Loading...
HomeMy WebLinkAbout50599-Z SUFFUIkc Town of Southold o�y 9/10/2024 P.O.Box 1179 0 co IM z 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45536 Date: 9/10/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 565 Old Main Rd,Laurel SCTM#: 473889 Sec/Block/Lot: 122.-7-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/20/2024 pursuant to which Building Permit No. 50599 dated 4/26/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Fliss,Janice of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50599 8/28/2024 PLUMBERS CERTIFICATION DATED i A h riz ignature gOFF04 TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50599 Date: 4/26/2024 Permission is hereby granted to: Fliss, Janice 565 Old Main Rd Mattituck, NY 11952 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 565 Old Main Rd, Laurel SCTM #473889 Sec/Block/Lot# 122.-7-2 Pursuant to application dated 3/20/2024 and approved by the Building Inspector. To expire on 10/2612025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector oF so�ryol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 ��1�� 0 �� sean.devlin(aD-town.southold.ny:us om BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Janice Fliss Address: 565 Old Main Rd city:Laurel st: NY zip: 11948 Building Permit#: 50599 Section: 122 Block: 7 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunrun Installation License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 6.8kW Roof Mounted PV Solar Energy System w/ (17)Hanwha QcellgpeakDuo ML- G10+T400 Modules, SE6000H-Uss3 6000W Inverter, 35A Fused Disconnect, Lineside Tapped Notes: Solar Inspector Signature: Date: August 28, 2024 S.Devlin-Cert Electrical Compliance Form Copy SOUTyO� # # TOWN OF SOUTHOLD- BUILDING DEPT. coo 631-765-1802 -- 1/ NSPECTION 4,�j . [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [. ] ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 5 D li4-V" [ ] FIREPLACE & CHIMNEY" [ ] FIRE SAFETY INSPECTION .[ ] 'FIRE RESISTANT CONSTRUCTION [ . ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 63) VtCl� DATE 8� INSPECTOR hO�aOF SOUTyOIo ��c./ ( �,✓� v �� ��/.1� * # TOWN 01�-SOUTHOLD- BUILDING DEPT. 631-765-1802 r INSPECTI-ON [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. ] FOUNDATION 2ND [. ] INSULATION/CAULKING [ ]" FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT PENETRATION" [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: s DATE INSPECTOR gUfFOlt ��5�/ o`A' 1pG TOWN OF SO UTHOLD—WELDING DEPARTMENT H! Town Hall Annex.54375 Main Road P. 0-Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765--9502 hops://www.southoldtownn�.gov- Date Received . APPLICATION-FOR BUILDING PERMIT For Office Use Only 56 12qq - PERMIT No. Building Inspector f! AR 2 2024 �3 k Applications and forin`s'must,be'fiIled out in.th6i�,entirety,-Incomplei. te. .2 applications will not be accep#ed. UVhere the'Applicant'as.not the.owne'r;=an.::, Owner's Authorisation form ' lee Pae 2 . Date:.. . 3. 'P L bwNER(S):OF PROPERTY: Name: f SCTM#1000- ��i2 ' UQ ' 7 �:•:GOZ CCU Ct /.SS Project Address.' UI U . Ma.it' � .C.t. . :./V Phone#: WJ�• 3 ���.2��� Email: a/ /?"�)SS Mailing Address: 57 Gl I'. a CONTACT.PERSON Name: sl �iC � Mailing Address: J A Ue .0L,L...�C .. v !`�::,/�- v Ph one-#: ' �.� Email: - ROFESSIONAL�INFORMATION: DES GNP _ L 'I' Name:.. n. Oee ) j� ' - -- - - r l' MailingAddress: .��d b ��( ✓!._d.. :Rhone#: Email: 0 d' ��lo i e 6 -- 'hP,evr...- .ca1171 CONTRACTOR INFORMATION: . ' Name: Mailing Address: Phone#: 0 '_ 1. Email: DES IP ION,OF-PROPOSED COIVSTRlICT10N. CR ..T. - El e St ct re..ElAddition ❑Alteration ❑Repair ❑Demolition ' Esti m ated Cost Of.Proi�et: Cher �1 !�J' $ -- - -G�J - Will the lot be re-graded?' ❑Yes o Will excess fill be removed from premises? Elyes O ... ..... ... 1 .: •PROPERTY�INF - , Existing use of property: lihpGP :Intended use of property:- . , ,. . - .... Zone or use district in which premises is situated: Are there any covenants aro restrictions with respect to :this property? ❑Yes Lilo IF YES, PROVIDE A COPY. e owner contractor dell n' rofessional is ies"ohslble for all itraina'®and'storm water issues as provided by::,.. ;Ci�e_c ;Box-After,Readng� Th.• /, / g P. P. - g Chapter 236 of the Town Code;APPLICATION IS HEREBY MADE,to the Building Department for the issua`nce'ofa;Building Permit pursuant1. ..the Building Zone 'Ordieance of the tows of Southold;Suffolk;'Coynty,%N_' i,.Yo'rk;anil other apple W Laws,Ordinaoees o�Regulations,for the construction of buildings;. atJditions,alterations o •for rei"iyal or demoHildh as he described.The applicant agn:es,to comply with all applicable.laws;ordinances;building Bode; 'housing code'and tegul ition;and to a4rAiauthoraed inspectors on premises and in buildings)fog necessary Inspectibris:False statemeets made herein ere„ P State Penal Law:' , unishable as a Class A inlsdemeanorpursuant to Section.210 a5;of.the.New York uthorized Agent ❑Owner Application Submitte By(print name): �S�r,�Q �.el/J.l� g Signature of Applicant:- Date: STATE OF NEW YORK) COUNTY-OF. V being:duly sworn,deposes and says that(s)he is the applicant (Name of;iridividual signing_contract)above named, .'. (S)he.is the .. . ... .. (Contractor Agent; rporate Officer,etc.)' of said:owner.or owners, and:is:duly authorized:to. or have performed the said work and to make and:fiie.this application;that all statements contained in this application are true'to the best of his/her knowledge.and belief;and that the work will be performed in the-manner set forth in the application file therewith. Sworn:before me this f r / 20 � day o ! . �v--GE:. O. ,,� Notary, Ilc . . . . �' .: .. g 2: 933 , � . p.0 E633 r:� 1DtiF\�:O`ANY. : PROPERTYMNER AUTHORIZATION ` SSW. .ti� :';. .(Where the applicant is not the owner) 'residing at O 9L_Md M r, . >�h . .T lop, ��9� o-herebyauthorize ... to apply on. MY b h If to the T. . Southold Building:Department for approval as described herein. C . . Owner's Sig ature: Date HS S Rrint Owners Name 2 . o E 5_� F' & /-S 2 2�24 BU G DEPARTMENT-Electrical Inspector AUG TOWN OF SOUTHOLD c Town Hail Annex- 54375 Main Road - PO Box 1179 Department o guilding IDep Southold, New York 11971-0959 Town of'Ou Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh @,southoldtownny gov — sea nd@southoldtownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INF RMATION (AII Informati n Re u"sred) Date: f 2 Company Name: , .3-t P rU-) 1 C; Electrician's Name: License No.: Elec. email: Elec. Phone No:5_� request an em it copy of Certifica a of Compliance Elec. Address.: U JOB SITE INFORM TION (All Information Required) Name% � S Address: s- , Z Cross Street: Phone No.: Bldg.Permit#: email: 'an /SS Tax Map District: 1000 Section: Block: -7 Lot: � !2f RBRI D�SZC lm)OF WOF3kC�CLU��UARE F�,F � I�SE R��CIe;4�.�lS C�PaneI� � �-� � rams /sue Square Footage: Circle All That Apply: Is job ready for inspection?: YES❑NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES U"" Issued On Temp Information: (All information required) Service Size111 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame D Pale Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 011K Workers' CERTIFICATE OF INSURANCE COVERAGE YR STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier la.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. 202 Commerce Dr., Ste. 7 Moorestown, NJ 08057 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage Is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box 1a Southold, NY 11971 CG-52830-NY 3c.Policy Effective Period 11112024 To 12/31/2024 4. Policy provides the following benefits: ❑■ A.Both disability and Paid Family Leave benefits. ❑ B.Disability benefits only. ❑ C.Paid Family Leave benefits only. 5. Policy covers: ❑ A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as described above. Date Signed January 02, 2024 By l � ,T (Signature of insurance carrier's authorized representative or NYS licensed insurance agent of that Insurance carrier) Telephone Number 215-658-7318 Name and Title Carolynn Smith -VP Contracts IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111111111°°°1°1°1°°1°1°�1111°°11°111°IIIIII PORK Workers' CERTIFICATE OF SYAYE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE hoard 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street Suite 1400 1 c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-86426 4 Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e., 1 d.Federal Employer Identification Number of Insured or Social Security a Wrap-up Policy) Number - 2.Name and Address of Entity Requesting Proof of Coverage(Entity 3a.Name of Insurance Carrier Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY Town of Southold Town Hall Annex Building 3b.Policy Number of Entity Listed in Box"la" 54375 Route 25 P.O.Box 1179 WC 6142876-02 Southold,NY 11971 3c.Policy effective period 10/01/2023 to 10/01/2024 3d.The Proprietor,Partners or Executive Officers are Included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or Its licensed agent,or until the policy expiration date listed in box"3c",whichever Is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Mark Albi (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 1kl-a &1 10-01-2023 (Signature) (Date) Title: VP/Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)946-7500 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov _­­411 SUNRINC-02 TWANG .441cORO DATE(MM/DD/YYYY) �� CERTIFICATE OF LIABILITY INSURANCE 9/1/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#OC36861 No FACT Walter Tanner Alliant Insurance Services,Inc. P,vHc°Nr o,Ext): jAM,No): 560 Mission St 6th FI EMAIL San Francisco,CA 94105 .Walter.Tanner@alliant.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Evanston Insurance Company 35378 INSURED INSURERB:Zurich American Insurance Company 16535 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURERD: San Luis Obispo,CA 93401 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS Lr 2,000,000 A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS-MADE �X OCCUR MKLV5ENV104332 10/1/2023 10I1/2024 pREMSESOEaoccurre occurrence) $ 1,000,000 MED EXP(Any oneperson) 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY❑X JEo LOC PRODUCTS-COMPlOP AGG $ 2,000,000 X Retention:$200,000 Per Project Agg $ 5,000,000 OTHER: COMBINED SINGLE LIMIT 2,000,000 B AUTOMOBILE LIABILITY Ea accident $ Ix ANY AUTO BAP614287702 10/1/2023 10/1/2024 BODILY INJURY Per erson $ OWNED SCHEDULED AUTOS ONLYPx AUTOS BODILY INJURY Per accident $ HIRED NRN-OWNED ROPERTYDAMAGE CAUTOS ONLYAUTOS ONLY er accidentF5086Ded.: Coll.:Not Covered LiabilityDed.: $ 1,000,000 UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED RETENTION$ C WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY UTE E Y/N C614287602 10/1/2023 10/1/2024 1,000,000 ANY PROPRIETORIPARTNER/EXECUTIVE E.L.EACH ACCIDENT $ FFFICERIM�MFR EXCLUDED? I NIA 1 000,000 ((Mandatory inPIH) E.L.DISEASE-EA EMPLOYE If yes,desc be under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY-LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Evidence of Insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 Southold,NY 11971 AUTHORIZED REPRESENTATIVE ACORD 25(2016103) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD MIGHTY.. .. . . i ENGINEERING CO: March 18,:2024 . CERTIFICATION LETTER - Project Address:• JANIC6 FLISS RESIDENCE '565 OLD MAIN RD:: MATTITUCK,NY,11952 . ..... Design Criteria::: -Applicable Codes.=2020 NYSRC,2018 IRC/JBC/IEBC,ASCE 7-16 and:2018 NDS'- Risk Category=ll:: : :Wind Speed=.128 mph,Exposure Category B;Partially/Fully Enclosed Method Ground SnowLoad=25 psf = -ROOF AR=01 &AR-02:2 x 6 @ 24"pC,Roof DL­7 psf,Roof LUSL=19 psf(Non-PV),,Roof LUSL=12.5 psf(PV) :. :,•:•' . -'ROOF AR-03:2 x:10:@ 16"OC,Roof DL=9:psf,Roof LUSL=20 psf(Non-P.V),Roof LUSL=16.1:p'0(PV)'. ROOF AR-04:2 x:10 @:16"OC,Roof DL=9:psf,.R66f LUSL=19 psf(Non-PV);Roof LUSL=13.2 psf(PV)': To Whom It May Concern,.' A structural:evaluation of loading was conducted for the above address•based on the design,criteria•listed above. : . ' Existing roof structural' ming has been reviewed:fb'r additional loading due to insfallation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system: Based on-.this evaluation,I certify that the alferation to the existing structure by installation of.the PV system meets the prescriptive compliance requirements.of.the applicable existing building and/or new building:provisions adopted/referenced above.- Additionally,the PV module assembly.including attachment hardware has been-reviewed to be in accordance with the manufacturers: specifications and to meet and/or exceed the.requirements set forth bythe referenced codes.' OCCUPANCY( OR ... -:USE IS UNLAWFUL ::. :. Sincerely,::. :.: OFNEW DI signed WITHOUT CERTIFICATr AP RO ED AS NOTEDHAKyyy Digitally 9 b y 1P O Manouchehr' N OF OCCUPANCY = akhamanes i 3 10SBz � ,'—Date:-2024.03:18 Ff E BY: °�oFEss�ONp1y' 10:54:24'04.`00' NOTIFY BUILDING DEPARTMENT AT :..:. ;.... 0-765.1e02 8AM:M. 4PM FOR THE COMPLY I ITH ALL CODES'OF ELECTRICAL. . FOLLOWIN. .INSPECTIONS:: . ....: NEW YORK STATE &TOWN CODES::-..::INSPECTION REQUIRED 1. FOUNDATION-TWO REquIR> D AS REQUIRED:AND CONDITIONS OF . ....: FOR POURED:CONCRETE . :. :.2. ROUGH-.FRAMING&PLUMBING - = /OEL NZBAINSULATIONN PLANNING BOARD: :4.. .FINAL :CONSTRUCTION MUST BE COMPLETE:FORC.O. :: � �'��'���------ N TRUSTEES.. ALL CONSTRUCTION-SHALL MEET THE:.REQUIREMENTS OF THE CODES OF NEW .. YORK STATE. NOT RESPONSIBLE FOR .. .. . DESIGN OR CONSTRUCTON ERRORS PIP, Mighty.Engineeriri Co,I 1708.Roxbor6 gh'Rd Charlotte;NC282 1� I980)689.9776 Iinfq@rhi HtYen i neerin co.com . Pg 1:0f 8 .. a. . . . . . . . . . . . . . . . . . . . . . . . . . . . TOPSPEED ROOF ATTACHMENT DETAIL TO WOOD DECK :: REVISION: .. .. ... ... ... '' ;;, ;;, ;:, 1 1/28/2022 �NEW DETAR KiA EACH MOUNT HAS 1"'OF LEVELING CAPABILITY A 5/27/2022 DC001090 BDP .. • ROOF.OF SURFACE TO — ' REFER:TO SNAPNRACK INSTALLATION MANUAL FOR BOTTOM OF MODULE HARDWARE TORQUE SPECIFICATIONS HEIGHT .5I...: . 3.5-4 .. . ::. FOR ATTACHMENT SPECIFICATIONS,SEE: . ::. .. 'SNR-DC-30004 TOPSPEED,ATTACHMENT DETAIL, •:::. MOUNT TO WOOD.DECK° MODULE HEIGHT.OFF.ROOF: :' ROOFING MATERIAL,. FOR MOUNT PLACEMENT SPECIFICATIONS,SEE:. COMP SHINGLE,TYP: SNR-DC-30005 TOPSPEED,MOUNT.PLACEMENT ON.. 3Y2i-41%IN ' .... SOLAR PANEL'- ' BASE HEIGHT'UNDER SCREW:'• " "' FOR BASIC.SYSTEM INFORMATION SEE:. 600IN MINIMUM DECKnTHICKNESS: "SNR-DC-30006,TOPSPEED;SYSTEM OVERIVEW ON ""' "' " "' .. OSB COMP":' .'.:: .. .. ... ... .. ... 15 3Z'PLYWO :.' FOR SPECIAL CASE INSTALLATIONS SEE: :: "' :. "SNR-DC-30007 TOPSPEED,SPECIAL CASE INSTALLATION" MIN z�'PLYWOOD OR OSB ROOF DECK MIN 1/4"SCREW PROTRUSION MIN PROTURSION OF WOOD SCREW.THROUGH DECK. . . .. .. .. .. :. .. TOPSPEED .. MOUNTASSEMBLY' ATTACHMENT DETAIL ()(4)#141NOOD SCREWS,S.S., ROOFING MATERIAL FULLY EMBEDED INTO WOOD DECK mmm. COMP SHINGLE,:TYP. . ... :. ..' ...WOOD ROOF'.... ....' .. .. .. DECKING,TYP. :: FILL'"SPEEDSEAL"CAVITIES WITH APPROPRIATE ROOF SEALANT.TO WATERPROOF ATTACHMENT.. OVERVIEW. ... SEE INSTALLATION MANUAL FOR DETAILS ON', PROPER PLACEMENT ON COURSE n n �/[� "Sunrun South LLC M.AFFENTRANGER" SCALE: DRAWING NUMBER: - DESCRIPTION: REV: 5u•U� I��f Ion�W' s�w .� ooa.awrn.<sco.uw,m w DESIGNER �S u'+ u�+ vu ^°�N n +F^�„, TOPSPEED,ATTACHMENT DETAIL,MOUNT TO IIn� DRAFTER: M.AFFENTRANGER SNR-DC-30004 ;"" Solai Mounting Solutions K a� � ra . DA7: 5/27/2022: WOOD DECK ems ,,� s, < APPROVED BY' &PETERSON Powered by � DUO .a tea rs e :.... w' .10 PfaCr�:. catS<e1' t• • rML!, _ I rov etaroo PV r�� O�•ttlyT..trw 10.40072597 Q.ANTUM TECHNOLOGY:LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area,lower BOS costs,higher power classes,and an efficiency rate of up to 19.9%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE VJ Long term y eld security with Anti LID Technology,Anti PID Technology-,Hot-Spot Protect and Traceable Quality Tra.QT1". EXTREME WEATHER RATING High-tech alum n;um alloy frame,cart fied for high snow(5400Pa)and wind loads(4000Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty-. STATE OF THE ART MODULE TECHNOLOGY r _ Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. APT lest condr0ons according to IEC/IS 62804-1:2W.method B(-1500V.168h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooltop arrays on Rooftop arrays on resdentiai buidings commercial and industrial bur dugs Engineered in Germany OCELLS MECHANICAL SPECIFICATION ormat 66 3in x 39.4in x 1.26in(including frame) (1685mm x 1000mm x 32m m °0J-""'"'"' ue•ns,s,...i_._ .. L6C leWmmi .;.,eight 41.2lbs(18.7kg) Front Cover 0.13in(3 2mm)thermally pre-stressed glass with anti-reflection technology Back Cover Compositehkn Frame Black anodized aluminum Cell 6 x 20 manocryslelline Q.ANTUM solar hall cells Junction Box 2 09-3.98in x 1 26-2.36in x 0.59-0.71in � e4i (53-101mm x 32-60mm x 15-18mm).IP67,with bypass diodes Cable 4 mm2 Solar cable;(+)>_433m(1100mm)O 43.3tn(1100mm) e•a.�y..a. onnector Stbuba MC4,Hanwha Q CELLS HQC4,Amphentol UTX, Renhe05-6.TonglingTL-CableDlS,JMTHYJM601.IP68or ��sx•r,,,, uEruwea,otu�t Friends PV2e.IP67 Te>Yps .I -- ---- -- - ewr•axs..vI ELECTRICAL CHARACTERISTICS POWER CLASS 315 320 325 330 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE r5 W; ?rJJj Power at MPP' P­ IWI 315 320 325 330 Short Circuit Current' Isc JAI 999 10.04 10.10 10.15 E _ E Open Circuit Voltage' Voc IV) 39A4 40.10 - 40.36 40.62 Current at MPP Is,,, IAI 9.51 956 9.61 967 voltage at MPP V.- IVI 33.14 33.47 33.81 34.14 Efliciency' q I%I a18.7 >_19.0 >_193 a19.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT Power at MPP P_ IWI 235.9 239.6 2434 247.1 E Short Circuit Current Isc (A) 8.05 809 8.14 8.18 E Open Circuit Voltage Vx IVI 37.56 3781 38.06 38,31 2 Current at MPP I,,,,,p (A) 748 7.52 757 7.61 Voltag,at MPP Vsr,o IVI 31.53 3185 32.17 32.48 Measurement tolerances Pu,t3%•I;,Voc t5%at STC 1000 W/m2,25t 2'C,AM 1.5 eccording to lEC 60904.3.2800 W/m2,NMOT,spectrum AM 1.5 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98%of nominal power during ao --i--- a W ....,..".,�...,...�, first year thereafter max.0.54'K ' W S degradation per year Al least 93.1% of nominal power up to 10 years At least 85%of nominal power up t0 25 years q -_r___ r w ' All data within measuremenl tolerant- r O N es.full warranties in accordance with aee oee ilx, eae w � the warranty terms of the o CELLS sales organisation of your respective Q country et .Ee Typical module performance under low Irradiance c,mditicfrrs in ��"•""�''""''""' ° "`ter"'` comparison toSTC conditions(25'C,1000W/m2) 01 _ o TEMPERATURE COEFFICIENTS lompewtu+e .U,� a (x1K) 4004 Temperature Coafheient of Va I%/K) -0.27 Temperature Coefficient of P_ T (%11f: --0 3b Normal Module operating Temperature NMOT I'FI 109t5A(43t31C) PROPERTIES FOR SYSTEM DESIGN Maaimurn System Voltaye V IVI 1000(IEC)/1000(UL) Safety Cl.s, If Ro MadmumSaries Fuse Rating (ADCI 20 Fire Rating based onANSUUL1703 C(IEC)/TYPE2(UL) Max DesrgnLoad,Push/Pull' Ibs/ft2I 75(3600Pa)155(2667Pa) Permitted Module Temperature -40eFupto+185'F A Mal T1 _ (bs/ftfl 113(5400Pa)/84(4000138) onContlnucusDuty (-40'Cupto+85'C) u `Saekulal:at Ma at L QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION � UL 1703.VIDE Ouality,Tested.CE-comphant,IEC 61215.2016 w s0.2016. Number of Modules per pallet - _ 32 4 4ppttMa Cie-11,U.S Patent No 9,893,215(solar cel s No,nbe,of Pallets per 53 Trader 30 e Number of Pallets per 40•HC-Container' -� 26 DVE C E talus Pallet Dimensions{LxWxH) -- _ b9.3-453+46.9o(1760x1150x1190mm) sgr Pallet Weight 141`Abs(642kg) SC Nestle:Installation instructions must be followed.Seethe instal ation and operating manual or contact our technical service department for further inf-rma -non approved nstapali n end se of this product. Hat1wM Q CELLS Arelarlea Ino. 400 Spectrum Center Drive,Suite 1400.Irvine,CA 92618,USA I TEL.1 949 748 59 96 1 6"L rnquky@us.a-ce%s.com I WU www.q•cells.us solar=@@ • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE10000H-US/SE1140OH-US • solar-.-= ,mil solar,[' _Ha � 9 O o e e I o O � � O O Optimized installation with HD-Wave technology - Specifically designed to work with power optimizers - Record-breaking efficiency - Fixed voltage inverter for longer strings - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 - UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small — High reliability without any electrolytic capacitors — Built-in module-level monitoring 11111111111FID — Outdoor and indoor installation wave — Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us solar=ee Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US SE3000H US I SE380OH US , SE5000H_ _ US SE6000H US j SE7600H U11 00 S SE100H US SE11400H US --- — —i OUTPUT Rated AC Power Output 3000 3800 @ 3300 @ 2008 28V V 5000 55000 @ 24 0000,,@ 208V 7600 7600 10000 11400 VA Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,@ 208V 5000 @ 208V AC Output Voltage Min:Nom.-Max. Vac (183-208-229) AC Output Voltage Min:Nom.-Max. ,/ ✓ Vac (211-240-264) , AC Frequency(Nominal) 59.3-60-60.5(1I Hz Maximum Continuous Output Current _ 16 - 24 - - - A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A @240V. GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Cotry un Confi urable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - - Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 9 - 13.5 - - - Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 CEC Weighted Efficiency 99 Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20, Optional(2I Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG minimum/1-3 strings/ AWG Range 14-6 AWG 21.3x14.6x7.3/540x370 Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 x 185 in/mm Weight with Safety Switch 22/10 1 25.1/11.4 _ 26.2/11.9 38.8/17.6 lb../kg Noise <25 <50 dBA Cooling Natural Convection Natural convection _.... . ..... ....... ........... _... _.. Operating Temperature Range -13 to+140/-25 to+60(a((40'F/-40°C option)(<) F/'C Protection Rating NEMA 3R(Inverter with Safety Switch) Iu For other regional settings please contact SolarEdge support 2(Revenue grade inverter P/N:SE—W-USOOONNQ (31 For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (°(-00 version P/N:SExx H-USOOONNU4 120/240 VAC SINGLE PHASE SERVICE METER#: M PSEGLI98366514 ACC#:9691142003 NOTE:TOTAL PV SAC KFEED= UTILITY 31.25A GRID USED FOR INTERCONNECTION pF NEW SUPPLY SIDE TAP CALCULATIONS '�F, W y oa NO 09 * r 4 Or (N)LOCKABLE _ I EXISTING 200A BLADE TYPE MAIN BREAKER FUSED AC SOLAREDGE TECHNOLOGIES: 108135 Opp � T (END FED) DISCONNECT SE6000H-USS3 '�FESSIpNP I 6000 WATT INVERTER JUNCTION BOX PV MODULES EXISTING 3 �✓ 2 OR EQUIVALENT 1 HANWHA Q-CELLS:Q.PEAK DUO BLK Dlltall SI ned 200A MAIN , ✓ *$/ (17)MODULES g g PANEL — v OPTIMIZERS WIRED IN: by Nestor 35A FUSES (1)SERIES OF(9)OPTIMIZERS Oo'„' 1 SERIES OF 6 OPTIMIZERS o SQUARE D LOAD RATED DC DISCONNECT ( ) ( ) Houghton D222N B WITH AF COMPLIANT SHUTDOWN SOLD EDGE POWER OPTIMIZERS 3 Date: 2024.03.18 120/240VAC 10:55:23 -04'00' CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND sunrun 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 2 1 PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 D0825-M E 3 1 PVC OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THH N/THWN-2 (1)8 AWG THHN/THWN-2 maw—EN a Q—.NY IA.woe Eu zsei�i� 4 1 PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 CUSTOMER RESIDENCE: JANICE FLISS 565 OLD MAIN RD,MATTITUCK. NY,11952 MODULE CHARACTERISTICS TEL.(917)999-9999 5440 OPTIMIZER CHARACTERISTICS: HANWHA Q-CELLS:Q.PEAK DUO BLK APN:1000-122-00-07-00-002-000 MIN INPUT VOLTAGE: 8 VDC OPEN IR UIT400: 45, W MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 45.55 V MAX INPUT ISC: 14.5 ADC 216R-565FLIS MAX POWER VOLTAGE: 38.09 V MAX OUTPUT CURRENT: 15 ADC SHORT CIRCUIT CURRENT: 12.18 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 EJ AGUIBA SYSTEM SIZE: 6800 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 9 V ELECTRICAL SYSTEM OPERATING VOLTAGE. 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 3/182024 SYSTEM OPERATING CURRENT: 1T9A SYSTEM SHORT CIRCUIT CURRENT: 30A PAGE PV-4.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail Edge(LANDSCAPE/PORTRAIT) Overhang Overhang SNOW LOAD:25 PSF WIND SPEED: COMP SHINGLE- TOPSPEED,ATTACHMENT DETAIL,MOUNT 128 MPH 3-SEC GUST. AR-01 TOPSPEED 1-Story 2X6 RAFTERS 10'-3" 24" TO WOOD DECK:SNR-DC-30004 2/2 1'-6" 0'-10" FASTENERS: COMP SHINGLE- 24" 2/2 1 TOPSPEED,ATTACHMENT DETAIL,MOUNT (4)#14 X 2.25"SS SEALING AR-02 TOPSPEED -Story 2X6 RAFTERS 10'-4" TO WOOD DECK:SNR-DC-30004 -6 0'-101, WASHER WOOD SCREWS FULLY PENETRATING THROUGH WOOD COMP SHINGLE- ,6" 2/2 1'-6"TOPSPEED,ATTACHMENT DETAIL,MOUNT 01-10" DECK AR-03 TOPSPEED 1-Story 2X10 RAFTERS 15'-5" TO WOOD DECK:SNR-DC-304 00 AR-04 COMP SHINGLE- ,-Story j 2X10 RAFTERS 9'-01, 16" TOPSPEED,ATTACHMENT DETAIL,MOUNT 22 1'-6" 0'-to..TOPSPEED I I I I TO WOOD DECK:SNR-DC-30004 D1-AR-01-SCALE:3/16"=V-0" D2-AR-02-SCALE:3/16"=V-0" AZIM:254° AZIM:74° PITCH:31° PITCH:31° 2 I � �aF�Kwy�9 * Q. yr„ 6.11" n - , 103982 tv`� SSIONP� 3'-9'. 9 E)7 �10" 1 1-4'-6"— 6'2" —3'-11"-1� 1-6-2-119' sunrun T,,I,. 03-AR-03-SCALE:1/8"=1'-0" - D4-AR-04-SCALE:1/8"=1'-0" AZIM:254° INSTALLERS SHALL NOTIFY ENGINEER OF AZIM:74° 00825-ME PITCH:20° ANY PITCH:29° n ux.incue coat r+wo�s.euer H.nseo POTENTIAL STRUCTURAL ISSUES OBSERVED r1'-3" ®z ,x� PRIOR TO PROCEEDING W/INSTALLATION. 12'-6" 18'-8" Fq ouE -MOUNT NUMBER FOR LEADING CUSTOMER RESIDENCE: S JANICE FUSS EDGE i 565 OLD EDGE SHHALLALL MATCH REQUIREMENTS LISTED z 2'_4" NY,11952 MAIN RD,MATTITUCK, ABOVE INSTALL PER TOPSPEED INSTALLATION MANUAL. TEL(917)999-9999 6'-1 V' APN:1000-122-00-07-00-002-000 -CONTRACTOR MAY SUBSTITUTE I PROJECT NUMBER: it" SNAPNRACK 216R-565FLIS DECKTRACK MOUNTS(SNR DETAIL SNR-DC-00453)WITH A MAX OVERHANG OF 6 DESIGNER: (415)580-6920 ex3 EJ AGUIBA SHEET 2' LAYOUT i REV:A 3/182024 3'-7" —841—'—<14'-3"— PAGE PV-3.0 SITE PLAN-SCALE=3/32"=V-0" SITE PLAN DETAIL-SCALE 1M28"-l'-0" (E)GATE (E)DETACHED STRUCTURE (E)FENCE ROOF PATHWAYS (3'TYP) Q"i (E)FENCE (E)DETACHED STRUCTURE (N)ARRAY AR-04 (E)DRIVEWAY (N)ARRAY AR-03 PL ,�(OF NEW�, haEpR H,1KH' RO C�_'D n FIRE SETBACKS (18"TYP) A 103982 (E)RESIDENCE '�Rr7FESSl101 ONP� INV AC SE (N)ARRAY AR-02 sunrun 0 00825-ME Rao nESTRNRr.N.nsso (N)ARRAY AR-01 -.2.1- ARRAY TRUE PV AREA CUSTOMER RESIDENCE: ROOF PATHWAYS PITCH AZIM (SQFT) JANICE FUSS IT TYP) AR-01 31° 254° 634 565 OLD MAIN RD,MATTITUCK, NY,11952 AR-02 31' 74' 42.3 AR-03 20° 254° 126.8 TEL.(917)999-9999 APN:1000-122-00-07-00-002-000 AR-04 29° 74' 126.8 PROJECT NUMBER: 216R-565FLIS LEGEND ❑ AC ELECTRIC VEHICLE MICROGRID ❑GROUNDING MOD LES DESIGNER (415)580-6920 ex3 SM SUNRUN METER AC DISCONNECT(S) EV SUPPLY EQUPMENT MD INTERCONNECT DEVICE ELECTRODE EJ AGUIBA SCALE:NTS NOW:NOT ALL ITEMS IN LEGEND DC + ENERGY STORAGE INTERIOREQUIPMENT N U AAPPEAR IN SITE PLAN pM DEDICATED PV METER DC DISCONNECT(S) �' MA METER ADAPTER SHEET SYSTEM L J SHOWN AS DASHED TOPSPEEO SITE PLAN SE SERVICE ENTRANCE SP SUB-PANEL INV INVERTER(S) AM ACREL METER BI BACKUP INTERFACE O CWI WIRES BG BACKUP GATEWAY REV:A 3/182024 MP MAIN PANEL LC PV LOAD CENTER EM SOLAREDGE METER CB IQ COMBINER BOX BP BACKUP LOADS PANEL Z STORAGE SYSTEM ESS) GP GENERATION PANEL PAGE PV-2.0 INVERTER 1 NOTES AND SPECIFICATIONS. •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE • PHOTOVOLTAIC SYSTEMPHOTOVOLTAIC • DISCONNECT 11021(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690.OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. COMBINER PANELMAXIMUM SYSTEM VOLTAGE: qgp • .SIGNSAND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD DO NOT ADD LOADS WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED N 30 • •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION: •• • METHOD AND SHALL NOT BE HAND WRITTEN THE OPEN POSITION PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE). • '• ••1 •1 • • 15 1 INVOLVED. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S)CEC 2019 705.12(BJ(2X3)(c), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER ACIDICPANE (IF NEC 2017:705.12(B)(2)(3Xc) LABEL LOCATION: AC COMBINER PANEL QF APPLICABLE). INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):CEC 2019:690.13(B),NEC PER CODE(S):NEC 2017:69053 2017:690.13(B) I DUAL POWER SUPPLY .t Of NEW 70! SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID � NOT RELOCATE THIS AND PV SOLAR ELECTRIC � 501< Ho OVERCURRENT DEVICE SYSTEM * r LABEL LOCATION: LABEL LOCATION. ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN W APPLICABLE). SERVICE PANEL PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(B)(3),NEC 705.12(BX2X3Xb),NEC 2017: 2017:705.12(BX3) 108135 705.12(BX2X3Xb) ��FE$SIONa� • FOR SOLAR PV SYSTEM BUILDING SUPPLIED BY UTILITY GRID AND PHOTOVOLTAIC LABEL LOCATION SYSTEM INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S):CEC 2019:690.5NCX3),NEC IM4.,3.CFC 201 IFC 2012.605.11.1,IFC 2018: s u n r u n 1204.5.3,CFC 2019:1204.5.3 4" SOLAR PV SYSTEM EQUIPPED 8 00825-ME 7�r�E�a�N61•WY.W„ WITH RAPID SHUTDOWN 1-1.51 , FA��®2� POWER • CUSTOMER RESIDENCE: PV SvsTEM JANICE FUSS LABEL LOCATION'. DISCONNECT-EXTERIOR GNo FLooR 565 OLD MAIN RD,MATTITUCK,INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, NY,11952 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3 TURN RAPID SHUTDOWN MAIN PANEL-INTERIOR BASEMEN ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF" TEL.(917)999-9999 PER CODE(S):CEC 2019 690.31(G)(3).690.31(GX4), POSMIN TO SHUT DOWN w... . APM 1000-122-00-07-00-002-000 NEC 2017:69031(GX3),690.31(GX4)IFC 2012: - 605,1114 PV SYSTEM AND REDUCE LABEL LOCATION SHOCK HAZARD IN THE POINT OF INTERCONNECTION PROJECT NUMBER: ARRAY. (PER CODE'.NEC690.56(B),NEC705.10,225.37,230.2(E)) 216R-565FLIS PHOTOVOLTAIC AC DISCONNECT •• *xrlII. . DESIGNER: (415)560-6920 ex3 LL EJ AGUIBA NOMINAL•• 1 VAC L SHEET LABEL LOCATION LABEL LOCATION SIGNAGE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019:690-54,NEC 2017:690,54 ARE CONNECTED REV A 3/182024 PER CODE(S):CEC 2019:690 56(C)(7 Xa),NEC 2017: 690.56(C)(1)(a) PAGE PV-5.0 SHEET INDEX SCOPE OF WORK GENERAL NOTES PAGE A DESCRIPTION •SYSTEM SIZE:680OW DC,6000W AC •MODULES:(17)HANWHA Q-CELLS:Q.PEAK DUO ELK •ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE PV-1.0 COVER SHEET ML-G10+/T 400 WITH 20181RGIBGIEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. SE6000H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT •RACKING:TOPSPEED,ATTACHMENT DETAIL,MOUNT TO PV-4.0 ELECTRICAL WOOD DECK:SNR-DC-30004 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. P.`tI,OV NEW f,O PV-5.0 SIGNAGE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY h� 4 HAKy�` 54, GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. or f7 •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 103982 V •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. �OpjPOF.ESS�ONp��� •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. Digitally Signed •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC690.12(1). by ManOUchehr •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). H a kha m a n es h I •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. Date: 2024.03.1 8 •12.18 AMPS MODULE SHORT CIRCUIT CURRENT. l 10:54:43 -04'00' •15.23 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. sunrun 00825-ME ABBREVIATIONSVICINITY MAP CANTIADDERDa RQaDY.ESTBURY.NY1, PHONE&I55m 590] A AMPERE C _ %6a52.2- AC ALTERNATING CURRENT CUSTOMER RESIDENCE: AFC ARC FAULT CIRCUIT INTERUPTER 8 JANICE FUSS AZIM AVMUTN - O 565 OLD MAIN RD,MATTITUCK, NY,11952 coMP COMPOSITION C•-- ® Lw„ DC DIRECTCURRENT TEL.(917)999-9999 (E) EXISTING APN:1000-122-00-07-00-002-000 ESS ENERGY STGRAGESYSTEM PROJECT NUMBER: MSP MAIN SERVICE PANEL • o�O`� 216R-565FLIS IN) Nm DESIGNER: (415)580-6920 ex3 PRE-FAB PRE-FABRICATED oMw,a^Pd EJ AGUIBA PSF POUNDS PER SQUARE FOOT O SHEET PV PHOTOVOLTAIC O COVER SHEET R50 RAPID SHUTDOWN DEVICE TL TRANSFMMERLESS REV:A 3/18/2024 v voLTs PAGE PV-1.0 W WATTS