER N.Y. ►� STATE ENERGY CODE a ok, FINAL ADDITIONAL COMMENTS d ro H °z x r� �d ro o�SUfFO(��oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y? Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ' PERMIT NO. ✓00 Building Inspector: 2024 MAY Applications-and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,anttPlEFit Owner's Authorization form(Page 2)shall be completed. Date: S(a aq OWNER(S)OF PROPERTY: - Name:Nathaniel Donson SCTM#1000-30-3-11 Project Address:1687 Rocky--Point Road,_East Marion,_NY 11939 Phone#:201-835-9969 Email:nathanieldonson345@gmail.com Mailing Address: 1687 Rocky_Point Road,East Marion, NY 11939 CONTACT PERSON: Name: Evelyn Polvere/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma.--NY 11779 Phone#: 631-750-9454 ext 346 P_ Email __i_: ermitg@ tin sunation.com � _ � DESIGN PROFESSIONAL INFORMATION: Name: William Fisher Mailing Address:509 Sayville_Blvd, Sayville, NY 11782 Phone#:631-786-4419 Email:bill@fisher-ny-.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems — Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email: ermittin sunation�com --- -P_ - - g °�-_ -- -- DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ `tD149q. Do Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes RNo IF YES, PROVIDE A COPY. ❑Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction.of buildings, additions,alterations or for removal or demolition as herein described.,The applicant agrees to comply with all applicable laws,ordinances,building code, 'housing code and regulations and to admit authorized inspectors on.premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name) Scott Maskin BAuthorized Agent ❑Owner _ .. . --.__ Signature of Applicant: Date: S I - - - ------- -- - - - - -- - - -- -- - -_ - - a- -- - - - - STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this IJ Q29Aday of 204 Notary Public ' LYNN VITA Notary Public, State of NewYo Registration #01VI5068399 PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County(Where the applicant is not the owner) my Commission Expires Oct.28, a Nathaniel Donson residingat 1687 Rocky Point Road East Marion, NY do hereby authorize Scott Maskin to apply on 4myaalfTown of Southold Building Department for approval as described herein. V A/ br Owner's Signature Date Nathaniel Donson Print Owner's Name 2 d OS�gfp��C BUILDING DEPARTMENT-Electrical Inspector OGyA TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 o ^ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr _southoldtownny..go-v-n-seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION' ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permiftingQsunation.com Address: 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 Ell. JOB SITE INFORMATION (All Information Required) ' Name: Nathaniel Donson Address: 1687 Rock -Point Road East Marion NY 11939 _ Cross Street: Phone No.: 201-835-9969 BIdg.Permit#: -r p�8� email: nathanieldonson345@gmaii.com Tax Map District:. 1000 Section:__30 Block: 3 _ Lot: 11 BRIEF DESCRIPTION OF WORK (Please Print Clearly) .__Installation of solar panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) i Service Size 1 Ph 3 Ph Size: -A #Meters Old Meter# . New Service- Fire Reconnect- Flood Reconnect-Service Reconnected-Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT.DUE.WITH APPLICATION U � Request for Inspection Formals 1' �I�vl2 gSUrFp/ c._ BUILDING DEPARTMENT- Electrical Inspector j �Gy� TOWN OF SOUTHOLD .� Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr a(�southoldtownny.gov seand ansoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/21/2024 Company Name: Sunation Solar Systems, Inc. Electrician's Name: Scott Maskin License No.: 33412-ME Elec. email:closeout@sunation.com Elec. Phone No: 631-750-9454 [E]I request an email copy of Certificate of Compliance Elec. Address.: 171 Remington Blvd., Ronkonkoma, NY 117.79 JOB SITE INFORMATION (All Information Required) Name: Nathaniel Donson Address: 1687 Rocky Point Road Cross Street: Phone No.: 201-835-9969 Bldg.Permit#: 5089 ,SD 8$q email: nathanieldonson345@gmail.com Tax Map District: 1000 Section: 30 Block: 3 Lot: 11 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 15.54 KW Roof Mounted Solar Photovoltaic System Including: 37 REC420AA Pure 2 modules w/37 Enphase IQ8PLUS Microlnverters. 60 Amp fused service disconnect. Fused at 40 Amps.1-Enphase Envoy combiner box with 2 20amp breakers. Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: 0 YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments NY S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAA"AA 753118816 GCG RISK MANAGEMENT INC , AN NFP COMPANY 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER I CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 43689 01/01/2024 TO 01/01/2025 12/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND //"" 4 DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 601025760 1111111111111111111 nnu nill niimm lllll lllll nu[lmllm1 Hill iuu om�Im full E I 00000000000122055844 Form WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-21606702] U-26.3 64 [00000000000122055844][0001-000021606702][96Z][16282.08][CerL.NoP-CERT 1][01-00001] PORK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that Carrie 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured SUNATION SOLAR SYSTEMS 631-750-9454 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"'I a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/01/2022 to 09/30/2024 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. Ej B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 9/26/2023 By "0' 4f (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: if Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200,Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 46,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111 I III DB-120.1 (iiuiiiiuimiiillll�l 7 ® DATE(MMIDD/YYYY) ,d►�o2o CERTIFICATE OF LIABILITY INSURANCE 01/25/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLYAND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Shelby Gierdal NAME: Christensen Group PHONE,/ Ext: (952)653-1000 FAX Na: (952)653-1100 9855 West 78th Street,Ste 100 E-MAIL sgierdal@chdstensengroup.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# Eden Prairie MN 55344 INSURERA: James River Insurance Company 12203 INSURED INSURER B: Crum&Forster Specialty Insurance Company 44520 SUNation Solar Systems,Inc. INSURER C: Ascot Insurance Company 23752 171 Remington Blvd INSURER D: INSURER E: Ronkonkoma NY 11779 INSURER F: COVERAGES CERTIFICATE NUMBER: 12/01/23-24 SUNation REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. I�TR TYPE OF INSURANCE INSD WVD POLICYNUMBER MM/DDYEFF MMIDD POLICY FxP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE OCCUR PREMISES Ea occurrence $ 50,000 MED EXP(Any one person) $ Excluded A P0000000282 12/01/2023 12/01/2024 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE UMITAPPUES PER: GENERALAGGREGATE $ 2,000,000 POLICY F PEa LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: AUTOMOBILE LIABILITY Ea erB.dideDtSINGLE LIMIT $ 1,000,000 X ANYAUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED 133-756069-5 12/14/2023 12/01/2024 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident X UMBRELLALUIB X OCCUR EACH OCCURRENCE $ 3,000,000 A EXCESS LIAB CLAIMS-MADE Po00000D283 12/01/2023 12/01/2024 AGGREGATE $ 3,000,000 DED I X RETENTION$ 0 PER _ $ WORKERS COMPENSATION STATUTE ERH AND EMPLOYERS'LIABILITY YIN ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Newly BuilUAcqur Bldgs $500,000 Property/Builders Risk C IMMA2310001919-01 12/01/2023 12/01/2024 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Main Road AUTHORIZED REPRESENTATIVE (� Southold NY 11971 CJ2,`-- J,�`- ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Suffolk County Dept. of Labor, Licensing & Consumer Affairs i r HOME IMPROVEMENT LICENSE Name SCOTT MASKIN Business Name SUNation Solar Systems Inc This certifies that the bearer is duly licensed License Number H-44104 by the County of suffolk Issued: 03/06/2008 W�&,v& T. Roge,,ry Expires: 03/01/2026' Commissioner Suffolk County Dept. of k Labor, Licensing & Consumer Affairs _ MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN Business Name SUNATION SOLAR SYSTEMS INC This certifies that the bearer is duly licensed License Number ME-33412 by the County of suffolk Issued: 06/24/2003 R&S&" D rag o-- Expires: 06/01/2025 Commissioner 0 46 Enphase A/C Branch Circuit(typ.) UTILITY SERVICE Enphase Microinverter(typ.) PSEG UtExisting SUNATION �17i%qMete; Account#-9f C-i-D 9 COMBINER Meter#-98438201 Module J-Box(typ.) PANEL 1201240V SUNation Solar Systems 171 Remington Blvd. SUPPLY SIDE CONNECTION Ronkonkoma,New York 11779 y L (631)-750-9454 PV Module(typ.) NYSERDA INSTALLER NUMBER 4355 EGC Attached To Rail(typ.) i MAIN ENPHASE GATEWAY JOB NUMBER 1, (No loads.monitoring onlylj 1 5 24146 2P20A 2P15 Circuit#1 ENPHASE BRANCH CIRCUIT#1 2P20A CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT#2 Circuit#2 2P20A TAG CONDUCTOR CONDUIT RUN Circuit#3 M70A AINIM r] ENPHASE BRANCH CIRCUIT#3 A F TYPE GAUGE QUANTITY TYPE SIZE LENGTH 2P20A ENPHASE BRANCH CIRCUIT#4 i Circuit#4 1 Enphase Q-Cable 12 8 N/A N/A 15, Ce) EGC L G CY) PANEL 0 0. T_ 2 10 N/A N/A 3 L MAIN Type NM — 2 ENPHASE A/C SERVICECV 3 THWN-2 10 8 PVC SCH.80 1.25" 15' 3 _�TQ COMBINER DISCONNECT SE >_ ROOF ATTIC EXTERIOR z =_GC 10 1 PVC SCH.80 1.25" 15' SERVICE RATED- � 4 ENCLOSURE 6 0 0 4 THWN-2 4 3 PVC SCH.80 1.25" 10, MIN.60A .rLr) EGC 8 1 PVC SCH.80 1.25" 10, MIN.22k AIC 2 z co C2 - 10, (1) � Cz 5 �HWN-2 4 3 PVC SCH.80 1.25" EXTERIOR BUILDING 4 -0 U) 0 DISCONNECTING MEANS GROUNDING cz 0 1 6 EC N/A N/A 10, ELECTRODE CD LLI 0 Ir 0 Cc -6 LL Cd cz K 0 0 W U) Cn 0 C: Circuit# PV Module Qty. Micro-Inverter aty. Maximum AC Operating Current 0 I co REC420AA Pure 2 11 Enphase WA-72-2-US 11 15.95 A 2 REC420AA Pure 2 11 Enphase II08A-72-2-US 11 15.95 A 0 cz 3 REC420AA Pure 2 8 Enphase II08A-72-2-US 8 11.6 A r__ 00 C.0 4 REC420AA Pure 2 7 Enphase II08A-72-2-US 7 10.15 A Maximum AC Operating Current(Total) 53.65 A E1 = 1 ONE-LINE DIAGRAM Fisher Engineering a' g neering Services, P.C. 509 Sayville Blvd • Sayville •New York 11782 Phone: (631) 786-4419 May 1, 2024 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Donson Residence- 1687 Rocky Point Road, East Marion,NY 11939 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system(photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2020- Residential Code of New York State(2020 RCNYS), Long Island Unified Solar Permit Initiative(LIUSPI), 2017 National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the roof utilizing lag screws that have been designed for wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x8" & 2"x4" on 16" c.c., with an actual span of 14'-2.5", 14'-3.5", 8'-911, 18'-2", with plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, �' NE'C' w ro William G. Fisher, P.Et) . h Q Licensed Professional Engineer r 0? Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections SOLAR'S MOST TRUSTED ® RE C 0 Mons . . . . COMPACT PANEL SIZE EXPERIENCE 430WP RE[ 25 YEAR 20. PROTRUST ` VV6 FTZ WARRANTY 22.2% EFFICIENW LEA■- F ELIGIBLE ROHS CC IANT PERFORMANCE , %C-C PRODUCT 5PEEIFI[ATIDN5 734+01 GENERAL DATA -- -- 36.4±_0.1 _ 18.5 i0.1 Cell type 132 half-cut REC heterojunction cells with lead-free, I ----- gapless technology,6 strings of 22 cells in series 6.05 + . 0.12 in solarglass with anti-reflective surface treatment � Glass: 49.2 in accordance with EN 12150 Backsheet: Highly resistant polymer(black) 0.24±0.01 Frame: Anodized aluminum(black) b Junction box: 3-part,3 bypass diodes,lead-free o I P68 rated,in accordance with IEC 62790 c N 0.43±0.01 Connectors: StaubliMC4PV-KBT4/KST4(12AWG) o in accordance with IEC 62852,IP68 onlywhen connected Cable: 12 AWG solar cable,49.2+49.2 in 0.8±0.02 111� - in accordance with EN 50618 + 49.2 6 �! I Dimensions: 73.4 x 40.9 x 1.2 in(20.88 sq-ft) ' 6.05 _ ---- - Weight: 47.6lbs(21.6 kg) .- 1.8 0.9 27.3±o.1 - Origin: Made in Singapore - - 1-2 Measurements in inches[mm] ELECTRICAL DATA Product Code':RECxxxAA PURE 2 CERTIFICATIONS Power Output-PMnx(WP) 400 410 420 430 IEC 61215:2016,IEC 61730:2016,UL61730 Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID IEC61701 Salt Mist Nominal Power Voltage-V,,,PP(V) 41.1 41.6 42.2 42.8 IEC62716 Ammonia Resistance v Nominal Power Current-1M,P(A) 9.74 9.86 9.96 10.05 UL61730 Fire Type 2 Open Circuit Voltage-Voc(V) 48.5 48.8 49.1 49.3 IEC62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone(35mm) Short Circuit Current Isc(A) 10.60 10.67 10.74 10.81 IEC62321 Lead-freeacc.to RoHS EU 863/2015 Power Density(W/ft') 19.2 19.6 20.1 20.6 ISO 14001,ISO 9001,IEC 45001,IEC 62941 Panel Efficiency(%) 20.6 21.1 21.7 22.2 v OE 0- E a Power Output PMnx(WP) 304 312 320 327 Ft"k -eedPr F- NominalPowerVoltage-VMPp(V) 38.7 39.2 39.8 40.3 TEMPERATURE RATINGS' V O Nominal Power Current-I (A) 7.86 7.96 8.05 8.12 2 MPP Nominal Module Operating Temperature: 44°C(±2°C) Z Open Circuit Voltage-Voc(V) 45.7 4S.8 46.0 46.2 Temperature coefficient ofPMAx: -0.24%/-C o Short Circuit Current-I,(A) 8.50 8.62 8.68 8.73 Temperature coefficient ofVoc: -0.24%/°C Values at standard test conditions(STC:air mass AM 1.5.irradiance 10.75 W/sq ft(1000 W/m'),temperature 77"F(25°C),based on a production spread with a tolerance ofP V &1 13%within one watt class.Nominal module operating temperature(NMOT:air mass AM 1.5.irradiance 8G0 W/M2, Temperature coefficient ofl5C: 0.04%/-C u temperature 68-F(20°C).mndspeed3.3ft/s(lm/s).*Where x indicates the nominal power class(P.)at STC above. 'The temperature coefficients stated are linear values ° a MAXIMUM RATINGS WARRANTY DELIVERY INFORMATION Operational temperature: -40...+85°C Standard REC ProTrust Panels per pallet: 33 `o System voltage: 1000V Installed byan REC Panels per cube container: 792(24pallets) No Yes Yes - Certified Solar Professional - Test load(front): +7000 Pa(1461bs)Ift2)' System Size All 425 kW 25 500 kW Panels per 53 ft truck: 858(26 pallets) Test load(rear): 4000 Pa(83.5 Ibs/ft2)- Product Warranty(yrs) 20 25 25 Series fuse rating: 25A Power Warranty(yrs) 25 25 25 LOW LIGHT BEHAVIOUR cc Reverse current 25A Labor Warrant 0 25 10 Typical low irradiance performance of module at STC: a : Warranty 'See installation manual for mounting instructions. Power in Year 1 98% 98% 98% 2E Design load-Test load/1.5(safety factor) Annual Degradation 0.25% 0.25% 0.25% m a a Power in Year 25 92% 92% 92% w See warranty documents for details.Conditions apply -- m o z a Available from. m m �Irradiance(W/m.) Founded in 1996,REC Group is an international pioneering solar energy company dedicated to empowering consumers REC Solar PTE.LTD. REC with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20 Tuas South Ave.14 carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. post@recgroup.com www-recgroup.com i s EA PHASE I _ I IQBM and IQBA Microinverters Our newest I08 Microinverters are the industry's first microgrid-forming,software defined Easy to install microinverters with split-phase power conversion capability to convert DC power to AC Lightweight and compact with plug-n- power efficiently.The brain of the semiconductor-based microinverter is our proprietary play connectors application specific integrated circuit(ASIC)which enables the microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed Power Line Communication(PLC) digital logic and has superfast response times to changing loads and grid events,alleviating between components constraints on battery sizing for home energy systems. Faster installation with simple two-wire cabling Enphase High productivity and reliability Produce power even when the grid is down' More than one million cumulative hours Part of the Enphase Energy System,I08 IQ8 Series Microinverters redefine of testing Series Microinverters integrate with the reliability standards with more than one Class 11 double-insulated enclosure IQ Battery,IQ Gateway,and the Enphase million cumulative hours of power-on Optimized for the latest high-powered ADD monitoring and analysis software. testing,enabling an industry-leading PV modules limited warranty of up to 25 years. Microgrid-forming Complies with the latest advanced grid support" Remote automatic updates for the 0 latest grid requirements Connect PV modules quickly and easily I08 Series Microinverters are UL listed Configurable to support a wide range to IQ8 Series Microinverters using the as PV Rapid Shutdown Equipment and of grid profiles included Q-DCC-2 adapter cable with conform with various regulations,when Meets CA Rule 21(UL 1741-SA)and IEEE plug-n-play MC4 connectors. installed according to manufacturer's 1547:2018(UL 1741-SB 3r°Ed.) instructions. Note: I08 Microinverters cannot be mixed together with previous generations of Enphase microinverters(I07 Series,I08 Series,etc)in the same system. 'Only when installed with IQ System Controller 2,meetsUL 1741. ••IQBM and IQBA support split-phase,240V installations only. ®2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters, and other names are trademarks of Enphase Energy,Inc.Data subject to change. I08MA-I2A-DS-0069-03-EN-US-2022-12-27 IQ8M and IQ8A Microinverters INPUT DATA r Commonly used module pairings' w 260-460 295-500 Module compatibility 54-cell/108 half-cell,60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 30-45 32-45 Operating range V 16-58 Min./Max.start voltage v 22/58 Max.input DC voltage V 60 Max.continuous input DC current A 12 Max.input DC short-circuit current A 25 Max.module IK A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA Q: Q•, Peak output power VA 330 366 Max.continuous output power VA 325 349 Nominal(L-L)voltage/range2 V 240/211-264 Max.continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over 2 3 cycles Arms Max.units per 20 A(L-L)branch circuit' 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85leading-0.85lagging Peak efficiency % 97.8 97.7 CEC weighted efficiency % 97.5 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -40°C to+60*C(-40°F to+140"F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(H x W x D) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm 0.2") Weight 1.08 kg(2.38lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB 31d Ed.).FCC Part 15 Class B,ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)Pairing PV modules with wattage above the limit may result in additional clipping losses.See the compatibility calculator at https://Iink.enphase.com/module-compatibility.(2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-12A-DS-0069-03-EN-US-2022-12-27 SERIES 100 FLASHED L FOOT SnapNrack Residential PV Mounting Systems The SnapNrack line of solar mounting systems is designed to reduce total installation costs. The system features technical innovations proven on more than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • V slotted bolt connection • 1" spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at No Cutting of shingles www.snapnrack.com/contact • SnapNrack- Patent Pending PV MG :Aing Systems { Oa O -oo,/Ci,Asse^-)oleo(1'spacer sold seoarately) -lasneo _ -oo:,Cr,-'ar:s(' soace,solo seoa,,ely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions -SNAFNRACK CHANNEL NUT 94ARRACK 92 DEGREE L-FOOr,CLEAR Ot- S/1618 FLANGE NUT -5/1618%1Q1 BOLT WETN SMUT LOO(MMSNER 40 -SNAP RACK COMFOSMON FLASHING 3.13 -SNAFIRACK L-FOOT BASE -1 -- .08 SnapNrack Flashed Foot TechnicalData Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship Snap �,N rack rFv Mounting Systems (877) 732-2860 www.SnapNrack.com 8 Printed on recycled paper using soy based inks. O 2013 by SnapNrack PV Mounting System All rights reserved SERIES 100 ROOF MOUNT SYSTEM SnapNrack Solar • • Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive - _ down costs and improve installation quality on more than 350 MW of solar -- installations. ._ Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System ` is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware. The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules �L LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Bolt with Split- Splice Insert Split-Lock Washer Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding SnapNrack Bonding Adjustable End Bonding Stainless Channel Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug _ Assembly --i—'— (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End CIamP(UEC)Wave UEC Pull Strap —UEC Wedge Stainless Steel Bolt -- with Flat Washer IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly Serrated Stainless� SnapNrack SnapNrack Bonding SnapNrack Channel Nut Rubber Steel Flange Nut Bonding Stainless Rain Collar Channel Flange Nut Serrated Stainless Nut Steel Flange Bolt SnapNrack Stainless SnapNrack 92 Degree Flange Mill Finish L Foot Bolt Standoff SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding J SnapNrack Bonding SnapNrack Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack • • UL Technical Data Patent Pending Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish • Clear and black anodized aluminum • Mill Finish on select components Installation • Quick and efficient mounting • Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) Snapl\ rack- lting (877) 732-2860 www.SnapNrack.com 4 Printed on recycled paper using soy based inks. O 2015 by SnapNrack PV Mounting System.All rights reserved. • ®-UTILR PROPOSED RESIDENTIAL PLAN KEY �-SERVICECE DISC DISCONNECT PV1_0 COVER SHEET I: SUPPLY SIDE CONNECTION PHOTOVOLTAIC SYSTEM Al-1 PARTIAL ROOF PLAN -AUTOMATIC TRANSFER SWITCH Al-4 ROOF ACCESS PLAN 0 GAS METER (EXT) Q-MAIN SERVICEPANEL S1-1 STRUCTURE C IQ UNDERGROUND - �' -- SERVICE IExT1 SUNATION SOLAR SYSTEMS NYSERDA 4355 E1-1 ONE-LINE DIAGRAM ®'SUB PANEL DSC =_ (4)PROPOSEDPVMODULES T-WIRELESS ROUTER 171 REMINGTON BOULEVARD INSTALLER ROOF E2-1 PV LABELS MSP E88 RONKONKOMA,NEW YORK 11779 NUMBER ®-INVERTER G1-1 PV PHOTOS ©-ENPHASE 10 COMBINER Donson Residence ©-PANEL PHOTOVOLTAIC (G) Z O _ 1687 Rocky Point Road, East Marion, NY 11939 -ELECTRIC VEHICLE CHARGER Q g ®-ENPHASEENVOY Z Z ROOF ACCESSDrawn By: J. DellaRocca-05/01/2024 -SENSE CONSUMPTION MONITOR -36�8'. ®-AC DISCONNECT ROOF /' -TESLA GATEWAY f ACCESS- l i� ®-TESLA POWERWALL �P 0m G. " -ENPHASE IO SYSTEM CONTROLLER ROOF ACCESS 0-ENPHASE 10 LOAD CONTROLLER -3r- - (11)PROPOSED PV MODULES ENPHASE 10 10 BATTERY r— ®-ENPHASE 103 BATTERY ` W ®-GENERATION PANEL � yg•. [f 0-BACKED UP LOADS CENTER \ .s 0746`�9 � -18"-VENTILATION i - �`Cc `• ©-VENT PIPE 18"-VENTILATION FRONT OF HOUSE- V/r-/ EXTERIOR LOCATION \ 0 _\� FACING STREET OR 1ST FLOOR LOCATION ,� 'I, Roof 5 5 DRIVEWAY Building Review Note -BASEMENT LOCATION ACCESS P: P .tB•- Z Z Town building examiner has received the enclosed document for minimum acceptable -GARAGE LOCATION Uj Uj > plan submittal requirements of the town as specified in the building and/or Residential i Code of the State of New York. This review does not guarantee compliance with that = code. that responsibility is guaranteed under the seal and signature of the New York PROPOSED PV SYSTEM (3)PROPOSED PV MODULES State licensed design professional of record. That seal and signature has been interpreted as an attestation that,to the best of the licensee's belief and information the work in this document is: Module Type/Qty: (37)REC420AA Pure 2 i • Confoarms te with governing codes applicable at the time of submission Module Dimension: 73.4"x 40.9"x 1.2" — • Conforms with reasonable standards of practice and with view to the 19)PROPOSED PV MODULES - \ safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 47.6 Ibs/2.27969348659004 PSF licensee. Poor Micro Inverter: (37)Enphase 108A-72-2-US ASS System DC Rating: 15.54 kW � Structural Statement - • The existing structure is adequate to support the new loads imposed by the System AC Rating: 12.876 kW/AC 40VIED AS NOTED photovoltaic module system Including uplift and shear. The existing rafter sizes and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. CA Aurora Estimated AC Production: 14,623 kWh/yr PV Notes F .H 1 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground NOTIFY BUILDING DEPARTME AT clearance,roof access points,access pathways and ventilation systems shall be 631-765-1802 8AM TO 4PM FOR THE provided where necessary. An in depth description of each applicable code reference and exception for any codes is depicted on the PV-1 plate of this FOLLOWING INSPECTIONS: drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the 1. FOUNDATION-TWO REQUIRED solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more FOR POURED CONCRETE N than 6-inches above the surface of the roof. 2. ROUGH-FRAMING&PLUMBING 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. 3. i �:>�LATION Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN 4. FINAL-CONSTRUCTION MUST inspection. SCALE:N.T.S. BE COMPLETE FOR C.O. This PV system has been designed to meet the minimum design standard for building A;_.L CONSTRUCTION SHALL MEET THE an other structures of the ASCE 7-16 and the 2020 New York State Residential REQUIREMENTS OF THE CODES OF NEW YCRK STATE. NOT RESPONSIBLE FOR COMPLY WITH ALL CODES OF PV1 0 DCSIGN OR CONSTRUCTION ERRORS COVER PAGE JOB# 24146 a"s"s REQUIRED AND CONEW YORK STATE & DITIONS CODES OCCUPANCY OR NDITIONS OF /."EC REVISION # N/A ELECTRICAL USE IS UNLAWFUL NINGBOAQ SUNATION INSPECTION REQUIRED TEES REVISED BY N/A WITHOUT CERTIFICA OF OCCUPANCY X �i ���oR+ 'S �0 2G.SYJ - ^I — • W 3 ❑ 45 �✓Q ��.0746`�9. W 0 'B'-zYr• Cr ROOF 4 SUNATION SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 HOUSE ROOF 2 T-, . -T NYSERDA ,\ INSTALLER NUMBER 435S • JOB NUMBER CIRCUIT 3 — -� — • F- 24146 . w • CIRCUIT 1 CIRCUIT 4- RIDGE 20-8" a2 - N W Z N C C7 Z d — _j a4 zyz 0 g rn m C H N.al o • ROOF 1 Q m w-"Y2' HOUSE y m t ROOF 3 x p m W tr "• W -o m Q® Z o o m O C cc W pE CIRCUIT 2 'o T ,rn,�• N d m T GUTTER 0 3 0 F0 Cc 0 << R.R.-7XB" �� RO.C. � — ®,8. Roof# Roof Description Modules Azimuth Tilt Pitch Attachment Spacing: Portrait Attachment Spacing: Landscape Interior Edge Corner Interior Edge Corner 1 FOH East Roof 11 105° 310 8.3/12 48" 32" 16" 64" 48" 64" 1/8" = 1 -0" I 2 BOH West Roof 19 285° 300 8/12 48" 32" 16" 64" 48" 64" 3 BOH Lower South Roof 3 195° 140 3.7/12 32" 16" 1 16" 64" 48" 32" A1 = 1 4 1 FOH Lower East Roof 4 105° 210 5.6/12 48" 32" 16" 64" 64" 4811 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS (NY) R324.6 Roof access and pathways. Roof access, pathways and OF setback requirements shall be provided in accordance with Sections r`P�`�am G•F �� R324.61 through R324.6.2.1. Access and minimum spacing shall be �` ell required to provide emergency access to the roof,to provide pathways F to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. ,. Exceptions: �p °.074659 J i ,J• kS$ 1. v 1. Detached, nonhabitable structures, including but not limited to fit/ detached garages, parking shade structures, carports, solar trellises and similar structures, shall not be required to provide roof access. 2. Roof access, pathways and setbacks need to be provided (ExT) - j UR where the building official has determined that rooftop AC IQ /—UNDERGROUND operations will not be employed. SD - (4)PROPOSED PV MODULES / SERVICE (ExT) 3. These requirements shall not apply to roofs with slopes of two MSp ACCESS r� SUNNTION units vertical in 12 units horizontal(17-percent slope)or less == -36- [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SUNation Solar Systems / (G) o o 171 Remington Blvd. roof planes from lowest roof edge to ridge and not less than 36 inches r r Ronkonkoma,New York 11779 (914 mm)wide, shall be provided on all buildings. Not fewer than one < < (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. LU w AOOESS For each roof plane with a photovoltaic array, a pathway not less than ERD 36 inches (914 mm) wide shall be provided from the lowest roof edge 7 m' IN SALLE 4355 INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an ACOCOESS NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. - W. Pathways shall be over areas capable of supporting fire fighters JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal ROOF AC3fi obstructions such as vent pipes, conduit, or mechanical equipment. SS \� % ^�J �� Pathways on opposing roof slopes shall not be located along the same / / (11)PROPOSED Pv MODULES L I plane as the truss, rafter, or other such framing system that supports \ j the pathway. ACCESS 771 Exception: -18"-VENTILATION -18"-VENTILATION FRONT OF HOUSE- m 1. Access pathways shall not be required on roof slopes containing /, ] / photovoltaic modules, panels, or an array where the opposing o o FACING STREET OR Q a j DRIVEWAY } o or adjacent roof slope is an access roof. ACCESS � n z c\ �- W W / zG o b Access Roof-A roof surface that: ' ' F o CD g 1. Can be accessed from the ground by the fire service. (3)PROPOSED Pv MODULES J -2 U) 0 2. Is capable of providing fire service access to the ridge or peak o —-- p LU 0 of an opposing or adjacent roof surface that contains /,, LL Z o o 5 photovoltaic modules, panels,or an array. W C 3. Is relatively free of vents,skylights,conduits, mechanical (1s)PROPOSED Pv MODULES ~ O a equipment and other such obstructions. N 0- m 4. Does not contain photovoltaic modules, panels or an array, or is RAF 3 a single ridge roof where the maximum edge to edge width of ACCESS o 2 the photovoltaic panel system does not exceed 33 percent of 36Co o the ridge length. cn [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be located less than 18 inches(457 mm)from a horizontal ridge. [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches (914 mm)wide shall be provided to the emergency escape and rescue opening. 3/32" = 1'-0" A1 =4 ROOF ACCESS PLAN Typical Attachment Method SNAP WRACK RAIL RIDGE RIDGE— LFOOTA DR IL ASS MBLY PHOTOVOLTAIC 20'-11.5" PHOTOVOLTAIC 10'-5.5" SNAP'N'RACK MODULE MODULE FLASHING ALUMINUM \ 3/4"MODULE SPACING 3/4"MODULE SPACING BETWEEN ROWS AND BETWEEN ROWS AND O SUNNTION COLUMNS(TYP.) \ COLUMNS(TYP.) SUNation Solar Systems RAIL RAIL (1)5/16"x s"0 LAG BOLT 171 Remington Blvd. WITH FLAT WASHER (1)LAYER COMPOSITE Ronkonkoma,New York 11779 \ SHINGLE (631)-750-9454 RAFTER RAFTER SNAP'N'RACK BASE PLATE NYSERDA 2' X 8"/ 16" O.C. 2"X 4"/16" O.C. FASTENED TO RAFTER I / INSTALLER 43515�NUMBER JOB NUMBER _ PLYWOOD DECKING 24146 SOFF" SOFFR (TYP,) J EXTERIO EXTERID WALL WALL WOOD FRAMING . (TYP.) 18'-2" _� — _ 8'-9"- owl ATTACHMENT TYPE APPLIED TO-ROOF"TYP" ROOF SECTION (TYP.)- ROOF"1,2,4" ROOF SECTION (TYP.) - ROOF"3" M SCALE: N.T.S. SCALE: N.T.S. rn T N Z N O O� Z U CW O SOLAR MODULE FRAME NOTE:3/4"SPACING F- U BETWEEN MODULE ROWS Q Rafter Size/S Spacing Max Span Layers Sheathing AND COLUMNS. (n CZ V Roof# P 9 P Material Y 9 T o� (D Lu �o 5.5• 1 2 x 8 /16 O.C. 14-2.5 Composite Shingles 1 Plywood oo° o HEIGHT ADJUSTABLE Z o o a- — ca OO - L-FOOT(TYP.) _ 2 2"x 8"/16"O.C. 14'-3.5" Composite Shingles 1 Plywood END CLAMP w U) p (TYP.) H O Composite Shingles Plywood 3 2"X 4" /16"O.C. 8-9 P 9 1 YW OOOO OO ��SNAP'N'RACK N � O � 4 2"x 8"/16"O.C. 18'-2" Composite Shingles 1 Plywood -6°8 °Ooo° e.o• �P) RAIL ap °° ° T� Y C HEIGHT OFF OF ROOF SURFACE O Q FIT MINI 2 (TYP.) 00 Typical Module PEST WRAP CUT AWAY FOR T Side Profile CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX MEAN ANNUAL GROUND SNOW SPEED(MPH.) TOPOGRAPHIC SPECIAL WIND ZONE [WIND BORNE DEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED TEMPERATURE S 1 1 LOAD EFFECTS ZONE 20 PSF 140 B NO 2 B SEVERE T-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE OF NFL 10 0,C174659 \" Enphase A/C Branch Circuit (typ.) UTILITY SERVICE Enphase Microinverter(typ.) Existing PSEG Meter SUNATION COMBINER Account#-gstia96oso3 PANEL Meter#-98438201 Module J-Box(typ.) i 1201240V SUNation Solar Systems \; SUPPLY SIDE CONNECTION 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 —PV Module(typ.) _ INSTALLER S 200A4355 EGC Attached To Rail(typ.) MAIN NUMBER MAIN ENPHASE GATEWAY JOB NUMBER (No bads,monitoring onN) 5 2P20A 2P15A 24146 Circuit#1 Q+ CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT#1 2P20A TAG CONDUCTOR CONDUIT RUN 2P2 #2 ENPHASE BRANCH CIRCUIT#2 2P20A 7UA 1 ENPHASE BRANCH CIRCUIT#3 Cin uit#3 J TYPE GAUGE QUANTITY TYPE SIZE LENGTH MAIN ENPHASE BRANCH CIRCUIT#4 Ci� �q 1 Enphase Q-Cable 12 8 N/A N/A 15' 0) 2 Type NM 10 8 N/A N/A 30' EGC G IS G rn MAIN r 3 HWN-2 10 8 PVC SCH.80 1.25" 15' 1 2 3 ENPHASE A/C SERVICE N GC 10 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR 10 COMBINER DISCONNECT PANEL Z N SERVICE RATED 4 HWN-2 4 3 PVC SCH.80 1.25" 10' 4 ENCLOSURE 6 p CD MIN.60A i L0 GC 8 1 PVC SCH.80 1.25 10 MIN.22k AIC Z CZ CD 5 HWN-2 4 3 PVC SCH.80 1.25" 10' — O c EXTERIOR � G 6 EC 4 1 N/A N/A 10 DISCONNECTING MEANS BUILDING GROUNDING Q .7 � U ELECTRODE cc N LLI �O LL (� Z 0O O LU Cn Er 0 Circuit# PV Module Oty. Micro-inverter oty. Maximum AC Operating Current un 0 c 1 REC420AA Pure 2 11 Enphase 108A-72-2-US 11 15.95 A a m 2 REC420AA Pure 2 11 Enphase 108A-72-2-US 11 15.95 A o co 3 REC420AA Pure 2 8 Enphase 108A-72-2-US 8 11.6 A 00 4 REC420AA Pure 2 7 Enphase 108A-72-2-US 7 10.15 A T Maximum AC Operating Current(Total) 53.65 A Elml ONE-LINE DIAGRAM • I, LABEL LOCATION: LABEL LOCATION: MAXIMUM AC•• SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Service — MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE Q- NOMINALDISCONNECT IF APPLICABLE.CURRENT VALUES ON DISCONNECT LABEL. a, Nt • .ti NEC 2017 690.54/NEC 2017 690.13(B) NEC 2017 705.10 '' Second Disconnect WARNI �• next to Meter Pan ELECTRIC SHOCK HAZARD NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO DO NOT TOUCH TERMINALS THE BUILDING MAIN SERVICE DISCONNECT. TERMINALS ON BOTH THE LINE AND Primary Service Disconnect LOAD SIDES MAY BE ENERGIZED This building is equipped with an IN THE OPEN POSITION Located Interconnected Electric Power SUNATION PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE Production Source WHENEVER THEY ARE EXPOED TO SUNLIGHT DO NOT • SUNation Solar Systems Source Type. 171 Remington Blvd. Ronkonkoma,New York 11779 Solar Photovoltaic (631)-750-9454 Disconnect is Located Intenoc Basement. Garage:_ Exterior:— S 4355 Front Rear:_ LH Side INSTALLER STALLEALLE R RH Side- Other Location: NUMBER SUNation Solar Systems SOLAR SYSTEM EQUIPPED JOB NUMBER 631-750-9454 WITH RAPID SHUTDOWN www.sunation.ccm TURN RAPID SHUTDOWN 24146 SWITCH TO THE PH • • •LTAC "OFF"POSITION TO SHUTDOWN PV SYSTEM EQUIPPED WITH WID AND REDUCE THE SHOCK HAZARD SHUTDOWN IN ARRAY 0) M T V IV CD Z CV T O C:) rZ LO ZO U Cz O c LU Z O O O LU N 0 C O a m >+ Cz O CIS O T E2=1 PV LABELS • ,`P 0�m G, 1. �D y - A 746 l SUNATION SUNation Solar Systems ey 171 Remington Blvd. ■ 5. Ronkonkoma,New York 11779 (631)-750-9454 '� ,• • {2 NYSERD IN INSTALLEALLE R NUMBER 4355, j JOB NUMBER • 2414 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA DRONE rn co _rn r Ct } N Rey Z N a \ - l c� T ,. O1^ ZO a) ca O � 2 r r` Q) cz - m w y O U. fl ca c CZ c co } '"1"i* _ + . ' co '•+ ..R ac .tram wig.^..l.W°tl .. ..R SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP GI A PVPHOTOS