Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
48872-Z
�o�Og11FFOl�CpG Town of Southold 8/20/2024 y�. P.O.Box 1179 0 o 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45468 Date: 8/20/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 805 Theresa Dr,Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-15-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/20/2023 pursuant to which Building Permit No. 48872 dated 2/7/2023 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Volinski Fmly 2023 Irry Trt of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48872 7/1/2024 PLUMBERS CERTIFICATION DATED -0 0 tho ize S gnature �SufFat TOWN OF SOUTHOLD BUILDING DEPARTMENT y. :x TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48872 Date: 2/7/2023 Permission is hereby granted to: Volinski, Mark 805 Theresa Dr Mattituck, NY 11952 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 805 Theresa Dr, Mattituck SCTM #473889 Sec/Block/Lot# 115.-15-7 Pursuant to application dated 1/20/2023 and approved by the Building Inspector. To expire on 8/8/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector *pF SOUT�o! Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 97 1-0959 O • �o sean.deviin(a-)town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mark Volinski Address: 805 Theresa Dr City:Mattituck st: NY zip: 11952 Building Permit#: 48872 Section: 115 Block: 15 Lot: 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: NYSS License No: 62692ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic -Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED F1 Exit Fixtures Sump Pump Other Equipment: 8.1 kW Roof Mounted PV Solar Energy System w/ (20) REC405AA Pure-R Modules 7.6kW Solar Edge SE7600H Inverter, on Backfed 40A Breaker in Main Panel Notes: Solar Inspector Signature: Date: July 29, 2024 S.Devlin-Cert Electrical Compliance Form(1) SO(/r�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 97 1-0959 �c�lyC sean.devlinCa�town.southold.ny.us 4UNN BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mark Volinski Address: 805 Theresa Dr city:Mattituck st: NY zip: 11952 Building Permit#: 48872 section: 115 Block: 15 Lot: 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Peconic Bay Electric Corp License No: 46360ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X. Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 200A Panel 40 Circuits / 30 Used Notes: New Service Inspector Signature: Date: July 1, 2024 S.Devlin-Cert Electrical Compliance Form r,tjf So # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I LATION/CAULK G [ ] FRAMING/STRAPPING [ FINAL Z [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: flN--L* ks mzi--- r X) (ou . DATE %J2- INSPECTO SOGTyo� � v .Q�� C�l # TO WN WN OF SOUTHOLD BUILDING DEPT. courm 0 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING/- FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) "Y ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Affe o h" as- ZP 1AIll, ® � a 1 -Z-e in rO V'Irj � DATE �� INSPECTOR ' *pf SOUly�lo L4 � Q -67 2- W e� -77-2dir�64 < l� TOWN OF SOUTHOLD BUILDING DEPT. °ycoum,��' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [. .] FOUNDATION -2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] .CODE VIOLATION [/ ] PRE C/O [ ] RENTAL REMARKS: � �_ r 1) 1 LA Z!2 to c(a 0 DATE 1INISPECTOR i r r yyl AU v 4 � � N � m~ � j r 1 . � � "' I, � : � , � � � � ► . �� � � � � ,, r � �� ��,� , � . �� _, . �� , �� , . , ,� . , r��� -� - �� 1 ' i . �- ..�.. � . � h'' � �+► �` � � � �. � � � � '�� � '!� . # - _ �_ M- � 7 :��,� � . . � � r.. � t4�� N' FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) y •------------------------------------ ------------------ __ FOUNDATION (2ND) z 0 ROUGH FRAMING& , PLUMBING bt INSULATION PER N.Y. STATE ENERGY CODE O �1 FINAL CJ r l M '�1 ADDITIONAL COMMENTS 0 �,70 1. 74 S a3 -PQ47ic v — , c- d 3 3 c�►c SarJiLR- o -j as y -rn � ;o �O b H O z y� d .. b H o�SUFFoc,r�oG;. TOWN OF SOUTHOLD-BUILDING DEPARTMENT y _ Town Hall Annex 54375 Main Road P. O. Box.1179 Southold,NY 11971-0959 % • of Telephone(631) 765-1802 Fax(631) 765-9502 https://i ww.southoldtgm2u.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only .. j f -PERMIT NO. Building Inspector: �f J O 2 0 2023 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an BuILTNNG DEPT. Owner's Authorization form(Page 2)shall be completed. TG v N OF SOTi AIDI LD Date: OWNER(S)OF PROPERTY: Name: Mark Volinski SCTM#1000- Project Address: -805.Theresa Drive, Mattituck, NY 11952 Phone#: 516-658-7247 Email: mvolinski@aol.com .Mailing Address: 805 Theresa Drive, Mattituck, NY-11952 CONTACT PERSON: :Name:Reid Garton Mailing Address: 132 West 31 st,New York, New York Suit 1300 Phone#: _ 516-418-2131 Email: permitting@nystatesolar.com DESIGN PROFESSIONAL INFORMATION: . Name:Robert Masone Mailing Address: 132 West 31st; New,York, New York Suit 1300 Phone#: 516-418-2131 Email: permitting@nystatesolar.com CONTRACTOR INFORMATION: Name:Reid Garton Mailing Address: 132 West 31st,New York, New York Suit.1300 Phone#: 516-418-2131 Email: permitting@nystatesolar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure [--]Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther Solar Panel $ 32,674.10. Will the'lot be re-graded? ❑Yes IRNo Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Sih 1kM(�y.� �eSiGlQv�ha� Intended use of property: p Sri rutl2�0.C1�1,t1 e S I�-YL�]�4_ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect.to this property? ❑Yes.ERNo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): DAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ei ) Reid Garton being duly sworn_,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is:the Reid Garton. (Contractor,Agent;Corporate Officer; etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this ,application;that all statements contained'in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set.forth in the application file therewith. Sworn before me this day of 11 knc 4P 20 Notary Public QUINCINE DOLORES THOMAS PROPERTY OWNER AUTHORIZATION Notary Public=State of New.York NO.'01TH6420285 (Where the applicant Is not the owner) .. Qualified in Kings'County My Commission Expires Aug 2,2025 i I;. . Mark Volinski residing at 805 Theresa Drive, Mattituck, NY 11952 do hereby authorize Reid Garton to apply on my behalf to the Town of.Southold Building Department for approval as described herein. MarkVolinski(Nov21,202211:30 EST) Nov 21,2022 Owner's Signature Date Mark Volinski PrintOwner's Name 2 BUILDINGMEPARTMENTTmw Elecfridl Inspector 4TOWN OF SOUTHOLD. Towry Hall,Annex, .54375 Main Road = PO,Box 1479+ •ra 1:1971-0,959 ..�:•-: " o_uth_old,New-York; =� o '`. fiele hone 631 FAX 63-1)165=9,502; r.OQ H(a�southoldtownriy:go'v- seand0--southoldtowndy-'. _- -APPLI07' :ION FOR'ELECTRICAL,INSPECTION; ELECTRICIAN INFORMATION (All Information Required); Date: Company_Name: - _-- NYSS— Name:-�--yJamie ----_- - - - -- - - - -- _-_ I . -� _Minnick _ License-No. M .7 (p L 2 :eir . permitting@nystatesolar.com :Address:; ,, - __1.32=West-31 st.-New Yock-New York-SuitA 300. Phone-No:: 516=418.2131 JOB MTE.INFORMATIwON' WhIor,ation Reguiied);. {. Name: _Mark_V_olinski _ — -! Address: 805-Thereta_Ddve Mattituck�_NY_11.952 -._ Cross4St�ee$ _ - - - -- - --- +I ..Phone No: 6.58-7.247 — - - - ---- - -- - - - - -- -- -=- - - - '� . '_- Bldg.-Permit#: email: mvolinski@aol.com Tax_M'ap i District:__ _1:000!_ Section:__ _ -- Block: T--- - _Lot: 9RIEF DES_C_RIPTION,OF WORK(Please'Print Clearly), . .i_-_-Gnd.-tied_fixed roof mount_solar_panel_installation ' -IR - /�1_ Cc�le,AI1;Ta AppE ;; - - . Is job=ready for inspection?: YES/ NO Roughrin Final' Do you need a;Ternp'Certifcafe? YES;' NO' Issued,_On, -. - --- - - Temp'Informatiori __miation_rcequired): --(All info_ - ' Service Size; 1 Ph -3 Ph Size: A; #Meters ;Old Metet•# -_ New Service_ Flrej Reconnect= Flood Reconnect.-.Service:-Reconnectedi-,Underground =:Oveheatl;. #?Und'ergroun`d-=,Laterals. 1 =2, . H-Frame` __:.._Pole;T -:Work dorie--on Service?' Y. . :N - - -Additional Information.------'- -- - - - �- fTP --.-- - - -- ;PAYMENT_•D.UE WI-T_N.APPLICATION.7 . BULDMIG DES' ,�Re ii st f fob, pea iiiq, Itr yds L7 a J. { S �� BUILDING DEPARTMENT- Electrical Inspector Je TOWN OF SOUTHOLD °f Town Hall Annex - 54375 Main Road - PO Box 1179 o Qr Southold, New York 11971-0959 � . "�" Telephone (631) 765-1-802 - FAX (631) 765-9502 rogerr _southo.ldtownnygov seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: NYSS Name: Jamie Minnick License No.: ME- &I-(,cl Z. email: permitting@nystatesolar.com Address: 132 West 31st New York .New York Suit 1300 - Phone No.: 516-418-2131 JOB SITE INFORMATION (All Information Required) Name: Mark Volinski Address: 805 Theresa.Drive Mattituck NY 11952 Cross Street: Phone No.: 516-658-7247 Bldg.Permit#: email: mvolinski@aol.com Tax Map District: - 1000 Section: -. --Block: Lot: BRIEF DESCRIPTION;OF WORK (Please Print Clearly) Grid tied fixed_ roof mountsolar panel installation I panoi r )rl 2-0 d ;l r L,Li,T lar-c V-c Ls Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: - -A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N -Additional Information: PAYMENT DUE.WITH APPLICATION J A f11 2 0 2323 r;R uest fof l(►speatiotr Fnrm�cls � �; ,- �� � � �, s � � v %�°� u�� s � ���� H E C E � U JUL 2 9 2024 Do �o��SuFFD(k�o BUILDING DEPARTMENT- Electrical Inspector Gym TOWN OF SOUTHOLDBuilding Department o =` Town Hall Annex- 54375 Main Road XP0I36k4V&Id o Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh southoldtownny.cov- seanda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION qP?76? ELECTRICIAN INFORMATION (All Information Required) Date: 7/24/24 Company Name: Peconic Bay Electric Corp. Electrician's Name: Jose M. Umana License No.: ME-46360 Elec. email:pecbayelec@gmail.com Elec. Phone No: 631-987-4406 ❑✓ I request an email copy of Certificate of Compliance Elec. Address.: 218 Oak Ave, Flanders, NY 11901 JOB SITE INFORMATION (All Information Required) Name: Mark Volinski Address: 805 Theresa Dr, Mattituck, NY 11952 Cross Street: New Suffolk Ave Phone No.: 631-603-7084 Bldg.Permit#: H EE�7 Z email:.mvolinski@aol.com Tax Map District: 1.000 Section:115 Block: 15 Lot:7 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Electrical service upgrade to 200A Vw.v4- ^cr G P P`'ea Fo r Nv Arc. Square Footage: Circle All That Apply: Is job ready for inspection?: YES❑NO ❑Rough In 7 Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION coffvt- :. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 a' Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ®� rogerr southoldtownny.gov - seandpsoutholdtownn .qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: NYSS Name: Jamie Minnick AA 1 Ae License No.: c,Z�,cl 2- email: permitting@nystatesolar.com Address: 132 West 31 st New York New York Suit 1300 Phone No.: 516-418-2131 JOB SITE INFORMATION (All Information Required) Name: Mark Volinski Address: 805 Theresa Drive Mattituck NY 11952 Cross Street: Phone No.: 516-658-7247 Bldg.Permit#: email: mvolinski@aol.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Grid tied fixed roof mount solar panel installation I �1 joc no i c Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size Ph 3 Ph Size:<�A #Meters _ Old Meter# i �ew Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: / PAYMENT DUE WITH APPLICATION 17 R uest for Inspection Forrrrvc �, Is , ACCO CERTIFICATE OF LIABILITY INSURANCE DATE(MM►DDIYYYY) 6/30/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WANED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In Ileu of such endorsement(s). PRODUCER CONTACT Marsh&McLennan Agency LLC FAX 4900 Libbie Mill East Boulevard PHONE M.800-285-1778 A/c No): Suite 100 ADDRESS: certificates@MarshMMA.com Richmond VA 23230 INSURERS AFFORDING COVERAGE NAIC# INsuRERA.Utica Mutual Insurance Company 25976 INSURED NYSSLLC INSURERB:Colony Specialty Insurance Company 36927 NYSS,LLC 132 W 31st St Suite 1300 INSURERC:Southwest Marine&General Ins Co 12294 New York NY 10001 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:793398451 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MMOLICY EFF YYYI MMIUDD EXP LIMITS C X COMMERCIAL GENERAL LIABILITY Y Y PKG202100018285 7/1/2022 7/1/2023 EACH OCCURRENCE $2,000,000 CLAIMS-MADE FK OCCUR D AMA PREMI E SESEa TO RENTED occurrence $100,000 MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $4,000,000 X POLICY JECTT LOC PRODUCTS-COMP/OP AGG $4,000,000 OTHER: $ A AUTOMOBILE LIABILITY Y Y 5521461 7/1/2022 7/1/2023 COMBINED SINGLE LIMIT $1,000,000 Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED X SCHEDULED AUTOS ONLY AUT O S BODILY INJURY(Per accident) $ X HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident B X UMBRELLALUIB X OCCUR Y Y EX04279465 7/1/2022 7/1/2023 EACH OCCURRENCE $3,000,000 EXCESS LIAR CLAIMS-MADE AGGREGATE $3,000,000 DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- ANDEMPLOYERS'LIABIUTY YIN STATUTE I ER ANYPROPRIETORIPARTNERIEXECUTIVE El N/A E.L EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory In NH) EL DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below I.E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached N more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 PO Box 1179 AUTHORIZED REPRESENTATIVE Southoidd NY 11791 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Labor,Licensing&Consumer Affairs f, t HOME IMPROVEMENT LICENSE f Name REID T.GARTON 3 Business Name its certifies that the parer is duly licensed NYSS LLC DBA the County of suffolk License Number:HI-62273 Rosalie Drago Issued: 06/03/2019 Commissioner Expires: 06/01/2023 Suffolk County Dept.of Labor,Licensing 8 Consumer Affairs • r MASTER ELECTRICAL LICENSE Name JAMIE MINNICK Business Name 'hat t'ne NYSSLLCDBA bearer is duly licensed 'by the County o!suWk License Number:ME-62692 Rosalie Drago Issued: 1111912019 Commissioner Expires: 1110112023 GENERAL NOTES EQUIPMENT LIKELY TO BE WORKED UPON OF NEW WHILE ENERGIZED SHALL BE INSTALLED IN E W y 1 LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26 * Ow O CONTRACTOR SHALL USE ONLY COMPONENTS � m 2 LISTED BY A NATIONALLY RECOGNIZED W TESTING LABORATORY FOR THE INTENDED USE CONTRACTOR IS RESPONSIBLE FOR F 084951 �V FURNISH NG L RELATED 0 y 3 CABLES,IADD TIONAL CONDUQITS BOXES, opSSIONP�� RACEWAYS,AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM THE SYSTEM SHALL COMPLY WITH NEC [364-J [3saI ARTICLE 690,ALL MANUFACTURERS LISTING 4 AND INSTALLATION INSTRUCTIONS,AND THE a RELEVANT CODES AS SPECIFIED BY THE Q AUTHORITY HAVING JURISDICTION'S(AHJ) APPLICABLE CODES 0 WHERE DC PV SOURCE OR DC PV OUTPUT 8 CIRCUITS ARE RUN INSIDE THE BUILDING,THEY F SHALL BE CONTAINED IN METAL RACEWAYS, _il TYPE MC METAL-CLAD CABLE,OR METAL Q THERESA.DRIVE 5 ENCLOSURES FROM THE POINT OF V) $ PENETRATION INTO THE BUILDING TO THE } FIRST READILY ACCESSIBLE DISCONNECTING z z 8 MEANS,PER NEC 690.31(G) 1 SITE PLAN PV-2 SCALE:1/32"=V-0" z O R324.6 ROOF ACCESS AND PATHWAYS-ROOF ACCESS,PATHWAYS,AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R.324.6.2.1.ACCESS AND MINIMUM Q Y > Lo SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF,TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF,PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS,AND TO 2 Z U lj 0) PROVIDE EMERGENCY EGRESS FROM THE ROOF. O JZ m} EXCEPTIONS: z O Cl Cl Z 1.DETACHED,UNINHABITABLE STRUCTURES,INCLUDING BUT NOT LIMITED TO DETACHED GARAGES,PARKING SHADE STRUCTURES,CARPORTS,SOLAR TRELLISES AND SIMILAR STRUCTURES,SHALL NOT BE > Y REQUIRED TO PROVIDE ROOF.ACCESS. W Lu Y 2.ROOF ACCESS,PATHWAYS AND SETBACKS NEED NOT BE PROVIDED WHERE THE BUILDING OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE EMPLOYED. O Q Ly C 3.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL(17-PERCENT SLOPE)OR LESS. H co < ap o — fn (NY)R324.6.1 PATHWAYS=NOT FEWER THAN TWO PATHWAYS,ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDE AND NOT LESS THAN 36 INCHES(914MM)WIDE,SHALL BE PROVIDED ON ALL 0 BUILDINGS.NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF.FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A PATHWAY NOT LESS THAN 36 U INCHES WIDE(914MM)SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY,ON AN ADJACENT ROOF PLANE,OR STRADDLING THE SAME AND ADJACENT,ROOF PLANES.PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS DR1N"L IM Ol VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT.PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS,RAFTER,OR OTHER SUCH FRAMING SYSTEM THAT DATE 17 ah lvovmn SUPPORTS THE PATHWAY. SGILE: EXCEPTION:ACCESS PATHWAYS SHALL NOT BE REQUIRED ON ROOF SLOPES CONTAINING PHOTOVOLTAIC MODULES,PANELS,OR AN ARRAY WHERE THE OPPOSING OR ADJACENT ROOF SLOPE IS AN ACCESS NTS ROOF. >1rLE: (NY)R324.6.2 SETBACK-AT RIDGE-PHOTOVOLTAIC ARRAYS SHALL NOT BE LOCATED LESS THAN 18 INCHES(457MM)FROM A HORIZONTAL RIDGE. SITE PLAN PV-2 r AP VED AS NOSE® DATE: B.P.# FEE: ! 6 BY: NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTPUCTION MUST GC BE COMPLETE --OR C.O. 1 '1 �le ALL CONSTRUC-I ivN SHALL MEET THE ! CF REQUIREMENTS OF THE CODES OF NEW bt, YORK STATE. NOT RESPONSIBLE FOR Wted--c-- DESIGN OR CONSTRUCTION ERRORS. /,a COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S -D-TQl*l 79A- ��SOJFO- -%WRJ-Rk�IIuI G BOARD SO4THOLDIDWITMUSTEES OCCUPANCY OR USE I8,0- NLAWFVL 'NITy0UT-CERTIFICAT .)F OCCUPANCY a , Design Professional's Certificate of Compliance 11/02/2022 Town of Southold Building Department 54375 NY-25 Southold, NY 11971 Subject: Solar Installation for Mark Volinski 805 Theresa Drive. Mattituck. NY 11952 1 have reviewed the roofing structure at the subject address. The structure can support the additional weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE/SEI 7-22 when installed in accordance with the manufacturer's instructions. I have come to the following conclusions regarding framing structure, roof loading, and site location of proposed solar installation: Roof Section 1 2 Mean Roof Height 13' 12' Pitch 23 22 Roof rafter 2 x6 2x6 Rafter Spacing 16" 16" Reflected roof rafter span 13A 13.1' Table R802.4.1 (1) max allowable 14'.4" 14'.4" Climatic and Exposure Ground Wind Fastener Type Geographic Design category Snow Load, Speed,3 Criteria Pg,psf scc gust, mph Roof Section 1 B 30 135 SS 5/16" dic, 2 B 30 135 SS 5/16" dilc Sincerely, Robert Masone, PE F,�F NEW Professional Engineer -�. i`N J A N 2 0 2023 r- W 084951 A'��FESSI4N�� 1 'J DIRECTORY OF PAGES v SCOPE OF WORK OF NEW PV- 1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF C, TT O� SOLAR PANELS. THE SOLAR PANELS WILL BE PV-2 SITE PLAN RACKED USING A PREENGINEERED RACKING PV-3 ATTACHMENT PLAN SYSTEM. THE RACKED MODULES WILL BE e ELECTRICALLY CONNECTED WITH DC TO AC 4, PV-4 ATTACHMENT DETAILS POWER INVERTERS AND INTERCONNECTED TO THE �zz� LOCAL UTILITY USING MEANS AND METHODS `rF� 084951 PV-5 3-LINE DIAGRAM CONSISTENT WITH THE RULES ENFORCED BY THE PV-6 SAFETY LABELS LOCAL UTILITY AND PERMITTING JURISDICTION. FESSI�NP� x MODULE DATASHEET cl INVERTER DATASHEET w o SYSTEM DETAILS CL MOUNTING SYSTEM DATASHEET CL Q 805 Theresa Dr, o MOUNTING SYSTEM ENGINEERING LETTER 61 MattltUCl{, NY 11952 d NEW GRID-INTERACTIVE DESCRIPTION PHOTOVOLTAIC SYSTEM T WITH NO BATTERY STORAGE _ PROJECT DETAILS ANNUAL PRODUCTION 8,390 KWH z > O N Z DC RATING OF SYSTEM 8,100 W " E ZONING RESIDENTIAL o AC RATING OF SYSTEM 7,600 W LL U. 7� O lf USE AND OCCUPANCY SINGLE FAMILY INVERTER(S) (�)SOLAR EDGE TECHNOLOGY �' CLASSIFICATION DWELLING SE7600H o 0 INVERTER TYPE STRING INVERTER o _ o PERMITTING AUTHORITY `a x 5F Mat itUCk UTILITY COMPANY PSE&G New York MODULE (20)REC405AA PURE-R U c'z METER SERIAL NUMBER 40.990464,-72.506062 O N3Y NEC VERSION 2017 NEC (NFPA 70) Z Map data INTERCONNECTION DETAILS FIRE CODE 2020 NYS RESIDENTIAL LOAD SIDE AC Z CODE, IBC 2015. POINT OF CONNECTION CONNECTION PER NEC Q _ ARTICLE 705.12(D) Q Y N LO UTILITY SERVICE 120/240 V `- CONTRACTOR INFORMATION O z U o J Z MAIN SERVICE PANEL LL cB z COMPANY NY STATE SOLAR 1 PLOT BUSBAW/TOP , 2 A A Z O w N Z ELECTRICAL PANEL gUSBAR, 200 A MAIN > 9N Y PV-1 SCALE: NTS BREAKER � Y co � v LICENCE NUMBER WLo F— NASSAU COUNTY Q Q O 385 W JOHN ST UNIT 100, 2 2 100, HICKSVILLE, NY SITE DETAILS ADDRESS 11801 0 SUFFOLK COUNTY ASHRAE EXTREME LOW 5.00' F 3125 VETERANS DRWN K.VIANA MEMORIAL HWY, G, THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A ASHRAE 2% HIGH 87.80' F CHKD I E.IM RONKONKOMA, NY 11779 PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE DATE 1 12/01/2022 WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A CLIMATE DATA SOURCE TMY3 SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL SCALE: PHONE NUMBER 516-418-2131 WIND SPEED 135 MPH NTS INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS AND NOTHING IN THIS CONTACT EMAIL info@nystatesolar.com DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS WIND EXPOSURE B TITLE. ADDRESS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS CATEGORY PROJECT SUMMARY CONTRACTOR DOCUMENT. GROUND SNOW LOAD 30 PSF SIGNATURE Pv_ GENERAL NOTES EQUIPMENT LIKELY TO BE WORKED UPON OF NEW WHILE ENERGIZED SHALL BE INSTALLED IN F W y 1 LOCATIONS THAT SATISFY MINIMUM WORKING 0 TT CLEARANCES PER NEC 110.26 Is'-1" 13'-5" * o [193„] [Is�'� o N CONTRACTOR SHALL USE ONLY COMPONENTS 2 LISTED BY A NATIONALLY RECOGNIZED L�j TESTING LABORATORY FOR THE INTENDED USE CONTRACTOR IS RESPONSIBLE FOR `r�� 084951 M FURNISHING ALL RELATED EQUIPMENT, 0, 0 N u 3 CABLES, ADDITIONAL CONDUITS, BOXES, �OFESSIONP RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND _ OPERATIONAL PV SYSTEM so'-a" zs'-s- THE SYSTEM SHALL COMPLY WITH NEC [364"] [354"] ARTICLE 690, ALL MANUFACTURERS LISTING 4 AND INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE _ AUTHORITY HAVING JURISDICTION'S (AHJ) E APPLICABLE CODES z0 . Z WHERE DC PV SOURCE OR DC PV OUTPUT E Y `m CIRCUITS ARE RUN INSIDE THE BUILDING, THEY o SHALL BE CONTAINED IN METAL RACEWAYS, LL 7 N O TYPE MC METAL-CLAD CABLE, OR METAL THERESA DRIVE 5 ENCLOSURES FROM THE POINT OF o 0 PENETRATION INTO THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS, PER NEC 690.31(G) i U L Z cn > 1 SITE PLAN Z PV-2 SCALE: 1/32" = V-0" z 0 R324.6 ROOF ACCESS AND PATHWAYS-ROOF ACCESS, PATHWAYS, AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R.324.6.2.1.ACCESS AND MINIMUM Q Y j Lo SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS,AND TO Z U Q PROVIDE EMERGENCY EGRESS FROM THE ROOF. 0 Jz � } LL O W z EXCEPTIONS: Z 1. DETACHED, UNINHABITABLE STRUCTURES, INCLUDING BUT NOT LIMITED TO DETACHED GARAGES, PARKING SHADE STRUCTURES, CARPORTS, SOLAR TRELLISES AND SIMILAR STRUCTURES, SHALL NOT BE Of > 0 a v REQUIRED TO PROVIDE ROOF ACCESS. W Y F- 2. ROOF ACCESS, PATHWAYS AND SETBACKS NEED NOT BE PROVIDED WHERE THE BUILDING OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE EMPLOYED. LU �n 3. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (17-PERCENT SLOPE)OR LESS. 00 < cc 0 (NY) R324.6.1 PATHWAYS -NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDE AND NOT LESS THAN 36 INCHES (914MM)WIDE, SHALL BE PROVIDED ON ALL Z) BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 C) INCHES WIDE (914MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND DRWNK.VIANA ADJACENT ROOF PLANES. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS CHKD E.IMHKD VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS, RAFTER, OR OTHER SUCH FRAMING SYSTEM THAT DATE 12/01/2022 SUPPORTS THE PATHWAY. SCALE:: EXCEPTION:ACCESS PATHWAYS SHALL NOT BE REQUIRED ON ROOF SLOPES CONTAINING PHOTOVOLTAIC MODULES, PANELS, OR AN ARRAY WHERE THE OPPOSING OR ADJACENT ROOF SLOPE IS AN ACCESS NTS ROOF. TITLE: (NY) R324.6.2 SETBACK AT RIDGE- PHOTOVOLTAIC ARRAYS SHALL NOT BE LOCATED LESS THAN 18 INCHES (457MM) FROM A HORIZONTAL RIDGE. SITE PLAN PV-2 BUILDING REVIEW NOTE TOWN BUILDING PLANS EXAMINER HAS RECEIVED OF NE THE ENCLOSED DOCUMENT FOR MINIMUM E' wy0 ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED IN THE BUILDING AND/OR o RESIDENTIAL CODE OF THE STATE OF NEW YORK. * � THIS REVIEW DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE. THAT RESPONSIBILITY IS c� GUARANTEED UNDER THE SEAL AND SIGNATURE 2 v ROOF AREA 1 OF THE NEW YORK STATE LICENSED DESIGN `rF 084951 (� 261'TRUE;23'TILT; Q Cr 5.1/12 PITCH PROFESSIONAL OF RECORD. THAT SEAL AND 16"O. RAFTERC.SPACING ��4FESSIONP� 30'-4" SIGNATURE HAS BEEN INTERPRETED AS AN 6"O. (30�4 MODULES [364"] ATTESTATION THAT, TO THE BEST OF THE CHMENTS TYPE:SNAPNRACK SPEEDSEAL LICENSEES BELIEF AND INFORMATION THE WORK IN DOCUMENT IS: *ACCURATE •CONFORMS WITH GOVERNING CODES N N ■ I APPLICABLE AT THE TIME OF THE SUBMISSION 00 •CONFORMS WITH REASONABLE STANDARDS = rI OF PRACTICE AND WITH VIEW TO THE SNAPNRACK SYSTEM E SAFEGUARDING OF LIFE, HEALTH,PROPERTY ■ (TYPICAL RAIL ACROSS j�■ � i EACH ROW OF ARRAY) AND PUBLIC WELFARE IS THE RESPONSIBILITY 0 ONLY TWO SHOWN OF THE LICENSEE Y d o —� FOR CLARITY d x O> o LL� JIM LL �N O N M� NOTE W 0 1/2'SPACING BETWEEN o 0 ROWS AND COLUMNS c ROOF AREA 2 •AN 18"WIDE CLEARING (FREE OF SOLAR o�> 261°TRUE;22'TILT; 4.8112 PITCH EQUIPMENT)SHALL BE PROVIDED ALONG AT a o 2'x6"RAFTER LEAST ONE SIDE OF THE ROOF RIDGE ON THE N 3 > 16"O.C.SPACING 29'-6" SAME SIDE AS THE SOLAR EQUIPMENT OR ON i 6 MODULES [354"] ( ACHMENTS ANOTHER SIDE OF THE RIDGE THAT DOES NOT TYPE:SNAPNRACK SPEEDSEAL T _ _-----------_�__ HAVE SOLAR EQUIPMENT ON IT. SUFFICIENT ACCESS PATHWAYS, ROOF ACCESS POINTS, Z ! ! AND GROUND ACCESS AREAS SHALL BE 0 ^Ie j j I i PROVIDED IN ACCORDANCE WITH THE 2020 _ N NYS RESIDENTIAL CODE. Q U-) •ROOF SHALL HAVE NO MORE THAN A SINGLE �E 0 W O') � � ! LAYER OF ROOF COVERING IN ADDITION TO z_ U o E i THE SOLAR EQUIPMENT. 0 —� z m -- •INSTALLATION OF SOLAR EQUIPMENT SHALL BE Z O LLl N Z FLUSH-MOUNTED, PARALLEL TO AND NO MORE > N Y THAN 6-INCHES ABOVE THE SURFACE OF THE W Y ROOF. 2 } •WEIGHT OF THE INSTALLED SYSTEM SHALL O Q O m NOT EXCEED MORE THAN 5-PSF. •ANY PLUMBING VENTS ARE NOT TO BE CUT OR D COVERED FOR SOLAR EQUIPMENT U INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A DRWN K.VIANA CHKDPLUMBING PERMIT AND INSPECTION. DATE 12 DATE /01/2022 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET SCALE: THE MINIMUM DESIGN STANDARDS FOR BUILDING NTS AND OTHER STRUCTURES OF THE ASCE 7-10, 2020 TITLE: rl_'� NYs RESIDENTIAL CODE. ATTACHMENT PLAN ATTACHMENT PLAN PV-3 SCALE: 3/32" = 1'-0" PV-3 SNAPNRACK,ADJUSTABLE END CLAMP. SELECT TO MATCH MODULE HEIGHT 1/1"MODULE SPACING ROOF STRUCTURE SNAPNRACK,MID CLAMP. OF NEW SELECT MATCH PV MODULE,TYP. R 1: 2" x 6" @ 16" O.C. C T T MODULELE HEIGHT RAFTER SPACING: R2: 2"x 4" @ 16" O.C. , * O PV MODULE,TYP. SNAPNRACKULTRA RAIL PV MODULE FRAME,TYP. SNAPNRACK,UNIVERSAL END CLAMP. R1: 13'-5" r Ui o n MO ACTUALSPAN:DULE HEIGHT AGNOSTIC AND R2: 13' 1" \ SNAPNRACK,ULTRA RAIL HIDDEN BENEATH MODULES 2S 0 DETAIL A: DETAIL B: DETAIL C: SNAPNRACK,ULTRA RAIL SHEATHING: PLYWOOD FAA 084951 SNAPNRACK, ADJUSTABLE END CLAMP SNAPNRACK, MID CLAMP SNAPNRACK, UNIVERSAL END CLAMP PV MODULE,TYP. COLLAR TIES: N/A FES53 A a _ TYPE/LAYERS: ARCH / 1-LAYER SNAPNRACK,ULTRA RAIL "RAIL END OVERHANG" "RAIL SPAN"DISTANCE BETWEEN DISTANCE FROM RAIL END CENTERS OF TWO ROOF ATTACHMENTS SNAPNRACK ROOF ATTACHMENT, TO OUTER ROOF ATTACHMENT CENTER. VARIES WITH ROOF TYPE <j = NOT TO EXCEED 34%OF ALLOWABLE SPAN m m STRUCTURAL MEMBER d �fz UAL SNAPNRACK,MID CLAMP. = SNAPNRACK,ADJUSTABLE o END CLAMP.SELECT TO SELECT TO MATCH MODULE HEIGHT U. c MATCH MODULE HEIGHT SNAPNRAC ULTRA RAIL "MODULE OVERHANG. o K. DISTANCE FROM RAIL SIDE TO MODULE EDGE. NOT TO EXCEED 25%OF MODULE LENGTH OR PV MODULE,TYP. MODULE MANUFACTURER RECOMMENDATIONS 9 9 z= n _ z V L Q� � QN z 2 SNAPNRACK,ULTRA RAIL END CAP,OPTIONAL Z O C14 ROOFING MATERIAL, ~ COMP SHINGLE SHOWN,TYP. � � W j 0) ROOF SHEATHING AND s= I— UNDERLAYMENT MATERIAL,TYP. Z_ C) o STRUCTURAL MEMBER, SNAPNRACK ROOF ATTACHMENT,VAIRES WITH LL J W N Z WOODEN RAFTER SHOWN TYP. ROOF TYPE.REFER TO SPECIFIC"ATTACHMENT DETAIL" z O FOR ATTACHMENT&WATERPROOFING DETAILS — > Y LLI Y w O CQC � � (v — MID CLAMP ASSEMBLY G / 6-12 AWG BARE 5/16"-18 SS BOLT / COPPER WIRE SS SPLIT LOCK WASHER ( — (TORQUE TO 16 FT-LBS) (� NOTE: \ 1.ALL HARDWARE IS INCLUDED FROM MANUFACTURER SNAPNRACK 2,A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY DRWN K.VIANA / _ \ GROUND LUG CONTINUOUS ROW OF MODULES CHKD E.IM SS BONDING PIN I ' DATE 12/01/2022 1 /� \ 3.GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL \ / I CHANNEL NUT 4.GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR SCALE: MODULE PERPENDICULAR TO RAIL / FRAME \� \ / 5.ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE NTS RAIL TITLE. SS BONDING RAIL ATTACHMENT DETAILS PINS CHANNEL NUT PV-4-1 STRING ATTIC EXTERIOR WALL 01 N E W 1 3 5 i METER NUMBER:98308018 C T r OP * o 0 1 2 9 10 To UTILITY . . . . . . . . — SOLARDECK ——_ O UTILITY METER STRING OF v�O 084951 (10)REC405AA PURE-R MODULES I ''90FE S S I0 WITH P485 DC OPTIMIZER I I —— EXTERIOR WALL I STRING ATTIC c I EGC ATTACHED 6 I M3P NOTE: TO RAIL 2 THIS MAIN DISTRIBUTION PANEL HAS A 200 AMP I RATED BUS WITH 200 AMP 200A MAIN BREAKER I I MAIN i I 200 A BUS•120%=240 A 1 2 9 10 LOADS 2400 A-200 A MAIN=40 A . . . . . . SOLARDECK i I THE MAXIMUM BACK FEED O • ——— LL�L CIRCUIT BREAKER SIZE IS ____ _______ ______ 40 AMP PER NEC201740V2P SECTION 705.12(Ox2N3)(0)STRING OF CONNECTION WITH } O (10)REC405AAPURE-RMODULES I E ---� LOAD SIDE TAP PER NEC a) WITH P4B5 DC OPTIMIZER �J — ---- — -------------- — SECTON 230.82(S) z 2 Z O EGC ATTACHED �__ i O`j Y TO RAIL y 7 U. N Lz L, SOLAR EDGE TECHNOLOGY EGC/GEC I SE7600H WITH a DC DISCONNECT SWITCH SYSTEM DETAILS 32.00 AMP LOAD ISTRING INVERTER --GROUND ROD 32.D0 AMP x 1.25 CONT DUTY=40.00 AMP(HARE AMPACITY MIN.) .0 Z Z NEW GRID-INTERACTIVE `0' `Z z . DESCRIPTION PHOTOVOLTAIC SYSTEM w 3.N WITH NO BATTERY STORAGE DC RATING OF SYSTEM 8,100 W AC RATING OF SYSTEM 7,600 W Z INVERTER(S) (1)SOLAR EDGE TECHNOLOGY 0 sE7sooH CONDUIT AND CONDUCTOR SCHEDULE I'_ N Lo INVERTER TYPE STRING INVERTER TAG CONDUCTOR TYPE CONDUCTOR NUMBER OF CONDUIT TYPE CONDUIT RUN 2E U) w a) GAUGE CONDUCTORS SIZE LENGTH z U Q �- MODULE (20)REC405AA PURE-R 1 PV WIRE 10 2 N/A N/A 40'-0" 0 :1z co } BARE COPPER GND IN FREE AIR 6 1 N/A N/A 25'-0" z 0 Q N Z PV WIRE 10 2 N/A N/A 40'-0" > 0 V� 2 BARE COPPER GND IN FREE AIR 6 1 N/A N/A 25-0" W L � THWN-2 10 2 LFMC&PVC 1" 40'-0" O < C 00 GENERAL NOTES 3 EGC 10 1 PVC SCH.40 1" 40'-0" c i 1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION 4 THWN-2 10 2 LFMC&PVC 1" 40'-0" U INSTRUCTIONS EGC 10 1 PVC SCH.40 1" 40'-0" 2. ALL PV EQUIPMENT SHALL LISTED BY RECOGNIZED TESTING LAB I DRwN K.VIANA 3. WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION,BREAKER SHALL NOT READ LINE AND LOAD THWN-2 10 2 PVC SCH.40 1" 30'-0", CHKD E.IM 4. WHEN A BACKFEED BREAKER IS METHOD OF UTILITY INTERCONNECTION,THE BREAKER SHALL BE INSTALLED AT THE 5 DATE 12/01/2022 EGC 10 1 PVC SCH.40 1" 30'-0" OPPOSITE END OF THE BASS BAR OF THE MAIN BREAKER SCALE: 5. WORK CLEARANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2), THWN-2 10 2 PVC SCH.40 1" 30'-0" 110.269(A)(3) s NTS 6. ALL EXTERIOR CONDUITS,FITTINGS AND BOXES SHALL BE RAIN TIGH AND BE MIN.NEMA 3R RATED IEGC 10 1 PVC SCH.40 1" 30'-0" 7. AC AND DC GROUNDING CONDUCTORS PER NEX ARTICLE 690.43(A)THRU(F)CONNECTED AS PER 690.45(A),690.46 AND TITLE: THWN-2 6 3 PVC SCH.40 1" 20'-0" SIZED PER 250.112 7 3—LINE DIAGRAM 8. PROVIDE EXPANSION JOINTS AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC REQUIREMENTS EGC 6 1 PVC SCH.40 1" 20'-0" 9. PROVIDE LABEL,PLACARD AT EXISTING UTILITY CONNECTION WITH"WARNING-CUSTOMER OWNED ELECTRICAL GENERATION EQUIPMENT CONNECTED"WITH APPROPRIATE HAZARD AND OUTPUT RAITING OF PV SYSTEM PV-5 DC RACEWAYSARN1PHOTOVOLTAICLABELING NOTES 1"""' V HOTOVOLTAIC POWER SOURCEDISCONNECT O ALL PLAQUES AND SIGNAGE REQUIRED BY F NEW y OSEE NOTE NO. 6 NEC ARTICLE AC SOLAR DISCONNECT, NEC 2017 NEC WILL BE INSTALLED AS REQUIRED �C C Tr 690.31(G)(3) © ARTICLE 690.14(C)(2) LABELS, WARNING(S)AND MARKING SHALL * o y COMPLY WITH ANSI Z535.4, WHICH REQUIRES TRANSITION BOX THAT DANGER, WARNING,AND CAUTION ARNING , , •LTAIC SYSTEM SIGNS USED THE STANDARD HEADER C= ELECTRIC SHOCK HAZARD 2 COLORS, HEADER TEXT, AND SAFETY ALERT `f'F 084951 O O EQUIPPED WITHSYMBOL ON EACH LABEL. THE ANSI �AoP DO NOT TOUCH TERMINALS OF N TERMINALS ON BOTH THE LINE AND STANDARD REQUIRES A HEADING THAT IS AT ESSIO LOAD SIDES MAYBE ENERGIZED - RAPID SHUTDOWN LEAST 50%TALLER THAN THE BODY TEXT, IN IN THE OPEN POSITION ACCORDANCE WITH NEC ARTICLE 110.21(B)i AT THE EACH DISCONNECTING SEE NOTE NO. 7 NEC ARTICLE A PERMANENT PLAQUE OR DIRECTORY SHALL INVERTER O MEANS FOR PHOTOVOLTAIC O 690.56(C) BE INSTALLED PROVIDING THE LOCATION OF EQUIPMENT. NEC ARTICLE THE SERVICE DISCONNECTING MEANS AND O O ® 690.17(4) 3 THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME _ i LOCATION IN COMPLIANCE WITH NEC INVERTER OUTPUT CONNECTION 690.56(B) LWARNING r 1 DO NOT RELOCATE THIS v E WHERE THE INVERTERS ARE REMOTELY 0 OVERCURRENT DEVICE x `m o DISCONNECT SWITCH ELECTRIC SHOCK HAZARD LOCATED FROM EACH OTHER, A DIRECTORY o> THE DC CONDUCTORS OF IN SHALL BE INSTALLED AT EACH DC U. THIS PHOTOVOLTAIC SYSTEM Q SOLAR BREAKER(MSP) NEC PHOTOVOLTAIC SYSTEM DISCONNECTING O5 6 ARE UNGROUNDED AND O ARTICLE 705.12(D)(2)(3)(B) MEANS, AT EACH AC IS CONNECTING MEANS, o O MAY BE ENERGIZED 4 AND AT THE MAIN SERVICE DISCONNECTING a MEANS SHOWING THE LOCATION OF ALL AC OAT EACH DEVICE WHERE AND AND DC PHOTOVOLTAIC SYSTEM ENERGIZED, UNGROUNDED DISCONNECTING MEANS IN THE BUILDING, IN o i CIRCUITS MAY BE EXPOSED DUAL POW ER SUPPLY Q' MAIN SERVICE PANEL ACCORDANCE WITH NEC 690.4(H) DURING SERVICE. NEC ARTICLE ;t SOURCES:UTILITY GRID AND w3.y PV SOLAR ELECTRIC SYSTEM Q 690.35(F) `-- — THE MATERIALS USED FOR MARKING MUST Z ,_ O © O ® O BE WEATHER RESISTANT, IN COMPLIANCE O ANY AC ELECTRICAL PANEL 5 WITH CBC 511.3.1. IT IS RECOMMENDED THAT • • • •• • THAT IS FEED BY BOTH THE UL 969 BE USED AS STANDARD TO '� O • UTILITY AND THE DETERMINE WEATHER RATING Z • • PHOTOVOLTAIC SYSTEM (MSP) LABEL(S)WITH MARKING "WARNING: O •• NEC ARTICLE 705.12(D)(4) PHOTOVOLTAIC POWER SOURCE"SHALL BE Q Y a) LLo •• •• LOCATED EVERY 10 FEET OF EACH DC O z U Q DC DISCONNECT, NEC ARTICLE RACEWAY AND WITHIN ONE FOOT OF EVERY ® 690.53 (FOR REFERENCE ONLY) CAUTION : 6 TURN OR BEND AND WITHIN ONE FOOT IL Q W z ABOVE AND BELOW ALL PENETRATIONS OF z POWER TO THIS BUILDING IS ALSO ROOF/CEILING ASSEMBLIES, WALLS AND > Y • •• • • • BARRIERS. THE LABEL SHALL HAVE 3/8"TALL W Y � _� •• • • • • ' • LETTERS AND BE REFLECTIVE WITH WHITE W Lo >_ TEXT ON A RED BACKGROUND 0 00 LABEL(S)WITH MARKING "PHOTOVOLTAIC •• ,� ►, SYSTEM EQUIPPED WITH RAPID SHUTDOWN." •. •••, • �� SHALL BE LOCATED U O �''•.,�t 7 POINT-OF-INTERCONNECTION OR AT MAIN DRWN K.VIANA AC DISCONNECT, NEC ARTICLE �.•��.; SERVICE DISCONNECT. THE LABEL SHALL CHKD E.IM '•:�......., HAVE 3/8"TALL LETTERS AND BE REFLECTIVE DATE 12/01/2022 690.54 (FOR REFERENCE ONLY) . WITH WHITE TEXT ON A RED BACKGROUND SCALE: NTS POINT OF INTERCONNECTION OR AT MAIN 1 O SERVICE DISCONNECT(MSP), NEC ARTICLE TITLE. SAFETY ILABEIL--�l 690.54 (FOR REFERENCE ONLY) S P V -6 SOLAR'S MOST TRUSTEDD RE C ym RE[',.AL Ell RE-R -5� ER,,�ll .9 r � 1 q, y.a PRODUCT SPECIFIC-7-AT �'I _ - a d - ' � '"tea. vc•'' 1. Fa 4j 1 am]Bill .. 410 . 20.7 wF'T WN�HAK FY ,•. 1f25 YEAR EFFICIENCY LEAD-FREE 22.37. ELIGIBLE ROHS COMPLIANT PERFORMANCE *t RE[ ALPHA PURE-R 5ERIE5 REC PRODUCT 5PEEIREATIONS '"'-q'_."" wwlJ'."',y'."'""'"Y:..,.'„'""'•..,,:�°+, 1730375I68.1S0.11 ...,....:.a.«.....,,................. ..._,...s5 ...r:.:.....K..,.....:..e.......:..i..:............cJ'"c-.:,:d 8e0I34b1 � 475 n6.71 Cell type: 80 half-cut REC bifacia[,heterojunction cells with lead-free,gapless technology Glass: 0.13in(3.2mm)solarglass with antFreflective surface treatment in accordance with EN 12150 i =oo,i Backsheet: Highly resistant polymer(black) - 1700 I671 1700I671 Frame_ Anodized aluminum(black) _ + 4-part,4 bypass diodes,lead-free Junction box: IP68 rated,In accordance with IEC 62790 Connectors: StaubliMC4PV-KBT4/KST4(4mm2) q2 in accordance with IEC 62852,IP68 only when connected io 431°9,1 Cable: 12AWG(4mm2)PVwire,67+67in(1.7+1.7m) 0 7osasr- in accordance withEN50618' Iaemoz�,. roremip:um , Dimensions: 68.1x44.Oxl.2in(20.77ft2)/173Ox1118x3Omm(1.93 m2) } �� s9ax3I234to.121 -45 I1s1 22510.91 Weight: 47.4lbs(21.5 kg) Origin: Made in Singapore Measurements in inches[mml )" ELECTR#CAL DATA:• Pibduct£oBe::R6£Xxx1RA'PtIRE-R CERTlF1CATEOY�S % Power Output-PmAx(Wp) 400 410 420 430 IEC 6]215:2016,IE_C 61730:2016,UL 61730.- WattClassSorting-(W) 0/+10 0/+10 0/+10 0/+10 -- - IEC62804 PID IEC 61701 Salt Mist Nominal Power Voltage-VMpp(V) 48.8 49.4 50.0 50.5 IEC62716 Ammon iaResistance v Nominal Power Current-IMpp(A) 8.20 8.30 8.40 8.52 UL61730 Fire Type Class 2 in Open Circuit Voltage-Voc(V) 58.9 59.2 59.4 59.7 IEC62782 Dynamic Mechanical Load --- IEC61215-2:2016 Hailstone(35mm) Short Circuit Current Isc(A) 8.73 8.81 8.89 8.97 IEC62321 Lead-freeacc.to.ROHSEU863/2015 PowerDensity(W/ftz) 19.26 19.74 20.22 20.7 ISO 14061,ISO 9001,IEC 45001,IEC 62941 Panel Efficiency(%) 20.7 21.2 21.8 22.3 v oe °®- f Power Output-PmAx(Wp) 305 312 320 327 6 teeo-r.ee NominalPowerVoltage-VMpp V 460 46.6 47.1 47.6 �" o _ . _ [TEMPERATYRER%1TIPIGS';µx w rr y . 1 C) Nominal Power Current-1,,pp(A) 6.64 6.70 6.78 6.88 Nominal Module Operating Temperature: 44°C(±2°C) . z 0 enCircuitVolta e-V (V) 55.5 55.8 56.0 56.3 0 P g oc Temperature coefficient of PMAx' -0.26/a/°C Short Circuit Current-Isc(A) 7.05 7.12 7.18 7.24 ;Temperature coefficient of Voc: -0.24%/°C Values at standard test conditions(STC:air mass AMI.5,irradiance10.75W/sgft(1000W/m'),temperature 77°F(25°C),basedona production spread Temperature[oefficientofl 0.04%/°C with atoleranceofP.,Va&15Ct3%within one watt class.Nominal module operatingtemperature(NMOT:airmassAM1.5,irradiance800W/m2, sc temperature 68°F(20°C),windspeed 33 ft/s 0 m/s).'Where xxx indicates the nominal power class(P.)at STC above. 'The temperature coefficients stated are linear values MAXIMUM.ftAT1N65";.`" >?- .,y. D 'WAE RANIY: 'Y " ;r„ z IIELIVERI'INFU I:...a,,..,.,,.�.• t..._.. �,�.............m. ...._ ,:�i::.:�y ........_S Operational temperature: -40...+85°C Standard RECProTrust Panels per pallet: 331 e: 1000V - S stemvolta Installed er40ftGP/hi y - - 8 Certified Solar Professional No Yes Yes Panels P 8hcubecontainer. 858(26 Pallets ) Test load(front): +7000Pa(1461bs/ft2)', System Size All 42SkW25500kW Panels per 53 ft truck: 858(26pallets) Test load(rear): -4000Pa(83.5lbs/ftz)' Product Warranty(yrs) 20 25 25 Series fuse rating: 25A, ,Power Warranty(yrs) 25 25 25 1 LOW,LIGHT BEHAVIOUR' o Reverse current: 25A Labor Warrant 0 25 10 Typical low irradiance performance of module at STC: Warranty See installation manual for mountin instructions. Power inYear1 98% 98% 98% ;\ gg , --------------------- , Design load-Test load/1.5(safetyfactor) Annual Degradation 0.25% 0.25% 0.25% ` Power in Year 25 92% 92% 92% w See warranty documents for details.Conditions apply ----------------------------- ----- a Availablefrom: ° �Irradiance(W/mI m N N m O rD [Y O rV N 0 Founded in 1996,REC Group is an international pionee ring solar energy companydedicated to em powering Consumers with clean,affordable so la r power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar panels it manufactures. ❑� r a Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. www.recgroup.com Single Phase Inverter Z • C with HD-Wave Technology m for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US SE760OH-US / SE1000OH-US / SE1140OH-US m L4n ® a �o o L® solar,3G'C' �.;ii���, © . solar= 4 t O Optimized installation with HD-Wave technology / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small, lightweight, and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Optional: Faster installations with built-in consumption metering (1%accuracy) and / Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5%accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com solar=@9 / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US MODEL111 811 111 .00O .11 1111 411 APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom:Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.50r Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output _ 16 - 24 - - 48.5 A Current @208V Power Factor 1,Adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2) 8.5 10.5 1 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V- - 9 1 - 13.5 - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @ 240V 98.5 @ 208V Nighttime Power Consumption <2.5 W 11)For other regional settings please contact SolarEdge support (2)A higher current source may be used;the inverter will limit its input current to the values stated .e / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Metering,ANSI C12.20 Consumption metering Optionall'l Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown-NEC 2014,NEC Automatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020,690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm Weight with Safety Switch 22110 1 25.1/11.4 1 26.2/11.9 38.8/17.6 lb/kg Noise <25 1 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+6001 T/-C Protection Rating NEMA 4X(Inverter with Safety Switch) (3)Inverter with Revenue Grade Meter P/N:5ExxxxH-US000BNC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SEx)=H-US000BNI4.For consumption metering,current transformers should be ordered separately:SEACT0750-20ONA-20 or SEACT0750-400NA-20.20 units per box (4)Full power up to at least 50'C/1227;for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring Grid r T Y Y r "r Shielded CATSe cable CT Li N L2 -- ----- ------ - N !%E_ L2 t=J 00 !N1 AC Conduit m SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All RoH S other trademarks mentioned herein are trademarks of their respective owners.Date:12/2020ND1/ENG NAM.Subject to change without notice. SnapNrack- UR-40 Solar Mounting Solutions UR-60 Ultra Rail The Ultimate Value in Rooftop Solar Industry leading Wire Mounts available for all Management Solutions roof types Single Tool Installation All SnapNrack Module re Clamps & Accessories are • • • • le with both raiii profiles RESOURCES snapnrack.com/resources DESIGN snapnrack.com/configurator WHERE TO BUY snapnrack.com/where-to-buy SnapNrack A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profiles; UR-40 is a lightweight rail profile that is suitable for most geographic regions and maintains all the great features of SnaoNrack rail, while UR-60 is a heavier duty rail profile that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps :. :.. { and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install ys • Industry best wire management offering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard Heavy Duty UR-60 Rail • UR-60 rail profile provides increased span capabilities for high wind speeds and snow r''J r' loads • Taller, stronger rail profile includes profile- ° specific rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience Quality. Innovative . Superior. SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. . • O 2019 • •lar Mounting Solutions.All -•