Loading...
HomeMy WebLinkAbout51444-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE 40 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51444 Date: 12/05/2024 Permission is hereby granted to: GH Assets 2 LLC 350 Moffit Blvd FI 2 Islip, NY 11751 To: construct additions and alterationsto an existing accessory building as applied for per SCHD approval. Premises Located at: 3420 Rocky Point Rd, East Marion, NY 11939 SCTM#21.-4-8 Pursuant to application dated 10/11/2024 and approved by the Building Inspector. To expire on 12/05/2026. Contractors: Required Inspections: Fees: Accessory-Addition/Alteration $552.00 CO Accessory $100.00 Total $652.00 --V"'Wilding Inspector � "tee TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 Iitt 8Nv sorri'hqidloNV11[bLp Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only 3 V q � r PERMIT NO.a_., I 44 Building Inspector: CT 1 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. r7,.4 U..n,I Date:9-17-24 OWNER(S)OF PROPERTY: Name:GH ASSETS 2 LLC SCTM#1000-021.00-04.00-008.000 Project Address: 3420 ROCKY POINT RD, EAST MARION, NY 11939 Phone#:516 903-4516 Email:nicole@gemhunterpropertysolutions.com Mailing Address: 6 KIMBERLY AVE. FARMINGVILLE, NY 11738 CONTACT PERSON: Name:Nicole Cooper Mailing Address: 6 KIMBERLY AVE. FARMINGVILLE, NY 11738 Phone#:516 903-4516 Email:nicole@gemhunterpropertysolutions.com DESIGN PROFESSIONAL INFORMATION: Name:Curtis Taufman, Architect Mailing Address:6270 Northern Blvd., East Norwich, NY 11732 Phone#:516 427-1602 Email:curtisdesigngroup@verizon.net CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ■Alteration NRepair ❑Demolition Estimated Cost of Project: ❑Other, $35,000 Will the lot be re-graded? ❑Yes ONO Will excess fill be removed from premises? ❑Yes ■'No Existing Barn and Shed renovation conversion to Pool House 1 PROPERTY INFORMATION Existing use of property:Residencial Intended use of property:Residencial Zone or use district in which premises is situated„ Are there any covenants and restrictions with respect to R40 this property? ❑Yes ■No IF YES,PROVIDE A COPY. Check BOX After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name):Curtis Taufman, Architect Authorized Agent ❑Owner Digitally signed by Curtis Taufman Signature of Applicant: Curti an Date:2024.10.10 21:02:28-04,00, Date:9-17-24 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Curtis Taufman being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of l/G-t���lr 20 tai' 4AZEY L. t7 YFR NOTARY PUBLIC,STATE OF NEW YORK NO.01 DW6306900 PROPERTY OW of AUTHORIZATION OQ LIFIED IN SUFFOLK COUNTY" Where theapplicant OWNER AUn Hw _ ` p he owner) COMMISSION EXPIRES�IUN 00,2 Nicole Cooper residing at 6 Kimberly Ave., Farmingville NY, 11738 Curtis Taufman, Architect do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. A)VIL9/17/2024 Owner's Signature Date Nicole Cooper Print Owner's Name 2 Buildigg Department Agplication AUTHORIZATION (Where the Applicant is not the Owner) I, Nicole Cooper residing at 8 LIMBERLY AVE. FARMINGVILLE ......... ........ (Print property owner's name) (Mailing Address) NY 11738 do hereby authorize CURTIS TAUFMAN,ARCHITECT _. ._.._............................................... ._._. (Agent) 6270 Norhtern Blvd.,East Norwich,NY 11732 to apply on my behalf to the Southold Building Department. k6k� 09/17/2024 (Owner's Signature) (Date) Nicole Cooper (Print Owner's Name) Generated by REScheck-Web Software 0 IAL�(J Compliance Certificate Project Pool house 3420 Rocky Point Rd. East Marion, NY Energy Code: 2018 IECC Location: Suffolk County, New York Construction Type: Single-family Project Type: Alteration Project SubType: None Orientation: Bldg. faces 270 deg. from North Climate Zone: 4 (5999 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: true Construction Site: Owner/Agent: Designer/Contractor: 3420 Rocky Point Rd, Nicole Cooper East Marion, NY Gem Hunter 516903-4516 nicole@ghpre.com Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope eGross Area Cavity Cont. Prop. Req. Prop, Req. Perimeter Ceiling: Flat Ceiling or Scissor Truss 447 47.0 0.0 0.026 0.026 12 12 Wall: Wood Frame, 16"o.c. 825 15.0 4.0 0.057 0.060 41 43 Orientation: Unspecified Door Copy: Glass Door(over 50%glazing) SHGC: 0.40 84 0.300 0.320 25 27 Orientation: Unspecified Window:Wood Frame SHGC: 0.40 19 0.300 0.320 6 6 Orientation: Unspecified Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 1 of10 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the ma a ory r qui errs nts listed in the REScheck Inspection Checklist. CURTIS TAUFMAN, ARCHITECT 12-2-24 Name-Title Signature Date Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 2 of10 REScheck Software Version : REScheck-Web n�r Inspection Checklist Energy Code: 2018 IECC Requirements: 97.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section I Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions 103.1, Construction drawings and il / Complies Requirement will be met. 103.2 documentation demonstrate ,,, ❑Does Not [PR111 ;energy code compliance for the g ;��� , i ;❑Not Observable 4 'building envelope.Thermal envelope represented on /r „ ❑Not Applicable construction documents. 103.1, Construction drawings and , j�/ '��„ /� ❑Complies Requirement will be met. 103.2, :documentation demonstrate ❑Does Not 403.7 ;energy code compliance for '9" [PR3]1 lighting and mechanical systems ° ' i �, ❑Not Observable . :Systemsservingmultiple �r��; n ��� "', '❑Not Applicable J i i i :dwelling units must demonstrate °� compliance with the IECC :Commercial Provisions. 302.1, I Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual 5 based T Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: - Cooling: ❑Not Observable Manual J or other methods 1 Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2`1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 3 of10 Sectlonw # Foundation inspection _L_�o nplies? oowr + nts1"A^ss+iuimption ate .10 3032A A protective covering is Installed to (rlCompi'ies Requirement will be met. [F 11]2 protect exposed exterior Insulation Zboes Not and extends a minimum of 6 in. below ; grad. .®Not Observabie i []Not Applicable 463.9 Snow-and ice-melting system controls f1Complies Exception:Requirement is not applicable. [FO12)2 Installed. ®Goes Not t-]Not observable ONot.Applicable Additional Comments/Assumptions: 1 I High Impact.(Tier 1.) 2 1 Medium Impact(Tier 2) 3 Low Impact("Tier 3) Project Title: Pool house 3420 Rocky Point Rd, East Marion, NY Report date: 12/02/24 Data filename: Page 4 of10 Section ' Plans Verified Field Verified # . Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies ,See the Envelope Assemblies 402.3.1, average). p❑Does Not table for values. 402.3.3, 402.5 UNot Observable [FR2]1 UNot Applicable 303.1.3 U-factors of fenestration products , �% ;❑Complies Requirement will be met. [FR4]1 :are determined in accordance ;❑Does Not ;with the NFRC test procedure or j / ❑Not Observable 'taken from the default table. ';'�� / "' r/;" �" ❑Not Applicable 402.4.1.1 IAir barrier and thermal barrier �:�, �'�;;'//�',, r,,,,, ° ❑Complies [FR23]1 installed per manufacturer's r „ / �r// ,❑Does Not Instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built /' ; ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting 'rr/�r, ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 / ❑Not Observable or has infiltration rates per NFRC ' ' ❑Not Applicable 400 that do not exceed code r r/ limits. 402.4.5 ;IC-rated recessed lighting fixtures / / ' �r ' ❑Complies Requirement will be met. i�/%i i [FR16]2 sealed at housing/interior finish /o � „ ',� /�/, �r// '/ ❑Does Not and labeled to indicate 152.0 cfm Not Observable y leakage at 75 Pa. ❑ ❑Not Applicable 403.3.1 Supply and return ducts in attics j/; ,/ ' „j��//r�/r�"' /r�%/, ❑Complies Exception: Ducts located [FR12]1 insulated >= R-8 where duct is rr/rrr i%,/,,,� ,� �,j/ //, / %❑Does Not completely inside the / �rirrr riir >= 3 inches in diameter and > �"i/,,,/,/' �„ � „r� r„ % /r " building envelope. � / r/ /� ❑Not Observable R-6 where< 3 inches. Supply and ;,� i return ducts in other portions of /„fir ��/ /„ �� ��i%///� ��r�// "; ❑Not Applicable ithe building insulated >= R-6 for / ,j„/ ,�r %i it r diameter>= 3 inches and R-4.2 / ��' /'/ """ "i�/ 'r' for< 3 inches in diameter. 403.3.2 Ducts, air handlers and filter W;,� °;❑Complies Requirement will be met. FR13]1 boxes are sealed with ❑Does Not ji//r'%Oi i%� // ' r [ oints/seams compliant with �!� '� r 'i p ', �% ' /!"/ % '% ❑Nat Observable International Mechanical Code or ��,, /� International Residential Code, as r,��/,/ �r /r ', �/ ❑Not Applicable ;applicable.403.3.5 Building cavities are not used as /j//r�f;;' `'' / ' /; r�❑Complie Requirement will be met. [FR15]3 ducts or plenums. ��,/�r r r/ r„ ❑Does Not ❑Not Observable r ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies Exception: Requirement is [FR17]2 above 105 °F or chilled fluids ElDoes Not not applicable. below 55 °F are insulated to?R- 3. I❑Not Observable i❑Not Applicable 403.4.1 °Protection of insulation on HVAC ❑Complies Exception: Requirement is [FR24]1 piping. ❑Doees Not not applicable. ❑Not Observable '❑Not Applicable 403.5.3 Hot water pipes are insulated to R R- ❑Complies Exception: Requirement is [FR18]2 >_R-3. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.6 ;Automatic or gravity dampers are t ,„gar rj, / �" " 'ter !❑Complies Requirement will be met. /iii r irr [FR19]2 i installed on all outdoor air1,0Does Not lintakes and exhausts. ❑Not Observable r i ice" ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 ILow Impact(Tier 3) Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 5 of10 Additional Comments/Assumptions: 1 Hicgh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 6 of10 section I Plans Verified Field Verified # Insulation Inspection value Value Complies? Comments/Assumptions ,we .wl 30 .1 All installed insulation is labeled L�Complies Requirement will be met. [IN131 or the installed R-values ❑roes Not provided. ;❑Not Observable ❑Not Applicable 402.1.1, ;Wall insulation R-value. If this is a R- R- ❑Complies see the Envelope Assemblies 402.2.5, mass wall with at least 1f:of the Wood j❑ Wood ❑Does Not ;table for values. 402.2.6 wall insulation on the wall [IN31'1 exterior,the exterior insulation ❑ mass ❑ mass ®Not.Observable requirement applies(FR10). Steel ❑ Steel ❑Npt,applicable 303.2 Wall insulation is installed per I A/;,, ,,,,�� ❑Complies Requirement will be met. [IN411 manufacturer's instructions. ❑Does Not Observable i� []Not Applicable cable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 7 of10 Section Plans Verified Field Verified * Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID i402.1.1, ,Ceiling insulation R-value, R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood :❑Does Not table for values. 1402.2.2, j ❑ Steel ❑ Steel ❑Not Observable 402.2.E 402.2 G Not Applicable Ceiling insulation installed per , ❑Complies Requirement will be met. 303.1.1.1, ��' 303.2 manufacturer's instructions. „�, /, , ❑Does Not [F1211 Blown insulation marked every 300 ft2. ' ����� �� ❑Not Observable ,;;�/�,,�i „� ,,,,;�r❑Not Applicable 402.2.3 Vented attics with air permeable '❑Complies Requirement will be met. [FI22]2 i insulation include baffle adjacent , , %❑Does Not Ito soffit and eave vents that 1 , ]Not Observable .extends over insulation. ❑Not Applicable 402.2.4 'Attic access hatch and door R- R- ;❑Complies Requirement will be met. [FI3]1 insulation >_R-value of the j❑Does Not j adjacent assembly. ❑Not Observable 1❑Not Applicable 402.4.1.2 ';Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 ❑Complies Requirement will be met. [FI17]1 ach in Climate Zones 1-2, and E❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 Ducts are pressure tested to s cfm/100 cfm/100 o❑Complies Requirement will be met. [FI27]1 :determine air leakage with ft2 ft2 ❑Does Not j either: Rough-in test:Total leakage measured with a ;❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system :including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Requirement will be met. [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <<=3 cfm/100 ft2 without air ;handler @ 25 Pa. For rough-in i❑Not Observable 'tests,verification may need to ❑Not Applicable °occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated mplies ',Requirement will be met. [FI24]1 by manufacturer at<=29/o of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable licable 403.1.1 Programmable thermostats /��%%° �����i ��; r�� ❑Complies 'Requirement will be met, [FI9]2 `installed for control of primary i,�e�i ,� „ El Does Not heating and cooling systems and initially set by manufacturer to ��%������ �� „ !,ly Not Observable . code specifications. i,�, %%i�i;% ;�, ��� ❑Not Applicable i„ �,. . . .. v) 403.1.2 ?`Heat pump thermostat installed ;� %� �� r �ii ❑Complies Requirement will be met. , , � , [Fl10]2 on heat pumps. �i � �/ ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 uCirculating service hot water o "�� i��iiii 'j/����, ,❑Complies !Exception: Requirement is [Fl11]2 isystems have automatic or " j�� ����� '��% 1❑Does Not not applicable. inaccessible manual controls. i ❑Not Observable Not Applicable 1 High Impact(Tier 1) 2' Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 403.6.1 All mechanical ventilation system ❑Complies Requirement will be met. [F125]2 fans not part of tested and listed ; El Does Not HVAC equipment meet efficacy and air flow limits per Table %'' ,,i�i� f ❑Not Observable i/ ri�/ R403.6.1. f ❑Not Applicable 403.2 Hot water boilers supplying heat �iiij,��� ❑Conrrplies Requirement will be met. 2 t i i i�i//iOiiiiiil i� ❑Does Not [F126] through one or two pipe heating is ��� systems have outdoor setback ❑Not Observable control to lower boiler water (temperature based on outdoor ;❑Not Applicable �temperature. 403.5.1.1 Heated water circulation systems ❑Complies Exception: Requirement is [FI28]2 have a circulation pump.The ❑Does Not not applicable. ;system return pipe is a dedicated ,,, °❑Not Observable return pipe or a cold water supply �;;/ i„ / pipe. Gravity and thermos i /�,,, %//ii '��, ❑Not Applicable syphon circulation systems are �,,,,, not present. Controls for f ° circulating hot water system / PUMPS start the pump with signal for hot water demand within the Occupancy.Controls automatically turn off the pump when water is in circulation loop 'is at set-point temperature and no demand for hot water 403.5.1.2 Electric heat traces stems '�i�i���,"� ' ��/� %'������ ,���� y ,� ,�/ � �// , / ®Complies .Exception: Requirement is [F129]2 comply with IEEE 515.1 or UL //ji �� //�i /� %„/ '�' [-]Does Not not applicable. ,515. Controls automatically adjust the energy input to the �'❑Not Observable heat tracing to maintain the % ������% , ,�� ❑Not Applicable desired water temperature in the 403.5.2 (Demand recirculation water r/��,�� ,;� Complies Exception: Requirement is [F130]2 systems have controls that ����% �� '� �� ,❑Does Not not applicable. manage operation of the pump / 'and limit the temperature of the ,water �r ❑Nat Observable entering the cold water ❑Not Applicable �r piping to <= 1049F. 403.5.4 Drain water heat recovery units Exception: Requirement is [F[31]2 tested in accordance with CSA � ❑ not applicable. Does Not pP 1355 1. Potable water-side �ii'� ",[]Not Observable i; i� i� kpressure loss of drain water heat ��� ��'�� ❑Not Applicable recovery units < 3 psi for PP individual units COMOCted t0 One or two showers. Potable water- ,side pressure loss of drain water i heat recovery units < 2 psi for individual units connected to three or more showers. 403.10.1 'Readily accessible switch on "���i %�; �i�'l, i ,��� ��%�� ' � -]Complies Requirement will be met. [F112]3 heaters for swimming pools or °%'� ,,,%/ �, ��� ��� it El Does Not permanent in-ground spas. %, % ❑Not Observable Switch operation does not change heater thermostat �'�i����`�' � "'� ��� / '❑Not Applicable ;setting. Heater circuit breaker is installed independent of switch 'Gas-fired heaters equipped with ignition pilots that are not ;continuously burning pilots. ii ,��ii�r�iii, ii, 0!/,,,,,�%„ivi,,,, i„pu,,,,,1;• 403.10.2 Timer switches or other /�,�❑Complies Requirement will be met. [FI19]3 automatic reset schedule 0 % ❑Does Not #nwicontrol method are installed on ❑Not Observable heaters and pumps serving pools ,and permanent ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 9 of10 Section ' Plans'verified field'Verified Final Inspection provisions Complies? Comments/Assumptions Ct Re .I Value Value, 403.10,3 Outdoor heated pools and /%i/� / ;����r plies Requirement will be met. [F12013 outdoor permanent spas have a ;;� ';/ �� �� / es Not vapor retardant cover. '�❑Not Observable ❑Not Applicable 404.1 90%or more of permanent plies Requirement will be met. [FI611 fixtures have high efficacy lamps , '�/ LJDoes Not / a❑Not Observable . a❑Not Applicable 4041.1 Fuel gas lighting systems have i ❑Complies Exception: Requirement is [F1 313 no continuous pilot light. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable �40 ,3 Compliance certificate osted, /// /j i��/ �„ "❑Complies Requirement will be met. ❑ [Fi/1 . i i%�rliii ice/ i Does Not Not Observable ❑Not Applicable 3033, Manufacturer manuals for Complies Requirement will be met. [FI�1813 mechanical and water heating �j/ / �f /, ��% �/ ❑Does Not systems have been provided. '�'00�/ /// %� i Y P y /i/�� � � / � � -]Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Pool house 3420 Rocky Point Rd. East Marion, NY Report date: 12/02/24 Data filename: Page 10 of10 Njr ociency Certificate o Above-Grade Wall 19.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling / Roof 47.00 Ductwork (unconditioned spaces): Glass & Door Rating U.-Factor SHGC Window 0.30 0.40 Door 0.30 0.40 Heating & Coolling,Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments East Marion Suffolk County Tax Map No.: 1000-021.00-04.00-008.000 GEM HUNTER PROPERTY 3420 Rocky Point Rd. x DE East Marion,NY PROPOSED A/1 OWTS THE STATE OF NEW YOW TIRE 10 VEPARTHENT OF HEALTH OHAPTER II PART 155TANOAR05 FOR INDIVIDUAL ONS E TER SUP—H0 I ' y A IN IIVIDUAL g SO TEJ4iLFA;fi�•A ;�TQ� A•? ':afl5A'enE SEE Su lk&,-bj Rex1-1.1 SeplI MANUAL ; € 1. 5BEP-5 REOUIRE5116 GPD PER BEDROOH•33D GPD i4 CCSIMIDssz�sucWl OF HEALTH RF`FE£ O O O O 0 C7 C] PROPOSED FUJI"EA LEN S OAPAO O 500GPp>33DGPp (�F GONSTF2UCTION FbaN s ,. s at=9 at a €€s.x :�+ - •T". =s. L€ v RES—EAND � , xs oN FLUB(1)POOL B'DIAHETERX12-DEEPALSO USED FORSD%EXPANSION �! - E O*u or1 xw051 0 POOL - LEA5MX1 HE RO&3.OFA IS 3 T P€RF 4CAWaf i 1'€'.dAL. [[ >�E�O O O C]❑. P50PT•$5%]X1]•600GPD>990 GPO � Rax .�xKx s�wKE _ € , e �o 0 0 0 0 0 � �. TeassL �Eaas ❑I IM®",s- 5 > -.,..x.€. wx6 vT I Imo;s I _ .•rEs x4::sa e'R -.Y §FROKi DATE tE*TF'RC :. I w n0000mEm Twx. _ 0 m a 0— _ xV EL.oe - - - 3 '- . -_��_ n�Frw sous®na � _ • • I cwxPFxE*BAi ox I ¢•: �iec ' , ia•s1 ,e<+a: $ Ixro�x0xslxAu xx0 Poo_ .. . IF vEk �( €xi t• v xxos Pon ka t n�. -. €[( uF owrs � ' I o 1 �x•ekwr.DupE #�' T ile TYP LEACHING POOL `' z o o �L GENERAL I/A Ok4T5 ARRANGEMENT ^ 3 I{I§353,ni9B h°wvinl o c� Nba\4qff N < 3 � � DxTxI=5TE JU 5r 3 I i E d Q \ 1 sh r -} 1 � 00_ m €D tri1 -`a uo s ESL}r:$T3RV0\0 04<3° A N N Fa ,STORY' a O m e 3' - FEDOt7he5 t S H�:°U 5HED _ wiTHilii c'w=a 7 ' \00 €dnNIV o t ' w § =DATE' llI 5550 50'40"W ; i I 1 SCALE: g 4 g]] 51TE PLAN 5HOWING PROPOSED I/A OVgT5 - IISHEET: - i€, I 1= 1 IY`QMIR cRVIYEY 2`� 2<ivY >T5� �l '� East Marion Suffolk County Tax Map No.: 1000-021.00-04.00-008.000 i NE'i DEGia c 0-E EF..aR_-F `20Va'r 1EP:ATEnFEEPEFTOWNT OL FAVE>6`2cA.-W a PNG IN 1'-t u rE- may: - ?•` ._� � Ea.i f�k`2> PhNELUl law -R 4IR.G i«?N P.aE PAh F-. 3 _ _ AIR PUMP GNTRL/AIR PUMP MOUNT HOUSE CONNECTION DETAIL FUJI ONE-LINE WIRING DIAGRAM N.T.S. N.T.S. N.T.S. l FUJI GLEAN GEN 5 NT5 — Coastal Wastewater Sulu-dons LLC Soils Report Sa-z. e z G 3420 Rocky Point Rd .F Z ors-- 0'°-12°°To sail&Fill East Marion,NY 79934 '. o _ ° Tosmof Southold f 2 t 11 FLirtVIB% Countyo[Suffotk Textural Class:Loamy Sand I - -' ��•'<,�- �x 3I €S ���s � I �([li 1� LU Tzural Cta F'neSend Unified Sol t Classificati on:SP Ii. VIEW OF FUJI GLEAN GNTRL PNL s°-ts'. Textural Class:Coarse Sand and Gravel Unified SailSW cv ®� ez"> nl ie ai c 's » _ 501E TEST REPORT is�Z ��_- £.§. - ram- '�W U� VERTICAL VIEW DATE: ]€ n aL � I.I10/10(24 � z =I A � SCALE' x � I GNTRL PNL WIRING SCHEMATIC TOP VIEW sFiEET: N.T.S. r Plan View Dimettisione 1IN-17 ' East Marion Suffolk County Tax Map No.: 1000-021.00-04.00-008.000 ( , a I I ' _ EllI BARN/pool house ATTIC ' R - z LL LV i N ,_ a �6z DARN E'06L HoJSS� ' I€ f [ c STORAGE DATE: s I - I SCALE: FOUNDATION PLAN(CRAWL SPACE ONLY) BARN/pool house AND SHED CONVERSION PLANS i I