Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51484-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51484 Date: 12/17/2024 Permission is hereby granted to: Elizabeth Rerisi 29 Whitman Ave Syosset, NY 11791 To: construct single-family dwelling as applied for per DEC Non-Jurisdiction letter,SCHD&Trustees approvals. Premises Located at: 3085 Laurel Ave, Southold, NY 11971 SCTM# 55.-3-31 Pursuant to application dated 10/11/2024 and approved by the Building Inspector. To expire on 12/17/2026. Contractors: Required Inspections: Fees: Single Family Dwelling-NEW $2,628.75 CO-RESIDENTIAL $100.00 Total $2,728.75 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 x Telephone(631) 765-1802 Fax(631) 765-9502 h s:Jlwww.southojdtgAl �. oar Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only x I PERMIT NO. - Building Inspectors I• 0 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2).shall be completed. Date: /0 0,.2 OWNER(S)OF PROPERTY: Name:Elizabeth Rerisi and Samuel Fishman I SCTM#s000-55-03-31 Project Address:3085 Laurel Ave. Southold Phone#:516 375-5872 =:vrerisi@gmaiI.commail Mailing Address:P.O. Box 507, East Marion, NY 11939 CONTACT PERSON: Name:Gail Rerisi. Attorney Mailing Address:P.O. Box 507 East Marion, NY 11939 Phone#:516-939-0669 Email:grerisi@gmaii.com DESIGN PROFESSIONAL INFORMATION: Name:Robert James Higgins, Architect Mailing Address:50 Hidden Acres Path, Wading River, NY 11792 Phone#:631-208-3351 Email:Rarchibob@aol.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION RNew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other d c o0, Will the lot be re-graded? ❑Yes 'NNo Will excess fill be removed from premises? WYes ❑No 1 PROPERTY INFORMATION f r e Existing use of property. Intended use o pop rty.1 Family Residence Vacant v Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes RNo IF YES, PROVIDE A COPY. ❑Check Box After Reading: The / / professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPUCATION IS HEREBY MADE to the Building Department for the Issuance of a;Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffok County,New York and other apppeable laws,Ordinances or:Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein descrMed.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and In budding(s)for necessary inspections.False statements made herein are punishable as a Gass A misdemeanor pursuant to Section 2WAS of the New York State Penal law. A Elizabeth Redsi Samuel Fishmal� Application Submitted B rant name): G]Authorixed Agent 'Owner PP YIP Signature of Applicant: ate: d✓^ "`Del STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Elizabeth Rerisi and Samuel Fishman being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Owners (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this d_6A,<A_A-- �0 24 day of � i �y '� 20 N(tary Public GAIL A. RMS1 NOTARY I'tptIC,STAfE OF NEW YORK PROPERTY OWNER AUTHORIZATION NM O,2RE4960926 Oualifled in Suffolk Counfy (Where the applicant is not the owner) OY Commission Expires January 02. 207r- Z(0 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 r t ,, ��/(Frra/iyir d�Rrlf,.,,w w ;z.ai, � r r,l ,nd^ v,'.,ii .,, p F�'" wl�'�i✓�I;(�'wRd�Cp�&ufG�drr�q A fIG"u�l�!�tuwrl ,1fEul ,� GIr KiCI�, i 'r r, p �� , %p�,�( Ir is ✓Yw,l; G����Gir I i!�Glv,, rran,nh, 'l"r/ rfGG yUi% a4 a ��y t�!�r G � I I ;�rti ,° /rrr%, of a �'GNru^ � ;J+j,�iR r' �� ' � -, � t��^,,kr �,� � � r��,brYrr,r��,;� r 'It,�t�r �' r. "` d� �'r � ;% � '� k ,er r •�� r�41 ,i,r ✓^ �,nw,, �i���,,,r.�vl,,�r GI.Ui 4 � � �r �� .r ra �6, r- r o r, >� ,^riryrviurriurnr�rn onni,rr�r 1r,,nnw ra ri,J,,, 1U", r,.,rrm ri i.,,iiro,r�va,r„r7�ii r;��rc ri„var�srr/Oloirii, „r�i oaar ji r,;,rira �,nevi.:,r„rr„ rr,nJri,rin,,, lrNalt!.,nrli'",or, »r yiw5i�o+�iniirryrxihrr ,�. BOARD OF SOUTHOLD TOWN TRUSTEES ' SOUTHOLD,NEW YORK �� �� PERMIT NO. 10649 DATE: SEPTEhIIER 18,2024 ISSUED TO: ELIZABETH RERISI&SAMUEL FISHMAN i '! PROPERTY-ADDRESS: 3085 LAUREL AVENUE2 SOUTHOL SCTM#1000-55-3-31 ' `rr AUTHORIZATION fa r Pursuant to the provisions of Chapter 275 of the Town Code of the Town of Southold and in accordance with the Resolution of the Board of Trustees adopted at the meeting held on SSpptember 1 S,202 , 1 i r r 1 and in consideration of application fee in the sum of�a0 paid by Elizabeth Rcrisi SSwnuel Fishman and Termsno subject to the and Conditions as stated in the Resolution,the Southold Town Board of Trustees authorizes and permits the following. Wetland Permit to construct a two-story,2,878sq.ft. dwelling with entry porch,rear porch,side entry,basement entry and attached garage; install A/C units and generator; ° install an I/A OWTS system landward of dwelling;install a permeable driveway; install Job' gutters to leaders to drywells to contain roof runoff; establish and perpetually maintains ' r a 25 foot wide Non-Disturbance Buffer area along the landward edge of the top of the bank with a four(4)foot wide access path to the water;with the condition to establish N � and perpetually maintain a 50'wide non-disturbance buffer along the landward edge of the wetlands; all as depicted on the site plan prepared by Nathan Taft Corwin III, U p� P p p Y Land Surveyor,received on September 30,2024,and stamped approved on October 4, 2024. IN WITNESS WHEREOF,the said Board of Trustees hereby.causes its Corporate Seal to be affixed, and these presents to be subscribed by a majority of the said Board as of the day and year written above. ° r r u,,. „r l�".w vu✓rig 4nrerrrr,r�;do,,�niW�;roi7iairtG�„nt„/r11 tiF r,.�rrPi N r „n. nrr rnrr rY�k..u/rr�rw trr,.,w.. r r r �u�l. al •.., / 01 r.. ! �,:� r.,, d o „- /, .. �,,d. "" ,�� ,"f ! l:UG l� w °ti."I�i� h�';,, ✓�u(N�e,, „.�" „rONN+�'' ,ti �"� ";y^� � �^�„ „rri i�v.�'",, rl ,�r(-° rI q `:'",.w l "; / �`'�"r�)VY Ul i�= U til°R �i" a= 1')II��,�", r° r � f „.,. ��, „ ri�lar�l,2,i,^,r r)il G,,;. r2lGm�rif✓rtr r fry.�' iN, � di, v,,,.,'Y�, rr�^�, "n, �,�'�,r,„✓rrr�r,^r„ 11 a�?iifiu,.r9�z^�iJ -o �NiGI��N�yulI,UY)P,�"lr�",'�1i'ix" r, fJ � �" ,9k, a �r"u �nrrr �'i �'''R"➢n� �"�;n� ,"an"�nii����� ','�' � �' r,..;.;;,,w r„"fie' �`p�.��, ! � f,..rl ,ir ;�,.,.,m r,ii� 1..� im Yl!'ia4��' �rti�;, r1'�:! LONG CREEK APPROv'D BY BOARD OF IrtUSTEES N 89'48 44" E 60.78' TOWN OF SOUTH OLD SURVEY OF MIROPERTY N I�.3 •39-- E SITUATE 4t.08} DATE O �e�CCD 11 �0)A SITUATE TOWN OF SOUTHOLD S UFFOLK COUNTY NEW YORK a _ w � —as S.C. TAX No. 1000-56-03-31 SCALE 1"=20' MARCH 25,2024 a r Z@£.L A MAY 22,2024 EA PROPOSED HOUSE w JUNE 20,2E4 REVISED PROPOSED ROUSE SEPTEMBEE S,2024 REVISED W ADD ADDITIONAL K TO T STRUCTURE DIMENSIONS � � �•; i ��� ^ /l�rf a � `;� � SEPTEMBER 77,2024 ADDED TOP OF BANK TO THE EAST r a---' ) Z px FRM�ROUSE TOTAL TIE E) 0.454 5 c. ft. 7 • [[ sf > .. BUILDABLE LAND AREA = 18.475 asq. ff. o S 1 sta Or t �r> ..o� ,'� a �{ .I Al, � � @ CERTIFIED TO. s-- - £ i '4 ELIZABETH RERISI ' >j``` _ '� + t s= L 3 SAMUEL FISHMAN FIDELITY NATIONAL TITLE INSURANCE COMPANY TITLE No. SP49996-S SPANO ABSTRACT SERVICE Corp. t NOTES; ` \ � sit 1. ELEVATIONS ARE REFERENCED TO N.A.V.D. 198E DATUM EXISTING ELEVATIONS ARE SHOWN THUS:xxx l EXISTING CONTOUR LINES ARE SHOWN THUS: xx————xx i 2�oAx µE NOSE ToP iVJOR lw TOP(IF WALL , 2. FLOOD ZONE INFORMATION TAKEN FROM: ` FLOOD INSURANCE RATE MAP No. 36103CO15BH T ZONE AE: BASE FLOOD ELEVATIONS DETERMINED ZONE X: AREAS DETERMINED TO BE OUTSIDE THE 0.2%ANNUAL CHANCE FLOODPLAIN. 3. PROPOSED SEPTIC SYSTEM: PROPOSED EXPANSION POOL PROPOSED LEACHING POOL PROPOSED OWTS TANK ' y§�.� -- � �u � // ® PROPOSED 12"x12" POLYLOK DISTRIBUTION BOX a _ LOT COVERAGE OVER BUILDABLE LAND AREA DESCRIPTION AREA X LOT COVERAGE` 2,488 sq.0. 13.5X PORCHES -- 385 sq. ft. 2.1X TOTAL 2.573 aq.lit. 15.6% IPA ao g ro T. Ma—s— SEP 3 0 2024 s ---. - Txe oxsaxee m wart m To.1 1 aN0 OR HATFIIIXR OP Ia G IF DRAINAGE SYSTEM CALCULATIONS: exf xm sxam axe xm euePnrrtFEo ROOF AREA: 2,t.X 600 sq.0.17 ft. 2,600 sq, f = 442 cu. ft. '. Nathan 1 T aft Corwin ��� sE- 442 cu. ft. /42.2 = 10.5 vertical ft. of B' dla. leaching pool required -r,. Land Surveyor PROVIDE(2) B' dla. X 6' high STORM DRAIN POOLS60 f{; ,2 -. Succmar To:Slanly J. L5.0 PROPOSED 8' DIA. X 6' DEEP DRYWELLS FOR ROOF RUN-OFF ARE SHOWN THUS zs Etr - >m.sw.y,-s mA;fiwu-srt.Pbru-ax,wraa,mTxul PHONEt)-727a zosD F.(631)m-1727 P.O.m+to t+f tl S aa4 Jo„"a Nw Yx�11.7 JmwrpxrE Hn Yo,h 17xtT i MAP OF YENNECOTT PARK E N 89 46 44' E 60.78' a 14 SITUATE N " SITUATE AT THE TOWN OF SOUTHOLD 7 i O FILED MAP#5187TOAN OF SOUTHOLD mom_ BUFF OLX COUNTY.NY. rl z LOCATION MAP N.T S - ( 1 1 AfaMEYFMs O ,• .� •.. ' •xI =;\ b rrR MWMKDMdWlr p +.F. J '. z-. � PROJECT DATA -. o l 77[[ - ' i , a --a +r. ararua/aalm usTBO%wlaalT , "- 9 a . �t � WP MNill mf D]9lOCY 0] Lt /I Q 312 Y1PA �� _ I� .. axac ri.w.IeroExcc I NO SURFACE RATER HIIHIN TS`TO PROPOSED SEPnC TANK NE NOOSE F - =. r NO SURFACE WATER U-S 150'TO PROPOSED LXHING POOLS. l ERA - \ I Tr£ _ NO PRNAIE WATM WE115 AIIE LDG1E0 WHIN LSD'OF THE f'gOP0aE0 - \ _ �{� SANRARY SYSTEM NO PUBLIC WATER WELLS AIIE WOHW 200'OF THE L K.IWAPAN 3 D P C 9 Ta I!' L PROPOSED""M SSTEN - J NO DR/JNAGE SIRIICNRES XRHIN 10'Or WIRMY SYSIFM } PROPOSED DWDUNG INCLUDES 3 BEOROONS PROPOSED SANnARY SYSTEY IS DESIGNED E OR A ELEVATION R 11 NAXIIAU •BEDROOMS k T ii—EN SMALL CONSIST OF FUJI CLEAN CENS SEPTM TANK, DLSTRIBUTION BOX ANC(])B'YXB'DEEP LEACHING POOLS. - PROJECT, ✓L E. HOLE TOWN OF SOUTHOLD - SUFFOLK COUNTY, NY SINGLE FAMILY RESIDENCE l _ ( j elan nn.b saw i 3065 LAUREL AN. —TES r iviie sw eounwm w non F W ?x r _: nUO L4 21. c3=€ TsA ( T AOWTI --- -_.. a , .✓n f � a ��R VE RAPPRO � I CES SEE rl.TTACIIVENT"S'� E F L0NG �Fl I l ,`= FM�L m-ENCE ONL Y DRAWING TITLE: ----. -.--- A; R- 4-0 SANITARY PLAN o SITE PLAN IFOR MAXIMUNI OF A 4 SCALE:1'-30' _ _ S� I T YEAR'S�W DATIE OF APPROVAL % S 1 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES  at 34F A ES€sY P1RE1 f UA AL€ - PNL PIPE KR YTA E PoLS LIIVFA WIIN PROMSED UG. �D^ TO M INNE -POLYILK S�FEIY eCxfD! y§CAl>$w f EE HARED 1.TO ,Vfl aLOWFT PPNET CONNELININ ttl `FyE�� AS PFA YAxUFIL1UREAS (1TP GOR pLL Sj r BE NNiDMREO lO CONIROELER AS PEA SCDlIS• I REOIWIENFNni f #r. YWIUGACNAFPS REWIREYENR.(SEE e]) }J'A(x•Wn)NDPE 1 w/CHwit0A1 nL1FR Ie' IN AROVE u"uc x'RICH.FHOM ANY wxoow OR DOOR. ( MIN,4"DIA, POLYLOK 20•COVER SDR 35 PVC Pe5C 14 - EL 17.00 PIH MIN N PPR EJ.BO j[ t - aul�'Rni'�'o-rts�iuRm's =r`�RISERS K 6" n SItlMYP OR END PWC_- ' POLYLOK 20" DISTRIBUTION BOX P TYPE ENOLEVELING DEVICE - -. LOCATION MAP +' P. �' OF NC i MIN,4"DIA. N.T.S PIPE a I•PER.,e -e�'PER GODT YN-IxD d t I SDR 35 PVC PIPE PITCHED t..to ----�� ul"Ixv..l].el T —MIN,1/B'PER 1' $[ �� s� PROJECT DATA IM �aM PK PeNEIIV.TE ` INV,=1J.6J =aWHDAnON WA11 YN x' IPPUfMA/ T�' MIN. 12'COMPACTED SANG OR FAsr®"weon.Nr Hxxx ' PnoPOeeD 9 1 3 ! 2•MIN - PEP GRAVEL LEVELING Ppfl �R OUTLET ( I DISTRIBUTION/SAMPLING MANHOLE MAIN HOSE BUILDING CONNECTION-DETAIL AIL I/A OWTS FUJI CLEAN CEN5 500 GPD N.TS :-K-N fA1d_ 'EEB:OPA CONCRETE COVER BELOW GRADE d= 2`MAX. 6"THICK SLAB PRWECr 4 DIP, THICK OF SOUTHOLD SOR 35"f T Tg;. . MIN --- - .}.47 I/Aox O.W.T.S NOTES: SUFFOLK COUNTY, NY aNULsrsra rroi vomm.eu tD ue^wl ox-srt�e.w.YflNw.vPRmm _ __-_. g v ra uuuc€cmREA mEG« ems . SINGLE FAMILY RESIDENCE A�.�nttP�N]RaR.o< sET,NE NF A DR Dwra PP.PN�Axa oKx Y:n(.xD7Dfl ssaRE NDRnI uw swu w4]uuaE Arc• seumDln,xr Itx7t " m-'R'�� nfl C0H1P1LfO^10 ISSUES/REVISIONS ° 0--0 4"D11OV y': ¢s :" -=' ucDD m DescriPUon --... 1 No. ODte PVC CROSSOVER PIPE _ �xo�asacv.O C0115'IR Nw wu:"r`�'xTt Fm s�.°1�` "onPo°fsu°Nsm"i0N1a's°1ioORR o awurc awtwnm Fa PPmv.' � � mwR-N.x s.�E PYn.WSDDnGA e.TT wL.x mRo _- _ _ , ,.a onsnE P.stEwAroe namYexr smEY wnsl Ysru.Ew uwc Nain R=PIunP.a DtDa�FYntrs 3 moR arGaR mwn ovunuun or�ri�N mmccs.No Yuu<.n wemrcanN�.uaR -_-. 3P• ( i!I I '"miw,�.a`Nr.'efPi,N wu Rc mm '€ I. 3 ETF. € I "troinn aWDiwui eT nD.rom o s:.Pwv N ,n .wo ra Ji DEPTH J 0 €€ ,YL DlCNCFJI lM]IIm11 wAN10 m / !.s ttMN10. I e !`� j � I I n YNnFu:Nn0.PT 4L Y€PA •YNW W tllAl €•UXLLS OflG,FA CmFA 5 REOUIiED BOTTOM OF [ I �:€u roY,R.noxs xm>K a.to wu s rHm um rrtA tlaP_ El. PDOL7.BJ 3 6'MIN,.PENETRATION I --- i I INTO A VIRGIN STRATA OF SAND k GRAVEL rE v A-I TA I P 3 US DRAWING TILE SANITARY DETAILS 1 }`MW -96VE HIGHEST BACKFILL ; GTeiT MATERIAL CLAN SAND AND GRAVEL - n HIGHEST EXPECTED WATER ELEV.=4.6' _ 3, _ S i22 TYPICAL LEACHING POOL DETAIL 5 N.T S a SY+E 3a S2 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES a $ n= PIE Ilk * � r r•§ Mgt —_ „>a HOW LOCION MAP _ I 4 x s .r aP W EN ATNSS, '-di -Af U AC-ar e- + -- _ PROJECT TA a v� 3 � PLnNVIEW TYPICAL CLEANOUT DETAIrNNL N.T.S „�.Man xuuoa .vu oa mnc.vz e - BEACON SYSTEM ONTROLLER/ALAR _ e 3 [ - M E}C_. (FASTEN TO BUILDING) [ #-��`� C 511E CML ENGINEER FAS1E NC) €L LK&A ELECTRICAL&CONTROL TO BLOWER L K. -. TOB D P C. coNmoL wlRmc I Owrs jBLOWER TO BE DWIREDT NAR 0 CONTROL PANEL TO I ELECTRICAL SECTION A-A VIEW SI-CTION D B VIEW SUPPLY �? (� � �COMPRESSED AIR LINE TO OWTS nG,n,n ono., I f ...,.�..m CF.RECEPTACLE -'' _.,• YOUNUIL ON--- ` ( 3 { �- 'Fi3 Bib ,w.r... - BUILDINC ©LR.YcLFN1 ASSGCUT6.GP.C. 117 1 iY —E'CONCRETE BLOWER PAO PROJECT' TOWN OF SOUTHOLD f SUFFOLK COUNTY, NY SINGLE FAMILY _®� CONTROL PANEL & BLOWER DETAIL N RESIDENCE .wm LWREL Arc, swnro�u,xv,Ivri 3 Jf 1 (§ H M FEE N ORAWNc mE:ARY SANTI DETAILS 2 _ PROPOSED TUF-TITS ?A' SAFETYI in N.T.Sr FUJI"C d --- a SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES S3 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division of Environmental Permits,Region 1 SUNY a Stony Brook,50 Garde Road,Stony Brook.NY M790 P:(631)444-03651 F:(631)44"360 www.dec.nygov LETTER OF NO JURISDICTION: TIDAL WETLANDS ACT& NOTIFICATION OF POSSIBLE ENDANGERED SPECIES ACT JURISDICTION July 17, 2024 Elizabeth Rerisi Samuel Fishman 29 Whitman Ave. Syosset, NY 11791 Re: DEC# 1-4738-05019/00001 Rerisi/Fishman Property: 3085 Laurel Avenue SCTM# 1000-55-3-31 Dear Applicants: Based on the information you submitted the Department of Environmental Conservation has determined that the portion of the subject property landward of the line labeled "top of bank", as shown on the survey prepared by Nathan Taft Corwin III, last revised 6122/2024, is beyond the jurisdiction of Article 2E (Tidal 'Wetlands). Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (BNYCRR Part 661) no permit is required under the Tidal Wetlands Act. Please be advised, however, that no construction, sedimentation, or disturbance of any bind may tape place seaward of the tidal wetlands jurisdictional boundary, as indicated above,without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project(i.e. a 15,to 20'wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be advised that DEC has documented the summer occurrence of the Northern Long Eared Bat(NLEB) (Myofis septentriN`onall/s), a species listed as "endangered" by both New York State and the US Fish &Wildlife Service, within 3 miles of the project location. We have determined that tree cutting at this location between March 1 and • " result(n the"ta ke"of these endangered/threatened November 30 of any calendar year may species or their habitat within the meaning of Environmental Conservation Law(ECL)§11-535. The term "tape"is defined in part as the direct killing or injury of individual members of a protected species, interference with critical breeding, foraging, migratory or ether essential behaviors, or the adverse modification of the species' habitat. The"take" of a species listed as endangered or threatened is prohibited in the absence of a permit from this Department issued - �ibe mm wro �nt�r consemion -5 In order to avoid an Endangered Species ""take," no tree cutting pursuant to EDL 11 35. g P'� P § activities may be conducted at the project site between the dates of March 7 and November 30 of any calendar year. If you have questions about the presence of protected species on or gear your property, the potential effects of activities on these species or your responsibilities as a landowner or project sponsor under the Endangered Species Regulations, please contact time Regional Wildlife Manager at(531)444-031 i. This letter shall remain valid unless site conditions change. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincerely, E ssa Scott Permit Administrator cc: D_ Bergen BMHP Wildlife file Town Hall Annexe �� Telephone(631)765-1802 54375 Main Road y d Fax(631)765-9502 P.O. Box 1179 l Southold, NY 11971-0959 �4 J° BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE CONSTRUCTION PRE-ENGINEERED WOOD CONSTRUCTION ANDI'OR TIMBER CONSTRUCTION Date: 16 � Owner: Location of Property: .... ,v �..�6. � . ZID Please take notice that the (check applicable line): V New commercial or residential structure Addition to existing commercial or residential structure Rehabilitation to an existing commercial or residential structure to be constructed or performed at the subject property reference above will utilize (check applicable line): Truss type construction (TT) - .. Pre-engineered wood construction (PW) Timber construction (TC) in the follo ing location(s) (check applicable line): Floor framing, including girders and beams (F) w. , Roof framing (R) Floor and roof framing (FR) Signature: Name (person submitting this form): Capacity eck applicable line): k" Owner ....� Owner representative TrussReg15.docx Effective 1/1/2015 Generated by REScheck-Web Software Compliance Certificate Project Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY 11971 Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 2,826 ft2 Glazing Area 16% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: 3085 Laurel Ave Elizabeth Rerisi&Samuel Fishman Robert James Higgins Architect Southold, New York 11971 Residence i Compliance: 6.3%Better Than Code Maximum UA: 477 Your UA: 447 Maximum SHGC: 0.40 Your SHGC: 0.30 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. SUab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in RESc:heck, Each slab-on-grade assembly in the specified climate Bone Whist meet the minirnum energy rode insulation It-vMue and depth requirements. Prop.Envelope AssQ_mblies Gross�Area Ca vity Cont. Prop. Req. Perimeter Ceiling: Flat Ceiling or Scissor Truss 1,772 30.0 0.0 0.035 0.026 62 46 Flat Ceiling: Flat Ceiling or Scissor Truss 273 30.0 0.0 0.035 0.026 10 7 Exterior Walls: Wood Frame, 16"o.c. 2,319 21.0 0.0 0.057 0.060 102 107 Front Door: Solid Door(under 50%glazing) 28 0.200 0.320 6 9 Side Door: Solid Door(under 50%glazing) 25 0.200 0.320 5 8 Windows:Vinyl Frame 485 0.300 0.320 145 155 SHGC: 0.30 Staircase: Wood Frame, 16" D.C. 220 13.0 0.0 0.082 0.060 18 13 Garage Walls: Wood Frame, 16" D.C. 279 21.0 0.0 0.057 0.060 15 16 Garage Door: Solid Door(under 50%glazing) 19 0.160 0.320 3 6 Project Title: Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 1 of10 Data filename: p Gross Area Assembly or 'Cavity Cont� Prop. Req. Prop. Req. Attic Wall: Wood Frame, 16" o.c. 232 21.0 0.0 0.057 0.060 13 14 Floor Over Basement: All-Wood JoistfFruss 1,996 30.0 0.0 0.033 0.047 66 94 Floor Over Exterior: All-Wood JoistfFruss 30 30.0 0.0 0.033 0.047 1 1 Floor Over Garage: All-Wood Joist/Truss 17 30.0 0.0 0.033 0.047 1 1 Compliance Statement, The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Michael Fauci - HERS Rater 06-24-2024 Name-Title Signature Date Project Title: Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 2 of10 Data filename: 9 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. LSectio�niPlans Verified Field Verified # Pre-Inspection/Plan Review Value' Value Complies? Comments/Assumptions Re _ 103. documentation demonstrate �. VCoes Not Re 103.1, ,Construction drawings and p Requirement will b q.�..._._� e met. [PR1]1 energy code compliance for the ❑Not Observable !building envelope.Thermal envelope represented on ❑Not Applicable :construction documents. �` �.ew.w . _ .. ........ ........ 103.1, Construction drawings and ®Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable 'Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. ............ ...... _ ... _ _.�.;. ....... 302.1, Heating and cooling equipment is Heating: Heating: ®Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr60K Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr33.8K „Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: ......... 1 High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 CLow Impact(Tier 3) Project Title: Elizabeth Rerisi &Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 3 of10 Data filename: section Foundation Inspection Complies? Comments/Assumptions & RI _. .. ...._. _....._..w _.., ._—...... ... .... ...._.. ._._w __. _...._. 3012.1 'A protective covering is installed to ®Complies Requirement will be met. jF1 )� 'protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ❑Not Observable l grade. ❑Not Applicable _ 40Minstalled. ❑DoNot Exception: Requirement is not applicable. 403 9 Snow-and ice-melting system controls mp es r :[]Not Observable ONot Applicable j Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 M di eum I mpact(Tier 2) � 3 Low Impact(Tier 3) ..._ ... Project Title: Elizabeth Rerisi &Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 4 of10 Data filename: Section Plans ValueVerified Y Field Value fie 9InspectionM - ents/Assumptions 9 p o.�s Lcomplies? Comm 402.1.1, Doom'nfactor, U- U I�COm # /Rou h In Ins ection & Re ID _ U- plies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U-0,30 U_ ®Co 402.3.1, average). []Do plies See the Envelope Assemblies es Not table for values. 402.3.3, ❑ e Not Observable 402.5 ' 402.5 ❑Not Applicable U, 303.1.3 e are fenestrationd in ducts mm _ ❑DoespNot Requirement will be met.q with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable - 402.4.1.1 ;Air barrier and thermal barrier ®Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. '❑Not Observable " o ❑Not Applicable 402.4.3 Fenestration that is not site built ' �, ®Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not 'AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC rated recessed lighting fixtures ®Complies Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate :52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable ...... 403.3.1 Supply and return ducts in attics ®Complies Requirement will be met. [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where < 3 inches.Supply and return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 ,for< 3 inches in diameter. __. ........ ........_ 403.3.2 Ducts, air handlers and filter ®Complies Requirement will be met. [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with ❑Not Observable International Mechanical Code or International Residential Code, as ❑Not Applicable applicable, ........-. 403.3.5 Building cavities are not used as ®Complies Requirement will be met. [FR15]3 ducts or plenums. , ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R � 3 ---�R Complies Requirement will be met. [FR17]2 above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- ❑Not Observable3. , ❑Not Applicable 403.4.1 ,Protection of insulation on HVAC 7 QlCornplies Requirement will be met. [FR24]1 piping. '❑Does Not '[-]Not Observable ❑Not Applicable 40 j5.3 Hot water pipes are insulated to R- R OComplies Requirement will be meta [FR8]2 >_R-3. ❑Does Not []Not Observable ❑Not Applicable Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 High Impact(Tier 1) 2 �J� ry Project Title: Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 5 of10 Data filename: F section Playas verified Field verified Re Framing/Rough-on Ins pectlan complies? Comments/AssumptionsQ 61 Automatic or gravity dampers are.m w, ValaeWµ value [Zcomplies Requirement will be met. (FP19)2 installed on all outdoor air 0Does Not intakes and exhausts. []Not Observable ©Not Applicable Additional Comments/Assumptions: ��_.�. ........ 1 Nigh�lmpact iTier 1) 2 Medium impact IlierLow Impact iT'ier 3) Project Title: Elizabeth Rerisi &Samuel Fishman Residence- 8085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 6 of10 Data filename: section Plans Verified Field Verified Inspection �. �. .m..,. Complies? e�Comments/Assumptions met. # In installed insulation islabeled Value Value Complies� les? Requirement will Insulation 303.1 [IN13] orlthetnstalled &Re ID et. 2 R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable ._ 40. 3. 2.1.1, Floor insulation R-value. R- 0 R ;®Complies see the Envelope Assemblies 402.2.6 ;® Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, :Floor insulation installed per ' ®Complies Requirement will be met. 402.2.8 :manufacturer's instructions and ❑Does Not [I1\12]1 :in substantial contact with the ❑Not Observable underside of the subfloor, or floor :framing cavity insulation is in ❑Not Applicable contact with the top side of :sheathing, or continuous insulation is installed on the underside of floor framing and :extends from the bottom to the .top of all perimeter floor framing members. _ _ 402.1.11 Wall insulation R-value.lIf this is a R Wood .❑R Wood �m P omplies table See the Envelope Assemblies 402.2.5, mass wall with at least /2 of the ❑Does Not for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [I1\13]1 exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per Complies Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 7 of10 Data filename: Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID _ 402 1.1, Ceilinginsulation R-value. R ...... � � R_._._...� gC._- ies ..m...v..l .� •n � 30 omplies ,See the Envelope Assemblies ® Wood ❑ Wood oes Not table for values. 402.2.2, ❑ Steel ;❑ Steel ❑Not Observable 402.2.E[Fill' ❑Not Applicable 303.2 'Ceilin insulation instructions.installed per OComplies Requirement will be met. 303.1.11, g ' p manu es Not [F1211 Blown insulation marked every -300 ft2. ❑Not Observable ❑Not Applicable 402 23Vented attics with air permeable _.- � ®Complies Requirement will be met. [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402 2.4 Attic access hatch and door R-30 R ®Complies Requirement will be met. [FI3]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable :❑Not. Applicable ......._ .._... __......�.m..�...-.�.�.-. � 402.4.1.2 'Blower door test @ 50 Pa. <=5 ACH 50 = ; ACH 50 ❑Complies Requirement will be met, [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ..... .m. ..... ®Not Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Requirement will be met. [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ®Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total i leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. ........ - ... ........................ _.� 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies .Requirement will be met. [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ®Not Applicable occur during Framing Inspection, 403.3.2.1 Air handler leakage designated ®Complies Requirement will be met. [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats � -"� - n• ®Complies Requirement will be met. [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. ❑Not Applicable .v 4 .......... .... p 403.1.2 Heat pump thermostat installed ❑Com lies Exception: Requirement is [Fl10]2 on heat pumps. ❑Does Not not applicable. ❑Not Observable ®Not Applicable 03.5.1 Circulating service hot water ®Complies Requirement will be met. [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 ,High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 8 of10 Data filename: section Plans Verified Field Verified Provisions Value Complies? Comments/Assumptions �403.6 All mechanical ventila Final InspectionValue .... ........ tion system VComplies Requirement will be met. [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable and airflow limits per Table R403.6.1. ❑Not Applicable � i e � e .ElD.� - 403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is [FI26] :through or two- heating g p p g oes Not not applicable. systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ®Not Applicable temperature. �.. - _ .......... .-.......................-........ 403.5.1.1 Heated water circulation systems ` ®Complies Requirement will be met. [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply, pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are •; not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. ..m.. 403 _.._ 5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is [F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 515. Controls automatically adjust the energy input to the ❑Not Observable 'heat tracing to maintain the ®Not Applicable desired water temperature in the piping. 03.5.2 Demand recirculation water ®Complies Requirement will be met. [FI30]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water ❑Not Applicable piping to <= 1049F. 3.5.4 Drain water heat recovery units „ ❑Complies Exception: Requirement is [FI31]2 tested in accordance with CSA ❑Does Not not applicable. B55.1. Potable water-side ❑Not Observable pressure loss of drain water heat recovery units< 3 psi for ®Not Applicable individual units connected to one ;% or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. _ 404. fixtures have high permanent lamps. � ❑Doe 404.1 90/o or more of permanent ®Complies .Requirement will be met. 1 g y p s Not ❑Not Observable ❑Not Applicable k404.1.1 Fuel gas lighting systems have gComplies Requirement will be met. [F123]3 'no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable ... 401.3 Compliance certificate posted„ ®Complies Requirement will be met. [FI7]2 �� ❑Does Not ❑Not Observable ❑Not Applicable ... ............ 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) .wwwww _ wn www__ Project Title: Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/24 11971 Page 9 of10 Data filename: Section Mans Verified Field "erified' Final inspection Provisions l�altr� "iPalue omplies? comments/Assumptions la�ec�li:9 _ fi3.3 .. anufacturer m'ECorn lies Requirement manuals for p q ii met. (FI181s mechanical and water heating ®Does Not systems have been provided. nNot observable EI Not Applicable Additional Comments/Assumptions: ....._ p pet(Tier ) 3 Craw lmpact(bier 3) 1 ill i —Impact i i'er1} l edM. It pact Project Title. Elizabeth Rerisi & Samuel Fishman Residence- 3085 Laurel Ave, Southold, NY Report date: 06/24/ 4 11971 Page 10 of'lo Data Men' me; C2018 IECC y �(j EffidencyCertificate Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 30.00 Ductwork (unconditioned spaces): Window 0.30 0.30 Door 0.20 • . . Heating System: Cooling System: Water Heater: Name: Date: Comments