Loading...
HomeMy WebLinkAbout50414-Z SFFU�� r Townf Southold job �oGy� of 8/7/2024 o P.O.Box 1179 o 53095 Main Rd 01 �ao� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45442 Date: 8/7/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1105 Westwood Ln, Greenport SCTM#: 473889 Sec/Block/Lot: 33.-2-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/26/2024 pursuant to which Building Permit No. 50414 dated 3/11/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Herbst,Frederick&Carolyn of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50414 7/30/2024 PLUMBERS CERTIFICATION DATED Aut 0r' Signature SOEroiKc TOWN OF SOUTHOLD a0 oGy ' BUILDING DEPARTMENT y :x TOWN CLERK'S OFFICE oy.• o� SOUTHOLD, NY col �a BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50414 Date: 3/11/2024 Permission is hereby granted to:, Herbst, Frederick 1105 Westwood Ln Greenport, NY 11944 TO' install roof-mounted solar panels and energy storage system (outside) to existing single-family dwelling as applied for. At premises located at: 1105 Westwood Ln, Greenport SCTM #473889 Sec/Block/Lot# 33.-2-5 Pursuant to application dated 1/26/2024 and approved by the Building Inspector. To expire on 9/10/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00-� Total: $325.00 Building Inspector pF SOUT��I 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q �. •Southold,NY 11971-0959 �o sean.deviina-town.southold.nv.us Q UNTN,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Frederick Herbst Address: 1105 Westwood Ln city:Greenport st: NY zip: 11944 Building Permit#: 50414 Section: 33 Block: 2 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunrun License No: 33878ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 11.34kW Roof Mounted PV Solar Energy System w/ (28) 405W ML G10 Hanwha Modules, 7.6kW Solaredge Inverter SE7600H USSN, Unfused AC Disconnect Notes: Solar- No Battery Storage Inspector Signature: Date: July 30, 2024 S.Devlin-Cert Electrical Compliance Form SOplyo� ` # # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 'o'-OtA42, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLA ON [ ] PRE C/O [ ] RENTAL REMARKS: asT •��5 // e ,vt �r �. �l.e tit..Ecc ss. 1ae DATE 5--d-,R INSPECTOR pF SO(/T �D ��f 6 l W C5�KJoj �, " # TOWN OF SOUTHOLD BUILDING DEPT.. co 631-765-1802 INSPECTION -. [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING . [ ] FRAMING /STRAPPING [ ] .FINAL [ ]. FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] 'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: la r P1 ckvi,5 8o mo- ma4( I vi Is , L C(f f dI.IX DATE . -INSPECTOR pF SOUTyOIo f # TOWN OF SOUTHOLD BUILDING DEPT. Coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL (6v/ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ -] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ -]. CODE VIOLATION [ ] P C/O [ ] RENTAL RE RKS: lcoqlAlll l DATE d4001INSPECTO OPSOUTyO� - ' c) gs # # TOWN OF SOUTHOLD BUILDING DEPT. CO 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ .] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [. ] FIRE RESISTANT PENETRATION, [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ��►, �A-� 1 1 1 00A DATE INSPECTOR OF SOGTyOIo 's o (- / # # TOWN OF SOUTHOLDB.0 LDING DEPT. ^o +,N 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH'PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] .FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ' /"ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O [ ] RENTAL REMARKS: DATE 0 LO- INSPECTOR /■' MIGHTY ■ ENGINEERING CO. DRIVEN TO EXCEED EXPECTATIONS �(2'' D ECEOWE May 03,2024 MAY 2 4 2024 Subject: Post Installation Approval Letter Building Department Town of Southold Job Number: 216R-105HERB Client:FREDERICK HERBST Address: 1105 WESTWOOD LN, GREENPORT,NY, 11944 Building Permit: 50414 To Whom It May Concern The purpose of the review was to verify the installation is in conformance with the approved plan set and that any potential modifications from those plans meet the intent of the approved plan set. I certify that the PV racking system's attachments have been observed to be installed in conformance with the approved plan set. The installation complies with the code provisions listed below. -Applicable Codes=2020 NEW YORK STATE RESIDENTIAL CODE WITH 2O18 IRC/IBC/IEBC, ASCE 7-16 and 2018 NDS • Basic Wind Speed V= 128 mph,Exposure:B • Ground Snow Load=25 Psf Sincerely, OF NE r� � w Digitally signed r y�P y `�"J" by Humphrey K. � Kariuki m 095450 ��_ �-Date2024.05.03 AR0 SSA°NPR 11 :51 :35 -04'00' Mighty Engineering Co 11708 Roxborough Rd Charlotte,NC 282111 (980)689.9776 info@mightyengineeringco.com FIELD INSPECTION REPORT DATE COMMENTS ro t� FOUNDATION (IST) -------------------------------------- CIO FOUNDATION (2ND) m z 0 ROUGH FRAMING& PLUMBING i r INSULATION PER N.Y. STATE ENERGY CODE •a•aPosh ona4,// „4,L see Tesbe, spa OF wQ-s ,� • eGh. t�a�iCe 7 ¢ss . ,b4 �. FINAL oov ADDITIONAL COMMENTS .� • a Posh irs�c./ cif ' o �rus. o Z s �� O x ro TOWN OF.SOUTHOLD•-.BUILDING DEPARTMENT Town Hall Annex 54375 Main Road:P.-6-i3ox 1179 Southold,:NVY 11971-0959 ( ) (. ) ttp Y> •Tele hone 631 7b5-1802 Fax: 631 765-9502 h s//www.southoldtownn . ov Date Received' APPLICATION::FOR BUILDING PERMIT : . :: : ,Nil- For Office Use.Only } PERMIT NO. Building Inspector:'' :�<< 2024 � . :'. :.. Applications:and forms must be filled out in-their entirety.lncQmplete. :applications will not be accepted. Where the Applicant is not the owner,an', . - Owner's Authorization'form(Page 2)shall be completed.. :.: Date: OWNER(S OF PROPERTY:'.: 00- :' SCTM#10 .d -��_ �(�= � Name: �°�___er�c_lc� `: y _s_. ___: :_:__. :�_________ __. �__ _ _ _._._�_.__ ::Project.Address: L Phone I SAO- #: .: _ Email:. ' : ... :Mailing AddreSLVaILIM. ' CONTACT PERSON: Name: : Mailing Address: �� Phone#: J/(�._aZ�� - • __ _ ::Email: DESIGN PROFESSIONAL INFORMATION: Name: • N/ : :.. Mailing Addre s: - Phone:#'. - G Email CONTRACTOR INFORMATION: :': : ' :Name:'. �• •.�� / � Mailing Address: '. : :.. Pho.ne.#: 6. Email: DESCRIPTION.OF PROPOSED CONSTRUCTION.. El New Structur dition ❑Alteration ❑Repair ❑D.em lition Estimated Cost of Pro*ect: er___r_-____ <3 S ar�els, ASS. ://. 3�(S,fC - _q i - Cam: Will the lo re t.6e -graded? ❑ : o:Yes -. .'.Will excess fill be remoVed from prernisEy "e �s ® 1 :. . PROPERTY INFORMATION ..Existin use of pro e g� p p rty: .•� . . . . .!'/ . Intended use of.p"roperty: Lag Zone or use district in'which premises is situated: Are there any covenants an restrictions.with:respectto- this property? DYes .., o IF YES,PROVIDE A COPY. Check Box After Reading::The owner/contractor%design professional is responsible for all drainage and.stornr water Issues as provided by- ... Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Bullding.DepartrWent'for the issuance of a.Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with'all,applicable laws,ordinances;building code, housing code and regulations and.to admit authorized inspectors"on premises and in bu lid[ng(s)"for necessary inspections.False statements made hereIna re 'punishable as a Class A misde'rneanor'pursuant to Section 21b.45 of the New York State.Penal Law.. :Application Submitted By(point name): ';Sf{rLeQ uthoriied Agent Owner: Signature'of Applicant: , :. :. Date: STATE OF NEW YORK) :.. ::" :: " COUNTY OF FLIPbeing duly sworn, deposes and says that(s)he is:the:applicant (Name of individual:signing contract),above named, )he:is the i Contractor,Agent; orporate Officer,etc.. :' . . . . . . . . of said owner or owners,and is duly authorized top rm:or:Iiave performed the said work and to:make.and file this application;that all statements contained in this application are true.to the best of his/her knowledge and belief;:anii: ; .. :. .. :. .. . that the work will be performed in the manner set forth in the application file therewith.:.. :: :: :.. .... :: Sworn before me this,\\��llillir""�,�,� day ofc �'� =;= 20 `/..: . " .. �• 3 J33 '.; Notary Public .PROPERTY OWNER-AUTHORIZATION: (Where the applicant:is not the owner.) residing;at: ��. �(LS . do hereby.authorise `11 r./��.�v/ .. t . .5M _1Z_ /V G (�7�Lf�Ito apply -n . my b o the Town of So Id Building Department.forapproval as described herein. L/ ,G : . 2 , Owner's Sig re Date Print Owner's Name: ... ... .. ... .... ... .... _. .... Z . UfFO( BUILDING DEPARTMENT-Electrical Inspector: == • •. TOWN. SOUTHOLD o* -, '• -. . . : Town Hall'Annex- 54375 Main Road - PO Box-1179• . -y - = ..•Southold,.New.York 11971-.0959 . O ::Telephone (631:) 765-1802 - FAX (631.) 765-9502 rogerr southoldtownny.gov�.seandCa)southoldtownny.gov,: :•APP.LICATION::F.OR:ELECTRICAL:INSPECTION. :.: ELECTRICIAN INF RMATION (All Information Required) Date: ZZZE . :.Com an Name:: : . Electrician's Name'._: License No.: `'� Elec. email:- InMllnh WnJ9- Elec: Phone No: 2 : CI�equest an email copy of Certificate,of Compliance Elec..Address.: / G JOB SITE INFORMATION ... ...o aired)Name.:.. .. :.Address: Cross Street: :. Phone,No.: .. BIdg:Pe'rmit#:... ..rj j}�/a f:: email: :. //. Tax Ma District: - 1.000, Section..* ,.: % Block: Lot: P BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE.(Please Print Clearly): CG1IVAl :: ::Square Footage: :Circle All That Apply::' Is job ready.for inspection?:- YES. O :: Rough.In Final ... Do you need,:a:Temp Certificate?:• :YES "v :Issued On Temp Information: . ' : ' (A.... '. q... ). ll information re aired ze Service Si 3 Ph Size: : .: A: #Meters:-: .: Old Mefer#.:� ❑1 Ph❑. , . . . ❑New Service❑Fire Reconnect❑Flood'Re'connect❑Service Reconnect❑Urnderground❑Overhead . . .. . .. #Underground L:aterals 1 •� �j- rame o.e Work don6-6hS6rVice'?­ Y .:. Additional Inforrimation:_.. . :..'PAYMENT DUEWITH APPLICATION ::'- �gufFOl� BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD ® =` l Town Hall Annex-.54375 Main Road - PO Box 1179 v' Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 � rogerr(a-southoldtownny.Qov— seand(a-southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INF RMATION (All Information Required) Date: ' Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No:_ - -52 DiKrequest an email.copy of Certificate of Compliance Elec. Address.: / '7 7G JOB SITE INFORMATION (All Information Required) Name: Address: ' w Cross Street: Phone No.: 2 )' Bldg.Permit#: f5Q CHt email: Q he 36) , Tax Map District: 1000 Section: Block: Lot: n L BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ,,I'Ms iz, J {'• Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES�O [:]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES E]-110 Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals M 1 2 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION `I p PERMIT# Address: Switches Outlets CFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments Y workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name$Address of Insured(use street address only) 1b.Business Telephone Number of Insured Sunrun Installation Services Inc. 202 Commerce Dr., Ste. 7 Moorestown, NJ 08057 1c.Federal Employer Identification Number of Insured Work Location of Insured(only required if coverage is specifically limited to 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box 1 a Southold, NY 11971 CG-52830-NY 3c.Policy Effective Period 11112024 To 12/31/2024 4. Policy provides the following benefits: 0 A.Both disability and Paid Family Leave benefits. ❑ B.Disability benefits only. ❑ C.Paid Family Leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as described above. - Date Signed January 02, 2024 By (Signature of insurance carrier's authorized representative or NYS licensed insurance agent of that Insurance carrier) Telephone Number 215-658-7318 Name and Tille Carolynn Smith -VP Contracts IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) IIIII IIIIIIIIIIIIIIIIIIDIIIIIIIIIIIIIIIIIIIIIIII�I�I DB 120.1 (12-21) PORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street Suite 1400 1c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-86426 4 Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e., 1d.Federal Employer Identification Number of Insured or Social Security a Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage(Entity 3a.Name of Insurance Carrier Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY Town of Southold Town Hall Annex Building 3b.Policy Number of Entity Listed in Box"l a" 54375 Route 25 P.O.Box 1179 WC 6142876-02 Southold,NY 11971 3c.Policy effective period 10/01/2023 to 10/01/2024 3d.The Proprietor,Partners or Executive Officers are Included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form Is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever Is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: MarkAlbi (Print name of authorized representative or licensed agent of insurance carrier) Approved by: i'1411a.rY&1 10-01-2023 (Signature) (Date) Title: VP/Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)946-7500 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov SUNRINC-02 TWANG ACORO DIYYYI� DATE(MM/D CERTIFICATE OF LIABILITY INSURANCE FDATE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER License#OC36861 CAONTAcr Walter Tanner Alliant Insurance Services,Inc. PA"//�NN E><t; jac,No): 560 Mission St 6th FI EMAIL San Francisco,CA 94105 .Walter.Tanner@alliant.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:Zurich American Insurance Company 16535 Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTRA X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE a OCCUR MKLVSENV104332 10/1/2023 1011/2024 DAMAGES(RENTED 1,000,000 PREMISE REM SES Ea occurrence) $ MED EXP(Any onePerson) 5,000 PERSONAL&ADV INJURY 21000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 2,000,000 X JECT LOC PRODUCTS $POLICY a 2,000,000 T X I OTHER:Retention:$200,000 Per Project Agg $ 51000,000 B AUTOMOBILE LIABILITY Ea accidentSINGLE LIMIT $ 2,000,000 Ix ANY AUTO BAP614287702 1011/2023 10/1/2024 BODILY INJURY Per ersonOWNED SCHEDULEAUTOS ONLYQ AUTOS BODILY INJURY Per accident $ �R pO p PROPERTY AMAGECCAUmTOuS ONLYAUT03 ONLY Peraccident $ $S u08 Ded.: Coll.:Not Covered Liability Ded.: $ 1,000,000 UMBRELLA IJAB HOCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DIED I I RETENTION$ C WORKERS COMPENSATION X PERTU OTH- AND EMPLOYERS LIABILfrY WC614287602 10/1/2023 10/1/2024 1,000,000 ANY PROPRIETOWPARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $ OFFICE R/MEM� EXCLUDED? N/A 1,000,000 (Mandatory in E.L.DISEASE-EA EMPLOYE If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Workers'Compensation Policy WC614287601 Deductible.$1,000,000. Evidence of Insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town ACCORDANCE WITH THE POLICY PROVISIONS. Route Southold,NY 11971 AUTHO/RIZED REPRESENTATIVE ,� ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD /1!M I.GHT1f :. ENGINEERING:CO. .. .. January 17,2b2.4 MA � RE -CERTIFICATION LETTER: Project Address::: HERBST RESIDENCE 1105"WESTINOOD LN :GREENPORT,NY;11944: Design Criteria: Applicable Codes.=2020"NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and.2018 NDS;; .-:Risk Category=II" :. :. •-Wind.Speed.=.128mph,Exposure.CategoryB;Partially/Fully Enclosed Method • • • .. Ground Snow Load=25 psf . . -ROOF AR-01 :2 x 8 @ 16"OC,Roof DL =8 psf,Roof LUSL=19.psf'(Non PV),Roof LUSL=13.8 psf(PV) =ROOF AR-02:2 x 8•@ 16":OC,Roof DL=8 psf;Roof_LUSL=18 psf(Non.P Roof LUSL=9.7 psf.(PV): ;; ... " .fir . -:ROOF AR-03:2 x'10 @ 24"OC,Roof DL=8"0sf,:R6of LUSL=20 psf Non-PV);:Roof LUSL=20 psf P To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. : . . .. . . . . .. . : .- Existing roof structural framing has been reviewed:for.additional loading due to installation of PV Solar System on;the roof.The structural review'applies to the sections of roof that is directly supporting the solar PV system: Based on this evaluation,I certify that the alteration to the existing.structure by installation of the PV system with sistering under AR-01 • meets the.proscriptive compliance requirements of the applicable existing building and/or new:building provisions adopted/referenced . . .. above.: .. Additionally,the.P.V.module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications•and,to meet and/or exceed the;requirements set forth by:the referenced codes: " : . : .. . . :OCCUPANCY OR Sincerely,. : 0E IS UNLAWFUL:. ED. . :.. ., m ptov NNEJW O� �-DD aIgIta=llysigned .. . . .. IC AT bmphrey KAS:NOTED OCCUPANCY/ ar A�PP .0117DATE! a s : .. R� ss,oNP` .: 05'00' .: . ., FEE : NOTIFY.BUILDING DEPARTMENT AT 631a65-1802:8AM TO 4PM FOR:THE: COMPLY WITH ALL CODES OF FOLLOWING INSPECTIONS: :".�. : : :-.NEW YORK STATE&"T01NN:GODE:S FOUNDATION:;-'TWO.REQUIRED ..AS REQUIRED AND CONDITIONS:OF � • FOR POURED CONCRETE. . 2. ROUGH r FRAMING&PLUMBING: SOUTHOLD"T N ZBA 3: INSuLATioN .. . ... .. : . '. .. . . . . SOUfHO " OWN PLANNING:BOARD . . OA :4:;: FINAL-CONSTRUCTION MUST SO(fTH EL�ECT'RICAL . . .. . TOWN TRUSTEES: �. BE:COMPLETE FOR C.O: . . N,Y.S EC : :.: ::.:9N .. Cat M Fl�EOU.IED.. . . . 9® ALL CONSTRUCTION SHALL MEET:THE REQUIREMENTS OFTHE"CODES OF NEW'.:. SO OLD HPC YORK STATE. NOT-RESPONSIBLE FOR DD i " " " borough"Rd 9 R9.9776 info@mi "ht•en ineerin co_com . . " " DESIGN"OT�•�ONS�TRI�CTK�ii�7 ER���" . .. . . � . .. g Y g .. g .. pgtiof9:": :: . SHEET INDEX LEGEND SCOPE-OF WORK GENERAL NOTES PAGE#. . . DESCRIPTION. SYSTEM SIZE:11340W OC,7600W AC ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE SE SERVICE ENTRANCE. MODULES:(28)HANWHA'Q-CELLS:Q.PEAK DUO BLK WITH 2018 IRC/IBC/IEBC;MUNICIPAL CODE';AND ALL MANUFACTURERS'LISTINGS _ -COVER SHEET'.... '.. PV-1.Q. •. •: ML=G1Q+405 :: : ': :: : : ANOINSTALLATION'INSTRUCTIONS.:: PV-2.0. .: SITE PLAN' .: MP .MAIN.PANEL INVERTERS:(1)SOLAREDGETECHNOLOGIES: PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. .: NEI1i. ❑. :. SE760OH-USSN ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. :. �P��OFKANU OQ PV-2.1 FLOOR PLAN: RACKING:RL UNIVERSAL, ON COMP; PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY 5 PE !i _ SP SUB-PANEL - PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436' GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. * •'$` LC PV LOAD CENTER ENERGY STORAGE SYSTEM:(1}TESLA:POWERWALL, :MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. : PV=3:1 REPAIR DETAIL 13,5KWh,5KW INVERTER OUTPUT.LITHIUM-IQN,L3/{TTERY INVERTER CONFORMS TO AND IS,LISTED UNDER UL 1741. n (WEIGHT:251.3LB EACH) "' .: .: S. RACKING CONFORMS TO AND IS LISTED UNDER UL:2703. 2 'PV-4.0 ELECTRICAL SM SUNRUN METER MAIN PANEL REPLACEMENT:EXISTING 200 AMP MAIN SNAPNRACK RACKING SYSTEMS;I.N COMBINATION.WITH TYPE I,,OR TYPE II .P.V=5.0 .SIGNAGE MAIN PANE 200 AM 095450 PANEL WITH2O0:AMP MAIN BREAKER TO BE REPLACED 'MODULES,ARE CLASS A FIRE RATED. PM DEDICATED PV METER WITH NEW 225 AMP M C WITH P;MAI_N ''RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL -p�FESSION BREAKER. CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER.NEC 690.12(1)... . BACKUP GATEWAY:'(1)'200ATESLA POWERWALL CONTROL CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).' INV INVERTERS) .. PANEL ARRAYDC CONDUCTORS ARE SIZED FOR DERATEDCURRENT. f �: .. AC STRUCTURAL UPGRADES REQUIRED ON AR-01.SEE DETAIL. 11.17 AMPS MODULE SHORT CIRCUIT CURRENT. ': : ': :DI Itd I I.•�51 - ned-�,: O AC DISCONNECT(S) 13.97 AMPS DERATED SHORT CIRCUIT CURRENT[696.8(A)&690.8(B)I. F., �' WESS ITH HALL 13E INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE by'Humphrey K. . ' a DC-DISCONNECT(S) . . . - - :: .. .. .. :ESS SUBJECT-TO VEHICLE IMPACT WILL BE PROTECTED BYAN APPROVED -a rI U ICI. CB IQ COMBINER BOX BARRIER IN ACCORDANCE WITH THE 2020 NEWYORK STATE RESIDENTIAL CODE." SECTION R327'9 AND THE 2020:FIRE CODE OF NEW YORK STATE SECTION 312,2:- ^f POWERWALL.ENERGY. ROOMS AND AREAS WHERE ENERGY STORAGE SYSTEMS ARE INSTALLED Date2024.0105 :SHALL BE PROTECTED ON THE SYSTEM SIDE-BY NO LESS THAN 5/8'INCH TYPE X'. STORAGE SYSTEM(ESS) :: _ -GYPSUM BOARD-OR EQUIVALENT,INSTALLED ONTHE WALLS AND CEILING OF : 10:4 '83O-05'00'. BG BACKUP GATEWAY THE ORK THE ROOM OR AREA IN ACCORDANCE WITH 020 NEW Y 'STATE ma RESIDENTIAL CODESECTION R327.8.: +::• ' w. - -- GP :GENERATION PANEL ENERGY.STORAGE SYSTEM CONFORMS'TO AND IS LISTED.UNDER UL 9540.. - ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING' ' ABBREVIATION& : ROUTINE MAINTENANCE.SYSTEM VOLTAGE IN ACCORDANCE WITH NEC 706.30 O -COMMUNICATION' AND EXCEPTION 1 NEC 706.30(A). A AMPERE WIRES ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE ENERGY AC ALTERNATING CURRENT un C - - - - - DEVICE ' . . CHIMNEY STORAGE INPUT AND OUTPUT TERMINALS ARE MORE THAN 5 FT FROM XM:':- ARCFAULi6lRCuiT:INTERUPTEa " ® :CONNECTED EQUIPMENT,OR WHERE THE CIRCUITS FROM THESE TERMINALS 'sunf ALM ; AZIMUTH •,•• ,; •' •.Q ATTICVENT: ' PASS THROUGH A WALL OR:PARTITION PER:706.7(E). as _ .LISTED,COMBINATION TYPEAFCI'SHALL BE INSTALLED WHERE BACKED UP COMP COMPOSRI,ON ; 0 FLUSH ATTIC VENT :" ;, CIRCUIT WIRING IS'EXTENDED MORE THAN 6FTAND DOES NOT INCLUDE ANY- DO .: DIRECTCURRENT: ,, .ADDITIONAL OUTLETS OR DEVICES PER NEC 210.'12(D). 00825-ME . Q PVC PIPEVENT OR (E)' METING � MAP � : -THE CAPACITY OF STANDALONE SYSTEM SUPPLY SHALL'BE EQUAL TO - - u^ £� GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION nwnwcuE Roa NY axo ESS ENERGY STORAGE SYSTEM : ® " METAL PIPE VENT'; VICINITY' .� rA%M R5e30a5�T aOgp .YrESTWm' . EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A) Ex EXTERIOR ALUPASS THROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8 :: ®' .T-VENT ter. :.''i CUSTOMER RESIDENCE: INT INTERIOR _ - SATELLITE DISH :. FREDERICK HERBST: MSP MI1W SERVICE PANEL _ ,: _ ": .; �•�• 1105 WESTWOOD LN, (N) NEW ® FIRE SETBACKS. .: .di '• R .1 .. .. _u �� ... .. ... .. .. �. c:':...• NTS:-:. NOT TO SOALE .. •. '. •. .. :. OC:. ON CENTER: :. :: :'.• HARDSCAPE .. .: . . .<" '.o TEL.646)26D0.9163Y'1 944 '`• ' " "t,•' ?'' APN:1000;033-00-02-00-005.060 :.: PaE-FAe: PRE-FAeaICArEo : —PL- PROPERTY'LINE PROJECT NUMBER: PSF,; POUNDS PER SQUARE FOOT 216R-105HERB (-� INTERIOR EQUIPMENT. ; W. . . PHOTOVOLTAIC SHOWN AS DASHEDs. L J f DESIGNER: ..(415)560-6920 ex3 " RSD RAPOSHUTDOWN DEVICE .. .. , SOLAR MODULES.. .. ':. .. .. .. . °s: DANIEL MARQUEZ TL TRANSFORMERLESS " " .. .. . .. .. 'y scALe::NTs � " SHEET TYP TYPICAL. REV. :. NAME DATE COMMENTS COVER SHEET v vods :.� .. _ B1: : ^'k: . LEE 31424 ESS REDLINE W WATTS SNR MOUNT s' , o-.c^"�' REV:B 3/42024 LANDSCAPE' .. .. .. ... .. W.. .. .. .. .. .. SNR MOUNT BSKIRT � : � � _ : PAGE w__. PORTRAIT: :. .. � .. .. amplafe vers1an_0,0.9 . .. . . . .. SITE PLAN-SCALE=0'-0 3/64"=V-0" . . ' .VBP BtTMP FIRE SETBACKS .v� �•. /��" A AC fJ LI P� L '(E):SKYGHT. (E)SKYLIGHT (N)ARRAY AR-03 � i ROOF PATHWAYS — f m. (3'TYP) - :at. . (E) .. . RESIDENCE . 3cFsZtm_Wirtda .. .. .. .. 1 w. .. w. NEW (E)POOL " — — ���/// NOTES:=ES5,SHALL_BEINST41LL'ED:3FT m 2� I FRO DOORS AND WINDOWS IW. - Ci .. n . _CORDM:� A C 095450 2 . .�1ANCE:WITH-R327: RpFESSlONP '.. (N)ARP A AR-0 2.. (N)ARRAY AR- 1 . ':ROOF PATHWAYS :. ': f (E)DRIVEWAY (3 T.YP) (E)SKYUGHT 00825-ME .: .. a.: d:.' 1n fJ41TNG11E RJIX ROFD,WESIBIIRY .. ... .. ... .. .. ... .. ... ... ... GHOlp=8055W 5C0] ... ... .. .. .: CUSTOMER RESIDENCE' SE FREDERICK HERBST: "•_a� ,1'!05 WESTWOOD'' . GREENPORT,NY;11944 :. 'i .. .. . '.. .. � TEL.sa so- 9163 B APN:10oa633-00 o2-oaoos000 ' PROJECT NUMBER: NOTES: 216R-105HERB - ..RESIDENCE DOES NOT CONTAIN ACTIVE FIRE: .r SPRINKLERS. v W DESIGNER: o ss2o i OOO LN ARRAY DETAILS: :: :. '' :: :. '. ': . . •" :ARRAY TRUE•PV AREA IELMAR U Z.' • TOTAL ROOF SURFACE AREA:3064 SQFT.; - - PITCH AZIM :(SQFT) SHEET ' • TOTAL PV ARRAY AREA:591.8 SQ FT. .. :. :. - :. m. SITE PLAN PERCENTAGE PV COVERAGE: AR:01 27° 256 359.3 (TOTAL PV ARRAY AREA/FOTAL ROOF SURFACE m a - - AR-02 40° 256°' 105.7 1 REV:B 3/4/2024 . '.:AREA)°100=19.3% rw _- ' AR-03 10°.- 256° 126.8"- PAGE ate verslon_4 09 .. :. ROOF INFO '. :. '. :. FRAMING INFO '. :. ATTACHMENT INFORMATION - DESIGN CRITERIA' Detail Configuration OC Max Landscape Mai Landscape Maz PorVait Max Port(ait Name Type Heigh MAX DISTRIBUTED LOAD:'3 PSF ..t T ype .. . .Max Span Spacing OC Spacing. Overhang OC Spacing. .Overhang SNOW LOAD:25 PSF WINDSPEED­ AR-01 ;COMP SHINGLE:RLU 2-Story: 2X8;RAFTERS 15'-9" 15" RL UNIVERSAL,SPEEDSEAL TRACK ON*•; 5'-4 2'-1" 4'-0"; - 2'-0" STAGGERED 128 MPH 3 SEC GUST. .. ., COMP•,:SEE DETAIL•SNR-DC-00436. S.S:LAG SCREW, • RL UNIVERSAL,SPEEDSEAL TRACK ON. ': - - 5/16'::2.5"MIN.EMBEDMENT AR-02 ' COMPSHINGLE-RLU' 1-Story' :. 2XB-RAFTERS 14'-11" 16" COMP,SEE DETAIL SNR-DC-00436 5'-'4" 2'-1" 4'-0" 2'-0" STAGGERED AR- COMP SHINGLE-RLU . 1-Story 2X10 RAFTERS 16'-.7". 24": 6'-0" 2'-4" NA NA STAGGERED RL UNIVERSAL,SPEEDSEAL TRACK ON _ ... :. COMP,SEE DETAIL SNR=DC-00436 :: .. :: ... :. .. .. D1=AR-01-SCALE:'1/8"=V-0" :. 1 D2-AR-02-SCALE:0:015625 ' AZIM:256° REQUIRED AZJM:256" — — - PITCH:27° = - ' UNDERIPVAR PITCH:40° ——————————— .-"V.3 ---� }. -3,�,.; 18,:B„• 2,5„1 _B,_7,.— .. .16,_8„ —6'-4':--6,_Z 3',11" - �. 3I '4�OF EwyO Jy Iy 54 .. .. .1 .. .. .. ... .. ; . .. .. — _ .. .. y'CQ'�Sy KAN,iq.. :: :. I .. .. .. .. O I: :.I' Q ,.T;P x �R ..Ea _5„ 0 .. ..095450 43, 5 A ROFESSI I: J I.94' :I .. .. " 5,10„ I. .. .. .. .. .. .. • _6,_2"— —T-1" 4,_7„ I .: f q. '... . . .:: sunrun . (E)'SKYLIGHT . . D3.-AR-03-SCALE:1/8"=1'-0" 00825-ME .: AZI M:256°. W 11.. .. .. .. .. .. .. ncnrurwcue rmac aonovesreuar .. -•. iPN rvE 965 PITCH:10°_" " -{V-6 18_8 — 1'-11" Faiea W82=se w. OIIST.OMER RESIDENCE.' IN R STALLERS SHALL NOTIFY ENGINEER OF ANY:" RED RI HERBST .:POTENTIAL STRUCTURAL ISSUES OBSERVED- .' 1'105 WESTWOOD_LN, PRIOR TO PROCEEDING W/INSTALLATION G EENPORT NY'11944 944 : :. O _ •" 10' - ,� •IF ARRAY(EXCLUDING:SKIRT)IS WITHIN:12" E SKY.CIGHT: ;. .(E)SKYLIGHT _ BOUNDARY REGION OF ANY ROOF PLANE - tir,•9 R. EDGES(EXCEPT VALLEYS),THEN �� �� APN:1000-033-,00-02-00-005-000 ATTACHMENTS NEED TO ADDED " PROJECT NUMBER: OVERHANG REDUCED WITHIN THE 12" 216R-i05HER6 BOUNDARY REGION ONLY:AS FOLLOWS: - ALLOWABLE ATTACHMENT SPACING DESIGNER' (415)5 ex? 6'-11 INDICATED ON PLANS TO BE REDUCED BY 50%. . . " —6'TYP- ••.ALLOWABLE OVERHANG INDICATED ON DANIEL MAROUEZ.': • I ..ATTACHMENT SPACING I ON P LAYOUT PLANS TO BE 1/5TH OF ALLOWABLE SHEET AT MENT SPAC INDICATED PLANS. .. .. .. .. REV:B 3/4/2024 AG PV30q. .. Te�la(e versi°n_4"095 . .. .. .. TABLE 1:ACCEPTABLE MIN.LUMBER TYPE NOTES: . . . . . . . . . LUMBER SPECIES&GRADE MIN:Fb(psi) 1.'INSTALLATION CREW TO LOCATE BROKEN MEMSERS.DURING INSTALLAND REPAIR AS SPECIFIED. ., DOUG FIR-LARCH#2 900 2.:RE ALIGN BROKEN MEMBER BACK TO ORIGINAL:ORIENTATION BEFORE)NSTALLING:SIMPSON A35 RAFTER HANGERS.. 3. INSTALL SIMPSON A35 RAFTER HANGERS ON BROKEN MEMBERS ON EACH SIDE OF RIDGE USING MANUFACTURER REQUIRED FASTENERS AND SPECIFICATIONS. SOUTHERN.PINE#1 1500. 4.•PROVIDE(N)"B"SISTERED RAFTERS TO(E)RAFTER;SEE DETAILS. ;. HEM-FIR#2 :. 850 . . . . . SPRUCE'PINE FIR#2 875 (N)SIMPSON A35 FROM SISTERED RAFTER TO RIDGE BEAM,SEE' TABLE 2:ACCEPTABLE ATTACHMENT SCHEDULE " BROKEN RAFTER. BLE TA 2'FOR CONNECTION REQUIREMENTS. : a FIELD MEMBER TYPE SPACING #ATEND w. " .:. Simpson Strong DriveO .. 2X:SCREWS , 8 12"OC� 6 . .. .. DW EWP-PLY.Screw .. :. PPsj.ENa OF B \` A35:NAILS COMMON 80ddttiru 16d• 6' C NA 12 TOTAL Damaged member .. .. 0 1 A35:SCREWS SIMPSON SD9112. T. NA 12.TOTAL TABLE 3::UPGRADE SPECIFICATIONS CALLOUT. VARIABLE . FTR SIZE P .• . -,; •For�2-Py 8istedrng Use Model#SDW22338 wa ,. _ . .. .... .. .. .. • �i F g Use 500 ATTACHMENT TYPE PER �• ' .: TABLE 2 SCHEDULE.' :� .: .. •or 3- istenn At Splice op ore Model • .,•'� (N)"B".EArra. ._SIDE RAFTER w: or P sun run 4 -_ =- -------- _ ME wi.. .:END CONDITION(TYP.)PER: .. .. .. ., TABLE 2 SCHEDULE �• .:I, CUSTOMER RESID��NCE: FREDERICK HERBST. (E)CEILING JOIST (N)SIMPSON A35 FROM'SISTERED ADD(N)"B"MEMBER 1 Ib5 WESTWOQD_LN, • ' ' ' RAFTER TO RIDGE BEAM,BOTH SEE SCHEDULE FOR OF EW YO R 1 944 '.:. .. .. (E)BEARING WALL TYPE"SIDES ATTACHMENT AND: h���E�.�N�q .�. � '' TEL.(646)280-8163 ' LUMBER E *.� 9+ �': ApN:1d6o-b33=6o-oz oo-ods-obo r = PROJECT NUMBER: 216R-105 SIDE VIEW ' RB(415)580-6920 ex3 DESIGNER: .. y NPR DDANIEL MARQUEZ. . ... ... 09545 w. DRAFTER REPAIR ELEVATION SHEET SCALE:NTs .SECTION REPAIR DETAIL . B scAGE;NTs REV.8 9I4I2024 OTES::$EE SECTION A FOR PAGE — .ATTACHMENT NOTES ., .. PV 3 1 .. .. 120240 VAC .. .. .. .. .. .. .,. .. .. SINGLE PHASE. .. .. .. .. .. .. .. .. .. ..SERVICE .. .. .. .. .. .. .. .. .. .. .. METER* .. .. PSEGLI 51778469 � 1 UTILITY. ACCOUNT 096760803m (N)200A BACKUP CTR . GATEWAY - Q2 .. .. .. .. .. GRID .. -. .. .. ... ... ..:611SITECURRENT ... .. ... .. .. .. ... .. .. .. ..NEURIO TRANSFow4ERs .. .. .. - . :. METER .. NEW200A .: :. .. .. .. :: :. .. .. MAIN {- BREAKER (N)30A E$S .. 2 .: _ .. .. 1 (END FED) BREAKER AT 'q CTR TESLA POWERWALL 2,13.5 KVM,6KW. . - NEW 225A .• OPPOSITE END L.Ill)ENERGY.STORAGE SYSTEMOF BUSBAR ��� `� _ 240V NOMINAL AC VOLTAGE, r►I MAIN L NEW (E)FACILITY�� PANEL:. .. - T 24A MAX AC CURRENT,NEMA 3R ,, ,, A��O,' Ery,.O LOADS :(N)AOA T' . — — 225A PV,BREAKERAT 1 .. .. .. .• �� pR.HOU Q� :: :• •: : MAIN BUS OPPOSITE END �� S� l OF BUSBAR (1)SOLAR PV CURREM r� TRANSFORMER 1 • TECHNOLOGIES: s.�u,.- •6 MAIN BR , . INTERNAL NT E NA ARDV AC DISCONNECT ECT 760 TYPE 0 WATT INVERTER 'JUNCTION box ' ' ' PV MODULES' — I I (N)IODA ` M EAKER . .. 3 3 7 HANWHA,Q CE DUO BLK (N)7OA GATEWAY _ ' FEEDER BREAKER �`. BACKUP oho _ !! 28 M10DULES OB�3S AT OPPOSITE END /_-- LOADS_PANEL - - - OPTIMIZERS WIRED IN: p/P OF BU8BAR: (E)RELOCATED BACKUP LOADS 1 SERIES OF 14 OPTIMIZERS B QFESSIONP SQUARE D LOAD RATED DC DISCONNECT (1)SERIES OF(14)OPTIMIZERS. NOTE: GENERATION BACKFEED=70A USED , FORIMERCONNECTION CALCULATIONS .DU222RB WITH AFCI,RAPID SHUTDOWN .. SOLAREDGEPOWEROPTIMIZERS: - 3R,60A.2P :COMPLIANT 5440 . . .. .. .. .. .. .. .. 120240VAC, , .. . . . . . . . . . . . . . . . . . . . . . . . . . r sup un . CONDUIT SCHEDULE. .. .. .. .. .. '.. # CONDUIT CONDUCTOR: NEUTRAL: : •GROUND ' NONE :(4)10AWGPVWRE:. 'NONE. (1).6 AWG BARE COPPER 82S .2 VF.VC OR EQUIV. .'(4)10 AWG THHN/THWN-2 NONE' (1).10AWG.THHN/THPM-2. 00 -ME .: .. 3. . .1"PVCOREQUIV. (2)8 AWG THHN/THWN-2 ,(1)10AWG THHN/II{WN-2 (1)8AWGTHHN/THWN-2 ,- .NVIu80 .. ... .. FNO�wsao sa CK ROAp.VrE5T6URY -' 4 T'PVC OR EQUIV.'-" (2)10 AWG THHN/THWN-2 (1)10AWG THHN/THWN-2 (1)8AWGTHHN/TH2 Fnz easxsa WN- zun al 5- 2"PVCOREQUIV.- (2)3 AWG.THHN/THWN-2 (1)8 AWG THHNnHWN-2 ,11)BAWG THHN?HWN-2 '- -' " " ' .. .. .. .. .. •• � CUSTOMER RESIDENCE- - 6 -VPVCOREQUIV. (2)4 AWG THHNrtHWN-2 -(I)B AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 •' FREDERICKHERBST- ' :. 1105 WESTWOOD'LN, , GREENPORT,NY,11944 MODULE CHARACTERISTICS - TEL.(646)280-9163 HANWHA O-CELLS:Q.PEAK DUO BLK S440.OPTIMIZERCHARACTERISTICS:.. p. .- HANWH+Q-CIE 405 W MIN INPUT VOLTAGE:.: 8 VDC APN:1000 033 UO-02-00-005 D00 OPEN CIRCUIT VOLTAGE: 45.34 V'MAX INPUT VOLTAGE:: 60 VDC ' PROJECT NUMBER' MAX POWER VOLTAGE: 45.34 V MAX INPUT ISC: 14.5 ADC 216R-105HERB SHORT CIRCUIT CURRENT: '11.17 A MAX OUTPUT CURRENT: 15 ADC ; .. .. .. .. .. 60692 . .. DESIGNER' (4I5)5 0 ex3 • �� � � DANIEL MAROUEZ ' SYSTEM CHARACTERISTICS-INVERTER b; SYSTEM SIZE: 11340 W _ SHEET SYSTEM OPEN CIRCUIT VOLTAGE: ':14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V ., .. .. MAX ALLOWABLE DC VOLTAGE: :480 V . REV:B � 34/2024 SYSTEM OPERATING CURRENT: 28.35 A - _ .. /1 SYSTEM SHORT CIRCUIT CURRENT: 30 A' PA GE Templefe v n 4095 INVERTERI NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL • 48 •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD 3 WORDS,COLORS AND SYMBOLS. DO NOT ADD LOADS •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN F THE CHARGE METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: MAX RA ••UTPUT CURRENT• •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF •OLUER••DC-TO-DC CONVERTER15 INVOLVED. LABEL LOCATION: APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LA E L LOCATION: N: DISCONNECT(S), PER CODE(S):NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION. SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. IN COMBINER PANEL(IF DISCONNECT(S), INVERTER(S),OC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2017:690.13(B) PER CODE(S):CEC 2019:690.53,NEC 2017:690.53 . WARNING . tCjf NEW y THREE POWER SUPPLY h'`P,`�Q HO(/ 0 pn="ERSOURCEOUTPUT SOURCES:UTILITY GRID, DO NOT RELOCATE THIS BATTERY AND PV SOLAR * _ OVERCURRENT DEVICE ELECTRIC SYSTEM C LABEL LOCATION: LABEL LOCATION: 41 ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. 108135 PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(B)(3), 705.12(B)(2)(3xb) 706.11(A),8 706.11(8) AR�FESSICII FOR • A■ PV SYSTEM LABEL LOCATION: INSTALLED WITHIN X OF RAPID SHUT DOWN s u n r u SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC 2012:W5.11.1,IFC 2018:1204.5.3 4- BUILDING SUPPLIED BY UTILITY GRID AND PHOTOVOLTAIC 00825-ME SOLAR PV SYSTEM EQUIPPED SYSTEM UN,w��EaoAonau�N.,,590 ■ WITH RAPID SHUTDOWN ` ' .� ■ CUSTOMER RESIDENCE: LABEL LOCATION: FREDERICK HERBST INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 1105 WESTWOOD LN, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. 3 GREENPORT,NY,11944 PER CODE(S):NEC 2017:690.31(G)(3),690.31(GX4), TURN RAPID SHUTDOWN IFC 2012:605.11.1.4 SWITCH TO THE"OFF' TEL(646)280-9163 POSITION TO SHUTDOWN APN:10DD-033-00-02-OD-005.OW PV SYSTEM AND REDUCE PROJECT NUMBER: PHOTOVOLTAIC ADISCONNECT SHOCK HAZARD IN THE 216R-105HERB MAXIMUM • ' 32 AMP ARRAY. DESIGNER: (a15)580 692D eX3 '• DANIEL MARQUEZ LABEL LOCATION'.OPERATINGNOMINAL • VOLTAGE PV SYSTEM DISCONNECT SHEETCURRENT LL �+ /'. AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. LABEL LOCATION: SI V NAGE PER CODE(S):CEC 2019:690.54,NEC 2017:690.54,NEC 2014:690.54,NEC ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE 2011:690.54 DISCONNECTING MEANS TO NMICH THE PV SYSTEMS ARE CONNECTED. LABEL LOCATION REV:B 1/4/2024 PER CODE(S):NEC 2017:690.56(C)(1 Na) POINT OF INTERCONNECTION PAGE (PER CODE:NEC690 56(B),NEC705.10,225.37,230.2(E)) PV-5.0 T•mp'Ne_ven !095 mad by dab DUO ctI�P.S•tlri' tt8r M Q CELLS � • i TOP BRAND PV JI •'�'�^�• Oryuly t•.e.e ti I C•"'" 2019 10.4W32587 Q.ANTUM TECHNOLOGY:LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area,lower BOS costs,higher power classes,and an efficiency rate of up to 19.9%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long term y eld security with Anti LID Technology,Anti PID 0 Technology,Hot-Spot Protect and Traceable Quality Tra.QT"t. EXTREME WEATHER RATING High-tech alum n-um alloy frame,cart fled for high snow(540013a)and wind loads(4000Pe). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performan::e warranty. t STATE OF THE ART MODULE TECHNOLOGY f _ Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. APT lest cond,bons according to 1EC/r S 62804-1:20I`,method a t-1500 V.168h1 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftreside pa rays onboldin Rooftop arrI as on nd residential bindings commercial and Ind7tdil bui dings Engineered in Germany OCELLS MECHANICAL SPECIFICATION ormat 66 3in x 39.4in x 1.26in(including frame) (1685mm x 1000mm x 32mm) - w+'aws•°.n :eight 41.21bs(18.7kg) - Front Cover 0.13in(32mm)thermally pre-stressed glass with ado ...+r rr°e..r •�r + ---anti-reflection technology -- oPo F.•. Beck Cover Composite film Frame Black anodized alkintinum Cell 6 x 20 m x ocryslalline O.ANTUM solar hell cats 'v,. Junction Box 2 09-3.98in x 1 26-2.36in x 0.59-0.71in � a4 w (53.101mm x 32.60mm x 15-18mm).IP67,with bypass diodes Cable - 4mme Solar cable;(+)-43.3in(1100mm),(-)>43.3in(1100 rrrm) ° +�.v w.oer..n s•tx.�r.xvw Connectot Stbubl MC4,Harwvhe Q CELLS HOC4,Amphenol UTX, Renhe 05-6,Tongling TL-CableDIS,JMTHY JM601.IP68 of tn•„r,n W..eu0 Friends PV2e;IP67 Te vs-t o x esa•u.sr..aj�_ ELECTRICAL CHARACTERISTICS POWER CLASS 315 320 325 330 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOL EPA NCE+5 W J-0 W) Power at MPP' P„. IWI '115 320 325 330 Short Circuit Current' It, (AI 999 10.04 10.10 30.15 Open Circuit Voltage' Vol- IV) 39.84 40.10 40.36 40.62 s_ Current at MPP 1� (A) 9.51 9.56 9.61 9.67 Voltage at MPP V„rr (VI 3314 33A7 33.81 34,14 Efficiency' q (%) z187 19.0 >49.3 z19.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT Power at MPP P t. IW) 235.9 239.6 2434 247.1 E Short Circuit Current Isc (A) 8.05 8.09 8.14 8.18 E Open Circuit Voltage Vs,,, IVI 37.56 3781 38.06 3831 c Current at MPP I,,,,o (AI 748 7.52 757 7.61 Vollag at MPP V_ IVI 31.53 31.85 32.17 3248 At8as. ,ner.r lnle..r.•s P„,t3%.I ,:5%et STC 1000Wfm2,25t2*C,AM1.5 according tolEC 60904.3•2800W/ml,NMOT,spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ^ WA&°.-'...u.a.r......� At Mast 98%of nominal � --�---power during , first year.Thereafter max.0.54% 3 • ........ . - degradation pet year At Mast 93.1% i; of nominal pourer up to 10 years At ' z " least 85%of nominal power up to s 25 years. ro _ • , Q All dale within rneasutemeni towtanc- a e➢ w es.Full warranties in accordance with rws eee ew es. sago Z e the warranty terms of the 0CELLS ,x,,.,,,,,;_, , sales organisation of your respective r w N country rc ,E. Typical module performance under low Irradiance c.W.tlonsin ' •°••""•"` "",0 ..�`•`..` comparison to STC conditions(25'C,1000W/mr) °° TEMPERATURE COEFFICIENTS 4004 Temperdiute Coafficlen(of Vw (; (%/KI -0.27 '•, Tomperalwu Coelhcient of P,,,, • 035 Te.^.-,ocr;,turo NMOT ('F) 309t5.4(A3t3'C) PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage V IVI 1000(IEC)/1000(UL) 111 p Maximum Series Fuse Rating IADCI 20 F if,Rating based on AN SO I UL 170 3 CPEC)/TYPE 2(UL) Max Dasigntoad,Push/Pull' Ibs/ft=) 75(3600Po)/55(2667Pa) Permitted Module Temperature -40'F Lip to+185°F a Ilbs/fig 113(5400P8)/84(4000Pa) on ocnnunusD!tty ( 40°Cupto+85° o ee Inslal at Ma at F QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION Ul!703.V0E C. 1 ly Tesled.CE-compliant,IEC 61215:2016,IEC$1730.2016, Number of Modvlos per Palot 32 Ag[-a--Cliff-''1,U.S Patent No 9893,215(solar cats) Number of Pallets per 53 Trader 30 C SPe Number of Patluts per 40'HC-Container_ 26 DVE cam, us Pallet Dimensions(LxWxH) 693x453-46 gin(1760-1150x1190mm) u Pallet Weight 141'-lbs(642kg) Noto:Installation nstnuctions must be followed.See the instal ahon and operating manual or contact out technical service department for further inf-nmer. n on approved ostallati,nand I$e of ibs product. Has of, O CELLS Aatarks Me. 400 Spectrum Center Drive,Sole 1400.Irvine,CA 92619.USA I lift#1 949 748 59 96 1 SIMML nquuy®us.q-cels.com I WO www.q•cels us solar=se • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US a solar-.: �a A solar[' IA �rJfr rte, i W2 2�1y'o �alBeJ�. f r 9 a 0 W e �, . � o 0 Optimized installation with HD-Wave technology - Specifically designed to work with power optimizers - Record-breaking efficiency - Fixed voltage inverter for longer strings - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 - UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small — High reliability without any electrolytic capacitors - Built-in module-level monitoring 1111111111119 I D — Outdoor and indoor installation wave — Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us So I a r ' • • ! Single Phase Inverter with HD Wave Technology for North America SE3000H-US/ SE380OH-US/ SE5000H-US / SE6000H-US/ SE760OH-US/ SE1000OH-US/ SE1140OH-US I SE3000H-USj SE380OH-US SESOOOH-US SE6000H-US SE760OH-US SE1000OH-US SE1140OH-US OUTPUT 3800 @ 240V _ 6000 @ 240V Rated AC Power Output 3000 5000 7600 10000 11400 VA .................. ...................... ... 3..... 208V 500 ......... 0 @.208V Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,�1a 208V. 5000@.208V. . AC Output Voltage Min:Nom:Max. ✓ ✓ Vat ...................... AC Output Voltage Min.-Nom:Max. ..Q11-240 264).......... ................! ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac ............. ................ ................. .............. ........... AC Fre uen Nominal 59.3-60-60.5ttt Hz .. C....9....�X(.....:...1...... _ Maximum Continuous Output Current 16 24 A 208V ...... ....... ....... ...... ........... Maximum Continuous Output Current � 9240V 12.5 16 21 25 32 42 47.5 A GFDIThreshold 1 A Utility Monitoring,Islanding Protection, ... Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 r 15500 17650 �W . xim I 00 Maximum DC Power @208V T5100 - 7750 ............. .. Transformer-less,Ungrounded Yes i Maximum Input Voltage 480 Vdc Maximum InputCurrent208V 9 80 400 Vdc Nominal DC Input Vo toe 3 ... Q.. ..... ..... ............... .......... 13.5 Maximum Input Current @240V 8.5 10.5 i 13.5 16.5 20 27 30.5 Adc ... ........... Max.Input Short Circuit Current 45 Adc _ .......... ................................. ......... ........... Reverse-PolarityProtection Yes Ground-Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 1 99 I 99.2 -. ....... CEC Wet.&ht .ed Efficiency 99 ...................... 5 Nighttime Power Consumption <2. I W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional'' Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) .................. _ _... �..... ..... Emissions FCC Part 15 Class B 1 INSTALLATION SPECIFICATIONS AC Output Conduit,Size/AWG Range 3/4"minimum/14-6AWG 3/4"minimum/14-4AWG P / g ... ............ 3/4"... .... g DC In ut Conduit Size k of Strip s/ 3/4"minimum/1-2 strings/14-6 AWG 3%4"minimum%1-3 strip s/ ............ . Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8/450 x 370 x 174 21.3 x 14.6 x 7.3%540 x 370 in/mm ..— .. ...... ........ ... ...... .... .... ... . ....... x185 Weight with Safety Switch 22/10 25 1/11.4 26.2/11.9 38.8/17.6 Ib/kg „Noise <25 I <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range I -13 to+140/-25 to+6013(40'F/-40'C option)'°' -F/-C Protection Rating NEMA 311(Inverter with Safety Switch) For other regional settings please contact SolarEdge support Ixi Revenue grade inverter P/N:SExxxxH-US000NNC2 1st For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na,pdf NI-40 version P/N:SExxxxH-US000NNU4 r,__——. c SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE Date:are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners. Snap rack- Solar Mounting Solutions RL Universal Installing Solar Has Never Been This Fast • Easif System designed with All parts fit in a box for easy maximum versatility for any logistics ` arrays including staggered Drop-in features make the � install process intuitive and fast __—__--_—__ Simple design allows system to be installed by single installer U Listed to UL Standard 2703 for on the roof � Groundin /Bondin and Fire g g Classification SnapNrack RL Universal highestis designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the • of N Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array \ • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments 41 I t� a Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing '► row-to-row bonding • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape module orientations '• Quality. Innovative . Superior. SnapNrack Solar Solutions are engineered to optimize material use and labor resources • improve overall installationquality and . • 2019 by SnapNrackSolar . DESCRIPTION: . . .DRAWN BY: . . . .. . .. A SNAP;NRCK, RL UNIVERSAL, MOUNT.;. .:. .:. mwatkins Shu, p. N�d :.: Solar Mounting:Solutions REVISION: PART NUMBER(S): 595 MARKS 94105 T STREET,29TH FLOOR•.SAN FRANCfSCO,CA USA PHONE(41 5)560-6900 a FAX(415)580-6902 242-021' 55 THE INFORMATION IN THIS ORANING IS OONRDENRALANO PROPRIETARY ANY REPROWOTON,OIS WURE,OR USE THERE0FjSPRO4iI9jWD NAl I9 WTHE' MI N LONSENTOFSUNRUN SOUTHLLO.. q. 10 5 .. 4. . . 9 7 8' .. 1. 2 0 ..... PARTS LIST ITEM. QTY :. DESGRI'PTION 1 1 , SNAPNRACK, RL.UNIVERSAL, RISER, MILL 2 .:'1 SNAPNRACK, RL UNIVERSAL, LEVELER. MILL ' 3. 1 SNAPNRACK, RL UNIVERSAL; MOUNT BOTTOM :MILL m. 4 1 SNAPNRACK, RL UNIVERSAL; MOUNT TOP, BLACK- . . 5 :1. . SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 . 1 SNAPNRACK, DROP IN/ROCK IN.CHANNEL NUT. .7 1 BOLT' FLANGE, 5/16IN-1$•X:3/4IN, CLEAR,.SS 8 1.. BOLT, FLANGE,.SERRATED, 5/16IN-1-8 X;1IN, SS 9 1 . SNAPNRACK, RL:UNIVERSAL, MOUNT.SPRING, SS 10. 1 BOLT, ELAN.GE, SERRATED,. 3/8IN-16 X 2-3%4IN, 1%2IN TRIM HEAD .1:2IN THREAD,:BLACK, SS MATERIALS: .. ... 60.00.SERIES'ALUMINUM.,.STAINLESS STEEL,.. OPTIONS: t DESIGN LOAD'(LBS)'. 623'UP; 674 DOWN, 505:SIDE ULTIMATE.LOAD LBS) : N/A TORQUE SPECIFICATION:': 12.LB,.FT. . : .CERTIFICATION`: : . : UL.2703, FILE E359313 WEIGHT (LBS): m0.73 DESCRIPTION: ''DRAWN BY: .. SNAFNRARS , MOUNT:.:,' .;. mwatkin ShOPNCK, RL UNIVEAL s . . . . REVISIO Solar Mounting:Solutions PART NUMBER(S): . :.: • - - S95 MARKET STREET;29TH FLOOR.'SAN FRANCISCO,CA 94105 USA :. ::. PHONE ) 6902 .. .. .. .. (815J 580.6900•FA%(415 5S0 242-02155.': . :' :.: :.: a. 111E I O-TIPON IN IL S DRE,OR U S CONREOF ISR AND ITED W TARY.ANY .. ... .. ... .. ... .. ... REPROWCTDN,MIRlENCONSRUSETHEREOFIS.PRDHISRED I.AZII9Uf T1E' ' ' - � � NRITTEN CONSENTOFSUNRUN SOUiN LIC. w. AI: :.: :. 1.50 2.35 ... . 1.50 : . .. 1.55 .. ' :66 . :.: . 1.24 • 100 :SLOT- a. sd :. 2;63 �-1.50 . ALL.DI'MENSIONS IN INCHES: "' ... .T .. ... .. .. ... .. .. ... .. .. .. .. .. ..: .. . . :: .. ': . :..: .: .: P .O V1/.:E R W A::L:.L 2 . A•C .::.. •: . :. : ..• . :' :• .: .. The Tesla:Powerwall.is a fully-integrated AC.battery'system for residential or light T: - SLn commercial use: Its:rechargeable lithium=ion battery pack provides energy storage for solar self-consumption;load shifting and backup power. . Powerwall's electrical interface provides a simple connection to anyhome or building. Its revolutionary compact design achieves:maeket-leading energy-density and is easy :: . .. :. ..:.. :. ..: . to install,:enabling owners to quickly realize the benefits of,reliable,clean.power.• PERFORMANCE SPECIFICATIONS -ENVIRONMENTAL-SPECIFICATIONS " AC Voltage(Nominal) :. ..: . '208 V,220 V,230 V 2.7.7.V, Operating.Temperature 20°C.to 50°C(-4°F to 122°F). .:- : .: 100/200 V,120/240 V...' Storage Temperature.: .. :�30°C to 60°C(-22°F to 140°F) Feed-In Type,- :,. Single•&Split=Phase - -- -- ---- - - - - - - -------- -- Operating Humidity.(RH). ': :' Up to 100%,condensing Grid Frequency 50 and 60 Hz - - -- - - 43 ft) axi Mmurn Altitude 3000 m(98 .... .. .... AC Energy':: ::: :13.2 kWh " . : : ______._.__-_______,_____._-__-____________.__ •____- .__- Environment . aridoorand.outdoor rated Real Power,max continuous 5 kW char a and discharge) z . :.. f ....9 r9 ) Enclosure Type . ... NEMA 313 Real Power,peak(10s)2 7 kW(discharge only) Ingress Rating IP67(Battery&Power'Electronics) Apparent Power,max continuous.-- 5.8 kVA(charge and discharge) IP56-(Wiring) . APPagent Power,peak f10s 2 7.2.kVA(d ischar a onlY) Noise Level @ 1 rn Imbalance for.Single-Plisse Loads 100%:: Power.Factor Output Range:. ..:.. +7-1.0 adjustable. .. FowerFacfor(full-rated.power)'- +/-0.85., ... .. MECHANICAL.SPECIFICATIONS. Depth of Discharge. . . 100yo . .' " ---" — " P _.. Dimensions 1150 mm x 755 mm x'155 mm Internal Battery DC Voltage: 50 V 145.3 in x 29.7 in x 6.1 in Round Trip Efficiency'.3 '89.0% Weight :122 kg(269 Ibs) Warranty ;.• 10 years:. . :.- : Mounting options . Floor or wall mount . Values.provided for2YC'(77°F),3.3 kw chargeldisch'arge power.... .. ,values:region-dependent. :. ' -AC tb batieiy,to AC,at beginning oiaife. " :. .. .. OMP•• " . C LIANCE I:N.FORMATION : .: ENERGY:GATEWAY SPECIFICATIONS --- ---- -------------------- - --- ---- --------- -- - -- -- ---- ---"-- Safety. _.:.. UL_1642,UL 1741,U L 1973;UL 9540; User Interface :; 50sla A ------- Pp UN38.3;1)_C62109-1,IEC.62619.,7. Connectivity . : . Wi-Fi,Ethernet;3G :. . : . CSA C22.2.107.1 - ------------- ------ ---- --- - - ..-....--- - - ------ ------ AC Meter Revenue grade Grid Standards Worldwide Compatibility Operating Modes : :Support for wide range,of.usage Emissions FCC-Part.15 Class B,ICES.003;--- scenarios :: E 6 000 Class.. , Backup Operation ;• Optional automatic disconnect. •" Environmental _ RoHS Directiv2:201.1/65/EU, switch-'.. WEEE Directive 2012/19/EU,... .. -- -- ---- --=----- —---- - - - _ - . • 2 06/66 Modularity :Supports up to 9 AC-coupled 0. E/,C• Powerwalls Seismic AC156,IEEE 693-2005(high) �..�..5 .6 ;; P'O W E R W.A L L..2 :.. :. . .. TYPICALSYSTEM . LAYQ.UT n r :. ..:.. SOLAR .. � . :. ..... : . INVERT .. E R' GRID - - . ----- METER ENERGY GATEWAY MAIN PANEL'' HOME AC POWERWALL T..=..S L ii : : :.P'O'W E'R W A L L..2 SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE 9 DESCRIPTION •SYSTEM SIZE:1134OW DC,760OW AC •ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE SE SERVICE ENTRANCE PV-1.0 COVER SHEET MODULES:(28. HANWHA Q-CELLS:Q.PEAK DUO BLK WITH 20181RC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS ) ML-G10*405 AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN MAIN PANEL •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH . MP PV-2.1 FLOOR PLAN SE760OH-USSN•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH PV-3.0 LAYOUT SP SUB-PANEL SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-3.1 REPAIR DETAIL GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. PV-4.0 j ELECTRICAL LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. PV-5.0 SIGNAGE •SUNRUN METER INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE 1,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ACAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC I •DC DISCONNECT(S) ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. Q •11.17 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •13.97 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. ABBREVIATIONS r—­1 INTERIOR EQUIPMENT A AMPERE L J SHOWN AS DASHED AD ALTERNATING CURRENT �O s u n r u n AFC ARC FAULT CIRCUIT INTERUPTER ® CHIMNEY ,`J COMP COMPOSITION l7� `DC DIRECT CURRENT Q ATTIC VENT r 00825-ME (E) EXISTING FLUSH ATTIC VENT VICINITY MAP U� RaA ESS ENERGY STORAGE SYSTEM 0 PVC PIPE VENT Fn GNrMOUEROAo_wES�UtY.NY I1590 EXT EXTERIOR ® METAL PIPE VENT ,.* CUSTOMER RESIDENCE: INT INTERIOR •w�® T-VENT FREDERICK HERBST N MSP MNSERVICE PANEL Z�fa L cj ✓. � WESTWOODLN, lNl NEW ,.P° -`4 ' IMENPORT,NY,11944 SATELLITE DISH % NTS NOT TO SCALE S ® TEL.(100 033-0 63 -0 OC ON CENTER FIRE SETBACKS ss P APN:1000-033-00-02-00-0OS-000 PREFAB PREFABRICATED __ PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT I_ HARDSCAPE • 216R-105HERB PV PHOTOVOLTAIC '-"J ••^ b,I DESIGNER: (415)580E920 ex3 RSD RAPID SHUTDO DEVICE PL— PROPERTY LINE .• a M SOLAR MODULES •• TL TRANSFORAERLESS `; DANIEL MARQUEZ LE:NTS SHEET TVP TVPxu - REV NAME DATE COMMENTS COVER SHEET V VOLTS w WATTS ++`ti µ.`� B D MARQUEZ 1 110 3/2 0 2 4 PW TO PV ONLY SNR MOUNT - 4 REV:Bi 3/11/2024 LAN LANDSCAPE SNR MOUNT 8 SKIRT PAGE PV-1.0 FOR PORTRAI T T--V"*wibn_.A.95 SITE PLAN-SCALE=3/64"=V-0" MP ® AC O FIRE SETBACKS INV SE (18"TYP) (E)SKYLIGHT (E)SKYLIGHT PL a. (N)ARRAY AR-03 ROOF PATHWAYS 1ti (3-TYP) � f (E)RESIDENCE (N)ARRAY AR-01 g (E)POOL IN)ARRAY AR-02 sunrun ROOF PATHWAYS (E)DRIVEWAY (3'TYP) (E)SKYLIGHT 00825-ME � 1]]CAMIAOUE ROCK ROAD.WESTBURV.NV 1t5G0 RHONE OOS.S�O.SH] M63M.]0]] CUSTOMER RESIDENCE: FREDERICK HERBST 1105 WESTWOOD LN, GREENPORT,NY,11944 ARRAY TRUE PV AREA PITCH AZIM (SOFT) TEL,(646)280-9163 p1, AR-01 27° 256° 359.3 APN:1000-033-00-02-00-005-000 NOTES: �'`N PROJECT 5HERBER: AR-02 40° 256° 105.7 • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE g 000 AR-03 10° 256° 126.8 SPRINKLERS. ' WE T DESIGNER: (415)580-6920 ex3 ARRAY DETAILS: ' DANIEL MARQUEZ • TOTAL ROOF SURFACE AREA:3064 SOFT. v� SHEET • TOTAL PV ARRAY AREA:591.8 SO FT. SITE PLAN • PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE REV:Bi 3/11/2024 AREA)'100=19.3% PAGE PV-2.0 7r]pl te_Rs]+�OR_4.0.95 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max Span OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PS Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 15'-9" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4' 2'-l' 4'-0' 2'-0" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 14'-11" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4' 2'-1" 4--0- 2'-0" STAGGERED 5116":2.5"MIN.EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 16'-7' 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" NA NA STAGGERED ��^� COMP,SEE DETAIL SNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" / , \ D2- :256 -SCALE:3/16"=1'-0" AZIM:256° J SISTERING REQUIRED AZIM:256° —�-3— UNDER PV ARRAY {-3'4'— 18'-8' 2'-5'{- PITCH:27' —————————— PITCH:40° I I_ pL� � -5�'TYP— 3,IV0"I I � ❑ I I I I 6'-11" 13'-5" 10'-5"1 II I 1 - 5'-4'TYP 1 I - I 1 5'-101 I I I I I I s'-7' 1 —6'-2"——6'4"— —6'-2"—1-6" 1 ——————————————————————————————— -- (E)SKYLIGHT J i - sunrun D3-AR-03-SCALE:1/8"=1'-0" 00825 ME ADM:256° 1—UE— ,WE—URY,xY115K PNcwiaei PITCH:10° -{3'-0" 18'-8" — 1'-11" F INSTALLERS SHALL NOTIFY ENGINEER OF ANY CUSTOMER RESIDENCE: POTENTIAL STRUCTURAL ISSUES OBSERVED FREDERICK HERBST PRIOR TO PROCEEDING W/INSTALLATION. 1105 WESTWOOD LN, IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" GREENPORT,NY,11944 10' BOUNDARY REGION OF ANY ROOF PLANE (E)SKYLIGHT (E)SKYLIGHT EDGES(EXCEPT VALLEYS),THEN TEL.(646)280-9163 ATTACHMENTS NEED TO BE ADDED AND APN:1000-033400.02-00-005-000 r9" OVERHANG REDUCED WITHIN THE 12" PROJECT NUMBER: BOUNDARY REGION ONLY AS FOLLOWS: 216R-105HERB "ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. DESIGNER: (415)580-6920 ex3 6'-11' •`ALLOWABLE OVERHANG INDICATED ON DANIEL MARQUEZ —6'TYP— I PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. SHEET LAYOUT 11"� REV:B1 3/11/2024 PAGE PV-3.0 T-*W._5wwn_4.0.85 TABLE 1:ACCEPTABLE MIN.LUMBER TYPE NOTES: LUMBER SPECIES&GRADE MIN.Fb(psi) 1. INSTALLATION CREW TO LOCATE BROKEN MEMBERS DURING INSTALL AND REPAIR AS SPECIFIED. DOUG FIR-LARCH#2 900 2. RE-ALIGN BROKEN MEMBER BACK TO ORIGINAL ORIENTATION BEFORE INSTALLING SIMPSON A35 RAFTER HANGERS. 3. INSTALL SIMPSON A35 RAFTER HANGERS ON BROKEN MEMBERS ON EACH SIDE OF RIDGE USING MANUFACTURER REQUIRED FASTENERS AND SPECIFICATIONS. SOUTHERN PINE#1 1500 4. PROVIDE(N)'B"SISTERED RAFTERS TO(E)RAFTER,SEE DETAILS. HEM-FIR#2 850 (N)SIMPSON A35 FROM SISTERED SPRUCE PINE FIR#2 875 RAFTER TO RIDGE BEAM,SEE TABLE 2:ACCEPTABLE ATTACHMENT SCHEDULE BROKEN RAFTER TABLE 2 FOR CONNECTION REQUIREMENTS. FIELD MEMBER TYPE SPACING #AT END "A" 2X:SCREWS Simpson Strong-Drive® 12'OC 6 SDW EWP-PLY Screw` b;7Z ,\ uM S\S.�ER Z � O , NAILS COMMON 0d thr t6d' 6C 1 2 TOTAL Damaged member ?PIS, NA A35:SCREWS SIMPSON SD9112 NA 12 TOTAL �ENGIN_ ' TABLE 3: UPGRADE SPECIFICATIONS CALLOUT VARIABLE SIZE RAFTER SIZE"8•• 2x8 r w'�' • • • / ` 'For 2-1y Sistenng Use Model#SDW22338 r` • i • {\ 'For 3-ft Sistenng(At Splice Locetbns)Use Model#SDW22500 ATTACHMENT TYPE PER ��� • `\ TABLE 2 SCHEDULE i ( • • • (N)"B"EA.SIDE RAFTER I\ • • / . � NP sunrun --- r--------� 00825-ME i i END CONDITION TYP. �„eb PERE .•w.sb, I TABLE 2 SCHEDULE ....umernz L CUSTOMER RESIDENCE: I FREDERICK HERBST I I (E)CEILING JOIST (N)SIMPSON A35 FROM SISTERED ADD(N)'B'MEMBER 1105 WESTWOOD LN, L� RAFTER TO RIDGE BEAM,BOTH SEE SCHEDULE FOR GREENPORT,NY,11944 (E)BEARING WALL SIDES. ATTACHMENT AND TEL.(646)280-9163 LUMBER TYPE APN:1000-033-00-02-00-005-000 PROJECT NUMBER: 216R-105HERB A SIDE VIEW DESIGNER: (415)580-6920 ex3 DANIEL MARQUEZ RAFTER REPAIR ELEVATION SHEET REPAIR DETAIL SCALE:NTS SECTION B SCALE:NTS REV:81 3/11/2024 NOTES: SEE SECTION A FOR PAGE ATTACHMENT NOTES PV-3.1 :120/240 VAC:.. SINGLE PHASE .. SERVICE:: .. .. . METER _M PSEGLI61778469 UTILITY O.: ACCOUNT#9676080303' GRID NOTE:TOTAL PV 13ACKFEED`40A ..... .: INUSED FOR TERCONNECTION':'-': EXISTING CALCULATIONS r 200A MAIN .. TIO NSR . BREAKER ... ... ... ... EXISTING ..... : ..... .: 200A' (N)LOCKABLE SOLAREDGE TECHNOLOGIES: MAIN : . 7600 WATTSSV BLADE TYPE FACILITY �: :..� PANEL-..' At DISCONNECT: .: INVERTER: .: JUNCTION BOX: FV MODULES LOADS 200 A :MAIN BUS ... .. ..• ... 2 ... O Q 1 HANWHA. -CELLS:.Q.PEAK DUO BLK.- �� . ... .. /j ML-G10+.05 o�� ( / (28)MODULES 7 - - OPTIMIZERS WIRED IN:" :.. S .. .. FACILITY: : .. .. .. ... ... ... (1)SERIES OF(14).OPTIMIZER (N)�40A GROUND 3 SQUARED 13. LOAD'RATED DC DISCONNECT" (1)SERIES OF(14)OPTIMIZERS' PV BREAKER AT DU222RR§_ WITH AFCI;RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,: COMPLIANT' S440.' .. OF BUSBAR 120/24019AC CONDUIT SCHEDULE: - m-- sunr n ... ... ... ..... .: ' :9. CONDUIT... .:-.CONDUCTOR ':':'." NEUTRAL' GROUND: 1 NONE' (4)10 AWG PV WIRE NONE:' (1)10AWG BARE COPPER .. .. .. .. .. .. .. .. 2. 3/4'EMT:OREOUIV. (4)_10 AWG THHN/THWN-2 :NONE' :(1)10AWG THHN(THWN-2 ... : B .00 25-ME ' 3 3/4'EMT OR EOUN. (2)8AWG THHN/iliWN-2- � �� � �••• (1)10 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 - ..-- . FA%M528020n CUSTOMER RESIDENCE: • - FREDERICKHERBST .. .. ... ... .. ... ... .. ... 1705 WESTW004 LN, . .. - - .. .. GREENPORT;NY,11944 MODULE CHARACTERISTICS;• TEL.(sas)zeo g163 5440 OPTIMIZER CHARACTERISTICS:" HANWHA Q-CELLS;Q.PEAK DUO BLK MIN INPUT VOLTAGE:: 8 VDC APN:1000-033-00-02-00-005-000.. ML'-G10+405:' 405 W MAX INPUT VOLTAGE: 60.VDC PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 45.34 V; INPUT ISC; :,. 14,5 ADC, 216R-105HERB "MAX POWER VOLTAGE: "' .:37.39 V:MAX OUTPUT CURRENT: 15 ADO " SHORT CIRCUIT CURRENT: 11.17 A, 0�94 DESIGNER: - • SYSTEM CHARACTERISTICS-INVERTER 1 - • • . . . - . DANIEL MARQUEZ ' SYSTEM SIZE: :'11340 W.. .. .. � SHEET SYSTEM OPEN CIRCUIT VOLTAGE: -14 V :..- SYSTEM.OPERATING VOLTAGE: .400 V :.. ... ... ... .. . ELECTRICAL MAX ALLOWABLE DC VOLTAGE: '480 V '' - - ' SYSTEM OPERATING CURRENT.,. :: 28.35 A REV:61 3 024 SYSTEM SHORT CIRCUIT CURRENT: 30 A. .: ..... .: ..... .: PAGE... .PV . - _ _ Tarryilete renbn 1.0.95 INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL • 480 a •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD DO NOT ADD LOADS 30 •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN MAX RATED OUTPUT CURRENT OF THE CHARGE METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF •O a • • D 15 A INVOLVED. APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S):NEC 201T 705.12(Bx2x3xc) SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. G INVERTER(S),ADC DISCONNECT(S), LABEL LOCATION: •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):NEC 2017:690.13(B) PER CODE(S):CEC 2019:690.53.NEC 2017.690.53 EARNING THREE POWER SUPPLY �0! SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID, NOT RELOCATE THIS BATTERY AND PV SOLAR OVERCURRENT DEVICE ELECTRIC SYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(Bx3), 705.12(13)(2)(3)(b) 706.11(A),&706.11(B) FOR SOLAR LABEL LOCATION: s u n r u n INSTALLED WITHIN 3'OF RAPID BRUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC 2012:605.11.1,IFC 2018:1204.5.3 4„ _ BUILDING SUPPLIED BY UTILITY SOLAR PV SYSTEM EQUIPPED GRID AND PHOTOVOLTAIC 00825-ME • • • SYSTEM ,77�,wcuEno l—WEST9Unv r „— ` POWER • WITH RAPID SHUTDOWN °x ® CUSTOMER RESIDENCE: LABEL LOCATON: FREDERICK HERBST INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 1105 WESTWOOD LN, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, GREENPORT,NY,11944 ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. 3' TURN RAPID SHUTDOWN PER CODE(S):NEC 2017:690.31(Gx3),690.31(G)(4), TEE.(646)280-9163 IFC 201 2:605.11.1.4 SWITCH TO THE"OFF' POSITION TO SHUT DOWN APN:1000-033-00-02 00-005-000 PV SYSTEM AND REDUCE PROJECT NUMBER: PHOTOVOLTAIC AC DI • SHOCK HAZARD N THE 216R-105HERB MAXIMUM AC OPERATING CURRENT: 32 AMPS ARRAY. DESIGNER: (415)580-6920 ex3 NOMINAL OPERATING AC VOLTAGE: 240 VAC LL DANIEL MARQUEZ LABEL LOCATION: PV SYSTEM DISCONNECT SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. LABEL LOCATION: .SIG NAG E PER CODE(S):CEC 2019:690.54,NEC 2017:690.54,NEC 2014:690.54,NEC ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE 2011:690.54 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. LABEL LOCATION: REV:B1 3/11/2024 PER CODE(S):NEC 2017:690.56(Cx1xa) POINT OF INTERCONNECTION PAGE (PER CODE:NEC690.5WB),NEC705.10,225.37.2W.2(E)) PV-5.0 T-01l _•wtion_4.0.96 ... - ... ::,ENGINEERING CO . ::January:17,2024 . . . .. . :: AMEND ME CERTIFICATION LETTER . . . Project Address: ::: ::: " HERBST RESIDENCE 1105 WESTWOOD LA GREENPORT,:NY,11944 Design Criteria: =Applicable Codes=2020 NYSRC;:2018 IRC/IBC/IEBC,•ASCE 7-1.6 and 2018 NDS -Risk Category. II -Wind Speed 128 mph,Exposure Category B,Partially/Fully Enclosed Method : . Ground Snow Load=25.psf . ROOF AR-01 :2 x 8 @ 16"OG,Roof DL=8 psf,;Rdb'f LUSL=19 psf(Nori-PV);Roof LUSL=13.8 psf(PV) -ROOF AR-02:2 x 8 @ 16"OC,Roof DL=.8 psf,Roof LUSL=18 psf.(Nori-PV),Roof LL•(SL=9.7 psf(PV) -ROOF AR-03-:2 x 10 @ 24"OC,Roof:DL=.8 psf,Roof LUSL:=20:psf(Non-PV),Roof LUSL=20 psf(PV) To Whom It.May Concem, .A structural evaluation of loading was conducted for the above address based on the.design criteria listed above: Existing roof structural framing'has been.reviewed for additional loading due to installation'of"PV Solar System on the'roof..The structural review applies to the:sections of roof that is directly supporting the:solar PV system. .13ased on this evaluation,I,certify-that the alteration to.the existing structure by insfallatibn of the PV system.v✓ith.sistering under AR-01,: . . " :meets"the prescriptive compliance requirements of the:applicable existing building and/or new building provisions adopted/referenced above. ; .... . . . .... . . Additionally,the PV module assembly including attachment hardwaYe has been.reviewed to be in accordance with.the manufacturer's., specifications and to meet.and/or exceed the requirements set forth by the referenced codes. . . . :Sincerely, .. . . f NEW ig'i#alljr'signed • S�Q�,Y . .. by Humphrey. . . .• K . iu ' o95450 024 01 1 .... .. .... .. A .. 7 R0FE55 OAP 09:21:41 -05'00'. Mighty Engineering Co I1708 Roxbo rough:Rd Charlotte,NC 28211:I (980)689.9776 1 info@mightygngineeringco.com pglof9 I SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE:1134OW DC,7600W AC •ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE SE SERVICE ENTRANCE .PV-1.0 COVER SHEET MODULES:(28)HANWHA Q-CELLS:Q.PEAK DUO BLK WITH 2O18 IRC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS ML-G10+405 AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN MAIN PANEL •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH . MP PV-2.1 FLOOR PLAN SE760OH-USSN•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING VNLL COMPLY WITH PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY _,U NEW., PV-3.1 REPAIR DETAIL GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. cC y KAN,,q 0 PVA.O ELECTRICAL LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. r = PV-5.0 SIGNAGE •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. c5 w SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 095450 4� PM DEDICATED PV METER ARpPESSIONP� •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL Digitally signed CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1),AC AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). by Humphrey K •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. Ka rI U ICI QDC DISCONNECT(S) •11.17 AMPS MODULE SHORT CIRCUIT CURRENT. Date: 2024.05.30 CB IQ COMBINER BOX •13.97 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. 06:23:29 -04'00' ABBREVIATIONS F INTERIOR EQUIPMENT A AMPERE L_ SHOWN AS DASHED AC ALTERNATING CURRENT sunrun AFC ARC RC FAU FAULTCIRCURINTERUPTER ® CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT Q ATTIC VENT 00825-ME IE, I EXISTING 0 FLUSH ATTIC VENT VICINITY MAP ­ERo«RonD v.EsrBURr NY— ­NE ENERGY STORAGE SYSTEM G PVC PIPE VENT NONE500�' 1 � %81526620R EXT EXTERIOR 0 METAL PIPE VENT ♦ CUSTOMER RESIDENCE: INT INTERIOR �T'- • f FREDERICK HERBST MSP MAIN SERVICE PANEL ® T-VENT r,* a e• ♦' ` 1105 WESTWOOD LN, (N) NE. ,�° ' ;.•,' • GREENPORT,NY,11944 SATELLITE DISH NTS NOT TO SCALE • e• s TEL.(646)280-9163 OG ON CENTER ® FIRE SETBACKS �� s "d t -X d t APN:1000-033-00-02-00-005-000 PRE-FAB PRE-FABRICATED ,%A' -� PROJECT NUMBER: PST POUNDS PER SQUARE FOOT a HARDSCAPE ` a 216R-105HERB PV PHOTOVOLTAIC •^� DESIGNER: (415)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE PL— PROPERTY LINE r y , SOLAR MODULES ' c • DANEL MARQUEZ TL TRANSFORMERLESS SC LE:NTS t♦ / SHEET TYP TYPICAL i ♦v voLrs t REV NAME DATE COMMENTS COVER SHEET • ,WATTS B D MARQUEZ 11/03/2024 PW TO PV ONLY W NRMOUNT REV:61 3111/2 4 LAN LANDSCAPE k;NR MOUNT&SKIRT ` Y PAGE PV-1.0 POR PORTRAIT T—PI.I. n 4 0 95 SITE PLAN-SCALE=3/64"=V-0" MP ® AC FIRE SETBACKS INV AC SE (18"TYP) (E)SKYLIGHT (E)SKYLIGHT Pl (N)ARRAY AR-03 ROOF PATHWAYS PL (3-TYP) (E)RESIDENCE (N)ARRAY AR-01 OF IN INV (E)POOL r = � C1 W (N)ARRAY AR-02 20 095450 v RO�SSIONP sun run ROOF PATHWAYS (E)DRIVEWAY IT TYP) (E)SKYLIGHT '• 00825-ME • 177 MIX)E:7M RMD.NES-Y.NY 11W vHONE 005 SW 5b] nX B•5268 HfR • • • F CUSTOMER RESIDENCE: • FREDERICK HERBST 1105 WESTWOOD LN, •' GREENPORT,NY,11944 • ARRAY TRUE PV AREA PITCH AZIM (SOFT) TEL.(646)280-9163 AR-01 27° 256° 359.3 APN 1000-033-00-02-00-005-000 PROJECT ER: NOTES: r 2 6R 1 5HERB 256° 105.7 • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE g(Wp00 AR-02 40°AR-03 10° 256° 126.8 SPRINKLERS. DESIGNER: (415)580-6920 ex3 D ARRAY DETAILS: ANIEL MARQUEZ • TOTAL ROOF SURFACE AREA:3064 SQFT. P� SHEET • TOTAL PV ARRAY AREA:591.8 SO FT. SITE PLAN • PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE REV:B1 3/11/2024 AREA)'100=19.3% PAGE PV-2.0 Tempafe_vaisron a.0.95 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max Span OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PS Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 15'-9" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 14'-11" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 5/16":2-5"MIN.EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 16'-T' 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" NA NA STAGGERED COMP,SEE DETAIL SNR-DC-00436 D1-AR-01-SCALE:1/8"=V-0" 1 D2-AR-02-SCALE:3/16"=V-0" AZIM:256° SISTERING REQUIRED AZIM:256° PITCH:27' UNDER PV ARRAY PITCH:40° X 3'-4"— 18'-8" 2'-5" ------------------ ----- -----\ I I � 8'-7"— 18'-8" —6'A"— 6'-2"— 3'11" I I � I —5'-4"TYP— OF NEW 15,4„ 1 S �v KAIVj y0,Q� II ❑ I Q I 1 6'-11" * 7f 13,5" 10 5"I x II 1 m W TYP - I a I I 095450 a ?� I9,4„ I I pR0 SS10NP�� I I 5ID1 I I s'-7" I I --------------------------------- sunrun (E)SKYLIGHT 00826-ME D3-AR-03-SCALE:118"=V-0" AZIM:256° uE Roac rro�o.v.Es—Y Hr„sao vNONE 00551 2 PITCH:10° _yg'E„ 18'_8" — 1'_11„ F eszsepz:— 1 INSTALLERS SHALL NOTIFY ENGINEER OF ANY CUSTOMER RESIDENCE: �— POTENTIAL STRUCTURAL ISSUES OBSERVED FREDERICK HERBST PRIOR TO PROCEEDING W/INSTALLATION. 1105 WESTWOOD LN, 'IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" GREENPORT,NY,11944 10 BOUNDARY REGION OF ANY ROOF PLANE (E)SKYLIGHT (E)SKYLIGHT EDGES(EXCEPT VALLEYS),THEN TEL.(646)280-9163 ATTACHMENTS NEED TO BE ADDED AND APN:1000-033-00-02-00-005-000 �r 9" OVERHANG REDUCED WITHIN THE 12" PROJECT NUMBER: BOUNDARY REGION ONLY AS FOLLOWS: 216R-105HERB •'ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. DESIGNER: (415)580-6920 ex3 6'-11" "ALLOWABLE OVERHANG INDICATED ON DANIEL MARQUEZ —6'TYP— I PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. SHEET LAYOUT REV:B1 3/11/2024 PAGE PV-3.0 iampare ves�eo.9s TABLE 1:ACCEPTABLE MIN.LUMBER TYPE NOTES: LUMBER SPECIES&GRADE MIN.Fb(psi) 1. INSTALLATION CREW TO LOCATE BROKEN MEMBERS DURING INSTALL AND REPAIR AS SPECIFIED. DOUG FIR-LARCH#2 900 2. RE-ALIGN BROKEN MEMBER BACK TO ORIGINAL ORIENTATION BEFORE INSTALLING SIMPSON A35 RAFTER HANGERS. 3. INSTALL SIMPSON A35 RAFTER HANGERS ON BROKEN MEMBERS ON EACH SIDE OF RIDGE USING MANUFACTURER REQUIRED FASTENERS AND SPECIFICATIONS. SOUTHERN PINE#1 1500 4. PROVIDE(N)"B"SISTERED RAFTERS TO(E)RAFTER,SEE DETAILS. HEM-FIR#2 850 (N)SIMPSON A35 FROM SISTERED SPRUCE PINE FIR#2 875 RAFTER TO RIDGE BEAM,SEE TABLE 2:ACCEPTABLE ATTACHMENT SCHEDULE BROKEN RAFTER TABLE 2 FOR CONNECTION REQUIREMENTS. FIELD MEMBER TYPE SPACING #AT END "A" 2X:SCREWS Simpson Strong-Drive® 12"OC 6 SOW EWP-PLY Screw' O PPS ENO OF gREp,K B 2X NAIILS LS COMMON 180d thru 16d' 6'"OC 12 TOTAL i NA Uamayed member 2 I , A35:SCREWS SIMPSON SD9112 NA 12 TOTAL TABLE 3 UPGRADE SPECIFICATIONS CAL OUARIABLE RAFTER SIZE"Brr 2x8 .00, 'For 2-Ply Sistenng Use Model#SDN22338 i For 3-Ply Sistering(At Splice Locations)Use Model#SDW22500 ATTACHMENT TYPE PER TABLE 2 SCHEDULE � 1 (N)"B"EA.SIDE RAFTER I\ 3 / sunfu 1 i 1 r--------� 00825-ME END CONDITION TYP. PER -u+TwcuEeo«ea�os.eue..N.++sm ---------- -------------- `--------J ( ) v+gNE B055105b] I � TABLE 2 SCHEDULE `nx ws 2sa un / CUSTOMER RESIDENCE: FREDERICK HERBST I I (E)CEILING JOIST (N)SIMPSON A35 FROM SISTERED ADD(N)"B"MEMBER 1105 WESTWOOD LN, RAFTER TO RIDGE BEAM,BOTH SEE SCHEDULE FOR GREENPORT,NY,11944 (E)BEARING WALL SIDES. ATTACHMENT AND OF NE LUMBER LUMBER TYPE PqE YO TEL(100 033-0-0 o'� ��.( KANj,1 �Q� APN:1000-033-00-02-00-005-000 Q'r PROJECT NUMBER: * = C 216R-105HERB A SIDE VIEW of DESIGNER: (415)580-6920 ex3 DANIEL MARQUEZ 095450 t'� sHEE RAFTER REPAIR ELEVATION AR0 SSIONP� REPAIR DETAIL (D SCALE:NTS SECTION B SCALE:NTs EV:B1 3/11/2024 T SEE SECTION A FOR rR E ATTACHMENT NOTES PV-3.1 120/240 VAC SINGLE PHASE SERVICE O METER#: M PSEGLI51778469 UTILITY ACCOUNT#9676080303 GRID NOTE:TOTAL PV BACKFEED=40A I EXISTING USED FOR INTERCONNECTION C 1 200A MAIN CALCULATIONS BREAKER OF NEW y "p0. HOU EXISTING 2 200A (N)LOCKABLE SOLAREDGE TECHNOLOGIES: MAIN BLADE TYPE SE760OH-USSN — W FACILITY PANEL AC DISCONNECT 7600 WATT INVERTER JUNCTION BOX PV MODULES C LOADS 200 A OR EQUIVALENT ' 1 HANWHA Q-CELLS:Q.PEAK DUO ELK � 108135 MAIN BUS 2 ML-G10+405 SIONp� (28)MODULES `Y OPTIMIZERS WIRED IN: (1)SERIES OF(14)OPTIMIZERS (N)40A ca°ouw SQUARED LOAD RATED DC DISCONNECT (1)SERIES OF(14)OPTIMIZERS PV BREAKER AT DU222RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,60A,2P COMPLIANT S440 OF BUSBAR 120/240VAC CONDUIT SCHEDULE sunirun # CONDUIT CONDUCTOR NEUTRAL GROUND i NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 00825-ME 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHNITHWN-2 (1)8 AWG THHN/THWN-2 177 NTMGVE ROCKRWO.NESTBURr.NY1-1-22 ttYJO NONE B 6510 SCB] CUSTOMER RESIDENCE: FREDERICK HERBST 1105 WESTWOOD LN, GREENPORT,NY,11944 MODULE CHARACTERISTICS S44TEL.(646)280-9163 MIN I HANWHA Q-CELLS:Q.PEAK DUO BLK OPTIMIZER CHARACTERISTICS: APN:1000-033-00-02-00-005-000 ML-G10+405: 405 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 45.34 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX INPUT ISC: 14.5 ADC 216R-105HER8 MAX POWER VOLTAGE: 37.39 V SHORT CIRCUIT CURRENT. 11 17 A MAX OUTPUT CURRENT: 15 ADC 415 580-6920 ex3 DESIGNER: ( ) SYSTEM CHARACTERISTICS-INVERTER 1 DANIEL MARQUEZ SYSTEM SIZE: 11340 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 28,35 A REV Ell 3/11/2024: SYSTEM SHORT CIRCUIT CURRENT. 30 A PAGE PV-4.0 Tem0-versnn_4.0.95 INVERTER 1 NOTES AND SPECIFICATIONS: WARNING ARN tN •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL • 480 D •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD 30 WORDS,COLORS AND SYMBOLS. DO NOT ADD LOADS •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: .LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF CONTROLLER••D • INSTALLED ADC INVOLVED. APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2)(3)(c) SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), LABEL LOCATION: •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):NEC 2017:690.13(8) PER CODE(S):CEC 2019:690.53,NEC 2017.690.53 WARNING THREE POWER SUPPLY POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID, DO NOT RELOCATE THIS BATTERY AND PV SOLAR OVERCURRENT DEVICE ELECTRIC SYSTEM LABEL LOCATION: LABEL LOCATION: .c�OF NEI�,. ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN ` �f APPLICABLE). SERVICE PANEL. �~ytOR HOUC "�� PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(BX3), 705.12(Bx2x3)(b) 706.11(A),8706.11(B) * Z [1C Z ` 108135 c�?� � ,• A' O. SOLAR . SYSTEM ��FESSIONa� LABEL LOCATION'. INSTALLED WITHIN 3'OF RAPID SHUT DOWN SNITCH PER CODE(S):NEC 2017:690.56(CX3),IFC 2012:605.11.1,IFC 2019:1204.5.3 -- 4' BUILDING SUPPLIED BY UTILITY GRID AND PHOTOVOLTAIC 00825-ME SOLAR PV SYSTEM EQUIPPED SYSTEM • • • I>)GNTMGUE ROIX RWD.VESTaIRY.NY 1159� POWER WITH RAPID SHUTDOWN ® o -- F —�a� CUSTOMER RESIDENCE: LABEL LOCATION: FREDERICK HERBST INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 1105 WESTWOOD LN, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, GREENPORT,NY,11944 ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. TURN RAPID SHUTDOWN PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), IFC 2012:605A 1.1.4 SWITCH TO THE"OFF" .�o..E« TEL.(646)280-9163 POSITION TO SHUT DOWN APN:1000-033-00-02-00-005-D00 PV SYSTEM AND REDUCE PROJECT NUMBER: PHOTOVOLTAIC AC DISCONNECT SHOCK HAZARD IN THE 216R-105HER8 MAXIMUM AC OPERATING CURRENT: 32 AMPS ARRAY. DESIGNER: (415)580-6920 OX3 NOMINALLDANIEL MARQUEZ LABEL LOCATION: PV SYSTEM DISCONNECT SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. LABEL LOCATION: SIG NAG E PER CODE(S):CEC 2019:690.54,NEC 2017:690.54,NEC 2014:690.54,NEC ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE 2011:690.54 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. LABEL LOCATION. REV:Ell 3,1112024 PER CODE(S):NEC 2017:690.56(C)(1)(a) POINT OF INTERCONNECTION (PER CODE:NEC690 56(B),NEC705.10,225 37,230.2(E)) PAGE PV-5.0 Tempare_verswn�.0.95 OPEAK DUO BLK Im ML-G10+ SERIES ocells 390-410Wp 1132Cells 20.9% Maximum Module Efficiency MODEL O.PEAK DUO BLK ML-G10+/t �I Breaking the 20%efficiency barrier ;-TI I I I I� ��1 Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. A reliable investment Inclusive 25-year product warranty and 25-year linear war%�y performance warranty'. 0 Enduring high performance Long-term yield security with Anti LeTID Technology, «Mts Anti PID Technology'and Hot-Spot Protect Extreme weather rating High-tech aluminium alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). Innovative all-weather technology �J Optimal yields,whatever the weather with excellent low-light and temperature behaviour. The most thorough testing programme in the industry Qcells is the first solar module manufacturer to pass the most comprehensive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TOV Rheinland. =See data sheet on rear for further information, 'APT test conditions according to IEC/TS 62804.1:2015,method A(-1500V,96h) The ideal solution for: m+� .• "`°•. fan=NMM •nL2 Rooftop arrays on 34va p� »2_ 0 o residential buildings =^__�_• •••• :•�..° O PEAK DUO BLK ML-G10+ SERIES ■Mechanical Specification °nw3mm, Format 74.0in x 41.1 in x 1.26 in(including frame) aevwae mm, a pass , (1879mm x 1045mm x 32mm) Weight 48.51bs(22.0kg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass " 11-r 90- 18 15mm' „ m M'°83a mmi with anti-reflection technology er,asa mm, Back Cover Transparent composite film with black grid I paamN Frame Black anodlsed aluminium Cell 6 x 22 monocrystalline GANTUM solar half cells :npr as pmm Junction box 2.09-3.98 in x 1.26-2.36 in x 0.59-0.71 in (53401 mm x 32-60 mm x 15-18 mm),IP67 with bypass diodes °'Drell,. _ ..wum.ro ma ronasa + Cable 4 mm2 Solar cable;(+)t72.04 in 0830 mm),(-)272.04In(1830 mm) Connector Staubli MC4;IP68 'mml -aA ii-ra,,.,o 0.9SRAsa•,a I�Io"Asw,a ■Electrical Characteristics POWER CLASS 390 395 400 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STCI(POWER TOLERANCE+5 W/-0 W) BSTC' BSTC' BSTC" BSTC' BSTC' Power at MPP' P-P [1N] 390 426.6 395 432.1 400 437.5 405 443.0 410 448.5 E Short Circuit Current' IS, [A] 11.01 12.05 11.04 12.08 11.07 12.11 11.10 12.15 11.13 12JS E Open Circuit Voltage' Voc M 45.49 45.65 45.52 45.68 45.55 45.72 45.59 45.75 45.62 45.78 Current at MPP I_ [A] 10.39 11.37 10.45 11.43 10.50 11.49 10.56 11.55 10.61 11.61 Voltage at MPP V- M 37.54 37.53 37.81 37.81 38.09 38.08 38.36 38.35 38.63 38.62 Efficiency' n [%] 219.9 220.1 2:20.4 k20.6 220.9 Bifaciality of PN„and IS,70%t10%•Bifaciality given for rear side irradiation on top of STC(front side)•According to IEC 60904-1-2according to IEC 60904-3 'Measurement tolerances P.t 3%;Ix,Voc t 5%at STC:1000 W/m2;'at BSTC:1000 W/m=+(p x 135 W/m2,(p=70%t10%,25t 2°C,AM 1.5 according to IEC 60904-3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP Pap, CM 292.6 296.3 300.1 303.8 307.6 E Short Circuit Current Ix (A] 8.87 8.89 8.92 8.94 8.97 'cE Open Circuit Voltage Voc M 42.90 42.93 42.96 42.99 43.03 f Current at MPP 1„P, [A] 8.16 8.21 8.26 8.31 8.36 Voltage at MPP Vim, M 35.86 36JO 36.33 36.57 36.80 'Measurement tolerances PN,P 13%:Isc;Va t5%at STC:1000 W/m2,25t2'C.AM 1.5 according to IEC 60904-3•2800 W/m2,NMOT,spectrum AM 1.5 Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ho ae At least 98%of nominal power . during first year.Thereafter max. t; I o sa - ------------- 0.5%degradation per year.At A least 93.5%of nominal power LL - --,•-----y----- 9 up to 10 years.At least 86%of w ig nominal power up to 25 years. ? a Y All data within measurement w so ua w tolerances.Full warranties in aaccordance with the warranty sl g o ao terms of the Qcells sales ap 5 u 0 o os to 1s :0 21 organisation of your respective 200 40o aoo Soo loco YEARS country. IRRADIANCE IW/m'I o 4 i� 'standard terms of guarantee for the 5 Pv companies with the highest production capacity In 20211February 2021) Typical module performance under low irradiance condNons In -comparison to STC conditions(25'C,q00 W/m'). TEMPERATURE COEFFICIENTS Temperature Coefficient of Ise a [%/K] +0.04 Temperature Coefficient of Voc P [%/K] -0.27 �? Temperature Coefficient of PMPe y (%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109t5.4 (43t3'C) o ■Properties for System Design a Maximum System Voltage VsYs [V] 1000 QEC)/1000(Uu PV module classification Class II o Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 Max.Design Load,Push/Pulls [Ibs/ft2] 75(3600 Pa)/55(26601pa) Permitted Module Temperature -40'F up to+185'F Max.Test Load,Push/Pull' [Ibs/fN] 113(5400Pa)/84(4000Pa) on Continuous Duty (-40'C up to+85'C) 3 See Installation Manual at Qualifications and Certificates UL 61730,CE-compliant, Quality Controlled PV-TUV Rheinland, IEC 612ent No.,IEC 61730:2016, Ous U.S.Patent No.9.893,215(solar cellsl. C C/I c g o ,lmvr ❑e � ou Ocells pursues minimizing paper output in consideration of the global environment. Note'.Installation instructions mast be followed.Contact our techn,cal service for fuller information on approved Installation of this product. Q ce I I S Harlwha N a CELLS America Inc.400 spectrum Center Drive.Suite 1400.Imne,CA 92618.USA I TEL 949 748 59 961 EMAIL hQaimuiryf8acells.com I WEB www.gcells.com solar=ee • Single Phase Inverter with HD-Wave Technology • for North America SE3000H—US/SE380OH—US/SE5000H—US/ SE6000H—US/SE760OH—US/SE1000OH—US/SE1140OH—US j11r 0 solar�T • •�•,� Iwo.• � > • 2-25' Wartanh ti 0 e O dmA6.4W— O I, o e e � o 0 Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors W.M Built-in module-level monitoring IIIIIIIIIIII Outdoor and indoor installation wave Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us I solar=@ " Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US/ SE5000H-US/ SE6000H-US/ SE760OH-US/ SE10000H-US / SE1140OH-US SE30WH-US SE380OH-US I SE5000H-US SE6000H-US I SE760OH-US SE10000H-US SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ............................................. ............... 00.@.208V. ................ .500 33 0.�1°.208V................. ................ ................ ........... Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ...................................... ............... 3300.(&.208V, .. AC Output Voltage Min:Nom:Max. Vac .(183,-208„229).......................... . AC Output Voltage Min:Nom:Max. ✓...... .......✓...... .......✓....... .......✓...............✓...... .......✓....... .......✓....... ...Vac.... ..A4._240,-264).......................... .. ............. ............... ................................ ............... ................ ................ ........... AC Frequency(Nominal) 59.3-60-60.5i'i Hz ... ............... ............... ........................... ................ ................ ........... Maximum Continuous Output Current 208V 16 24 A ... ............... ............... ................................ ............... ................ . Maximum Continuous Output Current ............... ........... 240V 1 2.5 16 21 25 32 42 47.5 A GFDI Threshold 1 A .................................. .......................I......... Yes........................................................ ........... Utility Monitoring,Islanding Protection, Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 0300 11800 15500 17650 W ....... ............................. ......... .......... Maximum DC Power @208V 5100 7750 ....................................... .......... ............... ................................................ ................ ..... Transformer,Iess,Ungrounded .... - Yes 480....................................................... .. Vdc.... ........................................................... Nominal OC Input Voltage 380 400 Vdc ......... .. ............... ............... ............ f.. I.. n. ,Maximum.lnput Current @2 OV......... ......a:5...... .....10.5.....I......13:5..... ......16.5.............20......1.......?7.......1......30:5...... ...Adc.... Max.In ut Short Circuit Current 45 Adc P.. .............. ..............................................-...... ...................................................... .... Reverse:Polarity Protection Yes .............. ................................. ........................................................ ........... Ground-Fault Isolation Detection 600ko Sensitivity ...i..i . m................................. ......46. ........... . ................ ................ .... . ........................................................ Maximum Inverter Efficiency............. .. ...99..... ......._....._99.2 .__.% .................................. ............................................... ..... CEC Weighted Efficiency ...............99 ....%..... .................. .......................................... ....................................................... Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES 11m. .6 Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) ............ Revee Grade Data,?NMk 12;20........ ....... ............ ..... ......... ......... „Opttonallzi nu „ .................................................. ........... Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 ............................................. ............................................................ Grid Connection Standards IEEE1547,Rule 21,Rule 14 4H1� Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size./AWG Ran a 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size m/#of Strings/ 3 inimum%1-3 strings/ AWG R a 3/4"minimum/1-2 strings/14-6 AWG .........a..n.g ............................... .................................................................................. ...........M-A AWG........... ........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3 540 x 370 in/mm x 185 ............ ................................. ... Wei ht with Safe Switch 22 30 25.1 11.4 2 .2 1.6 1 9 38.8 17.6 Ib tY / / / Noise <25 <50 deA ............................................. ................................................................................................................... ........... Cooling.................................... ......................Natural Convection.......................................Natural convection Operating Temperature Range 13 to+140/-25 to+6dai(:40'F/ 40'C option)I'I 'F('C ........... .................................. Protection wnll NEMA 3R�1nverter with Safety Switch) Ill For other regional settings please contact SolarEdge support pi Revenue grade inverter P/N:SExxuH-U5000NNC2 isi For power de-raring information refer to:https://www.wlamdge.com/sites/default/files/se-temperature-derating-note-na.pdf i'I 30 version P/N:SUx H-USOOONNU4 c SolarEdge Technologies,Inc.All rights reserved.SOLAIREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks, ,-r,- r Technologies,�are trademarks of their respective owners,s . • air mmAo Air System designed with � All parts fit in a box for easy ` maximum versatility for any logistics arrays including staggered Drop-in features make the install process intuitive and fast 0 Simple design allows system to be installed by single installer U Listed to UL Standard 2703 for on the roof O Grounding/Bonding and Fire Classification SnapNrack RL Universal is designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the highest spansof any current rail less system. Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation *8 • Features a rock-in channel nut design for easy attachment to Flash Track IR • Slotted riser provides leveling for easy height adjustments 40 Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing row-to-row bonding • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules lt4 • Skirt length is compatible with both portrait and landscape module orientations Quality. Innovative . Superior, SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources • improve overall installationquality and . • '019 by SnapNrack Solar • SOlUtions.All rights reserved DESCRIPTION: 71 DRAWN BY:SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins SnapNrack Solar MountingSolutions REVISION: PART NUMBER(S): A 595 MARKET STREET,.-FLOOR.9AN 1--W.,CA-I-USA PHONE(415)580-6900•FAX(415)5WB902 242-02155 THE INFOR 1- IN THIS ORAWIRO IS OONFI OF lT L ANO PROPRIETARY.ANV REPROOUCAON,OIS0.-NCO OR USE THEREOF IS PROHIEITEO WITHOUT THE WRITTEN CONSENT SMMN SOUTH LLG 10 5 0 0 4 3 9 40 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X IIN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 i DESCRIPTION: DRAWN BY: n n SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins REVISION: Solar Mounting Solutions PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO CA 94105 USA PHONE(415)560-6900•FAX(415)560-6902 242-02155 THE INfORr ON IN THIS DRAWING IS CONFIDENTIAL•HI PROPRIETgRY.F REPRODUCTION.DISIL NCE.ORUSETIEAEOFISPROU-Q WITHp)T THE WRITTEN CON6ENT OF SUNRUN SOUiII LLL. 1.50 3.41 1.50 2.35 1.50 1.55 .66 -T- 1 2.00 1.24 1.00 SLOT �y 2.63� -1.50--� ALL DIMENSIONS IN INCHES