Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50703-Z
�? 6pG Town of Southold 8/13/2024 a y� P.O.Box 1179 0 o • ,c' 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45457 Date: 8/13/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1130 Saltaire Way,Mattituck SCTM#: 473889 Sec/Block/Lot: 100.4-30 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/5/2024 pursuant to which Building Permit No. 50703 dated 5/17/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to O'Brien,Timothy&Rebecca of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50703 7/31/2024 PLUMBERS CERTIFICATION DATED th rize S gnature o�sufFot,��v TOWN OF SOUTHOLD BUILDING DEPARTMENT Ca' TOWN CLERK'S OFFICE 2 • SOUTHOLD NY y�ol s ' BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50703 Date: 5/17/2024 Permission is hereby granted to: O'Brien, Timothy 1130 Saltaire Way Mattituck, NY 11952 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1130 Saltaire Way, Mattituck SCTM #473889 Sec/Block/Lot# 100.-1-30 Pursuant to application dated 4/5/2024 and approved by the Building Inspector. To expire on 11/16/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $3.25.00 Building nspector hO�PF SOUT�,QI 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.nv.us Southold,NY 11971-0959 Q�yCOIINT`I,��' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Timothy O'Brien Address: 1130 Saltaire Way city:Mattituck st: NY zip: 11952 Building Permit* 50703 section: 100 Block: 1 Lot: 30 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy Llc.# 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1,ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 8.8kW Roof Mounted PV Solar Energy System w/ (22) CS6R-40OMS-HL Modules, Enphase IQ Combiner w/ (2)22OBreakers & (1)215 For Monitor, On Backfed 40A Breake in Main Notes: Solar Inspector Signature: F Date: July 31, 2024 S.Devlin-Cert Electrical Compliance Form aoF sours Wel -7 � ��� �� I` A t,-e TOWN OF OUTHOLD BUILDING DEPT. IOU 631-765-1802 INSPECTION [ ] FOUNDATION-1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY i NSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR OF SOUlyO6 # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 olo�. JNSPECTION [ ] FOUNDATION 1.ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING ] FRAMING /STRAPPING [ FINAL/Ib [ ] FIREPLACE & CHIMNEY [ ] FIRE:SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION. [ -],'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ✓� v An DATE INSPECTOR 03 Current Rene -des ing Town of Southold July 2, 2024 0 � Subject: Post Installation Approval Letter AVG e,�t Job Name: Timothy Obrien Residence Delp ®�d Project Address: 1130 Saltaire Way, Mattituck, NY 11952 �vio���0 0$ '(0 To Town of Southold: I have reviewed the solar energy system installation in the subject topic on 07/02/2024.The units have been installed on in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Town of Brookhaven, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, SEI/ASCE 7-16, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property, and public welfare. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. 3F NEW yo Sincerely, ���O�RS A, lq��'p� Professional Engineer Current Renewables Engineering F� 106793 info@currentrenewableseng.com �FESSI4NP� Exp:9/30/2025 STAMPED 07/02/2024 1760 Chicago Ave Suite J13, Riverside, CA 92507 info@currentrenewableseng.com (951)405-1733 FIELD INSPECTION REPORT DATE COMMENTS �o FOUNDATION (IST) H ------------------------------------ FOUNDATION 2ND o L Q y � ROUGH FRAMING& PLUMBING l) Q 0 1 r INSULATION PER N.Y. �-k- y STATE ENERGY CODE C IV FINAL ADDITIONAL COMMENTS C aI p awof C o �L °� awl 9ct l3 c r z X x 6� T y O u, z x H x d b H 71'®WN OF SOUTH OLD-BUILDING DEPARTMENT 1 Town Hall Annex 54375 Main road P. ®. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 htcrss:/,v%,,,v-..southoldtownnl•.aov Date Received APPLICATION FOR BUILDING PERMIT�56 I! For Office Use Only PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety.fricompfete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page P)shall he completed, I Date: 'Y-/q 1a- OWNEfR(S)OF PROPERTY: Name:-T EYTCO SCTM#1000- /00 00 _ �1 OU `0 -D�Oct® Project Address: f ] 3 D T�f MA- 1I utic h „ . / Phone#: (D 3 0.. g O `I I Email: � ia- /v�'/ 1 � C 2"S `S e Co on Mailing Address: 11,50 SG--I-7. 06 I y►' , .h 4lA .. 0LI 1 152, CONTACT PERSON.- Name: L_o lr-lr A i n<-,, Pat4f, Mailing Address: -7 47o vLtAd vy-"� Phone#: ��O q I Email: �S -S D� DESIGN PROFESSIONAL INFORMATiOU. Name: Mailing Address: Phone#: Email: CONTRArOR INFO AYION: Name: EAQ men+ 5y)trqq LLt, Mailing Address: L� "�S®VA� Phone#: Q ''� D 'd Email: �i6��� Paz cS E6 ON ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Co tofProject: then I Inb+a,O �b hXr PV $ a tl� Will the lot be re-graded? ❑Ves;.No Will excess fill be removed from premises? ❑Ves)AC) I i 1 PROPERTY INFORMATION Existing use of property: Intended use of property: QRLS Zone or us (strict in which premises is situated: Are there any covenants and restrictions with respect to S this property? ❑Yesr o IF YES, PROVIDE A COPY. �-Fecllox After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by apf the Town Code. APPLICATION 15 HEREBY(MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section Z10.45 of the New York State Penal Law. Application Submitted By(print name).Lorraine ®i Penta ®Authorised Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) LOUIS J ROMEO SS: Notary Public,State of New York No.01 R06314813 COUNTY OF Suffolk ) Qualified in Suffolk County Commission Expires N,p vember 17,20 Lorraine ®(Penta being duly sworn, deposes and says that(s)heis the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized-to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of At -c 20_t otary Vublic LOUIS J ROMEO Notary Public,State of NewYork No.01 R06314813 PROPERTY OWNER AUTHORIZATION Qualified it Suffolk County Where the a is not the owner Commission Expires November 17,20Zb� applicant Pp � ) bIlrl c'h residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. wner's Signature Xte LOUIS J ROMEO Notary Public,State of New York No.01 R06314813 Print Ow 's Name Qualified in Suffolk County Commission Expires November 17,20 x4 2 . SuffOA� BUILDING DEPARTMENT- Electrical Inspector Gym TOWN OF SOUTHOLD w = Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(@-southoldtownnV_gov-.seand(&_southoldtownny gov APPLICATION FOR ELECTRICAL INSPECTION [Electrician's LECTRICIAN INFORMATION (Au information Required) Date: q=9C Name: �1l1 CA4 Er)? r- ICI, t� Name:DF� )' g�,� License No.: q - 1\4 F Elec. email: Per-rn s+5 S C,aS Elec. Phone No: -)ojc13 [9I request an email copy of Certificate of Compliance Elec. Address.: ® �o aV.f., JOB SITE INFORMATION (All Information Required) Name: )'mo+1, 0 2)V-It.V) Address: IQ 3a -I�- 66 ry, W XAIA I q S Cross Street: -13 Q ULn 6C-vl\f_0 Phone No.: (02) 7 O Lf J Bldg.Permit#: email: 9?,M Tax Map District: 1000 Section: 100 Block: O 1 Lot: 63 0 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): S&t� P/ sdj�n Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES® NO [—]Rough In Final Do you need a Temp Certificate?: ❑ YES® NO Issued On Temps Information. (All information required) Service SizeF11 PhF—]3 Ph Size: A # Meters Old (Meter# ®New Service®Fire Reconnect❑Flood Reconnect®Service Reconnect®Underground®Overhead # Underground Laterals 1 n2 D H Frame M Pole Work done on Service? n Y FIN Additional Information: rls-�r�1,� f ` 1,� fl,� m,��Ln}�u( cS�l ter°P✓ S -t,n1 PAYMENT DUE WITH APPLICATION a' workers' CERTIFICATE OF INSURANCE COVERAGE STATE COi11F7enS8t10R Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie .Ia.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work Location of Insured onl re ulred.ifeaver a is or Social Security Number ! Y 4 ag specillcally limited to certain locations in New York State,i a.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being listed as the Certificate Bolder) ShelterPoint Life hisurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"I&' SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01101/2023 tQ 12/31/2024 4. Policy provides the following benefits: ® A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employees employees eligible under the NYS Disability and Paid Family Leave Benefits Law. C] B.Only the fallowing class or classes of employers ernpkryees: Under penalty of perjury,1 certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that-the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage.as described above. Date Signed 7/10/2023 By 46w, &f ftnature of insurance camels authorized representative or NYS ucensed Insurance Agent ofttz insurance carrier) Telephone Number 516-829-8100 Name and Title Richard Waite, Chief Execulive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail It directly to the certificate folder. If Box 4B,4C or 5B is dmked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emalled to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. rAT 2.To Ile completed by the NYS Workers'Compensation Board(only d Box 46,4t or 5e have been f hecked)State of New York Workers' Compensation Board ccording to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.f.insurance brokers are PLOT authorized to issue this form. De-120.1 (12_21) ����� ►11�1�1�1111�116�I1ii11�lllll��� A R� CERTIFICATE OF LIABILITY INSURANCE DaTEleeM7`1roD1rm THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER ROBERT S. FEDE INSURANCE AGENCY NAME: PHONE FAX 23 GREEN STREET,SUITE 102No.Exl AXc No): E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE WSU AFFORDING COVERAGE NAIL a INSURER A:ATLANTIC CASUALTY INS.CO. 524210 L747O nt Energy LLC INSURER LEMENT ENERGY SYSTEMS ,NsuRERc: GENERAL S SOUND AVENUEINSURM D" ITUCK,NY 11952 INURERE: INSURER F COVERAGES CERTIFICATE NUMSEi3: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR ITYPE OF INSURANCE POLICY NUMBER POLICY lou EFF tumn"Crm EXP°0 LIMITS IX I COMMERCIAL GENERAL LIABILITY L145DO36873 A X X 7/14/2023 7/14/2024 EACH OCCURRENCE s 3,000,000 CLAIMS-MADE OCCUR LIAN14GE TO PREMISES EaocewTenea $ 100,000 Y44389203B MED EXP{An are permit) $ 5j00D rG.EINIL Contractual Lia 7/1912022 7/19/2024 PERSONAL a ADV INJURY $ 30000M GREGATE LIMITAPPLIES PER GENERAL AGGREGATE i 3,000,000PRO FI- CY X JECT LOCPRODUCTS-GOL�lOPAGG $ER: s AUTOfA0RLEL1ABILITY CErNEDSWGLELIMff $ ANY AUTO BODILY MiJURY{Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per ardent) $ HIRED NON-OWNED DAMAGE PROPERTY AUTOS ONLY AUTOS ONLY $ P, Mar UMBRELLALIiB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAMAS MADE AGGREGATE g DED RETENTICN$ $ WORKERS COMPENSATION 124494445 PER oTH AND EMPLOYERS'LIABILITY YIN 7/13I2O23 7/13/2024 AT ER ANY PRCPRIETORIPARTNERIEXECUTNE B NFRC�dE� MBE EXCLUDED? NIA E.L EACH ACCIDENT $ 1 000 000 If M.descrbe under EL DISEASE-EA EMPLOYE $ tNY RIPTION OF OPERATIONS below EL DISEASE-POLICY L1MR $ State DBL D13L557527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS/LOCATION I VEHICLES(ACORD 101,AddMenal Renu ti Schedule,any be atlacmd H ewee space In Mcpdre* CERTIFICATE HOLDER IS ADDITIONAL INSURED Certlificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHCR¢ED REPRESENTATIVE RQUe tS- Fede, O 1988-2015 ACORD CORPORATION. All rights reserved. ernon 94 11JAaa/n111 NYSIF New York State Insurance Fund PO Box 6W99,Albany,NY 122C6 I nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) n n n n n n 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 VIA HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC N OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS TOWN 7470 SOUND AVENUE 54375 AD MAIN IN ROAD 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 369075 07/13/2023 TO 07113/2024 711IM23 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444.5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLiCYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT NTTPS.IIWWW.NYSIF.COMICERTICERTVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY_ THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION,AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU CE FUND �/ DIRECTOR,INSURANCE FUND UNDERWRITING D y_ APR 0 ED AS NOTED �J DATE-5 B.P. F BY: NOTIFY BUILDING DEPARTMENT AT 631-765-1602 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLDTO A SOUTHOLD T PLANNING BOARD SOUTHOLD OWN TRUSTEES N,YS.D S LD HPC OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED ENPASE 108 and + Microinverters Ciur newest 108 k5crobiver2ers aye i<ndUeuy'&firs rrricgogriEt fol alg,.softwars- � ight�,neig a;rre ccrrrpa€t with defined rnicroinverterswiihsplit-phase power conversion capabirrey'tocoalvw;C' Winer 10 AC'Pcwsv 9fficien3Ey.he brain or niles�miean€fu€#o�-�S�sedrrsioxoirlve�es is our proprietary appiica ten-specific in3agrated'circuf{A51CY whichierlabies t he *rer iseF�;e al lr: isn microimrerter to operate in grid-tieddor af;_c�e�d'modes..This•chip'rsbuiitin,QuVa�-ced C b uco rear 55nrrrtechnotogywhipiligh speed digital logic-Mdhassuper=fasaresponse-irrie-- Ws€aiiavent r'siM to,changing Go sandgai t•ovearts;a viffi irlgcorls�zin s on bait sizing;for ho =-' e'Cab ig energy systems. ?'ipc areftWay. �Fr;• -- _"� �'�dE���FfyrF��'�t�iw�1£Tr�7Q• -- �:m;• E�iii3ii3•E4rE3V1Fi•:y ��� ' - � t719or�ti;asgol�;:¢r3ii�n ctsrnufalive _ ftr rs eF testing, Part oftheEnphase Energy System,IQB'Saries• IQ8'SeriesNbroinvertersredeffnereliabiYsty eTMfiDSW&, ,itaCicrcimrerters integrate Mth the Enphase 10 B'attery, standardswith more than,onemllfwn,cumulative Enphase IQ Gateway,and the Enphase App monitoring hours cf power-on testing, riii2 fi.^P' EeFZ`i3S$�1i fit- enabling an industry- and analysis software. leading limited warranty of up to-25 years. fr't�'rrrh3fiCr�BS adv-Wcedglr€dst,pporr" Remote au'tc mado updates for the rates$gild requkements Connect PV modules quickly and easily to I08 Series I08 Series Winroinverters are UL Listed as Micrcinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with P �olmflgtSlaDfetc StSSlpor3���� cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grids prQiz� manufacturer's instructions. Meets Chi RuEe 21'(UL 1741'-S,R) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other 'Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. I08 and IQBPius supports split phase,240V IQ83P-OS-0002-01-EMI-US-2022-03-17 installations only. I08 and IQ8+ Mioroinverters 1foci, ,: .1 ,. Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-ceil,66-cell/132 half-cell and 72-cell/144 P Y half-cell MPPT voltage range v 277 37 29-45 Operating range v 25-48 25-58 Min/max start voltage V 30/'48 30/58 Max input DC voltage V 50 60 Max DC current'[module Isc] A 15 Overvoltage class DC port II DC port backfeed current MA 0 PV array configuration lxl Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT ITATA1 Peak output power VA 245 ( 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range v 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over - 2 3 cycles Anns Max units per-20-A(L-L)branch circuit° 16 13 Total harmonic distortion <5% Overvoltage class AC part III AC portbackfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -4006 tolii6 C(=40c to i14(IcF) Relative humidity range 4%to 100%(condensing) DC Connector type. MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(12") Weight ,1i08 kg(2.`38Ibs) Cooling Natural convection-no fans Approved for wet Iodations Pollution degree PD3 Enclosure Class II double-insulated;corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.1071=01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(41,Limits may vary.Refer to local requirements to define the number of micrcirverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2022-03-17 XR Rails XR10 Rail r XR100 Rail XR, 1000 Rail Bonded Splices - ova _ A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability s 8'spanning capability . 12'spanning capability - Self-drilling screws • Moderate load capability \ I Heavy load capability - Extreme load capability - Varying versions for rails • Clear and black finish Clear and black finish - Clear anodized finish - Forms secure bonding Clamps & Grounding (B UFOs Stopper sleeves Grow ndOng Lugs M15croinverter Kits s.SA liO 1 14 J1 M --NEW Universal Fastening Objects Snap onto the UFO to turn ys to Mount Mis or POs to XR bond modules to rails. into a bonded end clamp. equipment ground.- Rails. * Fully assembled & lubed - Bonds modules to rails - Low profile - Bonds devices-to rails * Single, universal size - Sized to match modules - Single tool installation - Kit comes assembled * Clear and black finish - Clear and black finish - Mounts in any direction - Listed to UL 2703 Attachments FlashFvoV Conduit Mount Bonding Hardware A, 21 sum 7q N ........... ....... Flash and mount XR Rails Flas d mount conduit, esign for rapid rail Bond and attach XR Rails with superior waterproofing. ut, or junction boxes. attachment. to roof attachments. • Twist-on Cap ease--' all - Twist-on Cap eases install - Secure rail connections - T&Square Bolt options • Wind-driven rain tested - blind-driven rain tested - Slot for vertical adjusting . Nut uses 7/16"socket • Mill and black finish - Secures 3/4"or 1"conduit - Clear and black finish - Assembled and lubricated Resources 7- Design Assistant NABCEP Certified Training Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems.Go to Iron Ridge.c orn/design 1%eF Go to IronRidge corn'training �.. , . [RONRIDGE Flush Mount System t y --_ M . - '�'R-D'£'^+�: = - - '.e-"1s3� „gn•;&,r ��cc,+£;Y_ _-.�>:-�_.--3'--.�'- Y�='..:T=�-:se trm, fy'_ _ -•?-;,t _�=i{s:.,l.._'_: - -_ _ "_-- --tia..-...._._._ .�-•,.> ?:;� ,.;*r{a,�.,�-�,"' - - -__ - -_Are'� _----_`��'~`_``�'' �:.a:.�r +�" Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tasted PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire [Datong � Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. to w, rx �r CanadianSo'lar Preliminary Technical � ,,..�.' .� - Information Sheet H i Ku6 (All-Black) ALL BLACK MONO PERC 380W - 405W CS6R-380 1 385 1 390 1 395 1 400 1 405MS-H L MORE POWER oa� IndusryLeading Product Warranty on Materials and Workmanship* Module power up to 405 W 405 W Module efficiency up to 20.7% 25 - Linear Power Performance Warranty* Years) Lower LCOE&system cost V year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% *Subject to the terms and conditions contained in the applicable Canadian Solar limited Warranty Statement.Also this 25-year limited product warranty Is available only for prod- Comprehensive LID/LeTID mitigation ucts Installed and operating on residential rooftops in certain regions. technology,up to 50%lower degradation ............................................................................................................................... MANAGEMENT SYSTEM CERTIFICATES* ISO 90012015/Quality management system = Better shading tolerance ISO 14001:2015/Standards for environmental management system C�J ISO 45001:2018/International standards for occupational health&safety PRODUCT CERTIFICATES* MORE RELIABLE IEC 61215/IEC 61730/CE/INMETRO UL 61730/IEC 61701/IEC 62716 Take-e-way Minimizes micro-crack impacts oVE sAU9� E 4—M �! *The specific certificates applicable to different module types and markets will vary, Heavy snow load u to 7000 P and therefore not all of the certifications listed herein will simultaneously apply to the ** p a products you order or use.Please contact your local Canadian Solar sales representative i� wind load up to 5000 Pa* to confirm the specific certificates available for your Product and applicable in the regions In which the products will be used. .........................................................................I....................................................... CSI SOLAR(USA)CO.,LTD.is committed to providing high quality solar photovoltaic modules,solar energy and battery storage solutions to customers.The company was recognized as the No.1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight *Pending testing confirmation.For detailed information, Survey.Over the past 20 years,it has successfully delivered over 67 GW please refer to the installation Manual. of premium-quality solar modules across the world. .............................................................-----....................................------------------..................................................................................-..............---------................................ CSI SOLAR(USA)CO.,LTD. 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597,USA I www.csisolar.com/na I service.ca@csisolar.com ENGINEERING DRAWING(mm) CS611400MS/I-V CURVES A A Rear View Frame Cross Section A-A 14 14 - 13 -- 13 A-A 1z u - 6•ms - GrcundingHole I 5 to 9 - 9 -_ 8.14x9 Mounting Hole 7 1 C7 6 6 5 S 4 4 p o 3 3 0 2 2 Mounting Hole u u I 5 10 15 20 25 30 35 40 45 So 55 60 5 10 15 20 25 30 35 40 45 50 SS 60 ■ 7000 W/m' SC ■ ■ goo W/m� 25•C ■ ❑ ■ 600 W/m' 45•C ■ 400 W1W 65•C ■ "Ila ■ 200 Win, ELECTRICAL DATA I STC* MECHANICAL DATA CS6R 38OMS 385MS 390MS 395MS 40OMS 40SMS Specification Data Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp)30.0 V 30.2 V 30A V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X 6)] Opt.Operating Current(Imp)12.69 A 12.77 A 12.94 A 12.91 A 12.99 A 13.07 A 1722 x 1134 x 35 mm Open Circuit Voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V Dimensions (67.8 x 44.6 x 1.38in) Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 213 kg(47.0 Ibs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti- Operating Temperature -40"C-+85°C reflective coating Max.System Voltage 1500V(1EC/UQ or 1000V(IEC/UL) Frame Anodized aluminium alloy, J-Box IP68,3 bypass diodes Module Fire Performance TYPE 1(UL 617301500V)or TYPE 2(UL 61730 Cable 4 rnm2(IEC),12 AWG(UL) 1000V)or CLASS C(IEC 61730) Max.Series Fuse Rating 25 A Connector T6 or MC4 series Application Classification Class A Cable Length 1550 mm(61.0 in)(*)/ Power Tolerance 0-+10 W (Including Connector) 850 mm(33.5 in)(-) *Under Standard Test Conditions(STC)of Irradiance of 1000 w/m',spectrum AM 1.5 and cell tempe- Per Pallet 30 pieces ratureof25°c Per Container(40'HQ) 780 pieces *For derailed Information,please contact your local Canadian Solar sates and technical representatives. ELECTRICAL DATA I NMOT* CS6R 380MS 385MS 39OMS 395MS 40OMS 40SMS TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data Opt.Operating Voltage(Vmp)28.1 V 28.3 V 28A V 28.6 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0.34%/eC Opt.Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Voc) -0.26%/eC Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/°C Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A *Under Nominal Module Operating Temperature(NMOT),irradlanceof800 W/m;spectrum AM 1.5, Nominal Module Operating Temperature 42 t 3*C ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION .................................................................................................................. +The specifications and key features contained In this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.CSI Solar Co.,Ltd.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. ................................................................................................................... .................................................................................................................................................................................................................................................................... CSI SOLAR(USA)CO.,LTD. June 2022 1 All rights reserved I PV Module Product Datasheet v1.5C25_F23J2_NA ENGINEERING DRAWING(mm) CS6R-400IMS I-V CURVES Rear Vievi Frame Cross A A A -A 14 13 A-A 3 .......... ... 35 10 . ....... .... o -.1 4.�9 _. 7 6 - ------- L 4 4 3 :. 2 Mounting,Hole ------ ------ v 5 10 15 20 2,30 35 40 45 50 55 60 5 10 15 20 25 30 35 40 45 50 55 60 7wow".- goo wl 5'C x 600 Wim- 25ac a 400'& 451C 1 200'N1 ELECTRICAL DATA STC* CS6R MECHANICAL DATA 380-MS 385MS 390MS 395MS 400MS 405MS Specification Data Nominal Max.Power(Pmax) 380W 385W 390W 395W 400W 405W Cell Type Operating opt. -.Mono-crystalline�ltage.(Vrfj_R�30.CV 30,2V 30.4V 30.6V' 3O.8V 31.0V Cell Arrangement n X(9 X 6) -.91 A 12.99 A 13.07 A 1722 x 1134 x 3.5 Trim Opt.Operating Current(Imp)12.69 A 12.77 A 12.84 A 12 1 Open Circuit Voltage(Voc) Dimensions 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V Short Circuit Current(Isc) 13-55 A 13.63 A 13.70 A 13..77 A 13.8 - - (6-7-8 x 44.6 x 1.38in) 5-A 13-93 A Weight 21-3 kg(47.0 lbs Module Efficiency 19.5% 193% 20.0% 20.24'a 20.5% 20.7-- Operating Temperature % Front Cover 3.2 mm tempered glass with anti- -40'C-+85*C reflective coating Max.System Voltage 1500V(IECIUL)or 1 000V(lEC/UQ Frame Anodized aluminium alloy, ]-Box IP68,3 bypass diodes.I Module Fire Performance TYPE 1 (LIL 61730 1 500V)or TYPE 2(UL 61730 1000'6)Or CLASS C(IEC 61730) cable '4 mm'(IEq,12 AWG(LJQ Max-Series Fuse Rating 25 A - - Connector T6 or MC4 series Application Classification Class A Cable Length 1550 mm(61.0 in) Power Tolerance (Including Connector) 010W 850 mm(33.5 in) *under 5randarc!Test conditions(STC)of irradiance of 11)(70 VV Per Pallet racure of 251c. /M',spectrum AAJ 15 and cell rempe- 30 pieces Per Container(40'HQ) 780 pieces For derailed please' ----contact your local Canadian solar sales--and technical representatives. ELECTRICAL DATA I NMOT* CS6R . 380'MS 385MS 39OMS 395MS 4'OOMS 405M5 TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Opt.Operating Voltage(Vmp)28. Data IV 28.3 V 28.4 V.28.6 V 28.8 V 29.0 V - Opt.Operating Current(Imp)10.12 A 10.19 A 10,26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Pmax) 0.34% "C Open Circuit Voltage(Voc) 33,9 V 34. Temperature Coefficient(Voc) -0.26%/,- I V 34.2 V 34.4 V 34.6 V 34.7 V C Short Circuit Current(1sc) 10.91 A 10.98 A 11.05 A I I.11 A 17.17 4 11.23 A Temperature Coefficient(Isc) 0.05%/*C *Under Nominal Module Operating Temperature(NMOT),irradiance of 800 W/m<spectrum Am I.S. Nominal Module Operating Temperature 42 3'C ambient temperature 20-C.wind speed 1 m/s. PARTNER SECTION . ..... ....... • The specifications and key features contained in this clatasheer may deviate slightly from our act products due to the on-going innovation and product enhancement-CS1 solar Co.,Ltd.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that Pv mocuies Should be handled ano installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our Pv modules. CSI SOLAR(USA)CO., LTD. June 2022 1 All rights reserved PV Module Product Datasheet v1.5C25_F23j2_NA of 2 Current 04/03/2024 Renewables ELEMENT ENERGY LLC. to Engineering Subject: Structural Certification for Installation of Residential Solar Job: Timothy Obrien Residence Project Address: 1130 Saltaire Way, Mattituck, NY, 11952 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of ELEMENT ENERGY LLC.. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural_Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 127.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 Of NEwY A. Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com y CFO 106793 =V A E Np� Signed on:04/03/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com of 2 Summaries: Check 1: Shingle roofing supported by 2x6 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 20 degrees and has a max beam span of 16.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com CODE INFORMATION ROOF MOUNT SOLAR PERMIT PACKAGE FFI_ FTHE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC TIMOTHY 0 B R I E N POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2020 BUILDING CODE OF NEW YORK STATE 8.800 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 RESIDENTIAL CODE OF NEW YORK STATE 2020 EXISTING BUILDING CODE OF NEW YORK STATE 2020 FIRE CODE OF NEW YORK STATE 1130 SA LTA I R E WAY, M ATT I T U C K, NY 11952 2020 MECHANICAL CODE OF NEW YORK STATE 2020 PLUMBING CODE OF NEW YORK STATE 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE 2017 NATIONAL ELECTRICAL CODE BUILDINGINFORMATION THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 1 STORY HOUSE SINGLE FAMILY RESIDENCE ACCOUNT NO : 9887503305 EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U RENEWABLES ENGINEERING INC METER N0: 98303037 AHJ : TOWN OF SOUTHOLD ROOF:COMP SHINGLE APN:1000100000100030000 PV SYSTEM SUMMARY: WIND SPEED 127 Current SYSTEM SIZE(DC) STC:400 x 22=8.800KW DC SNOW LOAD 25 RenewaWeF P EXPOSURE CATEGORY D Engineering TC:376.70 x 22=8.2874KW DC of NEWYO L SYSTEM SIZE(AC) 6.380KW AC @ 240V �P� A. CURRENT RENEWABLES MODULES (22)CANADIAN SOLAR:CS6R-400MS-HL oeER �4 'Q� ENGINEERING INC. 1760 CHICAGO AVE SUITE PHONE 95SID �7 05-1733 WWW.CRENG.CO MICRO-INVERTERS ENPHASE: IQ8PLUS-72-2-US r W AERIAL VIEW VICINITY VIEW CONTRACTORINFO MICRO-INVERTERS QTY 22 2S a TILT 20' F� 106793 AZIMUTH 60' A��FES54 P� M ROOF COMP SHINGLE Exp:9/30/2025 8 RAFTER/TRUSS SIZE 2"X6"RAFTER @ 16"O.C. �����" ATTACHMENT TYPE IRONRIDGE HALO ULTRAGRIP WITH IRONRIDGE Stamped 04/04/2024 XR-100 RAIL ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTRUCK, MAIN SERVICE PANEL EXISTING 200AMPS MSP WITH 200AMPS MAIN NEWYORK,11952 PH:(631)779 7993 INTERCONNECTION BREAKER ON TOP FED serv_ Lice -@M sys.co9 OCPD RATING PV BREAKER ' } (MASTER ELECTRICIAN) 40 AMPS Licence-HI-67461 UTILITY LONG ISLAND POWER AUTHORITY (SUFFOLK HOME IMPROVEMENT) Solar Individual GENERAL NOTES: f Permit Package 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED SHEET INDEX TIMOTHY OBRIEN 4, ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH U1_2703,UL1741 AND UL1703 PV_1.0 COVER PAGE 8.800KW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7, THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8 THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9, IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PV-3.0 STRUCTURAL 1130 ,NYY 11952 WAY, MATTITUCK UCK 10 EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" PV-4.0 ELECTRICAL KID Rev I Description Date 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS PV-5.0 ELECTRICAL SLID A INITIAL DESIGN 4i412024 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" 13, PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM 14 PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. PV-7.0 ELECTRICAL PHOTOS OPPORTUNITY TIMOTHY OBRIEN 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PV-8.0 SIGNAGE PROJECT# 9ooz 16, INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 17 ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.1 PLACARD DATE DRAWN 4i4i2024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY E R 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8"ABOVE ROOF SURFACE. PV-9.0 M ICROI NVERTER CHART SHEET# PV-1.0 19 IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE PV-10.0 SAFETY PLAN ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0 SAFETY PLAN COVER PAGE 20, MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: PV-12.O+ SPEC. SHEETS F 24.6.1 PATHWAYS: r�'1 A 'D T LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON WIND SPEED 127 EV NPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON SNOW LOAD 25 ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR EXPOSURE CATEGORY D UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM �Q j q O MSP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE (7 eER �9 �� SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING O n � THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE * * a COMBINER OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS r ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR I a MODULE MECHANICAL EQUIPMENT. R324.6.2 SETBACK AT RIDGE: ROOF OBSTRUCTION �`r�` 106793 t� ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 Q PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN p��FESSIONP� AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A ROOF ACCESS POINT THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. ROOF ACCESS POINT COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 (N)COMBINER Exp:9/30/2025 REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A (E) UTILITY METER Stamped 04/04/2024 WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. PROPERTY LINE RENEWABLES ENGINEERING INC (E)MAIN SERVICE PANEL R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED SHED THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 200' I Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE _____ PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. - ---- -------------- - --- ---- ----------------------------------______ e�n e v'+ A -PATHWAY ON STREET ' ' Engineering OR DRIVEWAY SIDE OF ROOF I B -FIRE ACCESS POINT ' I ENGINEER NG INC. NT EWABLES EEi! I 60 CCAGO AVE SUITE 32'-9" J71RIVERSIDEERSE CA 92507 36"ACCESS PATHWAYS i I PHONE(951)d05-1733 � WWW.CRENG.CO 18"ACCESS PATHWAYS I I CONTRACTOR INFO Q NOTES: ' 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND LU ' DRIVEWAY MEASUREMENTS. s I 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS Q I CZSYS INCORPORATED INTO THE 2017 NEC AND UL STANDARD 1741. i 3. EXISTING ROOF VENT SHOULD NOT BE I I ELEMENT ENERGY LLC. COVERED. 7470 SOUND AVENUE,MATTITUCK, iNEW YORK,11952 NOTE: I PH:(631)779 7993 i services@e2sys.com NO FENCES OR GATES SURROUND THE PROPERTY T_ i I Q Licence-ME-52689 o 601-111 i (MASTER ELECTRICIAN) I —' Licence-HI-67461 (SU 109' I FFOLK HOME IMPROVEMENT) Solar Individual I Permit Package II TIMOTHY OBRIEN -- ---� 8.800KW Grid Tied ---------------------------- -- - ----- ---------------------------------- ------ Photovoltaic System 200' 1130 SALTAIRE WAY, MATTITUCK,NY 11952 ROOF LINE PROPERTY LINE Rev Description Date ROOF ACCESS POINT A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 SITE PLAN DRAWN BY ER 1 SHEET# PV-2.0 TITLE SCALE: 3/64" = 1'-0" SITE PLAN ARRAY AREA LEGEND EAVE TO ROOF ROOF TOTAL #OF RIDGE ARRAY AREA AREA AREA ROOF ROOF TYPE AZIMUTH AREA MODULES DIMENSION (Sq.Ft.) (Sq.Ft.) COVERED BY COVERED BY (Ft.) ARRAY %) ARRAY(%) UM UTILITY METER #1 COMP SHINGLE 60 22 15.7 462.44 1863 24.82 24.82 MSP MAIN SERVICE PANEL STRUCTURAL NOTES : (N)COMBINER c❑ COMBINER 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE (E)UTILITY METER MODULE PROPOSED PV INSTALLATION ONLY. 2. THESE PLANS ARE NOT STAMPED FOR WATER ROOF OBSTRUCTIONS LEAKAGE. THESE DRAWINGS ARE SUBJECT TO 3. PV MODULES, RACKING,AND ATTACHMENT C UM COPYRIGHT PROTECTION BY US LAW. COMPONENTS MUST FOLLOW MANUFACTURER REPRODUCTION IN ANY FORM IS MSP (E)MAIN SERVICE PANEL EXPRESSLY FORBIDDEN WITHOUT PRIOR GUIDELINES AND REQUIREMENTS. WRITTEN APPROVAL FROM CURRENT 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL - RENEWABLES ENGINEERING INC CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. ��,� NEW y 5. PRIOR TO THE COMMENCEMENT OF WORK, THE SOLAR A�P O INSTALLER SHALL VERIFY THE ROOF FRAMING Current��0��� (q���� wableS INFORMATION BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE r fi Engineering VERIFICATION AND THE FOLLOWING: 2x6 RAFTERS @ 16" n ,ICURRE W OC SPACING WITH A MAX UNSUPPORTED SPAN EQUAL TO ti o = ENGINEERING INC. LES OR LESS THAN 16 FT. �O t ENGINEERING INC. 106793 `� 1760 CHICAGO AVE SUITE trESS1Y PHONE RIVERSIDE-1 92507 'r Y` PHONE:(957)d05-1733 WWW.CRENG.CO ROOF#1 Exp:9/30/2025 CONTRACTOR INFO Stamped 04/04/2024 ,a N M EZSYS9 Stamped 04/04/20 ELEMENT ENERGY LLC. Q 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 L I.I services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) QLicence-HI-67461 L_ (SUFFOLK HOME IMPROVEMENT) J Solar Individual < 1'-6" Permit Package TIMOTHY OBRIEN 8.800KW Grid Tied (N)#22 CANADIAN SOLAR: Photovoltaic System CS6R-400MS-HL 1130 SALTAIRE WAY, MATTITUCK,NY 11952 [DATE Desuiption Date INITIAL DESIGN 4/4/2024 ORTUNITY TIMOTHY OBRIEN JECT# 9002 3' DRAWN 4/4/2024 WN BY E.R OOFET# PV-21 TITLE SCALE: 1 18" = 1 -0" ROOF PLAN ROOF ROOF ROOFING FRAMING FRAMING OC PENETRATION MAX NO TILT TYPE ATTACHMENT TYPE TYPE SIZE SPACING PATTERN PENETRATION MAX SPACING OVERHANG ROOF 1 20 COMP SHINGLE IRONRIDGE HALO ULTRAGRIP RAFTER 2"X6" 16" FULLY STAGGERED 48" 24" THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC Current Renewabtes Engineering CANADIAN SOLAR: CS6R-400MS-HL CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE IRONRIDGE XR-100 RAIL TABLE PENETRATION PH E (951)IDE-1733CA 7 PHONE:(9511306-1733 GUIDE FOR INSTALL WWWCRENG CO CONTRACTORINFO TWO OR MORE ROWS OF PANELS 4• (E)COMP SHINGLE r••— 2.5"MIN.EMBED. IRONRIDGE HALO ULTRAGRIP I I I I I I I I I I I I I I I I I I I I E2SYSg I I I I I I I I I I I I I I I I I I I I ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 2- #14 X 3"X RD STRUCTURAL WOOD SCREWS TO NEW PORK,11952 P EXISTING RAFTER I I I I I I I I I I I I I I I I I I I I services@e2sys.comH:(631)779 7993 I I I I I I I I I I I I I I I I I I I I Licence-ELECTRICIAN) (E) 2"X6" RAFTER@ 16"O.C. tff- (MASTER ELECTRICIAN) 67461 ENLARGED VIEW c� W f, Licence-HI PROV OF NE (SUFFOLK HOME IMPROVEMENT) `Q Rj A. �n STACKED STAGGERED FULLY STAGGERED (qo '/� Solar Individual IRONRIDGE XR-100 RAIL ONE ROW OF PANELS* Permit Package r IRONRIDGE HALO ULTRAGRIP 1 W TIMOTHY OBRIEN �.�.�. CANADIAN SOLAR: CS6R-400MS-HL �J' 106793 �� 8.800KW Grid Tied F '�O I I I I I I I I I I I I I Photovoltaic System SEE ENLARGED VIEW FESSIONP�� I I I I I I I I I I I I I 1130 SALTAIRE WAY, Exp:9/30/2025 MATTITUCK,NY 11952 Stamped 04/04/2024 FULLY STAGGERED STACKED/STAGGERED Rev Desalption I Date (E)2"X6" RAFTER @ 16"O.C. A INITIAL DESIGN 1 4/4/2024 OPPORTUNITY I TIMOTHYOBRIEN ATTACHMENT DETAILS (E)COMP SHINGLE PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWNBY ER SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING ' MAX. CONTINUOUS OUTPUT 1.21A @ 240V OF NE��E w yO MA ,p 26.62 X 1.25 = 33.28AMPS 40A BREAKER-OK ACCOUNT NO : 9887503305 D LU METER NO: 98303037 yN 099128 (E)UTILITY METER CTRIC, (E)200A RATED — SS,�NP� (N)ENPHASE MAIN SERVICE PANEL COMBINER BOX MODEL 1PH.120/240V60HZ STAMPED 04/04/2024 NO#X2-IQ-AMI-240-4 (E)200A/2P MAIN BREAKER (TOP FED) CELL WIRE LESS THESE DRAWINGS ARE SUBJECT TO MODEM COMMS COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR IQ GATEWAY WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (11)IQ8PLUS-72-2-US — 2-Q Cable(AWG#12,SKU:Q-12-RAW-300,THHN) /jam MICROINVERTERS 1-#B AWG,BARE COPPER GROUND (N)15A'/1 77 •� Current 116CANADIAN NT �uer-lh�cS SOLAR:CS6R-40OMS-HL 0-��n ———————7 (N)20A/I� • Engineering (11)IQ8PLUS-72-2-US /�~ (N)40A/2P PV MICROINVERTERS (N)20�� j BREAKER • CURRENT RENEWABLES j /~ TO UTILITY ENGINEERING INC. OVERHEAD 1760 CHICAGO AVE SUITE BRANCH-2 J-13 RIVERSIDECA92507 11 CANADIAN -- �j L---------------- ------------- --- FEED PHONE (951)-405-1733 N --- ------ ----------- - SOLAR:CS6R-400MS-HL 9 I— z----- wwwcRENGco I CONTRACTORINFO 3-#8 AWG,THWN-2 `------------- 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC CONDUIT (E)GROUNDING ELECTRODE CONDUCTOR #6 BARE COPPER C 2 SYS9. ELEMENT ENERGY LLC. SOLLARAR MODULE MANUFACTURER CAN 7470 SOUND AVENUE,MATTITUCK, C56R-40OM5- NEW YORK,11952 MODULE MODEL HL PH:(631)779 7993 services@e2sys.com MODULE(W) 400 Licence-ME-52689 MODULE PTC(W) 376.70 (MASTER ELECTRICIAN) MODULE Isc(A) 13.85 NOTE: Licence-HI-67461 MODULE Voc(V) 36.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS (SUFFOLK HOME IMPROVEMENT) MODULE Imp(A) 12.99 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package MODULE Vmp(V) 30.80 PROPER JUNCTION BOX AT EACH END PER 690.31A TIMOTHY OBRIEN WIRE SCHEDULE STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 8.800KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT Photovoltaic System # EQUIPMENT WIRE LOCATION QTY. WIRE AMPACITY RATING (°C) FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 1130 SALTAIRE WAY, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date A INITIAL DESIGN 4/4/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.31 0.96 1 28.80 16.64 3 AC COMBINER TO POI EXTERIOR WALL 3 8 55 90° 26.62 0.96 1 52.80 33.28 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV4.0 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING ' MAX. CONTINUOUS OUTPUT 1.21A @ 240V OF NE�P,<<G �MANW yo 26.62 X 1.25 = 33.28AMPS 40A BREAKER-OK ACCOUNT NO : 9887503305 D w m oss128 W METER NO: 98303037 tiN _ (E)UTILITY METER CTRIGP� (E)200A RATED — SS1O�1P� (N)ENPHASE MAIN SERVICE PANEL COMBINER BOX MODEL 1PH,120/240V 60HZ STAMPED 04/04/2024 NO#X2-IQ-AMI-240-4 (E)200A/2P MAIN BREAKER (TOP FED) CELL WIRE LESS THESE DRAWINGS ARE SUBJECT TO MODEM COMMS COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR IQ GATEWAY WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (11)IQ8PLUS-72-2-US 2-Q cable(AWG#12,SKU:Q-12-RAW-300,THHN) MICROINVERTERS 1-#8 AWG,BARE COPPER GROUND N)15A BRANCH-1 .� Current 11 CANADIAN 4NV ��� n Renew- SOLAR:CS6R-40OMS-H L (N)20.�. • = Engineering (11)IQ8PLUS-72-2-US — J(:N:)20 MICROINVERTERSA (N)2 A 2P PR ' CURRENT RENEWABLES TO UTILITY ENGINEERING INC. • • 1760 CHICAGO AVE SUITE BRANCH-2 . OVERHEAD J-13,RIVERSIDE CA 92507 11 CANADIAN N FEED PHONE(951)d05-1733 SOLAR:CS6R-400MS-HL wwwcRENGco CONTRACTORINFO 3-#8 AWG,THWN-2 1 -#8 EGC,THWN-2 IN 3/4"OR LARGER PVC CONDUIT E I CONDUCNDINGTOR EARS CODE C Z SYS9. CONDUCTOR #6 BARE COPPER ELEMENT ENERGY LLC. MODULE MANUFACTURER CANADIAN 7470 SOUND AVENUE,MATTITUCK, SOLAR C56R�OOMS- NEW YORK,11952 MODULE MODEL HL PH:(631)779 7993 services@e2sys.com MODULE(W) 400 Licence-ME-52689 MODULE PTC(W) 376.70 (MASTER ELECTRICIAN) NOTE: Licence-HI-67461 MODULE Is c(A) 13.85 (SUFFOLK HOME IMPROVEMENT) MODULE VDC(V) 36.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual MODULE Imp(A) 12.99 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH MODULE Vmp IV) 30.80 PROPER JUNCTION BOX AT EACH END PER 690.31A Permit Package TIMOTHY OBRIEN WIRE SCHEDULE STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 8.800KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT Photovoltaic System # EQUIPMENT WIRE LOCATION QTY. WIRE AMPACITY RATING (°C) FACTOR APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 1130 SALTAIRE WAY, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date A INITIAL DESIGN 4/4/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.31 0.96 1 28.80 16.64 3 AC COMBINER TO POI EXTERIOR WALL 3 8 55 90° 26.62 0.96 1 52.80 33.28 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY ER SHEET# PV-5.0 TITLE ELECTRICAL SLD MATERIAL LIST OF A o �P� pE MAN/ � ELECTRICAL EQUIPMENTS Uj D QTY. PART TYPE PART NUMBER DESCRIPTION yN 099128 22 MODULE CS6R-40OMS-HL CANADIAN SOLAR CS6R-40OMS-HL CTRIG 22 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US �SS►oNP� 1 COMBINER X2-1Q-AM1-240-4 ENPHASE COMBINER BOX X2-IQ-AM1-240-4 STAMPED OMOM2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewabk Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J.13,RIVERSIDE CA 92507 PHONE:(951)>05-1733 NNJW.CRENG.CO O BREAKER / FUSES CONTRACTORINF QTY. PART TYPE PART NUMBER DESCRIPTION 1 FUSES 40A FUSES GENERAL 40A FUSES la ® no 2 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) E2SYSA. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52669 (MASTER ELECTRICIAN) RACKING Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK Permit Package 8 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 TIMOTHY OBRIEN 48 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK 8.800KW Grid Tied STOPPER SLEEVE, 35MM, BLACK 8 CLAMPS & GROUNDING UFO-STP-35MM-B1 Photovoltaic System 2 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 44 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK 1130 SALTAIRE WAY, MATTITUCK,NY 11952 88 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev Description Date 44 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-6.0 TITLE BOM EXISTING SERVICE PANEL PHOTOS OF NCiv. MA/Vjp CO,p,lk m 28 'L oss1 2 CTRICP� V Ro�SS1 STAMPED 04/04/2024 A u rtok THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current i R f� 1 _1�'1 � llif Renew-Wes _= Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CH ICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE'(951)-405-1733 WWW.CRENG.CO CONTRACTOR INFO �r t EZSYSA "^ ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 ' - PH:(631)779 7993 � - services@e2sys.com 3 - Licence-ME-52689 li (MASTER ELECTRICIAN) { Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package TIMOTHY OBRIEN 8.800KW Grid Tied Photovoltaic System 1130 SALTAIRE WAY, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 i DRAWN BY E.R SHEET# PV-7.0 TITLE ELECTRICAL PHOTOS OF NEIV M A Ni�cOUj PHOTOVOLTAIC SYSTEM, •p Y 099128 w EQUIPPEDRAPID" D• 2 ��� � crR1cP� �C9 v 690.12 O�SS10r1P STAMPED 04/04/2024 D RAPID SHUTDOWN THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS TURN RAPID •V SYSTEM / DISCONNECT EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT JJSHUTDOWN SWITCH TO RATED AC OUTPUT CURRENT 26.612 ' RENEWABLES ENGINEERING INC. THE "OFF" POSITION TO AC AC NORMALOPERATING VOLTAGE240 VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 In Current AND REDUCE SHOCKLu _ Renew, HAZARD IN THE ARRAY NING" Engineering PM DUAL POWER SOURCES 690.56(C)(1)(B) CURRENTRENEWABLES SECOND SOURCEIS PHOTO- VOLTAIC ENGINEERING INC. OUTPUT 1760 CHICAGO AVE SUITE RATED AC • • J-13,RIVERSIDE CA 92507 PHONE.(951)-405-1733 1 NORMAL OPERATING VOLTAGE / ' VOLTS NWUW.CRENG.CO CONTRACTORINFO 690.54 OPTIONAL SOLAR LOAD CENTER ARRAY E2SYS8U ELEMENT ENERGY LLC. J/B 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 L services@e2sys.com • — Licence-ME-52669 INVERTER OUTPUT CONNECTION (MASTER ELECTRICIAN) Licence-HI-67461 • NOT ' • NEC 690.31(G)(3)&(4), CRC R324.7 (SUFFOLK HOME IMPROVEMENT) OVER-CURRENT DEVICE SOlar Individual Permit Package (UNLESS BUSBAR IS FULLY RATED) 705.12(D)(2) PHOTOVOLTAIC POVVER SOURCE TIMOTHY OBRIEN EVERY 10'ON CONDUIT AND ENCLOSURES 8.80OKW Grid Tied Photovoltaic System NOTES: 1130 SALTAIRE WAY, 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS MATTITUCK,NY 11952 SHOWN HEREON. Rev Desuiption Date 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN 4/412024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE OPPORTUNITY TIMOTHY OBRIEN WORK. PROJECT# 9002 DATE DRAWN 4/4/2024 C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY ER THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-8 0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. OF NEINY MA/y7R 0 � � D w m izs w Z�v z CTRIG V ssolt CAUTION STAMPED 04/04/2024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. PV ARRAY Current R Renew _- Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE } J-13,RIVERSIDE CA 92507 Q PHONE.(951)-405-1733 WWW.CRENG.CO LU CONTRACTOR INFO Q N CZSYS9 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com MAIN SERVICE PANEL Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 COMBINER (SUFFOLK HOME IMPROVEMENT) UTILITY METER Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL TIMOTHY OBRIEN PANEL IS AC DISCONNECT PER NEC690.17 8.800KW Grid Tied Photovoltaic System 1130 SALTAIRE WAY, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-8.1 TITLE PLACARD MICROINVERTER CHART 1 -10 1 1 -20 21 -30 31 -40 41 -50 51 -60 C UM 1 MSP 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 0� n Current Rene . hies Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE(951)-405-1733 WWWCRENG.00 CONTRACTORINFO 5 � ® n EZSYSU ELEMENT ENERGY LLC. 6 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package TIMOTHY OBRIEN 8.800KW Grid Tied$ Photovoltaic System 1130 SALTAIRE WAY, MATTITUCK,NY 11952 Rev DescnpYiorl I Date A INITIAL DESIGN I 4/4/2D24 9 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY ER 10 SHEET# PV-9 0 TITLE MICROINVERTER CHART SAFETY PLAN DM MARK UP KEY MSP INSTRUCTIONS: COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. MSP MAIN SERVICE PANEL EXPRESSLY FORBIDDEN WITHOUT PRIOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN RENEWABLES ENGINEERING INC 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE M UTILITY METER &MAKE NOTES ON THE JHA SHEET OP PERMANENT ANCHOR 0� n Current IN CASE OF EMERGENCY Renewakles uJUNCTION BOX Engineering NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC TO TEMPORARY ANCHOR CURRENT RENEWABLES NAME: ENGINEERING INC. ADDRESS: IL INSTALLER LADDER 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 S❑ STUB-OUT WWW CRENG CO SAFETY COACH CONTACT INFORMATION CONTRACTOR INFO NAME: ® SKYLIGHT ADDRESS: 0 don& ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE ❑ ��LADDER�` �AL��S STEEP GRADE CZSYS� SAFETY PLAN AND SIGN INDICATING THAT THEY ARE �VtC'6N&Ttl17 P t"'(ACCESS AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR CONDUIT WORKING SAFELY. ELEMENT ENERGY LLC. GAS GAS SHUT OFF 7470 SOUND AVENUE,MATTITUCK, NAME SIGNATURE NEW YORK,11952 zo WATER SHUT OFF PH:(631)779 7993 services@e2sys.com OLicence-ME-52689 SERVICE DROP (MASTER ELECTRICIAN) Licence-HI-67461 OPOWER LINES (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package TIMOTHY OBRIEN 8.800KW Grid Tied Photovoltaic System 1130 SALTAIRE WAY, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 4/4/2024 DATE: TIME: OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel,and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all The site supervisor shall forecast the weather conditions at the Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below). If client does not give THESE DRAWINGS ARE SUBJECT TO secured to the structure. Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS uneven, loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. I RENEWABLES ENGINEERING INC. the ladder must extend 36"above the stepping off point. Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. Elevated work involving the moving or maneuvering of solar If Offsite,add location name and address: bars locked in the open position,A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind tj Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure leaned a ainst a structure). Workers. Forecasted weather maximum temp(degrees F): Contact your Site Supervisor B Renew•: • Additional notes: Crew leader responsible for Communication with the client: Engineering Name: Mobile Equipment • Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment,operators must Yes,No): Heat Related Illness Prevention Phone: CURRENT RENEWABLES maintain a certification on their person for the equipment bein Employees shall have access to potable drinking water that is ENGINEERING INC. P9P 9 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13,RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE (951)-405-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: WWW CRENG CO P l 9 P 1 PP 4 Y 9 9 • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift. Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to Client,personnel or public, Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: Idum ,,...,� • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees CZ SYS Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description work is complete;a fall rescue plan must be outlined and Crew member(name/title): New employees must be acclimatized. New employees will be of what happen and when. ELEMENT ENERGY LLC. discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two 7470 SOUND AVENUE,MATTITUCK, • First-person-Up(FPU)must install their anchor and connect Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE NEW YORK,11952 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) PH:(631)779 7993 Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift. Employees must take services . com Licence--ME-5E-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do (MASTER ELECTRICIAN) • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-HI-67461 • Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an I TIMOTHY OBRIEN electrically safe condition(de-energized)unless approval has • If yes, list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 8.800KW Grid Tied • Service drops and overhead electrical hazards will be If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident: indentified and protected from contact as neccessa water(location/address): Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 1130 SALTAI RE WAY, MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Desaiption Dale A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-11.0 TITLE SAFETY PLAN AMI& _� CanadianSolar CS6R-40OMS-HL/I-V ENGINEERING DRAWING(tom) A A Rear View Frame Cross Section A-A t. 14 A-A t3 13 Gas _ 35 _ 11 . 11 -- 10 10 9 91 THESE DRAWINGS ARE SUBJECT TO s� s_ _ _ COPYRIGHT PROTECTION BY US LAW. _ _ - t7 71 7 _ REPRODUCTION IN ANY FORM IS EKPRESSLY FORBIDDEN WITHOUT PRIOR 5 i s _ __ WRITTEN APPROVAL FROM CURRENT 4 4 - RENEWABLES ENGINEERING INC. Mounting Hole 2 i 2 P 0 5 10 15 20 2S 30 35 40 45 SO SS eO S 10 15 20 25 30 35 40 45 50 SS 60 v � Current _ - la n000wmr 5•r 0 1 -� Renewables H i Ku6 (All-Black) a Wowt,,r 25-L S = Engineering 10B1 o wm 45- a 9 _ 0 400WIm' 65•C W ALL BLACK MONO PERC 2mwft• C JRRENT RENEWABLES E VGINEERING INC. ELECTRICAL DATA I STC* MECHANICAL DATA iiiW CHICAGO AVE SUITE 380 W - 405 W CS6R-380/385/390/395/400/405MS-HL Specification Data J-13,RIVERSIDE CA 92507 ---- - - ---- PHONE(951(d05-1733 CS6R-380 1 385 1 390 1 395 1 400 1 405 M S-H L Nominal Max.Power(Pmax) 38O W 385 W 390 W 395 W 40O W 405 W Cell Type Mono•crystalline AWW CRENG CO Opt Operating Voltage(Vmp)30.0 V 30.2 V 30A V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X 6)] CONTRACTOR INFO Opt Operating Current(Imp)12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A 1722 x 1134 x 35 mm """� Dimensions ZS Open Circuit Voltage(Voc) 36.0 V 362 V 36A V 36.6 V 36.8 V 37.0 V (67.8 x 44.6 x 1.381n) MORE POWER Industry Leading Product warranty on Materials Years t` and Workmanship* Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 22.4 kg(49.4lbs) Module Efficiency 19.5% 19.7% 20.0% 202% 20.5% 20.7% Front Cover 3.2 min tempered glass with anti-ref- Module power up to 405 W lective coatino 4.w..� Max.Oper sysg T Voltage 1 OOOV ECIU Frame Anodized aluminium alloy, C 2 SYSFF 4A5 W Module efficiency up to 20.7% Max S Volta 1000V(IEC/UL) - � 6 25 : Linear Power Performance Warranty* y -_ J-Box IP68,3 bypass diodes u Years Module Fire Performance TYPE 2(UL aEC 61 3 0V) Cable 4 mm'(IEC),12 AWG(UL) ® or CLASS C(IK 61730) Lower LCOE&system cost 11 year power degradation no more than 2% Max Series Fusee Rating 25 A Connector T6,MC4,MC4-EV02 or MC4-EY02A ELEMENT ENERGY LLC.Subsequent annual power degradation no more than 0.55% 7470 SOUND AVENUE,MATTITUCK, Application Classification Class A Appi Cable Length 1560RYn(61A m kt)(+)/1100m(433in)(),, NEWYORK,11952 *Sub**to the terms and conditions contained in the applicable Canadian Solar Limited Power Tolerance 0-+10 W (1�ud� onr ectoo _ PH:(631)779 7993 Warranty Statement.Also this 25-year limited product warranty is available only for prod- /' Comprehensive uctsinstalledandoperatirgwresbmualroofopsincertainregiats *Under Standard Test CondMon,;(STC)ofirradianceof1000WW,spectrum AM1.5 and cNltempe- Per Pallet 30pieces services@e2s ys.com servi om technology,up to 50%lower degradation .........................•..............---..........---.........--....---......•---........................-••• ratureof25°C. Per Container(40'HQ)780 pieces Licence-ME-52689 MANAGEMENT SYSTEM CERTIFICATES* *For detalled information,please contact your local Canadian Solar sales and (MASTER ELECTRICIAN) IS09001:2015/Qualitymanagememsystem technicalreprexrrcawe5. Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Better shading tolerance 1SO14001:2015/Standards for environmental management system ISO 45W1:2018/International standards for occupational health&safety ELECTRICAL DATA I NMOTt Solar Individual TEMPERATURE CHARACTERISTICS PRODUCT CERTIFICATES* CS6R-380/385/390/395/400/405MS-HL Specification Data Permit Package MORE RELIABLE IEC 61215/IEC 61730/CE Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W CEC listed(US California)/FSEC(Us Florida) Opt Operating Voltage(Vmp)28.1 V 283 V 28A V 286 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0"34%/°C UL61730/IEC 61701/IEC 62716 - ---_----- --- TIMOTHY OBRIEN Take-e-way Opt Operating Current(Imp)10.12 A 10.19 A 1026 A 1033 A 1039 A 10.45 A Temperature Coefficient(V00 -0.26%/°C Q Minimizes micro-crack impacts �= Open Circuit 33.9V 34.1V 34.2V 34AV 34.6V 34.7V Temperature Coefficient(1%) 0.05%/*C dE SA 0)U�O - 8.800KW Grid Tied c us( E Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A Nominal Module Operating Temperature 42±3°C*The specific certificates applicable to different module types and markets will vary, *Under Nominal Module Operating Temperature(NMOT),irradiance of 900 W/mispecbum AM 1.5, Photovoltaic System Ste m *** Heavy Snow load Up t0 8100 Pa, and therefore not all of the certifications listed herein will simultaneously apply to the ambient temperature 20°C,wind speed 1 m/s. products you order or use.Please contact your local Canadian solar sales representative PARTNER SECTION p wind load up to 5000 Pa* to confirm the specific certificates available for your Product and appliciible in the regions 1130 SALTAIRE WAY, in which the products will be used. MATTITUCK,NY 11952 ............................................................................................................................. CSI SOLAR(USA)CO.,LTD.is committed t0 providing high quality i Rev Description Date solar photovoltaic modules,solar energy and battery storage solutions to 4 INITIAL DESIGN 4/412024 customers.The company was recognized as the No.1 module supplier for *The specifications and key features contained In this datasheet may deviate slightly from our actual quality and performance/price ratio in the IHS Module Customer Insight products due to the on-going innovation and product enhancement.Csl solar Co.,Ltd.reserves the i tight to make necessary adjustment to the information described herein at any time without further Survey.Over the past 20 years,it has successfully delivered over 70 GW notice. O-PORTUNITY TIMOTHYOBRIEN *For detailed information,please refer to the Installation Manual. Of premium-quality solar modules across the World. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using PROJECT# 9002 ................................... ..-............. ...........--.......-... .............. ............... .- ............ ............................................ ................ ...................... our PV modules. ................................................._.................................._............................. D4TEDRAWN 4/4/2024 CSISOLAR(USA)CO.,LTD. ..............."....................................»...................._..."...................._.........................................................".-.................... DRAWN BY ER _....._....._.-......_..................._........................... AugI 9 I J 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94598,USA I www.csisolar.com/na service.ca@csisoiar.com CSI SOLAR(USA)CO.,LTD. 2022 All rights hts reserved PV Module Product Datasheet v1.1C25_F23 1_NA siEET# Pv-1z o T TILE MODULE SPEC lawENPHASE. IQ8 and IQ8+ Microinverters Commonly toad modide pairings' W 235-350 235-440 Module compatibility _ To meet compatibility,PV modules must be within maximum Input DC voltage and maxYnun rmdids Ir listed babes. Module compatibility can be checked at hops://enphase.com/installers/mictokvvwtwVcakxdator MPPT voltage range V 27-37 27-48 -- THESE DRAWINGS ARE SUBJECT TO Operating range V �'� 18-58 COPYRIGHT PROTECTION BY US LAW Minimum/Maximum start voltage V 22/48 22/58 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Maximum input DC voltage V 50 80 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Maximum module I A 20 _— Current Overvoltagia class DC pat - tl Renewables Dc port backfeeecurrent mA D Engineering PV array configuration - 1.1 ungrounded array,no additional DC side protection required;AC side protection requires maximum 20 A per branch circuit. CURRENT RENEWABLES Peak output power VA 245 300 ENGINEERING INC. 1760 CHICAGO AVE SUITE Maximum continuous output power VA 240 290 J-13.RIVERSIDE CA 92507 PHONE.(951)-405-1733 Nominal grid voltage(L-L) V 240,split-phase(L-L),IW WWW.CRENG.CO IQ8and IQ8+ Microinverters Easy to install Mil ut and Madmnt grid voltsi V 211-264 CONTRACTORINFO Lightweight and compact with plug- Metdmuncotltinwtsculputaarslt A 1.0 121 Our newest IQ8 Microinverters are the ind ustry's first microgrid-forming,software-defined and-play connectors microinverters with split-phase power conversion capability to convert DC power to AC Nominal frequency Hz 60 power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power luteomponent communication(PLC) Extended f y propr ry equency range Hz 47-68 between components application-specific integrated circuit(ASK;),which enables the microinrerter to operate in rid-tied or Off rid modes.This C is built using advanced 55-nm t with high-speed AC short-circuit fault current over g -g hip rig grid events. ia speed Faster installation with simple two wire Arms 2 ��� three cycles _ digital logic and has superfast response times to changing loads and grid events.alleviating cabling constraints on battery sizing for home energy systems. Maximum units per 20 A(L-L)branch _ 16 13 circuit= High productivity and reliability --- Totalharmonicdistortion % x5 ELEMENT ENERGY LLC. Produce power even when the grid is 7470 SOUND AVENUE,MATTITUCK, down' Overvoltage class AC port - III • _, NEW YORK,11952 More than one million cumulative hours AC portbackfeed current mA 30 PH:(631)779 7993 of testing Pavel factor real _ 1.0 a Licence-1 ME 52689 Class II double-insulated enclosure -- - - -- — Grid-tied power factor(adjustable) - 0.85 leading...0.85 lagging (MASTER ELECTRICIAN) Part of the Enphase Energy System, IQ8 Series Microinverters redefine Optimized for the latest high-powered Peak efficiency % g77 Licence-HI-67461 . IQ8 Series Microirtverters integrate with the reliability standards with more than one PV modules (SUFFOLK HOME IMPROVEMENT) IQ Battery,IQ Gateway,and the million cumulative hours of power-on CEC weighted efficiency % 97 Enphase App monitoring arid analysis testing,enabling an industry-leading Micr rid-formi Solar Individual software. limited warranty of up to 25 years. � � Nighttime power consumption mW 23 25 Compliant with the latest advanced Permit Package grid support•• • Ambient temperature range -40"C to 60`C(-40°F to 140"F) Remote automatic updates for the TIMOTHY OBRIEN latest grid requirements Relative humidity range 4%to 100%(condensing) • Configurable to support a wide range DC connector type MC4 aw::cof grid profiles — ------ - -._ ____ 8.800KW Grid Tied 0 Dimensions(H-W-D) 212mm%Z in)-"Snm'(62 In)a30.2mm0.2kt) Photovoltaic System 9 9 Connect PV modules quickly and easily I08 Series Microinverters are UL Listed ' Meet CA Rule 21(UL 1741-SA)and IEEE* Weight 1.08 k (2.38 Ibs) Y to I08 Series Microinverters 1547:2018(UL 1741-SB 31d Ed.)using the as PV rapid shutdown equipment and _�-- --- -�- ----- - ----- -_--- �-----_-�--- ---_-- included Q-DCC-2 adapter cable with conform with various regulations,when Cooling Natural convection-no fans 1130 SALTAI RE WAY, plug-and-play MC4 connectors. installed according to the manufacturer's NOrE: Approved for wet locations Yes MATTITU CK,NY 11952 instructions. -' • 108 Micranveners cannot be mixed with Pollution degree PD3 Rev Description Dale pavans generatans of Enpluse mkrdnveners (IO7 Series.106 series.and so,on)o the same Enclosure Class II double-insulated.corrosion-resistant polymeric enclosure A INITIAL DESIGN 4/4/2024 - • IQ Gateway is required to change the default Environmental category/UV exposure rating NEMA Type 8/Outdoor 'Mbets UL 1741 only when Installed with l0 System Controller 2. grid profile at the time of instal ation to meet -'108 and 108-support spla-phase•240 V installatipn only. local Authority Having Jurisdiction(AHJ) OPPORTUNITY TIMOTHY OBRIEN requirements. (17 No enlaces DC/4C r.tq PROJECT# 9002 O 20M Enphase F.rorgy.All rights reserved Enphasa,the a and CC logos.10,and certain other marks listed at cz)r« �.,.orcarn,.nP.un Be a.t tided seimd mrn.,.I n rewired Irvin•Nary. htuni/enphase.eom/trademark-usage-ouidellnes ere trademarks of Erwhase Energy.Inc.in the us and other countries.Data subiaet to change. IOSSP-I2A-DSH-00207-2.0-EN-US-2023-ICI-13 I08SP-12A-DSH-00207-2.0-EN-US-2023-10-13 DATE DRAWN 4/412024 DRAWN BY E.R SHEET# PV-12.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER IQ Combiner 4 IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20 t 0.5%) X-IQ-AM1-240-4 and consumption monitoring(t 2.5%).Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to X2-IQ-AMt-240-4(IEEE 1547:2018) deflect heat. IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20 t 0.5%) X-IQ AMt-240-4C and consumption monrtoring(t 2.5%).Includes Mobile Connect cellular modem(CELLMODEM-Mt-06-SP-O5),a plug-and-play i Q Combiner 4/4C The IQ Combiner 4/4C with IQ Gateway and industrial-grade cell modem for systems up to 60 microinverters (Available in the US,Canada,Mexico.Puerto Rico and the 1 HESE DRAWINGS ARE SUBJECT TO Y X2-IQ-AMt-240-4C(IEEE 1547:2018j US Virgin Islands.where there is adequate cellular service inthe installation area)Includes a silver solar shield to match the COPYRIGHT PROTECTION BY US LAW. integrated LTE-M1 cell modem (included IQ Battery and IQ System Controller and to deflect heat PIEPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR only with IQ Combiner 4C) consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,Order separately) WRITTEN APPROVAL FROM CURRENT _.-._ ----_-_ _-__---- -.--.`_-__--- ---. __-- --_---__- ----------____. _ ______ _-_ RENEWABLES ENGINEERING INC. Supported microinverters IQ6,IQ7,and IQ8.(Do not mix IQ6/7 Microinverters with I08) interconnection equipment into a single Communications Kit enclosure. It streamlines IQ Microinverters and COMMS-CELL MODEM-M1-06 IncludesCOMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan ---- ------- CELLMODEM-M1-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan 1 Current storage installations by providing a consistent, CELLMODEM-M1-06-AT-05 -4GbasedLTE-M1 cellular modem with 5-year AT&T data plan _ Circuit Breakers Supports Eaton BR210.BR215,BR220,BR230,BR240.BR250,and BR260 circuit breakers ••{\n/} Rene w a UI e s e ENPHAM pre-wired solution for residential applications BRK-t0A-2-240V Circuit breaker,2 pole,1 OA,Eaton BR210Engineering BRK-15A-2-240V Circuit breaker.2 pole,15A,Eaton BR215 it offers up to four 2-pole input circuits and BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-24OV-8 Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support Eaton BR series busbar assemblyBRK-20A-2P-24OV-B Circuit breaker,2pole,20A,Eaton BR220B with hold down kit support ENGINEERING LES ENGINEERING INC. XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4i4C 1 160 CHICAGO AVE SUITE i XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) J 13.RIVERSIDE CA 92507 j PHDNE (951)305-1733 X 10-NA-HD-125A Hold-down kit for Eaton circuit breaker wrth screws VAIM CRENG.CO i Consumption monitoring CT A pair of 200A split core current transformers CONTRACTOR INFO Smart (CT-200-SPLIT/CT-200-CLAMP) ELECTRICAL SPECIFICATIONS Includes lO Gateway for communication and control Rating Continuous duty Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05),included only with System voltage 120/240VAC 60 Hz I I Combiner 4C Eaton OR series busbar rating 125A • Includes solar shield to match Enphase IQ Battery Max continuouscunentratrn9 65A C Z SYS9. aesthetics and deflect heat Max-continuous parent rating(input from PV/storage) 64A Supports Wi-Fi,Ethernet,or cellular connectivity Max fusercvcut rating(output! 90A ELEMENT ENERGY LLC. Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) 7470 SOUND AVENUE,MATTITUCK, Provides production metering and consumption Max total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included NEW YORK,11952 monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included PH:(631)779 7993 services@e2sys.com Production metering CT 200A solid core pre installed and wired to IQ Gateway Licence-ME-52689 Simple MECHANICAL DATA (MASTER ELECTRICIAN) - --- ----- --_— —- ------- - - - --- ---- ---- Licence-HI-67461 X-I0-AM1-240-4C Mounts on single stud with centered brackets Dimensions(WxHxD) 37.5 cm x 49 5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets (SUFFOLK HOME IMPROVEMENT) • X2-IQ-AM1-240-4C(IEEE 1547:2018) Supports bottom,back and side conduit entry Weight 7 5 kg(16 51bs) I Solar Individual Allows up to four 2-polebranch circuits for240VAC Ambient temperature range -40°Cto-46-C(-40°Fto1151F) Permit Package plug-in breakers(not included) Cooling Natural convection,plus heat shield BOA total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction TIMOTHY OBRIEN Wine sizes 20A to 50A breaker inputs.14 to 4 AWG copper conductors •60A breaker branch input,4 to 1/0 AWG copper conductors Reliable • Main lug combined output.10 to 2!0 AWG copper conductors 8.800KW Grid Tied Neutral and ground 14 to 1/0 copper conductors Photovoltaic System Durable NRTL-Certified NEMA type 3R enclosure Always follow local code requirements for conductor sizing y • Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) 1 Two years labor reimbursement program coverage 1130 SALTAIRE WAY, INTERNET CONNECTION OPTIONS included for both the IQ Combiner SKU's Integrated w-F ieEe eo2.1m/g/n -" ""---- --" - MATTITUCK,NY 11952 UL listed X-IQ-AM1-240a1 _ _._ _. . - Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-Mt cellular modem) Note that an Mobile Connect Pev Description Date X2-IQ-AMl-240-4 and X2-IQ-AMl-240-4C comply with cellular modem is required for all Enphase Energy System installations A INITIAL DESIGN 4/4/2024 X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 1547:2018(UL 1741-SB,3"Ed.) Ethernet Optional,IEEE 802.3,CatSE(or Cat6)UTP Ethernet cable(not included) COMPLIANCE lrri/ Compliance,IQ Combiner CA RUIe 21(UL 174E SA) GPPORTUNITY TIMOTHY OBRIEN IEEE 1547:2018-UL 1741 SB,3"Ed.(X2-IQ-AM1-240-4 and X2-I0-AM11-2404C) PROJECT# 9002 CAN/CSA C22.2 No.1071,Title 47 CFR,Part 15,Class B,ICES 003 Production metering.ANSI C12.20 accuracy class 0 5(PV production) LATE DRAWN aiarzo2a LIM E N PHAS E. Consumption metering accuracy class 2 5 CRAWN BY E R To learn more about Enphase offerings,visit Il phase. �� Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No 61010-1 SHEET# PV-12 2 IQ-C-4-4C-DS-0103-EN-US-12-29-2022 0 2022 Fnphase Energy All rights reserved Enphase,the Fnphase logo.IQ Combiner 4/4C,and other names are trademarks of TITLE Enphase Energy,Inc Data subject to change I0-C-4-4C-DS-0103-EN-US-12-29-2022 COMBINER SPEC AM& IRONRIDGE XR Rails Family XR Rail Family The XR Railc"Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Rails to match. Over their lifetime. solar panels experience countless THESE DRAWINGS ARE SUBJECT TO ' COPYRIGHT PROTECTION BY US LAW. extreme weather events. Not just the worst storms in years, REPRODUCTION IN ANY FORM IS but the worst storms in 40 years. High winds capable of EXPRESSLY FORBIDDEN WITHOUT PRIOR Y g p WRITTEN APPROVAL FROM CURRENT ripping panels from a roof, and snowfalls weighing RENEWABLES ENGINEERING INC enough to buckle a panel frame. w� — XR RailsA are the structural backbone �� Current preventing these results.They resist uplift, XR10 XR100 XR1000 protect against buckling and safe) �' J�n -lenewables P 9 9 Y XR10 is a sleek.low-profile mounting XR100 is a residential and commercial XR is a heavyweight among Engineering and efficiently transfer loads into the rail..designed for regions with light or mounting rail.It supports a range of solar mounting rails It's built to handle building structure.Their superior no snow It achieves spans up to 6 feet wind and snow conditions,while also extreme climates and spans up to 12 spanning capability requires fewer while remaining light and economical maximizing spans up to 10 feet. feet for commercial applications. CURRENT RENEWABLES roof attachments, reducing the 6 spanning capability10 spanning Capability 12 spanning capability ENGINEERING INC. P 9 P Y P 9 P Y nso cHICAGo AVE SUITE number Of roof penetrations Clear load capability Heavy load capability Extreme load capability J-13.RIVERSIDE CA 92507 • Clear&black anodized finish Clear&black anodized finish Clear anodized finish PHONE:(951)-405-1733 and the amount of Y., Internal splices available Internal splices available Internal splices available WWW CRENG CO installation time. CONTRACTOR INFO Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.` Values are based on the followingcriteria.ASIDE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B. Roof �- CZSYS,J Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. 0 Rail •• ELEMENT ENERGY LLC. --- 7470 SOUND AVENUE,MATTITUCK, IF • • NEW YORK,11952 Force-Stabilizing Curve PH:(631)779 7993 s0 services@e2sys.com P89 Sloped roofs generate both vertical and lateral 120 Licence-ELECTRICIAN) forces on mounting rails which can cause them to (MASTER ELECTRICIAN) bend and twist The curved shape of XR Railsa NUS Licence-HI-67461 is specially designed to increase strength in both 14� 17., XR1000 (SUFFOLK HOME IMPROVEMENT) directions while resisting the twisting.This unique feature ensures greater security during extreme 160 Solar Individual weather and a longer system lifetime 90 Permit Package 120 TIMOTHY OBRIEN 20 \� 140 f 160 8.800KW Grid Tied Photovoltaic System so 30 1130 SALTAIRE WAY, —` I 160 MATTITUCK,NY 11952 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 Pei De mpto Date XR Rails`are IronRidge"offers All XR Rails`are made of 6000-series s 40 INITIAL DESIGN 4/4/2024 Compatible with a range of tilt leg aluminum alloy.then protected with an 160 AFlashFoor`and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion.while also providing 80 160 attachments. applications. a more attractive appearance. _ OPPORTUNITY TIMOTHY OBRIEN 120 160 PROJECT# 9002 `Table is meant to be a Simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. DATE DRAWN 4/4/2024 DRAWN BY ER 2023 Inc.All nghtS reser�ed.Visit www.ironnd9e.corn or call •r r ,��_ TITLET# P1-12 3 RAIL SPEC //r IRON RIDGE QUICkMountg ® Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home,solar attachments • Am THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. A REPRODUCTION IN ANY COPYRIGHT PROTECTION BY US LAW. IS Due to recent innovations,many asphalt shingles ' " EXPREESSLY FORBID ENFORM WITHOUT PRIOR have bonded courses.A mount that protects without WRITTEN APPROVAL FROM CURRENT the need to pry shingles can really speed things up. r RENEWABLES ENGINEERING INC. Halo UltraGrip"(HUGS)is here to respect the roof. x Current Its Halo is a cast-aluminum barrier that encases the — =- UttraGrip,our industrial-grade,foam-and-mastic 0 R''IeWableS seal.This allows HUG to accelerate the installation — Engineering process and provide the utmost in waterproofing Hit the rafter? d to go! Miss the rafter7 Try it again. Still no luck?Install the rest. protection.Give your roof a HUG.' When • •a rafter,•••u can move on Place another , right CURRENT RENEWABLES Only 2 RD Structural Screws are -• rafter is found.install • •final screw secure six screws to deck mount it ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 PHONE:(951)A05-1733 WWW.CRENG.CO - HUG'uWiea multi-tiers fig CONTRACTOR INFO componenrts to provide revolutionary Trusted Strength & Less Hassle lrraterprooting protection The Halo cast- aluminum..raised-perimeter foundation Structural capacities of HUG$were reviewed in m the UMraGnp base-a foa - mastic seat combination mat many load directions,with racking rail running wa1ef witrus1on by adienrig cross-slope or up-slope in relation to roof pitch. with the shingle surface. HtraGrip-is part For further details,see the HUG Certification C 2 SYS6 uickMount' letters for attaching to rafters and decking. line. ELEMENT ENERGY LLC. -- 7470 SOUND AVENUE,MATTITUCK, h IronRidge designed the HUG, in combination NEW YORK,11952 UltraGrip"Seal T with the RD Structural Screw to streamline PH:(631)779 7993 services@e2sys.com HUG UlbaGrip utilizes a installs,Which means the following: Licence-ME-52689 art seal design that uses a (MASTER ELECTRICIAN) foam-and-mastic com NO In shingles Licence-HI-67461 foam-backed adhesive prying 9 entirely new flashing system No roof nail interference (SUFFOLK HOME IMPROVEMENT) conforms and adheres to !Product Year Warranty and cranny of composition guaranteed free No pilot holes necessary Solar Individual filling gaps and shingle - ' No sealant(in most cases) Permit Package (up to 1B"in height). • No butyl shims needed TIMOTHY OBRIEN Attachment Structural Water Seal UL 2703 8.800KW Grid Tied Loading Design Ratings System Photovoltaic System 1130 SALTAIRE WAY, Rafter&Deck Mounting Options MATTITUCK,NY 11952 The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG"to the roof rafters,the roof HUG has been and certified for the UL 441 Section UL 2703 mechanical Rev Description Date deck,or both with our custom-engineered A INITIAL DESIGN 4/4/2024 RD(rafter-or-deck)Structural Screw The RD tested and rated to compliance with 27"Rain Test"and and bonding Triple Rated&C.eAHied �►- Structural Screw anchors HUG to the roof support 1004(Ibs)of the International TAS 100(A)-95 requirements. See to Respect the Roof- - with an EPDM sealing washer,completing UL 2703,441 (27) the stack of waterproofing barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual OPPORTUNITY I TIMOTHY OBRIEN Intertdk TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. PROJECT# 9002 DATE DRAWN 4/4/2024 1 DRAWN BY ER Oc i ge, nc. , 1 SHEET# PV-12.4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward,CA 94545 Hayward.CA 94545 R O N R I D G E 1-800-227-9523 I R O N R I D G E 1-800-227-9523 IronRidge.com IronRidge corn Attn:Corey Geiger,COO,IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following: Date:September 7'",2021 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1 THESE DRAWINGS ARE SUBJECT TO Re:Structural Certification and Span Tables for the IronRidge Flush Mount System COPYRIGHT PROTECTION BY US LAW REPRODUCTION IN ANY FORM IS 2 Wind speed shall conform to ASCE 7-16 Fig 26.5-1 B(for Risk Category II)and applicable state&local EXPRESSLY FORBIDDEN WITHOUT PRIOR This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System The county/city amendments to the IBC. No special wind topographic features are included and both topographic WRITTEN APPROVAL FROM CURRENT contents of the letter shall be read in its entirety before applying to any project design The Flush Mount System is a coefficient(Kn)and wind ground elevation factor(Ke)are taken as 1.0. RENEWABLES ENGINEERING INC. proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface PV modules are supported by extruded aluminum XR Rails 3. Snow load used in the span tables is the ground snow and shall conform to ASCE specified Fig.7.2-1 and and secured to the rails with IronRidge mounting clamps The XR Rails are side mounted to a selected roof applicable state&local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the 'y-, Current L,� 9 P format of a flat roof snow it shall first be converted to a ground snow following the local building code/ r ReneWableS attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables. No special snow conditions are considered — Engineering that is fastened to the underlying roof structure Assembly details of a typical Flush Mount installation and its core including unbalanced..drifting,sliding, retention,or ponding snow.No rain-on-snow surcharge load is 9 9 components are shown in Exhibit EX-0015. considered The span tables do not apply to buildings which are intentionally kept below freezing,kept just above freezing,or unheated CURRENT RENEWABLES ENGINEERING INC. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 listed below,for the load conditions and configurations tabulated in the attached span tables. PHONE(951)-405-1733 (a)For ground snow no greater than 42psf:Ss<_2.Og for Site Class A,B,C,&D. WWW CRENG Co ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Ss s 1.0g for Site Class A,B,C,&D. CONTRACTOR INFO 2018 Intemational Budding Code(IBC-2018) (c)For ground snow between 42 and 65psf:S,<_1.5g for Site Class A,B,C,&D. 2020 Budding Code of New York State(BCNYS-2020,Published in November 2019) - 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients( Roof zones comprising each group along and 3 with each roof zone's size and location are depicted In Figures 2 and 3 below each span table. 01 The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall E 2 SYS the respective loads and configurations listed,covering wind exposure Categories B,C,& D,roof zones provided in be the lesser of the following two conditions.40%of the allowable span provided for the respective load ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8'to 45°. The tabulated spans are applicable when the &configuration condition from the span tables,or 36" ELEMENT ENERGY LLC. followingconditions are met 7470 SOUND AVENUE,MATTITUCK, 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over NEW YORK,11952 a minimum of three spans. PH (631)779 7993 1 Span is the distance between two adjacent roof attachment points(measured at the center of the services@e2sys.com attachment fastener) 8. No splices are allowed in the rail cantilever For each XR splice type install per the following requirements Licence-ME-52689 (MASTER ELECTRICIAN) a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2/3 of end spans. Licence-HI-67461 2 Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated b) BOSS Splice can be installed at any location within a span. (SUFFOLK HOME IMPROVEMENT) based on 2 rail systems.and conservatively deemed acceptable for 3 rail systems. 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded If Solar Individual 3. The underlying roof slope.measured between the roof surface and horizontal plane, is 80 to 450. such conditions are encountered contact support@ironridge.com. Permit Package 4 The mean roof height defined as the average of the roof eave height and the roof ridge height measured TIMOTHY OBRI EN from grade,does not exceed 30 feet. 8.800KW Grid Tied 5 A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the Photovoltaic System height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not exceed 10" 1130 SALTAIRE WAY, MATTITUCK,NY 11952 6. Module length and area shall not exceed the maximum values listed on the respective span tables. Rev De-npt— Date A INITIAL DESIGN 414/2024 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount Installation Manual and other applicable standards for the general roof construction practice. OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 2021 IronRidge Inc NY Flush Mount System Certification Letter-1 9 2021 IronRidge.Inc NY Flush Mount System Certification Letter-2 DRAWN BY E.R SHEET# PV-12 5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward,CA 94545 Hayward,CA 94545 406 IRONRIDGE lronRi ge.co23 IRONRIDGE 1onRid ecom3 IronRidge.com IronRidge com 10 Systems using CAMO module clamps shall be installed with the following guidance: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67.5", CAMO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater. Such consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting scenarios are shown by asterisks in the applicable span tables. members It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. THESE DRAWINGS HTPROTECTION ARE SUBJECT US To b) CAMO will function within a module's design load ratings.Be sure the specific module being used with COPYRIGHT PROTECTION BY US LAW. CAMO meets the dimensional requirements shown in the figure below and that the module selected is REPRODUCTION IN ANY FORM IS suitable for the environmental conditions of a articular project EXPRESSLY FORBIDDEN WITHOUT PRIOR P P J '-f Neyti, ^// 1 7 WRITTEN APPROVAL FROM CURRENT Sincerely, P�� N� X(� LO 2 O` 1 •O 9.O / RENEWABLES ENGINEERING INC tvloduleGlosslcels ` w - 1 5:45: 1 6 Current a ? — Renek, ����,g ?° - —07�00� �n EngineeYirg AO�ESS10Nt� --- home compofwtr. X=12 2.2mm CURRENT Y=15 40mm ENGINE IN C. LES Gang Xuan, PE 1760 CHI AGO AVE SUITE -------Y Senior Structural Engineer RIVERSIDE CA 92507 PHONE X PHONE'.(951)d05-1-1733 WWW.CRENG.CO Figure 1 CAMO Modute Frame Dimensional Requirements CONTRACTOR INFO Span values for Exposed and Edge module conditions,as defined below,are included in the attached span tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge ® .�'•� modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; (2)The span value determined by site wind speed and ground snow load.Additionally,irrespective of the lesser span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage EPSYS10 limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 1. Exposed Module conditions: NEW YORK,11952 PH:(631)779 7993 A module is defined as Exposed(per Section 29.4 4 of ASCE 7-16)if the distance from any of its free services . com Licence--ME-5E-52689 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave, ridge,rake.or (MASTER ELECTRICIAN) hip)is greater than 0-5h(h is ASCE defined building height)AND if the distance from its free edge to any Licence-HI-67461 other adjacent array or panel is greater than 4 feet- (SUFFOLK HOME IMPROVEMENT) Solar Individual The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed Permit Package Modules. TIMOTHY OBRIEN 2. Edge Module conditions: 8.800KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave,ridge,rake,or hip)is less than 2 times the height of the array(2h2) where h2 is measured from the roof surface to the top surface of the module 1130 SALTAIRE WAY, The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. MATTITUCK,NY 11952 Additionally, if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered Rev Description Date for this span adjustment. A INITIAL DESIGN 4/412024 OPPORTUNITY I TIMOTHYOBRIEN t 2021 IronRidge Inc. NY Flush Mount System Certification Letter-3 ©2021 IronRidge,Inc. NY Flush Mount System Certification Letter-4 PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY ER SHEET# PV-12.6 TITLE CERTIFICATION